WorldWideScience

Sample records for practical squid instrument

  1. Robotic 3D SQUID imaging system for practical nondestructive evaluation applications

    International Nuclear Information System (INIS)

    Isawa, K.; Nakayama, S.; Ikeda, M.; Takagi, S.; Tosaka, S.; Kasai, N.

    2005-01-01

    A robotic three-dimensional (3D) scanning superconducting quantum interference device (SQUID) imaging system was developed for practical nondestructive evaluation (NDE) applications. The major feature of this SQUID-NDE system is that the SQUID sensor itself scans in 3D by traveling over the surface of an object during testing without the need for magnetic shielding. This imaging system consists of (i) DC-SQUID gradiometer for effective movement of the sensor, (ii) SQUID sensor manipulator utilizing an articulated-type robot used in industry, (iii) laser charge-coupled-device (CCD) displacement sensor to measure the 3D coordinates of points on the surface of the object, and (iv) computer-aided numerical interpolation scheme for 3D surface reconstruction of the object. The applicability of this system for NDE was demonstrated by successfully detecting artificial damage of cylindrical-shaped steel tubes

  2. High transition-temperature SQUID magnetometers and practical applications

    International Nuclear Information System (INIS)

    Dantsker, E.; Lawrence Berkeley National Lab., CA

    1997-05-01

    The design, fabrication and performance of SQUID magnetometers based on thin films of the high-transition temperature superconductor YBa 2 Cu 3 O 7-x (YBCO) are described. Essential to the achieving high magnetic field resolution at low frequencies is the elimination of 1/f flux noise due to thermally activated hopping of flux vortices between pinning sites in the superconducting films. Through improvements in processing, 1/f noise in single layer YBCO thin films and YBCO-SrTiO 3 -YBCO trilayers was systematically reduced to allow fabrication of sensitive SQUID magnetometers. Both single-layer directly coupled SQUID magnetometers and multilayer magnetometers were fabricated, based on the dc SQUID with bicrystal grain boundary Josephson junctions. Multilayer magnetometers had a lower magnetic field noise for a given physical size due to greater effective sensing areas. A magnetometer consisting of a SQUID inductively coupled to the multiturn input coil of a flux transformer in a flip-chip arrangement had a field noise of 27 fT Hz -1/2 at 1 Hz and 8.5 fT Hz -1/2 at 1 kHz. A multiloop multilayer SQUID magnetometer had a field noise of 37 fT Hz -1/2 at 1 Hz and 18 fT Hz -1/2 at 1 kHz. A three-axis SQUID magnetometer for geophysical applications was constructed and operated in the field in the presence of 60 Hz and radiofrequency noise. Clinical quality magnetocardiograms were measured using multilayer SQUID magnetometers in a magnetically shielded room

  3. High transition-temperature SQUID magnetometers and practical applications

    Energy Technology Data Exchange (ETDEWEB)

    Dantsker, Eugene [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1997-05-01

    The design, fabrication and performance of SQUID magnetometers based on thin films of the high-transition temperature superconductor YBa2Cu3O7-x (YBCO) are described. Essential to the achieving high magnetic field resolution at low frequencies is the elimination of 1/f flux noise due to thermally activated hopping of flux vortices between pinning sites in the superconducting films. Through improvements in processing, 1/f noise in single layer YBCO thin films and YBCO-SrTiO3-YBCO trilayers was systematically reduced to allow fabrication of sensitive SQUID magnetometers. Both single-layer directly coupled SQUID magnetometers and multilayer magnetometers were fabricated, based on the dc SQUID with bicrystal grain boundary Josephson junctions. Multilayer magnetometers had a lower magnetic field noise for a given physical size due to greater effective sensing areas. A magnetometer consisting of a SQUID inductively coupled to the multiturn input coil of a flux transformer in a flip-chip arrangement had a field noise of 27 fT Hz-1/2 at 1 Hz and 8.5 fT Hz-1/2 at 1 kHz. A multiloop multilayer SQUID magnetometer had a field noise of 37 fT Hz-1/2 at 1 Hz and 18 fT Hz-1/2 at 1 kHz. A three-axis SQUID magnetometer for geophysical applications was constructed and operated in the field in the presence of 60 Hz and radiofrequency noise. Clinical quality magnetocardiograms were measured using multilayer SQUID magnetometers in a magnetically shielded room.

  4. SQUID-based Nondestructive Testing Instrument of Dished Niobium Sheets for SRF Cavities

    International Nuclear Information System (INIS)

    Q. S. Shu; I. Ben-Zvi; G. Cheng; I. M. Phipps; J. T. Susta; P. Kneisel; G. Myneni; J. Mast; R. Selim

    2007-01-01

    Currently available technology can only inspect flat sheets and allow the elimination of defective flat sheets before the expensive forming and machining of the SRF cavity half-cells, but it does not eliminate the problem of remaining or uncovered surface impurities after partial chemical etching of the half-cells, nor does it detect any defects that may have been added during the fabrication of the half-cells. AMAC has developed a SQUID scanning system based on eddy current technique that allows the scanning of curved Nb samples that are welded to make superconducting RF cavity half-cells. AMAC SQUID scanning system successfully located the defects (Ta macro particles about 100 mm diameter) in a flat Nb sample (top side) and was able to also locate the defects in a cylindrical surface sample (top side). It is more significant that the system successfully located the defects on the backside of the flat sample and curved sample or 3-mm from the top surface. The 3-D SQUID-based Nondestructive instrument will be further optimized and improved in making SRF cavities and allow inspection and detection during cavity manufacturing for achieving highest accelerating fields

  5. Peer Learning in Instrumental Practicing

    Science.gov (United States)

    Nielsen, Siw G.; Johansen, Guro G.; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation. PMID:29599738

  6. Peer Learning in Instrumental Practicing.

    Science.gov (United States)

    Nielsen, Siw G; Johansen, Guro G; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of "private teaching, private learning" has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy ( N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  7. Peer Learning in Instrumental Practicing

    Directory of Open Access Journals (Sweden)

    Siw G. Nielsen

    2018-03-01

    Full Text Available In higher music education (HME, the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96, where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  8. The SQUID Handbook

    CERN Document Server

    Braginski, Alex I

    2006-01-01

    This two-volume handbook offers a comprehensive and well coordinated presentation of SQUIDs (Superconducting Quantum Interference Devices), including device fundamentals, design, technology, system construction and multiple applications. It is intended to bridge the gap between fundamentals and applications, and will be a valuable textbook reference for graduate students and for professionals engaged in SQUID research and engineering. It will also be of use to specialists in multiple fields of practical SQUID applications, from human brain research and heart diagnostics to airplane and nuclear

  9. Practical course on reactor instrumentation

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2004-06-01

    This course is based on the description of the instrumentation of the TRIGA-reactor Vienna, which is used for training research and isotope production. It comprises the following chapters: 1. instrumentation, 2. calibration of the nuclear channels, 3. rod drop time of the control rods, 4. neutron flux density measurements using compensated ionization, 5. neutron flux density measurement with fission chambers (FC), 6. neutron flux density measurement with self-powered neutron detectors (SPND), 7. pressurized water reactor simulator, 8. verification of the radiation level during reactor operation. There is one appendix about neutron-sensitive thermocouples. (nevyjel)

  10. Cryostats for SQUID magnetometers

    International Nuclear Information System (INIS)

    Testard, O.A.; Locatelli, M.

    1982-05-01

    A non metallic and non magnetic cryostat, with a very low thermal budget and a container type autonomy was developed, to condition S.Q.U.I.D. magnetometers which maximum sensitivity reaches 10 -14 Tesla Hertzsup(-1/2). This instrumentation puts in hand new concepts of composite materials, thermal shock and vibration resistant, multilayer thermal radiative insulation also to the prouve of vibrations with thermal equivalent emissivity lower than 10 -3

  11. Standard practice for instrumented indentation testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice defines the basic steps of Instrumented Indentation Testing (IIT) and establishes the requirements, accuracies, and capabilities needed by an instrument to successfully perform the test and produce the data that can be used for the determination of indentation hardness and other material characteristics. IIT is a mechanical test that measures the response of a material to the imposed stress and strain of a shaped indenter by forcing the indenter into a material and monitoring the force on, and displacement of, the indenter as a function of time during the full loading-unloading test cycle. 1.2 The operational features of an IIT instrument, as well as requirements for Instrument Verification Annex A1), Standardized Reference Blocks (Annex A2) and Indenter Requirements (Annex A3) are defined. This practice is not intended to be a complete purchase specification for an IIT instrument. 1.3 With the exception of the non-mandatory Appendix X4, this practice does not define the analysis necessary...

  12. Evaluation of jumbo squid (Dosidicus gigas byproduct hydrolysates obtained by acid-enzymatic hydrolysis and by autohydrolysis in practical diets for Pacific white shrimp (Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    Mayra Lizett González-Félix

    2014-09-01

    Full Text Available The marine bioprocessing industry offers great potential to utilize byproducts for fish meal replacement in aquafeeds. Jumbo squid is an important fishery commodity in Mexico, but only the mantle is marketed. Head, fins, guts and tentacles are discarded in spite of being protein-rich byproducts. This study evaluated the use of two jumbo squid byproduct hydrolysates obtained by acid-enzymatic hydrolysis (AEH and by autohydrolysis (AH as ingredients in practical diets for shrimp. The hydrolysates were included at levels of 2.5 and 5.0% of the diet dry weight in four practical diets, including a control diet without hydrolysate. Shrimp growth and survival were not significantly affected by the dietary treatments. Postharvest quality of abdominal muscle was evaluated in terms of proximate composition and sensory evaluation. Significantly higher crude protein was observed in the muscle of shrimp fed the highest hydrolysate levels, AH 5% (204.8 g kg- 1 or AEH 5% (201.3 g kg- 1. Sensory analysis of cooked muscle showed significant differences for all variables evaluated: color, odor, flavor, and firmness. It was concluded that Jumbo squid byproducts can be successfully processed by autohydrolysis or acid-enzymatic hydrolysis, and that up to 5.0% of the hydrolysates can be incorporated into shrimp diets without affecting growth or survival.

  13. Tracking Electromagnetic Energy With SQUIDs

    Science.gov (United States)

    2005-01-01

    A superconducting quantum interference device (SQUID) is a gadget used to measure extremely weak signals, specifically magnetic flux. It can detect subtle changes in energy, up to 100 billion times weaker than the electromagnetic energy required to move a compass needle. SQUIDs are used for a variety of testing procedures where extreme sensitivity is required and where the test instrument need not come into direct contact with the test subject. NASA uses SQUIDs for remote, noncontact sensing in a variety of venues, including monitoring the Earth s magnetic field and tracking brain activity of pilots. Scientists at NASA s Goddard Space Flight Center have been making extensive use of this technology, from astrophysical research, to tracking the navigational paths of bees in flight to determine if they are using internal compasses. These very sensitive measurement devices have a wide variety of uses within NASA and even more uses within the commercial realm.

  14. Paleomagnetic Analysis Using SQUID Microscopy

    Science.gov (United States)

    Weiss, Benjamin P.; Lima, Eduardo A.; Fong, Luis E.; Baudenbacher, Franz J.

    2007-01-01

    Superconducting quantum interference device (SQUID) microscopes are a new generation of instruments that map magnetic fields with unprecedented spatial resolution and moment sensitivity. Unlike standard rock magnetometers, SQUID microscopes map magnetic fields rather than measuring magnetic moments such that the sample magnetization pattern must be retrieved from source model fits to the measured field data. In this paper, we presented the first direct comparison between paleomagnetic analyses on natural samples using joint measurements from SQUID microscopy and moment magnetometry. We demonstrated that in combination with apriori geologic and petrographic data, SQUID microscopy can accurately characterize the magnetization of lunar glass spherules and Hawaiian basalt. The bulk moment magnitude and direction of these samples inferred from inversions of SQUID microscopy data match direct measurements on the same samples using moment magnetometry. In addition, these inversions provide unique constraints on the magnetization distribution within the sample. These measurements are among the most sensitive and highest resolution quantitative paleomagnetic studies of natural remanent magnetization to date. We expect that this technique will be able to extend many other standard paleomagnetic techniques to previously inaccessible microscale samples.

  15. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  16. Squids: applications outside the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Falco, C M

    1978-07-01

    Originally thought to be rather esoteric, SQUIDS (superconducting quantum interference devices) have moved from the realms of theory to practical application since 1962. The promise for the not-too-distant future is a superconducting computer, with 10/sup 5/ logic elements in a 1cm cube.

  17. Low noise SQUIDs

    Science.gov (United States)

    de Waal, V. J.

    1983-02-01

    The present investigation deals with the design, fabrication, and limitations of very sensitive SQUID (Superconducting Quantum Interference Device) magnetometers. The SQUID magnetometer is based on a utilization of the Josephson effect. A description of the theoretical background is provided, and high performance DC SQUIDs with submicron niobium Josephson junctions are discussed, taking into account design considerations, fabrication, junction characterization, the performance of the SQUID and input coil, and the gradiometer performance. The simulation and optimization of a DC SQUID with finite capacitance is considered, giving attention to the implementation of a simulation procedure on a hybrid computer.

  18. Low noise SQUIDs

    Energy Technology Data Exchange (ETDEWEB)

    De Waal, V.J.

    1983-01-01

    The present investigation deals with the design, fabrication, and limitations of very sensitive SQUID (Superconducting Quantum Interference Device) magnetometers. The SQUID magnetometer is based on a utilization of the Josephson effect. A description of the theoretical background is provided, and high performance DC SQUIDs with submicron niobium Josephson junctions are discussed, taking into account design considerations, fabrication, junction characterization, the performance of the SQUID and input coil, and the gradiometer performance. The simulation and optimization of a DC SQUID with finite capacitance is considered, giving attention to the implementation of a simulation procedure on a hybrid computer. 129 references.

  19. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  20. Low noise SQUIDS

    International Nuclear Information System (INIS)

    Waal, V.J. de.

    1983-01-01

    The design, fabrication and limitations of very sensitive SQUID magnetometers are described. The SQUID magnetometer is based on the Josephson effect. A very low-noise niobium SQUID is described. It is fabricated with ultra-small niobium junctions with an overlapping area smaller than 1 μm 2 . The photolithographic technique developed for its fabrication, is described. Also an integrated system with a SQUID and a first-order gradiometer on a single substrate is presented. Calculations of the resolution of a dc SQUID containing ideal Josephson junctions according to the RSJ model are presented including a parasitic capacitance. The usefulness of the fabricated SQUIDS as well as some remarks on their performance is considered. (Auth.)

  1. Risk assessment instruments in clinical practice.

    Science.gov (United States)

    Côté, Gilles; Crocker, Anne G; Nicholls, Tonia L; Seto, Michael C

    2012-04-01

    To determine whether the items in one of the most widely validated instruments of violence risk assessment, the Historical-Clinical-Risk Management-20 (HCR-20), are used in review board hearings to assess the risk of violence by people found Not Criminally Responsible on account of Mental Disorder (NCRMD). This study was conducted from October 2004 to August 2006 in Quebec's sole forensic psychiatric hospital and 2 large civil psychiatric hospitals designated for the care of people declared NCRMD in the Montreal metropolitan area. The risk assessments presented by clinicians at annual review board hearings and the boards' rationale for the release or detention of people found NCRMD were contrasted with the risk assessments conducted by the research team using the HCR-20. The final sample was comprised of 96 men. Very few of the risk factors identified by prior research (HCR-20 items) were mentioned in the hearing process, whether in clinical reports, discussions during the hearing, or in the disposition justification. The findings confirm that there remains a significant gap between research evidence and risk assessment practice.

  2. SQUID in NDT

    International Nuclear Information System (INIS)

    Rashdi Shah Ahmad

    2001-01-01

    Superconducting Quantum Interference Device (SQUID) is the most sensitive magnetic flux sensor. It has been used to map the magnetic field on the scalp of human being generated by the brain activity. Currently, a number of groups have tried using SQUID for some special NDT application. This paper reviews some of these work. (Author)

  3. Low noise niobium dc SQUID with a planar input coil

    Science.gov (United States)

    de Waal, V. J.; van den Hamer, P.; Klapwijk, T. M.

    1983-02-01

    A practical all-niobium dc superconducting quantum interference device (SQUID) with a niobium spiral input coil has been developed. The SQUID utilizes submicron Josephson junctions. The best intrinsic energy resolution obtained with a 1-nH SQUID is 4×10-32 J/Hz. A 20-turn 1.2-μH input coil is coupled to a 2.3-nH SQUID with an efficiency of 0.5. The energy resolution with respect to the coil is 1×10-30 J/Hz.

  4. Low noise niobium dc SQUID with a planar input coil

    Energy Technology Data Exchange (ETDEWEB)

    de Waal, V.J.; van den Hamer, P.; Klapwijk, T.M.

    1983-02-15

    A practical all-niobium dc superconducting quantum interference device (SQUID) with a niobium spiral input coil has been developed. The SQUID utilizes submicron Josephson junctions. The best intrinsic energy resolution obtained with a 1-nH SQUID is 4 x 10/sup -32/ J/Hz. A 20-turn 1.2-..mu..H input coil is coupled to a 2.3-nH SQUID with an efficiency of 0.5. The energy resolution with respect to the coil is 1 x 10/sup -30/ J/Hz.

  5. Instrumental performance of an etude after three methods of practice.

    Science.gov (United States)

    Vanden Ark, S

    1997-12-01

    For 80 fifth-grade students three practice conditions (mental, mental with physical simulation, and physical with singing) produced significant mean differences in instrumental performance of an etude. No significant differences were found for traditional, physical practice.

  6. Market Squid Ecology Dataset

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains ecological information collected on the major adult spawning and juvenile habitats of market squid off California and the US Pacific Northwest....

  7. Market Squid Population Dynamics

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains population dynamics data on paralarvae, juvenile and adult market squid collected off California and the US Pacific Northwest. These data were...

  8. Vortex electronis and squids

    CERN Document Server

    2003-01-01

    Understanding the nature of vortices in high-Tc superconductors is a crucial subject for research on superconductive electronics, especially for superconducting interference devices (SQUIDs), it is also a fundamental problem in condensed-matter physics. Recent technological progress in methods for both direct and indirect observation of vortices, e.g. scanning SQUID, terahertz imaging, and microwave excitation, has led to new insights into vortex physics, the dynamic behavior of vortices in junctions and related questions of noise. This book presents the current status of research activity and provides new information on the applications of SQUIDs, including magnetocardiography, immunoassays, and laser-SQUID microscopes, all of which are close to being commercially available.

  9. Vacuum technology Practice for scientific instruments

    CERN Document Server

    Yoshimura, Nagamitsu

    2008-01-01

    Nanotechnology has reached a level where almost every new development and even every new product uses features of nanoscopic properties of materials. As a consequence, an enormous amount of scientific instruments is used in order to synthesize and analyze new structures and materials. Due to the surface sensitivity of such materials, many of these instruments require ultrahigh vacuum that has to be provided under extreme conditions like very high voltages. In this book, Yoshimura provides a review of the UHV related development during the last decades. His very broad experience in the design enables him to present us this detailed reference. After a general description how to design UHV systems, he covers all important issue in detail, like pumps, outgasing, Gauges, and Electrodes for high voltages. Thus, this book serves as reference for everybody using UVH in his scientific equipment

  10. Principle And Practice Of Instrumental Analysis

    International Nuclear Information System (INIS)

    Kim, Chong Il; Kim, Chang Gyo; Oh, Yong Taek

    2010-03-01

    This book gives descriptions of instrumental analysis, which includes quantum physics and chemical foundation with Bohr's adatom model and structure of an electron of atom and the periodic table, analytical theory on analytical chemistry and chemometrics, measurement uncertainty and probability and statistics, state of crystalline materials, structure of crystalline materials, spectroscopy, like infrared spectroscopy and near infrared spectroscopy, electro spectroscopy, mass spectroscopy and Atomic spectroscopy.

  11. SQUID application research in Japan

    International Nuclear Information System (INIS)

    Itozaki, Hideo

    2003-01-01

    Japanese research activities using SQUIDs are reviewed in this paper. Low-T c SQUIDs are applied to multi-channel systems for magnetoencephalogram (MEG) and magnetocardiogram (MCG). High-T c SQUIDs are applied to MCG, nondestructive evaluation (NDE), SQUID microscopy, biological testing using fine magnetic markers, geological surveying, food inspection, large-scale integration (LSI) defect analysis and SQUID-NQR (nuclear quadrupole resonance). These applications of SQUIDs are being researched and developed actively and some of them are expected to be in the commercial market in the near future

  12. Foundations of intervention research in instrumental practice

    Directory of Open Access Journals (Sweden)

    Johannes Lunde Hatfield

    2016-01-01

    Full Text Available The goals of the present study are to evaluate, implement, and adapt psychological skills used in the realm of sports into music performance. This research project also aims to build foundations on how to implement future interventions to guide music students on how to optimize practice toward performance. A two-month psychological skills intervention was provided to two students from the national music academy’s bachelor program in music performance to better understand how to adapt and construct psychological skills training programs for performing music students. The program evaluated multiple intervention tools including the use of questionnaires, performance profiling, iPads, electronic practice logs, recording the perceived value of individual and combined work, as well as the effectiveness of different communication forms. Perceived effects of the intervention were collected through semi-structured interviews, observations, and logs.

  13. Practical considerations in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Ahmad, N.

    2001-01-01

    Activation analysis is a technique of elemental analysis based on the measurement of characteristics radiation from radionuclides formed directly or indirectly by activation. The activation can be induced by bombarding the material with neutrons or charged particles or gamma rays. This is a well-accepted analytical technique for the determination of composition of complex materials. This technique is also sensitive at trace levels and is almost free from analytical interferences of matrix. It is used for multi-elemental determination in rocks, minerals, alloys, biological materials, geological samples, non-destructive analysis of materials and environmental samples such as water, air particulate matter, plants, soil, sediments and diets. This method is also used for production and measurements of radioisotopes in materials of known composition, for example, when radioactivation is used for nuclear reaction studies, for flux and beam intensity measurements for trace experiments and process quality control. In this article the parameters affecting the sensitivity of instrumental neutron activation analysis are briefly discussed. (author)

  14. Nondestructive evaluation of metallic structures using a SQUID magnetometer

    International Nuclear Information System (INIS)

    Weinstock, H.; Nisenoff, M.

    1985-01-01

    We present one of the first reports of the use of SQUID instrumentation for nondestructive evaluation of electrically conducting and ferromagnetic specimens. We report preliminary experiments on the use of SQUIDs for the detection of defects (such as cracks, holes, weld seams, variations in wall thickness, effects of corrosion, etc.) in the walls of a hollow pipe, and for monitoring the magnetic state of a ferromagnetic sample under stress-strain loading conditions. (orig./BUD)

  15. Evaluation Instruments and Good Practices in Online Education

    Science.gov (United States)

    Baldwin, Sally J.; Trespalacios, Jesús

    2017-01-01

    Chickering and Gamson's (1987) "Seven Principles for Good Practice in Undergraduate Education" offers extensively researched and validated tenets for best practices in higher education. After a review of the literature, twenty-eight evaluation instruments currently used to design and review online courses in higher education institutions…

  16. The Stationary SQUID

    Science.gov (United States)

    Berger, Jorge

    2018-06-01

    In the customary mode of operation of a SQUID, the electromagnetic field in the SQUID is an oscillatory function of time. In this situation, electromagnetic radiation is emitted and couples to the sample. This is a back action that can alter the state that we intend to measure. A circuit that could perform as a stationary SQUID consists of a loop of superconducting material that encloses the magnetic flux, connected to a superconducting and to a normal electrode. This circuit does not contain Josephson junctions, or any other miniature feature. We study the evolution of the order parameter and of the electrochemical potential in this circuit; they converge to a stationary regime, and the voltage between the electrodes depends on the enclosed flux. We obtain expressions for the power dissipation and for the heat transported by the electric current; the validity of these expressions does not rely on a particular evolution model for the order parameter. We evaluate the influence of fluctuations. For a SQUID perimeter of the order of 1μ m and temperature 0.9T_c, we obtain a flux resolution of the order of 10^{-5}Φ _0/Hz^{1/2}; the resolution is expected to improve as the temperature is lowered.

  17. Design consideration for dc SQUIDs fabricated in deep sub-micron technology

    International Nuclear Information System (INIS)

    Ketchen, M.B.

    1991-01-01

    Design rules for scaling dc SQUID junctions to optimize SQUID performance have been well known for over a decade, and verified down to the sub-micron regime. Practical SQUIDs having well coupled input coils of usable inductance have generally been fabricated at the 2-5 μm level of lithography. Other technologies, silicon in particular, are now routinely practiced at the 0.5 μm level of lithography with impressive demonstrations at the 0.1-0.25 μm level not uncommon. In this paper the implications of applying such fabrication capability to advance dc SQUID technology are explored. In particular the issues of scaling practical dc SQUIDs down to the 0.1-0.25 μm regime are examined, using as a prototype design the basic washer SQUID with a spiral input coil

  18. Practical considerations in developing an instrument-maintenance plan--

    International Nuclear Information System (INIS)

    Guth, M.A.S.

    1989-01-01

    The author develops a general set of considerations to explain how a consistent, well-organized, prioritized, and adequate time-allowance program plan for routine maintenance can be constructed. The analysis is supplemented with experience from the high flux isotope reactor (HFIR) at US Oak Ridge National Laboratory (ORNL). After the preventive maintenance (PM) problem was defined, the instruments on the schedule were selected based on the manufacturer's design specifications, quality-assurance requirements, prior classifications, experiences with the incidence of breakdowns or calibration, and dependencies among instruments. The effects of repair error in PM should be also studied. The HFIR requires three full-time technicians to perform both PM and unscheduled maintenance. A review is presented of concepts from queuing theory to determine anticipated breakdown patterns. In practice, the pneumatic instruments have a much longer lifetime than the electric/electronic instruments on various reactors at ORNL. Some special considerations and risk aversion in choosing a maintenance schedule

  19. A practicable signal processing algorithm for industrial nuclear instrument

    International Nuclear Information System (INIS)

    Tang Yaogeng; Gao Song; Yang Wujiao

    2006-01-01

    In order to reduce the statistical error and to improve dynamic performances of the industrial nuclear instrument, a practicable method of nuclear measurement signal processing is developed according to industrial nuclear measurement features. The algorithm designed is implemented with a single-chip microcomputer. The results of application in (radiation level gauge has proved the effectiveness of this method). (authors)

  20. Analysis instruments for the performance of Advanced Practice Nursing.

    Science.gov (United States)

    Sevilla-Guerra, Sonia; Zabalegui, Adelaida

    2017-11-29

    Advanced Practice Nursing has been a reality in the international context for several decades and recently new nursing profiles have been developed in Spain as well that follow this model. The consolidation of these advanced practice roles has also led to of the creation of tools that attempt to define and evaluate their functions. This study aims to identify and explore the existing instruments that enable the domains of Advanced Practice Nursing to be defined. A review of existing international questionnaires and instruments was undertaken, including an analysis of the design process, the domains/dimensions defined, the main results and an exploration of clinimetric properties. Seven studies were analysed but not all proved to be valid, stable or reliable tools. One included tool was able to differentiate between the functions of the general nurse and the advanced practice nurse by the level of activities undertaken within the five domains described. These tools are necessary to evaluate the scope of advanced practice in new nursing roles that correspond to other international models of competencies and practice domains. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  1. Satellite-instrument system engineering best practices and lessons

    Science.gov (United States)

    Schueler, Carl F.

    2009-08-01

    This paper focuses on system engineering development issues driving satellite remote sensing instrumentation cost and schedule. A key best practice is early assessment of mission and instrumentation requirements priorities driving performance trades among major instrumentation measurements: Radiometry, spatial field of view and image quality, and spectral performance. Key lessons include attention to technology availability and applicability to prioritized requirements, care in applying heritage, approaching fixed-price and cost-plus contracts with appropriate attention to risk, and assessing design options with attention to customer preference as well as design performance, and development cost and schedule. A key element of success either in contract competition or execution is team experience. Perhaps the most crucial aspect of success, however, is thorough requirements analysis and flowdown to specifications driving design performance with sufficient parameter margin to allow for mistakes or oversights - the province of system engineering from design inception to development, test and delivery.

  2. SQUID technology for geophysical exploration

    International Nuclear Information System (INIS)

    Meyer, Hans-Georg; Stolz, R.; Chwala, A.; Schulz, M.

    2005-01-01

    We report on successful tests of planar LTS SQUID gradiometers on airborne platforms such as helicopter and aircraft. The system works stable and allows profile work without any constraints. In mobile applications the gradient resolution at low frequencies is dominated by motion noise, since the parasitic areas of the SQUID gradiometer lead to strong disturbances if the gradiometer is tilted in the homogenous Earth's magnetic field. The balance can be improved further by software using data of a SQUID magnetometer triple. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Some practical applications of an ICP-MS instrument

    International Nuclear Information System (INIS)

    Meddings, B.; Ng, R.

    1987-01-01

    An early model commercial ICP-MS instrument (PlasmaQuad from VG Isotopes Limited) was acquired more than two years ago. As a typical analytical laboratory in the metallurgical field, the application of the ICP-MS technique to real sample analysis is the authors prime concern. The process of introducing this state-of-the-art instrument into routine analysis will be described. The modifications and limitations necessary to achieve acceptable precision under normal working conditions will be outlined. In most cases, practical problems can be circumvented with some sacrifice in analytical performance in the area of detection limits and dynamic range. In this presentation, specific applications of the ICP-MS technique in the authors laboratory will be discussed. These include trace analysis on high purity metals such as copper, aluminum, cobalt, nickel etc., on refinery feed samples such as nickel sulfate, mixed cobalt and nickel sulfide, cobalt cathode, samarium oxide etc., on alloys such as cobalt-samarium magnetic materials, nickel or cobalt based alloys used in turbine blades etc. Other applications such as the determination of uranium in phosphate rock, trace analysis on fertilizers, water samples and high purity acids will also be mentioned. The solutions to the practical problems encountered in these applications will be discussed. The analytical power of the ICP-MS technique for real sample analysis will be assessed

  4. Correlation between fluxgate and SQUID magnetometer data sets for geomagnetic storms

    Directory of Open Access Journals (Sweden)

    Matladi Thabang

    2014-01-01

    Full Text Available There has always been a need to monitor the near Earth's magnetic field, as this monitoring provides understanding and possible predictions of Space Weather events such as geomagnetic storms. Conventional magnetometers such as fluxgates have been used for decades for Space Weather research. The use of highly sensitive magnetometers such as Superconducting QUantum Interference Devices (SQUIDs, promise to give more insight into Space Weather. SQUIDs are relatively recent types of magnetometers that exploit the superconductive effects of flux quantization and Josephson tunneling to measure magnetic flux. SQUIDs have a very broad bandwidth compared to most conventional magnetometers and can measure magnetic flux as low as a few femtotesla. Since SQUIDs have never been used in Space Weather research, unshielded, it is necessary to investigate if they can be reliable Space Weather instruments. The validation is performed by comparing the frequency content of the SQUID and fluxgate magnetometers, as reported by Phiri.

  5. Virtual instruments in practice. Proceedings of the VIP 2001 Congress

    International Nuclear Information System (INIS)

    Jamal, R.; Jaschinski, H.

    2001-01-01

    The book presents and discusses important new software developments in all fields of metrology. There are competent and clear contributions on the many aspects and applications of computer-aided laboratory measurement, general test bench applications, automotive metrology, intranet and internet metrology, vision and motion, general medical technology, and image processing in medical technology. The focus is on image processing, which has seen rapid development during the past few years, but practical applications in other fields on the basis of LabView or National Instruments products are not neglected. The text is illustrated by pictures and tables and is accompanied by a CD-ROM with a demo version of Measurement Studio [de

  6. Prospects on the application of HTS SQUID magnetometry to nondestructive evaluation (NDE)

    Science.gov (United States)

    Weinstock, H.

    1993-04-01

    In light of recent advances in the fabrication of low-noise HTS SQUIDs, a review is presented on the use of LTS SQUID magnetometry for nondestructive evaluation (NDE). Examples are given on applications relating to defects in steel, subsurface cracks in aircraft frames, and voids in non-metallic structures. HTS SQUIDs may make a significant difference in the acceptance of these applications because sensing coils will be closer to a sample under test, there will be greater instrument portability and the problem of bringing liquid helium to remote locations will be eliminated.

  7. Musical instruments in the 21st century identities, configurations, practices

    CERN Document Server

    Campo, Alberto; Egermann, Hauke; Hardjowirogo, Sarah-Indriyati; Weinzierl, Stefan

    2017-01-01

    By exploring the many different types and forms of contemporary musical instruments, this book contributes to a better understanding of the conditions of instrumentality in the 21st century. Providing insights from science, humanities and the arts, authors from a wide range of disciplines discuss the following questions: · What are the conditions under which an object is recognized as a musical instrument? · What are the actions and procedures typically associated with musical instruments? · What kind of (mental and physical) knowledge do we access in order to recognize or use something as a musical instrument? · How is this knowledge being shaped by cultural conventions and temporal conditions? · How do algorithmic processes 'change the game' of musical performance, and as a result, how do they affect notions of instrumentality? · How do we address the question of instrumental identity within an instrument's design process? · What properties can be used to differentiate successful and unsuccessful ins...

  8. Reducing systematic errors in measurements made by a SQUID magnetometer

    International Nuclear Information System (INIS)

    Kiss, L.F.; Kaptás, D.; Balogh, J.

    2014-01-01

    A simple method is described which reduces those systematic errors of a superconducting quantum interference device (SQUID) magnetometer that arise from possible radial displacements of the sample in the second-order gradiometer superconducting pickup coil. By rotating the sample rod (and hence the sample) around its axis into a position where the best fit is obtained to the output voltage of the SQUID as the sample is moved through the pickup coil, the accuracy of measuring magnetic moments can be increased significantly. In the cases of an examined Co 1.9 Fe 1.1 Si Heusler alloy, pure iron and nickel samples, the accuracy could be increased over the value given in the specification of the device. The suggested method is only meaningful if the measurement uncertainty is dominated by systematic errors – radial displacement in particular – and not by instrumental or environmental noise. - Highlights: • A simple method is described which reduces systematic errors of a SQUID. • The errors arise from a radial displacement of the sample in the gradiometer coil. • The procedure is to rotate the sample rod (with the sample) around its axis. • The best fit to the SQUID voltage has to be attained moving the sample through the coil. • The accuracy of measuring magnetic moment can be increased significantly

  9. SQUID-based measuring systems

    Indian Academy of Sciences (India)

    field produced by a given two-dimensional current density distribution is inverted using the Fourier transform technique. Keywords ... Superconducting quantum interference devices (SQUIDs) are the most sensitive detectors for measurement of ... omagnetic prospecting, detection of gravity waves etc. Judging the importance ...

  10. Compact integrated dc SQUID gradiometer

    Science.gov (United States)

    de Waal, V. J.; Klapwijk, T. M.

    1982-10-01

    An all-niobium integrated system of first-order gradiometer and dc suprconducting quantum interference device (SQUID) has been developed. It is relatively simple to fabricate, has an overall size of 17×12 mm and a sensitivity of 3.5×10-12 T m-1 Hz-1/2.

  11. Compact integrated dc SQUID gradiometer

    Energy Technology Data Exchange (ETDEWEB)

    de Waal, V.J.; Klapwijk, T.M.

    1982-10-01

    An all-niobium integrated system of first-order gradiometer and dc suprconducting quantum interference device (SQUID) has been developed. It is relatively simple to fabricate, has an overall size of 17 x 12 mm and a sensitivity of 3.5 x 10/sup -12/ T m/sup -1/ Hz/sup -1/2/.

  12. STM-SQUID probe microscope

    International Nuclear Information System (INIS)

    Hayashi, Tadayuki; Tachiki, Minoru; Itozaki, Hideo

    2007-01-01

    We have developed a STM-SQUID probe microscope. A high T C SQUID probe microscope was combined with a scanning tunneling microscope for investigation of samples at room temperature in air. A high permeability probe needle was used as a magnetic flux guide to improve the spatial resolution. The probe with tip radius of less than 100 nm was prepared by microelectropolishing. The probe was also used as a scanning tunneling microscope tip. Topography of the sample surface could be measured by the scanning tunneling microscope with high spatial resolution prior to observation by SQUID microscopy. The SQUID probe microscope image could be observed while keeping the distance from the sample surface to the probe tip constant. We observed a topographic image and a magnetic image of Ni fine pattern and also a magnetically recorded hard disk. Furthermore we have investigated a sample vibration method of the static magnetic field emanating from a sample with the aim of achieving a higher signal-to-noise (S/N) ratio

  13. Cold SQUIDs and hot samples

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T.S.C. [Univ. of California, Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley national Lab., CA (United States). Materials Sciences Div.

    1997-05-01

    Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other temperatures, the noise was mostly uncorrelated, suggesting that the relevant vortices were pinned at more than one point along their length. Part 2 describes the design, construction, performance, and applications of a scanning high-{Tc} SQUID microscope optimized for imaging room-temperature objects with very high spatial resolution and magnetic source sensitivity.

  14. How the SQUID was born

    International Nuclear Information System (INIS)

    Silver, Arnold H

    2006-01-01

    I was asked to speak about the discovery and invention of the SQUID at the International Superconducting Electronics Conference (ISEC) 2005 banquet. This narrative is based on my personal recollections of the sequence of events and the motivations. I have edited the text and added figures for clarity. Although it is an old story, it may contain some useful lessons

  15. Properties of high temperature SQUIDS

    International Nuclear Information System (INIS)

    Falco, C.M.; Wu, C.T.

    1978-01-01

    A review is given of the present status of weak links and dc and rf biased SQUIDs made with high temperature superconductors. A method for producing reliable, reproducible devices using Nb 3 Sn is outlined, and comments are made on directions future work should take

  16. Cold SQUIDs and hot samples

    International Nuclear Information System (INIS)

    Lee, T.S.C.; Lawrence Berkeley national Lab., CA

    1997-05-01

    Low transition temperature (low-T c ) and high-T c Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-T c superconductors using two low-T c SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other temperatures, the noise was mostly uncorrelated, suggesting that the relevant vortices were pinned at more than one point along their length. Part 2 describes the design, construction, performance, and applications of a scanning high-T c SQUID microscope optimized for imaging room-temperature objects with very high spatial resolution and magnetic source sensitivity

  17. How the SQUID was born

    Energy Technology Data Exchange (ETDEWEB)

    Silver, Arnold H [Northrop Grumman Space Technology, One Space Park, Redondo Beach, CA 90278 (United States)

    2006-05-15

    I was asked to speak about the discovery and invention of the SQUID at the International Superconducting Electronics Conference (ISEC) 2005 banquet. This narrative is based on my personal recollections of the sequence of events and the motivations. I have edited the text and added figures for clarity. Although it is an old story, it may contain some useful lessons.

  18. Review of Magneto cardiography Technology based on SQUID

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Kwon, H.; Kim, J. M.; Kim, K.; Yu, K. K.; Park, Y. K. [Brain and Cognition Measurement Lab, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2012-04-15

    Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

  19. SQUID biosusceptometry in the measurement of hepatic iron

    International Nuclear Information System (INIS)

    Sheth, Sujit

    2003-01-01

    Individuals with primary or secondary abnormalities of iron metabolism, such as hereditary hemochromatosis and transfusional iron loading, may develop potentially lethal systemic iron overload. Over time, this excess iron is progressively deposited in the liver, heart, pancreas, and other organs, resulting in cirrhosis, heart disease, diabetes and other disorders. Unless treated, death usually results from cardiac failure. The amount of iron in the liver is the best indicator of the amount of iron in the whole body. At present, the only sure way to measure the amount of iron in the liver is to remove a sample of the liver by biopsy. Iron stored in the liver can be magnetized to a small degree when placed in a magnetic field. The amount of magnetization is measured by our instrument, called a superconducting quantum interference device (SQUID) susceptometer. In patients with iron overload, our previous studies have shown that magnetic measurements of liver iron in patients with iron overload are quantitatively equivalent to biochemical determinations on tissue obtained by biopsy. The safety, ease, rapidity, and comfort of magnetic measurements make frequent, serial studies technically feasible and practically acceptable to patients. (orig.)

  20. Detectors for Tomorrow's Instruments

    Science.gov (United States)

    Moseley, Harvey

    2009-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

  1. Effect of thermal processing and canning on cadmium and lead levels in California market squid: the role of metallothioneins.

    Science.gov (United States)

    Galitsopoulou, A; Georgantelis, D; Kontominas, M G

    2013-01-01

    The effects of two common seafood preparation practices (roasting and industrial canning) on the heavy metal content--cadmium (Cd) and lead (Pb)--of various tissues of California market squid were studied. Emphasis was placed on the role of metallothioneins (MT) in Cd and Pb behaviour during processing. Cd and Pb analysis was conducted by a Zeeman GTA-AAS atomic absorption spectrometry system; MT analysis was performed by a mercury saturation assay. Results showed that Cd levels in the mantle and whole squid were considerably affected by both processing practices, reaching a 240% increase in mantle and a 40% increase in whole squid. Interestingly, Cd behaviour was associated with MT changes during squid processing. On the other hand, Pb content was not affected from either processing or associated with MT content in the raw or processed squid. Therefore, processing operations may affect Cd and Pb content differently due to the specific metal bioaccumulation and chemical features of each heavy metal type.

  2. Choosing Assessment Instruments for Bulimia Practice and Outcome Research

    Science.gov (United States)

    Sandberg, Katie; Erford, Bradley T.

    2013-01-01

    Six commonly used instruments for assessment of eating disorders were analyzed. Effect size results from Erford et al.'s (2013) meta-analysis for the treatment of bulimia nervosa were used to compare each scale's ability to measure treatment outcomes for bulimia nervosa. Effect size comparisons indicated higher overall effect sizes using the…

  3. NanoSQUIDs: Basics & recent advances

    Science.gov (United States)

    José Martínez-Pérez, Maria; Koelle, Dieter

    2017-08-01

    Superconducting Quantum Interference Devices (SQUIDs) are one of the most popular devices in superconducting electronics. They combine the Josephson effect with the quantization of magnetic flux in superconductors. This gives rise to one of the most beautiful manifestations of macroscopic quantum coherence in the solid state. In addition, SQUIDs are extremely sensitive sensors allowing us to transduce magnetic flux into measurable electric signals. As a consequence, any physical observable that can be converted into magnetic flux, e.g., current, magnetization, magnetic field or position, becomes easily accessible to SQUID sensors. In the late 1980s it became clear that downsizing the dimensions of SQUIDs to the nanometric scale would encompass an enormous increase of their sensitivity to localized tiny magnetic signals. Indeed, nanoSQUIDs opened the way to the investigation of, e.g., individual magnetic nanoparticles or surface magnetic states with unprecedented sensitivities. The purpose of this chapter is to present a detailed survey of microscopic and nanoscopic SQUID sensors. We will start by discussing the principle of operation of SQUIDs, placing the emphasis on their application as ultrasensitive detectors for small localized magnetic signals. We will continue by reviewing a number of existing devices based on different kinds of Josephson junctions and materials, focusing on their advantages and drawbacks. The last sections are left for applications of nanoSQUIDs in the fields of scanning SQUID microscopy and magnetic particle characterization, placing special stress on the investigation of individual magnetic nanoparticles.

  4. Introduction to focused ion beams instrumentation, theory, techniques and practice

    CERN Document Server

    Giannuzzi, Lucille A

    2005-01-01

    The focused ion beam (FIB) instrument has experienced an intensive period of maturation since its inception. Numerous new techniques and applications have been brought to fruition, and over the past few years, the FIB has gained acceptance as more than just an expensive sample preparation tool. It has taken its place among the suite of other instruments commonly available in analytical and forensic laboratories, universities, geological, medical and biological research institutions, and manufacturing plants. Although the utility of the FIB is not limited to the preparation of specimens for subsequent analysis by other analytical techniques, it has revolutionized the area of TEM specimen preparation. The FIB has also been used to prepare samples for numerous other analytical techniques, and offers a wide range of other capabilities. While the mainstream of FIB usage remains within the semiconductor industry, FIB usage has expanded to applications in metallurgy, ceramics, composites, polymers, geology, art, bio...

  5. DOE Handbook: Guide to good practices evaluation instrument examples

    International Nuclear Information System (INIS)

    1997-01-01

    Training evaluation determines a training program's effectiveness in meeting its intended purpose: producing competent employees. Evaluation is the quality assurance component of a systematic approach to training program. This guide provides information on evaluation instruments used to gather employee, supervisor, and instructor feedback to identify strengths and weaknesses of training programs at DOE facilities. It should be used in conjunction with ''DOE Training Program Handbook: A Systematic Approach to Training'' and ''DOE Handbook, Alternative Systematic Approaches to Training.''

  6. DOE Handbook: Guide to good practices evaluation instrument examples

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-01-01

    Training evaluation determines a training program`s effectiveness in meeting its intended purpose: producing competent employees. Evaluation is the quality assurance component of a systematic approach to training program. This guide provides information on evaluation instruments used to gather employee, supervisor, and instructor feedback to identify strengths and weaknesses of training programs at DOE facilities. It should be used in conjunction with ``DOE Training Program Handbook: A Systematic Approach to Training`` and ``DOE Handbook, Alternative Systematic Approaches to Training.``

  7. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  8. Derivative instruments a guide to theory and practice

    CERN Document Server

    Eales, Brian

    2003-01-01

    The authors concentrate on the practicalities of each class of derivative, so that readers can apply the techniques in practice. Product descriptions are supported by detailed spreadsheet models, illustrating the techniques employed, some which are available on the accompanying companion website. This book is ideal reading for derivatives traders, salespersons, financial engineers, risk managers, and other professionals involved to any extent in the application and analysis of OTC derivatives.* Combines theory with valuation to provide overall coverage of the topic area* Pr

  9. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  10. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  11. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  12. Designing Chemistry Practice Exams for Enhanced Benefits: An Instrument for Comparing Performance and Mental Effort Measures

    Science.gov (United States)

    Knaus, Karen J.; Murphy, Kristen L.; Holme, Thomas A.

    2009-01-01

    The design and use of a chemistry practice exam instrument that includes a measure for student mental effort is described in this paper. Use of such an instrument can beneficial to chemistry students and chemistry educators as well as chemical education researchers from both a content and cognitive science perspective. The method for calculating…

  13. Development and Validation of Teaching Practice Evaluation Instrument for Assessing Chemistry Students' Teaching Skills

    Science.gov (United States)

    Ezeudu, F. O.; Chiaha, G. T. U.; Eze, J. U.

    2013-01-01

    The study was designed to develop and factorially validate an instrument for measuring teaching practice skills of chemistry student-teachers in University of Nigeria, Nsukka. Two research questions guided the study. The design of the study was instrumentation. All the chemistry student-teachers in the Department of Science Education, University…

  14. A new integrated microwave SQUID circuit design

    International Nuclear Information System (INIS)

    Erne, S.N.; Finnegan, T.F.

    1980-01-01

    In this paper we consider the design and operation of a planar thin-film rf-SQUID circuit which can be realized via microwave-integrated-circuit (MIC) techniques and which differs substantially from pervious microwave SQUID configurations involving either mechanical point-contact or cylindrical thin-film micro-bridge geometries. (orig.)

  15. Taking spiritual history in clinical practice: a systematic review of instruments.

    Science.gov (United States)

    Lucchetti, Giancarlo; Bassi, Rodrigo M; Lucchetti, Alessandra L Granero

    2013-01-01

    To facilitate the addressing of spirituality in clinical practice, several authors have created instruments for obtaining a spiritual history. However, in only a few studies have authors compared these instruments. The aim of this study was to compare the most commonly used instruments for taking a spiritual history in a clinical setting. A systematic review of spiritual history assessment was conducted in five stages: identification of instruments used in the literature (databases searching); relevant articles from title and initial abstract review; exclusion and Inclusion criteria; full text retrieval and final analysis of each instrument. A total of 2,641 articles were retrieved and after the analysis, 25 instruments were included. The authors independently evaluated each instrument on 16 different aspects. The instruments with the greatest scores in the final analysis were FICA, SPIRITual History, FAITH, HOPE, and the Royal College of Psychiatrists. Concerning all 25 instruments, 20 of 25 inquire about the influence of spirituality on a person's life and 17 address religious coping. Nevertheless, only four inquire about medical practices not allowed, six deal with terminal events, nine have mnemonics to facilitate their use, and five were validated. FICA, SPIRITual History, FAITH, HOPE, and Royal College of Psychiatrists scored higher in our analysis. The use of each instrument must be individualized, according to the professional reality, time available, patient profile, and settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  17. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  18. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  19. [Instruments for evaluating oral health knowledge, attitudes and practice for parents /caregivers of small children].

    Science.gov (United States)

    Martignon, Stefania; Bautista-Mendoza, Gloria; González-Carrera, María; Lafaurie-Villamil, Gloria; Morales, Veicy; Santamaría, Ruth

    2008-01-01

    Designing three instruments for evaluating oral health knowledge, attitudes and practice in parents/caregivers of low social-economic status 0-5 year-olds. Evaluating the instruments' reliability in terms of internal consistency and analysing items. Three instruments were constructed for evaluating low social-economic status 0-5 year-olds' parents/caregivers' oral health knowledge, attitudes and practice in the municipality of Usaquén , Bogotá , Colombia . 47 parents/caregivers were given a test establishing the instrument's reliability in terms of internal consistency and the adults' level of knowledge, attitudes and practice. A sub-sample was qualitatively analysed (content verification and understanding). Reliability was evaluated using Cronbach's alpha coefficient. Items were analysed for improving constructing and understanding the questions, taking four criteria into account: corrected homogeneity index (CHI), response trend, correlation between items and qualitative analysis. Cronbach's alpha coefficient for knowledge, attitudes and practice was 0,82, 0,80 and 0,62, respectively. Participants' level of knowledge, attitudes and practice was acceptable (60 %, 55 % and 91 %, respectively). This study found two out of the three evaluated instruments to be reliable (knowledge and attitudes); all three of them were then redesigned. The resulting instruments represent a valuable tool which can be used in future studies for describing and evaluating preventative programmes.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  1. High School Instrumental Music Students' Attitudes and Beliefs regarding Practice: An Application of Attribution Theory

    Science.gov (United States)

    Schatt, Matthew D.

    2011-01-01

    The purpose of this study was to explore high school band students' perspectives of instrumental music practice from within the attribution theory paradigm and to attempt to elucidate the secondary student's attitudes toward practice. High school band students from three Midwestern school districts (N = 218) completed a survey that was used to…

  2. Review of SQUID Sensors for Measuring Magnetocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. H.; Kim, J. M.; Yu, K. K.; Kim, K.; Kwon, H. [Brain and Cognition Measurement Lab, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2011-08-15

    Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

  3. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  4. The evolution and development of an instrument to measure essential professional nursing practices.

    Science.gov (United States)

    Kramer, Marlene; Brewer, Barbara B; Halfer, Diana; Hnatiuk, Cynthia Nowicki; MacPhee, Maura; Schmalenberg, Claudia

    2014-11-01

    Nursing continues to evolve from a task-oriented occupation to a holistic professional practice. Increased professionalism requires accurate measurement of care processes and practice. Nursing studies often omit measurement of the relationship between structures in the work environment and processes of care or between processes of care and patient outcomes. Process measurement is integral to understanding and improving nursing practice. This article describes the development of an updated Essentials of Magnetism process measurement instrument for clinical nurses (CNs) practicing on inpatient units in hospitals. It has been renamed Essential Professional Nursing Practices: CN.

  5. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  6. Squid based beam current meter

    International Nuclear Information System (INIS)

    Kuchnir, M.

    1983-01-01

    A SQUID based beam current meter has the capability of measuring the current of a beam with as little as 30 x 155 antiprotons (with a signal to noise ratio of 2). If low noise dc current is used to cancel most of the beam or an up-down counter is used to count auto-resets this sensitivity will be available at any time in the acumulation process. This current meter will therefore be a unique diagnostic tool for optimizing the performance of several Tev I components. Besides requiring liquid helium it seems that its only drawback is not to follow with the above sensitivity a sudden beam change larger than 16 μA, something that could be done using a second one in a less sensitive configuration

  7. Aural Image in Practice: A Multicase Analysis of Instrumental Practice in Middle School Learners

    Science.gov (United States)

    Oare, Steve

    2016-01-01

    This multiple case study examined six adolescent band students engaged in self-directed practice. The students' practice sessions were videotaped. Students provided verbal reports during their practice and again retrospectively while reviewing their video immediately after practice. Students were asked to discuss their choice of practice…

  8. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    Science.gov (United States)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  9. New version of toroidal SQUID sensor

    International Nuclear Information System (INIS)

    Zarembinski, S.; Kachniarz, J.

    1983-01-01

    A report is given on the design and fabrication of a mechanically stable and thermal shock resistant SQUID sensor. The sensor is vacuum sealed while the access to the adjustment of its point contact is left open

  10. SQUIDs in biomagnetism: a roadmap towards improved healthcare

    Science.gov (United States)

    Körber, Rainer; Storm, Jan-Hendrik; Seton, Hugh; Mäkelä, Jyrki P.; Paetau, Ritva; Parkkonen, Lauri; Pfeiffer, Christoph; Riaz, Bushra; Schneiderman, Justin F.; Dong, Hui; Hwang, Seong-min; You, Lixing; Inglis, Ben; Clarke, John; Espy, Michelle A.; Ilmoniemi, Risto J.; Magnelind, Per E.; Matlashov, Andrei N.; Nieminen, Jaakko O.; Volegov, Petr L.; Zevenhoven, Koos C. J.; Höfner, Nora; Burghoff, Martin; Enpuku, Keiji; Yang, S. Y.; Chieh, Jen-Jei; Knuutila, Jukka; Laine, Petteri; Nenonen, Jukka

    2016-11-01

    separated by a tunnel barrier or other weak link. A tiny electric current is able to flow between the superconductors as a supercurrent, without developing a voltage across them. At currents above the ‘critical current’ (maximum supercurrent), however, a voltage is developed. In 1964, Jaklevic et al (1964 Phys. Rev. Lett. 12 159-60) observed quantum interference between two Josephson junctions connected in series on a superconducting loop, giving birth to the dc SQUID. The essential property of the SQUID is that a steady increase in the magnetic flux threading the loop causes the critical current to oscillate with a period of one flux quantum. In today’s SQUIDs, using conventional semiconductor readout electronics, one can typically detect a change in Φ corresponding to 10-6 Φ0 in one second. Although early practical SQUIDs were usually made from bulk superconductors, for example, niobium or Pb-Sn solder blobs, today’s devices are invariably made from thin superconducting films patterned with photolithography or even electron lithography. An extensive description of SQUIDs and their applications can be found in the SQUID Handbooks (Clarke and Braginski 2004 Fundamentals and Technology of SQUIDs and SQUID Systems vol I (Weinheim, Germany: Wiley-VCH), Clarke and Braginski 2006 Applications of SQUIDs and SQUID Systems vol II (Weinheim, Germany: Wiley-VCH)). The roadmap begins (chapter 1) with a brief review of the state-of-the-art of SQUID-based magnetometers and gradiometers for biomagnetic measurements. The magnetic field noise referred to the pick-up loop is typically a few fT Hz-1/2, often limited by noise in the metallized thermal insulation of the dewar rather than by intrinsic SQUID noise. The authors describe a pathway to achieve an intrinsic magnetic field noise as low as 0.1 fT Hz-1/2, approximately the Nyquist noise of the human body. They also descibe a technology to defeat dewar noise. Chapter 2 reviews the neuroscientific and clinical use of

  11. YBCO SQUIDs with unconventional current phase relation

    International Nuclear Information System (INIS)

    Bauch, T.; Johansson, J.; Cedergren, K.; Lindstroem, T.; Lombardi, F.

    2007-01-01

    We have studied the dynamics of YBa 2 Cu 3 O 7-δ (YBCO) dc sperconducting quantum interference devices (SQUIDs) characterized by an unconventional Josephson current phase relation (CPR). We have focused on SQUID configurations with Josephson junctions where the lobe of the order parameter in one electrode is facing a node in the other electrode. This order parameter arrangement should enhance the appearance of a sin(2φ) term in the CPR. The response of the critical current of the dc SQUID, under the effect of an external magnetic field, has been measured in temperature, down to 20 mK. Our experimental data have been compared with numerical simulations of the SQUIDs dynamics by considering a CPR of a single junction of the form I(φ) = I I sin(φ) - I II sin(2φ) where I I and I II are, respectively, the first and second harmonic component. In our devices the values of the sin(2φ) term are such that the fundamental state of the SQUID is naturally double degenerate. This is of great relevance for applications of d-wave SQUIDs in quantum information processing

  12. Examining the Teaching of Science, and Technology and Engineering Content and Practices: An Instrument Modification Study

    Science.gov (United States)

    Love, Tyler S.; Wells, John G.; Parkes, Kelly A.

    2017-01-01

    A modified Reformed Teaching Observation Protocol (RTOP) (Piburn & Sawada, 2000) instrument was used to separately examine eight technology and engineering (T&E) educators' teaching of science, and T&E content and practices, as called for by the "Standards for Technological Literacy: Content for the Study of Technology"…

  13. An Observational Study of Score Study Practices among Undergraduate Instrumental Music Education Majors

    Science.gov (United States)

    Silvey, Brian A.; Montemayor, Mark; Baumgartner, Christopher M.

    2017-01-01

    The purpose of this study was to investigate undergraduate instrumental music education majors' score study practices as they related to the effectiveness of their simulated conducting. Participants (N = 30) were video recorded in two sessions in which they completed a 20-min score study session and a simulated conducting performance. In the first…

  14. A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

    International Nuclear Information System (INIS)

    Yadava, G K; Kuhls-Gilcrist, A T; Rudin, S; Patel, V K; Hoffmann, K R; Bednarek, D R

    2008-01-01

    The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited

  15. Good practices in normal childbirth: reliability analysis of an instrument by Cronbach's Alpha.

    Science.gov (United States)

    Gottems, Leila Bernarda Donato; Carvalho, Elisabete Mesquita Peres De; Guilhem, Dirce; Pires, Maria Raquel Gomes Maia

    2018-01-01

    to analyze the internal consistency of the evaluation instrument of the adherence to the good practices of childbirth and birth care in the professionals, through Cronbach's Alpha Coefficient for each of the dimensions and for the total instrument. this is a descriptive and cross-sectional study performed in obstetric centers of eleven public hospitals in the Federal District, with a questionnaire applied to 261 professionals who worked in the delivery care. The study was attended by 261 professionals, 42.5% (111) nurses and 57.5% (150) physicians. The reliability evaluation of the instrument by the Cronbach Alfa resulted in 0.53, 0.78 and 0.76 for dimensions 1, 2 and 3, after debugging that resulted in the exclusion of 11 items. the instrument obtained Cronbach's alpha of 0.80. There is a need for improvement in the items of dimension 1 that refer to attitudes, knowledge, and practices of the organization of the network of care to gestation, childbirth, and birth. However, it can be applied in the way it is used to evaluate practices based on scientific evidence of childbirth care.

  16. Standard practice for evaluating performance characteristics of ultrasonic Pulse-Echo testing instruments and systems without the use of electronic measurement instruments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice describes procedures for evaluating the following performance characteristics of ultrasonic pulse-echo examination instruments and systems: Horizontal Limit and Linearity; Vertical Limit and Linearity; Resolution - Entry Surface and Far Surface; Sensitivity and Noise; Accuracy of Calibrated Gain Controls. Evaluation of these characteristics is intended to be used for comparing instruments and systems or, by periodic repetition, for detecting long-term changes in the characteristics of a given instrument or system that may be indicative of impending failure, and which, if beyond certain limits, will require corrective maintenance. Instrument characteristics measured in accordance with this practice are expressed in terms that relate to their potential usefulness for ultrasonic testing. Instrument characteristics expressed in purely electronic terms may be measured as described in E1324. 1.2 Ultrasonic examination systems using pulsed-wave trains and A-scan presentation (rf or video) may be ev...

  17. Radiation detection from phase-locked serial dc SQUID arrays

    DEFF Research Database (Denmark)

    Kaplunenko, V. K.; Mygind, Jesper; Pedersen, Niels Falsig

    1993-01-01

    We report on synchronous operation of series arrays of inductively coupled superconducting quantum interference devices (SQUIDs). Each array consisted of N=3 or 11 dc SQUIDs with common inductances providing a strong interaction between neighboring cells. Externally shunted (betac[approximately-e......We report on synchronous operation of series arrays of inductively coupled superconducting quantum interference devices (SQUIDs). Each array consisted of N=3 or 11 dc SQUIDs with common inductances providing a strong interaction between neighboring cells. Externally shunted (betac...

  18. Squids: principles and basic applications in experimental physics

    International Nuclear Information System (INIS)

    Ocio, M.

    1990-01-01

    The basic principles and the description of the technical aspects of SQUIDs (Superconducting Quantum Interference Devices) are described. The applications of SQUIDs in experimental researches and low temperature physics experiments are given. The concepts of fluxoid quantization in a superconductor and Josephson tunnelling are reviewed. The principles, the operation, the noise and the different configurations of r.f. and direct current bias SQUIDs are summarized. The principal characteristics of several SQUIDs are reported

  19. Understanding practice change in community pharmacy: a qualitative research instrument based on organisational theory.

    Science.gov (United States)

    Roberts, Alison S; Hopp, Trine; Sørensen, Ellen Westh; Benrimoj, Shalom I; Chen, Timothy F; Herborg, Hanne; Williams, Kylie; Aslani, Parisa

    2003-10-01

    The past decade has seen a notable shift in the practice of pharmacy, with a strong focus on the provision of cognitive pharmaceutical services (CPS) by community pharmacists. The benefits of these services have been well documented, yet their uptake appears to be slow. Various strategies have been developed to overcome barriers to the implementation of CPS, with varying degrees of success, and little is known about the sustainability of the practice changes they produce. Furthermore, the strategies developed are often specific to individual programs or services, and their applicability to other CPS has not been explored. There seems to be a need for a flexible change management model for the implementation and dissemination of a range of CPS, but before it can be developed, a better understanding of the change process is required. This paper describes the development of a qualitative research instrument that may be utilised to investigate practice change in community pharmacy. Specific objectives included gaining knowledge about the circumstances surrounding attempts to implement CPS, and understanding relationships that are important to the change process. Organisational theory provided the conceptual framework for development of the qualitative research instrument, within which two theories were used to give insight into the change process: Borum's theory of organisational change, which categorizes change strategies as rational, natural, political or open; and Social Network Theory, which helps identify and explain the relationships between key people involved in the change process. A semi-structured affecting practice change found in the literature that warranted further investigation with the theoretical perspectives of organisational change and social networks. To address the research objectives, the instrument covered four broad themes: roles, experiences, strategies and networks. The qualitative research instrument developed in this study provides a

  20. The investigation of rf-squids at liquid nitrogen temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Polushkin, V N; Vasiliev, B V [Joint Inst. for Nuclear Research, Dubna (USSR)

    1989-12-01

    One- and two-hole YBCO ceramic rf-squids operating at liquid nitrogen temperatures have been developed. The main squid parameters: self-inductance, white noise level and magnetic flux resolution were measured. The directly measured external field sensitivity for one-hole squid was at the level of 100 fT/{radical}Hz. (orig.).

  1. The use of (double) relaxation oscillation SQUIDs as a sensor

    NARCIS (Netherlands)

    van Duuren, M.J.; Brons, G.C.S.; Kattouw, H.; Flokstra, Jakob; Rogalla, Horst

    1997-01-01

    Relaxation Oscillation SQUIDs (ROSs) and Double Relaxation Oscillation SQUIDs (DROSs) are based on relaxation oscillations that are induced in hysteretic dc SQUIDs by an external L-R shunt. The relaxation frequency of a ROS varies with the applied flux Φ, whereas the output of a DROS is a dc

  2. Computer model for noise in the dc Squid

    International Nuclear Information System (INIS)

    Tesche, C.D.; Clarke, J.

    1976-08-01

    A computer model for the dc SQUID is described which predicts signal and noise as a function of various SQUID parameters. Differential equations for the voltage across the SQUID including the Johnson noise in the shunted junctions are integrated stepwise in time

  3. A Practitioner's Instrument for Measuring Secondary Mathematics Teachers' Beliefs Surrounding Learner-Centered Classroom Practice.

    Science.gov (United States)

    Lischka, Alyson E; Garner, Mary

    In this paper we present the development and validation of a Mathematics Teaching Pedagogical and Discourse Beliefs Instrument (MTPDBI), a 20 item partial-credit survey designed and analyzed using Rasch measurement theory. Items on the MTPDBI address beliefs about the nature of mathematics, teaching and learning mathematics, and classroom discourse practices. A Rasch partial credit model (Masters, 1982) was estimated from the pilot study data. Results show that item separation reliability is .96 and person separation reliability is .71. Other analyses indicate the instrument is a viable measure of secondary teachers' beliefs about reform-oriented mathematics teaching and learning. This instrument is proposed as a useful measure of teacher beliefs for those working with pre-service and in-service teacher development.

  4. Well coupled, low noise, dc SQUIDS

    International Nuclear Information System (INIS)

    Muhlfelder, B.; Beall, J.A.; Cromar, M.W.; Johnson, W.W.; Ono, R.H.

    1985-01-01

    The authors have designed, fabricated, and tested a Double Transformer (DT) coupled dc SQUID (Superconducting Quantum Interference Device) with low noise, an input inductance of 1μH and a smooth input-output characteristic. A transmission line model is presented to explain a resonance in the input-output characteristic of early versions of this device. Guided by the results of numerical simulations a new version of this device has been built and tested. Experimental results are presented that show that the resonance can be moved to a higher voltage by reducing the area of the SQUID loop. The voltage-external flux characteristic of some of these new devices agrees to within 10% with computer simulations. The minimum detectable energy per unit bandwidth (MDE) referred to the SQUID loop, is 10h, where h is Planck's constant. Computer simulations indicate an MDE of 6h

  5. Parameter tolerance of the SQUID bootstrap circuit

    International Nuclear Information System (INIS)

    Zhang Guofeng; Dong Hui; Xie Xiaoming; Jiang Mianheng; Zhang Yi; Krause, Hans-Joachim; Braginski, Alex I; Offenhäusser, Andreas

    2012-01-01

    We recently demonstrated and analysed the voltage-biased SQUID bootstrap circuit (SBC) conceived to suppress the preamplifier noise contribution in the absence of flux modulation readout. Our scheme contains both the additional voltage and current feedbacks. In this study, we analysed the tolerance of the SBC noise suppression performance to spreads in SQUID and SBC circuit parameters. Analytical results were confirmed by experiments. A one-time adjustable current feedback can be used to extend the tolerance to spreads such as those caused by the integrated circuit fabrication process. This should help to improve the fabrication yield of SBC devices integrated on one chip—as required for multi-channel SQUID systems.

  6. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  7. High Tc Josephson Junctions, SQUIDs and magnetometers

    International Nuclear Information System (INIS)

    Clarke, J.

    1991-01-01

    There has recently been considerable progress in the state-of-the-art of high-T c magnetometers based on dc SQUIDs (Superconducting Quantum Interference Devices). This progress is due partly to the development of more manufacturable Josephson junctions, making SQUIDs easier to fabricate, and partly to the development of multiturn flux transformers that convert the high sensitivity of SQUIDs to magnetic flux to a correspondingly high sensitivity to magnetic field. Needless to say, today's high-T c SQUIDs are still considerably less sensitive than their low-T c counterparts, particularly at low frequencies (f) where their level of 1/f noise remains high. Nonetheless, the performance of the high-T c devices has now reached the point where they are adequate for a number of the less demanding applications; furthermore, as we shall see, at least modest improvements in performance are expected in the near future. In this article, the author outlines these various developments. This is far from a comprehensive review of the field, however, and, apart from Sec. 2, he describes largely his own work. He begins in Sec. 2 with an overview of the various types of Josephson junctions that have been investigated, and in Sec. 3, he describes some of the SQUIDs that have been tested, and assess their performance. Section 4 discuss the development of the multilayer structures essential for an interconnect technology, and, in particular, for crossovers and vias. Section 5 shows how this technology enables one to fabricate multiturn flux transformers which, in turn, can be coupled to SQUIDs to make magnetometers. The performance and possible future improvements in these magnetometers are assessed, and some applications mentioned

  8. Impact of SQUIDs on functional imaging in neuroscience

    International Nuclear Information System (INIS)

    Penna, Stefania Della; Pizzella, Vittorio; Romani, Gian Luca

    2014-01-01

    This paper provides an overview on the basic principles and applications of magnetoencephalography (MEG), a technique that requires the use of many SQUIDs and thus represents one of the most important applications of superconducting electronics. Since the development of the first SQUID magnetometers, it was clear that these devices could be used to measure the ultra-low magnetic signals associated with the bioelectric activity of the neurons of the human brain. Forty years on from the first measurement of magnetic alpha rhythm by David Cohen, MEG has become a fundamental tool for the investigation of brain functions. The simple localization of cerebral sources activated by sensory stimulation performed in the early years has been successively expanded to the identification of the sequence of neuronal pool activations, thus decrypting information of the hierarchy underlying cerebral processing. This goal has been achieved thanks to the development of complex instrumentation, namely whole head MEG systems, allowing simultaneous measurement of magnetic fields all over the scalp with an exquisite time resolution. The latest trends in MEG, such as the study of brain networks, i.e. how the brain organizes itself in a coherent and stable way, are discussed. These sound applications together with the latest technological developments aimed at implementing systems able to record MEG signals and magnetic resonance imaging (MRI) of the head with the same set-up pave the way to high performance systems for brain functional investigation in the healthy and the sick population. (paper)

  9. The physics teacher in the classroom: an instrument to characterize classroom practices

    Directory of Open Access Journals (Sweden)

    Jesuína L. A. Pacca

    2010-03-01

    Full Text Available With the purpose of analyzing and interpreting physics teachers’ performance in the classroom, we elaborated an analysis instrument with five dimensions which aim to describe – i the strategies chosen to conduct learning, ii the abilities mobilized, iii the attitudes in the interaction with students, iv the evaluation the teacher makes of his work and v the meta-evaluation of his practice. The instrument was constructed from constructivist ideas of teaching and learning and empirical data from teachers’ statements about their classes. Through a to and from process we sought coherence of the adopted theory with the nature of data about teachers’ performance. The broader purpose is to provide ground for teachers’ educators about difficulties teachers may find when trying to modify their practices during a professional development program.

  10. Development and validation of an instrument to evaluate science teachers' assessment beliefs and practices

    Science.gov (United States)

    Genc, Evrim

    The primary purpose of this study was to develop a valid and reliable instrument to examine science teachers' assessment beliefs and practices in science classrooms. The present study also investigated the relationship between teachers' beliefs and practices in terms of assessment issues in science, their perceptions of the factors that influenced their assessment practices and their feelings towards high-stakes testing. The participants of the study were 408 science teachers teaching at middle and high school levels in the State of Florida. Data were collected through two modes of administration of the instrument as a paper-and-pencil and a web-based form. The response rate for paper-and-pencil administration was estimated as 68% whereas the response for the web administration was found to be 27%. Results from the various dimensions of validity and reliability analyses revealed that the 24 item-four-factor belief and practice measures were psychometrically sound and conceptually anchored measures of science teachers' assessment beliefs and self-reported practices. Reliability estimates for the belief measure ranged from .83 to .91 whereas alpha values for the practice measure ranged from .56 to .90. Results from the multigroup analysis supported that the instrument has the same theoretical structure across both administration groups. Therefore, future researchers may use either a paper-and-pencil or web-based format of the instrument. This study underscored a discrepancy between what teachers believe and how they act in classroom settings. It was emphasized that certain factors were mediating the dynamics between the belief and the practice. The majority of teachers reported that instruction time, class size, professional development activities, availability of school funding, and state testing mandates impact their assessment routines. Teachers reported that both the preparation process and the results of the test created unbelievable tension both on students and

  11. Design of a hysteretic SQUID as the readout for a dc SQUID

    International Nuclear Information System (INIS)

    Gershenson, M.

    1991-01-01

    This paper present a design for an optimal hysteretic SQUID readout circuit for a DC SQUID, thus eliminating the need for bulky output transformers or resonance matching circuits. The hysteretic readout system, which is based in part on standard sampling theory, is compared to another similar system and shown to be superior in terms of slew rate and immunity of electromagnetic interference. The circuit will be useful in optimizing the performance of biomagnetic systems

  12. A framework and a measurement instrument for sustainability of work practices in long-term care

    Directory of Open Access Journals (Sweden)

    Slaghuis Sarah S

    2011-11-01

    Full Text Available Abstract Background In health care, many organizations are working on quality improvement and/or innovation of their care practices. Although the effectiveness of improvement processes has been studied extensively, little attention has been given to sustainability of the changed work practices after implementation. The objective of this study is to develop a theoretical framework and measurement instrument for sustainability. To this end sustainability is conceptualized with two dimensions: routinization and institutionalization. Methods The exploratory methodological design consisted of three phases: a framework development; b instrument development; and c field testing in former improvement teams in a quality improvement program for health care (N teams = 63, N individual = 112. Data were collected not until at least one year had passed after implementation. Underlying constructs and their interrelations were explored using Structural Equation Modeling and Principal Component Analyses. Internal consistency was computed with Cronbach's alpha coefficient. A long and a short version of the instrument are proposed. Results The χ2- difference test of the -2 Log Likelihood estimates demonstrated that the hierarchical two factor model with routinization and institutionalization as separate constructs showed a better fit than the one factor model (p Conclusions The theoretical framework offers a valuable starting point for the analysis of sustainability on the level of actual changed work practices. Even though the two dimensions routinization and institutionalization are related, they are clearly distinguishable and each has distinct value in the discussion of sustainability. Finally, the subscales conformed to psychometric properties defined in literature. The instrument can be used in the evaluation of improvement projects.

  13. Degree of chronic orofacial pain associated to the practice of musical instruments in orchestra's participants.

    Science.gov (United States)

    de Queiroz, José Renato Cavalcanti; Mollica, Fernanda Brandão; Benetti, Paula; de Araujo, Maria Amélia Maximo; Valera, Márcia Carneiro

    2014-01-01

    The practice of playing musical instruments can affect structures of the head, neck, mouth, and the masticatory system. The aim of this study was to obtain information regarding the prevalence of orofacial pain in musicians according to the type of instrument they play, by applying a specific questionnaire. One hundred and seventeen musicians of Sao Paulo state's orchestras participated in this study. They answered an anamnesis questionnaire with 20 questions regarding their personal data, type of instrument played, hours of daily practice, and presence or absence of orofacial pain according to the Chronic Pain Grade Classification (CPGC). Musicians were divided into two groups in accordance with the risk of affecting TMJ: RG (risk group, including violin, viola, vocalist, trombone, tuba, clarinet and saxophone); CG (control group, other instruments). They received an informative brochure about the subject. Data obtained from the questionnaire were submitted to descriptive statistics, Pearson's correlation analysis and Z-test for difference between two proportions. The participants were from 15 to 62 years old. Pain degree showed positive correlation for reported symptoms (P = 0.002) and hour/day practice (P = 0.030). Regarding the prevalence of pain degree, data were, for RG: Grade 0 (54.5%), Grade 1 (30.3%), and Grade ≥2 (15.1%). For CG, Grade 0 (84.4%), Grade 1 (8.9%), and Grade ≥2 (6.6%). Z-test showed positive difference between groups (P = 0.0001). It was concluded that the musicians of risk group presented higher prevalence of orofacial pain than control (non-risk) group.

  14. Double-barrier junction based dc SQUID

    NARCIS (Netherlands)

    Bartolomé, M.E.; Brinkman, Alexander; Flokstra, Jakob; Golubov, Alexandre Avraamovitch; Rogalla, Horst

    2000-01-01

    dc SQUIDs based on double-barrier Nb/Al/AlOx/Al/AlOx/Al/Nb junctions (DBSQs) have been fabricated and tested for the first time. The current–voltage curves have been measured at temperatures down to 1.4 K. The critical current, Ic, dependence on the temperature T is partially described by the

  15. One Period of Exploration with the Squid.

    Science.gov (United States)

    Bradley, James V.; Ng, Andrew

    1997-01-01

    Presents a lab that can be offered after students have learned the basic anatomy and physiology of the various phyla, the primary objective of which is to explore and apply their acquired knowledge to a new situation. Involves exploring the anatomy and life-style of the squid. (JRH)

  16. Squid Dissection: From Pen to Ink.

    Science.gov (United States)

    Brown, Cindy; Kisiel, Jim

    2003-01-01

    Introduces students to dissection, which is an important part of scientific discovery. Students not only gain an understanding of the anatomy of a squid, but also develop a sense of responsibility and respect for the animal that they are using as a learning tool. (Author/SOE)

  17. High-Tc SQUID Application for Roll to Roll Metallic Contaminant Detector

    International Nuclear Information System (INIS)

    Tanaka, S.; Kitamura, Y.; Uchida, Y.; Hatsukade, Y.; Ohtani, T.; Suzuki, S.

    2012-01-01

    A sensitive eight-channel high-Tc Superconducting Interference Device (SQUID) detection system for magnetic contaminant in a lithium ion battery anode was developed. Finding ultra-small metallic foreign matter is an important issue for a manufacturer because metallic contaminants carry the risk of an internal short. When contamination occurs, the manufacturer of the product suffers a great loss from recalling the tainted product. Metallic particles with outer dimensions smaller than 100 microns cannot be detected using a conventional X-ray imaging system. Therefore, a highly sensitive detection system for small foreign matter is required. We have already developed a detection system based on a single-channel SQUID gradiometer and horizontal magnetization. For practical use, the detection width of the system should be increased to at least 65 mm by employing multiple sensors. In this paper, we present an 8-ch high-Tc SQUID roll-to-roll system for inspecting a lithium-ion battery anode with a width of 65 mm. A special microscopic type of a cryostat was developed upon which eight SQUID gradiometers were mounted. As a result, small iron particles of 35 microns on a real lithium-ion battery anode with a width of 70 mm were successfully detected. This system is practical for the detection of contaminants in a lithium ion battery anode sheet.

  18. How the degree of instrumental practice in music increases perceptual sensitivity.

    Science.gov (United States)

    Proverbio, Alice Mado; Bellini, Eleonora

    2018-04-20

    Literature has shown that playing a musical instrument is associated with the formation of multimodal audio visuomotor representations that are strongly instrument-specific. Here, we investigated the effect of increased motor practice on perceptual sensitivity in 32 professional musicians of comparable expertise but with different amounts of instrumental practice with piano (10,000 vs. 3,000 estimated hours). Stimuli consisted of images of pianists' hands and piano arpeggio sounds. In half of the cases, the piano fingering and piano sounds were congruent, while they were incongruent in the other cases. ERPs were recorded from 128 sites while musicians performed a congruent vs. incongruent discrimination task. A fronto-central error-related negativity (ERN), mainly generated within the anterior cingulate cortex, was observed in response to incongruent videos only in pianists. Non-pianist musicians were able to carry out the task (with a worse performance) but exhibited a smaller response-related N400 to incongruent stimuli. Source reconstruction applied to ERP responses to incongruent stimuli indicated a less automatic mechanism for detecting sensory-motor deviance and a greater emphasis on visual rather than on acoustic features in non-pianists. Overall the data suggest a profound difference between the two populations of musicians and advise against considering "expert" populations to include those that undertook only a few weeks/months of training in a new discipline. Copyright © 2018. Published by Elsevier B.V.

  19. A Practice Indexes for Improving Facial Movements of Brass Instrument Players

    Science.gov (United States)

    Ito, Kyoko; Hirano, Takeshi; Noto, Kazufumi; Nishida, Shogo; Ohtsuki, Tatsuyuki

    Two experimental studies have been conducted in order to propose practice indexes for the improvement of the embouchure of French horn players, two experimental studies have been conducted. In both studies, the same task was performed by advanced and amateur French horn players. The first study investigated the activity, while performing the above-mentioned task, of the 5 facial muscles (levator labii superioris, zygomaticus major, depressor anguli oris, depressor labii inferioris, and risorius muscles) on the right side of the face by surface electromyography, and the facial movement on the left side of the face by attaching two markers above each muscle and using two high-speed cameras simultaneously. The results of the study showed that it is possible for the four markers around the lower lip to practice indexes. The second study evaluated whether the above-mentioned markers are appropriate as practice indexes using a 3-D tracking system and questionnaires. The results showed that both the advanced and the amateur players assessed that the markers were suitable as practice indexes for improving the embouchure. This set of approaches could be useful for selecting practice indexes and developing scientific practice methods not only for the French horn but also for other instruments and other fields.

  20. Validation of an instrument to measure inter-organisational linkages in general practice.

    Science.gov (United States)

    Amoroso, Cheryl; Proudfoot, Judith; Bubner, Tanya; Jayasinghe, Upali W; Holton, Christine; Winstanley, Julie; Beilby, Justin; Harris, Mark F

    2007-12-03

    Linkages between general medical practices and external services are important for high quality chronic disease care. The purpose of this research is to describe the development, evaluation and use of a brief tool that measures the comprehensiveness and quality of a general practice's linkages with external providers for the management of patients with chronic disease. In this study, clinical linkages are defined as the communication, support, and referral arrangements between services for the care and assistance of patients with chronic disease. An interview to measure surgery-level (rather than individual clinician-level) clinical linkages was developed, piloted, reviewed, and evaluated with 97 Australian general practices. Two validated survey instruments were posted to patients, and a survey of locally available services was developed and posted to participating Divisions of General Practice (support organisations). Hypotheses regarding internal validity, association with local services, and patient satisfaction were tested using factor analysis, logistic regression and multilevel regression models. The resulting General Practice Clinical Linkages Interview (GP-CLI) is a nine-item tool with three underlying factors: referral and advice linkages, shared care and care planning linkages, and community access and awareness linkages. Local availability of chronic disease services has no affect on the comprehensiveness of services with which practices link, however, comprehensiveness of clinical linkages has an association with patient assessment of access, receptionist services, and of continuity of care in their general practice. The GP-CLI may be useful to researchers examining comparable health care systems for measuring the comprehensiveness and quality of linkages at a general practice-level with related services, possessing both internal and external validity. The tool can be used with large samples exploring the impact, outcomes, and facilitators of high

  1. The interpersonal relationship in clinical practice. The Barrett-Lennard Relationship Inventory as an assessment instrument.

    Science.gov (United States)

    Simmons, J; Roberge, L; Kendrick, S B; Richards, B

    1995-03-01

    The biomedical model that has long been central to medical practice is gradually being expanded to a broader biopsychosocial model. Relationship-building skills commensurate with the new paradigm need to be understood by educators and taught to medical practitioners. The person-centered, or humanistic, model of psychologist Carl Rogers provides a theoretical approach for the development of effective biopsychosocial relationships. The Barrett-Lennard Relationship Inventory (BLRI) was developed in 1962 as an assessment instrument for the person-centered model. In this article, the person-centered model and the use of the BLRI as an assessment instrument of this model are discussed. Current and potential uses of the BLRI are explored.

  2. Validation of an instrument to measure inter-organisational linkages in general practice

    Directory of Open Access Journals (Sweden)

    Cheryl Amoroso

    2007-11-01

    Full Text Available Purpose: Linkages between general medical practices and external services are important for high quality chronic disease care. The purpose of this research is to describe the development, evaluation and use of a brief tool that measures the comprehensiveness and quality of a general practice’s linkages with external providers for the management of patients with chronic disease. In this study, clinical linkages are defined as the communication, support, and referral arrangements between services for the care and assistance of patients with chronic disease. Methods: An interview to measure surgery-level (rather than individual clinician-level clinical linkages was developed, piloted, reviewed, and evaluated with 97 Australian general practices. Two validated survey instruments were posted to patients, and a survey of locally available services was developed and posted to participating Divisions of General Practice (support organisations. Hypotheses regarding internal validity, association with local services, and patient satisfaction were tested using factor analysis, logistic regression and multilevel regression models. Results: The resulting General Practice Clinical Linkages Interview (GP-CLI is a nine-item tool with three underlying factors: referral and advice linkages, shared care and care planning linkages, and community access and awareness linkages. Local availability of chronic disease services has no affect on the comprehensiveness of services with which practices link, however comprehensiveness of clinical linkages has an association with patient assessment of access, receptionist services, and of continuity of care in their general practice. Conclusions: The GP-CLI may be useful to researchers examining comparable health care systems for measuring the comprehensiveness and quality of linkages at a general practice-level with related services, possessing both internal and external validity. The tool can be used with large samples

  3. Optics and optical instruments an introduction with special reference to practical applications

    CERN Document Server

    Johnson, B K

    1947-01-01

    This book illustrates basic practical applications of optical principle. Working models of telescopes, microscopes, photographic lenses, and optical projection systems are diagrammed and explained in full, as are the basic experiments for determining accuracy, power, angular field of view, amount of aberration, and all other necessary facts about the instrument. Throughout the book, only elementary mathematics is used, for the benefit of the student and the beginner in the field of optics.The author, an assistant professor at the Imperial College of Science and Technology in London, shows ho

  4. Experimental innovations in surface science a guide to practical laboratory methods and instruments

    CERN Document Server

    Yates, John T

    2015-01-01

    This book is a new edition of a classic text on experimental methods and instruments in surface science. It offers practical insight useful to chemists, physicists, and materials scientists working in experimental surface science. This enlarged second edition contains almost 300 descriptions of experimental methods. The more than 50 active areas with individual scientific and measurement concepts and activities relevant to each area are presented in this book. The key areas covered are: Vacuum System Technology, Mechanical Fabrication Techniques, Measurement Methods, Thermal Control, Delivery of Adsorbates to Surfaces, UHV Windows, Surface Preparation Methods, High Area Solids, Safety. The book is written for researchers and graduate students.

  5. SISTEM OTENTIKASI UNTUK SQUID BERBASIS WEB

    Directory of Open Access Journals (Sweden)

    Febriliyan Samopa

    2006-07-01

    Full Text Available Dalam sebuah jaringan komputer terdapat bermacam-macam tipe user dengan berbagi tingkatan yang berbeda yang juga dibutuhkan perlakuan yang berbeda pada tiap user yang disesuaikan dengan kebutuhan dalam menggunakan akses web, baik berupa http, ftp, gopher, dan lain-lain. Dimana masing-masing user memiliki skala prioritas dalam penggunaan bandwidth, jumlah koneksi maksimum, waktu koneksi, ukuran file maksimum, situs yang tidak boleh diakses dan lain-lain. Tujuan dari penelitian ini adalah membuat sebuah perangkat lunak yang dapat melakukan otentikasi user berdasarkan data konfigurasi yang disimpan dalam basisdata. Selain itu, perangkat lunak yang dibuat dapat memproses request dari client berdasarkan data konfigurasi dengan lebih cepat. Permasalahan yang mucul adalah bagaimana merancang dan membuat suatu perangkat lunak yang dapat melakukan otentikasi user berdasarkan data konfigurasi yang diambil dari basisdata, serta dapat memproses request dari client dengan lebih cepat berdasarkan hak akses yang dimilikinya.Dalam penelitian ini didesain dan diimplementasikan suatu sistem otentikasi user dengan mengambil data user yang tersimpan dalam basisdata MySQL. Disamping itu, dilakukan rekayasa pada beberapa rutin proses yang terdapat dalam squid proxy, supaya proses-proses dapat melakukan pengambilan data konfigurasi yang dialihkan dan disimpan dalam basisdata MySQL. Data konfigurasi ini didasarkan pada pembagian hak akses yang dimiliki oleh masing-masing grup user. Antarmuka berbasis web digunakan sebagai salah satu layanan bagi admin untuk mempermudah pengelolaan dan pengolahan data konfigurasi yang dibuat.Berdasarkan uji coba yang telah dilakukan, terbukti sistem yang dibuat dapat bekerja dengan baik dan tidak melenceng dari fungsi asli sebelum dilakukan perubahan. Bahkan pada penanganan request client yang berukuran besar, kinerja squid mengalami peningkatan dalam hal kecepatan proses yang dibutuhkan. Sebagai contoh, request client pada  file

  6. SiGe Integrated Circuit Developments for SQUID/TES Readout

    Science.gov (United States)

    Prêle, D.; Voisin, F.; Beillimaz, C.; Chen, S.; Piat, M.; Goldwurm, A.; Laurent, P.

    2018-03-01

    SiGe integrated circuits dedicated to the readout of superconducting bolometer arrays for astrophysics have been developed since more than 10 years at APC. Whether for Cosmic Microwave Background (CMB) observations with the QUBIC ground-based experiment (Aumont et al. in astro-ph.IM, 2016. arXiv:1609.04372) or for the Hot and Energetic Universe science theme with the X-IFU instrument on-board of the ATHENA space mission (Barret et al. in SPIE 9905, space telescopes & instrumentation 2016: UV to γ Ray, 2016. https://doi.org/10.1117/12.2232432), several kinds of Transition Edge Sensor (TES) (Irwin and Hilton, in ENSS (ed) Cryogenic particle detection, Springer, Berlin, 2005) arrays have been investigated. To readout such superconducting detector arrays, we use time or frequency domain multiplexers (TDM, FDM) (Prêle in JINST 10:C08015, 2016. https://doi.org/10.1088/1748-0221/10/08/C08015) with Superconducting QUantum Interference Devices (SQUID). In addition to the SQUID devices, low-noise biasing and amplification are needed. These last functions can be obtained by using BiCMOS SiGe technology in an Application Specific Integrated Circuit (ASIC). ASIC technology allows integration of highly optimised circuits specifically designed for a unique application. Moreover, we could reach very low-noise and wide band amplification using SiGe bipolar transistor either at room or cryogenic temperatures (Cressler in J Phys IV 04(C6):C6-101, 1994. https://doi.org/10.1051/jp4:1994616). This paper discusses the use of SiGe integrated circuits for SQUID/TES readout and gives an update of the last developments dedicated to the QUBIC telescope and to the X-IFU instrument. Both ASIC called SQmux128 and AwaXe are described showing the interest of such SiGe technology for SQUID multiplexer controls.

  7. Design and Performance of the Multiplexed SQUID/TES Array at Ninety Gigahertz

    Science.gov (United States)

    Stanchfield, Sara; Ade, Peter; Aguirre, James; Brevik, Justus A.; Cho, Hsiao-Mei; Datta, Rahul; Devlin, Mark; Dicker, Simon R.; Dober, Bradley; Duff, Shannon M.; Egan, Dennis; Ford, Pam; Hilton, Gene; Hubmayr, Johannes; Irwin, Kent; Knowles, Kenda; Marganian, Paul; Mason, Brian Scott; Mates, John A. B.; McMahon, Jeff; Mello, Melinda; Mroczkowski, Tony; Romero, Charles; Sievers, Jonathon; Tucker, Carole; Vale, Leila R.; Vissers, Michael; White, Steven; Whitehead, Mark; Ullom, Joel; Young, Alexander

    2018-01-01

    We present the array performance and astronomical images from early science results from MUSTANG-2, a 90 GHz feedhorn-coupled, microwave SQUID-multiplexed TES bolometer array operating on the Robert C. Byrd Green Bank Telescope (GBT). MUSTANG-2 was installed on the GBT on December 2, 2016 and immediately began commissioning efforts, followed by science observations, which are expected to conclude June 2017. The feedhorn and waveguide-probe-coupled detector technology is a mature technology, which has been used on instrument including the South Pole Telescope, the Atacama Cosmology Telescope, and the Atacama B-mode Search telescope. The microwave SQUID readout system developed for MUSTANG-2 currently reads out 66 detectors with a single coaxial cable and will eventually allow thousands of detectors to be multiplexed. This microwave SQUID multiplexer combines the proven abilities of millimeterwave TES detectors with the multiplexing capabilities of KIDs with no degradation in noise performance of the detectors. Each multiplexing device is read out using warm electronics consisting of a commercially available ROACH board, a DAC/ADC card, and an Intermediate Frequency mixer circuit. The hardware was originally developed by the UC Berkeley Collaboration for Astronomy Signal Processing and Electronic Research (CASPER) group, whose primary goal is to develop scalable FPGA-based hardware with the flexibility to be used in a wide range of radio signal processing applications. MUSTANG-2 is the first on-sky instrument to use microwave SQUID multiplexing and is available as a shared-risk/PI instrument on the GBT. In MUSTANG-2's first season 7 separate proposals were awarded a total of 230 hours of telescope time.

  8. Selecting relevant and feasible measurement instruments for the revised Dutch clinical practice guideline for physical therapy in patients after stroke

    NARCIS (Netherlands)

    Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert

    2017-01-01

    Purpose: To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. Methods: In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability

  9. Selecting relevant and feasible measurement instruments for the revised Dutch clinical practice guideline for physical therapy in patients after stroke

    NARCIS (Netherlands)

    Otterman, N.; Veerbeek, J.; Schiemanck, S.; Wees, P.J. van der; Nollet, F.; Kwakkel, G.

    2017-01-01

    PURPOSE: To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. METHODS: In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability

  10. The practical impact of differential item functioning analyses in a health-related quality of life instrument

    DEFF Research Database (Denmark)

    Scott, Neil W; Fayers, Peter M; Aaronson, Neil K

    2009-01-01

    Differential item functioning (DIF) analyses are commonly used to evaluate health-related quality of life (HRQoL) instruments. There is, however, a lack of consensus as to how to assess the practical impact of statistically significant DIF results.......Differential item functioning (DIF) analyses are commonly used to evaluate health-related quality of life (HRQoL) instruments. There is, however, a lack of consensus as to how to assess the practical impact of statistically significant DIF results....

  11. Plan for SQUID microscope at ASRC: Vision, purposes and the present status

    International Nuclear Information System (INIS)

    Kadowaki, K.; Kakeya, I.; Suzuki, J.; Hata, Y.; Hojyo, K

    2001-01-01

    A new research plan to develop SQUID microscope and apply it to advanced science and technology research was started in the year of 2000 at the Advanced Science Research Center (ASRC) of JAERI (Japan Atomic Energy Research Institute). This plan was made to develop 'research of ultrafine magnetic structures with magnetic microscope' and is scheduled to continue five years. Principle of SQUID magnetic microscope is to observe changes of magnetic field in microscopic space using SQUID element as the magnetic probe. At present this type of instrument is fabricated by Seiko Instruments Inc. in Japan and is commercially available. Therefore, this plan is being promoted in collaboration with Seiko Instruments Inc. One of the main issues of the present plan is to raise the spatial resolution to the extremity. As of magnetic microscopes, 'magnetic force microscope' and 'scanning Hall probe microscope' also exist. They have different characteristics of their own. The present plan needs challenging technical developments in various fields. Supposed the spatial resolution be made very high, for example, by making very fine SQUID loop with ultrafine processing, critical technologies like sensitivity, electronics, quantum size effect and so on are to be solved at the same time. Characteristics of the existing instrument are being examined from various aspects. At present, the following three issues are taken up and being studied. (1) High resolution and related technical developments. (2) High sensitivity. (3) High performance of cooling system. Among them, the high resolution is the most serious problem. Completely new design of the SQUID system may be needed. By using the existing instrument, magnetic fluxes trapped on YBCO films are observed and the image quality is being examined. Some of the issues which are considered to be taken up now are listed as follows. (1) Magnetic domain structures on thin film magnetic materials. (2) Observation of structures of Josephson magnetic

  12. Image processing for HTS SQUID probe microscope

    International Nuclear Information System (INIS)

    Hayashi, T.; Koetitz, R.; Itozaki, H.; Ishikawa, T.; Kawabe, U.

    2005-01-01

    An HTS SQUID probe microscope has been developed using a high-permeability needle to enable high spatial resolution measurement of samples in air even at room temperature. Image processing techniques have also been developed to improve the magnetic field images obtained from the microscope. Artifacts in the data occur due to electromagnetic interference from electric power lines, line drift and flux trapping. The electromagnetic interference could successfully be removed by eliminating the noise peaks from the power spectrum of fast Fourier transforms of line scans of the image. The drift between lines was removed by interpolating the mean field value of each scan line. Artifacts in line scans occurring due to flux trapping or unexpected noise were removed by the detection of a sharp drift and interpolation using the line data of neighboring lines. Highly detailed magnetic field images were obtained from the HTS SQUID probe microscope by the application of these image processing techniques

  13. Macroscopic quantum tunneling in a dc SQUID

    International Nuclear Information System (INIS)

    Chen, Y.C.

    1986-01-01

    The theory of macroscopic quantum tunneling is applied to a current-biased dc SQUID whose dynamics can be described by a two-dimensional mechanical system with a dissipative environment. Based on the phenomenological model proposed by Caldeira and Leggett, the dissipative environment is represented by a set of harmonic oscillators coupling to the system. After integrating out the environmental degrees of freedom, an effective Euclidean action is found for the two-dimensional system. The action is used to provide the quantum tunneling rate formalism for the dc SQUID. Under certain conditions, the tunneling rate reduces to that of a single current-biased Josephson junction with an adjustable effective critical current

  14. The Self-assessment Practices of Hong Kong Secondary Students: Findings with a New Instrument.

    Science.gov (United States)

    Yan, Zi

    Self-assessment is a core skill that enables students to engage in self-regulated learning. The purpose of this study was to examine the psychometric properties of a Self-assessment Practice Scale and to depict the characteristics of self-assessment practices of Hong Kong secondary students using this newly developed instrument. A total of 6,125 students from 10 Hong Kong secondary schools completed the survey. Both Rasch and factor analyses revealed a two-dimension scale structure (i.e., Self-directed Feedback Seeking and Self-reflection). The two subscales demonstrated acceptable psychometric properties and suggestions for further improvement were proposed. The findings regarding self-assessment practices of secondary students indicated that, in general, students were quite used to engaging in self-reflection based on available feedback, but they were less disposed to taking the initiative to seek feedback on their own performance. Key demographic variables, e.g., gender and year level, played important roles in students' self-assessment practices. Girls had significantly higher self-assessment measures on both scales than did boys. Junior students had higher measures on both scales than did their senior counterparts. Implications and directions for future research were discussed.

  15. Fundamental characteristics of the QFP measured by the dc SQUID

    International Nuclear Information System (INIS)

    Shimizu, N.; Harada, Y.; Miyamoto, N.; Hosoya, M.; Goto, E.

    1989-01-01

    This paper describes the fundamental characteristics of the Quantum Flux Parametron (QFP) measured by a new method in which the output signals of the QFP are detected with a dc SQUID. The dc SQUID linearly and continuously converts the output current of the QFP to voltage, allowing the output signal of the QFP to be measured as the voltage of the dc SQUID. Thus, the fundamental characteristics of the QFP have been experimentally confirmed in detail

  16. Three common faults in current practice that influence the validity of data obtained from electronic air pollution instrumentation.

    Science.gov (United States)

    Dowd, G; Thomas, R S; Monkman, J L

    1975-01-01

    Instrumental development is now entering a more logical era, where the former artistic character of electronics is being replaced by cold technology. Because of this, one should be expect more reliability; however, there still exist many weak links in practical application. Digital readout systems and computer processing induce a false sense of security. In reality, it is the sample-measurement relationship that determines an instrument's credibility and not the number of digits on its meter. In describing three faulty practices that greatly influence an instrument's performance, it is hoped that measurement may be more closely related to the sample!

  17. Three common faults in current practice that influence the validity of data obtained from electronic air pollution instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Dowd, G; Thomas, R S; Monkman, J L

    1975-01-01

    Instrumental development is now entering a more logical era, where the former artistic character of electronics is being replaced by cold technology. Because of this, one should expect more reliability; however, there still exist many weak links in practical application. Digital readout systems and computer processing induce a false sense of security. In reality, it is the sample-measurement relationship that determines an instrument's credibility and not the number of digits on its meter. In describing three faulty practices that greatly influence an instrument's performance, it is hoped that measurement may be more closely related to the sample.

  18. Hot electron effect in the dc SQUID

    International Nuclear Information System (INIS)

    Wellstood, F.C.; Clarke, J.; Urbina, C.

    1989-01-01

    The authors have investigated the temperature dependence of the noise in thin-film dc Superconducting Quantum Interference Devices (SQUIDs) down to 20 mK. The white noise measured in the early versions of our SQUIDs did not decrease as the bath temperature was lowered below 150 mK. They have attributed this saturation to a hot electron effect in the thin-film AuCu resistors shunting the Josephson junctions. A theoretical investigation showed that the temperature of the electrons in the shunts should be given by T/sub e/ = (P/ΣΩ)/sup 1/5/, where P is the power dissipated in the shunts, Ω is the shunt volume, and Σ is a proportionality constant. Experimentally, the authors found Σ=(2.4+-0.6)X10/sup 9/WK/sup -5/m/sup -3/. They have redesigned the shunts, adding large thin-film cooling fins, to increase their volume substantially. This technique has reduced T/sub e/ to about 50 mK, with a corresponding improvement in the sensitivity of the SQUIDs

  19. Directly coupled YBCO dc SQUID magnetometers

    International Nuclear Information System (INIS)

    Petersen, P.R.E.; Shen, Y.Q.; Holst, T.; Larsen, B.H.; Sager, M.P.; Bindslev Hansen, J.

    1999-01-01

    YBa 2 Cu 3 O 7- x magnetometers have been made on 10mmx10mm MgO substrates by directly coupling the magnetometer pick-up loop to a dc SQUID with narrow strip lines. The dc SQUIDs were made with YBa 2 Cu 3 O 7-x step-edge Josephson junctions. The layout of the magnetometer pick-up loop was chosen as a compromise between maximizing the loop effective area and minimizing the loop inductance. The SQUID was designed to have L S ∼100 pH in order to obtain β L =2I 0 L S /Φ 0 approx.= 1 with the single-junction critical current I 0 ∼10 μA. We have made magnetometers with white noise levels down to 55 fT Hz -1/2 and a 1/f knee at 1 Hz (ac biased). Noise measurements were made on a field-cooled magnetometer. The noise measured at 1 Hz when cooled in 'zero field' was 175 fT Hz -1/2 . When cooled in magnetic fields of B = 50 μT and B = 100 μT we measured the noise at 1 Hz to be 430 fT Hz -1 2 and 1.3 pT Hz -1/2 , respectively. (author)

  20. Recent advancements in the SQUID magnetospinogram system

    Science.gov (United States)

    Adachi, Yoshiaki; Kawai, Jun; Haruta, Yasuhiro; Miyamoto, Masakazu; Kawabata, Shigenori; Sekihara, Kensuke; Uehara, Gen

    2017-06-01

    In this study, a new superconducting quantum interference device (SQUID) biomagnetic measurement system known as magnetospinogram (MSG) is developed. The MSG system is used for observation of a weak magnetic field distribution induced by the neural activity of the spinal cord over the body surface. The current source reconstruction for the observed magnetic field distribution provides noninvasive functional imaging of the spinal cord, which enables medical personnel to diagnose spinal cord diseases more accurately. The MSG system is equipped with a uniquely shaped cryostat and a sensor array of vector-type SQUID gradiometers that are designed to detect the magnetic field from deep sources across a narrow observation area over the body surface of supine subjects. The latest prototype of the MSG system is already applied in clinical studies to develop a diagnosis protocol for spinal cord diseases. Advancements in hardware and software for MSG signal processing and cryogenic components aid in effectively suppressing external magnetic field noise and reducing the cost of liquid helium that act as barriers with respect to the introduction of the MSG system to hospitals. The application of the MSG system is extended to various biomagnetic applications in addition to spinal cord functional imaging given the advantages of the MSG system for investigating deep sources. The study also includes a report on the recent advancements of the SQUID MSG system including its peripheral technologies and wide-spread applications.

  1. Analysis of Squid Net Fisheries Business Production

    Directory of Open Access Journals (Sweden)

    Herna Octivia Damayanti

    2017-03-01

    Full Text Available Squid net is one of alternatives to replace trawl net in Pati regency. The purposes of the research are 1 to determine the influence factors, 2 to analyze the return to scale, 3 to analyze cost and return.The research location in Juwana Subdistrict particularly Bakaran Kulon, Dukutalit, Bajomulyo and Bendar Villages. The research conducted on October 2015 to June 2016. The number of final samples was 36, while the formulation of management strategies used 15 samples by snowball sampling. Data analysis techniques used 1 Cobb Douglas production function, 2 revenue-cost ratio analysis. The results of the research are 1 significant inputs for production factor are long trip, Solar fuel, the number of crew and lights. 2 the return to scale of squid net bussiness in Juwana subdistrict Pati regency is -0.231 means decreasing to scale. 3 the R/C ratio of scenario II more profitable for squid net crews than  scenario I.

  2. Preliminary report on the PIXE analysis of the squid statoliths

    International Nuclear Information System (INIS)

    Ikeda, Yuzuru; Arai, Nobuaki; Sakamoto, Wataru; Murayama, Tatsuro; Maeda, Kuniko; Yoshida, Koji.

    1996-01-01

    Micro trace elements in the squid statolith, a calcareous stone which acts as a balancer and hearing, was analyzed with Particle Induced X-ray Emission (PIXE) for the Japanese common squid for the first time. Calcium is the main component of the squid statoliths, which means that squid statolith is the pure calcified structure similar to the fish otolith. Beside Ca, Sr was detected with strong dosage, and some other elements as Mn, Fe, Cu, Zn and As were also detected. Possible assumption of intake of microelements to the statoliths and the suitability of PIXE for statoliths analysis are discussed. (author)

  3. SQUIDs for the readout of metallic magnetic calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Ferring, Anna; Wegner, Mathias; Fleischmann, Andreas; Gastaldo, Loredana; Kempf, Sebastian; Enss, Christian [Kirchhoff-Institute for Physics, Heidelberg University (Germany)

    2015-07-01

    Superconducting quantum interference devices (SQUIDs) are the devices of choice to read out metallic magnetic calorimeters (MMCs). Here, the temperature change of the detector upon the absorption of an energetic particle is measured as a magnetization change of a paramagnetic temperature sensor that is situated in a weak magnetic field. Driven by the need for devices that allow for the readout of large-scale detector arrays with hundreds or even thousands of individual detectors as well as of single channel detectors with sub-eV energy resolution, we have recently started the development of low-T{sub c} current-sensing SQUIDs. In particular, we are developing cryogenic frequency-domain multiplexers based on non-hysteretic rf-SQUIDs for detector array readout as well as dc-SQUIDs for single channel detector readout. We discuss our SQUID designs and the performance of prototype SQUIDs. We particularly focus on the frequency and temperature dependence of the SQUID noise as well as the reliability of our SQUID fabrication process for Nb/Al-AlO{sub x}/Nb Josephson junctions. Additionally, we demonstrate experimentally that state-of-the-art MMCs can successfully be read out with our current devices. Finally, we discuss different strategies to improve the SQUID and detector performance aiming to reach sub-eV energy resolution for individual detectors as well as for detector arrays.

  4. Antioxidant and antimicrobial activities of squid ink powder

    OpenAIRE

    Fatimah Zaharah, M.Y.; Rabeta, M.S.

    2017-01-01

    Economic development in Malaysia has led to increasing quantity and complexity of generated waste or by-product. The main objective of this study is to investigate the antioxidant and antimicrobial activities of squid ink powder. The squid ink was collected from fresh squid and dried using freeze dryer before it was ground into powder. The yield of squid ink was 22.82% after freeze-drying which was 69.37g in amount. Proximate composition analysis as well as two total antioxidant activity assa...

  5. Allometry indicates giant eyes of giant squid are not exceptional.

    Science.gov (United States)

    Schmitz, Lars; Motani, Ryosuke; Oufiero, Christopher E; Martin, Christopher H; McGee, Matthew D; Gamarra, Ashlee R; Lee, Johanna J; Wainwright, Peter C

    2013-02-18

    The eyes of giant and colossal squid are among the largest eyes in the history of life. It was recently proposed that sperm whale predation is the main driver of eye size evolution in giant squid, on the basis of an optical model that suggested optimal performance in detecting large luminous visual targets such as whales in the deep sea. However, it is poorly understood how the eye size of giant and colossal squid compares to that of other aquatic organisms when scaling effects are considered. We performed a large-scale comparative study that included 87 squid species and 237 species of acanthomorph fish. While squid have larger eyes than most acanthomorphs, a comparison of relative eye size among squid suggests that giant and colossal squid do not have unusually large eyes. After revising constants used in a previous model we found that large eyes perform equally well in detecting point targets and large luminous targets in the deep sea. The eyes of giant and colossal squid do not appear exceptionally large when allometric effects are considered. It is probable that the giant eyes of giant squid result from a phylogenetically conserved developmental pattern manifested in very large animals. Whatever the cause of large eyes, they appear to have several advantages for vision in the reduced light of the deep mesopelagic zone.

  6. Comprehensive Care Plan Development Using Resident Assessment Instrument Framework: Past, Present, and Future Practices

    Directory of Open Access Journals (Sweden)

    Mary Ellen Dellefield

    2015-10-01

    Full Text Available Development of the comprehensive care plan (CCP is a requirement for nursing homes participating in the federal Medicare and Medicaid programs, referred to as skilled nursing facilities. The plan must be developed within the context of the comprehensive interdisciplinary assessment framework—the Resident Assessment Instrument (RAI. Consistent compliance with this requirement has been difficult to achieve. To improve the quality of CCP development within this framework, an increased understanding of complex factors contributing to inconsistent compliance is required. In this commentary, we examine the history of the comprehensive care plan; its development within the RAI framework; linkages between the RAI and registered nurse staffing; empirical evidence of the CCP’s efficacy; and the limitations of extant standards of practices in CCP development. Because of the registered nurse’s educational preparation, professional practice standards, and licensure obligations, the essential contributions of professional nurses in CCP development are emphasized. Recommendations for evidence-based micro and macro level practice changes with the potential to improve the quality of CCP development and regulatory compliance are presented. Suggestions for future research are given.

  7. Inductance-dependent characteristics of HTS dc-SQUID amplifiers

    International Nuclear Information System (INIS)

    Mitchell, E.E.; Tilbrook, D.L.; Foley, C.P.; MacFarlane, J.

    2002-01-01

    Full text: We have experimentally determined the transfer function V Φ and noise S Φ of several high temperature superconducting (HTS) dc SQUIDs of increasing loop size, while they were operated (without input flux transformer) in a small-signal-amplifier (open-loop) mode. A primary aim of our investigation was to provide reliable inductance data to aid our design of subsequent magnetometer devices. Flux was induced by means of current injection via a well-defined stripline directly into the SQUID loop. The loop size was systematically incremented in a range of otherwise similar SQUIDs. For each SQUID, the ratio between the induced flux and the injection current (which we define as the coupling inductance of the device, L c ) was measured as a function of the injection path length and the SQUID loop dimensions. Both L c and the derived SQUID self-inductance, L sq , were then compared with theoretical values, and contributions due to kinetic inductance and junction inductance were estimated. Correlations between the inductance data and our measured values of transfer function V Φ and noise S Φ were compared with previous results. Guidelines for optimisation of gradiometer SQUIDs were established, and in particular, the importance of achieving a large value transfer function together with a relatively small inductance was demonstrated. The strong influence of an enhanced transfer function was further emphasised when an order-of-magnitude reduction in noise was achieved by subjecting one of our SQUIDs to an in-house 'ion-beam trimming' process

  8. SQUID magnetometry from nanometer to centimeter length scales

    International Nuclear Information System (INIS)

    Hatridge, Michael J.

    2010-01-01

    The development of Superconducting QUantum Interference Device (SQUID)-based magnetometer for two applications, in vivo prepolarized, ultra-low field MRI of humans and dispersive readout of SQUIDs for micro- and nano-scale magnetometery, are the focus of this thesis.

  9. SQUID magnetometry from nanometer to centimeter length scales

    Energy Technology Data Exchange (ETDEWEB)

    Hatridge, Michael J. [Univ. of California, Berkeley, CA (United States)

    2010-06-01

    The development of Superconducting QUantum Interference Device (SQUID)-based magnetometer for two applications, in vivo prepolarized, ultra-low field MRI of humans and dispersive readout of SQUIDs for micro- and nano-scale magnetometery, are the focus of this thesis.

  10. The Parental Bonding Instrument: A psychometric measure to assess parenting practices in the homes in Bangladesh.

    Science.gov (United States)

    Karim, A K M Rezaul; Begum, Taslima

    2017-02-01

    There is growing importance of the Parental Bonding Instrument (PBI) in clinical practice and research on parenting and parental bonding. Since the development of this diagnostic tool (Parker et al., Brit. J. Med. Psycho.1979; 52:1-10), a number of validation studies have been done in various cultures. The aim of the present study was to translate the measure into Bangla and validate in Bangladeshi culture. A total of 200 adolescents participated in the study. Exploratory factor analysis (EFA) of the data from 191 participants (who provided complete responses) identified a two-factor (Care and Overprotection) structure of the PBI with 17 items. The two factors together explained 44.18% of the total variance. The factors showed moderate to very high internal consistency (Cronbach's α=0.863 for Care; 0.622 for Overprotection), and very strong convergent and discriminant validity as evident by their correlations with the measures of cognitive distortions and antisocial behaviors. In line with the original tool we defined four types of parenting style, such as Affectionate constraint, Affectionless control, Optimal parenting, and Neglectful parenting. This study opens the door of future research on parenting practices and parent-child relationships in Bangladesh. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Universal mechanisms of decoherence of qubit states in a SQUID

    Science.gov (United States)

    Kuklov, A. B.; Chudnovsky, E. M.

    2003-03-01

    Fundamental conservation laws mandate parameter-free generic mechanisms of decoherence of quantum oscillations of the superconducting current in a SQUID [1]. The very fact that the current flows with respect to the ion lattice is shown to result in a decoherence via emission of the transverse sound at the oscillation frequency. For SQUIDs larger than the wavelength of the phonons, this effect can significantly limit the quality factor. The decohering effects of the external mechanical and magnetic noise are shown to be proportional to the total magnetic moment of the SQUID, making small SQUIDs less susceptible to the noise than large SQUIDs. Decoherence due to the emission of photons into the open space and in the presence of the metal shielding has been studied as well. Suggestions of experimental setups with low decoherence have been made. [1] E. M. Chudnovsky and A. B. Kuklov, arXiv:cond-mat/0211246.

  12. Drag force and jet propulsion investigation of a swimming squid

    Directory of Open Access Journals (Sweden)

    Tabatabaei Mahdi

    2015-01-01

    Full Text Available In this study, CAD model of a squid was obtained by taking computer tomography images of a real squid. The model later placed into a computational domain to calculate drag force and performance of jet propulsion. The drag study was performed on the CAD model so that drag force subjected to real squid was revealed at squid’s different swimming speeds and comparison has been made with other underwater creatures (e.g., a dolphin, sea lion and penguin. The drag coefficient (referenced to total wetted surface area of squid is 0.0042 at Reynolds number 1.6x106 that is a %4.5 difference from Gentoo penguin. Besides, jet flow of squid was simulated to observe the flow region generated in the 2D domain utilizing dynamic mesh method to mimic the movement of squid’s mantle cavity.

  13. Current-phase relations and noise in rf biased SQUIDS

    International Nuclear Information System (INIS)

    Jackel, L.D.; Clark, T.D.; Buhrman, R.A.

    1975-01-01

    An investigation was made of the effect of the weak link current-phase relation on noise in rf biased SQUIDs. Non-sinusoidal current-phase relations were observed in various weak links, and these non-sinusoidal relations were correlated with significantly increased intrinsic noise in the SQUID ring. The current-phase relation was also found to affect the amplitude of the rf SQUID ring dissipation. The result of an rf SQUID system noise analysis shows that, due to increased intrinsic noise and reduced ring dissipation, the minimum attainable noise for a SQUID ring having a very non-sinusoidal current-phase relation is considerably greater than for a ring with a sinusoidal relation

  14. Factors affecting knowledge transfer from continuing professional education to clinical practice: Development and psychometric properties of a new instrument.

    Science.gov (United States)

    Vasli, Parvaneh; Dehghan-Nayeri, Nahid; Khosravi, Laleh

    2018-01-01

    Despite the emphasis placed on the implementation of continuing professional education programs in Iran, researchers or practitioners have not developed an instrument for assessing the factors that affect the knowledge transfer from such programs to clinical practice. The aim of this study was to design and validate such instrument for the Iranian context. The research used a three-stage mix method. In the first stage, in-depth interviews with nurses and content analysis were conducted, after which themes were extracted from the data. In the second stage, the findings of the content analysis and literature review were examined, and preliminary instrument options were developed. In the third stage, qualitative content validity, face validity, content validity ratio, content validity index, and construct validity using exploratory factor analysis was conducted. The reliability of the instrument was measured before and after the determination of construct validity. Primary tool instrument initially comprised 53 items, and its content validity index was 0.86. In the multi-stage factor analysis, eight questions were excluded, thereby reducing 11 factors to five and finally, to four. The final instrument with 43 items consists of the following dimensions: structure and organizational climate, personal characteristics, nature and status of professionals, and nature of educational programs. Managers can use the Iranian instrument to identify factors affecting knowledge transfer of continuing professional education to clinical practice. Copyright © 2017. Published by Elsevier Ltd.

  15. Scanning SQUID microscope with an in-situ magnetization/demagnetization field for geological samples

    Science.gov (United States)

    Du, Junwei; Liu, Xiaohong; Qin, Huafeng; Wei, Zhao; Kong, Xiangyang; Liu, Qingsong; Song, Tao

    2018-04-01

    Magnetic properties of rocks are crucial for paleo-, rock-, environmental-magnetism, and magnetic material sciences. Conventional rock magnetometers deal with bulk properties of samples, whereas scanning microscope can map the distribution of remanent magnetization. In this study, a new scanning microscope based on a low-temperature DC superconducting quantum interference device (SQUID) equipped with an in-situ magnetization/demagnetization device was developed. To realize the combination of sensitive instrument as SQUID with high magnetizing/demagnetizing fields, the pick-up coil, the magnetization/demagnetization coils and the measurement mode of the system were optimized. The new microscope has a field sensitivity of 250 pT/√Hz at a coil-to-sample spacing of ∼350 μm, and high magnetization (0-1 T)/ demagnetization (0-300 mT, 400 Hz) functions. With this microscope, isothermal remanent magnetization (IRM) acquisition and the according alternating field (AF) demagnetization curves can be obtained for each point without transferring samples between different procedures, which could result in position deviation, waste of time, and other interferences. The newly-designed SQUID microscope, thus, can be used to investigate the rock magnetic properties of samples at a micro-area scale, and has a great potential to be an efficient tool in paleomagnetism, rock magnetism, and magnetic material studies.

  16. ULF-NMR system using HTS-SQUID and permanent magnet

    Energy Technology Data Exchange (ETDEWEB)

    Fukumoto, Shohei, E-mail: hatukade@ens.tut.ac.jp [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan); Tsunaki, Shingo; Chigasaki, Takumi; Hatsukade, Yoshimi; Tanaka, Saburo [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2013-01-15

    Highlights: ► A permanent magnet was introduced into a ULF SQUID-NMR system for polarization. ► An instrument to transfer a sample in the magnet to under a SQUID was implemented. ► An AC pulse coil was also introduced to apply a π/2 pulse to obtain an NMR signal. ► A {sup 1}H NMR signal was measured while applying a static field of 45 μT. ► The signal to noise ratio of the {sup 1}H NMR signal was about 100. -- Abstract: We have constructed an ultra-low field (ULF) nuclear magnetic resonance (NMR)/magnetic resonance imaging (MRI) system using an HTS-rf-SQUID and room-temperature electromagnets in a magnetically shielded room (MSR). In this study, in order to improve the signal to noise ratio (S/N) of the system, we introduced a permanent magnet instead of the electromagnet for pre-polarizing the sample to enhance the pre-polarizing field (B{sub p}). The cylindrical permanent magnet of 270 mT was used to magnetize a water sample for several seconds outside the MSR and about 1.5 m away from the SQUID. We constructed an instrument to transfer the magnetized sample from the permanent magnet to under the SQUID in 0.5 s. Since the non-adiabatic condition cannot be kept in such sample transfer scheme, an AC pulse coil to apply an AC pulse field B{sub AC} to rotate the magnetization moments for π/2 was introduced to measure a free induction decay (FID) signal from the sample. By this system, we obtained an NMR signal from the water sample of 10 ml while applying a static field of 45 μT and π/2 pulse after the transfer. The S/N of the NMR spectrum was about 100 by a single shot, which was 10 times larger than that obtained with the electromagnet of 32 mT. In addition, we demonstrated the measurements of the longitudinal relaxation time (T{sub 1}) and the spin echo signal of the water sample by the system.

  17. An instrument to characterize the environment for residents' evidence-based medicine learning and practice.

    Science.gov (United States)

    Mi, Misa; Moseley, James L; Green, Michael L

    2012-02-01

    Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.

  18. Clinical practice guidelines for treatment of acne vulgaris: a critical appraisal using the AGREE II instrument.

    Science.gov (United States)

    Sanclemente, Gloria; Acosta, Jorge-Luis; Tamayo, Maria-Eulalia; Bonfill, Xavier; Alonso-Coello, Pablo

    2014-04-01

    A significant number of clinical practice guidelines (CPGs) about the treatment of acne vulgaris in adolescents and adults have been published worldwide. However, little is known about the quality of CPGs in this field. The aim of this study was to appraise the methodological quality of published acne vulgaris CPGs. We performed a systematic review of published CPGs on acne vulgaris therapy from July 2002 to July 2012. Three reviewers independently assessed each CPG using the AGREE II instrument. A standardized score was calculated for each of the six domains. Our search strategy identified 103 citations but just six met our inclusion criteria. Agreement among reviewers was very good: 0.981. The domains that scored better were: "scope and purpose" and "clarity and presentation". Those that scored worse were "stakeholder involvement", "rigor of development", and "applicability". The European and the Malaysian CPGs were the only recommended with no further modifications. In addition, the Mexican, Colombian and the United States guidelines were recommended with provisos, with lower scores regarding stakeholder involvement, rigor of development and applicability. Only two guidelines clearly reported outcome measures for evaluating efficacy or included quality of life outcomes. CPGs varied regarding the consideration of light/laser therapy or consideration of complementary/alternative medicines. None of them included cost considerations of drugs such as systemic isotretinoin. In conclusion, published acne vulgaris CPGs for acne therapy vary in quality with a clear need to improve their methodological rigor. This could be achieved with the adherence to current CPGs development standards.

  19. [Psychometric properties of an instrument to evaluate the nurse attitude towards good practice guides].

    Science.gov (United States)

    López-Díaz, Cristina; Fraille-Calle, Luis; Herrero-Rosado, Marta; Arnés-Muñoz, Vanessa; De-Dios-De-Dios, Teresa

    2016-01-01

    The Guides of Good Practices (GGP) are necessary tools in the universal healthcare and in the clinical management, providing the user/patient with a major quality in the assistance, in order to optimize and reinforce an individualized attention into action, taking into account the best scientific evidence. The literature provides different references to the development of the GGP, but there is little knowledge about the attitude of professionals towards them, since most of the studies that exist are qualitative. Therefore, the aim of this work is to construct and validate a Likert scale which could assess the attitude of the nurse towards GGP. The methodology used was quantitative, descriptive, cross, opinion, anonymous and also it could validate a scale via the following measurements: content validation by experts, correlation between items, external reliability, internal consistency, stability and exploratory factor analysis. The result was a scale consisting of 20 items that refer to the attitude toward the GGP, with a percentage of agreement among experts over 75 % on all the items, and a significant Pearson correlation between the pre-test and post-test in all variables, but for three. The internal consistency measured by Cronbach's alpha was 0.878. These results are acceptable in terms of the psychometric characteristics of the instrument, with easy and fast administration and simple in their interpretation, allowing quantifying and generating knowledge about the attitudes of nurses towards GGP.

  20. High speed non-latching squid binary ripple counter

    International Nuclear Information System (INIS)

    Silver, A.H.; Phillips, R.R.; Sandell, R.D.

    1985-01-01

    High speed, single flux quantum (SFQ) binary scalers are important components in superconducting analog-to-digital converters (ADC). This paper reviews the concept for a SQUID ADC and the design of an SFQ binary ripple counter, and reports the simulation of key components, and fabrication and performance of non-latching SQUID scalers and SFQ binary ripple counters. The SQUIDs were fabricated with Nb/Nb 2 O 5 /PbIn junctions and interconnected by monolithic superconducting transmission lines and isolation resistors. Each SQUID functioned as a bistable flip-flop with the input connected to the center of the device and the output across one junction. All junctions were critically damped to optimize the pulse response. Operation was verified by observing the dc I-V curves of successive SQUIDs driven by a cw pulse train generated on the same chip. Each SQUID exhibited constant-voltage current steps at 1/2 the voltage of the preceding device as expected from the Josephson voltage-to-frequency relation. Steps were observed only for the same voltage polarity of successive devices and for proper phase bias of the SQUID. Binary frequency division was recorded up to 40GHz for devices designed to operate to 28GHz

  1. Psychometrics of the preschooler physical activity parenting practices instrument among a Latino sample.

    Science.gov (United States)

    O'Connor, Teresia M; Cerin, Ester; Hughes, Sheryl O; Robles, Jessica; Thompson, Deborah I; Mendoza, Jason A; Baranowski, Tom; Lee, Rebecca E

    2014-01-15

    Latino preschoolers (3-5 year old children) have among the highest rates of obesity. Low levels of physical activity (PA) are a risk factor for obesity. Characterizing what Latino parents do to encourage or discourage their preschooler to be physically active can help inform interventions to increase their PA. The objective was therefore to develop and assess the psychometrics of a new instrument: the Preschooler Physical Activity Parenting Practices (PPAPP) among a Latino sample, to assess parenting practices used to encourage or discourage PA among preschool-aged children. Cross-sectional study of 240 Latino parents who reported the frequency of using PA parenting practices. 95% of respondents were mothers; 42% had more than a high school education. Child mean age was 4.5 (±0.9) years (52% male). Test-retest reliability was assessed in 20%, 2 weeks later. We assessed the fit of a priori models using Confirmatory factor analyses (CFA). In a separate sub-sample (35%), preschool-aged children wore accelerometers to assess associations with their PA and PPAPP subscales. The a-priori models showed poor fit to the data. A modified factor structure for encouraging PPAPP had one multiple-item scale: engagement (15 items), and two single-items (have outdoor toys; not enroll in sport-reverse coded). The final factor structure for discouraging PPAPP had 4 subscales: promote inactive transport (3 items), promote screen time (3 items), psychological control (4 items) and restricting for safety (4 items). Test-retest reliability (ICC) for the two scales ranged from 0.56-0.85. Cronbach's alphas ranged from 0.5-0.9. Several sub-factors correlated in the expected direction with children's objectively measured PA. The final models for encouraging and discouraging PPAPP had moderate to good fit, with moderate to excellent test-retest reliabilities. The PPAPP should be further evaluated to better assess its associations with children's PA and offers a new tool for measuring PPAPP

  2. Antioxidant and antimicrobial activities of squid ink powder

    Directory of Open Access Journals (Sweden)

    Fatimah Zaharah, M.Y.

    2017-10-01

    Full Text Available Economic development in Malaysia has led to increasing quantity and complexity of generated waste or by-product. The main objective of this study is to investigate the antioxidant and antimicrobial activities of squid ink powder. The squid ink was collected from fresh squid and dried using freeze dryer before it was ground into powder. The yield of squid ink was 22.82% after freeze-drying which was 69.37g in amount. Proximate composition analysis as well as two total antioxidant activity assays named 2,2-diphenyl-1-picrylhydrazyl (DPPH assay and Ferric Reducing Antioxidant Power (FRAP assay, and antimicrobial analysis were done on the powdered squid ink. The proximate results of squid ink powder were 4.43 ± 0.29% moisture, 62.46 ± 0.62% protein, 3.96 ± 0.08% fat, and 9.29 ± 0.05% ash. Results of DPPH assay showed that water extraction of squid ink powder has the highest 94.87 ± 4.87%, followed by ethanol 67.57 ± 7.55%, and hexane extract 2.10 ± 1.18%. FRAP assay result presented the same trend with water extraction had the highest value of 929.67 ± 2.31 μmol Fe (II / g of sample extract, followed by ethanol extract 201.00 ± 26.29 μmol Fe (II per gram sample and hexane 79.67 ± 12.66 μmol Fe (II / g of sample extract. Both water and ethanol extract showed antimicrobial properties with inhibition range of 7 to 15 mm, respectively. Fresh squid ink had 1.254 × 103 colony forming unit per gram of sample of microbial content. Squid ink powder had protein as major compound and microbial content was below from standard value of fisheries products as stated in Food Act 1983 and Regulation 1985.

  3. Development and Analysis of an Instrument to Assess Student Understanding of GOB Chemistry Knowledge Relevant to Clinical Nursing Practice

    Science.gov (United States)

    Brown, Corina E.; Hyslop, Richard M.; Barbera, Jack

    2015-01-01

    The General, Organic, and Biological Chemistry Knowledge Assessment (GOB-CKA) is a multiple-choice instrument designed to assess students' understanding of the chemistry topics deemed important to clinical nursing practice. This manuscript describes the development process of the individual items along with a psychometric evaluation of the…

  4. Standard practice of calibration of force-measuring instruments for verifying the force indication of testing machines

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 The purpose of this practice is to specify procedures for the calibration of force-measuring instruments. Procedures are included for the following types of instruments: 1.1.1 Elastic force-measuring instruments, and 1.1.2 Force-multiplying systems, such as balances and small platform scales. Note 1Verification by deadweight loading is also an acceptable method of verifying the force indication of a testing machine. Tolerances for weights for this purpose are given in Practices E 4; methods for calibration of the weights are given in NIST Technical Note 577, Methods of Calibrating Weights for Piston Gages. 1.2 The values stated in SI units are to be regarded as the standard. Other metric and inch-pound values are regarded as equivalent when required. 1.3 This practice is intended for the calibration of static force measuring instruments. It is not applicable for dynamic or high speed force calibrations, nor can the results of calibrations performed in accordance with this practice be assumed valid for...

  5. Development and validation of Dutch version of Lasater Clinical Judgment Rubric in hospital practice: An instrument design study

    NARCIS (Netherlands)

    Vreugdenhil, Jettie; Spek, Bea

    2017-01-01

    Clinical reasoning in patient care is a skill that cannot be observed directly. So far, no reliable, valid instrument exists for the assessment of nursing students' clinical reasoning skills in hospital practice. Lasater's clinical judgment rubric (LCJR), based on Tanner's model "Thinking like a

  6. Identifying crime victims who are at high risk for post traumatic stress disorder: developing a practical referral instrument

    NARCIS (Netherlands)

    Wohlfarth, T.; Winkel, F. W.; van den Brink, W.

    2002-01-01

    Objective To construct a practical instrument for the identification and referral of crime victims who are at high risk for post traumatic stress disorder (PTSD). Method: Crime victims filing a complaint at a police station were asked to fill out a questionnaire probing risk factors for PTSD (n

  7. Development and validation of an international appraisal instrument for assessing the quality of clinical practice guidelines: the AGREE project.

    Science.gov (United States)

    2003-02-01

    International interest in clinical practice guidelines has never been greater but many published guidelines do not meet the basic quality requirements. There have been renewed calls for validated criteria to assess the quality of guidelines. To develop and validate an international instrument for assessing the quality of the process and reporting of clinical practice guideline development. The instrument was developed through a multi-staged process of item generation, selection and scaling, field testing, and refinement procedures. 100 guidelines selected from 11 participating countries were evaluated independently by 194 appraisers with the instrument. Following refinement the instrument was further field tested on three guidelines per country by a new set of 70 appraisers. The final version of the instrument contained 23 items grouped into six quality domains with a 4 point Likert scale to score each item (scope and purpose, stakeholder involvement, rigour of development, clarity and presentation, applicability, editorial independence). 95% of appraisers found the instrument useful for assessing guidelines. Reliability was acceptable for most domains (Cronbach's alpha 0.64-0.88). Guidelines produced as part of an established guideline programme had significantly higher scores on editorial independence and, after the publication of a national policy, had significantly higher quality scores on rigour of development (pinternationally. The instrument is sensitive to differences in important aspects of guidelines and can be used consistently and easily by a wide range of professionals from different backgrounds. The adoption of common standards should improve the consistency and quality of the reporting of guideline development worldwide and provide a framework to encourage international comparison of clinical practice guidelines.

  8. Artificial intelligence for enhancing energy efficiency. Fundamentals, instruments, practice; Kuenstliche Intelligenz zur Steigerung der Energie-Effizienz. Grundlagen, Instrumente, Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Brammer, R.

    2006-07-01

    In a time of rising energy prices and a growing field for information technology, its worth to take a glance of how to combine the two fields of energy efficiency and artificial intelligence. Aim of this combination is to support human beings in their energy consuming habits and to adjust the usage to the individual requirement. An artificial intelligence today is able to mine data, plan actions and make decisions on a rational basis. Thus an intelligent agent can help to lower energy wastage by controlling and regulating a heating system. For this application only few sensors and a control for the heating power are sufficient to support the artificial intelligence with enough information about its environment and enough actuators to manipulate it. On the basis of the collected information the software is able to deduce knowledge, which in turn is stored in a database for later access. This knowledge is used to take in states, which consume less heating power by still keeping the temperature on the same level. Because the acceptance by the user, next to saving energy, is the prime target of the artificial intelligence, its success is measured on how little intervention by humans occur. With the help of probability and benefit based algorithms, several training runs before the applied operation and given performance standard the software is able to reduce calculating times to practicables times. Considering the application possibilities given in this thesis, it is feasible to devolve the use of artificial intelligence and its ability to save energy for many different process controls. (orig.)

  9. A SQUID Bootstrap Circuit with a Large Parameter Tolerance

    International Nuclear Information System (INIS)

    Zhang Guo-Feng; Kong Xiang-Yan; Xie Xiao-Ming; Zhang Yi; Krause Hans-Joachim; Offenhäusser Andreas

    2013-01-01

    The voltage biased (SQUID) bootstrap circuit (SBC) was recently introduced as an effective means to reduce the preamplifier noise contribution. We analyze the tolerances of the SBC noise suppression performance to spreads in SQUID and SBC circuit parameters. It is found that the tolerance to spread mainly caused by the integrated circuit fabrication process could be extended by a one-time adjustable current feedback. A helium-cooled niobium SQUID with a loop inductance of 350 pH is employed to experimentally verify the analysis. From this work, design criteria for fully integrated SBC devices with a high yield can be derived

  10. SQUIDs in thermal detectors of weakly interacting particles

    International Nuclear Information System (INIS)

    Trofimov, V.N.

    1991-01-01

    The application of four different types of SQUID-assisted thermometers for cryogenic thermal detectors of weakly interacting particles is analyzed with two of them for the first time. The classic resistive thermometer is considered as well for the comparison. Original results of testing the detector with working temperature of 1K and thermocouple thermometer with SQUID are given. The conclusion is made that temperature resolution of 10 -10 kHz -1/2 or energy sensitivity of 1-10 eV per 1 kg of detector mass can be achieved when using the SQUID-assisted thermometers. 12 refs.; 7 figs.; 1 tab

  11. Microwave SQUID multiplexer demonstration for cosmic microwave background imagers

    Science.gov (United States)

    Dober, B.; Becker, D. T.; Bennett, D. A.; Bryan, S. A.; Duff, S. M.; Gard, J. D.; Hays-Wehle, J. P.; Hilton, G. C.; Hubmayr, J.; Mates, J. A. B.; Reintsema, C. D.; Vale, L. R.; Ullom, J. N.

    2017-12-01

    Key performance characteristics are demonstrated for the microwave superconducting quantum interference device (SQUID) multiplexer (μmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the μmux produces a white, input referred current noise level of 29 pA/ √{H z } at a microwave probe tone power of -77 dB, which is well below the expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98 pA/ √{H z } in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ˜100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the μmux as a viable readout technique for future CMB imaging instruments.

  12. Microwave SQUID Multiplexer Demonstration for Cosmic Microwave Background Imagers.

    Science.gov (United States)

    Dober, B; Becker, D T; Bennett, D A; Bryan, S A; Duff, S M; Gard, J D; Hays-Wehle, J P; Hilton, G C; Hubmayr, J; Mates, J A B; Reintsema, C D; Vale, L R; Ullom, J N

    2017-12-01

    Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.

  13. Development of non-destructive evaluation system using an HTS-SQUID gradiometer for magnetized materials

    Science.gov (United States)

    Kawano, J.; Tsukamoto, A.; Adachi, S.; Oshikubo, Y.; Hato, T.; Tanabe, K.; Okamura, T.

    We have developed a new eddy-current non-destructive evaluation (NDE) system using an HTS SQUID gradiometer with the aim of applying it to practical materials with magnetization. The new NDE system employs a LN2-cooled external Cu pickup coil and an HTS SQUID chip placed in a magnetic shield made of HTS material. The HTS SQUID chip consists of an HTS planar gradiometer manufactured by using a ramp-edge junction technology and a multi-turn HTS thin film input coil coupled with the flip-chip configuration. The first-order coaxial gradiometric Cu pickup coil with a diameter of 16 mm and the baseline of 5.6 mm was used in the present NDE experiments. By using this NDE system, we could observe defect-induced magnetic signals without an appreciable influence of magnetization up to 10 mT. We also examined the ability of detecting deep-lying defects and compared with the results obtained using our previous NDE system.

  14. Field estimation of soil water content. A practical guide to methods, instrumentation and sensor technology

    International Nuclear Information System (INIS)

    2008-01-01

    During a period of five years, an international group of soil water instrumentation experts were contracted by the International Atomic Energy Agency to carry out a range of comparative assessments of soil water sensing methods under laboratory and field conditions. The detailed results of those studies are published elsewhere. Most of the devices examined worked well some of the time, but most also performed poorly in some circumstances. The group was also aware that the choice of a water measurement technology is often made for economic, convenience and other reasons, and that there was a need to be able to obtain the best results from any device used. The choice of a technology is sometimes not made by the ultimate user, or even if it is, the main constraint may be financial rather than technical. Thus, this guide is presented in a way that allows the user to obtain the best performance from any instrument, while also providing guidance as to which instruments perform best under given circumstances. That said, this expert group of the IAEA reached several important conclusions: (1) the field calibrated neutron moisture meter (NMM) remains the most accurate and precise method for soil profile water content determination in the field, and is the only indirect method capable of providing accurate soil water balance data for studies of crop water use, water use efficiency, irrigation efficiency and irrigation water use efficiency, with a minimum number of access tubes; (2) those electromagnetic sensors known as capacitance sensors exhibit much more variability in the field than either the NMM or direct soil water measurements, and they are not recommended for soil water balance studies for this reason (impractically large numbers of access tubes and sensors are required) and because they are rendered inaccurate by changes in soil bulk electrical conductivity (including temperature effects) that often occur in irrigated soils, particularly those containing

  15. rf SQUID system as tunable flux qubit

    Energy Technology Data Exchange (ETDEWEB)

    Ruggiero, B. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy)]. E-mail: b.ruggiero@cib.na.cnr.it; Granata, C. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Vettoliere, A. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Rombetto, S. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Russo, R. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Russo, M. [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Corato, V. [Dipartimento di Ingegneria dell' Informazione, Seconda Universita di Napoli, I-81031 Aversa (Italy); Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy); Silvestrini, P. [Dipartimento di Ingegneria dell' Informazione, Seconda Universita di Napoli, I-81031 Aversa (Italy); Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, I-80078 Pozzuoli (Italy)

    2006-08-21

    We present a fully integrated rf SQUID-based system as flux qubit with a high control of the flux transfer function of the superconducting transformer modulating the coupling between the flux qubit and the readout system. The control of the system is possible by including into the superconducting flux transformer a vertical two-Josephson-junctions interferometer (VJI) in which the Josephson current is precisely modulated from a maximum to zero by a transversal magnetic field parallel to the flux transformer plane. The proposed system can be also used in a more general configuration to control the off-diagonal terms in the Hamiltonian of the flux qubit and to turn on and off the coupling between two or more qubits.

  16. A View of Current Evaluative Practices in Instrumental Music Teacher Education

    Science.gov (United States)

    Peterson, Amber Dahlén

    2014-01-01

    The purpose of this study was to examine how instrumental music educator skills are being evaluated in current undergraduate programs. While accrediting organizations mandate certain elements of these programs, they provide limited guidance on what evaluative approaches should be used. Instrumental music teacher educators in the College Music…

  17. Can understanding squid life-history strategies and recruitment ...

    African Journals Online (AJOL)

    Can understanding squid life-history strategies and recruitment improve management? ... range of potentially limiting conditions in different years, they store genetic diversity and stabilize recruitment in time. ... AJOL African Journals Online.

  18. Negative inductance SQUID qubit operating in a quantum regime

    Science.gov (United States)

    Liu, W. Y.; Su, F. F.; Xu, H. K.; Li, Z. Y.; Tian, Ye; Zhu, X. B.; Lu, Li; Han, Siyuan; Zhao, S. P.

    2018-04-01

    Two-junction SQUIDs with negative mutual inductance between their two arms, called nSQUIDs, have been proposed for significantly improving quantum information transfer but their quantum nature has not been experimentally demonstrated. We have designed, fabricated, and characterized superconducting nSQUID qubits. Our results provide clear evidence of the quantum coherence of the device, whose properties are well described by theoretical calculations using parameters determined from spectroscopic measurement. In addition to their future application for fast quantum information transfer, the nSQUID qubits exhibit rich characteristics in their tunable two-dimensional (2D) potentials, energy levels, wave function symmetries, and dipole matrix elements, which are essential to the study of a wide variety of macroscopic quantum phenomena such as tunneling in 2D potential landscapes.

  19. Reactive probing of macroscopically quantum mechanical SQUID rings

    International Nuclear Information System (INIS)

    Prance, R.J.; Clark, T.D.; Whiteman, R.; Diggins, J.; Ralph, J.F.; Prance, H.; Spiller, T.P.; Widom, A.; Srivastava, Y.

    1994-01-01

    In this paper we demonstrate that the energy level structure of ultra small capacitance SQUID rings can be probed adiabatically at radio frequency using both dynamical and quasistatic reactive techniques. ((orig.))

  20. Gear Selectivity of a Longfin Squid Bottom Trawl

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Loligo pealeii (longfin inshore squid) co-occurs with Atlantic butterfish (Peprilus triacanthus) throughout the year and discarding in the L. pealeii bottom trawl...

  1. Forecasting chokka squid Loligo vulgaris reynaudii catches and ...

    African Journals Online (AJOL)

    spamer

    2017-11-11

    Nov 11, 2017 ... on ambient water temperature (Augustyn et al. 1992,. A. Oosthuisen, University of ..... from tagged squid and the supply of continuous environ- mental data. ... should a leak develop, and to provide insulation for the electronics.

  2. Dc-SQUID sensor system for multichannel neuromagnetometry

    Energy Technology Data Exchange (ETDEWEB)

    Houwman, E.P.; Veldhuis, D.; Flokstra, ter Brake, H.J.M.; Jaszczuk, W.; Rogalla, H. (Univ. of Twente, Faculty of Applied Physics, P.O. Box 217, 7500 AE Enschede (NL)); Martinez, A. (Universidad de Zaragoza, E.T.S.I.I. Maria Zambrano 50, 50015 Zaragoza (ES))

    1991-03-01

    This paper reports on various DC-SQUID sensor configurations developed for use in the authors' 19-channel neuromagetometer. Apart from the standard type, resistively and indictively shunted SQUIDs were made, allowing for a large screening factor {beta} ({gt}1). In this way signal coupling from the pick-up coil to the SQUID is facilitated and capactive coupling between the input coil and the SQUID washer can be decreased. The number of turns of the input coil is decreased further by allowing for an inductance mismatch in the input circuit. Although theoretically both measures give rise to an increased field noise of the sensor, they may lead to a reduction of the excess noise and the noise balance may become positive.

  3. Symposium on applications of superconducting quantum interference devices (SQUIDS)

    International Nuclear Information System (INIS)

    1978-01-01

    The abstracts are given of thirteen papers presented at a ''SQUID Symposium'' organized by the Division of Materials Sciences of the U.S. Department of Energy and held March 23--25, 1978, at the University of Virginia. Since SQUID systems have already been utilized in feasibility demonstration in geothermal reservoir exploration, it was recognized that these devices also hold great potential for many other important scientific measurements. Many of these are energy-related, and others include forefront investigations in a diverse group of scientific areas, from biomedical to earthquake monitoring. Research in SQUIDs has advanced so rapidly in recent years that it was felt that a symposium to review the current status and future prospects of the devices would be timely. The abstracts given present an overview of work in this area and hopefully provide an opportunity to increase awareness among basic and applied scientists of the inherent implications of the extreme measurement sensitivity in advanced SQUID systems

  4. High-performance DC SQUIDs with submicrometer niobium Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    de Waal, V.J.; Klapwijk, T.M.; van den Hamer, P.

    1983-11-01

    We report on the fabrication and performance of low-noise, all-niobium, thin-film planar dc SQUIDs with submicrometer Josephson junctions. The junctions are evaporated obliquely through a metal shadow evaporation mask, which is made using optical lithography with 0.5 ..mu..m tolerance. The Josephson junction barrier is formed by evaporating a thin silicon film and with a subsequent oxidation in a glow discharge. The junction parameters can be reproduced within a factor of two. Typical critical currents of the SQUIDs are about 3 ..mu..A and the resistances are about 100 ..cap omega... With SQUIDs having an inductance of 1 nH the voltage modulation is a least 60 ..mu..V. An intrinsic energy resolution of 4 x 10/sup -32/ J/Hz has been reached. The SQUIDs are coupled to wire-wound input coils or with thin-film input coils. The thin-film input coil consists of a niobium spiral of 20 turns on a separate substrate. In both cases the coil is glued onto a 2-nH SQUID with a coupling efficiency of at least 0.5. Referred to the thin-film input coil, the best coupled energy resolution achieved is 1.2 x 10/sup -30/ J/Hz measured in a flux-locked loop at frequencies above 10 Hz. As far as we know, this is the best figure achieved with an all-refractory-metal thin-film SQUID. The fabrication technique used is suited for making circuits with SQUID and pickup coil on the same substrate. We describe a compact, planar, first-order gradiometer integrated with a SQUID on a single substrate. The gradient noise of this device is 3 x 10/sup -12/ Tm/sup -1/. The gradiometer has a size of 12 mm x 17 mm, is simple to fabricate, an is suitable for biomedical applications.

  5. High-performance dc SQUIDs with submicrometer niobium Josephson junctions

    Science.gov (United States)

    de Waal, V. J.; Klapwijk, T. M.; van den Hamer, P.

    1983-11-01

    We report on the fabrication and performance of low-noise, all-niobium, thin-film planar dc SQUIDs with submicrometer Josephson junctions. The junctions are evaporated obliquely through a metal shadow evaporation mask, which is made using optical lithography with 0.5 µm tolerance. The Josephson junction barrier is formed by evaporating a thin silicon film and with a subsequent oxidation in a glow discharge. The junction parameters can be reproduced within a factor of two. Typical critical currents of the SQUIDs are about 3 µA and the resistances are about 100 Ω. With SQUIDs having an inductance of 1 nH the voltage modulation is at least 60 µV. An intrinsic energy resolution of 4×10-32 J/Hz has been reached. The SQUIDs are coupled to wire-wound input coils or with thin-film input coils. The thin-film input coil consists of a niobium spiral of 20 turns on a separate substrate. In both cases the coil is glued onto a 2-nH SQUID with a coupling efficiency of at least 0.5. Referred to the thin-film input coil, the best coupled energy resolution achieved is 1.2×10-30 J/Hz measured in a flux-locked loop at frequencies above 10 Hz. As far as we know, this is the best figure achieved with an all-refractory-metal thin-film SQUID. The fabrication technique used is suited for making circuits with SQUID and pickup coil on the same substrate. We describe a compact, planar, first-order gradiometer integrated with a SQUID on a single substrate. The gradient noise of this device is 3×10-12 T m-1. The gradiometer has a size of 12 mm×17 mm, is simple to fabricate, and is suitable for biomedical applications.

  6. Characterization of thermal aging of duplex stainless steel by SQUID

    International Nuclear Information System (INIS)

    Isobe, Y.; Kamimura, A.; Aoki, K.; Nakayasu, F.

    1995-01-01

    Thermal aging is a growing concern for long-term-aged duplex stainless steel piping in nuclear power plants. Superconducting QUantum Interference Device (SQUID) was used for the detection of thermal aging of SUS329 rolled duplex stainless steel and SCS16 cast duplex stainless steel. It was found that the SQUID output signal pattern in the presence of AC magnetic field applied to the specimen was sensitive to the changes in electromagnetic properties due to thermal aging

  7. Nb nanoSQUIDs for detection of small spin systems

    Energy Technology Data Exchange (ETDEWEB)

    Woelbing, R.; Nagel, J.; Kemmler, M.; Kleiner, R.; Koelle, D. [Physikalisches Institut, Universitaet Tuebingen (Germany); Kieler, O.; Weimann, T.; Kohlmann, J.; Zorin, A. [Fachbereich 2.4 ' ' Quantenelektronik' ' , PTB Braunschweig (Germany); Buchter, A.; Xue, F.; Poggio, M. [Department of Physics, University of Basel (Switzerland); Rueffer, D.; Russo-Averchi, E.; Fontcuberta i Morral, A. [Laboratoire des Materiaux Semiconducteurs, EPF Lausanne (Switzerland); Huber, R.; Berberich, P. [Physik-Department E10, Technische Universitaet Muenchen (Germany); Grundler, D. [Laboratoire des Materiaux Semiconducteurs, EPF Lausanne (Switzerland); Physik-Department E10, Technische Universitaet Muenchen (Germany)

    2013-07-01

    We report on the realization of highly sensitive dc nanoSQUIDs for the investigation of small spin systems in moderate magnetic fields. The Nb SQUIDs are based on normal metal Josephson junctions made of HfTi and patterned by e-beam lithography. We demonstrate stable operation up to B = ± 50 mT without degradation of rms flux noise (S{sub Φ}{sup 1/2} ≤ 280 nΦ{sub 0}/√(Hz)). We also present a multifunctional system combining a Nb nanoSQUID and a low-temperature magnetic force microscope (LTMFM) with a Ni nanotube as a scanning tip. This system allows for magnetization measurements of the Ni tube by using both, LTMFM and SQUID readout. Furthermore, the measurement of magnetic flux Φ vs. position of the particle provides an experimental determination of the coupling factor φ{sub μ} = Φ/μ between SQUID and Ni tube with magnetic moment μ. The results confirm our predictions from numerical simulations, taking into account the SQUID geometry.

  8. Practicing a musical instrument in childhood is associated with enhanced verbal ability and nonverbal reasoning.

    Science.gov (United States)

    Forgeard, Marie; Winner, Ellen; Norton, Andrea; Schlaug, Gottfried

    2008-01-01

    In this study we investigated the association between instrumental music training in childhood and outcomes closely related to music training as well as those more distantly related. Children who received at least three years (M = 4.6 years) of instrumental music training outperformed their control counterparts on two outcomes closely related to music (auditory discrimination abilities and fine motor skills) and on two outcomes distantly related to music (vocabulary and nonverbal reasoning skills). Duration of training also predicted these outcomes. Contrary to previous research, instrumental music training was not associated with heightened spatial skills, phonemic awareness, or mathematical abilities. While these results are correlational only, the strong predictive effect of training duration suggests that instrumental music training may enhance auditory discrimination, fine motor skills, vocabulary, and nonverbal reasoning. Alternative explanations for these results are discussed.

  9. Design and quality assurance of control and instrumentation systems, licensing practice in Austria

    International Nuclear Information System (INIS)

    Fasko, Peter.

    1978-01-01

    The practicised way how licensing of control and instrumentation systems is performed in Austria, is related. As there is no national regulations in Austria for licensing nuclear power plants, it tries to adopt international regulations for its own purpose. (author)

  10. [German translation of Suicidal Patient Observation Chart (SPOC) - an instrument for practice].

    Science.gov (United States)

    Löhr, Michael; Schulz, Michael; Hemkendreis, Bruno; Björkdahl, Anna; Nienaber, André

    2013-12-01

    Nursing of suicidal in-patients is a complex and responsible task. A direct and immediate intensive caring and therapeutic supervision, also known as special observation is still recommended in guidelines (DGPPN, 2012) and maybe one of the most used interventions in the caring of suicidal patients in inpatient settings. It involves many kinds to develop the relationship between the observer and the patient. The original SPOC was developed in Sweden with the aim to increase the quality of a systematically documentation during the supervision of suicidal patients. It is an instrument to ensure systematic documentation of observational behavior or noticeable mood during acute suicidal crisis, for example feelings like "worried, anxious" or other possible influencing factors like "sudden mood variation". By this means the SPOC can ensure the process of systematic documentation of special observation and increase its quality, i. e. who documented what at what time. Furthermore SPOC can facilitate a better communication of the observation process to the multidisciplinary team and to the patient as well. The SPOC includes the 28 items and covers 24 separate observation periods. The aim of this paper is to constitute the translation process from the English to the German SPOC version. The translation process followed a five step model. In the first step the English version was translated from two German native speakers. In the second step, the first two translation results where discussed by the Expert group (authors) and a new version was developed. In the third step the first german version was translated back (two English native Speakers) into English. The fourth step was taken, to review the results by the expert groups (authors) and set up the so called "pre version". The last step includes the proof of content validity by 52 nurses. The proof was able to identify a few misunderstandings and helped to enhance the tool in its final version. With the translation, the

  11. Squids, snakes, and polarimeters: A new technique for measuring the magnetic moments of polarized beams

    International Nuclear Information System (INIS)

    Cameron, P.R.; Luccio, A.U.; Shea, T.J.; Tsoupas, N.; Goldberg, D.A.

    1997-01-01

    Effective polarimetry at high energies in hadron and lepton synchrotrons has been a long-standing and difficult problem. In synchrotrons with polarized beams it is possible to cause the direction of the polarization vector of a given bunch to alternate at a frequency which is some subharmonic of the rotation frequency. This can result in the presence of lines in the beam spectrum which are due only to the magnetic moment of the beam and which are well removed from the various lines due to the charge of the beam. The magnitude of these lines can be calculated from first principles. They are many orders of magnitude weaker than the Schottky signals. Measurement of the magnitude of one of these lines would be an absolute measurement of beam polarization. For measuring magnetic field, the Superconducting Quantum Interference Device, or squid, is about five orders of magnitude more sensitive than any other transducer. Using a squid, such a measurement might be accomplished with the proper combination of shielding, pickup loop design, and filtering. The resulting instrument would be fast, non-destructive, and comparatively cheap. In addition, techniques developed in the creation of such an instrument could be used to measure the Schottky spectrum in unprecedented detail. We present specifics of a polarimeter design for the Relativistic Heavy Ion Collider (RHIC) and briefly discuss the possibility of using this technique to measure polarization at high-energy electron machines like LEP and HERA. copyright 1997 American Institute of Physics

  12. The low fault HTSL-SQUID cooling system. Final report; Stoerarmes HTSL-SQUID-Kuehlsystem. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Binneberg, A.; Spoerl, G.; Buschmann, H.

    1997-03-01

    In the context of the research project, work was done for HTSL-SQUID on (1) the development of a thermo-siphon cooler (low fault and continuously working) and (2) the development of a latent storage cooler (low fault and discontinuously working). Two development versions of the latent storage cooler were followed up, the development of a spherical latent storage cooler and the development of an annular vessel latent storage cooler. A further precondition for the construction of the cooler was the use of split Stirling refrigerators as units producing the cold. The experimental sample was built up with refrigerators which could produce a nominal cooling output of 1.2 W at 80 K. Two samples of the thermo-siphon cooler were built, tested and improved. The second sample was developed further as a demonstration model, introduced at meetings and prepared for testing the cooling of HTSL-SQUIDs. The thermo-siphon cooler can be designed for cooling output up to about 2 W at 80 K and can be used controlled for a temperature range of 90 K to 66 K. (orig./MM) [Deutsch] Im Rahmen des Forschungsvorhabens wurde fuer HTSL-SQUID`s an der (1) Entwicklung eines Thermosiphon-Kuehlers (stoerarm und kontinuierlich arbeitend) und (2) Entwicklung eines Latentspeicher-Kuehlers (stoerfrei und diskontinuierlich arbeitend) gearbeitet. Bei dem Latentspeicher-Kuehler wurden zwei Entwicklungsversionen verfolgt, und zwar Entwicklung eines Kugel-Latentspeicher-Kuehlers und Entwicklung eines Ringgefaess-Latentspeicher-Kuehlers. Eine weitere Praemisse zum Aufbau der Kuehler war der Einsatz von Split-Stirling-Kaeltemaschinen als kaelteerzeugende Baugruppe. Die Versuchsmuster wurden mit Kaeltemaschinen aufgebaut, die eine Nennkuehlleistung von 1,2 W bei 80 K erzeugen konnten. Der Thermosiphon-Kuehler wurde in zwei Musterexemplaren aufgebaut, erprobt und verbessert. Das Zweitmuster wurde als Demonstrator weiterentwickelt, zu Fachtagungen vorgestellt und zur Testung der Kuehlung von HTSL-SQUIDs

  13. Model of practical skill performance as an instrument for supervision and formative assessment

    DEFF Research Database (Denmark)

    Nielsen, Carsten; Sommer, Irene; Larsen, Karin

    2012-01-01

    as during practice, performance and formative assessment of practical skills learning. It provided a common language about practical skills and enhanced the participants’ understanding of professionalism in practical nursing skill. In conclusion, the model helped to highlight the complexity in mastering......There are still weaknesses in the practical skills of newly graduated nurses. There is also an escalating pressure on existing clinical placements due to increasing student numbers and structural changes in health services. Innovative educational practices and the use of tools that might support...... learning are sparsely researched in the field of clinical education for nursing students. This paper reports on an action research study that promoted and investigated use of The Model of Practical Skill Performance as a learning tool during nursing students’ clinical placement. Clinical supervisors...

  14. Measurements of the dynamic input impedance of a dc SQUID

    International Nuclear Information System (INIS)

    Hilbert, C.; Clarke, J.

    1985-01-01

    The impedance of a circuit coupled magnetically via a mutual inductance M/sub i/ to a dc SQUID of geometric inductance L is modified by the dynamic input impedance of the SQUID, which can be characterized by the flux-to-current transfer function J/sub Phi/approx. =partialJ/partialPhi; J is the current circulating in the SQUID loop and ∫ is the flux applied to the loop. At the same time, the SQUID is modified by the presence of the input circuit in the lumped circuit approximation, one expects its inductance to be reduced to L'(1-α/sub e/ 2 )L, where α/sub e/ is an effective coupling coefficient. Calculations of J/sub Phi/ using an analog simulator are described and presented in the form of a dynamic inductance L and a dynamic resistance R versus bias current I and Phi. Experimental measurements of L and R were made on a planar, thin-film SQUID tightly coupled to a spiral input coil that was connected in series with a capacitor C/sub i/ to form a resonant circuit. Thus, J/sub Phi/ was determined from the change in the resonant frequency and quality factor of this circuit as a function of I and Phi. At low bias currents (low Josephson frequencies) the measured values of L were in reasonable agreement with values simulated for the reduced SQUID, while at higher bias currents (higher Josephson frequencies) the measured values were in better agreement with values simulated for the unscreened SQUID. Similar conclusions were reached in the comparison of the experimental and simulated values of the flux-to-voltage transfer function V/sub Phi/

  15. Nuclear magnetic resonance experiments with dc SQUID amplifiers

    International Nuclear Information System (INIS)

    Heaney, M.B.

    1990-11-01

    The development and fabrication of dc SQUIDs (Superconducting QUantum Interference Devices) with Nb/Al 2 O 3 /Nb Josephson junctions is described. A theory of the dc SQUID as a radio-frequency amplifier is presented, with an optimization strategy that accounts for the loading and noise contributions of the postamplifier and maximizes the signal-to-noise ratio of the total system. The high sensitivity of the dc SQUID is extended to high field NMR. A dc SQUID is used as a tuned radio-frequency amplifier to detect pulsed nuclear magnetic resonance at 32 MHz from a metal film in a 3.5 Tesla static field. A total system noise temperature of 11 K has been achieved, at a bath temperature of 4.2 K. The minimum number of nuclear Bohr magnetons observable from a free precession signal after a single pulse is about 2 x 10 17 in a bandwidth of 25 kHz. In a separate experiment, a dc SQUID is used as a rf amplifier in a NQR experiment to observe a new resonance response mechanism. The net electric polarization of a NaClO 3 crystal due to the precessing electric quadrupole moments of the Cl nuclei is detected at 30 MHz. The sensitivity of NMR and NQR spectrometers using dc SQUID amplifiers is compared to the sensitivity of spectrometers using conventional rf amplifiers. A SQUID-based spectrometer has a voltage sensitivity which is comparable to the best achieved by a FET-based spectrometer, at these temperatures and operating frequencies

  16. SQUID use for Geophysics: finding billions of dollars

    Science.gov (United States)

    Foley, Catherine

    2014-03-01

    Soon after their discovery, Jim Zimmerman saw the potential of using Superconducting Quantum Interference Devices, SQUIDs, for the study of Geophysics and undertook experiments to understand the magnetic phenomena of the Earth. However his early experiments were not successful. Nevertheless up to the early 1980's, some research effort in the use of SQUIDs for geophysics continued and many ideas of how you could use SQUIDs evolved. Their use was not adopted by the mining industry at that time for a range of reasons. The discovery of high temperature superconductors started a reinvigoration in the interest to use SQUIDs for mineral exploration. Several groups around the world worked with mining companies to develop both liquid helium and nitrogen cooled systems. The realisation of the achievable sensitivity that contributed to successful mineral discoveries and delineation led to real financial returns for miners. By the mid 2000's, SQUID systems for geophysics were finally being offered for sale by several start-up companies. This talk will tell the story of SQUID use in geophysics. It will start with the early work of the SQUID pioneers including that of Jim Zimmerman and John Clarke and will also cover the development since the early 1990's up to today of a number of magnetometers and gradiometers that have been successfully commercialised and used to create significant impact in the global resources industry. The talk will also cover some of the critical technical challenges that had to be overcome to succeed. It will focus mostly on magnetically unshielded systems used in the field although some laboratory-based systems will be discussed.

  17. Bridging the Educational Research-Teaching Practice Gap: Tools for Evaluating the Quality of Assessment Instruments

    Science.gov (United States)

    Anderson, Trevor R.; Rogan, John M.

    2010-01-01

    Student assessment is central to the educational process and can be used for multiple purposes including, to promote student learning, to grade student performance and to evaluate the educational quality of qualifications. It is, therefore, of utmost importance that assessment instruments are of a high quality. In this article, we present various…

  18. Practical aspects of trapped ion mass spectrometry, 4 theory and instrumentation

    CERN Document Server

    March, Raymond E

    2010-01-01

    The expansion of the use of ion trapping in different areas of mass spectrometry and different areas of application indicates the value of a single source of information drawing together diverse inputs. This book provides an account of the theory and instrumentation of mass spectrometric applications and an introduction to ion trapping devices.

  19. ACCOUNTING PRACTICES FROM FINANCIAL INSTRUMENTS DISCLOSURE PERSPECTIVE – THE CASE OF ROMANIAN BANKING SYSTEM

    Directory of Open Access Journals (Sweden)

    Stefanescu Cristina Alexandrina

    2012-12-01

    Full Text Available International harmonization and convergence of accounting had gradually become one of the most challenging topic of worldwide research and a very hot debated issue in practitioners’ sphere, too. Several studies have addressed both formal and material accounting harmonization along time, a wide range of instruments have been developed and various statistical tools have been used in this respect. Basing on this background, we focused our attention on Romanian banking system which is now experiencing a great challenge by finally entirely adopting IFRS after the first step from 2005 when consolidated financial statements in accordance with IFRS were required and the second one from 2009 when informative individual financial statements under IFRS begun compulsory. Therefore, the objective of our paper is to empirically measure and compare the levels and progress of material accounting harmonization in Romanian banking sector focusing on financial instruments and their related disclosure requirements. First studies conducted in the measurement of harmonization practices (Nair and Frank, 1981; McKinnon and Janell, 1984; Doupnik and Taylor, 1985 started at the beginning of the 80’s, but were merely descriptive, focused on examining how IAS had been adopted in various countries around the world. In the earliest 90’s, there were developed the first instruments for measuring material harmonization, namely the concentration indices (H, C and I Index (Van der Tas, 1988; 1992 and various other forms of these (Archer et al., 1995, which were widely used in various research studies (Herrmann and Thomas, 1995; Aisbitt, 2001; Taplin, 2004. Basing on these measurement tools and cconsidering the main aim of our study – to measure material accounting harmonization in Romanian banking sector – we stated four hypotheses, thus trying to answer our questions: “Are the accounting practices related to financial instruments

  20. High-Tc SQUIDs: Noise and applications

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hsiao-Mei [Univ. of Houston, TX (United States)

    2001-08-01

    A major challenge in the design and operation of high transition temperature (Tc ) Superconducting Quantum Interference Devices (SQUIDs) is their potential to exhibit substantially higher levels of noise at low frequency f when exposed to earth’s magnetic field. To investigate this problem, we studied the noise of high-Tc SQUIDs, directly coupled magnetometers and multilayer magnetometers in both static and changing magnetic fields. The directly coupled magnetometer consists of a dc SQUID connected to a large area pickup loop in parallel. The multilayer magnetometer involves a multiturn flux transformer inductively coupled to a dc SQUID on a separate substrate. All the devices are made of thin films of the high-Tc superconductor YBa2Cu3O7-δ, patterned into 4 μm linewidths. After cooling in a magnetic field, the devices showed no increase in 1/f noise for fields up to threshold values well above the earth’s magnetic field. The devices were also cooled in a magnetic field that was subsequently turned off. The 1/f noise of bare SQUIDs was unchanged for fields up to 12 μT. The addition of the flux transformer containing flux dams increased the sensitivity to magnetic field by a factor of 43 while reducing the threshold field only moderately, to 5 μT. This result implies that the multilayer magnetometer can be rotated in the earth’s magnetic field through an angle of up to 26o without increasing the low frequency noise. The results of these studies were incorporated into a 5-channel high-Tc magnetocardiography system involving two first-derivative SQUID gradiometers and three reference SQUIDs. Each planar gradiometer consists of a directly coupled SQUID magnetometer inductively coupled to the smaller coil of an asymmetric, two-loop flux transformer. The reference SQUIDs are patterned into 4 μm lines. The outputs of the five channels were subtracted in software to form a second-derivative gradiometer. Its

  1. SQUIDs De-fluxing Using a Decaying AC Magnetic Field

    Energy Technology Data Exchange (ETDEWEB)

    Matlashov, Andrei Nikolaevich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Semenov, Vasili Kirilovich [State Univ. of New York (SUNY), Plattsburgh, NY (United States); Anderson, Bill [Senior Scientific, LLC, Albuquerque, NM (United States)

    2016-06-08

    Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

  2. A framework and a measurement instrument for sustainability of work practices in long-term care

    NARCIS (Netherlands)

    S.S. Slaghuis (Sarah); M.M.H. Strating (Mathilde); R.A. Bal (Roland); A.P. Nieboer (Anna)

    2011-01-01

    textabstractBackground: In health care, many organizations are working on quality improvement and/or innovation of their care practices. Although the effectiveness of improvement processes has been studied extensively, little attention has been given to sustainability of the changed work practices

  3. Recommended practices for disinfection and preservation of instrumental for use in laparoscopies

    OpenAIRE

    Machado Guimarães, Solange; Busin, Lurdes; Machado Ludwig, Maria Luiza; Maciel, Miriam; Feix, Maria Augusta; Karnas Hoefel, Heloisa Helena

    2008-01-01

    The present study describes the antimicrobiological methods used for ooscopic instruments and also recommends a routine of material caring, methods and products to be employed. These orientation were also based on the author`s experience with those methods of cleaning, disinfection and sterilization at a school hospital. It is expected to simplify the procedures describing its steps with cientific embasement. El presente estudio espera simplificar las orientaciones seguras sobre los método...

  4. [Pedagogical reflective practice of nursing undergraduates: the portfolio as an instrument].

    Science.gov (United States)

    Vaz, Débora Rodrigues; Prado, Cláudia

    2014-12-01

    Analyzing the narratives related to the pedagogical practice experienced during the Supervised Curricular Internship reported in the portfolios of Nursing undergraduate students, regarding the levels of reflection. This is a documentary descriptive exploratory study that examined two of the activities proposed for the portfolio preparation. Among the 28 analyzed portfolios, all showed the three levels of reflection (technical, critical and metacritical). The students had the opportunity to experience the pedagogical practice and presented reflections at metacritical level, reflecting on their performance, the construction of their teaching identity, and about the importance of reflecting on the practice with the objective of transforming it and transforming themselves.

  5. Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians.

    Science.gov (United States)

    Vayssière, Christophe; Beucher, Gael; Dupuis, Olivier; Feraud, Olivia; Simon-Toulza, Caroline; Sentilhes, Loïc; Meunier, Emmanuelle; Parant, Olivier; Schmitz, Thomas; Riethmuller, Didier; Baud, Olivier; Galley-Raulin, Fabienne; Diemunsch, Pierre; Pierre, Fabrice; Schaal, Jean-Patrick; Fournié, Alain; Oury, Jean François

    2011-11-01

    Routine use of a partograph is associated with a reduction in the use of forceps, but is not associated with a reduction in the use of vacuum extraction (Level A). Early artificial rupture of the membranes, associated with oxytocin perfusion, does not reduce the number of operative vaginal deliveries (Level A), but does increase the rate of fetal heart rate abnormalities (Level B). Early correction of lack of progress in dilatation by oxytocin perfusion can reduce the number of operative vaginal deliveries (Level B). The use of low-concentration epidural infusions of bupivacaine potentiated by morphinomimetics reduces the number of operative interventions compared with larger doses (Level A). Placement of an epidural before 3-cm dilatation does not increase the number of operative vaginal deliveries (Level A). Posterior positions of the fetus result in more operative vaginal deliveries (Level B). Manual rotation of the fetus from a posterior position to an anterior position may reduce the number of operative deliveries (Level C). Walking during labour is not associated with a reduction in the number of operative vaginal deliveries (Level A). Continuous support of the parturient by a midwife or partner/family member during labour reduces the number of operative vaginal deliveries (Level A). Under epidural analgesia, delayed pushing (2h after full dilatation) reduces the number of difficult operative vaginal deliveries (Level A). Ultrasound is recommended if there is any clinical doubt about the presentation of the fetus (Level B). The available scientific data are insufficient to contra-indicate attempted midoperative delivery (professional consensus). The duration of the operative intervention is slightly shorter with forceps than with a vacuum extractor (Level C). Nonetheless, the urgency of operative delivery is not a reason to choose one instrument over another (professional consensus). The cup-shaped vacuum extractor seems to be the instrument of choice for

  6. Curriculum Management Practices in Pedagogical Coordinations of Araucania Schools: Unveiling Technical/Instrumental Rationality, Control and Power Mechanisms Underlying

    Directory of Open Access Journals (Sweden)

    Juan Carlos Beltrán-Véliz

    2016-01-01

    Full Text Available This article consists of a case study regarding curriculum management practices of pedagogical coordinators in schools in Araucania area. The study aims to reveal technical/instrumental rationality, control and power mechanisms that underlie the curriculum management practices of such pedagogical coordinators of schools in Araucania region. A descriptive qualitative design based on the constructionist grounded theory and the constant comparative method is considered. Subjects studied included 12 technical leaders and 22 teachers from Araucania schools. Techniques for collecting information were semi-structured interview and texts for reading. Four categories rose from axial coding. Findings reveal that the teaching process is reduced to an instructional process. Furthermore, there is no uniformity of criteria regarding general functions that must be met. In the same extent, activity coordination is centered on bureaucratic administrative aspects, with main focus on task control. Regulations, programs and educational projects are used as control mechanisms. In addition, absence of spaces for professional discussion of pedagogical work and for constructive criticism is envisioned. This study concludes that pedagogical coordination practices are geared from an “instrumental rationality”, anchored in technical management set up in control and power.

  7. Fabrication and characterization of hybrid Nb-YBCO dc SQUIDs

    International Nuclear Information System (INIS)

    Frack, E.K.; Drake, R.E.; Patt, R.; Radparvar, M.

    1991-01-01

    This paper reports on the fabrication of hybrid low T c /high T c dc SQUIDs of two flavors. The first kind utilizes niobium tunnel junctions and a YBCO film strip as the most inductive portion of the SQUID loop. This configuration allows a direct measurement of the inductance of the YBCO microstrip from which the effective penetration depth can be calculated. The successful fabrication of these SQUIDs has required 1. superconducting Nb-to-YBCO contacts, 2. deposition and patterning of an SiO 2 insulation layer over YBCO, and 3. selective patterning of niobium and SiO 2 relative to YBCO. All these process steps are pertinent to the eventual use of YBCO thin films in electronic devices

  8. Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

    Science.gov (United States)

    Forgione, J.; Benford, D. J.; Buchanan, E. D.; Moseley, S. H.; Rebar, J.; Shafer, R. A.

    2004-01-01

    Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

  9. Working environment interventions – Bridging the gap between policy instruments and practice

    DEFF Research Database (Denmark)

    Hasle, Peter; Limborg, Hans Jørgen; Nielsen, Klaus T.

    2014-01-01

    is paid to why and how public and private organisations subsequently are to improve their working environment. This paper suggests a model which can bridge this gap. It is based on a combination of theories about basic policy instruments (regulation, incentives and information) with realistic analysis...... focusing on mechanisms and context, and finally institutional theory proposing coercive, normative and mimetic mechanisms as explanations for organisational behaviour. The model is applied to an intervention aimed at reduction of the risk of musculoskeletal disorders among bricklayers in Denmark. Our...

  10. Dipole location using SQUID based measurements: Application to magnetocardiography

    Science.gov (United States)

    Mariyappa, N.; Parasakthi, C.; Sengottuvel, S.; Gireesan, K.; Patel, Rajesh; Janawadkar, M. P.; Sundar, C. S.; Radhakrishnan, T. S.

    2012-07-01

    We report a method of inferring the dipole location using iterative nonlinear least square optimization based on Levenberg-Marquardt algorithm, wherein, we use different sets of pseudo-random numbers as initial parameter values. The method has been applied to (i) the simulated data representing the calculated magnetic field distribution produced by a point dipole placed at a known position, (ii) the experimental data from SQUID based measurements of the magnetic field distribution produced by a source coil carrying current, and (iii) the actual experimentally measured magnetocardiograms of human subjects using a SQUID based system.

  11. Application of squids in the Iwate create project

    International Nuclear Information System (INIS)

    Yoshizawa, M.; He, D.F.; Nakai, K.; Kobayashi, K.; Nakamura, Y.; Yaegashi, M.; Ito, M.; Yashiro, H.; Daibo, M.; Simizu, T.; Uchikawa, Y.; Noto, K.

    2005-01-01

    We have developed a 64-channel magnetocardiograph (MCG) system for the diagnosis of heart disease. The MCG is characterized by its display of a unique three-dimensional image of bio-currents flowing inside the human body. The outline of the heart can be displayed without use of MRI. A mobile SQUID-based non-distractive evaluation apparatus was realized by the active shielding technique. The system can offer information from beneath the surface of the specimen by using a saw-wave excitation method. This mobile technology enables us to inspect ferromagnetic materials, whose high magnetic field rules out the use of a conventional SQUID apparatus near them

  12. Scanning high-Tc SQUID imaging system for magnetocardiography

    International Nuclear Information System (INIS)

    Yang, H-C; Wu, T-Y; Horng, H-E; Wu, C-C; Yang, S Y; Liao, S-H; Wu, C-H; Jeng, J T; Chen, J C; Chen, Kuen-Lin; Chen, M J

    2006-01-01

    A scanning magnetocardiography (MCG) system constructed from SQUID sensors offers potential to basic or clinical research in biomagnetism. In this work, we study a first order scanning electronic high-T c (HTS) SQUID MCG system for biomagnetic signals. The scanning MCG system was equipped with an x-y translation bed powered by step motors. Using noise cancellation and μ-metal shielding, we reduced the noise level substantially. The established scanning HTS MCG system was used to study the magnetophysiology of hypercholesterolaemic (HC) rabbits. The MCG data of HC rabbits were analysed. The MCG contour map of HC rabbits provides experimental models for the interpretation of human cardiac patterns

  13. Validation of an instrument to assess toddler feeding practices of Latino mothers.

    Science.gov (United States)

    Chaidez, Virginia; Kaiser, Lucia L

    2011-08-01

    This paper describes qualitative and quantitative aspects of testing a 34-item Toddler-Feeding Questionnaire (TFQ), designed for use in Latino families, and the associations between feeding practices and toddler dietary outcomes. Qualitative methods included review by an expert panel for content validity and cognitive testing of the tool to assess face validity. Quantitative analyses included use of exploratory factor analysis for construct validity; Pearson's correlations for test-retest reliability; Cronbach's alpha (α) for internal reliability; and multivariate regression for investigating relationships between feeding practices and toddler diet and anthropometry. Interviews were conducted using a convenience sample of 94 Latino mother and toddler dyads obtained largely through the Supplemental Nutrition Program for Women, Infants and Children (WIC). Data collection included household characteristics, self-reported early-infant feeding practices, the toddler's dietary intake, and anthropometric measurements. Factor analysis suggests the TFQ contains three subscales: indulgent; authoritative; and environmental influences. The TFQ demonstrated acceptable reliability for most measures. As hypothesized, indulgent practices in Latino toddlers were associated with increased energy consumption and higher intakes of total fat, saturated fat, and sweetened beverages. This tool may be useful in future research exploring the relationship of toddler feeding practices to nutritional outcomes in Latino families. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Content validity--establishing and reporting the evidence in newly developed patient-reported outcomes (PRO) instruments for medical product evaluation: ISPOR PRO good research practices task force report: part 1--eliciting concepts for a new PRO instrument.

    Science.gov (United States)

    Patrick, Donald L; Burke, Laurie B; Gwaltney, Chad J; Leidy, Nancy Kline; Martin, Mona L; Molsen, Elizabeth; Ring, Lena

    2011-12-01

    The importance of content validity in developing patient reported outcomes (PRO) instruments is stressed by both the US Food and Drug Administration and the European Medicines Agency. Content validity is the extent to which an instrument measures the important aspects of concepts that developers or users purport it to assess. A PRO instrument measures the concepts most significant and relevant to a patient's condition and its treatment. For PRO instruments, items and domains as reflected in the scores of an instrument should be important to the target population and comprehensive with respect to patient concerns. Documentation of target population input in item generation, as well as evaluation of patient understanding through cognitive interviewing, can provide the evidence for content validity. Developing content for, and assessing respondent understanding of, newly developed PRO instruments for medical product evaluation will be discussed in this two-part ISPOR PRO Good Research Practices Task Force Report. Topics include the methods for generating items, documenting item development, coding of qualitative data from item generation, cognitive interviewing, and tracking item development through the various stages of research and preparing this tracking for submission to regulatory agencies. Part 1 covers elicitation of key concepts using qualitative focus groups and/or interviews to inform content and structure of a new PRO instrument. Part 2 covers the instrument development process, the assessment of patient understanding of the draft instrument using cognitive interviews and steps for instrument revision. The two parts are meant to be read together. They are intended to offer suggestions for good practices in planning, executing, and documenting qualitative studies that are used to support the content validity of PRO instruments to be used in medical product evaluation. Copyright © 2011 International Society for Pharmacoeconomics and Outcomes Research (ISPOR

  15. Examining Ratings on the VAL-ED Evaluation Instrument of Principals to Improve Instructional Leadership Practices

    Science.gov (United States)

    Babin, Erin Pevey

    2017-01-01

    The biggest challenge facing American public schools today is increasing student achievement, and this depends on the educational system's ability to improve the quality of instruction. Principals play a key role in improving the quality of instruction on their campus through the instructional leadership practices they engage in on a daily basis.…

  16. Employing the Five-Factor Mentoring Instrument: Analysing Mentoring Practices for Teaching Primary Science

    Science.gov (United States)

    Hudson, Peter; Usak, Muhammet; Savran-Gencer, Ayse

    2009-01-01

    Primary science education is a concern around the world and quality mentoring within schools can develop pre-service teachers' practices. A five-factor model for mentoring has been identified, namely, personal attributes, system requirements, pedagogical knowledge, modelling, and feedback. Final-year pre-service teachers (mentees, n = 211) from…

  17. Where Critical Postmodern Theory Meets Practice: Working in the Intersection of Instrumental, Social, and Cultural Education.

    Science.gov (United States)

    Grace, Andre P.

    1997-01-01

    Outlines a critical postmodern adult education practice that is inclusive of peoples and knowledges and inhabits a dynamic space. Key concepts include identity difference; intersection of power relations; community as a social contract; and conflict, voice, and dialog for transformative learning. (SK)

  18. Mastery, Enjoyment, Tradition and Innovation: A Reflective Practice Model for Instrumental and Vocal Teachers

    Science.gov (United States)

    Parkinson, Tom

    2016-01-01

    This article offers a model to assist music teachers in reflecting on their teaching practice in relation to their aims and values. Initially developed as a workshop aid for use on a music education MA program, the model is intended to provoke critical engagement with two prominent tensions in music education: that between mastery and enjoyment,…

  19. Issues of academic study and practical acquisition of Tuvan music (a case study of Tuvan instrumental music

    Directory of Open Access Journals (Sweden)

    Valentina Yu. Suzukey

    2017-06-01

    Full Text Available In the 20th century, Tuvan music culture has undergone dramatic upheaval and a number of transformations. Today we face an acute need to rethink the achievements and losses incurred over that period of time. The objective of this article is to reconsider some basic parameters of Tuvan music culture that are responsible for preserving the integrity of its sound structure. The relevance of the topic is due to a current conceptual rift between the musical practices and their scholarly interpretations. In the Soviet period, culture throughout the entire USSR was solely driven by the European model of musical development with no reliance on practices typical for ethnical cultures. We are currently witnessing a decline in the numbers of those representing oral and audial traditional culture, while the numbers of music college graduates, those who studied at conservatoires, universities, academies of culture and arts, and thus come as bearers of values lying outside of the tradition. Tuvan musical practice is experiencing an invasion of academic vocabulary and non-relevant appraisal criteria. However, Tuvan musical culture, having always been primarily oral, has developed its own acoustic structure, as well as mechanisms and methods for non-scriptory transfer of knowledge. But these vernacular methods are still insufficiently explored. The author postulates that the system of Tuvan instrumental music organization is unique and acts as a basis for unconventional sound of musical instruments and xöömei (throat singing. Distinctive timbre and inimitable flair of the sound is achieved by original system of bourdon-overtone sound coordination. Music is created for audial enjoyment. But musicologists (mainly in Russia are still analyzing the notation they keep making of performed folk instrumental pieces and xöömei. Such an approach drastically narrows the entire panorama of traditional instrumental music. A positive factor is that contemporary Tuvan

  20. Transmutation of singularities and zeros in graded index optical instruments: a methodology for designing practical devices.

    Science.gov (United States)

    Hooper, I R; Philbin, T G

    2013-12-30

    We describe a design methodology for modifying the refractive index profile of graded-index optical instruments that incorporate singularities or zeros in their refractive index. The process maintains the device performance whilst resulting in graded profiles that are all-dielectric, do not require materials with unrealistic values, and that are impedance matched to the bounding medium. This is achieved by transmuting the singularities (or zeros) using the formalism of transformation optics, but with an additional boundary condition requiring the gradient of the co-ordinate transformation be continuous. This additional boundary condition ensures that the device is impedance matched to the bounding medium when the spatially varying permittivity and permeability profiles are scaled to realizable values. We demonstrate the method in some detail for an Eaton lens, before describing the profiles for an "invisible disc" and "multipole" lenses.

  1. A perspectiva pragmática nas pesquisas sobre prática instrumental: condições e implicações procedimentais A pragmatic perspective in instrumental practice research: conditions and procedural implications

    Directory of Open Access Journals (Sweden)

    Regina Antunes Teixeira dos Santos

    2009-01-01

    Full Text Available Pesquisas em prática instrumental evidenciam tendências que expressam certos aspectos de racionalidade calculada da ação e apontam para uma perspectiva pragmática de engajamento pessoal frente às situações de prática. Sistematizações sobre modos intencionais de proceder na prática instrumental em conexão com níveis de especialização músico-instrumental encontram-se não somente nos resultados dessas pesquisas, mas também implícitos nos conceitos de prática. Assim, o presente artigo discute a natureza e a finalidade das condições procedimentais implícitas nos conceitos e resultados de pesquisas em prática instrumental. Implicações procedimentais apresentam-se também nas discussões referentes à quantidade e a qualidade na prática, e justificam a existência de níveis diferenciados de especialização músico-instrumental na prática. O presente artigo aborda ainda a relação entre procedimentos e estratégias de prática.Research in instrumental practice has shown some trends that express certain aspects of calculated rationality, and point out to a pragmatic regime of personal commitment during practice. The systematization of the intentional procedures of the performer in order to improve and to refine one's music expertise level is present in research as well as in the concepts of instrumental practice. Thus, the present article discusses the nature and the goals of the procedimental conditions implicit in the concepts and research results in instrumental practice. Procedimental implications are also present in the discussion of the role of quantity and quality in the practice and justify the existence of different levels of instrumental expertise in the practice. This article also raises the relationship between procedures and strategies of practice.

  2. Can understanding squid life-history strategies and recruitment ...

    African Journals Online (AJOL)

    Current views of the links between life-history strategies and recruitment processes in fish are contrasted with the pattern emerging for squid. A general perspective is that the roles of space and time are reversed in the two groups, suggesting that management strategies also should differ. The space/time reversal appears to ...

  3. Scanning SQUID susceptometers with sub-micron spatial resolution

    International Nuclear Information System (INIS)

    Kirtley, John R.; Rosenberg, Aaron J.; Palmstrom, Johanna C.; Holland, Connor M.; Moler, Kathryn A.; Paulius, Lisa; Spanton, Eric M.; Schiessl, Daniel; Jermain, Colin L.; Gibbons, Jonathan; Fung, Y.-K.K.; Gibson, Gerald W.; Huber, Martin E.; Ralph, Daniel C.; Ketchen, Mark B.

    2016-01-01

    Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ_0/Hz"1"/"2. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

  4. The magnapinnidae, a newly discovered family of oceanic Squid ...

    African Journals Online (AJOL)

    A peculiar squid paralarva from Hawaiian waters was described by Young (1991, Bull. mar. Sci. 49(1–2): 162–185), but it could not be assigned to any known family. Two larger juvenile specimens have now been obtained, one collected near the surface in the eastern Pacific Ocean and the other rehydrated from a dried ...

  5. A mass stranding of the squid martialia hyadesi Rochebrune and ...

    African Journals Online (AJOL)

    1997-02-11

    Feb 11, 1997 ... All animals were immature, with females in lower stages of maturity than males. No predatory marine mammals were seen in the area during or after the stranding event. An interpretation of the stranding is presented with reference to historical reports of squid strandings worldwide. Evidence suggests some ...

  6. Scanning SQUID susceptometers with sub-micron spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kirtley, John R., E-mail: jkirtley@stanford.edu; Rosenberg, Aaron J.; Palmstrom, Johanna C.; Holland, Connor M.; Moler, Kathryn A. [Department of Applied Physics, Stanford University, Stanford, California 94305-4045 (United States); Paulius, Lisa [Department of Physics, Western Michigan University, Kalamazoo, Michigan 49008-5252 (United States); Spanton, Eric M. [Department of Physics, Stanford University, Stanford, California 94305-4045 (United States); Schiessl, Daniel [Attocube Systems AG, Königinstraße 11A, 80539 Munich (Germany); Jermain, Colin L.; Gibbons, Jonathan [Department of Physics, Cornell University, Cornell, Ithaca, New York 14853 (United States); Fung, Y.-K.K.; Gibson, Gerald W. [IBM Research Division, T. J. Watson Research Center, Yorktown Heights, New York 10598 (United States); Huber, Martin E. [Department of Physics, University of Colorado Denver, Denver, Colorado 80217-3364 (United States); Ralph, Daniel C. [Department of Physics, Cornell University, Cornell, Ithaca, New York 14853 (United States); Kavli Institute at Cornell, Ithaca, New York 14853 (United States); Ketchen, Mark B. [OcteVue, Hadley, Massachusetts 01035 (United States)

    2016-09-15

    Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

  7. A contribution to the biology of the ommastrephid squid Martialia ...

    African Journals Online (AJOL)

    Updated knowledge on the distribution and biology of the ommastrephid squid Martialia hyadesi in the South-West Atlantic Ocean is presented. Although the species has an Antarctic circumpolar distribution, its most frequent area of appearance is in the South-West Atlantic, where commercial catches have been made.

  8. A method of background noise cancellation for SQUID applications

    International Nuclear Information System (INIS)

    He, D F; Yoshizawa, M

    2003-01-01

    When superconducting quantum inference devices (SQUIDs) operate in low-cost shielding or unshielded environments, the environmental background noise should be reduced to increase the signal-to-noise ratio. In this paper we present a background noise cancellation method based on a spectral subtraction algorithm. We first measure the background noise and estimate the noise spectrum using fast Fourier transform (FFT), then we subtract the spectrum of background noise from that of the observed noisy signal and the signal can be reconstructed by inverse FFT of the subtracted spectrum. With this method, the background noise, especially stationary inferences, can be suppressed well and the signal-to-noise ratio can be increased. Using high-T C radio-frequency SQUID gradiometer and magnetometer, we have measured the magnetic field produced by a watch, which was placed 35 cm under a SQUID. After noise cancellation, the signal-to-noise ratio could be greatly increased. We also used this method to eliminate the vibration noise of a cryocooler SQUID

  9. Flicker (1/f) noise in tunnel junction DC SQUIDS

    International Nuclear Information System (INIS)

    Koch, R.H.; Clarke, J.; Goubau, W.M.; Martinis, J.M.; Pegrum, C.M.; Van Harlingen, D.J.

    1983-01-01

    We have measured the spectral density of the 1/f voltage noise in current-biased resistively shunted Josephson tunnel junctions and dc SQUIDs. A theory in which fluctuations in the temperature give rise to fluctuations in the critical current and hence in the voltage predicts the magnitude of the noise quite accurately for junctions with areas of about 2 x 10 4 μm 2 , but significantly overestimates the noise for junctions with areas of about 6 μm 2 . DC SQUIDs fabricated from these two types of junctions exhibit substantially more 1/f voltage noise than would be predicted from a model in which the noise arises from critical current fluctuations in the junctions. This result was confirmed by an experiment involving two different bias current and flux modulation schemes, which demonstrated that the predominant 1/f voltage noise arises not from critical current fluctuations, but from some unknown source that can be regarded as an apparent 1/f flux noise. Measurements on five different configurations of dc SQUIDs fabricated with thin-film tunnel junctions and with widely varying areas, inductances, and junction capacitances show that the spectral density of the 1/f equivalent flux noise is roughtly constant, within a factor of three of (10 -10 /f)phi 2 0 Hz -1 . It is emphasized that 1/f flux noise may not be the predominant source of 1/f noise in SQUIDS fabricated with other technologies

  10. SQUID developments for the gravitational wave antenna MiniGRAIL

    NARCIS (Netherlands)

    Pleikies, J.; Usenko, O.; Kuit, K.H.; Flokstra, Jakob; de Waard, A.; de Waard, A.; Frossati, G.

    2007-01-01

    We designed two different sensor SQUIDs for the readout of the resonant mass gravitational wave detector MiniGRAIL. Both designs have integrated input inductors in the order of 1.5 muH and are planned for operation in the mK temperature range. Cooling fins were added to the shunt resistors. The

  11. The biomass and ecology of chokka squid Loligo vulgaris reynaudii ...

    African Journals Online (AJOL)

    Migration, stock size and ecology of chokka squid Loligo vulgaris reynaudii off the West Coast of South Africa were studied and their relationship to other regions compared by analysis of distributional, biomass, and size composition, and biological data collected from biannual research cruises from 1983-1987. Biomass ...

  12. spawning grounds for chokka squid Loligo vulgaris reynaudii, using

    African Journals Online (AJOL)

    denise

    Swimming movements in relation to egg beds have been studied using acoustic micro-electronic transmitters implanted in squid and tracked via 3-D radio-linked acoustic positioning telemetry (O'Dor et al. 1996, 1998, Sauer et al. 1997). Most of these methods are either impractical or would be severely limited on the deeper ...

  13. A practical tablet-based hearing aid configuration as an exemplar project for students of instrumentation

    Directory of Open Access Journals (Sweden)

    Ricardo Simeoni

    2015-06-01

    Full Text Available This paper presents the configuration and digital signal processing details of a tablet-based hearing aid transmitting wirelessly to standard earphones, whereby the tablet performs full sound processing rather than solely providing a means of setting adjustment by streaming to conventional digital hearing aids. The presented device confirms the recognized advantages of this tablet-based approach (e.g., in relation to cost, frequency domain processing, amplification range, versatility of functionality, component battery rechargeability, and flags the future wider-spread availability of such hearing solutions within mainstream healthcare. The use of a relatively high sampling frequency was found to be beneficial for device performance, while the use of optional off-the-shelf add-on components (e.g., data acquisition device, high fidelity microphone, compact wireless transmitter/ receiver, wired headphones are also discussed in relation to performance optimization. The easy-to-follow configuration utilized is well suited to student learning/research instrumentation projects within the health and biomedical sciences. In this latter regard, the presented device was pedagogically integrated into a flipped classroom approach for the teaching of bioinstrumentation within an Allied Health Sciences School, with the subsequent establishment of positive student engagement outcomes.

  14. A Practical Tablet-Based Hearing Aid Configuration as an Exemplar Project for Students of Instrumentation.

    Science.gov (United States)

    Simeoni, Ricardo

    2015-06-11

    This paper presents the configuration and digital signal processing details of a tablet-based hearing aid transmitting wirelessly to standard earphones, whereby the tablet performs full sound processing rather than solely providing a means of setting adjustment by streaming to conventional digital hearing aids. The presented device confirms the recognized advantages of this tablet-based approach (e.g., in relation to cost, frequency domain processing, amplification range, versatility of functionality, component battery rechargeability), and flags the future wider-spread availability of such hearing solutions within mainstream healthcare. The use of a relatively high sampling frequency was found to be beneficial for device performance, while the use of optional off-the-shelf add-on components (e.g., data acquisition device, high fidelity microphone, compact wireless transmitter/receiver, wired headphones) are also discussed in relation to performance optimization. The easy-to-follow configuration utilized is well suited to student learning/research instrumentation projects within the health and biomedical sciences. In this latter regard, the presented device was pedagogically integrated into a flipped classroom approach for the teaching of bioinstrumentation within an Allied Health Sciences School, with the subsequent establishment of positive student engagement outcomes.

  15. Measurement invariance of an instrument assessing sustainability of school-based universal behavior practices.

    Science.gov (United States)

    Mercer, Sterett H; McIntosh, Kent; Strickland-Cohen, M Kathleen; Horner, Robert H

    2014-06-01

    The purpose of the study was to examine the extent to which the School-Wide Universal Behavior Sustainability Index: School Teams (SUBSIST; McIntosh, Doolittle, Vincent, Horner, & Ervin, 2009), a measure of school and district contextual factors that promote the sustainability of school practices, demonstrated measurement invariance across groups of schools that differed in length of time implementing school-wide Positive Behavioral Interventions and Supports (PBIS; Sugai & Horner, 2009), student ethnic composition, and student socioeconomic status (SES). School PBIS team members and district coaches representing 860 schools in 14 U.S. states completed the SUBSIST. Findings supported strong measurement invariance, for all items except 1, of a model with two school-level factors (School Priority and Team Use of Data) and 2 district-level factors (District Priority and Capacity Building) across groups of schools at initial implementation, institutionalization, and sustainability phases of PBIS implementation. Schools in the sustainability phase were rated significantly higher on School Priority and Team Use of Data than schools in initial implementation. Strong measurement invariance held across groups of schools that differed in student ethnicity and SES. The findings regarding measurement invariance are important for future longitudinal investigations of factors that may promote the sustained implementation of school practices. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  16. Validation of an instrument to assess evidence-based practice knowledge, attitudes, access, and confidence in the dental environment.

    Science.gov (United States)

    Hendricson, William D; Rugh, John D; Hatch, John P; Stark, Debra L; Deahl, Thomas; Wallmann, Elizabeth R

    2011-02-01

    This article reports the validation of an assessment instrument designed to measure the outcomes of training in evidence-based practice (EBP) in the context of dentistry. Four EBP dimensions are measured by this instrument: 1) understanding of EBP concepts, 2) attitudes about EBP, 3) evidence-accessing methods, and 4) confidence in critical appraisal. The instrument-the Knowledge, Attitudes, Access, and Confidence Evaluation (KACE)-has four scales, with a total of thirty-five items: EBP knowledge (ten items), EBP attitudes (ten), accessing evidence (nine), and confidence (six). Four elements of validity were assessed: consistency of items within the KACE scales (extent to which items within a scale measure the same dimension), discrimination (capacity to detect differences between individuals with different training or experience), responsiveness (capacity to detect the effects of education on trainees), and test-retest reliability. Internal consistency of scales was assessed by analyzing responses of second-year dental students, dental residents, and dental faculty members using Cronbach coefficient alpha, a statistical measure of reliability. Discriminative validity was assessed by comparing KACE scores for the three groups. Responsiveness was assessed by comparing pre- and post-training responses for dental students and residents. To measure test-retest reliability, the full KACE was completed twice by a class of freshman dental students seventeen days apart, and the knowledge scale was completed twice by sixteen faculty members fourteen days apart. Item-to-scale consistency ranged from 0.21 to 0.78 for knowledge, 0.57 to 0.83 for attitude, 0.70 to 0.84 for accessing evidence, and 0.87 to 0.94 for confidence. For discrimination, ANOVA and post hoc testing by the Tukey-Kramer method revealed significant score differences among students, residents, and faculty members consistent with education and experience levels. For responsiveness to training, dental students

  17. Development of an item bank for food parenting practices based on published instruments and reports from Canadian and US parents.

    Science.gov (United States)

    O'Connor, Teresia M; Pham, Truc; Watts, Allison W; Tu, Andrew W; Hughes, Sheryl O; Beauchamp, Mark R; Baranowski, Tom; Mâsse, Louise C

    2016-08-01

    Research to understand how parents influence their children's dietary intake and eating behaviors has expanded in the past decades and a growing number of instruments are available to assess food parenting practices. Unfortunately, there is no consensus on how constructs should be defined or operationalized, making comparison of results across studies difficult. The aim of this study was to develop a food parenting practice item bank with items from published scales and supplement with parenting practices that parents report using. Items from published scales were identified from two published systematic reviews along with an additional systematic review conducted for this study. Parents (n = 135) with children 5-12 years old from the US and Canada, stratified to represent the demographic distribution of each country, were recruited to participate in an online semi-qualitative survey on food parenting. Published items and parent responses were coded using the same framework to reduce the number of items into representative concepts using a binning and winnowing process. The literature contributed 1392 items and parents contributed 1985 items, which were reduced to 262 different food parenting concepts (26% exclusive from literature, 12% exclusive from parents, and 62% represented in both). Food parenting practices related to 'Structure of Food Environment' and 'Behavioral and Educational' were emphasized more by parent responses, while practices related to 'Consistency of Feeding Environment' and 'Emotional Regulation' were more represented among published items. The resulting food parenting item bank should next be calibrated with item response modeling for scientists to use in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.

    Science.gov (United States)

    Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul

    2014-06-01

    While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

  19. Use of existing patient-reported outcome (PRO) instruments and their modification: the ISPOR Good Research Practices for Evaluating and Documenting Content Validity for the Use of Existing Instruments and Their Modification PRO Task Force Report.

    Science.gov (United States)

    Rothman, Margaret; Burke, Laurie; Erickson, Pennifer; Leidy, Nancy Kline; Patrick, Donald L; Petrie, Charles D

    2009-01-01

    Patient-reported outcome (PRO) instruments are used to evaluate the effect of medical products on how patients feel or function. This article presents the results of an ISPOR task force convened to address good clinical research practices for the use of existing or modified PRO instruments to support medical product labeling claims. The focus of the article is on content validity, with specific reference to existing or modified PRO instruments, because of the importance of content validity in selecting or modifying an existing PRO instrument and the lack of consensus in the research community regarding best practices for establishing and documenting this measurement property. Topics addressed in the article include: definition and general description of content validity; PRO concept identification as the important first step in establishing content validity; instrument identification and the initial review process; key issues in qualitative methodology; and potential threats to content validity, with three case examples used to illustrate types of threats and how they might be resolved. A table of steps used to identify and evaluate an existing PRO instrument is provided, and figures are used to illustrate the meaning of content validity in relationship to instrument development and evaluation. RESULTS & RECOMMENDATIONS: Four important threats to content validity are identified: unclear conceptual match between the PRO instrument and the intended claim, lack of direct patient input into PRO item content from the target population in which the claim is desired, no evidence that the most relevant and important item content is contained in the instrument, and lack of documentation to support modifications to the PRO instrument. In some cases, careful review of the threats to content validity in a specific application may be reduced through additional well documented qualitative studies that specifically address the issue of concern. Published evidence of the content

  20. Characterisation of micro and nano SQUIDs at variable temperature and magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Koehn, Claudia; Storm, Jan-Hendrik; Bechstein, Sylke; Schurig, Thomas [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)

    2015-07-01

    SQUIDs are highly suited to investigate the magnetic properties of samples with small dimensions, such as nanoparticles, or to read out nanoelectromechanical systems (NEMS). Due to the small sample size, SQUIDs with dimensions in the μm or nm regime are desirable. These micro or nano SQUIDs should have a low noise and no hysteresis in the current-voltage-characteristic, even when operated in high magnetic fields of up to several 100 mT. To investigate such SQUID, we developed measurement setups which can simulate the measurement conditions of the intended SQUID application. The design and performance of two measurement setups will be shown and compared. One setup uses a dipstick that is immersed in liquid helium and can be evacuated to provide SQUID temperatures between 4.5 K and 10 K. The other one uses an evaporation cryostat so that the temperature can be varied from 2 K to 60 K. Both setups are equipped with coils to enable SQUID operation in variable magnetic field. To minimize noise, the output of the SQUID under test is preamplified by a SQUID series array which is operated at 4.2 K. First results of the characterisation of micro and nano SQUIDs will be presented.

  1. The IHE-Bus: a practical tool to instrument and simulate IHE deployment

    Science.gov (United States)

    Shani, Uri; Carmeli, Boaz; Kol, Tomer; Ram, Roni; Shabo, Amnon

    2005-04-01

    The IHE (Integrating the Healthcare Enterprise) initiative provides essential guidelines for the deployment of a digital health information management environment. IHE, while not inventing new standards, creates a system-level and component-level design, based on the products of the leading standards, HL7, DICOM, and more. As such, IHE can be viewed as the "Standard of Standards". The most significant value of IHE is that vendors can work on specific components of the enterprise solution, playing one or more of the IHE actor roles. IHE defines, for each actor, its external interface to the other actors in the system. Yet, the integrator of an entire IHE solution may find this job extremely difficult. The larger the number of vendors involved in the solution, the tougher the job. The complexity of coordinating all the components to work as one coherent solution multiplies and may become intractable. IHE defines very well "what" should be done, but not "how." IHE-Bus offers a practical solution for the "how" question, with many advantages. This solution is borrowed from the business integration sphere. IHE becomes a platform, and each actor can be "plugged" into it in a simple step. New actors are independent of other actors already in the system. Missing actors can be simulated (by a "stub") until replaced with the real product in the future. Moreover, the entire IHE network is managed as a single coherent system with powerful tools encapsulating the enormous amount of knowledge and expertise deemed necessary to uphold this job.

  2. Magnetic shield effect simulation of superconducting film shield covering directly coupled HTS dc-SQUID magnetometer

    International Nuclear Information System (INIS)

    Terauchi, N.; Noguchi, S.; Igarashi, H.

    2011-01-01

    A superconducting film shield over a SQUID ring improves the robustness of the SQUID with respect to magnetic noise. Supercurrent in the SQUID magnetometer and the superconducting film shield were simulated. The superconducting film shield reduces the influence of the external magnetic field on the SQUID ring. An HTS SQUID is a high sensitive magnetic sensor. In recent years, the HTS SQUID is widely used in various applications. In some applications, high robustness with respect to magnetic noise is required to realize stable operation at outside of a magnetic shielding room. The target of this paper is a directly coupled HTS dc-SQUID magnetometer. To enhance the robustness of the SQUID magnetometer, use of a superconducting thin film shield has been proposed. The magnetic field directly penetrating the SQUID ring causes the change of the critical current of Josephson junction, and then the SQUID magnetometer transitions into inoperative state. In order to confirm the magnetic shield effect of the superconducting film shield, electromagnetic field simulation with 3D edge finite element method was performed. To simulate the high temperature superconductor, E-J characteristics and c-axis anisotropy are considered. To evaluate the effect of the superconducting film shield, an external magnetic field which is supposed to be a magnetic noise is applied. From the simulation results, the time transition of the magnetic flux penetrating the SQUID ring is investigated and the effect of the superconducting film shield is confirmed. The amplitude of the magnetic flux penetrating the SQUID ring can be reduced to about one-sixth since the superconducting film shield prevents the magnetic noise from directly penetrating the SQUID ring.

  3. Developing a theory-based instrument to assess the impact of continuing professional development activities on clinical practice: a study protocol

    Directory of Open Access Journals (Sweden)

    Rousseau Michel

    2011-03-01

    Full Text Available Abstract Background Continuing professional development (CPD is one of the principal means by which health professionals (i.e. primary care physicians and specialists maintain, improve, and broaden the knowledge and skills required for optimal patient care and safety. However, the lack of a widely accepted instrument to assess the impact of CPD activities on clinical practice thwarts researchers' comparisons of the effectiveness of CPD activities. Using an integrated model for the study of healthcare professionals' behaviour, our objective is to develop a theory-based, valid, reliable global instrument to assess the impact of accredited CPD activities on clinical practice. Methods Phase 1: We will analyze the instruments identified in a systematic review of factors influencing health professionals' behaviours using criteria that reflect the literature on measurement development and CPD decision makers' priorities. The outcome of this phase will be an inventory of instruments based on social cognitive theories. Phase 2: Working from this inventory, the most relevant instruments and their related items for assessing the concepts listed in the integrated model will be selected. Through an e-Delphi process, we will verify whether these instruments are acceptable, what aspects need revision, and whether important items are missing and should be added. The outcome of this phase will be a new global instrument integrating the most relevant tools to fit our integrated model of healthcare professionals' behaviour. Phase 3: Two data collections are planned: (1 a test-retest of the new instrument, including item analysis, to assess its reliability and (2 a study using the instrument before and after CPD activities with a randomly selected control group to explore the instrument's mere-measurement effect. Phase 4: We will conduct individual interviews and focus groups with key stakeholders to identify anticipated barriers and enablers for implementing the

  4. A critical appraisal of chronic kidney disease mineral and bone disorders clinical practice guidelines using the AGREE II instrument.

    Science.gov (United States)

    Sekercioglu, Nigar; Al-Khalifah, Reem; Ewusie, Joycelyne Efua; Elias, Rosilene M; Thabane, Lehana; Busse, Jason W; Akhtar-Danesh, Noori; Iorio, Alfonso; Isayama, Tetsuya; Martínez, Juan Pablo Díaz; Florez, Ivan D; Guyatt, Gordon H

    2017-02-01

    Patients with chronic kidney disease mineral and bone disorders (CKD-MBD) suffer high rates of morbidity and mortality, in particular related to bone and cardiovascular outcomes. The management of CKD-MBD remains challenging. The objective of this systematic survey is to critically appraise clinical practice guidelines (CPGs) addressing CKD-MBD. Data sources included MEDLINE, EMBASE, the National Guideline Clearinghouse, Guideline International Network and Turning Research into Practice up to May 2016. Teams of two reviewers, independently and in duplicate, screened titles and abstracts and potentially eligible full text reports to determine eligibility and subsequently appraised the guidelines using the Advancing Guideline Development, Reporting and Evaluation in Health Care instrument II (AGREE). Sixteen CPGs published from 2003 to 2015 addressing the diagnosis and management of CKD-MBD in adult patients (11 English, two Spanish, one Italian, one Portuguese and one Slovak) proved eligible. The National Institute for Health and Care Excellence guideline performed best with respect to AGREE II criteria; only three other CPGs warranted high scores on all domains. All other guidelines received scores of under 60% on one or more domains. Major discrepancies in recommendations were not, however, present, and we found no association between quality of CPGs which was not associated with resulting recommendations. Most guidelines assessing CKD-MBD suffer from serious shortcomings using AGREE criteria although limitations with respect to AGREE criteria do not necessarily lead to inappropriate recommendations.

  5. Robot-arm-based mobile HTS SQUID system for NDE of structures

    Energy Technology Data Exchange (ETDEWEB)

    Yotsugi, K; Hatsukade, Y; Tanaka, S [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tenpaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp

    2008-02-01

    A robot-arm-based mobile HTS SQUID system was developed for NDE of fixed targets. To realize the system, active magnetic shielding technique using fluxgate as reference sensor for ambient field was applied to a cryocooler-based HTS SQUID gradiometer that was mounted on commercial robot-arm. In this technique, ambient field noise and pulse noise of 550 nT from robot were measured by the fluxgate near the SQUID, and then the fluxgate output was negatively fed back to generate compensation field around the SQUID and fluxgate. The noise from robot was reduced by a factor of about 20 and the shielding technique enabled the HTS SQUID to move in unshielded environment by the robot-arm without flux-trapping or unlocking at 10 mm/s. System noise measurement and inspection of hidden cracks in multi-layer composite-metal structure were demonstrated using the mobile SQUID-NDE system.

  6. Two-stage SQUID systems and transducers development for MiniGRAIL

    International Nuclear Information System (INIS)

    Gottardi, L; Podt, M; Bassan, M; Flokstra, J; Karbalai-Sadegh, A; Minenkov, Y; Reinke, W; Shumack, A; Srinivas, S; Waard, A de; Frossati, G

    2004-01-01

    We present measurements on a two-stage SQUID system based on a dc-SQUID as a sensor and a DROS as an amplifier. We measured the intrinsic noise of the dc-SQUID at 4.2 K. A new dc-SQUID has been fabricated. It was specially designed to be used with MiniGRAIL transducers. Cooling fins have been added in order to improve the cooling of the SQUID and the design is optimized to achieve the quantum limit of the sensor SQUID at temperatures above 100 mK. In this paper we also report the effect of the deposition of a Nb film on the quality factor of a small mass Al5056 resonator. Finally, the results of Q-factor measurements on a capacitive transducer for the current MiniGRAIL run are presented

  7. A SQUID gradiometer module with wire-wound pickup antenna and integrated voltage feedback circuit

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Guofeng [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences (CAS), Shanghai 200050 (China); Peter Gruenberg Institute (PGI-8), Forschungszentrum Juelich (FZJ), D-52425 Juelich (Germany); Joint Research Laboratory on Superconductivity and Bioelectronics, Collaboration between CAS-Shanghai and FZJ, Shanghai 200050 (China); Graduate University of the Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Yi, E-mail: y.zhang@fz-juelich.de [Peter Gruenberg Institute (PGI-8), Forschungszentrum Juelich (FZJ), D-52425 Juelich (Germany); Joint Research Laboratory on Superconductivity and Bioelectronics, Collaboration between CAS-Shanghai and FZJ, Shanghai 200050 (China); Zhang Shulin [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences (CAS), Shanghai 200050 (China); Joint Research Laboratory on Superconductivity and Bioelectronics, Collaboration between CAS-Shanghai and FZJ, Shanghai 200050 (China); Krause, Hans-Joachim [Peter Gruenberg Institute (PGI-8), Forschungszentrum Juelich (FZJ), D-52425 Juelich (Germany); Joint Research Laboratory on Superconductivity and Bioelectronics, Collaboration between CAS-Shanghai and FZJ, Shanghai 200050 (China); and others

    2012-10-15

    The performance of the direct readout schemes for dc SQUID, Additional Positive Feedback (APF), noise cancellation (NC) and SQUID bootstrap circuit (SBC), have been studied in conjunction with planar SQUID magnetometers. In this paper, we examine the NC technique applied to a niobium SQUID gradiometer module with an Nb wire-wound antenna connecting to a dual-loop SQUID chip with an integrated voltage feedback circuit for suppression of the preamplifier noise contribution. The sensitivity of the SQUID gradiometer module is measured to be about 1 fT/(cm {radical}Hz) in the white noise range in a magnetically shielded room. Using such gradiometer, both MCG and MEG signals are recorded.

  8. A three-axis SQUID-based absolute vector magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Schönau, T.; Schmelz, M.; Stolz, R.; Anders, S.; Linzen, S.; Meyer, H.-G. [Department of Quantum Detection, Leibniz Institute of Photonic Technology, Jena 07745 (Germany); Zakosarenko, V.; Meyer, M. [Supracon AG, An der Lehmgrube 11, Jena 07751 (Germany)

    2015-10-15

    We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

  9. The squid-Vibrio symbioses: from demes to genes.

    Science.gov (United States)

    Kimbell, Jennifer R; McFall-Ngai, Margaret J

    2003-04-01

    The monospecific light organ association between the Hawaiian sepiolid squid Euprymna scolopes and the marine luminous bacterium Vibrio fischeri has been used as a model for the study of the most common type of coevolved animal-bacterial interaction; i.e., the association of Gram-negative bacteria with the extracellular apical surfaces of polarized epithelia. Analysis of the squid-vibrio symbiosis has ranged from characterizations of the harvesting mechanisms by which the host ensures colonization by the appropriate symbiont to identification of bacteria-induced changes in host gene expression that accompany the establishment and maintenance of the relationship. Studies of this model have been enhanced by extensive collaboration with microbiologists, who are able to manipulate the genetics of the bacterial symbiont. The results of our studies have indicated that initiation and persistence of the association requires a complex, reciprocal molecular dialogue between these two phylogenetically distant partners.

  10. On-site detection of packaged squid freshness

    Science.gov (United States)

    Ahmad, Noor Azizah; Heng, Lee Yook; Salam, Faridah; Hanifah, Sharina Abu

    2018-04-01

    The development of indicator label for detection of total volatile basic nitrogen (TVB-N) is described. Dye extract from edible plants containing anthocyanins was immobilized onto iota-carrageenan as polymer matrix. TVB-N detection worked based on pH increase as the basic deterioration volatile amines generated in the package headspace. Results showed that the indicator label has changed color from blue to green after 12 hours of storage at ambient conditions. The TVB-N value was 38.9648 mg /100 g which is exceeded of acceptability level for seafood products. The pH value of squid flesh has also increased during storage. The colour values of L * and a * negative increases while b* negative decrease with increasing storage time. The indicator label is potentially used as freshness indicator for squid at ambient conditions.

  11. Magnetic evaluation of a solar panel using HTS-SQUID

    Energy Technology Data Exchange (ETDEWEB)

    Kiwa, Toshihiko, E-mail: kiwa@okayama-u.ac.jp; Fukudome, Yohei; Miyazaki, Shingo; Saari, Mohd Mawardi; Sakai, Kenji; Tsukada, Keiji

    2013-11-15

    Highlights: •The magnetic evaluation system of a solar panel using HTS-SQUID has been developed. •The electric circuits made by the discrete devices on the circuit board were visualized. •The electric properties of the commercial solar panels were demonstrated. -- Abstract: The magnetic evaluation system of a solar panel using HTS-SQUID has been proposed and developed. A normal pick-up coil was applied to detect the tangential magnetic field to the panel surface. Since the detected field could be related to the currents of the solar panels, the electric properties of the solar panels could be evaluated. In this work, the evaluation of the electric properties of the commercial solar panels as well as the electric circuits made by the discrete devices on the circuit board was visualized.

  12. Magnetic evaluation of a solar panel using HTS-SQUID

    International Nuclear Information System (INIS)

    Kiwa, Toshihiko; Fukudome, Yohei; Miyazaki, Shingo; Saari, Mohd Mawardi; Sakai, Kenji; Tsukada, Keiji

    2013-01-01

    Highlights: •The magnetic evaluation system of a solar panel using HTS-SQUID has been developed. •The electric circuits made by the discrete devices on the circuit board were visualized. •The electric properties of the commercial solar panels were demonstrated. -- Abstract: The magnetic evaluation system of a solar panel using HTS-SQUID has been proposed and developed. A normal pick-up coil was applied to detect the tangential magnetic field to the panel surface. Since the detected field could be related to the currents of the solar panels, the electric properties of the solar panels could be evaluated. In this work, the evaluation of the electric properties of the commercial solar panels as well as the electric circuits made by the discrete devices on the circuit board was visualized

  13. Coherent arrays of planar dc-SQUIDS based on thin-film Josephson microbridges

    International Nuclear Information System (INIS)

    Hansen, J.B.

    1982-01-01

    Phase-locking and voltage-locking in systems consisting of two planar dc-SQUIDs located close together in the same superconducting film have been investigated. The locking strength was found to be strongly dependent on the fluxoid state of both SQUIDs. A simple model for the inductive coupling between two such dc-SQUIDs is presented and the prediction of the model is compared with the experimental results. (Auth.)

  14. Size increment of jumbo flying squid Dosidicus gigas mature females in Peruvian waters, 1989-2004

    Science.gov (United States)

    Argüelles, Juan; Tafur, Ricardo; Taipe, Anatolio; Villegas, Piero; Keyl, Friedeman; Dominguez, Noel; Salazar, Martín

    2008-10-01

    Changes in population structure of the jumbo flying squid Dosidicus gigas in Peruvian waters were studied based on size-at-maturity from 1989 to 2004. From 1989 to 1999, mature squid belonging to the medium-sized group prevailed, but from 2001 on, mature squids were larger. This change is not related to the changes in sea surface temperature and we hypothesized that it was caused by the population increase of mesopelagic fishes as prey.

  15. Absolute calibration and beam background of the Squid Polarimeter

    International Nuclear Information System (INIS)

    Blaskiewicz, M.M.; Cameron, P.R.; Shea, T.J.

    1996-01-01

    The problem of beam background in Squid Polarimetry is not without residual benefits. The authors may deliberately generate beam background by gently kicking the beam at the spin tune frequency. This signal may be used to accomplish a simple and accurate absolute calibration of the polarimeter. The authors present details of beam background calculations and their application to polarimeter calibration, and suggest a simple proof-of-principle accelerator experiment

  16. Symplectin evolved from multiple duplications in bioluminescent squid

    DEFF Research Database (Denmark)

    Francis, Warren R.; Christianson, Lynne M.; Haddock, Steven H.D.

    2017-01-01

    The squid Sthenoteuthis oualaniensis, formerly Symplectoteuthis oualaniensis, generates light using the luciferin coelenterazine and a unique enzyme, symplectin. Genetic information is limited for bioluminescent cephalopod species, so many proteins, including symplectin, occur in public databases...... functioning is conserved across essentially all members of the protein family, even those unlikely to be used for bioluminescence. Conversely, active site residues involved in pantetheinase catalysis are also conserved across essentially all of these proteins, suggesting that symplectin may have multiple...

  17. Antibacterial Activity of Melanin from Cuttlefish and Squid Ink

    OpenAIRE

    Yuspihana Fitrial; Iin Khusnul Khotimah

    2017-01-01

    Marine environment comprises of many organism which are known to posses bioactive compound as a common means of self-defense or for the protection of eggs and embryos. Class Cephalopods (such as squidand cuttlefish) are notable for their defences, such as jetting escape movements, changes in colouration, toxic venom and inking.This study aims to compare the antibacterial activity of melanin from cuttlefish ink (Sepia sp.) with squid ink (Loligo sp.) against E. coli. Extraction and purificatio...

  18. Detecting damage in steel with scanning SQUID microscopy

    International Nuclear Information System (INIS)

    Lee, Tae-Kyu; Clatterbuck, D.M.; Morris, J.W. Jr.; Shaw, T.J.; Lee, Seungkyun; Clarke, John

    2002-01-01

    A 'Holy Grail' of NDE research is a non-destructive method for measuring fatigue damage prior to crack initiation. High-Tc scanning SQUID microscopy may be a useful tool. Because of the exceptional magnetic sensitivity of this technique, fatigue damage can be detected well before microcrack initiation, and in the absence of other obvious microstructure or property changes. Given the spatial resolution of the technique, undamaged material can be located and used to set internal standards

  19. Detecting damage in steel with scanning SQUID microscopy

    International Nuclear Information System (INIS)

    Lee, Tae-Kyu; Clatterbuck, David; Morris Jr., J.W.; Shaw, T.J.; McDermott R.; Clarke, John

    2001-01-01

    A ''Holy Grail'' of NDE research is a non-destructive method for measuring fatigue damage prior to crack initiation. High-Tc scanning SQUID microscopy may be a useful tool. Because of the exceptional magnetic sensitivity of this technique, fatigue damage can be detected well before microcrack initiation, and in the absence of other obvious microstructure or property changes. Given the spatial resolution of the technique, undamaged material can be located and used to set internal standards

  20. Development and validation of Dutch version of Lasater Clinical Judgment Rubric in hospital practice: An instrument design study.

    Science.gov (United States)

    Vreugdenhil, Jettie; Spek, Bea

    2018-03-01

    Clinical reasoning in patient care is a skill that cannot be observed directly. So far, no reliable, valid instrument exists for the assessment of nursing students' clinical reasoning skills in hospital practice. Lasater's clinical judgment rubric (LCJR), based on Tanner's model "Thinking like a nurse" has been tested, mainly in academic simulation settings. The aim is to develop a Dutch version of the LCJR (D-LCJR) and to test its psychometric properties when used in a hospital traineeship context. A mixed-model approach was used to develop and to validate the instrument. Ten dedicated educational units in a university hospital. A well-mixed group of 52 nursing students, nurse coaches and nurse educators. A Delphi panel developed the D-LCJR. Students' clinical reasoning skills were assessed "live" by nurse coaches, nurse educators and students who rated themselves. The psychometric properties tested during the assessment process are reliability, reproducibility, content validity and construct validity by testing two hypothesis: 1) a positive correlation between assessed and self-reported sum scores (convergent validity) and 2) a linear relation between experience and sum score (clinical validity). The obtained D-LCJR was found to be internally consistent, Cronbach's alpha 0.93. The rubric is also reproducible with intraclass correlations between 0.69 and 0.78. Experts judged it to be content valid. The two hypothesis were both tested significant, supporting evidence for construct validity. The translated and modified LCJR, is a promising tool for the evaluation of nursing students' development in clinical reasoning in hospital traineeships, by students, nurse coaches and nurse educators. More evidence on construct validity is necessary, in particular for students at the end of their hospital traineeship. Based on our research, the D-LCJR applied in hospital traineeships is a usable and reliable tool. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. SQUID sensor application for small metallic particle detection

    International Nuclear Information System (INIS)

    Tanaka, Saburo; Hatsukade, Yoshimi; Ohtani, Takeyoshi; Suzuki, Shuichi

    2009-01-01

    High-Tc superconducting quantum interference device (SQUID) is an ultra-sensitive magnetic sensor. Since the performance of the SQUID is improved and stabilized, now it is ready for application. One strong candidate for application is a detection system of magnetic foreign matters in industrial products or beverages. There is a possibility that ultra-small metallic foreign matter has been accidentally mixed with industrial products such as lithium ion batteries. If this happens, the manufacturer of the product suffers a great loss recalling products. The outer dimension of metallic particles less than 100 μm cannot be detected by an X-ray imaging, which is commonly used for the inspection. Ionization of the material is also a big issue for beverages in the case of the X-ray imaging. Therefore a highly sensitive and safety detection system for small foreign matters is required. We developed detection systems based on high-Tc SQUID with a high-performance magnetic shield. We could successfully measure small iron particles of 100 μm on a belt conveyer and stainless steel balls of 300 μm in water. These detection levels were hard to be achieved by a conventional X-ray detection or other methods

  2. Simulation and optimization of a dc SQUID with finite capacitance

    Energy Technology Data Exchange (ETDEWEB)

    de Waal, V.J.; Schrijner, P.; Llurba, R.

    1984-02-01

    This paper deals with the calculations of the noise an the optimization of the energy resolution of a dc SQUID with finite junction capacitance. Up to now noise calculations of dc SQUIDs were performed using a model without parasitic capacitances across the Josephson junctions. As the capacitances limit the performance of the SQUID, for a good optimization one must take them into account. The model consists of two coupled nonlinear second-order differential equations. The equations are very suitable for simulation with an analog circuit. We implemented the model on a hybrid computer. The noise spectrum from the model is calculated with a fast Fourier transform. A calculation of the energy resolution for one set of parameters takes about 6 min of computer time. Detailed results of the optimization are given for products of inductance and temperature of LT = 1.2 and 5 nHK. Within a range of ..beta.. and ..beta../sub c/ between 1 and 2, which is optimum, the energy resolution is nearly independent of these variables. In this region the energy resolution is near the value calculated without parasitic capacitances. Results of the optimized energy resolution are given as a function of LT between 1.2 and 10 nHK.

  3. Simulation and optimization of a dc SQUID with finite capacitance

    Science.gov (United States)

    de Waal, V. J.; Schrijner, P.; Llurba, R.

    1984-02-01

    This paper deals with the calculations of the noise and the optimization of the energy resolution of a dc SQUID with finite junction capacitance. Up to now noise calculations of dc SQUIDs were performed using a model without parasitic capacitances across the Josephson junctions. As the capacitances limit the performance of the SQUID, for a good optimization one must take them into account. The model consists of two coupled nonlinear second-order differential equations. The equations are very suitable for simulation with an analog circuit. We implemented the model on a hybrid computer. The noise spectrum from the model is calculated with a fast Fourier transform. A calculation of the energy resolution for one set of parameters takes about 6 min of computer time. Detailed results of the optimization are given for products of inductance and temperature of LT=1.2 and 5 nH K. Within a range of β and β c between 1 and 2, which is optimum, the energy resolution is nearly independent of these variables. In this region the energy resolution is near the value calculated without parasitic capacitances. Results of the optimized energy resolution are given as a function of LT between 1.2 and 10 mH K.

  4. Transfer of 60Co from midwater squid to sperm whales

    International Nuclear Information System (INIS)

    Umezu, Takeshi; Minamisako, Yoko; Ebihara, Hiroshi; Watanabe, Hiroshi.

    1984-01-01

    Sperm whales are notable squid-eaters. They feed mainly on medium to large-sized cephalopods at midwater levels and defecate near the surface. This suggests the existence of an upward transport of 60 Co by sperm whales from the mesopelagic zone (150-1,200m). To elucidate this squid-whale route for this artificial radionuclide, 60 Co content was determined in squid and in predator whales captured by commercial whaling. In the Cephalopoda livers 60 Co levels of 30-500 mBq kg -1 wet were found and in the viscera of Odontoceti (toothed whales) 15-40 mBq kg -1 wet. About 0.3% of 60 Co ingested was estimated to be retained in a 23-year-old male sperm whale. In the livers of Bryde's whales, 60 Co levels of 40-80 mBq kg -1 wet were detected, but not in euphausiids and sardines, their possible prey. The level of Co in sperm whales was nearly the same as in Bryde's whales. Specific radioactivity 60 Co/ 59 Co in mBq μg -1 was several times higher in sperm whale (1.1-1.6) than in cephalopods (0.19-0.77). Eating prey with a high content of 60 Co in the 1960's may have contributed to the present body burden in sperm whales with a long-life span. However, the origin of 60 Co in Bryde's whales is unknown. (author)

  5. Thermoelectric SQUID method for the detection of segregations

    Science.gov (United States)

    Hinken, Johann H.; Tavrin, Yury

    2000-05-01

    Aero engine turbine discs are most critical parts. Material inhomogeneities can cause disc fractures during the flight with fatal air disasters. Nondestructive testing (NDT) of the discs in various machining steps is necessary and performed as well as possible. Conventional NDT methods, however, like eddy current testing and ultrasonic testing have unacceptable limits. For example, subsurface segregations often cannot be detected directly but only indirectly in such cases when cracks already have developed from them. This may be too late. A new NDT method, which we call the Thermoelectric SQUID Method, has been developed. It allows for the detection of metallic inclusions within non-ferromagnetic metallic base material. This paper describes the results of a feasibility study on aero engine turbine discs made from Inconel® 718. These contained segregations that had been detected before by anodic etching. With the Thermoelectric SQUID Method, these segregations were detected again, and further segregations below the surfaces have been found, which had not been detected before. For this new NDT method the disc material is quasi-transparent. The Thermoelectric SQUID Method is also useful to detect distributed and localized inhomogeneities in pure metals like niobium sheets for particle accelerators.

  6. Low-frequency nuclear quadrupole resonance with a dc SQUID

    International Nuclear Information System (INIS)

    Chang, J.W.

    1991-07-01

    Conventional pure nuclear quadrupole resonance (NQR) is a technique well suited for the study of very large quadrupolar interactions. Numerous nuclear magnetic resonance (NMR) techniques have been developed for the study of smaller quadrupolar interactions. However, there are many nuclei which have quadrupolar interactions of intermediate strength. Quadrupolar interactions in this region have traditionally been difficult or unfeasible to detect. This work describes the development and application of a SQUID NQR technique which is capable of measuring intermediate strength quadrupolar interactions, in the range of a few hundred kilohertz to several megahertz. In this technique, a dc SQUID (Superconducting QUantum Interference Device) is used to monitor the longitudinal sample magnetization, as opposed to the transverse magnetization, as a rf field is swept in frequency. This allows the detection of low-frequency nuclear quadrupole resonances over a very wide frequency range with high sensitivity. The theory of this NQR technique is discussed and a description of the dc SQUID system is given. In the following chapters, the spectrometer is discussed along with its application to the study of samples containing half-odd-integer spin quadrupolar nuclei, in particular boron-11 and aluminum-27. The feasibility of applying this NQR technique in the study of samples containing integer spin nuclei is discussed in the last chapter. 140 refs., 46 figs., 6 tabs

  7. SQUID-based noise thermometer for sub-Millikelvin refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Marco; Beyer, Joern; Klemm, Monique [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany); Alivaliollahi, Sassan; Barthelmess, Henry [Magnicon GmbH, Barkhausenweg 11, 22339 Hamburg (Germany)

    2015-07-01

    The magnetic field fluctuation thermometer (MFFT) is a high-accuracy SQUID-based noise thermometer suitable for sub-Kelvin thermometry. A highly sensitive low-Tc SQUID magnetometer detects inductively the magnetic field fluctuation above a metal surface. The fluctuations are generated by the thermal activated noise currents inside the metal body that is thermally anchored to the temperature stage to be measured. The spectral shape is independent of temperature as the electrical conductivity is constant and the geometry is fixed. The magnetic noise power spectral amplitudes at any frequencies are directly proportional to temperature. Hence, only one reference measurement at a known temperature is required for calibration. A complete MFFT thermometer system for the temperature range of ca. 4 K down to <10 mK is commercially available. We have now developed an integrated MFFT with an extended range of operation down to <1 mK. For this purpose the sensitivity of the SQUID sensor has been increased, the metal body geometry modified and the magnetic shielding of the MFFT module improved. These modifications make it possible to obtain a thermometer noise temperature of <10 μK. We discuss the rationale for our MFFT configuration and present numerical simulations and experimental results.

  8. Trophic niche of squids: Insights from isotopic data in marine systems worldwide

    Science.gov (United States)

    Navarro, Joan; Coll, Marta; Somes, Christoper J.; Olson, Robert J.

    2013-10-01

    Cephalopods are an important prey resource for fishes, seabirds, and marine mammals, and are also voracious predators on crustaceans, fishes, squid and zooplankton. Because of their high feeding rates and abundance, squids have the potential to exert control on the recruitment of commercially important fishes. In this review, we synthesize the available information for two intrinsic markers (δ15N and δ13C isotopic values) in squids for all oceans and several types of ecosystems to obtain a global view of the trophic niches of squids in marine ecosystems. In particular, we aimed to examine whether the trophic positions and trophic widths of squid species vary among oceans and ecosystem types. To correctly compare across systems, we adjusted squid δ15N values for the isotopic variability of phytoplankton at the base of the food web provided by an ocean circulation-biogeochemistry-isotope model. Studies that focused on the trophic ecology of squids using isotopic techniques were few, and most of the information on squids was from studies on their predators. Our results showed that squids occupy a large range of trophic positions and exploit a large range of trophic resources, reflecting the versatility of their feeding behavior and confirming conclusions from food-web models. Clear differences in both trophic position and trophic width were found among oceans and ecosystem types. The study also reinforces the importance of considering the natural variation in isotopic values when comparing the isotopic values of consumers inhabiting different ecosystems.

  9. Measurement Instrument for Scientific Teaching (MIST): A Tool to Measure the Frequencies of Research-Based Teaching Practices in Undergraduate Science Courses.

    Science.gov (United States)

    Durham, Mary F; Knight, Jennifer K; Couch, Brian A

    2017-01-01

    The Scientific Teaching (ST) pedagogical framework provides various approaches for science instructors to teach in a way that more closely emulates how science is practiced by actively and inclusively engaging students in their own learning and by making instructional decisions based on student performance data. Fully understanding the impact of ST requires having mechanisms to quantify its implementation. While many useful instruments exist to document teaching practices, these instruments only partially align with the range of practices specified by ST, as described in a recently published taxonomy. Here, we describe the development, validation, and implementation of the Measurement Instrument for Scientific Teaching (MIST), a survey derived from the ST taxonomy and designed to gauge the frequencies of ST practices in undergraduate science courses. MIST showed acceptable validity and reliability based on results from 7767 students in 87 courses at nine institutions. We used factor analyses to identify eight subcategories of ST practices and used these categories to develop a short version of the instrument amenable to joint administration with other research instruments. We further discuss how MIST can be used by instructors, departments, researchers, and professional development programs to quantify and track changes in ST practices. © 2017 M. F. Durham et al. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  10. Development of an item bank for food parenting practices based on published instruments and reports from Canadian and U.S. parents

    Science.gov (United States)

    Research to understand how parents influence their children's dietary intake and eating behaviors has expanded in the past decades and a growing number of instruments are available to assess food parenting practices. Unfortunately, there is no consensus on how constructs should be defined or operati...

  11. 76 FR 68642 - Fisheries of the Northeastern United States; Atlantic Mackerel, Squid, and Butterfish Fisheries...

    Science.gov (United States)

    2011-11-07

    ... update to essential fish habitat designations for all life stages of mackerel, longfin squid, Illex squid... issued a mackerel permit may not fish for, possess, or land more than 20,000 lb (9.08 mt) of mackerel per trip, and that, during any closure that occurs after June 1, vessels may not fish for, possess, or land...

  12. Noise characteristics of a dc SQUID with a resistively shunted inductance

    International Nuclear Information System (INIS)

    Enpuku, K.; Muta, T.; Yoshida, K.; Irie, F.

    1985-01-01

    Noise characteristics of a dc SQUID with an inductance shunted by a damping resistance are studied numerically. It is shown that the damping resistance improves considerably the resolution of the SQUID in the case of large β, where β = 2LI 0 /Phi 0 , I 0 is a critical current, L is a loop inductance and Phi 0 is the flux quantum. The energy resolutions for β = 4 and β = 10 are only about 2 and 4 times larger than that for β = 1, respectively. Furthermore, the ranges of both the bias current and the external flux, where good resolution is obtained, become very wide compared with the conventional SQUID. Therefore, the SQUID with the damping resistance can be used for large β (or L) without the significant degradation of the resolution, and will much improve the coupling properties between the SQUID and the input circuitry. The numerical simulation results are also compared with analytical ones, and a reasonable agreement is obtained

  13. Low-frequency flux noise in YBCO dc SQUIDs cooled in static magnetic fields

    International Nuclear Information System (INIS)

    Sager, M.P.; Bindslev Hansen, J.; Petersen, P.R.E.; Holst, T.; Shen, Y.Q.

    1999-01-01

    The low-frequency flux noise in bicrystal and step-edge YBa 2 Cu 3 O x dc SQUIDs has been investigated. The width, w, of the superconducting strips forming the SQUID frame was varied from 4 to 42 μm. The SQUIDs were cooled in static magnetic fields up to 150 μT. Two types of low-frequency noise dominated, namely 1/f-like noise and random telegraph noise giving a Lorentzian frequency spectrum. The 1/f noise performance of the w = 4, 6 and 7 μm SQUIDs was almost identical, while the SQUIDs with w = 22 and 42 μm showed an order of magnitude higher noise level. Our analysis of the data suggests an exponential increase of the 1/f noise versus the cooling field, exhibiting a characteristic magnetic field around 40 μT. (author)

  14. Temperature dependence of the effective sensing area of high-Tc dc SQUIDs

    International Nuclear Information System (INIS)

    Brake, H.J.M. ter; Aarnink, W.A.M.; Bosch, P.J. van den; Hilgenkamp, J.W.M.; Flokstra, J.; Rogalla, H.

    1997-01-01

    The effective sensing area of a high-T c dc SQUID depends on temperature. As a consequence, fluctuations in the operating temperature result in apparent magnetic field noise if the SQUID is placed in a background magnetic field. An analysis of this effect for two SQUID types, the square-washer 'Ketchen' type and the inductively shunted type, is performed. For magnetocardiography, the temperature fluctuations (peak to peak) of the latter SQUID type should be below w 0.3 mK at 77 K, and below 2 mK at 55 K, with an earth's field suppression of 40 dB. For the square-washer SQUID the requirements are about 8 times less stringent. (author)

  15. Observance of Sterilization Protocol Guideline Procedures of Critical Instruments for Preventing Iatrogenic Transmission of Creutzfeldt-Jakob Disease in Dental Practice in France, 2017

    Directory of Open Access Journals (Sweden)

    Denis Bourgeois

    2018-04-01

    Full Text Available Effective sterilization of reusable instruments contaminated by Creutzfeldt–Jakob disease in dental care is a crucial issue for public health. The present cross-sectional study investigated how the recommended procedures for sterilization were implemented by French dental practices in real-world settings. A sample of dental practices was selected in the French Rhône-Alpes region. Data were collected by a self-questionnaire in 2016. Sterilization procedures (n = 33 were classified into 4 groups: (1 Pre-sterilization cleaning of reusable instruments; (2 Biological verification of sterilization cycles—Monitoring steam sterilization procedures; (3 Autoclave performance and practitioner knowledge of autoclave use; (4 Monitoring and documentation of sterilization procedures—Tracking and tracing the instrumentation. Answers were provided per procedure, along with the global implementation of procedures within a group (over 80% correctly performed. Then it was verified how adherence to procedure groups varied with the size of the dental practice and the proportion of dental assistants within the team. Among the 179 questionnaires available for the analyses, adherence to the recommended procedures of sterilization noticeably varied between practices, from 20.7% to 82.6%. The median percentages of procedures correctly implemented per practice were 58.1%, 50.9%, 69.2% and 58.2%, in Groups 1, 2, 3 and 4, respectively (corresponding percentages for performing over 80% of the procedures in the group: 23.4%, 6.6%, 46.6% and 38.6%. Dental practices ≥ 3 dental units performed significantly better (>80% procedures of Groups 2 and 4 (p = 0.01 and p = 0.002, respectively, while no other significant associations emerged. As a rule, practices complied poorly with the recommended procedures, despite partially improved results in bigger practices. Specific training regarding sterilization procedures and a better understanding of the reasons leading to their

  16. Issues relating to airborne applications of HTS SQUIDs

    CERN Document Server

    Foley, C P; Binks, R A; Lam, S H K; Du, J; Tilbrook, D L; Mitchell, E E; MacFarlane, J C; Lee, J B; Turner, R; Downey, M; Maddever, A

    2002-01-01

    Airborne application of HTS SQUIDs is the most difficult environment for their successful deployment. In order to operate with the sensitivity required for a particular application, there are many issues to be addressed such as the need for very wide dynamic range electronics, motion noise elimination, immunity to large changing magnetic fields and cultural noise sources. This paper reviews what is necessary to achieve an airborne system giving examples in geophysical mineral exploration. It will consider issues relating to device design and fabrication, electronics, dewar design, suspension system requirements and noise elimination methods.

  17. Quantum versus thermally excited fluxoid transitions in a SQUID ring

    International Nuclear Information System (INIS)

    Kurkijaervi, J.

    1980-01-01

    The possibility of quantum tunneling as a mechanism for fluxoid transitions in a SQUID ring is carefully considered neglecting, however, dissipation arising from the quasiparticle current. The tunneling rates are compared with the thermally excited transition rates. The type of experiment Jackel et al. carried out in order to observe the thermal process is analyzed for observing the quantum tunneling. We find the expected result that the temperature at which the quantum process should begin to dominate depends essentially on ω 0 = 1/√LC of the ring. If an underdamped junction with C -13 F can be made the quantum tunneling temperature range should be easy to attain. (orig.)

  18. 3D Inversion of SQUID Magnetic Tensor Data

    DEFF Research Database (Denmark)

    Zhdanov, Michael; Cai, Hongzhu; Wilson, Glenn

    2012-01-01

    Developments in SQUID-based technology have enabled direct measurement of magnetic tensor data for geophysical exploration. For quantitative interpretation, we introduce 3D regularized inversion for magnetic tensor data. For mineral exploration-scale targets, our model studies show that magnetic...... tensor data have significantly improved resolution compared to magnetic vector data for the same model. We present a case study for the 3D regularized inversion of magnetic tensor data acquired over a magnetite skarn at Tallawang, Australia. The results obtained from our 3D regularized inversion agree...

  19. Issues relating to airborne applications of HTS SQUIDs

    International Nuclear Information System (INIS)

    Foley, C P; Leslie, K E; Binks, R A; Lam, S H K; Du, J; Tilbrook, D L; Mitchell, E E; Macfarlane, J C; Lee, J B; Turner, R; Downey, M; Maddever, A

    2002-01-01

    Airborne application of HTS SQUIDs is the most difficult environment for their successful deployment. In order to operate with the sensitivity required for a particular application, there are many issues to be addressed such as the need for very wide dynamic range electronics, motion noise elimination, immunity to large changing magnetic fields and cultural noise sources. This paper reviews what is necessary to achieve an airborne system giving examples in geophysical mineral exploration. It will consider issues relating to device design and fabrication, electronics, dewar design, suspension system requirements and noise elimination methods

  20. Thermal activation and macroscopic quantum tunneling in a DC SQUID

    International Nuclear Information System (INIS)

    Sharifi, F.; Gavilano, J.L.; VanHarlingen, D.J.

    1989-01-01

    The authors report measurements of the transition rate from metastable minima in the two-dimensional 1 of a dc SQUID as a function of applied flux temperature. The authors observe a crossover from energy-activated escape to macroscopic quantum tunneling at a critical temperature. The macroscopic quantum tunneling rate is substantially reduced by damping, and also broadens the crossover region. Most interestingly, the authors observe thermal rates that are suppressed from those predicted by the two-dimensional thermal activation model. The authors discuss possible explanations for this based on the interaction of the macroscopic degree of freedom in the device and energy level effects

  1. Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

    Science.gov (United States)

    Chesca, Boris; John, Daniel; Mellor, Christopher J.

    2015-10-01

    A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise SΦ1/2 decreases as 1/N1/2. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa2Cu3O7. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for SΦ1/2 between (0.25 and 0.44) μΦ0/Hz1/2 for temperatures in the range (77-83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10-17) mV and (0.3-2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

  2. SQUID readout multiplexers for transition-edge sensor arrays

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Adrian T. [Physics Department, University of California, Berkeley, CA 94720 (United States) and Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)]. E-mail: atl@physics.berkeley.edu

    2006-04-15

    Two classes of SQUID multiplexer are being developed for large arrays of cryogenic sensors, distinguished by their operation in either the time domain or frequency domain. Several systems optimized for use with Transition-Edge Sensors (TES) are reaching a high level of maturity, and will be deployed on funded astrophysics experiments in the next several years. A useful technical figure of merit is the product of the number of detectors multplexed multipled by the bandwidth of the detectors, which can be termed the 'total signal bandwidth' of a multiplexer system. This figure of merit is comparable within a factor of two for the mature systems. Several new concepts for increasing the total bandwidth are being developed in the broad class of frequency domain multiplexers. Another notable area of progress is in the level of integration of muliplexer and detector array. The time domain system for SCUBA-II is a sophisticated bump-bonded sandwich structure, and the Jena/MPI group is integrating detectors and a time domain multiplexer on one substrate. Finally, the Kinetic Inductance Detectors (KID)/HEMT (non-SQUID) detector/multiplexer system, will be discussed briefly.

  3. Antibacterial Activity of Melanin from Cuttlefish and Squid Ink

    Directory of Open Access Journals (Sweden)

    Yuspihana Fitrial

    2017-08-01

    Full Text Available Marine environment comprises of many organism which are known to posses bioactive compound as a common means of self-defense or for the protection of eggs and embryos. Class Cephalopods (such as squidand cuttlefish are notable for their defences, such as jetting escape movements, changes in colouration, toxic venom and inking.This study aims to compare the antibacterial activity of melanin from cuttlefish ink (Sepia sp. with squid ink (Loligo sp. against E. coli. Extraction and purification studies were carried out on Sepia and Loligo melanin using a hydrochloric acid 0,5M treatment under mechanical.The melanins were obtained and further evaluated their activity by direct contact methods between melanin and E. coli in nutrient broth.Total microbes was counted by total plate count.Both inks also was tested their activity against E. coli. The results showed that melanin from cuttlefish and squid inks had inhibitory activity at concentrations of 10 mg / ml and 20 mg / mL, respectively reaching 99.99% against E. coli.The inks of both Cephalopods at the same concentration as melanin, did not show any inhibitory activity against E. coli.  The melanin of Sepia sp. have a higher antibacterial activity than the melanin of Loligo sp.

  4. Reduction of environmental MHz noise for SQUID application

    Energy Technology Data Exchange (ETDEWEB)

    Araya, T. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)]. E-mail: araya@sup.ee.es.osaka-u.ac.jp; Kitamura, Y. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Kamishiro, M. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Sakuta, K. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan); Itozaki, H. [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)]. E-mail: itozaki@ee.es.osaka-u.ac.jp

    2006-10-01

    It is important to remove large environmental noise in measurement using SQUIDs without magnetic shielding. Active noise control (ANC) is an effective method to remove the environmental noise. The environmental noise has been reduced by the ANC system in the radio frequency region around MHz. The anti-phase waves of the environmental noise should be generated by this system. The ANC system including the phase and amplitude control circuit was developed to make the anti-phase waves in the MHz region. In this paper, sinusoidal waves with a MHz frequency were used as the environmental noise. When a coil antenna was used for a receiver antenna, this ANC system suppressed these sinusoidal waves to the white noise level about 40 dB. When we used a SQUID as a receiver antenna, we also cancelled sinusoidal waves to the white noise level by this system. This shows that the ANC system is useful to reduce an environmental noise when this ANC system is developed to cancel multi-frequency noise.

  5. Reduction of environmental MHz noise for SQUID application

    International Nuclear Information System (INIS)

    Araya, T.; Kitamura, Y.; Kamishiro, M.; Sakuta, K.; Itozaki, H.

    2006-01-01

    It is important to remove large environmental noise in measurement using SQUIDs without magnetic shielding. Active noise control (ANC) is an effective method to remove the environmental noise. The environmental noise has been reduced by the ANC system in the radio frequency region around MHz. The anti-phase waves of the environmental noise should be generated by this system. The ANC system including the phase and amplitude control circuit was developed to make the anti-phase waves in the MHz region. In this paper, sinusoidal waves with a MHz frequency were used as the environmental noise. When a coil antenna was used for a receiver antenna, this ANC system suppressed these sinusoidal waves to the white noise level about 40 dB. When we used a SQUID as a receiver antenna, we also cancelled sinusoidal waves to the white noise level by this system. This shows that the ANC system is useful to reduce an environmental noise when this ANC system is developed to cancel multi-frequency noise

  6. Temperature-dependent performance of all-NbN DC-SQUID magnetometers

    Science.gov (United States)

    Liu, Quansheng; Wang, Huiwu; Zhang, Qiyu; Wang, Hai; Peng, Wei; Wang, Zhen

    2017-05-01

    Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current-voltage and voltage-flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.

  7. Development of an image processing system in splendid squid quality classification

    Science.gov (United States)

    Masunee, Niyada; Chaiprapat, Supapan; Waiyagan, Kriangkrai

    2013-07-01

    Agricultural products typically exhibit high variance in quality characteristics. To assure customer satisfaction and control manufacturing productivity, quality classification is necessary to screen off defective items and to grade the products. This article presents an application of image processing techniques on squid grading and defect discrimination. A preliminary study indicated that surface color was an efficient determinant to justify quality of splendid squids. In this study, a computer vision system (CVS) was developed to examine the characteristics of splendid squids. Using image processing techniques, squids could be classified into three different quality grades as in accordance with an industry standard. The developed system first sifted through squid images to reject ones with black marks. Qualified squids were graded on a proportion of white, pink, and red regions appearing on their bodies by using fuzzy logic. The system was evaluated on 100 images of squids at different quality levels. It was found that accuracy obtained by the proposed technique was 95% compared with sensory evaluation of an expert.

  8. Sensitive YBCO nanoSQUIDs for the investigation of small spin systems

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Benedikt; Schwarz, Tobias; Woelbing, Roman; Martinez-Perez, Maria Jose; Kleiner, Reinhold; Koelle, Dieter [Tuebingen Univ. (Germany). Physikalisches Inst. and Center for Collective Quantum Phenomena in LISA+; Reiche, Christopher F.; Muehl, Thomas; Buechner, Bernd [Leibniz Institute for Solid State and Materials Research IFW Dresden (Germany)

    2015-07-01

    We report on advances in the realization of dc YBCO nanoSQUIDs for continuous measurement of magnetic nanoparticle magnetization loops in strong magnetic fields up to the Tesla range, applied in the plane of the SQUID loop at temperatures of 4 K and below. Our grain boundary junction based YBCO SQUIDs are patterned by focused ion beam milling and feature a constriction next to the SQUID loop, allowing for on-chip SQUID modulation and bias reversal readout schemes. Using numerical simulations based on London theory, the spin sensitivity S{sub μ}{sup 1/2} = S{sub Φ}{sup 1/2} / φ{sub μ} was improved by optimizing both the flux noise S{sub Φ}{sup 1/2} and the coupling factor φ{sub μ} = Φ / μ (Φ is the magnetic flux coupled into the SQUID loop by a particle with magnetic moment μ). For optimized experimental devices, flux noise levels down to 50 nΦ{sub 0} / Hz{sup 1/2} in the white noise limit have been achieved, corresponding to a calculated spin sensitivity of only a few μ{sub B} / Hz{sup 1/2}. Further, the magnetization reversal of a Fe filled carbon nanotube attached to a YBCO nanoSQUID was traced out.

  9. Characteristics of an HTS-SQUID gradiometer with ramp-edge Josephson junctions and its application on robot-based 3D-mobile compact SQUID NDE system

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukade, Y., E-mail: hatukade@ens.tut.ac.jp [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan); Hayashi, K.; Shinyama, Y.; Kobayashi, Y. [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan); Adachi, S.; Tanabe, K. [International Superconductivity Technology Center/Superconductivity Research Laboratory, 10-13, Shinonome 1-chome, Koto-ku, Tokyo 135-0062 (Japan); Tanaka, S. [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2011-11-15

    We investigated behavior of HTS-dc-SQUID gradiometers with ramp-edge Josephson junctions (JJs) in ac and dc magnetic fields. In the both fields, the gradiometers show higher durability against entry of flux vortices than SQUIDs with bicrystal JJs. A robot-based SQUID NDE system utilizing the gradiometer was developed in an unshielded environment. Detectability of the system to detect non-through cracks in double-layer structures was demonstrated. A new excitation coil was applied to detect cracks that oriented vertical and parallel to the baseline of the gradiometer. In this paper, we investigated detailed behavior of novel HTS-dc-SQUID gradiometers with ramp-edge Josephson junctions (JJs) in both an ac magnetic field and a dc magnetic field. In the both fields, the novel gradiometers shows the superior performance to the conventional YBa{sub 2}Cu{sub 3}O{sub 7-x} (YBCO) HTS-dc-SQUID gradiometer and a bare HTS-dc-SQUID ring with bicrystal JJs concerning durability against entry and hopping of flux vortices, probably due to their differential pickup coils without a grain boundary and multilayer structure of the ramp-edge JJs. A robot-based compact HTS-SQUID NDE system utilizing the novel gradiometer was reviewed, and detectability of the system to detect non-through cracks in a carbon fiber reinforced plastic (CFRP)/Al double-layer structure was demonstrated. A new excitation coil in which the supplied currents flowed in the orthogonal directions was applied to detect cracks that oriented vertical and parallel to the baseline of the gradiometer.

  10. Radio frequency interference noise reduction using a field programmable gate array for SQUID applications

    International Nuclear Information System (INIS)

    Sakuta, K; Narita, Y; Itozaki, H

    2007-01-01

    It is important to remove large environmental noise in superconducting quantum interference device (SQUID) measurement without magnetic shielding. Active noise control (ANC) is one of the effective methods to reduce environmental noise. Recently, SQUIDs have been used in various applications at high frequencies, such as nuclear quadrupole resonance (NQR). The NQR frequency from explosives is in the range 0.5-5 MHz. In this case, an NQR sensor is exposed to AM radio frequency interference (RFI). The feasibility of the ANC system for RFI that used digital signal processing was studied. Our investigation showed that this digital ANC system can be applied to SQUID measurements for RFI suppression

  11. Mismatch between the eye and the optic lobe in the giant squid.

    Science.gov (United States)

    Liu, Yung-Chieh; Liu, Tsung-Han; Yu, Chun-Chieh; Su, Chia-Hao; Chiao, Chuan-Chin

    2017-07-01

    Giant squids ( Architeuthis ) are a legendary species among the cephalopods. They live in the deep sea and are well known for their enormous body and giant eyes. It has been suggested that their giant eyes are not adapted for the detection of either mates or prey at distance, but rather are best suited for monitoring very large predators, such as sperm whales, at distances exceeding 120 m and at a depth below 600 m (Nilsson et al. 2012 Curr. Biol. 22 , 683-688. (doi:10.1016/j.cub.2012.02.031)). However, it is not clear how the brain of giant squids processes visual information. In this study, the optic lobe of a giant squid ( Architeuthis dux , male, mantle length 89 cm), which was caught by local fishermen off the northeastern coast of Taiwan, was scanned using high-resolution magnetic resonance imaging in order to examine its internal structure. It was evident that the volume ratio of the optic lobe to the eye in the giant squid is much smaller than that in the oval squid ( Sepioteuthis lessoniana ) and the cuttlefish ( Sepia pharaonis ). Furthermore, the cell density in the cortex of the optic lobe is significantly higher in the giant squid than in oval squids and cuttlefish, with the relative thickness of the cortex being much larger in Architeuthis optic lobe than in cuttlefish. This indicates that the relative size of the medulla of the optic lobe in the giant squid is disproportionally smaller compared with these two cephalopod species. This morphological study of the giant squid brain, though limited only to the optic lobe, provides the first evidence to support that the optic lobe cortex, the visual information processing area in cephalopods, is well developed in the giant squid. In comparison, the optic lobe medulla, the visuomotor integration centre in cephalopods, is much less developed in the giant squid than other species. This finding suggests that, despite the giant eye and a full-fledged cortex within the optic lobe, the brain of giant

  12. jSquid: a Java applet for graphical on-line network exploration.

    Science.gov (United States)

    Klammer, Martin; Roopra, Sanjit; Sonnhammer, Erik L L

    2008-06-15

    jSquid is a graph visualization tool for exploring graphs from protein-protein interaction or functional coupling networks. The tool was designed for the FunCoup web site, but can be used for any similar network exploring purpose. The program offers various visualization and graph manipulation techniques to increase the utility for the user. jSquid is available for direct usage and download at http://jSquid.sbc.su.se including source code under the GPLv3 license, and input examples. It requires Java version 5 or higher to run properly. erik.sonnhammer@sbc.su.se Supplementary data are available at Bioinformatics online.

  13. Frequency-domain multiplex with eight-input SQUID and readout electronics over 1MHz

    International Nuclear Information System (INIS)

    Masui, K.; Takei, Y.; Ikeda, H.; Kimura, S.; Mitsuda, K.; Yamasaki, N.Y.

    2006-01-01

    In a magnetic summation method, TES and SQUID driving circuits are isolated and thus small crosstalk and stray impedance are expected. Since a FLL circuit with a large bandwidth and a small noise level is required for a SQUID, we designed and produced an electronics to meet our design of multiplexing with an 8-input SQUID. The FLL circuit achieved an open loop-gain bandwidth product of 8MHz with 1m wire length, which is enough for a TES to be operated with a bias current of 70μA, and a noise level of 30pA/Hz

  14. Step edge Josephson junctions and high temperature superconducting quantum interference device (SQUID) gradiometers

    International Nuclear Information System (INIS)

    Millar, Alasdair J.

    2002-01-01

    This thesis is concerned with the development of Superconducting Quantum Interference Device (SQUID) gradiometers based on the high temperature superconductor YBa 2 Cu 3 O 7-δ (YBCO). A step-edge Josephson junction fabrication process was developed to produce sufficiently steep (>60 deg) step-edges such that junctions exhibited RSJ-like current-voltage characteristics. The mean I C R N product of a sample of twenty step-edge junctions was 130μV. Step-edge dc SQUIDs with inductances between 67pH and 114pH were fabricated. Generally the SQUIDs had an intrinsic white flux noise in the 10-30μΦ 0 /√Hz range, with the best device, a 70pH SQUID, exhibiting a white flux noise of 5μΦ 0 /√Hz. Different first-order SQUID gradiometer designs were fabricated from single layers of YBCO. Two single-layer gradiometer (SLG) designs were fabricated on 10x10mm 2 substrates. The best balance and lowest gradient sensitivity measured for these devices were 1/300 and 308fT/cm√Hz (at 1 kHz) respectively. The larger baseline and larger flux capture area of the pick-up loops in a large area SLG design, fabricated on 30x10mm 2 substrates, resulted in significant improvements in the balance and gradient field sensitivity with 1/1000 and 50fT/cm√Hz (at 1kHz) measured respectively. To reduce the uniform field effective area of SLOs and therefore reduce the direct pick-up of environmental field noise when operated unshielded, a novel gradiometric SQUID (G-SQUID) device was developed. Fabricated from a single layer of YBCO, the G-SQUIDs with inductances of 67pH, had small uniform field effective areas of approximately 2μm 2 - more than two orders of magnitude smaller than the uniform field effective areas of conventional narrow linewidth SQUIDs of similar inductance. Two designs of G-SQUID were fabricated on 10x10mm 2 substrates. Due to their small effective areas, when cooled unshielded these devices showed no increase in their white flux noise. The best balance achieved for a G-SQUID

  15. Front-end multiplexing—applied to SQUID multiplexing: Athena X-IFU and QUBIC experiments

    Science.gov (United States)

    Prele, D.

    2015-08-01

    As we have seen for digital camera market and a sensor resolution increasing to "megapixels", all the scientific and high-tech imagers (whatever the wave length - from radio to X-ray range) tends also to always increases the pixels number. So the constraints on front-end signals transmission increase too. An almost unavoidable solution to simplify integration of large arrays of pixels is front-end multiplexing. Moreover, "simple" and "efficient" techniques allow integration of read-out multiplexers in the focal plane itself. For instance, CCD (Charge Coupled Device) technology has boost number of pixels in digital camera. Indeed, this is exactly a planar technology which integrates both the sensors and a front-end multiplexed readout. In this context, front-end multiplexing techniques will be discussed for a better understanding of their advantages and their limits. Finally, the cases of astronomical instruments in the millimeter and in the X-ray ranges using SQUID (Superconducting QUantum Interference Device) will be described.

  16. Front-end multiplexing—applied to SQUID multiplexing: Athena X-IFU and QUBIC experiments

    International Nuclear Information System (INIS)

    Prele, D.

    2015-01-01

    As we have seen for digital camera market and a sensor resolution increasing to 'megapixels', all the scientific and high-tech imagers (whatever the wave length - from radio to X-ray range) tends also to always increases the pixels number. So the constraints on front-end signals transmission increase too. An almost unavoidable solution to simplify integration of large arrays of pixels is front-end multiplexing. Moreover, 'simple' and 'efficient' techniques allow integration of read-out multiplexers in the focal plane itself. For instance, CCD (Charge Coupled Device) technology has boost number of pixels in digital camera. Indeed, this is exactly a planar technology which integrates both the sensors and a front-end multiplexed readout. In this context, front-end multiplexing techniques will be discussed for a better understanding of their advantages and their limits. Finally, the cases of astronomical instruments in the millimeter and in the X-ray ranges using SQUID (Superconducting QUantum Interference Device) will be described

  17. Magnetic imaging of unconventional superconductors by scanning SQUID microscopy

    International Nuclear Information System (INIS)

    Hykel, D.

    2011-01-01

    We present the development of a scanning SQUID/AFM microscope and measurements performed on different samples. The microscope can take topographic and magnetic images simultaneously. The magnetic resolution is of the order of 10 -4 Φ 0 √Hz and the spatial resolution of the SQUIDs used in this thesis goes up to 600 nm. The scanning range is 70 μm * 85 μm. The temperature range accessible is between 200 mK and 10 K at the time of writing. Measurements on a thin rhenium film (80 nm) give an estimate of the minimal pinning force of a vortex of about 3.9 * 10 -16 N. Furthermore, the penetration depth λ on this sample was determined as a function of temperature. For T → 0, λ →79 nm. We have for the first time shown local measurements of the domain structure of the superconducting ferromagnet UCoGe and determined the average domain size in the virgin state (10 μm). By magnetic imaging we were capable of determining the magnetic field difference above opposite domains along the c-axis to be 45 G and 16 G along the b-axis. Due to these magnetic field measurements we were able to give an upper limit for the domain wall width (∼ 1μm) and domain reconstruction depth (100 nm). This is supported by simple calculations leading to a domain wall width of several angstroms. Thus UCoGe can be considered an ideal Ising ferromagnet. Different possible domain structures for an Ising ferromagnet have been discussed. The complicated domain structure found in the zero field cooled virgin state corresponds to up domains embedded in larger down domains and vice versa. We have shown evidence for coexistence of superconductivity and ferromagnetism. The weak Meissner effect can be explained by a spontaneous vortex state, put forward by other groups. Numerical simulations suggest that the strong magnetic background signal and the limited spatial and magnetic resolution of the used SQUID made it difficult to resolve the expected spontaneous vortex state. The relaxation of the

  18. Alignment of Outcome Instruments Used in Hand Therapy With the Occupational Therapy Practice Framework: Domain and Process and the International Classification of Functioning, Disability and Health: A Scoping Review.

    Science.gov (United States)

    Lesher, Danielle Ann-Marie; Mulcahey, M J; Hershey, Peter; Stanton, Donna Breger; Tiedgen, Andrea C

    We sought to identify outcome instruments used in rehabilitation of the hand and upper extremity; to determine their alignment with the constructs of the International Classification of Functioning, Disability and Health (ICF) and the Occupational Therapy Practice Framework: Domain and Process; and to report gaps in the constructs measured by outcome instruments as a basis for future research. We searched CINAHL, MEDLINE, OTseeker, and the Cochrane Central Register of Controlled Trials using scoping review methodology and evaluated outcome instruments for concordance with the ICF and the Framework. We identified 18 outcome instruments for analysis. The findings pertain to occupational therapists' focus on body functions, body structures, client factors, and activities of daily living; a gap in practice patterns in use of instruments; and overestimation of the degree to which instruments used are occupationally based. Occupational therapy practitioners should use outcome instruments that embody conceptual frameworks for classifying function and activity. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  19. [Validation of an instrument to measure food practices in Chilean families of school children aged 4-7 years].

    Science.gov (United States)

    Lera, Lydia; Salinas, Judith; Fretes, Gabriela; Vio, Fernando

    2013-11-01

    It is necessary to assess family food habits in school children to cope with infant obesity. Designing and validation of an instrument to measure food habits and food knowledge in Chilean preschool and school families based on dietary guidelines. A pilot study in 30 preschool and school-age parents was carried-out. A questionnaire to measure food habits and food knowledge in parents was elaborated by researchers considering an expert group opinion. This questionnaire was applied twice with a 15 days interval, evaluating temporal stability, internal consistency and inter-personal agreement. Afterwards, the questionnaire was applied to 59 parents calculating the internal consistency of the instrument. The questionnaire had 55 questions in 4 sections. The instrument had questions about food and nutrition information about the families. A good inter-personal agreement resulted for almost all the questions about food and nutrition information (0.5-1.0). The correlation between the first and second test (test-retest) was high (0.6-1.0), as well as the internal consistency (0.75). In the section about frequency consumption in parents and children food consumption at home and school there was a high internal consistency for the two observers (0.85-0.92 and 0.87-0.90). The instrument is valid and useful to be utilized in preschool and school families intervened with nutrition education, and this methodology can be replied in other studies. Copyright AULA MEDICA EDICIONES 2013. Published by AULA MEDICA. All rights reserved.

  20. Code of practice for in-core instrumentation for neutron fluence rate (flux) measurements in power reactors

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This standard applies to in-core (on-line) neutron detectors and instrumentation which is designed for safety, information or control purposes. It also applies to components in so far as these components are contained within the primary envelope of the reactor. The detector types usually used are dc ionization chambers and self-powered neutron detectors

  1. Multichannel DC SQUID sensor array for biomagnetic applications

    International Nuclear Information System (INIS)

    Hoenig, H.E.; Daalmans, G.M.; Bar, L.; Bommel, F.; Paulus, A.; Uhl, D.; Weisse, H.J.; Schneider, S.; Seifert, H.; Reichenberger, H.; Abraham-Fuchs, K.

    1991-01-01

    This paper reports on a biomagnetic multichannel system for medical diagnosis of brain and heart KRENIKON has been developed. 37 axial 2st order gradiometers - manufactured as flexible superconducting printed circuits - are arranged in a circular flat array of 19 cm diameter. Additionally, 3 orthogonal magnetometers are provided. The DC SQUIDs are fabricated in all-Nb technology, ten on a chip. The sensor system is operated in a shielded room with two layers of soft magnetic material and one layer of Al. The every day noise level is 10 fT/Hz 1/2 at frequencies above 10 Hz. Within 2 years of operation in a normal urban surrounding, useful clinical applications have been demonstrated (e.g. for epilepsy and heart arrhythmias)

  2. Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Woong; Kwon, Hyuk Chan; Kim, Ki Dam; Lee, Yong Ho; Kim, Jin Mok; Kim, In Seon; Lim, Hyun Kyoon; Park, Yong Ki [Biomagnetism Research, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kim, Doo Sang [Seoul Veterans Hospital, Seoul (Korea, Republic of); Lim, Seung Pyung [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2005-10-15

    We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was 10 fT/Hz(a) 1 Hz and 5 fT/Hz(a) 100 Hz. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  3. SQUID-detected magnetic resonance imaging in microtesla magnetic fields

    International Nuclear Information System (INIS)

    McDermott, Robert; Kelso, Nathan; Lee, SeungKyun; Moessle, Michael; Mueck, Michael; Myers, Whittier; Haken, Bernard ten; Seton, H.C.; Trabesinger, Andreas H.; Pines, Alex; Clarke, John

    2003-01-01

    We describe studies of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) of liquid samples at room temperature in microtesla magnetic fields. The nuclear spins are prepolarized in a strong transient field. The magnetic signals generated by the precessing spins, which range in frequency from tens of Hz to several kHz, are detected by a low-transition temperature dc SQUID (Superconducting QUantum Interference Device) coupled to an untuned, superconducting flux transformer configured as an axial gradiometer. The combination of prepolarization and frequency-independent detector sensitivity results in a high signal-to-noise ratio and high spectral resolution (∼1 Hz) even in grossly inhomogeneous magnetic fields. In the NMR experiments, the high spectral resolution enables us to detect the 10-Hz splitting of the spectrum of protons due to their scalar coupling to a 31P nucleus. Furthermore, the broadband detection scheme combined with a non-resonant field-reversal spin echo allows the simultaneous observation of signals from protons and 31P nuclei, even though their NMR resonance frequencies differ by a factor of 2.5. We extend our methodology to MRI in microtesla fields, where the high spectral resolution translates into high spatial resolution. We demonstrate two-dimensional images of a mineral oil phantom and slices of peppers, with a spatial resolution of about 1 mm. We also image an intact pepper using slice selection, again with 1-mm resolution. In further experiments we demonstrate T1-contrast imaging of a water phantom, some parts of which were doped with a paramagnetic salt to reduce the longitudinal relaxation time T1. Possible applications of this MRI technique include screening for tumors and integration with existing multichannel SQUID systems for brain imaging

  4. SQUID-Detected Magnetic Resonance Imaging in MicroteslaFields

    Energy Technology Data Exchange (ETDEWEB)

    Moessle, Michael; Hatridge, Michael; Clarke, John

    2006-08-14

    amplitude in MRI using laser polarized noble gases such as {sup 3}He or {sup 129}Xe (10-12). Hyperpolarized gases were used successfully to image the human lung in fields on the order of several mT (13-15). To overcome the sensitivity loss of Faraday detection at low frequencies, ultrasensitive magnetometers based on the Superconducting QUantum Interference Device (SQUID) (16) are used to detect NMR and MRI signals (17-24). Recently, SQUID-based MRI systems capable of acquiring in vivo images have appeared. For example, in the 10-mT system of Seton et al. (18) signals are coupled to a SQUID via a superconducting tuned circuit, while Clarke and coworkers (22, 25, 26) developed a system at 132 {micro}T with an untuned input circuit coupled to a SQUID. In a quite different approach, atomic magnetometers have been used recently to detect the magnetization (27) and NMR signal (28) of hyperpolarized gases. This technique could potentially be used for low-field MRI in the future. The goal of this review is to summarize the current state-of-the-art of MRI in microtesla fields detected with SQUIDs. The principles of SQUIDs and NMR are briefly reviewed. We show that very narrow NMR linewidths can be achieved in low magnetic fields that are quite inhomogeneous, with illustrative examples from spectroscopy. After describing our ultralow-field MRI system, we present a variety of images. We demonstrate that in microtesla fields the longitudinal relaxation T{sub 1} is much more material dependent than is the case in high fields; this results in a substantial improvement in 'T{sub 1}-weighted contrast imaging'. After outlining the first attempts to combine microtesla NMR with magnetoencephalography (MEG) (29), we conclude with a discussion of future directions.

  5. Imaging of current density distributions with a Nb weak-link scanning nano-SQUID microscope

    Science.gov (United States)

    Shibata, Yusuke; Nomura, Shintaro; Kashiwaya, Hiromi; Kashiwaya, Satoshi; Ishiguro, Ryosuke; Takayanagi, Hideaki

    2015-10-01

    Superconducting quantum interference devices (SQUIDs) are accepted as one of the highest magnetic field sensitive probes. There are increasing demands to image local magnetic fields to explore spin properties and current density distributions in a two-dimensional layer of semiconductors or superconductors. Nano-SQUIDs have recently attracting much interest for high spatial resolution measurements in nanometer-scale samples. Whereas weak-link Dayem Josephson junction nano-SQUIDs are suitable to miniaturization, hysteresis in current-voltage (I-V) characteristics that is often observed in Dayem Josephson junction is not desirable for a scanning microscope. Here we report on our development of a weak-link nano-SQUIDs scanning microscope with small hysteresis in I-V curve and on reconstructions of two-dimensional current density vector in two-dimensional electron gas from measured magnetic field.

  6. Technology for SQUID systems for the application in magnetically disturbed environment. Final report

    International Nuclear Information System (INIS)

    Schultze, V.; Fritzsch, L.; Thrum, F.; Stolz, R.; Chwala, A.

    1996-06-01

    International available SQUID systems, as used for example in biomagnetic research, obtain high sensitivities for magnetic fields or magnetic fieldgradients. However, these systems were optimised for operation in magnetically shielded rooms. Goal of this project was to develop SQUIDs suppressing the external noise and therefore are able to operate without external shielding in normal environments. As a consequence, the required Nb/AlO x /Nb technology has also been developed. The resulting planar SQUID gradiometers as produced at the IPHT, reached a suppression of homogeneous fields up to 5 x 10 4 for a magnetic field sensitivity c , project. SQUID gradiometers, produced using YBCO technology, were successfully operated in non shielded eddy current NDE measurements in the lab. (orig.) [de

  7. Growth of juvenile shrimp Metapenaeus monoceros fed with squid and mussel

    Digital Repository Service at National Institute of Oceanography (India)

    Achuthankutty, C.T.; Nair, S.R.S.; Krishnakumari, L.

    Small juveniles of both sexes and females of large juveniles of Metapenaeus monoceros attained faster growth with squid diet. Males of large juveniles registered better growth with mussel diet. No significant difference was observed in moult weights...

  8. High-T /SUB c/ Superconducting integrated circuit: a dc SQUID with input coil

    International Nuclear Information System (INIS)

    Di Iorio, M.S.; Beasley, M.R.

    1985-01-01

    We have fabricated a high transition temperature superconducting integrated circuit consisting of a dc SQUID and an input coupling coil. The purpose is to ascertain the generic problems associated with constructing a high-T /SUB c/ circuit as well as to fabricate a high performance dc SQUID. The superconductor used for both the SQUID and the input coil is Nb 3 Sn which must be deposited at 800 0 C. Importantly, the insulator separating SQUID and input coil maintains its integrity at this elevated temperature. A hole in the insulator permits contact to the innermost winding of the coil. This contact has been achieved without significant degradation of the superconductivity. Consequently, the device operates over a wide temperature range, from below 4.2 K to near T /SUB c/

  9. Performance of a novel SQUID-based superconducting imaging-surface magnetoencephalography system

    Science.gov (United States)

    Kraus, R. H.; Volegov, P.; Maharajh, K.; Espy, M. A.; Matlashov, A. N.; Flynn, E. R.

    2002-03-01

    Performance for a recently completed whole-head magnetoencephalography system using a superconducting imaging surface (SIS) surrounding an array of 150 SQUID magnetometers is reported. The helmet-like SIS is hemispherical in shape with a brim. Conceptually, the SIS images nearby sources onto the SQUIDs while shielding sensors from distant “noise” sources. A finite element method (FEM) description using the as-built geometry was developed to describe the SIS effect on source fields by imposing B⊥( surface)=0 . Sensors consist of 8×8 mm 2 SQUID magnetometers with 0.84 nT/ Φ0 sensitivity and positions and orientations was found. Good agreement was found between modeled and measured shielding of the SQUIDs from sources external to the array showing significant frequency-independent shielding. Phantom localization precision was better than 0.5 mm at all locations with a mean of better than 0.3 mm.

  10. Development of a Flow-Through SQUID System for Non-Destructive Evaluation of MRI Wire

    National Research Council Canada - National Science Library

    Wellstood, Frederick C

    2007-01-01

    ...) superconducting quantum interference device (SQUID) system. The ability to detect small defects in km-long sections of NbTi magnet wire could improve the production yield of high-field magnets for power and medical applications...

  11. Analysis of the ac SQUID with low inductance and low critical current

    DEFF Research Database (Denmark)

    Sørensen, O. H.

    1976-01-01

    The properties of the ac SQUID magnetometer has been analyzed. The results are valid in the low-inductance low-critical-current regime, where the Lri0 producted is belowthe value at which the relation between the enclosed and externally applied magnetic dc flux becomes reentrant. The effects...... of the screening current circulating in the SQUID ring as well as of the SQUID-ring time constant, tau-Lr/R9 are taken into account. Here LR IS THE SQUID-ring inductance, and R is the shunt resistance in the shunted junction model assumed to describe the weak link. It is shown that for finite values of omegatau...... constriuctively with the result that the optimal response occurs at a definite and finite value of omegatau. If omegatau is increased beyond this optimal value the weak link behavior is dominated by the Ohmic current channel implying that only if the shunt conductance contains a term depending...

  12. 76 FR 66260 - Fisheries of the Northeastern United States; Atlantic Mackerel, Squid, and Butterfish Fisheries...

    Science.gov (United States)

    2011-10-26

    ...) of scup, 184,280 lb (83,588 kg) of black sea bass, and 200,000 lb (90,718 kg) of bluefish. Project... summer flounder, scup, black sea bass, longfin squid, butterfish, and Atlantic bluefish, and assessment...

  13. The Classroom Observation Protocol for Undergraduate STEM (COPUS): A New Instrument to Characterize University STEM Classroom Practices

    Science.gov (United States)

    Smith, Michelle K.; Jones, Francis H. M.; Gilbert, Sarah L.; Wieman, Carl E.

    2013-01-01

    Instructors and the teaching practices they employ play a critical role in improving student learning in college science, technology, engineering, and mathematics (STEM) courses. Consequently, there is increasing interest in collecting information on the range and frequency of teaching practices at department-wide and institution-wide scales. To…

  14. Profile of South African Secondary-School Teachers' Teaching Quality: Evaluation of Teaching Practices Using an Observation Instrument

    Science.gov (United States)

    de Jager, Thelma; Coetzee, Mattheus Jacobus; Maulana, Ridwan; Helms-Lorenz, Michelle; van de Grift, Wim

    2017-01-01

    The need for quality teaching is reflected in the poor performance of students in international tests. Teachers' practices and contextual factors could contribute to substandard quality of teaching in South Africa. Several studies indicate that successful learning is largely dependent on the teachers' practices in class. The focus of the present…

  15. The bases for the development of high-temperature integrated SQUID-systems

    International Nuclear Information System (INIS)

    Polushkin, V.N.

    1992-01-01

    The current state of high-T c superconducting thin-film Josephson junctions and SQUIDs developing is reviewed. The prospects of application of new devices in supersensitive measurement apparatus are analyzed. It is shown that high T c SQUIDs are able seriously to influence further development of information and measurement engineering as on their base the series of microelectronic elements and devices of new generation can be built. 55 refs.; 7 figs.; 2 tabs

  16. The bases for the development of high-temperature integrated squid-systems

    International Nuclear Information System (INIS)

    Polushkin, V.N.

    1992-01-01

    The current state of high-Tc superconducting thinfilm Josepson junctions and SQUIDs developing is reviewed. The prospects of application of new devices in supersensitive measurement apparatus are analyzed. It is shown that high T c SQUIDs are able seriously to influence further development of information and measurement engineering as on their base the series of microelectronic elements and devices of new generation can be built. 84 refs.; 16 figs.; 3 tabs

  17. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  18. [Quality of advanced practice nurse counseling in home care settings (APN-BQ): psychometric testing of the instrument].

    Science.gov (United States)

    Petry, Heidi; Suter-Riederer, Susanne; Kerker-Specker, Carmen; Imhof, Lorenz

    2014-12-01

    Patient centred and individually-tailored counselling of older people with a chronic condition who live at home is a useful intervention to support their independence. The paper presents the development and psychometric testing of the APN-BQ Instrument, to measure patient-centeredness. To measure the quality of an in-home counselling intervention, a 23-item questionnaire was developed and tested with 206 people 80 years and older. Principal component analysis with Varimax Rotation was conducted (n = 206). Analysis revealed a four factor (fs = 0.91) model scoring in 19 items. All factors loaded > 0.45. Cronbach's alpha was 0.86. The utility and acceptance of the instrument was confirmed by the high response rate (100 %) and the fact that participants answered 98.8 % of all questions. The APN-BQ has shown to be a reliable Instrument with good content and construct validity. It is a tool for APNs to measure structure, process, and outcome quality of a patient-centred and individually-tailored counselling program, including the degree of patient participation, and patient empowerment.

  19. Identification of four squid species by quantitative real-time polymerase chain reaction.

    Science.gov (United States)

    Ye, Jian; Feng, Junli; Liu, Shasha; Zhang, Yanping; Jiang, Xiaona; Dai, Zhiyuan

    2016-02-01

    Squids are distributed worldwide, including many species of commercial importance, and they are often made into varieties of flavor foods. The rapid identification methods for squid species especially their processed products, however, have not been well developed. In this study, quantitative real-time PCR (qPCR) systems based on specific primers and TaqMan probes have been established for rapid and accurate identification of four common squid species (Ommastrephes bartramii, Dosidicus gigas, Illex argentinus, Todarodes pacificus) in Chinese domestic market. After analyzing mitochondrial genes reported in GenBank, the mitochondrial cytochrome b (Cytb) gene was selected for O. bartramii detection, cytochrome c oxidase subunit I (COI) gene for D. gigas and T. Pacificus detection, ATPase subunit 6 (ATPase 6) gene for I. Argentinus detection, and 12S ribosomal RNA (12S rDNA) gene for designing Ommastrephidae-specific primers and probe. As a result, all the TaqMan systems are of good performance, and efficiency of each reaction was calculated by making standard curves. This method could detect target species either in single or mixed squid specimen, and it was applied to identify 12 squid processed products successfully. Thus, it would play an important role in fulfilling labeling regulations and squid fishery control. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Squid-derived chitin oligosaccharides are a chemotactic signal during colonization by Vibrio fischeri.

    Science.gov (United States)

    Mandel, Mark J; Schaefer, Amy L; Brennan, Caitlin A; Heath-Heckman, Elizabeth A C; Deloney-Marino, Cindy R; McFall-Ngai, Margaret J; Ruby, Edward G

    2012-07-01

    Chitin, a polymer of N-acetylglucosamine (GlcNAc), is noted as the second most abundant biopolymer in nature. Chitin serves many functions for marine bacteria in the family Vibrionaceae ("vibrios"), in some instances providing a physical attachment site, inducing natural genetic competence, and serving as an attractant for chemotaxis. The marine luminous bacterium Vibrio fischeri is the specific symbiont in the light-emitting organ of the Hawaiian bobtail squid, Euprymna scolopes. The bacterium provides the squid with luminescence that the animal uses in an antipredatory defense, while the squid supports the symbiont's nutritional requirements. V. fischeri cells are harvested from seawater during each host generation, and V. fischeri is the only species that can complete this process in nature. Furthermore, chitin is located in squid hemocytes and plays a nutritional role in the symbiosis. We demonstrate here that chitin oligosaccharides produced by the squid host serve as a chemotactic signal for colonizing bacteria. V. fischeri uses the gradient of host chitin to enter the squid light organ duct and colonize the animal. We provide evidence that chitin serves a novel function in an animal-bacterial mutualism, as an animal-produced bacterium-attracting synomone.

  1. Exploring the psychometric properties of the humanistic teaching practices effectiveness questionnaire, an instrument to measure the humanistic qualities of medical teachers.

    Science.gov (United States)

    Logio, Lia Suzanne; Monahan, Patrick; Stump, Timothy E; Branch, William T; Frankel, Richard M; Inui, Thomas S

    2011-08-01

    To describe the development and psychometric properties of the Humanistic Teaching Practices Effectiveness Questionnaire (HTPE), an instrument that measures the humanistic skills of attending physicians within an academic health center (AHC) department of medicine. From August 2005 through March 2007, the authors distributed the HTPE, along with other standard faculty evaluations, to internal medicine and medicine/pediatrics residents at a single midwestern AHC (the Indiana University School of Medicine), in an effort to assess the instrument's validity and reliability. The data set included 886 completed HTPE questionnaires, representing 73% of the 1,212 administered. Exploratory factor analysis demonstrated a single major factor with high internal consistency reliability. The correlation between the HTPE and routine teaching evaluation tools was low. Interrater reliability was only fair (0.17). Total HTPE scores were not significantly different between female and male attending physicians. The 10-item HTPE provides reliable and valid information on the humanistic teaching practices of internal medicine faculty at a single AHC. The ability to reliably measure these practices provides a framework for understanding and promoting the skills to effectively demonstrate humanism at the bedside and in the clinic. The low correlation between the HTPE and other faculty evaluations suggests that the former measures a unique domain in attending physicians' performance. The HTPE items cluster together as a single construct allowing educators to choose fewer items without compromising reliability; however, moderate interrater reliability indicates that multiple raters are required to produce reliable scores.

  2. The Classroom Observation Protocol for Undergraduate STEM (COPUS): A New Instrument to Characterize University STEM Classroom Practices

    OpenAIRE

    Smith, Michelle K.; Jones, Francis H. M.; Gilbert, Sarah L.; Wieman, Carl E.

    2013-01-01

    Instructors and the teaching practices they employ play a critical role in improving student learning in college science, technology, engineering, and mathematics (STEM) courses. Consequently, there is increasing interest in collecting information on the range and frequency of teaching practices at department-wide and institution-wide scales. To help facilitate this process, we present a new classroom observation protocol known as the Classroom Observation Protocol for Undergraduate STEM or C...

  3. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  4. Influence of inductance induced noise in an YBa2Cu3O7 dc-SQUID at high operation temperatures

    DEFF Research Database (Denmark)

    Nilsson, P. Å.; Claeson, T.; Hansen, J. B.

    1994-01-01

    The voltage modulation depth of a high T(c) dc-SQUID was measured at temperatures close to T(c) and compared to a model by Enpuku et al. where the flux noise from the SQUID inductance is taken into account. The device was an YBa2Cu3O7 dc-SQUID made on a bicrystal substrate of SrTiO3. The design w...

  5. Apparatus and method for detecting a magnetic anomaly contiguous to remote location by SQUID gradiometer and magnetometer systems

    Science.gov (United States)

    Overton, W.C. Jr.; Steyert, W.A. Jr.

    1981-05-22

    A superconducting quantum interference device (SQUID) magnetic detection apparatus detects magnetic fields, signals, and anomalies at remote locations. Two remotely rotatable SQUID gradiometers may be housed in a cryogenic environment to search for and locate unambiguously magnetic anomalies. The SQUID magnetic detection apparatus can be used to determine the azimuth of a hydrofracture by first flooding the hydrofracture with a ferrofluid to create an artificial magnetic anomaly therein.

  6. Emancipatory practices of nurses in primary health care: the home visit as an instrument of health needs assessment

    Directory of Open Access Journals (Sweden)

    Celia Maria Sivalli Campos

    Full Text Available Objective Identify nurses’ emancipatory practices in primary care, to contribute to the improvement of health care. Method A case study type social research of qualitative nature, in which nurses of a primary health care service unit in São Paulo were interviewed. Results The home visit was identified as a nursing practice possible to be expanded in order to identify social determinants of health, triggering emancipatory practices in the service. This expansion occurred because the design of health care labour intended by the service team changed its focus from the traditional object of health services, the disease. Conclusion First, it is advocated that social policies lead projects with the purpose of improving health needs. On the other hand, the daily labour needs to provide opportunities for reflection and discussion of healthcare projects, leading workers to propose labour-processes targeted to both the social determinants of health and people’s illness.

  7. Emancipatory practices of nurses in primary health care: the home visit as an instrument of health needs assessment

    Directory of Open Access Journals (Sweden)

    Celia Maria Sivalli Campos

    2014-08-01

    Full Text Available Objective Identify nurses’ emancipatory practices in primary care, to contribute to the improvement of health care. Method A case study type social research of qualitative nature, in which nurses of a primary health care service unit in São Paulo were interviewed. Results The home visit was identified as a nursing practice possible to be expanded in order to identify social determinants of health, triggering emancipatory practices in the service. This expansion occurred because the design of health care labour intended by the service team changed its focus from the traditional object of health services, the disease. Conclusion First, it is advocated that social policies lead projects with the purpose of improving health needs. On the other hand, the daily labour needs to provide opportunities for reflection and discussion of healthcare projects, leading workers to propose labour-processes targeted to both the social determinants of health and people’s illness.

  8. Validity and reliability of instruments aimed at measuring Evidence-Based Practice in Physical Therapy: a systematic review of the literature.

    Science.gov (United States)

    Fernández-Domínguez, Juan Carlos; Sesé-Abad, Albert; Morales-Asencio, Jose Miguel; Oliva-Pascual-Vaca, Angel; Salinas-Bueno, Iosune; de Pedro-Gómez, Joan Ernest

    2014-12-01

    Our goal is to compile and analyse the characteristics - especially validity and reliability - of all the existing international tools that have been used to measure evidence-based clinical practice in physiotherapy. A systematic review conducted with data from exclusively quantitative-type studies synthesized in narrative format. An in-depth search of the literature was conducted in two phases: initial, structured, electronic search of databases and also journals with summarized evidence; followed by a residual-directed search in the bibliographical references of the main articles found in the primary search procedure. The studies included were assigned to members of the research team who acted as peer reviewers. Relevant information was extracted from each of the selected articles using a template that included the general characteristics of the instrument as well as an analysis of the quality of the validation processes carried out, by following the criteria of Terwee. Twenty-four instruments were found to comply with the review screening criteria; however, in all cases, they were found to be limited as regards the 'constructs' included. Besides, they can all be seen to be lacking as regards comprehensiveness associated to the validation process of the psychometric tests used. It seems that what constitutes a rigorously developed assessment instrument for EBP in physical therapy continues to be a challenge. © 2014 John Wiley & Sons, Ltd.

  9. Development and validation of an international appraisal instrument for assessing the quality of clinical practice guidelines: the AGREE project.

    NARCIS (Netherlands)

    Cluzeau, F.A.; Burgers, J.S.; Brouwers, M.M.; Grol, R.P.T.M.; et al.,

    2003-01-01

    BACKGROUND: International interest in clinical practice guidelines has never been greater but many published guidelines do not meet the basic quality requirements. There have been renewed calls for validated criteria to assess the quality of guidelines. OBJECTIVE: To develop and validate an

  10. Teachers' Self-Efficacy and Knowledge of Healthy Nutrition and Physical Activity Practices for Preschoolers: Instrument Development and Validation

    Science.gov (United States)

    Derscheid, Linda E.; Kim, So-Yeun; Zittel, Lauriece L.; Umoren, Josephine; Henry, Beverly W.

    2014-01-01

    Childhood obesity remains a problem in the United States. Preschool teachers can help to attenuate it but need to have the confidence or self-efficacy to provide healthy practices. Therefore, the purpose of this study was to (a) develop and validate a preschool teacher self-efficacy tool to examine teachers' confidence in addressing the nutrition…

  11. Are the physical activity parenting practices reported by U.S. and Canadian parents captured in currently published instruments?

    Science.gov (United States)

    The purpose of this study was to compare the physical activity parenting practices (PAPPs) parents report using with the PAPPs incorporated in the published literature. PAPPs in the literature were identified by reviewing the content of 74 published PAPPs measures obtained from current systematic re...

  12. Optical parameters of the tunable Bragg reflectors in squid.

    Science.gov (United States)

    Ghoshal, Amitabh; Demartini, Daniel G; Eck, Elizabeth; Morse, Daniel E

    2013-08-06

    Cephalopods (e.g. octopus, squid and cuttlefish) dynamically tune the colour and brightness of their skin for camouflage and communication using specialized skin cells called iridocytes. We use high-resolution microspectrophotometry to investigate individual tunable Bragg structures (consisting of alternating reflectin protein-containing, high-refractive index lamellae and low-refractive index inter-lamellar spaces) in live and chemically fixed iridocytes of the California market squid, Doryteuthis opalescens. This subcellular, single-stack microspectrophotometry allows for spectral normalization, permitting use of a transfer-matrix model of Bragg reflectance to calculate all the parameters of the Bragg stack-the refractive indices, dimensions and numbers of the lamellae and inter-lamellar spaces. Results of the fitting analyses show that eight or nine pairs of low- and high-index layers typically contribute to the observed reflectivity in live cells, whereas six or seven pairs of low- and high-index layers typically contribute to the reflectivity in chemically fixed cells. The reflectin-containing, high-index lamellae of live cells have a refractive index proportional to the peak reflectivity, with an average of 1.405 ± 0.012 and a maximum around 1.44, while the reflectin-containing lamellae in fixed tissue have a refractive index of 1.413 ± 0.015 suggesting a slight increase of refractive index in the process of fixation. As expected, incremental changes in refractive index contribute to the greatest incremental changes in reflectivity for those Bragg stacks with the most layers. The excursions in dimensions required to tune the measured reflected wavelength from 675 (red) to 425 nm (blue) are a decrease from ca 150 to 80 nm for the high-index lamellae and from ca 120 to 50 nm for the low-index inter-lamellar spaces. Fixation-induced dimensional changes also are quantified, leading us to suggest that further microspectrophotometric analyses of this iridocyte

  13. Acquisition of sorption isotherms for modified woods by the use of dynamic vapour sorption instrumentation. Principles and Practice

    DEFF Research Database (Denmark)

    Engelund, Emil Tang; Klamer, Morten; Venås, Thomas Mark

    2010-01-01

    The complex wood-water relationship has been the topic of numerous studies. Sorption isotherms – in particular – have been derived for hundreds of wood species, their sap- and heartwood sections as well as for decayed, engineered and modified wood materials. However, the traditional methods...... for obtaining sorption isotherms are very time consuming. With new dynamic vapour sorption (DVS) instrumentation, the acquisition of data for constructing sorption isotherms is suddenly dramatically lowered. Where the traditional methods often required months, data can now be obtained in a matter of days...... depending on the number of data points required. The fast data acquisition makes DVS a useful tool in studying the sorption properties of wood, and especially in studying the effect of different modification treatments on these properties. This study includes an investigation of the sorption properties...

  14. Retrieval practice after multiple context changes, but not long retention intervals, reduces the impact of a final context change on instrumental behavior.

    Science.gov (United States)

    Trask, Sydney; Bouton, Mark E

    2018-06-01

    Recent evidence from this laboratory suggests that a context switch after operant learning consistently results in a decrement in responding. One way to reduce this decrement is to train the response in multiple contexts. One interpretation of this result, rooted in stimulus sampling theory, is that conditioning of a greater number of common stimulus elements arising from more contexts causes better generalization to new contexts. An alternative explanation is that each change of context causes more effortful retrieval, and practice involving effortful retrieval results in learning that is better able to transfer to new situations. The current experiments were designed to differentiate between these two explanations for the first time in an animal learning and memory task. Experiment 1 demonstrated that the detrimental impact of a context change on an instrumental nose-poking response can be reduced by training the response in multiple contexts. Experiment 2 then found that a training procedure which inserted extended retention intervals between successive training sessions did not reduce the detrimental impact of a final context change. This occurred even though the inserted retention intervals had a detrimental impact on responding (and, thus, presumably retrieval) similar to the effect that context switches had in Experiment 1. Together, the results suggest that effortful retrieval practice may not be sufficient to reduce the negative impact of a context change on instrumental behavior. A common elements explanation which supposes that physical and temporal contextual cues do not overlap may account for the findings more readily.

  15. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  16. An Assessment of the Effectiveness of Air Force Risk Management Practices in Program Acquisition Using Survey Instrument Analysis

    Science.gov (United States)

    2015-06-18

    Engineering Effectiveness Survey. CMU/SEI-2012-SR-009. Carnegie Mellon University. November 2012. Field, Andy. Discovering Statistics Using SPSS , 3rd...enough into the survey to begin answering questions on risk practices. All of the data statistical analysis will be performed using SPSS . Prior to...probabilistically using distributions for likelihood and impact. Statistical methods like Monte Carlo can more comprehensively evaluate the cost and

  17. Development of improved superconductive axial gradiometers for biomagnetic SQUID applications

    Science.gov (United States)

    Budnyk, M. M.; Minov, Yu. D.; Lyakhno, V. Yu.; Desnenko, V. A.; Linnik, A. S.; Shopen, O. B.

    2018-03-01

    SQUID magnetometers for biomagnetic measurements are equipped with superconductive gradiometers which are required to provide a high signal-to-noise ratio at low frequencies, sufficient mechanical strength and sustained performance under repeated thermal cycles, as well as a low level of intrinsic magnetic noise. This paper describes the design of a gradiometer made with a carbon-fiber reinforced composite material for magnetic cardiography measurements. The thermal coefficient of linear expansion (TCLE) of the carbon fiber composite can be precisely adjusted to match that of the superconducting detector coil wire. This is achieved thanks to the difference in the TCLE of carbon fibers in the longitudinal and transverse directions and is realized by varying the laying directions of the fiber in the composite. The data of magnetic susceptibility measurements on carbon fiber composite are reported, showing the magnetic susceptibility about six times smaller than that of graphite. The presented gradiometer design provides a high degree of balancing and is patented along side other specific techniques.

  18. An interchangeable scanning Hall probe/scanning SQUID microscope

    International Nuclear Information System (INIS)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K

  19. Development of Contaminant Detection System using HTS SQUIDs

    International Nuclear Information System (INIS)

    Ohtani, T.; Tanaka, S.; Narita, Y.; Ariyoshi, S.; Suzuki, S.

    2015-01-01

    In terms of food safety, mixture of contaminants in food is a serious problem for not only consumers but also manufacturers. In general, the target size of the metallic contaminant to be removed is 0.5 mm. However, it is a difficult task for manufacturers to achieve this target, because of lower system sensitivity. Therefore, we developed a food contaminant detection system based on high-Tc RF superconducting quantum interference devices (SQUIDs), which are highly sensitive magnetic sensors. This study aims to improve the signal to noise ratio (SNR) of the system and detect a 0.5 mm diameter steel ball. Using a real time digital signal processing technique along with analog band-pass filters, we improved the SNR of the system. Owing to the improved SNR, a steel ball with a diameter as small as 0.3 mm, with stand-off distance of 117 mm was successfully detected. These results suggest that the proposed system is a promising candidate for the detection of metallic contaminants in food products

  20. An interchangeable scanning Hall probe/scanning SQUID microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Chen, Tse-Jun; Wang, M. J. [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan (China); Ling, D. C. [Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan (China); Chi, C. C.; Chen, Jeng-Chung [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  1. Dynamic Characteristics of S-band DC SQUID Amplifier

    DEFF Research Database (Denmark)

    Prokopenko, G. V.; Shitov, S. V.; Koshelets, I. L. L. V. P.

    2003-01-01

    A low-noise rf amplifier based on a de SQUID (SQA) has been tested in the frequency range 3.0-4.6 GHz in the open-loop configuration. The following parameters have been measured for the single-stage balanced type SQA at 4.0 GHz: gain (12 +/- 1) dB, 3 dB bandwidth of 500 MHz and noise temperature (1.......0 +/- 0.25) K. For the nonbalanced type SQA at 4.0 GHz gain was (15 +/-1) dB, 3 dB bandwidth 200 MHz and noise temperature (0.5 +/- 0.25) K. The improved performance is obtained due to the increased characteristic voltage (approximate to 420 muV) of the small-area (down to 0.7-0.9 mum(2)) high-quality Nb......-AlOx-Nb SIS junctions. The saturation power (normalized to 1 GHz) referred to the input at 1 dB gain compression is estimated as approximate to55 K*GHz at a bias voltage of 60 muV. The reasons for saturation of the SQA are discussed....

  2. Sperm from sneaker male squids exhibit chemotactic swarming to CO₂.

    Science.gov (United States)

    Hirohashi, Noritaka; Alvarez, Luis; Shiba, Kogiku; Fujiwara, Eiji; Iwata, Yoko; Mohri, Tatsuma; Inaba, Kazuo; Chiba, Kazuyoshi; Ochi, Hiroe; Supuran, Claudiu T; Kotzur, Nico; Kakiuchi, Yasutaka; Kaupp, U Benjamin; Baba, Shoji A

    2013-05-06

    Behavioral traits of sperm are adapted to the reproductive strategy that each species employs. In polyandrous species, spermatozoa often form motile clusters, which might be advantageous for competing with sperm from other males. Despite this presumed advantage for reproductive success, little is known about how sperm form such functional assemblies. Previously, we reported that males of the coastal squid Loligo bleekeri produce two morphologically different euspermatozoa that are linked to distinctly different mating behaviors. Consort and sneaker males use two distinct insemination sites, one inside and one outside the female's body, respectively. Here, we show that sperm release a self-attracting molecule that causes only sneaker sperm to swarm. We identified CO2 as the sperm chemoattractant and membrane-bound flagellar carbonic anhydrase as its sensor. Downstream signaling results from the generation of extracellular H(+), intracellular acidosis, and recovery from acidosis. These signaling events elicit Ca(2+)-dependent turning behavior, resulting in chemotactic swarming. These results illuminate the bifurcating evolution of sperm underlying the distinct fertilization strategies of this species. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. EFFECT OF DETERGENT ON ELECTRICAL PROPERTIES OF SQUID AXON MEMBRANE.

    Science.gov (United States)

    KISHIMOTO, U; ADELMAN, W J

    1964-05-01

    The effects of detergents on squid giant axon action and resting potentials as well as membrane conductances in the voltage clamp have been studied. Anionic detergents (sodium lauryl sulfate, 0.1 to 1.0 mM; dimethyl benzene sulfonate, 1 to 20 mM, pH 7.6) cause a temporary increase and a later decrease of action potential height and the value of the resting potential. Cationic detergent (cetyl trimethyl ammonium chloride, 6 x 10(-5)M or more, pH 7.6) generally brings about immediate and irreversible decreases in the action and resting potentials. Non-ionic detergent (tween 80, 0.1 M, pH 7.6) causes a slight reversible reduction of action potential height without affecting the value of the resting potential. Both anionic and cationic detergents generally decrease the sodium and potassium conductances irreversibly. The effect of non-ionic detergent is to decrease the sodium conductance reversibly, leaving the potassium conductance almost unchanged.

  4. Identifying Pelagic Habitat Hotspots of Neon Flying Squid in the Temperate Waters of the Central North Pacific.

    Science.gov (United States)

    Alabia, Irene D; Saitoh, Sei-Ichi; Mugo, Robinson; Igarashi, Hiromichi; Ishikawa, Yoichi; Usui, Norihisa; Kamachi, Masafumi; Awaji, Toshiyuki; Seito, Masaki

    2015-01-01

    We identified the pelagic habitat hotspots of the neon flying squid (Ommastrephes bartramii) in the central North Pacific from May to July and characterized the spatial patterns of squid aggregations in relation to oceanographic features such as mesoscale oceanic eddies and the Transition Zone Chlorophyll-a Front (TZCF). The data used for the habitat model construction and analyses were squid fishery information, remotely-sensed and numerical model-derived environmental data from May to July 1999-2010. Squid habitat hotspots were deduced from the monthly Maximum Entropy (MaxEnt) models and were identified as regions of persistent high suitable habitat across the 12-year period. The distribution of predicted squid habitat hotspots in central North Pacific revealed interesting spatial and temporal patterns likely linked with the presence and dynamics of oceanographic features in squid's putative foraging grounds from late spring to summer. From May to June, the inferred patches of squid habitat hotspots developed within the Kuroshio-Oyashio transition zone (KOTZ; 37-40°N) and further expanded north towards the subarctic frontal zone (SAFZ; 40-44°N) in July. The squid habitat hotspots within the KOTZ and areas west of the dateline (160°W-180°) were likely influenced and associated with the highly dynamic and transient oceanic eddies and could possibly account for lower squid suitable habitat persistence obtained from these regions. However, predicted squid habitat hotspots located in regions east of the dateline (180°-160°W) from June to July, showed predominantly higher squid habitat persistence presumably due to their proximity to the mean position of the seasonally-shifting TZCF and consequent utilization of the highly productive waters of the SAFZ.

  5. Opportunistic acoustic recordings of (potential) orangeback flying squid Sthenoteuthis pteropus in the Central Eastern Atlantic

    Science.gov (United States)

    Peña, Marian; Villanueva, Roger; Escánez, Alejandro; Ariza, Alejandro

    2018-03-01

    Squids are fast swimmers that are difficult to catch by nets and to record with echosounders in the open ocean. A rare detection of orangeback flying squid Sthenoteuthis pteropus in the Central Eastern Atlantic Ocean off the coast of Senegal was accomplished during the MAFIA oceanographic survey carried out between Brazil and the Canary Islands in April 2015. Although net sampling did not yield any subadult or adult individuals, dozens were visually detected from the vessel jumping out of the water at night and displaying their characteristic dorsal photophore patch. A few squids were caught with fishing lines and identified at the species level. The acoustic echograms revealed distinctive previously unobserved acoustic echotraces that seemed to be caused by those squids, which were the only new species detected at that station (over a bottom depth ranging from 4010 to 5215 m, between 10° 45‧ N 22° 41‧ W and 10° 53‧ N 22° 40‧ W). The acoustic response and swimming behaviour shown by those echotraces reinforced this hypothesis. The (potentially) squid recordings dove rapidly (0.19 m/s to 0.48 m/s) from around 10 m below the mesopelagic fish layer, which had migrated to the subsurface at night (35 m depth), to depths of 70-95 m, and swam upward, apparently attacking fish from below. The morning squid migration to deeper waters (250-300 m) was also recorded acoustically. Downward movements of squid swimming at speeds of 0.22 m/s were calculated from the echogram, while the mesopelagic migrating fish swam at 0.27 m/s reaching 250 m depth. Sv120 - Sv38 averaged 2.7 ± 3.2 dB for the squid echotraces while the mesopelagic layer showed values of -8.8 ± 0.9 dB. These ranges agreed with values in the literature and from theoretical models. This study provides more insight into the migrating behaviour of oceanic squids, a species group that is poorly represented in the acoustic literature due to challenges in studying them.

  6. Overview of improvements in work practices and instrumentation for CANDU primary heat transport feeders in-service inspections

    Energy Technology Data Exchange (ETDEWEB)

    Marcotte, O., E-mail: olivier@nucleom.ca [Nucleom Inc., Quebec, Quebec (Canada); Rousseau, G., E-mail: rousseau.gilles.a@hydro.qc.ca [Hydro Quebec, Becancour, Quebec (Canada); Rochefort, E., E-mail: erochfort@zetec.com [Zetec Canada, Quebec, Quebec (Canada)

    2013-01-15

    The Canadian nuclear industry has developed many advanced non-destructive inspection techniques to be applied safely in hazardous environments in recent years. Automated systems, manual tooling and specialized software modules have been designed since early 2000s to provide complete and very efficient fitness for service inspection of primary heat transport system carbon steel feeder pipes. These techniques deal with complex geometries, difficult access and, radioactive environment. Complementary NDE techniques, namely Ultrasounds, eddy current, phased-array UT and automated scanners are used. This presentation describes the improvements in inspection practices and the advanced data analysis features. (author)

  7. Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukade, Y. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp; Yotsugi, K.; Tanaka, S. [Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2008-09-15

    A robot-arm-based mobile HTS-SQUID NDE system was developed for inspection of advanced structures such as hydrogen fuel cell tanks. In order to realize stable operation of HTS-SQUID exposed in Earth's field and robot arm's noise without flux trapping, flux jumping and unlocking during motion, a new active magnetic shielding (AMS) technique using fluxgate was introduced. The high sensitive fluxgate, which could measure magnetic field of up to several 10 {mu}T, was mounted near an HTS-SQUID gradiometer on the robot arm to measure the ambient noise and feed back its output to a compensation coil, which surrounded both SQUID and fluxgate to cancel the ambient noise around them. The AMS technique successfully enabled the HTS-SQUID gradiometer to be moved at 10 mm/s by the robot arm in unshielded environment without flux trapping, jumping and unlocking. Detection of hidden slots in multi-layer composite-metal structures imitating the fuel cell tank was demonstrated.

  8. Vestigial phragmocone in the gladius points to a deepwater origin of squid (Mollusca: Cephalopoda)

    Science.gov (United States)

    Arkhipkin, Alexander I.; Bizikov, Vyacheslav A.; Fuchs, Dirk

    2012-03-01

    The microstructure of the gladius cone was investigated in six species of nektonic squid: shallow-water Loligo gahi (Loliginidae), pelagic eurybathic Illex argentinus, Todarodes pacificus, Dosidicus gigas (Ommastrephidae), and deepwater Onykia ingens (Onychoteuthidae) and Gonatus antarcticus (Gonatidae) using state-of-the-art microscopy. Apart from L. gahi, all other species had septa-like layers in the gladius cone, which for the first time were investigated in detail and compared with those in extinct Cretaceous belemnites Hibolithes sp. and Pachyteuthis sp., and spirulid Cyrtobelus sp. It was found that the organic layers of the gladius cone in recent squid can be homologized with the organic components of the shell in fossil phragmocone-bearing coleoids. The septa-like layers in modern gladius cones therefore represent a vestigial phragmocone composed of organic septal rudiments of the ancestral phragmocone that has lost the siphuncle and gas-filled chambers. The well-developed rostrum in onychoteuthids and small rostrum of the gladius in ommastrephids and gonatids can be seen as homologous with the belemnoid rostrum, which may indicate a close phylogenetic relationship between belemnites and at least some squid. Possible evolutionary pathways of the reduction of the functional phragmocone in squid ancestors are discussed. Several features such as the loss of shell calcification, deep water speciation, and the structure of the equilibrium organ point to a deep-water origin of squids.

  9. Development of Nb nanoSQUIDs based on SNS junctions for operation in high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Morosh, Viacheslav; Kieler, Oliver; Weimann, Thomas; Zorin, Alexander [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Mueller, Benedikt; Martinez-Perez, Maria Jose; Kleiner, Reinhold; Koelle, Dieter [Physikalisches Institut and Center for Quantum Science in LISA+, Universitaet Tuebingen (Germany)

    2016-07-01

    Investigation of the magnetization reversal of single magnetic nanoparticles requires SQUIDs with high spatial resolution, high spin sensitivity (a few Bohr magneton μ{sub B}) and at the same time sufficient stability in high magnetic fields. We fabricated dc nanoSQUIDs comprising overdamped SNS sandwich-type (Nb/HfTi/Nb) Josephson junctions using optimized technology based on combination of electron beam lithography and chemical-mechanical polishing. Our nanoSQUIDs have Josephson junctions with lateral dimensions ≤ 150 nm x 150 nm, effective loop areas < 0.05 μm{sup 2} and the distance between the Josephson junctions ≤ 100 nm. The feeding strip lines of the width ≤ 200 nm have been realized. The nanoSQUIDs have shown stable operation in external magnetic fields at least up to 250 mT. Sufficiently low level of flux noise resulting in spin sensitivity of few tens μ{sub B}/Hz{sup 1/2} has been demonstrated. A further reduction of the nanoSQUID size using our technology is possible.

  10. SQUID magnetometer using sensitivity correction signal for non-magnetic metal contaminants detection

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Toshifumi, E-mail: sakuta.k@usp.ac.jp; Ohashi, Masaharu; Sakuta, Ken

    2016-11-15

    Highlights: • A high-frequency excitation is necessary to detect nonmagnetic metals using SQUID. • It is possible to detect a high-frequency magnetic field using the open loop technique. • Open loop operation leads to a change in the conversion factor. • Conversion between voltage and magnetic field for open loop operation are examined. - Abstract: Measurement methods with SQUID can accurately detect small magnetic metal contaminants based on their magnetic remanence. But, a high-frequency excitation is necessary to detect nonmagnetic metals, on the base of contrasts in electric conductivity. In this work, an open loop technique is introduced to facilitate this. The SQUID is negative feedback controlled (flux locked loop (FLL) operation) for the low frequency range, which includes significant noise due to the movement of the magnetic body or the change of the ambient magnetic field composed of the geomagnetic field and technical signals, and it operates in an open loop configuration for the high frequency range. When using the open loop technique, negative feedback is not applied to the high frequency range. Consequently, the V–Φ characteristic changes due to various causes, which leads to variations in the conversion factor between the SQUID output voltage and the magnetic field. In this study, conversion techniques for the magnetic field for open loop operation of SQUID in the high frequency range are examined.

  11. NANO-SQUIDs based on niobium Dayem bridges for nanoscale applications

    Energy Technology Data Exchange (ETDEWEB)

    Granata, C; Esposito, E; Nappi, C; Ruggiero, B; Russo, M [Istituto di Cibernetica ' E. Caianiello' del Consiglio Nazionale delle Ricerche, 80078 Pozzuoli (Napoli) (Italy); Vettoliere, A; Walke, P [Also Universita degli Studi di Napoli ' Federico II' , Napoli (Italy); Silvestrini, P, E-mail: c.granata@cib.na.cnr.i [Dipartimento di Ingegneria dell' Informazione, Seconda Universita degli Studi di Napoli, Aversa(Caserta) (Italy)

    2010-06-01

    We report on the design, the fabrication and the performance of an integrated magnetic nano-sensor based on niobium dc-SQUID (Superconducting QUantum Interference Device) for nanoscale applications is presented. The nano-sensors are based on nanometric niobium constrictions (Dayem bridges) inserted in a square loop having a side length of 200 nm. Measurements of voltage-flux characteristic, flux to voltage transfer factor and noise performances are reported. In small signal mode, the sensors have shown a magnetic flux noise spectral density of 1.5 {mu}{Phi}{sub 0}/Hz{sup 1/2} corresponding to a spin sensitivity in unit of Bohr magneton of 60 spin/Hz{sup 1/2}. Supercurrent decay measurements of these devices are also reported. Such measurements provide useful information for applications which employ the SQUID as a trigger where the sensor works on the zero voltage state. The experimental data, have shown an intrinsic current fluctuation less than 0.2% of the critical current at liquid helium temperature, corresponding to an intrinsic sensor magnetic flux resolution of a few m{Phi}{sub 0}. In view of the nano-SQUID employments in the detection of small spin populations, the authors calculated the spin sensitivity and the magnetic response relative to the single spin, as a function of its position within the SQUID hole. The results show that the SQUID response depends strongly on the spin position.

  12. RF SQUID in the nonhysteretic regime with k2Ql>1

    International Nuclear Information System (INIS)

    Dmitrenko, I.M.; Tsoi, G.M.; Shnyrkov, V.I.; Kartsovnik, V.V.

    1982-01-01

    Experimental measurements of current-voltage, current-phase, amplitude-frequency, phase-frequency, and signal characteristics of an rf SQUID operating at a frequency of 30 MHz in the nonhysteretic regime (1 = 2πL 0 I 0 /phi/sub o/ 2 Ql>1. Here I 0 is the critical current of the weak link, L 0 is the SQUID ring inductance, k is the coefficient of coupling of the SQUID ring to a resonant tank circuit of quality Q, and phi 0 is the magnetic flux quantum. A numerical analysis of the above characteristics for all relevant parameter values close to those occurring under experimental conditions was performed for qualitative comparison with theory. The main difference from the traditional nonhysteretic regime of SQUID operation (k 2 Q1 12 V/Wb for the single-valued region of the signal characteristics. The results suggest that considerable improvement of rf SQUID resolution is possible in the regime k 2 Ql>1

  13. SQUID magnetometer using sensitivity correction signal for non-magnetic metal contaminants detection

    International Nuclear Information System (INIS)

    Yagi, Toshifumi; Ohashi, Masaharu; Sakuta, Ken

    2016-01-01

    Highlights: • A high-frequency excitation is necessary to detect nonmagnetic metals using SQUID. • It is possible to detect a high-frequency magnetic field using the open loop technique. • Open loop operation leads to a change in the conversion factor. • Conversion between voltage and magnetic field for open loop operation are examined. - Abstract: Measurement methods with SQUID can accurately detect small magnetic metal contaminants based on their magnetic remanence. But, a high-frequency excitation is necessary to detect nonmagnetic metals, on the base of contrasts in electric conductivity. In this work, an open loop technique is introduced to facilitate this. The SQUID is negative feedback controlled (flux locked loop (FLL) operation) for the low frequency range, which includes significant noise due to the movement of the magnetic body or the change of the ambient magnetic field composed of the geomagnetic field and technical signals, and it operates in an open loop configuration for the high frequency range. When using the open loop technique, negative feedback is not applied to the high frequency range. Consequently, the V–Φ characteristic changes due to various causes, which leads to variations in the conversion factor between the SQUID output voltage and the magnetic field. In this study, conversion techniques for the magnetic field for open loop operation of SQUID in the high frequency range are examined.

  14. Non-destructive inspection using HTS-SQUID on aluminum liner covered by CFRP

    International Nuclear Information System (INIS)

    Hatsukade, Y.; Yotsugi, K.; Sakaguchi, Y.; Tanaka, S.

    2007-01-01

    An eddy-current-based SQUID non-destructive inspection (NDI) system to detect deep-lying cracks in multi-layer composite-Al vessels was developed taking advantage of the uncontested sensitivity of HTS-SQUID in low-frequency range. An HTS-SQUID gradiometer was mounted in a pulse tube cryocooler. A pair of differential coils with C-shaped ferrite cores was employed to induce an enhanced eddy current in an Al vessel wrapped in a carbon fiber reinforced plastic (CFRP) cover. Ellipsoidal dome-shaped Al liners containing through cracks, which were made by pressure cycle tests, in the CFRP covers with total thickness of 6 mm (CFPR 3 mm, and Al 3 mm) were inspected by the system. While inducing eddy currents in the vessels with excitation fields at 100 Hz or 7 kHz, the vessels were rotated under the HTS-SQUID. Above the cracks, anomalous signals due to the cracks were clearly detected at both frequencies. These results suggested the SQUID-NDI technique would be a possible candidate for inspection of high-pressure multi-layer composite-Al vessels

  15. Non-destructive inspection using HTS-SQUID on aluminum liner covered by CFRP

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukade, Y. [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)], E-mail: hatukade@eco.tut.ac.jp; Yotsugi, K. [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan); Sakaguchi, Y. [SAMTECH Corporation, 1000-18 Enmyo-cho, Kashiwara City, Osaka 582-0027 (Japan); Tanaka, S. [Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2007-10-01

    An eddy-current-based SQUID non-destructive inspection (NDI) system to detect deep-lying cracks in multi-layer composite-Al vessels was developed taking advantage of the uncontested sensitivity of HTS-SQUID in low-frequency range. An HTS-SQUID gradiometer was mounted in a pulse tube cryocooler. A pair of differential coils with C-shaped ferrite cores was employed to induce an enhanced eddy current in an Al vessel wrapped in a carbon fiber reinforced plastic (CFRP) cover. Ellipsoidal dome-shaped Al liners containing through cracks, which were made by pressure cycle tests, in the CFRP covers with total thickness of 6 mm (CFPR 3 mm, and Al 3 mm) were inspected by the system. While inducing eddy currents in the vessels with excitation fields at 100 Hz or 7 kHz, the vessels were rotated under the HTS-SQUID. Above the cracks, anomalous signals due to the cracks were clearly detected at both frequencies. These results suggested the SQUID-NDI technique would be a possible candidate for inspection of high-pressure multi-layer composite-Al vessels.

  16. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  17. Thermodynamics of a closed-cycle gas flow system for cooling a HTc dc-SQUID magnetometer

    NARCIS (Netherlands)

    van den Bosch, P.J.; van den Bosch, P.J.; ter Brake, Hermanus J.M.; van den Eijkel, G.C.; Boelens, J.P.; Holland, Herman J.; Verberne, J.F.C.; Rogalla, Horst

    1994-01-01

    A multichannel high-Tc dc-SQUID based heart-magnetometer is currently under development in our laboratory. The system is cooled by a cooler that, due to its magnetic interference, has to be separated from the SQUID unit. In the present prototype system a closed-cycle gas flow was chosen as the

  18. 76 FR 3044 - Fisheries of the Exclusive Economic Zone Off Alaska; Sculpins, Sharks, Squid, and Octopus in the...

    Science.gov (United States)

    2011-01-19

    ..., Squid, and Octopus in the Gulf of Alaska AGENCY: National Marine Fisheries Service (NMFS), National... prohibiting directed fishing for sculpins, sharks, squid, and octopus in the Gulf of Alaska (GOA). This action..., and octopus in the GOA. DATES: Effective 1200 hrs, Alaska local time (A.l.t.), January 13, 2011...

  19. The male reproductive strategy of a deep-sea squid : sperm allocation, continuous production, and long-term storage of spermatophores in Histioteuthis miranda

    NARCIS (Netherlands)

    Hoving, Hendrik Jan T.; Lipinski, Marek R.; Dam, Lammertjan

    2010-01-01

    Squid are semelparous organisms. Much of what we know about squid reproduction relates to females, because few studies have addressed males and, although males are similarly challenged by semelparity, it remains virtually unknown what tactics squid have evolved to allocate sperm to spermatophores.

  20. Instrument development, data collection, and characteristics of practices, staff, and measures in the Improving Quality of Care in Diabetes (iQuaD) Study.

    Science.gov (United States)

    Eccles, Martin P; Hrisos, Susan; Francis, Jill J; Stamp, Elaine; Johnston, Marie; Hawthorne, Gillian; Steen, Nick; Grimshaw, Jeremy M; Elovainio, Marko; Presseau, Justin; Hunter, Margaret

    2011-06-09

    Type 2 diabetes is an increasingly prevalent chronic illness and an important cause of avoidable mortality. Patients are managed by the integrated activities of clinical and non-clinical members of primary care teams. This study aimed to: investigate theoretically-based organisational, team, and individual factors determining the multiple behaviours needed to manage diabetes; and identify multilevel determinants of different diabetes management behaviours and potential interventions to improve them. This paper describes the instrument development, study recruitment, characteristics of the study participating practices and their constituent healthcare professionals and administrative staff and reports descriptive analyses of the data collected. The study was a predictive study over a 12-month period. Practices (N = 99) were recruited from within the UK Medical Research Council General Practice Research Framework. We identified six behaviours chosen to cover a range of clinical activities (prescribing, non-prescribing), reflect decisions that were not necessarily straightforward (controlling blood pressure that was above target despite other drug treatment), and reflect recommended best practice as described by national guidelines. Practice attributes and a wide range of individually reported measures were assessed at baseline; measures of clinical outcome were collected over the ensuing 12 months, and a number of proxy measures of behaviour were collected at baseline and at 12 months. Data were collected by telephone interview, postal questionnaire (organisational and clinical) to practice staff, postal questionnaire to patients, and by computer data extraction query. All 99 practices completed a telephone interview and responded to baseline questionnaires. The organisational questionnaire was completed by 931/1236 (75.3%) administrative staff, 423/529 (80.0%) primary care doctors, and 255/314 (81.2%) nurses. Clinical questionnaires were completed by 326/361 (90

  1. Instrument development, data collection, and characteristics of practices, staff, and measures in the Improving Quality of Care in Diabetes (iQuaD) Study

    Science.gov (United States)

    2011-01-01

    Background Type 2 diabetes is an increasingly prevalent chronic illness and an important cause of avoidable mortality. Patients are managed by the integrated activities of clinical and non-clinical members of primary care teams. This study aimed to: investigate theoretically-based organisational, team, and individual factors determining the multiple behaviours needed to manage diabetes; and identify multilevel determinants of different diabetes management behaviours and potential interventions to improve them. This paper describes the instrument development, study recruitment, characteristics of the study participating practices and their constituent healthcare professionals and administrative staff and reports descriptive analyses of the data collected. Methods The study was a predictive study over a 12-month period. Practices (N = 99) were recruited from within the UK Medical Research Council General Practice Research Framework. We identified six behaviours chosen to cover a range of clinical activities (prescribing, non-prescribing), reflect decisions that were not necessarily straightforward (controlling blood pressure that was above target despite other drug treatment), and reflect recommended best practice as described by national guidelines. Practice attributes and a wide range of individually reported measures were assessed at baseline; measures of clinical outcome were collected over the ensuing 12 months, and a number of proxy measures of behaviour were collected at baseline and at 12 months. Data were collected by telephone interview, postal questionnaire (organisational and clinical) to practice staff, postal questionnaire to patients, and by computer data extraction query. Results All 99 practices completed a telephone interview and responded to baseline questionnaires. The organisational questionnaire was completed by 931/1236 (75.3%) administrative staff, 423/529 (80.0%) primary care doctors, and 255/314 (81.2%) nurses. Clinical questionnaires were

  2. Research on Intelligent Control System of DC SQUID Magnetometer Parameters for Multi-channel System

    Science.gov (United States)

    Chen, Hua; Yang, Kang; Lu, Li; Kong, Xiangyan; Wang, Hai; Wu, Jun; Wang, Yongliang

    2018-03-01

    In a multi-channel SQUID measurement system, adjusting device parameters to optimal condition for all channels is time-consuming. In this paper, an intelligent control system is presented to determine the optimal working point of devices which is automatic and more efficient comparing to the manual one. An optimal working point searching algorithm is introduced as the core component of the control system. In this algorithm, the bias voltage V_bias is step scanned to obtain the maximal value of the peak-to-peak current value I_pp of the SQUID magnetometer modulation curve. We choose this point as the optimal one. Using the above control system, more than 30 weakly damped SQUID magnetometers with area of 5 × 5 mm^2 or 10 × 10 mm^2 are adjusted and a 36-channel magnetocardiography system perfectly worked in a magnetically shielded room. The average white flux noise is 15 μΦ_0/Hz^{1/2}.

  3. Second order gradiometer and dc SQUID integrated on a planar substrate

    Science.gov (United States)

    van Nieuwenhuyzen, G. J.; de Waal, V. J.

    1985-02-01

    An integrated system of a thin-film niobium dc superconducting quantum interference device (SQUID) and a second order gradiometer on a planar substrate is described. The system consists of a dc SQUID with eight loops in parallel, each sensitive to the second derivative ∂2Bz/∂x2 of the magnetic field. The calculated SQUID inductance is 1.3 nH. With an overall size of 16×16.5 mm2 a sensitivity of 1.5×10-9 Tm-2 Hz-1/2 is obtained. The measured transfer function for uniform fields perpendicular to the plane of the gradiometer is 2.1×10-7 T Φ-10.

  4. Second order gradiometer and dc SQUID integrated on a planar substrate

    Energy Technology Data Exchange (ETDEWEB)

    van Nieuwenhuyzen, G.J.; de Waal, V.J.

    1985-02-15

    An integrated system of a thin-film niobium dc superconducting quantum interference device (SQUID) and a second order gradiometer on a planar substrate is described. The system consists of a dc SQUID with eight loops in parallel, each sensitive to the second derivative partial/sup 2/B/sub z//partialx/sup 2/ of the magnetic field. The calculated SQUID inductance is 1.3 nH. With an overall size of 16 x 16.5 mm/sup 2/ a sensitivity of 1.5 x 10/sup -9/ Tm/sup -2/ Hz/sup -1//sup ///sup 2/ is obtained. The measured transfer function for uniform fields perpendicular to the plane of the gradiometer is 2.1 x 10/sup -7/ T Phi/sup -1//sub 0/.

  5. A SQUID magnetometry system for a cryogenic neutron electric dipole moment experiment

    Energy Technology Data Exchange (ETDEWEB)

    Henry, S., E-mail: s.henry@physics.ox.ac.uk; Clarke, C.; Cottle, A.; Lynch, A.; Pipe, M.

    2014-11-01

    Precision magnetometry is an essential component of any neutron electric dipole moment experiment in order to correct shifts in the neutron precession frequency due to changes in the magnetic field. We have developed a magnetometry system using 12 SQUID sensors, designed to operate in 0.5 K superfluid helium. The pick-up loops located near the neutron cell are connected to the SQUID sensors by ∼2 m twisted wire pairs. The SQUID readout cables are run via an intermediate stage at 4.2 K. The system has been installed and tested in the cryoEDM apparatus at the ILL, Grenoble, and used to characterise the magnetic environment. Further tests in a suitable low noise environment confirm it meets our requirements.

  6. Squid measurement of the Verwey transition on epitaxial (1 0 0) magnetite thin films

    International Nuclear Information System (INIS)

    Dediu, V.; Arisi, E.; Bergenti, I.; Riminucci, A.; Solzi, M.; Pernechele, C.; Natali, M.

    2007-01-01

    We report results on epitaxial magnetite (Fe 3 O 4 ) thin films grown by electron beam ablation on (1 0 0) MgAl 2 O 4 substrates. At 120 K magnetite undergoes a structural and electronic transition, the so-called Verwey transition, at which magnetic and conducting properties of the material change. We observed the Verwey transition on epitaxial films with a thickness of 50 nm by comparing zero-field cooling (ZFC) and field cooling (FC) curves measured with a superconducting quantum interference device (SQUID) magnetometer. Observation of the Verwey transition by SQUID measurements in the films is sign of their high crystalline quality. Room temperature ferromagnetism has also been found by magneto-optical Kerr rotation (MOKE) and confirmed by SQUID measurements, with a hysteresis loop showing a coercive field of hundreds of Oe

  7. Direct readout flux locked loop circuit with automatic tuning of bias current and bias flux for high-Tc SQUID

    International Nuclear Information System (INIS)

    Hirano, T.; Nagaishi, T.; Itozaki, H.

    1999-01-01

    Measurement of high-frequency magnetic signals has been required from some SQUID applications. We fabricated a high-T c SQUID magnetic sensor system that can treat high-frequency signals. This system is composed of a SQUID, a preamplifier circuit, a flux locked loop (FLL) circuit with I/O and a personal computer and a PC card. We used the FLL circuit with no modulation to treat the high-frequency signal and to simplify the circuit. This system can treat a signal from dc to 1 MHz. All the sequence from tuning the SQUID to data acquisition can be done by a personal computer. This system successfully realized easy operation of SQUID measurement. (author)

  8. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    Energy Technology Data Exchange (ETDEWEB)

    Lu, D.F.; Fan, C.; Ruan, J.Z. [Midwest Superconductivity Inc., Lawrence, KS (United States)] [and others

    1994-12-31

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

  9. Trophic relationships between the jumbo squid (Dosidicus gigas and the lightfish (Vinciguerria lucetia in the Humboldt Current System off Peru

    Directory of Open Access Journals (Sweden)

    Rigoberto Rosas-Luis

    2011-04-01

    Full Text Available Acoustic surveys for assessing the biomass and distribution of the jumbo squid (Dosidicus gigas and the lightfish (Vinciguerria lucetia were carried out in the Humboldt Current System of Peru in 2007 and 2008. At the same time, 937 jumbo squid were caught and their stomach contents analyzed. The diet of the jumbo squid was dominated by mesopelagic fish. The first component of their fish diet was V. lucetia and the second component was the myctophid fish Diogenichthys laternatus. Acoustic biomass estimates of these species show that V. lucetia is an important component in aggregative structures in the Humboldt Current System of Peru and its distribution and movements are closely related to the migratory movements of the jumbo squid. The trophic relationship observed between D. gigas and V. lucetia promotes an increase in jumbo squid biomass and, has a positive trophic effect on the ocean ecosystem.

  10. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    International Nuclear Information System (INIS)

    Lu, D.F.; Fan, C.; Ruan, J.Z.

    1994-01-01

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology

  11. Axon-Schwann cell interaction in the squid nerve fibre.

    Science.gov (United States)

    Villegas, J

    1972-09-01

    The electrical properties of Schwann cells and the effects of neuronal impulses on their membrane potential have been studied in the giant nerve fibre of the squid.1. The behaviour of the Schwann cell membrane to current injection into the cell was ohmic. No impulse-like responses were observed with displacements of 35 mV in the membrane potential. The resistance of the Schwann cell membrane was found to be approximately 10(3) Omega cm(2).2. A long-lasting hyperpolarization is observed in the Schwann cells following the conduction of impulse trains by the axon. Whereas the propagation of a single impulse had little effect, prolonged stimulation of the fibre at 250 impulses/sec was followed by a hyperpolarization of the Schwann cell that gradually declined over a period of several minutes.3. The prolonged effects of nerve impulse trains on the Schwann cell were similar to those produced by depolarizing current pulses applied to the axon by the voltage-clamp technique. Thus, a series of depolarizing pulses in the axon was followed by a long-lasting hyperpolarization of the Schwann cells. In contrast, the application of a series of hyperpolarizing 100 mV pulses at a frequency of 1/sec had no apparent effects.4. Changes in the external potassium concentration did not reproduce the long-lasting effects of nerve excitation.5. The hyperpolarizing effects of impulse trains were abolished by the incubation of the nerve fibre in a sea-water solution containing trypsin.6. These findings are discussed in relation to the possible mechanisms that might be responsible for the long-lasting hyperpolarizations of the Schwann cells.

  12. Quantum decay of metastable current states in rf squids

    International Nuclear Information System (INIS)

    Dmitrenko, I.M.; Khlus, V.A.; Tsoj, C.M.; Shnyrkov, V.I.

    1985-01-01

    Quantum decay of metastable current states in a rf SQUID superconducting ring of a hysteresis mode are considered. Point contacts are used as a Josephson weak link. The first derivative of rf IVC, dVsub(T)/dIsub(RF), is measured which gives the dependence of the density of decay probability on the amplitude of magnetic flux oscillations in the ring. The temperature dependence of probability distribution width between 4.2 and 0.5 K suggests that for most of high-ohmic contacts Nb-Nb, Nb-Ag-Nb the quantum mechanisms of decay become dominant beginning with the temperature of about 2 K. The experimental parameters of distribution of decay probability in the quantum limit are compared to those calculated by the theory of macroscopic quantum tunneling in the limit of high and low dissipation. The experimental values of probability density distribution width and characteristic quantum temperature are higher than the theoretical ones, the fact can be attributed to the deviation of current-phase relation of contact from a sinusoidal one. Besides, some contacts seem to correspond to the case of an intermediate value of dissipation. As the frequency of rf oscillations varies from 30 to 6 MHz, the distribution width remains unchanged in accordance with the theory of quantum tunneling decay of metastable current state in the ring in the limit of high damping. At low temperatures (T approximately 0.5 K), and rather small damping coefficient, the density of probability displays anomalous peaks when the amplitude of rf oscillations is lower considerably than the critical vaiue of magnetic flux in the ring

  13. Quality assessment of recent evidence-based clinical practice guidelines for management of type 2 diabetes mellitus in adults using the AGREE II instrument.

    Science.gov (United States)

    Anwer, Muhammad A; Al-Fahed, Ousama B; Arif, Samir I; Amer, Yasser S; Titi, Maher A; Al-Rukban, Mohammed O

    2018-02-01

    Type 2 diabetes mellitus (T2DM) is a worldwide and national public health problem that has a great impact on the population in Saudi Arabia. High-quality clinical practice guidelines (CPGs) are cornerstones in improving the health care provided for patients with diabetes. This study evaluated the methodological rigour, transparency, and applicability of recently published CPGs. Our group conducted a systematic search for recently published CPGs for T2DM. The searching and screening for Source CPGs were guided by tools from the ADAPTE methods with specific inclusion/exclusion criteria. Five reviewers using the second version of the Appraisal of Guidelines for Research and Evaluation (AGREE II) Instrument independently assessed the quality of the retrieved Source CPGs. Domains of Scope and purpose and Clarity of presentation received the highest scores in all CPGs. Most of the assessed CPGs (86%) were considered with high overall quality and were recommended for use. Rigour of development and applicability domains were together highest in 3 CPGs (43%). The overall high quality of DM CPGs published in the last 3 years demonstrated the continuous development and improvement in CPG methodologies and standards. Health care professionals should consider the quality of any CPG for T2DM before deciding to use it in their daily clinical practice. Three CPGs have been identified, using the AGREE criteria, as high-quality and trustworthy. Ideally, the resources provided by the AGREE trust including the AGREE II Instrument should be used by a clinician to scan through the large number of published T2DM CPGs to identify the CPGs with high methodological quality and applicability. © 2017 John Wiley & Sons, Ltd.

  14. The DCU: the detector control unit of the SAFARI instrument onboard SPICA

    Science.gov (United States)

    Clénet, A.; Ravera, L.; Bertrand, B.; Cros, A.; Hou, R.; Jackson, B. D.; van Leeuwen, B. J.; Van Loon, D.; Parot, Y.; Pointecouteau, E.; Sournac, A.; Ta, N.

    2012-09-01

    The SpicA FAR infrared Instrument (SAFARI) is a European instrument for the infrared domain telescope SPICA, a JAXA space mission. The SAFARI detectors are Transistor Edge Sensors (TES) arranged in 3 matrixes. The TES front end electronic is based on Superconducting Quantum Interference Devices (SQUIDs) and it does the readout of the 3500 detectors with Frequency Division Multiplexing (FDM) type architecture. The Detector Control Unit (DCU), contributed by IRAP, manages the readout of the TES by computing and providing the AC-bias signals (1 - 3 MHz) to the TES and by computing the demodulation of the returning signals. The SQUID being highly non-linear, the DCU has also to provide a feedback signal to increase the SQUID dynamic. Because of the propagation delay in the cables and the processing time, a classic feedback will not be stable for AC-bias frequencies up to 3 MHz. The DCU uses a specific technique to compensate for those delays: the BaseBand FeedBack (BBFB). This digital data processing is done for the 3500 pixels in parallel. Thus, to keep the DCU power budget within its allocation we have to specifically optimize the architecture of the digital circuit with respect to the power consumption. In this paper we will mainly present the DCU architecture. We will particularly focus on the BBFB technique used to linearize the SQUID and on the optimization done to reduce the power consumption of the digital processing circuit.

  15. Safe sleep practices in a New Zealand community and development of a Sudden Unexpected Death in Infancy (SUDI) risk assessment instrument.

    Science.gov (United States)

    Galland, Barbara C; Gray, Andrew; Sayers, Rachel M; Heath, Anne-Louise M; Lawrence, Julie; Taylor, Rachael; Taylor, Barry J

    2014-10-13

    Interventions to prevent sudden unexpected death in infancy (SUDI) have generally been population wide interventions instituted after case-control studies identified specific childcare practices associated with sudden death. While successful overall, in New Zealand (NZ), the rates are still relatively high by international comparison. This study aims to describe childcare practices related to SUDI prevention messages in a New Zealand community, and to develop and explore the utility of a risk assessment instrument based on international guidelines and evidence. Prospective longitudinal study of 209 infants recruited antenatally. Participant characteristics and infant care data were collected by questionnaire at: baseline (third trimester), and monthly from infant age 3 weeks through 23 weeks. Published meta-analyses data were used to estimate individual risk ratios for 6 important SUDI risk factors which, when combined, yielded a "SUDI risk score". Most infants were at low risk for SUDI with 72% at the lowest or slightly elevated risk (combined risk ratio ≤1.5). There was a high prevalence of the safe practices: supine sleeping (86-89% over 3-19 weeks), mother not smoking (90-92% over 3-19 weeks), and not bed sharing at a young age (87% at 3 weeks). Five independent predictors of a high SUDI risk score were: higher parity (P =0.028), younger age (P =0.030), not working or caring for other children antenatally (P =0.031), higher depression scores antenatally (P =0.036), and lower education (P =0.042). Groups within the community identified as priorities for education about safe sleep practices beyond standard care are mothers who are young, have high parity, low educational levels, and have symptoms of depression antenatally. These findings emphasize the importance of addressing maternal depression as a modifiable risk factor in pregnancy.

  16. Detection of thermal aging degradation and plastic strain damage for duplex stainless steel using SQUID sensor

    International Nuclear Information System (INIS)

    Otaka, M.; Evanson, S.; Hesegawa, K.; Takaku, K.

    1991-01-01

    An apparatus using a SQUID sensor is developed for nondestructive inspection. The measurements are obtained with the SQUID sensor located approximately 150 mm from the specimen. The degradation of thermal aging and plastic strain for duplex stainless steel is successfully detected independently from the magnetic characterization measurements. The magnetic flux density under high polarizing field is found to be independent of thermal aging. Coercive force increases with thermal aging time. On the other hand, the magnetic flux density under high field increases with the plastic strain. Coercive force is found to be independent of the plastic strain. (author)

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  19. Verification of the weak equivalence principle of supports and heavy masses using SQUIDs; Ueberpruefung des schwachen Aequivalenzprinzips von Traegern und schwerer Masse mittels Squids

    Energy Technology Data Exchange (ETDEWEB)

    Vodel, W.; Nietzsche, S.; Neubert, R. [Friedrich-Schiller-Universitaet Jena (Germany). Inst. fuer Festkoerperphysik; Dittus, H. [Univ. Bremen (Germany). Zentrum fuer angewandte Raumfahrttechnologie und Mikrogravitation

    2003-07-01

    The weak equivalence principle is one of the fundamental hypotheses of general relativity and one of the key elements of our physical picture of the world, but since Galileo there has been no satisfactory way of verifying it. The new SQUID technology may offer a solution. The contribution presents the experiments of Jena University. Applications are envisaged, e.g., in the STEP space mission of the NASA/ESA. [German] Das Schwache Aequivalenzprinzip ist eine der grundlegenden Hypothesen der Allgemeinen Relativitaetstheorie und damit einer der Grundpfeiler unseres physikalischen Weltbildes. Obwohl es seit den ersten Experimenten von Galileo Galilei am Schiefen Turm zu Pisa im Jahre 1638 bis heute schon zahlreiche und immer praeziser werdende Messungen zur Ueberpruefung der Aequivalenz von schwerer und traeger Masse gegeben hat, ist die strenge Gueltigkeit dieses fundamentalen Prinzips experimentell vergleichsweise unzureichend bestimmt. Neuere Methoden, wie der Einsatz SQUID-basierter Messtechnik und die Durchfuehrung von Experimenten auf Satelliten, lassen Verbesserungen schon in naher Zukunft erwarten, so dass theoretische Ueberlegungen zur Vereinigung aller uns bekannten physikalischen Wechselwirkungen, die eine Verletzung des Schwachen Aequivalenzprinzips voraussagen, experimentell eingegrenzt werden koennten. Der Beitrag gibt einen Ueberblick ueber die an der Universitaet Jena entwickelte SQUID-basierte Messtechnik zum Test des Aequivalenzprinzips und fasst die bisher bei Freifallversuchen am Fallturm Bremen erzielten experimentellen Ergebnisse zusammen. Ein Ausblick auf die geplante Raumfahrtmission STEP der NASA/ESA zum Praezisionstest des Schwachen Aequivalenzprinzips schliesst den Beitrag ab. (orig.)

  20. Instrument processing: knowledge and practice among manicurists/pedicurists Processamento de instrumentos: conhecimento e prática entre manicures/pedicures

    Directory of Open Access Journals (Sweden)

    Juliana Ladeira Garbaccio

    2016-02-01

    Full Text Available Objective: to evaluate the knowledge and practices of instrument processing by manicurists/pedicurists in beauty salons in the city of Belo Horizonte, Brazil. Method: This was a survey-type cross-sectional research with manicurists/pedicurists, between June 2012 and March 2013 in 235 beauty salons in Brazil. The answers were categorized using the Statistical Package for the Social Sciences, by means of descriptive statistics, Pearson’s Chi-Squared or Fisher’s exact tests, and multivariate binary logistic regression, to analyze the influence of sociodemographic variables. Results: The majority (68.1% correctly defined sterilization; however, the adherence to moist heat (autoclave was low (35.3%. The temperature and the exposure time to sterilization methods varied, with the majority (44.7% citing a minimum of 200°C for 60 to 90 minutes (32.8%. The respondents reported reusing disposable instruments with their customers, but pointed out individual use of instruments as the correct procedure (90.6%. Conclusion: Despite their knowledge, professionals practice was inappropriate regarding instrument processing, which can place their own health and that of their customers at risk. ============================================================================================= Objetivo: Avaliar os conhecimentos e práticas de tratamento dos instrumentos utilizados por manicures/pedicures em salões de beleza na cidade de Belo Horizonte, Brasil. Método: Pesquisa transversal, do tipo inquérito com manicures/pedicures, entre junho de 2012 e março 2013, em 235 salões de beleza. As respostas foram categorizadas e analisadas utilizando o programa Statistical Package for the Social Sciences, por meio de estatísticas descritivas, de Pearson teste exato de Fisher, Qui quadrado ou/e regressão logística binária multivariada para analisar a influência das variáveis sociodemográficas. Resultados: A maioria (68,1% definiu esterilização corretamente. No

  1. Cadmium content in fresh and canned squid (Loligo opalescens) from the Pacific coastal waters of California (USA).

    Science.gov (United States)

    Galitsopoulou, A; Georgantelis, D; Kontominas, M G

    2009-01-01

    Cadmium (Cd) levels were determined in 70 samples of mantle tissue and 70 whole individual squid (Loligo opalescens; commercially known as California squid). Samples were collected from the coastal zones of California (USA) during the period 2007/2008. To further investigate consumer exposure to processed fishery products, cadmium concentration was also determined in 200 canned samples of squid. Cd concentrations in raw mantle were low, between 0.01 and 0.29 mg kg(-1) and below the tolerance limit of current regulations (1 mg kg(-1)). Respective concentrations in whole individuals were significantly higher, ranging from 0.51 to 1.18 mg kg(-1), attributed to the presence of the visceral portion in whole squid samples. Cd concentrations varied in relation to age and sex of squid, indicating that several physiological factors may influence accumulation. Furthermore, canning of squid substantially enhanced Cd levels. Cd concentration ranged 0.17-0.67 mg kg(-1) in canned mantle tissue and 0.86-2.07 mg kg(-1) in canned whole squid samples, due to both concentration after canning and movement of the metal between different tissues. Several biological compounds, including metallothioneins, nucleic acids and enzymes, may affect Cd concentrations in commercial fishery products.

  2. Effects of Gamma Irradiation on Shelf-Life and Sensory Scores of Squid Sundae under Accelerated Storage Conditions

    International Nuclear Information System (INIS)

    Kim, H.J.; Kim, K.B.W.R.; Kim, D.H.; Sunwoo, C.; Jung, S.A.; Jeong, D.H.; Jung, H.Y.; Ahn, D.H.; Kim, J.H.; Lee, J.W.; Do, S.R.; Byun, M.W.

    2012-01-01

    This study was conducted to examine the effects of gamma irradiation on the shelf-life and sensory scores of squid Sundae under accelerated storage conditions. Squid Sundae was stored at 37°C for 35 days following gamma irradiation at doses of 0, 10, and 20 kGy. For total viable cell counts, control and gamma-irradiated (GI) (10 kGy) squid Sundae were already spoiled in 4 days, whereas GI (20 kGy) squid Sundae showed complete suppression of bacterial growth during storage. There were no significant changes in pH values compared to the control. The VBN and TBARS (thiobarbituric acid reactive substance) values of GI (20 kGy) squid Sundae were significantly lower than those of the control. In addition, the induction period of GI (20 kGy) squid Sundae as measured by a Rancimat showed a higher level compared to that of the control. In the sensory evaluation, there were no significant changes between the control and GI samples. These results suggest that a dose of 20 kGy is the optimum and effective dose for preservation of squid Sundae. (author)

  3. Potential use of stable isotope and fatty acid analyses for traceability of geographic origins of jumbo squid (Dosidicus gigas).

    Science.gov (United States)

    Gong, Yi; Li, Yunkai; Chen, Xinjun; Chen, Ling

    2018-04-15

    Squid is an important seafood resource for Asian and European countries. With the continuous development of processed squid products, an effective traceability system has become increasingly prominent. Here, we attempt to trace the fishery products of the main target species, jumbo squid (Dosidicus gigas), by using biochemical tracers. Carbon and nitrogen isotope ratios (δ 13 C and δ 15 N values) and fatty acid profiles were identified in squid from three harvest locations in the eastern Pacific Ocean by isotope ratio mass spectrometry and gas chromatography/mass spectrometry, respectively. Comparative analysis was used to evaluate the geographic variations in tracers and to identify the suitable discriminatory variables among origins. Significant spatial variations were found in isotopic values and fatty acid profiles in squid muscle tissues, possibly because of different food availability and/or oceanographic conditions that each group experiences at a given location. The stepwise discriminant analysis indicated that δ 15 N, C16:1n7, C17:1n7, C18:2n6, C20:1 and C20:4n6 were effective variables at differentiating origin. Combined use of stable isotope ratios and fatty acid analyses could trace geographic origins of jumbo squid. This study provides an alternative approach for improving authenticity evaluation of commercial squid products. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Expression of squid iridescence depends on environmental luminance and peripheral ganglion control.

    Science.gov (United States)

    Gonzalez-Bellido, P T; Wardill, T J; Buresch, K C; Ulmer, K M; Hanlon, R T

    2014-03-15

    Squid display impressive changes in body coloration that are afforded by two types of dynamic skin elements: structural iridophores (which produce iridescence) and pigmented chromatophores. Both color elements are neurally controlled, but nothing is known about the iridescence circuit, or the environmental cues, that elicit iridescence expression. To tackle this knowledge gap, we performed denervation, electrical stimulation and behavioral experiments using the long-fin squid, Doryteuthis pealeii. We show that while the pigmentary and iridescence circuits originate in the brain, they are wired differently in the periphery: (1) the iridescence signals are routed through a peripheral center called the stellate ganglion and (2) the iridescence motor neurons likely originate within this ganglion (as revealed by nerve fluorescence dye fills). Cutting the inputs to the stellate ganglion that descend from the brain shifts highly reflective iridophores into a transparent state. Taken together, these findings suggest that although brain commands are necessary for expression of iridescence, integration with peripheral information in the stellate ganglion could modulate the final output. We also demonstrate that squid change their iridescence brightness in response to environmental luminance; such changes are robust but slow (minutes to hours). The squid's ability to alter its iridescence levels may improve camouflage under different lighting intensities.

  5. Effect of electron beam on the microbiological and sensory characteristics of squid jeotkal and its ingredients

    International Nuclear Information System (INIS)

    Liu Xiande; Piao Linghua

    2012-01-01

    A seasoned squid Jeotkal, Koran traditional fermented seafood, and its ingredients for manufacturing, including red hot pepper powder and ground garlic were irradiated by 0, 0.5, 1, 2 and 5 kGy electron beam and stored at 4 ℃ for 4 weeks to determine the changes of microorganisms and sensory characteristics. The initial contamination of squid Jeotkal such as total aerobic bacteria, yeast and mold, and coliform bacterial were at the levels of 2.88, 3.04 and 4.20 logCFU/g, respectively. However, 5 kGy electron beam irradiation reduced the total aerobic bacteria about 1 logCFU/g. Yeast and mold and coliform bacterial were reduced 1 ∼ 2 logCFU/g after 2 kGy irradiation and reached to undetected level when the sample was irradiated at 5 kGy and following storage at 4 ℃ for 4 weeks. Sensory characteristics showed that 5 kGy electron beam irradiation did not adversely affect overall acceptability of squid Jeotkal and its ingredients during 4 ℃ storage. Therefore, electron beam irradiation is one of the possible methods to improve storage stability of seasoned squid Jeotkal. (authors)

  6. Highly balanced gradiometer systems based on HTS-SQUIDs for the use in magnetically unshielded environment

    NARCIS (Netherlands)

    Borgmann, H.J.R.; Rijpma, A.P.; ter Brake, Hermanus J.M.; Rogalla, Horst; David, P.

    1999-01-01

    Two different concepts for gradiometer formation were tested applying high-temperature rf SQUIDs operated at 77 K in liquid nitrogen. All gradiometer systems are fully based on magnetometers. The first concept applies a compensating magnetometer at different positions to actively cancel the magnetic

  7. Integrated de SQUID magnetometer with high dV/dB

    International Nuclear Information System (INIS)

    Drung, D.; Cantor, R.; Peters, M.; Ryhanen, T.; Kochi, H.

    1991-01-01

    This paper presents a directly coupled dc SQUID magnetometer with very simple feedback electronics. The magnetometer has been integrated on a 7.2 x 7.2 mm 2 chip and fabricated using a four-level Nb/Si x N v /Nb process. Eight pick-up loops are connected in parallel to directly form the SQUID inductance of about 0.4 nH which leads to a high sensitivity B/Φ = 0.47 nT/Φ. An Additional Positive Feedback (APF) circuit on the magnetometer chip has been used to increase the gradient of the V-μ characteristic to dV/dΦ ≅ 300 μV/Φ 0 at the SQUID operating point. The resulting gradient of the transfer function of dV/dB ≅ 640 μV/nT makes it possible to directly read out the SQUID without helium temperature impedance matching circuits or flux modulation techniques

  8. Magnetic properties of thin Ni films measured by a dc SQUID-based magnetic microscope

    DEFF Research Database (Denmark)

    Snigirev, O.V.; Andreev, K.E.; Tishin, A.M.

    1997-01-01

    We have applied a scanning HTS (high-temperature superconductor) de SQUID (superconducting quantum interference device) -based magnetic microscope to study the magnetic properties of Au/Ni/Si(100) films in the thickness range from 8 to 200 Angstrom at T = 77 K. A one-domain structure with in...

  9. The effects of jig color and lunar bright on coastal squid jigging ...

    African Journals Online (AJOL)

    Squid jigging experiments were carried out to determine whether differences occurred between different colors and lunar brightness in Middle Eastern coast of Aegean Sea. Five different colors of jigs (red, blue, green, orange and white) were used together in same angle. According to one-way analysis of variance results, ...

  10. Rotational population patterns and searches for the nuclear SQUID (Superconducting Quantum Interference Device)

    International Nuclear Information System (INIS)

    Canto, L.F.; Donangelo, R.J.; Farhan, A.R.; Guidry, M.W.; Rasmussen, J.O.; Ring, P.; Stoyer, M.A.

    1989-11-01

    This paper presents new theoretical results for rotational population patterns in the nuclear SQUID effect. (The term nuclear SQUID is in analogy to the solid-state Superconducting Quantum Interference Devices.) The SQUID effect is an interesting new twist to an old quest to understand Coriolis anti-pairing (CAP) effects in nuclear rotational bands. Two-neutron transfer reaction cross sections among high-spin states have long been touted as more specific CAP probes than other nuclear properties. Heavy projectiles like Sn or Pb generally are recommended to pump the deformed nucleus to as high spin as possible for transfer. The interference and sign reversal of 2n transfer amplitudes at high spin, as predicted in the early SQUID work imposes the difficult requirement of Coulomb pumping to near back-bending spins at closest approach. For Pb on rare earths we find a dramatic departure from sudden-approximation, so that the population depression occurs as low as final spin 10h. 14 refs., 8 figs

  11. Comparison live adult Artemia and squid meat on the growth of Penaeid shrimp Metapenaeus dobsoni (Miers)

    Digital Repository Service at National Institute of Oceanography (India)

    Nair, S.R.S.; Achuthankutty, C.T.; Royan, J.P.

    An experiment lasting 14 weeks was conducted to compare the efficiency of live adult Artemia with fresh squid meat on growth of penaeid shrimp Metapenaeus dobsoni. The shrimps were found actively feeding on live Artemia and grew 84% more than those...

  12. A simple method for checking the balance of gradiometers used with squids

    International Nuclear Information System (INIS)

    Eghrari, I.R.; Ribeiro, P.C.

    1978-11-01

    A simple technique for detecting the degree of balance of first order gradiometers before connecting them to the SQUID is described. The effect of thermal cycling on this balance is given for different materials used in the construction of the gradiometers [pt

  13. Ocean acidification responses in paralarval squid swimming behavior using a novel 3D tracking system

    KAUST Repository

    Zakroff, Casey J.; Mooney, T. Aran; Wirth, Colin

    2017-01-01

    . pealeii from eggs reared under chronic OA demonstrated measurable impairments to swimming activity and control. This required the development of a novel, cost-effective, and robust method for 3D motion tracking and analysis. Squid eggs were reared in pCO2

  14. Rapid Associative Learning and Stable Long-Term Memory in the Squid Euprymna scolopes.

    Science.gov (United States)

    Zepeda, Emily A; Veline, Robert J; Crook, Robyn J

    2017-06-01

    Learning and memory in cephalopod molluscs have received intensive study because of cephalopods' complex behavioral repertoire and relatively accessible nervous systems. While most of this research has been conducted using octopus and cuttlefish species, there has been relatively little work on squid. Euprymna scolopes Berry, 1913, a sepiolid squid, is a promising model for further exploration of cephalopod cognition. These small squid have been studied in detail for their symbiotic relationship with bioluminescent bacteria, and their short generation time and successful captive breeding through multiple generations make them appealing models for neurobiological research. However, little is known about their behavior or cognitive ability. Using the well-established "prawn-in-the-tube" assay of learning and memory, we show that within a single 10-min trial E. scolopes learns to inhibit its predatory behavior, and after three trials it can retain this memory for at least 12 d. Rapid learning and very long-term retention were apparent under two different training schedules. To our knowledge, this study is the first demonstration of learning and memory in this species as well as the first demonstration of associative learning in any squid.

  15. A nitrogen triple-point thermal storage unit for cooling a SQUID magnetometer

    NARCIS (Netherlands)

    Rijpma, A.P.; Meenderink, D.J.; Reincke, H.A.; Venhorst, G.C.F.; Holland, H.J.; Brake, ter H.J.M.

    2005-01-01

    In order to achieve turnkey operation, the use is planned of cryocoolers to cool a SQUID magnetometer system. To minimize the magnetical and mech. interference from the coolers, they are switched off during the actual measurements. Consequently, a thermal storage unit (TSU) is required with

  16. A nitrogen triple-point thermal storage unit for cooling a SQUID magnetometer

    NARCIS (Netherlands)

    Rijpma, A.P.; Meenderink, D.J.; Reincke, H.A.; Venhorst, G.C.F.; Venhorst, G.C.F.; Holland, Herman J.; ter Brake, Hermanus J.M.

    2005-01-01

    In order to achieve turnkey operation, we plan to use cryocoolers to cool a SQUID magnetometer system. To minimize the magnetical and mechanical interference from the coolers, we intend to switch them off during the actual measurements. Consequently, a thermal storage unit (TSU) is required with

  17. Closed-cycle gas flow system for cooling a HTc dc-SQUID magnetometer

    NARCIS (Netherlands)

    Bosch, van den P.J.; Holland, H.J.; Brake, ter H.J.M.; Rogalla, H.

    1994-01-01

    A closed-cycle gas flow system for cooling a high-crit. temp. d.c.-superconducting quantum interference device (SQUID) magnetometer by means of a cryocooler has been designed, constructed and tested. The magnetometer is aimed to measure heart signals with a sensitivity of 0.1 pT/Hz1/2. The required

  18. Analysis of metal catalyst content in magnetically filtered SWCNTs by SQUID magnetometry

    Czech Academy of Sciences Publication Activity Database

    Pacáková, Barbara; Komínková, Zuzana; Vejpravová, Jana; Kalbáč, Martin

    2015-01-01

    Roč. 50, č. 6 (2015), s. 2544-2553 ISSN 0022-2461 R&D Projects: GA ČR GAP204/10/1677 Institutional support: RVO:68378271 ; RVO:61388955 Keywords : single-wall carbon nanotubes * nanoparticles * magnetic filtration * SQUID Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.302, year: 2015

  19. Characterization of single-core magnetite nanoparticles for magnetic imaging by SQUID relaxometry

    International Nuclear Information System (INIS)

    Adolphi, Natalie L; Huber, Dale L; Monson, Todd C; Provencio, Paula P; Bryant, Howard C; Fegan, Danielle L; Tessier, Trace E; Flynn, Edward R; Lim, JitKang; Majetich, Sara A; Trujillo, Jason E; Lovato, Debbie M; Butler, Kimberly S; Larson, Richard S; Hathaway, Helen J

    2010-01-01

    Optimizing the sensitivity of SQUID (superconducting quantum interference device) relaxometry for detecting cell-targeted magnetic nanoparticles for in vivo diagnostics requires nanoparticles with a narrow particle size distribution to ensure that the Neel relaxation times fall within the measurement timescale (50 ms-2 s, in this work). To determine the optimum particle size, single-core magnetite nanoparticles (with nominal average diameters 20, 25, 30 and 35 nm) were characterized by SQUID relaxometry, transmission electron microscopy, SQUID susceptometry, dynamic light scattering and zeta potential analysis. The SQUID relaxometry signal (detected magnetic moment/kg) from both the 25 nm and 30 nm particles was an improvement over previously studied multi-core particles. However, the detected moments were an order of magnitude lower than predicted based on a simple model that takes into account the measured size distributions (but neglects dipolar interactions and polydispersity of the anisotropy energy density), indicating that improved control of several different nanoparticle properties (size, shape and coating thickness) will be required to achieve the highest detection sensitivity. Antibody conjugation and cell incubation experiments show that single-core particles enable a higher detected moment per cell, but also demonstrate the need for improved surface treatments to mitigate aggregation and improve specificity.

  20. Characterization of single-core magnetite nanoparticles for magnetic imaging by SQUID relaxometry

    Energy Technology Data Exchange (ETDEWEB)

    Adolphi, Natalie L [Department of Biochemistry and Molecular Biology, University of New Mexico, Albuquerque, NM 87131 (United States); Huber, Dale L; Monson, Todd C; Provencio, Paula P [Sandia National Laboratories, P. O. Box 5800, Albuquerque, NM 87185 (United States); Bryant, Howard C; Fegan, Danielle L; Tessier, Trace E; Flynn, Edward R [Senior Scientific, LLC, 11109 Country Club NE, Albuquerque, NM 87111 (United States); Lim, JitKang; Majetich, Sara A [Department of Physics, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Trujillo, Jason E; Lovato, Debbie M; Butler, Kimberly S; Larson, Richard S [Department of Pathology, Cancer Research and Treatment Center, University of New Mexico, Albuquerque, NM 87131 (United States); Hathaway, Helen J, E-mail: NAdolphi@salud.unm.ed [Department of Cell Biology and Physiology, University of New Mexico, Albuquerque, NM 87131 (United States)

    2010-10-07

    Optimizing the sensitivity of SQUID (superconducting quantum interference device) relaxometry for detecting cell-targeted magnetic nanoparticles for in vivo diagnostics requires nanoparticles with a narrow particle size distribution to ensure that the Neel relaxation times fall within the measurement timescale (50 ms-2 s, in this work). To determine the optimum particle size, single-core magnetite nanoparticles (with nominal average diameters 20, 25, 30 and 35 nm) were characterized by SQUID relaxometry, transmission electron microscopy, SQUID susceptometry, dynamic light scattering and zeta potential analysis. The SQUID relaxometry signal (detected magnetic moment/kg) from both the 25 nm and 30 nm particles was an improvement over previously studied multi-core particles. However, the detected moments were an order of magnitude lower than predicted based on a simple model that takes into account the measured size distributions (but neglects dipolar interactions and polydispersity of the anisotropy energy density), indicating that improved control of several different nanoparticle properties (size, shape and coating thickness) will be required to achieve the highest detection sensitivity. Antibody conjugation and cell incubation experiments show that single-core particles enable a higher detected moment per cell, but also demonstrate the need for improved surface treatments to mitigate aggregation and improve specificity.

  1. Conversion of Squid Pens to Chitosanases and Proteases via Paenibacillus sp. TKU042

    Directory of Open Access Journals (Sweden)

    Chien Thang Doan

    2018-03-01

    Full Text Available Chitosanases and proteases have received much attention due to their wide range of applications. Four kinds of chitinous materials, squid pens, shrimp heads, demineralized shrimp shells and demineralized crab shells, were used as the sole carbon and nitrogen (C/N source to produce chitosanases, proteases and α-glucosidase inhibitors (αGI by four different strains of Paenibacillus. Chitosanase productivity was highest in the culture supernatants using squid pens as the sole C/N source. The maximum chitosanase activity of fermented squid pens (0.759 U/mL was compared to that of fermented shrimp heads (0.397 U/mL, demineralized shrimp shells (0.201 U/mL and demineralized crab shells (0.216 U/mL. A squid pen concentration of 0.5% was suitable for chitosanase, protease and αGI production via Paenibacillus sp. TKU042. Multi-purification, including ethanol precipitation and column chromatography of Macro-Prep High S as well as Macro-Prep DEAE (diethylaminoethyl, led to the isolation of Paenibacillus sp. TKU042 chitosanase and protease with molecular weights of 70 and 35 kDa, respectively. For comparison, 16 chitinolytic bacteria, including strains of Paenibacillus, were investigated for the production of chitinase, exochitinase, chitosanase, protease and αGI using two kinds of chitinous sources.

  2. Characterization and demonstration results of a SQUID magnetometer system developed for geomagnetic field measurements

    Science.gov (United States)

    Kawai, J.; Miyamoto, M.; Kawabata, M.; Nosé, M.; Haruta, Y.; Uehara, G.

    2017-08-01

    We characterized a low temperature superconducting quantum interference device (SQUID) magnetometer system developed for high-sensitivity geomagnetic field measurement, and demonstrated the detection of weak geomagnetic signals. The SQUID magnetometer system is comprised of three-axis SQUID magnetometers housed in a glass fiber reinforced plastic cryostat, readout electronics with flux locked loop (FLL), a 24-bit data logger with a global positioning system and batteries. The system noise was approximately 0.2 pT √Hz- 1/2 in the 1-50 Hz frequency range. This performance was determined by including the thermal noise and the shielding effect of the copper shield, which covered the SQUID magnetometers to eliminate high-frequency interference. The temperature drift of the system was ˜0.8 pT °C- 1 in an FLL operation. The system operated for a month using 33 l liquid helium. Using this system, we performed the measurements of geomagnetic field in the open-air, far away from the city. The system could detect weak geomagnetic signals such as the Schumann resonance with sixth harmonics, and the ionospheric Alfvén resonance appearing at night, for the north-south and east-west components of the geomagnetic field. We confirm that the system was capable of high-sensitivity measurement of the weak geomagnetic activities.

  3. SQUIDs as detectors in a new experiment to measure the neutron electric dipole moment

    International Nuclear Information System (INIS)

    Espy, M.A.; Cooper, M.; Lamoreaux, S.; Kraus, R.H. Jr.; Matlachov, A.; Ruminer, P.

    1998-01-01

    A new experiment has been proposed at Los Alamos National Laboratory to measure the neutron electric dipole moment (EDM) to 4x10 -28 ecm, a factor of 250 times better than the current experimental limit. Such a measure of the neutron EDM would challenge the theories of supersymmetry and time reversal violation as the origin of the observed cosmological asymmetry in the ratio of baryons to antibaryons. One possible design for this new experiment includes the use of LTC SQUIDs coupled to large (∼100 cm 2 ) pick-up coils to measure the precision frequency of the spin-polarized 3 He atoms that act as polarizer, spin analyzer, detector, and magnetometer for the ultra-cold neutrons used in the experiment. The method of directly measuring the 3 He precession signal eliminates the need for very uniform magnetic fields (a major source of systematic error in these types of experiments). It is estimated that a flux of ∼2x10 -16 Tm 2 (0.1 Φ 0 ) will be coupled into the pick-up coils. To achieve the required signal-to-noise ratio one must have a flux resolution of dΦ SQ = 2x10 -6 Φ 0 /√Hz at 10 Hz. While this is close to the sensitivity available in commercial devices, the effects of coupling to such a large pick-up coil and flux noise from other sources in the experiment still need to be understood. To determine the feasibility of using SQUIDs in such an application the authors designed and built a superconducting test cell, which simulates major features of the proposed EDM experiment, and they developed a two-SQUID readout system that will reduce SQUID noise in the experiment. They present an overview of the EDM experiment with SQUIDs, estimations of required SQUID parameters and experimental considerations. The authors also present the measured performance of a single magnetometer in the test cell as well as the performance of the two SQUID readout technique

  4. Low-frequency noise in high-(Tc) superconductor Josephson junctions, SQUIDs, and magnetometers

    Science.gov (United States)

    Miklich, A. H.

    1994-05-01

    Design and performance of high-T(sub c) dc superconducting quantum interference devices (SQUID's), junctions that comprise them, and magnetometers made from them are described, with attention to sources of 1/f noise. Biepitaxial junctions are found to have large levels of critical current fluctuations which make them unsuitable for low-noise SQUID's; this suggests a poorly connected interface at the grain boundary junction. SQUID's from bicrystal junctions have levels of critical current noise controllable using bias current reversal techniques which leave the noise white down to frequencies of a few Hz. A SQUID with an energy resolution of 1.5 x 10(exp -30) J Hz(exp -1) at 1 Hz is reported. Magnetometers in which a (9 mm)(exp 2) pickup loop is directly coupled to a SQUID body have achieved field resolutions of 93 fT Hz(exp -1/2) down to frequencies below 1 Hz, improving to 39 fT Hz(exp -1/2) at 1 Hz with the addition of a 50mm-diameter single-turn flux transformer. Poor coupling to pickup loop makes it difficult to satisfy competing goals of high field resolution and small detector size necessary for multichannel biomagnetic imaging. Improved coupling is demonstrated by the use of multiturn-input-coil flux transformers, and a resolution of 35 fT Hz(exp -1/2) in the white noise region is reported with a (10 mm)(exp 2) pickup loop. However, additional 1/f noise from processed multilayer structures in the transformer limits the resolution at 1 Hz to 114 fT Hz(exp -1/2). High-T(sub c) SQUID's exhibit additional 1/f noise when cooled in a nonzero static magnetic field because of additional flux vortices trapped in the film, with the noise power at 1 Hz typically increasing by a factor of 10-20 in a field of 0.05mT (0.5 G). Finally, a SQUID-based voltmeter with a resolution of 9.2 pV Hz(exp -1/2) at 10 Hz (24 pV Hz(exp -1/2) at 1 Hz) is described.

  5. Low-Frequency Noise in High-T Superconductor Josephson Junctions, Squids, and Magnetometers.

    Science.gov (United States)

    Miklich, Andrew Hostetler

    The design and performance of high-T_ {rm c} dc superconducting quantum interference devices (SQUIDs), the junctions that comprise them, and magnetometers made from them are described, with special attention paid to sources of 1/f noise. Biepitaxial junctions are found to have large levels of critical current fluctuations which make them unsuitable for low-noise SQUIDs. This noise suggests a poorly connected interface at the grain boundary junction. SQUIDs from bicrystal junctions, in contrast, have levels of critical current noise that are controllable using bias current reversal techniques which leave the noise white down to frequencies of a few Hz. A SQUID with an energy resolution of 1.5times 10^{-30} J Hz^ {-1} at 1 Hz is reported. Magnetometers in which a (9 mm)^2 pickup loop is directly coupled to a SQUID body have achieved field resolutions of 93 fT Hz^{-1/2} down to frequencies below 1 Hz, improving to 39 fT Hz^{-1/2} at 1 Hz with the addition of a 50 mm-diameter single-turn flux transformer. Although the performance of these devices is sufficient for single -channel biomagnetometry or geophysical studies, their relatively poor coupling to the pickup loop makes it difficult to satisfy the competing goals of high field resolution and small detector size necessary for multichannel biomagnetic imaging. Improved coupling is demonstrated by the use of multiturn-input-coil flux transformers, and a resolution of 35 fT Hz^{-1/2} in the white noise region is reported with a (10 mm) ^2 pickup loop. However, additional 1/f noise from the processed multilayer structures in the transformer limits the resolution at 1 Hz to 114 fT Hz^ {-1/2}. High-T_{ rm c} SQUIDs are shown to exhibit additional 1/f noise when they are cooled in a nonzero static magnetic field because of the additional flux vortices trapped in the film, with the noise power at 1 Hz typically increasing by a factor of 10-20 in a field of 0.05 mT (0.5 G). Finally, a SQUID-based voltmeter with a resolution

  6. Classificação Internacional para a Prática de Enfermagem: instrumental tecnológico para a prática profissional Clasificación Internacional para la Práctica de Enfermería: intrumentral tecnológico para la práctica profesional International Classification for Nursing Practice: technological instrument for professional practice

    Directory of Open Access Journals (Sweden)

    Maria Miriam Lima da Nóbrega

    2009-10-01

    Full Text Available Considera-se o uso de tecnologias de informação como instrumentos que podem fazer com que a prática de enfermagem se torne visível no conjunto de dados de saúde, locais, nacionais e internacionais, de modo a influenciar na elaboração de políticas de saúde e de educação. Aborda-se o desenvolvimento dos sistemas de classificação em enfermagem, com ênfase na Classificação Internacional para a Prática de Enfermagem - CIPE®, como instrumental tecnológico para a prática profissional, que tem como um dos principais critérios para sua construção o de ser suficientemente ampla e sensível à diversidade cultural, de modo que sirva aos múltiplos propósitos requeridos pelos distintos países onde será utilizada.El uso de tecnologías de información es considerado como instrumentos que pueden hacer la práctica de enfermería visible en los datos de salud, local, nacional e internacionalmente, de manera a influir en la elaboración de políticas de salud y educación. Aborda-se el desarrollo de los sistemas de la clasificación en enfermería se aproxima, con énfasis en la Clasificación Internacional para la Práctica de Enfermería - CIPE®, cono instrumental tecnológico para la practica profesional, que tiene como uno de los criterios para su construcción el de ser suficientemente ancho y sensible a la diversidad cultural, para que sirva a los múltiplos propósitos requeridos por los diferentes países dónde se la usará.The use of information technologies are considered as instruments that can do that nursing practice becomes visible in health data, local, national and internationally, in way to influence the elaboration of health and education policies. The development of nursing classification systems is approached, with emphasis in the International Classification for Nursing Practice - ICNP®, with technological instrument for professional practice, which has as one of the principal criteria for its construction to be

  7. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  8. The biology and ecology of the jumbo squid Dosidicus gigas (Cephalopoda in Chilean waters: a review

    Directory of Open Access Journals (Sweden)

    Christian M Ibáñez

    2015-07-01

    Full Text Available ABSTRACT. The jumbo squid Dosidicus gigas is the most abundant cephalopod species in the southeastern Pacific Ocean, which supports the biggest cephalopod fishery in the world. Due to its growing economic importance, the population growth and distributional expansion of this squid is being increasingly studied. Nevertheless, some basic features of the biology of D. gigas are still unknown or have been poorly investigated. In this review we summarize the known information regarding the biology and ecology of this species in the southeastern Pacific Ocean; we focus on the Chilean region in order to propose hypotheses and research lines for a better understanding the life history of this organism. Available data on the size structure, reproduction and genetics of D. gigas allows us to propose hypotheses related to the squid's life history traits. Based on the current literature and publications of colleagues, we propose two hypotheses regarding the effect of spatial variation on the life history of D. gigas. Hypothesis 1: Squids mature at large sizes and spawn in oceanic waters with warm temperatures where paralarvae and juveniles develop. Immature squids migrate near shore to feed, grow and mature, and then return to the offshore sites to spawn. Hypothesis 2: Alternatively, juvenile D. gigas in the oceanic zone do not migrate to coastal waters and mature at small sizes compared to individuals living near the coast that mature at larger size and migrate to oceanic waters to spawn. We provide background information about the feeding behavior and parasitism of this species, suggesting that D. gigas is an important trophic link in the southeastern Pacific marine ecosystem. However, more studies on the feeding habits, reproduction and parasite load are needed not only to test hypotheses proposed in this study, but also to advance the overall knowledge of this species.

  9. Preparation and characterisation of irradiated crab chitosan and New Zealand Arrow squid pen chitosan

    International Nuclear Information System (INIS)

    Shavandi, Amin; Bekhit, Adnan A.; Bekhit, Alaa El-Din A.; Sun, Zhifa; Ali, M. Azam

    2015-01-01

    The properties of chitosan from Arrow squid (Nototodarus sloanii) pen (CHS) and commercial crab shell (CHC) were investigated using FTIR, DSC, SEM and XRD before and after irradiation at the dose of 28 kGy in the presence or absence of 5% water. Also, the viscosity, deacetylation degree, water and oil holding capacities, colour and antimicrobial activities of the chitosan samples were determined. Irradiation decreased (P < 0.05) the viscosity of CHC from 0.21 to 0.03 Pa s and of CHS from 1.71 to 0.23 Pa s. The inclusion of water had no effect on the viscosity of irradiated chitosan. Irradiation did not affect the degree of deacetylation of CHC, but increased the deacetylation degree of CHS from 72.78 to 82.29% in samples with 5% water. Water and oil holding capacities of CHS (1197.30% and 873.3%, respectively) were higher (P < 0.05) than those found in CHC (340.70% and 264.40%, respectively). The water and oil holding capacities were decreased for both types of chitosan irradiation, but were not affected by the addition of water. Squid pen chitosan was whiter in colour (White Index = 90.06%) compared to CHC (White Index = 83.70%). Generally, the CHC samples (control and irradiated) exhibited better antibacterial activity compared to CHS, but the opposite was observed with antifungal activity. - Highlights: • Chitosan prepared from Arrow squid pens (Nototodarus sloanii). • Chitosan samples were gamma irradiated at 28 kGy. • Squid pen chitosan showed high fat and water uptake capacities compared to crab shell chitosan. • Gamma irradiation enhanced the DDA of squid pen chitosan but not crab shell chitosan.

  10. Fishery biology of jumbo flying squid Dosidicus gigas off Costa Rica Dome

    Science.gov (United States)

    Chen, Xinjun; Li, Jianghua; Liu, Bilin; Li, Gang; Lu, Huajie

    2014-06-01

    The jumbo flying squid ( Dosidicus gigas) population was surveyed with the help of Chinese squid jigging vessels off the Costa Rica Dome (4°-11°N, 90°-100°W) in 2009 and 2010. The daily catch of D. gigas in the two survey cruises ranged from 0 to 5.5 t and was mostly obtained from the areas bounded by 6°-9°N and 91°-94°W and by 6°30'-7°30'N and 96°-97°W. The sea surface temperature in the areas yielding the most catch ranged from 27.5 to 29°C. The sex ratio of the total catch was 3.75:1 (female: male). The mantle length of the squid ranged from 211 to 355 mm (male) and from 204 to 429 mm (female) with an average of 297.9 and 306.7 mm, respectively. In the relationship of the mantle length (mm) and body weight (g) of the squid, there was no significant difference between sexes. The female and male were at a similar maturity, and most individuals are maturing or have matured with a few females being spent. The size (mantle length) and age at the first sexual maturity were 297 mm and 195 d in females, and less than 211 mm and 130 d in males, respectively. Most of the sampled stomachs (70.6%) had no food remains. The major preys of the squids were fish, cephalopods and crustaceans, with the most abundant Myctophum orientale and D. gigas. The preys in more than 65% of the non-empty sampled stomachs evidenced the cannibalism of D. gigas. The results improved current understanding of the fishery biology of D. gigas off the Costa Rica Dome, which may facilitate the assessment and management of relative fishery resources.

  11. Seismic instrumentation

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The aim of this RFS is to define the type, location and operating conditions for seismic instrumentation needed to determine promptly the seismic response of nuclear power plants features important to safety to permit comparison of such response with that used as the design basis

  12. Meteorological instrumentation

    International Nuclear Information System (INIS)

    1982-06-01

    RFS or ''Regles Fondamentales de Surete'' (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety , while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the ''Service Central de Surete des Installations Nucleaires'' or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The purpose of this RFS is to specify the meteorological instrumentation required at the site of each nuclear power plant equipped with at least one pressurized water reactor

  13. Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

    International Nuclear Information System (INIS)

    Chesca, Boris; John, Daniel; Mellor, Christopher J.

    2015-01-01

    A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S Φ 1/2 decreases as 1/N 1/2 . Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa 2 Cu 3 O 7 . Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S Φ 1/2 between (0.25 and 0.44) μΦ 0 /Hz 1/2 for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications

  14. The mechanics of locomotion in the squid Loligo pealei: locomotory function and unsteady hydrodynamics of the jet and intramantle pressure.

    Science.gov (United States)

    Anderson, E J; DeMont, M E

    2000-09-01

    High-speed, high-resolution digital video recordings of swimming squid (Loligo pealei) were acquired. These recordings were used to determine very accurate swimming kinematics, body deformations and mantle cavity volume. The time-varying squid profile was digitized automatically from the acquired swimming sequences. Mantle cavity volume flow rates were determined under the assumption of axisymmetry and the condition of incompressibility. The data were then used to calculate jet velocity, jet thrust and intramantle pressure, including unsteady effects. Because of the accurate measurements of volume flow rate, the standard use of estimated discharge coefficients was avoided. Equations for jet and whole-cycle propulsive efficiency were developed, including a general equation incorporating unsteady effects. Squid were observed to eject up to 94 % of their intramantle working fluid at relatively high swimming speeds. As a result, the standard use of the so-called large-reservoir approximation in the determination of intramantle pressure by the Bernoulli equation leads to significant errors in calculating intramantle pressure from jet velocity and vice versa. The failure of this approximation in squid locomotion also implies that pressure variation throughout the mantle cannot be ignored. In addition, the unsteady terms of the Bernoulli equation and the momentum equation proved to be significant to the determination of intramantle pressure and jet thrust. Equations of propulsive efficiency derived for squid did not resemble Froude efficiency. Instead, they resembled the equation of rocket motor propulsive efficiency. The Froude equation was found to underestimate the propulsive efficiency of the jet period of the squid locomotory cycle and to overestimate whole-cycle propulsive efficiency when compared with efficiencies calculated from equations derived with the squid locomotory apparatus in mind. The equations for squid propulsive efficiency reveal that the refill

  15. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  16. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  17. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  18. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  19. Influence of gamma irradiation and low temperature storage on the quality and shelf life of squid (Doryteuthis sibogae

    Directory of Open Access Journals (Sweden)

    Manjanaik, B.

    2017-08-01

    Full Text Available Irradiation is considered as an efficient method for the reduction of microorganisms in food. It has been used to improve the safety and shelf life of food products. The present investigation is aimed at studying the influence of gamma irradiation (3 and 5 kGy and subsequent storage at refrigeration temperature (4oC on the chemical, microbial qualities and extended shelf life of squid (Doryteuthis sibogae. The total volatile base nitrogen (TVB-N and trimethyl amine nitrogen values (TMA-N of the irradiated squid samples significantly decreased in comparison with the control (non-irradiated stored at 4oC. The thiobarbituric acid values for the irradiated squid was significantly lower than of the non-irradiated samples stored at 4oC (p<0.05. The pH value of the squid was affected significantly by both, irradiation dose and storage temperature (p<0.05. The total microbial load for the non-irradiated squid samples was higher than those of irradiated samples at 4oC temperature. The results revealed that the combination of irradiation and refrigerated storage resulted in a significant reduction of microbial growth and stabilized the biochemical characteristics of squid.

  20. Studies on the effect of low dose gamma irradiation on the chemical, microbial quality and shelf life of squid

    International Nuclear Information System (INIS)

    Bojayanaik, Manjanaik; Naroth, Kavya; Shetty, Veena; Hiriyur, Somashekarappa

    2014-01-01

    The present investigation was carried out to study the combined effect of low dose gamma irradiation (1, 3 and 5 kGy) and storage at refrigeration (+4℃) and frozen (-18℃) temperatures, on the shelf life extension of fresh squid. The study was based on microbiological and physico-chemical changes occurring in the squid samples. The biochemical parameters such as total volatile base nitrogen and trimethyl amine nitrogen values for irradiated squid samples were significantly lower than non-irradiated samples at both storage temperatures and the rate of decrease was more pronounced in samples irradiated at the higher dose of 3 and 5 kGy (p<0.05). pH values of squid samples were affected by both irradiation dose and storage temperature (p<0.05). Total microbial load for non- irradiated (control) squid samples were higher than the respective irradiated samples at both storage temperatures. The results revealed that the combination of irradiation and low temperature storage resulted in a significant reduction of microbial growth and extend the shelf life of squid at refrigeration and frozen temperature to about 12 and 90 days respectively. (author)

  1. Natural mortality estimation and rational exploitation of purpleback flying squid Sthenoteuthis oualaniensis in the southern South China Sea

    Science.gov (United States)

    Wang, Xuehui; Qiu, Yongsong; Zhang, Peng; Du, Feiyan

    2017-07-01

    Based on the biological data of purpleback flying squid ( Sthenoteuthis oualaniensis) collected by light falling-net in the southern South China Sea (SCS) during September to October 2012 and March to April 2013, growth and mortality of `Medium' and `Dwarf' forms of squid are derived using the Powell-Wetherall, ELEFAN methods and length-converted catch curves (FiSAT package). Given a lack of commercial exploitation, we assume total mortality to be due entirely to natural mortality. We estimate these squid have fast growth, with growth coefficients ( k) ranging from 1.42 to 2.39, and high natural mortality ( M), with estimates ranging from 1.61 to 2.92. To sustainably exploit these squid stocks, yield per recruitment based on growth and natural mortality was determined using the Beverton-Holt dynamic pool model. We demonstrate squid stocks could sustain high fishing mortality and low ages at first capture, with an optimal fishing mortality >3.0, with the optimal age at first capture increased to 0.4-0.6 years when fishing mortality approached optimal levels. On the basis of our analyses and estimates of stock biomass, we believe considerable potential exists to expand the squid fishery into the open SCS, relieving fishing pressure on coastal waters.

  2. Ultra-sensitive sensors for weak electromagnetic fields using high-Tc SQUIDS for biomagnetism, NDE, and corrosion currents

    International Nuclear Information System (INIS)

    Kraus, R.H. Jr.; Flynn, E.R.; Espy, M.; Jia, Q.X.; Wu, X.D.; Reagor, D.

    1998-01-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The research has directly contributed to a new DOE supported project, three patents (one granted and two submitted), and several potential opportunities for new program funding at the Laboratory. The authors report significant developments extending from basic understanding of and fabrication techniques for high critical-temperature (high-T c ) SQUID devices to the development of high-level applications such as the SQUID Microscope. The development of ramp edge geometry and silver-doped YBa 2 Cu 3 O 7-x (YBCO) electrodes has tremendously improved the performance of high-T c SQUIDS. Recent experiments have proven and quantified the LANL-patented superconducting imaging plane gradiometry concept. A SQUID microscope, developed largely under this project, has recently acquired data that demonstrated exceptional sensitivity and resolution. New techniques for background noise suppression, needed to use the extraordinarily sensitive SQUID sensors in unshielded environments, have also been developed. Finally, initial investigations to use SQUIDs in a basic physics experiment to measure the electric dipole moment of the neutron were very successful

  3. A comparison of RANZCR and Singapore-designed radiation oncology practice audit instruments: how does reproducibility affect future approaches to revalidation

    International Nuclear Information System (INIS)

    Lu, Jiade J.; Wynne, Christopher J.; Kumar, Mahesh B.; Shakespeare, Thomas P.; Mukherjee, Rahul; Back, Michael F.

    2004-01-01

    Physician competency assessment requires the use of validated methods and instruments. The Royal Australian and New Zealand College of Radiologists (RANZCR) developed a draft audit form to be evaluated as a competency assessment instrument for radiation oncologists (ROs) in Australasia. We evaluated the reliability of the RANZCR instrument as well as a separate The Cancer Institute (TCI) Singapore-designed instrument by having two ROs perform an independent chart review of 80 randomly selected patients seen at The Cancer Institute (TCI), Singapore. Both RANZCR and TCI Singapore instruments were used to score each chart. Inter- and intra-observer reliability for both audit instruments were compared using misclassification rates as the primary end-point. Overall, for inter-observer reproducibility, 2.3% of TCI Singapore items were misclassified compared to 22.3% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less inter-observer misclassification). For intra-observer reproducibility, 2.4% of TCI Singapore items were misclassified compared to 13.6% of RANZCR items (P < 0.0001, 100.00% confidence that TCI instrument has less intra-observer misclassification). The proposed RANZCR RO revalidation audit instrument requires further refinement to improve validity. Several items require modification or removal because of lack of reliability, whereas inclusion of other important and reproducible items can be incorporated as demonstrated by the TCI Singapore instrument. The TCI Singapore instrument also has the advantage of incorporating a simple scoring system and criticality index to allow discrimination between ROs and comparisons against future College standards Copyright (2004) Blackwell Publishing Asia Pty Ltd

  4. Recruitment Practices, a Socially accepted Instrument of Domination Prácticas de selección de personal, un instrumento de dominación socialmente aceptado

    Directory of Open Access Journals (Sweden)

    Yenny Hernández Sánchez

    2009-06-01

    Full Text Available The main focus of the investigation from which this article is derived, is to question the recruitment practices as a power device, which means trying to unveiling them as socially accepted instruments of domination that end up in abuses on the participating candidates. These processes, which are part of the human management and administrative duties, are questioned from a hermeneutic perspective, which have its foundations rooted in psychology from where it takes some not contextualized tools. The work is presented synthetically and outlines some final thoughts, not without first addressing some theories from authors that allow in some cases, contextualizing the problem, and in others, sustaining the ethical position which is reflected in this written, establishing intercommunication with some philosophers, being the most important to the analysis: Follett, Weber, Foucault and Deleuze.El objetivo central de la investigación de la cual se deriva el artículo, es interrogar las prácticas de selección de personal en tanto dispositivo de poder, es decir, se pretende develarlas como instrumentos de dominación socialmente aceptados, con los cuales se incurre en abusos sobre los candidatos participantes. Estos procesos –que hacen parte de la gestión humana y el quehacer administrativo- se cuestionan desde una perspectiva hermenéutica, los cuales tienen sus fundamentos arraigados en la Psicología, de donde toma algunas herramientas con un uso descontextualizado. El trabajo realizado se presenta sintéticamente y se esbozan algunas consideraciones finales, no sin antes abordar algunas teorías de autores que permiten poner en contexto el problema, en algunos casos, y sustentar la postura ética que se trasluce en el escrito, en otros, de suerte que se establece una intercomunicación con teóricos siendo los más relevantes en el análisis: Follet, Weber, Foucault y Deleuze. 

  5. Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

    Science.gov (United States)

    Campbell, W. H.; Zimmerman, J. E.

    1979-01-01

    The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

  6. Polarization sensitivity and retinal topography of the striped pyjama squid (Sepioloidea lineolata - Quoy/Gaimard 1832).

    Science.gov (United States)

    Talbot, Christopher M; Marshall, Justin

    2010-10-01

    Coleoid cephalopods (octopus, cuttlefish and squid) potentially possess polarization sensitivity (PS) based on photoreceptor structure, but this idea has rarely been tested behaviourally. Here, we use a polarized, striped optokinetic stimulus to demonstrate PS in the striped pyjama squid, Sepioloidea lineolata. This species displayed strong, consistent optokinetic nystagmic eye movements in response to a drum with stripes producing e-vectors set to 0 deg, 45 deg, 90 deg and 135 deg that would only be visible to an animal with PS. This is the first behavioural demonstration of a polarized optokinetic response in any species of cephalopod. This species, which typically sits beneath the substrate surface looking upwards for potential predators and prey, possesses a dorsally shifted horizontal pupil slit. Accordingly, it was found to possess a horizontal strip of high-density photoreceptors shifted ventrally in the retina, suggesting modifications such as a change in sensitivity or resolution to the dorsal visual field.

  7. High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment

    International Nuclear Information System (INIS)

    Liao, S H; Hsu, S C; Lin, C C; Horng, H E; Chen, J C; Chen, M J; Wu, C H; Yang, H C

    2003-01-01

    We set up an electronic gradiometer for magnetocardiography (MCG) in an unshielded environment. The electronically balanced gradiometer consists of high-temperature radio-frequency superconducting quantum interference device (rf SQUID) magnetometers. The rf SQUID magnetometers are arranged to form the electronic first-order, four-vector gradiometer, or second-order gradiometer. The output of the MCG signal was filtered by a band pass (1-30 Hz) and power line filters. We can reduce the noise to ∼1 pT Hz -1/2 at 1 Hz for second-order or four-vector gradiometers. Two-dimensional MCG imaging is demonstrated. The results are discussed with data measured in the moderate magnetically shielded environment

  8. Habitat and distribution of post-recruit life stages of the squid Loligo forbesii

    Science.gov (United States)

    Smith, Jennifer M.; Macleod, Colin D.; Valavanis, Vasilis; Hastie, Lee; Valinassab, Tooraj; Bailey, Nick; Santos, M. Begoña; Pierce, Graham J.

    2013-10-01

    This study models habitat preferences of the squid Loligo forbesii through its post-recruitment life cycle in waters around Scotland (UK). Trawl survey and market sample data from 1985 to 2004 are used to model seasonal habitats of immature, maturing and mature squid (maturity being inferred from size and season). Squid presence-absence and catch rate in areas of presence were analysed using generalised additive models, relating spatiotemporal patterns of distribution and abundance to ecogeographic variables. For all maturity classes, higher abundance in winter and spring (i.e., quarters 1 and 2) was associated with deeper water while higher abundance in summer and autumn (quarters 3 and 4) was associated with shallower water, consistent with seasonal onshore-offshore migrations but suggesting that most spawning may take place in deeper waters. The preferred SST range was generally 8-8.75 °C while preferred salinity values were below 35‰ in winter and summer and above 35‰ in spring and autumn. Squid were positively associated with gravel substrate and negatively associated with mud. Seasonal changes in habitat use were more clearly evident than changes related to inferred maturity, although the two effects cannot be fully separated due to the annual life cycle. Habitat selection for this species can be satisfactorily modelled on a seasonal basis; predictions based on such models could be useful for fishers to target the species more effectively, and could assist managers wishing to protect spawning grounds. The extent to which this approach may be useful for other cephalopods is discussed.

  9. Ultra-Low Field SQUID-NMR using LN2 Cooled Cu Polarizing Field coil

    Science.gov (United States)

    Demachi, K.; Kawagoe, S.; Ariyoshi, S.; Tanaka, S.

    2017-07-01

    We are developing an Ultra-Low Field (ULF) Magnetic Resonance Imaging (MRI) system using a High-Temperature Superconductor superconducting quantum interference device (HTS rf-SQUID) for food inspection. The advantages of the ULF-NMR (Nuclear Magnetic Resonance) / MRI as compared with a conventional high field MRI are that they are compact and of low cost. In this study, we developed a ULF SQUID-NMR system using a polarizing coil to measure fat of which relaxation time T1 is shorter. The handmade polarizing coil was cooled by liquid nitrogen to reduce the resistance and accordingly increase the allowable current. The measured decay time of the polarizing field was 40 ms. The measurement system consisted of the liquid nitrogen cooled polarizing coil, a SQUID, a Cu wound flux transformer, a measurement field coil for the field of 47 μT, and an AC pulse coil for a 90°pulse field. The NMR measurements were performed in a magnetically shielded room to reduce the environmental magnetic field. The size of the sample was ϕ35 mm × L80 mm. After applying a polarizing field and a 90°pulse, an NMR signal was detected by the SQUID through the flux transformer. As a result, the NMR spectra of fat samples were obtained at 2.0 kHz corresponding to the measurement field Bm of 47 μT. The T1 relaxation time of the mineral oil measured in Bm was 45 ms. These results suggested that the ULF-NMR/MRI system has potential for food inspection.

  10. Limits to the observation of coherent oscillations in a SQUID ring

    International Nuclear Information System (INIS)

    Diggins, J.

    1995-01-01

    Using the quantum mechanical, lumped component model of a SQUID ring we compute the onset of tunnelling and macroscopic superposition behaviour in the parameter space of the ring. In addition, we make a quantitative estimate of the stability required in the environmental flux to sustain a superposition state. Both these features are of crucial importance to the realisation of experiments aimed at revealing such behaviour. (orig.)

  11. Sneaker Male Squid Produce Long-lived Spermatozoa by Modulating Their Energy Metabolism

    OpenAIRE

    Hirohashi, Noritaka; Tamura-Nakano, Miwa; Nakaya, Fumio; Iida, Tomohiro; Iwata, Yoko

    2016-01-01

    Spermatozoa released by males should remain viable until fertilization. Hence, sperm longevity is governed by intrinsic and environmental factors in accordance with the male mating strategy. However, whether intraspecific variation of insemination modes can impact sperm longevity remains to be elucidated. In the squid Heterololigo bleekeri, male dimorphism (consort and sneaker) is linked to two discontinuous insemination modes that differ in place and time. Notably, only sneaker male spermato...

  12. K+/Na+-triggered bioluminescence in the oceanic squid Symplectoteuthis oualaniensis

    OpenAIRE

    Tsuji, Frederick I.; Leisman, Gary B.

    1981-01-01

    A distinctive type of luminescent system present in the large dorsal luminous organ of the oceanic squid Symplectoteuthis oualaniensis is described. The organ produces an intense blue flash of light followed by a rapid decay in light intensity. Luminescence originates from numerous oval granules present in the luminous organ. The essential light-emitting components are membrane bound. Intact granules or washed homogenates of the granules are triggered to emit light by monovalent cations such ...

  13. Halide peroxidase in tissues that interact with bacteria in the host squid Euprymna scolopes.

    Science.gov (United States)

    Small, A L; McFall-Ngai, M J

    1999-03-15

    An enzyme with similarities to myeloperoxidase, the antimicrobial halide peroxidase in mammalian neutrophils, occurs abundantly in the light organ tissue of Euprymna scolopes, a squid that maintains a beneficial association with the luminous bacterium Vibrio fischeri. Using three independent assays typically applied to the analysis of halide peroxidase enzymes, we directly compared the activity of the squid enzyme with that of human myeloperoxidase. One of these methods, the diethanolamine assay, confirmed that the squid peroxidase requires halide ions for its activity. The identification of a halide peroxidase in a cooperative bacterial association suggested that this type of enzyme can function not only to control pathogens, but also to modulate the interactions of host animals with their beneficial partners. To determine whether the squid peroxidase functions under both circumstances, we examined its distribution in a variety of host tissues, including those that typically interact with bacteria and those that do not. Tissues interacting with bacteria included those that have specific cooperative associations with bacteria (i.e., the light organ and accessory nidamental gland) and those that have transient nonspecific interactions with bacteria (i.e., the gills, which clear the cephalopod circulatory system of invading microorganisms). These bacteria-associated tissues were compared with the eye, digestive gland, white body, and ink-producing tissues, which do not typically interact directly with bacteria. Peroxidase enzyme assays, immunocytochemical localization, and DNA-RNA hybridizations showed that the halide-dependent peroxidase is consistently expressed in high concentration in tissues that interact bacteria. Elevated levels of the peroxidase were also found in the ink-producing tissues, which are known to have enzymatic pathways associated with antimicrobial activity. Taken together, these data suggest that the host uses a common biochemical response to

  14. Depressed light emission by symbiotic Vibrio fischeri of the sepiolid squid Euprymna scolopes.

    OpenAIRE

    Boettcher, K J; Ruby, E G

    1990-01-01

    Bioluminescent marine bacteria of the species Vibrio fischeri are the specific light organ symbionts of the sepiolid squid Euprymna scolopes. Although they share morphological and physiological characteristics with other strains of V. fischeri, when cultured away from the light organ association the E. scolopes symbionts depress their maximal luminescence over 1,000-fold. The primary cause of this reduced luminescence is the underproduction by these bacteria of luciferase autoinducer, a molec...

  15. Phylogeographical patterns among Mediterranean sepiolid squids and their Vibrio symbionts: environment drives specificity among sympatric species.

    Science.gov (United States)

    Zamborsky, D J; Nishiguchi, M K

    2011-01-01

    Bobtail squid from the genera Sepiola and Rondeletiola (Cephalopoda: Sepiolidae) form mutualistic associations with luminous Gram-negative bacteria (Gammaproteobacteria: Vibrionaceae) from the genera Vibrio and Photobacterium. Symbiotic bacteria proliferate inside a bilobed light organ until they are actively expelled by the host into the surrounding environment on a diel basis. This event results in a dynamic symbiont population with the potential to establish the symbiosis with newly hatched sterile (axenic) juvenile sepiolids. In this study, we examined the genetic diversity found in populations of sympatric sepiolid squid species and their symbionts by the use of nested clade analysis with multiple gene analyses. Variation found in the distribution of different species of symbiotic bacteria suggests a strong influence of abiotic factors in the local environment, affecting bacterial distribution among sympatric populations of hosts. These abiotic factors include temperature differences incurred by a shallow thermocline, as well as a lack of strong coastal water movement accompanied by seasonal temperature changes in overlapping niches. Host populations are stable and do not appear to have a significant role in the formation of symbiont populations relative to their distribution across the Mediterranean Sea. Additionally, all squid species examined (Sepiola affinis, S. robusta, S. ligulata, S. intermedia, and Rondeletiola minor) are genetically distinct from one another regardless of location and demonstrate very little intraspecific variation within species. These findings suggest that physical boundaries and distance in relation to population size, and not host specificity, are important factors in limiting or defining gene flow within sympatric marine squids and their associated bacterial symbionts in the Mediterranean Sea.

  16. Pediatric patient-reported outcome instruments for research to support medical product labeling: report of the ISPOR PRO good research practices for the assessment of children and adolescents task force.

    Science.gov (United States)

    Matza, Louis S; Patrick, Donald L; Riley, Anne W; Alexander, John J; Rajmil, Luis; Pleil, Andreas M; Bullinger, Monika

    2013-06-01

    Patient-reported outcome (PRO) instruments for children and adolescents are often included in clinical trials with the intention of collecting data to support claims in a medical product label. The purpose of the current task force report is to recommend good practices for pediatric PRO research that is conducted to inform regulatory decision making and support claims made in medical product labeling. The recommendations are based on the consensus of an interdisciplinary group of researchers who were assembled for a task force associated with the International Society for Pharmacoeconomics and Outcomes Research (ISPOR). In those areas in which supporting evidence is limited or in which general principles may not apply to every situation, this task force report identifies factors to consider when making decisions about the design and use of pediatric PRO instruments, while highlighting issues that require further research. Five good research practices are discussed: 1) Consider developmental differences and determine age-based criteria for PRO administration: Four age groups are discussed on the basis of previous research (<5 years old, 5-7 years, 8-11 years, and 12-18 years). These age groups are recommended as a starting point when making decisions, but they will not fit all PRO instruments or the developmental stage of every child. Specific age ranges should be determined individually for each population and PRO instrument. 2) Establish content validity of pediatric PRO instruments: This section discusses the advantages of using children as content experts, as well as strategies for concept elicitation and cognitive interviews with children. 3) Determine whether an informant-reported outcome instrument is necessary: The distinction between two types of informant-reported measures (proxy vs. observational) is discussed, and recommendations are provided. 4) Ensure that the instrument is designed and formatted appropriately for the target age group. Factors to

  17. Electronics for a Next-Generation SQUID-Based Time-Domain Multiplexing System

    International Nuclear Information System (INIS)

    Reintsema, C. D.; Doriese, W. R.; Hilton, G. C.; Irwin, K. D.; Krinsky, J. W.; Adams, J. S.; Baker, R.; Bandler, S. R.; Kelly, R. L.; Kilbourne, C. A.; Porter, F. S.; Figueroa-Feliciano, E.; Wikus, P.

    2009-01-01

    A decade has elapsed since the design, development and realization of a SQUID-based time-division multiplexer at NIST. During this time the system has been used extensively for low-temperature-detector-array measurements. Concurrently, there have been substantial advancements both in detector array and commercial electronic component technology. The relevance and applicability of the technology has blossomed as well, often accompanied by more demanding measurement requirements. These factors have motivated a complete redesign of the NIST room-temperature read-out electronics. The redesign has leveraged advancements in component technology to achieve new capabilities better suited to the SQUID multiplexers and detector arrays being realized today. As examples of specific performance enhancements, the overall system bandwidth has been increased by a factor of four (a row switching rate of 6.24 MHz), the compactness has been increased by over a factor of two (a higher number of detector columns and rows per circuit board), and there are two high speed outputs per column (allowing fast switching of SQUID offsets in addition to digital feedback). The system architecture, design implementations, and performance advantages of the new system will be discussed. As an application example, the science chain flight electronics for the Micro-X High Resolution Microcalorimeter X-ray Imaging Rocket will be described as both a motivation for, and a direct implementation of the new system.

  18. SQUID Based Cryogenic Current Comparator for Measurements of the Dark Current of Superconducting Cavities

    CERN Document Server

    Vodel, W; Neubert, R; Nietzsche, S

    2005-01-01

    This contribution presents a LTS-SQUID based Cryogenic Current Comparator (CCC) for detecting dark currents, generated e.g. by superconducting cavities for the upcoming X-FEL project at DESY. To achieve the maximum possible energy the gradients of the superconducting RF cavities should be pushed close to the physical limit of 50 MV/m. The measurement of the undesired field emission of electrons (the so-called dark current) in correlation with the gradient will give a proper value to compare and classify the cavities. The main component of the CCC is a high performance LTS-DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the extracted dark current. For this reason the input coil of the SQUID is connected across a special designed toroidal niobium pick-up coil (inner diameter: about 100 mm) for the passing electron beam. A noise limited current resolution of nearly 2 pA/√(Hz) with a measurement bandwidth of up to 70 kHz was achieved without the pick-up coil. Now, ...

  19. HTS-SQUID NDE Technique for Pipes based on Ultrasonic Guided Wave

    International Nuclear Information System (INIS)

    Hatsukade, Y; Masutani, N; Teranishi, S; Masamoto, K; Kanenaga, S; Adachi, S; Tanabe, K

    2017-01-01

    This article describes research on the novel high-temperature superconductor (HTS) superconducting quantum interference device (SQUID) non-destructive evaluation (NDE) technique for metallic pipes based on ultrasonic guided waves. We constructed HTS-SQUID NDE system for pipes based on ultrasonic guided waves, which were generated and received by means of the magnetostrictive effects. Using the system, we measured magnetic signals due to T (0, 1) mode ultrasonic guided waves that transmitted on aluminium pipe, and investigated influences of measurement parameters to the magnetic signals, such as direction of a HTS-SQUID gradiometer, lift-off distance, and intensity and frequency of input current fed to a magnetostrictive transmitter. With the gradiometer oriented parallel to the pipe axis, more than 10 times larger signals were measured compared with that oriented perpendicular to the pipe axis. Magnetic signals measured by the gradiometer were inverse proportional to the power of the list- off distance, and proportional to the intensity of the input current up to 1 A pp . Relation between the frequency of the input current and the measured signal was shown and discussed. (paper)

  20. Optimization of a digital SQUID magnetometer in terms of noise and distortion

    International Nuclear Information System (INIS)

    Haverkamp, I; Toepfer, H; Wetzstein, O; Kunert, J; Stolz, R; Meyer, H-G; Ortlepp, T

    2012-01-01

    The digital SQUID magnetometer takes advantage of flux quantization in a superconducting loop in order to measure magnetic fields. The core element of the digital SQUID is a Josephson comparator with a superconducting antenna loop attached to one of its junctions. Evaluation of the circuit from the system’s point of view requires an analysis in the frequency domain. In order to obtain a high-resolution fast Fourier transform, large datasets are necessary which are difficult to generate with transient simulation tools. In this work we derive a behavioural model for the digital SQUID in order to overcome restrictions imposed by transient simulation. By means of this model the influence of the comparator grey zone and the input loop inductance on the system performance was analysed. In order to assess the system, evaluation criteria based on the power spectral density were applied, which are commonly used for characterization of semiconductor analogue to digital converters. As a result of this study, design guidelines for an optimum antenna inductance depending on the comparator grey zone are derived, allowing us to achieve an optimum system performance in terms of noise and distortion. (paper)

  1. Spawning pattern of the neon flying squid Ommastrephes bartramii (Cephalopoda: Oegopsida around the Hawaiian Islands

    Directory of Open Access Journals (Sweden)

    Dharmamony Vijai

    2014-12-01

    Full Text Available The neon flying squid, Ommastrephes bartramii, is an oceanic squid species that is widely distributed in the North Pacific, with the winter-spring cohort spawning around the Hawaiian Islands. Here, we investigated the spawning characteristics of O. bartramii by analyzing various reproductive parameters of individuals (622 males, 108 females collected in this region. Female spawning status was determined from the somatic indices and histological characteristics of the ovaries. At all developmental stages, the ovaries of spawned females contained oocytes, and oviduct fullness was not correlated with body size. Thus, because the eggs mature asynchronously, with multiple filling and evacuation events, this species is considered an intermittent spawner. Mature males with developed accessory glands were also present within the distribution range of healthy spawned females, indicating that mating occurs between spawning events. Our data indicate that the first spawning event occurs at a mantle length of ~520-540 mm for Hawaiian O. bartramii. Subsequently, the squid forage and grow, and refill the oviducts, before the second spawning event occurs.

  2. Specific accumulation of polychlorinated biphenyls and organochlorine pesticides in Japanese common squid as a bioindicator

    International Nuclear Information System (INIS)

    Ueno, D.; Inoue, S.; Ikeda, K.; Tanaka, H.; Yamada, H.; Tanabe, S.

    2003-01-01

    Japanese common squid is a suitable bioindicator for monitoring organochlorines pollution in waters around Japan. - Organochlorines (OCs) representing Persistent Organic Pollutants (POPs) such as PCBs (polychlorinated biphenyls), DDTs (DDT and its metabolites), CHLs (chlordane compounds), HCHs (hexachlorocyclohexane isomers) and HCB (hexachlorobenzene) were determined in the liver of Japanese common squid (Todarodes pacificus) collected from the waters around Japan (Japan Sea and western North Pacific Ocean). Among OCs concentrations, PCBs (upto 5600 ng/g lipid wt.) were the highest, and those of other OCs were in the order of DDT> CHLs > HCHs > HCB. Studies on growth trend and seasonal variation of OCs in this species suggest a rapid reflection of the pollution levels in seawater where and when they were collected, regardless of body-length and time of collection. These results indicate that Japanese common squid is a suitable bioindicator for monitoring OCs pollution in waters around Japan. With regard to the geographical distribution of OCs in this species collected from waters around Japan, OCs concentrations in specimens from Japan Sea were higher than those from the Pacific Ocean. This result might reflect some existing of local pollution sources of OCs around Japan Sea, and slower water exchange between Japan Sea and open ocean

  3. SQUID magnetometry and magneto-optics of epitaxial EuS

    International Nuclear Information System (INIS)

    Rumpf, K.; Granitzer, P.; Krenn, H.; Kellner, W.; Pascher, H.; Kirchschlager, R.; Janecek, S.

    2004-01-01

    The complicated (H,T)-magnetic phase diagram of EuS is caused by the critical balance between nearest and next nearest neighbour exchange interaction (J NN = 0.119 K and J NNN =-0.1209 K) and leads to various spin arrangements NNSS..., NSN..., NNS, NNN... [NS denotes opposite ferromagnetic order in adjacent (111) planes]. Beside the subtle local exchange of 5d-t 2g electrons and localized holes with neighbouring Eu-4f spins, obviously also the strain status influences the occurrence of these different phases. We investigate the magnetic ordering phenomenon in a strained 2.5 μm EuS film on BaF 2 substrate by SQUID magnetometry and magneto-optics like spectral Faraday- and Kerr-effect measurements for temperatures from 2 K up to 200 K and for magnetic field up to 5 T. The magneto-optical probe monitors the local environment of the photoexcited electron-hole pair, called magnetic exciton, located within a ferromagnetic surrounding (photoinduced magnetic polaron), whereas the integral magnetization measured by SQUID is most sensitive to long-range magnetic ordering. In spite of the dissimilarity of measurement techniques we find an influence of the long-range magnetic order (e.g. of the NNS- or NNN-matrix) on the non-resonant Kerr reflection. The complementarity of SQUID and magneto-optical methods is stringent only in the (resonant) spectral range, where magnetic polarons are formed. (author)

  4. Growth and optical development of the ocular lens of the squid (Sepioteuthis lessoniana).

    Science.gov (United States)

    Sivak, J G; West, J A; Campbell, M C

    1994-09-01

    Lens focal properties (spherical aberration), diameter and relative anterior/posterior proportions were measured photographically for Japanese squid (Sepioteuthis lessoniana) at ages 4-6 weeks, 7-9 weeks and 7-8 months. The measures involved photographing the refractive effects of lenses in a physiological solution, with and without an index matching fluid (polyvinylpyrroloidone solution), on a parallel array of fine helium-neon laser beams. Spherical aberration was determined from measurement of back vertex distance. Similar measurements were made on lenses from the eyes of cuttlefish (Sepia officinalis). The cephalopod lens develops as hemispheric halves from separate ectodermal sources. The posterior component contributes, on average, about 60% of axial lens diameter in S. lessoniana of all ages and 55% in S. officinalis. However, these proportions vary widely in both species. All lenses of both species show that spherical aberration is neutralized, although small variations in back vertex distance (positive and negative spherical aberration) were measured. Preliminary measures indicate that the refractive index distribution within the cephalopod lens varies in a manner reminiscent of teleost lenses. Squid lenses from animals 7-9 weeks of age were optimally corrected for spherical aberration. Some squid of this age, from a separate tank, showed a high incidence of cataract development. In each case, lens opacification was caused by deterioration of the posterior lens component.

  5. Assessment of Heavy Metal Contamination in Squid (Loligo Spp.) Tissues of Kedah-Perlis Waters, Malaysia

    International Nuclear Information System (INIS)

    Jamil, T.; Lias, K.; Norsila, D.; Syafinaz, N.S.

    2014-01-01

    This study was carried out to determine the concentration of selected heavy metals (Cd, Cu, Pb and Zn) in three different tissues collected from the ink-sac, head, and muscle of the squid. Squid samples were caught off the coastal waters of Kedah-Perlis, where only mature squids within the maturity size-range of 13 to 15 cm were used. From this study, the concentration of Zn (35.06 ± 4.06 mg/ kg in dry weight) was found significantly higher in all of the tissues, followed by Cu (15.10 ± 13.28 mg/ kg in dry weight), Cd (4.76 ± 3.77 mg/ kg in dry weight), and Pb with an average value of 4.01 ± 0.08 mg/ kg in dry weight. From this study, it was discovered that Zn and Cu concentrations in the tissues were lower than the maximum limit recommended by the Food and Agriculture Organization, Malaysian Food Regulation (1985), as well as other countries. Meanwhile, both non-essential elements namely Cd and Pb recorded higher values than that of the recommended concentrations. According to the Metal Pollution Index (MPI), the ink-sac indicated medium-range contamination, while the head and muscle tissues showed low contamination levels. (author)

  6. Hypoxia tolerance and antioxidant defense system of juvenile jumbo squids in oxygen minimum zones

    Science.gov (United States)

    Trübenbach, Katja; Teixeira, Tatiana; Diniz, Mário; Rosa, Rui

    2013-10-01

    Jumbo squid (Dosidicus gigas) is a large oceanic squid endemic off the Eastern Tropical Pacific that undertakes diel vertical migrations into mesopelagic oxygen minimum zones. One of the expected physiological effects of such migration is the generation of reactive oxygen species (ROS) at the surface, promoted by the transition between hypoxia and reoxygenation states. The aim of this study was to investigate the energy expenditure rates and the antioxidant stress strategies of juvenile D. gigas under normoxia and hypoxia, namely by quantifying oxygen consumption rates, antioxidant enzyme activities [including superoxide dismutase (SOD), catalase (CAT) and glutathione-S-transferase (GST)], heat shock protein expression (Hsp70/Hsc70), and lipid peroxidation [malondialdehyde (MDA) levels]. A high significant decrease (68%) in squid's metabolic rates was observed during hypoxia (p0.05), with the latter indicating no enhancement of lipid peroxidation (i.e. cellular damage) at the warmer and normoxic surface waters. The understanding of such physiological strategies that are linked to oxygen deprivation and reoxygenation phases may provide valuable information about how this species is quickly responding to the impacts of environmental stressors coupled with global climate change.

  7. Preparation and evaluation of squid ink polysaccharide-chitosan as a wound-healing sponge.

    Science.gov (United States)

    Huang, Na; Lin, Jiali; Li, Sidong; Deng, Yifeng; Kong, Songzhi; Hong, Pengzhi; Yang, Ping; Liao, Mingneng; Hu, Zhang

    2018-01-01

    A new type of wound healing agent was developed using two marine biomaterials (squid ink polysaccharide and chitosan) as carriers and calcium chloride as an initiator for coagulation. Based on central composite design-response surface methodology, comprehensive evaluation of appearance quality for composite sponges and water absorbency were used as evaluation indices to identify the optimized preparation conditions and further evaluate the performance of the squid ink polysaccharide-chitosan sponge (SIP-CS). The optimized formulation of SIP-CS was as follows: chitosan concentration, 2.29%; squid ink polysaccharide concentration, 0.55%; and calcium chloride concentration, 2.82%, at a volume ratio of 15:5:2. SIP-CS was conducive to sticking on the wound, characterized by the spongy property, strong absorptivity, and tackiness. Rabbit ear arterial, hepatic, and femoral artery hemorrhage experiments indicated that, compared with chitosan dressings and absorbable gelatin, the hemostatic times were shorter and the bleeding volume was smaller. Furthermore, SIP-CS absorbed a large amount of hemocytes, leading to rapid hemostasis. The healing areas and wound pathological sections in scalded New Zealand rabbits indicated that SIP-CS promoted wound healing more rapidly than chitosan and better than commercially available burn cream. Thus, SIP-CS is a good wound healing agent for rapid hemostasis, promoting burn/scalded skin healing, and protecting from wound infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Greatly improved cache update times for conditions data with Frontier/Squid

    Energy Technology Data Exchange (ETDEWEB)

    Dykstra, Dave; Lueking, Lee, E-mail: dwd@fnal.go [Computing Division, Fermilab, Batavia, IL (United States)

    2010-04-01

    The CMS detector project loads copies of conditions data to over 100,000 computer cores worldwide by using a software subsystem called Frontier. This subsystem translates database queries into HTTP, looks up the results in a central database at CERN, and caches the results in an industry-standard HTTP proxy/caching server called Squid. One of the most challenging aspects of any cache system is coherency, that is, ensuring that changes made to the underlying data get propagated out to all clients in a timely manner. Recently, the Frontier system was enhanced to drastically reduce the time for changes to be propagated everywhere without heavily loading servers. The propagation time is now as low as 15 minutes for some kinds of data and no more than 60 minutes for the rest of the data. This was accomplished by taking advantage of an HTTP and Squid feature called If-Modified-Since. In order to use this feature, the Frontier server sends a Last-Modified timestamp, but since modification times are not normally tracked by Oracle databases, a PL/SQL program was developed to track the modification times of database tables. We discuss the details of this caching scheme and the obstacles overcome including database and Squid bugs.

  9. Chitinolytic Bacteria-Assisted Conversion of Squid Pen and Its Effect on Dyes and Pigments Adsorption

    Directory of Open Access Journals (Sweden)

    Tzu-Wen Liang

    2015-07-01

    Full Text Available The aim of this work was to produce chitosanase by fermenting from squid pen, and recover the fermented squid pen for dye removal by adsorption. One chitosanase induced from squid pen powder (SPP-containing medium by Bacillus cereus TKU034 was purified in high purification fold (441 and high yield of activity recovery (51% by ammonium sulfate precipitation and combined column chromatography. The SDS-PAGE results showed its molecular mass to be around 43 kDa. The TKU034 chitosanase used for the chitooligomers preparation was studied. The enzyme products revealed that the chitosanase could degrade chitosan with various degrees of polymerization, ranging from 3 to 9, as well as the chitosanase in an endolytic manner. Besides, the fermented SPP was recovered and displayed a better adsorption rate (up to 99.5% for the disperse dyes (red, yellow, blue, and black than the water-soluble food colorants, Allura Red AC (R40 and Tartrazine (Y4. The adsorbed R40 on the unfermented SPP and the fermented SPP was eluted by distilled water and 1 M NaOH to confirm the dye adsorption mechanism. The fermented SPP had a slightly higher adsorption capacity than the unfermented, and elution of the dye from the fermented SPP was easier than from the unfermented. The main dye adsorption mechanism of fermented SPP was physical adsorption, while the adsorption mechanism of unfermented SPP was chemical adsorption.

  10. Chitinolytic Bacteria-Assisted Conversion of Squid Pen and Its Effect on Dyes and Pigments Adsorption.

    Science.gov (United States)

    Liang, Tzu-Wen; Lo, Bo-Chang; Wang, San-Lang

    2015-07-23

    The aim of this work was to produce chitosanase by fermenting from squid pen, and recover the fermented squid pen for dye removal by adsorption. One chitosanase induced from squid pen powder (SPP)-containing medium by Bacillus cereus TKU034 was purified in high purification fold (441) and high yield of activity recovery (51%) by ammonium sulfate precipitation and combined column chromatography. The SDS-PAGE results showed its molecular mass to be around 43 kDa. The TKU034 chitosanase used for the chitooligomers preparation was studied. The enzyme products revealed that the chitosanase could degrade chitosan with various degrees of polymerization, ranging from 3 to 9, as well as the chitosanase in an endolytic manner. Besides, the fermented SPP was recovered and displayed a better adsorption rate (up to 99.5%) for the disperse dyes (red, yellow, blue, and black) than the water-soluble food colorants, Allura Red AC (R40) and Tartrazine (Y4). The adsorbed R40 on the unfermented SPP and the fermented SPP was eluted by distilled water and 1 M NaOH to confirm the dye adsorption mechanism. The fermented SPP had a slightly higher adsorption capacity than the unfermented, and elution of the dye from the fermented SPP was easier than from the unfermented. The main dye adsorption mechanism of fermented SPP was physical adsorption, while the adsorption mechanism of unfermented SPP was chemical adsorption.

  11. Greatly improved cache update times for conditions data with Frontier/Squid

    International Nuclear Information System (INIS)

    Dykstra, Dave; Lueking, Lee

    2009-01-01

    The CMS detector project loads copies of conditions data to over 100,000 computer cores worldwide by using a software subsystem called Frontier. This subsystem translates database queries into HTTP, looks up the results in a central database at CERN, and caches the results in an industry-standard HTTP proxy/caching server called Squid. One of the most challenging aspects of any cache system is coherency, that is, ensuring that changes made to the underlying data get propagated out to all clients in a timely manner. Recently, the Frontier system was enhanced to drastically reduce the time for changes to be propagated everywhere without heavily loading servers. The propagation time is now as low as 15 minutes for some kinds of data and no more than 60 minutes for the rest of the data. This was accomplished by taking advantage of an HTTP and Squid feature called If-Modified-Since. In order to use this feature, the Frontier server sends a Last-Modified timestamp, but since modification times are not normally tracked by Oracle databases, a PL/SQL program was developed to track the modification times of database tables. We discuss the details of this caching scheme and the obstacles overcome including database and Squid bugs.

  12. Growth and flagellation of Vibrio fischeri during initiation of the sepiolid squid light organ symbiosis.

    Science.gov (United States)

    Ruby, E G; Asato, L M

    1993-01-01

    A pure culture of the luminous bacterium Vibrio fischeri is maintained in the light-emitting organ of the sepiolid squid Euprymna scolopes. When the juvenile squid emerges from its egg it is symbiont-free and, because bioluminescence is part of an anti-predatory behavior, therefore must obtain a bacterial inoculum from the surrounding environment. We document here the kinetics of the process by which newly hatched juvenile squids become infected by symbiosis-competent V. fischeri. When placed in seawater containing as few as 240 colony-forming-units (CFU) per ml, the juvenile became detectably bioluminescent within a few hours. Colonization of the nascent light organ was initiated with as few as 1 to 10 bacteria, which rapidly began to grow at an exponential rate until they reached a population size of approximately 10(5) cells by 12 h after the initial infection. Subsequently, the number of bacteria in the established symbiosis was maintained essentially constant by a combination of both a > 20-fold reduction in bacterial growth rate, and an expulsion of excess bacteria into the surrounding seawater. While V. fischeri cells are normally flagellated and motile, these bacteria did not elaborate these appendages once the symbiosis was established; however, they quickly began to synthesize flagella when they were removed from the light organ environment. Thus, two important biological characteristics, growth rate and flagellation, were modulated during establishment of the association, perhaps as part of a coordinated series of symbiotic responses.

  13. Ultraviolet Laser SQUID Microscope for GaN Blue Light Emitting Diode Testing

    International Nuclear Information System (INIS)

    Daibo, M; Kamiwano, D; Kurosawa, T; Yoshizawa, M; Tayama, N

    2006-01-01

    We carried out non-contacting measurements of photocurrent distributions in GaN blue light emitting diode (LED) chips using our newly developed ultraviolet (UV) laser SQUID microscope. The UV light generates the photocurrent, and then the photocurrent induces small magnetic fields around the chip. An off-axis arranged HTS-SQUID magnetometer is employed to detect a vector magnetic field whose typical amplitude is several hundred femto-tesla. Generally, it is difficult to obtain Ohmic contacts for p-type GaN because of the low hole concentration in the p-type epitaxial layer and the lack of any available metal with a higher work function compared with the p-type GaN. Therefore, a traditional probecontacted electrical test is difficult to conduct for wide band gap semiconductors without an adequately annealed electrode. Using the UV-laser SQUID microscope, the photocurrent can be measured without any electrical contact. We show the photocurrent vector map which was reconstructed from measured magnetic fields data. We also demonstrate how we found the position of a defect of the electrical short circuits in the LED chip

  14. HTS-SQUID NDE Technique for Pipes based on Ultrasonic Guided Wave

    Science.gov (United States)

    Hatsukade, Y.; Masutani, N.; Teranishi, S.; Masamoto, K.; Kanenaga, S.; Adachi, S.; Tanabe, K.

    2017-07-01

    This article describes research on the novel high-temperature superconductor (HTS) superconducting quantum interference device (SQUID) non-destructive evaluation (NDE) technique for metallic pipes based on ultrasonic guided waves. We constructed HTS-SQUID NDE system for pipes based on ultrasonic guided waves, which were generated and received by means of the magnetostrictive effects. Using the system, we measured magnetic signals due to T (0, 1) mode ultrasonic guided waves that transmitted on aluminium pipe, and investigated influences of measurement parameters to the magnetic signals, such as direction of a HTS-SQUID gradiometer, lift-off distance, and intensity and frequency of input current fed to a magnetostrictive transmitter. With the gradiometer oriented parallel to the pipe axis, more than 10 times larger signals were measured compared with that oriented perpendicular to the pipe axis. Magnetic signals measured by the gradiometer were inverse proportional to the power of the list- off distance, and proportional to the intensity of the input current up to 1 App. Relation between the frequency of the input current and the measured signal was shown and discussed.

  15. Design and Characterization of Low-noise Dewar for High-sensitivity SQUID Operation

    International Nuclear Information System (INIS)

    Yu, K. K.; Lee, Y. H.; Kim, K.; Kwon, H.; Kim, J. M.

    2010-01-01

    We have fabricated the low noise liquid helium(LHe) dewar with a different shape of thermal shield to apply the 64-channel SQUID(Superconducting Quantum Interference Device) gradiometer. The first shape of thermal shield was made of an aluminum plate with a wide width of 100 mm slit and the other shape was modified with a narrow width of 20 mm slit. The two types of dewars were estimated by comparing the thermal noise and the signal-to-noise ratio(SNR) of magnetocardiography(MCG) using the 1st order SQUID gradiometer system cooled each dewar. The white noise was different as a point of the dewar. The noise was increased as close as the edge of dewar, and also increased at the thermal shield with the more wide width slit. The white noise of the dewar with thermal shield of 100 mm slit was 6.5 fT/Hz 1/2 at the center of dewar and 25 fT/Hz 1/2 at the edge, and the white noise of the other one was 3.5 - 7 fT/Hz 1/2 . We measured the MCG using 64-channel SQUID gradiometer cooled at each LHe dewar and compared the SNR of MCG signal. The SNR was improved of 10 times at the LHe dewar with a modified thermal shield.

  16. Chitinolytic Bacteria-Assisted Conversion of Squid Pen and Its Effect on Dyes and Pigments Adsorption

    Science.gov (United States)

    Liang, Tzu-Wen; Lo, Bo-Chang; Wang, San-Lang

    2015-01-01

    The aim of this work was to produce chitosanase by fermenting from squid pen, and recover the fermented squid pen for dye removal by adsorption. One chitosanase induced from squid pen powder (SPP)-containing medium by Bacillus cereus TKU034 was purified in high purification fold (441) and high yield of activity recovery (51%) by ammonium sulfate precipitation and combined column chromatography. The SDS-PAGE results showed its molecular mass to be around 43 kDa. The TKU034 chitosanase used for the chitooligomers preparation was studied. The enzyme products revealed that the chitosanase could degrade chitosan with various degrees of polymerization, ranging from 3 to 9, as well as the chitosanase in an endolytic manner. Besides, the fermented SPP was recovered and displayed a better adsorption rate (up to 99.5%) for the disperse dyes (red, yellow, blue, and black) than the water-soluble food colorants, Allura Red AC (R40) and Tartrazine (Y4). The adsorbed R40 on the unfermented SPP and the fermented SPP was eluted by distilled water and 1 M NaOH to confirm the dye adsorption mechanism. The fermented SPP had a slightly higher adsorption capacity than the unfermented, and elution of the dye from the fermented SPP was easier than from the unfermented. The main dye adsorption mechanism of fermented SPP was physical adsorption, while the adsorption mechanism of unfermented SPP was chemical adsorption. PMID:26213948

  17. SQUID multiplexing using baseband feedback for space application of transition-edge sensor microcalorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Takei, Y; Yamasaki, N Y; Hirakoso, W; Kimura, S; Mitsuda, K, E-mail: takei@astro.isas.jaxa.j [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Sagamihara, 229-8510 (Japan)

    2009-11-15

    A microcalorimeter array based on a transition-edge sensor (TES) thermometer is a promising imaging spectrometer for use in future x-ray astronomy missions. A TES microcalorimeter achieves {approx}<5 eV energy resolution and an array of >100 pixels also provides a moderate imaging capability. For a large format array, signal multiplexing at the low temperature stage is mandatory in order to reduce heat loads from cold stage preamplifiers and through wirings. We are developing frequency division multiplexing (FDM). In FDM, each TES is ac-biased with a different carrier frequency. Signals from several pixels are summed and then read out by one dc SQUID (superconducting quantum interference device). The maximum number of multiplexed pixels is limited by the bandwidth of a SQUID in a flux-locked loop. Assuming 1 m cable length between the room temperature and the cold stage, the bandwidth is only <1 MHz with a standard flux-locked loop, due to the delay and phase shift of wirings. We report our development of baseband feedback, a new feedback scheme that overcomes the bandwidth limitation. In baseband feedback, the signal ({approx}<10 kHz) from the TES is sent back to the SQUID after the phase of carrier frequency ({approx}1 MHz) has been adjusted. We demonstrated open-loop gain of 8 for 10 kHz signal at 5 MHz carrier frequency, which indicates the possibility of {approx}40-pixel multiplexing of the TES signal.

  18. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  19. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  20. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  1. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  2. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  3. High-resolution imaging of magnetic fields using scanning superconducting quantum interference device (SQUID) microscopy

    Science.gov (United States)

    Fong de Los Santos, Luis E.

    Development of a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with sub-millimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensor is mounted in the tip of a sapphire rod and thermally anchored to the cryostat helium reservoir. A 25 mum sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows adjusting the sample-to-sensor spacing from the top of the Dewar. I have achieved a sensor-to-sample spacing of 100 mum, which could be maintained for periods of up to 4 weeks. Different SQUID sensor configurations are necessary to achieve the best combination of spatial resolution and field sensitivity for a given magnetic source. For imaging thin sections of geological samples, I used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80 mum, and achieved a field sensitivity of 1.5 pT/Hz1/2 and a magnetic moment sensitivity of 5.4 x 10-18 Am2/Hz1/2 at a sensor-to-sample spacing of 100 mum in the white noise region for frequencies above 100 Hz. Imaging action currents in cardiac tissue requires higher field sensitivity, which can only be achieved by compromising spatial resolution. I developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250 mum to 1 mm, and achieved sensitivities of 480 - 180 fT/Hz1/2 in the white noise region for frequencies above 100 Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of

  4. Emulsifying and gelling properties of weakfish myofibrillar proteins as affected by squid mantle myofibrillar proteins in a model system

    Directory of Open Access Journals (Sweden)

    Daniela Mariel Suarez

    2014-03-01

    Full Text Available The aim of the present work was to investigate the physicochemical, biochemical and functional characteristics of both the myofibrils (MF and actomyosin (AM of squid mantle (Illex argentinus and weakfish (Cynoscion guatucupa muscles, and evaluate the influence of the addition of myofibrilar proteins from the squid mantle on the physicochemical and functional properties of those of the weakfish. After extraction, purification and characterization of the MF and AM of both species, emulsions of each protein fraction from each muscle were formulated. Mixtures of the MF or AM of both species were also analyzed. The emulsifying properties were monitoring using the Emulsifying Activity Index (EAI and Emulsion Stability (ES. In addition, gel pastes were formulated from the squid mantle, weakfish muscle and the mixture of both species, and the following functional properties of the gels assessed: water holding capacity, colour, textural profile analysis (TPA (hardness, elasticity, cohesiveness, gumminess and gel strength. The EAI values of emulsions formulated with the MF of the mantle were significantly (p<0.05 higher than those formulated from those of weakfish. The incorporation of squid MF in the mixture increased the EAI values. Conversely, the highest ES values were obtained with weakfish MF, and the incorporation of MF weakfish in the mixture increased the ES values. Similar EAI and ES behaviours were observed for the AM of the corresponding species. Irrespective of the thermal treatment, the gel strength of the gelled paste of squid muscle was significantly (p<0.05 lower than that of weakfish muscle and of those obtained with the different mixtures. The behaviours of the expressible moisture (EM from the gelled pastes were similar to those of gel strength. Irrespective of the thermal treatment, the pastes formulated with a high weakfish: mantle ratio showed less water loss. The gelled pastes of squid mantle showed the highest values for whiteness

  5. Chronic Treatment with Squid Phosphatidylserine Activates Glucose Uptake and Ameliorates TMT-Induced Cognitive Deficit in Rats via Activation of Cholinergic Systems

    Directory of Open Access Journals (Sweden)

    Hyun-Jung Park

    2012-01-01

    Full Text Available The present study examined the effects of squid phosphatidylserine (Squid-PS on the learning and memory function and the neural activity in rats with TMT-induced memory deficits. The rats were administered saline or squid derived Squid-PS (Squid-PS 50 mg kg−1, p.o. daily for 21 days. The cognitive improving efficacy of Squid-PS on the amnesic rats, which was induced by TMT, was investigated by assessing the passive avoidance task and by performing choline acetyltransferase (ChAT and acetylcholinesterase (AchE immunohistochemistry. 18F-Fluorodeoxyglucose and performed a positron emission tomography (PET scan was also performed. In the passive avoidance test, the control group which were injected with TMT showed a markedly lower latency time than the non-treated normal group (P<0.05. However, treatment of Squid-PS significantly recovered the impairment of memory compared to the control group (P<0.05. Consistent with the behavioral data, Squid-PS significantly alleviated the loss of ChAT immunoreactive neurons in the hippocampal CA3 compared to that of the control group (P<0.01. Also, Squid-PS significantly increased the AchE positive neurons in the hippocampal CA1 and CA3. In the PET analysis, Squid-PS treatment increased the glucose uptake more than twofold in the frontal lobe and the hippocampus (P<0.05, resp.. These results suggest that Squid-PS may be useful for improving the cognitive function via regulation of cholinergic enzyme activity and neural activity.

  6. Development of the Human Factors Skills for Healthcare Instrument: a valid and reliable tool for assessing interprofessional learning across healthcare practice settings.

    Science.gov (United States)

    Reedy, Gabriel B; Lavelle, Mary; Simpson, Thomas; Anderson, Janet E

    2017-10-01

    A central feature of clinical simulation training is human factors skills, providing staff with the social and cognitive skills to cope with demanding clinical situations. Although these skills are critical to safe patient care, assessing their learning is challenging. This study aimed to develop, pilot and evaluate a valid and reliable structured instrument to assess human factors skills, which can be used pre- and post-simulation training, and is relevant across a range of healthcare professions. Through consultation with a multi-professional expert group, we developed and piloted a 39-item survey with 272 healthcare professionals attending training courses across two large simulation centres in London, one specialising in acute care and one in mental health, both serving healthcare professionals working across acute and community settings. Following psychometric evaluation, the final 12-item instrument was evaluated with a second sample of 711 trainees. Exploratory factor analysis revealed a 12-item, one-factor solution with good internal consistency (α=0.92). The instrument had discriminant validity, with newly qualified trainees scoring significantly lower than experienced trainees ( t (98)=4.88, pSkills for Healthcare Instrument provides a reliable and valid method of assessing trainees' human factors skills self-efficacy across acute and mental health settings. This instrument has the potential to improve the assessment and evaluation of human factors skills learning in both uniprofessional and interprofessional clinical simulation training.

  7. Seasonal Habitat Patterns of Japanese Common Squid (Todarodes Pacificus Inferred from Satellite-Based Species Distribution Models

    Directory of Open Access Journals (Sweden)

    Irene D. Alabia

    2016-11-01

    Full Text Available The understanding of the spatio-temporal distributions of the species habitat in the marine environment is central to effectual resource management and conservation. Here, we examined the potential habitat distributions of Japanese common squid (Todarodes pacificus in the Sea of Japan during a four-year period. The seasonal patterns of preferential habitat were inferred from species distribution models, built using squid occurrences detected from night-time visible images and remotely-sensed environmental factors. The predicted squid habitat (i.e., areas with high habitat suitability revealed strong seasonal variability, characterized by a reduction of potential habitat, confined off of the southern part of the basin during the winter–spring period (December–May. Apparent expansion of preferential habitat occurred during summer–autumn months (June–November, concurrent with the formation of highly suitable habitat patches in certain regions of the Sea of Japan. These habitat distribution patterns were in response to changes in oceanographic conditions and synchronous with seasonal migration of squid. Moreover, the most important variables regulating the spatio-temporal patterns of suitable habitat were sea surface temperature, depth, sea surface height anomaly, and eddy kinetic energy. These variables could affect the habitat distributions through their impacts on growth and survival of squid, local nutrient transport, and the availability of favorable spawning and feeding grounds.

  8. Extreme plasticity in life-history strategy allows a migratory predator (jumbo squid) to cope with a changing climate.

    Science.gov (United States)

    Hoving, Henk-Jan T; Gilly, William F; Markaida, Unai; Benoit-Bird, Kelly J; -Brown, Zachary W; Daniel, Patrick; Field, John C; Parassenti, Liz; Liu, Bilin; Campos, Bernardita

    2013-07-01

    Dosidicus gigas (jumbo or Humboldt squid) is a semelparous, major predator of the eastern Pacific that is ecologically and commercially important. In the Gulf of California, these animals mature at large size (>55 cm mantle length) in 1-1.5 years and have supported a major commercial fishery in the Guaymas Basin during the last 20 years. An El Niño event in 2009-2010, was accompanied by a collapse of this fishery, and squid in the region showed major changes in the distribution and life-history strategy. Large squid abandoned seasonal coastal-shelf habitats in 2010 and instead were found in the Salsipuedes Basin to the north, an area buffered from the effects of El Niño by tidal upwelling and a well-mixed water column. The commercial fishery also relocated to this region. Although large squid were not found in the Guaymas Basin from 2010 to 2012, small squid were abundant and matured at an unusually small mantle-length (adapt to and cope with El Niño. This ability is likely to be an important factor in conjunction with longerterm climate-change and the potential ecological impacts of this invasive predator on marine ecosystems. © 2013 Blackwell Publishing Ltd.

  9. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  10. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  11. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  12. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  13. Instrumental aspects

    Directory of Open Access Journals (Sweden)

    Qureshi Navid

    2017-01-01

    Full Text Available Every neutron scattering experiment requires the choice of a suited neutron diffractometer (or spectrometer in the case of inelastic scattering with its optimal configuration in order to accomplish the experimental tasks in the most successful way. Most generally, the compromise between the incident neutron flux and the instrumental resolution has to be considered, which is depending on a number of optical devices which are positioned in the neutron beam path. In this chapter the basic instrumental principles of neutron diffraction will be explained. Examples of different types of experiments and their respective expectable results will be shown. Furthermore, the production and use of polarized neutrons will be stressed.

  14. Standard NIM instrumentation system

    International Nuclear Information System (INIS)

    1990-05-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID-20893 (Rev. 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice

  15. Effect of Melanin Free Ink Extracted From Squid (Loligo sp.) on Proximate and Sensory Characteristics of Soft-Bone Milkfish (Chanos chanos) During Storage

    Science.gov (United States)

    Winarni Agustini, Tri; Hadiyanto; Wijayanti, Ima; Amalia, Ulfah; Benjakul, Soottawat

    2018-02-01

    Antioxidant could be extracted and isolated from squid inks. Squid ink in the form of melanin free ink (MFI) could be act as an electron donor which can stabilize free radicals in lipid oxidation. This study was carried out to assess the antioxidant activity of squid inks converted into MFI in different dilution and to optimize the extraction conditions for the application of MFI as an antioxidative agent on fish product. Three different types of MFI extracts i.e : pure squid ink, squid ink with 5 times dilution and squid ink with 10 times dilutions by using cooled ionized water (4°C). The ink was then centrifuged at 18.000 x g for 30 minutes at cooled centrifuge (4°C) followed by DPPH analysis. The results showed that the IC50 of MFI extracts were 2.84 ppm; 1.11 ppm and 0.34 ppm, respectively (p squid ink with 10 times dilution in extraction of MFI had the highest value in free radical inhibitory. Although the IC50 of three different dilutions are equally low, and are considered as very strong antioxidative agent, however, it showed that the MFI extracted from squid ink had the ability to prevent free radical

  16. Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

    Energy Technology Data Exchange (ETDEWEB)

    Chesca, Boris, E-mail: B.Chesca@lboro.ac.uk; John, Daniel [Department of Physics, Loughborough University, Loughborough LE11 3TU (United Kingdom); Mellor, Christopher J. [School of Physics and Astronomy, Nottingham University, Nottingham NG7 2RD (United Kingdom)

    2015-10-19

    A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S{sub Φ}{sup 1/2} decreases as 1/N{sup 1/2}. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa{sub 2}Cu{sub 3}O{sub 7}. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S{sub Φ}{sup 1/2} between (0.25 and 0.44) μΦ{sub 0}/Hz{sup 1/2} for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

  17. Surgical Instrument

    NARCIS (Netherlands)

    Dankelman, J.; Horeman, T.

    2009-01-01

    The present invention relates to a surgical instrument for minimall-invasive surgery, comprising a handle, a shaft and an actuating part, characterised by a gastight cover surrounding the shaft, wherein the cover is provided with a coupler that has a feed- through opening with a loskable seal,

  18. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  19. Intense Ultrasonic clicks from echolocating toothed whales do not elicit anti-predator responses or debilitate the squid Loligo pealeii

    DEFF Research Database (Denmark)

    Wilson, Maria; Hanlon, Roger; Tyack, Peter

    2007-01-01

    an evolutionary selection pressure on cephalopods to develop a mechanism for detecting and evading sound-emitting toothed whale predators. Ultrasonic detection has evolved in some insects to avoid echolocating bats, and it can be hypothesized that cephalopods might have evolved similar ultrasound detection...... as an anti-predation measure. We test this hypothesis in the squid Loligo pealeii in a playback experiment using intense echolocation clicks from two squid-eating toothed whale species. Twelve squid were exposed to clicks at two repetition rates (16 and 125 clicks per second) with received sound pressure...... levels of 199-226dBre1μPa (pp) mimicking the sound exposure from an echolocating toothed whale as it approaches and captures prey. We demonstrate that intense ultrasonic clicks do not elicit any detectable anti-predator behaviour in L. pealeii and that clicks with received levels up to 226dBre1μPa (pp...

  20. A novel squid pen chitosan/hydroxyapatite/β-tricalcium phosphate composite for bone tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Shavandi, Amin, E-mail: amin.shavandi@postgrad.otago.ac.nz [Department of Food Sciences, University of Otago, Dunedin (New Zealand); Department of Applied Sciences, University of Otago, Dunedin (New Zealand); Bekhit, Alaa El-Din A. [Department of Food Sciences, University of Otago, Dunedin (New Zealand); Sun, Zhifa; Ali, Azam [Department of Physics, University of Otago, Dunedin (New Zealand); Gould, Maree [Department of Anatomy, University of Otago, Dunedin (New Zealand)

    2015-10-01

    Squid pen chitosan was used in the fabrication of biocomposite scaffolds for bone tissue engineering. Hydroxyapatite (HA) and beta-tricalcium phosphate (β-TCP) obtained from waste mussel shells were used as the calcium phosphate source. The composite was prepared using 2.5% tripolyphosphate (TPP) and 1% glycerol as a cross-linker and plasticizer, respectively. The weight percent (wt.%) ratios of the ceramic components in the composite were 20/10/70, 30/20/50 and 40/30/30 (HA/β-TCP/Chi). The biodegradation rate and structural properties of the scaffolds were investigated. Scanning electron microscopy (SEM) and microCT(μCT) results indicated that the composites have a well defined lamellar structure with an average pore size of 200 μm. The porosity of the composites decreased from 88 to 56% by increasing the ratio of HA/β-TCP from 30 to 70%. After 28 days of incubation in a physiological solution, the scaffolds were degraded by approximately 30%. In vitro investigations showed that the composites were cytocompatible and supported the growth of L929 and Saos-2 cells. The obtained data suggests that the squid pen chitosan composites are potential candidates for bone regeneration. - Highlights: • Biocomposite scaffolds were made from mussel shells HA and β-TCP, and squid pin chitosan. • The porosity of the composites decreased with an increase in HA/β-TCP ratio. • Composites were cytocompatible and supported the growth of L929 and Saos-2 cells. • Composite containing 50% HA and β-TCP had the best mechanical properties.

  1. Characteristics regarding the consumer of giant squid from Baja California Sur, Mexico

    Directory of Open Access Journals (Sweden)

    Liliana Enriqueta Montaño Méndez

    2015-01-01

    Full Text Available The catch of the giant squid (Dosidicus gigas, represents de second fishing activity most important in volume in Baja California Sur, Mexico; is an essential specie not only at the state level but at the pacific and even the national level. Mexico occupies in the world the eight level in the production of squid, but the national consumption, even though the low price of the product and the high nutritional level, is approximately 0.53 kg per year, very low compared to countries like Japan, Korea and Spain (average consumption per capita is of 3.5 kg . In this context, the objective of this article is to caracterize the sudcalifornia consumer preference; determine the buying habits and the consumption; and also to establish the market areas of the squid in Baja California Sur, which allows the introduction of actions for its commercialization, in order to strengthen the market of this product and its general activity. This is why in 2012 a questioner of 1066 consumers was distribute around the five counties of the state, according to the population density. The results indicate that the principal motive why there is not consumption is the difficulty to find places where to buy it, together with the problems of cooking it. Also, it can be seen the high level of ignorance the consumer has regarding the nutritional level this food has. For this reason, future strategies for the commercialization must be focus on better distribution and new form of presenting this product which facilitates its preparation and consumption, and at the same time create campaign which increase awareness of the nutrition level this product has.

  2. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    Science.gov (United States)

    Bechstein, S.; Petsche, F.; Scheiner, M.; Drung, D.; Thiel, F.; Schnabel, A.; Schurig, Th

    2006-06-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/√Hz was specially designed for a 304-channel low-Tc dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm × 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm × 4 cm × 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented.

  3. Dimorphic ejaculates and sperm release strategies associated with alternative mating behaviors in the squid.

    Science.gov (United States)

    Apostólico, Lígia H; Marian, José E A R

    2017-11-01

    Sperm competition is a powerful postcopulatory selective force influencing male adaptations associated with increasing fertilization success, and it is usually related to the evolution of different strategies of ejaculate expenditure between individuals. Ejaculates may also be influenced by additional selective pressures associated with sperm competition, such as timing between insemination and fertilization, female reproductive tract morphology, and fertilization environment. Also, males that adopt alternative mating tactics may face distinct sperm competition pressures, which may lead to the evolution of intraspecific diversity in ejaculates. In loliginid squids, males with alternative reproductive tactics (sneakers and consorts) differ not only in mating behavior, but also transfer spermatophores into two distinct sites within the female. Here, we compared structure and functioning of spermatophores between sneakers and consorts in the squid Doryteuthis plei applying microscopy techniques and in vitro experiments. Sneakers and consorts exhibit differences in spermatophore structure that lead to distinct spermatophoric reactions and spermatangium morphologies. Moreover, in sneakers, sperm release lasts longer and their sperm show an aggregative behavior not detected in consorts. Slow sperm release may be a strategy to guarantee longer sperm provision, given the wide interval between sneaker mating and egg release. For consorts, in turn, intense and quick sperm discharge may be advantageous, as timing between mating and egg-laying is relatively short. Within the complex squid mating system, factors such as (i) different fertilization sites and (ii) interval between mating and egg release may also influence sperm competition, and ultimately shape the evolution of divergent ejaculates between dimorphic males. © 2017 Wiley Periodicals, Inc.

  4. CO2-level Dependent Effects of Ocean Acidification on Squid, Doryteuthis pealeii, Early Life History

    KAUST Repository

    Zakroff, Casey J.

    2013-12-01

    Ocean acidification is predicted to lead to global oceanic decreases in pH of up to 0.3 units within the next 100 years. However, those levels are already being reached currently in coastal regions due to natural CO2 variability. Squid are a vital component of the pelagic ecosystem, holding a unique niche as a highly active predatory invertebrate and major prey stock for upper trophic levels. This study examined the effects of a range of ocean acidification regimes on the early life history of a coastal squid species, the Atlantic longfin squid, Doryteuthis pealeii. Eggs were raised in a flow-through ocean acidification system at CO2 levels ranging from ambient (400ppm) to 2200ppm. Time to hatching, hatching efficiency, and hatchling mantle lengths, yolk sac sizes, and statoliths were all examined to elucidate stress effects. Delays in hatching time of at least a day were seen at exposures above 1300ppm in all trials under controlled conditions. Mantle lengths were significantly reduced at exposures above 1300 ppm. Yolk sac sizes varied between CO2 treatments, but no distinct pattern emerged. Statoliths were increasingly porous and malformed as CO2 exposures increased, and were significantly reduced in surface area at exposures above 1300ppm. Doryteuthis pealeii appears to be able to withstand acidosis stress without major effects up to 1300ppm, but is strongly impacted past that threshold. Since yolk consumption did not vary among treatments, it appears that during its early life stages, D. pealeii reallocates its available energy budget away from somatic growth and system development in order to mitigate the stress of acidosis.

  5. Detection and quantification of Vibrio fischeri autoinducer from symbiotic squid light organs.

    Science.gov (United States)

    Boettcher, K J; Ruby, E G

    1995-02-01

    Vibrio fischeri is the specific light organ symbiont of the sepiolid squid species Euprymna scolopes and Euprymna morsei. Both species of squid are luminescent by virtue of their bacterial symbionts, but the natural symbionts of E. scolopes do not produce visible luminescence in laboratory culture. The primary cause of this depressed luminescence by E. scolopes symbionts in culture was found to be the production of relatively low levels of V. fischeri autoinducer, a positive transcriptional coregulator of the lux regulon, identified as N-(3-oxohexanoyl) homoserine lactone. Concentrations of autoinducer activity produced by these symbionts in culture were quantified and found to be at least 10-fold lower than those produced by E. morsei isolates (which are visibly luminous outside the association) and perhaps 10,000-fold lower than those of the brightest V. fischeri strains. Despite the differences in their symbiont strains, the intact light organs of the two species of squid contained comparable amounts of extractable autoinducer activity (between 100 and 200 pg per adult animal). The chromatographic behavior of this autoinducer activity on reverse-phase high-performance liquid chromatography was consistent with its presumptive identification as V. fischeri autoinducer. Within the 5-microliter volume of the epithelial core of the light organ in which the symbiotic V. fischeri strains are housed, these amounts would result in an effective autoinducer concentration of at least 100 nM. Because these levels are over 40-fold higher than the concentration needed for the induction of luminescence of bacteria in culture, we conclude that the inherent degree of autoinducer production by strains of V. fischeri may not influence their effectiveness as light organ symbionts. Furthermore, this study provides the first direct evidence that the phenomenon of cell density-dependent autoinduction, discovered and described first for laboratory cultures of V. fischeri but believed to

  6. Bacterial bioluminescence regulates expression of a host cryptochrome gene in the squid-Vibrio symbiosis.

    Science.gov (United States)

    Heath-Heckman, Elizabeth A C; Peyer, Suzanne M; Whistler, Cheryl A; Apicella, Michael A; Goldman, William E; McFall-Ngai, Margaret J

    2013-04-02

    The symbiosis between the squid Euprymna scolopes and its luminous symbiont, Vibrio fischeri, is characterized by daily transcriptional rhythms in both partners and daily fluctuations in symbiont luminescence. In this study, we sought to determine whether symbionts affect host transcriptional rhythms. We identified two transcripts in host tissues (E. scolopes cry1 [escry1] and escry2) that encode cryptochromes, proteins that influence circadian rhythms in other systems. Both genes cycled daily in the head of the squid, with a pattern similar to that of other animals, in which expression of certain cry genes is entrained by environmental light. In contrast, escry1 expression cycled in the symbiont-colonized light organ with 8-fold upregulation coincident with the rhythms of bacterial luminescence, which are offset from the day/night light regime. Colonization of the juvenile light organ by symbionts was required for induction of escry1 cycling. Further, analysis with a mutant strain defective in light production showed that symbiont luminescence is essential for cycling of escry1; this defect could be complemented by presentation of exogenous blue light. However, blue-light exposure alone did not induce cycling in nonsymbiotic animals, but addition of molecules of the symbiont cell envelope to light-exposed animals did recover significant cycling activity, showing that light acts in synergy with other symbiont features to induce cycling. While symbiont luminescence may be a character specific to rhythms of the squid-vibrio association, resident microbial partners could similarly influence well-documented daily rhythms in other systems, such as the mammalian gut.

  7. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    International Nuclear Information System (INIS)

    Bechstein, S; Petsche, F; Scheiner, M; Drung, D; Thiel, F; Schnabel, A; Schurig, Th

    2006-01-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/√Hz was specially designed for a 304-channel low-T c dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm x 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm x 4 cm x 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented

  8. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Bechstein, S [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Petsche, F [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Scheiner, M [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Drung, D [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Thiel, F [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Schnabel, A [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Schurig, Th [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2006-06-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/{radical}Hz was specially designed for a 304-channel low-T{sub c} dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm x 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm x 4 cm x 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented.

  9. Fishing ground distribution of neon flying squid ( Ommastrephes bartramii) in relation to oceanographic conditions in the Northwest Pacific Ocean

    Science.gov (United States)

    Yu, Wei; Chen, Xinjun; Yi, Qian

    2017-12-01

    Neon flying squid, Ommastrephes bartramii, is a squid species of the North Pacific Ocean, which plays an important economical role in the international fishery. Logbook data for Chinese squid-jigging fishery over 2004-2011 were used to evaluate the relationship between the fishing grounds of the squid and the convergent frontal areas, which were defined by the contour lines of specific sea surface temperature (SST) and chlorophyll- a (Chl- a) concentration. Our results indicate that the SST in the range of 15 to 19°C and the Chl- a concentration in the range of 0.1 to 0.4 mg m-3 are the favorable conditions for the aggregation of the squid. Additionally, we deduced that the SST at 17.5°C and the Chl- a concentration at 0.25 mg m-3 are the optimal environmental conditions for the aggregation of O. bartramii. In August, the annual CPUE is positively correlated with the proportion of the fishing grounds with favorable SST and Chl- a concentration, as well as the combination of the two variables, implying that the abundance of the squid annually is largely depending on the presence of the favorable environmental conditions for fishery in August. Minor spatial difference between mean latitudinal location of the 17.5°C SST and 0.25 mg m-3 Chl- a fronts can increase the CPUEs of O. bartramii. Furthermore, the monthly latitudinal gravity centers of the CPUE closely followed the mean latitudinal position of the contour lines of the 17.5°C SST and the 0.25 mg m-3 Chl- a concentration. Our findings suggest the convergent oceanographic features (fronts) play significant roles in regulating the distribution and abundance of the western stock of the winter-spring cohort of O. bartramii, which can help people to improve their ability to discover the O. bartramii fishing grounds with higher productivity.

  10. Development of N-layer materials for SNS junction and SQUID applications

    International Nuclear Information System (INIS)

    Zhou, J.P.; McDevitt, J.T.; Jia, Q.

    1997-01-01

    Materials characteristics including water reactivity, oxygen loss, electromigration of oxide ions, and interfacial reactivity problems have plagued attempts to produce reliable and reproducible cuprate SNS superconductor junctions. In an effort to solve some of these formidable problems, new N-layer compounds from the family of R 1-x Ca x Ba 2-y La y Cu 3-z M z O 7-δ (R = Y, Gd and Pr; M = Co, Ni and Zn; 0 2 Cu 3 O 7-δ phase and the modified materials exhibit enhanced durability properties. The compounds have been utilized to make both SNS junctions and SQUID devices

  11. Magnetic moment oscillation in ammonium perchlorate in a DC SQUID-based magnetic resonance experiment

    International Nuclear Information System (INIS)

    Montero, V.; Cernicchiaro, G.

    2008-01-01

    In this work we describe experimental results in which a DC SQUID (superconducting quantum interference device) is used as free induction decay detector. Measurements of a solid ammonium perchlorate (NH 4 ClO 4 ) sample were performed, in zero field, at 4.2 K. Unexpected magnetic moment oscillations were detected at 1.5 kHz. The computation of the magnetic fields suggests that the proton nuclear magnetic resonance may explain the measured resonance, considering reorientation of the ammonium group by quantum tunneling of protons and a magnetic proton dipole-dipole intermolecular interaction model

  12. Sensory, chemical and bacteriological changes during storage of iced squid ( Todaropsis eblanae )

    DEFF Research Database (Denmark)

    Paarup, T.; Sanchez, J.A.; Moral, A.

    2002-01-01

    Aims: To relate sensory shelf-life of iced whole and gutted squid to bacterial growth and chemical changes. Methods and Results: Cooked mantles from whole and gutted individuals were rejected after 10 and 12 days of storage, respectively, due to ammoniacal off-odours. Rate of production of both...... to spoilage through activity in the digestive gland, followed by diffusion of volatile compounds and amines to the mantle. Significance and Impact of the Study: Due to the psychrophilic nature of P. phosphoreum and Pseudoalteromonas sp., spread- plating and low temperature incubation are recommended...

  13. Study on the Formulation of Squid (Loligosp) Nugget Added with Yellow Pumpkin (Curcubitamoschata) Flour

    OpenAIRE

    Nurharyati, Lisa; ', Suparmi; Sari, N Ira

    2017-01-01

    This study aimed to determine the squid nugget formulation with the addition of pumpkin flour. It was evaluated for the organoleptic value and the proximate composition. The method used was an experimental method and designed as non-factorial completely randomized design (CRD). The treatments were addition of pumpkin flour into the mix, consisting of four levels, namely: N0 (without the addition of pumpkin flour), N1 (pumpkin flour 50 g), N2 (pumpkin flour 75 g) and N3 (pumpkin flour 100 g).B...

  14. Studies of Superfluid 3He Confined to a Regular Submicron Slab Geometry, Using SQUID NMR

    International Nuclear Information System (INIS)

    Casey, Andrew; Corcoles, Antonio; Lusher, Chris; Cowan, Brian; Saunders, John

    2006-01-01

    The effect on the superfluid ground state of confining p-wave superfluid 3He in regular geometries of characteristic size comparable to the diameter of the Cooper pair remains relatively unexplored, in part because of the demands placed by experiments on the sensitivity of the measuring technique. In this paper we report preliminary experiments aimed at the study of 3He confined to a slab geometry. The NMR response of a series of superfluid samples has been investigated using a SQUID NMR amplifier. The sensitivity of this NMR spectrometer enables samples of order 1017 spins, with low filling factor, to be studied with good resolution

  15. Optical extinction of size-controlled aerosols generated from squid chromatophore pigments

    Directory of Open Access Journals (Sweden)

    Sean R. Dinneen

    2017-10-01

    Full Text Available Nanophotonic granules populate the interior of cephalopod chromatophores, contributing to their visible color by selectively absorbing and scattering light. Inspired by the performance of these granules, we fabricated nanostructured aerosols by nebulizing a pigment solution extracted from native squid chromatophores. We determined their optical extinction using cavity ring-down spectroscopy and show how extinction cross section is dependent on both particle concentration and size. This work not only advances the fundamental knowledge of the optical properties of chromatophore pigments but also serves as a proof-of-concept method that can be adapted to develop coatings derived from these pigmentary aerosols.

  16. The Association of Music Experience, Pattern of Practice and Performance Anxiety with Playing-Related Musculoskeletal Problems (PRMP) in Children Learning Instrumental Music

    Science.gov (United States)

    Ranelli, Sonia; Smith, Anne; Straker, Leon

    2015-01-01

    There is evidence supporting the social and cognitive benefits of music education. However aspects of music practice, such as an increase in frequency and intensity of practice, are associated with playing-related musculoskeletal problems in adult musicians, though with limited evidence in children. The aim of this study was to describe the music…

  17. Patient-reported outcomes instruments: bridging the gap between international copyright laws and common practice for developers and users--a case example.

    Science.gov (United States)

    Anfray, Caroline

    2009-12-01

    Copyright laws are intended to protect the rights of authors in their literary, scientific, and artistic works. The recent controversy about the standardized version of the Asthma Quality of Life Questionnaire between Elizabeth Juniper and Eirini Grammatopoulou et al. is an example of the difficulties inherent to copyright faced by developers and users of patient-reported outcome (PRO) instruments. This brief communication presents the basics of international copyright laws (i.e., the Berne Convention), the facts behind the controversy, and our analysis of the case based on our experience as a distributing center of PRO instruments. We conclude that better communication between developers and users would prevent most unfortunate complications and misunderstandings.

  18. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  19. Divided Instruments

    Science.gov (United States)

    Chapman, A.; Murdin, P.

    2000-11-01

    Although the division of the zodiac into 360° probably derives from Egypt or Assyria around 2000 BC, there is no surviving evidence of Mesopotamian cultures embodying this division into a mathematical instrument. Almost certainly, however, it was from Babylonia that the Greek geometers learned of the 360° circle, and by c. 80 BC they had incorporated it into that remarkably elaborate device gener...

  20. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization