WorldWideScience

Sample records for preliminary dose estimates

  1. Preliminary estimation of minimum target dose in intracavitary radiotherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Oishi-Tanaka, Yumiko; Sugahara, Shinji; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2001-08-01

    In intracavitary radiotherapy (ICRT) for cervical cancer, minimum target dose (D{sub min}) will pertain to local disease control more directly than will reference point A dose (D{sub A}). However, ICRT has been performed traditionally without specifying D{sub min} since the target volume was not identified. We have estimated D{sub min} retrospectively by identifying tumors using magnetic resonance (MR) images. Pre- and posttreatment MR images of 31 patients treated with high-dose-rate ICRT were used. ICRT was performed once weekly at 6.0 Gy D{sub A}, and involved 2-5 insertions for each patient, 119 insertions in total. D{sub min} was calculated arbitrarily simply at the point A level using the tumor width (W{sub A}) to compare with D{sub A}. W{sub A} at each insertion was estimated by regression analysis with pre- and posttreatment W{sub A}. D{sub min} for each insertion varied from 3.0 to 46.0 Gy, a 16-fold difference. The ratio of total D{sub min} to total D{sub A} for each patient varied from 0.5 to 6.5. Intrapatient D{sub min} difference between the initial insertion and final insertion varied from 1.1 to 3.4. Preliminary estimation revealed that D{sub min} varies widely under generic dose prescription. Thorough D{sub min} specification will be realized when ICRT-applicator insertion is performed under MR imaging. (author)

  2. Preliminary liver dose estimation in the new facility for biomedical applications at the RA-3 reactor

    International Nuclear Information System (INIS)

    Gadan, M.; Crawley, V.; Thorp, S.; Miller, M.

    2009-01-01

    As a part of the project concerning the irradiation of a section of the human liver left lobe, a preliminary estimation of the expected dose was performed. To obtain proper input values for the calculation, neutron flux and gamma dose rate characterization were carried out using adequate portions of cow or pig liver covered with demineralized water simulating the preservation solution. Irradiations were done inside a container specially designed to fulfill temperature preservation of the organ and a reproducible irradiation position (which will be of importance for future planification purposes). Implantable rhodium based self-powered neutron detectors were developed to obtain neutron flux profiles both external and internal. Implantation of SPND was done along the central longitudinal axis of the samples, where lowest flux is expected. Gamma dose rate was obtained using a neutron shielded graphite ionization chamber moved along external surfaces of the samples. The internal neutron profile resulted uniform enough to allow for a single and static irradiation of the liver. For dose estimation, irradiation condition was set in order to obtain a maximum of 15 Gy-eq in healthy tissue. Additionally, literature reported boron concentrations of 47 ppm in tumor and 8 ppm in healthy tissue and a more conservative relationship (30/10 ppm) were used. To make a conservative estimation of the dose the following considerations were done: (i).Minimum measured neutron flux inside the sample (∼5x10 9 n cm -2 s -1 ) was considered to calculate dose in tumor. (ii).Maximum measured neutron flux (considering both internal as external profiles) was used to calculate dose in healthy tissue (∼8.7x10 9 n cm -2 s -1 ). (iii).Maximum measured gamma dose rate (∼13.5 Gy h -1 ) was considered for both tumor and healthy tissue. Tumor tissue dose was ∼69 Gy-eq for 47 ppm of 10 B and ∼42 Gy-eq for 30 ppm, for a maximum dose of 15 Gy-eq in healthy tissue. As can be seen from these results

  3. SU-E-T-86: A Systematic Method for GammaKnife SRS Fetal Dose Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Geneser, S; Paulsson, A; Sneed, P; Braunstein, S; Ma, L [UCSF Comprehensive Cancer Center, San Francisco, CA (United States)

    2015-06-15

    Purpose: Estimating fetal dose is critical to the decision-making process when radiation treatment is indicated during pregnancy. Fetal doses less than 5cGy confer no measurable non-cancer developmental risks but can produce a threefold increase in developing childhood cancer. In this study, we estimate fetal dose for a patient receiving Gamma Knife stereotactic radiosurgery (GKSRS) treatment and develop a method to estimate dose directly from plan details. Methods: A patient underwent GKSRS on a Perfexion unit for eight brain metastases (two infratentorial and one brainstem). Dose measurements were performed using a CC13, head phantom, and solid water. Superficial doses to the thyroid, sternum, and pelvis were measured using MOSFETs during treatment. Because the fetal dose was too low to accurately measure, we obtained measurements proximally to the isocenter, fitted to an exponential function, and extrapolated dose to the fundus of the uterus, uterine midpoint, and pubic synthesis for both the preliminary and delivered plans. Results: The R-squared fit for the delivered doses was 0.995. The estimated fetal doses for the 72 minute preliminary and 138 minute delivered plans range from 0.0014 to 0.028cGy and 0.07 to 0.38cGy, respectively. MOSFET readings during treatment were just above background for the thyroid and negligible for all inferior positions. The method for estimating fetal dose from plan shot information was within 0.2cGy of the measured values at 14cm cranial to the fetal location. Conclusion: Estimated fetal doses for both the preliminary and delivered plan were well below the 5cGy recommended limit. Due to Pefexion shielding, internal dose is primarily governed by attenuation and drops off exponentially. This is the first work that reports fetal dose for a GK Perfexion unit. Although multiple lesions were treated and the duration of treatment was long, the estimated fetal dose remained very low.

  4. SU-E-T-86: A Systematic Method for GammaKnife SRS Fetal Dose Estimation

    International Nuclear Information System (INIS)

    Geneser, S; Paulsson, A; Sneed, P; Braunstein, S; Ma, L

    2015-01-01

    Purpose: Estimating fetal dose is critical to the decision-making process when radiation treatment is indicated during pregnancy. Fetal doses less than 5cGy confer no measurable non-cancer developmental risks but can produce a threefold increase in developing childhood cancer. In this study, we estimate fetal dose for a patient receiving Gamma Knife stereotactic radiosurgery (GKSRS) treatment and develop a method to estimate dose directly from plan details. Methods: A patient underwent GKSRS on a Perfexion unit for eight brain metastases (two infratentorial and one brainstem). Dose measurements were performed using a CC13, head phantom, and solid water. Superficial doses to the thyroid, sternum, and pelvis were measured using MOSFETs during treatment. Because the fetal dose was too low to accurately measure, we obtained measurements proximally to the isocenter, fitted to an exponential function, and extrapolated dose to the fundus of the uterus, uterine midpoint, and pubic synthesis for both the preliminary and delivered plans. Results: The R-squared fit for the delivered doses was 0.995. The estimated fetal doses for the 72 minute preliminary and 138 minute delivered plans range from 0.0014 to 0.028cGy and 0.07 to 0.38cGy, respectively. MOSFET readings during treatment were just above background for the thyroid and negligible for all inferior positions. The method for estimating fetal dose from plan shot information was within 0.2cGy of the measured values at 14cm cranial to the fetal location. Conclusion: Estimated fetal doses for both the preliminary and delivered plan were well below the 5cGy recommended limit. Due to Pefexion shielding, internal dose is primarily governed by attenuation and drops off exponentially. This is the first work that reports fetal dose for a GK Perfexion unit. Although multiple lesions were treated and the duration of treatment was long, the estimated fetal dose remained very low

  5. Preliminary evaluation of lung doses for dogs exposed to 239PuO2

    International Nuclear Information System (INIS)

    Fisher, D.R.; Cannon, W.C.; Hadley, R.T.; Park, J.F.

    1986-01-01

    A group of beagle dogs exposed to inhaled 239 PuO 2 is being followed for life-span effects. This paper reports preliminary lung dose estimates and dose-response relationships for incidence of lung tumors and radiation pneumonitis which have been observed to date. Doses were estimated by using both conventional dose-averaging and microdosimetric techniques. Cascade impactor sampling data were used to reconstruct the original plutonium aerosol size distributions unique to each of about 120 individual dogs exposed to 239 PuO 2 . Data providing the initial plutonium lung burden and lifetime lung retention-clearance functions of plutonium for each dog were used for calculating average dose rates, cumulative absorbed doses, and specific energy distributions. A linear dose-response relationship for lung tumor induction was estimated on the basis of cumulative lung dose. Average time to death was estimated as a function of average dose rate. Conclusions regarding the potential value of microdosimetry in the interpretation of such dose-response relationships are discussed. 8 refs., 5 figs., 1 tab

  6. A new approach to the estimation of radiopharmaceutical radiation dose distributions

    International Nuclear Information System (INIS)

    Hetherington, E.L.R.; Wood, N.R.

    1975-03-01

    For a photon energy of 150 keV, the Monte Carlo technique of photon history simulation was used to obtain estimates of the dose distribution in a human phantom for three activity distributions relevant to diagnostic nuclear medicine. In this preliminary work, the number of photon histories considered was insufficient to produce complete dose contours and the dose distributions are presented in the form of colour-coded diagrams. The distribution obtained illustrate an important deficiency in the MIRD Schema for dose estimation. Although the Schema uses the same mathematical technique for calculating photon doses, the results are obtained as average values for the whole body and for complete organs. It is shown that the actual dose distributions, particularly those for the whole body may, differ significantly from the average value calculated using the MIRD Schema and published absorbed fractions. (author)

  7. Preliminary estimation of the dose rates of the operation room of the RPR radioisotope cell

    International Nuclear Information System (INIS)

    Rocha, A.C.S.; Silva, J.J.G.; Pina, J.L.S. de; Fajardo, P.W.

    1986-07-01

    During the preliminary studies, about the installations layout of a radioisotope production reactor, the possibility of construction of a radioisotope cell at the reactor building has been investigated. The decisions about that construction has considered mainly the level of the radiation dose over the cell operator. The dose rate has been calculated based on: neutron flux and gamma radiation from fission products and activation materials inside the reactor; volatile fission products such as noble gases and iodides; tritium form ternary fission. The objective was calculate the radiation dose over the cell operator during a journey of 8 hours of work per day. For those calculations some data have been obtained from the Angra-3 reactor. (author)

  8. Population dose and health impact of the accident at the Three Mile Island Nuclear Station. Preliminary estimates for the period March 28, 1979--April 7, 1979

    International Nuclear Information System (INIS)

    Battist, L.; Congel, F.; Buchanan, J.; Peterson, H.

    1979-05-01

    This report contains a preliminary assessment of the radiation dose and potential health impact of the accident on March 28, 1979 at the Three Mile Island Nuclear Station. This assessment was prepared by a task group composed of technical staff members from The Environmental Protection Agency, The Department of Health, Education and Welfare, and The Nuclear Regulatory Commission. The estimated dose that might have been received by an individual is less than 100 mrem. The collective dose received by the 2,164,000 people estimated to live within 50 miles of the reactor site is calculated to be 3,300 person-rem (with a range of 1600 to 5300 person-rem). This corresponds to an average dose of approximately 1.5 mrem. The potential number of fatal cancers that is projected to occur as a result of the accident is less than 1. This potential impact would be undetectable compared to the 325,000 cancer deaths that would normally be expected to occur in a population of 2,164,000. The estimated total health impact, including fatal and non-fatal cancers and genetic effects to all future generations is approximately 2 health effects

  9. Developing milk industry estimates for dose reconstruction projects

    International Nuclear Information System (INIS)

    Beck, D.M.; Darwin, R.F.

    1991-01-01

    One of the most important contributors to radiation doses from hanford during the 1944-1947 period was radioactive iodine. Consumption of milk from cows that ate vegetation contaminated with iodine is likely the dominant pathway of human exposure. To estimate the doses people could have received from this pathway, it is necessary to reconstruct the amount of milk consumed by people living near Hanford, the source of the milk, and the type of feed that the milk cows ate. This task is challenging because the dairy industry has undergone radical changes since the end of World War 2, and records that document the impact of these changes on the study area are scarce. Similar problems are faced by researchers on most dose reconstruction efforts. The purpose of this work is to document and evaluate the methods used on the Hanford Environmental Dose Reconstruction (HEDR) Project to reconstruct the milk industry and to present preliminary results

  10. Assessment of uncertainties of external dose estimation after the Chernobyl accident

    International Nuclear Information System (INIS)

    Kruk, Julianna

    2008-01-01

    Full text: In the remote period of time after the Chernobyl accident the estimation of an external exposure with using of direct dose rate measurements or individual monitoring of inhabitants is rationally only for settlements where the preliminary estimation makes the range equal or greater 1.0 mSv per year. For inhabitancies of settlements where the preliminary estimation makes the range less 1.0 mSv per year the external dose is correctly to estimate by calculation. For the last cases the uncertainty should be assessed. The most accessible initial parameter for calculation of a dose of an external exposure is the average ground deposition of Cs-137 for the settlements. The character of density distribution of Cs-137 deposition in an area of one settlement is well enough studied. The best agreement of distribution of this parameter is reached with log-normal distribution practically for all settlements of the investigated territories with factor of a variation 0.3-0.6 and the standard geometrical deviation lying within the limits of 1.4-1.7. The dose factors which correspond to the structure of an available housing of settlement (type of apartment houses: wooden, stone, multi-storey) and age structure of the population are bring the main contribution into uncertainty of the external dose estimation. The situations with a different level of known information have been considered for the estimation of influence of those parameters on the general uncertainty. Thus the estimation of the uncertainty of the external dose was done for two variant: optimistic and pessimistic. In the optimistic case the estimation of external doses will be spent for specific settlement with known structure of housing and according to a known share of the living population in houses of the certain type. In that case, variability value dose factor will be limited to the chosen type of a residential building (for example - the one-storied wooden house), and a share of the living population

  11. Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study

    International Nuclear Information System (INIS)

    Cho, S H

    2005-01-01

    A recent mice study demonstrated that gold nanoparticles could be safely administered and used to enhance the tumour dose during radiation therapy. The use of gold nanoparticles seems more promising than earlier methods because of the high atomic number of gold and because nanoparticles can more easily penetrate the tumour vasculature. However, to date, possible dose enhancement due to the use of gold nanoparticles has not been well quantified, especially for common radiation treatment situations. Therefore, the current preliminary study estimated this dose enhancement by Monte Carlo calculations for several phantom test cases representing radiation treatments with the following modalities: 140 kVp x-rays, 4 and 6 MV photon beams, and 192 Ir gamma rays. The current study considered three levels of gold concentration within the tumour, two of which are based on the aforementioned mice study, and assumed either no gold or a single gold concentration level outside the tumour. The dose enhancement over the tumour volume considered for the 140 kVp x-ray case can be at least a factor of 2 at an achievable gold concentration of 7 mg Au/g tumour assuming no gold outside the tumour. The tumour dose enhancement for the cases involving the 4 and 6 MV photon beams based on the same assumption ranged from about 1% to 7%, depending on the amount of gold within the tumour and photon beam qualities. For the 192 Ir cases, the dose enhancement within the tumour region ranged from 5% to 31%, depending on radial distance and gold concentration level within the tumour. For the 7 mg Au/g tumour cases, the loading of gold into surrounding normal tissue at 2 mg Au/g resulted in an increase in the normal tissue dose, up to 30%, negligible, and about 2% for the 140 kVp x-rays, 6 MV photon beam, and 192 Ir gamma rays, respectively, while the magnitude of dose enhancement within the tumour was essentially unchanged. (note)

  12. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  13. Radiation dose estimates for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Stabin, M.G.; Stubbs, J.B.; Toohey, R.E.

    1996-04-01

    Tables of radiation dose estimates based on the Cristy-Eckerman adult male phantom are provided for a number of radiopharmaceuticals commonly used in nuclear medicine. Radiation dose estimates are listed for all major source organs, and several other organs of interest. The dose estimates were calculated using the MIRD Technique as implemented in the MIRDOSE3 computer code, developed by the Oak Ridge Institute for Science and Education, Radiation Internal Dose Information Center. In this code, residence times for source organs are used with decay data from the MIRD Radionuclide Data and Decay Schemes to produce estimates of radiation dose to organs of standardized phantoms representing individuals of different ages. The adult male phantom of the Cristy-Eckerman phantom series is different from the MIRD 5, or Reference Man phantom in several aspects, the most important of which is the difference in the masses and absorbed fractions for the active (red) marrow. The absorbed fractions for flow energy photons striking the marrow are also different. Other minor differences exist, but are not likely to significantly affect dose estimates calculated with the two phantoms. Assumptions which support each of the dose estimates appears at the bottom of the table of estimates for a given radiopharmaceutical. In most cases, the model kinetics or organ residence times are explicitly given. The results presented here can easily be extended to include other radiopharmaceuticals or phantoms

  14. Preliminary estimates of dose and residual activation of selected components in ring collimation straight of the SNS

    International Nuclear Information System (INIS)

    Ludewig, H.; Catalan-Lasheras, N.; Simos, N.; Walker, J.; Mallen, A.; Wei, J.; Todosow, M.

    2000-01-01

    The highest doses to components in the SNS ring are expected to be to those located in the collimation straight section. In this paper the authors present estimated doses to magnets and cable located between collimators. In addition the buildup of relatively long half-life radioactive isotopes is estimated, following machine operation and shutdown. Finally, the potential dose to operators approaching the machine following operation and shutdown for four hours is made. The results indicate that selected components might require replacement after several years of full power operation. In addition, the reflection of gamma-rays from the tunnel walls contribute a non-negligible amount to the dose of an operator in the tunnel following machine shutdown

  15. Aspects of pre-dose and other luminescence phenomena in quartz absorbed dose estimation

    International Nuclear Information System (INIS)

    Adamiec, G.

    2000-01-01

    The understanding of all luminescence processes occurring in quartz is of paramount importance in the further development of robust absorbed dose estimation techniques (for the purpose of dating and retrospective dosimetry). The findings presented in this thesis, aid future improvements of absorbed dose estimation techniques using quartz by presenting investigations in the following areas: 1) interpretation of measurement results, 2) numerical modelling of luminescence in quartz, 3) phenomena needing inclusion in future physical models of luminescence. In the first part, the variability of properties of single quartz grains is examined. Through empirical and theoretical considerations, investigations are made of various problems of measurements of luminescence using multi-grain aliquots, and specifically areas where the heterogeneity of the sample at the inter-grain level may be misinterpreted at the multi-grain-aliquot level. The results obtained suggest that the heterogeneity of samples is often overlooked, and that such differences can have a profound influence on the interpretation of measurement results. Discussed are the shape of TL glow curves, OSL decay curves, dose response curves (including consequences for using certain signals as proxies for others), normalisation procedures and D E estimation techniques. Further, a numerical model of luminescence is proposed, which includes multiple R-centres and is used to describe the pre-dose sensitisation in quartz. The numerical model exhibits a broad-scale behaviour observed experimentally in a sample of annealed quartz. The shapes of TAC for lower (20 Gy) and higher doses (1 kGy) and the evolution with temperature of the isothermal sensitisation curves are qualitatively matched for the empirical and numerical systems. In the third area, a preliminary investigation of the properties of the '110 deg. C peak' in the 550 nm emission band, in annealed quartz is presented. These properties are in sharp contrast with

  16. On Preliminary Test Estimator for Median

    OpenAIRE

    Okazaki, Takeo; 岡崎, 威生

    1990-01-01

    The purpose of the present paper is to discuss about estimation of median with a preliminary test. Two procedures are presented, one uses Median test and the other uses Wilcoxon two-sample test for the preliminary test. Sections 3 and 4 give mathematical formulations of such properties, including mean square errors with one specified case. Section 5 discusses their optimal significance levels of the preliminary test and proposes their numerical values by Monte Carlo method. In addition to mea...

  17. Weldon Spring historical dose estimate

    International Nuclear Information System (INIS)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr

  18. Weldon Spring historical dose estimate

    Energy Technology Data Exchange (ETDEWEB)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr.

  19. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S P [Forskningscente Risoe, Roskilde (Denmark); Iosjpe, M; Strand, P [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1995-09-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Barents and Kara Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario which ignores the presence of barriers between spent nuclear fuel and seawater is estimated to give rise to about 10 mansieverts calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide {sup 137}Cs is found to dominate the doses. (au) 8 tabs., 56 ills., 19 refs.

  20. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic sea

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Iosjpe, M.; Strand, P.

    1995-11-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Kara and Barents Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario, which ignores the presence of barriers between spent nuclear fuel and seawater, is estimated to give rise to about 10 mansievert calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide 137 Cs is found to dominate the doses. 19 refs., 56 figs., 8 tabs

  1. A preliminary assessment of potential doses to man from radioactive waste dumped in the Arctic Sea

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Iosjpe, M.; Strand, P.

    1995-09-01

    This report describes a preliminary radiological assessment of collective doses to the world population from radioactive material dumped in the Barents and Kara Seas in the period 1961-1991. Information on the dumped waste and the rates of release of radionuclides have been available from Russian sources and from the International Atomic Energy Agency. A box model has been used to simulate the dispersion of radionuclides in the marine environment and to calculate the contamination of seafood and the subsequent radiation doses to man. Two release scenarios have been adopted. The worst-case release scenario which ignores the presence of barriers between spent nuclear fuel and seawater is estimated to give rise to about 10 mansieverts calculated to 1000 years from the time of release. A more realistic release scenario is estimated to cause about 3 mansieverts. In both cases exposure from the radionuclide 137 Cs is found to dominate the doses. (au) 8 tabs., 56 ills., 19 refs

  2. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  3. The MIRD method of estimating absorbed dose

    International Nuclear Information System (INIS)

    Weber, D.A.

    1991-01-01

    The estimate of absorbed radiation dose from internal emitters provides the information required to assess the radiation risk associated with the administration of radiopharmaceuticals for medical applications. The MIRD (Medical Internal Radiation Dose) system of dose calculation provides a systematic approach to combining the biologic distribution data and clearance data of radiopharmaceuticals and the physical properties of radionuclides to obtain dose estimates. This tutorial presents a review of the MIRD schema, the derivation of the equations used to calculate absorbed dose, and shows how the MIRD schema can be applied to estimate dose from radiopharmaceuticals used in nuclear medicine

  4. Estimation of thyroid doses received by the population of Belarus as a result of the Chernobyl accident

    International Nuclear Information System (INIS)

    Gavrilin, Yu.; Khrouch, V.; Shinkarev, S.; Drozdovitch, V.; Minenko, V.; Shemyakina, E.; Bouville, A.; Anspaugh, L.

    1996-01-01

    Within weeks of the Chernobyl accident, about 300000 measurements of human thyroidal 131 I content were conducted in the more contaminated territories of the Republic of Belarus. Results of these and other measurements form the basis of thyroid-dose reconstruction for residents of Belarus. Preliminary estimates of thyroid doses have been divided into three classes. Class 1 ('measured' doses). Individual doses are estimated directly from the measured thyroidal 131 I content of the person considered, plus information on life style and dietary habits. Such estimates are available for about 130000 individuals from the contaminated areas of Gomel and Mogilev Region and Minsk city. Class 2 ('passport' doses). For every settlement with a sufficient number of residents with 'measured' doses, individual thyroid-dose distributions are determined for several age groups and levels of milk consumption. This action has been called the 'passportization' of the settlement. A population of about 2.7 million people resides in the 'passportized' settlements. Class 3 ('inferred' doses). For any settlement where the number of residents with 'measured' doses is small or equal to zero, individual thyroid doses are derived from the relationship obtained between the mean adult-thyroid dose and the deposition density of 131 I or 137 Cs in settlements with 'passport' doses presenting characteristics similar to those of the settlement considered. This method can be applied to the remainder of the population (about 7.3 million people). An approximate estimate of the collective thyroid dose for the residents of Belarus is presented. Illustrative results of individual thyroid dose and associated uncertainty are discussed for rural settlements and urban areas

  5. Estimated radiation dose from timepieces containing tritium

    International Nuclear Information System (INIS)

    McDowell-Boyer, L.M.

    1980-01-01

    Luminescent timepieces containing radioactive tritium, either in elemental form or incorporated into paint, are available to the general public. The purpose of this study was to estimate potential radiation dose commitments received by the public annually as a result of exposure to tritium which may escape from the timepieces during their distribution, use, repair, and disposal. Much uncertainty is associated with final dose estimates due to limitations of empirical data from which exposure parameters were derived. Maximum individual dose estimates were generally less than 3 μSv/yr, but ranged up to 2 mSv under worst-case conditions postulated. Estimated annual collective (population) doses were less than 5 person/Sv per million timepieces distributed

  6. Validation of dose-response curve of CRCN-NE - Regional Center for Nuclear Sciences from Northeast Brazil for 60Co: preliminary results

    International Nuclear Information System (INIS)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Hwang, Suy F.; Lima, Fabiana F.; Santos, Neide

    2014-01-01

    The cytogenetic study has the chromosomal alterations as biomarkers in absorbed dose estimation by the body of individuals involved in exposure to ionizing radiation by interpreting a dose response calibration curve. Since the development of the technique to the analysis of data, you can see protocol characteristics, leading the International Atomic Energy Agency indicate that any laboratory with intention to carry out biological dosimetry establish their own calibration curves. The Biological Dosimetry Laboratory of the Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN), Brazil, recently established the calibration curve related to gamma radiation ( 60 Co). Thus, this work aimed to start the validation of this calibration curve from samples of three different blood donors which were irradiated with an absorbed known single dose of 1 Gy. Samples were exposed to 60 Co source (Glaucoma 220) located in the Department of Nuclear Energy (DEN/UFPE). After fixation with methanol and acetic acid and 5% Giemsa staining, the frequency of chromosomal alterations (dicentric chromosomes, acentric rings and fragments) were established from reading of 500 metaphases per sample and doses were estimated using Dose Estimate program. The results showed that, using the dose-response curve calibration for dicentrics, the dose absorbed estimated for the three individuals ranged from 0.891 - 1,089Gy, taking into account the range of confidence of 95%. By using the dose-response curve for dicentrics added to rings and for the same interval of confidence the doses ranged from 0,849 - 1,081Gy. Thus, the estimative encompassed known absorbed dose the three individuals in confidence interval of 95%. These preliminary results seems to demonstrate that dicentric dose-response curves and dicentrics plus rings established by CRCN-NE / CNEN are valid for dose estimation in exposed individuals. This validation will continue with samples from different individuals at different doses

  7. Preliminary characterization of dose in personnel of interventional radiology

    International Nuclear Information System (INIS)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle

    2016-01-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  8. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  9. A preliminary assessment of individual doses in the environs of Berkeley, Gloucestershire, following the Chernobyl nuclear reactor accident

    International Nuclear Information System (INIS)

    Nair, S.; Darley, P.J.

    1986-06-01

    A preliminary assessment has been made of the individual doses to critical group members of the public in the environs of Berkeley arising from fallout resulting from the Chernobyl accident. The assessment was based on measurements of airborne radionuclide concentrations, ground deposition and nuclide concentrations in rainwater, tapwater, grass, milk and green vegetables. The committed effective dose-equivalent was found to be as follows:- Adult - 200 μSv, 1 year old child - 500 μSv, the 10 year old child receiving a dose intermediate between these two values. The estimate accounts only for the nuclides measured and the specific exposure routes considered namely ingestion of milk and vegetables, inhalation and external exposure. However, it is believed that the inclusion of a range of other nuclides of potential significance, which may have been present but not measured, and potential intakes from additional routes is unlikely to increase the above estimates by more than a factor of 2. (author)

  10. Phase 1 of the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    1991-08-01

    The work described in this report was prompted by the public's concern about potential effect from the radioactive materials released from the Hanford Site. The Hanford Environmental Dose Reconstruction (HEDR) Project was established to estimate radiation dose the public might have received from the Hanford Site since 1944, when facilities began operating. Phase 1 of the HEDR Project is a ''pilot'' or ''demonstration'' phase. The objectives of this initial phase were to determine whether enough historical information could be found or reconstructed to be used for dose estimation and develop and test conceptual and computational models for calculating credible dose estimates. Preliminary estimates of radiation doses were produced in Phase 1 because they are needed to achieve these objectives. The reader is cautioned that the dose estimates provided in this and other Phase 1 HEDR reports are preliminary. As the HEDR Project continues, the dose estimates will change for at least three reasons: more complete input information for models will be developed; the models themselves will be refined; and the size and shape of the geographic study area will change. This is one of three draft reports that summarize the first phase of the four-phased HEDR Project. This, the Summary Report, is directed to readers who want a general understanding of the Phase 1 work and preliminary dose estimates. The two other reports -- the Air Pathway Report and the Columbia River Pathway Report -- are for readers who understand the radiation dose assessment process and want to see more technical detail. Detailed descriptions of the dose reconstruction process are available in more than 20 supporting reports listed in Appendix A. 32 refs., 46 figs

  11. Estimation of dose from chromosome aberration rate

    International Nuclear Information System (INIS)

    Li Deping

    1990-01-01

    The methods and skills of evaluating dose from correctly scored shromsome aberration rate are presented, and supplemented with corresponding BASIC computer code. The possibility and preventive measures of excessive probability of missing score of the aberrations in some of the current routine score methods are discussed. The use of dose-effect relationship with exposure time correction factor G in evaluating doses and their confidence intervals, dose estimation in mixed n-γ exposure, and identification of high by nonuniform acute exposure to low LET radiation and its dose estimation are discussed in more detail. The difference of estimated dose due to whether the interaction between subleisoms produced by n and γ have been taken into account is examined. In fitting the standard dose-aberration rate curve, proper weighing of experiment points and comparison with commonly accepted values are emphasised, and the coefficient of variation σ y √y of the aberration rate y as a function of dose and exposure time is given. In appendix I and II, the dose-aberration rate formula is derived from dual action theory, and the time variation of subleisom is illustrated and in appendix III, the estimation of dose from scores of two different types of aberrations (of other related score) is illustrated. Two computer codes are given in appendix IV, one is a simple code, the other a complete code, including the fitting of standard curve. the skills of using compressed data storage, and the production of simulated 'data ' for testing the curve fitting procedure are also given

  12. Fetus dose estimate of a pregnant worker

    International Nuclear Information System (INIS)

    Castro, P.; Espana, M.L.; Sevillano, D.; Minguez, C.; Ferrer, C.; Lopez Franco, P.

    2006-01-01

    A female employee working in diagnostic radiology should take additional controls to protect the unborn child from ionizing radiations. The fetus is particularly sensitive to the effects of x-rays and, so, the determination of the equivalent dose to the unborn child is of interest for risk estimates from occupational exposures of the pregnant workers. The ian of this study is to develop a method for fetus dose estimate of a pregnant worker who participates in interventional radiology procedures. Factors for converting dosemeter readings to equivalent dose to the fetus have been measured using thermoluminescence dosimetry. Equivalent dose to the uterus is used to simulate the equivalent dose to the fetus during the first two months of pregnancy. Measurements at different depths are made to consider the variations in the position of the uterus between pregnant women. The normalized doses obtained are dependent on the beam quality. Accurate estimation of fetus doses due to occupational exposures can be made using the data provided in the current study. (Author)

  13. Estimation of population dose from all sources in Japan

    International Nuclear Information System (INIS)

    Kusama, Tomoko; Nakagawa, Takeo; Kai, Michiaki; Yoshizawa, Yasuo

    1988-01-01

    The purposes of estimation of population doses are to understand the per-caput doses of the public member from each artificial radiation source and to determine the proportion contributed of the doses from each individual source to the total irradiated population. We divided the population doses into two categories: individual-related and source-related population doses. The individual-related population dose is estimated based on the maximum assumption for use in allocation of the dose limits for members of the public. The source-related population dose is estimated both to justify the sources and practices and to optimize radiation protection. The source-related population dose, therefore, should be estimated as realistically as possible. We investigated all sources that caused exposure to the population in Japan from the above points of view

  14. A preliminary examination of audience-related communications issues for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, C.W.

    1991-04-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project will estimate radiation doses people may have received from exposure to radioactive materials released during past operations at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. The HEDR Project was initiated in response to public concerns about possible health impacts from past releases of radioactive materials from Hanford. The TSP recognized early in the project that special mechanisms would be required to effectively communicate to the many different concerned audiences. Accordingly, the TSP directed PNL to examine methods for communicating causes and effects of uncertainties in the dose estimates. After considering the directive and discussing it with the Communications Subcommittee of the TSP, PNL undertook a broad investigation of communications methods to consider for inclusion in the TSP's current communications program. As part of this investigation, a literature review was conducted regarding risk communications. A key finding was that, in order to successfully communicate risk-related information, a thorough understanding of the knowledge level, concerns and information needs of the intended recipients (i.e., the audience) is necessary. Hence, a preliminary audience analysis was conducted as part of the present research. This report summarizes the results of this analysis. 1 ref., 9 tabs.

  15. Early estimates of UK radiation doses from the Chernobyl reactor

    International Nuclear Information System (INIS)

    Fry, F.A.; Clarke, R.H.; O'Riordan, M.C.

    1986-01-01

    The plume of radioactive material from the Chernobyl reactor accident passed over the United Kingdom and will increase the radiation dose to the population in the coming year. The increase above the normal annual dose from natural radiation, averaged over persons of all ages, will be about 15% in the north and 1% in the south of the country. Averaged over all ages and areas, the increase will be about 4%. This excess dose will decrease substantially in subsequent years. The accident at the nuclear power station in Chernobyl, near Kiev, on or after 26 April 1986, led to substantial quantities of radioactive material being released to the atmosphere. Wind initially transported the material towards northern and western Europe. Activity was first detected in the southern United Kingdom, some ∼ 2,000 km away, on 2 May. The National Radiological Protection Board (NRPB), the operators of nuclear installations and the regulating authorities, had anticipated this eventuality and had intensified their normal programmes of environmental monitoring. During the following days many measurements were made and a considerable amount of data was generated throughout the country. NRPB was assigned responsibility for collating and evaluating these results; the initial information is used here to make a preliminary estimate of the radiation doses to the population of the United Kingdom

  16. Preliminary dose assessment of the Chernobyl accident

    International Nuclear Information System (INIS)

    Hull, A.P.

    1987-01-01

    From the major accident at Unit 4 of the Chernobyl nuclear power station, a plume of airborne radioactive fission products was initially carried northwesterly toward Poland, thence toward Scandinavia and into Central Europe. Reports of the levels of radioactivity in a variety of media and of external radiation levels were collected in the Department of Energy's Emergency Operations Center and compiled into a data bank. Portions of these and other data which were obtained directly from published and official reports were utilized to make a preliminary assessment of the extent and magnitude of the external dose to individuals downwind from Chernobyl. Radioactive 131 I was the predominant fission product. The time of arrival of the plume and the maximum concentrations of 131 I in air, vegetation and milk and the maximum reported depositions and external radiation levels have been tabulated country by country. A large amount of the total activity in the release was apparently carried to a significant elevation. The data suggest that in areas where rainfall occurred, deposition levels were from ten to one-hundred times those observed in nearby ''dry'' locations. Sufficient spectral data were obtained to establish average release fractions and to establish a reference spectra of the other nuclides in the release. Preliminary calculations indicated that the collective dose equivalent to the population in Scandinavia and Central Europe during the first year after the Chernobyl accident would be about 8 x 10 6 person-rem. From the Soviet report, it appears that a first year population dose of about 2 x 10 7 person-rem (2 x 10 5 Sv) will be received by the population who were downwind of Chernobyl within the U.S.S.R. during the accident and its subsequent releases over the following week. 32 refs., 14 figs., 20 tabs

  17. Preliminary radiological consequence estimates for a reference LEU core for PARR

    International Nuclear Information System (INIS)

    Ali Khan, L.

    1990-01-01

    Radiological consequence analysis of a reference LEU core for Pakistan Research Reactor (PARR) has been carried out using mathematical models. It was assumed that 20% of the fuel, having an average burn-up of 50% achieved by continuously operating the reactor for 300 days at 10 MW, fails. It was further assumed that 100% of the noble gases and a fraction of iodine are released. Three modes of leakage from reactor building have been considered. These are exhaust through the normal ventilation system, through emergency ventilation system and leakage from the building. The whole body and thyroid doses have been calculated for 2 hours and 30 days at the boundaries of the exclusion zone at 450m and the low population zone at 1000m. For the releases at stack height through normal and emergency ventilation system, doses at both the boundaries remain within emergency dose limits of 300 rem for thyroid and 25 rem for the whole body. However, in the case of direct release from the containment building, the limiting thyroid dose of 300 rem, at 1000m, for 30 days exposure is achieved for a leak rate of 27% per day under Pasquill condition E. The results presented in this report are only preliminary estimates. A more accurate detailed analysis for various burnups will be carried out using standard computer codes

  18. Recommendations to the Technical Steering Panel regarding approach for estimating individual radiation doses resulting from releases of radionuclides to the Columbia River

    International Nuclear Information System (INIS)

    Napier, B.A.; Brothers, A.J.

    1992-07-01

    At the direction of the Technical Steering Panel (TSP) of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle staff have reviewed and analyzed available data regarding possible historical radiation doses to individuals resulting from radionuclide releases to the Columbia River. The objective of this review was to recommend to the TSP the spatial and temporal scope and level of effort on Columbia River work to most effectively extend work performed in Phase I of the project (PNL 1991a, PNL 1991b) to meet the project objectives. A number of options were analyzed. Four stretches of the Columbia River and adjacent Pacific coastal waters were defined and investigated for four time periods. Radiation doses arising from ten potentially major exposure pathways were evaluated for each of the time/location combinations, and several alternative methods were defined for estimating the doses from each pathway. Preliminary cost estimates were also developed for implementing dose estimation activities for each of the possible combinations

  19. Integration of models for the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Napier, B.A.

    1991-01-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation dose that individuals could have received as a result of emissions from nuclear operations at Hanford since 1944. The objective of phase 1 of the project was to demonstrate through calculations that adequate models and support data exist or could be developed to allow realistic estimations of doses to individuals from releases of radionuclides to the environment that occurred as long as 45 years ago. Much of the data used in phase 1 was preliminary; therefore, the doses calculated must be considered preliminary approximations. This paper describes the integration of various models that was implemented for initial computer calculations. Models were required for estimating the quantity of radioactive material released, for evaluating its transport through the environment, for estimating human exposure, and for evaluating resultant doses

  20. Preliminary uncertainty analysis for the doses estimated using the Techa River dosimetry system - 2000

    International Nuclear Information System (INIS)

    Napier, Bruce A.; Shagina, N B.; Degteva, M O.; Tolstykh, E I.; Vorobiova, M I.; Anspaugh, L R.

    2000-01-01

    The Mayak Production Association (MPA) was the first facility in the former Soviet Union for the production of plutonium. As a result of failures in the technological processes in the late 1940's and early 1950's, members of the public were exposed via discharge of about 1017 Bq of liquid wastes into the Techa River (1949-1956). Residents of many villages downstream on the Techa River were exposed via a variety of pathways; the more significant included drinking of water from the river and external gamma exposure due to proximity to sediments and shoreline. The specific aim of this project is to enhance the reconstruction of external and internal radiation doses for individuals in the Extended Techa River Cohort. The purpose of this paper is to present the approaches being used to evaluate the uncertainty in the calculated individual doses and to provide example and representative results of the uncertainty analyses. The magnitude of the uncertainties varies depending on location and time of individual exposure, but the results from reference-individual calculations indicate that for external doses, the range of uncertainty is about factors of four to five. For internal doses, the range of uncertainty depends on village of residence, which is actually a surrogate for source of drinking water. For villages with single sources of drinking water (river or well), the ratio of the 97.5th percentile-to 2.5th percentile estimates can be a factor of 20 to 30. For villages with mixed sources of drinking water (river and well), the ratio of the range can be over two orders of magnitude

  1. Occupational dose estimates for a monitored retrievable storage facility

    International Nuclear Information System (INIS)

    Harty, R.; Stoetzel, G.A.

    1986-06-01

    Occupational doses were estimated for radiation workers at the monitored retrievable storage (MRS) facility. This study provides an estimate of the occupational dose based on the current MRS facility design, examines the extent that various design parameters and assumptions affect the dose estimates, and identifies the areas and activities where exposures can be reduced most effectively. Occupational doses were estimated for both the primary storage concept and the alternate storage concept. The dose estimates indicate the annual dose to all radiation workers will be below the 5 rem/yr federal dose equivalent limit. However, the estimated dose to most of the receiving and storage crew (the workers responsible for the receipt, storage, and surveillance of the spent fuel and its subsequent retrieval), to the crane maintenance technicians, and to the cold and remote maintenance technicians is above the design objective of 1 rem/yr. The highest annual dose is received by the riggers (4.7 rem) in the receiving and storage crew. An indication of the extent to which various design parameters and assumptions affect the dose estimates was obtained by changing various design-based assumptions such as work procedures, background dose rates in radiation zones, and the amount of fuel received and stored annually. The study indicated that a combination of remote operations, increased shielding, and additional personnel (for specific jobs) or changes in operating procedures will be necessary to reduce worker doses below 1.0 rem/yr. Operations that could be made at least partially remote include the removal and replacement of the tiedowns, impact limiters, and personnel barriers from the shipping casks and the removal or installation of the inner closure bolts. Reductions of the background dose rates in the receiving/shipping and the transfer/discharge areas may be accomplished with additional shielding

  2. Transmission dose estimation algorithm for in vivo dosimetry

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Shin, Kyo Chul; Huh, Soon Nyung; Woo, Hong Gyun; Ha, Sung Whan; Lee, Hyoung Koo

    2002-01-01

    Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with an acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed for estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ±0.5%. For elongated radiation field, the errors were limited to ±1.0%. The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings

  3. Transmission dose estimation algorithm for in vivo dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun; Shin, Kyo Chul [Dankook Univ., Seoul (Korea, Republic of); Huh, Soon Nyung; Woo, Hong Gyun; Ha, Sung Whan [Seoul National Univ., Seoul (Korea, Republic of); Lee, Hyoung Koo [Catholic Univ., Seoul (Korea, Republic of)

    2002-07-01

    Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with an acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed for estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within {+-}0.5%. For elongated radiation field, the errors were limited to {+-}1.0%. The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.

  4. Validation of dose-response curve of CRCN-NE - Regional Center for Nuclear Sciences from Northeast Brazil for {sup 60}Co: preliminary results; Validacao da curva dose-resposta do CRCN-NE para {sup 60}Co: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Julyanne C.G.; Mendes, Mariana E.; Hwang, Suy F.; Lima, Fabiana F. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Santos, Neide, E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (CCB/UFPE), Recife, PE (Brazil). Departamento de Genetica

    2014-07-01

    The cytogenetic study has the chromosomal alterations as biomarkers in absorbed dose estimation by the body of individuals involved in exposure to ionizing radiation by interpreting a dose response calibration curve. Since the development of the technique to the analysis of data, you can see protocol characteristics, leading the International Atomic Energy Agency indicate that any laboratory with intention to carry out biological dosimetry establish their own calibration curves. The Biological Dosimetry Laboratory of the Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN), Brazil, recently established the calibration curve related to gamma radiation ({sup 60}Co). Thus, this work aimed to start the validation of this calibration curve from samples of three different blood donors which were irradiated with an absorbed known single dose of 1 Gy. Samples were exposed to {sup 60}Co source (Glaucoma 220) located in the Department of Nuclear Energy (DEN/UFPE). After fixation with methanol and acetic acid and 5% Giemsa staining, the frequency of chromosomal alterations (dicentric chromosomes, acentric rings and fragments) were established from reading of 500 metaphases per sample and doses were estimated using Dose Estimate program. The results showed that, using the dose-response curve calibration for dicentrics, the dose absorbed estimated for the three individuals ranged from 0.891 - 1,089Gy, taking into account the range of confidence of 95%. By using the dose-response curve for dicentrics added to rings and for the same interval of confidence the doses ranged from 0,849 - 1,081Gy. Thus, the estimative encompassed known absorbed dose the three individuals in confidence interval of 95%. These preliminary results seems to demonstrate that dicentric dose-response curves and dicentrics plus rings established by CRCN-NE / CNEN are valid for dose estimation in exposed individuals. This validation will continue with samples from different individuals at different doses.

  5. Considerations on absorbed dose estimates based on different β-dose point kernels in internal dosimetry

    International Nuclear Information System (INIS)

    Uchida, Isao; Yamada, Yasuhiko; Yamashita, Takashi; Okigaki, Shigeyasu; Oyamada, Hiyoshimaru; Ito, Akira.

    1995-01-01

    In radiotherapy with radiopharmaceuticals, more accurate estimates of the three-dimensional (3-D) distribution of absorbed dose is important in specifying the activity to be administered to patients to deliver a prescribed absorbed dose to target volumes without exceeding the toxicity limit of normal tissues in the body. A calculation algorithm for the purpose has already been developed by the authors. An accurate 3-D distribution of absorbed dose based on the algorithm is given by convolution of the 3-D dose matrix for a unit cubic voxel containing unit cumulated activity, which is obtained by transforming a dose point kernel into a 3-D cubic dose matrix, with the 3-D cumulated activity distribution given by the same voxel size. However, beta-dose point kernels affecting accurate estimates of the 3-D absorbed dose distribution have been different among the investigators. The purpose of this study is to elucidate how different beta-dose point kernels in water influence on the estimates of the absorbed dose distribution due to the dose point kernel convolution method by the authors. Computer simulations were performed using the MIRD thyroid and lung phantoms under assumption of uniform activity distribution of 32 P. Using beta-dose point kernels derived from Monte Carlo simulations (EGS-4 or ACCEPT computer code), the differences among their point kernels gave little differences for the mean and maximum absorbed dose estimates for the MIRD phantoms used. In the estimates of mean and maximum absorbed doses calculated using different cubic voxel sizes (4x4x4 mm and 8x8x8 mm) for the MIRD thyroid phantom, the maximum absorbed doses for the 4x4x4 mm-voxel were estimated approximately 7% greater than the cases of the 8x8x8 mm-voxel. They were found in every beta-dose point kernel used in this study. On the other hand, the percentage difference of the mean absorbed doses in the both voxel sizes for each beta-dose point kernel was less than approximately 0.6%. (author)

  6. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  7. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  8. Preliminary cost estimating for the nuclear industry

    International Nuclear Information System (INIS)

    Klumpar, I.V.; Soltz, K.M.

    1985-01-01

    The nuclear industry has higher costs for personnel, equipment, construction, and engineering than conventional industry, which means that cost estimation procedures may need adjustment. The authors account for the special technical and labor requirements of the nuclear industry in making adjustments to equipment and installation cost estimations. Using illustrative examples, they show that conventional methods of preliminary cost estimation are flexible enough for application to emerging industries if their cost structure is similar to that of the process industries. If not, modifications can provide enough engineering and cost data for a statistical analysis. 9 references, 14 figures, 4 tables

  9. Fast skin dose estimation system for interventional radiology.

    Science.gov (United States)

    Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru

    2018-03-01

    To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.

  10. CY 1995 radiation dose reconciliation report and resulting CY 1996 dose estimate for the 324 nuclear facility

    International Nuclear Information System (INIS)

    Landsman, S.D.; Thornhill, R.E.; Peterson, C.A.

    1996-04-01

    In this report, the dose estimate for CY 1995 is reconciled by month wih actual doses received. Results of the reconciliation were used to revise estimates of worker dose for CY 1996. Resulting dose estimate for the facility is also included. Support for two major programs (B-Cell Cleanout and Surveillance and Maintenance) accounts for most of the exposure received by workers in the faility. Most of the expousre received by workers comes from work in the Radiochemical Engineering Complex airlock. In spite of schedule and work scope changes during CY 1995, dose estimates were close to actual exposures received. A number of ALARA measures were taken throughout the year; exposure reduction due to those was 20.6 Man-Rem, a 28% reduction from the CY 1995 estimate. Baseline estimates for various tasks in the facility were used to compile the CY 1996 dose estimate of 45.4 Man-Rem; facility goal for CY 1996 is to reduce worker dose by 20%, to 36.3 Man-Rem

  11. Dose estimation from residual and fallout radioactivity, 1

    International Nuclear Information System (INIS)

    Takeshita, Kenji

    1975-01-01

    External dose rates and cumulative doses for early entrants from areal surveys and simulated experiments are reviewed. The average cumulative doses to infinity at the hypocenters were 101 rad in Hiroshima and 32 rad in Nagasaki, with a variation of about 60 percent. Radioactive fallout areas nearly matched the ''black rain'' areas in Nagasaki and in Hiroshima. Radioactivity in the fallout areas was affected by radioactive decay and by the leaching and dissipation by rains. Considering these factors, the cumulative dose to infinity in the fallout area of Hiroshima was estimated to be 13 rad, excluding internal radiation doses from inhaled and ingested radionuclides. Attempts to estimate radiation dose from internally deposited radionuclides are also described. (auth.)

  12. beta. and. gamma. -comparative dose estimates on Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L. (California Univ., Livermore (USA). Lawrence Livermore National Lab.)

    1982-05-01

    Enewetak Atoll in the Pacific is used for atmospheric testing of U.S. nuclear weapons. Beta dose and ..gamma..-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the ..beta.. and low energy ..gamma..-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a ..beta..-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to ..beta..- or low energy ..gamma..-contribution. The contribution at any particular site, however, is reduced by vegetation. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey. Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the ..beta..'s or low energy ..gamma..'s, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  13. Ingestion of Nevada Test Site Fallout: Internal dose estimates

    International Nuclear Information System (INIS)

    Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1996-01-01

    This paper summarizes individual and collective dose estimates for the internal organs of hypothetical yet representative residents of selected communities that received measurable fallout from nuclear detonations at the Nevada Test Site. The doses, which resulted from ingestion of local and regional food products contaminated with over 20 radionuclides, were estimated with use of the PATHWAY food-chain-transport model to provide estimates of central tendency and uncertainty. The thyroid gland received much higher doses than other internal organs and tissues. In a avery few cases, infants might have received thyroid doses in excess of 1 Gy, depending on location, diet, and timing of fallout. 131 I was the primary thyroid dose contributor, and fresh milk was the main exposure pathway. With the exception of the thyroid, organ doses from the ingestion pathway were much smaller (<3%) than those from external gamma exposure to deposited fallout. Doses to residents living closest to the Nevada Test Site were contributed mainly by a few fallout events; doses to more distantly located people were generally smaller, but a greater number of events provided measurable contributions. The effectiveness of different fallout events in producing internal organ doses through ingestion varied dramatically with seasonal timing of the test, with maximum dose per unit fallout occurring for early summer depositions when milk cows were on pasture and fresh, local vegetables were used. Within specific communities, internal doses differed by age, sex, and lifestyle. Collective internal dose estimates for specific geographic areas are provided

  14. Maximum likelihood estimation for cytogenetic dose-response curves

    International Nuclear Information System (INIS)

    Frome, E.L.; DuFrain, R.J.

    1986-01-01

    In vitro dose-response curves are used to describe the relation between chromosome aberrations and radiation dose for human lymphocytes. The lymphocytes are exposed to low-LET radiation, and the resulting dicentric chromosome aberrations follow the Poisson distribution. The expected yield depends on both the magnitude and the temporal distribution of the dose. A general dose-response model that describes this relation has been presented by Kellerer and Rossi (1972, Current Topics on Radiation Research Quarterly 8, 85-158; 1978, Radiation Research 75, 471-488) using the theory of dual radiation action. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting dose-time-response models are intrinsically nonlinear in the parameters. A general-purpose maximum likelihood estimation procedure is described, and estimation for the nonlinear models is illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure

  15. Bayesian estimation of dose rate effectiveness

    International Nuclear Information System (INIS)

    Arnish, J.J.; Groer, P.G.

    2000-01-01

    A Bayesian statistical method was used to quantify the effectiveness of high dose rate 137 Cs gamma radiation at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice. The Bayesian approach considers both the temporal and dose dependence of radiation carcinogenesis and total mortality. This paper provides the first direct estimation of dose rate effectiveness using Bayesian statistics. This statistical approach provides a quantitative description of the uncertainty of the factor characterising the dose rate in terms of a probability density function. The results show that a fixed dose from 137 Cs gamma radiation delivered at a high dose rate is more effective at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice than the same dose delivered at a low dose rate. (author)

  16. Preliminary analysis of public dose from CFETR gaseous tritium release

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Baojie [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); University of Science and Technology of China, Hefei, Anhui 230027 (China); Ni, Muyi, E-mail: muyi.ni@fds.org.cn [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Lian, Chao; Jiang, Jieqiong [Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2015-02-15

    Highlights: • Present the amounts and limit dose of tritium release to the environment for CFETR. • Perform a preliminary simulation of radiation dose for gaseous tritium release. • Key parameters about soil types, wind speed, stability class, effective release height and age were sensitivity analyzed. • Tritium release amount is recalculated consistently with dose limit in Chinese regulation for CFETR. - Abstract: To demonstrate tritium self-sufficiency and other engineering issues, the scientific conception of Chinese Fusion Engineering Test Reactor (CFETR) has been proposed in China parallel with ITER and before DEMO reactor. Tritium environmental safety for CFETR is an important issue and must be evaluated because of the huge amounts of tritium cycling in reactor. In this work, different tritium release scenarios of CFETR and dose limit regulations in China are introduced. And the public dose is preliminarily analyzed under normal and accidental events. Furthermore, after finishing the sensitivity analysis of key input parameters, the public dose is reevaluated based on extreme parameters. Finally, tritium release amount is recalculated consistently with the dose limit in Chinese regulation for CFETR, which would provide a reference for tritium system design of CFETR.

  17. Nonparametric estimation of benchmark doses in environmental risk assessment

    Science.gov (United States)

    Piegorsch, Walter W.; Xiong, Hui; Bhattacharya, Rabi N.; Lin, Lizhen

    2013-01-01

    Summary An important statistical objective in environmental risk analysis is estimation of minimum exposure levels, called benchmark doses (BMDs), that induce a pre-specified benchmark response in a dose-response experiment. In such settings, representations of the risk are traditionally based on a parametric dose-response model. It is a well-known concern, however, that if the chosen parametric form is misspecified, inaccurate and possibly unsafe low-dose inferences can result. We apply a nonparametric approach for calculating benchmark doses, based on an isotonic regression method for dose-response estimation with quantal-response data (Bhattacharya and Kong, 2007). We determine the large-sample properties of the estimator, develop bootstrap-based confidence limits on the BMDs, and explore the confidence limits’ small-sample properties via a short simulation study. An example from cancer risk assessment illustrates the calculations. PMID:23914133

  18. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  19. Preliminary characterization of dose in personnel of interventional radiology; Caracterizacao preliminar da dose em profissionais de radiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Godolfim, Laura Larre; Anes, Mauricio; Bacelar, Alexandre; Lykawka, Rochelle [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil)

    2016-07-01

    Exposure to X-rays of Interventional Radiology professionals (IR) impacts in the high dose rate received by these individuals, and there are reports of biological effects of this professional activity. Therefore, it is fomented greater control over the doses received by these workers. This research intends to characterize the doses received by the professionals during IR procedures. We evaluated the doses of radiologists, anesthesiologists and nursing staff of the Hospital de Clinicas de Porto Alegre, through measures with dosimeters of the OSL type, distributed in up to six regions of the body of these professionals. Until now were accompanied 33 cholangiography procedures and 29 embolization procedures. As a preliminary result, it was possible to identify a wide variation between doses of the professionals of the same function in each procedure. In overview, the dose of the professionals presented in descending order as a radiologist 1> radiologist 2 > anesthetist > nursing. (author)

  20. A Web-Based System for Bayesian Benchmark Dose Estimation.

    Science.gov (United States)

    Shao, Kan; Shapiro, Andrew J

    2018-01-11

    Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.

  1. Dose Estimation from Daily and Weekly Dosimetry Data

    International Nuclear Information System (INIS)

    Ostrouchov, G.

    2001-01-01

    Statistical analyses of data from epidemiologic studies of workers exposed to radiation have been based on recorded annual radiation doses (yearly dose of record). It is usually assumed that the dose values are known exactly, although it is generally recognized that the data contain uncertainty due to measurement error and bias. In our previous work with weekly data, a probability distribution was used to describe an individual's dose during a specific period of time and statistical methods were developed for estimating it from weekly film dosimetry data. This study showed that the yearly dose of record systematically underestimates doses for Oak Ridge National Laboratory (ORNL) workers. This could result in biased estimates of dose-response coefficients and their standard errors. The results of this evaluation raise serious questions about the suitability of the yearly dose of record for direct use in low-dose studies of nuclear industry workers. Here, we extend our previous work to use full information in Pocket meter data and develop the Data Synthesis for Individual Dose Estimation (DSIDE) methodology. Although the DSIDE methodology in this study is developed in the context of daily and weekly data to produce a cumulative yearly dose estimate, in principle it is completely general and can be extended to other time period and measurement combinations. The new methodology takes into account the ''measurement error'' that is produced by the film and pocket-meter dosimetry systems, the biases introduced by policies that lead to recording left-censored doses as zeros, and other measurement and recording practices. The DSIDE method is applied to a sample of dose histories obtained from hard copy dosimetry records at ORNL for the years 1945 to 1955. First, the rigorous addition of daily pocket-meter information shows that the negative bias is generally more severe than was reported in our work based on weekly film data only, however, the amount of bias also varies

  2. Dose Estimation from Daily and Weekly Dosimetry Data

    Energy Technology Data Exchange (ETDEWEB)

    Ostrouchov, G.

    2001-11-16

    Statistical analyses of data from epidemiologic studies of workers exposed to radiation have been based on recorded annual radiation doses (yearly dose of record). It is usually assumed that the dose values are known exactly, although it is generally recognized that the data contain uncertainty due to measurement error and bias. In our previous work with weekly data, a probability distribution was used to describe an individual's dose during a specific period of time and statistical methods were developed for estimating it from weekly film dosimetry data. This study showed that the yearly dose of record systematically underestimates doses for Oak Ridge National Laboratory (ORNL) workers. This could result in biased estimates of dose-response coefficients and their standard errors. The results of this evaluation raise serious questions about the suitability of the yearly dose of record for direct use in low-dose studies of nuclear industry workers. Here, we extend our previous work to use full information in Pocket meter data and develop the Data Synthesis for Individual Dose Estimation (DSIDE) methodology. Although the DSIDE methodology in this study is developed in the context of daily and weekly data to produce a cumulative yearly dose estimate, in principle it is completely general and can be extended to other time period and measurement combinations. The new methodology takes into account the ''measurement error'' that is produced by the film and pocket-meter dosimetry systems, the biases introduced by policies that lead to recording left-censored doses as zeros, and other measurement and recording practices. The DSIDE method is applied to a sample of dose histories obtained from hard copy dosimetry records at ORNL for the years 1945 to 1955. First, the rigorous addition of daily pocket-meter information shows that the negative bias is generally more severe than was reported in our work based on weekly film data only, however, the

  3. Estimates of bias and uncertainty in recorded external dose

    International Nuclear Information System (INIS)

    Fix, J.J.; Gilbert, E.S.; Baumgartner, W.V.

    1994-10-01

    A study is underway to develop an approach to quantify bias and uncertainty in recorded dose estimates for workers at the Hanford Site based on personnel dosimeter results. This paper focuses on selected experimental studies conducted to better define response characteristics of Hanford dosimeters. The study is more extensive than the experimental studies presented in this paper and includes detailed consideration and evaluation of other sources of bias and uncertainty. Hanford worker dose estimates are used in epidemiologic studies of nuclear workers. A major objective of these studies is to provide a direct assessment of the carcinogenic risk of exposure to ionizing radiation at low doses and dose rates. Considerations of bias and uncertainty in the recorded dose estimates are important in the conduct of this work. The method developed for use with Hanford workers can be considered an elaboration of the approach used to quantify bias and uncertainty in estimated doses for personnel exposed to radiation as a result of atmospheric testing of nuclear weapons between 1945 and 1962. This approach was first developed by a National Research Council (NRC) committee examining uncertainty in recorded film badge doses during atmospheric tests (NRC 1989). It involved quantifying both bias and uncertainty from three sources (i.e., laboratory, radiological, and environmental) and then combining them to obtain an overall assessment. Sources of uncertainty have been evaluated for each of three specific Hanford dosimetry systems (i.e., the Hanford two-element film dosimeter, 1944-1956; the Hanford multi-element film dosimeter, 1957-1971; and the Hanford multi-element TLD, 1972-1993) used to estimate personnel dose throughout the history of Hanford operations. Laboratory, radiological, and environmental sources of bias and uncertainty have been estimated based on historical documentation and, for angular response, on selected laboratory measurements

  4. beta- and gamma-Comparative dose estimates on Eniwetok Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L.

    1982-05-01

    Eniwetok Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Eniwetok Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  5. Automated dose estimation for lost or damaged dosimeters

    International Nuclear Information System (INIS)

    Thompson, W.L.; Deininger, R.J.

    1988-01-01

    This paper reports that some dosimetry vendors will compute doses for their customers' lost/damaged dosimeters based upon an average of recent dosimeter readings. However, the vendors usually require authorization from the customer for each such occurrence. Therefore, the tedious task of keeping track of the overdue status of each missing dosimeter and constantly notifying the vendor is still present. Also, depending on the monthly variability of a given person's doses, it may be more valid to use the employee's average dose, his/her highest dose over a recent period, an average dose of other employees with similar job duties for that period, or the maximum permissible dose. Thus, the task of estimating doses for lost/damaged dosimeters cannot be delegated to dosimetry vendor. Instead, the radiation safety department must sue the data supplied by the vendor as input for performing estimates. The process is performed automatically at the Medical Center Hospital of Vermont using a personal computer and a relational database

  6. Convolution-based estimation of organ dose in tube current modulated CT

    Science.gov (United States)

    Tian, Xiaoyu; Segars, W. Paul; Dixon, Robert L.; Samei, Ehsan

    2016-05-01

    Estimating organ dose for clinical patients requires accurate modeling of the patient anatomy and the dose field of the CT exam. The modeling of patient anatomy can be achieved using a library of representative computational phantoms (Samei et al 2014 Pediatr. Radiol. 44 460-7). The modeling of the dose field can be challenging for CT exams performed with a tube current modulation (TCM) technique. The purpose of this work was to effectively model the dose field for TCM exams using a convolution-based method. A framework was further proposed for prospective and retrospective organ dose estimation in clinical practice. The study included 60 adult patients (age range: 18-70 years, weight range: 60-180 kg). Patient-specific computational phantoms were generated based on patient CT image datasets. A previously validated Monte Carlo simulation program was used to model a clinical CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). A practical strategy was developed to achieve real-time organ dose estimation for a given clinical patient. CTDIvol-normalized organ dose coefficients ({{h}\\text{Organ}} ) under constant tube current were estimated and modeled as a function of patient size. Each clinical patient in the library was optimally matched to another computational phantom to obtain a representation of organ location/distribution. The patient organ distribution was convolved with a dose distribution profile to generate {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} values that quantified the regional dose field for each organ. The organ dose was estimated by multiplying {{≤ft(\\text{CTD}{{\\text{I}}\\text{vol}}\\right)}\\text{organ, \\text{convolution}}} with the organ dose coefficients ({{h}\\text{Organ}} ). To validate the accuracy of this dose estimation technique, the organ dose of the original clinical patient was estimated using Monte Carlo program with TCM profiles explicitly modeled. The

  7. Estimation of environmental transfer of plutonium and the dose to man

    International Nuclear Information System (INIS)

    1981-09-01

    The need to examine the behaviour of individual radionuclides in the environment is stressed. Sometimes unique pathways of exposure exist and more specialized methods of dose estimation could be considered. The toxicity of the alpha emitting plutonium isotopes is of concern and their long half-lives lead to persistence in the environment and long-term potential for exposing man. Some formulas are therefore presented for making preliminary estimates of environmental transfer and dose for the radioisotopes of the element plutonium. Exposure of man to plutonium in the environment may occur by inhalation or ingestion - the inhalation and ingestion intake rates for which specific pathways have been considered are listed. The primary pathway to man is the inhalation intake; the most important ingestion intake is the consumption of plant foods due to the greater concentration achieved and the higher consumption rates of these foods. Also discussed is plutonium in the nuclear fuel cycle, the release of plutonium from current nuclear installations, the occurrence of plutonium from weapons fallout, airborne releases of plutonium (concentration in the air, deposition rate, resuspension, transfer to plants - foliar and root uptake - transfer to milk, etc.), liquid release (concentration in water, transfer to drinking water, to fish, to plants by irrigation, to milk, to meat). The importance of the release situation and local environment conditions including land and water utilization, population factors and habits for any further investigation is pointed out

  8. Estimation of 18FDG doses's cost

    International Nuclear Information System (INIS)

    Hamza, Fatma; Amouri, W.; Jardak, I.; Kallel, F.; Charfeddine, S.; Guermazi, F.

    2013-01-01

    The cyclotron facility, essentially for medical use, is far from being a simple establishment of a dedicated device to accelerate particles producing a beta plus emitter radioelement. The cyclotron site encompasses more over all necessary equipments for the production and the quality control of considered radiotracer that 18 FDG is just one example. This facility is subject to strict standards in terms of radiopharmaceutical production, radiation level, pressure level and airflow resulting in the production of a drug submitted to the MA (Marketing Authorization). These multiple factors directly influence the final cost of the dose that remains to be reachable by the patient. The aim of this work is to estimate the cost of a dose of 18 FDG to ensure financial viability of the project while accessible to the patient. The cost of the facility will entail the following: buildings and utilities, equipment and operational cost. This calculation is possible only if we define in advance the type of cyclotron, which is bound to the market needs in particular the number of PET facilities, the number of scans per day and the radioactive decay of radioelement. Our study represents a simulation that considers some hypothesis. We assumed that the cyclotron is installed in Sousse and that the PET facilities number (positon emission tomography) is 6 in which 4 are located 2 hours away. For a PET scan, the average dose per patient is about 350 MBq (5 MBq/kg) and the exam duration is about 45 minutes. Each center performs 10 tests per day. In terms of fees, we considered device and building's cost, facility amortization, consumables (target, marking accessories), maintenance, remuneration expense and the annual electricity consumption. All our calculations have been reported to the number of working days per year. The estimates were made outside the customs duties and technical assistance that may last up to 2 years. Requirements and needs were estimated at 5.4 curies per day. For

  9. The estimation of occupational effective dose in diagnostic radiology with two dosimeters

    International Nuclear Information System (INIS)

    Niklason, L.T.; Marx, M.V.; Chan, Heang-Ping

    1994-01-01

    Annual effective dose limits have been proposed by national and international radiation protection committees. Radiation protection agencies must decide upon a method of converting the radiation dose measured from dosimeters to an estimate of effective dose. A proposed method for the estimation of effective dose from the radiation dose to two dosimeters is presented. Correction factors are applied to an over-apron collar dose and an under-apron dose to estimate the effective dose. Correction factors are suggested for two cases, both with and without a thyroid shield. Effective dose may be estimated by the under-apron dose plus 6% of the over-collar dose if a thyroid shield is not worn or plus 2% of the over-collar dose if a thyroid shield is worn. This method provides a reasonable estimate of effective dose that is independent of lead apron thickness and accounts for the use of a thyroid shield. 17 refs., 3 tabs

  10. Preliminary design studies for the DESCARTES and CIDER codes

    International Nuclear Information System (INIS)

    Eslinger, P.W.; Miley, T.B.; Ouderkirk, S.J.; Nichols, W.E.

    1992-12-01

    The Hanford Environmental Dose Reconstruction (HEDR) project is developing several computer codes to model the release and transport of radionuclides into the environment. This preliminary design addresses two of these codes: Dynamic Estimates of Concentrations and Radionuclides in Terrestrial Environments (DESCARTES) and Calculation of Individual Doses from Environmental Radionuclides (CIDER). The DESCARTES code will be used to estimate the concentration of radionuclides in environmental pathways, given the output of the air transport code HATCHET. The CIDER code will use information provided by DESCARTES to estimate the dose received by an individual. This document reports on preliminary design work performed by the code development team to determine if the requirements could be met for Descartes and CIDER. The document contains three major sections: (i) a data flow diagram and discussion for DESCARTES, (ii) a data flow diagram and discussion for CIDER, and (iii) a series of brief statements regarding the design approach required to address each code requirement

  11. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  12. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  13. Dose estimates in Japan following the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Togawa, Orihiko; Homma, Toshimitsu; Iijima, Toshinori; Midorikawa, Yuji.

    1988-02-01

    Estimates have been made of the maximum individual doses and the collective doses in Japan following the Chernobyl reactor accident. Based on the measured data of ground deposition and radionuclide concentrations in air, raw milk, milk on sale and leafy vegetables, the doses from some significant radionuclides were calculated for 5 typical exposure pathways; cloudshine, groundshine, inhalation, ingestion of milk and leafy vegetables. The maximum effective dose equivalents for hypothetical individuals were calculated to be 1.8 mrem for adults, 3.7 mrem for children and 6.0 mrem for infants. The collective effective dose equivalent in Japan was estimated to be 5.8 x 10 4 man · rem; 0.50 mrem of the average dose per capita. (author)

  14. Monte Carlo estimation of the absorbed dose in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woo; Youn, Han Bean; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The purpose of this study is to devise an algorithm calculating absorbed dose distributions of patients based on Monte Carlo (MC) methods, and which includes the dose estimations due to primary and secondary (scattered) x-ray photons. Assessment of patient dose in computed tomography (CT) at the population level has become a subject of public attention and concern, and ultimate CT quality assurance and dose optimization have the goal of reducing radiation-induced cancer risks in the examined population. However, the conventional CT dose index (CTDI) concept is not a surrogate of risk but it has rather been designed to measure an average central dose. In addition, the CTDI or the dose-length product has showed troubles for helical CT with a wider beam collimation. Simple algorithms to estimate a patient specific CT dose based on the MCNP output data have been introduced. For numerical chest and head phantoms, the spatial dose distributions were calculated. The results were reasonable. The estimated dose distribution map can be readily converted into the effective dose. The important list for further studies includes the validation of the models with the experimental measurements and the acceleration of algorithms.

  15. Recommendations to the Technical Steering Panel regarding approach for estimating individual radiation doses resulting from releases of radionuclides to the Columbia River

    International Nuclear Information System (INIS)

    Brothers, A.J.; Napier, B.A.

    1992-08-01

    At the direction of the Technical Steering Panel (TSP) of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle staff have reviewed and analyzed available data regarding possible historical radiation doses to individuals resulting from radionuclide releases to the Columbia River. The objective of this review was to recommend to the TSP the spatial and temporal scope and level of effort on Columbia River work to most effectively extend work performed in Phase I of the project to meet the project objectives. Four stretches of the Columbia River and adjacent Pacific coastal waters were defined and investigated for four time periods. Radiation doses arising from ten potentially major exposure pathways were evaluated for each of the time/location combinations, and several alternative methods were defined for estimating the doses from each pathway. Preliminary cost estimates were also developed for implementing dose estimation activities for each of the possible combinations. The number of combinations of the alternatives is obviously very large. A ''value of information'' (VOI) decision analysis tool was developed and applied to the problem of selecting a few ''optimal'' sets of alternatives to consider. This VOI analysis relies on both available data and the judgement of technical experts. Input data and the algorithms used are described

  16. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children

    International Nuclear Information System (INIS)

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-01-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children. (orig.)

  17. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A. [Department of Radiological Sciences, St Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States); Mirro, Amy E. [Department of Biomedical Engineering, Washington University, St Louis, Missouri 63130 (United States)

    2014-07-15

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. The CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to

  18. Radiation doses estimation for hypothetical NPP Krsko accidents without and with PCFV using RASCAL software

    International Nuclear Information System (INIS)

    Vukovic, Josip; Konjarek, Damir; Grgic, Davor

    2014-01-01

    Calculation is done using Source Term to Dose module of RASCAL (Radiological Assessment System Consequence Analysis) software to estimate projected radiation doses from a radioactive plume to the environment. Utilizing this module, it is possible to do preliminary assessment of consequences to the environment in case of adverse reactor conditions or releases from other objects containing radioactive materials before the emergency situation has happened or in the early phase. RASCAL is simple, easy to use, fast-running tool able to provide initial estimate of radiological consequences of nuclear accidents. Upon entering rather limited amount of input parameters for the Krsko NPP, mostly key plant parameters, time dependent source term calculation is executed to determine radioactive inventory release rates for different plant conditions, release paths and availability of protective measures. These rates given for each radionuclide as a function of time are used as an input to atmospheric dispersion and transport model. Together with release rates, meteorological conditions dataset serve as input to determine the behavior of the radioactive releases that is plume in the atmosphere. So as an output, RASCAL produces a 'dispersion envelope' of radionuclide concentrations in the atmosphere. These concentrations of radionuclides in the atmosphere are further used for estimating the doses to the environment and the public downwind the release point. Throughout this paper, dose assessment is performed for two distances, close-in distance and distance out to 40 km from the source, for hypothetical NPP Krsko accidents without and with Passive Containment Filtered Vent (PCFV) system used. Obvious difference is related to released radioactivity of Iodine isotopes. Results of radioactive effluents deposition in the environment are displayed via various doze parameters, radionuclide concentrations and materials exposure rates in this particular case. (authors)

  19. New risk estimates at low doses

    International Nuclear Information System (INIS)

    Fry, R.J.M.

    1992-01-01

    The age of molecular radiation epidemiology may be at hand. The techniques are available to establish with the degree of precision required to determine whether agent-specific mutations can be identified consistently. A concerted effort to examine radiation-induced changes in as many relevant genes as possible appears to be justified. Cancers in those exposed to low doses of ionizing radiation should be chosen for the investigation. Parallel studies of radiation-induced cancers in experimental animals would not only complement the human studies, but perhaps reveal approaches to extrapolation of risk estimates across species. A caveat should be added to this optimistic view of what molecular studies might contribute to the knotty problem of risk estimates at low doses. The suggestions are made by one with no expertise in the field of molecular biology

  20. Mutation frequencies in male mice and the estimation of genetic hazards of radiation in men: (specific-locus mutations/dose-rate effect/doubling dose/risk estimation)

    International Nuclear Information System (INIS)

    Russell, W.L.; Kelly, E.M.

    1982-01-01

    Estimation of the genetic hazards of ionizing radiation in men is based largely on the frequency of transmitted specific-locus mutations induced in mouse spermatogonial stem cells at low radiation dose rates. The publication of new data on this subject has permitted a fresh review of all the information available. The data continue to show no discrepancy from the interpretation that, although mutation frequency decreases markedly as dose rate is decreased from 90 to 0.8 R/min (1 R = 2.6 X 10 -4 coulombs/kg) there seems to be no further change below 0.8 R/min over the range from that dose rate to 0.0007 R/min. Simple mathematical models are used to compute: (a) a maximum likelihood estimate of the induced mutation frequency at the low dose rates, and (b) a maximum likelihood estimate of the ratio of this to the mutation frequency at high dose rates in the range of 72 to 90 R/min. In the application of these results to the estimation of genetic hazards of radiation in man, the former value can be used to calculate a doubling dose - i.e., the dose of radiation that induces a mutation frequency equal to the spontaneous frequency. The doubling dose based on the low-dose-rate data compiled here is 110 R. The ratio of the mutation frequency at low dose rate to that at high dose rate is useful when it becomes necessary to extrapolate from experimental determinations, or from human data, at high dose rates to the expected risk at low dose rates. The ratio derived from the present analysis is 0.33

  1. Dose estimation in embryo or fetus in external fields

    International Nuclear Information System (INIS)

    Gregori, Beatriz N.

    2001-01-01

    The embryo or the fetus can be irradiated as result of radiological procedures of diagnosis of therapy in where the beam effects directly on the same one or in tissues or peripherical organs. Some authors have suggested that in the first stages of the pregnancy the dose in ovaries can be the good estimated of the dose in embryo or fetus. In advanced conditions of the development, probably also in the early stage, is more appropriated to specify the dose in the embryo or fetus equal of the uterus. The dose in the uterus is a good estimated so much for external irradiation as for radionuclides incorporation

  2. Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures

    International Nuclear Information System (INIS)

    Pereira, M. F.; Alves, J. G.; Sarmento, S.; Santos, J. A. M.; Sousa, M. J.; Gouvea, M.; Oliveira, A. D.; Cardoso, J. V.; Santos, L. M.

    2011-01-01

    A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The H p (10) dose values received above the lead apron (ranged 0.20-0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. H p (0.07) values to the hand (ranged 36.30-0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy. (authors)

  3. Anticoagulation and high dose liver radiation. A preliminary report

    International Nuclear Information System (INIS)

    Lightdale, C.J.; Wasser, J.; Coleman, M.; Brower, M.; Tefft, M.; Pasmantier, M.

    1979-01-01

    Two groups of patients were observed for evidence of acute radiation hepatitis during high dose radiation to the liver. The first group of 18 patients with metastatic liver disease received an average of 4,050 rad to the whole liver. Half received anticoagulation with warfarin. One patient on anticoagulation developed evidence of acute radiation hepatitis while 2 patients did so without anticoagulation. Eleven patients with Hodgkin's disease received 4,000 rad to the left lobe of the liver during extended field radiation. Four of these 11 patients were anticoagulated to therapeutic range. Only one of the fully anticoagulated patients showed changes on liver scan consistent with radiation hepatitis whereas three did so without anticoagulation. No serious sequelae from anticoagulation occurred in either group. These preliminary data suggest that anticoagulation may be safely administered with high dose hepatic radiation and that further trials with anticoagulation are warranted

  4. A novel approach for estimating ingested dose associated with paracetamol overdose.

    Science.gov (United States)

    Zurlinden, Todd J; Heard, Kennon; Reisfeld, Brad

    2016-04-01

    In cases of paracetamol (acetaminophen, APAP) overdose, an accurate estimate of tissue-specific paracetamol pharmacokinetics (PK) and ingested dose can offer health care providers important information for the individualized treatment and follow-up of affected patients. Here a novel methodology is presented to make such estimates using a standard serum paracetamol measurement and a computational framework. The core component of the computational framework was a physiologically-based pharmacokinetic (PBPK) model developed and evaluated using an extensive set of human PK data. Bayesian inference was used for parameter and dose estimation, allowing the incorporation of inter-study variability, and facilitating the calculation of uncertainty in model outputs. Simulations of paracetamol time course concentrations in the blood were in close agreement with experimental data under a wide range of dosing conditions. Also, predictions of administered dose showed good agreement with a large collection of clinical and emergency setting PK data over a broad dose range. In addition to dose estimation, the platform was applied for the determination of optimal blood sampling times for dose reconstruction and quantitation of the potential role of paracetamol conjugate measurement on dose estimation. Current therapies for paracetamol overdose rely on a generic methodology involving the use of a clinical nomogram. By using the computational framework developed in this study, serum sample data, and the individual patient's anthropometric and physiological information, personalized serum and liver pharmacokinetic profiles and dose estimate could be generated to help inform an individualized overdose treatment and follow-up plan. © 2015 The British Pharmacological Society.

  5. Maximum likelihood estimation for cytogenetic dose-response curves

    International Nuclear Information System (INIS)

    Frome, E.L; DuFrain, R.J.

    1983-10-01

    In vitro dose-response curves are used to describe the relation between the yield of dicentric chromosome aberrations and radiation dose for human lymphocytes. The dicentric yields follow the Poisson distribution, and the expected yield depends on both the magnitude and the temporal distribution of the dose for low LET radiation. A general dose-response model that describes this relation has been obtained by Kellerer and Rossi using the theory of dual radiation action. The yield of elementary lesions is kappa[γd + g(t, tau)d 2 ], where t is the time and d is dose. The coefficient of the d 2 term is determined by the recovery function and the temporal mode of irradiation. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting models are intrinsically nonlinear in the parameters. A general purpose maximum likelihood estimation procedure is described and illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure

  6. Maximum likelihood estimation for cytogenetic dose-response curves

    Energy Technology Data Exchange (ETDEWEB)

    Frome, E.L; DuFrain, R.J.

    1983-10-01

    In vitro dose-response curves are used to describe the relation between the yield of dicentric chromosome aberrations and radiation dose for human lymphocytes. The dicentric yields follow the Poisson distribution, and the expected yield depends on both the magnitude and the temporal distribution of the dose for low LET radiation. A general dose-response model that describes this relation has been obtained by Kellerer and Rossi using the theory of dual radiation action. The yield of elementary lesions is kappa(..gamma..d + g(t, tau)d/sup 2/), where t is the time and d is dose. The coefficient of the d/sup 2/ term is determined by the recovery function and the temporal mode of irradiation. Two special cases of practical interest are split-dose and continuous exposure experiments, and the resulting models are intrinsically nonlinear in the parameters. A general purpose maximum likelihood estimation procedure is described and illustrated with numerical examples from both experimental designs. Poisson regression analysis is used for estimation, hypothesis testing, and regression diagnostics. Results are discussed in the context of exposure assessment procedures for both acute and chronic human radiation exposure.

  7. Dose-response relationships and risk estimates for the induction of cancer due to low doses of low-LET radiation

    International Nuclear Information System (INIS)

    Elaguppillai, V.

    1981-01-01

    Risk estimates for radiation-induced cancer at low doses can be obtained only by extrapolation from the known effects at high doses and high dose rates, using a suitable dose-response model. The applicability of three different models, linear, sublinear and supralinear, are discussed in this paper. Several experimental studies tend to favour a sublinear dose-response model (linear-quadratic model) for low-LET radiation. However, human epidemiological studies do not exclude any of the dose-response relationships. The risk estimates based on linear and linear quadratic dose-response models are compared and it is concluded that, for low-LET radiation, the linear dose-response model would probably over-estimate the actual risk of cancer by a factor of two or more. (author)

  8. Dosing of cytotoxic chemotherapy: impact of renal function estimates on dose.

    Science.gov (United States)

    Dooley, M J; Poole, S G; Rischin, D

    2013-11-01

    Oncology clinicians are now routinely provided with an estimated glomerular filtration rate on pathology reports whenever serum creatinine is requested. The utility of using this for the dose determination of renally excreted drugs compared with other existing methods is needed to inform practice. Renal function was determined by [Tc(99m)]DTPA clearance in adult patients presenting for chemotherapy. Renal function was calculated using the 4-variable Modification of Diet in Renal Disease (4v-MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI), Cockcroft and Gault (CG), Wright and Martin formulae. Doses for renal excreted cytotoxic drugs, including carboplatin, were calculated. The concordance of the renal function estimates according to the CKD classification with measured Tc(99m)DPTA clearance in 455 adults (median age 64.0 years: range 17-87 years) for the 4v-MDRD, CKD-EPI, CG, Martin and Wright formulae was 47.7%, 56.3%, 46.2%, 56.5% and 60.2%, respectively. Concordance for chemotherapy dose for these formulae was 89.0%, 89.5%, 85.1%, 89.9% and 89.9%, respectively. Concordance for carboplatin dose specifically was 66.4%, 71.4%, 64.0%, 73.8% and 73.2%. All bedside formulae provide similar levels of concordance in dosage selection for the renal excreted chemotherapy drugs when compared with the use of a direct measure of renal function.

  9. Photon dose estimation from ultraintense laser–solid interactions and shielding calculation with Monte Carlo simulation

    International Nuclear Information System (INIS)

    Yang, Bo; Qiu, Rui; Li, JunLi; Lu, Wei; Wu, Zhen; Li, Chunyan

    2017-01-01

    When a strong laser beam irradiates a solid target, a hot plasma is produced and high-energy electrons are usually generated (the so-called “hot electrons”). These energetic electrons subsequently generate hard X-rays in the solid target through the Bremsstrahlung process. To date, only limited studies have been conducted on this laser-induced radiological protection issue. In this study, extensive literature reviews on the physics and properties of hot electrons have been conducted. On the basis of these information, the photon dose generated by the interaction between hot electrons and a solid target was simulated with the Monte Carlo code FLUKA. With some reasonable assumptions, the calculated dose can be regarded as the upper boundary of the experimental results over the laser intensity ranging from 10 19 to 10 21 W/cm 2 . Furthermore, an equation to estimate the photon dose generated from ultraintense laser–solid interactions based on the normalized laser intensity is derived. The shielding effects of common materials including concrete and lead were also studied for the laser-driven X-ray source. The dose transmission curves and tenth-value layers (TVLs) in concrete and lead were calculated through Monte Carlo simulations. These results could be used to perform a preliminary and fast radiation safety assessment for the X-rays generated from ultraintense laser–solid interactions. - Highlights: • The laser–driven X-ray ionizing radiation source was analyzed in this study. • An equation to estimate the photon dose based on the laser intensity is given. • The shielding effects of concrete and lead were studied for this new X-ray source. • The aim of this study is to analyze and mitigate the laser–driven X-ray hazard.

  10. Reaction of the hematopoietic system under long-term emotional stress developed after preliminary gamma-irradiation with low doses

    International Nuclear Information System (INIS)

    Moroz, B.B.; Deshevoj, Yu.B.; Lebedev, V.G.; Lyrshchikova, A.V.; Vorotnikova, T.V.

    1997-01-01

    In experiments on rats and mice it was shown that the preliminary protected gamma-irradiation with cumulative dose of 0.9 Gy (dose rate - 0.03 Gy/day) or single short-term gamma-irradiation with dose of 0.9 Gy (dose rate - 1.61 Gy/min) inhibited development of adaptive reactions and compensatory abilities of the hematopoietic system under long-term emotional stress

  11. Methodology for Estimating Ingestion Dose for Emergency Response at SRS

    CERN Document Server

    Simpkins, A A

    2002-01-01

    At the Savannah River Site (SRS), emergency response models estimate dose for inhalation and ground shine pathways. A methodology has been developed to incorporate ingestion doses into the emergency response models. The methodology follows a two-phase approach. The first phase estimates site-specific derived response levels (DRLs) which can be compared with predicted ground-level concentrations to determine if intervention is needed to protect the public. This phase uses accepted methods with little deviation from recommended guidance. The second phase uses site-specific data to estimate a 'best estimate' dose to offsite individuals from ingestion of foodstuffs. While this method deviates from recommended guidance, it is technically defensibly and more realistic. As guidance is updated, these methods also will need to be updated.

  12. Preliminary design review report for K Basin Dose Reduction Project

    International Nuclear Information System (INIS)

    Blackburn, L.D.

    1996-01-01

    The strategy for reducing radiation dose, originating from radionuclides absorbed in the K East Basin concrete, is to raise the pool water level to provide additional shielding. This report documents a preliminary design review conducted to ensure that design approaches for cleaning/coating basin walls and modifying other basin components were appropriate. The conclusion of this review was that design documents presently conclusion of this review was that design documents presently completed or in process of modification are and acceptable basis for proceeding to complete the design

  13. Dose estimation of the THOR BNCT treatment room

    International Nuclear Information System (INIS)

    Hsu, F.Y.; Liu, H.M.; Yu, C.C.; Huang, Y.H.; Tsai, H.N.

    2006-01-01

    BNCT beam of Tsing Hua Open-pool Reactor (THOR) was designed and constructed since 1998. A treatment room for the newly modified THOR BNCT beam was constructed for the next clinical-stage trials in 2004. Dose distribution in a patient (or a phantom) is important as irradiated with the BNCT beam. The dose distributions for different type of radiations such as neutron and photons in the treatment room are strongly becoming the index or reference of success for a BNCT facility. An ART head phantom was placed in front of the THOR BNCT beam port and was irradiated. In each section of the head phantom, numbers of small holes are inside and separated uniformly. Dual detector: TLD-600 and TLD-700 chips were placed inside these holes within the phantom to distinct doses of neutron and photon. Besides, Dual-TLD chips were latticed placed in the horizontal plane of beam central axis, in the treatment room to estimate the spatial dose distribution of neutron and photon. Gold foils were assisted in TLD dose calibrations. Neutron and photon dose distributions in phantom and spatial dose distributions in the THOR BNCT treatment room were both estimated in this work. Testing and improvement in THOR BNCT beam were continuative during these years. Results of this work could be the reference and be helpful for the further clinical trials in nearly future. (author)

  14. Biological dose estimation in a radiation accident involving low-dose ...

    African Journals Online (AJOL)

    Blood specimens were collected from 8 people 18 days after they had been accidentally exposed to a 947,2 GBq iridium192 source during industrial application. The equivalent whole-body dose received at day 0 was estimated using a model based on quantitative and qualitative chromosome aberration analysis in ...

  15. Estimate of ovarian dose and entrance skin dose in uterine artery embolization procedures

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Nasser, Felipe; Affonso, Breno B.; Araujo Junior, Raimundo T.; Zlotnik, Eduardo; Messina, Marcos L.; Baracat, Edmund C.

    2010-01-01

    The goal of this study was to estimate the ovarian dose and entrance skin dose (ESD) of patients who underwent uterine artery embolization (UAE) procedure. To achieve this, 49 UAE procedures were accompanied where the parameters of image acquisition were recorded for the calculation of the DEP from the output of the X-ray tube. The estimation of the ovarian dose was carried out by the insertion of a vaginal probe containing 3 TLD's. The obtained values were compared with the results of other authors and a higher value of ovarian dose (28,97 cGy) and ESD (403,57 cGy) was found in this work. Analysis of the results allowed to observe that this result was obtained mainly as a result of the high number of arteriography series and the frames/second rates employed. Following on from these observations, the protocol of EMUT was altered reducing the frames/seg rate from 2 to 1. Efforts with a view to reducing the number of arteriography series also became part of the next proceedings. (author)

  16. Estimation of population doses from diagnostic medical examinations in Japan, 1974. II. Estimation of genetically significant dose

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-03-01

    The genetically significant dose from radiographic and fluoroscopic examination in Japan has been estimated based on a 1974 nation wide survey of randomly sampled hospitals and clinics. The gonad dose during x-ray diagnosis was determined with an ionization chamber placed at the positions of ovary and testis in a Rando phantom. The instrumented phantom was irradiated with medical diagnostic x-rays on the basis of the exposure data on the patients selected in the nation wide survey. In the calculation of the genetically significant dose, the child expectancy of the patients that undergo each particular type of examination was assumed to be same as that of the general population. The resultant genetically significant dose was 11.1 and 5.43 mrad per person per year for radiography and fluoroscopy, respectively. These values were compared with those of 1960 and 1969. Though the number of examinations per year shows a yearly increase, the genetically significant dose is gradually on the decrease. This may be due to technical improvements in medical radiological practices.

  17. Dose estimation for space radiation protection

    International Nuclear Information System (INIS)

    Xu Feng; Xu Zhenhua; Huang Zengxin; Jia Xianghong

    2007-01-01

    For evaluating the effect of space radiation on human health, the dose was estimated using the models of space radiation environment, models of distribution of the spacecraft's or space suit's mass thickness and models of human body. The article describes these models and calculation methods. (authors)

  18. We can do better than effective dose for estimating or comparing low-dose radiation risks

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    The effective dose concept was designed to compare the generic risks of exposure to different radiation fields. More commonly these days, it is used to estimate or compare radiation-induced cancer risks. For various reasons, effective dose represents flawed science: for instance, the tissue-specific weighting factors used to calculate effective dose are a subjective mix of different endpoints; and the marked and differing age and gender dependencies for different health detriment endpoints are not taken into account. This paper suggests that effective dose could be replaced with a new quantity, ‘effective risk’, which, like effective dose, is a weighted sum of equivalent doses to different tissues. Unlike effective dose, where the tissue-dependent weighting factors are a set of generic, subjective committee-defined numbers, the weighting factors for effective risk are simply evaluated tissue-specific lifetime cancer risks per unit equivalent dose. Effective risk, which has the potential to be age and gender specific if desired, would perform the same comparative role as effective dose, be just as easy to estimate, be less prone to misuse, be more directly understandable, and would be based on solid science. An added major advantage is that it gives the users some feel for the actual numerical values of the radiation risks they are trying to control.

  19. Estimation of kidneys and urinary bladder doses based on the region of interest in 18fluorine-fluorodeoxyglucose positron emission tomography/computed tomography examination: a preliminary study.

    Science.gov (United States)

    Mustapha, Farida Aimi; Bashah, Farahnaz Ahmad Anwar; Yassin, Ihsan M; Fathinul Fikri, Ahmad Saad; Nordin, Abdul Jalil; Abdul Razak, Hairil Rashmizal

    2017-06-01

    Kidneys and urinary bladder are common physiologic uptake sites of 18fluorine-fluorodeoxyglucose ( 18 F-FDG) causing increased exposure of low energy ionizing radiation to these organs. Accurate measurement of organ dose is vital as 18 F-FDG is directly exposed to the organs. Organ dose from 18 F-FDG PET is calculated according to the injected 18 F-FDG activity with the application of dose coefficients established by International Commission on Radiological Protection (ICRP). But this dose calculation technique is not directly measured from these organs; rather it is calculated based on total injected activity of radiotracer prior to scanning. This study estimated the 18 F-FDG dose to the kidneys and urinary bladder in whole body positron emission tomography/computed tomography (PET/CT) examination by comparing dose from total injected activity of 18 F-FDG (calculated dose) and dose from organs activity based on the region of interest (ROI) (measured dose). Nine subjects were injected intravenously with the mean 18 F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of 18 F-FDG and organs activity concentration of 18 F-FDG based on drawn ROI with the application of recommended dose coefficients for 18 F-FDG described in the ICRP 80 and ICRP 106. The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%. There is a significant

  20. Patient-specific dose estimation for pediatric chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P. [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Global Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin 53188 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham North Carolina 27710 (United States)

    2008-12-15

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ

  1. Estimating effective doses to children from CT examinations

    International Nuclear Information System (INIS)

    Heron, J.C.L.

    2000-01-01

    Full text: Assessing doses to patients in diagnostic radiology is an integral part of implementing optimisation of radiation protection. Sources of normalised data are available for estimating doses to adults undergoing CT examinations, but for children this is not the case. This paper describes a simple method for estimating effective doses arising from paediatric CT examinations. First the effective dose to an adult is calculated, having anatomically matched the scanned regions of the child and the adult and also matched the irradiation conditions. A conversion factor is then applied to the adult effective dose, based on the region of the body being scanned - head, upper or lower trunk. This conversion factor is the child-to-adult ratio of the ratios of effective dose per entrance air kerma (in the absence of the patient) at the FAD. The values of these conversion factors were calculated by deriving effective dose per entrance air kerma at the FAD for new-born, 1, 5, 10, 15 and adult phantoms using four projections (AP, PA, left and right laterals) over a range of beam qualities and FADs.The program PCXMC was used for this purpose. Results to date suggest that the conversion factors to give effective doses for children undergoing CT examinations of the upper trunk are approximately 1.3, 1.2, 1.15, 1.1 and 1.05 for ages 0, 1, 5, 10 and 15 years respectively; CT of the lower trunk - 1.4, 1.3, 1.2, 1.2, 1.1; and CT of the head - 2.3, 2.0, 1.5, 1.3, 1.1. The dependence of these factors on beam quality (HVL from 4 to 10 mm Al) is less than 10%, with harder beams resulting in slightly smaller conversion factors. Dependence on FAD is also less than 10%. Major sources of uncertainties in the conversion factors include matching anatomical regions across the phantoms, and the presence of beam divergence in the z-direction when deriving the factors. The method described provides a simple means of estimating effective doses arising from paediatric CT examinations with

  2. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  3. Work plan for the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    1989-12-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that populations could have received from nuclear operations at the Hanford Site since 1944, with descriptions of uncertainties inherent in such estimates. The secondary objective is to make project records--information that HEDR staff members used to estimate radiation doses--available to the public. Preliminary dose estimates for a limited geographic area and time period, certain radionuclides, and certain populations are planned to be available in 1990; complete results are planned to be reported in 1993. Project reports and references used in the reports are available to the public in the DOE Public Reading Room in Richland, Washington. Project progress is documented in monthly reports, which are also available to the public in the DOE Public Reading Room.

  4. Estimated effects on radiation doses from alternatives in a spent fuel transportation system

    International Nuclear Information System (INIS)

    Schneider, K.J.; Ross, W.A.; Smith, R.I.

    1988-07-01

    This paper contains the results of a study of estimated radiation doses to the public and workers from the transport of spent fuel from commercial nuclear power reactors to a geologic repository. A postulated reference rail/legal-weight truck transportation system is defined that would use current transportation technology, and provide a breakdown of activities and time/distance/dose-rate estimates for each activity within the system. Collective doses are estimated for each of the major activities at the reactor site, in transit, and at the repository receiving facility. Annual individual doses to the maximally exposed individuals or groups of individuals are also estimated. The dose-reduction potentials and costs are estimated for a total of 17 conceptual alternatives and subalternatives to the postulated reference system. Most of the alternatives evaluated are estimated to provide both cost and dose reductions. The major conclusion is that the potential exists for significant future reductions in radiation doses to the public and workers and for reductions in costs compared to those based on a continuation of past practices in the US

  5. Estimated effects on radiation doses from alternatives in a spent fuel transportation system

    International Nuclear Information System (INIS)

    Schneider, K.J.; Ross, W.A.; Smith, R.I.

    1988-01-01

    This paper contains the results of a study of estimated radiation doses to the public and workers from the transport of spent fuel from commercial nuclear power reactors to a geologic repository. A postulated reference rail/legal-weight truck transportation system is defined that would use current transportation technology, and provide a breakdown of activities and time/distance/dose-rate estimates for each activity within the system. Collective doses are estimated for each of the major activities at the reactor site, in transit, and at the repository receiving facility. Annual individual doses to the maximally exposed individuals or groups of individuals also estimated. The dose-reduction potentials and costs are estimated for a total of 17 conceptual alternatives and subalternatives to the postulated reference system. Most of the alternatives evaluated are estimated to provide both cost and dose reductions. The major conclusion is that the potential exists for significant future reductions in radiation doses to the public and workers and for reductions in costs compared to those based on a continuation of past practices in the U.S

  6. Simplification of an MCNP model designed for dose rate estimation

    Science.gov (United States)

    Laptev, Alexander; Perry, Robert

    2017-09-01

    A study was made to investigate the methods of building a simplified MCNP model for radiological dose estimation. The research was done using an example of a complicated glovebox with extra shielding. The paper presents several different calculations for neutron and photon dose evaluations where glovebox elements were consecutively excluded from the MCNP model. The analysis indicated that to obtain a fast and reasonable estimation of dose, the model should be realistic in details that are close to the tally. Other details may be omitted.

  7. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  8. Estimation of dose in irradiated chicken bone by ESR method

    International Nuclear Information System (INIS)

    Tanabe, Hiroko; Hougetu, Daisuke

    1998-01-01

    The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was γ-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones initially irradiated at 3.0kGy, 1.0kGy, 0.50kGy and 0.25kGy were 3.4kGy, 1.3kGy, 0.81kGy and 0.57kGy. (author)

  9. Patient absorbed radiation doses estimation related to irradiation anatomy

    International Nuclear Information System (INIS)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes

    2014-01-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector

  10. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  11. Estimation of effective dose equivalente from external irradiations

    International Nuclear Information System (INIS)

    Wakabayashi, T.

    1985-07-01

    A methodology for computing effective dose equivalent, derived from the computer code ALGAM: Monte Carlo Estimation of Internal Dose from Gamma-ray Sources in a Phantom Man, developed at Oak Ridge National Laboratory, is presented. The modified code was run for 12 different photon energy levels, from 0,010 Mev to 4.0 Mev, which provides computing the absorved dose, for these energy levels, in each one of the 97 organs of the original code. The code also was run for the principal energy levels used in the calibration of the dosimetric films. The results of the absorved doses per photon obtained for these levels of energy have been transformed in effective dose equivalents. (M.A.C.) [pt

  12. Estimation of the Radon-induced Dose for Russia's Population: Methods and Results

    International Nuclear Information System (INIS)

    Marenny, A.M.; Savkin, M.N.; Shinkarev, S.M.

    2000-01-01

    A model is proposed for inferring the radon-induced annual average collective and personal doses, as well as the dose distribution of the population, all over Russia from selective radon monitoring in some regions of Russia. The model assumptions and the selective radon monitoring results that underlie the numerical estimates obtained for different population groups are presented. The current estimate of the collective radon-induced dose received by the population of Russia (148,100,000 as of 1996) is about 130,000 man Sv, of which 55,000 man Sv is for the rural population (27% of the total population) and 75,000 man Sv for the urban population (73% of the total). The average radon-induced personal dose in Russia is estimated to be about 0.87 mSv. About 1,000,000 people receive annual doses above 10 mSv, including some 200,000 people who receive doses above 20 mSv annually. The ways of making the current estimates more accurate are outlined. (author)

  13. Literature and data review for the surface-water pathway: Columbia River and adjacent coastal areas. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.H.; Dirkes, R.L.; Napier, B.A.

    1992-11-01

    As part of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle, Pacific Northwest Laboratories reviewed literature and data on radionuclide concentrations and distribution in the water, sediment, and biota of the Columbia River and adjacent coastal areas. Over 600 documents were reviewed including Hanford reports, reports by offsite agencies, journal articles, and graduate theses. Radionuclide concentration data were used in preliminary estimates of individual dose for the period 1964 through 1966. This report summarizes the literature and database reviews and the results of the preliminary dose estimates.

  14. Simplification of an MCNP model designed for dose rate estimation

    Directory of Open Access Journals (Sweden)

    Laptev Alexander

    2017-01-01

    Full Text Available A study was made to investigate the methods of building a simplified MCNP model for radiological dose estimation. The research was done using an example of a complicated glovebox with extra shielding. The paper presents several different calculations for neutron and photon dose evaluations where glovebox elements were consecutively excluded from the MCNP model. The analysis indicated that to obtain a fast and reasonable estimation of dose, the model should be realistic in details that are close to the tally. Other details may be omitted.

  15. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  16. The points for attention in retrospective personal dose estimate

    International Nuclear Information System (INIS)

    Wang Wuan

    1994-01-01

    The points which the attention should be paid to in the retrospective personal dose estimate are discussed. They are representative of the dose data, truthfulness of the operation history, accuracy of the man-hour statistics, and rationality of the parameters selection

  17. Proof of concept and dose estimation with binary responses under model uncertainty.

    Science.gov (United States)

    Klingenberg, B

    2009-01-30

    This article suggests a unified framework for testing Proof of Concept (PoC) and estimating a target dose for the benefit of a more comprehensive, robust and powerful analysis in phase II or similar clinical trials. From a pre-specified set of candidate models, we choose the ones that best describe the observed dose-response. To decide which models, if any, significantly pick up a dose effect, we construct the permutation distribution of the minimum P-value over the candidate set. This allows us to find critical values and multiplicity adjusted P-values that control the familywise error rate of declaring any spurious effect in the candidate set as significant. Model averaging is then used to estimate a target dose. Popular single or multiple contrast tests for PoC, such as the Cochran-Armitage, Dunnett or Williams tests, are only optimal for specific dose-response shapes and do not provide target dose estimates with confidence limits. A thorough evaluation and comparison of our approach to these tests reveal that its power is as good or better in detecting a dose-response under various shapes with many more additional benefits: It incorporates model uncertainty in PoC decisions and target dose estimation, yields confidence intervals for target dose estimates and extends to more complicated data structures. We illustrate our method with the analysis of a Phase II clinical trial. Copyright (c) 2008 John Wiley & Sons, Ltd.

  18. Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation.

    Science.gov (United States)

    Shirley, Ben; Li, Yanxin; Knoll, Joan H M; Rogan, Peter K

    2017-09-04

    Biological radiation dose can be estimated from dicentric chromosome frequencies in metaphase cells. Performing these cytogenetic dicentric chromosome assays is traditionally a manual, labor-intensive process not well suited to handle the volume of samples which may require examination in the wake of a mass casualty event. Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates this process by examining sets of metaphase images using machine learning-based image processing techniques. The software selects appropriate images for analysis by removing unsuitable images, classifies each object as either a centromere-containing chromosome or non-chromosome, further distinguishes chromosomes as monocentric chromosomes (MCs) or dicentric chromosomes (DCs), determines DC frequency within a sample, and estimates biological radiation dose by comparing sample DC frequency with calibration curves computed using calibration samples. This protocol describes the usage of ADCI software. Typically, both calibration (known dose) and test (unknown dose) sets of metaphase images are imported to perform accurate dose estimation. Optimal images for analysis can be found automatically using preset image filters or can also be filtered through manual inspection. The software processes images within each sample and DC frequencies are computed at different levels of stringency for calling DCs, using a machine learning approach. Linear-quadratic calibration curves are generated based on DC frequencies in calibration samples exposed to known physical doses. Doses of test samples exposed to uncertain radiation levels are estimated from their DC frequencies using these calibration curves. Reports can be generated upon request and provide summary of results of one or more samples, of one or more calibration curves, or of dose estimation.

  19. Thermally assisted OSL application for equivalent dose estimation; comparison of multiple equivalent dose values as well as saturation levels determined by luminescence and ESR techniques for a sedimentary sample collected from a fault gouge

    Energy Technology Data Exchange (ETDEWEB)

    Şahiner, Eren, E-mail: sahiner@ankara.edu.tr; Meriç, Niyazi, E-mail: meric@ankara.edu.tr; Polymeris, George S., E-mail: gspolymeris@ankara.edu.tr

    2017-02-01

    Highlights: • Multiple equivalent dose estimations were carried out. • Additive ESR and regenerative luminescence were applied. • Preliminary SAR results employing TA-OSL signal were discussed. • Saturation levels of ESR and luminescence were investigated. • IRSL{sub 175} and SAR TA-OSL stand as very promising for large doses. - Abstract: Equivalent dose estimation (D{sub e}) constitutes the most important part of either trap-charge dating techniques or dosimetry applications. In the present work, multiple, independent equivalent dose estimation approaches were adopted, using both luminescence and ESR techniques; two different minerals were studied, namely quartz as well as feldspathic polymineral samples. The work is divided into three independent parts, depending on the type of signal employed. Firstly, different D{sub e} estimation approaches were carried out on both polymineral and contaminated quartz, using single aliquot regenerative dose protocols employing conventional OSL and IRSL signals, acquired at different temperatures. Secondly, ESR equivalent dose estimations using the additive dose procedure both at room temperature and at 90 K were discussed. Lastly, for the first time in the literature, a single aliquot regenerative protocol employing a thermally assisted OSL signal originating from Very Deep Traps was applied for natural minerals. Rejection criteria such as recycling and recovery ratios are also presented. The SAR protocol, whenever applied, provided with compatible D{sub e} estimations with great accuracy, independent on either the type of mineral or the stimulation temperature. Low temperature ESR signals resulting from Al and Ti centers indicate very large D{sub e} values due to bleaching in-ability, associated with large uncertainty values. Additionally, dose saturation of different approaches was investigated. For the signal arising from Very Deep Traps in quartz saturation is extended almost by one order of magnitude. It is

  20. Estimation of doses to patients from ''complex'' conventional X-ray examinations

    International Nuclear Information System (INIS)

    Calzado, A.; Vano, E.; Moran, P.; Ruiz, S.; Gonzalez, L.; Castellote, C.

    1991-01-01

    A numerical method has been developed to estimate organ doses and effective dose-equivalent for patients undergoing three 'complex' examinations (barium meal, barium enema and intravenous urography). The separation of radiological procedures into a set of standard numerical views is based on the use of Monte Carlo conversion factors and measurements within a Remab phantom. Radiation doses measured in a phantom for such examinations were compared with predictions of the ''numerical'' method. Dosimetric measurements with thermoluminescent dosemeters attached to the patient's skin along with measurements of the dose-area product during the examination have enabled the derivation of organ doses and to estimate effective dose-equivalent. Mean frequency weighted values of dose-area product, energy imparted to the patient, doses to a set of organs and effective dose-equivalent in the area of Madrid are reported. Comparisons of results with those from similar surveys in other countries were made. (author)

  1. Estimation of doses to patients with chronic radiation sickness from external occupational exposure

    International Nuclear Information System (INIS)

    Jia Delin; Dai Guangfu

    1991-01-01

    The doses to patients with chronic radiation sickness who had engaged in diagnostic radiology have been estimated according to the radiation work load, type and capacity of X-ray equipment, protection conditions, data of nationwide survey on doses to X-ray workers in China, or the data of dose monitoring in working places. Based on the activities of radium sources, time taken up in performing radium therapy, distance to radium sources and radiation work load, the doses to patients who had engaged in radium therapy have been estimated. The results of estimated average doses for 29 cases of chronic radiation sickness are given. Their average red marrow dose, trunk dose and effective dose equivalent are 1.3 Gy, 1.2 Gy and 1.6 Sv, respectively

  2. Hygienic estimation of population doses due to stratospheric fallout

    International Nuclear Information System (INIS)

    Marej, A.N.; Knizhnikov, V.A.

    1980-01-01

    The hygienic estimation of external and internal irradiation of the USSR population due to stratospheric global fallouts of fission products after nuclear explosions and weapon tests, is carried out. Numerical values which characterize the dose-effect dependence in the case of radiation of marrow, bone tissue and whole body are presented. Values of mean individual and population doses of irradiation due to global fallouts within 1963-1975, types of injury and the number of mortal cases due to malignant neoplasms are presented. A conclusion is made that the contribution of radiation due to stratospheric fallouts in the mortality due to malignant neoplasms is insignificant. Annual radiation doses, conditioned by global fallouts within the period of 1963-1975 constitute but several percent from the dose of radiation of the natural radiation background. Results of estimation of genetic consequences of irradiation due to atmospheric fallouts are presented

  3. Single point estimation of phenytoin dosing: a reappraisal.

    Science.gov (United States)

    Koup, J R; Gibaldi, M; Godolphin, W

    1981-11-01

    A previously proposed method for estimation of phenytoin dosing requirement using a single serum sample obtained 24 hours after intravenous loading dose (18 mg/Kg) has been re-evaluated. Using more realistic values for the volume of distribution of phenytoin (0.4 to 1.2 L/Kg), simulations indicate that the proposed method will fail to consistently predict dosage requirements. Additional simulations indicate that two samples obtained during the 24 hour interval following the iv loading dose could be used to more reliably predict phenytoin dose requirement. Because of the nonlinear relationship which exists between phenytoin dose administration rate (RO) and the mean steady state serum concentration (CSS), small errors in prediction of the required RO result in much larger errors in CSS.

  4. On the uncertainties in effective dose estimates of adult CT head scans

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan against the risk of radiation-induced cancer. The question arises: What is the uncertainty in these effective dose estimates? This study calculates the uncertainty of effective dose estimates produced by three computer programs (CT-EXPO, CTDosimetry, and ImpactDose) and one method that makes use of dose-length product (DLP) values. Uncertainties were calculated in accordance with an internationally recognized uncertainty analysis guide. For each of the four methods, the smallest and largest overall uncertainties (stated at the 95% confidence interval) were: 20%-31% (CT-EXPO), 15%-28% (CTDosimetry), 20%-36% (ImpactDose), and 22%-32% (DLP), respectively. The overall uncertainties for each method vary due to differences in the uncertainties of factors used in each method. The smallest uncertainties apply when the CT dose index for the scanner has been measured using a calibrated pencil ionization chamber

  5. Estimating the Absorbed Dose to Critical Organs During Dual X-ray Absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari-Dizaji, M.; Sharafi, A. A.; Larijani, B.; Mokhlesian, N.; Hasanzadeh, H. [Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2008-04-15

    Objective : The purpose of this study is to estimate a patient's organ dose (effective dose) during performance of dual X-ray absorptiometry by using the correlations derived from the surface dose and the depth doses in an anthropomorphic phantom. Materials and Methods : An anthropomorphic phantom was designed and TLDs (Thermoluminescent Dosimeters) were placed at the surface and these were also inserted at different depths of the thyroid and uterus of the anthropomorphic phantom. The absorbed doses were measured on the phantom for the spine and femur scan modes. The correlation coefficients and regression functions between the absorbed surface dose and the depth dose were determined. The derived correlation was then applied for 40 women patients to estimate the depth doses to the thyroid and uterus. Result : There was a correlation between the surface dose and depth dose of the thyroid and uterus in both scan modes. For the women's dosimetry, the average surface doses of the thyroid and uterus were 1.88 {mu}Gy and 1.81 Gy, respectively. Also, the scan center dose in the women was 5.70 Gy. There was correlation between the thyroid and uterus surface doses, and the scan center dose. Conclusion : We concluded that the effective dose to the patient's critical organs during dual X-ray absorptiometry can be estimated by the correlation derived from phantom dosimetry.

  6. Estimating the Absorbed Dose to Critical Organs During Dual X-ray Absorptiometry

    International Nuclear Information System (INIS)

    Mokhtari-Dizaji, M.; Sharafi, A. A.; Larijani, B.; Mokhlesian, N.; Hasanzadeh, H.

    2008-01-01

    Objective : The purpose of this study is to estimate a patient's organ dose (effective dose) during performance of dual X-ray absorptiometry by using the correlations derived from the surface dose and the depth doses in an anthropomorphic phantom. Materials and Methods : An anthropomorphic phantom was designed and TLDs (Thermoluminescent Dosimeters) were placed at the surface and these were also inserted at different depths of the thyroid and uterus of the anthropomorphic phantom. The absorbed doses were measured on the phantom for the spine and femur scan modes. The correlation coefficients and regression functions between the absorbed surface dose and the depth dose were determined. The derived correlation was then applied for 40 women patients to estimate the depth doses to the thyroid and uterus. Result : There was a correlation between the surface dose and depth dose of the thyroid and uterus in both scan modes. For the women's dosimetry, the average surface doses of the thyroid and uterus were 1.88 μGy and 1.81 Gy, respectively. Also, the scan center dose in the women was 5.70 Gy. There was correlation between the thyroid and uterus surface doses, and the scan center dose. Conclusion : We concluded that the effective dose to the patient's critical organs during dual X-ray absorptiometry can be estimated by the correlation derived from phantom dosimetry

  7. Skin dose estimation due to a contamination by a radionuclide β emitter: are doses equivalent good estimator of protection quantities?

    International Nuclear Information System (INIS)

    Bourgois, L.

    2011-01-01

    When handling radioactive β emitters, measurements in terms of personal dose equivalents H p (0.07) are used to estimate the equivalent dose limit to skin or extremities given by regulations. First of all, analytical expressions for individual dose equivalents H p (0.07) and equivalent doses to the extremities H skin are given for a point source and for contamination with a radionuclide β emitter. Second of all, operational quantities and protection quantities are compared. It is shown that in this case the operational quantities significantly overstate the protection quantities. For a skin contamination the ratio between operational quantities and protection quantities is 2 for a maximum β energy of 3 MeV and 90 for a maximum β energy of 150 keV. (author)

  8. Organ dose estimates for the Japanese atomic-bomb survivors

    International Nuclear Information System (INIS)

    Kerr, G.D.

    1978-10-01

    Recent studies concerning radiation risks to man by the Committee on Biological Effects of Ionizing Radiation of the National Academy of Sciences-National Research Council and the United Nations Scientific Committee on the Effects of Atomic Radiation have emphasized the need for estimates of dose to organs of the Japanese atomic-bomb survivors. Shielding of internal organs by the body has been investigated for fission-weapon gamma rays and neutrons, and ratios of mean absorbed dose in a number of organs to survivors' T65D assignments of tissue kerma in air are provided for adults. Ratios of mean absorbed dose to tissue kerma in air are provided also for the thyroid and active bone marrow of juveniles. These organ dose estimates for juveniles are of interest in studies of radiation risks due to an elevated incidence of leukemia and thyroid cancer in survivors exposed as children compared to survivors exposed as adults

  9. Preliminary safety assessment study for the conceptual design of a repository in tuff at Yucca Mountain

    International Nuclear Information System (INIS)

    Jackson, J.L.; Gram, H.F.; Hong, K.J.; Ng, H.S.; Pendergrass, A.M.

    1984-12-01

    Preliminary estimates of the upper bounds on postulated worst-case radiological releases resulting from possible accidents during the operating period of a prospective repository in tuff at Yucca Mountain are presented. Possible disrupting events are screened to identify the accidents of greatest potential consequence. The radiological dose commitments for the general public and repository personnel are estimated for postulated releases caused by natural phenomena, man-made events, and operational accidents. All postulated worst-case releases result in doses to the public that are lower than the 0.5-rem, whole-body dose-per-accident limit set by the Nuclear Regulatory Commission (NRC) in 10 CFR 60. Doses to repository personnel are within the NRC's 5.0-rem/yr occupational exposure limit set in 10 CFR 20 for normal operations. Doses are within this limit for all accidents except the transportation accident and fire in a drift. A preliminary risk assessment has also been performed. Based on this preliminary safety study, the proposed site boundaries and design criteria routinely used in constructing nuclear facilities appear to be adequate to protect the safety of the general public during the operating phase of the repository

  10. Radiation dose estimates for carbon-11-labelled PET tracers

    International Nuclear Information System (INIS)

    Aart, Jasper van der; Hallett, William A.; Rabiner, Eugenii A.; Passchier, Jan; Comley, Robert A.

    2012-01-01

    Introduction: Carbon-11-labelled positron emission tomography (PET) tracers commonly used in biomedical research expose subjects to ionising radiation. Dosimetry is the measurement of radiation dose, but also commonly refers to the estimation of health risk associated with ionising radiation. This review describes radiation dosimetry of carbon-11-labelled molecules in the context of current PET research and the most widely used regulatory guidelines. Methods: A MEDLINE literature search returned 42 articles; 32 of these were based on human PET data dealing with radiation dosimetry of carbon-11 molecules. Radiation burden expressed as effective dose and maximum absorbed organ dose was compared between tracers. Results: All but one of the carbon-11-labelled PET tracers have an effective dose under 9 μSv/MBq, with a mean of 5.9 μSv/MBq. Data show that serial PET scans in a single subject are feasible for the majority of radiotracers. Conclusion: Although differing in approach, the two most widely used regulatory frameworks (those in the USA and the EU) do not differ substantially with regard to the maximum allowable injected activity per PET study. The predictive validity of animal dosimetry models is critically discussed in relation to human dosimetry. Finally, empirical PET data are related to human dose estimates based on homogenous distribution, generic models and maximum cumulated activities. Despite the contribution of these models to general risk estimation, human dosimetry studies are recommended where continued use of a new PET tracer is foreseen.

  11. Estimates of effective dose in adult CT examinations

    International Nuclear Information System (INIS)

    Mohamed, Mustafa Awad Elhaj.

    2015-12-01

    The goal of study was to estimate effective dose (E) in adult CT examinations for Toshiba X64 slice using CT. Exp version 2.5 software in Sudan. Using of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. lack of optimized protocols could be an additional source of increased dose in developing countries. In order to achieve these objectives, data of CT-scanner has been collected from three hospitals ( ANH, ZSH and MMH). Data collected included equipment information and scan parameters for individual patients, who were used to asses. 300 adult patients underwent head, chest, abdomen-pelvis and peivis CT examinations. The CT1_w , CTD1_vol, DLP, patient effective dos and organ doses were estimated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scan length. The mean effective dose in this study in the Brain, PNS, Chest, pulmonary, Abdomen-pelvis, Pelvis, KUB and CTU were 3.2 mSv, 2.6 mSv, 18.9 mSv 17.6 mSv 27.1 mSv, 11.2 mSv, 9.6 mSv and 23.7 mSv respectively, and organ equivalent, doses presented in this study in this study for the eye lens (for head), lungs and thymus ( for chest) , liver, kidney and small intest ( for abdomen t-pelvis), bladder, uterus and gonads ( for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Tanzania, Australia, Canada and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body

  12. A Study on the Establishment of Radiation Dose Estimation Procedure for Accumulated Radioactive Ions for RAON ISOL System

    Directory of Open Access Journals (Sweden)

    KIM Do Hyun

    2017-01-01

    Full Text Available For purposes of various experiments, RAON heavy ion accelerator facility has been designed in Korea. ISOL is one system of RAON accelerators to generate and separate rare isotopes. Radioactive ions generated from target-proton reactions are separated and accumulated at separation devices. The accumulated isotopes release the gamma radiations; therefore, the radiation safety must be clearly estimated. In this study, a process to evaluate radiations from the accumulated ions was proposed by modifying FISPACT code. The proposed process was validated by comparing a solution of single element decay problem. Using the process, a preliminary study for radiation doses were performed in a virtual separation devise.

  13. Time improvement of photoelectric effect calculation for absorbed dose estimation

    International Nuclear Information System (INIS)

    Massa, J M; Wainschenker, R S; Doorn, J H; Caselli, E E

    2007-01-01

    Ionizing radiation therapy is a very useful tool in cancer treatment. It is very important to determine absorbed dose in human tissue to accomplish an effective treatment. A mathematical model based on affected areas is the most suitable tool to estimate the absorbed dose. Lately, Monte Carlo based techniques have become the most reliable, but they are time expensive. Absorbed dose calculating programs using different strategies have to choose between estimation quality and calculating time. This paper describes an optimized method for the photoelectron polar angle calculation in photoelectric effect, which is significant to estimate deposited energy in human tissue. In the case studies, time cost reduction nearly reached 86%, meaning that the time needed to do the calculation is approximately 1/7 th of the non optimized approach. This has been done keeping precision invariant

  14. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    International Nuclear Information System (INIS)

    Hardy, A; Bostani, M; McMillan, K; Zankl, M; Cagnon, C; McNitt-Gray, M

    2016-01-01

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  15. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, A; Bostani, M [University of California, Los Angeles, Los Angeles, CA (United States); McMillan, K [Mayo Clinic, Rochester, MN (United States); Zankl, M [Helmholtz Zentrum Munchen, Neuherberg (Germany); Cagnon, C [UCLA Medical Center, Los Angeles, CA (United States); McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  16. Radiation dose to technologists per nuclear medicine examination and estimation of annual dose.

    Science.gov (United States)

    Bayram, Tuncay; Yilmaz, A Hakan; Demir, Mustafa; Sonmez, Bircan

    2011-03-01

    Conventional diagnostic nuclear medicine applications have been continuously increasing in most nuclear medicine departments in Turkey, but to our knowledge no one has studied the doses to technologists who perform nuclear medicine procedures. Most nuclear medicine laboratories do not have separate control rooms for technologists, who are quite close to the patient during data acquisition. Technologists must therefore stay behind lead shields while performing their task if they are to reduce the radiation dose received. The aim of this study was to determine external radiation doses to technologists during nuclear medicine procedures with and without a lead shield. Another aim was to investigate the occupational annual external radiation doses to Turkish technologists. This study used a Geiger-Müller detector to measure dose rates to technologists at various distances from patients (0.25, 0.50, 1, and 2 m and behind a lead shield) and determined the average time spent by technologists at these distances. Deep-dose equivalents to technologists were obtained. The following conventional nuclear medicine procedures were considered: thyroid scintigraphy performed using (99m)Tc pertechnetate, whole-body bone scanning performed using (99m)Tc-methylene diphosphonate, myocardial perfusion scanning performed using (99m)Tc-methoxyisobutyl isonitrile, and (201)Tl (thallous chloride) and renal scanning performed using (99m)Tc-dimercaptosuccinic acid. The measured deep-dose equivalent to technologists per procedure was within the range of 0.13 ± 0.05 to 0.43 ± 0.17 μSv using a lead shield and 0.21 ± 0.07 to 1.01 ± 0.46 μSv without a lead shield. Also, the annual individual dose to a technologist performing only a particular scintigraphic procedure throughout a year was estimated. For a total of 95 clinical cases (71 patients), effective external radiation doses to technologists were found to be within the permissible levels. This study showed that a 2-mm lead shield

  17. Preliminary Calculations of Shutdown Dose Rate for the CTS Diagnostics System

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Nonbøl, Erik; Lauritzen, Bent

    2015-01-01

    DTU and IST 2 are partners in the design of a collective Thomson Scattering (CTS) diagnostics for ITER through a contract with F4E. The CTS diagnostic utilizes probing radiation of ~60 GHz emitted into the plasma and, using a mirror, collects the scattered radiation by an array of receivers. Having...... on supplying input which affect the system design. Examples include: - Heatloads on plasma facing mirrors and preliminary stress and thermal analysis - Port plug cooling requirements and it's dependence on system design (in particular blanket cut-out) - Shutdown dose-rate calculations (relative analysis...

  18. Estimation of population doses from diagnostic medical examinations in Japan, 1974. IV. Dose estimation of fetus exposed in utero to diagnostic x rays

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-07-01

    In fetus exposed in utero to diagnostic x rays for the medical examinations of the mother, the absorbed dose has been estimated on the basis of a 1974 nation wide radiological survey. The results of the survey showed that the number of radiographs per year connected with pregnant women was 0.32 million for chest examination excluding mass surveys. 0.29 million for obstetrical examinations including pelvimetry, and 0.21 million for abdominal and pelvic examinations with a total of 0.82 million. The dose absorbed in the fetus was measured with an ionization chamber placed at the hypothetical center of the fetus in an ''average woman'' Rando phantom in which a maternal body was simulated by adding MixDp materials. ''The collective dose'' to the fetus in the pregnant women receiving a given type of examination was calculated from the number of radiographs per year connected with the pregnant women and the fetal doses. The percapita mean marrow dose (CMD), the leukemia significant dose (LSD) and the genetically significant dose (GSD) for the fetus were determined from the collective dose, taking into account the birth expectancy, the child expectancy, life expectancy and significant factor for the fetus. The collective dose to the fetus was estimated to be 9.3 x 10/sup 4/ man rad per year. The resultant values of CMD, LSD and GSD were 0.81 mrad per year, 0.79 mrad per person per year and 1.44 mrad per person per year, respectively.

  19. Automated lung module detection at low-dose CT: preliminary experience

    International Nuclear Information System (INIS)

    Goo, Jin-Mo; Lee, Jeong-Won; Lee, Hyun-Ju; Kim, Seung-Wan; Kim, Jong-Hyo; Im, Jung-Gi

    2003-01-01

    To determine the usefulness of a computer-aided diagnosis (CAD) system for the automated detection of lung nodules at low-dose CT. A CAD system developed for detecting lung nodules was used to process the data provided by 50 consecutive low-dose CT scans. The results of an initial report, a second look review by two chest radiologists, and those obtained by the CAD system were compared, and by reviewing all of these, a gold standard was established. By applying the gold standard, a total of 52 nodules were identified (26 with a diameter ≤ 5 mm; 26 with a diameter > 5 mm). Compared to an initial report, four additional nodules were detected by the CAD system. Three of these, identified only at CAD, formed part of the data used to derive the gold standard. For the detection of nodules > 5 mm in diameter, sensitivity was 77% for the initial report, for the second look review, and 88% for the second look review,and 65% for the CAD system. There were 8.0 ± 5.2 false-positive CAD results per CT study. These preliminary results indicate that a CAD system may improve the detection of pulmonary nodules at low-dose CT

  20. Estimation of the total absorbed dose by quartz in retrospective conditions

    International Nuclear Information System (INIS)

    Correcher, V.; Delgado, A.

    2003-01-01

    The estimation of the total absorbed dose is of great interest in areas affected by a radiological accident when no conventional dosimetric systems are available. This paper reports about the usual methodology employed in dose reconstruction from the thermoluminescence (TL) properties of natural quartz, extracted from selected ceramic materials (12 bricks) picked up in the Chernobyl area. It has been possible to evaluate doses under 50mGy after more than 11 years later since the radiological accident happened. The main advance of this fact is the reduction of the commonly accepted limit dose estimation more than 20 times employing luminescence methods. (Author) 11 refs

  1. Fetus dose estimation in thyroid cancer post-surgical radioiodine therapy

    International Nuclear Information System (INIS)

    Mianji, Fereidoun A.; Karimi Diba, Jila; Babakhani, Asad

    2015-01-01

    Unrecognised pregnancy during radioisotope therapy of thyroid cancer results in hardly definable embryo/fetus exposures, particularly when the thyroid gland is already removed. Sources of such difficulty include uncertainty in data like pregnancy commencing time, amount and distribution of metastasized thyroid cells in body, effect of the thyroidectomy on the fetus dose coefficient etc. Despite all these uncertainties, estimation of the order of the fetus dose in most cases is enough for medical and legal decision-making purposes. A model for adapting the dose coefficients recommended by the well-known methods to the problem of fetus dose assessment in athyrotic patients is proposed. The model defines a correction factor for the problem and ensures that the fetus dose in athyrotic pregnant patients is less than the normal patients. A case of pregnant patient undergone post-surgical therapy by I-131 is then studied for quantitative comparison of the methods. The results draw a range for the fetus dose in athyrotic patients using the derived factor. This reduces the concerns on under- or over-estimation of the embryo/fetus dose and is helpful for personal and/or legal decision-making on abortion. (authors)

  2. Uncertainties on lung doses from inhaled plutonium.

    Science.gov (United States)

    Puncher, Matthew; Birchall, Alan; Bull, Richard K

    2011-10-01

    In a recent epidemiological study, Bayesian uncertainties on lung doses have been calculated to determine lung cancer risk from occupational exposures to plutonium. These calculations used a revised version of the Human Respiratory Tract Model (HRTM) published by the ICRP. In addition to the Bayesian analyses, which give probability distributions of doses, point estimates of doses (single estimates without uncertainty) were also provided for that study using the existing HRTM as it is described in ICRP Publication 66; these are to be used in a preliminary analysis of risk. To infer the differences between the point estimates and Bayesian uncertainty analyses, this paper applies the methodology to former workers of the United Kingdom Atomic Energy Authority (UKAEA), who constituted a subset of the study cohort. The resulting probability distributions of lung doses are compared with the point estimates obtained for each worker. It is shown that mean posterior lung doses are around two- to fourfold higher than point estimates and that uncertainties on doses vary over a wide range, greater than two orders of magnitude for some lung tissues. In addition, we demonstrate that uncertainties on the parameter values, rather than the model structure, are largely responsible for these effects. Of these it appears to be the parameters describing absorption from the lungs to blood that have the greatest impact on estimates of lung doses from urine bioassay. Therefore, accurate determination of the chemical form of inhaled plutonium and the absorption parameter values for these materials is important for obtaining reliable estimates of lung doses and hence risk from occupational exposures to plutonium.

  3. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2014-10-15

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach. (orig.)

  4. Development of the methodology for estimation of dose from a source

    International Nuclear Information System (INIS)

    Golebaone, E.M.

    2012-04-01

    The geometry of a source plays an important role when determining which method to apply in order to accurately estimate dose from a source. If wrong source geometry is used the dose received may be underestimated or overestimated therefore this may lead to wrong decision in dealing with the exposure situation. In this project moisture density gauge was used to represent a point source in order to demonstrate the key parameters to be used when estimating dose from point source. The parameters to be considered are activity of the source, the ambient dose rate, gamma constant for the radionuclide, as well as the transport index on the package of the source. The distance from the source, and the time spent in the radiation field must be known in order to calculate the dose. (author)

  5. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  6. An estimate of the doubling dose of ionizing radiation for humans

    International Nuclear Information System (INIS)

    Neel, J.V.

    1990-01-01

    All accumulated data on the children of Hiroshima and Nagasaki survivors have been analyzed employing the revised procedures for estimating gonadal radiation exposures that became effective in 1986. The basic statistical procedure employed has been to obtain a linear regression of indicator on the combined gonadal exposures of the parents. There is no statistically significant regression of indicator on dose for any of the indicators; however, it is accepted that some mutations were produced in the survivors of the bombings. The implications of the data for the genetic doubling dose of radiation for humans have been explored. The appropriate dose rate factor to be applied in extrapolating to the effect of chronic radiation is 2. This leads to a doubling dose estimate for the chronic irradiation of humans of between 3.4 and 4.5 Sv. The error is large but indeterminate, but the estimate is based on conservative assumptions. (3 tabs.)

  7. Dose estimation by biological methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; David C, L.; Serment G, J.; Brena V, M.

    1997-01-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  8. RADTRAD: A simplified model for RADionuclide Transport and Removal And Dose estimation

    International Nuclear Information System (INIS)

    Humphreys, S.L.; Miller, L.A.; Monroe, D.K.; Heames, T.J.

    1998-04-01

    This report documents the RADTRAD computer code developed for the U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Reactor Regulation (NRR) to estimate transport and removal of radionuclides and dose at selected receptors. The document includes a users' guide to the code, a description of the technical basis for the code, the quality assurance and code acceptance testing documentation, and a programmers' guide. The RADTRAD code can be used to estimate the containment release using either the NRC TID-14844 or NUREG-1465 source terms and assumptions, or a user-specified table. In addition, the code can account for a reduction in the quantity of radioactive material due to containment sprays, natural deposition, filters, and other natural and engineered safety features. The RADTRAD code uses a combination of tables and/or numerical models of source term reduction phenomena to determine the time-dependent dose at user-specified locations for a given accident scenario. The code system also provides the inventory, decay chain, and dose conversion factor tables needed for the dose calculation. The RADTRAD code can be used to assess occupational radiation exposures, typically in the control room; to estimate site boundary doses; and to estimate dose attenuation due to modification of a facility or accident sequence

  9. Estimation of Dose Received in Decommissioning of Phosphate Acid Factory-Petro Kimia Gresik

    International Nuclear Information System (INIS)

    Lubis, Erwansyah; Heru Umbara; Agus Gindo S

    2007-01-01

    The estimation of dose received in decommissioning of Phosphate Acid Factory-Petro Kimia Gresik (PAF-PKG) was carried out. The external dose estimated base on the radiation rate in each working area of zona-1, 2, 3 and 4. The internal dose estimated base on the radionuclides activity and diameter of particulate exist in each working area. The calculation of the internal dose was carried out by LUDEP 2.0 computer code. The results indicated that in the normal activity of decommissioning, the effective dose will received by the worker per year were 0.27 mSv in zona-1, 1.23 mSv in zona-2, 1.37 mSv in zona-3 and 11.85 mSv in zona-4. The internal dose received when a worse accident happens in decommissioning activity is 21.06 mSv for lung organ or 4.2 % of the dose limit for that organ. Based on the discussion above, indicated that in the decommissioning of PAF-PKG the dose received by the workers is far lower than the dose limit. (author)

  10. Method of estimating patient skin dose from dose displayed on medical X-ray equipment with flat panel detector

    International Nuclear Information System (INIS)

    Fukuda, Atsushi; Koshida, Kichiro; Togashi, Atsuhiko; Matsubara, Kousuke

    2004-01-01

    The International Electrotechnical Commission (IEC) has stipulated that medical X-ray equipment for interventional procedures must display radiation doses such as air kerma in free air at the interventional reference point and dose area product to establish radiation safety for patients (IEC 60601-2-43). However, it is necessary to estimate entrance skin dose for the patient from air kerma for an accurate risk assessment of radiation skin injury. To estimate entrance skin dose from displayed air kerma in free air at the interventional reference point, it is necessary to consider effective energy, the ratio of the mass-energy absorption coefficient for skin and air, and the backscatter factor. In addition, since automatic exposure control is installed in medical X-ray equipment with flat panel detectors, it is necessary to know the characteristics of control to estimate exposure dose. In order to calculate entrance skin dose under various conditions, we investigated clinical parameters such as tube voltage, tube current, pulse width, additional filter, and focal spot size, as functions of patient body size. We also measured the effective energy of X-ray exposure for the patient as a function of clinical parameter settings. We found that the conversion factor from air kerma in free air to entrance skin dose is about 1.4 for protection. (author)

  11. Estimate of dose in interventional radiology: a study of cases

    International Nuclear Information System (INIS)

    Pinto, N.; Braz, D.; Lopes, R.; Vallim, M.; Padilha, L.; Azevedo, F.; Barroso, R.

    2006-01-01

    Values of absorbed dose taken by patients and professionals involved in interventional radiology can be significant mainly for the reason of these proceedings taking long time of fluoroscopy There are many methods to estimate and reduce doses of radiation in the interventional radiology, particularly because the fluoroscopy is responsible for the high dose contribution in the patient and in the professional. The aim of this work is the thermoluminescent dosimetry to estimate the dose values of the extremities of the professionals involved in the interventional radiology and the product dose-area was investigated using a Diamentor. This evaluation is particularly useful for proceedings that interest multiple parts of the organism. In this study were used thermoluminescent dosimeters (LiF:Mg, Ti - Harshaw) to estimate the dose values of the extremities of the professionals and to calibrate them. They were irradiated with X rays at 50 mGy, in Kerma in air and read in the reader Harshaw-5500. The product dose-area (D.A.P.) were obtained through the Diamentor (M2-P.T.W.) calibrated in Cgy.cm 2 fixed in the exit of the X-rays tube. The patients of these study were divided in three groups: individuals submitted to proceedings of embolization, individuals submitted to cerebral and renal arteriography and individuals submitted to proceedings of Transjungular Inthahepatic Porta Systemic Stent Shunt (TIPS). The texts were always carried out by the same group: radiologist doctor), an auxiliary doctor and a nursing auxiliary. The section of interventional radiology has an Angiostar Plus Siemens equipment type arc C, in which there is trifocal Megalix X-ray tube and a intensifier of image from Sirecon 40-4 HDR/33 HDR. In this work the dose estimated values were 137.25 mSv/year for the doctors, 40.27 mSv/year for the nursing and 51.95 mSv/year for the auxiliary doctor and they are below the rule, but in this study it was not taken in consideration the emergency texts as they were

  12. Cytogenetic biological dosimetry. Dose estimative in accidental exposure

    International Nuclear Information System (INIS)

    Santos, O.R. dos; Campos, I.M.A. de.

    1988-01-01

    The methodology of cytogenetic biological dosimetry is studied. The application in estimation of dose in five cases of accidental exposure is reported. An hematological study and culture of lymphocytes is presented. (M.A.C.) [pt

  13. Estimation of the fetal dose by dose measurement during an irradiation of a parotid tumor; Estimation de la dose foetale par mesure de dose lors d'une irradiation d'une tumeur de la parotide

    Energy Technology Data Exchange (ETDEWEB)

    Marchesi, V.; Graff-Cailleaud, P.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Noel, A. [Institut National Polytechnique de Lorraine, CRAN CNRS UMR-7039, 54 - Vandoeuvre-les-Nancy (France)

    2006-11-15

    The irradiation of a five months pregnant patient has been made for a right parotid attack. In conformation with the legislative texts relative to radiation protection ( publication 84 of the ICRP) an estimation of the dose received for the fetus has been led by dose measurement on phantom. With the dose limit ( 100 mGy) recommended in the publication 84 of the ICRP neither modification of the treatment nor abortion was necessary. (N.C.)

  14. Estimating dose rates to organs as a function of age following internal exposure to radionuclides

    International Nuclear Information System (INIS)

    Leggett, R.W.; Eckerman, K.F.; Dunning, D.E. Jr.; Cristy, M.; Crawford-Brown, D.J.; Williams, L.R.

    1984-03-01

    The AGEDOS methodology allows estimates of dose rates, as a function of age, to radiosensitive organs and tissues in the human body at arbitrary times during or after internal exposure to radioactive material. Presently there are few, if any, radionuclides for which sufficient metabolic information is available to allow full use of all features of the methodology. The intention has been to construct the methodology so that optimal information can be gained from a mixture of the limited amount of age-dependent, nuclide-specific data and the generally plentiful age-dependent physiological data now available. Moreover, an effort has been made to design the methodology so that constantly accumulating metabolic information can be incorporated with minimal alterations in the AGEDOS computer code. Some preliminary analyses performed by the authors, using the AGEDOS code in conjunction with age-dependent risk factors developed from the A-bomb survivor data and other studies, has indicated that the doses and subsequent risks of eventually experiencing radiogenic cancers may vary substantially with age for some exposure scenarios and may be relatively invariant with age for other scenarios. We believe that the AGEDOS methodology provides a convenient and efficient means for performing the internal dosimetry

  15. Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Kumamoto, Yoshikazu; Noda, Yutaka; Nishizawa, Kanae; Furuya, Yoshiro; Iwai, Kazuo.

    1988-01-01

    Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10 3 for men and 36.3 x 10 3 for women, with a total of 38.9 x 10 3 . The annual frequencies of using afterloading technique were 0.3 x 10 3 for men and 18.8 x 10 3 for women, with a total of 19.1 x 10 3 . The annual population doses per person were 7.9 nGy for GSD, 118 μGy for CMD, 19.3 μGy for LSD, 172 μGy for MSD, and 428 μGy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10 4 man Sv. (Namekawa, K.)

  16. Estimated collective effective dose to the population from nuclear medicine examinations in Slovenia

    International Nuclear Information System (INIS)

    Skrk, Damijan; Zontar, Dejan

    2013-01-01

    A national survey of patient exposure from nuclear medicine diagnostic procedures was performed by Slovenian Radiation Protection Administration in order to estimate their contribution to the collective effective dose to the population of Slovenia. A set of 36 examinations with the highest contributions to the collective effective dose was identified. Data about frequencies and average administered activities of radioisotopes used for those examinations were collected from all nuclear medicine departments in Slovenia. A collective effective dose to the population and an effective dose per capita were estimated from the collected data using dose conversion factors. The total collective effective dose to the population from nuclear medicine diagnostic procedures in 2011 was estimated to 102 manSv, giving an effective dose per capita of 0.05 mSv. The comparison of results of this study with studies performed in other countries indicates that the nuclear medicine providers in Slovenia are well aware of the importance of patient protection measures and of optimisation of procedures

  17. Entrances skin dose distribution maps for interventional neuroradiological procedures: A preliminary study

    International Nuclear Information System (INIS)

    Rampado, O.; Ropolo, R.

    2005-01-01

    Does estimation in interventional neuroradiology can be useful to limit skin radiation injuries. The purpose of this study was to evaluate the role of entrance skin dose (ESD) maps in planning exposure condition optimisation. Thirteen cerebral angiography and five embolisation procedures were monitored, measuring ESD, dose-area product (DAP) and other operational parameters. A transmission ionisation chamber, simultaneously measuring air kerma and DAP, measured dose-related quantities. Data acquisition software collected dosimetric and geometrical data during the interventional procedure and provided a distribution map of ESD on a standard phantom digital image, with maximum value estimation. Values of 88-1710 mGy for maximum skin dose and 16.7-343 Gy cm 2 for DAP were found. These data confirm the possibility of deterministic effects during therapeutic interventional neuroradiological procedures like cerebral embolisation. ESD maps are useful to retrospectively study the exposure characteristics of a procedure and plan patient exposure optimisation. (authors)

  18. Necessary accuracy of dose estimation during cohort epidemiologic study after irradiation

    International Nuclear Information System (INIS)

    Orlov, M.Yu.; Stepanenko, V.F.; Khoshi, M.; Takada, Dzh.

    2003-01-01

    Effect of breadth of dose ranges on values of radiation risk was estimated. Ratios of observed numbers of mortalities because of leukemia in the cohort in 1950 - 1974 under deferent radiation dose to expected number of mortalities in this cohort only under background radiation were used as degree of risk. Data of cooperative Japan-American Program LSS (Life Span Study) were applied in the researches. It is established that required for the risk assessment with uncertainty 20 - 30 % the accuracy of dose estimation comprises 30 - 35 % in the range 1 - 5 rad and 5 - 10 % in the range 5 - 30 rad [ru

  19. System for estimation of mean active bone marrow dose

    International Nuclear Information System (INIS)

    Ellis, R.E.; Healy, M.J.R.; Shleien, B.; Tucker, T.

    1975-09-01

    The exposure measurements, model and computer program for estimation of mean active bone marrow doses formerly employed in the 1962 British Survey of x-ray doses and proposed for application to x-ray exposure information obtained in the U.S. Public Health Service's X-Ray Exposure Studies (1966 and 1973) are described and evaluated. The method described is feasible for use to determine the mean active bone marrow doses to adults for examinations having a skin to source distance of 80 cm or less. For a greater SSD, as for example in chest x rays, a small correction in the calculation dose can be made

  20. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  1. Noise and dose modeling for pediatric CT optimization: preliminary results

    International Nuclear Information System (INIS)

    Miller Clemente, Rafael A.; Perez Diaz, Marlen; Mora Reyes, Yudel; Rodriguez Garlobo, Maikel; Castillo Salazar, Rafael

    2008-01-01

    Full text: A Multiple Linear Regression Model was developed to predict noise and dose in computed tomography pediatric imaging for head and abdominal examinations. Relative values of Noise and Volumetric Computed Tomography Dose Index was used to estimate de model respectively. 54 images of physical phantoms were performed. Independent variables considered included: phantom diameter, tube current and kilovolts, x ray beam collimation, reconstruction diameter and equipment's post processing filters. Predicted values show good agreement with measurements, which were better in noise model (R 2 adjusted =0.953) than the dose model (R 2 adjusted =0.744). Tube current, object diameter, beam collimation and reconstruction filter were identified as the most influencing factors in models. (author)

  2. Estimating adolescent sleep need using dose-response modeling.

    Science.gov (United States)

    Short, Michelle A; Weber, Nathan; Reynolds, Chelsea; Coussens, Scott; Carskadon, Mary A

    2018-04-01

    This study will (1) estimate the nightly sleep need of human adolescents, (2) determine the time course and severity of sleep-related deficits when sleep is reduced below this optimal quantity, and (3) determine whether sleep restriction perturbs the circadian system as well as the sleep homeostat. Thirty-four adolescents aged 15 to 17 years spent 10 days and nine nights in the sleep laboratory. Between two baseline nights and two recovery nights with 10 hours' time in bed (TIB) per night, participants experienced either severe sleep restriction (5-hour TIB), moderate sleep restriction (7.5-hour TIB), or no sleep restriction (10-hour TIB) for five nights. A 10-minute psychomotor vigilance task (PVT; lapse = response after 500 ms) and the Karolinska Sleepiness Scale were administered every 3 hours during wake. Salivary dim-light melatonin onset was calculated at baseline and after four nights of each sleep dose to estimate circadian phase. Dose-dependent deficits to sleep duration, circadian phase timing, lapses of attention, and subjective sleepiness occurred. Less TIB resulted in less sleep, more lapses of attention, greater subjective sleepiness, and larger circadian phase delays. Sleep need estimated from 10-hour TIB sleep opportunities was approximately 9 hours, while modeling PVT lapse data suggested that 9.35 hours of sleep is needed to maintain optimal sustained attention performance. Sleep restriction perturbs homeostatic and circadian systems, leading to dose-dependent deficits to sustained attention and sleepiness. Adolescents require more sleep for optimal functioning than typically obtained.

  3. Maxine: A spreadsheet for estimating dose from chronic atmospheric radioactive releases

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, Tim [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Bell, Evaleigh [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, Kenneth [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-24

    MAXINE is an EXCEL© spreadsheet, which is used to estimate dose to individuals for routine and accidental atmospheric releases of radioactive materials. MAXINE does not contain an atmospheric dispersion model, but rather doses are estimated using air and ground concentrations as input. Minimal input is required to run the program and site specific parameters are used when possible. Complete code description, verification of models, and user’s manual have been included.

  4. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  5. Survey of pediatric MDCT radiation dose from university hospitals in Thailand. A preliminary for national dose survey

    Energy Technology Data Exchange (ETDEWEB)

    Kritsaneepaiboon, Supika [Dept. of Radiology, Faculty of Medicine, Prince of Songkla Univ., Hat Yai (Thailand)], e-mail: supikak@yahoo.com; Trinavarat, Panruethai [Dept. of Radiology, Faculty of Medicine, Chulalongkorn Univ., Bangkok (Thailand); Visrutaratna, Pannee [Dept. of Radiology, Faculty of Medicine, Chiang Mai Univ., Chiang Mai (Thailand)

    2012-09-15

    Background: Increasing pediatric CT usage worldwide needs the optimization of CT protocol examination. Although there are previous published dose reference level (DRL) values, the local DRLs should be established to guide for clinical practice and monitor the CT radiation. Purpose: To determine the multidetector CT (MDCT) radiation dose in children in three university hospitals in Thailand in four age groups using the CT dose index (CTDI) and dose length product (DLP). Material and Methods: A retrospective review of CT dosimetry in pediatric patients (<15 years of age) who had undergone head, chest, and abdominal MDCT in three major university hospitals in Thailand was performed. Volume CTDI (CTDIvol) and DLP were recorded, categorized into four age groups: <1 year, 1- < 5 years, 5- <10 years, and 10- <15 years in each scanner. Range, mean, and third quartile values were compared with the national reference dose levels for CT in pediatric patients from the UK and Switzerland according to International Commission on Radiological Protection (ICRP) recommendation. Results: Per age group, the third quartile values for brain, chest, and abdominal CTs were, respectively, in terms of CTDIvol: 25, 30, 40, and 45 mGy; 4.5, 5.7, 10, and 15.6 mGy; 8.5, 9, 14, and 17 mGy; and in terms of DLP: 400, 570, 610, and 800 mGy cm; 80, 140, 305, and 470 mGy cm; and 190, 275, 560,765 mGy cm. Conclusion: This preliminary national dose survey for pediatric CT in Thailand found that the majority of CTDIvol and DLP values in brain, chest, and abdominal CTs were still below the diagnostic reference levels (DRLs) from the UK and Switzerland regarding to ICRP recommendation.

  6. Estimation of organ and effective dose due to Compton backscatter security scans

    International Nuclear Information System (INIS)

    Hoppe, Michael E.; Schmidt, Taly Gilat

    2012-01-01

    Purpose: To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. Methods: Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was modeled based on specifications available in the literature. The simulations modeled a 50 kVp spectrum with 1.0 mm-aluminum-equivalent filtration and a previously measured exposure of approximately 4.6 μR at 30 cm from the source. Photons and secondary interactions were tracked from the source until they reached zero kinetic energy or exited from the simulation’s boundaries. The energy deposited in the phantoms’ respective organs was tallied and used to calculate total organ dose and total effective dose for frontal, rear, and full scans with subjects located 30 and 75 cm from the source. Results: For a full screen, all phantoms’ total effective doses were below the established 0.25 μSv standard, with an estimated maximum total effective dose of 0.07 μSv for full screen of a male child. The estimated maximum organ dose due to a full screen was 1.03 μGy, deposited in the adipose tissue of the male child phantom when located 30 cm from the source. All organ dose estimates had a coefficient of variation of less than 3% for a frontal scan and less than 11% for a rear scan. Conclusions: Backscatter security scanners deposit dose in organs beyond the skin. The effective dose is below recommended standards set by the Health Physics Society (HPS) and the American National Standards Institute (ANSI) assuming the system provides a maximum exposure of approximately 4.6 μR at 30 cm.

  7. Columbia River pathway report: phase I of the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    1991-07-01

    This report summarizes the river-pathway portion of the first phase of the Hanford Environmental Dose Reconstruction (HEDR) Project. The HEDR Project is estimating radiation doses that could have been received by the public from the Department of Energy's Hanford Site, in southeastern Washington State. Phase 1 of the river-pathway dose reconstruction effort sought to determine whether dose estimates could be calculated for populations in the area from above the Hanford Site at Priest Rapids Dam to below the site at McNary Dam from January 1964 to December 1966. Of the potential sources of radionuclides from the river, fish consumption was the most important. Doses from drinking water were lower at Pasco than at Richland and lower at Kennewick than at Pasco. The median values of preliminary dose estimates calculated by HEDR are similar to independent, previously published estimates of average doses to Richland residents. Later phases of the HEDR Project will address dose estimates for periods other than 1964--1966 and for populations downstream of McNary Dam. 17 refs., 19 figs., 1 tab.

  8. Phantom measurements and computed estimates of breast dose with radiotherapy for Hodgkin's lymphoma: dose reduction with the use of the involved field

    International Nuclear Information System (INIS)

    Wirth, A.; Kron, T.; Sorell, G.; Cramb, J.; Wittwer, H.; Sullivan, K.

    2008-01-01

    Full text: The risk of breast cancer following radiotherapy for Hodgkin's lymphoma appears to be dose related. In this study we compared breast dose in an anthropomorphic phantom for conventional 'mantle'; upper mediastinal/bilateral neck (minimantle) and unilateral neck fields, and evaluated the accuracy of computer planned dose estimates for out-of-field doses. For each field, computer-planned breast dose (CPD) estimates were compared with thermolu-minescence dosimetry measurements in five locations within 'breast tissue'. CPD were also compared with ion chamber measurements in a slab phantom. Measured dose and CPD were within 20% of each other up to approximately 10 cm from the field edge. Beyond 10 cm, the CPD underestimated dose by a factor of 2 or more. The minimantle reduced the breast dose by a factor of approximately 10 compared with the mantle treatment. Treating the neck field lowered the breast dose by a further 50% or more. Modern involved-field radiotherapy for lymphoma substantially reduces breast dose compared with mantle fields. Computer dosimetery underestimated dose at larger distances from the field. This needs to be considered if computer dosimetery is used to estimate breast dose and, by extrapolation, breast cancer risk.

  9. Dose-response curve estimation: a semiparametric mixture approach.

    Science.gov (United States)

    Yuan, Ying; Yin, Guosheng

    2011-12-01

    In the estimation of a dose-response curve, parametric models are straightforward and efficient but subject to model misspecifications; nonparametric methods are robust but less efficient. As a compromise, we propose a semiparametric approach that combines the advantages of parametric and nonparametric curve estimates. In a mixture form, our estimator takes a weighted average of the parametric and nonparametric curve estimates, in which a higher weight is assigned to the estimate with a better model fit. When the parametric model assumption holds, the semiparametric curve estimate converges to the parametric estimate and thus achieves high efficiency; when the parametric model is misspecified, the semiparametric estimate converges to the nonparametric estimate and remains consistent. We also consider an adaptive weighting scheme to allow the weight to vary according to the local fit of the models. We conduct extensive simulation studies to investigate the performance of the proposed methods and illustrate them with two real examples. © 2011, The International Biometric Society.

  10. A study on pre-heat conditions in equivalent-dose estimation of holocene loess using single-aliquot regenerative-dose (SAR) protocol

    International Nuclear Information System (INIS)

    Jia Yaofeng; Huang Chunchang; Pang Jiangli; Lu Xinwei; Zhang Xu

    2007-01-01

    Through various arrangements of pre-heat and cut-heat temperatures in the equivalent-dose estimation of Holocene loess using a Double-SAR dating protocol, the paper estimated the equivalent-doses from several loess samples by application of IRSL and Post-IR OSL signals, respectively. The measured results present that the equivalent-dose depends on the heat temperature, especially depends on the cut-heat temperature, showing the equivalent-dose increases with the cut-heat temperature; a plateau of equivalent-dose appears at the 200-300 degree C preheat temperatures and the 200-240 degree C cut-heat temperatures, furthermore, the equivalent-doses estimated by IRSL and Post-IR OSL signals respectively are close to each other, which resulted from the similar sensitivity change directions of optical stimulated signals and their smaller change ranges in the measurement cycles using the various temperatures of pre-heat and cut-heat. This suggests that the 200-300 degree C pre-heat temperatures and the 200-240 degree C cut-heat temperatures are fit for dating young Holocene loess samples. (authors)

  11. A PC program for estimating organ dose and effective dose values in computed tomography

    International Nuclear Information System (INIS)

    Kalender, W.A.; Schmidt, B.; Schmidt, M.; Zankl, M.

    1999-01-01

    Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned. (orig.)

  12. Estimation of dose in dental radiology exams in critical regions

    International Nuclear Information System (INIS)

    Bonzoumet, S.P.J.; Braz, D.; Padilha, Lucas

    2005-01-01

    The objective of this paper is to estimate the values of doses, which are absorbed dose to the lens and thyroid in a dental X-ray. Thermoluminescence dosimeters were used, once they provide a reading of quality and effectiveness. This study was based on dental exams conducted in patients in order to estimate the dose that disperses to the lens of the eye and for the thyroid during an intraoral exam. Data collection took place in two institutions, one governmental, which had the device SELETRONIC 70X and other particular. This study showed that there is a considerable variation between the appliances. Using the appliance DABI 1070, there was a greater absorption of radiation in the right eye (values greater than 5 mGy) and a lower dose in the thyroid, and the Seletronic 70X presented an incidence of higher dose deposited in the skin and in other points there was a balance in the values. In the appliance SELETRONIC 70X, there was again a greater absorption of radiation in the right eye and a lower setting in the thyroid. The excessive dose, besides does not favor at all for the quality of radiograph, represents a risk for the patient who absorbs unnecessary and harmful radiation to the body

  13. Estimation of foetal brain dose from I-131 in the foetal thyroid

    International Nuclear Information System (INIS)

    O'Hare, N.J.; Murphy, D.; Malone, J.F.; Gilligan, P.

    1997-01-01

    The ingestion of I-131 by pregnant women can have consequences for the developing foetus, in particular brain function. As the foetal thyroid accumulates iodine from the twelfth week of gestation onwards, the determination of foetal brain dose resulting from such I-131 accumulation is essential. Normal dosimetric methods fail to treat the case of the foetus. Using an approximation method based on the MIRD approach, a foetal dose estimation scheme is developed to allow the determination of foetal brain dose from foetal thyroid irradiation. Dose values are obtained for the foetus based on the maternal intake of I-131. It was found that the choice of biokinetic model for the mother/foetus has a large impact on the determined dose estimate. (author)

  14. Uncertainties in estimating heart doses from 2D-tangential breast cancer radiotherapy

    DEFF Research Database (Denmark)

    Laugaard Lorenzen, Ebbe; Brink, Carsten; Taylor, Carolyn W.

    2016-01-01

    BACKGROUND AND PURPOSE: We evaluated the accuracy of three methods of estimating radiation dose to the heart from two-dimensional tangential radiotherapy for breast cancer, as used in Denmark during 1982-2002. MATERIAL AND METHODS: Three tangential radiotherapy regimens were reconstructed using CT......-based planning scans for 40 patients with left-sided and 10 with right-sided breast cancer. Setup errors and organ motion were simulated using estimated uncertainties. For left-sided patients, mean heart dose was related to maximum heart distance in the medial field. RESULTS: For left-sided breast cancer, mean...... to the uncertainty of estimates based on individual CT-scans. For right-sided breast cancer patients, mean heart dose based on individual CT-scans was always

  15. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2009-01-01

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  16. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E. [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia 5000 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Division of Medical Imaging, Women' s and Children' s Hospital, North Adelaide, South Australia 5006 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia)

    2009-09-15

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  17. GARDEC, Estimation of dose-rates reduction by garden decontamination

    International Nuclear Information System (INIS)

    Togawa, Orihiko

    2006-01-01

    1 - Description of program or function: GARDEC estimates the reduction of dose rates by garden decontamination. It provides the effect of different decontamination Methods, the depth of soil to be considered, dose-rate before and after decontamination and the reduction factor. 2 - Methods: This code takes into account three Methods of decontamination : (i)digging a garden in a special way, (ii) a removal of the upper layer of soil, and (iii) covering with a shielding layer of soil. The dose-rate conversion factor is defined as the external dose-rate, in the air, at a given height above the ground from a unit concentration of a specific radionuclide in each soil layer

  18. Analysis of data on radon monitoring and dose estimates for uranium mines

    International Nuclear Information System (INIS)

    Khan, A.H.; Srivastava, G.K.; Jha, Shankar; Sagar, D.V.

    1994-01-01

    Radon progeny are the major contributors to the radiation dose to uranium miners. Monitoring for radon and gamma radiation is an integral part of radiation protection in such mines. Data for equilibrium equivalent radon and the estimated mean annual doses are presented in this paper for Jaduguda uranium mine from 1986 to 1992. The 1992 data for Jaduguda and Bhatin mines are compared. The average annual effective dose for uranium miners is estimated at around 15.5 mSv. (author). 1 ref., 2 figs

  19. External dose estimates for future Bikini Atoll inhabitants

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Crites, T.R.; Robison, W.L.

    1976-01-01

    To evaluate the potential radiation doses that may be received by the returning Bikinians, we surveyed the residual radioactivity on Bikini and Eneu Islands in June of 1975. An integral part of the survey included measurements of gamma-ray exposure rates which are used to estimate external gamma-ray doses. The survey showed that on Bikini Island the rates are highly variable: values near the shores are generally of the order of 10 to 20 μR/h, while those within the interior average about 40 μR/h with a range of roughly 30 to 100 μR/h. Eneu Island, however, is characterized by more or less uniformly distributed gamma radiation levels of less than 10 μR/h over the entire island. These data, in conjunction with population statistics and expected life styles, allowed us to estimate the potential external gamma-ray doses associated with proposed housing locations along the lagoon road and within the interior portions of Bikini Island as well as along the lagoon side of Eneu Island. As expected, living on Eneu Island results in the lowest doses: 0.12 rem during the first year and 2.9 rem during 30 years. The highest values, 0.28 rem during the first year and 5.9 rem over 30 years, may potentially be received by inhabitants living within the interior of Bikini Island. Other options under consideration produce intermediate values

  20. Solid Waste Operations Complex W-113: Project cost estimate. Preliminary design report. Volume IV

    International Nuclear Information System (INIS)

    1995-01-01

    This document contains Volume IV of the Preliminary Design Report for the Solid Waste Operations Complex W-113 which is the Project Cost Estimate and construction schedule. The estimate was developed based upon Title 1 material take-offs, budgetary equipment quotes and Raytheon historical in-house data. The W-113 project cost estimate and project construction schedule were integrated together to provide a resource loaded project network

  1. Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

    International Nuclear Information System (INIS)

    Norris, Edward T.; Liu, Xin; Hsieh, Jiang

    2015-01-01

    Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer

  2. The estimation of effective doses using measurement of several relevant physical parameters from radon exposures

    International Nuclear Information System (INIS)

    Ridzikova, A; Fronka, A.; Maly, B.; Moucka, L.

    2003-01-01

    In the present investigation, we will be study the dose relevant factors from continual monitoring in real homes into account getting more accurate estimation of 222 Rn the effective dose. The dose relevant parameters include the radon concentration, the equilibrium factor (f), the fraction (fp) of unattached radon decay products and real time occupancy people in home. The result of the measurement are the time courses of radon concentration that are based on estimation effective doses together with assessment of the real time occupancy people indoor. We found out by analysis that year effective dose is lower than effective dose estimated by ICRP recommendation from the integral measurement that included only average radon concentration. Our analysis of estimation effective doses using measurement of several physical parameters was made only in one case and for the better specification is important to measure in different real occupancy houses. (authors)

  3. Development of mathematical model for estimation of entrance surface dose in mammography

    International Nuclear Information System (INIS)

    Abdelgani, Yassir Mohammed Tahir

    2013-05-01

    Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy rang from 18 keV to 40 ke V has been developed by Boone et al. Due to the lack of QC and dose measurement tools, in addition to unavailability of medical physics, a mathematical tool was developed for estimation of patient exposure and entrance dose. The proposed model require no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally by John M Boone (Department of Radiology, University of California). Using experimental dose measurements for specific tube voltage and tube current the generated x-ray spectra were calibrated. The spectrum calibration factors show a tube voltage dependency. From the calibrated x-ray spectrum, the exposure and entrance dose were estimated for different k Vp and m A. Results show good agreement between the measured and estimated values for tube voltage between 18 to 45 k Vp with a good correlation of nearly 1 and equal slope. The maximum estimated different between the measured and the simulated dose is approximately equal to 0.07%.(Author)

  4. Revision of risk estimates and implications for dose limits

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1989-01-01

    It has been apparent for some time that our estimates of the risks associated with exposure to ionizing radiation must be increased above those values reported by UNSCEAR in 1977 an dused by ICRP to form their present recommendations. NRPB foresaw some of these changes and introduced interim advice within the UK to restrict exposures of wordkers and members of the public to levels below the existing limits. Since that advice was given, UNSCEAR has produced a 1988 report reviewing human data to provide new estimates of risks associated with exposure at high doses and high doserates. These risk figures are up to 4 times higher than when UNSCEAR reported in 1977. In this paper, the reasons for the changes in the estimates of risk will be described and the current NRPB guidelines for risk factors for protection purposes will be presented. The implications of these new risk factors for the setting of dose limits will then be discussed. (Author). 10 refs.; 2 tabs

  5. The study on pre-heat conditions in the equivalent-dose estimation of holocene loess using the single-aliquot regenerative-dose (SAR) protocol

    International Nuclear Information System (INIS)

    Jia Yaofeng; Huang Chunchang; Pang Jiangli; Lu Xinwei; Zhang Xu

    2008-01-01

    The thermal treatment in the equivalent-dose estimation often is carried in the OSL dating, and pre-heat is a main thermal treatment. Due to which will originate the problems of thermal transfer and thermal activation, the thermal treatment and the setup of their conditions are key problems influencing the accuracy of OSL dating. The paper combined the temperature of pre-heat and cut-heat used in the routine measurement of IRSL and Post-IR OSL, and then estimated the equivalent-dose of several loess samples. The estimated result presents that the equivalent-dose depends on the heat temperature, especially depends on the cut-heat temperature, which is to say that the equivalent-dose increases with the cut-heat temperature; a plateau of equivalent-dose appears when using the 200-240 degree C cut-heat in the range of 200-300 degree C pre-heat, and the equivalent-doses estimated by IRSL and Post-IR OSL respectively are close to each other, which resulted from the similar sensitivity change direction of optical stimulated signals and its smaller change range in the measurement cycles using the combined temperature of pre- heat and cut-heat, and the incomplete calibration of sensitivity change of optical stimulated signals in the whole measurement cycles caused the variation of estimated equivalent-dose corresponding to the cut-heat temperature. (authors)

  6. Okadaic acid for radiation dose estimation using drug-induced premature chromosome condensation

    International Nuclear Information System (INIS)

    Wang Chunyan; Zhang Wei; Su Xu

    2005-01-01

    Objective: To establish simple biological method for high irradiation dose estimation using drug-induced prematurely condensed chromosomes (PCC) aberrations. Methods: Peripheral blood was taken from healthy adults and irradiated by 0, 1, 2, 5, 10, 15, 20 and 25 Gy 60 Co γ-rays. Then the blood samples were cultured for 48 hrs. One hr before the end of culture , okadaic acid was added into culture medium to induce PCC rings, which were counted for each dose point. Results: The yield of PCC rings was increased with the dose of radiation until 20 Gy. Within the range of 1 to 20 Gy, there was a good dose-response relationship between the yield of PCC rings and radiation dose. Conclusion: Compared with the analysis of frequency of dicentrics, the yield of PCC rings could be a good biodosimetry indicator for estimation of high dose irradiation. (authors)

  7. Estimation of eye absorbed doses in head & neck radiotherapy practices using thermoluminescent detectors

    Directory of Open Access Journals (Sweden)

    Gh Bagheri

    2011-09-01

    Full Text Available  Determination of eye absorbed dose during head & neck radiotherapy is essential to estimate the risk of cataract. Dose measurements were made in 20 head & neck cancer patients undergoing 60Co radiotherapy using LiF(MCP thermoluminescent dosimeters. Head & neck cancer radiotherapy was delivered by fields using SAD & SSD techniques. For each patient, 3 TLD chips were placed on each eye. Head & neck dose was about 700-6000 cGy in 8-28 equal fractions. The range of eye dose is estimated to be (3.49-639.1 mGy with a mean of maximum dose (98.114 mGy, which is about 3 % of head & neck dose. Maximum eye dose was observed for distsnces of about 3 cm from edge of the field to eye.

  8. Estimation of absorbed dose by newborn patients subjected to chest radiographs

    International Nuclear Information System (INIS)

    Bunick, Ana P.; Schelin, Hugo R.; Denyak, Valeriy

    2016-01-01

    The aim of this study is to present an estimate of the effective dose received by newborn patients hospitalized in NICU and subjected to X-ray examinations of the chest in the AP projection. Initially, were followed examinations chest X-rays performed on newborn patients and subsequently, simulated in a newborn simulator object. The ESAK values obtained by TLDs were used to calculate the effective dose obtained at each examination by Caldose_X software. The estimated values for the effective dose in the simulated exams in this study range from 2,3μSv the 10,7μSv. The results achieved are, generally, inferior to those reported for similar previous studies. (author)

  9. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  10. Estimation of effective doses in pediatric X-ray computed tomography examination.

    Science.gov (United States)

    Obara, Hideki; Takahashi, Midori; Kudou, Kazuya; Mariya, Yasushi; Takai, Yoshihiro; Kashiwakura, Ikuo

    2017-11-01

    X-ray computed tomography (CT) images are used for diagnostic and therapeutic purposes in various medical disciplines. In Japan, the number of facilities that own diagnostic CT equipment, the number of CT examinations and the number of CT scanners increased by ~1.4-fold between 2005 and 2011. CT operators (medical radiological technologists, medical physicists and physicians) must understand the effective doses for examinations at their own institutions and carefully approach each examination. In addition, the patients undergoing the examination (as well as his/her family) must understand the effective dose of each examination in the context of the cumulative dose. In the present study, the numbers of pediatric patients (aged 0-5 years) and total patients who underwent CT at Hirosaki University Hospital (Hirosaki, Japan) between January 2011 and December 2013 were surveyed, and effective doses administered to children aged 0, 1 and 5 years were evaluated. Age- and region-specific conversion factors and dose-length products obtained from the CT scanner were used to estimate the effective doses. The numbers of CT examinations performed in 2011, 2012 and 2013 were 16,662, 17,491 and 17,649, respectively, of which 613 (1.2%) of the overall total involved children aged 0-5 years. The estimated effective doses per examination to children aged 0, 1 and 5 years were 6.3±4.8, 4.9±3.8 and 2.7±3.0 mSv, respectively. This large variation was attributed to several factors associated with scan methods and ranges in actual setting. In conclusion, the requirement for individual patient prospective exposure management systems and estimations of low-dose radiation exposure should be considered in light of the harmful effects of exposure.

  11. Simple approximation for estimating centerline gamma absorbed dose rates due to a continuous Gaussian plume

    International Nuclear Information System (INIS)

    Overcamp, T.J.; Fjeld, R.A.

    1987-01-01

    A simple approximation for estimating the centerline gamma absorbed dose rates due to a continuous Gaussian plume was developed. To simplify the integration of the dose integral, this approach makes use of the Gaussian cloud concentration distribution. The solution is expressed in terms of the I1 and I2 integrals which were developed for estimating long-term dose due to a sector-averaged Gaussian plume. Estimates of tissue absorbed dose rates for the new approach and for the uniform cloud model were compared to numerical integration of the dose integral over a Gaussian plume distribution

  12. Radiation dose estimates for copper-64 citrate in man

    International Nuclear Information System (INIS)

    Crook, J.E.; Carlton, J.E.; Stabin, M.; Watson, E.

    1985-01-01

    Tumor imaging agents suitable for use with positron emission tomographs are constantly sought. We have performed studies with animal-tumor-bearing models that have demonstrated the rapid uptake of copper-64. The radiation dose estimates for man indicate that the intravenous administration of 7.0 mCi would result in radiation doses to the kidney of 9.8 to 10.5 rads with other organs receiving substantially less radiation. 5 refs., 3 tabs

  13. Radiation dose estimates for copper-64 citrate in man

    International Nuclear Information System (INIS)

    Crook, J.E.; Carlton, J.E.; Stabin, M.; Watson, E.

    1986-01-01

    Tumor imaging agents suitable for use with positron emission tomographs are constantly sought. The authors have performed studies with animal-tumor-bearing models that have demonstrated the rapid uptake of copper-64. The radiation dose estimates for man indicate that the intravenous administration of 7.0 mCi would result in radiation doses to the kidney of 9.8 to 10.5 rads with other organs receiving substantially less radiations. 5 references, 3 tables

  14. Dose estimation of interventional cardiologists in different body regions

    International Nuclear Information System (INIS)

    Borba, Iana Q. de; Luz, Renata M. da; Capaverde, Alexandre S.; Silva, Ana M. Marques da; Caramori, Paulo Ricardo Avancini

    2015-01-01

    Interventional radiology is one of the medical specialties that provides the highest doses to professionals, widely used in cardiology, being called interventional cardiology. In order to contribute to the optimization of occupational radiation protection in interventional cardiology procedures, the aim of this study is to evaluate the dose estimation received in different body regions by physicians in interventional cardiology procedures. Two physicians were followed, named as A and B, during one month period, performing a total of 127 procedures (70 for A and 57 for B) of interventional cardiology. During the procedures, dosimeters in different body regions beyond the full-body dosimeter were positioned. The results showed the highest values for the estimated dose received by workers were in the right wrist and left side face regions, for the physician A, and in the left knee and left side face, for the physician B. Results demonstrate the importance of using individual protection equipment by physicians in interventional cardiology, including lead glasses, besides monitoring dosimeters for other body regions, such as wrist, face and knee. (author)

  15. Estimation of the collective dose in the Portuguese population due to medical procedures in 2010

    International Nuclear Information System (INIS)

    Teles, Pedro; Vaz, Pedro; Sousa, M. Carmen de; Paulo, Graciano; Santos, Joana; Pascoal, Ana; Cardoso, Gabriela; Santos, Ana Isabel; Lanca, Isabel; Matela, Nuno; Janeiro, Luis; Sousa, Patrick; Carvoeiras, Pedro; Parafita, Rui; Simaozinho, Paula

    2013-01-01

    In a wide range of medical fields, technological advancements have led to an increase in the average collective dose in national populations worldwide. Periodic estimations of the average collective population dose due to medical exposure is, therefore of utmost importance, and is now mandatory in countries within the European Union (article 12 of EURATOM directive 97/ 43). Presented in this work is a report on the estimation of the collective dose in the Portuguese population due to nuclear medicine diagnostic procedures and the Top 20 diagnostic radiology examinations, which represent the 20 exams that contribute the most to the total collective dose in diagnostic radiology and interventional procedures in Europe. This work involved the collaboration of a multidisciplinary taskforce comprising representatives of all major Portuguese stakeholders (universities, research institutions, public and private health care providers, administrative services of the National Healthcare System, scientific and professional associations and private service providers). This allowed us to gather a comprehensive amount of data necessary for a robust estimation of the collective effective dose to the Portuguese population. The methodology used for data collection and dose estimation was based on European Commission recommendations, as this work was performed in the framework of the European wide Dose Datamed II project. This is the first study estimating the collective dose for the population in Portugal, considering such a wide national coverage and range of procedures and consisting of important baseline reference data. The taskforce intends to continue developing periodic collective dose estimations in the future. The estimated annual average effective dose for the Portuguese population was of 0.080±0.017 mSv caput -1 for nuclear medicine exams and of 0.96±0.68 mSv caput -1 for the Top 20 diagnostic radiology exams. (authors)

  16. SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

    International Nuclear Information System (INIS)

    Lin, P; Corwin, F; Ghita, M

    2016-01-01

    Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examination mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z

  17. SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

    Energy Technology Data Exchange (ETDEWEB)

    Lin, P; Corwin, F; Ghita, M [Virginia Commonwealth University Medical Center, Richmond, VA (United States)

    2016-06-15

    Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examination mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z

  18. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F., E-mail: falima@cnen.gov.br, E-mail: mendes_sb@hotmail.com [Centro Regional de Ciências Nucleares, (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Melo, Ana Maria M.A., E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Vitória de Santo Antão, PE (Brazil). Centro Acadêmico de Vitória

    2017-07-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  19. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    International Nuclear Information System (INIS)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F.; Melo, Ana Maria M.A.

    2017-01-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  20. Preliminary data on the effects of low radiation doses on plant life

    International Nuclear Information System (INIS)

    Fabries, M.; Grauby, A.

    1975-01-01

    The initial findings from the experimental low level irradiation of an ecosystem, with references to prior in this field, are studied. Previous research on low radiation doses of the University of Toulouse suggests that living organisms are in equilibrium with the radioactivity levels in their environment. Any decrease or increase in the natural radioactivity level seems to induce modifications in the microbe or plant population studies. The radioactivity level thus appears to be an ecological factor just as temperature, humidity, sunlight, etc... The preliminary experiments were conducted using an artificial radioactive source (Cesium-137) similar to sources likely in the future to cause increased environmental radioactivity from radioactive wastes and nuclear power plants. These experiments reveal an apparent reaction threshold of approximately 50μrad/hour among spontaneous plant populations. Above this dose the individuals show the effects of increased size, reduced size or both effects in turn (wave phenomenon) as the radiation level increases. It is difficult to come to any firm conclusions at the present time. Nevertheless, there seem to be a number of phenomena related to the increase in low level radiation doses. Some reflections on the behavior observed are offered [fr

  1. Estimation of internal dose from radiocesium and phantom

    International Nuclear Information System (INIS)

    Uchiyama, Masafumi; Nakamura, Yuji

    1994-01-01

    A complicated model describing the movement of a radionuclide in both the natural environment and socioeconomical systems is usually used to estimate the internal dose to the public in terms of collective dose, taking demographic data into account. The result can be certified for reliability in some compartments of the model. One of the compartments is the body content. In the case of radiocesium, the individual body burden can be measured using a whole-body counter. The measurement must be calibrated with a phantom. The public is composed of individuals of various ages. Accordingly, the whole-body counter should be calibrated with a set of phantoms approximating individuals of different body sizes. Relationships between counting efficiency and body size were analyzed on 137 Cs 134 Cs or 40 K incorporated into the whole-body using a set of phantoms. Four sizes covering average Japanese physiques from infant to adult male, were chosen to prepare an anthropomorphic phantom system. The distribution of 137 Cs in aquatic solution was homogeneous through the phantom. A whole-body counter at the National Institute of Radiological Sciences, was used at a rate of 5 cm per minute in a scanning mode. The measurements were carried out in an iron room. Relations were analyzed between counting efficiency and some anthropometric parameters. The best fit was given by a linear equation of both reciprocals of height in cm and weight in kg, with a correlation coefficient of 1.00 for 137 Cs. The result indicates that radioactivity of 137 Cs can be determined for individuals with different anthropometric parameters using the whole-body counter system. This means that effective equivalent doses for individuals can be computed accurately from the measurements. Further, an estimate on the body content from an dose estimation model using measurements of radioactivity in environmental substances can be evaluated by comparing the body burden measured. (J.P.N.)

  2. Cytogenetical dose estimation for 3 severely exposed patients in the JCO criticality accident in Tokai-mura

    International Nuclear Information System (INIS)

    Hayata, Isamu; Kanda, Reiko; Minamihisamatsu, Masako; Furukawa, Akira; Sasaki, Masao S.

    2001-01-01

    A dose estimation by chromosome analysis was performed on the 3 severely exposed patients in the Tokai-mura criticality accident. Drastically reduced lymphocyte counts suggested that the whole-body dose of radiation which they had been exposed to was unprecedentedly high. Because the number of lymphocytes in the white blood cells in two patients was very low, we could not culture and harvest cells by the conventional method. To collect the number of lymphocytes necessary for chromosome preparation, we processed blood samples by a modified method, called the high-yield chromosome preparation method. With this technique, we could culture and harvest cells, and then make air-dried chromosome slides. We applied a new dose-estimation method involving an artificially induced prematurely condensed ring chromosome, the PCC-ring method, to estimate an unusually high dose with a short time. The estimated doses by the PCC-ring method were in fairly good accordance with those by the conventional dicentric and ring chromosome (Dic + R) method. The biologically estimated dose was comparable with that estimated by a physical method. As far as we know, the estimated dose of the most severely exposed patient in the present study is the highest recorded among that chromosome analyses have been able to estimate in humans. (author)

  3. Using optically stimulated electrons from quartz for the estimation of natural doses

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Murray, A.S.; Denby, Phil M.

    2009-01-01

    A flow-through Geiger-Müller pancake electron detector attachment has been fitted to a standard Risø TL/OSL reader enabling optically stimulated electrons (OSE) to be measured simultaneously with optically stimulated luminescence (OSL). Using this detector, OSE and OSL measurements from natural......, a dose recovery test shows that OSE can successfully recover a laboratory dose of 300 Gy given before any laboratory thermal treatment, for preheating temperatures between 160 and 260 °C. Furthermore, for the first time natural OSE decay curves are detected and these signals are used to estimate a burial...... dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry....

  4. Estimation of 1945 to 1957 food consumption. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.M.; Bates, D.J.; Marsh, T.L.

    1993-07-01

    This report details the methods used and the results of the study on the estimated historic levels of food consumption by individuals in the Hanford Environmental Dose Reconstruction (HEDR) study area from 1945--1957. This period includes the time of highest releases from Hanford and is the period for which data are being collected in the Hanford Thyroid Disease Study. These estimates provide the food-consumption inputs for the HEDR database of individual diets. This database will be an input file in the Hanford Environmental Dose Reconstruction Integrated Code (HEDRIC) computer model that will be used to calculate the radiation dose. The report focuses on fresh milk, eggs, lettuce, and spinach. These foods were chosen because they have been found to be significant contributors to radiation dose based on the Technical Steering Panel dose decision level.

  5. Cardiac dose estimates from Danish and Swedish breast cancer radiotherapy during 1977-2001

    International Nuclear Information System (INIS)

    Taylor, Carolyn W.; Bronnum, Dorthe; Darby, Sarah C.; Gagliardi, Giovanna; Hall, Per; Jensen, Maj-Britt; McGale, Paul; Nisbet, Andrew; Ewertz, Marianne

    2011-01-01

    Background and purpose: To estimate target and cardiac doses from breast cancer radiotherapy in Denmark and in the Stockholm and Umea areas of Sweden during 1977-2001. Methods: Representative samples of irradiated women were identified from the databases of the Danish Breast Cancer Cooperative Group and the Swedish Nationwide Cancer Registry. Virtual simulation, computed tomography planning and manual planning were used to reconstruct radiotherapy regimens on a typical woman. Estimates of target dose and various measures of cardiac dose were derived from individual radiotherapy charts. Results: Doses were estimated in 681 Danish and 130 Swedish women. Mean heart dose for individual women varied from 1.6 to 14.9 Gray in Denmark and from 1.2 to 22.1 Gray in Sweden. In Denmark, mean target doses averaged across women increased from 40.6 to 53.8 Gray during 1977-2001 but, despite this, mean heart dose averaged across women remained around 6 Gy for left-sided and 2-3 Gray for right-sided radiotherapy. In Sweden mean target dose averaged across women increased from 38.7 to 46.6 Gray during 1977-2001, while mean heart dose averaged across women decreased from 12.0 to 7.3 Gray for left-sided and from 3.6 to 3.2 Gray for right-sided radiotherapy. Temporal trends for mean biologically effective dose [BED] to the heart, mean dose to the left anterior descending coronary artery, the right coronary artery and the circumflex coronary artery were broadly similar. Conclusions: Cardiac doses in Denmark were low relative to those in Sweden. In both countries, target dose increased during 1977-2001. Despite this, cardiac doses remained constant in Denmark and decreased in Sweden.

  6. Comparing different methods for estimating radiation dose to the conceptus

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X.; Dedulle, A. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Walgraeve, M.S.; Woussen, S.; Zhang, G. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Bosmans, H. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); GE Healthcare, Buc (France)

    2017-02-15

    To compare different methods available in the literature for estimating radiation dose to the conceptus (D{sub conceptus}) against a patient-specific Monte Carlo (MC) simulation and a commercial software package (CSP). Eight voxel models from abdominopelvic CT exams of pregnant patients were generated. D{sub conceptus} was calculated with an MC framework including patient-specific longitudinal tube current modulation (TCM). For the same patients, dose to the uterus, D{sub uterus}, was calculated as an alternative for D{sub conceptus}, with a CSP that uses a standard-size, non-pregnant phantom and a generic TCM curve. The percentage error between D{sub uterus} and D{sub conceptus} was studied. Dose to the conceptus and percent error with respect to D{sub conceptus} was also estimated for three methods in the literature. The percentage error ranged from -15.9% to 40.0% when comparing MC to CSP. When comparing the TCM profiles with the generic TCM profile from the CSP, differences were observed due to patient habitus and conceptus position. For the other methods, the percentage error ranged from -30.1% to 13.5% but applicability was limited. Estimating an accurate D{sub conceptus} requires a patient-specific approach that the CSP investigated cannot provide. Available methods in the literature can provide a better estimation if applicable to patient-specific cases. (orig.)

  7. Estimating average glandular dose by measuring glandular rate in mammograms

    International Nuclear Information System (INIS)

    Goto, Sachiko; Azuma, Yoshiharu; Sumimoto, Tetsuhiro; Eiho, Shigeru

    2003-01-01

    The glandular rate of the breast was objectively measured in order to calculate individual patient exposure dose (average glandular dose) in mammography. By employing image processing techniques and breast-equivalent phantoms with various glandular rate values, a conversion curve for pixel value to glandular rate can be determined by a neural network. Accordingly, the pixel values in clinical mammograms can be converted to the glandular rate value for each pixel. The individual average glandular dose can therefore be calculated using the individual glandular rates on the basis of the dosimetry method employed for quality control in mammography. In the present study, a data set of 100 craniocaudal mammograms from 50 patients was used to evaluate our method. The average glandular rate and average glandular dose of the data set were 41.2% and 1.79 mGy, respectively. The error in calculating the individual glandular rate can be estimated to be less than ±3%. When the calculation error of the glandular rate is taken into consideration, the error in the individual average glandular dose can be estimated to be 13% or less. We feel that our method for determining the glandular rate from mammograms is useful for minimizing subjectivity in the evaluation of patient breast composition. (author)

  8. ESR dating of elephant teeth and radiation dose rate estimation in soil

    International Nuclear Information System (INIS)

    Taisoo Chong; Ohta, Hiroyuki; Nakashima, Yoshiyuki; Iida, Takao; Saisho, Hideo

    1989-01-01

    Chemical analysis of 238 U, 232 Th and 40 K in the dentine as well as enamel of elephant tooth fossil has been carried out in order to estimate the internal absorbed dose rate of the specimens, which was estimated to be (39±4) mrad/y on the assumption of early uptake model of radionuclides. The external radiation dose rate in the soil including the contribution from cosmic rays was also estimated to be (175±18) mrad/y with the help of γ-ray spectroscopic techniques of the soil samples in which the specimens were buried. The 60 Co γ-ray equivalent accumulated dose of (2±0.2) x 10 4 rad for the tooth enamel gave ''ESR age'' of (9±2) x 10 4 y, which falls in the geologically estimated range between 3 x 10 4 and 30 x 10 4 y before the present. (author)

  9. Ladtap XL Version 2017: A Spreadsheet For Estimating Dose Resulting From Aqueous Releases

    Energy Technology Data Exchange (ETDEWEB)

    Minter, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jannik, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-15

    LADTAP XL© is an EXCEL© spreadsheet used to estimate dose to offsite individuals and populations resulting from routine and accidental releases of radioactive materials to the Savannah River. LADTAP XL© contains two worksheets: LADTAP and IRRIDOSE. The LADTAP worksheet estimates dose for environmental pathways including external exposure resulting from recreational activities on the Savannah River and internal exposure resulting from ingestion of water, fish, and invertebrates originating from the Savannah River. IRRIDOSE estimates offsite dose to individuals and populations from irrigation of foodstuffs with contaminated water from the Savannah River. In 2004, a complete description of the LADTAP XL© code and an associated user’s manual was documented in LADTAP XL©: A Spreadsheet for Estimating Dose Resulting from Aqueous Release (WSRC-TR-2004-00059) and revised input parameters, dose coefficients, and radionuclide decay constants were incorporated into LADTAP XL© Version 2013 (SRNL-STI-2011-00238). LADTAP XL© Version 2017 is a slight modification to Version 2013 with minor changes made for more user-friendly parameter inputs and organization, updates in the time conversion factors used within the dose calculations, and fixed an issue with the expected time build-up parameter referenced within the population shoreline dose calculations. This manual has been produced to update the code description, verification of the models, and provide an updated user’s manual. LADTAP XL© Version 2017 has been verified by Minter (2017) and is ready for use at the Savannah River Site (SRS).

  10. Dose estimates in a loss of lead shielding truck accident.

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, Matthew L.; Osborn, Douglas M.; Weiner, Ruth F.; Heames, Terence John (Alion Science & Technology Albuquerque, NM)

    2009-08-01

    The radiological transportation risk & consequence program, RADTRAN, has recently added an updated loss of lead shielding (LOS) model to it most recent version, RADTRAN 6.0. The LOS model was used to determine dose estimates to first-responders during a spent nuclear fuel transportation accident. Results varied according to the following: type of accident scenario, percent of lead slump, distance to shipment, and time spent in the area. This document presents a method of creating dose estimates for first-responders using RADTRAN with potential accident scenarios. This may be of particular interest in the event of high speed accidents or fires involving cask punctures.

  11. Estimation of effective dose for children in interventional cardiology

    Directory of Open Access Journals (Sweden)

    S. S. Sarycheva

    2017-01-01

    Full Text Available This study is devoted to the estimation of effective dose for children undergoing interventional cardiology examinations. The conversion coefficients (CC from directly measured dose area product (DAP value to effective dose (ED were calculated within the approved effective dose assessment methodology (Guidelines 2.6.1. 2944-11. The CC, Ed K , [mSv / (Gy • cm2] for newborn infants and children of 1, 5, 10 and 15 years old (main(range were calculated as 2.5 (1.8-3.2; 1.1 (0.8-1.3; 0.6 (0.4-0.7; 0.4 (0.3-0.5; and 0,22 (0,18-0,30 respectively. A special Finnish computer program PCXMC 2.0 was used for calculating the dose CC. The series of calculations were made for different values of the physical and geometrical parameters based on their real-existing range of values. The value of CC from DAP to ED were calculated for all pediatric age groups. This work included 153 pediatric interventional studies carried out in two hospitals of the city of St. Petersburg for the period of one year from the summer of 2015. The dose CC dependency from the patient’s age and parameters of the examinations were under the study. The dependence from the beam quality (filtration and tube voltage and age of the patient were found. The younger is the patient, stronger is the filtration and higher is the voltage, the higher is the CC value. The CC in the younger (newborn and older (15 years age groups are different by the factor of 10. It was shown that the changes of the geometric parameters (in the scope of their real existing range have small effect on the value of the effective dose, not exceed 30-50% allowable for radiation protection purpose. The real values of effective doses of children undergoing cardiac interventions were estimated. In severe cases, the values of ED can reach several tens of mSv.

  12. Validation of radiosterilization dose of human skin dressings for burnt treatment: preliminary study

    International Nuclear Information System (INIS)

    Castro, E.

    2008-01-01

    Full text: Due to the need for better materials to treat burnt patients, the Peruvian Institute of Nuclear Energy (IPEN) and the Rosa Guerzoni Chambergo Tissue Bank are collaborating for developing human skin dressings. Skin was procured from living donors, who surgically were performed a dermolipectomy. Exclusion criteria, stated by the Peruvian Organization for Transplant and Donation were observed. Glycerolized human skin dressings were processed at the tissue bank and sent to IPEN, where the gamma irradiation sterilizing dose was determined. The purpose of this work is to validate the radiation sterilization dose delivered to human skin dressings using the IAEA Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control. A batch of human skin dressings was tested. Average values of bioburden present in ten samples was 30 UFC/item, obtaining a sub-sterilization dose of 4 kGy. Irradiations were performed in the GammacellExcel 220. Sterility tests performed fulfilled the requirements established by the Code, achieving a validated dose value of 19.7 kGy. This preliminary study, that should be repeated in two other batches of processed human skin, allows to diminish 25 kGy the sterilizing dose to the stated above dose value, in a frame of a quality assurance system that also comprises the processes held at tissue banks previous irradiation. It also permit the availability of these materials in Peruvian hospitals. (Author)

  13. Coincidence in the dose estimation in a OEP by different methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; Arceo M, C.; Brena V, M.

    2007-01-01

    The case of an apparent overexposure to radiation according to that indicated for the thermoluminescent dosemeter 81.59 mSv (TLD) of a occupationally exposed hard-working (POE), for that was practiced the study of biological dosimetry. The estimated dose was 0.12 Gy with which was proven the marked dose registration by the TLD dosemeter. It was concluded that both doses are the same ones. (Author)

  14. Estimates of radiation doses and cancer risk from food intake in Korea

    International Nuclear Information System (INIS)

    Moon, Eun Kyeong; Lee, Won Jin; Ha, Wi Ho; Seo, Song Won; Jin, Young Woo; Jeong, Kyu Hwan; Yoon, Hae Jung; Kim, Hyoung Soo; Hwang, Myung Sil; Choi, Hoon

    2016-01-01

    After the Fukushima Daiichi nuclear power plant accident, a widespread public concern for radiation exposure through the contamination of domestic or imported food has continued worldwide. Because the internal exposure from contaminated food is an important consideration for human health effect, some studies for estimating radiation doses and cancer risk from the Fukushima nuclear accident have been conducted in several countries (1). The aims of the study is to estimate internal radiation dose and lifetime risks of cancer from food ingestion in Korean population. Our findings suggest no discernible increase n radiation doses or excess fatal cancer risk from food ingestion at this stage in Korea, and provide scientific evidence of the risk communication with general public associated with low-dose radiation exposure.

  15. Estimates of radiation doses and cancer risk from food intake in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Eun Kyeong; Lee, Won Jin [Korea University, Seoul (Korea, Republic of); Ha, Wi Ho; Seo, Song Won; Jin, Young Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Jeong, Kyu Hwan [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Yoon, Hae Jung; Kim, Hyoung Soo; Hwang, Myung Sil [Ministry of Food and Drug Safety, Cheongju (Korea, Republic of); Choi, Hoon [Wonkwang University, Iksan (Korea, Republic of)

    2016-04-15

    After the Fukushima Daiichi nuclear power plant accident, a widespread public concern for radiation exposure through the contamination of domestic or imported food has continued worldwide. Because the internal exposure from contaminated food is an important consideration for human health effect, some studies for estimating radiation doses and cancer risk from the Fukushima nuclear accident have been conducted in several countries (1). The aims of the study is to estimate internal radiation dose and lifetime risks of cancer from food ingestion in Korean population. Our findings suggest no discernible increase n radiation doses or excess fatal cancer risk from food ingestion at this stage in Korea, and provide scientific evidence of the risk communication with general public associated with low-dose radiation exposure.

  16. Estimation of the absorbed dose in radiation-processed food. Pt.2

    International Nuclear Information System (INIS)

    Desrosiers, M.F.

    1991-01-01

    The use of electron paramagnetic resonance spectroscopy to accurately evaluate the absorbed dose to radiation-processed bones (and thus meats) is examined. Additive re-irradiation of the bone produces a reproducible response function which can be used to evaluate the initial dose by back-extrapolation. It was found that an exponential fit (vs linear or polynomial) to the data provides improved accuracy of the estimated dose. These data as well as the protocol for the additive dose method are presented. (author)

  17. TU-F-CAMPUS-I-03: Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan

    International Nuclear Information System (INIS)

    Tsai, H; Hu, Y; Hwang, Y

    2015-01-01

    Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effective diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan

  18. Doses in pediatric patients undergoing chest and abdomen CT examinations. Preliminary results

    International Nuclear Information System (INIS)

    Jornada, Tiago S.; Silva, Teogenes A. da

    2011-01-01

    Computed tomography (CT) is a non-invasive method of image production that imparts significant doses to a patient, it is expected that pediatric CT examinations will increase the risk of induced cancer in children. In this study the effective doses in a five year-old child submitted to chest or abdomen CT scans were assessed for comparison purposes. The CTEXPO computed program was used with data from routine protocols of a 0 to 13 year-old children in two public hospitals in Belo Horizonte. Hospital A used a Siemens Dual-Slice unit with 80 kV, 41 mA and pitch 2 for chest or abdomen; hospital B used a Multislice GE unit with 120 kV, 45 mA and pitch 1 for chest and 120 kV, 55 mA. and pitch 1 for abdomen. Results of effective doses in a five year-old child were 1.7 and 1.0 mSv in hospital A and 9.1 and 7.2 mSv in hospital B, for chest and abdomen, respectively. Results were compared to the reference effective doses of 7.2 and 5.0 mSv for chest and abdomen respectively that were derived from the air kerma length product values given in ICRP publication 87. Results of hospital A showed that low dose exposures also can be achieved in CT scans of children. Results showed that even a hospital with a modern facility (hospital B) can provided doses higher than reference values if protocols are not adjusted for children. Preliminary results suggested that there is a room for optimizing children exposure submitted to CT scans. (author)

  19. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    International Nuclear Information System (INIS)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo; Koo, Bon Cheol; Chang, Byung Uck

    2016-01-01

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries

  20. Development of internal dose assessment procedure for workers in industries using raw materials containing naturally occurring radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Cheol Kyu; KIm, Yong Geon; Ji, Seung Woo; Kim, Kwang Pyo [College of Engineering, Kyung Hee University, Yongin (Korea, Republic of); Koo, Bon Cheol; Chang, Byung Uck [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-09-15

    It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are 10 Bq·g-1 for 40K and 1 Bq·g-1 for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups (<0.1 mSv, 0.1-0.3 mSv, and >0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels (<0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and >1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

  1. SU-F-P-44: A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures

    International Nuclear Information System (INIS)

    Weir, V; Zhang, J

    2016-01-01

    Purpose: There is an increasing demand for medical physicist to calculate peak skin dose (PSD) for interventional fluoroscopy procedures. The dose information (Dose-Area-Product and Air Kerma) displayed in the console cannot directly be used for this purpose. Our clinical experience shows that the use of the existing methods may overestimate or underestimate PSD. This study attempts to develop a direct estimate of PSD from the displayed dose metrics. Methods: An anthropomorphic torso phantom was used for dose measurements for a common fluoroscopic procedure. Entrance skin doses were measured with a Piranha solid state point detector placed on the table surface below the torso phantom. An initial “reference dose rate” (RE) measurement was conducted by comparing the displayed dose rate (mGy/min) to the dose rate measured. The distance from table top to focal spot was taken as the reference distance (RD at the RE. Table height was then adjusted. The displayed air kerma and DAP were recorded and sent to three physicists to estimate PSD. An inverse square correction was applied to correct displayed air kerma at various table heights. The PSD estimated by physicists and the PSD by the proposed method were then compared with the measurements. The estimated DAPs were compared to displayed DAP readings (mGycm2). Results: The difference between estimated PSD by the proposed method and direct measurements was less than 5%. For the same set of data, the estimated PSD by each of three physicists is different from measurements by ±52%. The DAP calculated by the proposed method and displayed DAP readings in the console is less than 20% at various table heights. Conclusion: PSD may be simply estimated from displayed air kerma or DAP if the distance between table top and tube focal spot or if x-ray beam area on table top is available.

  2. SU-F-P-44: A Direct Estimate of Peak Skin Dose for Interventional Fluoroscopy Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Scott and White Healthcare System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2016-06-15

    Purpose: There is an increasing demand for medical physicist to calculate peak skin dose (PSD) for interventional fluoroscopy procedures. The dose information (Dose-Area-Product and Air Kerma) displayed in the console cannot directly be used for this purpose. Our clinical experience shows that the use of the existing methods may overestimate or underestimate PSD. This study attempts to develop a direct estimate of PSD from the displayed dose metrics. Methods: An anthropomorphic torso phantom was used for dose measurements for a common fluoroscopic procedure. Entrance skin doses were measured with a Piranha solid state point detector placed on the table surface below the torso phantom. An initial “reference dose rate” (RE) measurement was conducted by comparing the displayed dose rate (mGy/min) to the dose rate measured. The distance from table top to focal spot was taken as the reference distance (RD at the RE. Table height was then adjusted. The displayed air kerma and DAP were recorded and sent to three physicists to estimate PSD. An inverse square correction was applied to correct displayed air kerma at various table heights. The PSD estimated by physicists and the PSD by the proposed method were then compared with the measurements. The estimated DAPs were compared to displayed DAP readings (mGycm2). Results: The difference between estimated PSD by the proposed method and direct measurements was less than 5%. For the same set of data, the estimated PSD by each of three physicists is different from measurements by ±52%. The DAP calculated by the proposed method and displayed DAP readings in the console is less than 20% at various table heights. Conclusion: PSD may be simply estimated from displayed air kerma or DAP if the distance between table top and tube focal spot or if x-ray beam area on table top is available.

  3. Dose estimation from food intake due to the Fukushima Daiichi nuclear power plant accident

    International Nuclear Information System (INIS)

    Yamaguchi, Ichiro; Terada, Hiroshi; Kunugita, Naoki; Takahashi, Kunihiko

    2013-01-01

    Since the Fukushima Daiichi nuclear power plant accident, concerns have arisen about the radiation safety of food raised at home and abroad. Therefore, many measures have been taken to address this. To evaluate the effectiveness of these measures, dose estimation due to food consumption has been attempted by various methods. In this paper, we show the results of dose estimation based on the monitoring data of radioactive materials in food published by the Ministry of Health, Labour and Welfare. The Radioactive Material Response Working Group in the Food Sanitation Subcommittee of the Pharmaceutical Affairs and Food Sanitation Council reported such dose estimation results on October 31, 2011 using monitoring data from immediately after the accident through September, 2011. Our results presented in this paper were the effective dose and thyroid equivalent dose integrated up to December 2012 from immediately after the accident. The estimated results of committed effective dose by age group derived from the radioiodine and radiocesium in food after the Fukushima Daiichi nuclear power plant accident showed the highest median value (0.19 mSv) in children 13-18 years of age. The highest 95% tile value, 0.33 mSv, was shown in the 1-6 years age range. These dose estimations from food can be useful for evaluation of radiation risk for individuals or populations and for radiation protection measures. It would also be helpful for the study of risk management of food in the future. (author)

  4. A theoretical approach to the problem of dose-volume constraint estimation and their impact on the dose-volume histogram selection

    International Nuclear Information System (INIS)

    Schinkel, Colleen; Stavrev, Pavel; Stavreva, Nadia; Fallone, B. Gino

    2006-01-01

    This paper outlines a theoretical approach to the problem of estimating and choosing dose-volume constraints. Following this approach, a method of choosing dose-volume constraints based on biological criteria is proposed. This method is called ''reverse normal tissue complication probability (NTCP) mapping into dose-volume space'' and may be used as a general guidance to the problem of dose-volume constraint estimation. Dose-volume histograms (DVHs) are randomly simulated, and those resulting in clinically acceptable levels of complication, such as NTCP of 5±0.5%, are selected and averaged producing a mean DVH that is proven to result in the same level of NTCP. The points from the averaged DVH are proposed to serve as physical dose-volume constraints. The population-based critical volume and Lyman NTCP models with parameter sets taken from literature sources were used for the NTCP estimation. The impact of the prescribed value of the maximum dose to the organ, D max , on the averaged DVH and the dose-volume constraint points is investigated. Constraint points for 16 organs are calculated. The impact of the number of constraints to be fulfilled based on the likelihood that a DVH satisfying them will result in an acceptable NTCP is also investigated. It is theoretically proven that the radiation treatment optimization based on physical objective functions can sufficiently well restrict the dose to the organs at risk, resulting in sufficiently low NTCP values through the employment of several appropriate dose-volume constraints. At the same time, the pure physical approach to optimization is self-restrictive due to the preassignment of acceptable NTCP levels thus excluding possible better solutions to the problem

  5. Dose estimation in CT exams of the abdomen based on values of DLP

    International Nuclear Information System (INIS)

    Kikuti, C.F.; Medeiros, R.B.; Salvadori, P.S.; Costa, D.M.C; D'lppolito, G.

    2013-01-01

    One of the challenges of multidetector computerized tomography is to minimize the risk of ionizing radiation using optimized protocols since higher doses are necessary to obtain high image quality. It was also noted that, due to the geometry in image acquisition using MDCT becomes necessary to estimate dose values consistent with the hypothesis clinically and with the specificities of the tomographic equipment. The aim of this study was to estimate the doses in abdomen exams from the data recorded on the MDCT console and dimensions obtained from DICOM images of patients undergoing different clinical protocols. Were collected, from the image DICOM of 101 exams, values of the dose length product (DLP) provided by Philips Health Care - Brilliance 64 equipment console, in order to relate them with the dose values obtained by means of thermoluminescent dosimeters ( TLD ) of CasSo 4 :Mn placed on the surface of a cylindrical simulator abdomen acrylic manufactured under the technical - operational conditions for a typical abdomen exam. From the data obtained, it was possible to find a factor of 1.16 ( 5 % ) indicating that the DLP values Brilliance 64 console underestimate the doses and this should be used with correction factor to estimate the total dose of the patient. (author)

  6. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated [it

  7. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    Science.gov (United States)

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k

  8. Estimation Of Effective Dose In Ingestion Of Food Crops For 137Cs

    International Nuclear Information System (INIS)

    Angeleska, A.; Dimitrieska-Stojkovic, E.; Uzunov, R.; Hajrulai-Musliu, Z.; Stojanovska-Dimzoska, B.; Jankuloski, D.; Crceva-Nikolovska, R.

    2015-01-01

    The interaction of the ionizing radiation with the human body leads to various biological effects which afterwards can be manifested as clinical symptoms. The nature and the seriousness of the symptoms depend on the absorbed dose, as well as the dose rate, and many diseases which were supposed to be effectively managed if information for the radiation level of an environment was available. The knowledge of the concentration of radioactivity of our environment is of essential relevance in the assessment of the dose that is accumulated in the population, as well as for the formation of the basis for estimation of the level of radioactive contamination or contamination in the environment in future. Taking into consideration the relevance of the distribution and the transfer of radionuclides from the soil to the crops, this work was aimed to estimate the effective dose in ingestion of separate crops for 137Cs. The effective dose was determined by means of already known transfer factors from the soil to the plants and measured concentrations of activities of soil from specific locations in the surrounding of the city of Skopje. The agricultural crops used for analysis are the most commonly applied crops (vegetables, legumes, root crops) in Republic of Macedonia. The radiometric analysis of these samples was conducted by applying a spectrometer for gamma-rays with Germanium with high purity (HPGe). The estimated effective dose would apply for adults who ingested the mentioned crops which were produced at the mentioned locations, that is, in the region of Skopje. These data can be the basis for estimation of risk for radioactive contamination of the population, received by ingestion of produced food. (author).

  9. Preliminary Cost Estimates for Nuclear Hydrogen Production: HTSE System

    International Nuclear Information System (INIS)

    Yang, K. J.; Lee, K. Y.; Lee, T. H.

    2008-01-01

    KAERI is now focusing on the research and development of the key technologies required for the design and realization of a nuclear hydrogen production system. As a preliminary study of cost estimates for nuclear hydrogen systems, the hydrogen production costs of the nuclear energy sources benchmarking GTMHR and PBMR are estimated in the necessary input data on a Korean specific basis. G4-ECONS was appropriately modified to calculate the cost for hydrogen production of HTSE (High Temperature Steam Electrolysis) process with VHTR (Very High Temperature nuclear Reactor) as a thermal energy source. The estimated costs presented in this paper show that hydrogen production by the VHTR could be competitive with current techniques of hydrogen production from fossil fuels if CO 2 capture and sequestration is required. Nuclear production of hydrogen would allow large-scale production of hydrogen at economic prices while avoiding the release of CO 2 . Nuclear production of hydrogen could thus become the enabling technology for the hydrogen economy. The major factors that would affect the cost of hydrogen were also discussed

  10. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  11. Estimation dose in organs of hyperthyroidism patients treated with I-131

    International Nuclear Information System (INIS)

    Farias de Lima, F.; Khoury, H.C.; Bertelli Neto, L.; Hazin, C.

    1997-01-01

    Full text: The absorbed dose in organs of hyperthyroidism patients, which received 370 MBq and 555 MBq of I-131 were estimated, using the MIRDOSE computational program and data of the ICRP-53 publication. The calculus were done considering an equal uptake to 45% and an effective half life of 5 days, these values are closed to the average values found in 17 studied patients. The thyroidal masses were previously determined by the physicians and varied between 40 g and 80 g The results showed that the dose in the thyroid, for an activity of 370 MBq, varied between 99 Gy and 49,5 Gy for the masses of 40 g and 80 g respectively. In the case of the administration of 555 MBq the patients had thyroidal masses between 60 g and 80 g and the doses varied between 99 Gy and 74,2 Gy, respectively. These values showed that the absorbed doses in thyroid are within limits expected for the hyperthyroidism therapy, which are of 506 Gy to 100 Gy. The 100 Gy dose would be exceeded, if the patients with thyroidal mass of 40 g had received a therapeutic dose of 555 MBq. The estimated media doses in others organs were relatively low, with inferior values of 0,1 Gy in kidneys, bone marrow and ovaries and of 0,19 Gy in stomach

  12. A preliminary assessment of selected atmospheric dispersion, food-chain transport, and dose-to-man computer codes for use by the DOE Office of Civilian Radioactive Waste Management

    International Nuclear Information System (INIS)

    Riggle, K.J.; Roddy, J.W.

    1989-02-01

    This work is part of the ongoing Systems Modeling Program at Oak Ridge National Laboratory, which is assisting the DOE Office of Civilian Radioactive Waste Management in selecting appropriate computer codes for the process of licensing a high-level radioactive waste repository or a monitored retrievable storage facility. A preliminary study of codes for predicting dose to man following airborne releases of radionuclides is described. These codes use models for estimating atmospheric dispersion of activity and deposition onto the ground surface, exposures via external irradiation, inhalation of airborne activity, and ingestion following transport through terrestrial food chains, and the dose per unit exposure for each exposure mode. A set of criteria is given for use in choosing codes for further examination. From a list of over 150 computer codes, five were selected for review

  13. Patient absorbed radiation doses estimation related to irradiation anatomy; Estimativa de dose absorvida pelo paciente relacionada a anatomia irradiada

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Flavio Augusto Penna; Soares, Amanda Anastacio; Kahl, Gabrielly Gomes, E-mail: prof.flavio@gmail.com, E-mail: amanda-a-soares@hotmail.com, E-mail: gabriellygkahl@gmail.com [Instituto Federal de Eduacao, Ciencia e Tecnologia de Santa Catarina (IFSC), Florianopolis, SC (Brazil)

    2014-07-01

    Developed a direct equation to estimate the absorbed dose to the patient in x-ray examinations, using electric, geometric parameters and filtering combined with data from irradiated anatomy. To determine the absorbed dose for each examination, the entrance skin dose (ESD) is adjusted to the thickness of the patient's specific anatomy. ESD is calculated from the estimated KERMA greatness in the air. Beer-Lambert equations derived from power data mass absorption coefficients obtained from the NIST / USA, were developed for each tissue: bone, muscle, fat and skin. Skin thickness was set at 2 mm and the bone was estimated in the central ray of the site, in the anteroposterior view. Because they are similar in density and attenuation coefficients, muscle and fat are treated as a single tissue. For evaluation of the full equations, we chose three different anatomies: chest, hand and thigh. Although complex in its shape, the equations simplify direct determination of absorbed dose from the characteristics of the equipment and patient. The input data is inserted at a single time and total absorbed dose (mGy) is calculated instantly. The average error, when compared with available data, is less than 5% in any combination of device data and exams. In calculating the dose for an exam and patient, the operator can choose the variables that will deposit less radiation to the patient through the prior analysis of each combination of variables, using the ALARA principle in routine diagnostic radiology sector.

  14. Impact of dose-distribution uncertainties on rectal ntcp modeling I: Uncertainty estimates

    International Nuclear Information System (INIS)

    Fenwick, John D.; Nahum, Alan E.

    2001-01-01

    A trial of nonescalated conformal versus conventional radiotherapy treatment of prostate cancer has been carried out at the Royal Marsden NHS Trust (RMH) and Institute of Cancer Research (ICR), demonstrating a significant reduction in the rate of rectal bleeding reported for patients treated using the conformal technique. The relationship between planned rectal dose-distributions and incidences of bleeding has been analyzed, showing that the rate of bleeding falls significantly as the extent of the rectal wall receiving a planned dose-level of more than 57 Gy is reduced. Dose-distributions delivered to the rectal wall over the course of radiotherapy treatment inevitably differ from planned distributions, due to sources of uncertainty such as patient setup error, rectal wall movement and variation in the absolute rectal wall surface area. In this paper estimates of the differences between planned and treated rectal dose-distribution parameters are obtained for the RMH/ICR nonescalated conformal technique, working from a distribution of setup errors observed during the RMH/ICR trial, movement data supplied by Lebesque and colleagues derived from repeat CT scans, and estimates of rectal circumference variations extracted from the literature. Setup errors and wall movement are found to cause only limited systematic differences between mean treated and planned rectal dose-distribution parameter values, but introduce considerable uncertainties into the treated values of some dose-distribution parameters: setup errors lead to 22% and 9% relative uncertainties in the highly dosed fraction of the rectal wall and the wall average dose, respectively, with wall movement leading to 21% and 9% relative uncertainties. Estimates obtained from the literature of the uncertainty in the absolute surface area of the distensible rectal wall are of the order of 13%-18%. In a subsequent paper the impact of these uncertainties on analyses of the relationship between incidences of bleeding

  15. NIRS external dose estimation system for Fukushima residents after the Fukushima Dai-ichi NPP accident

    Science.gov (United States)

    Akahane, Keiichi; Yonai, Shunsuke; Fukuda, Shigekazu; Miyahara, Nobuyuki; Yasuda, Hiroshi; Iwaoka, Kazuki; Matsumoto, Masaki; Fukumura, Akifumi; Akashi, Makoto

    2013-04-01

    The great east Japan earthquake and subsequent tsunamis caused Fukushima Dai-ichi Nuclear Power Plant (NPP) accident. National Institute of Radiological Sciences (NIRS) developed the external dose estimation system for Fukushima residents. The system is being used in the Fukushima health management survey. The doses can be obtained by superimposing the behavior data of the residents on the dose rate maps. For grasping the doses, 18 evacuation patterns of the residents were assumed by considering the actual evacuation information before using the survey data. The doses of the residents from the deliberate evacuation area were relatively higher than those from the area within 20 km radius. The estimated doses varied from around 1 to 6 mSv for the residents evacuated from the representative places in the deliberate evacuation area. The maximum dose in 18 evacuation patterns was estimated to be 19 mSv.

  16. I-125 seed dose estimates in heterogeneous phantom

    International Nuclear Information System (INIS)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio

    2015-01-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  17. I-125 seed dose estimates in heterogeneous phantom

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio, E-mail: isabela.slbranco@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  18. Estimation of population doses from stomach mass screening, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Kato, Y; Maruyama, T [National Inst. of Radiological Sciences, Chiba (Japan); Kamata, R; Urahashi, S

    1977-06-01

    The population dose from mass photofluorography of stomach have been estimated on the basis of nation wide radiological survey. The number of photofluorographic examinations was 2.38 million for male and 1.74 million for female, with a total of 4.12 million. The gonad doses were determined with an ionization chamber, using a tissue equivalent phantom. The gonad dose for male was 10.4 mrad per examination and for female was 150 mrad per examination. The active bone marrow doses at 32 points of bone marrow in the whole body were measured with thermoluminescent dosimeter. The mean marrow dose per photofluorographic examination was 450 mrad for male and 390 mrad for female. The child expectancy factor and the leukemia significant factor were calculated based on the Vital Statistics 1975. The genetically significant dose (GSD) and per caput mean marrow dose (CMD) were calculated by the formulae presented from the United Nations Scientific Comittee of Effects of Atomic Radiation (UNSCEAR). The resultant GSD was 0.15 mrad per person per year. The CMD was 16.5 mrad per person per year. The leukemia significant dose (LSD) was determined by adopting a weight factor, that is leukemia significant factor. The resultant LSD was 14.5 mrad per person per year. These population doses were compared with those from diagnostic medical x-ray examinations in 1974.

  19. Improvements on a patient-specific dose estimation system in nuclear medicine examination

    International Nuclear Information System (INIS)

    Chuang, K. S.; Lu, J. C.; Lin, H. H.; Dong, S. L.; Yang, H. J.; Shih, C. T.; Lin, C. H.; Yao, W. J.; Ni, Y. C.; Jan, M. L.; Chang, S. J.

    2014-01-01

    The purpose of this paper is to develop a patient-specific dose estimation system in nuclear medicine examination. A dose deposition routine to store the deposited energy of the photons during their flights was embedded in the widely used SimSET Monte Carlo code and a user-friendly interface for reading PET and CT images was developed. Dose calculated on ORNL phantom was used to validate the accuracy of this system. The ratios of S value for 99m Tc, 18 F and 131 I computed by this system to those obtained with OLINDA for various organs were ranged from 0.93 to 1.18, which were comparable to that obtained from MCNPX2.6 code (0.88-1.22). Our system developed provides opportunity for tumor dose estimation which cannot be known from the MIRD. The radiation dose can provide useful information in the amount of radioisotopes to be administered in radioimmunotherapy. (authors)

  20. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  1. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  2. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  3. A Cs-137 afterloading device. Preliminary results of cell kinetic effects of low dose-rate irradiation in an experimental tumour

    International Nuclear Information System (INIS)

    Rutgers, D.H.

    1988-01-01

    A Cs-137 afterloading technique is described which can be used in experimental tumours. Preliminary results, obtained with the human cervical carcinoma ME-180 xenografted to nude athymic mice, demonstrated that 20 Gy of low dose-rate irradiation induced an important redistribution of cells over cell cycle. The proportion of cells in G2-phase increased from 14.4% to 44.2% at 140 hours after irradiation. This method allows an accurate calculation of the dose-rate distribution in the tumour. Investigations of the cell kinetic effects of low dose-rate irradiation, at different dose-rates and different total doses, are therefore facilitated by the technique. (orig.) [de

  4. Estimation of dose distribution in occupationally exposed individuals to FDG-18F

    International Nuclear Information System (INIS)

    Lacerda, Isabelle V. Batista de; Cabral, Manuela O. Monteiro; Vieira, Jose Wilson

    2014-01-01

    The use of unsealed radiation sources in nuclear medicine can lead to important incorporation of radionuclides, especially for occupationally exposed individuals (OEIs) during production and handling of radiopharmaceuticals. In this study, computer simulation was proposed as an alternative methodology for evaluation of the absorbed dose distribution and for the effective dose value in OEIs. For this purpose, the Exposure Computational Model (ECM) which is named as FSUP (Female Adult Mesh - supine) were used. This ECM is composed of: voxel phantom FASH (Female Adult MeSH) in the supine position, the MC code EGSnrc and an algorithm simulator of general internal source. This algorithm was modified to adapt to specific needs of the positron emission from FDG- 18 F. The obtained results are presented as absorbed dose/accumulated activity. To obtain the absorbed dose distribution it was necessary to use accumulative activity data from the in vivo bioassay. The absorbed dose distribution and the value of estimated effective dose in this study did not exceed the limits for occupational exposure. Therefore, the creation of a database with the distribution of accumulated activity is suggested in order to estimate the absorbed dose in radiosensitive organs and the effective dose for OEI in similar environment. (author)

  5. Fetal dose from radiotherapy photon beams: Physical basis, techniques to estimate radiation dose outside of the treatment field, biological effects and professional considerations

    International Nuclear Information System (INIS)

    Stovell, Marilyn; Blackwell, C. Robert

    1997-01-01

    Purpose/Objective: The presentation will review: 1. The physical basis of radiation dose outside of the treatment field. 2. Techniques to estimate and reduce fetal dose. 3. Clinical examples of fetal dose estimation and reduction. 4. Biological effects of fetal irradiation. 5. Professional considerations. Approximately 4000 women per year in the United States require radiotherapy during pregnancy. This report presents data and techniques that allow the medical physicist to estimate the radiation dose the fetus will receive and to reduce this dose with appropriate shielding. Out-of-beam data are presented for a variety of photon beams, including cobalt-60 gamma rays and x rays from 4 to 18 MV. Designs for simple and inexpensive to more complex and expensive types of shielding equipment are described. Clinical examples show that proper shielding can reduce the radiation dose to the fetus by 50%. In addition, a review of the biological aspects of irradiation enables estimates of the risks of lethality, growth retardation, mental retardation, malformation, sterility, cancer induction, and genetic defects to the fetus. A summary of professional considerations/recommendations is also provided as a guide for the radiation oncologist and medical physicist

  6. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose- effect curve)

    International Nuclear Information System (INIS)

    Al Achkar, W.

    2002-01-01

    In order to draw a dose-effect curve, blood from eight healthy people were studied. Samples were irradiated in tubes with 0.15-2.5 gray of gamma ray.Irradiated and control samples were incubated for cell cultures. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics+ rings and total numbers of breaks were drawn. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  7. Effects of the loss of correlation structure on Phase 1 dose estimates

    International Nuclear Information System (INIS)

    Simpson, J.C.

    1991-11-01

    In Phase I of the Hanford Environmental Dose Reconstruction Project, a step-by-step (modular) calculational structure was used. This structure was intended (1) to simplify the computational process, (2) to allow storage of intermediate calculations for later analyses, and (3) to guide the collection of data by presenting understandable structures for its use. The implementation of this modular structure resulted in the loss of correlation among inputs and outputs of the code, resulting in less accurate dose estimates than anticipated. The study documented in this report investigated two types of correlations in the Phase I model: temporal and pathway. Temporal correlations occur in the simulation when, in the calculation, data estimated for a previous time are used in a subsequent calculation. If the various portions of the calculation do not use the same realization of the earlier estimate, they are no longer correlated with respect to time. Similarly, spatial correlations occur in a simulation when, in the calculation, data estimated for a particular location are used in estimates for other locations. If the various calculations do not use the same value for the original location, they are no longer correlated with respect to location. The loss of the correlation structure in the Phase I code resulted in dose estimates that are biased. It is recommended that the air pathway dose model be restructured and the intermediate histograms eliminated. While the restructured code may still contain distinct modules, all input parameters to each module and all out put from each module should be retained in a database such that subsequent modules can access all the information necessary to retain the correlation structure

  8. Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, Felipe; Graeff, Carlos F.O.; Baffa, Oswaldo

    2002-01-01

    The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60 Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated. (author)

  9. Preliminary Estimates of Specific Discharge and Transport Velocities near Borehole NC-EWDP-24PB

    International Nuclear Information System (INIS)

    Freifeld, Barry; Doughty, Christine; Finsterle, Stefan

    2006-01-01

    This report summarizes fluid electrical conductivity (FEC) and thermal logging data collected in Borehole NC-EWDP-24PB, located approximately 15 km south of the proposed repository at Yucca Mountain. Preliminary analyses of a small fraction of the FEC and temperature data indicate that relatively large, localized fluid fluxes are likely to exist at this location. The implication that considerable flow is induced by small gradients, and that flow is highly localized, is significant for the estimation of groundwater transport velocities and radionuclide travel times. The sensitivity of the data to potential perturbations during testing (i.e., internal wellbore flow in the case of FEC data, and buoyancy effects in the case of thermal logging data) make it difficult to conclusively derive fluid fluxes and transport velocities without a detailed analysis of all data and processes involved. Such a comprehensive analysis has not yet been performed. However, the preliminary results suggest that the ambient component of the estimated flow rates is significant and on the order of liters per minute, yielding groundwater transport velocities in the range of kilometers per year. One particular zone in the Bullfrog tuff exhibits estimated velocities on the order of 10 km/yr. Given that the preliminary estimates of ambient flow rates and transport velocities are relatively high, and considering the potential impact of high rates and velocities on saturated-zone flow and transport behavior, we recommend that a comprehensive analysis of all the available data be performed. Moreover, additional data sets at other locations should be collected to examine whether the current data set is representative of the regional flow system near Yucca Mountain

  10. Estimation of four-dimensional dose distribution using electronic portal imaging device in radiation therapy

    International Nuclear Information System (INIS)

    Mizoguchi, Asumi; Arimura, Hidetaka; Shioyama, Yoshiyuki

    2013-01-01

    We are developing a method to evaluate four-dimensional radiation dose distribution in a patient body based upon the animated image of EPID (electronic portal imaging device) which is an image of beam-direction at the irradiation. In the first place, we have obtained the image of the dose which is emitted from patient body at therapy planning using therapy planning CT image and dose evaluation algorism. In the second place, we have estimated the emission dose image at the irradiation using EPID animated image which is obtained at the irradiation. In the third place, we have got an affine transformation matrix including respiratory movement in the body by performing linear registration on the emission dose image at therapy planning to get the one at the irradiation. In the fourth place, we have applied the affine transformation matrix on the therapy planning CT image and estimated the CT image 'at irradiation'. Finally we have evaluated four-dimensional dose distribution by calculating dose distribution in the CT image 'at irradiation' which has been estimated for each frame of the EPID animated-image. This scheme may be useful for evaluating therapy results and risk management. (author)

  11. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  12. Studies on the reference Korean and estimation of radiation exposure dose

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.J.; Kim, J.B.; Chung, G.H.; Kim, S.R.

    1982-01-01

    For the purpose of establishment of Reference Korean and estimation of internal and external exposure doses in the Reference Korean, we have surveyed reference values for Koreans such as physical standards including height, weight, and body surface area, food consumption rate of daily intake of radioactive substances and exposure dose from natural radiation. (Author)

  13. Draft Air Pathway Report: Phase 1 of the Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-20

    This report summarizes the air pathway portion of the first phase of the Hanford Environmental Dose Reconstruction (HEDR) Project, conducted by Battelle staff at the Pacific Northwest Laboratory under the direction of an independent Technical Steering Panel. The HEDR Project is estimating historical radiation doses that could have been received by populations near the Department of Energy's Hanford Site, in southeastern Washington State. Phase 1 of the air-pathway dose reconstruction sought to determine whether dose estimates could be calculated for populations in the 10 counties nearest the Hanford Site from atmospheric releases of iodine-131 from the site from 1944--1947. Phase 1 demonstrated the following: HEDR-calculated source-term estimates of iodine-131 releases to the atmosphere were within 20% of previously published estimates; calculated vegetation concentrations of iodine-131 agree well with previously published measurements; the highest of the Phase 1 preliminary dose estimates to the thyroid are consistent with independent, previously published estimates of doses to maximally exposed individuals; and relatively crude, previously published measurements of thyroid burdens for Hanford workers are in the range of average burdens that the HEDR model estimated for similar reference individuals'' for the period 1944--1947. 4 refs., 10 figs., 9 tabs.

  14. Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values.

    Science.gov (United States)

    McMillan, Kyle; Bostani, Maryam; Cagnon, Christopher H; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H; McNitt-Gray, Michael F

    2017-08-01

    The vast majority of body CT exams are performed with automatic exposure control (AEC), which adapts the mean tube current to the patient size and modulates the tube current either angularly, longitudinally or both. However, most radiation dose estimation tools are based on fixed tube current scans. Accurate estimates of patient dose from AEC scans require knowledge of the tube current values, which is usually unavailable. The purpose of this work was to develop and validate methods to accurately estimate the tube current values prescribed by one manufacturer's AEC system to enable accurate estimates of patient dose. Methods were developed that took into account available patient attenuation information, user selected image quality reference parameters and x-ray system limits to estimate tube current values for patient scans. Methods consistent with AAPM Report 220 were developed that used patient attenuation data that were: (a) supplied by the manufacturer in the CT localizer radiograph and (b) based on a simulated CT localizer radiograph derived from image data. For comparison, actual tube current values were extracted from the projection data of each patient. Validation of each approach was based on data collected from 40 pediatric and adult patients who received clinically indicated chest (n = 20) and abdomen/pelvis (n = 20) scans on a 64 slice multidetector row CT (Sensation 64, Siemens Healthcare, Forchheim, Germany). For each patient dataset, the following were collected with Institutional Review Board (IRB) approval: (a) projection data containing actual tube current values at each projection view, (b) CT localizer radiograph (topogram) and (c) reconstructed image data. Tube current values were estimated based on the actual topogram (actual-topo) as well as the simulated topogram based on image data (sim-topo). Each of these was compared to the actual tube current values from the patient scan. In addition, to assess the accuracy of each method in estimating

  15. Estimation of 1945 to 1957 food consumption. Hanford Environmental Dose Reconstruction Project: Draft

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D.M.; Bates, D.J.; Marsh, T.L.

    1993-03-01

    This report details the methods used and the results of the study on the estimated historic levels of food consumption by individuals in the Hanford Environmental Dose Reconstruction (HEDR) study area from 1945--1957. This period includes the time of highest releases from Hanford and is the period for which data are being collected in the Hanford Thyroid Disease Study. These estimates provide the food-consumption inputs for the HEDR database of individual diets. This database will be an input file in the Hanford Environmental Dose Reconstruction Integrated Code (HEDRIC) computer model that will be used to calculate the radiation dose. The report focuses on fresh milk, eggs, lettuce, and spinach. These foods were chosen because they have been found to be significant contributors to radiation dose based on the Technical Steering Panel dose decision level.

  16. Effective dose to staff from interventional procedures: Estimations from single and double dosimetry

    International Nuclear Information System (INIS)

    Kuipers, G.; Velders, X. L.

    2009-01-01

    The exposure of 11 physicians performing interventional procedures was measured by means of two personal dosemeters. One personal dosemeter was worn outside the lead apron and an additional under the lead apron. The study was set up in order to determine the added value of a dosemeter worn under the lead apron. With the doses measured, the effective doses of the physicians were estimated using an algorithm for single dosimetry and two algorithms for double dosimetry. The effective doses calculated with the single dosimetry algorithm ranged from 0.11 to 0.85 mSv in 4 weeks. With the double dosimetry algorithms, the effective doses ranged from 0.02 mSv to 0.47 mSv. The statistical analysis revealed no significant differences in the accuracy of the effective doses calculated with single or double dosimetry algorithms. It was concluded that the effective dose cannot be considered a more accurate estimate when two dosemeters are used instead of one. (authors)

  17. Radiochemical separation and effective dose estimation due to ingestion of 90Sr

    International Nuclear Information System (INIS)

    Ilic, Z.; Vidic, A.; Deljkic, D.; Sirko, D.; Zovko, E.; Samek, D.

    2009-01-01

    Since 2007. Institute for Public Health of Federation of Bosnia and Herzegovina-Radiation Protection Centre, within the framework of monitoring of radioactivity of environment carried out measurement of specific activity of 90 Sr content in selected food and water samples. The paper described the methods of measurement and radiochemical separation. Presented results, as average values of specific activity of 90 Sr, were used for estimation of effective dose due to ingestion of 90 Sr for 2007. and 2008. Estimated effective dose for 2007. due to ingestion of 90 Sr for adults was 1,36 μSv and 2,03 μSv for children (10 year old), and for 2008. 0,67 μSv (adults) and 1,01 μSv (children 10 year old). Estimated effective doses for 2007. and 2008. are varied because of different average specific activity radionuclide 90 Sr in selected samples of food, their number, species and origin. (author) [sr

  18. Internal dose estimates

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1977-01-01

    Internal doses, the procedures for making them and their significance has been reviewed. Effects of uranium, radium, lead-210, polonium-210, thorium in man are analysed based on data from tables and plots. Dosimetry of some ingested nuclides and inhalation dose due to radon-222, radon-220 and their daugther products are discussed [pt

  19. A comparison study of size-specific dose estimate calculation methods

    Energy Technology Data Exchange (ETDEWEB)

    Parikh, Roshni A. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Wien, Michael A.; Jordan, David W.; Ciancibello, Leslie; Berlin, Sheila C. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); Novak, Ronald D. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); Rebecca D. Considine Research Institute, Children' s Hospital Medical Center of Akron, Center for Mitochondrial Medicine Research, Akron, OH (United States); Klahr, Paul [CT Clinical Science, Philips Healthcare, Highland Heights, OH (United States); Soriano, Stephanie [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); University of Washington, Department of Radiology, Seattle, WA (United States)

    2018-01-15

    The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. Concordance correlation (ρ{sub c}) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDI{sub vol,} there was poor correlation, ρ{sub c}<0.77, with percentage differences between 20.8% and 51.0%. Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide

  20. Cost analysis of small hydroelectric power plants components and preliminary estimation of global cost

    International Nuclear Information System (INIS)

    Basta, C.; Olive, W.J.; Antunes, J.S.

    1990-01-01

    An analysis of cost for each components of Small Hydroelectric Power Plant, taking into account the real costs of these projects is shown. It also presents a global equation which allows a preliminary estimation of cost for each construction. (author)

  1. Dose estimate for personal music players including earphone sensitivity and characteristic

    DEFF Research Database (Denmark)

    Hammershøi, Dorte; Ordoñez Pizarro, Rodrigo Eduardo; Christensen, Anders Tornvig

    2016-01-01

    Personal music players can expose their listeners to high sound pressure levels over prolonged periods of time. The risk associated with prolonged listening is not readily available to the listener, and efforts are made to standardize dose estimates that may be displayed for the user. In the pres......Personal music players can expose their listeners to high sound pressure levels over prolonged periods of time. The risk associated with prolonged listening is not readily available to the listener, and efforts are made to standardize dose estimates that may be displayed for the user...... earphone measurements published in the past. The work is on-going....

  2. Testicular shield for para-aortic radiotherapy and estimation of gonad doses.

    Science.gov (United States)

    Ravichandran, R; Binukumar, J P; Kannadhasan, S; Shariff, M H; Ghamrawy, Kamal El

    2008-10-01

    For radiotherapy of para-aortic and abdominal regions in male patients, gonads are to be protected to receive less than 2% of the prescribed dose. A testicular shield was fabricated for abdominal radiotherapy with 15 MV X-rays ((Clinac 2300 CD, Varian AG) with low melting point alloy (Cerroband). The dimensions of the testicular shield were 6.5 cm diameter and 3.5 cm depth with 1.5 cm wall thickness. During treatment, this shield was held in position by a rectangular sponge and Styrofoam support. Phantom measurement was carried out with a humanoid phantom and a 0.6 cc ion chamber. The mean energy of the scattered photon was calculated for single scattering at selected distances from the beam edge and with different field dimensions. One patient received radiotherapy with an inverted Y field and gonad doses were estimated using calibrated thermo-luminescent detector (TLD) chips. Measured doses with the ion chamber were 7.1 and 3.5% of the mid-plane doses without a shield at 3 and 7.5 cm off-field respectively. These values decreased to 4.6 and 1.7% with the bottom shield alone, and to 1.7 and 0.8% with both bottom and top shields covering the ion chamber. The measured doses at the gonads during the patient's treatment were 0.5-0.92% for the AP field (0.74 +/- 0.17%, n = 5) and 0.5-1.2% for the PA field (0.88 +/- 0.24%, n = 5). The dose received by the testis for the full course of treatment was 32 cGy (0.8%) for a total mid-plane dose of 40 Gy. The first-scatter energy estimated at the gonads is around 1.14 MeV for a primary beam of 15 MV for a long axis dimension of 37 cm of primary field. During the patient's treatment, the estimated absorbed doses at the gonads were comparable with reported values in similar treatments. The testicular shield reported in this study is of light weight and could be used conveniently in treatments of abdominal fields.

  3. Testicular shield for para-aortic radiotherapy and estimation of gonad doses

    Directory of Open Access Journals (Sweden)

    Ravichandran R

    2008-01-01

    Full Text Available For radiotherapy of para-aortic and abdominal regions in male patients, gonads are to be protected to receive less than 2% of the prescribed dose. A testicular shield was fabricated for abdominal radiotherapy with 15 MV X-rays ((Clinac 2300 CD, Varian AG with low melting point alloy (Cerroband. The dimensions of the testicular shield were 6.5 cm diameter and 3.5 cm depth with 1.5 cm wall thickness. During treatment, this shield was held in position by a rectangular sponge and Styrofoam support. Phantom measurement was carried out with a humanoid phantom and a 0.6 cc ion chamber. The mean energy of the scattered photon was calculated for single scattering at selected distances from the beam edge and with different field dimensions. One patient received radiotherapy with an inverted Y field and gonad doses were estimated using calibrated thermo-luminescent detector (TLD chips. Measured doses with the ion chamber were 7.1 and 3.5% of the mid-plane doses without a shield at 3 and 7.5 cm off-field respectively. These values decreased to 4.6 and 1.7% with the bottom shield alone, and to 1.7 and 0.8% with both bottom and top shields covering the ion chamber. The measured doses at the gonads during the patient′s treatment were 0.5-0.92% for the AP field (0.74 ± 0.17%, n = 5 and 0.5-1.2% for the PA field (0.88 ± 0.24%, n = 5. The dose received by the testis for the full course of treatment was 32 cGy (0.8% for a total mid-plane dose of 40 Gy. The first-scatter energy estimated at the gonads is around 1.14 MeV for a primary beam of 15 MV for a long axis dimension of 37 cm of primary field. During the patient′s treatment, the estimated absorbed doses at the gonads were comparable with reported values in similar treatments. The testicular shield reported in this study is of light weight and could be used conveniently in treatments of abdominal fields.

  4. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose-effect curve)

    International Nuclear Information System (INIS)

    Al-Achkar, W.

    2001-09-01

    In order to draw a dose-effect curve, experimentally gamma ray induced chromosomal aberrations in human peripheral lymphocytes from eight healthy people were studied. Samples from 4 males and 4 females were irradiated in tubes with 0.15, 0.25, 0.5, 1, 1.5, 2, 2.5 gray of gamma ray (Co 60 at dose rate 0.3 Gy/min). Irradiated and control samples were incubated in 37 centigrade for 48 hours cell cultures. Cell cultures then were stopped and metaphases spread, Giemsa stained to score the induced chromosomal aberrations. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics + rings and total numbers of breaks in cell for each individual or for all people were drawn. An increase of all chromosomal aberrations types with the elevation of the doses was observed. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  5. A preliminary assessment of the radiological impact of the Chernobyl reactor accident on the population of the European Community

    International Nuclear Information System (INIS)

    Morrey, M.; Brown, J.; Williams, J.A.; Crick, M.J.; Simmonds, J.R.; Hill, M.D.

    1988-01-01

    Following the Chernobyl accident the Commission of the European Communities asked the National Radiological Protection Board to carry out a preliminary assessment of the radiological consequences of the accident on the population of the European Community (EC). The aim of the study was to review information on the environmental contamination measured in member states of the EC; to make a preliminary assessment of individual and population doses for each country; to make an estimate of the resulting health impact and to indicate the effects of the various countermeasures taken by member states in terms of the reductions in both individual and population exposure which they produced. All of the main pathways by which people have been and will be exposed to radiation as a result of the accident were included in the assessment. The impact estimate is based on environmental measurements made during the month after the accident, and on calculations made using mathematical models of radionuclide transfer through the environment. The calculated effective doses to average individuals in EC countries from exposure over the next 50 years range from 0.3 μSv (in Portugal) to between about 300 and 500 μSv (in the FRG, Italy and Greece). The total collective effective dose to the population of EC countries, integrated over all time, is estimated to be about 80 000 man Sv. This may be compared to the collective effective dose from natural background radiation of about 500 000 man Sv every year. In some countries, the restrictions placed on consumption of some foods are estimated to have been effective in reducing doses to the most exposed individuals; the reduction being up to about a factor of 2. The results presented in this paper should therefore be regarded as preliminary

  6. Estimation of exposed dose, 1

    International Nuclear Information System (INIS)

    Okajima, Shunzo

    1976-01-01

    Radioactive atomic fallouts in Nishiyama district of Nagasaki Prefecture are reported on the basis of the survey since 1969. In 1969, the amount of 137 Cs in the body of 50 inhabitants in Nishiyama district was measured using human counter, and was compared with that of non-exposured group. The average value of 137 Cs (pCi/kg) was higher in inhabitants in Nishiyama district (38.5 in men and 24.9 in females) than in the controls (25.5 in men and 14.9 in females). The resurvey in 1971 showed that the amount of 137 Cs was decreased to 76% in men and 60% in females. When the amount of 137 Cs in the body was calculated from the chemical analysis of urine, it was 29.0 +- 8.2 in men and 29.4 +- 26.2 in females in Nishiyama district, and 29.9 +- 8.2 in men and 29.4 +- 11.7 in females in the controls. The content of 137 Cs in soils and crops (potato etc.) was higher in Nishiyama district than in the controls. When the internal exposure dose per year was calculated from the amount of 137 Cs in the body in 1969, it was 0.29 mrad/year in men and 0.19 mrad/year in females. Finally, the internal exposure dose immediately after the explosion was estimated. (Serizawa, K.)

  7. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, Joshua, E-mail: grimes.joshua@mayo.edu [Department of Physics and Astronomy, University of British Columbia, Vancouver V5Z 1L8 (Canada); Celler, Anna [Department of Radiology, University of British Columbia, Vancouver V5Z 1L8 (Canada)

    2014-09-15

    Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90

  8. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT

    International Nuclear Information System (INIS)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J.; Maentele, Werner; Bauer, Ralf W.

    2012-01-01

    Highlights: ► The dual-energy protocol delivers the lowest effective dose of the investigated protocols for standard chest CT examinations, thus enabling functional imaging (like dual-energy perfusion) and can produce weighted images without dose penalty. ► The high-pitch protocol goes along with a 16% increase in dose compared to the standard 120 kV protocol and thus should preferably be used in pediatric, acute care settings (e.g. pulmonary embolism, aortic dissection and the like) or restless patients. ► The difference in effective dose estimates between ICRP 60 and 103 is minimal. ► Tube potential definitely has an effect on estimates of effective dose. - Abstract: Purpose: To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Materials and methods: Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014 mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120 kV, (2) single-source 100 kV, (3) high-pitch 120 kV, and (4) dual-energy with 100/Sn140 kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. Results: DLP-based estimates differed by 4.5–16.56% and 5.2–15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04 m

  9. Rapid analysis of key radionuclides in urine and estimation of internal dose for nuclear accident emergency

    International Nuclear Information System (INIS)

    Zhao Shuquan; Hu Heping; Wu Mingyu; Zhu Guoying; Huang Shibin; Liu Shiming

    2005-01-01

    Objective: To estimate the internal doses of a Chinese visiting scholar in the Chernobyl accident. Methods: The contents of 134 Cs and 137 Cs in urine were measured using a Ge(Li) γ-spectrometer. Their internal doses were estimated according to ICRP reports. Dose review of 131I was performed referring to UNSCEAR 2000 report. Results: The effective dose equivalent from 134 Cs, 137 Cs and 131 I were 66 μSv, 88 μSv and 1728 μSv respectively. Their summation was 1.9 mSv. Conclusion: The internal dose from 131 I was 10 times higher than that from 134 Cs and 137 Cs. So, the earlier estimation of internal doses for 131 I is significant in evaluation on radiation injuries of a nuclear reactor accident. (authors)

  10. Generalized concept for the estimation of body dose for radiation workers exposed to external #betta#-rays

    International Nuclear Information System (INIS)

    Piesch, E.; Boehm, J.; Heinzelmann, M.

    1983-01-01

    In radiation protection monitoring the need exists for an estimation of body dose due to external #betta#-rays, for instance if the #betta#-dose rate at the working area is expected to be high according to the data of source activity or room contamination, the indicated dose values of a personal dosemeter exceed the operational limit for the organ or tissue depth of interest, or a person was exposed to a significant dose. On behalf of the Federal Ministry of the Interior, Federal Republic of Germany, a guideline is now under preparation which offers a standardized concept of the estimation of #betta#-doses in personnel monitoring. The calculation models discussed here will be used as a basis for any case of external #betta#-irradiation where, in connection with the German Radiation Protection Ordinance, the ICRP dose equivalent limits are reached or the dosemeter readings are not representative for an individual exposure. The generalized concept discussed in the paper relates to: the calculation of #betta#-dose on the basis of source activity or spectral particle fluence and takes into account the special cases of point sources, area sources and volume sources; the estimation of body dose on the basis of calculated data or measured results from area or personnel monitoring, taking into account the dose equivalent in different depths of tissue, in particular the dose equivalent to the skin, the lens of the eye and other organs; and finally the estimation of skin dose due to the contamination of the skin surface. Basic reference data are presented in order to estimate the dose equivalent of interest which varies significantly in the #betta#-radiation field as a function of the maximum #betta#-energy, distance to the source, size of the source, activity per area for surface contamination and activity per volume for air contamination

  11. Variability in dose estimates associated with the food-chain transport and ingestion of selected radionuclides

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Gardner, R.H.; Eckerman, K.F.

    1982-06-01

    Dose predictions for the ingestion of 90 Sr and 137 Cs, using aquatic and terrestrial food chain transport models similar to those in the Nuclear Regulatory Commission's Regulatory Guide 1.109, are evaluated through estimating the variability of model parameters and determining the effect of this variability on model output. The variability in the predicted dose equivalent is determined using analytical and numerical procedures. In addition, a detailed discussion is included on 90 Sr dosimetry. The overall estimates of uncertainty are most relevant to conditions where site-specific data is unavailable and when model structure and parameter estimates are unbiased. Based on the comparisons performed in this report, it is concluded that the use of the generic default parameters in Regulatory Guide 1.109 will usually produce conservative dose estimates that exceed the 90th percentile of the predicted distribution of dose equivalents. An exception is the meat pathway for 137 Cs, in which use of generic default values results in a dose estimate at the 24th percentile. Among the terrestrial pathways of exposure, the non-leafy vegetable pathway is the most important for 90 Sr. For 90 Sr, the parameters for soil retention, soil-to-plant transfer, and internal dosimetry contribute most significantly to the variability in the predicted dose for the combined exposure to all terrestrial pathways. For 137 Cs, the meat transfer coefficient the mass interception factor for pasture forage, and the ingestion dose factor are the most important parameters. The freshwater finfish bioaccumulation factor is the most important parameter for the dose prediction of 90 Sr and 137 Cs transported over the water-fish-man pathway

  12. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives; Primo interconfronto italiano sulle metodiche di valutazione di dose da contaminazione interna: risultati e prospettive

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1998-07-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated. [Italian] Vengono riportati i risultati delle valutazioni di Intake e di equivalente di dose nei centri MIDIA (coordinamento dei WBC operanti in Italia) per effettuare un interconfronto sui metodi di valutazione di dose da contaminazione interna utilizzando casi di studio reperiti in ambiente europeo. Vengono indicate le prospettive per la valutazione della qualita' della stima di dose in dosimetria interna.

  13. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Yang, K; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

  14. Estimation of absorbed dose in cell nuclei due to DNA-bound /sup 3/H

    Energy Technology Data Exchange (ETDEWEB)

    Saito, M; Ishida, M R; Streffer, C; Molls, M

    1985-04-01

    The average absorbed dose due to DNA-bound /sup 3/H in a cell nucleus was estimated by a Monte Carlo simulation for a model nucleus which was assumed to be spheroidal. The volume of the cell nucleus was the major dose-determining factor for cell nuclei which have the same DNA content and the same specific activity of DNA. This result was applied to estimating the accumulated dose in the cell nuclei of organs of young mice born from mother mice which ingested /sup 3/H-thymidine with drinking water during pregnancy. The values of dose-modifying factors for the accumulated dose due to DNA-bound /sup 3/H compared to the dose due to an assumed homogenous distribution of /sup 3/H in organ were found to be between about 2 and 6 for the various organs.

  15. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    A method has been devised to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats, and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, some quantitative problems connected with estimating low-dose effects from other disciplines have been reviewed, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to human is discussed

  16. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    We have devised a method to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, researchers have reviewed some quantitative problems connected with estimating low-dose effects from other disciplines, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to humans is discussed

  17. Radiation exposure to examiners and patients during therapeutic ERCP: Dose optimisation and risk estimation

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.; Paroutoglou, G.; Kapatenakis, A.; Kapsoritakis, A.; Potamianos, S.; Vlychou, M.; Fezoulidis, I.

    2008-01-01

    Aim: This study intended to optimise the radiation dose during therapeutic ERCP, and to estimate the risk for examiners and patients, to compare the doses based on available data obtained by other researchers and reference levels recommended by international organizations, and to evaluate the technique applied in order to reduce patient and examiners doses. Materials and Methods: 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42). Thermoluminescent dosimeters (TLD) were used to measure the staff and patients entrance surface dose (ESD) at different body sites. Results: The mean ESD, exit and thyroid surface dose per procedure was estimated to be 68.75 mGy, 3.45 mGy and 0.67 mGy, respectively. The mean patient effective dose was 3.44 mSv, and the cancer risk per procedure was estimated to be 190 x10 -6 . The effective dose for the first, second and third examiner was 0.4 μSv, 0.2 μSv and 5.0 μSv, respectively. Conclusion: The patient dose can be optimized by the presence of two experienced examiners and reduction of radiographic images. The examiners should use a wrap around lead apron since the highest dose originating from the X-ray tube, is incident on their side and back. The current formulae, which exist, underestimate the effective dose to the examiners, when they are applied for ERCP procedures. For both patients and examiners, our results were up to 60% lower compared to the lowest values found in previous studies. (authors)

  18. Development of transmission dose estimation algorithm for in vivo dosimetry in high energy radiation treatment

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Shin, Kyo Chul; Hun, Soon Nyung; Woo, Hong Gyun; Ha, Sung Whan; Lee, Hyoung Koo

    2004-01-01

    In vivo dosimetry is very important for quality assurance purpose in high energy radiation treatment. Measurement of transmission dose is a new method of in vivo dosimetry which is noninvasive and easy for daily performance. This study is to develop a tumor dose estimation algorithm using measured transmission dose for open radiation field. For basic beam data, transmission dose was measured with various field size (FS) of square radiation field, phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. By using regression analysis of measured basic beam data, a transmission dose estimation algorithm was developed. Accuracy of the algorithm was tested with flat solid phantom with various thickness in various settings of rectangular fields and various PCD. In our developed algorithm, transmission dose was equated to quadratic function of log(A/P) (where A/P is area-perimeter ratio) and the coefficients of the quadratic functions were equated to tertiary functions of PCD. Our developed algorithm could estimate the radiation dose with the errors within ±0.5% for open square field, and with the errors within ±1.0% for open elongated radiation field. Developed algorithm could accurately estimate the transmission dose in open radiation fields with various treatment settings of high energy radiation treatment. (author)

  19. Radiation dose estimation from foods due to the accident of TEPCO Fukushima Daiichi Nuclear Power Station

    International Nuclear Information System (INIS)

    Yamaguchi, Ichiro

    2012-01-01

    Explained are the purpose of dose assessment, its methods, actual radionuclide levels in food, amounts of food intake, dose estimated hitherto, dose in the future, dose estimated by total food studies, and problems of assessing the dose from food, all of which Tokyo Electric Power Company (TEPCO) Power Station Accident has raised. Dose derived from food can be estimated by the radioactivity measured in each food material and in its combined amounts or in actually cooked food. Amounts of radioactive materials ingested in the body can be measured externally or by bioassay. Japan MHLW published levels of radioactivity in vegetables', fruits, marine products and meats from Mar. 2011, of which time course pattern has been found different each other within and between month(s). Dose due to early exposure in the Accident can be estimated by the radioactivity levels above and data concerning the amounts of food intake summarized by National Institute of Health and Nutrition in 2010 and other institutions. For instance, the thyroid tissue equivalent dose by I-131 in a 1 year old child is estimated to be 1.1-5 mSv depending on the assumed data for calculation, in the first month after the Accident when ICRP tissue equivalent dose coefficient 3.7 x 10-6 Sv/Bq is used. In the future (later than Apr. 2012), new standard limits of radiocesium levels in milk/its products and foods for infant and in other general foods are to be defined 50 and 100 Bq/kg, respectively. The distribution of committed effective doses by radiocesium (mSv/y food intake) are presented as an instance, where it is estimated by 1 million stochastic simulations using 2 covariates of Cs-134, -137 levels (as representative nuclides under regulation) in food and of daily food intake. In dose prediction, conjecturing the behavior of environmental radionuclides and the time of resume of primary industries would be necessary. (T.T.)

  20. Warfarin Dosing Algorithms Underpredict Dose Requirements in Patients Requiring ≥7 mg Daily: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Saffian, S M; Duffull, S B; Wright, Dfb

    2017-08-01

    There is preliminary evidence to suggest that some published warfarin dosing algorithms produce biased maintenance dose predictions in patients who require higher than average doses. We conducted a meta-analysis of warfarin dosing algorithms to determine if there exists a systematic under- or overprediction of dose requirements for patients requiring ≥7 mg/day across published algorithms. Medline and Embase databases were searched up to September 2015. We quantified the proportion of over- and underpredicted doses in patients whose observed maintenance dose was ≥7 mg/day. The meta-analysis included 47 evaluations of 22 different warfarin dosing algorithms from 16 studies. The meta-analysis included data from 1,492 patients who required warfarin doses of ≥7 mg/day. All 22 algorithms were found to underpredict warfarin dosing requirements in patients who required ≥7 mg/day by an average of 2.3 mg/day with a pooled estimate of underpredicted doses of 92.3% (95% confidence interval 90.3-94.1, I 2 = 24%). © 2017 American Society for Clinical Pharmacology and Therapeutics.

  1. Estimation of population dose and risk to holding assistants from veterinary X-ray examination in Japan

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Suganuma, Tunenori; Shida, Takuo

    1989-01-01

    For the estimation of the population doses and risks of stochastic effects to assistants who hold animals during veterinary X-ray examination, a random survey of hospitals and clinics was carried out concerning age distribution of such assistants by groups of facilities. The average organ and tissue dose per examination was evaluated from the experimental data using mean technical factors such as X-ray tube voltage, tube current and field size based on the results of a nationwide survey. The population doses to the assistants were calculated to be about 14 nSv per person per year for the genetically significant dose, 3.5 nSv per person per year for per caput mean marrow dose, 3.3 nSv for the leukemia significant dose and 4.5 nSv for the malignant significant dose, respectively. The total risk of stochastic effects to the Japanese population from holding assistants was estimated using population data and it was estimated to be less than one person per year, but the cancer risks to a number of the assistants were estimated to be more than 4 x 10 -5 . (author)

  2. Small field depth dose profile of 6 MV photon beam in a simple air-water heterogeneity combination: A comparison between anisotropic analytical algorithm dose estimation with thermoluminescent dosimeter dose measurement.

    Science.gov (United States)

    Mandal, Abhijit; Ram, Chhape; Mourya, Ankur; Singh, Navin

    2017-01-01

    To establish trends of estimation error of dose calculation by anisotropic analytical algorithm (AAA) with respect to dose measured by thermoluminescent dosimeters (TLDs) in air-water heterogeneity for small field size photon. TLDs were irradiated along the central axis of the photon beam in four different solid water phantom geometries using three small field size single beams. The depth dose profiles were estimated using AAA calculation model for each field sizes. The estimated and measured depth dose profiles were compared. The over estimation (OE) within air cavity were dependent on field size (f) and distance (x) from solid water-air interface and formulated as OE = - (0.63 f + 9.40) x2+ (-2.73 f + 58.11) x + (0.06 f2 - 1.42 f + 15.67). In postcavity adjacent point and distal points from the interface have dependence on field size (f) and equations are OE = 0.42 f2 - 8.17 f + 71.63, OE = 0.84 f2 - 1.56 f + 17.57, respectively. The trend of estimation error of AAA dose calculation algorithm with respect to measured value have been formulated throughout the radiation path length along the central axis of 6 MV photon beam in air-water heterogeneity combination for small field size photon beam generated from a 6 MV linear accelerator.

  3. Prospective estimation of organ dose in CT under tube current modulation

    International Nuclear Information System (INIS)

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Samei, Ehsan

    2015-01-01

    Purpose: Computed tomography (CT) has been widely used worldwide as a tool for medical diagnosis and imaging. However, despite its significant clinical benefits, CT radiation dose at the population level has become a subject of public attention and concern. In this light, optimizing radiation dose has become a core responsibility for the CT community. As a fundamental step to manage and optimize dose, it may be beneficial to have accurate and prospective knowledge about the radiation dose for an individual patient. In this study, the authors developed a framework to prospectively estimate organ dose for chest and abdominopelvic CT exams under tube current modulation (TCM). Methods: The organ dose is mainly dependent on two key factors: patient anatomy and irradiation field. A prediction process was developed to accurately model both factors. To model the anatomical diversity and complexity in the patient population, the authors used a previously developed library of computational phantoms with broad distributions of sizes, ages, and genders. A selected clinical patient, represented by a computational phantom in the study, was optimally matched with another computational phantom in the library to obtain a representation of the patient’s anatomy. To model the irradiation field, a previously validated Monte Carlo program was used to model CT scanner systems. The tube current profiles were modeled using a ray-tracing program as previously reported that theoretically emulated the variability of modulation profiles from major CT machine manufacturers Li et al., [Phys. Med. Biol. 59, 4525–4548 (2014)]. The prediction of organ dose was achieved using the following process: (1) CTDI vol -normalized-organ dose coefficients (h organ ) for fixed tube current were first estimated as the prediction basis for the computational phantoms; (2) each computation phantom, regarded as a clinical patient, was optimally matched with one computational phantom in the library; (3) to

  4. Combined methodology for estimating dose rates and health effects from exposure to radioactive pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, D.E. Jr.; Leggett, R.W.; Yalcintas, M.G.

    1980-12-01

    The work described in the report is basically a synthesis of two previously existing computer codes: INREM II, developed at the Oak Ridge National Laboratory (ORNL); and CAIRD, developed by the Environmental Protection Agency (EPA). The INREM II code uses contemporary dosimetric methods to estimate doses to specified reference organs due to inhalation or ingestion of a radionuclide. The CAIRD code employs actuarial life tables to account for competing risks in estimating numbers of health effects resulting from exposure of a cohort to some incremental risk. The combined computer code, referred to as RADRISK, estimates numbers of health effects in a hypothetical cohort of 100,000 persons due to continuous lifetime inhalation or ingestion of a radionuclide. Also briefly discussed in this report is a method of estimating numbers of health effects in a hypothetical cohort due to continuous lifetime exposure to external radiation. This method employs the CAIRD methodology together with dose conversion factors generated by the computer code DOSFACTER, developed at ORNL; these dose conversion factors are used to estimate dose rates to persons due to radionuclides in the air or on the ground surface. The combination of the life table and dosimetric guidelines for the release of radioactive pollutants to the atmosphere, as required by the Clean Air Act Amendments of 1977.

  5. Estimated collective effective dose to the population from radiological examinations in Slovenia

    Science.gov (United States)

    Zontar, Dejan; Zdesar, Urban; Kuhelj, Dimitrij; Pekarovic, Dean; Skrk, Damijan

    2015-01-01

    Background The aim of the study was to systematically evaluate population exposure from diagnostic and interventional radiological procedures in Slovenia. Methods The study was conducted in scope of the “Dose Datamed 2” project. A standard methodology based on 20 selected radiological procedures was adopted. Frequencies of the procedures were determined via questionnaires that were sent to all providers of radiological procedures while data about patient exposure per procedure were collected from existing databases. Collective effective dose to the population and effective dose per capita were estimated from the collected data (DLP for CT, MGD for mammography and DAP for other procedures) using dose conversion factors. Results The total collective effective dose to the population from radiological in 2011 was estimated to 1300 manSv and an effective dose per capita to 0.6 mSv of which approximately 2/3 are due to CT procedures. Conclusions The first systematic study of population exposure to ionising radiation from radiological procedures in Slovenia was performed. The results show that the exposure in Slovenia is under the European average. It confirmed large contributions of computed tomography and interventional procedures, identifying them as the areas that deserve special attention when it comes to justification and optimisation. PMID:25810709

  6. Estimation of staff doses in complex radiological examinations using a Monte Carlo computer code

    International Nuclear Information System (INIS)

    Vanhavere, F.

    2007-01-01

    The protection of medical personnel in interventional radiology is an important issue of radiological protection. The irradiation of the worker is largely non-uniform, and a large part of his body is shielded by a lead apron. The estimation of effective dose (E) under these conditions is difficult and several approaches are used to estimate effective dose involving such a protective apron. This study presents a summary from an extensive series of simulations to determine scatter-dose distribution around the patient and staff effective dose from personal dosimeter readings. The influence of different parameters (like beam energy and size, patient size, irradiated region, worker position and orientation) on the staff doses has been determined. Published algorithms that combine readings of an unshielded and a shielded dosimeter to estimate effective dose have been applied and a new algorithm, that gives more accurate dose estimates for a wide range of situations was proposed. A computational approach was used to determine the dose distribution in the worker's body. The radiation transport and energy deposition was simulated using the MCNP4B code. The human bodies of the patient and radiologist were generated with the Body Builder anthropomorphic model-generating tool. The radiologist is protected with a lead apron (0.5 mm lead equivalent in the front and 0.25 mm lead equivalent in the back and sides) and a thyroid collar (0.35 mm lead equivalent). The lower-arms of the worker were folded to simulate the arms position during clinical examinations. This realistic situation of the folded arms affects the effective dose to the worker. Depending on the worker position and orientation (and of course the beam energy), the difference can go up to 25 percent. A total of 12 Hp(10) dosimeters were positioned above and under the lead apron at the neck, chest and waist levels. Extra dosimeters for the skin dose were positioned at the forehead, the forearms and the front surface of

  7. Estimation of population doses from diagnostic medical examinations in Japan, 1974, (4)

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Maruyama, Takashi; Kumamoto, Yoshikazu

    1976-01-01

    In fetus exposed in utero to diagnostic x-rays for the medical examinations of the mother, the absorbed dose has been estimated on the basis of a 1974 nation wide radiological survey. The results of the survey showed that the number of radiographs per year connected with pregnant women was 0.32 million for chest examination excluding mass surveys. 0.29 million for obstetrical examinations including pelvimetry, and 0.21 million for abdominal and pelvic examinations with a total of 0.82 million. The dose absorbed in the fetus was measured with an ionization chamber placed at the hypothetical center of the fetus in an ''average woman'' Rando phantom in which a maternal body was simulated by adding MixDp materials. ''The collective dose'' to the fetus in the pregnant women receiving a given type of examination was calculated from the number of radiographs per year connected with the pregnant women and the fetal doses. The percapita mean marrow dose (CMD), the leukemia significant dose (LSD) and the genetically significant dose (GSD) for the fetus were determined from the collective dose, taking into account the birth expectancy, the child expectancy, life expectancy and significant factor for the fetus. The collective dose to the fetus was estimated to be 9.3 x 10 4 man rad per year. The resultant values of CMD, LSD and GSD were 0.81 mrad per year, 0.79 mrad per person per year and 1.44 mrad per person per year, respectively. (Evans, J.)

  8. Estimation of eye lens doses received by pediatric interventional cardiologists.

    Science.gov (United States)

    Alejo, L; Koren, C; Ferrer, C; Corredoira, E; Serrada, A

    2015-09-01

    Maximum Hp(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Radiation dose to the patient in radionuclide studies

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1981-01-01

    In medical radionuclide studies, the radiation risk has to be considered in addition to the general risk of administering a pharmaceutical. As radiation exposure is an essential factor in radiation risk estimation, some aspects of internal dose calculation, including radiation risk assessments, are treated. The formalism of current internal dose calculation is presented. The input data, especially the residence time and the absorbed dose per transformation, their origin and accuracy are discussed. Results of internal dose calculations for the ten most frequently used radionuclide studies are presented as somatically effective dose equivalents. The accuracy of internal dose calculation is treated in detail by considering the biokinetics of the radiopharmaceutical, the phantoms used for dose calculations, the absorbed dose per transformation, the administered activity, and the transfer of the dose, calculated for a phantom, to the patient. The internal dose calculated for a reference phantom may be assumed to be in accordance with the actual patient dose within a range described by a factor of about two to three. Finally, risk estimates for nuclear medicine procedures are quantified, being generally of sixth order. The radiation risk from the radioiodine test is comparably higher, but probably lower than calculated according to the UNSCEAR risk coefficients. However, further studies are needed to confirm these preliminary results and to improve the quantification of the radiation risk from the medical use of radionuclides. (author)

  10. Preliminary report about nuclear accident of Chernobylsk reactor

    International Nuclear Information System (INIS)

    Oliveira, A.R. de.

    1986-07-01

    The preliminary report of nuclear accident at Chernobyl, in URSS is presented. The Chernobyl site is located geographically and the RBMK type reactors - initials of russian words which mean high power pressure tube reactors are described. The conditions of reactor operation in beginning of accident, the events which lead to reactor destruction, the means to finish the fire, the measurements adopted by Russian in the accident location, the estimative of radioactive wastes, the meteorological conditions during the accident, the victims and medical assistence, the sanitary aspects and consequences for population, the evaluation of radiation doses received at small and medium distance and the estimative of reffered doses by population attained are presented. The official communication of Russian Minister Council and the declaration of IAEA general manager during a collective interview in Moscou are annexed. (M.C.K.) [pt

  11. Estimation of dose distribution in occupationally exposed individuals to FDG-{sup 18}F

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Isabelle V. Batista de; Cabral, Manuela O. Monteiro; Vieira, Jose Wilson, E-mail: ilacerda.bolsista@cnen.gov.br, E-mail: manuela.omc@gmail.com [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Oliveira, Mercia Liane de; Andrade Lima, Fernando R. de, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    The use of unsealed radiation sources in nuclear medicine can lead to important incorporation of radionuclides, especially for occupationally exposed individuals (OEIs) during production and handling of radiopharmaceuticals. In this study, computer simulation was proposed as an alternative methodology for evaluation of the absorbed dose distribution and for the effective dose value in OEIs. For this purpose, the Exposure Computational Model (ECM) which is named as FSUP (Female Adult Mesh - supine) were used. This ECM is composed of: voxel phantom FASH (Female Adult MeSH) in the supine position, the MC code EGSnrc and an algorithm simulator of general internal source. This algorithm was modified to adapt to specific needs of the positron emission from FDG-{sup 18}F. The obtained results are presented as absorbed dose/accumulated activity. To obtain the absorbed dose distribution it was necessary to use accumulative activity data from the in vivo bioassay. The absorbed dose distribution and the value of estimated effective dose in this study did not exceed the limits for occupational exposure. Therefore, the creation of a database with the distribution of accumulated activity is suggested in order to estimate the absorbed dose in radiosensitive organs and the effective dose for OEI in similar environment. (author)

  12. The D1 method: career dose estimation from a combination of historical monitoring data and a single year's dose data

    International Nuclear Information System (INIS)

    Sont, W.N.

    1995-01-01

    A method is introduced to estimate career doses from a combination of historical monitoring data and a single year's dose data. This method, called D1 eliminates the bias arising from incorporating historical dose data from times when occupational doses were generally much higher than they are today. Doses calculated by this method are still conditional on the preservation of the status quo in the effectiveness of radiation protection. The method takes into account the variation of the annual dose, and of the probability of being monitored, with the time elapsed since the start of a career. It also allows for the calculation of a standard error of the projected career dose. Results from recent Canadian dose data are presented. (author)

  13. Improved dose estimates for nuclear criticality accidents

    International Nuclear Information System (INIS)

    Wilkinson, A.D.; Basoglu, B.; Bentley, C.L.; Dunn, M.E.; Plaster, M.J.; Dodds, H.L.; Yamamoto, T.

    1995-01-01

    Slide rules are improved for estimating doses and dose rates resulting from nuclear criticality accidents. The original slide rules were created for highly enriched uranium solutions and metals using hand calculations along with the decades old Way-Wigner radioactive decay relationship and the inverse square law. This work uses state-of-the-art methods and better data to improve the original slide rules and also to extend the slide rule concept to three additional systems; i.e., highly enriched (93.2 wt%) uranium damp (H/ 235 U = 10) powder (U 3 O 8 ) and low-enriched (5 wt%) uranium mixtures (UO 2 F 2 ) with a H/ 235 U ratio of 200 and 500. Although the improved slide rules differ only slightly from the original slide rules, the improved slide rules and also the new slide rules can be used with greater confidence since they are based on more rigorous methods and better nuclear data

  14. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    Science.gov (United States)

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  15. Current estimates of radiation risks and implications for dose limits

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1989-01-01

    The publication of the 1988 report of UNSCEAR represents a major step forward in that there is an international consensus on the estimation of risk from exposure to ionising radiation. The estimates of fatal cancers in the UNSCEAR report are up to 4 times the values in the 1977 review. This paper will describe the reasons for the increase, the remaining uncertainties and the implications for dose limits in occupational and public exposure. (author)

  16. Long-term intercomparison of Spanish environmental dosimetry services. Study of transit dose estimations

    International Nuclear Information System (INIS)

    Duch, Ma Amor; Carlos Saez-Vergara, Jose; Ginjaume, Merce; Gomez, Candelas; Maria Gonzalez-Leiton, Ana; Herrero, Javier; Jose de Lucas, Ma; Rodriguez, Rafael; Marugan, Immaculada; Salas, Rosario

    2008-01-01

    This paper presents the layout and results of a three-year follow-up of a national intercomparison campaign organized on a voluntary basis among the Spanish Laboratories in charge of environmental monitoring at and in the vicinity of Spanish nuclear installations. The dosemeters were exposed in the field at an environmental reference station with a known ambient dose equivalent, and controlled meteorological parameters. The study aimed at verifying the consistency of the different laboratories in estimating the ambient dose equivalent in realistic fields and to evaluate the influence of two different procedures to estimate the transit dose during the transfer of the dosemeters both from and to the dosimetric laboratory and the monitored site. All the results were within 20% of the reference doses for all the dosemeters tested, and in most cases they were within 10%

  17. Estimation of breast dose and cancer risk in chest and abdomen CT procedures

    International Nuclear Information System (INIS)

    Eltahir, Suha Abubaker Ali

    2013-05-01

    The use of CT in medical diagnosis delivers radiation doses to patents that are higher than those from other radiological procedures. Lack of optimized protocols be an additional source of increased dose in developing countries. The aims of this study are first, to measure patient doses during CT chest and abdomen procedures, second, to estimate the radiation dose to the breast, and third to quantify the radiation risks during the procedures. Patient doses from two common CT examinations were obtained from four hospitals in Khartoum.The patient doses were estimated using measurement of CT dose indexes (CTDI), exposure-related parameters, and the IMPACT spreadsheet based on NRPB conversion factors. A large variation of mean organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scanner type. The largest range was found for CT of the chest, for which the dose varied from 2.3 to 47 (average 24.7) mSv and for abdomen CT, it was 1.6 to 18.8 (average 10.2) mSv. Radiation dose to the breast ranged from 1.6 to 32.9 mSv for the chest and 1.1 to 13.2 mSv for the abdomen. The radiation risk per procedure was high. The obtained values were mostly higher than the values of organ doses reported from the other studies. It was concluded that current clinical chest and abdomen protocols result in variable radiation doses to the breast. The magnitude of exposure may have implications for imaging strategies.(Author)

  18. Estimation of radionuclide ingestion: Lessons from dose reconstruction for fallout from the Nevada Test Site

    International Nuclear Information System (INIS)

    Breshears, D.D.; Whicker, F.W.; Kirchner, T.B.; Anspaugh, L.R.

    1994-01-01

    The United States conducted atmospheric testing of nuclear devices at the Nevada Test Site from 1951 through 1963. In 1979 the U.S. Department of Energy established the Off-Site Radiation Exposure Review Project to compile a data base related to health effects from nuclear testing and to reconstruct doses to public residing off of the Nevada Test Site. This project is the most comprehensive dose reconstruction project to date, and, since similar assessments are currently underway at several other locations within and outside the U.S., lessons from ORERP can be valuable. A major component of dose reconstruction is estimation of dose from radionuclide ingestion. The PATHWAY food-chain model was developed to estimate the amount of radionuclides ingested. For agricultural components of the human diet, PATHWAY predicts radionuclide concentrations and quantities ingested. To improve accuracy and model credibility, four components of model analysis were conducted: estimation of uncertainty in model predictions, estimation of sensitivity of model predictions to input parameters, and testing of model predictions against independent data (validation), and comparing predictions from PATHWAY with those from other models. These results identified strengths and weaknesses in the model and aided in establishing the confidence associated with model prediction, which is a critical component risk assessment and dose reconstruction. For fallout from the Nevada Test Site, by far, the largest internal doses were received by the thyroid. However, the predicted number of fatal cancers from ingestion dose was generally much smaller than the number predicted from external dose. The number of fatal cancers predicted from ingestion dose was also orders of magnitude below the normal projected cancer rate. Several lessons were learned during the study that are relevant to other dose reconstruction efforts

  19. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  20. Estimates of effective equivalent dose commitments for Slovene population following the Chernobyl accident

    International Nuclear Information System (INIS)

    Kanduc, M.; Jovanowic, O.; Kuhar, B.

    2004-01-01

    This paper shows the estimates of effective equivalent dose commitments for the two groups of Slovene population, 5 years old children and adults. Doses were calculated on the basis of the ICRP 30 methodology, first from the measurements of the concentrations of the radionuclides in air, water and food samples and then compared with the results of the measurements of radionuclides in composite samples of the prepared food, taken in the kindergarten nearby. Results show that there is certain degree of conservatism hidden in the calculation of the doses on the basis of measurements of the activity concentration in the elements of the biosphere and is estimated to be roughly 50%. (author)

  1. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  2. Dose rate estimation of the Tohoku hynobiid salamander, Hynobius lichenatus, in Fukushima.

    Science.gov (United States)

    Fuma, Shoichi; Ihara, Sadao; Kawaguchi, Isao; Ishikawa, Takahiro; Watanabe, Yoshito; Kubota, Yoshihisa; Sato, Youji; Takahashi, Hiroyuki; Aono, Tatsuo; Ishii, Nobuyoshi; Soeda, Haruhi; Matsui, Kumi; Une, Yumi; Minamiya, Yukio; Yoshida, Satoshi

    2015-05-01

    The radiological risks to the Tohoku hynobiid salamanders (class Amphibia), Hynobius lichenatus due to the Fukushima Dai-ichi Nuclear Power Plant accident were assessed in Fukushima Prefecture, including evacuation areas. Aquatic egg clutches (n = 1 for each sampling date and site; n = 4 in total), overwintering larvae (n = 1-5 for each sampling date and site; n = 17 in total), and terrestrial juveniles or adults (n = 1 or 3 for each sampling date and site; n = 12 in total) of H. lichenatus were collected from the end of April 2011 to April 2013. Environmental media such as litter (n = 1-5 for each sampling date and site; n = 30 in total), soil (n = 1-8 for each sampling date and site; n = 31 in total), water (n = 1 for each sampling date and site; n = 17 in total), and sediment (n = 1 for each sampling date and site; n = 17 in total) were also collected. Activity concentrations of (134)Cs + (137)Cs were 1.9-2800, 0.13-320, and 0.51-220 kBq (dry kg) (-1) in the litter, soil, and sediment samples, respectively, and were 0.31-220 and <0.29-40 kBq (wet kg)(-1) in the adult and larval salamanders, respectively. External and internal absorbed dose rates to H. lichenatus were calculated from these activity concentration data, using the ERICA Assessment Tool methodology. External dose rates were also measured in situ with glass dosimeters. There was agreement within a factor of 2 between the calculated and measured external dose rates. In the most severely contaminated habitat of this salamander, a northern part of Abukuma Mountains, the highest total dose rates were estimated to be 50 and 15 μGy h(-1) for the adults and overwintering larvae, respectively. Growth and survival of H. lichenatus was not affected at a dose rate of up to 490 μGy h(-1) in the previous laboratory chronic gamma-irradiation experiment, and thus growth and survival of this salamander would not be affected, even in the most severely contaminated habitat in Fukushima Prefecture. However, further

  3. A dynamic model to estimate the dose rate of marine biota (K-BIOTADYN- M) and its application to the Fukushima accident

    Energy Technology Data Exchange (ETDEWEB)

    Keum, Dong-Kwon; Jun, In; Kim, Byeong-Ho; Lim, Kwang-Muk; Choi, Yong-ho [Nuclear Environmental Safety Research Division, Korea Atomic Energy Research Institute, 989-111 Daedeodaero, Yuseong, Daejeon, 305-353 (Korea, Republic of)

    2014-07-01

    This paper describes a dynamic compartment model, K-BIOTA-DYN-M, to assess the activity concentration and dose rate of marine biota when the seawater activity varies with time, which is likely for the early phase after an accident. The model consists of seven compartments, phytoplankton, zooplankton, prey fish, benthic fish, crustacean, mollusk, and macro-algae. The phytoplankton compartment is assumed to be instantaneously in equilibrium with the seawater owing to the huge mass of the plankton in sea, and thus the activity of the phytoplankton is estimated using the equilibrium concentration ratio. The other compartments intake the radioactivity from both water and food, and lose the radioactivity by the biological elimination and radioactivity decay. Given the seawater activity, a set of ordinary differential equations representing the activity balance for biota is solved to obtain the time-variant activity concentration of biota, which is subsequently used to calculate the internal dose rate. The key parameters include the water intake rate, the daily feeding rate, the assimilation efficiency of radionuclides from food, the occupancy factor, and so on. The model has been applied to predict the activity concentration and dose rate of marine biota as a result the Fukushima nuclear accident on March 11, 2011. Using the seawater activities measured at three locations near the Fukushima NPPs, the time-variant activity concentration and dose rate during a few months after an accident for the seven model biota have been estimated. The preliminary results showed that the activity concentration of {sup 137}Cs in fish inhabiting the sea close to the Fukushima Daiichi NPP increased up to tenth-thousands of Bq/kg around the peak time of the seawater activity. This level is much higher than the food consumption restriction level for human protection; however, the estimated total dose rates (internal + external) for biota during the entire simulation time were all much less

  4. Reevaluation of nasal swab method for dose estimation at nuclear emergency accident

    International Nuclear Information System (INIS)

    Yamada, Yuji; Fukutsu, Kumiko; Kurihara, Osamu; Akashi, Makoto

    2008-01-01

    ICRP Publication 66 human respiratory tract model has been used extensively over in exposure dose assessment. It is well known that respiratory deposition efficiency of inhaled aerosol and its deposition region strongly depend on the particle size. In most of exposure accidents, however, nobody knows a size of inhaled aerosol. And thus two default aerosol sizes of 5μ in AMAD for the workers and 1μ in AMAD for the public are given as being representative in the ICRP model, but both sizes are not linked directly to the maximum dose. In this study, the most hazardous size to our health effects and how to estimate an intake activity was discussed from a viewpoint of emergency medicine. In exposure accident of alpha emitter such as Pu-239, lung monitor and bioassay measurements are not the best methods for rapid estimation with high sensitivity, so that an applicability of nasal swab method has been investigated. A computer software, LUDEP, was used in the calculation of respiratory deposition. It showed that the effective dose per unit intake activity strongly depended on the inhaled aerosol size. In case of Pu-239 dioxide aerosols, it was confirmed that the maximum of dose conversion factor was observed around 0.01μ. It means that this 0.01μ is the most hazardous size at exposure accident of Pu-239. From analysis of the relationship between AI and ET l deposition, it was found that the dose conversion factor from the activity deposited in ET l region also was affected by the aerosol size. The usage of the ICRP's default size in nasal swab method might cause obvious underestimation of the intake activity. Dose estimation based on nasal swab method is possible from safety side at nuclear emergency, and the availability in quantity should be reevaluated for emergency medicine considering of chelating agent administration. (author)

  5. Estimation dose in patients of nuclear medicine. Implementation of a calculi program and methodology

    International Nuclear Information System (INIS)

    Prieto, C.; Espana, M.L.; Tomasi, L.; Lopez Franco, P.

    1998-01-01

    Our hospital is developing a nuclear medicine quality assurance program in order to comply with medical exposure Directive 97/43 EURATOM and the legal requirements established in our legislation. This program includes the quality control of equipment and, in addition, the dose estimation in patients undergoing nuclear medicine examinations. This paper is focused in the second aspect, and presents a new computer program, developed in our Department, in order to estimate the absorbed dose in different organs and the effective dose to the patients, based upon the data from the ICRP publication 53 and its addendum. (Author) 16 refs

  6. Methods for estimation of internal dose of the public from dietary

    International Nuclear Information System (INIS)

    Zhu Hongda

    1987-01-01

    Following the issue of its Publication 26, ICRP has successively published its Publication 30 to meet the great changes and improvements made in the Basic Recommendations since July of 1979. In Part 1 of Publcation 30, ICRP recommended a new method for internal dose estimation and pressented some important data. In this report, comparison is made among methods for estimation of internal dose for the public from dietary. They include: (1) the new method suggested by ICRP; (2) the simple and convenient method using transfer factors under equilibrium conditions; (3) the methods based on the similarities of several radionuclides to their chemical analogs. It is concluded that the first method is better than the others and should be used from now on

  7. Estimate of absorbed dose received by individuals irradiated with neutrons

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Mauricio, C.L.P.

    1995-01-01

    An innovating methodology is proposed to estimate the absorbed dose received by individuals irradiated with neutrons in an accident, even in the case that the victim is not using any kind of neutron dosemeter. The method combines direct measurements of 24 Na and 32 P activated in the human body. The calculation method was developed using data taken from previously published papers and experimental measurements. Other irradiations results in different neutron spectra prove the validity of the methodology here proposed. Using a whole body counter to measure 24 Na activity, it is possible to evaluate neutron absorbed doses in the order of 140 μGy of very soft (thermal) spectra. For fast neutron fields, the lower limit for neutron dose detection increases, but the present method continues to be very useful in accidents, with higher neutron doses. (author). 5 refs., 1 fig., 4 tabs

  8. The effect of volume-of-interest misregistration on quantitative planar activity and dose estimation

    International Nuclear Information System (INIS)

    Song, N; Frey, E C; He, B

    2010-01-01

    In targeted radionuclide therapy (TRT), dose estimation is essential for treatment planning and tumor dose response studies. Dose estimates are typically based on a time series of whole-body conjugate view planar or SPECT scans of the patient acquired after administration of a planning dose. Quantifying the activity in the organs from these studies is an essential part of dose estimation. The quantitative planar (QPlanar) processing method involves accurate compensation for image degrading factors and correction for organ and background overlap via the combination of computational models of the image formation process and 3D volumes of interest defining the organs to be quantified. When the organ VOIs are accurately defined, the method intrinsically compensates for attenuation, scatter and partial volume effects, as well as overlap with other organs and the background. However, alignment between the 3D organ volume of interest (VOIs) used in QPlanar processing and the true organ projections in the planar images is required. The aim of this research was to study the effects of VOI misregistration on the accuracy and precision of organ activity estimates obtained using the QPlanar method. In this work, we modeled the degree of residual misregistration that would be expected after an automated registration procedure by randomly misaligning 3D SPECT/CT images, from which the VOI information was derived, and planar images. Mutual information-based image registration was used to align the realistic simulated 3D SPECT images with the 2D planar images. The residual image misregistration was used to simulate realistic levels of misregistration and allow investigation of the effects of misregistration on the accuracy and precision of the QPlanar method. We observed that accurate registration is especially important for small organs or ones with low activity concentrations compared to neighboring organs. In addition, residual misregistration gave rise to a loss of precision

  9. Retrospective methods to estimate radiation dose at the site of breast cancer development after Hodgkin lymphoma radiotherapy

    Directory of Open Access Journals (Sweden)

    Nicola S. Russell

    2017-12-01

    Full Text Available Background: An increased risk of breast cancer following radiotherapy for Hodgkin lymphoma (HL has now been robustly established. In order to estimate the dose–response relationship more accurately, and to aid clinical decision making, a retrospective estimation of the radiation dose delivered to the site of the subsequent breast cancer is required. Methods: For 174 Dutch and 170 UK female patients with breast cancer following HL treatment, the 3-dimensional position of the breast cancer in the affected breast was determined and transferred onto a CT-based anthropomorphic phantom. Using a radiotherapy treatment planning system the dose distribution on the CT-based phantom was calculated for the 46 different radiation treatment field set-ups used in the study population. The estimated dose at the centre of the breast cancer, and a margin to reflect dose uncertainty were determined on the basis of the location of the tumour and the isodose lines from the treatment planning. We assessed inter-observer variation and for 47 patients we compared the results with a previously applied dosimetry method. Results: The estimated median point dose at the centre of the breast cancer location was 29.75 Gy (IQR 5.8–37.2, or about 75% of the prescribed radiotherapy dose. The median dose uncertainty range was 5.97 Gy. We observed an excellent inter-observer variation (ICC 0.89 (95% CI: 0.74–0.95. The absolute agreement intra-class correlation coefficient (ICC for inter-method variation was 0.59 (95% CI: 0.37–0.75, indicating (nearly good agreement. There were no systematic differences in the dose estimates between observers or methods. Conclusion: Estimates of the dose at the point of a subsequent breast cancer show good correlation between methods, but the retrospective nature of the estimates means that there is always some uncertainty to be accounted for. Keywords: Retrospective dosimetry, Hodgkin lymphoma, Breast carcinogenesis

  10. Absorbed dose to mice in prolonged irradiation by low-dose rate ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, Akihiro [National Inst. of Radiological Sciences, Chiba (Japan); Saitou, Mikio; Kudo, Iwao [and others

    2000-07-01

    In this paper, the dose absorbed by mice was evaluated as a preliminary study of the late effects of prolonged continuous irradiation of mice with low-dose rate ionizing radiation. Eight-week-old male and female SPF C3H/HeN mice in three irradiation rooms were exposed to irradiation at 8000, 400, and 20 mGy, respectively, using a {sup 137}Cs {gamma}-source. Nine racks were arranged in a circle approximately 2.5 m from the source in each room, and 10 cages were arranged on the 4 shelves of each rack. Dose distributions, such as in air at the source level, in the three rooms were estimated by using ionization chambers, and the absorbed dose distributions in the room and relative dose distributions in the cages in relation to the distance of the cage center were examined. The mean abdomen doses of the mice measured by TLD were compared with the absorbed doses in the cages. The absorbed dose distributions showed not only inverse-inverse-square-law behavior with distance from the source, but geometric symmetry in every room. The inherent scattering and absorption in each room are responsible for such behavior and asymmetry. Comparison of relative dose distributions revealed cage positions that are not suitable for experiments with high precision doses, but all positions can be used for prolonged continuous irradiation experiments if the position of the cages is rotated regularly. The mean abdomen doses of the mice were similar in each cage. The mean abdomen doses of the mice and the absorbed doses in a cage were almost the same in all cages. Except for errors concerning the positions of the racks and cages, the uncertainties in the exposure doses were estimated to be about {+-}12% for 8000 mGy group, 17% for 400 mGy group, and 35% for 20 mGy group. (K.H.)

  11. FY 1991 project plan for the Hanford Environmental Dose Reconstruction Project, Phase 2

    International Nuclear Information System (INIS)

    1991-02-01

    Phase 1 of the Hanford Environmental Dose Reconstruction Project was designed to develop and demonstrate a method for estimating radiation doses people may have received from Hanford Site operations since 1944. The method researchers developed relied on a variety of measured and reconstructed data as input to a modular computer model that generates dose estimates and their uncertainties. As part of Phase 1, researchers used the reconstructed data and computer model to calculate preliminary dose estimates for populations in a limited geographical area and time period. Phase 2, now under way, is designed to evaluate the Phase 1 data and model and improve them to calculate more accurate and precise dose estimates. Phase 2 will also be used to obtain preliminary estimates of two categories of doses: for Native American tribes and for individuals included in the pilot phase of the Hanford Thyroid Disease Study (HTDS). TSP Directive 90-1 required HEDR staff to develop Phase 2 task plans for TSP approval. Draft task plans for Phase 2 were submitted to the TSP at the October 11--12, 1990 public meeting, and, after discussions of each activity and associated budget needs, the TSP directed HEDR staff to proceed with a slate of specific project activities for FY 1991 of Phase 2. This project plan contains detailed information about those activities. Phase 2 is expected to last 15--18 months. In mid-FY 1991, project activities and budget will be reevaluated to determine whether technical needs or priorities have changed. Separate from, but related to, this project plan, will be an integrated plan for the remainder of the project. HEDR staff will work with the TSP to map out a strategy that clearly describes ''end products'' for the project and the work necessary to complete them. This level of planning will provide a framework within which project decisions in Phases 2, 3, and 4 can be made

  12. A demonstration of dose modeling at Yucca Mountain

    International Nuclear Information System (INIS)

    Miley, T.B.; Eslinger, P.W.

    1992-11-01

    The U. S. Environmental Protection Agency is currently revising the regulatory guidance for high-level nuclear waste disposal. In its draft form, the guidelines contain dose limits. Since this is likely to be the case in the final regulations, it is essential that the US Department of Energy be prepared to calculate site-specific doses for any potential repository location. This year, Pacific Northwest Laboratory (PNL) has made a first attempt to estimate doses for the potential geologic repository at Yucca Mountain, Nevada as part of a preliminary total-systems performance assessment. A set of transport scenarios was defined to assess the cumulative release of radionuclides over 10,000 years under undisturbed and disturbed conditions at Yucca Mountain. Dose estimates were provided for several of the transport scenarios modeled. The exposure scenarios used to estimate dose in this total-systems exercise should not, however, be considered a definitive set of scenarios for determining the risk of the potential repository. Exposure scenarios were defined for waterborne and surface contamination that result from both undisturbed and disturbed performance of the potential repository. The exposure scenarios used for this analysis were designed for the Hanford Site in Washington. The undisturbed performance scenarios for which exposures were modeled are gas-phase release of 14 C to the surface and natural breakdown of the waste containers with waterborne release. The disturbed performance scenario for which doses were estimated is exploratory drilling. Both surface and waterborne contamination were considered for the drilling intrusion scenario

  13. Biological dosimetry - a Bayesian approach in the presentation of the uncertainty of the estimated dose in cases of exposure to low dose radiation

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Zaretzky, A.

    2010-01-01

    Biodosimetry laboratory experience has shown that there are limitations in the existing statistical methodology. Statistical difficulties generally occur due to the low number of aberrations leading to large uncertainties for dose estimation. Some problems derived from limitations of the classical statistical methodology, which requires that chromosome aberration yields be considered as something fixed and consequently provides a deterministic dose estimation and associated confidence limits. On the other hand, recipients of biological dosimetry reports, including medical doctors, regulators and the patients themselves may have a limited comprehension of statistics and of informed reports. Thus, the objective of the present paper is to use a Bayesian approach to present the uncertainty on the estimated dose to which a person could be exposed, in the case of low dose (occupational doses) radiation exposure. Such methodology will allow the biodosimetrists to adopt a probabilistic approach for the cytogenetic data analysis. At present, classical statistics allows to produce a confidence interval to report such dose, with a lower limit that could not detach from zero. In this situation it becomes difficult to make decisions as they could impact on the labor activities of the worker if an exposure exceeding the occupational dose limits is inferred. The proposed Bayesian approach is applied to occupational exposure scenario to contribute to take the appropriate radiation protection measures. (authors) [es

  14. Estimation of population doses from chest mass screening, 1975

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Maruyama, Takashi

    1977-01-01

    The population doses in mass photofluorography of the chest were estimated on the basis of nation-wide radiological survey. A total frequency of photofluorographic examinations for the chest mass survey was 18.3 million for males and 15.0 million for females, with a total of 33.3 million. Mass surveys of the chest during the school age are carried out only at the time of admission into the primary school (5 or 6 years old) and at the second class of the junior high school (13 or 14 years old). The gonad doses were determined with an ionization chamber placed at the position of gonad in tissue-equivalent phantoms. The active bone marrow was subdivided into 72 elements. The dose contribution to the marrow arising from the particular exposure conditions was calculated at each site within the elements, using the depth-dose curves experimentally determined and the proportion of the total active bone marrow present at that site. The resultant genetically significant dose for males and females was 0.07 and 0.025 mrad per person per year, respectively, with a total of 0.032 mrad per person per year. The per Caput mean marrow dose for male and female was 5.5 and 4.2 mrad per year, respectively, with a total of 9.7 mrad per year. The leukemia significant dose was calculated from the per Caput mean marrow dose by adopting weighting factor, that is leukemia significant factor. The resultant leukemia significant factor for male and female was 5.2 and 4.1 mrad per person per year, respectively. (auth.)

  15. Exposure dose estimation of nursing personnel and visitors following "1"2"5I brachytherapy

    International Nuclear Information System (INIS)

    Nakazato, Kazuhisa; Kikuchi, Hirosumi; Hotta, Harumi; Nishizawa, Kunihide

    2007-01-01

    An automated access management system to the controlled sickrooms for "1"2"5I brachytherapy was developed. The system consists of access control and video surveillance units. The patients implanted "1"2"5I seeds were isolated for about 20 h after surgery in the controlled sickrooms. The maximum doses and dose rates of the nurses and visitors were estimated by using the legal upper limit activity of 1,300 MBq, the measured longest staying time, and the shortest distance between the patients and individuals. Video analysis revealed activities of the nurses, patients, and visitors in the controlled sickroom, and relationships between the access frequency and staying time. The nurses' measured doses ranged from 1 to 3 μSv, and averaged 1.6 μSv. The nurses' maximum dose and dose rate were 16 μSv and 5.6 nSv·h"-"1·MBq"-"1. The visitors' maximum dose and dose rate were 6 μSv and 2.6 nSv·h"-"1·MBq"-"1. The nurses and visitors' exposure doses per patient were estimated to be negligible compared with the annual limit of the public. (author)

  16. Radiation doses to patients in computed tomography including a ready reckoner for dose estimation

    International Nuclear Information System (INIS)

    Szendroe, G.; Axelsson, B.; Leitz, W.

    1995-11-01

    The radiation burden from CT-examinations is still growing in most countries and has reached a considerable part of the total from medical diagnostic x-ray procedures. Efforts for avoiding excess radiation doses are therefore especially well motivated within this field. A survey of CT-examination techniques practised in Sweden showed that standard settings for the exposure variables are used for the vast majority of examinations. Virtually no adjustments to the patient's differences in anatomy have been performed - even for infants and children on average the same settings have been used. The adjustment of the exposure variables to the individual anatomy offers a large potential of dose savings. Amongst the imaging parameters, a change of the radiation dose will primarily influence the noise. As a starting point it is assumed that, irrespective of the patient's anatomy, the same level of noise can be accepted for a certain diagnostic task. To a large extent the noise level is determined by the number of photons that are registered in the detector. Hence, for different patient size and anatomy, the exposure should be adjusted so that the same transmitted photon fluence is achieved. An appendix with a ready reckoner for dose estimation for CT-scanners used in Sweden is attached. 7 refs, 5 figs, 8 tabs

  17. Supplemental computational phantoms to estimate out-of-field absorbed dose in photon radiotherapy

    Science.gov (United States)

    Gallagher, Kyle J.; Tannous, Jaad; Nabha, Racile; Feghali, Joelle Ann; Ayoub, Zeina; Jalbout, Wassim; Youssef, Bassem; Taddei, Phillip J.

    2018-01-01

    The purpose of this study was to develop a straightforward method of supplementing patient anatomy and estimating out-of-field absorbed dose for a cohort of pediatric radiotherapy patients with limited recorded anatomy. A cohort of nine children, aged 2-14 years, who received 3D conformal radiotherapy for low-grade localized brain tumors (LBTs), were randomly selected for this study. The extent of these patients’ computed tomography simulation image sets were cranial only. To approximate their missing anatomy, we supplemented the LBT patients’ image sets with computed tomography images of patients in a previous study with larger extents of matched sex, height, and mass and for whom contours of organs at risk for radiogenic cancer had already been delineated. Rigid fusion was performed between the LBT patients’ data and that of the supplemental computational phantoms using commercial software and in-house codes. In-field dose was calculated with a clinically commissioned treatment planning system, and out-of-field dose was estimated with a previously developed analytical model that was re-fit with parameters based on new measurements for intracranial radiotherapy. Mean doses greater than 1 Gy were found in the red bone marrow, remainder, thyroid, and skin of the patients in this study. Mean organ doses between 150 mGy and 1 Gy were observed in the breast tissue of the girls and lungs of all patients. Distant organs, i.e. prostate, bladder, uterus, and colon, received mean organ doses less than 150 mGy. The mean organ doses of the younger, smaller LBT patients (0-4 years old) were a factor of 2.4 greater than those of the older, larger patients (8-12 years old). Our findings demonstrated the feasibility of a straightforward method of applying supplemental computational phantoms and dose-calculation models to estimate absorbed dose for a set of children of various ages who received radiotherapy and for whom anatomies were largely missing in their original

  18. Average fetal depth in utero: data for estimation of fetal absorbed radiation dose

    International Nuclear Information System (INIS)

    Ragozzino, M.W.; Breckle, R.; Hill, L.M.; Gray, J.E.

    1986-01-01

    To estimate fetal absorbed dose from radiographic examinations, the depth from the anterior maternal surface to the midline of the fetal skull and abdomen was measured by ultrasound in 97 pregnant women. The relationships between fetal depth, fetal presentation, and maternal parameters of height, weight, anteroposterior (AP) thickness, gestational age, placental location, and bladder volume were analyzed. Maternal AP thickness (MAP) can be estimated from gestational age, maternal height, and maternal weight. Fetal midskull and abdominal depths were nearly equal. Fetal depth normalized to MAP was independent or nearly independent of maternal parameters and fetal presentation. These data enable a reasonable estimation of absorbed dose to fetal brain, abdomen, and whole body

  19. ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    Science.gov (United States)

    Jeong, Jongtae; Ko, Nak Yul; Cho, Dong-Keun; Baik, Min Hoon; Yoon, Ki-Hoon

    2018-03-16

    Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculated the exposure dose and mass of NORM waste to be disposed in landfill site by considering the activity concentration level and exposure dose. In 2012, the Korean government promulgated an act on the safety control of NORM around living environments to protect human health and the environment. For the successful implementation of this act, we suggest a reference design for a landfill for the disposal of NORM waste. Based on this reference landfill, we estimate the maximum exposure doses and the relative impact of each pathway to exposure dose for three scenarios: a reference scenario, an ingestion pathway exclusion scenario, and a low leach rate scenario. Also, we estimate the possible quantity of NORM waste disposal into a landfill as a function of the activity concentration level of U series, Th series and 40K and two kinds of exposure dose levels, 1 and 0.3 mSv/y. The results of this study can be used to support the establishment of technical bases of the management strategy for the safe disposal of NORM waste.

  20. Preliminary design of offshore wind turbine support structures : The importance of proper mode shape estimation

    NARCIS (Netherlands)

    Van der Male, P.

    2013-01-01

    Offshore wind turbines are highly exposed to timevarying loads. For support structures, estimation of the fatigue damage during the lifetime of the structure is an essential design aspect. This already applies for the preliminary design stage. In determining the dynamic amplification in the

  1. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  2. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  3. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    Science.gov (United States)

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  4. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  5. Estimation of individual doses from external exposures and dose-group classification of cohort members in high background radiation area in Yangjiang, China

    International Nuclear Information System (INIS)

    Yuan Yongling; Shen Hong; Sun Quanfu; Wei Luxin

    1999-01-01

    Objective: In order to estimate annual effective doses from external exposures in the high background radiation area (HBRA) and in the control area (CA) , the authors measured absorbed dose rates in air from terrestrial gamma radiation with different dosimeters. A dose group classification was an important step for analyzing the dose effects relationship among the cohort members in the investigated areas. The authors used the hamlet specific average annual effective doses of all the 526 hamlets in the investigated areas. A classification of four dose groups was made for the cohort members (high, moderate, low and control) . Methods: For the purpose of studying the dose effect relationships among the cohort members in HBRA and CA, it would be ideal that each subject has his own record of individual accumulated doses received before the evaluation. However, rt is difficult to realize it in practice (each of 106517 persons should wear TLD for a long time) . Thus the authors planned two sets of measurements. Firstly, to measure the environmental dose rates (outdoor, indoor, over the bed) in every hamlet of the investigated area (526 hamlets) , considering the occupancy factors for males and females of different age groups to convert to the annual effective dose from the data of dose rates. Secondly, to measure the individual cumulative dose with TLD for part of the subjects in the investigated areas. Results: Based on the two sets of measurements, the estimates of average annual effective doses in HBRA were 211.86 and 206.75 x 10 -5 Sv/a, respectively, 68.60 and 67.11 x 10 -5 Sv/a, respectively(gamma radiation only) . The intercomparison between these two sets of measurement showed that they were in good correlation. Thus the authors are able to yield the equations of linear regression: Y = 0.9937 + 6.0444, r = 0.9949. Conclusions: The authors took the value obtained from direct measurement as 'standard' , and 15 % for uncertainty of measurement. Since the estimates of

  6. Natural radioactivity and estimated dose in Brazilian tobacco products

    International Nuclear Information System (INIS)

    Oliveira, Aline S.G.R. de; Damatto, Sandra R.

    2017-01-01

    Tobacco products contain significant concentrations of natural radionuclides from 238 U and 232 Th series. The consumption of these products increases the internal dose of radiation due to the inhalation of the natural radionuclides. Studies from literature emphasize that tobacco products have measurable concentrations of 210 Po and 210 Pb, and may contribute significantly to the increase of internal radiation dose and a large number of lung cancer in smokers. The objectives of this work were to determine the concentrations (Bq/kg) of the radionuclides 226 Ra, 228 Ra, 210 Pb and 210 Po and calculate the internal doses of radiation due to the consumption of these products. In the present work 71 samples were analyzed, consisting of cigars, unflavored and flavored cigarettes, straw cigarettes, cigars and roll smoke. The samples were purchased in Brazilian popular commercial establishments. The analytical techniques employed were the gross alpha and beta measurement after radiochemical separation for the radionuclides 226 Ra, 228 Ra, 210 Pb and alpha spectrometry for 210 Po. The internal radiation doses were calculated with the activity concentrations determined and using the ICRP Publication 119 dose coefficients. An annual consumption of 3,650 kg of tobacco products was considered. The inhalation rates of each radionuclide followed the rates of the current literature. The estimated mean annual dose varied from 76 to 263μSv/y for the tobacco product studied in this work. (author)

  7. Natural radioactivity and estimated dose in Brazilian tobacco products

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Aline S.G.R. de; Damatto, Sandra R., E-mail: aline.oliveira@ipen.br, E-mail: damatto@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Tobacco products contain significant concentrations of natural radionuclides from {sup 238}U and {sup 232}Th series. The consumption of these products increases the internal dose of radiation due to the inhalation of the natural radionuclides. Studies from literature emphasize that tobacco products have measurable concentrations of {sup 210}Po and {sup 210}Pb, and may contribute significantly to the increase of internal radiation dose and a large number of lung cancer in smokers. The objectives of this work were to determine the concentrations (Bq/kg) of the radionuclides {sup 226}Ra, {sup 228}Ra, {sup 210}Pb and {sup 210}Po and calculate the internal doses of radiation due to the consumption of these products. In the present work 71 samples were analyzed, consisting of cigars, unflavored and flavored cigarettes, straw cigarettes, cigars and roll smoke. The samples were purchased in Brazilian popular commercial establishments. The analytical techniques employed were the gross alpha and beta measurement after radiochemical separation for the radionuclides {sup 226}Ra, {sup 228}Ra, {sup 210}Pb and alpha spectrometry for {sup 210}Po. The internal radiation doses were calculated with the activity concentrations determined and using the ICRP Publication 119 dose coefficients. An annual consumption of 3,650 kg of tobacco products was considered. The inhalation rates of each radionuclide followed the rates of the current literature. The estimated mean annual dose varied from 76 to 263μSv/y for the tobacco product studied in this work. (author)

  8. Comparison of doses, before and after remedial action

    International Nuclear Information System (INIS)

    Wallo, A. III

    1988-01-01

    The Division of Facility and Site Decommissioning Projects at DOE-Headquarters is evaluating potential doses from vicinity properties before and after remedial action at several sites using the RESRAD computer code. A preliminary review was completed for nineteen Colonie vicinity properties. This review indicated potential doses before remedial action at these sites ranged from about 43 to 2 mrem/year and after remediation between 5 and 0 mrem/year. These estimates indicate the conservatism in the DOE-derived soil decontamination remedial action. Following remedial action, the potential doses are on the order of those being considered to be below regulatory concern by EPA and NRC. The estimates made for these sites are still conservative due to the method used to determine the source term. More realistic assessments of source terms are anticipate dot significantly affect the after-remedial-action doses, possibly lowering them all to below 1 mrem/year. This evaluation is being refined with more realistic estimates of the source term, for all of the Colonie vicinity properties. Once the Colonie vicinity properties are completed, at least three other sites will be evaluated. It is hoped that this information will provide added confidence in the remedial action guidelines and more general acceptance of the guidelines by the EPA and others

  9. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT.

    Science.gov (United States)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W

    2012-04-01

    To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Estimation of collective effective dose equivalent from environmental radiation and radioactive materials in Japan. A preliminary study

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Noda, Yutaka; Takeshita, Mitsue; Iwai, Kazuo.

    1994-01-01

    The peaceful uses of nuclear power and radiations have been developed into a stage of practical applications for human life. Radiation causes harmful effects to human beings, although human beings receives a number of invaluable benefits from the nuclear energy and the uses of radiation. In order to examine the optimization of radiation protection in these practices, collective effective dose equivalent from environmental exposures due to natural and artificial radiations have been preliminarily evaluated using most recent data. The resultant collective doses were compared with those from medical and occupational exposures. It is noted that, in Japan, the collective effective dose from environmental radiation sources can be approximately same to that from medical exposure. (author)

  11. Dose estimation for paediatric cranial computed tomography

    International Nuclear Information System (INIS)

    Curci Daros, K.A.; Bitelli Medeiros, R.; Curci Daros, K.A.; Oliveira Echeimberg, J. de

    2006-01-01

    6.0 -1 +47(10)x10 -3 p cm -1 and ρ((p) 0,87(7)-0,007(7)p cm -1 respectively. As the exam protocol used 120 kV, 300 mAs, and slice thickness/spacing of 3/5 mm and 5/7 mm for the posterior fossa and supratentorial regions respectively, total calculated dose was 11.3(3.3) mGy. Eye region calculated dose was 0.4(0.1) mGy. Conclusion: Thermoluminescent dosimetry can be used in determining integral patient absorbed dose distribution in the three cranial regions under different X-ray exposure conditions. The proposed function permitted dose estimation in cranial paediatric exams independent of mAs because maximum T.L readings were determined in the supratentorial region, maintaining the above-mentioned operational and geometrical conditions. (authors)

  12. The Dose Estimation Formula Of Photon Radiation To Film Badge Of Kodak Type 2

    International Nuclear Information System (INIS)

    Rohmah, Nur

    2000-01-01

    Study to determine the formula of dose estimation for photon radiation to film badge of Kodak type 2 has been carried out. The irradiation was done by irradiated film badge of Kodak type 2 using photon sources of X-rays machine, 137 Cs and 60 Co. By determining the apparent dose and also the sensitivity values each filters of the calibration curve and the weighting factors of energy dependence curve, the formula of the dose estimation for film badge of Kodak type 2 could be obtained, i.e. H 1cm 2.066761E-02N ADPI-2 + 1.953342N ADAI - 8.946254N ADCu + 24.80611N ADSn/pb

  13. Use of prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Priyada, P.; Sarkar, P.K., E-mail: pradip.sarkar@manipal.edu

    2015-06-11

    The possibility of using measured prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent is explored theoretically. Monte Carlo simulations have been carried out using the FLUKA code to calculate the response of a high density polyethylene cylinder to emit prompt gammas from interaction of neutrons with the nuclei of hydrogen and carbon present in polyethylene. The neutron energy dependent responses of hydrogen and carbon nuclei are combined appropriately to match the energy dependent neutron fluence to ambient dose equivalent conversion coefficients. The proposed method is tested initially with simulated spectra and then validated using experimental measurements with an Am–Be neutron source. Experimental measurements and theoretical simulations have established the feasibility of estimating neutron ambient dose equivalent using measured neutron induced prompt gammas emitted from polyethylene with an overestimation of neutron dose at very low energies. - Highlights: • A new method for estimating H{sup ⁎}(10) using prompt gamma emissions from HDPE. • Linear combination of 2.2 MeV and 4.4 MeV gamma intensities approximates DCC (ICRP). • Feasibility of the method was established theoretically and experimentally. • The response of the present technique is very similar to that of the rem meters.

  14. AIRDOS-II computer code for estimating radiation dose to man from airborne radionuclides in areas surrouding nuclear facilities

    International Nuclear Information System (INIS)

    Moore, R.E.

    1977-04-01

    The AIRDOS-II computer code estimates individual and population doses resulting from the simultaneous atmospheric release of as many as 36 radionuclides from a nuclear facility. This report describes the meteorological and environmental models used is the code, their computer implementation, and the applicability of the code to assessments of radiological impact. Atmospheric dispersion and surface deposition of released radionuclides are estimated as a function of direction and distance from a nuclear power plant or fuel-cycle facility, and doses to man through inhalation, air immersion, exposure to contaminated ground, food ingestion, and water immersion are estimated in the surrounding area. Annual doses are estimated for total body, GI tract, bone, thyroid, lungs, muscle, kidneys, liver, spleen, testes, and ovaries. Either the annual population doses (man-rems/year) or the highest annual individual doses in the assessment area (rems/year), whichever are applicable, are summarized in output tables in several ways--by nuclides, modes of exposure, and organs. The location of the highest individual doses for each reference organ estimated for the area is specified in the output data

  15. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology

    International Nuclear Information System (INIS)

    Vano, E.; Sanchez, R.M.; Fernandez, J.M.

    2015-01-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 μSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm 2 , respectively. The median ratios for dosemeters worn over the apron by operators ( protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 μSv Gy -1 cm -2 , respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y -1 and per operator were necessary to reach the new lens dose limit for the three interventional specialties. (authors)

  16. Use of virtual reality to estimate radiation dose rates in nuclear plants

    International Nuclear Information System (INIS)

    Augusto, Silas C.; Mol, Antonio C.A.; Jorge, Carlos A.F.; Couto, Pedro M.

    2007-01-01

    Operators in nuclear plants receive radiation doses during several different operation procedures. A training program capable of simulating these operation scenarios will be useful in several ways, helping the planning of operational procedures so as to reduce the doses received by workers, and to minimize operations' times. It can provide safe virtual operation training, visualization of radiation dose rates, and estimation of doses received by workers. Thus, a virtual reality application, a free game engine, has been adapted to achieve the goals of this project. Simulation results for Argonauta research reactor of Instituto de Engenharia Nuclear are shown in this paper. A database of dose rate measurements, previously performed by the radiological protection service, has been used to display the dose rate distribution in the region of interest. The application enables the user to walk in the virtual scenario, displaying at all times the dose accumulated by the avatar. (author)

  17. Estimation of skyshine dose from turbine building of BWR plant using Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Yuji, Nemoto; Toshihisa, Tsukiyama; Shigeki, Nemezawa [Hitachi. Ltd., Saiwai-cho, Hitachi (Japan); Tadashi, Yamasaki; Hidetsugu, Okada [Chubu Electric Power Company, Inc., Odaka-cho, Midori-ku Nagoya (Japan)

    2007-07-01

    The Monte Carlo N-Particle transport code (MCNP) was adopted to calculate the skyshine dose from the turbine building of a BWR plant for obtaining precise estimations at the site boundary. In MCNP calculation, the equipment and piping arranged on the operating floor of the turbine building were considered and modeled in detail. The inner and outer walls of the turbine building, the shielding materials around the high-pressure turbine, and the piping connected from the moisture separator to the low-pressure turbine were all considered. A three-step study was conducted to estimate the applicability of MCNP code. The first step is confirming the propriety of calculation models. The atmospheric relief diaphragms, which are installed on top of the low-pressure turbine exhaust hood, are not considered in the calculation model. There was little difference between the skyshine dose distributions that were considered when using and not using the atmospheric relief diaphragms. The calculated dose rates agreed well with the measurements taken around the turbine. The second step is estimating the dose rates on the outer roof surface of the turbine building. This calculation was made to confirm the dose distribution of gamma-rays on the turbine roof before being scattered into the air. The calculated dose rates agreed well with the measured data. The third step is making a final confirmation by comparing the calculations and measurements of skyshine dose rates around the turbine building. The source terms of the main steam system are based on the measured activity data of N-16 and C-15. As a conclusion, we were able to calculate reasonable skyshine dose rates by using MCNP code. (authors)

  18. Biological dose estimation of partial body exposures in cervix cancer patients

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Nasazzi, Nora B.; Taja, Maria R.; Roth, B.; Sardi, M.; Menendez, P.

    2000-01-01

    At present, unstable chromosome aberrations analysis in peripheral blood lymphocytes is the most sensitive method to provide a biological estimation of the dose in accidental radiation over exposures. The assessment of the dose is particularly reliable in cases of acute, uniform, whole-body exposures or after irradiation of large parts of the body. However, the scenarios of most radiation accidents result in partial-body exposures or non-uniform dose distribution, leading to a differential exposure of lymphocytes in the body. Inhomogeneity produces a yield of dicentrics, which does not conform to a Poisson distribution, but is generally over dispersed. This arises because those lymphocytes in tissues outside the radiation field will not be damaged. Most of the lymphocytes (80 %) belong to the 'redistributional pool' (lymphatic tissues and other organs) and made recirculate into peripheral blood producing a mixed irradiated and unirradiated population of lymphocytes. So-called over dispersion, with a variance greater than the mean, can be taken as an indication of non-uniform exposure. The main factors operating in vivo partial-body irradiation may be the location and size of the irradiation field and, at high doses, various cellular reactions such as reduced blast transformation, mitotic delay or interphase death may contribute. For partial-body exposures, mathematical-statistical analysis of chromosome aberration data can be performed to derive a dose estimate for the irradiated fraction of the body, been more realistic than to quote a mean equivalent uniform whole body dose. The 'Contaminated Poisson' method of Dolphin or the Qdr method of Sasaki, both based on similar principles, can achieve this. Contaminated Poisson considers the over dispersed distribution of dicentrics among all the cells scored. The observed distribution is considered to be the sum of a Poisson distribution, which represents the irradiated fraction of the body, and the remaining unexposed

  19. Estimate of the dose received in crystalline lens by pediatric interventional cardiologists

    International Nuclear Information System (INIS)

    Koren, C.; Alejo, L.; Serrada, A.

    2014-08-01

    The objective of this work is to estimate the maximum dose accumulated during one year in the crystalline lens of the pediatric interventional cardiologists that work in the Hospital Universitario La Paz. Optically Stimulated Luminescence Dosimeters (OSLDs) were used for to carry out this estimation, placed in the eyes of an anthropomorphic mannequin whose position in the room simulates the more habitual conditions of the clinical practice. Previously to the simulation, different tests to validate the used dosimetric system were realized, including those related with the stability, reproducibility and lector linearity, as well as the angular and energy dependence of the OSLDs. During the simulation the mannequin eyes were irradiated and were measured with OSLDs the rate of superficial equivalent dose in crystalline lens for the different qualities of beam habitually used, as much in fluoroscopy as in acquisition. With the obtained data during three years, corresponding to the fluoroscopy times and the acquisitions number of the interventional procedures carried out; as much therapeutic as diagnostic, and rate by measuring of obtained dose, has been considered the superficial equivalent dose and the equivalent dose at 3 mm deep accumulated in the crystalline lens of the pediatric interventional cardiologist with more work load of the Hospital, during the years 2011 and 2012. None of the obtained maximum values exceed the new dose annual limit in crystalline lens of 20 mSv, recommended by ICRP in April of 2011. (author)

  20. Dose estimation in the crystalline lens of industrial radiography personnel using Monte Carlo Method

    International Nuclear Information System (INIS)

    Lima, Alexandre Roza de

    2014-01-01

    The International Commission on Radiological Protection, ICRP, in its publication 103, reviewed recent epidemiological evidence and indicated that, for the eye lens, the absorbed dose threshold for induction of late detriment is around 0.5 Gy. On this basis, on April 21, 2011, the ICRP recommended changes to the occupational dose limit in planned exposure situations, reducing the eye lens equivalent dose limit from 150 mSv to 20 mSv per year, on average, during the period of 5 years, with exposure not to exceed 50 mSv in a single year. This paper presents the dose estimation to eye lens, H p (10), effective dose and doses to important organs in the body, received by industrial gamma radiography workers, during planned or accidental exposure situations. The computer program Visual Monte Carlo was used and two relevant scenarios were postulated. The first is a planned exposure situation scenario where the operator is directly exposed to radiation during the operation. 12 radiographic exposures per day for 250 days per year, which leads to an exposure of 36,000 seconds or 10 hours per year were considered. The simulation was carried out using the following parameters: a 192 Ir source with 1.0 TBq of activity, the source/operator distance varying from 5 m to 10 m at three different heights of 0.2 m, 1.0 m and 2.0 m. The eyes lens doses were estimated as being between 16.9 mSv/year and 66.9 mSv/year and for H p (10) the doses were between 17.7 mSv/year and 74.2 mSv/year. For the accidental exposure situation scenario, the same radionuclide and activity were used, but in this case the doses were calculated with and without a collimator. The heights above ground considered were 1.0 m, 1.5 m e 2.0 m, the source/operator distance was 40 cm and, the exposure time 74 seconds. The eyes lens doses, for 1.5 m, were 12.3 mGy and 0.28 mGy without and with a collimator, respectively. Three conclusions resulted from this work. The first was that the estimated doses show that the new

  1. Estimation of radiation dose received by the victims in a Chinese radiation accident

    International Nuclear Information System (INIS)

    Zhang, Liangan; Xu, Zhiyong; Jia, Delin; Dai, Guangfu

    2002-01-01

    In April 1999, a radiation accident happened in Henan province, China. In this accident, A 60 Co ex-service therapy radiation source was purchased by a waster purchase company, then some persons break the lead pot and taken out the stainless steel drawer with the radiation source, then sell the drawer to another small company, and the buyer reserved the drawer in his bed room until all of his family members shoot their cookies. During the event, seven persons received overdose exposure, the dose rang is about 1.0 - 6.0Gy, especially, all of the buyer family members meet with bad radiation damage. In order to assess the accident consequences and cure the patients of the bad radiation damage, it is necessary to estimate the doses of the Victims in the accident. In the dose reconstruction of the accident victims, we adopted biologic dose method, experiment-simulating method with an anthropomorphic phantom, and theory simulating method with Monte Carlo to estimate the doses of the victims. In this paper, the frame of the accident and the Monte Carlo method in our work will be described, the main dose results of the three methods mentioned above will be reported and a comparison analysis will be presented

  2. Estimation of population doses from diagnostic medical examinations in Japan, 1974. III. Per caput mean marrow dose and leukemia significant dose

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-03-01

    The mean per capita marrow dose and leukemia-significant dose from radiographic and fluoroscopic examinations in Japan have been estimated based on a 1974 nation wide survey of randomly sampled hospitals and clinics. To determine the mean marrow dose to an individual from a certain exposure of a given type of examination, the active marrow in the whole body was divided into 119 parts for an adult and 103 for a child. Dosimetric points on which the individual marrow doses were determined were set up in the center of each marrow part. The individual marrow doses at the dosimetric points in the beams of practical diagnostic x-rays were calculated on the basis of the exposure data on the patients selected in the nation wide survey, using depth dose curves experimentally determined for diagnostic x-rays. The mean individual marrow dose was averaged over the active marrow by summing, for each dosimetric point, the product of the fraction of active marrow exposed and the individual marrow dose at the dosimetric point. The leukemia significant dose was calculated by adopting a weighting factor that is, a leukemia significant factor. The factor was determined from the shape of the time-incidence curve for radiation-induced leukemia from the Hiroshima A-bomb and from the survival statistics for the average population. The resultant mean per capita marrow dose from radiographic and fluoroscopic examination was 37.0 and 70.0 mrad/person/year, respectively, with a total of 107.05 mrad/person/year. The leukemia significant dose was 32.1 mrad/person/year for radiographic examination and 61.2 mrad/person/year, with a total of 93.3. These values were compared with those of 1960 and 1969.

  3. Preliminary estimates of spatially distributed net infiltration and recharge for the Death Valley region, Nevada-California

    International Nuclear Information System (INIS)

    Hevesi, J.A.; Flint, A.L.; Flint, L.E.

    2002-01-01

    A three-dimensional ground-water flow model has been developed to evaluate the Death Valley regional flow system, which includes ground water beneath the Nevada Test Site. Estimates of spatially distributed net infiltration and recharge are needed to define upper boundary conditions. This study presents a preliminary application of a conceptual and numerical model of net infiltration. The model was developed in studies at Yucca Mountain, Nevada, which is located in the approximate center of the Death Valley ground-water flow system. The conceptual model describes the effects of precipitation, runoff, evapotranspiration, and redistribution of water in the shallow unsaturated zone on predicted rates of net infiltration; precipitation and soil depth are the two most significant variables. The conceptual model was tested using a preliminary numerical model based on energy- and water-balance calculations. Daily precipitation for 1980 through 1995, averaging 202 millimeters per year over the 39,556 square kilometers area of the ground-water flow model, was input to the numerical model to simulate net infiltration ranging from zero for a soil thickness greater than 6 meters to over 350 millimeters per year for thin soils at high elevations in the Spring Mountains overlying permeable bedrock. Estimated average net infiltration over the entire ground-water flow model domain is 7.8 millimeters per year. To evaluate the application of the net-infiltration model developed on a local scale at Yucca Mountain, to net-infiltration estimates representing the magnitude and distribution of recharge on a regional scale, the net-infiltration results were compared with recharge estimates obtained using empirical methods. Comparison of model results with previous estimates of basinwide recharge suggests that the net-infiltration estimates obtained using this model may overestimate recharge because of uncertainty in modeled precipitation, bedrock permeability, and soil properties for

  4. Radiation dose estimates due to air particulate emissions from selected phosphate industry operations

    International Nuclear Information System (INIS)

    Partridge, J.E.; Horton, T.R.; Sensintaffar, E.L.; Boysen, G.A.

    1978-06-01

    The EPA Office of Radiation Programs has conducted a series of studies to determine the radiological impact of the phosphate mining and milling industry. This report describes the efforts to estimate the radiation doses due to airborne emissions of particulates from selected phosphate milling operations in Florida. Two wet process phosphoric acid plants and one ore drying facility were selected for this study. The 1976 Annual Operations/Emissions Report, submitted by each facility to the Florida Department of Environmental Regulation, and a field survey trip by EPA personnel to each facility were used to develop data for dose calculations. The field survey trip included sampling for stack emissions and ambient air samples collected in the general vicinity of each plant. Population and individual radiation dose estimates are made based on these sources of data

  5. Estimation of absorbed dose by newborn patients subjected to chest radiographs; Estimativa de dose efetiva para radiografias do torax em pediatria neonatal

    Energy Technology Data Exchange (ETDEWEB)

    Bunick, Ana P. [Faculdades Pequeno Principe, Curitiba, PR (Brazil); Schelin, Hugo R. [Instituto de Pesquisa Pele Pequeno Principe, Curitiba, PR (Brazil); Denyak, Valeriy [Hospital Infantil Pequeno Principe, Curitiba, PR (Brazil)

    2016-07-01

    The aim of this study is to present an estimate of the effective dose received by newborn patients hospitalized in NICU and subjected to X-ray examinations of the chest in the AP projection. Initially, were followed examinations chest X-rays performed on newborn patients and subsequently, simulated in a newborn simulator object. The ESAK values obtained by TLDs were used to calculate the effective dose obtained at each examination by Caldose{sub X} software. The estimated values for the effective dose in the simulated exams in this study range from 2,3μSv the 10,7μSv. The results achieved are, generally, inferior to those reported for similar previous studies. (author)

  6. Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

    International Nuclear Information System (INIS)

    Garcia-Vazquez, Veronica; Marinetto, Eugenio; Guerra, Pedro; Valdivieso-Casique, Manlio Fabio; Calvo, Felipe Angel

    2017-01-01

    Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (''O-arm'', a cone-beam CT [CBCT] system, and ''BodyTom'', a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (''TrueBeam''). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.

  7. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Toncheva, Greta; Yoshizumi, Terry T.; Frush, Donald P. [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Medical Physics Graduate Program, Department of Physics, and Department of Biomedical Engineering, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Biomedical Engineering, University of North Carolina, Chapel Hill, North Carolina 27599 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Duke Radiation Dosimetry Laboratory, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Duke Radiation Dosimetry Laboratory, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Division of Pediatric Radiology, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2011-01-15

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller

  8. A three-dimensional dose-distribution estimation system using computerized image reconstruction

    International Nuclear Information System (INIS)

    Nishijima, Akihiko; Kidoya, Eiji; Komuro, Hiroyuki; Tanaka, Masato; Asada, Naoki.

    1990-01-01

    In radiotherapy planning, three dimensional (3-D) estimation of dose distribution has been very troublesome and time-consuming. To solve this problem, a simple and fast 3-D dose distribution image using a computer and Charged Couple Device (CCD) camera was developed. A series of X-ray films inserted in the phantom using a linear accelerator unit was exposed. The degree of film density was degitized with a CCD camera and a minicomputer (VAX 11-750). After that these results were compared with the present depth dose obtained by a JARP type dosimeter, with a dose error being less than 2%. The 3-D dose distribution image could accurately depict the density changes created by aluminum and air put into the phantom. The contrast resolution of the CCD camera seemed to be superior to the convention densitometer in the low-to-intermediate contrast range. In conclusion, our method seem to be very fast and simple for obtaining 3-D dose distribution images and is very effective when compared with the conventional method. (author)

  9. Improved estimates of external gamma dose rates in the environs of Hinkley Point Power Station

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Thompson, I.M.G.

    1988-07-01

    The dominant source of external gamma dose rates at centres of population within a few kilometres of Hinkley Point Power Station is the routine discharge of 41-Ar from the 'A' station magnox reactors. Earlier estimates of the 41-Ar radiation dose rates were based upon measured discharge rates, combined with calculations using standard plume dispersion and cloud-gamma integration models. This report presents improved dose estimates derived from environmental gamma dose rate measurements made at distances up to about 1 km from the site, thus minimising the degree of extrapolation introduced in estimating dose rates at locations up to a few kilometres from the site. In addition, results from associated chemical tracer measurements and wind tunnel simulations covering distances up to about 4 km from the station are outlined. These provide information on the spatial distribution of the 41-Ar plume during the initial stages of its dispersion, including effects due to plume buoyancy and momentum and behaviour under light wind conditions. In addition to supporting the methodology used for the 41-Ar dose calculations, this information is also of generic interest in the treatment of a range of operational and accidental releases from nuclear power station sites and will assist in the development and validation of existing environmental models. (author)

  10. Estimation of dose in dental radiology exams in critical regions; Estimativa de dose em exames de radiologia odontologica em regioes criticas

    Energy Technology Data Exchange (ETDEWEB)

    Bonzoumet, S. P.J.; Braz, D. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear. Lab. de Instrumentacao Nuclear; Barroso, R. C. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Fisica; Mauricio, Claudia; Domingues, Claudio [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Padilha, Lucas [Universidade Federal do Rio de Janeiro (HUCFF/UFRJ), RJ (Brazil). Hospital Universitario Clementino Fraga Filho

    2005-07-01

    The objective of this paper is to estimate the values of doses, which are absorbed dose to the lens and thyroid in a dental X-ray. Thermoluminescence dosimeters were used, once they provide a reading of quality and effectiveness. This study was based on dental exams conducted in patients in order to estimate the dose that disperses to the lens of the eye and for the thyroid during an intraoral exam. Data collection took place in two institutions, one governmental, which had the device SELETRONIC 70X and other particular. This study showed that there is a considerable variation between the appliances. Using the appliance DABI 1070, there was a greater absorption of radiation in the right eye (values greater than 5 mGy) and a lower dose in the thyroid, and the Seletronic 70X presented an incidence of higher dose deposited in the skin and in other points there was a balance in the values. In the appliance SELETRONIC 70X, there was again a greater absorption of radiation in the right eye and a lower setting in the thyroid. The excessive dose, besides does not favor at all for the quality of radiograph, represents a risk for the patient who absorbs unnecessary and harmful radiation to the body.

  11. Around Semipalatinsk nuclear test site: Progress of dose estimations relevant to the consequences of nuclear tests

    International Nuclear Information System (INIS)

    Stepanenko, Valeriy F.; Hoshi, Masaharu; Bailiff, Ian K.

    2006-01-01

    The paper is an analytical overview of the main results presented at the 3rd Dosimetry Workshop in Hiroshima (9-11 of March 2005), where different aspects of the dose reconstruction around the Semipalatinsk nuclear test site (SNTS) were discussed and summarized. The results of the international intercomparison of the retrospective luminescence dosimetry (RLD) method for Dolon' village (Kazakhstan) were presented at the Workshop and good concurrence between dose estimations by different laboratories from 6 countries (Japan, Russia, USA, Germany, Finland and UK) was pointed out. The accumulated dose values in brick for a common depth of 10 mm depth of 10 mm depth obtained independently by all participating laboratories were in good agreement for all four brick samples from Dolon' village, Kazakhstan, with the average value of the local gamma dose due to fallout (near the sampling locations) being about 220 mGy (background dose has been subtracted). Furthermore, using a conversion factor of about 2 to obtain the free-in-air dose, a value of local dose ∼440 mGy is obtained, which supports the results of external dose calculations for Dolon': recently published soil contamination data, archive information and new models were used for refining dose calculations and the external dose in air for Dolon village was estimated to be about 500 mGy. The results of electron spin resonance (ESR) dosimetry with tooth enamel have demonstrated the notable progress in application of ESR dosimetry to the problems of dose reconstruction around the Semipalatinsk nuclear test site. At the present moment, dose estimates by the ESR method have become more consistent with calculated values and with retrospective luminescence dosimetry data, but differences between ESR dose estimates and RLD/calculation data were noted. For example mean ESR dose for eligible tooth samples from Dolon' village was estimated to be about 140 mGy (above background dose), which is less than dose values obtained

  12. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    International Nuclear Information System (INIS)

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-01-01

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  13. 2,3,7,8-Tetrachlorodibenzo-P-Dioxin (TCDD) Dose-Response Studies: Preliminary Literature Search Results and Request for Additional Studies

    Science.gov (United States)

    EPA invited the public to comment on the preliminary list of in vivo mammalian dose-response citations for 2,3,7,8 tetrachlorodibenzo-p-dioxin (TCDD). This list was compiled as a first step in the development of EPA’s response to the National Academy of Sciences comments (NAS, 2...

  14. Modeling estimates of the effect of acid rain on background radiation dose.

    Science.gov (United States)

    Sheppard, S C; Sheppard, M I

    1988-06-01

    Acid rain causes accelerated mobilization of many materials in soils. Natural and anthropogenic radionuclides, especially 226Ra and 137Cs, are among these materials. Okamoto is apparently the only researcher to date who has attempted to quantify the effect of acid rain on the "background" radiation dose to man. He estimated an increase in dose by a factor of 1.3 following a decrease in soil pH of 1 unit. We reviewed literature that described the effects of changes in pH on mobility and plant uptake of Ra and Cs. Generally, a decrease in soil pH by 1 unit will increase mobility and plant uptake by factors of 2 to 7. Thus, Okamoto's dose estimate may be too low. We applied several simulation models to confirm Okamoto's ideas, with most emphasis on an atmospherically driven soil model that predicts water and nuclide flow through a soil profile. We modeled a typical, acid-rain sensitive soil using meteorological data from Geraldton, Ontario. The results, within the range of effects on the soil expected from acidification, showed essentially direct proportionality between the mobility of the nuclides and dose. This supports some of the assumptions invoked by Okamoto. We conclude that a decrease in pH of 1 unit may increase the mobility of Ra and Cs by a factor of 2 or more. Our models predict that this will lead to similar increases in plant uptake and radiological dose to man. Although health effects following such a small increase in dose have not been statistically demonstrated, any increase in dose is probably undesirable.

  15. Modeling estimates of the effect of acid rain on background radiation dose

    International Nuclear Information System (INIS)

    Sheppard, S.C.; Sheppard, M.I.

    1988-01-01

    Acid rain causes accelerated mobilization of many materials in soils. Natural and anthropogenic radionuclides, especially 226Ra and 137Cs, are among these materials. Okamoto is apparently the only researcher to date who has attempted to quantify the effect of acid rain on the background radiation dose to man. He estimated an increase in dose by a factor of 1.3 following a decrease in soil pH of 1 unit. We reviewed literature that described the effects of changes in pH on mobility and plant uptake of Ra and Cs. Generally, a decrease in soil pH by 1 unit will increase mobility and plant uptake by factors of 2 to 7. Thus, Okamoto's dose estimate may be too low. We applied several simulation models to confirm Okamoto's ideas, with most emphasis on an atmospherically driven soil model that predicts water and nuclide flow through a soil profile. We modeled a typical, acid-rain sensitive soil using meteorological data from Geraldton, Ontario. The results, within the range of effects on the soil expected from acidification, showed essentially direct proportionality between the mobility of the nuclides and dose. This supports some of the assumptions invoked by Okamoto. We conclude that a decrease in pH of 1 unit may increase the mobility of Ra and Cs by a factor of 2 or more. Our models predict that this will lead to similar increases in plant uptake and radiological dose to man. Although health effects following such a small increase in dose have not been statistically demonstrated, any increase in dose is probably undesirable

  16. Dose estimate of exposure to radioisotopes in molecular and cellular biology

    International Nuclear Information System (INIS)

    Onado, C.; Faretta, M.; Ubezio, P.

    1999-01-01

    A method for prospectively evaluating the annual equivalent doses and effective dose to biomedical researchers working with unsealed radioisotopes, and their classification, is presented here. Simplified formulae relate occupational data to a reasonable overestimate of the annual effective dose, and the equivalent doses to the hands and to the skin. The procedure, up to the classification of personnel and laboratories, can be made fully automatic, using a common spreadsheet on a personal computer. The method is based on occupational data, accounting for the amounts of each radioisotope used by a researcher, the time of exposure and the overall amounts employed in the laboratories where experiments are performed. The former data serve to forecast a contribution to the dose arising from a researcher's own work, the latter to a forecast of an 'environmental' contribution deriving simply from the presence in a laboratory where other people are working with radioisotopes. The estimates of the doses due to one's own radioisotope handling and to 'environment' were corrected for accidental exposure, considered as a linear function of the manipulated activity or of the time spent in the laboratories respectively, and summed up to give the effective dose. The effective dose associated with some common experiments in molecular and cellular biology is pre-evaluated by this method. (author)

  17. Tritium metabolism in newborn mice and estimation of the accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Saito, M; Ishida, M R

    1986-01-01

    Suckling mice received tritium from their mothers who were supplied with tritiated water as drinking water. After weaning, the offspring were sacrificed and the tritium concentration was determined for various organs and various molecular components including acid soluble component, lipid, RNA, DNA and protein. The accumulated dose for the period between 3 and 41 weeks after birth was calculated for various organs and the contributions of the acid insoluble components to the total dose estimated. The per cent contribution of the acid insoluble components to the total dose was organ specific and was between about 17% and 42%. The result indicates that the inhomogeneous distribution of tritium in subcellular structures needs to be taken into account. The contribution of organically bound tritium to dose is then comparable to that of tritium in the free water component.

  18. Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination.

    Science.gov (United States)

    Tsujiguchi, Takakiyo; Obara, Hideki; Ono, Shuichi; Saito, Yoko; Kashiwakura, Ikuo

    2018-04-05

    Computed tomography (CT) has recently been utilized in various medical settings, and technological advances have resulted in its widespread use. However, medical radiation exposure associated with CT scans accounts for the largest share of examinations using radiation; thus, it is important to understand the organ dose and effective dose in detail. The CT dose index and dose-length product are used to evaluate the organ dose. However, evaluations using these indicators fail to consider the age and body type of patients. In this study, we evaluated the effective dose based on the CT examination data of 753 patients examined at our hospital using the size-specific dose estimate (SSDE) method, which can calculate the exposure dose with consideration of the physique of a patient. The results showed a large correlation between the SSDE conversion factor and physique, with a larger exposure dose in patients with a small physique when a single scan is considered. Especially for children, the SSDE conversion factor was found to be 2 or more. In addition, the patient exposed to the largest dose in this study was a 10-year-old, who received 40.4 mSv (five series/examination). In the future, for estimating exposure using the SSDE method and in cohort studies, the diagnostic reference level of SSDE should be determined and a low-exposure imaging protocol should be developed to predict the risk of CT exposure and to maintain the quality of diagnosis with better radiation protection of patients.

  19. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.

    Science.gov (United States)

    Vano, E; Sanchez, R M; Fernandez, J M

    2015-07-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. The Effects of Metal on Size Specific Dose Estimation (SSDE) in CT: A Phantom Study

    Science.gov (United States)

    Alsanea, Maram M.

    Over the past number of years there has been a significant increase in the awareness of radiation dose from use of computed tomography (CT). Efforts have been made to reduce radiation dose from CT and to better quantify dose being delivered. However, unfortunately, these dose metrics such as CTDI vol are not a specific patient dose. In 2011, the size-specific dose estimation (SSDE) was introduced by AAPM TG-204 which accounts for the physical size of the patient. However, the approach presented in TG-204 ignores the importance of the attenuation differences in the body. In 2014, a newer methodology that accounted for tissue attenuation was introduced by the AAPM TG-220 based on the concept of water equivalent diameter, Dw. One of the limitation of TG-220 is that there is no estimation of the dose while highly attenuating objects such as metal is present in the body. The purpose of this research is to evaluate the accuracy of size-specific dose estimates in CT in the presence of simulated metal prostheses using a conventional PMMA CTDI phantom at different phantom diameter (body and head) and beam energy. Titanium, Cobalt- chromium and stainless steel alloys rods were used in the study. Two approaches were used as introduced by AAPM TG-204 and 220 utilizing the effective diameter and the Dw calculations. From these calculations, conversion factors have been derived that could be applied to the measured CTDIvol to convert it to specific patient dose, or size specific dose estimate, (SSDE). Radiation dose in tissue (f-factor = 0.94) was measured at various chamber positions with the presence of metal. Following, an average weighted tissue dose (AWTD) was calculated in a manner similar to the weighted CTDI (CTDIw). In general, for the 32 cm body phantom SSDE220 provided more accurate estimates of AWTD than did SSDE204. For smaller patient size, represented by the 16 cm head phantom, the SSDE204 was a more accurate estimate of AWTD that that of SSDE220. However, as the

  1. Calculational techniques for estimating population doses from radioactivity in natural gas from nuclearly stimulated wells

    International Nuclear Information System (INIS)

    Barton, C.J.; Moore, R.E.; Rohwer, P.S.; Kaye, S.V.

    1975-01-01

    Techniques for estimating radiation doses from exposure to combustion products of natural gas obtained from wells created by use of nuclear explosives were first developed in the Gasbuggy Project. These techniques were refined and extended by development of a number of computer codes in studies related to the Rulison Project, the second in the series of joint government-industry efforts to demonstrate the feasibility of increasing natural gas production from low-permeability rock formations by use of nuclear explosives. These techniques are described and dose estimates that illustrate their use are given. These dose estimation studies have been primarily theoretical, but we have tried to make our hypothetical exposure conditions correspond as closely as possible with conditions that could exist if nuclearly stimulated natural gas is used commercially. (author)

  2. Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Zanca, F., E-mail: Federica.Zanca@med.kuleuven.be [Department of Radiology, Leuven University Center of Medical Physics in Radiology, UZ Leuven, Herestraat 49, 3000 Leuven, Belgium and Imaging and Pathology Department, UZ Leuven, Herestraat 49, Box 7003 3000 Leuven (Belgium); Jacobs, A. [Department of Radiology, Leuven University Center of Medical Physics in Radiology, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium); Crijns, W. [Department of Radiotherapy, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium); De Wever, W. [Imaging and Pathology Department, UZ Leuven, Herestraat 49, Box 7003 3000 Leuven, Belgium and Department of Radiology, UZ Leuven, Herestraat 49, 3000 Leuven (Belgium)

    2014-07-15

    Purpose: To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. Methods: Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. Results: The median measured MSD was 141 mGy (range 38–410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24–262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12–4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. Conclusions: On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure.

  3. Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies

    International Nuclear Information System (INIS)

    Zanca, F.; Jacobs, A.; Crijns, W.; De Wever, W.

    2014-01-01

    Purpose: To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. Methods: Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. Results: The median measured MSD was 141 mGy (range 38–410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24–262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12–4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. Conclusions: On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure

  4. Dose estimation for paediatric cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Curci Daros, K.A.; Bitelli Medeiros, R. [Sao Paulo Univ. Federal (Brazil); Curci Daros, K.A.; Oliveira Echeimberg, J. de [Centro Univ. Sao Camilo, Sao Paulo (Brazil)

    2006-07-01

    region defined by position 6.0dose was 11.3(3.3) mGy. Eye region calculated dose was 0.4(0.1) mGy. Conclusion: Thermoluminescent dosimetry can be used in determining integral patient absorbed dose distribution in the three cranial regions under different X-ray exposure conditions. The proposed function permitted dose estimation in cranial paediatric exams independent of mAs because maximum T.L readings were determined in the supratentorial region, maintaining the above-mentioned operational and geometrical conditions. (authors)

  5. Study on method of dose estimation for the Dual-moderated neutron survey meter

    International Nuclear Information System (INIS)

    Zhou, Bo; Li, Taosheng; Xu, Yuhai; Gong, Cunkui; Yan, Qiang; Li, Lei

    2013-01-01

    In order to study neutron dose measurement in high energy radiation field, a Dual-moderated survey meter in the range from 1 keV to 300 MeV mean energies spectra has been developed. Measurement results of some survey meters depend on the neutron spectra characteristics in different neutron radiation fields, so the characteristics of the responses to various neutron spectra should be studied in order to get more reasonable dose. In this paper the responses of the survey meter were calculated under different neutron spectra data from IAEA of Technical Reports Series No. 318 and other references. Finally one dose estimation method was determined. The range of the reading per H*(10) for the method estimated is about 0.7–1.6 for the neutron mean energy range from 50 keV to 300 MeV. -- Highlights: • We studied a novel high energy neutron survey meter. • Response characteristics of the survey meter were calculated by using a series of neutron spectra. • One significant advantage of the survey meter is that it can provide mean energy of radiation field. • Dose estimate deviation can be corrected. • The range of corrected reading per H*(10) is about 0.7–1.6 for the neutron fluence mean energy range from 0.05 MeV to 300 MeV

  6. Simple method to estimate mean heart dose from Hodgkin lymphoma radiation therapy according to simulation X-rays.

    Science.gov (United States)

    van Nimwegen, Frederika A; Cutter, David J; Schaapveld, Michael; Rutten, Annemarieke; Kooijman, Karen; Krol, Augustinus D G; Janus, Cécile P M; Darby, Sarah C; van Leeuwen, Flora E; Aleman, Berthe M P

    2015-05-01

    To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case-control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor-intensive representative CT-based method. This simpler method may produce a

  7. Simple Method to Estimate Mean Heart Dose From Hodgkin Lymphoma Radiation Therapy According to Simulation X-Rays

    Energy Technology Data Exchange (ETDEWEB)

    Nimwegen, Frederika A. van [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Cutter, David J. [Clinical Trial Service Unit, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals NHS Trust, Oxford (United Kingdom); Schaapveld, Michael [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Rutten, Annemarieke [Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Kooijman, Karen [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Krol, Augustinus D.G. [Department of Radiation Oncology, Leiden University Medical Center, Leiden (Netherlands); Janus, Cécile P.M. [Department of Radiation Oncology, Erasmus MC Cancer Center, Rotterdam (Netherlands); Darby, Sarah C. [Clinical Trial Service Unit, University of Oxford, Oxford (United Kingdom); Leeuwen, Flora E. van [Department of Psychosocial Research, Epidemiology, and Biostatistics, The Netherlands Cancer Institute, Amsterdam (Netherlands); Aleman, Berthe M.P., E-mail: b.aleman@nki.nl [Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2015-05-01

    Purpose: To describe a new method to estimate the mean heart dose for Hodgkin lymphoma patients treated several decades ago, using delineation of the heart on radiation therapy simulation X-rays. Mean heart dose is an important predictor for late cardiovascular complications after Hodgkin lymphoma (HL) treatment. For patients treated before the era of computed tomography (CT)-based radiotherapy planning, retrospective estimation of radiation dose to the heart can be labor intensive. Methods and Materials: Patients for whom cardiac radiation doses had previously been estimated by reconstruction of individual treatments on representative CT data sets were selected at random from a case–control study of 5-year Hodgkin lymphoma survivors (n=289). For 42 patients, cardiac contours were outlined on each patient's simulation X-ray by 4 different raters, and the mean heart dose was estimated as the percentage of the cardiac contour within the radiation field multiplied by the prescribed mediastinal dose and divided by a correction factor obtained by comparison with individual CT-based dosimetry. Results: According to the simulation X-ray method, the medians of the mean heart doses obtained from the cardiac contours outlined by the 4 raters were 30 Gy, 30 Gy, 31 Gy, and 31 Gy, respectively, following prescribed mediastinal doses of 25-42 Gy. The absolute-agreement intraclass correlation coefficient was 0.93 (95% confidence interval 0.85-0.97), indicating excellent agreement. Mean heart dose was 30.4 Gy with the simulation X-ray method, versus 30.2 Gy with the representative CT-based dosimetry, and the between-method absolute-agreement intraclass correlation coefficient was 0.87 (95% confidence interval 0.80-0.95), indicating good agreement between the two methods. Conclusion: Estimating mean heart dose from radiation therapy simulation X-rays is reproducible and fast, takes individual anatomy into account, and yields results comparable to the labor

  8. Estimation of patient dose in abdominal CT examination in some Sudanese hospitals

    International Nuclear Information System (INIS)

    Adam, Ebthal Adam Shikhalden

    2016-04-01

    The use of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. The aim of this study was to estimate radiation doses in abdomen CT examinations of patients in two Sudanese hospitals. Details were obtained from approximately 80 CT examinations and included all age groups ( adults and pediatric). The results from the two hospitals were compared with each other as well as with the IAEA guidance level for this particular investigation. The estimation of radiation doses were carried out by calculating volume dose index (CTD1vol), dose length product (DLP), doses to some organs of interest and effective dose (E) using the software program "CT EXPO V2.1". The study showed that the mean DLP of the one hospitals ASH is 1736.7 mGy.cm which is by far much higher than that for the other hospital NMDC which stands at 185.3 mGy.cm, as well as higher than the IAEA level which is 696 mGy.cm. The study showed that the mean CTD1vol for patients in ASH is 36.2 mGy which again higher than that for the other hospital which is 3.9 mGy and higher than the IAEA level which is 10.9 mGy calculating the effective dose for patients in the two hospitals reveals that the mean effective dose of patient in one hospital (ASH) is 26.25 mSv, which is quite high compared with other hospital (NMDC), which has the mean value of 2.8 mGv and also higher than the IAEA level from this investigation which is 7.6 mSv. Regarding organ doses, the study showed that organ doses in hospital ASH are always higher than that calculated in hospital NMDC and the highest doses in both hospital were delivered to the kidneys with mean values of 50.24 mGy and 5045 mGy for the two hospitals respectively. The study showed that there is an urgent need for optimizing patient doses in such CT examinations. This can be ensured by providing training and retraining for workers and conducting quality control measurements and preventive maintenance regularly so

  9. Application of laboratory sourceless object counting for the estimation of the neutron dose

    International Nuclear Information System (INIS)

    Cheng Jie; Ning Jing; Zhang Xiaomin; Qu Decheng; Xie Xiangdong; Nan Hongjie

    2011-01-01

    Objective: To estimate the neutron dose using 24 Na energy spectrum analysis method. Methods: Genius-2000 GeomComposer software package was used to calibrate the efficiency of the detector. Results: The detection efficiency of the detector toward γ photon with an energy of 1.368 MeV was quickly found to be 4.05271×10 -3 while the error of the software was 4.0% . The estimated dose value of the neutron irradiation samples was between 1.94 Gy and 2.82 Gy, with an arithmetic mean value of 2.38 Gy. The uncertainty of the dosimetry was about 20.07% . Conclusion: The application of efficiency calibration without a radioactive source of the energy spectrum analysis of the 24 Na contained in human blood with accelerate the estimation process. (authors)

  10. 324 Building life cycle dose estimates for planned work

    Energy Technology Data Exchange (ETDEWEB)

    Landsman, S.D.; Peterson, C.A.; Thornhill, R.E.

    1995-09-01

    This report describes a tool for use by organizational management teams to plan, manage, and oversee personnel exposures within their organizations. The report encompasses personnel radiation exposures received from activities associated with the B-Cell Cleanout Project, Surveillance and Maintenance Project, the Mk-42 Project, and other minor activities. It is designed to provide verifiable Radiological Performance Reports. The primary area workers receive radiation exposure is the Radiochemical Engineering Complex airlock. Entry to the airlock is necessary for maintenance of cranes and other equipment, and to set up the rail system used to move large pieces of equipment and shipping casks into and out of the airlock. Transfers of equipment and materials from the hot cells in the complex to the airlock are required to allow dose profiles of waste containers, shuffling of waste containers to allow grouting activities to go on, and to allow maintenance of in-cell cranes. Both DOE and the Pacific Northwest Laboratory (PNL) are currently investing in state-of-the-art decontamination equipment. Challenging goals for exposure reduction were established for several broad areas of activity. Exposure estimates and goals developed from these scheduled activities will be compared against actual exposures for scheduled and unscheduled activities that contributed to exposures received by personnel throughout the year. Included in this report are life cycle exposure estimates by calendar year for the B-Cell Cleanout project, a three-year estimate of exposures associated with Surveillance and Maintenance, and known activities for Calendar Year (CY) 1995 associated with several smaller projects. These reports are intended to provide a foundation for future dose estimates, by year, requiring updating as exposure conditions change or new avenues of approach to performing work are developed.

  11. 324 Building life cycle dose estimates for planned work

    International Nuclear Information System (INIS)

    Landsman, S.D.; Peterson, C.A.; Thornhill, R.E.

    1995-09-01

    This report describes a tool for use by organizational management teams to plan, manage, and oversee personnel exposures within their organizations. The report encompasses personnel radiation exposures received from activities associated with the B-Cell Cleanout Project, Surveillance and Maintenance Project, the Mk-42 Project, and other minor activities. It is designed to provide verifiable Radiological Performance Reports. The primary area workers receive radiation exposure is the Radiochemical Engineering Complex airlock. Entry to the airlock is necessary for maintenance of cranes and other equipment, and to set up the rail system used to move large pieces of equipment and shipping casks into and out of the airlock. Transfers of equipment and materials from the hot cells in the complex to the airlock are required to allow dose profiles of waste containers, shuffling of waste containers to allow grouting activities to go on, and to allow maintenance of in-cell cranes. Both DOE and the Pacific Northwest Laboratory (PNL) are currently investing in state-of-the-art decontamination equipment. Challenging goals for exposure reduction were established for several broad areas of activity. Exposure estimates and goals developed from these scheduled activities will be compared against actual exposures for scheduled and unscheduled activities that contributed to exposures received by personnel throughout the year. Included in this report are life cycle exposure estimates by calendar year for the B-Cell Cleanout project, a three-year estimate of exposures associated with Surveillance and Maintenance, and known activities for Calendar Year (CY) 1995 associated with several smaller projects. These reports are intended to provide a foundation for future dose estimates, by year, requiring updating as exposure conditions change or new avenues of approach to performing work are developed

  12. Problems in radiation absorbed dose estimation from positron emitters

    International Nuclear Information System (INIS)

    Powell, G.F.; Harper, P.V.; Reft, C.S.; Chen, C.T.; Lathrop, K.A.

    1986-01-01

    The positron emitters commonly used in clinical imaging studies for the most part are short-lived, so that when they are distributed in the body the radiation absorbed dose is low even though most of the energy absorbed is from the positrons themselves rather than the annihilation radiation. These considerations do not apply to the administration pathway for a radiopharmaceutical where the activity may be highly concentrated for a brief period rather than distributed in the body. Thus, high local radiation absorbed doses to the vein for an intravenous administration and to the upper airways during administration by inhalation can be expected. For these geometries, beta point source functions (FPS's) have been employed to estimate the radiation absorbed dose in the present study. Physiologic measurements were done to determine other exposure parameters for intravenous administration of O-15 and Rb-82 and for administration of O-15-CO 2 by continuous breathing. Using FPS's to calculate dose rates to the vein wall from O-15 and Rb-82 injected into a vein having an internal radius of 1.5 mm yielded dose rates of 0.51 and 0.46 (rad x g/μCi x h), respectively. The dose gradient in the vein wall and surrounding tissues was also determined using FPS's. Administration of O-15-CO 2 by continuous breathing was also investigated. Using ultra-thin thermoluninescent dosimeters (TLD's) having the effective thickness of normal tracheal mucosa, experiments were performed in which 6 dosimeters were exposed to known concentrations of O-15 positrons in a hemicylindrical tracheal phantom having an internal radius of 0.96 cm and an effective length of 14 cm. The dose rate for these conditions was 3.4 (rads/h)/(μCi/cm 3 ). 15 references, 7 figures, 6 tables

  13. Estimating doses and risks associated with decontamination and decommissioning activities using the CRRIS

    International Nuclear Information System (INIS)

    Miller, C.W.; Sjoreen, A.L.; Cotter, S.J.

    1986-01-01

    The Computerized Radiological Risk Investigation System (CRRIS) is applicable to determining doses and risks from a variety of decontamination and decommissioning activities. For example, concentrations in air from resuspended radionuclides initially deposited on the ground surface and the concentrations of deposited radionuclides in various soil layers can be obtained. The CRRIS will estimate exposure to radon and its progeny in terms of working-level months, and will compute the resulting health risks. The CRRIS consists of seven integrated computer codes that stand alone or are run as a system to calculate environmental transport, doses, and risks. PRIMUS output provides other CRRIS codes the capability to handle radionuclide decay chains. ANEMOS and RETADD-II calculate atmospheric dispersion and deposition for local and regional distances, respectively. Multiple ANEMOS runs for sources within a small area are combined on a master grid by SUMIT. MLSOIL is used to estimate effective ground surface concentrations for dose computations. TERRA calculates food chain transport, and ANDROS calculates individual or population exposures, doses, and risks. Applications of the CRRIS to decontamination problems are discussed. 16 refs., 1 fig

  14. Measurement of soil contamination by radionuclides due to the Fukushima Dai-ichi Nuclear Power Plant accident and associated estimated cumulative external dose estimation

    International Nuclear Information System (INIS)

    Endo, S.; Kimura, S.; Takatsuji, T.; Nanasawa, K.; Imanaka, T.; Shizuma, K.

    2012-01-01

    Soil sampling was carried out at an early stage of the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident. Samples were taken from areas around FDNPP, at four locations northwest of FDNPP, at four schools and in four cities, including Fukushima City. Radioactive contaminants in soil samples were identified and measured by using a Ge detector and included 129m Te, 129 Te, 131 I, 132 Te, 132 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba and 140 La. The highest soil depositions were measured to the northwest of FDNPP. From this soil deposition data, variations in dose rates over time and the cumulative external doses at the locations for 3 months and 1 y after deposition were estimated. At locations northwest of FDNPP, the external dose rate at 3 months after deposition was 4.8–98 μSv/h and the cumulative dose for 1 y was 51 to 1.0 × 10 3 mSv; the highest values were at Futaba Yamada. At the four schools, which were used as evacuation shelters, and in the four urban cities, the external dose rate at 3 months after deposition ranged from 0.03 to 3.8 μSv/h and the cumulative doses for 1 y ranged from 3 to 40 mSv. The cumulative dose at Fukushima Niihama Park was estimated as the highest in the four cities. The estimated external dose rates and cumulative doses show that careful countermeasures and remediation will be needed as a result of the accident, and detailed measurements of radionuclide deposition densities in soil will be important input data to conduct these activities.

  15. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    International Nuclear Information System (INIS)

    Lopez-Rendon, X.; Bosmans, H.; Zanca, F.; Oyen, R.

    2015-01-01

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  16. Effective dose and organ doses estimation taking tube current modulation into account with a commercial software package

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, X. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); Bosmans, H.; Zanca, F. [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Herestraat 49, box 7003, Leuven (Belgium); University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium)

    2015-07-15

    To evaluate the effect of including tube current modulation (TCM) versus using the average mAs in estimating organ and effective dose (E) using commercial software. Forty adult patients (24 females, 16 males) with normal BMI underwent chest/abdomen computed tomography (CT) performed with TCM at 120 kVp, reference mAs of 110 (chest) and 200 (abdomen). Doses to fully irradiated organs (breasts, lungs, stomach, liver and ovaries) and E were calculated using two versions of a dosimetry software: v.2.0, which uses the average mAs, and v.2.2, which accounts for TCM by implementing a gender-specific mAs profile. Student's t-test was used to assess statistically significant differences between organ doses calculated with the two versions. A statistically significant difference (p < 0.001) was found for E on chest and abdomen CT, with E being lower by 4.2 % when TCM is considered. Similarly, organ doses were also significantly lower (p < 0.001): 13.7 % for breasts, 7.3 % for lungs, 9.1 % for the liver and 8.5 % for the stomach. Only the dose to the ovaries was higher with TCM (11.5 %). When TCM is used, for the stylized phantom, the doses to lungs, breasts, stomach and liver decreased while the dose to the ovaries increased. (orig.)

  17. Dose estimates from protracted external exposure of inhabitants living in contaminated area of Russia after the Chernobyl accident

    International Nuclear Information System (INIS)

    Yonehara, H.; Sahoo, S.K.; Kurotaki, K.; Uchiyama, M.; Ramzaev, V.P.; Barishkov, N.; Mishin, A.; Barkovski, A.

    2000-01-01

    With respect to the radiation risk assessment, it is important to estimate the accurate doses of inhabitants, due to protracted exposure after the Chernobyl accident as well as the high doses just after the accident. We used a model for estimation of the dose with a long-term temporal change using information of dose rate on the ground and profile of the activity depth distribution in soil. A value C t [μSv h -1 /(MBq m -2 )], which is dose rate in air corresponding to the initial deposition of 137 Cs on the ground just after the accident, was analyzed using the results of the measurements of dose rate in air and activity in soil samples in the contaminated area of Bryansk region in Russia. From the analysis, the value, C 12 at 12 years after the accident can be predicted by categorizing usage of the land. The values obtained from the results of the actual measurement were 1.5 for forest, 1.0 for pasture, 0.6 for yard, and 0.45 for arable or kitchen garden. Temporal change of C t was estimated with a vertical migration model of activity in soil developed by Golikov et al. Annual dose due to 137 Cs and 134 Cs contamination in the period from 1987 to 1999 in farmers, and forest workers were estimated by the model using above values. The results were in good agreement with those obtained by using the personal dose monitoring. The cumulative doses of the inhabitants estimated by the model range from 10 to 60 mSv. (author)

  18. Influence of TLD position on the estimate of fetal dose

    International Nuclear Information System (INIS)

    Majola, J.; Jamieson, T.J.

    1995-11-01

    This report examines the adequacy of the practice of using a single dosimeter worn at the front of the body as an estimate of the dose received by nuclear medicine technologies. In order to investigate this, a group of approximately 50 technologists at 9 different hospitals were double-badged, i.e. provided with front and back dosimeters, and the ratio of front to back dose computed. Both aggregate data and hospital-specific data are presented and accompanied by several forms of statistical analysis. Apparent trends and possible explanations are discussed. Recommendations are provided for additional studies relating to the badging of nuclear medicine technologists. (author). 125 refs., 15 tabs., 13 figs

  19. Influence of TLD position on the estimate of fetal dose

    Energy Technology Data Exchange (ETDEWEB)

    Majola, J; Jamieson, T J [Science Applications International Corp., Ottawa, ON (Canada)

    1995-11-01

    This report examines the adequacy of the practice of using a single dosimeter worn at the front of the body as an estimate of the dose received by nuclear medicine technologies. In order to investigate this, a group of approximately 50 technologists at 9 different hospitals were double-badged, i.e. provided with front and back dosimeters, and the ratio of front to back dose computed. Both aggregate data and hospital-specific data are presented and accompanied by several forms of statistical analysis. Apparent trends and possible explanations are discussed. Recommendations are provided for additional studies relating to the badging of nuclear medicine technologists. (author). 125 refs., 15 tabs., 13 figs.

  20. Assessment of intraoperative 3D imaging alternatives for IOERT dose estimation

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Vazquez, Veronica; Marinetto, Eugenio [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Guerra, Pedro [Univ. Politecnica de Madrid (Spain). Dept. de Ingenieria Electronica; Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza (Spain); Valdivieso-Casique, Manlio Fabio [GMV SA, Madrid (Spain); Calvo, Felipe Angel [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Hospital General Univ. Gregorio Maranon, Madrid (Spain). Dept. de Oncologia; Univ. Complutense de Madrid (Spain). Facultad de Medicina; Alvarado-Vazquez, Eduardo [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Hospital General Univ. Gregorio Maranon, Madrid (Spain). Servicio de Oncologia Radioterapica; Sole, Claudio Vicente [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Instituto de Radiomedicina, Santiago (Chile). Service of Radiation Oncology; Vosburgh, Kirby Gannett [Harvard Medical School, Brigham and Women' s Hospital, Boston, MA (United States). Department of Radiology; Desco, Manuel; Pascau, Javier [Instituto de Investigacion Sanitaria Gregorio Maranon, Madrid (Spain); Univ. Carlos III de Madrid (Spain). Dept. de Bioingenieria e Ingenieria Aeroespacial; Centro de Investigacion Biomedica en Red de Salud Mental (CIBERSAM), Madrid (Spain)

    2017-10-01

    Intraoperative electron radiation therapy (IOERT) involves irradiation of an unresected tumour or a post-resection tumour bed. The dose distribution is calculated from a preoperative computed tomography (CT) study acquired using a CT simulator. However, differences between the actual IOERT field and that calculated from the preoperative study arise as a result of patient position, surgical access, tumour resection and the IOERT set-up. Intraoperative CT imaging may then enable a more accurate estimation of dose distribution. In this study, we evaluated three kilovoltage (kV) CT scanners with the ability to acquire intraoperative images. Our findings indicate that current IOERT plans may be improved using data based on actual anatomical conditions during radiation. The systems studied were two portable systems (''O-arm'', a cone-beam CT [CBCT] system, and ''BodyTom'', a multislice CT [MSCT] system) and one CBCT integrated in a conventional linear accelerator (LINAC) (''TrueBeam''). TrueBeam and BodyTom showed good results, as the gamma pass rates of their dose distributions compared to the gold standard (dose distributions calculated from images acquired with a CT simulator) were above 97% in most cases. The O-arm yielded a lower percentage of voxels fulfilling gamma criteria owing to its reduced field of view (which left it prone to truncation artefacts). Our results show that the images acquired using a portable CT or even a LINAC with on-board kV CBCT could be used to estimate the dose of IOERT and improve the possibility to evaluate and register the treatment administered to the patient.

  1. Dose estimation in embryo or fetus in external fields; Estimacion de dosis en embrion o feto

    Energy Technology Data Exchange (ETDEWEB)

    Gregori, Beatriz N [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina)

    2001-07-01

    The embryo or the fetus can be irradiated as result of radiological procedures of diagnosis of therapy in where the beam effects directly on the same one or in tissues or peripherical organs. Some authors have suggested that in the first stages of the pregnancy the dose in ovaries can be the good estimated of the dose in embryo or fetus. In advanced conditions of the development, probably also in the early stage, is more appropriated to specify the dose in the embryo or fetus equal of the uterus. The dose in the uterus is a good estimated so much for external irradiation as for radionuclides incorporation.

  2. Preliminary radiological assessments of near-surface low-level radioactive waste repositories

    International Nuclear Information System (INIS)

    Sumerling, T.J.; Nancarrow, D.J.

    1988-08-01

    This report summarises preliminary assessments of post-closure radiological impact of LLW repositories at four sites previously under investigation by UK Nirex Ltd. The objectives of the assessments were: to demonstrate a methodology for site specific assessments, to identify important information requirements for detailed assessments; to identify methodological and research requirements. Doses and risks due to groundwater pathways, human intrusion, gaseous release and natural environmental change are estimated. (author)

  3. Estimation of absorbed doses from paediatric cone-beam CT scans: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry T; Toncheva, Greta; Frush, Donald P; Yin, Fang-Fang

    2010-03-01

    The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of the Varian On-Board Imager((R)) was built in the MC system. To validate the model, the absorbed doses at each organ location for standard-dose and low-dose modes were measured in the physical phantom with MOSFET detectors; effective doses were also calculated. In the results, the MC simulations were comparable to the MOSFET measurements. This voxelised phantom approach could produce a more accurate dose estimation than the stylised phantom method. This model can be easily applied to multi-detector CT dosimetry.

  4. Effect of tube current modulation for dose estimation using a simulation tool on body CT examination

    International Nuclear Information System (INIS)

    Kawaguchi, Ai; Matsunaga, Yuta; Kobayashi, Masanao; Suzuki, Shoichi; Matsubara, Kosuke; Chida, Koichi

    2015-01-01

    The purpose of this study was to evaluate the effect of tube current modulation for dose estimation of a body computed tomography (CT) examination using a simulation tool. The authors also compared longitudinal variations in tube current values between iterative reconstruction (IR) and filtered back-projection (FBP) reconstruction algorithms. One hundred patients underwent body CT examinations. The tube current values around 10 organ regions were recorded longitudinally from tube current information. The organ and effective doses were simulated by average tube current values and longitudinal modulated tube current values. The organ doses for the bladder and breast estimated by longitudinal modulated tube current values were 20 % higher and 25 % lower than those estimated using the average tube current values, respectively. The differences in effective doses were small (mean, 0.7 mSv). The longitudinal variations in tube current values were almost the same for the IR and FBP algorithms. (authors)

  5. Estimate of whole body doses for Lynette Tew and Becky Farnsworth from Nevada Test Site local fallout

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Ng, Y.C.

    1985-01-01

    Lynette Tew and Becky Farnsworth are decendents whose relatives are litigants in Timothy vs US. The litigants allege that the decendents were harmed by radiation doses received as a result of local fallout from the testing of nuclear weapons at the Nevada Test Site. We have calculated a best estimate of the whole body dose received by each decendent from external exposure and the ingestion of radionuclides with food. In each case the dose via ingestion is trivial compared to the external dose. For Lynette Tew the dose estimate is 0.28 rads. For Becky Farnsworth it is 0.0035 rads. 23 references, 4 tables

  6. Parameters used in the environmental pathways and radiological dose modules of the Phase I air pathway code

    International Nuclear Information System (INIS)

    Shindle, S.F.; Ikenberry, T.A.; Napier, B.A.

    1992-05-01

    This report is a description of work performed for the Hanford Environmental Dose Reconstruction (HEDR) Project. The HEDR Project was established to estimate radiation doses to individuals resulting from releases of radionuclides from the Hanford Site since 1944, when facilities there first began operating. An independent Technical Steering Panel directs the project, which is conducted by Battelle staff from the Pacific Northwest Laboratory. The objective of Phase 1 of the HEDR Project was to demonstrate through calculation that adequate models and support data existed or could be developed to allow estimation of realistic doses to individuals from historical Hanford Site radionuclide releases. The HEDR Phase 1 computer code was used to model the transport of iodine-131 released to the atmosphere from the Hanford Site facilities, through environmental pathways to points of human exposure. Output from the code was preliminary estimates of doses received by members of the public living in the vicinity of the Hanford Site. Later project work continues to build upon Phase 1 progress in order to refine dose estimates

  7. Estimation of Collective Effective Dose Due to Cosmic Ray Exposures to Members of The Public and to Airline Passenger

    International Nuclear Information System (INIS)

    Sayed, N.S.; Salah Eldin, T.; Gomaa, M.A.; El Dosoky, T.M.

    2011-01-01

    Using UNSCEAR 2000 report to United Nation General Assembly and its appendices, Annual collective dose to Egyptian members of the public (75097301). Was estimated to be 252.5 man Sv , hence the average collective effective dose to air line passenger for 10 million is estimated as 25.25 micro Sievert. Furthermore using hypothetical approach for Egyptian passengers who fly locally, regionally and internationally, the collective dose was estimated to be 252.5 man Sv , hence the average average collective effective dose for Egyptian passenger is due to Aviation is 3.36 micro Sievert

  8. Feasibility of using the computed tomography dose indices to estimate radiation dose to partially and fully irradiated brains in pediatric neuroradiology examinations

    International Nuclear Information System (INIS)

    Januzis, Natalie; Nguyen, Giao; Yoshizumi, Terry T; Frush, Donald P; Hoang, Jenny K; Lowry, Carolyn

    2015-01-01

    The purpose of this study was two-fold: (a) to measure the dose to the brain using clinical protocols at our institution, and (b) to develop a scanner-independent dosimetry method to estimate brain dose. Radiation dose was measured with a pediatric anthropomorphic phantom and MOSFET detectors. Six current neuroradiology protocols were used: brain, sinuses, facial bones, orbits, temporal bones, and craniofacial areas. Two different CT vendor scanners (scanner A and B) were used. Partial volume correction factors (PVCFs) were determined for the brain to account for differences between point doses measured by the MOSFETs and average organ dose. The CTDI vol and DLP for each protocol were recorded. The dose to the brain (mGy) for scanners A and B was 10.7 and 10.0 for the brain protocol, 7.8 and 3.2 for the sinus, 10.2 and 8.6 for the facial bones, 7.4 and 4.7 for the orbits and 1.6 and 1.9 for the temporal bones, respectively. On scanner A, the craniofacial protocol included a standard and high dose option; the dose measured for these exams was 3.9 and 16.9 mGy, respectively. There was only one craniofacial protocol on scanner B; the brain dose measured on this exam was 4.8 mGy. A linear correlation was found between DLP and brain dose with the conversion factors: 0.049 (R 2 = 0.87), 0.046 (R 2 = 0.89) for scanner A and B, and 0.048 (R 2 = 0.89) for both scanners. The range of dose observed was between 1.8 and 16.9 mGy per scan. This suggests that brain dose estimates may be made from DLP. (paper)

  9. Biodistribution parameters and radiation absorbed dose estimates for radiolabeled human low density lipoprotein

    International Nuclear Information System (INIS)

    Hay, R.V.; Ryan, J.W.; Williams, K.A.; Atcher, R.W.; Brechbiel, M.W.; Gansow, O.A.; Fleming, R.M.; Stark, V.J.; Lathrop, K.A.; Harper, P.V.

    1992-01-01

    The authors propose a model to generate radiation absorbed dose estimates for radiolabeled low density lipoprotein (LDL), based upon eight studies of LDL biodistribution in three adult human subjects. Autologous plasma LDL was labeled with Tc-99m, I-123, or In-111 and injected intravenously. Biodistribution of each LDL derivative was monitored by quantitative analysis of scintigrams and direct counting of excreta and of serial blood samples. Assuming that transhepatic flux accounts for the majority of LDL clearance from the bloodstream, they obtained values of cumulated activity (A) and of mean dose per unit administered activity (D) for each study. In each case highest D values were calculated for liver, with mean doses of 5 rads estimated at injected activities of 27 mCi, 9 mCi, and 0.9 mCi for Tc-99m-LDL, I-123-LDL, and In-111-LDL, respectively

  10. Experiments, conceptual design, preliminary cost estimates and schedules for an underground research facility

    International Nuclear Information System (INIS)

    Korbin, G.; Wollenberg, H.; Wilson, C.; Strisower, B.; Chan, T.; Wedge, D.

    1981-09-01

    Plans for an underground research facility are presented, incorporating techniques to assess the hydrological and thermomechanical response of a rock mass to the introduction and long-term isolation of radioactive waste, and to assess the effects of excavation on the hydrologic integrity of a repository and its subsequent backfill, plugging, and sealing. The project is designed to utilize existing mine or civil works for access to experimental areas and is estimated to last 8 years at a total cost for contruction and operation of $39.0 million (1981 dollars). Performing the same experiments in an existing underground research facility would reduce the duration to 7-1/2 years and cost $27.7 million as a lower-bound estimate. These preliminary plans and estimates should be revised after specific sites are identified which would accommodate the facility

  11. Estimation of the absorbed dose in gamma irradiated food containing bone by electron spin resonance spectroscopy

    International Nuclear Information System (INIS)

    Basfar, A.A.; Abdel Rehim, F.

    1997-01-01

    The use of electron spin resonance (ESR) spectroscopy to accurately evaluate the absorbed dose to radiationprocessed bones (and thus meats) is examined. The exposure of foodstuffs containing bone to a dose of ionizing radiation results in the formation of long lived free radicals which give rise to characteristics ESR signals. The yield of radicals was found to be proportional to absorbed dose. Additive re-irradiation of previously irradiated bone was used to estimate the absorbed dose in the irradiated chicken bone. Simple non-linear rational equation was found to fit to the data and yields good dose estimates for irradiated bone in the range of doses (1.0 - 5.0 kGy). Decay of the ESR signal intensity was monitored at different dose levels (2.0 and 7.0 kGy) up to 22 days. The absorbed dose in irradiated chicken (2.Om 3.0 and 6.0 kGy) was assessed at 2, 6 and 12 days after irradiation. Relatively good results were obtained when measurements were made within the following days (up to 12 days) after irradiation. The ability of the dose additive method to provide accurate dose assessments is tested here

  12. A new online detector for estimation of peripheral neutron equivalent dose in organ

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L., E-mail: leticia@us.es; Sanchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009, Spain and Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Lorenzoli, M.; Pola, A. [Departimento di Ingegneria Nuclear, Politecnico di Milano, Milano 20133 (Italy); Bedogni, R. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN), Frascati Roma 00044 (Italy); Terrón, J. A. [Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Sanchez-Nieto, B. [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago 4880 (Chile); Expósito, M. R. [Departamento de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Lagares, J. I.; Sansaloni, F. [Centro de Investigaciones Energéticas y Medioambientales y Tecnológicas (CIEMAT), Madrid 28040 (Spain)

    2014-11-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  13. A new online detector for estimation of peripheral neutron equivalent dose in organ

    International Nuclear Information System (INIS)

    Irazola, L.; Sanchez-Doblado, F.; Lorenzoli, M.; Pola, A.; Bedogni, R.; Terrón, J. A.; Sanchez-Nieto, B.; Expósito, M. R.; Lagares, J. I.; Sansaloni, F.

    2014-01-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  14. Estimation of patient dose in 18 F-FDG and 18 F-FDOPA PET/CT examinations

    Directory of Open Access Journals (Sweden)

    Aruna Kaushik

    2013-01-01

    Full Text Available Purpose: To estimate specific organ and effective doses to patients resulting from the 18 F-FDG ( 18 F-2-deoxy-D-glucose and 18 F-FDOPA (6-fluoro-( 18 F-L-3, 4-dihydroxyphenylalanine PET/CT examinations for whole body and brain. Materials and Methods: Three protocols for whole body and three for brain PET/CT were used. The CTDI values were measured using standard head and body CT phantoms and also computed using a software CT-Expo for dose evaluation from the CT component. OLINDA software based on MIRD method was used for estimating doses from the PET component of the PET/CT examination. Results: The organ doses from 18 F-FDG and 18 F-FDOPA whole body and brain PET/CT studies were estimated. The total effective dose from a typical protocol of whole body PET/CT examination was 14.4 mSv for females and 11.8 mSv for male patients from 18 F-FDG, whereas it was 11 mSv for female and 9.1 mSv for male patients from 18 F-FDOPA. The total effective doses from a typical protocol for PET/CT studies of brain was 6.5 mSv for females and 5.1 mSv for males from 18 F-FDG whereas it was 3.7 mSv for females and 2.8 mSv for males from 18 F-FDOPA. Conclusions: The effective radiation doses from whole body PET/CT examination was approximately 4-8 times higher than the background radiation dose from both 18 F-FDG and 18 F-FDOPA scans, while it was 1-3 times the background radiation dose from PET/CT scans of brain.

  15. Measurement and estimation of maximum skin dose to the patient for different interventional procedures

    International Nuclear Information System (INIS)

    Cheng Yuxi; Liu Lantao; Wei Kedao; Yu Peng; Yan Shulin; Li Tianchang

    2005-01-01

    Objective: To determine the dose distribution and maximum skin dose to the patient for four interventional procedures: coronary angiography (CA), hepatic angiography (HA), radiofrequency ablation (RF) and cerebral angiography (CAG), and to estimate the definitive effect of radiation on skin. Methods: Skin dose was measured using LiF: Mg, Cu, P TLD chips. A total of 9 measuring points were chosen on the back of the patient with two TLDs placed at each point, for CA, HA and RF interventional procedures, whereas two TLDs were placed on one point each at the postero-anterior (PA) and lateral side (LAT) respectively, during the CAG procedure. Results: The results revealed that the maximum skin dose to the patient was 1683.91 mGy for the HA procedure with a mean value of 607.29 mGy. The maximum skin dose at the PA point was 959.3 mGy for the CAG with a mean value of 418.79 mGy; While the maximum and the mean doses at the LAT point were 704 mGy and 191.52 mGy, respectively. For the RF procedure the maximum dose was 853.82 mGy and the mean was 219.67 mGy. For the CA procedure the maximum dose was 456.1 mGy and the mean was 227.63 mGy. Conclusion: All the measured dose values in this study are estimated ones which could not provide the accurate maximum value because it is difficult to measure using a great deal of TLDs. On the other hand, the small area of skin exposed to high dose could be missed as the distribution of the dose is successive. (authors)

  16. Estimation of doses received in a dry-contaminated residential area in the Bryansk region, Russia, since the Chernobyl accident

    International Nuclear Information System (INIS)

    Andersson, K.G.; Roed, J.

    2006-01-01

    In nuclear preparedness, an essential requirement is the ability to adequately predict the likely consequences of a major accident situation. In this context it is very important to evaluate which contributions to dose are important, and which are not likely to have significance. As an example of this type of evaluation, a case study has been conducted to estimate the doses received over the first 17 years after the Chernobyl accident in a dry-contaminated residential area in the Bryansk region in Russia. Methodologies for estimation of doses received through nine different pathways, including contamination of streets, roofs, exterior walls, and landscape, are established, and best estimates are given for each of the dose contributions. Generally, contaminated soil areas were estimated to have given the highest dose contribution, but a number of other contributions to dose, e.g., from contaminated roofs and inhalation of contaminants during the passage of the contaminated plume, were of the same order of magnitude

  17. Estimation of personal dose based on the dependent calibration of personal dosimeters in interventional radiology

    International Nuclear Information System (INIS)

    Mori, Hiroshige; Koshida, Kichiro; Ichikawa, Katsuhiro

    2007-01-01

    The purpose of present study is, in interventional radiology (IVR), to elucidate the differences between each personal dosimeter, and the dependences and calibrations of area or personal dose by measurement with electronic dosimeters in particular. We compare space dose rate distributions measured by an ionization survey meter with the value measured by personal dosimeter: an optically stimulated luminescence, two fluoroglass, and two electronic dosimeters. Furthermore, with electronic dosimeters, we first measured dose rate, energy, and directional dependences. Secondly, we calibrated the dose rate measured by electronic dosimeters with the results, and estimated these methods with coefficient of determination and Akaike's Information Criterion (AIC). The results, especially in electronic dosimeters, revealed that the dose rate measured fell by energy and directional dependences. In terms of methods of calibration, the method is sufficient for energy dependence, but not for directional dependence, because of the lack of stable calibration. This improvement poses a question for the future. The study suggested that these dependences of the personal dosimeter must be considered when area or personal dose is estimated in IVR. (author)

  18. Environmental factors used for the estimation of radiation dose to thyroid gland

    International Nuclear Information System (INIS)

    Ohmomo, Yoichiro

    1976-01-01

    Environmental factors used for the estimation of radiation dose to thyroid gland were discussed in this paper, such as deposition velocity of radioactive iodine onto plant leaves, elimination factor from the leaves, transfer of this nuclide to milk and the consumption of those critical foods especially by inhabitants around nuclear sites in coastal area of Ibaraki Prefecture. Uptake of the stable iodine was estimated. (auth.)

  19. Preliminary study of dose equivalent evaluation for residents in radioactivity contaminated rebar buildings

    International Nuclear Information System (INIS)

    Chen, W.L.; Liao, C.C.; Wang, M.T.; Chen, F. D.

    1998-01-01

    It has recently been found that several resident and office buildings in Taiwan were constructed with 60 Co-contaminated reinforcing steel bar (rebar). Both governmental officials and the residents of such buildings have been concerned about this finding. In order to respond to the situation, the government has adopted a number of remedial measures, including full-scale radiation survey, dose evaluation and physical examinations of residents. This article presents three methods for evaluating the dose equivalents of the residents living in the contaminated rebar buildings by means of γ-ray survey, necklace-type thermoluminescence dosimeters (TLDs) and the human lymphocyte chromosome aberration analyses. The results reveal that the dose evaluation by γ-ray survey is rather conservative. Generally for the residents whose annual dose equivalents are greater than 5 mSv (0.5 rem) by γ-ray survey, the dose equivalents from necklace-type TLDs are only within the range of 20 to 50% of the evaluated values mentioned above. For chromosome analyses, at least 500 lymphocyte cells were scored and analyzed for each resident. Most of the chromosome analysis data show that the dose equivalents received by residents are lower than the detection limit of the method (100 mSv) and quite different from the estimated dose obtained from either γ-ray survey or necklace-type TLD measurements

  20. Estimated radiation doses to different organs among patients treated for ankylosing spondylitis with a single course of X rays

    International Nuclear Information System (INIS)

    Lewis, C.A.; Smith, P.G.; Stratton, I.M.; Darby, S.C.; Doll, R.

    1988-01-01

    A follow-up study of over 14000 patients treated with a single course of X rays for ankylosing spondylitis demonstrated substantial excess risk of developing cancer. Previously the excess risk of leukaemia has been related to the estimated mean radiation dose to active bone marrow but detailed estimates were not made of the radiation doses to other organs. Data extracted from the original treatment records of a random sample of one in 15 patients have been used to make dose estimates, using Monte Carlo methods, for 30 specific organs or body regions and 12 bone marrow sites. Estimates of mean and median organ doses, standard deviations and ranges have been tabulated. Detailed distributions are presented for six organs (lung, bronchi, stomach, oesophagus, active bone marrow and total body). Comparison with the earlier bone marrow estimates and more recent theoretical estimates shows good agreement. (author)

  1. Reliability of single aliquot regenerative protocol (SAR) for dose estimation in quartz at different burial temperatures: A simulation study

    International Nuclear Information System (INIS)

    Koul, D.K.; Pagonis, V.; Patil, P.

    2016-01-01

    The single aliquot regenerative protocol (SAR) is a well-established technique for estimating naturally acquired radiation doses in quartz. This simulation work examines the reliability of SAR protocol for samples which experienced different ambient temperatures in nature in the range of −10 to 40 °C. The contribution of various experimental variables used in SAR protocols to the accuracy and precision of the method is simulated for different ambient temperatures. Specifically the effects of paleo-dose, test dose, pre-heating temperature and cut-heat temperature on the accuracy of equivalent dose (ED) estimation are simulated by using random combinations of the concentrations of traps and centers using a previously published comprehensive quartz model. The findings suggest that the ambient temperature has a significant bearing on the reliability of natural dose estimation using SAR protocol, especially for ambient temperatures above 0 °C. The main source of these inaccuracies seems to be thermal sensitization of the quartz samples caused by the well-known thermal transfer of holes between luminescence centers in quartz. The simulations suggest that most of this inaccuracy in the dose estimation can be removed by delivering the laboratory doses in pulses (pulsed irradiation procedures). - Highlights: • Ambient temperatures affect the reliability of SAR. • It overestimates the dose with increase in burial temperature and burial time periods. • Elevated temperature irradiation does not correct for these overestimations. • Inaccuracies in dose estimation can be removed by incorporating pulsed irradiation procedures.

  2. Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer

    International Nuclear Information System (INIS)

    Ho, S.; Lau, W.Y.; Leung, T.W.T.; Chan, M.; Johnson, P.J.; Li, A.K.C.

    1997-01-01

    Radiation doses to the tumour and non-tumorous liver compartments from yttrium-90 microspheres in the treatment of hepatic cancer, as estimated by a partition model, have been verified by correlation with the actual doses measured with a beta probe at open surgery. The validity of the doses to the lungs, the tumour and non-tumours liver compartment as estimated by the partition model was further evaluated in clinical settings. On the basis of the observation that one of three patients who received more than 30 Gy from a single treatment and one of two patients who received more than 50 Gy from multiple treatments developed radiation pneumonitis, it was deduced that an estimated lung dose 30 Gy as estimated by the partition model and were predicted to develop radiation pneumonitis, did so despite the use of partial hepatic embolization to reduce the degree of lung shunting. Furthermore, a higher radiological response rate and prolonged survival were found in the group of patients who received higher tumour doses, as estimated by the partition model, than in the group with lower estimated tumour doses. Thus the radiation doses estimated by the partition model can be used to predict (a) complication rate, (b) response rate and (c) duration of survival in the same manner as the actual radiation doses measured with a beta probe at open surgery. The partition model has made selective internal radiation therapy using 90 Y microspheres safe and repeatable without laparotomy. (orig.)

  3. Estimation of breast doses and breast cancer risk associated with repeated fluoroscopic chest examinations of women with tuberculosis

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Rosenstein, M.; Trout, E.D.

    1978-01-01

    A methodology is presented to estimate cumulative breast dose and breast cancer risk for women exposed to repeated fluoroscopic chest examinations during air collapse therapy for pulmonary tuberculosis. Medical record abstraction, physician interview, patient contact, machine exposure measurements, and absorbed dose computations were combined to estimate average breast doses for 1047 Massachusetts women who were treated between 1930 and 1954. The methodology presented considers breast size and composition, patient orientation, x-ray field size and location, beam quality, type of examination, machine exposure rate, and exposure time during fluoroscopic examinations. The best estimate for the risk of radiation-induced cancer for the women living longer than 10 years after initial fluoroscopic exposure is 6.2 excess breast cancers per million woman-year-rad with 90% confidence limits of 2.8 and 10.7 cancers/10 6 WY-rad. When breast cancer risk is considered as a function of absorbed dose in the breast, instead of as a function of the number of fluoroscopic examinations, a linear dose--response relationship over the range of estimated doses is consistent with the data. However, because of the uncertainty due to small-sample variability and because of the wide range of assumptions regarding certain fluoroscopy conditions, other dose--response relationships are compatible with the data

  4. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  5. Intercomparison of iodine thyroid doses estimated for people living in urban and rural environments

    International Nuclear Information System (INIS)

    Voigt, G.

    2000-01-01

    The radioecological model ECOSYS, developed in GSF-Institut fuer Strahlenschutz has been applied to calculate thyroid doses to the population due to I-131 exposures after the Chernobyl accident. The main contribution to the thyroid doses calculated is given by the consumption of milk and vegetables. Results are presented taking into account the different activity concentrations measured in milk of private family cows and mixed collective milk of a creamery in upper Bavaria, as well as different consumption behaviour of children and adults in rural and urban areas. Thyroid doses due to different milk consumption habits and a different milk origin in adults living in urban environments are estimated to be up to 12 times, in children up to 3 times lower than those estimated for rural environments. The dose contribution by vegetables, however, in any case exceeded the one by milk because of the high intake rates for the case investigated here. These values, however, may be overestimates for vegetables and have a very high uncertainty. For adults total thyroid dose by ingestion was higher in rural areas by a factor of 1.4, for children at the age of 10 years, total thyroid dose by ingestion was 1.5 times higher in urban environments for the conditions described here. (author)

  6. Estimation of build up of dose rate on U3O8 product drum

    International Nuclear Information System (INIS)

    Pandey, J.P.N.; Shinde, A.M.; Deshpande, M.D.

    2008-01-01

    In fuel reprocessing plant, plutonium oxide and uranium oxide (U 3 O 8 ) are products. Approximately 180 kg U 3 O 8 is filled in SS drum and sealed firmly before storage. In PHWR natural uranium (UO 2 ) is used as fuel. In natural uranium, thorium-232 is present as an impurity at few tens of ppm level. During irradiation in power reactors, due to nuclear reaction formation of 232 U from 232 Th takes place. Natural decay of 232 U leads to the formation of 208 Tl. As time passes, there is buildup of 208 Tl and hence increase in dose rate on the drum containing U 3 O 8 . It is essential to estimate the buildup of dose rate considering the external radiological hazards involved during U 3 O 8 drum handling, transportation and fuel fabrication. This paper describes the calculation of dose rate on drum in future years using MCNP code. For dose rate calculation decay of fission product activity which remains as contamination in product and build up of '2 08 Tl from 232 U is considered. Some measured values of dose rate on U 3 O 8 drum are given for the comparisons with estimated dose rate based on MCNP code. (author)

  7. Radiocesium and polonium in seals from the Baltic Sea. A preliminary study

    International Nuclear Information System (INIS)

    Holm, E.; Leisvik, M.

    2002-01-01

    137 Cs and 210 Po in muscle, liver and kidney from 5 seals from the Baltic Sea have been studied. Assuming that the seals consume 5% of their own body weight each day and by using previously obtained data for the doses in fish, the biological half time has been estimated to 20 days for Cesium and 35 days for Polonium. The maximum yearly doses are calculated to 76 μGy from 137 CS to muscle and 3 500 μGy to kidneys from 210 Po. These data are very preliminary, the number of individuals being so small, and it is difficult to estimate how much food other than fish the seals consume. Furthermore only few data for radioactive concentrations in whole fish exist, which especially impacts the results for Polonium. (LN)

  8. Identification of irradiated meat using electron spin resonance (ESR) spectroscopy and estimation of applied dose using re-irradiation

    International Nuclear Information System (INIS)

    Chawla, S.P.; Thomas, Paul; Bongirwar, D.R.

    2001-01-01

    An in-house blind trail on bone-in meat chunks was carried out in which 35 coded samples were correctly identified. The samples were either left unirradiated or had been irradiated to dose of 1, 2.5 or 4 kGy. Using re-irradiation, the dose received by the samples were determined with either linear, quadratic or exponential equation. The quadratic or exponential equation gave more successful estimates of irradiation dose whereas linear fit equations tend to over estimate the dose. (author)

  9. Risks of circulatory diseases among Mayak PA workers with radiation doses estimated using the improved Mayak Worker Dosimetry System 2008

    Energy Technology Data Exchange (ETDEWEB)

    Moseeva, Maria B.; Azizova, Tamara V.; Grigoryeva, Evgenia S. [Southern Urals Biophysics Institute (SUBI), Ozyorsk, Chelyabinsk Region (Russian Federation); Haylock, Richard [Public Health of England, London (United Kingdom)

    2014-05-15

    The new Mayak Worker Dosimetry System 2008 (MWDS-2008) was published in 2013 and supersedes the Doses-2005 dosimetry system for Mayak Production Association (PA) workers. It provides revised external and internal dose estimates based on the updated occupational history data. Using MWDS-2008, a cohort of 18,856 workers first employed at one of the main Mayak PA plants during 1948-1972 and followed up to 2005 was identified. Incidence and mortality risks from ischemic heart disease (IHD) (International Classification of Diseases (ICD)-9 codes 410-414) and from cerebrovascular diseases (CVD) (ICD-9 codes 430-438) were examined in this cohort and compared with previously published risk estimates in the same cohort based on the Doses-2005 dosimetry system. Significant associations were observed between doses from external gamma-rays and IHD and CVD incidence and also between internal doses from alpha-radiation and IHD mortality and CVD incidence. The estimates of excess relative risk (ERR)/Gy were consistent with those estimates from the previous studies based on Doses-2005 system apart from the relationship between CVD incidence and internal liver dose where the ERR/Gy based on MWDS-2008 was just over three times higher than the corresponding estimate based on Doses-2005 system. Adjustment for smoking status did not show any effect on the estimates of risk from internal alpha-particle exposure. (orig.)

  10. Survey of food radioactivity and estimation of internal dose from ingestion in China

    International Nuclear Information System (INIS)

    Zhang Jingyuan; Zhu Hongda; Han Peizhen

    1988-01-01

    In order to provide necessary bases for establishing 'Radionuclide Concentration Limits in Food stuffs', survey on radionuclide contents in Chinese food and estimation of internal dose from ingestion were carried out with the cooperation of 30 radiation protection establishments during the period 1982-1986. Activity concentrations in 14 categories (27 kinds) of Chinese food for 22 radionuclides were determined. In the light of three principal types of Chinese diet, food samples were collected from normal radiation background areas in 14 provinces or autonomous regions and three similarly elevated natural background areas. Annual intake by ingestion and resultant committed dose equivalents to general public for 15 radionuclides in these areas were estimated. In normal background areas the total annual intake of the 15 radionuclides by the public (adlut males) is about 4.2 x 10 4 Bq, and the resultant total committed dose equivalent is about 3.43 x 10 -4 Sv, but in two elevated natural background area the public annual intake and resulting committed dose equivalents for some natural radionulides are much higher than those in normal areas, while no obvious radiocontamination was discoveried relative contribution of each food category or each radionuclide to the total are discussed

  11. Development of dose rate estimation system for FBR maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Iizawa, Katsuyuki [Japan Nuclear Cycle Development Inst., Tsuruga Head Office, International Cooperation and Technology Development Center, Tsuruga, Fukui (Japan); Takeuchi, Jun; Yoshikawa, Satoru [Hitachi Engineering Company, Ltd., Hitachi, Ibaraki (Japan); Urushihara, Hiroshi [Ibaraki Hitachi Information Service Co., Ltd., Omika, Ibaraki (Japan)

    2001-09-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  12. Development of dose rate estimation system for FBR maintenance

    International Nuclear Information System (INIS)

    Iizawa, Katsuyuki; Takeuchi, Jun; Yoshikawa, Satoru; Urushihara, Hiroshi

    2001-01-01

    During maintenance activities on the primary sodium cooling system by an FBR Personnel radiation exposure arises mainly from the presence of radioactive corrosion products (CP). A CP behavior analysis code, PSYCHE, and a radiation shielding calculation code, QAD-CG, have been developed and applied to investigate the possible reduction of radiation exposure of workers. In order to make these evaluation methods more accessible to plant engineers, the user interface of the codes has been improved and an integrated system, including visualization of the calculated gamma-ray radiation dose-rate map, has been developed. The system has been verified by evaluating the distribution of the radiation dose-rate within the Monju primary heat transport system cells from the estimated saturated CP deposition and distribution which would be present following about 20 cycles of full power operation. (author)

  13. Estimation of the genetically significant dose resulting from diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1978-01-01

    Based on the average gonad dose received per examination or per film and on the frequency of x-ray examinations (36 million per annum), the mean annual gonad dose to individuals in the GDR has been determined to be 33 mR. Considering different age groups of patients and the fact that the gonad dose to children is often significantly reduced in comparison to adults, estimates of the genetically significant dose (GSD) range from 7 to 19 mR per annum. Examinations of women have accounted for about 66 per cent of the GSD. The highest contribution to the GSD result from examinations of the following organs: kidneys, colon, bile duct (only in women), lumbar spine, pelois, hips, and proximal femur. Despite their high frequency, examinations of the stomach account for only about 3 per cent of the GSD. All thorax examinations (nearly 10,000,000 per annum) contribute less than 0.5 per cent, and the most frequent x-ray examinations of the skeletal system, skull, cervical spine, and teeth account for less than 3 per cent. The GSD values obtained are comparable with those from countries such as India, Japan, Netherlands, USSR, and USA. (author)

  14. Environmental radioactivity in the UK: the airborne geophysical view of dose rate estimates

    International Nuclear Information System (INIS)

    Beamish, David

    2014-01-01

    This study considers UK airborne gamma-ray data obtained through a series of high spatial resolution, low altitude surveys over the past decade. The ground concentrations of the naturally occurring radionuclides Potassium, Thorium and Uranium are converted to air absorbed dose rates and these are used to assess terrestrial exposure levels from both natural and technologically enhanced sources. The high resolution airborne information is also assessed alongside existing knowledge from soil sampling and ground-based measurements of exposure levels. The surveys have sampled an extensive number of the UK lithological bedrock formations and the statistical information provides examples of low dose rate lithologies (the formations that characterise much of southern England) to the highest sustained values associated with granitic terrains. The maximum dose rates (e.g. >300 nGy h −1 ) encountered across the sampled granitic terrains are found to vary by a factor of 2. Excluding granitic terrains, the most spatially extensive dose rates (>50 nGy h −1 ) are found in association with the Mercia Mudstone Group (Triassic argillaceous mudstones) of eastern England. Geological associations between high dose rate and high radon values are also noted. Recent studies of the datasets have revealed the extent of source rock (i.e. bedrock) flux attenuation by soil moisture in conjunction with the density and porosity of the temperate latitude soils found in the UK. The presence or absence of soil cover (and associated presence or absence of attenuation) appears to account for a range of localised variations in the exposure levels encountered. The hypothesis is supported by a study of an extensive combined data set of dose rates obtained from soil sampling and by airborne geophysical survey. With no attenuation factors applied, except those intrinsic to the airborne estimates, a bias to high values of between 10 and 15 nGy h −1 is observed in the soil data. A wide range of

  15. Estimated dose to man from uranium milling via the terrestrial food-chain pathway

    Energy Technology Data Exchange (ETDEWEB)

    Rayno, D.R.

    1982-01-01

    One of the major pathways of radiological exposure to man from uranium milling operations is through the terrestrial food chain. Studies by various investigators have shown the extent of uptake and distribution of U-238, U-234, Th-230, Ra-226, Pb-210, and Po-210 in plants and animals. These long-lived natural radioisotopes, all nuclides of the uranium decay series, are found in concentrated amounts in uranium mill tailings. Data from these investigations are used to estimate the dose to man from consumption of beef and milk contaminated by the tailings. This dose estimate from this technologically enhanced source is compared with that from average normal dietary intake of these radionuclides from natural sources.

  16. Estimated dose to man from uranium milling via the terrestrial food-chain pathway

    International Nuclear Information System (INIS)

    Rayno, D.R.

    1982-01-01

    One of the major pathways of radiological exposure to man from uranium milling operations is through the terrestrial food chain. Studies by various investigators have shown the extent of uptake and distribution of U-238, U-234, Th-230, Ra-226, Pb-210, and Po-210 in plants and animals. These long-lived natural radioisotopes, all nuclides of the uranium decay series, are found in concentrated amounts in uranium mill tailings. Data from these investigations are used to estimate the dose to man from consumption of beef and milk contaminated by the tailings. This dose estimate from this technologically enhanced source is compared with that from average normal dietary intake of these radionuclides from natural sources

  17. Radiation Dose Assesment And Risk Estimation During Extracorporeal Shock Wave Lithotripsy

    International Nuclear Information System (INIS)

    Sulieman, A.; Ibrahim, A.A.; Osman, H.; Yousef, M.

    2011-01-01

    Extracorporeal shockwave lithotripsy (ESWL) is considered the gold standard for calculi fragmentation. The aims of this study are to measure the entrance surface dose (ESD) using thermo-luminescence dosimeter (TLDs) and to estimate the probability of carcinogenesis during ESWL procedure. The study was carried out at two centers (Group A, 50 patients) and (Group B, 25 patients). The mean ESD and effective doses were 36 mGy and 34 mSv. The results show that the probability of carcinogenesis is a tiny value 100 per million patients) but the main biological effect is occurring due to the accumulative impact of radiation.

  18. Infant doses from the transfer of radionuclides in mothers' milk

    International Nuclear Information System (INIS)

    Harrison, J.D.; Smith, T.J.; Phipps, A.W.

    2003-01-01

    Assessments of potential internal exposures of the child following radionuclide intakes by the mother require consideration of transfers during lactation as well as during pregnancy. Current ICRP work on internal dosimetry includes the estimation of radiation doses to newborn infants from radionuclides ingested in mothers' milk. Infant doses will be calculated for maternal intakes by ingestion or inhalation of the radionuclides, radioisotopes of 31 elements, for which fetal dose coefficients have been published. In this paper, modelling approaches are examined, concentrating on models developed for iodine, caesium, polonium, alkaline earth elements and the actinides. Comparisons of model predictions show maximum overall transfer to milk following maternal ingestion during lactation of about 30% of ingested activity for 131 I, 20% for 45 Ca and 137 Cs, 10% for 90 Sr, 1% for 210 Po and low values of less than 0.01% for 239 Pu and 241 Am. The corresponding infant doses from milk consumption are estimated in preliminary calculations to be about two to three times the adult dose for 45 Ca and 131 I, 70-80% of the adult dose for 90 Sr, about 40% for 137 Cs, 20% for 210 Po, and 239 Pu and 241 Am. Infant doses from radionuclides in breast milk are compared with doses to the offspring resulting from in utero exposures during pregnancy. (author)

  19. Radiation doses and possible radiation effects of low-level, chronic radiation in vegetation

    International Nuclear Information System (INIS)

    Rhoads, W.A.; Franks, L.A.

    1975-01-01

    Measurements were made of radiation doses in soil and vegetation in Pu-contaminated areas at the Nevada Test Site with the objective of investigating low-level, low-energy gamma radiation (with some beta radiation) effects at the cytological or morphological level in native shrubs. In this preliminary investigation, the exposure doses to shrubs at the approximate height of stem apical meristems were estimated from 35 to 140 R for a ten-year period. The gamma exposure dose estimated for the same period was 20.7 percent +- 6.4 percent of that recorded by the dosimeters used in several kinds of field instrument surveys. Hence, a survey instrument reading made at about 25 cm in the tops of shrubs should indicate about 1 / 5 the dosimeter-measured exposures. No cytology has yet been undertaken because of the drought since last winter. (auth)

  20. Conclusion of the Preliminary Safety report for the LILW Repository on Trgovska Gora

    International Nuclear Information System (INIS)

    Lokner, V.; Levanat, I.; Schaller, A.; Kucar-Dragicevic, S.; Cerskov Klika, M.; Subasic, D.

    2002-01-01

    For more than a decade, APO d.o.o. has been engaged in preparations which might lead to establishment of a radioactive waste repository on Trgovska Gora, suitable for disposal of low and intermediate level waste (LILW) from the nuclear power plant Krsko. A recent product of theses activities is the preliminary safety assessment report (PSAR) for the proposed repository. In addition to an extensive overview of the repository project status, this preliminary SAR describes how the safety assessment methodology is used to demonstrate that a LILW facility will comply with radiological protection and safety requirements after the repository closure. LILW repository is designed to isolate waste from the environment for a couple hundred years in a reasonably efficient manner. It is generally not practicable to grant full waste containment throughout that period, because it suffices to demonstrate that radionuclide release and migration will remain below acceptable levels, which is achieved through safety assessment scenarios, modeling and calculations. However, with very limited repository specific data, safety assessment can only produce a conservative estimate of the upper bounds of potential exposures the repository could inflict. This PSAR arrives at such estimates in two different ways: (a) by simple bounding calculations and (b) through more sophisticated modeling and application of dedicated computer codes, but with similar conservative assumptions. Both approaches conservatively estimate that the highest potential dose to a nearby resident cannot significantly exceed the dose constraint of 0.2 mSv per year. Only in case of inadvertent intrusion into the near-surface disposal vault, much higher doses might be inflicted immediately after the planned institutional control of 250 years expires, but that can be prevented by a longer control period. Despite the preliminary and bounding style of the calculations, the PSAR has identified most important assumptions and

  1. Estimation of equivalent dose on the ends of hemodynamic physicians during neurological procedures

    International Nuclear Information System (INIS)

    Squair, Peterson L.; Souza, Luiz C. de; Oliveira, Paulo Marcio C. de

    2005-01-01

    The estimation of doses in the hands of physicists during hemodynamic procedures is important to verify the application of radiation protection related to the optimization and limit of dose, principles required by the Portaria 453/98 of Ministry of Health/ANVISA, Brazil. It was checked the levels of exposure of the hands of doctors during the use of the equipment in hemodynamic neurological procedures through dosimetric rings with thermoluminescent dosemeters detectors of LiF: Mg, Ti (TLD-100), calibrated in personal Dose equivalent HP (0.07). The average equivalent dose in the end obtained was 41.12. μSv per scan with an expanded uncertainty of 20% for k = 2. This value is relative to the hemodynamic Neurology procedure using radiological protection procedures accessible to minimize the dose

  2. Rat skin carcinogenesis as a basis for estimating risks at low doses and dose rates of various types of radiation

    International Nuclear Information System (INIS)

    Burns, F.J.; Vanderlaan, M.; Strickland, P.; Albert, R.E.

    1976-01-01

    The recovery rate, age dependence and latent period for tumor induction in rat skin were measured for single and split doses of radiation, and the data were analyzed in terms of a general model in an attempt to estimate the expected tumor response for various types of radiation given at low dose rates for long periods of time. The dorsal skin of male rats was exposed to electrons, x rays, or protons in either single or split doses for several doses and the tumor responses were compared during 80 weeks of observation. A two stage model incorporating a reversible or recoverable mode was developed and various parameters in the model, including recovery rate, dose-response coefficients, and indices of age sensitivity, were evaluated experimentally. The measured parameters were then utilized to calculate expected tumor responses for exposure periods extending for duration of life. The calculations indicated that low dose rates could be markedly ( 1 / 100 to 1 / 1000 ) less effective in producing tumors than the same dose given in a short or acute exposure, although the magnitude of the reduction in effectiveness declines as the dose declines

  3. Answers to questions about updated estimates of occupational radiation doses at Three Mile Island, Unit 2

    International Nuclear Information System (INIS)

    1983-12-01

    The purpose of this question and answer report is to provide a clear, easy-to-understand explanation of revised radiation dose estimates which workers are likely to receive over the course of the cleanup at Three Mile Island, Unit 2, and of the possible health consequences to workers of these new estimates. We will focus primarily on occupational dose, although pertinent questions about public health and safety will also be answered

  4. FN-curves: preliminary estimation of severe accident risks after Fukushima

    International Nuclear Information System (INIS)

    Vasconcelos, Vanderley de; Soares, Wellington Antonio; Costa, Antonio Carlos Lopes da

    2015-01-01

    Doubts of whether the risks related to severe accidents in nuclear reactors are indeed very low were raised after the nuclear accident at Fukushima Daiichi in 2011. Risk estimations of severe accidents in nuclear power plants involve both probability and consequence assessment of such events. Among the ways to display risks, risk curves are tools that express the frequency of exceeding a certain magnitude of consequence. Societal risk is often represented graphically in a FN-curve, a type of risk curve, which displays the probability of having N or more fatalities per year, as a function of N, on a double logarithmic scale. The FN-curve, originally introduced for the assessment of the risks in the nuclear industry through the U.S.NRC Reactor Safety Study WASH-1400 (1975), is used in various countries to express and limit risks of hazardous activities. This first study estimated an expected rate of core damage equal to 5x10 -5 by reactor-year and suggested an upper bound of 3x10 -4 by reactor-year. A more recent report issued by Electric Power Research Institute - EPRI (2008) estimates a figure of the order of 2x10 -5 by reactor-year. The Fukushima nuclear accident apparently implies that the observed core damage frequency is higher than that predicted by these probabilistic safety assessments. Therefore, this paper presents a preliminary analyses of the FN-curves related to severe nuclear reactor accidents, taking into account a combination of available data of past accidents, probability modelling to estimate frequencies, and expert judgments. (author)

  5. FN-curves: preliminary estimation of severe accident risks after Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Vanderley de; Soares, Wellington Antonio; Costa, Antonio Carlos Lopes da, E-mail: vasconv@cdtn.br, E-mail: soaresw@cdtn.br, E-mail: aclc@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Doubts of whether the risks related to severe accidents in nuclear reactors are indeed very low were raised after the nuclear accident at Fukushima Daiichi in 2011. Risk estimations of severe accidents in nuclear power plants involve both probability and consequence assessment of such events. Among the ways to display risks, risk curves are tools that express the frequency of exceeding a certain magnitude of consequence. Societal risk is often represented graphically in a FN-curve, a type of risk curve, which displays the probability of having N or more fatalities per year, as a function of N, on a double logarithmic scale. The FN-curve, originally introduced for the assessment of the risks in the nuclear industry through the U.S.NRC Reactor Safety Study WASH-1400 (1975), is used in various countries to express and limit risks of hazardous activities. This first study estimated an expected rate of core damage equal to 5x10{sup -5} by reactor-year and suggested an upper bound of 3x10{sup -4} by reactor-year. A more recent report issued by Electric Power Research Institute - EPRI (2008) estimates a figure of the order of 2x10{sup -5} by reactor-year. The Fukushima nuclear accident apparently implies that the observed core damage frequency is higher than that predicted by these probabilistic safety assessments. Therefore, this paper presents a preliminary analyses of the FN-curves related to severe nuclear reactor accidents, taking into account a combination of available data of past accidents, probability modelling to estimate frequencies, and expert judgments. (author)

  6. The study of influence of relevant physical parameters variations on the estimates of the effective doses of Rn-222

    International Nuclear Information System (INIS)

    Ridzikova, A.; Fronka, A.; Moucka, L.

    2004-01-01

    Based on the analysis of 12 weekly continuous measurements and 4 integral measurements performed in different seasons in actual apartment rooms, bedrooms in particular, we attempted to identify the uncertainties that are involved in the estimation of radiation doses to lung tissues. We found that the parameters of time of residence, concentration, and equilibrium factor can affect substantially the estimate of the overall early effective dose. The weekly averaged concentration measured in one term is not sufficient for a fairly accurate estimate; actually, the equilibrium factor f must also be known and the actual real individual time of residence must be estimated if we want to adopt this approach to the dose estimation

  7. Estimating Radiological Doses to Predators Foraging in a Low-Level Radioactive Waste Management Area

    International Nuclear Information System (INIS)

    L.Soholt; G.Gonzales; P.Fresquez; K.Bennett; E.Lopez

    2003-01-01

    Since 1957, Los Alamos National Laboratory has operated Area G as its low-level, solid radioactive waste management and disposal area. Although the waste management area is developed, plants, small mammals, and avian and mammalian predators still occupy the less disturbed and revegetated portions of the land. For almost a decade, we have monitored the concentrations of selected radionuclides in soils, plants, and small mammals at Area G. The radionuclides tritium, plutonium-238, and plutonium-239 are regularly found at levels above regional background in all three media. Based on radionuclide concentrations in mice collected from 1994 to 1999, we calculated doses to higher trophic levels (owl, hawk, kestrel, and coyote) that forage on the waste management area. These predators play important functions in the regional ecosystems and are an important part of local Native American traditional tales that identify the uniqueness of their culture. The estimated doses are compared to Department of Energy's interim limit of 0.1 rad/day for the protection of terrestrial wildlife. We used exposure parameters that were derived from the literature for each receptor, including Environmental Protection Agency's exposure factors handbook. Estimated doses to predators ranged from 9E-06 to 2E-04 rad/day, assuming that they forage entirely on the waste management area. These doses are greater than those calculated for predators foraging exclusively in reference areas, but are still well below the interim dose limit. We believe that these calculated doses represent upper-bound estimates of exposure for local predators because the larger predators forage over areas that are much greater than the 63-acre waste management area. Based on these results, we concluded that predators foraging on this area do not face a hazard from radiological exposure under current site conditions

  8. Estimation of background radiation doses for the Peninsular Malaysia's population by ESR dosimetry of tooth enamel.

    Science.gov (United States)

    Rodzi, Mohd; Zhumadilov, Kassym; Ohtaki, Megu; Ivannikov, Alexander; Bhattacharjee, Deborshi; Fukumura, Akifumi; Hoshi, Masaharu

    2011-08-01

    Background radiation dose is used in dosimetry for estimating occupational doses of radiation workers or determining radiation dose of an individual following accidental exposure. In the present study, the absorbed dose and the background radiation level are determined using the electron spin resonance (ESR) method on tooth samples. The effect of using different tooth surfaces and teeth exposed with single medical X-rays on the absorbed dose are also evaluated. A total of 48 molars of position 6-8 were collected from 13 district hospitals in Peninsular Malaysia. Thirty-six teeth had not been exposed to any excessive radiation, and 12 teeth had been directly exposed to a single X-ray dose during medical treatment prior to extraction. There was no significant effect of tooth surfaces and exposure with single X-rays on the measured absorbed dose of an individual. The mean measured absorbed dose of the population is 34 ± 6.2 mGy, with an average tooth enamel age of 39 years. From the slope of a regression line, the estimated annual background dose for Peninsular Malaysia is 0.6 ± 0.3 mGy y(-1). This value is slightly lower than the yearly background dose for Malaysia, and the radiation background dose is established by ESR tooth measurements on samples from India and Russia.

  9. Maximum likelihood estimation of dose-response parameters for therapeutic operating characteristic (TOC) analysis of carcinoma of the nasopharynx

    International Nuclear Information System (INIS)

    Metz, C.E.; Tokars, R.P.; Kronman, H.B.; Griem, M.L.

    1982-01-01

    A Therapeutic Operating Characteristic (TOC) curve for radiation therapy plots, for all possible treatment doses, the probability of tumor ablation as a function of the probability of radiation-induced complication. Application of this analysis to actual therapeutic situation requires that dose-response curves for ablation and for complication be estimated from clinical data. We describe an approach in which ''maximum likelihood estimates'' of these dose-response curves are made, and we apply this approach to data collected on responses to radiotherapy for carcinoma of the nasopharynx. TOC curves constructed from the estimated dose-response curves are subject to moderately large uncertainties because of the limitations of available data.These TOC curves suggest, however, that treatment doses greater than 1800 rem may substantially increase the probability of tumor ablation with little increase in the risk of radiation-induced cervical myelopathy, especially for T1 and T2 tumors

  10. Application of Boosting Regression Trees to Preliminary Cost Estimation in Building Construction Projects

    Directory of Open Access Journals (Sweden)

    Yoonseok Shin

    2015-01-01

    Full Text Available Among the recent data mining techniques available, the boosting approach has attracted a great deal of attention because of its effective learning algorithm and strong boundaries in terms of its generalization performance. However, the boosting approach has yet to be used in regression problems within the construction domain, including cost estimations, but has been actively utilized in other domains. Therefore, a boosting regression tree (BRT is applied to cost estimations at the early stage of a construction project to examine the applicability of the boosting approach to a regression problem within the construction domain. To evaluate the performance of the BRT model, its performance was compared with that of a neural network (NN model, which has been proven to have a high performance in cost estimation domains. The BRT model has shown results similar to those of NN model using 234 actual cost datasets of a building construction project. In addition, the BRT model can provide additional information such as the importance plot and structure model, which can support estimators in comprehending the decision making process. Consequently, the boosting approach has potential applicability in preliminary cost estimations in a building construction project.

  11. FY 1992 task plans for the Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    1991-10-01

    Phase 1 of the HEDR Project was designed to develop and demonstrate a method for estimating radiation doses people may have received from Hanford Site operations since 1944. The method researchers developed relied on a variety of measured and reconstructed data as input to a modular computer model that generates dose estimates and their uncertainties. As part of Phase 1, researchers used the reconstructed data and computer model to calculate preliminary dose estimates for populations from limited radionuclides, in a limited geographical area and time period. Phase 1 ended in FY 1990. In February 1991, the TSP decided to shift the project planning approach away from phases--which were centered around completion of major portions of technical activities--to individual fiscal years (FYs), which span October of one year through September of the next. Therefore, activities that were previously designated to occur in phases are now designated in an integrated schedule to occur in one or more of the next fiscal years into FY 1995. Task plans are updated every 6 months. In FY 1992, scientists will continue to improve Phase 1 data and models to calculate more accurate and precise dose estimates. The plan for FY 1992 has been prepared based on activities and budgets approved by the Technical Steering Panel (TSP) at its meeting on August 19--20, 1991. The activities can be divided into four categories: (1) model and data evaluation activities, (2) additional dose estimates, (3) model and data development activities, and (4) technical and communication support. 3 figs., 2 tabs

  12. Preliminary Estimation of Kappa Parameter in Croatia

    Science.gov (United States)

    Stanko, Davor; Markušić, Snježana; Ivančić, Ines; Mario, Gazdek; Gülerce, Zeynep

    2017-12-01

    Spectral parameter kappa κ is used to describe spectral amplitude decay “crash syndrome” at high frequencies. The purpose of this research is to estimate spectral parameter kappa for the first time in Croatia based on small and moderate earthquakes. Recordings of local earthquakes with magnitudes higher than 3, epicentre distances less than 150 km, and focal depths less than 30 km from seismological stations in Croatia are used. The value of kappa was estimated from the acceleration amplitude spectrum of shear waves from the slope of the high-frequency part where the spectrum starts to decay rapidly to a noise floor. Kappa models as a function of a site and distance were derived from a standard linear regression of kappa-distance dependence. Site kappa was determined from the extrapolation of the regression line to a zero distance. The preliminary results of site kappa across Croatia are promising. In this research, these results are compared with local site condition parameters for each station, e.g. shear wave velocity in the upper 30 m from geophysical measurements and with existing global shear wave velocity - site kappa values. Spatial distribution of individual kappa’s is compared with the azimuthal distribution of earthquake epicentres. These results are significant for a couple of reasons: to extend the knowledge of the attenuation of near-surface crust layers of the Dinarides and to provide additional information on the local earthquake parameters for updating seismic hazard maps of studied area. Site kappa can be used in the re-creation, and re-calibration of attenuation of peak horizontal and/or vertical acceleration in the Dinarides area since information on the local site conditions were not included in the previous studies.

  13. Development of a head simulator for exposure dose estimation on patients exposed by odontological X-rays

    International Nuclear Information System (INIS)

    Moura Neto, Francisco N.; Batista, Eutropio V.; Santos, Adriano M.

    2009-01-01

    In the obtaining a odontological radiography, the individual is exposed to te radiation and part of that radiation will be absorbed by his organism. The estimative of absorbed dose can be accomplished through calculations where are considered: the distance from the source to the individual, the energy of the emitted X-ray at the moment of the exposure and the bode region exposed; and as that option does not possess great precision, alternative forms are seek for the quantification such doses. This work proposes the construction of a head simulator to be used in the estimative of absorbed dose in patients, during the accomplishment of the odontological radiographic examinations. As a perspective of work, it is intended to use the phantom to help in the absorbed doses for obtainment of parameters in X-ray odontological devices, contributing of image obtainment with more quality and less radiation dose in the patient

  14. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    International Nuclear Information System (INIS)

    Johnsen, Boel; Fasmer, Kristine Eldevik; Boye, Kjetil; Rosendahl, Karen; Aukland, Stein Magnus; Trovik, Clement; Biermann, Martin

    2017-01-01

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether 18 F-fluorodeoxyglucose positron emission tomography - computed tomography ( 18 F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  15. DEMO maintenance scenarios: scheme for time estimations and preliminary estimates for blankets arranged in multi-module-segments

    International Nuclear Information System (INIS)

    Nagy, D.

    2007-01-01

    Previous conceptual studies made clear that the ITER blanket concept and segmentation is not suitable for the environment of a potential fusion power plant (DEMO). One promising concept to be used instead is the so-called Multi-Module-Segment (MMS) concept. Each MMS consists of a number of blankets arranged on a strong back plate thus forming ''banana'' shaped in-board (IB) and out-board (OB) segments. With respect to port size, weight, or other limiting aspects the IB and OB MMS are segmented in toroidal direction. The number of segments to be replaced would be below 100. For this segmentation concept a new maintenance scenario had to be worked out. The aim of this paper is to present a promising MMS maintenance scenario, a flexible scheme for time estimations under varying boundary conditions and preliminary time estimates. According to the proposed scenario two upper, vertical arranged maintenance ports have to be opened for blanket maintenance on opposite sides of the tokamak. Both ports are central to a 180 degree sector and the MMS are removed and inserted through both ports. In-vessel machines are operating to transport the elements in toroidal direction and also to insert and attach the MMS to the shield. Outside the vessel the elements have to be transported between the tokamak and the hot cell to be refurbished. Calculating the maintenance time for such a scenario is rather challenging due to the numerous parallel processes involved. For this reason a flexible, multi-level calculation scheme has been developed in which the operations are organized into three levels: At the lowest level the basic maintenance steps are determined. These are organized into maintenance sequences that take into account parallelisms in the system. Several maintenance sequences constitute the maintenance phases which correspond to a certain logistics scenario. By adding the required times of the maintenance phases the total maintenance time is obtained. The paper presents

  16. Radiation doses from computed tomography in Australia

    International Nuclear Information System (INIS)

    Thomson, J.E.M.; Tingey, D.R.C.

    1996-01-01

    Recent surveys in the UK and New Zealand have shown that although the number of CT examinations small compared to conventional Radiology, CT contributes about 20% to the overall dose from diagnostic radiology. In view of these findings and the rapid increase in the number of CT facilities in recent years, a survey of the number of facilities, frequency of examination, techniques and patient doses has been performed. Australia, with 329 units is well endowed with CT equipment compared to European Countries and New Zealand. For many examinations a wide range was found in the number of slices and slice widths used and this led to a large spread in the corresponding doses. Assuming the practices of the non-responders are statistically similar to those who responded, some preliminary estimates of population doses can be made. There could be as many as 1.1 million CT examinations each year in Australia resulting in a per capur effectie dose of 0.36 mSv. Although the results of this survey are still subject to some refinement, they indicate that CT is a major, and possibly the dominant, contributor to doses from diagnostic radiology in Australia. (author)

  17. Automating and estimating glomerular filtration rate for dosing medications and staging chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Trinkley KE

    2014-05-01

    Full Text Available Katy E Trinkley,1 S Michelle Nikels,2 Robert L Page II,1 Melanie S Joy11Skaggs School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, University of Colorado, Aurora, CO, USA Objective: The purpose of this paper is to serve as a review for primary care providers on the bedside methods for estimating glomerular filtration rate (GFR for dosing and chronic kidney disease (CKD staging and to discuss how automated health information technologies (HIT can enhance clinical documentation of staging and reduce medication errors in patients with CKD.Methods: A nonsystematic search of PubMed (through March 2013 was conducted to determine the optimal approach to estimate GFR for dosing and CKD staging and to identify examples of how automated HITs can improve health outcomes in patients with CKD. Papers known to the authors were included, as were scientific statements. Articles were chosen based on the judgment of the authors.Results: Drug-dosing decisions should be based on the method used in the published studies and package labeling that have been determined to be safe, which is most often the Cockcroft–Gault formula unadjusted for body weight. Although Modification of Diet in Renal Disease is more commonly used in practice for staging, the CKD–Epidemiology Collaboration (CKD–EPI equation is the most accurate formula for estimating the CKD staging, especially at higher GFR values. Automated HITs offer a solution to the complexity of determining which equation to use for a given clinical scenario. HITs can educate providers on which formula to use and how to apply the formula in a given clinical situation, ultimately improving appropriate medication and medical management in CKD patients.Conclusion: Appropriate estimation of GFR is key to optimal health outcomes. HITs assist clinicians in both choosing the most appropriate GFR estimation formula and in applying the results of the GFR estimation in practice. Key limitations of the

  18. Dose estimative in operators during petroleum wells logging with nuclear wireless probes through computer modelling

    International Nuclear Information System (INIS)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo T.; Correa, Samanda Cristine Arruda; Rocha, Paula L.F.

    2011-01-01

    This paper evaluates the absorbed dose and the effective dose on operators during the petroleum well logging with nuclear wireless that uses gamma radiation sources. To obtain the data, a typical scenery of a logging procedure will be simulated with MCNPX Monte Carlo code. The simulated logging probe was the Density Gamma Probe - TRISOND produced by Robertson Geolloging. The absorbed dose values were estimated through the anthropomorphic simulator in male voxel MAX. The effective dose values were obtained using the ICRP 103

  19. Estimation of outdoor and indoor effective dose and excess lifetime cancer risk from Gamma dose rates in Gonabad, Iran

    Energy Technology Data Exchange (ETDEWEB)

    Jafaria, R.; Zarghania, H.; Mohammadia, A., E-mail: rvzreza@gmail.com [Paramedical faculty, Birjand University of Medical Sciences, Birjand (Iran, Islamic Republic of)

    2017-07-01

    Background gamma irradiation in the indoor and outdoor environments is a major concern in the world. The study area was Gonabad city. Three stations and buildings for background radiation measurement of outdoor and indoor were randomly selected and the Geiger-Muller detector (X5C plus) was used. All dose rates on display of survey meter were recorded and mean of all data in each station and buildings was computed and taken as measured dose rate of that particular station. The average dose rates of background radiation were 84.2 nSv/h for outdoor and 108.6 nSv/h for indoor, maximum and minimum dose rates were 88.9 nSv/h and 77.7 nSv/h for outdoor measurements and 125.4 nSv/h and 94.1 nSv/h for indoor measurements, respectively. Results show that the annual effective dose is 0.64 mSv, which compare to global level of the annual effective dose 0.48 mSv is high. Estimated excess lifetime cancer risk was 2.24×10{sup -3} , indicated that it is large compared to the world average value of 0.25×10{sup -3}. (author)

  20. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  1. 3D conditional generative adversarial networks for high-quality PET image estimation at low dose.

    Science.gov (United States)

    Wang, Yan; Yu, Biting; Wang, Lei; Zu, Chen; Lalush, David S; Lin, Weili; Wu, Xi; Zhou, Jiliu; Shen, Dinggang; Zhou, Luping

    2018-07-01

    Positron emission tomography (PET) is a widely used imaging modality, providing insight into both the biochemical and physiological processes of human body. Usually, a full dose radioactive tracer is required to obtain high-quality PET images for clinical needs. This inevitably raises concerns about potential health hazards. On the other hand, dose reduction may cause the increased noise in the reconstructed PET images, which impacts the image quality to a certain extent. In this paper, in order to reduce the radiation exposure while maintaining the high quality of PET images, we propose a novel method based on 3D conditional generative adversarial networks (3D c-GANs) to estimate the high-quality full-dose PET images from low-dose ones. Generative adversarial networks (GANs) include a generator network and a discriminator network which are trained simultaneously with the goal of one beating the other. Similar to GANs, in the proposed 3D c-GANs, we condition the model on an input low-dose PET image and generate a corresponding output full-dose PET image. Specifically, to render the same underlying information between the low-dose and full-dose PET images, a 3D U-net-like deep architecture which can combine hierarchical features by using skip connection is designed as the generator network to synthesize the full-dose image. In order to guarantee the synthesized PET image to be close to the real one, we take into account of the estimation error loss in addition to the discriminator feedback to train the generator network. Furthermore, a concatenated 3D c-GANs based progressive refinement scheme is also proposed to further improve the quality of estimated images. Validation was done on a real human brain dataset including both the normal subjects and the subjects diagnosed as mild cognitive impairment (MCI). Experimental results show that our proposed 3D c-GANs method outperforms the benchmark methods and achieves much better performance than the state

  2. Preliminary Results of Clover and Grass Coverage and Total Dry Matter Estimation in Clover-Grass Crops Using Image Analysis

    Directory of Open Access Journals (Sweden)

    Anders K. Mortensen

    2017-12-01

    Full Text Available The clover-grass ratio is an important factor in composing feed ratios for livestock. Cameras in the field allow the user to estimate the clover-grass ratio using image analysis; however, current methods assume the total dry matter is known. This paper presents the preliminary results of an image analysis method for non-destructively estimating the total dry matter of clover-grass. The presented method includes three steps: (1 classification of image illumination using a histogram of the difference in excess green and excess red; (2 segmentation of clover and grass using edge detection and morphology; and (3 estimation of total dry matter using grass coverage derived from the segmentation and climate parameters. The method was developed and evaluated on images captured in a clover-grass plot experiment during the spring growing season. The preliminary results are promising and show a high correlation between the image-based total dry matter estimate and the harvested dry matter ( R 2 = 0.93 with an RMSE of 210 kg ha − 1 .

  3. In-flight dose estimates for aircraft crew and pregnant female crew members in military transport missions

    International Nuclear Information System (INIS)

    Alves, J. G.; Mairos, J. C.

    2007-01-01

    Aircraft fighter pilots may experience risks other than the exposure to cosmic radiation due to the characteristics of a typical fighter flight. The combined risks for fighter pilots due to the G-forces, hypobaric hypoxia, cosmic radiation exposure, etc. have determined that pregnant female pilots should remain on ground. However, several military transport missions can be considered an ordinary civil aircraft flight and the question arises whether a pregnant female crew member could still be part of the aircraft crew. The cosmic radiation dose received was estimated for transport missions carried out on the Hercules C-130 type of aircraft by a single air squad in 1 month. The flights departed from Lisboa to areas such as: the Azores, several countries in central and southern Africa, the eastern coast of the USA and the Balkans, and an estimate of the cosmic radiation dose received on each flight was carried out. A monthly average cosmic radiation dose to the aircraft crew was determined and the dose values obtained were discussed in relation to the limits established by the European Union Council Directive 96/29/Euratom. The cosmic radiation dose estimates were performed using the EPCARD v3.2 and the CARI-6 computing codes. EPCARD v3.2 was kindly made available by GSF-National Research Centre for Environment and Health, Inst. of Radiation Protection (Neuherberg (Germany)). CARI-6 (version July 7, 2004) was downloaded from the web site of the Civil Aerospace Medical Inst., Federal Aviation Administration (USA). In this study an estimate of the cosmic radiation dose received by military aircraft crew on typical transport missions is made. (authors)

  4. Development of internal dose calculation model and the data base updated IDES (Internal Dose Estimation System)

    International Nuclear Information System (INIS)

    Hongo, Shozo; Yamaguchi, Hiroshi; Takeshita, Hiroshi; Iwai, Satoshi.

    1994-01-01

    A computer program named IDES is developed by BASIC language for a personal computer and translated to C language of engineering work station. The IDES carries out internal dose calculations described in ICRP Publication 30 and it installs the program of transformation method which is an empirical method to estimate absorbed fractions of different physiques from ICRP Referenceman. The program consists of three tasks: productions of SAF for Japanese including children, productions of SEE, Specific Effective Energy, and calculation of effective dose equivalents. Each task and corresponding data file appear as a module so as to meet future requirement for revisions of the related data. Usefulness of IDES is discussed by exemplifying the case that 5 age groups of Japanese intake orally Co-60 or Mn-54. (author)

  5. Dose estimation and prediction of radiation effects on aquatic biota resulting from radioactive releases from the nuclear fuel cycle

    International Nuclear Information System (INIS)

    Blaylock, B.G.; Witherspoon, J.P.

    1975-01-01

    Aquatic organisms are exposed to radionuclides released to the environment during various steps of the nuclear fuel cycle. Routine releases from these processes are limited in compliance with technical specifications and requirements of federal regulations. These regulations reflect I.C.R.P. recommendations which are designed to provide an environment considered safe for man. It is generally accepted that aquatic organisms will not receive damaging external radiation doses in such environments; however, because of possible bioaccumulation of radionuclides there is concern that aquatic organisms might be adversely affected by internal doses. The objectives of this paper are: to estimate the radiation dose received by aquatic biota from the different processes and determine the major dose-contributing radionuclides, and to assess the impact of estimated doses on aquatic biota. Dose estimates are made by using radionuclide concentration measured in the liquid effluents of representative facilities. This evaluation indicates the potential for the greatest radiation dose to aquatic biota from the nuclear fuel supply facilities (i.e., uranium mining and milling). The effects of chronic low-level radiation on aquatic organisms are discussed from somatic and genetic viewpoints. Based on the body of radiobiological evidence accumulated up to the present time, no significant deleterious effects are predicted for populations of aquatic organisms exposed to the estimated dose rates resulting from routine releases from conversion, enrichment, fabrication, reactors and reprocessing facilities. At the doses estimated for milling and mining operations it would be difficult to detect radiation effects on aquatic populations; however, the significance of such radiation exposures to aquatic populations cannot be fully evaluated without further research on effects of chronic low-level radiation. (U.S.)

  6. Improved dose-volume histogram estimates for radiopharmaceutical therapy by optimizing quantitative SPECT reconstruction parameters

    Science.gov (United States)

    Cheng, Lishui; Hobbs, Robert F.; Segars, Paul W.; Sgouros, George; Frey, Eric C.

    2013-06-01

    In radiopharmaceutical therapy, an understanding of the dose distribution in normal and target tissues is important for optimizing treatment. Three-dimensional (3D) dosimetry takes into account patient anatomy and the nonuniform uptake of radiopharmaceuticals in tissues. Dose-volume histograms (DVHs) provide a useful summary representation of the 3D dose distribution and have been widely used for external beam treatment planning. Reliable 3D dosimetry requires an accurate 3D radioactivity distribution as the input. However, activity distribution estimates from SPECT are corrupted by noise and partial volume effects (PVEs). In this work, we systematically investigated OS-EM based quantitative SPECT (QSPECT) image reconstruction in terms of its effect on DVHs estimates. A modified 3D NURBS-based Cardiac-Torso (NCAT) phantom that incorporated a non-uniform kidney model and clinically realistic organ activities and biokinetics was used. Projections were generated using a Monte Carlo (MC) simulation; noise effects were studied using 50 noise realizations with clinical count levels. Activity images were reconstructed using QSPECT with compensation for attenuation, scatter and collimator-detector response (CDR). Dose rate distributions were estimated by convolution of the activity image with a voxel S kernel. Cumulative DVHs were calculated from the phantom and QSPECT images and compared both qualitatively and quantitatively. We found that noise, PVEs, and ringing artifacts due to CDR compensation all degraded histogram estimates. Low-pass filtering and early termination of the iterative process were needed to reduce the effects of noise and ringing artifacts on DVHs, but resulted in increased degradations due to PVEs. Large objects with few features, such as the liver, had more accurate histogram estimates and required fewer iterations and more smoothing for optimal results. Smaller objects with fine details, such as the kidneys, required more iterations and less

  7. Estimation of Exposure Doses for Several Scenarios of the Landfill Disposal of NORM Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Ko, Nak Yul; Baik, Min Hoon [KAERI, Daejeon (Korea, Republic of); Yoon, Ki Hoon [Korea Institude of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-05-15

    The Act on safety control of radioactive materials around living environment was promulgated to protect citizen's health and environment in 2013. According to this Act, the integrated plan for radiation protection and the necessary safety guides for treatment, reuse, and disposal of NORM wastes have to be made. And NORM wastes have to be disposed in landfill sites by reducing the concentration of radionuclide, and they should not be reutilized. In this study, we estimated exposure doses for several scenarios for NORM (Naturally Occurring Radioactive Materials) waste disposal into a reference landfill site to check the radiological safety. Also, we estimated the amount of NORM wastes for different activity levels of important radionuclides in wastes to be disposed into a landfill site based on the exposure dose limits to support the establishment of technical bases for safety guide. We estimated the amount of NORM wastes for different activity levels of wastes containing U series, Th series, and {sup 40}K based on the exposure dose limits. The results of this study can be used as technical bases to support the establishment of a guide for the safe management of NORM waste disposal.

  8. Radiation dose and cancer risk estimates in helical CT for pulmonary tuberculosis infections

    Directory of Open Access Journals (Sweden)

    Adeleye Bamise

    2017-12-01

    Full Text Available The preference for computed tomography (CT for the clinical assessment of pulmonary tuberculosis (PTB infections has increased the concern about the potential risk of cancer in exposed patients. In this study, we investigated the correlation between cancer risk and radiation doses from different CT scanners, assuming an equivalent scan protocol. Radiation doses from three 16-slice units were estimated using the CT-Expo dosimetry software version 2.4 and standard CT scan protocol for patients with suspected PTB infections. The lifetime risk of cancer for each scanner was determined using the methodology outlined in the BEIR VII report. Organ doses were significantly different (P < 0.05 between the scanners. The calculated effective dose for scanner H2 is 34% and 37% higher than scanners H3 and H1 respectively. A high and statistically significant correlation was observed between estimated lifetime cancer risk for both male (r2 = 0.943, P < 0.05 and female patients (r2 = 0.989, P < 0.05. The risk variation between the scanners was slightly higher than 2% for all ages but was much smaller for specific ages for male and female patients (0.2% and 0.7%, respectively. These variations provide an indication that the use of a scanner optimizing protocol is imperative.

  9. Radiation dose and cancer risk estimates in helical CT for pulmonary tuberculosis infections

    Science.gov (United States)

    Adeleye, Bamise; Chetty, Naven

    2017-12-01

    The preference for computed tomography (CT) for the clinical assessment of pulmonary tuberculosis (PTB) infections has increased the concern about the potential risk of cancer in exposed patients. In this study, we investigated the correlation between cancer risk and radiation doses from different CT scanners, assuming an equivalent scan protocol. Radiation doses from three 16-slice units were estimated using the CT-Expo dosimetry software version 2.4 and standard CT scan protocol for patients with suspected PTB infections. The lifetime risk of cancer for each scanner was determined using the methodology outlined in the BEIR VII report. Organ doses were significantly different (P < 0.05) between the scanners. The calculated effective dose for scanner H2 is 34% and 37% higher than scanners H3 and H1 respectively. A high and statistically significant correlation was observed between estimated lifetime cancer risk for both male (r2 = 0.943, P < 0.05) and female patients (r2 = 0.989, P < 0.05). The risk variation between the scanners was slightly higher than 2% for all ages but was much smaller for specific ages for male and female patients (0.2% and 0.7%, respectively). These variations provide an indication that the use of a scanner optimizing protocol is imperative.

  10. Monitoring of German Fertility: Estimation of Monthly and Yearly Total Fertility Rates on the Basis of Preliminary Monthly Data

    Directory of Open Access Journals (Sweden)

    Gabriele Doblhammer

    2011-02-01

    Full Text Available This paper introduces a set of methods for estimating fertility indicators in the absence of recent and short-term birth statistics. For Germany, we propose a set of straightforward methods that allow for the computation of monthly and yearly total fertility rates (mTFR on the basis of preliminary monthly data, including a confidence interval. The method for estimating most current fertility rates can be applied when no information on the age structure and the number of women exposed to childbearing is available. The methods introduced in this study are useful for calculating monthly birth indicators, with minimal requirements for data quality and statistical effort. In addition, we suggest an approach for projecting the yearly TFR based on preliminary monthly information up to June.

  11. Comparison of computational models for estimation of whole body and organ radiation dose in rainbow trout from uptake of iodine-131 - Comparison of rainbow trout phantoms for estimation of whole body and organ radiation dose rates from uptake of iodine-131 in freshwater systems

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Nicole E. [Department of Environmental and Engineering Sciences, Clemson University, Clemson, South Carolina, 29634 (United States); Johnson, Thomas E.; Ruedig, Elizabeth; Pinder, John E. III [Department of Environmental and Radiological Health Sciences, Colorado State University, 1681 Campus Delivery, Fort Collins, Colorado, 80523 (United States)

    2014-07-01

    Internal radiation dose rates to biota are typically calculated utilizing dose conversion factors (DCF), which are values for absorbed dose rate per activity concentration (i.e. mGy d{sup -1} per Bq g{sup -1}). The current methodology employed by both the ICRP and within the ERICA Integrated Approach for calculating dose conversion coefficients is to use Monte Carlo modeling of a homogeneously distributed radionuclide within an ellipsoidal phantom chosen to represent a particular organism. It has been shown that for whole-body DCF, homogenous distribution is a reasonable assumption for electrons, and is associated with an uncertainty of less than 30% for photons. However, if a radionuclide has a specific tissue tropism (e.g. iodine-131 in thyroid) a much higher dose will be received by the organ or tissue than by the whole body. Internal organs are modeled generically as spheres within the ellipsoid phantom, due to the complex and variable nature of organ structure and arrangement within different types of organisms. Ratios of whole-body to organ mass offer conservative conversions of whole-body to organ specific DCF (Gomez-Ros et al 2008), but may considerably overestimate the organ dose; more accurate estimates can be made based on specific absorbed fractions and activity concentrations. Establishment of appropriate screening levels in the regulatory paradigm requires incorporation of sufficient knowledge of dose effects; the ICRP currently lists no derived consideration reference levels for organs, meaning that specific risks associated with organ dose rates are unavailable (ICRP 108). Model comparison and refinement is important in the process of determining both dose rates and dose effects, and here we develop and compare three models for rainbow trout (Oncorhynchus mykiss): the simple geometry described above, a more specific geometry employing anatomically relevant organ size and location, and voxel reconstruction of internal anatomy obtained from CT imaging

  12. Estimating effective dose to pediatric patients undergoing interventional radiology procedures using anthropomorphic phantoms and MOSFET dosimeters.

    Science.gov (United States)

    Miksys, Nelson; Gordon, Christopher L; Thomas, Karen; Connolly, Bairbre L

    2010-05-01

    The purpose of this study was to estimate the effective doses received by pediatric patients during interventional radiology procedures and to present those doses in "look-up tables" standardized according to minute of fluoroscopy and frame of digital subtraction angiography (DSA). Organ doses were measured with metal oxide semiconductor field effect transistor (MOSFET) dosimeters inserted within three anthropomorphic phantoms, representing children at ages 1, 5, and 10 years, at locations corresponding to radiosensitive organs. The phantoms were exposed to mock interventional radiology procedures of the head, chest, and abdomen using posteroanterior and lateral geometries, varying magnification, and fluoroscopy or DSA exposures. Effective doses were calculated from organ doses recorded by the MOSFET dosimeters and are presented in look-up tables according to the different age groups. The largest effective dose burden for fluoroscopy was recorded for posteroanterior and lateral abdominal procedures (0.2-1.1 mSv/min of fluoroscopy), whereas procedures of the head resulted in the lowest effective doses (0.02-0.08 mSv/min of fluoroscopy). DSA exposures of the abdomen imparted higher doses (0.02-0.07 mSv/DSA frame) than did those involving the head and chest. Patient doses during interventional procedures vary significantly depending on the type of procedure. User-friendly look-up tables may provide a helpful tool for health care providers in estimating effective doses for an individual procedure.

  13. Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE)

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Oda, Seitaro; Nakaura, Takeshi; Yuki, Hideaki; Hirata, Kenichiro; Namimoto, Tomohiro; Sakabe, Daisuke; Hatemura, Masahiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Honjo, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Honjo, Kumamoto (Japan)

    2017-06-15

    To investigate the usefulness of modifying scanning parameters based on the size-specific dose estimate (SSDE) for a breast-dose reduction for chest CT. We scanned 26 women with a fixed volume CT dose index (CTDI{sub vol}) (15 mGy) and another 26 with a fixed SSDE (15 mGy) protocol (protocol 1 and 2, respectively). In protocol 2, tube current was calculated based on the patient habitus obtained on scout images. We compared the mean breast dose and the inter-patient breast dose variability and performed linear regression analysis of the breast dose and the body mass index (BMI) of the two protocols. The mean breast dose was about 35 % lower under protocol 2 than protocol 1 (10.9 mGy vs. 16.8 mGy, p < 0.01). The inter-patient breast dose variability was significantly lower under protocol 2 than 1 (1.2 mGy vs. 2.5 mGy, p < 0.01). We observed a moderate negative correlation between the breast dose and the BMI under protocol 1 (r = 0.43, p < 0.01); there was no significant correlation (r = 0.06, p = 0.35) under protocol 2. The SSDE-based protocol achieved a reduction in breast dose and in inter-patient breast dose variability. (orig.)

  14. Exploratory shaft facility preliminary designs - Permian Basin

    International Nuclear Information System (INIS)

    1983-09-01

    The purpose of the Preliminary Design Report, Permian Basin, is to provide a description of the preliminary design for an Exploratory Shaft Facility in the Permian Basin, Texas. This issue of the report describes the preliminary design for constructing the exploratory shaft using the Large Hole Drilling method of construction and outlines the preliminary design and estimates of probable construction cost. The Preliminary Design Report is prepared to complement and summarize other documents that comprise the design at the preliminary stage of completion, December 1982. Other design documents include drawings, cost estimates and schedules. The preliminary design drawing package, which includes the construction schedule drawing, depicts the descriptions in this report. For reference, a list of the drawing titles and corresponding numbers are included in the Appendix. The report is divided into three principal sections: Design Basis, Facility Description, and Construction Cost Estimate. 30 references, 13 tables

  15. Dose from Cs-137 ingestion in Italian Region in 1998-1999. A preliminary analysis of the results of a monitoring campaign

    International Nuclear Information System (INIS)

    Bochicchio, F.; Magnoni, M.; Agnesod, G.

    2000-01-01

    A measurement programme started on 1998 in order to assess the committed effective dose for all the Italian Regions due to ingestion of Cs-137. This programme was carried out within the framework of the SICRA network, which is in ad-hoc personal computer network, set up by the Ministry of Health in order to connect the regional laboratories for the control of the environmental radioactivity and the national institutes in order to allow a fast transmission and analysis of radioactivity measurement results. The programme was jointly decided and designed by the following regional and national institutes: the regional laboratories for the control of the environmental radioactivity, most of which are Regional Agencies for the Environmental Protection (ARPA); the National Agency for the Environmental Protection (ANPA); the National Institute for Prevention and Safety in Workplaces (ISPESL), the Italian National Institute of Health (ISS), the Ministry of Environment and the Ministry of Health. The following five major components of the Italian diet, which use expected to significantly contribute to the total ingestion dose, were included in the sampling protocol: milk, meat, pasta, bread, and fish. In most cases the samples were taken in big stores in order to be representative of the local consumption. The sample collection started on October 1998 and continued in 1999. The designed Minimum Detectable Activity was 0.1 Bq/kg. Most of the measured values are below the MDA so that appropriate statistical techniques are used in order to estimate the average activity concentration and dose. Regional data of food consumption are taken from the Italian National Statistic Institute, and dose conversion factor for adults is used. A minimum of 24 samples for the period October-December 1998 was asked to each Region, however, more data were sent by some Regions. Preliminary results of activity concentration measurements on 1249 samples of 1998 are the following: in 439 cases the

  16. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    International Nuclear Information System (INIS)

    Liu, Baochang; Darko, Johnson; Osei, Ernest

    2016-01-01

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D m ) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  17. Poster - 56: Preliminary comparison of FF- and FFF-VMAT for prostate plans with higher rectal dose

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Baochang; Darko, Johnson; Osei, Ernest [Grand River Regional Cancer Centre, Kitchener, Ontario (Canada)

    2016-08-15

    Purpose: A recent retrospective study found 53 patients previously treated to 78Gy/39 using flattened filtered (FF) 6X-VMAT at GRRCC had rectal DVH more than one standard deviation higher than the average. This study was to investigate if using 6FFFor10FFF beams could reduce these DVHs without compromising target coverage. Methods: Twenty patients’ plans were re-planed with 2-arc 6X-VMAT, 6FFF-VMAT and 10FFF-VMAT using the Eclipse TPS following departmental protocol. All plans had the same optimization and normalization, and were evaluated against the acceptance criteria from the QUANTEC and Emami. Statistical differences in the mean dose to OARs (D{sub m}) and PTV homogeneity index (HI) between energies were tested using the paired sample Wilcoxon signed rank statistical method (p<0.05). Beam delivery accuracy was checked on five patients using portal dosimetry (PD). Results: The PTV HI for the 10FFF shows no statistical difference from the 6X. All the OARs, except left femoral head with 6FFF, have significantly lower Dm using 6FFF and 10FFF .There is no difference in the maximum doses to rectum and bladder and are limited by the prescribed doses. Measurements show good agreements in the gamma evaluation (3%/3mm) for all energies. Conclusion: This preliminary study shows that doses to the OARs are reduced using 10FFF for the same target coverage. The plans using 6FFF result in lower doses to some OARs, and statistically different PTV HI. All plans showed very good agreement with measurements.

  18. Estimate of the absorbed dose in the mouse organs and tissues after tritium administration

    International Nuclear Information System (INIS)

    Saito, Masahiro

    2000-01-01

    Chronic and accidental release of tritium from future fusion facilities may cause some extent of hazardous effect to the public health. Various experiments using small animals such as mice have been performed to mimic the dose accumulation due to tritium intake by the human body. An difficulty in such animal experiments using small animals is that it is rather difficult to administer tritium orally and estimate the dose to small organs or tissues. In the course of our study, a simple method to administer THO and T-labeled amino acids orally to the mouse was dictated and dose accumulation in various organs and tissues was determined. The tritium retention in the bone marrow was also determined using the micro-centrifuge method. Throughout our experiment, colony-bred DDY mice were used. The 8-10 week old male mice were orally and intraperitoneally administered THO water or T-amino acids mixture solution. For the purpose of oral administration, a 10 μl aliquot of T-containing saline solution was placed on the tongue of the mice using an automatic micropipette. At various times after tritium administration, the animals were sacrificed and the amount of tritium in various tissues and organs including bone marrow was examined. Dose accumulation pattern after THO intake and T-amino acids was compared between intraperitoneal injection and oral administration. The accumulated dose after oral administration of THO exhibited a tendency to be 10-20% higher than after intraperitoneal injection. The bone marrow dose after oral intake of THO was found to be lower than the doses to urine, blood, liver and testis. In contrast, the blood dose gave a conservative estimate for the dose to the other tissues and organs. (author)

  19. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Wang, Bo

    2008-01-01

    There is a need for an easily accessible method for effective dose estimation in pediatric CT. To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients. A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data. Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10-15 mSv). Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support. (orig.)

  20. Gold nanoparticle-aided brachytherapy with vascular dose painting: estimation of dose enhancement to the tumor endothelial cell nucleus.

    Science.gov (United States)

    Ngwa, Wilfred; Makrigiorgos, G Mike; Berbeco, Ross I

    2012-01-01

    Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. A tumor vascular endothelial cell (EC) is modeled as a slab of 2 μm (thickness) × 10 μm (length) × 10 μm (width). The EC contains a nucleus of 5 μm diameter and thickness of 0.5-1 μm, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting extensive tumor cell death.

  1. Gold nanoparticle-aided brachytherapy with vascular dose painting: Estimation of dose enhancement to the tumor endothelial cell nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Makrigiorgos, G. Mike; Berbeco, Ross I. [Department of Radiation Oncology, Division of Medical Physics and Biophysics, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2012-01-15

    Purpose: Theoretical microdosimetry at the subcellular level is employed in this study to estimate the dose enhancement to tumor endothelial cell nuclei, caused by radiation-induced photo/Auger electrons originating from gold nanoparticles (AuNPs) targeting the tumor endothelium, during brachytherapy. Methods: A tumor vascular endothelial cell (EC) is modeled as a slab of 2 {mu}m (thickness) x 10 {mu}m (length) x 10 {mu}m (width). The EC contains a nucleus of 5 {mu}m diameter and thickness of 0.5-1 {mu}m, corresponding to nucleus size 5%-10% of cellular volume, respectively. Analytic calculations based on the electron energy loss formula of Cole were carried out to estimate the dose enhancement to the nucleus caused by photo/Auger electrons from AuNPs attached to the exterior surface of the EC. The nucleus dose enhancement factor (nDEF), representing the ratio of the dose to the nucleus with and without the presence of gold nanoparticles was calculated for different AuNP local concentrations. The investigated concentration range considers the potential for significantly higher local concentration near the EC due to preferential accumulation of AuNP in the tumor vasculature. Four brachytherapy sources: I-125, Pd-103, Yb-169, and 50 kVp x-rays were investigated. Results: For nucleus size of 10% of the cellular volume and AuNP concentrations ranging from 7 to 140 mg/g, brachytherapy sources Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 5.6-73, 4.8-58.3, 4.7-56.6, and 3.2-25.8, respectively. Meanwhile, for nucleus size 5% of the cellular volume in the same concentration range, Pd-103, I-125, 50 kVp, and Yb-169 yielded nDEF values of 6.9-79.2, 5.1-63.2, 5.0-61.5, and 3.3-28.3, respectively. Conclusions: The results predict that a substantial dose boost to the nucleus of endothelial cells can be achieved by applying tumor vasculature-targeted AuNPs in combination with brachytherapy. Such vascular dose boosts could induce tumor vascular shutdown, prompting

  2. Establishment of 60Co dose calibration curve using fluorescent in situ hybridization assay technique: Result of preliminary study

    International Nuclear Information System (INIS)

    Rahimah Abdul Rahim; Noriah Jamal; Noraisyah Mohd Yusof; Juliana Mahamad Napiah; Nelly Bo Nai Lee

    2010-01-01

    This study aims at establishing an in-vitro 60 Co dose calibration curve using Fluorescent In-Situ Hybridization assay technique for the Malaysian National Bio dosimetry Laboratory. Blood samples collected from a female healthy donor were irradiated with several doses of 60 Co radiation. Following culturing of lymphocytes, microscopic slides are prepared, denatured and hybridized. The frequencies of translocation are estimated in the metaphases. A calibration curve was then generated using a regression technique. It shows a good fit to a linear-quadratic model. The results of this study might be useful in estimating absorbed dose for the individual exposed to ionizing radiation retrospectively. This information may be useful as a guide for medical treatment for the assessment of possible health consequences. (author)

  3. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Boel [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); Fasmer, Kristine Eldevik [Haukeland University Hospital, Department of Oncology, Medical Physics Section, Bergen (Norway); Boye, Kjetil [Norwegian Radium Hospital, Oslo University Hospital, Department of Oncology, Oslo (Norway); Rosendahl, Karen; Aukland, Stein Magnus [Haukeland University Hospital, Department of Radiology, Paediatric Section, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway); Trovik, Clement [University of Bergen, Department of Clinical Medicine, Bergen (Norway); Haukeland University Hospital, Department of Surgery, Orthopaedic Section, Bergen (Norway); Biermann, Martin [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway)

    2017-01-15

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether {sup 18}F-fluorodeoxyglucose positron emission tomography - computed tomography ({sup 18}F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  4. Dose estimation in CT exams of the abdomen based on values of DLP; Estimativa da dose em exames de tomografia de abdome com base nos valores de DLP

    Energy Technology Data Exchange (ETDEWEB)

    Kikuti, C.F.; Medeiros, R.B.; Salvadori, P.S.; Costa, D.M.C; D' lppolito, G., E-mail: kikuticf@gmail.com, E-mail: rbitelli2011@gmail.com [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Coordenadoria de Fisica e Higiene das Radiacoes. Departamento de Diagnostico por Imagem

    2013-10-01

    One of the challenges of multidetector computerized tomography is to minimize the risk of ionizing radiation using optimized protocols since higher doses are necessary to obtain high image quality. It was also noted that, due to the geometry in image acquisition using MDCT becomes necessary to estimate dose values consistent with the hypothesis clinically and with the specificities of the tomographic equipment. The aim of this study was to estimate the doses in abdomen exams from the data recorded on the MDCT console and dimensions obtained from DICOM images of patients undergoing different clinical protocols. Were collected, from the image DICOM of 101 exams, values of the dose length product (DLP) provided by Philips Health Care - Brilliance 64 equipment console, in order to relate them with the dose values obtained by means of thermoluminescent dosimeters ( TLD ) of CasSo{sub 4}:Mn placed on the surface of a cylindrical simulator abdomen acrylic manufactured under the technical - operational conditions for a typical abdomen exam. From the data obtained, it was possible to find a factor of 1.16 ( 5 % ) indicating that the DLP values Brilliance 64 console underestimate the doses and this should be used with correction factor to estimate the total dose of the patient. (author)

  5. Estimation of the committed radiation dose resulting from gamma radionuclides ingested with food

    International Nuclear Information System (INIS)

    Piotr Godyn; Agnieszka Dolhanczuk-Srodka; Zbigniew Ziembik; Ewa Moliszewska

    2014-01-01

    The objective of the study was to estimate the value of the radiation dose absorbed in consequence of consumption of popular food products for individual age groups. Potatoes, corn and sugar beet were selected for the study. Edible parts of these plants were collected in experimental fields of the KWS Lochow Polska Sp. z o.o. seeding company in Kondratowice (Poland). On the basis of the obtained study results, it can be stated that in consequence of consumption of the selected food products, people may receive increased doses from both natural and artificial radioactive isotopes. The doses calculated for several age groups do not show any health hazards in consequence of consumption of the tested food. One of the determined radionuclides was 137 Cs; however, its presence in the absorbed dose is lower than the doses from natural radioactive isotopes, in particular 40 K. (author)

  6. Estimation of the population dose from medical X-ray diagnostic examination in Shandong province, China

    International Nuclear Information System (INIS)

    Su Xieming

    1985-01-01

    The exposure doses on the examinated body surface for verious types of X-ray diagnostic examanition in Shandong Province were surveyed. The collective effective dose equivalent in per million population were calculated with the measured results, the ratios of orga absorbed doses to irradiated surface exposure doses and the frequencies of X-ray examination in Shandong Province. The result was 326 man.Sv per million total population in 1980, of which chest fluoroscopies. lumbar spine radiographies and G.I. examination were estimated to be about 78, 9 and 5 precent, respectively

  7. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    International Nuclear Information System (INIS)

    Moore, B; Brady, S; Kaufman, R; Mirro, A

    2014-01-01

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE

  8. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, B; Brady, S; Kaufman, R [St Jude Children' s Research Hospital, Memphis, TN (United States); Mirro, A [Washington University, St. Louis, MO (United States)

    2014-06-15

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

  9. Estimating the whole-body exposure annual dose of radiation workers of petroleum nuclear well logging

    International Nuclear Information System (INIS)

    Tian Yizong; Gao Jianzheng; Liu Wenhong

    2006-01-01

    Objective: By imitating experiment of radioactive sources being installed, to estimate the annual whole-body exposure dose of radiation workers of petroleum nuclear determining wells; Methods: To compre the values of the theory, imitating experiment and γ individual dose monitor calculations. Results: The three values measured above tally with one anather. Conclusion: The annual whole-body exposure doses of radiation workers of petroleum nuclear determining wells are no more than 5 mSv. (authors)

  10. The estimation of radiation effective dose from diagnostic medical procedures in general population of northern Iran

    International Nuclear Information System (INIS)

    Shabestani Monfared, A.; Abdi, R.

    2006-01-01

    The risks of low-dose Ionizing radiation from radiology and nuclear medicine are not clearly determined. Effective dose to population is a very important factor in risk estimation. The study aimed to determine the effective dose from diagnostic radiation medicine in a northern province of Iran. Materials and Methods: Data about various radiologic and nuclear medicine procedures were collected from all radiology and nuclear medicine departments In Mazandaran Province (population = 2,898,031); and using the standard dosimetry tables, the total dose, dose per examination, and annual effective dose per capita as well as the annual gonadal dose per capita were estimated. Results: 655,730 radiologic examinations in a year's period, lead to 1.45 mSv, 0.33 mSv and 0.31 mGy as average effective dose per examination, annual average effective dose to member of the public, and annual average gonadal dose per capita, respectively. The frequency of medical radiologic examinations was 2,262 examinations annually per 10,000 members of population. However, the total number of nuclear medicine examinations in the same period was 7074, with 4.37 mSv, 9.6 μSv and 9.8 μGy, as average effective dose per examination, annual average effective dose to member of the public and annual average gonadal dose per caput, respectively. The frequency of nuclear medicine examination was 24 examinations annually per 10,000 members of population. Conclusion: The average effective dose per examination was nearly similar to other studies. However, the average annual effective dose and annual average gonadal dose per capita were less than the similar values in other reports, which could be due to lesser number of radiation medicine examinations in the present study

  11. Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment

    International Nuclear Information System (INIS)

    Dewji, S.; Bellamy, M.; Leggett, R.; Eckerman, K.; Hertel, N.; Sherbini, S.; Saba, M.

    2015-01-01

    Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ( 131 I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered 131 I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with 131 I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the 131 I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of 131 I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after 131 I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of 131 I

  12. Application of RADTRAN to estimation of doses to persons in enclosed spaces

    International Nuclear Information System (INIS)

    Neuhauser, K.S.

    1992-01-01

    The RADTRAN computer code for transportation risk analysis can be used to estimate doses to persons in enclosed volumes. This application was developed in response to a need to examine consequences of a hypothetical container leak during accident-free transportation by cargo air. The original problem addressed tritium containers, but the method can be applied to any gaseous or suspended particulate material potentially released in an airplane or other enclosed area (e.g., warehouse) under accident-free conditions. Such leakage can occur during shipment of any radioactive gas or material with a gaseous phase. Atmospheric dispersion is normally modeled in RADTRAN as a series of downwind isopleths each of which is assigned a dilution factor (also known as time-integrated concentration or X/Q value). These values are located in look-up tables in RADTRAN and are normally taken from externally performed Gaussian dispersion calculations. The dilution factors are used to estimate inhalation dose to persons in the specified downwind areas

  13. Estimation of the average glandular dose on a team of tomosynthesis

    International Nuclear Information System (INIS)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-01-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  14. Estimation of effective dose and lifetime attributable risk from multiple head CT scans in ventriculoperitoneal shunted children

    International Nuclear Information System (INIS)

    Aw-Zoretic, J.; Seth, D.; Katzman, G.; Sammet, S.

    2014-01-01

    Purpose: The purpose of this review is to determine the averaged effective dose and lifetime attributable risk factor from multiple head computed tomography (CT) dose data on children with ventriculoperitoneal shunts (VPS). Method and materials: A total of 422 paediatric head CT exams were found between October 2008 and January 2011 and retrospectively reviewed. The CT dose data was weighted with the latest IRCP 103 conversion factor to obtain the effective dose per study and the averaged effective dose was calculated. Estimates of the lifetime attributable risk were also calculated from the averaged effective dose using a conversion factor from the latest BEIR VII report. Results: Our study found the highest effective doses in neonates and the lowest effective doses were observed in the 10–18 years age group. We estimated a 0.007% potential increase risk in neonates and 0.001% potential increased risk in teenagers over the base risk. Conclusion: Multiple head CTs in children equates to a slight potential increase risk in lifetime attributable risk over the baseline risk for cancer, slightly higher in neonates relative to teenagers. The potential risks versus clinical benefit must be assessed

  15. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

    International Nuclear Information System (INIS)

    Jarry, G; De Marco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-01-01

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  16. Radon and radium concentrations in bottled waters: An estimate of ingestion doses

    International Nuclear Information System (INIS)

    Duenas, C.; Fernandez, M.C.; Carretero, J.; Liger, E.

    1997-01-01

    Concentration levels of Ra-226 and Rn-222 have been analysed in most of the bottled waters commercially available in Spain. Concentrations up to about 600 Bq/m 3 with a geometric mean of 12 Bq/m 3 were observed for Ra-226. For Rn-222 a geometric mean of 1200 Bq/m 3 with values ranging from 52000 to 1400 Bq/m 3 were measured. Doses resulting from the consumption of these waters were calculated. The effective dose equivalents due to the intake of Ra-226 present in these waters are expected to range from about 102 to 2 μSv·y -1 . Dose equivalents to the stomach due to Rn-222 intake through water consumption are estimated to reach values around 30 μSv·y -1 . (author)

  17. Decommissioning of a 60Co unit and estimation of personal doses

    International Nuclear Information System (INIS)

    Lin, H.; Lin, P.; Liu, T.; Chu, C.

    2003-01-01

    Chang-hua Christian hospital needs to uninstall the 60 Co unit. The mode of this 60 Co teletherapy unit is SHIMADZU RTGS-10. The original lead head was taken as the source container of this 60 Co unit. The source head was dismantled and put into the prepared wooden box, after the source was sealed. This study describes the planning and dismantling of the retirement and transport of the 60 Co unit, and personal doses measured during the procedure. This work estimates the doses of radiation received by exposed workers during the dismantling of the machine. The workers received doses of approximately 53 μSv. This study shows that the original lead head can be used as the source container of this 60 Co unit. The 60 Co machine was smoothly dismantled and transported by conscientious and careful workers, using planned and controlled radiation protection, following the ALARA (as low as reasonably achievable) rule. (author)

  18. Estimation of natural radiation background level and population dose in China

    International Nuclear Information System (INIS)

    Pan Ziqiang

    1992-01-01

    The authors describe in general the natural radiation background level in China, and based on available data present an estimated annual effective dose equivalent of the population to natural radiation that is some 2.3 mSv, of which about 0.54 mSv is from original γ radiation and about 0.8 mSv from radon and its short-lived daughters

  19. High-dose vitamin B6 decreases homocysteine serum levels in patients with schizophrenia and schizoaffective disorders: a preliminary study.

    Science.gov (United States)

    Miodownik, Chanoch; Lerner, Vladimir; Vishne, Tali; Sela, Ben-Ami; Levine, Joseph

    2007-01-01

    Vitamin B6 plays an essential role in the normal functioning of the central nervous system. Normal homocysteine (Hcy) serum level is maintained by remethylation of Hcy to methionine by enzymes that require folic acid and vitamin B12 and by catabolism to cysteine by a vitamin B6-dependent enzyme. These findings may be consistent with the hypothesis that the vitamin B6 status may influence plasma Hcy levels. The aims of this preliminary study were (1) to determine whether a correlation exists between Hcy and vitamin B6 levels in patients with schizophrenia and schizoaffective disorders and (2) to investigate whether treatment with high-dose vitamin B6 may reduce Hcy levels in these patients. In this preliminary study, we enrolled 11 patients with schizophrenia or schizoaffective disorders (7 men and 4 women; mean age +/- SD, 50 +/- 12 years) receiving high doses of vitamin B6 treatment (1200 mg/d) for 12 weeks. Blood samples for the assessment of pyridoxal-5-phosphate and Hcy serum levels were obtained at baseline and after 12 weeks of treatment. Age was significantly positively correlated with Hcy levels at baseline (r = 0.392, P = 0.004). All other parameters, including diagnosis, disease duration, and pyridoxal-5-phosphate serum level, were not correlated with Hcy serum levels at baseline. After vitamin B6 treatment, Hcy serum levels significantly decreased (14.2 +/- 3.4 vs. 11.8 +/- 2.0 micromol/L, respectively, t = 2.679, P = 0.023); this decrease being statistically significant in men but not in women. High doses of vitamin B6 lead to a decrease in Hcy serum level in male patients with schizophrenia or schizoaffective disorder.

  20. A practical and transferable methodology for dose estimation in irradiated spices based on thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    D'Oca, M.C.; Bartolotta, A.; Cammilleri, C.; Giuffrida, S.; Parlato, A.; Di Stefano, V.

    2008-01-01

    Full text: Among the industrial applications of ionizing radiation, the treatment of food for preservation purposes is a worldwide recognized tool, provided that proper and validated identification methods are available and used. The thermoluminescence (TL) dosimetry is the physical method validated by the European Committee for Standardization for food from which silicate minerals can be isolated, such as spices and aromatic herbs. The aim of this work was to set up a reasonably simple procedure, alternative to the recommended one, for the identification of irradiated spices and to estimate at the same time the original dose in the irradiated product, using TL and the additive dose method, even after months storage. We have already shown that the additive dose method can be applied with TL dosimetry, if the TL response of the silicate specimen after extraction is always added to the response after each irradiation; the applied added doses were higher than 1 kGy, that can however give saturation problems. The new proposed methodology makes use of added doses lower than 600 Gy; the entire process can be completed within few hours and a linear fit can be utilized. The method was applied to the silicates extracted from oregano samples soon after the radiation treatment (original dose: 2 - 3 - 5 kGy), and after one year storage at room conditions in the dark (original dose: 1-2 kGy). The procedure allows the identification of irradiated samples, without any false positive, together with an estimation of the dose range

  1. Preliminary estimates of cost savings for defense high level waste vitrification options

    International Nuclear Information System (INIS)

    Merrill, R.A.; Chapman, C.C.

    1993-09-01

    The potential for realizing cost savings in the disposal of defense high-level waste through process and design modificatins has been considered. Proposed modifications range from simple changes in the canister design to development of an advanced melter capable of processing glass with a higher waste loading. Preliminary calculations estimate the total disposal cost (not including capital or operating costs) for defense high-level waste to be about $7.9 billion dollars for the reference conditions described in this paper, while projected savings resulting from the proposed process and design changes could reduce the disposal cost of defense high-level waste by up to $5.2 billion

  2. Dose rate estimates from irradiated light-water-reactor fuel assemblies in air

    International Nuclear Information System (INIS)

    Lloyd, W.R.; Sheaffer, M.K.; Sutcliffe, W.G.

    1994-01-01

    It is generally considered that irradiated spent fuel is so radioactive (self-protecting) that it can only be moved and processed with specialized equipment and facilities. However, a small, possibly subnational, group acting in secret with no concern for the environment (other than the reduction of signatures) and willing to incur substantial but not lethal radiation doses, could obtain plutonium by stealing and processing irradiated spent fuel that has cooled for several years. In this paper, we estimate the dose rate at various distances and directions from typical pressurized-water reactor (PWR) and boiling-water reactor (BWR) spent-fuel assemblies as a function of cooling time. Our results show that the dose rate is reduced rapidly for the first ten years after exposure in the reactor, and that it is reduced by a factor of ∼10 (from the one year dose rate) after 15 years. Even for fuel that has cooled for 15 years, a lethal dose (LD50) of 450 rem would be received at 1 m from the center of the fuel assembly after several minutes. However, moving from 1 to 5 m reduces the dose rate by over a factor of 10, and moving from 1 to 10 m reduces the dose rate by about a factor of 50. The dose rates 1 m from the top or bottom of the assembly are considerably less (about 10 and 22%, respectively) than 1 m from the center of the assembly, which is the direction of the maximum dose rate

  3. Monte Carlo uncertainty analysis of dose estimates in radiochromic film dosimetry with single-channel and multichannel algorithms.

    Science.gov (United States)

    Vera-Sánchez, Juan Antonio; Ruiz-Morales, Carmen; González-López, Antonio

    2018-03-01

    To provide a multi-stage model to calculate uncertainty in radiochromic film dosimetry with Monte-Carlo techniques. This new approach is applied to single-channel and multichannel algorithms. Two lots of Gafchromic EBT3 are exposed in two different Varian linacs. They are read with an EPSON V800 flatbed scanner. The Monte-Carlo techniques in uncertainty analysis provide a numerical representation of the probability density functions of the output magnitudes. From this numerical representation, traditional parameters of uncertainty analysis as the standard deviations and bias are calculated. Moreover, these numerical representations are used to investigate the shape of the probability density functions of the output magnitudes. Also, another calibration film is read in four EPSON scanners (two V800 and two 10000XL) and the uncertainty analysis is carried out with the four images. The dose estimates of single-channel and multichannel algorithms show a Gaussian behavior and low bias. The multichannel algorithms lead to less uncertainty in the final dose estimates when the EPSON V800 is employed as reading device. In the case of the EPSON 10000XL, the single-channel algorithms provide less uncertainty in the dose estimates for doses higher than four Gy. A multi-stage model has been presented. With the aid of this model and the use of the Monte-Carlo techniques, the uncertainty of dose estimates for single-channel and multichannel algorithms are estimated. The application of the model together with Monte-Carlo techniques leads to a complete characterization of the uncertainties in radiochromic film dosimetry. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Chernobyl source term, atmospheric dispersion, and dose estimation

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Harvey, T.F.; Lange, R.

    1988-02-01

    The Chernobyl source term available for long-range transport was estimated by integration of radiological measurements with atmospheric dispersion modeling, and by reactor core radionuclide inventory estimation in conjunction with WASH-1400 release fractions associated with specific chemical groups. These analyses indicated that essentially all of the noble gases, 80% of the radioiodines, 40% of the radiocesium, 10% of the tellurium, and about 1% or less of the more refractory elements were released. Atmospheric dispersion modeling of the radioactive cloud over the Northern Hemisphere revealed that the cloud became segmented during the first day, with the lower section heading toward Scandinavia and the uppper part heading in a southeasterly direction with subsequent transport across Asia to Japan, the North Pacific, and the west coast of North America. The inhalation doses due to direct cloud exposure were estimated to exceed 10 mGy near the Chernobyl area, to range between 0.1 and 0.001 mGy within most of Europe, and to be generally less than 0.00001 mGy within the US. The Chernobyl source term was several orders of magnitude greater than those associated with the Windscale and TMI reactor accidents, while the 137 Cs from the Chernobyl event is about 6% of that released by the US and USSR atmospheric nuclear weapon tests. 9 refs., 3 figs., 6 tabs

  5. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  6. Comparison of single-grain and small-aliquot OSL dose estimates in <3000 years old river sediments from South India

    International Nuclear Information System (INIS)

    Thomas, P.J.; Jain, M.; Juyal, N.; Singhvi, A.K.

    2005-01-01

    We report on OSL dose distributions derived from small-aliquot and single grains of quartz in young fluvial sediments sampled from the Penner River basin, South India. The single-grain dose distributions suggest that 13 out of 19 samples were well bleached. In many well-bleached samples, there was an underestimation in the single-aliquot dose estimates as compared to those from the single grain-the difference between average dose estimates determined by the two methods ranged from ∼1% to 31%. Such a dose underestimation was not detectable in poorly bleached samples. Various possible reasons for the discrepancy between single-grain and small-aliquot dose estimates are discussed. Although there is no satisfactory explanation for this discrepancy, we speculate that the difference in the stimulation wavelengths, 470+/-30nm in the case of single-aliquot and 532nm in the case of single grains, could perhaps be one of the reasons; this may occur because the stimulation wavelength affects the proportion of the medium and slow components in the initial signal

  7. Dose estimation using different ways of irradiation in a group of infants from zones affected by the Chernobyl accident

    International Nuclear Information System (INIS)

    Cruz Suarez, R.; Jova Sed, L.; Corripio, J.A.

    1993-01-01

    A dosimetry study is done to 4506 children from the Republic of Ukraine (69,3%), Belarus (8,1%) and Russian (22,5%) from 659 village and with ages between 1 and 17 years old. The study covers several stages. We can mention, for example, the dose estimation of iodine 121 in thyroids, the dose estimation for contamination with strontium 90 in the field and the calculation of the effective dose integrated in 70 years for the incorporation of cesium 137 in the body of the children, assuming a model of chronic incorporation. The estimation of the effective dose due to the strontium 90 was limited to a small group of 1314 children of those zones where the values of surface contamination of the field with this radionuclide are know

  8. Application of the Monte Carlo method to estimate doses in a radioactive waste drum environment

    International Nuclear Information System (INIS)

    Rodenas, J.; Garcia, T.; Burgos, M.C.; Felipe, A.; Sanchez-Mayoral, M.L.

    2002-01-01

    During refuelling operation in a Nuclear Power Plant, filtration is used to remove non-soluble radionuclides contained in the water from reactor pool. Filter cartridges accumulate a high radioactivity, so that they are usually placed into a drum. When the operation ends up, the drum is filled with concrete and stored along with other drums containing radioactive wastes. Operators working in the refuelling plant near these radwaste drums can receive high dose rates. Therefore, it is convenient to estimate those doses to prevent risks in order to apply ALARA criterion for dose reduction to workers. The Monte Carlo method has been applied, using MCNP 4B code, to simulate the drum containing contaminated filters and estimate doses produced in the drum environment. In the paper, an analysis of the results obtained with the MCNP code has been performed. Thus, the influence on the evaluated doses of distance from drum and interposed shielding barriers has been studied. The source term has also been analysed to check the importance of the isotope composition. Two different geometric models have been considered in order to simplify calculations. Results have been compared with dose measurements in plant in order to validate the calculation procedure. This work has been developed at the Nuclear Engineering Department of the Polytechnic University of Valencia in collaboration with IBERINCO in the frame of an RD project sponsored by IBERINCO

  9. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  10. Estimation of lung tissue doses following exposure to low-LET radiation in the Canadian study of cancer following multiple fluoroscopies

    International Nuclear Information System (INIS)

    Howe, G.R.; Yaffe, M.

    1992-02-01

    Lung tissue doses from exposure to external low-LET radiation have been estimated for each year between 1930 and 1960 for 92,707 tuberculosis patients first treated in Canadian institutions between 1930 and 1952. Many of these patients received multiple chest fluoroscopies together with treatment by artificial pneumothorax, and thus accumulated doses up to 15.7 grays. The estimated doses have been used in a statistical analysis of lung cancer mortality between 1950 and 1987 occurring among 64,698 patients known to be alive at the start of 1950, and followed by linkage to the Canadian national mortality data base. There were substantial variations in the total cumulative lung tissue dose received by the cohort, with 2,490 individuals having doses in excess of 1.7 grays. A total of 1,156 lung cancer deaths was observed in the cohort, and these have been used to estimate relative risks. The most appropriate risk model appears to be a simple linear relative risk function, with an excess relative risk coefficient of 0.089 for an absorbed dose of 1 gray. This contrasts with estimates of relative risk based on the atomic bomb survivors study, for which the excess relative risk coefficient for males 20 years after the first exposure is estimated to be 0.64. The difference is statistically significant. It is postulated that fractionation and dose rate effectiveness factors may account for some of the discrepancy. (Modified author abstract) (14 refs., 20 tabs.)

  11. Radiological Characterization of cuban coffee and estimation of the doses received by the population due to coffee consumption

    International Nuclear Information System (INIS)

    Fernandez Gomez, I.M.; Rodriguez Castro, G.; Perez Sanchez, D.

    1996-01-01

    The purpose of this paper is to study the radioactivity levels in the coffee produced and consumed in our country and to estimate the doses received by the Cuban people due to its consumption. As a results of this study the most relevant radionuclide was K 40 , due to the concentration levels found only considering it when estimating the annual committed dose that is received thought this via. The K 40 concentration value present in the infusion represented a dose for the consumer of 15.6 u Sv/year

  12. Graphical user interface for yield and dose estimations for cyclotron-produced technetium.

    Science.gov (United States)

    Hou, X; Vuckovic, M; Buckley, K; Bénard, F; Schaffer, P; Ruth, T; Celler, A

    2014-07-07

    The cyclotron-based (100)Mo(p,2n)(99m)Tc reaction has been proposed as an alternative method for solving the shortage of (99m)Tc. With this production method, however, even if highly enriched molybdenum is used, various radioactive and stable isotopes will be produced simultaneously with (99m)Tc. In order to optimize reaction parameters and estimate potential patient doses from radiotracers labeled with cyclotron produced (99m)Tc, the yields for all reaction products must be estimated. Such calculations, however, are extremely complex and time consuming. Therefore, the objective of this study was to design a graphical user interface (GUI) that would automate these calculations, facilitate analysis of the experimental data, and predict dosimetry. The resulting GUI, named Cyclotron production Yields and Dosimetry (CYD), is based on Matlab®. It has three parts providing (a) reaction yield calculations, (b) predictions of gamma emissions and (c) dosimetry estimations. The paper presents the outline of the GUI, lists the parameters that must be provided by the user, discusses the details of calculations and provides examples of the results. Our initial experience shows that the proposed GUI allows the user to very efficiently calculate the yields of reaction products and analyze gamma spectroscopy data. However, it is expected that the main advantage of this GUI will be at the later clinical stage when entering reaction parameters will allow the user to predict production yields and estimate radiation doses to patients for each particular cyclotron run.

  13. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  14. Retrospective dosimetry: Preliminary use of the single aliquot regeneration (SAR) protocol for the measurement of quartz dose in young house bricks

    DEFF Research Database (Denmark)

    Banerjee, D.; Bøtter-Jensen, L.; Murray, A.S.

    1999-01-01

    with the expected values based on their known age and confirms the absolute accuracy of the SAR method. It is concluded that a similar to 18 mGy fallout dose component can be detected on a background of similar to 100 mGy; this detection limit is controlled by uncertainties in the natural dose rare measurement......In retrospective dosimetry, the total dose absorbed by some pre-existing dosemeters, such as house bricks or tiles, is used to derive the dose to the population arising from a nuclear accident. This paper uses the newly developed SAR protocol to determine the total dose in young house bricks from...... the vicinity of the Chernobyl reactor site and from Roskilde, Denmark. For these samples, it is shown that high precision (similar to 1%) on the mean estimates of total dose can be achieved with similar to 20 independent measurements. The SAR total dose estimates of two Danish house bricks agree...

  15. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  16. A unified framework for benchmark dose estimation applied to mixed models and model averaging

    DEFF Research Database (Denmark)

    Ritz, Christian; Gerhard, Daniel; Hothorn, Ludwig A.

    2013-01-01

    for hierarchical data structures, reflecting increasingly common types of assay data. We illustrate the usefulness of the methodology by means of a cytotoxicology example where the sensitivity of two types of assays are evaluated and compared. By means of a simulation study, we show that the proposed framework......This article develops a framework for benchmark dose estimation that allows intrinsically nonlinear dose-response models to be used for continuous data in much the same way as is already possible for quantal data. This means that the same dose-response model equations may be applied to both...

  17. Estimated dose to man from uranium milling via the beef/milk food-chain pathway

    Energy Technology Data Exchange (ETDEWEB)

    Rayno, D R

    1983-12-01

    One of the major pathways of radiological exposure to man from uranium milling operations is through the beef/milk food chain. Studies by various investigators have shown the extent of uptake and distribution of 238U, 234U, 230Th, 226Ra, 210Pb, and 210Po in plants and cattle. These long-lived natural radioisotopes, all nuclides of the uranium decay series, are found in concentrated amounts in uranium mill tailings. In this paper, data from these investigations are used to estimate the dose to man from consumption of beef and milk from cattle that have fed on forage contaminated with the tailings. The estimated doses from this technologically enhanced source are compared with those resulting from average dietary intake of these radionuclides from natural sources.

  18. Modified Exponential (MOE) Models: statistical Models for Risk Estimation of Low dose Rate Radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Furukawa, C.; Kawakami, Y.; Magae, J.

    2004-01-01

    Simultaneous inclusion of dose and dose-rate is required to evaluate the risk of long term irradiation at low dose-rates, since biological responses to radiation are complex processes that depend both on irradiation time and total dose. Consequently, it is necessary to consider a model including cumulative dose,dose-rate and irradiation time to estimate quantitative dose-response relationship on the biological response to radiation. In this study, we measured micronucleus formation and (3H) thymidine uptake in U2OS, human osteosarcoma cell line, as indicators of biological response to gamma radiation. Cells were exposed to gamma ray in irradiation room bearing 50,000 Ci 60Co. After irradiation, they were cultured for 24h in the presence of cytochalasin B to block cytokinesis, and cytoplasm and nucleus were stained with DAPI and propidium iodide. The number of binuclear cells bearing a micronucleus was counted under a florescence microscope. For proliferation inhibition, cells were cultured for 48 h after the irradiation and (3h) thymidine was pulsed for 4h before harvesting. We statistically analyzed the data for quantitative evaluation of radiation risk at low dose/dose-rate. (Author)

  19. Relationship between radiation dose estimation in patients submitted to abdominal tomography examination and the body mass index

    International Nuclear Information System (INIS)

    Capaverde, Alexandre da S.; Pimentel, Juliana; Froner, Ana Paula P.; Silva, Ana Maria Marques da

    2014-01-01

    Because of the radiation dose in computed tomography (CT) is relatively high, it is important to have an estimate of the dose to which the patient is submitted, considering parameters and correction factors, so that the value is closer to the real. The objective of this study is to relate the estimated dose in patients undergoing abdominal CT with BMI (Body Mass Index) groups, considering the specific size of the anatomical region. The work developed in a hospital in Porto Alegre, Brazil, using 16 Siemens Somatom Emotion equipment. We selected 30 adult that underwent to CT of the abdomen in January 2014. Of these, 13 using dose reduction mechanism (Care Dose), (Sample 1) and the rest without this mechanism (Sample 2). Registered weight, height, CTDI vol (Computed Tomography Dose Index) and anteroposterior and lateral diameter at the umbilicus. BMI and the correction factor for the dose estimates were calculated, according to the specific size of the abdomen. It was determined the percentage change between the CTDI vol values provided by CT and the value of CTDI vol after application of the correction factor, plus the average percentage change for each BMI group. The mean percentage change was between 54% and 19% for sample 1 and between 35% and 10% for sample 2, the lowest to highest BMI group. There was a reduction in the medium average percent with the increasing of the BMI groups in both samples. A larger sample of individuals for verification of results is required

  20. Pathways analysis and radiation-dose estimates for radioactive residues at formerly utilized MED/AEC sites

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, T.L.; Chee, P.C.; Knight, M.J.; Peterson, J.M.; Roberts, C.J.; Robinson, J.E.; Tsai, S.Y.H.; Yuan, Y.C.

    1983-03-01

    Methods of analysis are developed for estimating the largest individual radiation dose that could result from residual radioactivity at sites identified by the Formerly Utilized Sites Remedial Action Program (FUSRAP) of the US Department of Energy. Two unique aspects of the methods are (1) a systematic structuring of the radiation pathways analysis into source terms, source-to-exposure analysis, and exposure-to-dose analysis, and (2) the systematic use of data on the average concentrations of naturally occurring radionuclides in soil, food, and the human body in order to assess the validity of model calculations and obtain more realistic values. The methods are applied to a typical FUSRAP site in order to obtain generic source-to-dose (D/S) conversion factors for estimating the radiation dose to the maximally exposed individual from a known concentration of radionuclides in the soil. The D/S factors are used to derive soil guidelines, i.e., the limiting concentrations of radionuclides at a typical FUSRAP site that are unlikely to result in individual dose limits that exceed generally accepted radiation protection standards. The results lead to the conclusion that the soil guidelines should not exceed 17, 75, and 300 pCi/g for Ra-226, U-238, and Th-230, respectively.