WorldWideScience

Sample records for possibly enhanced gd-excretion

  1. Renal enhancement and excretion of the hepatobiliary contrast agent Gd-EOB-DTPA

    International Nuclear Information System (INIS)

    Zangos, S.; Hammerstingl, R.; Mack, M.G.; Straub, R.; Engelmann, K.; Eichler, K.; Vogl, T.J.

    2001-01-01

    Purpose: To evaluate the clinical value of the renal clearance using MR imaging with different doses of gadolinium ethoxybenzyl-DTPA (Gd-EOB-DTPA) in comparison to gadolinium DTPA (Gd-DTPA). Material and Methods: In a double-blind and randomized clinical phase II study. MR imaging at 1.5 T was performed in 61 patients with five different doses of Gd-EOB-DTPA (3, 6, 12.5, 25 and 50 μmol/kg b.w. as a bolus injection). The study protocol comprised T 1 - and T 2 -weighted spin-echo magnetic resonance and two-dimensional fast low-angle shot imaging before and at increasing intervals for up to 45 min after injection of Gd-EOB-DTPA. These images were compared with Gd-DTPA-enhanced imaging (0.1 mmol/kg b. w. as a bolus injection). Results: After bolus injection of the hepatobiliary MR contrast agent Gd-EOB-DTPA a renal elimination was observed. Immediately after the injection of Gd-EOB-DTPA until the eighth minute a corticomedullary enhancement of the kidney was conspicuous. After the fourth minute a contrast enhancement could be seen in the renal pelvis. The best enhancement was noted after 20 minutes in the FLASH GRE and T 1 -weighted images with good pelvicaliceal contrast. After 45 minutes an outflow of Gd-EOB-DTPA into the ureter could be observed. Conclusion: In addition to the hepatobiliary secretion Gd-EOB-DTPA appears useful for the evaluation of renal structures and renal function on account of the renal excretion without diuretic preparation of the patients. (orig.) [de

  2. Visual assessment of biliary excretion of Gd-EOB-DTPA in patients with suspected diffuse liver disease – A biopsy-verified prospective study

    International Nuclear Information System (INIS)

    Norén, Bengt; Dahlström, Nils; Forsgren, Mikael Fredrik; Dahlqvist Leinhard, Olof; Kechagias, Stergios; Almer, Sven; Wirell, Staffan; Smedby, Örjan; Lundberg, Peter

    2015-01-01

    •MR using hepatocyte specific contrast may potentially assess liver function.•Covariance between contrast uptake and histo-pathological scoring of liver fibrosis.•No relationship between visually assessed biliary contrast excretion and fibrosis scoring.•No relationship between visually assessed biliary excretion and contrast uptake parameters. MR using hepatocyte specific contrast may potentially assess liver function. Covariance between contrast uptake and histo-pathological scoring of liver fibrosis. No relationship between visually assessed biliary contrast excretion and fibrosis scoring. No relationship between visually assessed biliary excretion and contrast uptake parameters. To qualitatively evaluate late dynamic contrast phases, 10, 20 and 30 min, after administration of Gd-EOB-DTPA with regard to biliary excretion in patients presenting with elevated liver enzymes without clinical signs of cirrhosis or hepatic decompensation and to compare the visual assessment of contrast agent excretion with histo-pathological fibrosis stage, contrast uptake parameters and blood tests. 29 patients were prospectively examined using 1.5 T MRI. The visually assessed presence or absence of contrast agent for each of five anatomical regions in randomly reviewed time-series was summarized on a four grade scale for each patient. The scores, including a total visual score, were related to the histo-pathological findings, the quantitative contrast agent uptake parameters, expressed as K Hep or LSC-N, and blood tests. No relationship between the fibrosis grade or contrast uptake parameters could be established. A negative correlation between the visual assessment and alkaline phosphatase (ALP) was found. Comparing a sub-group of cholestatic patients with fibrosis score and Gd-EOB-DTPA dynamic parameters did not add any additional significant correlation. No correlation between visually assessed biliary excretion of Gd-EOB-DTPA and histo-pathological or contrast uptake

  3. Visual assessment of biliary excretion of Gd-EOB-DTPA in patients with suspected diffuse liver disease – A biopsy-verified prospective study

    Directory of Open Access Journals (Sweden)

    Bengt Norén

    2015-01-01

    Conclusions: No correlation between visually assessed biliary excretion of Gd-EOB-DTPA and histo-pathological or contrast uptake parameters was found. A negative correlation between the visual assessment and alkaline phosphatase (ALP was found.

  4. A comparison of Gd-BOPTA and Gd-DOTA for contrast-enhanced MRI of intracranial tumours

    International Nuclear Information System (INIS)

    Colosimo, C.; Knopp, M.V.; Barreau, X.; Gerardin, E.; Kirchin, M.A.; Guezenoc, F.; Lodemann, K.P.

    2004-01-01

    A two-centre intra-individual crossover study was performed in 23 patients with suspected high-grade glioma or metastases to assess and compare the safety and enhancement characteristics of two different MRI contrast media (gadobenate dimeglumine, Gd-BOPTA and gadoterate meglumine, Gd-DOTA) at equivalent doses of 0.1 mmol/kg body weight. T1-weighted spin-echo (SE) and T2-weighted fast SE images were obtained before and T1-weighted images 0, 2, 4, 6, 8 and 15 min after injection. T1-weighted images with magnetisation transfer contrast were acquired 12 min after injection. Qualitative assessment by blinded, off-site readers (reader 1: 19 patients; reader 2: 21) and on-site investigators (23) revealed significant (P ≤0.005) overall preference for Gd-BOPTA over Gd-DOTA for contrast enhancement (Gd-BOPTA preferred in 18, 15 and 18 cases; Gd-DOTA in 0, 1 and 1 and no preference in 1, 5 and 4; off-site readers 1 and 2, and on-site investigators, respectively). A similar significant preference for Gd-BOPTA was expressed by off-site readers and on-site investigators for lesion-to-brain contrast, lesion delineation, internal lesion structure, and overall image preference. Quantitative assessment by off-site readers revealed significantly (p<0.05) greater lesion enhancement with Gd-BOPTA than with Gd-DOTA at all times from 2 min after injection. (orig.)

  5. Magnetic resonance imaging of human cerebral infarction: Enhancement with Gd-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Imakita, S.; Nishimura, T.; Naito, H.; Yamada, N.; Yamamoto, K.; Takamiya, M.; Yamada, Y.; Sakashita, Y.; Minamikawa, J.; Kikuchi, H.

    1987-09-01

    Five patients (1 female and 4 males) with cerebral infarction of 4 h to 27 months duration were studied 9 times with magnetic resonance (MR) using Gd-DTPA. Spinecho (SE) MR images (MRI) were obtained before and after the administration of Gd-DTPA, and correlative CT scans were performed on the same day. In 2 cases, 4 h and 27 months after the ictus, there was no enhancement with Gd-DTPA. There was faint enhancement in 2 cases with cerebral infarction of about 24 h duration and obvious enhancement in all cases in the subacute stage. Compared with enhanced CT, MR using Gd-DTPA demonstrated more obvious enhancement of infarcted areas. MR enhancement using Gd-DTPA showed a gradual increase and the accumulated Gd-DTPA in infarcted areas slowly diffused to the periphery. MR enhancement with Gd-DTPA is similar to that of enhanced CT, but may be more sensitive in the detection of blood brain barrier breakdown.

  6. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  7. Usefulness of fat-suppressed Gd-enhanced MR imaging of tongue cancer

    International Nuclear Information System (INIS)

    Murakami, Shumei; Fuchihata, Hajime; Yoon, Sukja; Furukawa, Souhei; Kawai, Tadahiko; Kishino, Mitsunobu

    1999-01-01

    To evaluate the usefulness of the fat suppression technique for magnetic resonance imaging of oral tongue cancer. One hundred and fourteen patients underwent both magnetic resonance imaging (MRI) and computed tomography (CT). All patients were clinically diagnosed as having oral tongue cancer shown to be squamous cell carcinoma histopathologically. We used two types of CT and six types of MRI scanning: plain CT, contrast enhanced CT, conventional T1w, conventional PDw, conventional T2w, fat-suppressed (FATS) T1w, Gd-enhanced conventional T1w, and Gd-enhanced FATS T1w images. The focus of our study was Gd-enhanced FATS T1w imaging. Tumor detection rates were as follows: Gd-enhanced FATS T1w MRI, 86.8%; conventional T2w MRI, 71.9%; conventional PDw MRI, 65.8%; Gd-enhanced conventional T1w MRI, 47.4%; contrast enhanced CT, 36.8%; T1w MRI, 20.2%; CT, 10.5%. There were 59 cases in which tumors were detected by Gd-enhanced FATS T1w MRI but not detected by contrast enhanced CT. Gd-enhanced FATS T1w MRI was the best for the tumor detection and Gd-enhanced conventional T1w MRI was not useful in the diagnosis of the tongue cancer. CT imaging must not be the first choice for tumor detection in tongue cancer patients. (author)

  8. Gd-DTPA-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Frank, J.A.; Choyke, P.L.; Carvlin, M.; Inscoe, S.; Austin, H.; Dwyer, A.J.; Girton, M.; Black, J.

    1988-01-01

    This paper describes dynamic enhanced renal MR imaging, a new method of identifying specific derangements in renal function. Various diuretics were employed in 45 animal experiments to demonstrate the effects on the normal renal enhancement pattern (EP) after Gd-DTPA. Since different diuretics, osmotic (O), carbonic anhydrase (CA), and loop (L), are active at different sites, specific EP alterations are observed. Imaging was performed with 32 5.1-second sequential gradient recalled acquisition in a steady state images following a bolus of Gd-DTPA

  9. Experimental evaluation of contrast-enhanced high-reselution MR angiography in the rabbit. Gd-DTPA versus Gd-DTPA polylysin

    International Nuclear Information System (INIS)

    Vogl, T.J.; Hoffmann, Y.; Juergens, M.; Weinmann, H.J.; Muehler, A.; Yucel, S.; Felix, R.

    1996-01-01

    In ten anesthesized rabbits (average weight 4.3 kg) MR angiography was performed using a 1.5 TMR unit (Magnetom SP63; Siemens Erlangen) and a CP head coil. Arterial MRA (FISP 3D TONE, TR/TE=33/8, Flip 20 ) and venous MRA (FLASH 2D, TR/TE=37/10, Flip 60 ) was performed before and after administration of the paramagnetic contrast agents Gd-DTPA (n=5) or Gd-DTPA polylysine (n=5) at a doseage of 0.1 mmol/kg. In all studies the single selections and the MIP reconstructions were evaluated quantitatively by measuring and calculating signal intensity, percentage enhancement, signal-to-noise and contrast-to-noise ratios. All studies were assessed qualitatively for visualization and distinction of the arterial and venous vessel system by three independent observers before and after the administration of contrast agent. Results: Gd-DTPA-enhanced arterial FISP 3D tone led to a percentage enhancement of 30% for the kidneys, 12% for the superior mesenteric artery, 18% for the deep circumfluent iliac artery, and 7% for the internal iliac artery. In FLASH 2D sequences Gd-DTPA led to a good C/N only for venous abdominal vessels like the left renal vein (2.59) and internal iliac vein (1.66); the percentage enhancement of these structures was between 16 and 21%. Qualitative comparison also showed no significant improvement after injection of Gd-DTPA. In FISP 3D TONE sequences Gd-DTPA polylysine led to a strong percentlage enhancement of right and left kidney (21 and 40%) and deep circumfluent iliac artery (17%). Qualitative evaluation showed improved delineation and contrast of low-diameter vessels, while the soft tissue was only slightly enhanced and did not impair vessel visualization. Conclusion: CMRA using Gd-DTPA and Gd-DTPA polylysine significantly improved the delineation of abdominal vessels, with Gd-DTPA polylysine being superior. (orig.) [de

  10. Gd-DTPA enhanced MRI of the brain infarction: correlation between onset of infarction and enhancing patterns

    International Nuclear Information System (INIS)

    Joo, An Young; Kim, Myung Soon; Lee, Sung Soo

    1994-01-01

    To evaluate the correlation between onset of brain infarction and Gd-DTPA enhancing patterns on MRI. We reviewed MRI of 58 lesions in 45 patients with clinically documented brain infarction retrospectively. Axial, coronal and sagittal T1WI (TR/TE 450-520/20), T2WI (TR/TE 2190/90) and Gd-DTPA enhanced T1WI were performed with a 0.5T superconductive MR system. We analyzed Gd-enhancing patterns that were divided into intravascular, meningeal, and parenchymal enhancement. Parenchymal pattern was subdivided into mottled, partial ring like and dense enhancement. Intravascular enhancement was seen at 1-10 days in 30(53%) of 58 infarctions. Meningeal enhancement (13%) was noted at 1-6 days. Parenchymal enhancement (50%) was seen at 2-28 days and subdividing patterns are as follows: The mottled enhancement pattern was seen earlier at 2-8 days and partial ring like or dense enhancement patterns at 5-28 days. After reviewing Gd-enhanced MRI of infarction, the intravascular and meningeal enhancement patterns were earlier than parenchymal enhancement. Among parenchymal patterns, the mottled pattern was seen earlier than partial ring like or dense patterns. In conclusion, Gd-enhancing patterns of brain infarction are useful in estimating the age of infarction including acute infarction

  11. Basivertebral plexus enhancement at MR imaging after Gd-DTPA administration

    International Nuclear Information System (INIS)

    Bronstein, A.D.; Cohen, W.A.; Maravilla, K.R.

    1989-01-01

    This paper presents a study to identify noncontrast versus post-Gd-DTPA MR images of the spine, we analyzed the basivertebral plexus. The authors postulate that there are consistent patterns of enhancement specific with Gd-DTPA. This is a retrospective examination of the normal appearance and enhancement patterns of the basivertebral plexus in 805 vertebrae of 30 patients who underwent pre- and post-Gd-DTPA T1-weighted sagittal MR imaging of the spine. All patients show enhancement of the basivertebral plexus in a significant number of vertebrae when pre-and postcontrast images are compared

  12. Recurrent medulloblastoma: Frequency of tumor enhancement on Gd-DTPA MR imaging

    International Nuclear Information System (INIS)

    Rollins, N.; Mendelsohn, D.; Mulne, A.; Barton, R.; Diehl, J.; Reyes, N.; Sklar, F.

    1990-01-01

    Thirty-two children with medulloblastoma were evaluated postoperatively with conventional and gadolinium-enhanced MR imaging. Eleven patients had abnormal cranial MR studies; nine of these had recurrent tumor. In six patients recurrent tumor enhanced with Gd, while in the other three patients recurrent tumor did not enhance. The remaining two patients had areas of abnormal Gd enhancement that were caused by radiation-induced breakdown of the blood-brain barrier rather than by recurrent tumor. This study shows that not all recurrent medulloblastoma enhances and that the absence of Gd enhancement does not necessarily indicate the absence of recurrent tumor

  13. MRI contrast enhancement of the lung using a Gd-DTPA aerosol

    International Nuclear Information System (INIS)

    Bockisch, A.; Harvey, R.C.; Davis, M.A.; Kabalka, G.W.

    1993-01-01

    A MR imaging study was performed in anesthetized female beagle dogs to investigate the effectiveness of Gd-DTPA aerosol for contrast enhancement in ventilated lungs. Ventilation was performed using a commercially available atomizer to administer Gd-DTPA solution. MR imaging was performed with a 1.9 T whole body imager using respiratory gated acquisition. To define the amount of Gd-DTPA being trapped in the lungs identical experiments were performed with 99m Tc-DTPA. MR imaging confirmed at 70% contrast enhancement following inhalation of Gd-DTPA. Because of the inherently low signal intensity of lung parenchyma the degree of contrast enhancement is not sufficient for clinical application. (orig.) [de

  14. Value of the Gd-DTPA contrast enhanced MR in patients with failed back surgery syndrome

    International Nuclear Information System (INIS)

    Paprzycki, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M.

    1994-01-01

    Gd-DTPA contrast - enhanced MR enables differentiation between postoperative scar and recurrent prolapse of nucleus pulposus (RPNP). Pre- and post-contrast MR studies in 40 patients with failed back surgery syndrome, previously treated surgically on 54 intervertebral levels, were evaluated. Presence of RPNP was confirmed on 4, postoperative scars on 35 and both condition on 15 invertebral levels. Correct interpretation of pathologic changes on 15 invertebral levels (28%) was only possible after contrast enhancement. Contrast enhancement of scar excluded the diagnosis of coexistence of RPNP and scar, based on pre-contrast MR studies. MR with Gd-DTPA contrast enhancement is the best diagnostic method in patients with failed back surgery syndrome (author)

  15. MR enhancement of epidural fibrosis by Gd-DTPA: Biodistribution and mechanism

    International Nuclear Information System (INIS)

    Ross, J.S.; Delamater, R.; Van Dyke, C.W.; Masaryk, T.J.; Hueftle, M.G.; Bohlman, H.; Modic, M.T.

    1987-01-01

    Epidural lumbar fibrosis was induced in eight beagle dogs at the L-6 level. Vascular injection with india ink showed abundant vessels in the scar. This agreed with light microscopy in eight patients with epidural fibrosis, which enhanced with Gd-DTPA from a clinical trial. Electron microscopy of epidural scar in humans and dogs demonstrated a continuous endothelium with scattered tight junctions. Biodistirbution was determined in four dogs with rapid MR scanning following intravenous (IV) bolus of 0.1 mmol/kg of Gd-DTPA and radioassay of tissue samples following Gd-153-DTPA IV injection. Maximum percent enhancement (70% humans, 100% dogs) occurred at 3-6 minutes in epidural fibrosis with a slow decline in enhancement over the next hour. These findings suggest that Gd-DTPA enhancement of epidural fibrosis is via an extracellular distribution within vascularized scar tissue

  16. Gd-DTPA MR imaging enhancement of spinal cord tumors

    International Nuclear Information System (INIS)

    Dillon, W.P.; Bolla, K.; Mark, A.S.; Tsudura, J.S.; Norman, D.; Newton, T.H.

    1987-01-01

    Nineteen patients with suspected spinal cord tumors were imaged with T1- and T2-weighted sequences before and after the administration of Gd-DTPA (0.1 mmol/kg). Eleven of the 19 patients had spinal cord tumors (three unproven). Eight of 11 patients had intramedullary tumors (four astrocytomas, two ependymomas) and two had extra-medullary tumors (one meningioma, one metastatic melanoma). Other lesions studied include idiopathic syringomyelia (two), spinal arteriovenous malformation (AVM) (one), posttraumatic arachnoiditis (one), and cord infarct (one). All of the tumors enhanced after the administration of Gd-DTPA. Spinal cord enhancement was also noted in association with a spinal cord AVM, a suspected cord infarct, and in the patient with severe arachnoiditis. No enhancement was present in patients with idiopathic or posttraumatic syringomyelia or in the three normal patients. In six of the patients, enhancement was critical in confirming disease that was questionable on the precontrast MR images. Gadolinium enhancement allowed differentiation of tumor from postoperative changes in two patients with spinal cord tumors. Enhanced images localized the lesion more accurately than precontrast MR images in eight patients. In four patients a lesion could only be detected after the administration of contrast. The postcontrast images better defined the margin of tumor from surrounding edema, operative scarring, and cord cavitation. The AVM case had enhancement of slowly flowing veins with Gd-DTPA posterior to an ischemic cord segment. Gd-DTPA enhancement is extremely useful in the detection and therapeutic assessment of spinal cord tumors; however, enhancement is not specific for tumors and should be interpreted in light of the clinical setting

  17. Phantom and animal studies of a new hepatobiliary agent for MR imaging: comparison of Gd-DTPA-DeA with Gd-EOB-DTPA.

    Science.gov (United States)

    Yoshikawa, Kohki; Inoue, Yusuke; Akahane, Masaaki; Shimada, Morio; Itoh, Sayaka; Seno, Atsushi; Hayashi, Sanshin

    2003-08-01

    To investigate the characteristics of Gd-DTPA-DeA as a hepatobiliary contrast agent for MR imaging in comparison with those of Gd-EOB-DTPA. We undertook phantom experiments to assess T1 relaxivity for Gd-DTPA-DeA, Gd-EOB-DTPA, and Gd-DTPA in human plasma. For Gd-DTPA-DeA and Gd-EOB-DTPA, we evaluated the contrast effect in rats using an SPGR sequence. The contrast ratios of liver and abdominal aorta were measured up to 21 minutes after intravenous administration of the agents. Visualization of the bile duct and renal pelvis was also assessed. In human plasma, T1 relaxivity was similar for Gd-DTPA-DeA and Gd-EOB-DTPA, and higher than those for Gd-DTPA. Whereas the contrast ratio of liver peaked about five minutes after the injection of Gd-EOB-DTPA and was followed by a subsequent decline, a continuous rise was shown for Gd-DTPA-DeA, resulting in a larger maximal contrast effect. Contrast ratios of the abdominal aorta were larger for Gd-DTPA-DeA. Biliary excretion was observed for both agents but occurred earlier with Gd-EOB-DTPA. While renal excretion was shown for all rats three minutes after the injection of Gd-EOB-DTPA, it was not observed for Gd-DTPA-DeA. Gd-DTPA-DeA may be used as a hepatobiliary contrast agent and shows different pharmacokinetics from Gd-EOB-DTPA. Copyright 2003 Wiley-Liss, Inc.

  18. Efficacy of Gd-DTPA-enhanced MRI in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Okamoto, Shinya; Aoki, Toshikazu; Konishi, Tokuji; Nakano, Takeshi; Yamakado, Kyoichiro; Sakuma, Hajime; Takeda, Kann; Nakagawa, Takashi

    1991-01-01

    The cabability of magnetic resonance (MR) imaging to detect tissue characterization or myocardial degeneration process of the hypertrophied myocardium was evaluated in 15 patients with hypertrophic cardiomyopathy. T1-weighted MR images were obtained with a 1.5 T MR unit by using ECG-gated spin-echo techniques. MR images were visually reviewed before and after enhancement of Gd-DTPA. Four patients had an increase in signal intensity mainly in the endocardium of the left ventricular septum on non-enhanced MR images, 3 of whom had widespread high intensity in addition to two-thirds of the wall. Gd-DTPA enhanced-MR images showed high intensity over the whole septum in 5 patients and also in the antero-lateral endocardium in 4 patients. Decreased intensity on non-enhanced MR images, as shown in 4 patients, became clear on enhanced-MR images. According to findings on enhanced-MR images, signal intensity was defined as normal (N), septum (S), and diffuse (D). Patients in Group D tended to be younger and have more frequently family history. Regarding both interventricular septum thickness and left ventricular posterior wall thickness, there was no significant difference among the three groups. Both left ventricular diastolic diameter and left ventricular systolic diameter were significantly larger in Group D than the other two groups. Left ventricular ejection fraction was significantly lower in both Group S and Group D. Widespread abnormal intensity on Gd-DTPA enhanced MR images was associated with findings similar to dilated cardiomyopathy, such as dilated left ventricular lumen and decreased ejection fraction. Gd-DTPA enhanced MR imaging seemed to be useful for visualizing myocardial degeneration in hypertrophic cardiomyopathy.(N.K.)

  19. Gd-BOPTA-enhanced excretory MR urography without administration of diuretics

    International Nuclear Information System (INIS)

    Allkemper, T.; Tombach, B.; Heindel, W.

    2001-01-01

    Purpose: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. Method: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after iv. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance trademark ) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. Results: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. Conclusion: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses. (orig.) [de

  20. MRI contrast enhancement of the lung using as Gd-DTPA aerosol

    International Nuclear Information System (INIS)

    Bockisch, A.; Harvey, R.C.; Davis, M.A.; Kabalka, G.W.

    1993-01-01

    The efficacy of a Gd-DTPA aerosol to enhance ventilated lung parenchyma was evaluated in an MR study in anesthetized female beagle dogs. Ventilation of a 1.0-M Gd-DTPA solution was performed using a commercially available atomizer. MR imaging was performed at a 1.9 T whole body imager with an acquisition mode that was gated to respiration. To quantify the amount of ventilated Gd-DTPA experiments were repeated with 99m Tc-DTPA under identical conditions. Using ventral and dorsal digital scintigraphy, the amount of Gd-DTPA in both lungs were determined. MR imaging showed on increase of signal intensity of 70% following Gd-DTPA ventilation. Because of the inherently low signal intensity of lung parenchyma this degree of contrast enhancement is too small to be clinically useful. (orig.) [de

  1. Hepatic enhancement on Gd-BOPTA-enhanced MR imaging: comparison between cirrhotic and normal livers

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Jeong, Yong Yeon; Kang, Heoung Keun; Lim, Hyo Soon; Yoon, Woong; Seo, Jeong Jin; Park, Jin Gyoon

    2004-01-01

    To compare the enhancement features of hepatic parenchyma between cirrhotic and normal liver, using Gd-BOPTA-enhanced delayed MR imaging. The 60 patients (35 with cirrhotic and 25 with normal liver) included in our study underwent Gd-BOPTA-enhanced MR imaging using a 1.5T system with a phase-array multicoil. In all cases, T1-weighted in-phase and opposed-phase gradient-echo MR imaging was performed before and 60 minutes after intravenous administration of a bolus of Gd-BOPTA. All images were quantitatively analysed by comparing the signal-to-noise ratio (SNR) and signal enhancement (SE) of cirrhotic and normal liver before and after contrast enhancement, and in cirrhotic patients, SNR and SE were also compared in terms of the Child-Pugh classification. For qualitative analysis, the hepatic enhancement patterns of cirrhotic and normal liver were classified as homogeneous or heterogeneous according to the consensual findings of two radiologists. At contrast-enhanced imaging, both cirrhotic (p<0.001) and normal liver (p<0.001) showed substantially increased SNR relative to unenhanced images, and the SNR of cirrhotic liver was significantly lower than that of normal livers at both in-phase (p<0.001) and opposed-phase (p<0.001) imaging. The SE of cirrhotic liver was significantly lower than that of normal liver (in-phase:p=0.002; opposed phase:p=0.011). Both Child-Pugh class A (p<0.001) and B (p<0.001) cirrhotic liver showed a substantial increase in SNR at contrast-enhanced imaging relative to unenhanced imaging and the SNR of Child-Pugh class A was significantly higher than that of Child-Pugh class B at both in-phase (p<0.001) and opposed-phase (p=0.022) imaging. In addition, the SE of class A was significantly higher than that of class B at in-phase imaging (p=0.004). Cirrhotic liver showed heterogeneous enhancement in 20 of 35 patients (57%), whereas normal liver showed homogeneous enhancement in all patients. At Gd-BOPTA-enhanced delayed MR imaging, cirrhotic liver

  2. Evaluation of the MRI with Gd-DTPA enhancement in the diagnosis of brain and spinal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Keiji; Sadamoto, Kazuhiko; Miki, Hitoshi; Sakaki, Saburo; Matsuoka, Kenzo.

    1988-02-01

    Magnetic resonance (MR) imaging was performed using saturation recovery (SR), inversion recovery (IR) and spin echo (SE) pulse sequences before and after the injection of 0.1 mmol of gadolinium diethylenetriamine pentaacetic acid dimeglumine (Gd-DTPA) per kilogram of body weight. Forty-two patients with gliomas (8), meningiomas (12), neurinomas (5), adenoma (1), craniopharyngioma (1), chordoma (1), malignant lymphomas (2), metastatic brain tumors (2), spinal tumors (4), and other tumors (6) were studied. Contrast enhancement was shown in 35 of the 38 patients with brain tumors and in all those with spinal tumors on T/sub 1/-weighted images. The T/sub 1/ relaxation time was decreased in all of these 39 tumors, while the T/sub 2/ relaxation time showed no definite tendency. No marked side effects were observed following the administration of Gd-DTPA. By using Gd-DTPA enhancement, it was possible to differentiate the tumor from the peritumoral edema on MRI, although it was difficult to do so on precontrast MRI. Among the various pulse sequences, the SR sequence provides the best diagnostic value with Gd-DTPA enhancement in the shortest examination time for screening brain and spinal tumors.

  3. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  4. Transudative vs exudative pleural effusions: differentiation using Gd-DTPA-enhanced MRI

    International Nuclear Information System (INIS)

    Frola, C.; Cantoni, S.; Turtulici, I.; Leoni, C.; Loria, F.; Gaeta, M.; Derchi, L.E.

    1997-01-01

    The aim of this study was to investigate the capability of Gd-DTPA-enhanced MRI to differentiate between exudative and transudative pleural effusions. An MRI examination was performed on 22 patients with different types of pleural effusion (10 transudative and 12 exudative effusions). T1-weighted SE images were obtained before and 20 min after administration of Gd-DTPA (0.1 mmol/kg). The degree of enhancement of pleural effusions was evaluated both by visual assessement and by quantitative analysis of images. None of 10 transudative effusions showed significative enhancement, whereas 10 of 12 exudative effusions showed enhancement (sensitivity 83 %, specificity 100 %, positive predictive value 100 %). The postcontrast signal intensity ratios (SIRs) of exudates were significantly higher than corresponding precontrast ratios (P = 0.0109) and the postcontrast SIRs of exudates were significantly higher than those of transudates (P = 0.0300). Exudative pleural effusions show a significant enhancement following administration of Gd-DTPA. We presume that this may be caused by increased pleural permeability and more rapid passage of a large amount of Gd-DTPA from the blood into the pleural fluid in case of exudative effusions. In our limited group of patients, signal enhancement proved the presence of an exudative effusion. Absence of signal enhancement suggests a transudate, but does not exclude an exudate. (orig.). With 5 figs., 2 tabs

  5. Detection of hepatocellular carcinoma: comparison of Gd-DTPA- and ferumoxides-enhanced MR imaging

    International Nuclear Information System (INIS)

    Simon, G.; Link, T.M.; Daldrup-Link, H.; Settles, M.; Woertler, K.; Doebereiner, F.; Schulte-Frohlinde, E.; Rummeny, E.J.

    2005-01-01

    The aim was to compare the diagnostic performance of dynamic Gd-DTPA- and ferumoxides-enhanced MRI for hepatocellular carcinoma (HCC). Twenty-five patients with chronic hepatitis or liver cirrhosis underwent both dynamic gadopentetate- and ferumoxides-enhanced MRI studies of the liver for HCC detection on the same day. MR data of both studies were retrospectively and independently analyzed. Two observers determined in consensus the grade of diffuse fibrotic liver changes (mild, moderate or severe) and the number of focal lesions. HCCs were confirmed by histology (n=22) and/or follow-up studies for at least six months (n=64). Differences in results obtained from both MR data sets were tested for significance with the McNemar's test (p 0.05) and Gd-DTPA-enhanced scans (94.2%). Gd-DTPA- and ferumoxides-enhanced MRI perform equally well for HCC detection. The majority of small hypervascular hepatic lesions, detected on dynamic Gd-DTPA-enhanced MRI but not on ferumoxides-enhanced MRI, represent no HCCs. (orig.)

  6. Gd-DTPA-enhanced MR imaging in meningitis

    International Nuclear Information System (INIS)

    Han, M.H.; Chang, K.H.; Roh, J.K.; Kim, I.O.; Han, M.C.; Kim, C.W.

    1988-01-01

    Gd-DPTA-enhanced MR imaging was performed in 16 patients with meningitis (seven tuberculous, four bacterial, three fungal, and two viral) on a 2.0-T unit. Hemorrhagic infarcts of basal ganglia and localized enhancement of thickened dura adjacent were demonstrated on T1-weighted images in three patients with tuberculous meningitis and four with bacterial meningitis, respectively, that were not seen on CT. Enhanced T1-weighted images readily differentiated leptomeningeal enhancement from vessels in two cases with CT of equivocal meningeal enhancement. Nonenhanced T2-weighted images were most sensitive for demonstrating ischemia/infarct and edema. Otherwise, MR images generally matched CT scans

  7. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    International Nuclear Information System (INIS)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J.

    1995-01-01

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one

  8. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J. [Wallace Memorial Baptist Hospital, Busan (Korea, Republic of)

    1995-05-15

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one.

  9. Labyrinthine enhancement of Gd-MR in patients with sudden hearing loss and vertigo

    International Nuclear Information System (INIS)

    Seltzer, S.; Mark, A.S.; Chapman, J.C.; Nelson-Drake, J.

    1989-01-01

    In the past, no definitive diagnostic study was available to assess causes of sudden-onset hearing loss and vertigo. Our observations have led to an interesting new finding: labyrinthine enhancement on Gd-enhanced MR imaging in four patients with sudden unilateral hearing loss and/or vertigo. MR findings were correlated with audiologic and vestibular studies. All patients were studied with T2-weighted axial images through the whole brain and with Gd-DTPA-enhanced, 3-mm, axial, T1-weighted images through the temporal bone. No labyrinthine enhancement was seen in 20 control patients referred for other clinical problems. Gd-MR imaging might be able to distinguish patients with retrocochlear lesions from those in whom the abnormal process is in the labyrinth or is intraaxial

  10. Synergistic effect of Al and Gd on enhancement of mechanical properties of magnesium alloys

    Directory of Open Access Journals (Sweden)

    Bita Pourbahari

    2017-04-01

    Full Text Available The effect of Gd/Al ratio on the properties of as-cast Mg-Gd-Al-Zn alloys was investigated by changing the chemical composition from that of AZ61 to GZ61. At the ratio of 1, the Al2Gd phase becomes predominant and Mg17Al12 is hardly seen in the microstructure. As a potent inoculant, the Al2Gd phase resulted in intense grain refinement and enhancement of strength, ductility and toughness. For instance, the tensile strength and elongation to failure of Mg-3Gd-3Al-1Zn alloy were enhanced by ~4% and 180% compared with those of AZ61 alloy, respectively. However, at high Gd/Al ratios, the Al2Gd phase was replaced by (Mg,Al3Gd and Mg5Gd phases and very large grain sizes were achieved, which led to poor tensile properties and the appearance of cleavage facets on the fracture surfaces. Therefore, it can be deduced that the presence of Gd and Al, in appropriate amounts to reach Gd/Al ratio of ~ 1, is required for the achievement of grain refinement, good ductility, high strength, and the appearance of ductile fracture surfaces in the Mg-Gd-Al-Zn system. Conclusively, the Mg-Gd-Al-Zn alloys can be considered as a new class of structural magnesium alloy and it is superior to both AZ (Mg-Al-Zn and GZ (Mg-Gd-Zn series of alloys.

  11. Gd-BOPTA-enhanced excretory MR urography without administration of diuretics; Gd-BOPTA-gestuetzte MR-Ausscheidungsurographie ohne Diuretikagabe

    Energy Technology Data Exchange (ETDEWEB)

    Allkemper, T.; Tombach, B.; Heindel, W. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie

    2001-02-01

    Purpose: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. Method: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after iv. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance {sup trademark}) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. Results: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. Conclusion: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses. (orig.) [German] Ziel: Abschaetzung der Durchfuehrbarkeit und des klinischen Nutzens der Gd-BOPTA-gestuetzten MR-Ausscheidungsurographie (MRU) ohne zusaetzliche Diuretikagabe im Vergleich zur konventionellen Ausscheidungsurographie. Methoden: 15 Patienten mit Beckentumoren wurden praeoperativ an einem 1.5 T-Ganzkoerpersystem mit Hilfe einer atemgehaltenen, hochaufloesenden 3D-FLASH-Sequenz unmittelbar nach intra-venoeser Applikation von 0,05 mmol/kg KG Gd-BOPTA (MultiHance {sup

  12. Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, Cesare [Univ. Annunzio, Chieti (Italy). Dept. of Clinical Sciences; Demaerel, Philippe [Univ. Hospital Leuven (Belgium); Tortori-Donati, Paolo [Inst. Gaslini, Genoa (Italy); Christophe, Catherine [Hopital Universitaire des Efants, Brussels (Belgium); Buchem, Mark van [Univ. Hospital Leiden (Netherlands); Hoegstroem, Barry; Pirovano, Gianpaolo; Shen, Ningyan; Spinazzi, Alberto [Worldwide Medical Affairs, Bracco Diagnostics, Inc., Princeton, NJ (United States); Kirchin, Miles A. [Worldwide Medical Affairs, Bracco Imaging SpA, Milan (Italy)

    2005-05-01

    Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to post-dose changes in lesion visualization were significantly better for Gd-BOPTA for both lesion level (2.68{+-}2.17 vs. 1.05{+-}1.90, P=0.0106) and patient level (2.55{+-}2.18 vs. 1.14{+-}1.68, P=0.0079) comparisons. The mean pre-dose to post-dose change in CNR was greater for Gd-BOPTA (9.13{+-}15.36) than Gd-DTPA (2.18{+-}9.90), but the difference was only marginally significant (P=0.0779; 95% CI: -0.553, 14.454) because of wide variations of signal intensity between lesions. Similar findings were obtained for LBR and per cent enhancement. No differences between the agents were noted in terms of safety parameters. (orig.)

  13. Gd-DTPA-enhanced MR imaging of avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Van de Berg, B.; Malghem, J.; Noel, H.; Maldague, B.

    1990-01-01

    This paper evaluates the interest of Gd-DTPA-enhanced MR imaging in the diagnosis of avascular necrosis (AVN) of the hip. MR imaging of 10 patients with various stages of AVN of the femoral head (14 abnormal hips) was performed (1.5-T Gyroscan). T1-weighted images before and after contrast injection and T2-weighted images were obtained in two planes. MR images were compared with pathologic findings in six femoral head specimens (total hip replacement). In the early stages of AVN (Mitchell classes A and B), a peripheral band of contrast-enhanced tissue appears on T1-weighted images after Gd-DTPA injection, mimicking the double line seen on T2-weighted images. In later stages (class C and D), the sequestrated segments, appearing hypointense on T1-weighted images, usually show a significant signal intensity enhancement after Gd-DTPA injection. The truly avascular areas may be limited to a band of thickened subchondral bone

  14. Efficacy of liver parenchymal enhancement and liver volume to standard liver volume ratio on Gd-EOB-DTPA-enhanced MRI for estimation of liver function

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tomohide; Fukukura, Yoshihiko; Kamimura, Kiyohisa; Takumi, Koji; Umanodan, Aya; Nakajo, Masayuki [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Radiology, Kagoshima City (Japan); Ueno, Shinichi [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Surgical Oncology and Digestive Surgery, Kagoshima City (Japan)

    2014-04-15

    We aimed to develop and assess the efficacy of a liver function index that combines liver enhancement and liver volume to standard liver volume (LV/SLV) ratio on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced MRI. In all, 111 patients underwent a Gd-EOB-DTPA-enhanced MRI, including T1 mapping, before and 20 min after Gd-EOB-DTPA administration. We calculated the following Gd-EOB-DTPA-enhanced MRI-based liver function indices: relative enhancement of the liver, corrected enhancement of the liver-to-spleen ratio, LSC{sub N}20, increase rate of the liver-to-muscle ratio, reduction rate of T1 relaxation time of the liver, ΔR1 of the liver and K{sub Hep}; the indices were multiplied by the LV/SLV ratio. We calculated the correlations between an indocyanine green (ICG) clearance and the Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio, by using Pearson correlation analysis. There were significant correlations between all Gd-EOB-DTPA-enhanced MRI-based liver function indices and ICG clearance (r = -0.354 to -0.574, P < 0.001). All Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio (r = -0.394 to -0.700, P < 0.001) were more strongly correlated with the ICG clearance than those without multiplication by the LV/SLV ratio. Gd-EOB-DTPA-enhanced MRI-based liver function indices that combine liver enhancement and the LV/SLV ratio may more reliably estimate liver function. (orig.)

  15. Primed infusion with delayed equilibrium of Gd.DTPA for enhanced imaging of small pulmonary metastases.

    Science.gov (United States)

    Kalber, Tammy L; Campbell-Washburn, Adrienne E; Siow, Bernard M; Sage, Elizabeth; Price, Anthony N; Ordidge, Katherine L; Walker-Samuel, Simon; Janes, Sam M; Lythgoe, Mark F

    2013-01-01

    To use primed infusions of the magnetic resonance imaging (MRI) contrast agent Gd.DTPA (Magnevist), to achieve an equilibrium between blood and tissue (eqMRI). This may increase tumor Gd concentrations as a novel cancer imaging methodology for the enhancement of small tumor nodules within the low signal-to-noise background of the lung. A primed infusion with a delay before equilibrium (eqMRI) of the Gd(III) chelator Gd.DTPA, via the intraperitoneal route, was used to evaluate gadolinium tumor enhancement as a function of a bolus injection, which is applied routinely in the clinic, compared to gadolinium maintained at equilibrium. A double gated (respiration and cardiac) spin-echo sequence at 9.4T was used to evaluate whole lungs pre contrast and then at 15 (representative of bolus enhancement), 25 and 35 minutes (representative of eqMRI). This was carried out in two lung metastasis models representative of high and low tumor cell seeding. Lungs containing discrete tumor nodes where inflation fixed and taken for haematoxylin and eosin staining as well as CD34 staining for correlation to MRI. We demonstrate that sustained Gd enhancement, afforded by Gd equilibrium, increases the detection of pulmonary metastases compared to bolus enhancement and those tumors which enhance at equilibrium are sub-millimetre in size (<0.7 mm(2)) with a similar morphology to early bronchoalveolar cell carcinomas. As Gd-chelates are routinely used in the clinic for detecting tumors by MRI, this methodology is readily transferable to the clinic and advances MRI as a methodology for the detection of small pulmonary tumors.

  16. Gd-EOB-DTPA-enhanced magnetic resonance imaging features of hepatic hemangioma compared with enhanced computed tomography

    OpenAIRE

    Tateyama, Akihiro; Fukukura, Yoshihiko; Takumi, Koji; Shindo, Toshikazu; Kumagae, Yuichi; Kamimura, Kiyohisa; Nakajo, Masayuki

    2012-01-01

    AIM: To clarify features of hepatic hemangiomas on gadolinium-ethoxybenzyl-diethylenetriaminpentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) compared with enhanced computed tomography (CT).

  17. Evaluation of meningeal enhancement with Gd-DTPA

    International Nuclear Information System (INIS)

    Phillips, M.; Ryals, T.J.; Yuh, W.T.C.; Kambho, S.

    1989-01-01

    Forty-three consecutive patients (16 with tumor, 11 with inflammation, 16 postoperative) with abnormal meningeal enhancement were studied. Positive pathology was obtained in 75% of tumors and 100% of inflammatory conditions. Pial enhancement was demonstrated in seven of 11 patients with inflammation, four of 16 with tumor, and two of 16 postoperative patients. Diffuse meningeal enhancement was most commonly present with neoplastic and inflammatory etiologies. Localized enhancement predominated in the postoperative population, unless complicated by a subdural hematoma. A nodular appearance was present in two patients with tumor. In conclusion, Gd-DTPA MR imaging is sensitive to but not specific of meningeal pathology. MR imaging is better in inflammatory than in neoplastic conditions

  18. Correlation of emmprin expression in vascular endothelial cells with blood-brain-barrier function: a study using magnetic resonance imaging enhanced by Gd-DTPA and immunohistochemistry in brain tumors.

    Science.gov (United States)

    Sameshima, Tetsuro; Nabeshima, Kazuki; Toole, Bryan P; Inoue, Teruhiko; Yokogami, Kiyotaka; Nakano, Shinichi; Ohi, Takekazu; Wakisaka, Shinichiro

    2003-06-01

    In a previous study, we demonstrated that the expression levels in tumor cells of emmprin (CD147) correlated with the grade of astrocytic tumors. Also, we found that emmprin was expressed in vascular endothelial cells of the non-neoplastic brain and hypothesized that emmprin expression could be associated with normal blood-brain-barrier (BBB) function of vascular endothelial cells. In this study, this possibility was examined in non-neoplastic brain, glioma and metastatic carcinoma tissues by comparing emmprin immunohistochemistry with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) enhancement of magnetic resonance imaging (MRI), which is a clinical indicator of the BBB function. This study included 10 cases of non-neoplastic brain tissues, 7 of metastatic carcinoma, 7 of diffuse astrocytoma, 4 of anaplastic astrocytoma and 13 of glioblastoma multiforme. In all the cases, MRI with administration of Gd-DTPA was performed. The lesions were resected using the microdissection method with the help of ultrasonography and a neuronavigator. The tissues from Gd-DTPA-enhanced or non-enhanced areas were processed into frozen sections and subjected to immunohistochemistry with anti-emmprin antibody. The expression of emmprin in brain vascular endothelial cells inversely correlated with Gd-DTPA-enhancement of MRI: emmprin was positive in tissues not enhanced by Gd-DTPA and was negative in DTPA-enhanced tissues. Since BBB function presumably remains unimpaired in regions in which MR images are not Gd-DTPA-enhanced, emmprin expression appears to be associated with unimpaired BBB function. This is the first report to demonstrate a possible correlation between emmprin expression and BBB function in humans.

  19. MRI enhancement of the facial nerve with Gd-DTPA, 1

    International Nuclear Information System (INIS)

    Yanagida, Masahiro

    1993-01-01

    Although there have recently been numerous reports of enhanced MRI in patients with facial palsy, the mechanism of enhancement remains largely unknown. In the present study, animal models with experimentally induced facial paralysis were prepared, and the vascular permeabilities of normal and damaged facial nerves were assessed using Evans blue albumin (EBA) as a tracer. The Gd-DTPA contents in normal and compressively damaged facial nerves were also investigated. In the normal intratemporal facial nerve, EBA remained in the vessels, and did not leak into the endoneurium. In contrast, vascular permeability was very high in the epineurium and the geniculate ganglion which showed leakage of large amounts of EBA from vessels. At the site of compression in the damaged nerve, EBA leakage was also seen in the endoneurism, indicating accentuated vascular permeability. This accentuation of vascular permeability shifted toward the distal side. However, no EBA leakage was seen on the side proximal to the site of compression. Significantly higher Gd-DTPA contents were obtained in the facial nerve on the paralytic side than in that on the normal side (p<0.001). As for differences between the distal and proximal sides, the distal side had a significantly higher Gd-DTPA content (p<0.01). Assessment of vascular permeability with EBA revealed accentuated vascular permeability on the side distal to the site of compression. These results showed the presence of a blood nerve barrier (BNB) in the facial nerve. Furthermore, the present findings suggest that the enhancement of the facial nerve on the affected side is caused by BNB destruction due to nerve damage and subsequent Gd-DTPA leakage from the vessels. Furthermore, it is suggested that the facial nerve enhancement appears to occur mainly on the distal side of the damaged portion of the nerve. (author)

  20. Hepatic kinetics and magnetic resonance imaging of gadolinium ethoxybenzyl diethylenetriaminepentacetic acid (Gd-EOB-DTPA) in dogs

    International Nuclear Information System (INIS)

    Benness, G.; Khangure, M.; Warwick, A.; Burrows, P.

    1993-01-01

    This complex study was designed to measure the transport and excretion characteristics of gadolinium ethoxybenzyl diethylenetriaminepentacetic acid (Gd-EOB-DTPA) in dog's livers following bolus and infusion. Simultaneous T1 magnetic resonance imaging was performed to measure maximum signal enhancement. Anesthetized dogs had cannulation of the common bile duct and urinary bladder for collections and cannulation of the femoral artery and vein for monitoring, blood sampling and infusion. Gd-EOB-DTPA was administered by bolus (range 12.5-200 μmol/kg) and infusion (range 0.4-6.4 μmol/min per kg). An hepatic transport maximum 0.09-0.15 μmol/min/kg was achieved with a blood concentration of 0.03-0.06 μmol/mL. Marked hepatic affinity for Gd-EOB-DTPA was demonstrated with measurements of liver concentration. Maximum T1 signal enhancement was achieved with blood Gd-EOB-DTPA concentration of 0.02-0.03 μmol/mL and a liver concentration of 1-2 μmol/g. The transport maximum for Gd-EOP-DTPA in the dog was similar to that for ipodate and iodipamide and effective imaging was achieved with sub-maximal doses. The maximum signal enhancement at blood concentrations less than required for maximum transport suggest a wide latitude for effective clinical imaging. 4 refs., 4 tabs., 1 fig

  1. Composition-driven enhanced magnetic properties and magnetoelectric coupling in Gd substituted BiFeO{sub 3} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Vijayasundaram, S.V., E-mail: vijayasundaramsv@gmail.com [Department of Physics, Presidency College, Chennai 600005 (India); Suresh, G. [Department of Physics, Park College of Engineering and Technology, Coimbatore 641659 (India); Department of Urology, Singapore General Hospital, Singapore 169856 (Singapore); Mondal, R.A. [Department of Physics, Hindustan University, Chennai 603103 (India); Kanagadurai, R. [Department of Physics, Presidency College, Chennai 600005 (India)

    2016-11-15

    Bi{sub 1-x}Gd{sub x}FeO{sub 3} (x=0, 0.05 and 0.1) samples were synthesized by modified sol–gel process. X-ray diffraction studies confirmed that the crystal structures of Gd substituted samples remain stable for x<0.1, while compositional-driven structural phase transition from rhombohedral to orthorhombic was observed in the case of x=0.1. The average particle sizes of pure and Gd substituted BiFeO{sub 3} nanoparticles were found to be in the range 62–46 nm. The size of the oblate spherical particles decreased with increasing Gd concentration. XPS studies revealed the trivalent oxidation states of Bi and Fe ions along with sample purity. Pure BiFeO{sub 3} exhibited linear M–H loop indicating its antiferromagnetic characteristics, whereas obvious non-linear M–H loops were observed in Gd substituted samples. In contrast to the observed room temperature magnetization (0.36 emu/g) under 40 kOe for BiFeO{sub 3}, the sample with 10% Gd exhibited appreciable enhancement of magnetization (1.88 emu/g). A leaky type P–E hysteresis loop was observed for the pure one, whereas concave-like ferroelectric loops were obtained for Gd substituted samples. The possible origins of enhanced multiferroic properties have been explained on the basis of substituent, its concentration, phase purity, particle size, structural distortion and the modified magnetic structure. The measurement of magnetoelectric studies at room temperature revealed the coupling between magnetic and ferroelectric ordering, which is desirable for multifunctional device applications of multiferroics. - Highlights: • The substitution of Gd in BiFeO{sub 3} (BFO) nanoparticles led to structural distortion. • Average sizes of the substituted samples are less than the spin period of BFO. • Gd-substitution altered the original magnetic structure of BFO (AFM – FM). • M{sub r} of a substituted sample is an order of magnitude higher than that of BFO. • All the samples show magnetoelectric coupling

  2. Quantitative evaluation of enhancement patterns in focal solid liver lesions with Gd-EOB-DTPA-enhanced MRI.

    Directory of Open Access Journals (Sweden)

    Michael Haimerl

    Full Text Available PURPOSE: The objective was to investigate the dynamic enhancement patterns in focal solid liver lesions after the administration of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA by means of dynamic magnetic resonance imaging (MRI including hepatobiliary phase (HP images 20 min after Gd-EOB-DTPA administration. MATERIALS AND METHODS: Non-enhanced T1/T2-weighted as well as dynamic magnetic resonance (MR images during the arterial phase (AP, the portal venous phase (PVP, the late phase (LP, and the HP (20 min were obtained from 83 patients (54 male, 29 female, mean age 62.01 years with focal solid liver lesions. MRI was conducted by means of a 1.5-T system for 63 patients with malignant liver lesions (HCCs: n = 34, metastases: n = 29 and for 20 patients with benign liver lesions (FNH lesions: n = 14, hemangiomas: n = 3, adenomas: n = 3. For quantitative analysis, signal-to-noise ratios (SNR, contrast enhancement ratios (CER, lesion-to-liver contrast ratios (LLC, and signal intensity (SI ratios were measured. RESULTS: The SNR of liver parenchyma significantly increased in each dynamic phase after Gd-EOB-DTPA administration compared to the SNR of non-enhanced images (p<0.001. The CER of HCCs and metastases significantly decreased between LP and HP images (p = 0.0011, p<0.0001. However, FNH lesions did not show any significant difference, whereas an increased CER was found in hemangiomas. The mean LLCs of FNH lesions were significantly higher than those of HCCs and metastases. The LLC values of hemangiomas remained negative during the entire time course, whereas the LLC of adenomas indicated hyperintensity from the AP to the LP. Furthermore, adenomas showed hypointensity in HP images. CONCLUSION: Gd-EOB-DTPA-enhanced MRI may help diagnose focal solid liver lesions by evaluating their enhancement patterns.

  3. The enhancement effects of Gd-DTPA for cerebro-spinal lesions

    International Nuclear Information System (INIS)

    Mano, Isamu; Yoshida, Hideo; Kono, Takeshi; Tsuchida, Takashi; Terao, Hideo; Iio, Masahiro.

    1987-01-01

    Effects of Gadolinium DTPA enhancement in MRI for cerebro-spinal lesions were studied on 20 patients. In this study, pre-contrast T 2 weighted image and the postcontrast T 1 weighted image were, especially, compared. Out of 20 cases investigated, the clinical significance of Gd-DTPA was recognized clearly in 14 cases. In the other 6 cases, some new information, though which did not give us the direct clinical significance, was also obtained. It was confirmed that T 2 weighted sequence without Gd-DTPA was the best in sensitivity, while T 1 weighted sequence after Gd-DTPA administration was superior in specificity of the information in making a discrimination between tumor and edema, gliosis and in the time-course of infarction. (author)

  4. Gd-EOB-DTPA-enhanced-MR imaging in the inflammation stage of nonalcoholic steatohepatitis (NASH) in mice.

    Science.gov (United States)

    Yamada, Tomomi; Obata, Atsushi; Kashiwagi, Yuto; Rokugawa, Takemi; Matsushima, Shuuichi; Hamada, Tadateru; Watabe, Hiroshi; Abe, Kohji

    2016-07-01

    The purpose of this study is to investigate the correlation between the liver kinetics of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) and liver histopathology in a mouse model of NASH by using dynamic contrast-enhanced MRI. Twenty male C57/BL6 mice aged 8weeks were fed a methionine-choline-deficient (MCD) diet for 2, 4 and 6weeks (MCD groups: MCD 2w, 4w, or 6w). Gd-EOB-DTPA-enhanced MR imaging of the liver was performed at 2, 4 and 6weeks after the MCD feeding. The signal intensity of the liver was obtained from dynamic MR images and relative enhancement (RE), and the time to maximum RE (Tmax) and half-life of elimination RE (T1/2) were calculated. After MRI scan, histopathological scores of hepatic steatosis and inflammation and blood biochemistry data, such as aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels, were obtained. Plasma AST and ALT levels were significantly increased in mice fed MCD. Histopathological scores indicated that steatohepatitis progressed with the MCD feeding period from 2 to 6weeks, but significant fibrosis was observed only in mice fed MCD for 6weeks. Gd-EOB-DTPA-enhanced MRI showed that Tmax was significantly prolonged in the livers of the 6-week group compared to the control group (control, 4.0±0.7min; MCD 6w, 12.1±1.6min), although there was no alteration in the 2- and 4-week groups. T1/2 was significantly prolonged in mice fed MCD for 4 and 6weeks compared to the control group (control, 19.9±2.0min; MCD 4w, 46.7±8.7min; MCD 6w, 65.4±8.8min). The parameters of Gd-EOB-DTPA kinetics (Tmax and T1/2) in the liver were positively correlated with the liver histopathological score (steatosis vs Tmax, rho=0.69, P=0.0007; inflammation vs Tmax, rho=0.66, P=0.00155; steatosis vs T1/2, rho=0.77, Pmouse model of NASH, suggesting the possibility of detecting the steatohepatitis stage without fibrosis by Gd-EOB-DTPA-enhanced MR imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Enhancement of intracranial meningeal lesions with Gd-DTPA MR imaging

    International Nuclear Information System (INIS)

    Brown, E.; De La Paz, R.

    1989-01-01

    Pathologic intracranial meningeal enhancement on Gd-DTPA MR images (T1-weighted spin-echo sequence, 800/20 [repetition time msec/echo time msec] 1.5 T) was evaluated in 23 patients. Diagnoses included metastatic neoplasm (13 cases), benign neoplasm (four), infection (one), subarachnoid hemorrhage (three), and subdural hematoma (two). Eleven patients had undergone previous surgery. Diffuse enhancement occurred in 11 patients: eight with malignant infiltration, two with postoperative inflammation, and one with meningitis. Focal enhancement occurred in 12 patients, equally divided between those with malignant and benign processes: six cases were adjacent to intra- or extra-axial malignancy; three were at sites of recent (1--3 weeks) subarachnoid hemorrhage; and three were postoperative, adjacent to a craniotomy or subdural hematoma. Meningeal lesions were rarely diagnosed on the precontrast images, and Gd-DTPA enhancement was needed to distinguish between thickened meninges and thin fluid collections. Precontrast T1- and T2-weighted images were needed to discriminate high-signal meningeal enhancement from subacute subdural or subarachnoid hemorrhage, diploic marrow, normal vascular structures, and benign dural plaques. Meningeal enhancement was not pathology specific, and precontrast images are recommended to avoid misdiagnosis of subacute hemorrhage and misinterpretation of normal anatomy

  6. Gd-DTPA-enhanced MR in thoracic disc herniations

    International Nuclear Information System (INIS)

    Parizel, P.M.; Rodesch, G.; Baleriaux, D.; Segebarth, C.; Zegers de Beyl, D.; Haens, J. d'; Noterman, J.

    1989-01-01

    The Gd-DTPA-enhanced magnetic resonance findings in two patients with herniated thoracic intervertebral discs are reported. The first patient was a 56-year-old woman with a small subligamentous T6-7 disc herniation, slightly lateralized to the right. The second patient was a 51-year-old man with a central and right posterolateral disc herniation, including a large calcified fragment, at the T8-9 level. The nonenhanced MR examination revealed the presence of an extradural mass lesion in both patients, impinging upon the dural sac and compressing and displacing the spinal cord posteriorly. The lesion was slightly hypointense on both T1- and T2-weighted spin echo sequences. Following intravenous injection of Gd-DTPA in a dosage of 0.1 mmol/kg body weight, enhancement of the posterior longitudinal ligament was noted and triangular areas of contrast uptake were seen to occur in the epidural space above and below the herniated disc. At surgery, they were found to correspond to dilated and congested epidural veins. (orig.)

  7. Follow-up of acute myocardial infarction with Gd-DTPA-enhanced MR image

    International Nuclear Information System (INIS)

    Matheijssen, N.A.A.; Dijkman, P.; Rossum, A.C. van der; Laarse, A. van der; Voorthuisen, A. van; Bruschke, A.

    1990-01-01

    MR imaging with Gd-DTPA has been shown to be useful in the identification of acutely infarcted myocardium. The purpose of this paper is to assess the influence of Gd-DTPA on myocardial signal intensity (SI) at different intervals after acute myocardial infarction (SMI). The authors used Gd-DTPA-enhanced MR imaging to study 84 patients at different intervals after AMI. A total of 109 T1-weighted MR studies were performed with a Philips Gyroscan magnet (0.5T) before and 20 minutes after Gd-DTPA (0.15 mmol/kg given intravenously). Four groups were studied. Group 1 underwent MR imaging less than 1 week after AMI; group 2, 1-3 weeks; group 3, 3-6 weeks; and group 4, over 6 weeks after AMI

  8. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  9. Value of Gd-EOB-DTPA-enhanced MRI in assessing liver function

    Directory of Open Access Journals (Sweden)

    WANG Lili

    2015-05-01

    Full Text Available ObjectiveTo explore the value of magnetic resonance imaging (MRI specifically enhanced with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA in assessing the liver function in general population. MethodsUpper abdominal MRI images and Gd-EOB-DTPA-enhanced images, as well as some clinical information, were collected from 41 cases meeting the inclusion and exclusion criteria. Taking the spleen as the control organ, liver-spleen signal intensity contrast (SIliver/spleen and relative liver enhancement (RLE were calculated at 10 min and 20 min after injecting Gd-EOB-DTPA. Differences were evaluated using the independent-samples t-test or Mann-Whitney U test. Corrections were analyzed via Spearman’s rank correlation. ResultsBoth SIliver/spleen at 10 min and 20 min after injection of contrast agent were correlated with Child classification (P<0.05. SIliver/spleen at 20 min had a greater correlation coefficient (r=-0.526 than that at 10 min. The SIliver/spleen with plain scan had no significant correlation with Child classification (P>0.05. RLE at 20 min, but not at 10 min, was correlated with Child classification (r=-0.362, P=0049. Between the cirrhotic and non-cirrhotic groups, SIliver/spleen showed no significant difference (P>0.05. However, SIliver/spleen at 10 min and 20 min, as well as RLE20 min, showed significant differences between the cirrhotic and non-cirrhotic groups (P<0.05. SIliver/spleen at 20 min also exhibited a significant difference between the elevated and normal ALT and TBil groups (both P<0.05. ConclusionGd-EOB-DTPA-enhanced MRI can monitor liver function changes, and SIliver/spleen at 20 min may have an important value in assessing the liver function in general population.

  10. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    Science.gov (United States)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p DTPA-enhanced MRI had a higher

  11. Gd{sub 90}Co{sub 2.5}Fe{sub 7.5} alloy displaying enhanced magnetocaloric properties

    Energy Technology Data Exchange (ETDEWEB)

    Provenzano, V., E-mail: virgil12@nist.gov [Materials Science and Engineering Division, NIST, Gaithersburg, MD 20899-8552 (United States); Shull, R.D., E-mail: robert.shull@nist.gov [Materials Science and Engineering Division, NIST, Gaithersburg, MD 20899-8552 (United States); Kletetschka, G., E-mail: kletetschka@gmail.com [Faculty of Science, Charles University, Prague 12843 (Czech Republic); Institute of Geology, Academy of Science of the Czech Republic, v.v.i., Prague 16500 (Czech Republic); Stutzman, P.E., E-mail: paul.stutzman@nist.gov [Materials and Structural Systems Division, NIST, Gaithersburg, MD 20899-861 (United States)

    2015-02-15

    Highlights: • The Gd{sub 90}Co{sub 2.5}Fe{sub 7.5} alloy displays superior magnetocaloric properties than Gd. • Alloy’s superior properties at relatively low field values: 400, 800 kA/m (0.5, 1 T). • We proposed two possible mechanisms for the Gd-based alloy enhanced properties. • We indicated a pathway for further improving the alloy magnetocaloric properties. - Abstract: We report on the discovery of a new Gd{sub 90}Co{sub 2.5}Fe{sub 7.5} alloy exhibiting superior magnetocaloric properties compared to those of gadolinium. We present magnetically-derived entropy change, ΔS{sub M}, computed from magnetic data, and thermally-derived temperature change, ΔT{sub ad}, obtained from direct thermal measurements together with their respective MCE peaks for the alloy and gadolinium. The MCE peaks of the alloy are taller and broader than the corresponding MCE peaks of gadolinium. Correspondingly, the refrigeration capacity (RC) values of the alloy computed from magnetic and thermal MCEs for field changes, ΔH, of 400 kA/m (0.5 T) and 800 kA/m (1 T) are about 20% larger than those of gadolinium. Two possible mechanisms are proposed to account for the improved magnetocaloric properties of gadolinium alloyed with small amounts of Co and Fe, thereby pointing out a different methodology to use in the search for improved low field magnetic refrigerants.

  12. Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex

    International Nuclear Information System (INIS)

    Brasch, R.C.; Weinmann, H.J.; Wesbey, G.E.

    1984-01-01

    Gadolinium (Gd)-DTPA complex was assessed as a nuclear magnetic resonance (NMR) contrast-enhancing agent by experimentally imaging normal and diseased animals. After intravenous injection, Gd-DTPA, a strongly paramagnetic complex by virtue of unpaired electrons, was rapidly excreted into the urine of rats, producing an easily observable contrast enhancement on NMR images in kidney parenchyma and urine. Sterile soft-tissue abscesses demonstrated an obvious rim pattern of enhancement. A focus of radiation-induced brain damage in a canine model was only faintly detectable on spin-echo NMR images before contrast administration; after 0.5 mmol/kg Gd-DTPA administration, the lesion intensity increased from 3867 to 5590. In comparison, the normal brain with an intact blood-brain barrier remained unchanged in NMR characterization. Gd-DTPA is a promising new NMR contrast enhancer for the clinical assessment of renal function, of inflammatory lesions, and of focal disruption of the blood-brain barrier

  13. Correlation between choline level and Gd-DTPA enhancement in patients with brain metastases of mammary carcinoma

    NARCIS (Netherlands)

    P.E. Sijens (Paul); P. van Dijk (Pieter); M. Oudkerk (Matthijs)

    1994-01-01

    textabstractSingle voxel 1HH double spin-echo MR spectroscopy was used to examine 15 cases of brain metastasis of mammary carcinoma (18 lesions) in relation to Gd-DTPA enhanced MR imaging. For lesions larger than 50% of MRS voxel size, there was significant correlation between Gd-DTPA-enhanced MRI

  14. Value of Gd-EOB-DTPA-enhanced MRI in diagnosis of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    SUN Yu

    2018-01-01

    Full Text Available Objective To investigate the value of Gd-EOB-DTPA-enhanced MRI in the diagnosis of hepatocellular carcinoma (HCC. Methods A total of 40 patients with liver cirrhosis or suspected HCC who visited General Hospital of Shenyang Military Area Command from October 2016 to April 2017 were enrolled, and the data on three dynamic phases of Gd-EOB-DTPA-enhanced MRI (arterial phase, portal venous phase, and delayed phase, hepatobiliary phase (delayed for 20 minutes, and diffusion-weighted imaging (DWI (b=50,400, and 1000 s/mm2 were collected. Two radiologists made a diagnosis and gave diagnostic confidence scores based on the presence or absence of hepatobiliary phase images. Postoperative pathology or clinical diagnosis was used as the criteria for assessing the diagnostic accuracy of HCC. The t-test was used for comparison of continuous data, and the chi-square test was used for comparison of categorical data. Results A total of 42 HCC lesions and 37 cirrhotic nodules were detected. There were significant differences between HCC lesions and cirrhotic nodules in signal intensity on hepatobiliary phase and DWI (χ2=64.503 and 67.855, both P<0.001,as well as the apparent diffusion coefficient when the b-values of DWI were 400 s/mm2 and 1000 s/mm2 (t=62.75 and 75.36, both P<0.001. There was a significant difference in diagnostic confidence score given by the radiologists between the images of three dynamic phases of Gd-EOB-DTPA-enhanced MRI and those of four dynamic phases (including hepatobiliary phase (3.260±0.521 vs 4.620±0.661, t=10.67, P<0.001. With postoperative pathology and clinical diagnosis as criteria, the images of three dynamic phases of Gd-EOB-DTPA-enhanced MRI had a significantly higher diagnostic accuracy for HCC than those of four dynamic phases (including hepatobiliary phase [76.19% (32/42 vs 95.24% (40/42, χ2=6.222, P=0.013]. Conclusion Gd-EOB-DTPA-enhanced MRI may improve diagnostic accuracy and confidence for HCC and has

  15. Gd-EOB-DTPA enhanced MRI of the liver: Correlation of relative hepatic enhancement, relative renal enhancement, and liver to kidneys enhancement ratio with serum hepatic enzyme levels and eGFR

    Energy Technology Data Exchange (ETDEWEB)

    Talakic, Emina; Steiner, Jürgen; Kalmar, Peter; Lutfi, Andre [Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Quehenberger, Franz [Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Auenbruggerplatz 2, 8036 Graz (Austria); Reiter, Ursula; Fuchsjäger, Michael [Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036 Graz (Austria); Schöllnast, Helmut, E-mail: helmut.schoellnast@medunigraz.at [Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036 Graz (Austria)

    2014-04-15

    Objectives: To assess the correlation of relative hepatic enhancement (RHE), relative renal enhancement (RRE) and liver to kidneys enhancement ratio (LKR) with serum hepatic enzyme levels and eGFR in Gd-EOB-DTPA enhanced MRI of the liver and to assess threshold levels for predicting enhancement of the liver parenchyma. Methods: Data of 75 patients who underwent Gd-EOB-DTPA enhanced MRI of the liver were collected. Images were obtained before contrast injection, during the early arterial phase, late arterial phase, venous phase, delayed phase, and hepatobiliary phase which was 20 min after Gd-EOB-DTPA administration. Signal intensity of the liver and the kidneys in all phases was defined using region-of-interest measurements for relative enhancement calculation. Serum hepatic enzyme levels and eGFR were available in all patients. Spearman correlation test was used to test the correlation of RHE, RRE and LKR with serum hepatic enzyme levels and eGFR. Results: In the hepatobiliary phase all serum hepatic enzymes were significantly correlated with RHE; total bilirubin (TBIL) and cholin esterase (CHE) showed strongest correlations. TBIL and CHE were significantly correlated with RRE in the arterial phases. TBIL and CHE were significantly correlated with LKR in the arterial phase and hepatobiliary phase. eGFR showed no correlation. Conclusions: In Gd-EOB-DTPA enhanced MRI, TBIL and CHE levels may predict RHE, RRE and LKR.

  16. MR imaging of spine and spinal canal neoplasms: value of Gd-DTPA contrast enhancement

    International Nuclear Information System (INIS)

    Paprzycki, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M.

    1994-01-01

    Value of Gadolinium-DTPA contrast enhancement in diagnosis of neoplastic diseases of spinal canal was estimated on the basis of retrospective analysis of MR examinations performed in 75 patients. The analyzed material consisted of 15 cases of intramedullary tumors (group 1.), 38 of subdural extramedullary (group 2.) and 22 extradural ones (group 3.). Contrast enhanced MR contributed significant information to the final diagnosis in all groups. The utmost significance of Gd-DTPA contrast enhancement was ascertained in group 1. Authors conclude that contrast enhancement with Gd-DTPA is indispensable in all these cases of spinal canal neoplasms, where non-contrast MR did not reveal pathologic changes in optimal manner. (author)

  17. Diagnostic value of Gd-EOB-DTPA-enhanced MR cholangiography in non-invasive detection of postoperative bile leakage.

    Science.gov (United States)

    Kul, Melahat; Erden, Ayşe; Düşünceli Atman, Ebru

    2017-04-01

    To assess the diagnostic value of dynamic T 1 weighted (T1w) gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA)-enhanced MR cholangiography (MRC) for the detection of active bile leaks. A total of 28 patients with suspected biliary leakage who underwent routine T 2 weighted (T2w) MRC and T1w GD-EOB-DTPA-enhanced MRC at our institution from February 2013 to June 2016 were included in this study. The image sets were retrospectively analyzed in consensus by three radiologists. T1w Gd-EOB-DTPA-enhanced MRC findings were correlated with clinical data, follow-up examinations and findings of invasive/surgical procedures. Patients with positive bile leak findings in Gd-EOB-DTPA-enhanced MRC were divided into hepatobiliary phase (HBP) (20-30 min) and delayed phase (DP) (60-390 min) group according to elapsed time between Gd-EOB-DTPA injection and initial bile leak findings in MRC images. These groups were compared in terms of laboratory test results (total bilirubin, liver enzymes) and the presence of bile duct dilatation in T2w MRC images. In each patient, visualization of bile ducts was sufficient in the HBP. The accuracy, sensitivity and specificity of dynamic Gd-EOB-DTPA-enhanced T1w MRC in the detection of biliary leaks were 92.9%, 90.5% and 100%, respectively (p  0.05). Three patients, each of them in DP group, showed normal laboratory test results and bile duct diameters. Dynamic T1w Gd-EOB-DTPA-enhanced MRC is a useful non-invasive diagnostic tool to detect bile leak. Advances in knowledge: Prolonged DP imaging may be required for bile leak detection even if visualization of biliary tree is sufficient in HBP and liver function tests, total bilirubin levels and bile duct diameters are normal.

  18. Functional dynamic MR imaging and pharmacokinetics of Gd-DTPA in patients with renal failure

    International Nuclear Information System (INIS)

    Krestin, G.P.; Neufang, K.F.R.; Friedmann, G.; Clauss, W.; Schuhmann-Giampieri, G.; Stoeckl, B.

    1989-01-01

    This paper reports excretion of Gd-DTPA analyzed in 20 patients with renal parenchymal disease and decreased creatinine clearance (20-80 mL/min) and compared with excretion in five patients with normal renal function. All 25 underwent a dynamic MR study that employed fast gradient-echo sequences with single images during breath holding. The time between appearance of the contrast agent in the renal cortex and signal intensity drop in the medulla was an indicator of glomerular filtration rate and correlated well with creatinine clearance values. Fractionate urine collection and serum analysis up to 120 hours showed a prolonged but complete (98%) elimination of Gd-DTPA. Renal functional parameters did not change after administration of Gd-DTPA, and no nephrotoxic effects were observed. Thus, MR imaging provides a good quantitative evaluation of the glomerular filtration rate; moreover, administration of Gd-DTPA in patients with renal failure does not impair excretory function and can therefore be safely applied in patients with reduced excretory function

  19. Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution. Gd-EOB-DTPA versus Gd-DTPA in vivo

    International Nuclear Information System (INIS)

    Fujinaga, Yasunari; Tsukahara, Yoshinori; Sugiyama, Yukiko; Kadoya, Masumi; Ueda, Hitoshi; Kitou, Yoshihiro

    2013-01-01

    The purpose of this study was to evaluate the difference in the time-intensity curves (TICs) of the abdominal aorta on dynamic contrast-enhanced MRI (DCE-MRI) between gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) and gadolinium ethoxybenzydiethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Ten healthy volunteers underwent DCE-MRI three times with the following protocol: group A, Gd-DTPA at an injection rate of 3 ml/s; group B, Gd-EOB-DTPA, 3 ml/s; group C, Gd-EOB-DTPA, 1.5 ml/s. Signal intensities (SIs) of the abdominal aorta were measured, and the contrast enhancement ratio (CER) was calculated. Time-to-CER curves were compared among the three groups. The differences in maximum CER (CER max ) and time-to-peak of CER were analyzed. The time-to-CER curve showed a double peak pattern in group A and single-peak pattern in groups B and C. The mean time between the first and the second peak was 6.2 s. The mean CER max of each group was 4.50, 4.52 and 4.27, respectively. In group A, B and C, the mean time-to-peak was 14.6, 10.6 and 12.6 s, respectively. There was a significant difference between group A and B (P<0.01). To set up the optimal protocol for abdominal DCE-MRI, it should be noted that TIC in the Gd-DTPA and Gd-EOB-DTPA group showed different patterns, and a slower injection rate showed a less abrupt SI change in the Gd-EOB-DTPA group than in the Gd-DTPA group. (author)

  20. A comprehensive investigation of tetragonal Gd-doped BiVO{sub 4} with enhanced photocatalytic performance under sun-light

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Yangyang; Tan, Guoqiang, E-mail: tan3114@163.com; Dong, Guohua; Ren, Huijun; Xia, Ao

    2016-02-28

    Graphical abstract: - Highlights: • Tetragonal Gd-BiVO{sub 4} with enhanced photocatalytic activity was synthesized. • Gd doping can induce the phase transition from monoclinic to tetragonal BiVO{sub 4}. • GdVO{sub 4} seeds as crystal nucleus dominate the formation of tetragonal Gd-BiVO{sub 4}. • Tetragonal Gd-BiVO{sub 4} exhibits the excellent separation of electrons and holes. • The contribution of high photocatalytic activity under sun-light is from UV-light. - Abstract: Tetragonal Gd-doped BiVO{sub 4} having enhanced photocatalytic activity have been synthesized by a facile microwave hydrothermal method. The structural analysis indicates that Gd doping can induce the phase transition from monoclinic to tetragonal BiVO{sub 4}. The reaction results in precursor solutions imply that tetragonal GdVO{sub 4} seeds as crystal nucleus are the original and determined incentives to force the formation of tetragonal Gd-BiVO{sub 4}. The influences of the surface defect, band structure, and BET surface area on the improved photocatalytic activities of tetragonal Gd-doped BiVO{sub 4} are investigated systematically. The results demonstrate that the more surface oxygen deficiencies as active sites and the excellent mobility and separation of photogenerated electrons and holes are beneficial to the enhancement of the photocatalytic performance of tetragonal Gd-BiVO{sub 4}. The RhB photodegradation experiments indicate that the contribution of high photocatalytic activities under simulated sun-light is mainly from UV-light region due to the tetragonal structure feature. The best photocatalytic performance is obtained for tetragonal 10 at% Gd-BiVO{sub 4}, of which the RhB degradation rate can reach to 96% after 120 min simulated sun-light irradiation. The stable tetragonal Gd-BiVO{sub 4} with efficient mineralization will be a promising photocatalytic material applied in water purification.

  1. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    International Nuclear Information System (INIS)

    Gehl, H.B.; Bourne, M.; Grazioli, L.; Moeller, A.; Lodemann, K.P.

    2001-01-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  2. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, H.B. [Inst. of Diagnostic Radiology, Medical Univ. of Luebeck (Germany); Bourne, M. [Dept. of Radiology, Univ. Hospital of Wales, Cardiff (United Kingdom); Grazioli, L. [Dept. of Radiology, Univ. of Brescia (Italy); Moeller, A. [MEDIDATA GmbH, Konstanz (Germany); Lodemann, K.P. [BRACCO-BYK GULDEN GmbH, Konstanz (Germany)

    2001-02-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  3. Gd-DTPA-enhanced MR imaging in facial nerve paralysis

    International Nuclear Information System (INIS)

    Tien, R.D.; Dillon, W.P.

    1989-01-01

    GD-DTPA-enhanced MR imaging was used to evaluate 11 patients with facial nerve paralysis (five acute idiopathic facial palsy (Bell palsy), three chronic recurrent facial palsy, one acute facial palsy after local radiation therapy, one chronic facial dyskinesia, and one facial neuroma). In eight of 11 patients, there was marked enhancement of the infratemporal facial nerve from the labyrinthine segment to the stylomastoid foramen. Two patients had additional contrast enhancement in the internal auditory canal segment. In one patient, enhancement persisted (but to a lesser degree) 8 weeks after symptoms had resolved. In one patient, no enhancement was seen 15 months after resolution of Bell palsy. The facial neuroma was seen as a focal nodular enhancement in the mastoid segment of the facial nerve

  4. Gd-DOTA enhancement of cerebral and spinal tumors on MR imaging

    International Nuclear Information System (INIS)

    Berry, I.; Manelfe, C.; Chastin, I.; Arrue, P.; Prere, J.

    1987-01-01

    The use of Gd-DOTA as a contrast agent in MR imaging to improve the diagnosis of cerebral and spinal tumors was assessed in 20 patients, ten with brain tumors and ten with spinal tumors. Imaging was performed with a 0.5-T Magniscan 5000 unit. T1-weighted (spin-echo and gradient-echo) and T2-weighted (spin-echo) images were acquired before and after intravenous injection of Gd-DOTA, 0.1 mmol/kg. On T1-weighted images, Gd-DOTA enhanced sites of presumed disruption of the blood-brain barrier. This made some brain tumors more conspicuous and helped target biopsies, but did not reveal any additional lesions. On the other hand, the use of Gd-DOTA significantly improved the reliability of spinal tumor imaging compared to imaging performed without contrast agent, allowing delineation of abnormalities on T1-weighted images, which frequently contain fewer artifacts than the most sensitive T2-weighted images. Images obtained with Gd-DOTA could be used by the physician to rule out residual tumor after surgery and to assess recurrences. Additional work should be done to discover whether spinal tumor exploration with MR imaging could include solely T1-weighted sequences, performed before and after contrast agent administration, without T2-weighted sequences

  5. Gd(III)-nanodiamond conjugates for MRI contrast enhancement

    Science.gov (United States)

    Manus, Lisa M.; Mastarone, Daniel J.; Waters, Emily A.; Zhang, Xue-Qing; Schultz-Sikma, Elise A.; MacRenaris, Keith W.; Ho, Dean

    2010-01-01

    A Gd(III)-nanodiamond conjugate [Gd(III)-ND] was prepared and characterized, enabling detection of nanodiamonds by MR imaging. The Gd(III)-ND particles significantly reduced the T1 of water protons with a per-Gd(III) relaxivity of 58.82 ± 1.18 mM−1s−1 at 1.5 Tesla (60 MHz). This represents a tenfold increase compared to the monomer Gd(III) complex (r1 = 5.42 ± 0.20 mM−1s−1) and is among the highest per-Gd(III) relaxivities reported. PMID:20038088

  6. Tunable paramagnetic relaxation enhancements by [Gd(DPA)3]3- for protein structure analysis

    International Nuclear Information System (INIS)

    Yagi, Hiromasa; Loscha, Karin V.; Su, Xun-Cheng; Stanton-Cook, Mitchell; Huber, Thomas; Otting, Gottfried

    2010-01-01

    Paramagnetic relaxation enhancements (PRE) present a powerful source of structural information in nuclear magnetic resonance (NMR) studies of proteins and protein-ligand complexes. In contrast to conventional PRE reagents that are covalently attached to the protein, the complex between gadolinium and three dipicolinic acid (DPA) molecules, [Gd(DPA) 3 ] 3- , can bind to proteins in a non-covalent yet site-specific manner. This offers straightforward access to PREs that can be scaled by using different ratios of [Gd(DPA) 3 ] 3- to protein, allowing quantitative distance measurements for nuclear spins within about 15 A of the Gd 3+ ion. Such data accurately define the metal position relative to the protein, greatly enhancing the interpretation of pseudocontact shifts induced by [Ln(DPA) 3 ] 3- complexes of paramagnetic lanthanide (Ln 3+ ) ions other than gadolinium. As an example we studied the quaternary structure of the homodimeric GCN4 leucine zipper.

  7. Time course of epidural scar enhancement with Gd-DTPA in an animal model

    International Nuclear Information System (INIS)

    Blaser, S.I.; Ross, J.S.; Berridge, M.; Emery, S.; Bolesta, M.J.; Modic, M.T.; Masaryk, T.J.; Bohlman, H.

    1988-01-01

    In eight beagles following laminectomies, dynamic contrast enhancement of posterior epidural scar was assessed sequentially over 4 months by means of FLASH sequence (20/10/50) following Gd-DTPA. A consistent pattern of enhancement was apparent in all dogs. Maximum enhancement occurred after 1 month (80%-130%), with peak enhancement at 7-10 minutes. There was decreased enhancement each succeeding month with a similar time to peak. Time curves were obtained for blood, muscle, and scar following injection of 40 μCi Gd-153 DTPA and correlated well with in vivo MR image intensities. Histology showed granulation tissue early following surgery, which matured to scar by 4 months. These findings are in contrast to reports of enhancement of anterior scar in humans irrespective of age. The difference may be secondary to location in that posterior scar does not receive the trauma and stress acting on anterior scar associated with a degenerative disk

  8. Non-hypervascular hypointense nodules on Gd-EOB-DTPA-enhanced MRI as a predictor of outcomes for early-stage HCC.

    Science.gov (United States)

    Toyoda, Hidenori; Kumada, Takashi; Tada, Toshifumi; Sone, Yasuhiro; Maeda, Atsuyuki; Kaneoka, Yuji

    2015-01-01

    In patients with hepatocellular carcinoma (HCC), gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) often identifies non-hypervascular hypointense hepatic nodules during the hepatobiliary phase, but their prognostic significance is unclear. We conducted a prospective observational study to investigate the impact of non-hypervascular hypointense hepatic nodules detected by Gd-EOB-DTPA-enhanced MRI on the outcome of patients with early-stage HCC. Post-treatment recurrence and survival rates were analyzed in 138 patients with non-recurrent, early-stage HCC [Barcelona Clinic Liver Cancer (BCLC) stage 0 or A] and Child-Pugh A liver function according to the presence of non-hypervascular hypointense nodules on pretreatment Gd-EOB-DTPA-enhanced MRI. Non-hypervascular hypointense hepatic nodules were detected in 51 (37.0%) patients with early-stage HCC on pretreatment Gd-EOB-DTPA-enhanced MRI. Recurrence rates were significantly higher in patients with non-hypervascular hypointense nodules (p DTPA-enhanced MRI was independently associated with an increased recurrence rate, independent of tumor progression or treatment (p = 0.0005). The survival rate was significantly lower in patients with non-hypervascular hypointense nodules on Gd-EOB-DTPA-enhanced MRI (p = 0.0108). In patients with early-stage typical HCC (BCLC 0 or A), the presence of concurrent non-hypervascular hypointense hepatic nodules in the hepatobiliary phase of pretreatment Gd-EOB-DTPA-enhanced MRI is an indicator of higher likelihood of recurrence after treatment and may be a marker for unfavorable outcome.

  9. Gd-EOB-DTPA-enhanced magnetic resonance images of hepatocellular carcinoma: correlation with histological grading and portal blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Kogita, Sachiyo; Imai, Yasuharu; Fukuda, Kazuto; Igura, Takumi; Sawai, Yoshiyuki [Ikeda Municipal Hospital, Department of Gastroenterology, Osaka (Japan); Okada, Masahiro; Murakami, Takamichi [Kinki University, School of Medicine, Department of Radiology, Osaka (Japan); Kim, Tonsok; Onishi, Hiromitsu; Hori, Masatoshi [Osaka University, Graduate School of Medicine, Department of Radiology, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Osaka (Japan); Morimoto, Osakuni [Ikeda Municipal Hospital, Department of Surgery, Osaka (Japan); Nagano, Hiroaki [Osaka University, Graduate School of Medicine, Department of Surgery, Osaka (Japan); Wakasa, Kenichi [Osaka City University, Graduate School of Medicine, Department of Diagnostic Pathology, Osaka (Japan); Hayashi, Norio [Osaka University, Graduate School of Medicine, Department of Gastroenterology and Hepatology, Osaka (Japan)

    2010-10-15

    To retrospectively investigate enhancement patterns of hepatocellular carcinoma (HCC) and dysplastic nodule (DN) in the hepatobiliary phase of gadolinium-ethoxybenzyl-diethylenetriamine (Gd-EOB-DTPA)-enhanced MRI in relation to histological grading and portal blood flow. Sixty-nine consecutive patients with 83 histologically proven HCCs and DNs were studied. To assess Gd-EOB-DTPA uptake, we calculated the EOB enhancement ratio, which is the ratio of the relative intensity of tumorous lesion to surrounding nontumorous area on hepatobiliary phase images (post-contrast EOB ratio) to that on unenhanced images (pre-contrast EOB ratio). Portal blood flow was evaluated by CT during arterial portography. Post-contrast EOB ratios significantly decreased as the degree of differentiation declined in DNs (1.00 {+-} 0.14) and well, moderately and poorly differentiated HCCs (0.79 {+-} 0.19, 0.60 {+-} 0.27, 0.49 {+-} 0.10 respectively). Gd-EOB-DTPA uptake, assessed by EOB enhancement ratios, deceased slightly in DNs and still more in HCCs, while there was no statistical difference in the decrease between different histological grades of HCC. Reductions in portal blood flow were observed less frequently than decreases in Gd-EOB-DTPA uptake in DNs and well-differentiated HCCs. Reduced Gd-EOB-DTPA uptake might be an early event of hepatocarcinogenesis, preceding portal blood flow reduction. The hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI may help estimate histological grading, although difficulties exist in differentiating HCCs from DNs. (orig.)

  10. Steroid hormone excretion is enhanced by sucrose feeding to rats

    International Nuclear Information System (INIS)

    Kruger, T.C.; Hsu, H.; Saunders, J.P.; Kim, S.S.; Given-Proctor, J.; Ahrens, R.A.

    1986-01-01

    The hypothesis tested was that feeding rats sucrose rather than invert sugar (50:50 mixture of glucose and fructose) or cornstarch would result in a more rapid excretion of intravenously injected 1,2- 3 H aldosterone or 1,2,6,7- 3 H cortisol. The three carbohydrate sources provided 45% of dietary energy when fed, respectively, to one of three groups of 10 male, Sprague Dawley rats. After 4 or 8 weeks of ad lib feeding of the three diets 5 μCI of 3 H-labeled hormones were injected intravenously and % recovery in urine and feces was measured for 4 days by liquid scintillation counting. Nearly 90% of the 3 H injected as 1,2- 3 H aldosterone was recovered over 4 days in the excreta of the sucrose fed rats. This recovery of 3 H from aldosterone was significantly greater (P 3 H from intravenously injected 1,2,6,7- 3 H cortisol followed a similar pattern. The authors anticipate that the excretion of all metabolic end products and xenobiotics excreted as glucuronides would be enhanced by sucrose feeding. Oxocarbonium ions from the glucose portion of sucrose digestion in the mammalian small intestine are thought to compete with oxocarbonium ions from the glucuronic acid portion of glucuronide hydrolysis. Such competition may slow glucuronide hydrolysis and promote glucuronide excretion, including the glucuronides derived from aldosterone and cortisol

  11. Hydrothermally synthesized PEGylated calcium phosphate nanoparticles incorporating Gd-DTPA for contrast enhanced MRI diagnosis of solid tumors.

    Science.gov (United States)

    Mi, Peng; Kokuryo, Daisuke; Cabral, Horacio; Kumagai, Michiaki; Nomoto, Takahiro; Aoki, Ichio; Terada, Yasuko; Kishimura, Akihiro; Nishiyama, Nobuhiro; Kataoka, Kazunori

    2014-01-28

    Organic-inorganic hybrid nanoparticles with calcium phosphate (CaP) core and PEGylated shell were developed to incorporate magnetic resonance imaging (MRI) contrast agent diethylenetriaminepentaacetic acid gadolinium (III) (Gd-DTPA) for noninvasive diagnosis of solid tumors. A two-step preparation method was applied to elaborate hybrid nanoparticles with a z-average hydrodynamic diameter about 80nm, neutral surface ξ-potential and high colloidal stability in physiological environments by self-assembly of poly(ethylene glycol)-b-poly(aspartic acid) block copolymer, Gd-DTPA, and CaP in aqueous solution, followed with hydrothermal treatment. Incorporation into the hybrid nanoparticles allowed Gd-DTPA to show significant enhanced retention ratio in blood circulation, leading to high accumulation in tumor positions due to enhanced permeability and retention (EPR) effect. Moreover, Gd-DTPA revealed above 6 times increase of relaxivity in the nanoparticle system compared to free form, and eventually, selective and elevated contrast enhancements in the tumor positions were observed. These results indicate the high potential of Gd-DTPA-loaded PEGylated CaP nanoparticles as a novel contrast agent for noninvasive cancer diagnosis. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Differentiation of hypertensive heart disease with hypertrophy and hepertrophic cardiomyopathy using consecutive time-course images of Gd-DTPA enhanced MRI

    International Nuclear Information System (INIS)

    Ochiai, Kouichi; Isibashi, Yutaka; Shimada, Toshio; Tsukihashi, Hironori; Sato, Hidetoshi; Kitamura, Jun; Morioka, Shigefumi; Kawamitsu, Hideaki; Sugimura, Kazuro

    1996-01-01

    We used consecutive time-course Gd-DTPA contrast magnetic resonance images to differentiate hypertrophic cardiomyopathy (HCM) from hypertensive heart disease with hypertrophy (HHD). Seventeen patients with HCM, 6 patients with HHD and 5 normal subjects (control) were studied. ECG-gated MRI with 1.5T system was performed before and after intravenous injection of Gd-DTPA (0.1mmol/Kg) using spin echo sequence. Gd-DTPA enhanced MRI was repeated every 10 to 55 minutes. We measured signal intensity (SI) of midleft ventricular myocardium and skeletal muscle, and then calculated the ratio between myocardial SI and skeletal muscle SI. Myocardium was enhanced by Gd-DTPA in all patients. However, there was difference in the decay of enhancement effect by Gd-DTPA between HCM and HHD. The decay in HCM was more slowly than in both HHD and control. There was no difference in the decay between HHD and control. The difference in the decay between HCM and HHD became significant 25 minutes after Gd-DTPA injection and lasted until 55 minutes. We conclude that the time-course of the decay of enhancement effect by Gd-DTPA is helpful to differentiate HCM from HHD and the difference of the decay might reflect structural changes of myocardium. (author)

  13. Gd-DTPA enhancement of the facial nerve in Ramsay Hunt's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Tsutomu; Yanagida, Masahiro; Yamauchi, Yasuo [Kansai Medical School, Moriguchi, Osaka (Japan); and others

    1992-10-01

    A total of 21 MR images in 16 Ramsay Hunt's syndrome were evaluated. In all images, the involved side of peripheral facial nerve were enhanced in intensity after Gd-DTPA. However, 2 cases had recovered facial palsy when MR images were taken. Nine of 19 cases with the enhancement of internal auditory canal portion had vertigo or tinnitus. Thus, it was suggested that the enhancement of internal auditory canal portion and clinical feature are closely related. (author).

  14. Gd-DTPA enhancement of the facial nerve in Ramsay Hunt's syndrome

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Yanagida, Masahiro; Yamauchi, Yasuo

    1992-01-01

    A total of 21 MR images in 16 Ramsay Hunt's syndrome were evaluated. In all images, the involved side of peripheral facial nerve were enhanced in intensity after Gd-DTPA. However, 2 cases had recovered facial palsy when MR images were taken. Nine of 19 cases with the enhancement of internal auditory canal portion had vertigo or tinnitus. Thus, it was suggested that the enhancement of internal auditory canal portion and clinical feature are closely related. (author)

  15. Toxicity evaluation of Gd2O3@SiO2 nanoparticles prepared by laser ablation in liquid as MRI contrast agents in vivo

    Directory of Open Access Journals (Sweden)

    Tian XM

    2014-08-01

    Full Text Available Xiumei Tian,1,* Fanwen Yang,1,* Chuan Yang,2 Ye Peng,1 Dihu Chen,3 Jixiang Zhu,1 Fupo He,1 Li Li,2 Xiaoming Chen11Department of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong Province, People’s Republic of China; 2State Key Laboratory of Oncology in South China, Imaging Diagnosis and Interventional Center, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong Province, People’s Republic of China; 3State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou, Guangdong Province, People’s Republic of China*These authors contributed equally to this workAbstract: Poor toxicity characterization is one obstacle to the clinical deployment of Gd2O3@SiO2 core-shell nanoparticles (Gd-NPs for use as magnetic resonance (MR imaging contrast agents. To date, there is no systematic toxicity data available for Gd-NPs prepared by laser ablation in liquid. In this article, we systematically studied the Gd-NPs’ cytotoxicity, apoptosis in vitro, immunotoxicity, blood circulation half-life, biodistribution and excretion in vivo, as well as pharmacodynamics. The results show the toxicity, and in vivo MR data show that these NPs are a good contrast agent for preclinical applications. No significant differences were found in cell viability, apoptosis, and immunotoxicity between our Gd-NPs and Gd in a DTPA (diethylenetriaminepentaacetic acid chelator. Biodistribution data reveal a greater accumulation of the Gd-NPs in the liver, spleen, lung, and tumor than in the kidney, heart, and brain. Approximately 50% of the Gd is excreted via the hepatobiliary system within 4 weeks. Furthermore, dynamic contrast-enhanced T1-weighted MR images of xenografted murine tumors were obtained after intravenous administration of the Gd-NPs. Collectively, the single step preparation of Gd-NPs by laser ablation in liquid produces particles with satisfactory cytotoxicity

  16. Utility of Gd-EOB-DTPA-Enhanced MRI in Diagnosing Small Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Soo Ryang Kim

    2009-07-01

    Full Text Available We describe an 8-mm hepatocellular carcinoma (HCC with hepatitis C virus-related cirrhosis in a 74-year-old woman. Ultrasound (US revealed an 8-mm hyperechoic nodule in segment 6 of the liver. Contrast-enhanced computed tomography (CT and US revealed no hypervascularity in the early phase and no washout in the late phase and the Kupffer phase, respectively. CT during arteriography revealed no hypervascularity and CT during arterial portography disclosed no perfusion defect. Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI revealed no hypervascularity in the early phase, but disclosed a defect in the hepatobiliary phase. Histologically, the nodule was diagnosed as well-differentiated HCC characterized by more than two-fold the cellularity of the non-tumorous area, with a high nuclear:cytoplasmic ratio, increased cytoplasmic eosinophilia, fatty change, and slight cell atypia with an irregular thin trabecular pattern. Our case demonstrates the utility of Gd-EOB-DTPA-enhanced MRI in the diagnosis of small HCC.

  17. Biliary enhanced MR imaging by Gd-DTPA

    International Nuclear Information System (INIS)

    Ohkawa, Shinichi; Fujikura, Yuji; Kanai, Toshio; Hiramatsu, Kyoichi.

    1992-01-01

    Biliary enhanced MRI (BEMRI) by Gd-DTPA via PTCD and/or PTGBD tube for obstructive jaundice was performed in 8 patients. In all cases, biliary tract was clearly visualised as high signal intensity on T1 weighted images. On same images, primary lesion such as common bile duct cancer was also visualised as well as portal system. In addition, MR angiography (MRA) by 2D-time of flight method was performed. MRA with BEMRI shows portal encasement on the same image as biliary tract obstruction. This suggests MRA with BEMRI may replace the other modality for obstructive jaundice. (author)

  18. Fate of hypointense lesions on Gd-EOB-DTPA-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Akai, Hiroyuki; Matsuda, Izuru; Kiryu, Shigeru; Tajima, Taku; Takao, Hidemasa; Watanabe, Yasushi; Imamura, Hiroshi; Kokudo, Norihiro

    2012-01-01

    Purpose: To investigate the natural outcome and clinical implication of hypointense lesions in the hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI. Materials and methods: Forty patients underwent Gd-EOB-DTPA-enhanced MRI for preoperative evaluation of HCC. Hypointense lesions in the hepatobiliary phase that were hypovascular 5 mm of more were extracted for follow-up. We performed a longitudinal study retrospectively for these lesions regardless of whether classical HCC developed or emerged in a different area from that of the lesions being followed. Results: Thirty one patients displayed 130 hypointense lesions on MRI and only nine showed no hypointense lesions. In total, 17 (13.1%) of 130 hypointense lesions on MRI developed into classical HCC. The cumulative rates for these lesions to develop into classical HCC were 3.2% at 1 year, 11.1% at 2 years and 15.9% at 3 years. The total occurrence rates of classical HCC (25.8% at 1 year, 52.6% at 2 years and 76.4% at 3 years) were higher compared to those regarding only occurrence of classical HCC from hypointense lesions on MRI (10.0% at 1 year, 35.6% at 2 years and 44.6% at 3 years), although no significant difference was observed (p = 0.073). Conclusions: Hypointense lesions that are detected in the hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI have some malignant potential, although treating these lesions aggressively in patients who already have HCC may be too severe.

  19. Hemophilic arthropathy of the knee joint: static and dynamic Gd-DTPA - enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. [Dept. of Radiology, Univ. Bonn (Germany); Bruening, R. [Dept. of Radiology, Univ. Muenchen (Germany); Kunze, V. [Dept. of Radiology, Univ. Bonn (Germany); Eickhoff, H. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Koch, W. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Reiser, M. [Dept. of Radiology, Univ. Muenchen (Germany)

    1995-12-31

    A total of 17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRI before and after an IV bolus injection of Gadolinium-DTPA (Gd-DTPA; 0.1 mmol/kg body weight). The T1-weighted spin-echo (SE) and gradient-echo (fast-field echo [FFE]) sequences were applied. The FFE sequences of eight consecutive scans carried out over a time interval of 160 s were used in order to determine the time to signal intensity (SI) curves of the synovial proliferations surrounding soft tissue, bone marrow, and joint effusion. After the administration of a contrast agent, synovial proliferations exhibited an increase on FFE and SE images of 47.7% (SD {+-} 14.3%) and 37.4% (SD {+-} 11.2%), respectively, whereas muscle and fatty tissue, tendons, bone marrow, and joint effusion revealed only a minor increase in SI. The gradient of SI (ratio SI/time) of pannus was 39.6%/min (SD {+-} 7.7%/min) and differed significantly (P < 0.001) from that of bone marrow, fatty tissue, muscle tissue, tendons, and joint effusion (P < 0.05). In contrast to synovial proliferations in rheumatoid arthritis, no differentiation between various pannus vascularities based on the degree of enhancement was possible. The Gd-DTPA-enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.)

  20. Hemophilic arthropathy of the knee joint: static and dynamic Gd-DTPA -enhanced MRI

    International Nuclear Information System (INIS)

    Naegele, M.; Bruening, R.; Kunze, V.; Eickhoff, H.; Koch, W.; Reiser, M.

    1995-01-01

    A total of 17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRI before and after an IV bolus injection of Gadolinium-DTPA (Gd-DTPA; 0.1 mmol/kg body weight). The T1-weighted spin-echo (SE) and gradient-echo (fast-field echo [FFE]) sequences were applied. The FFE sequences of eight consecutive scans carried out over a time interval of 160 s were used in order to determine the time to signal intensity (SI) curves of the synovial proliferations surrounding soft tissue, bone marrow, and joint effusion. After the administration of a contrast agent, synovial proliferations exhibited an increase on FFE and SE images of 47.7% (SD ± 14.3%) and 37.4% (SD ± 11.2%), respectively, whereas muscle and fatty tissue, tendons, bone marrow, and joint effusion revealed only a minor increase in SI. The gradient of SI (ratio SI/time) of pannus was 39.6%/min (SD ± 7.7%/min) and differed significantly (P < 0.001) from that of bone marrow, fatty tissue, muscle tissue, tendons, and joint effusion (P < 0.05). In contrast to synovial proliferations in rheumatoid arthritis, no differentiation between various pannus vascularities based on the degree of enhancement was possible. The Gd-DTPA-enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.)

  1. Gd-enhanced MR imaging of the herniated lumbar disc: patterns of enhancement

    International Nuclear Information System (INIS)

    Kwag, Hyon Joo; Choi, Hye Young; Kim, Hyae Young; Kim, Yoo Kyung; Kim, Ah Young; Chung, Eun Chul

    1995-01-01

    The purpose of this study is to describe the patterns of enhancement of the herniated lumbar disc with Gd-DTPA enhanced MR imaging. Out of 65 patients, 103 lumbar discs diagnosed to be herniated by MR image were retrospectively analyzed. The MR imaging was performed with 1.5 T MR unit, using T1-and T2-weighted sagittal and axial spin echo techniques. Contrast-enhanced T1 weighted sagittal and axial images were performed after intravenous injection of Gadopentetate-dimeglumine(Magnevist, Shering) (0.1 mmol/kg). Contrast enhancement was seen in 66 cases(64%). Thirteen cases of bulging disc were not enhanced. Twenty-eight cases of protruded disc showed intraannular enchantment in 23 cases, peripheral linear and irregular enhancement in each of one case, and nonenhancement in three cases. Fifty-seven cases of extruded disc showed irregular enhancement in 14 cases, peripheral linear enhancement in 12 cases, peripheral ring enhancement in five cases and intraannular enhancement in five cases. All five cases of sequestered disc showed peripheral ring enhancement. Protruded discs show intraannular enhancement frequently and sequestered discs usually show peripheral ring enhancement. Enhanced MR imaging may be helpful to evaluate the type of herniated lumbar disc and relationship among disc material, nerve root and thecal sac

  2. Ni3d-Gd4f correlation effects on the magnetic behaviour of GdNi

    Energy Technology Data Exchange (ETDEWEB)

    Paulose, P L [Tata Inst. of Fundamental Research, Bombay (India); Patil, Sujata [Tata Inst. of Fundamental Research, Bombay (India); Mallik, R [Tata Inst. of Fundamental Research, Bombay (India); Sampathkumaran, E V [Tata Inst. of Fundamental Research, Bombay (India); Nagarajan, V [Tata Inst. of Fundamental Research, Bombay (India)

    1996-07-01

    The results of magnetization and heat-capacity measurements on the alloys, Gd{sub 1-x}Y{sub x}Ni (x=0.0, 0.25, 0.5, 0.75 and 0.9) are reported. The data suggest that there is a Gd induced magnetic moment on Ni, which may in turn enhance Gd-Gd exchange interaction strength in GdNi. The induced moment (on Ni) apparently exhibits itinerant ferromagnetism in the magnetically ordered state of GdNi. (orig.).

  3. MR imaging with Gd-DTPA enhancement in experimental acute injury of the spinal cord

    International Nuclear Information System (INIS)

    Hackney, D.B.; Asato, R.; Joseph, P.M.; McGrath, J.T.; Grossman, R.I.; Shetty, A.

    1986-01-01

    The authors performed MR imaging with Gd-DTPA enhancement in adult male Sprague-Dawley rats, with experimentally induced acute spinal cored injuries. After epidural compression of the spinal cored the pathologic changes of acute cord contusion were allowed to develop for 30 minutes to 4 hours. MR imaging was then performed at 1.4 T. Both short spin-echo (TR = 400 msec, TE = 15-20 msec) and long spin-echo (TR = 2,000 msec, TE = 100 msec) images were obtained. After the initial imaging, Gd-DTPA (0.1 mmol/kg) and Evans blue dye were administered intravenously and imaging was repeated. Enhancement of normal central gray matter was consistently observed. However, neither pathologic enhancement on MR images nor extravasation of Evans blue dye on histologic inspection were identified

  4. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI

    International Nuclear Information System (INIS)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P.; Zeman, F.; Teufel, A.; Lang, S.

    2015-01-01

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  5. Superdeformed bands in 64147Gd83, a possible test of the existence of octupole correlations in superdeformed bands

    International Nuclear Information System (INIS)

    Zuber, K.; Balouka, D.; Beck, F.A.; Byrski, T.; Curien, D.; Duchene, G.; Gehringer, C.; Haas, B.; Merdinger, J.C.; Romain, P.; Santos, D.; Styczen, J.; Vivien, J.P.; Dudek, J.; Szymanski, Z.; Werner, T.

    1990-01-01

    Two discrete superdeformed bands (SD) have been identified in the nucleus 147 Gd. The transitions energies of the SD yrast band lie halfway between the γ-ray energies of the yrast SD band in 146 Gd while the transition energies of the excited band lie half way between the transition energies of the yrast SD band in 148 Gd. These two bands are shown to exhibit the presence of the pseudo SU(3) symmetry and also indicate the possible existence of octupole correlations at large elongations and high spins. (orig.)

  6. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  7. Gd-EOB-DTPA-enhanced magnetic resonance imaging for bile duct intraductal papillary mucinous neoplasms

    OpenAIRE

    Ying, Shi-Hong; Teng, Xiao-Dong; Wang, Zhao-Ming; Wang, Qi-Dong; Zhao, Yi-Lei; Chen, Feng; Xiao, Wen-Bo

    2015-01-01

    AIM: To investigate gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) of intraductal papillary mucinous neoplasms of the bile duct (IPMN-B).

  8. Gd-DTPA enhanced MR imaging in Bell's palsy

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Kawamura, Yuji; Yanagihara, Naoaki; Sadamoto, Masanori; Sadamoto, Kazuhiko.

    1991-01-01

    Magnetic resonance imaging (MRI) was carried out in 27 patients with Bell's palsy. T1-weighted spin-echo images (TR500/TE25-34) were taken before and after the intravenous administration of Gd-DTPA (0.1 mmol/kg) with 0.5T superconductive MRI. There was significant enhancement at the geniculate ganglion and the horizontal segment of the involved facial nerve in 22 patients (81.5%) and at the vertical segment in 20 (74.1%). Enhancement at the meatal fundus was seen in only 4 patients (14.9%) and at the labyrinthine segment in 8 (29.6%). These results corroborate other evidence that the geniculate ganglion is involved most frequently in Bell's palsy. In addition, the enhancement of the proximal portion, i.e. the meatal fundus and the labyrinthine segment of the nerve, although not common, noted in this study may be important in the diagnosis and treatment of Bell's palsy. (author)

  9. Enhanced flux pinning by BaZrO3 and (Gd,y)2O3 nano-structures in metal organic chemical vapor deposited GdYBCO high temperature superconductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y [SuperPower Incorporated, Schenectady, New York; Selvamanickam, V. [SuperPower Incorporated, Schenectady, New York; Paranthaman, Mariappan Parans [ORNL; Cantoni, Claudia [ORNL; Aytug, Tolga [ORNL; Goyal, Amit [ORNL; Lee, Dominic F [ORNL; Specht, Eliot D [ORNL; Zuev, Yuri L [ORNL; Zhang, Yifei [ORNL

    2009-01-01

    We have formed BaZrO3 nano-columns and (Gd,Y)2O3 nano-precipitates in reel-to-reel MOCVD processed (Gd,Y)Ba2Cu3O7-x coated conductors and increased the critical currents (Ic) of the conductors in applied magnetic fields to remarkable levels. A (Gd,Y)Ba2Cu3O7-x tape of 1m length with 6.5% Zr-additions and 30% composition rich in both Gd and Y showed Ic values of 813 A/cm-width at (self-field, 77K) and above 186 A/cm-width at (1T, 77K). The strongly enhanced flux pinning over a wide range of magnetic field orientations can be attributed to the bidirectionally aligned defect structures of BaZrO3 and (Gd,Y)2O3 created by optimized MOCVD conditions.

  10. Gadolinium-enhanced turbo FLASH MR imaging of renal perfusion and excretion

    International Nuclear Information System (INIS)

    Watanabe, A.; Teresi, L.M.; Herbst, M.; O'Sullivan, R.M.; Lee, R.; Smith, C.; Renner, J.; Rappaport, A.; Bradley, W.G. Jr.

    1990-01-01

    This paper describes a novel approach to MR imaging of renal perfusion and excretion using gadolinium-enhanced, T1-weighted TURBP, fast low-angle shot (FLASH) imaging. Five normal volunteers and four patients were studied on a 1.5-T imaging system. Time-intensity curves of the appearance of gadolinium in each kidney and the bladder were then generated. In normal volunteers, marked first-pass enhancement of renal cortex followed by renal pyramids and collecting systems could be demonstrated on the first-pass gadolinium images. Delayed images showed hyperintense gadolinium within the bladder

  11. Added value of Gd-EOB-DTPA-enhanced Hepatobiliary phase MR imaging in evaluation of focal solid hepatic lesions

    International Nuclear Information System (INIS)

    Haimerl, Michael; Wächtler, Max; Platzek, Ivan; Müller-Wille, Rene; Niessen, Christoph; Hoffstetter, Patrick; Schreyer, Andreas Georg; Stroszczynski, Christian; Wiggermann, Philipp

    2013-01-01

    Correct characterization of focal solid hepatic lesions has always been a challenge and is of great diagnostic and therapeutic relevance. The purpose of this study was to determine the added value of hepatobiliary phase images in Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) for differentiating focal solid hepatic lesions. In this retrospective trial 84 consecutive patients underwent Gd-EOB-DTPA-enhanced MR examinations. MRI was conducted for 64 patients with malignant focal hepatic lesions (34 hepatocellular carcinoma (HCC), 30 metastases) and for 20 patients with benign hepatic lesions (14 focal nodular hyperplasia (FNH), 3 adenoma, 3 hemangioma). Five radiologists independently reviewed three sets of MR images by means of a 5-point confidence scale from score 1 (definitely benign) to score 5 (definitely malignant): set 1: unenhanced images; set 2: unenhanced and Gd-EOB-DTPA-enhanced dynamic images; set 3: hepatobiliary phase images in addition to set 2. Accuracy was assessed by the alternative free-response receiver operating characteristic curve (A z ) and the index of diagnostic performance was calculated. Diagnostic accuracy was significantly improved by the addition of Gd-EOB-DTPA-enhanced dynamic images: A z in set 1 was 0.708 and 0.833 in set 2 (P = 0.0002). The addition of hepatobiliary phase images increased the A z value to 0.941 in set 3 (set 3 vs set 2, P < 0.0001; set 3 vs set 1, P < 0.0001). The index of diagnostic performance was lowest in set 1 (45%), improved in set 2 (71%), and highest in set 3 (94%). Hepatobiliary phase images obtained after Gd-EOB-DTPA-enhanced dynamic MRI improve the differentiation of focal solid hepatic lesions

  12. Biliary excretion of ouabain in isolated perfused rat liver after treatment with microsomal enzyme inducers

    International Nuclear Information System (INIS)

    Nevasaari, K.; Alakare, B.; Kaerki, N.T.

    1976-01-01

    The effect of pretreatment with spironolactone, phenobarbital and 3,4-benzpyrene on biliary excretion of ouabain was studied in isolated perfused rat liver system after a single dose of 3 H-ouabain. Spironolactone pretreatment (100 mg/kg intraperitoneally for 4 days) changed the time course of the excretion, thus accelerating the transport of ouabain into the bile. Phenobarbital pretreatment (75 mg/kg intraperitoneally for 4 days) enhanced bile flow and increased biliary excretion of ouabain only after 15 min. At longer time periods the increase in bile flow diluted the bile level of ouabain there being no difference in the amounts excreted into the bile between the treated and untreated groups. 3,4-benzpyrene pretreatment (20 mg/kg intraperitoneally for 4 days) was without efffect on biliary excretion of ouabain. The results suggest that spironolactone differs from phenobarbital in its enhancing effect on biliary excretion of ouabain, possibly through a specific effect on an unknown hepatic transport mechanism. (author)

  13. Absorption and excretion tests

    International Nuclear Information System (INIS)

    Berberich, R.

    1988-01-01

    The absorption and excretion of radiopharmaceuticals is still of interest in diagnostic investigations of nuclear medicine. In this paper the most common methods of measuring absorption and excretion are described. The performance of the different tests and their standard values are discussed. More over the basic possibilities of measuring absorption and excretion including the needed measurement equipments are presented. (orig.) [de

  14. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  15. Gd-DTPA enhancement of the facial nerve in Ramsay Hunt's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Tsutomu; Yanagida, Masahiro; Yamauchi, Yasuo (Kansai Medical School, Moriguchi, Osaka (Japan)) (and others)

    1992-10-01

    A total of 21 MR images in 16 Ramsay Hunt's syndrome were evaluated. In all images, the involved side of peripheral facial nerve were enhanced in intensity after Gd-DTPA. However, 2 cases had recovered facial palsy when MR images were taken. Nine of 19 cases with the enhancement of internal auditory canal portion had vertigo or tinnitus. Thus, it was suggested that the enhancement of internal auditory canal portion and clinical feature are closely related. (author).

  16. Functional evaluation of transplanted kidneys by Gd-DTPA enhanced turbo FLASH MR imaging

    International Nuclear Information System (INIS)

    Nakashima, Rumi; Yamashita, Yasuyuki; Tomiguchi, Seiji; Tsuji, Akinori; Takahashi, Mutsumasa

    1996-01-01

    We evaluated the usefulness of dynamic turbo FLASH MR imaging in the differential diagnosis of complications after renal transplantation in 17 patients (10 from living relatives and 7 from cadavers). Coronal turbo FLASH dynamic images were obtained every 5 sec for 5 min after an intravenous bolus injection of Gd-DTPA. Corticomedullary differentiation (CMD) on spin echo coronal T 1 -weighted images and MR renogram patterns of the renal cortex and medulla were obtained for quantitative analysis of the Gd-DTPA-enhanced dynamic turbo-FLASH images. The signal intensity ratio of the medulla to cortex after Gd-DTPA enhancement was compared among four groups: normal (n=9), acute tubular necrosis (ATN) or cyclosporine A (CyA) tubulopathy (n=6), acute rejection (AR) in the living related donor kidney (n=4), and AR in the cadaveric kidney (n=5). Although loss of CMD was seen in severe renal dysfunction in the transplanted kidneys, there was considerable overlap among the four groups. On dynamic study, there was significant differences in the signal intensity ratio of the medulla to cortex between normally functioning kidneys or ATN/CyA tubulopathy and AR (p<0.01). In patients with severe renal dysfunction, the arterial cortical peak was indistinct. In conclusion, MR renograms obtained from dynamic turbo FLASH MR imaging played a significant role in evaluating dysfunction of the renal transplant. (author)

  17. Enhanced room temperature multiferroicity in Gd doped BFO

    CSIR Research Space (South Africa)

    Pradhan, SK

    2009-01-01

    Full Text Available deficient Gd doped multiferroic BFO system. At particular doping level of Gd, this bulk ceramics showed spectacular M~H behavior at room temperature which is likely to open a new avenue for the potential applications in information storing technology as well...

  18. Volume-assisted estimation of liver function based on Gd-EOB-DTPA-enhanced MR relaxometry

    Energy Technology Data Exchange (ETDEWEB)

    Haimerl, Michael; Schlabeck, Mona; Verloh, Niklas; Fellner, Claudia; Stroszczynski, Christian; Wiggermann, Philipp [University Hospital Regensburg, Department of Radiology, Regensburg (Germany); Zeman, Florian [University Hospital Regensburg, Center for Clinical Trials, Regensburg (Germany); Nickel, Dominik [MR Applications Development, Siemens AG, Healthcare Sector, Erlangen (Germany); Barreiros, Ana Paula [University Hospital Regensburg, Department of Internal Medicine I, Regensburg (Germany); Loss, Martin [University Hospital Regensburg, Department of Surgery, Regensburg (Germany)

    2016-04-15

    To determine whether liver function as determined by indocyanine green (ICG) clearance can be estimated quantitatively from hepatic magnetic resonance (MR) relaxometry with gadoxetic acid (Gd-EOB-DTPA). One hundred and seven patients underwent an ICG clearance test and Gd-EOB-DTPA-enhanced MRI, including MR relaxometry at 3 Tesla. A transverse 3D VIBE sequence with an inline T1 calculation was acquired prior to and 20 minutes post-Gd-EOB-DTPA administration. The reduction rate of T1 relaxation time (rrT1) between pre- and post-contrast images and the liver volume-assisted index of T1 reduction rate (LVrrT1) were evaluated. The plasma disappearance rate of ICG (ICG-PDR) was correlated with the liver volume (LV), rrT1 and LVrrT1, providing an MRI-based estimated ICG-PDR value (ICG-PDR{sub est}). Simple linear regression model showed a significant correlation of ICG-PDR with LV (r = 0.32; p = 0.001), T1{sub post} (r = 0.65; p < 0.001) and rrT1 (r = 0.86; p < 0.001). Assessment of LV and consecutive evaluation of multiple linear regression model revealed a stronger correlation of ICG-PDR with LVrrT1 (r = 0.92; p < 0.001), allowing for the calculation of ICG-PDR{sub est}. Liver function as determined using ICG-PDR can be estimated quantitatively from Gd-EOB-DTPA-enhanced MR relaxometry. Volume-assisted MR relaxometry has a stronger correlation with liver function than does MR relaxometry. (orig.)

  19. Distribution patterns of Gd-DTPA-enhanced magnetic resonance imaging after intravenous tissue plasminogen activator therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Fukuzawa, Shigeru; Watanabe, Hiroyuki; Shimada, Kazuhiro; Katagiri, Nakoto; Ozawa, Shun

    1994-01-01

    In patients who received thrombolytic therapy for acute myocardial infarction (AMI), we observed 3 distinct patterns in gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA)-enhanced magnetic resonance (MR) imaging. To clarify the significance of these distribution patterns of Gd-DTPA, 20 consecutive patients underwent Gd-DTPA-enhanced MR imaging 7-10 days after AMI. All of the patients received intravenous recombinant tissue plasminogen activator (IVTPA) within 6 h of onset. Echocardiograms were obtained prior to and serially over 10 days, and interpreted for regional wall motion. Coronary angiograms were obtained the day before discharge. None of the 6 patients with a closed infarct-related artery, and 9 of the 14 patients with an open artery, demonstrated subendocardial enhancement (p<0.05). All of these latter 9 patients demonstrated a significant improvement in wall motion between days 1 and 10 after AMI. In contrast, only 1 of the 7 patients with transmural enhancement and none of the 4 patients with non-homogeneous enhancement demonstrated improvement of wall motion on day 10 (p<0.05). We concluded that subendocardial enhancement was a fair prognostic sign for restoration of regional cardiac function in patients who received IVTPA during AMI. (author)

  20. Serial assessment of the area at risk in myocardial infarction with Gd-DTPA-enhanced MR imaging in humans

    International Nuclear Information System (INIS)

    de Roos, A.; Doornbos, J.; Matheijssen, N.; van Dijkman, P.; van der Wall, E.; van Voorthuisen, A.E.

    1989-01-01

    Experimental studies have shown that the region of increased myocardial signal intensity with Gd-DTPA correlates with the area at risk but overestimates the infarct size. The authors have assessed the evolution of the area at risk in acute myocardial infarction in seven patients, using Gd-DTPA enhanced MR imaging at 1 and 2 weeks after the acute event. Multisection MR imaging of the total left ventricle was performed at 0.5 T after injection of 0.2 mmol/kg of Gd-DTPA. The area with a signal intensity greater than that of normal myocardium (± 2SDs) was designated as the area at risk in each section. The summation of these areas was measured by two observers at 1 and 2 weeks after infarction; intra- and interobserver variability was 3%. The area at risk ranged from 3% to 18%; at 2 weeks the size of the area at risk showed only slight changes (P = not significant). The authors discuss how Gd- DTPA enhances the area at risk and may be useful in assessing the evolution of the size of this area

  1. MRI enhancement of the facial nerve with Gd-DTPA, 2

    International Nuclear Information System (INIS)

    Yanagida, Masahiro

    1993-01-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author)

  2. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI; Multivariable Analyse klinischer Einflussfaktoren auf die Signalintensitaet bei Gd-EOB-DTPA 3T-MRT der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P. [University Hospital Regensburg (Germany). Dept. of Radiology; Zeman, F. [University Hospital Regensburg (Germany). Center for Clinical Trials; Teufel, A. [University Hospital Regensburg (Germany). Dept. of Gastroenterology; Lang, S. [University Hospital Regensburg (Germany). Dept. of Surgery

    2015-01-15

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  3. A study utility of gadolinium enhanced magnetic resonance imaging (Gd-MRI) in the preoperative diagnosis of lymph node metastasis of esophageal carcinoma

    International Nuclear Information System (INIS)

    Makino, Harufumi

    1997-01-01

    We evaluated the utility of gadolinium enhanced magnetic resonance imaging (Gd-MRI) in the diagnosis of lymph node metastasis of esophageal carcinoma. Gd-MRI was performed in 42 patients with esophageal carcinoma. The intensities of 50 lymph nodes in MR imaging were measured. No differences were observed in intensity between metastatic and non-metastatic nodes. However, intensity values did overlap. Thus, the author devised a new method allowing comparison of metastatic and non-metastatic nodes on Gd-MRI utilizing an enhancement ratio (ER). ER higher than 45% reflected metastatic nodes. (author)

  4. Plain and Gd-DTPA-enhanced MR imaging in sjoegren syndrome of the parotid gland

    International Nuclear Information System (INIS)

    Vogl, T.J.; Dresel, S.; Spath, M.; Schedel, H.J.; Lissner, J.

    1990-01-01

    This paper reports that up to now in the diagnostic management of myoepithelial sialoadenitis (Sjogren syndrome), sialography was considered an essential imaging method. Now, results of MR imaging in this disease may offer new possibilities in diagnostic imaging. Twenty-eight patients with immunohistologically and serologically confirmed Sjogren syndrome were examined in transverse and coronal orientations. Images were obtained before and after Gd-DTPA administration with T1-weighted sequences (TR/TE = 500/25 msec) and before Gd-DTPA with T2-weighted sequences (TR/TE = 1600/90 msec)

  5. Highly biocompatible TiO2:Gd3+ nano-contrast agent with enhanced longitudinal relaxivity for targeted cancer imaging

    Science.gov (United States)

    Chandran, Parwathy; Sasidharan, Abhilash; Ashokan, Anusha; Menon, Deepthy; Nair, Shantikumar; Koyakutty, Manzoor

    2011-10-01

    We report the development of a novel magnetic nano-contrast agent (nano-CA) based on Gd3+ doped amorphous TiO2 of size ~25 nm, exhibiting enhanced longitudinal relaxivity (r1) and magnetic resonance (MR) contrasting together with excellent biocompatibility. Quantitative T1 mapping of phantom samples using a 1.5 T clinical MR imaging system revealed that the amorphous phase of doped titania has the highest r1 relaxivity which is ~2.5 fold higher than the commercially used CA Magnevist™. The crystalline (anatase) samples formed by air annealing at 250 °C and 500 °C showed significant reduction in r1 values and MR contrast, which is attributed to the loss of proton-exchange contribution from the adsorbed water and atomic re-arrangement of Gd3+ ions in the crystalline host lattice. Nanotoxicity studies including cell viability, plasma membrane integrity, reactive oxygen stress and expression of pro-inflammatory cytokines, performed on human primary endothelial cells (HUVEC), human blood derived peripheral blood mononuclear cells (PBMC) and nasopharyngeal epidermoid carcinoma (KB) cell line showed excellent biocompatibility up to relatively higher doses of 200 μg ml-1. The potential of this nano-CA to cause hemolysis, platelet aggregation and plasma coagulation were studied using human peripheral blood samples and found no adverse effects, illustrating the possibility of the safe intravenous administration of these agents for human applications. Furthermore, the ability of these agents to specifically detect cancer cells by targeting molecular receptors on the cell membrane was demonstrated on folate receptor (FR) positive oral carcinoma (KB) cells, where the folic acid conjugated nano-CA showed receptor specific accumulation on cell membrane while leaving the normal fibroblast cells (L929) unstained. This study reveals that the Gd3+ doped amorphous TiO2 nanoparticles having enhanced magnetic resonance contrast and high biocompatibility is a promising candidate for

  6. The fate of Gd and chelate following intravenous injection of gadodiamide in rats

    International Nuclear Information System (INIS)

    Moerk Kindberg, Grete; Uran, Steinar; Friisk, Grete; Martinsen, Ivar; Skotland, Tore

    2010-01-01

    The biodistribution of gadolinium (Gd) and chelate was studied in rats injected intravenously with a commercially available gadodiamide magnetic resonance contrast agent spiked with trace amounts of 14 C-labelled GdDTPA-BMA. Biodistribution of the 14 C-labelled ligand in whole animals was visualised using quantitative whole-body autoradiography, and quantified in individual tissue samples by analysing for radioactivity using beta-counting. Biodistribution of Gd was measured by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and inductively coupled plasma sector field mass spectrometry (ICP-SF-MS). The injected dose was rapidly excreted, with only 1.0% remaining in the body at 24 h. The radioactivity thereafter was mainly associated with kidney cortex, liver, lung, muscle and skin, with a similar rate of clearance for both ligand and Gd from these tissues. The ratio between 14 C-labelled substance and Gd was not significantly different from that of the injected substance in most tissue samples up to 24 h after injection; the ratio then slowly decreased. The data clearly show that measurements of Gd concentration alone in tissue samples from animals injected with Gd-based contrast agents (GBCAs) cannot be used as a measure of Gd released from the ligand. To our knowledge, such measurements comparing Gd and ligand concentrations and distribution in tissue samples have not been published previously for any of the commercial GBCAs. (orig.)

  7. Carbon monoxide may enhance bile secretion by increasing glutathione excretion and Mrp2 expression in rats

    Directory of Open Access Journals (Sweden)

    Chiung-Yu Chen

    2013-05-01

    Conclusion: The present study demonstrated that CO enhanced biliary output in conjunction with NO by increasing the biliary excretion of glutathione. The increment in biliary glutathione was associated with an increased expression of hepatic Mrp2.

  8. Tissue gadolinium deposition in hepatorenally impaired rats exposed to Gd-EOB-DTPA: evaluation with inductively coupled plasma mass spectrometry (ICP-MS).

    Science.gov (United States)

    Sato, Tomohiro; Tamada, Tsutomu; Watanabe, Shigeru; Nishimura, Hirotake; Kanki, Akihiko; Noda, Yasufumi; Higaki, Atsushi; Yamamoto, Akira; Ito, Katsuyoshi

    2015-06-01

    This study was undertaken to quantify tissue gadolinium (Gd) deposition in hepatorenally impaired rats exposed to gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) by means of inductively coupled plasma mass spectrometry (ICP-MS) and to compare differences in Gd distribution among major organs as possible triggers for nephrogenic systemic fibrosis. Five hepatorenally impaired rats (5/6-nephrectomized, with carbon-tetrachloride-induced liver fibrosis) were injected with Gd-EOB-DTPA. Histological assessment was conducted and Gd content of the skin, liver, kidneys, lungs, heart, spleen, diaphragm, and femoral muscle was measured by inductively coupled plasma mass spectrometry (ICP-MS) at 7 days after last injection. In addition, five renally impaired rats were injected with Gd-EOB-DTPA and the degree of tissue Gd deposition was compared with that in the hepatorenally impaired rats. ICP-MS analysis revealed significantly higher Gd deposition in the kidneys, spleen, and liver (p = 0.009-0.047) in the hepatorenally impaired group (42.6 ± 20.1, 17.2 ± 6.1, 8.4 ± 3.2 μg/g, respectively) than in the renally impaired group (17.2 ± 7.7, 5.4 ± 2.1, 2.8 ± 0.7 μg/g, respectively); no significant difference was found for other organs. In the hepatorenally impaired group, Gd was predominantly deposited in the kidneys, followed by the spleen, liver, lungs, skin, heart, diaphragm, and femoral muscle. Histopathological investigation revealed hepatic fibrosis in the hepatorenally impaired group. Compared with renally impaired rats, tissue Gd deposition in hepatorenally impaired rats exposed to Gd-EOB-DTPA was significantly increased in the kidneys, spleen, and liver, probably due to the impairment of the dual excretion pathways of the urinary and biliary systems.

  9. Gd-DTPA enhanced MR imaging in Bell's palsy

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Yasushi; Kawamura, Yuji (Takanoko Hospital, Matsuyama, Ehime (Japan)); Yanagihara, Naoaki; Sadamoto, Masanori; Sadamoto, Kazuhiko

    1991-09-01

    Magnetic resonance imaging (MRI) was carried out in 27 patients with Bell's palsy. T1-weighted spin-echo images (TR500/TE25-34) were taken before and after the intravenous administration of Gd-DTPA (0.1 mmol/kg) with 0.5T superconductive MRI. There was significant enhancement at the geniculate ganglion and the horizontal segment of the involved facial nerve in 22 patients (81.5%) and at the vertical segment in 20 (74.1%). Enhancement at the meatal fundus was seen in only 4 patients (14.9%) and at the labyrinthine segment in 8 (29.6%). These results corroborate other evidence that the geniculate ganglion is involved most frequently in Bell's palsy. In addition, the enhancement of the proximal portion, i.e. the meatal fundus and the labyrinthine segment of the nerve, although not common, noted in this study may be important in the diagnosis and treatment of Bell's palsy. (author).

  10. Superdeformed bands in sub 64 sup 147 Gd sub 83 , a possible test of the existence of octupole correlations in superdeformed bands

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, K.; Balouka, D.; Beck, F.A.; Byrski, T.; Curien, D.; Duchene, G.; Gehringer, C.; Haas, B.; Merdinger, J.C.; Romain, P.; Santos, D.; Styczen, J.; Vivien, J.P.; Dudek, J.; Szymanski, Z.; Werner, T. (Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires)

    1990-12-24

    Two discrete superdeformed bands (SD) have been identified in the nucleus {sup 147}Gd. The transitions energies of the SD yrast band lie halfway between the {gamma}-ray energies of the yrast SD band in {sup 146}Gd while the transition energies of the excited band lie half way between the transition energies of the yrast SD band in {sup 148}Gd. These two bands are shown to exhibit the presence of the pseudo SU(3) symmetry and also indicate the possible existence of octupole correlations at large elongations and high spins. (orig.).

  11. Gd-functionalised Au nanoparticles as targeted contrast agents in MRI: relaxivity enhancement by polyelectrolyte coating.

    Science.gov (United States)

    Warsi, Muhammad Farooq; Adams, Ralph W; Duckett, Simon B; Chechik, Victor

    2010-01-21

    Monolayer-protected, Gd(3+)-functionalised gold nanoparticles with enhanced spin-lattice relaxivity (r(1)) were prepared; adsorption of polyelectrolytes on these materials further increased r(1) and ligand exchange with a biotin-derivatised disulfide led to a prototype avidin-targeted contrast agent.

  12. Luminescent GdVO_4:Sm"3"+ quantum dots enhance power conversion efficiency of bulk heterojunction polymer solar cells by Förster resonance energy transfer

    International Nuclear Information System (INIS)

    Bishnoi, Swati; Gupta, Vinay; Sharma, Gauri D.; Chand, Suresh; Sharma, Chhavi; Kumar, Mahesh; Haranath, D.; Naqvi, Sheerin

    2016-01-01

    In this work, we report enhanced power conversion efficiency (PCE) of bulk heterojunction polymer solar cells by Förster resonance energy transfer (FRET) from samarium-doped luminescent gadolinium orthovanadate (GdVO_4:Sm"3"+) quantum dots (QDs) to polythieno[3,4-b]-thiophene-co-benzodithiophene (PTB7) polymer. The photoluminescence emission spectrum of GdVO_4:Sm"3"+ QDs overlaps with the absorption spectrum of PTB7, leading to FRET from GdVO_4:Sm"3"+ to PTB7, and significant enhancements in the charge-carrier density of excited and polaronic states of PTB7 are observed. This was confirmed by means of femtosecond transient absorption spectroscopy. The FRET from GdVO_4:Sm"3"+ QDs to PTB7 led to a remarkable increase in the power conversion efficiency (PCE) of PTB7:GdVO_4:Sm"3"+:PC_7_1BM ([6,6]-phenyl-C_7_1-butyric acid methyl ester) polymer solar cells. The PCE in optimized ternary blend PTB7:GdVO_4:Sm"3"+:PC_7_1BM (1:0.1:1.5) is increased to 8.8% from 7.2% in PTB7:PC_7_1BM. This work demonstrates the potential of rare-earth based luminescent QDs in enhancing the PCE of polymer solar cells.

  13. Postdiscectomy lumbar MR with GD-DTPA in differentation between scar tissue and recurrent prolapse

    International Nuclear Information System (INIS)

    Majewski, A.; Pedrosa, P.; Schuth, M.; Higer, H.P.

    1989-01-01

    The non-invasive diagnostic possibilities of MR have resulted in better diagnosis of degenerative spinal diseases. Twenty-one patients with failed back surgery syndrome (postdiscectomy syndrome) were studied to evaluate the possibility of 1-Tesla magnetic resonance (MR) imaging with gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) in differentiating post operative scar tissue from recurrent disc herniation. The enhanced MR studies correctly depicted the character of abnormal epidural tissue in all patients. We conclude that MR with Gd-DTPA might be the method of choice to differentiate reliably postoperative epidural fibrosis from recurrent disc prolapse. (orig.) [de

  14. Structural, magnetic, and electrical properties of Gd-doped BiFeO3 nanoparticles with reduced particle size

    International Nuclear Information System (INIS)

    Lotey, Gurmeet Singh; Verma, N. K.

    2012-01-01

    Pure and Gd-doped BiFeO 3 nanoparticles have been synthesized by sol–gel method. The significant effects of size and Gd-doping on structural, electrical, and magnetic properties have been investigated. X-ray diffraction study reveals that the pure BiFeO 3 nanoparticles possess rhombohedral structure, but with 10% Gd-doping complete structural transformation from rhombohedral to orthorhombic has been observed. The particle size of pure and Gd-doped BiFeO 3 nanoparticles, calculated using Transmission electron microscopy, has been found to be in the range 25–15 nm. Pure and Gd-doped BiFeO 3 nanoparticles show ferromagnetic character, and the magnetization increases with decrease in particle size and increase in doping concentration. Scanning electron microscopy study reveals that grain size decreases with increase in Gd concentration. Well-saturated polarization versus electric field loop is observed for the doped samples. Leakage current density decreases by four orders by doping Gd in BiFeO 3 . The incorporation of Gd in BiFeO 3 enhances spin as well as electric polarization at room temperature. The possible origin of enhancement in these properties has been explained on the basis of dopant and its concentration, phase purity, small particle, and grain size.

  15. Magnetic and transport properties of sputtered Gd-Y multilayers

    International Nuclear Information System (INIS)

    Freitas, P.P.; From, M.; Melo, L.V.

    1991-01-01

    Gd-Y-Gd multilayers were prepared that show a magnetoresistance enhancement for an Y layer separation of 30 A. This magnetoresistance enhancement is an interface effect and occurs in samples where some degree of antiferromagnetic coupling is present

  16. Localization and screening in GdNi alloy films

    Energy Technology Data Exchange (ETDEWEB)

    Wu, N.; Dowben, P.A. [Department of Physics and Astronomy, Nebraska Center for Materials and Nanoscience, University of Nebraska-Lincoln, Theodore Jorgenson Hall, 855 North 16th Street, Lincoln, Nebraska 68588-0299 (United States); LaGraffe, D. [Office of Proliferation Detection NA-22, National Nuclear Security Administration, US Department of Energy, 1000 Independence Avenue SW, Washington, DC 20585 (United States); Yakovkin, I.N. [National Academy of Science of Ukraine, Institute of Physics, Prospect Nauki 46, 03028 Kiev (Ukraine)

    2011-05-15

    Gd/Ni compounds with different Gd concentration have been investigated with constant initial state spectroscopy (CIS) of photoemission utilizing the light of synchrotron radiation. The photoemission cross-sections of Gd 5d and 4f states show a strong resonance in CIS spectra at the Gd 5p absorption edge. The screenings of Gd ions by Ni 3d conduction electrons results in a dramatic suppression of the 5p{sup 6}4f{sup 7}5d{sup 1}6s{sup 2} to 5p{sup 5}4f{sup 7}5d{sup 2}6s{sup 2} resonant enhancement of photoemission valence band intensities. This decrease in the super-Coster-Kronig photoemission resonant enhancement of the valence band can be related to the hybridized Gd 5d and Ni 3d bands near the Fermi level, consistent with performed first-principles calculations of local densities of states. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Assessment of fixed charge density in regenerated cartilage by Gd-DTPA-enhanced MRI

    International Nuclear Information System (INIS)

    Miyata, Shogo; Homma, Kazuhiro; Numano, Tomokazu; Furukawa, Katsuko; Tateishi, Tetsuya; Ushida, Takashi

    2006-01-01

    Applying regenerated cartilage in a clinical setting requires noninvasive evaluation to detect the maturity of cartilage tissue. Magnetic resonance (MR) imaging of articular cartilage is well accepted and has been applied clinically in recent years. We attempt to establish a noninvasive method to evaluate the maturity of regenerated cartilage tissue using gadolinium-enhanced MR imaging. To reconstruct cartilaginous tissue, we embedded articular chondrocytes harvested from bovine humeral head in agarose gel and cultured the cells in vitro up to 4 weeks. The fixed charge density (FCD) of the cartilage was determined using MRI gadolinium exclusion method. The sulfated glycosaminoglycan (sGAG) content was determined by dimethylmethylene blue dye-binding assay. The sGAG content and FCD of the regenerated cartilage increased with duration of culture. In the T 1 Gd maps, the [Gd-DTPA 2- ] in the specimen decreased, and the boundary between the sample disk and the bath solution of phosphate buffered saline (PBS) became clearer as time in culture increased. In the linear regression analysis, FCD and sGAG content correlated significantly. Gadolinium-enhanced MR imaging measurements can be useful predictors of the degree of cartilaginous tissue formation. (author)

  18. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  19. Effect of Al2Gd on microstructure and properties of laser clad Mg–Al–Gd coatings

    International Nuclear Information System (INIS)

    Chen, Hong; Zhang, Ke; Yao, Chengwu; Dong, Jie; Li, Zhuguo; Emmelmann, Claus

    2015-01-01

    Highlights: • Mg–Al–Gd coatings with different Gd contents were fabricated by fiber laser cladding. • Chemical compositions and crystal structures of the second phases were characterized. • Dispersion of Al 2 Gd led to further grain refining and elevated mechanical properties. • Al 2 Gd improved high-temperature performances by preventing tiny liquation. - Abstract: In order to investigate the effects of Gd addition on the microstructures and properties of magnesium coatings, the Mg–7.5Al–xGd (x = 0, 2.5, 5.0 and 7.5 wt.%) coatings on cast magnesium alloy were fabricated by laser cladding with wire feeding. The results indicated that the gadolinium (Gd) addition led to the formation of a cubic Al 2 Gd phase as well as suppressed the precipitation of eutectic Mg 17 Al 12 phase. The laser clad coating containing nominally 7.5 wt.% Gd presented the highest microhardness, ultimate tensile strength and yield strength at both room temperature and high temperatures. The enhancement of heat resistant capacities was chiefly attributed to the existence of thermally stable Al 2 Gd particles, which prevented tiny liquation of eutectic phases along the grain boundaries and made great contributions on maintaining high yield ratio during high-temperature deformation

  20. Enhanced population of side band of {sup 155}Gd in heavy-ion Coulomb excitation

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Masumi; Hayakawa, Takehito; Hatsukawa, Yuichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; and others

    1998-03-01

    In the Coulomb excitation of {sup 155}Gd with heavy projectiles, {sup 32}S, {sup 58}Ni and {sup 90}Zr, unexpectedly large enhancement of a positive-parity side band has been observed. This enhancement could not be reproduced by a Coulomb-excitation calculation taking into account the recommended upper limits of E1 or E3 transitions, which are compiled in the whole mass region, and is proportional to the electric field accomplished in the Coulomb-scattering process. (author)

  1. Experimental MR imaging with Gd-DOTA: Preliminary results

    International Nuclear Information System (INIS)

    Schouman-Claeys, E.; Kien, P.; Caille, J.M.; Bonnemain, B.; Frija, G.

    1986-01-01

    To evaluate the paramagnetic properties of a new gadolinium chelate, Gd-DOTA, in vitro and in vivo MR imaging was performed with a 0.5-T supraconductive magnet. The in vitro study consisted in measuring the MR signal obtained with various concentrations of Gd-DOTA and Gd-DTPA in different solutions. Potentialization of the paramagnetic properties of both DOTA and DTPA can be achieved by deuterium, glycerol, and protein solutions. The in vivo study was performed in rabbits with various experimental lesions. Enhancement of anatomic details was obtained with both Gd-DOTA and Gd-DTPA. There was no significant difference between Gd-DOTA and Gd-DTPA, both for in vitro and in vivo experiments. Gd-DOTA appears to be a potential paramagnetic agent for MR imaging

  2. Effect of Al{sub 2}Gd on microstructure and properties of laser clad Mg–Al–Gd coatings

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hong; Zhang, Ke; Yao, Chengwu [Shanghai Key Lab of Materials Laser Processing and Modification, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Dong, Jie [National Engineering Research Center of Light Alloy Net Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Li, Zhuguo, E-mail: lizg@sjtu.edu.cn [Shanghai Key Lab of Materials Laser Processing and Modification, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Emmelmann, Claus [Institute of Laser and System Technologies, Hamburg University of Technology, Hamburg, 21073 (Germany)

    2015-03-01

    Highlights: • Mg–Al–Gd coatings with different Gd contents were fabricated by fiber laser cladding. • Chemical compositions and crystal structures of the second phases were characterized. • Dispersion of Al{sub 2}Gd led to further grain refining and elevated mechanical properties. • Al{sub 2}Gd improved high-temperature performances by preventing tiny liquation. - Abstract: In order to investigate the effects of Gd addition on the microstructures and properties of magnesium coatings, the Mg–7.5Al–xGd (x = 0, 2.5, 5.0 and 7.5 wt.%) coatings on cast magnesium alloy were fabricated by laser cladding with wire feeding. The results indicated that the gadolinium (Gd) addition led to the formation of a cubic Al{sub 2}Gd phase as well as suppressed the precipitation of eutectic Mg{sub 17}Al{sub 12} phase. The laser clad coating containing nominally 7.5 wt.% Gd presented the highest microhardness, ultimate tensile strength and yield strength at both room temperature and high temperatures. The enhancement of heat resistant capacities was chiefly attributed to the existence of thermally stable Al{sub 2}Gd particles, which prevented tiny liquation of eutectic phases along the grain boundaries and made great contributions on maintaining high yield ratio during high-temperature deformation.

  3. Pharmacokinetic analysis of Gd-DTPA enhancement in dynamic MR of breast carcinoma

    International Nuclear Information System (INIS)

    Hess, T.; Knopp, M.V.; Hoffmann, U.; Brix, G.; Junkermann, H.; Zuna, I.; Fournier, D. von; Kaick, G. van

    1994-01-01

    Dynamic Gd-DTPA enhanced MR of the breast was performed in one single slice in 27 patients with suspicious nodular lesions. The results could be histologically verified in all cases. A rapid spin-echo sequence with a time resolution of 8.75 s was used for the dynamic examination. The signal changes were analysed using a pharmacokinetic model which allowed parametrization of the contrast enhancement and transformation of the data into colour coded parameter images. The parameters allowed reliable distinction of 9 benign from 18 malignant lesions (p 21 ''). One fibroadenoma could not be distinguished from the carcinomas. Lymph node metastases and the pharmacokinetic parameter amplitude correlated significantly (p<0.05). (orig.)

  4. Mechanism of luminescent enhancement in Ba{sub 2}GdNbO{sub 6}:Eu{sup 3+} perovskite by Li{sup +} co-doping

    Energy Technology Data Exchange (ETDEWEB)

    Rezende, Marcos Vinicius dos Santos [Departamento de Física, Universidade Federal de Sergipe, 49500-000, Itabaiana, SE (Brazil); Valério, Mario Ernesto Giroldo [Departamento de Física, Universidade Federal de Sergipe, 49100-000 São Cristóvão, SE (Brazil); Mouta, Rodolpho; Diniz, Eduardo Moraes [Departamento de Física, CCET, Universidade Federal do Maranhão, 65085-580 São Luís, MA (Brazil); Paschoal, Carlos William de Araujo, E-mail: paschoal@ufma.br [Departamento de Física, CCET, Universidade Federal do Maranhão, 65085-580 São Luís, MA (Brazil); Department of Materials Science and Engineering, University of California Berkeley, 94720-1760 Berkeley, CA (United States); Department of Physics, University of California Berkeley, 94720-7300 Berkeley, CA (United States)

    2015-02-15

    We investigated the Li{sup +} ion incorporation in Ba{sub 2}GdNbO{sub 6}:Eu{sup 3+} perovskite by atomistic simulations based on energy minimization. We predicted the most probable sites occupied by Eu{sup 3+} and Li{sup +} ions and the related charge-compensation mechanisms involved into these substitutions. The results show that the Eu{sup 3+} and Li{sup +} ions are incorporated mainly at the Gd{sup 3+} site. In the Li{sup +} ion case, there is a charge compensation by Nb{sub Gd}{sup •} {sup •} antisite. The crystal field parameters and the transition levels for the Eu{sup 3+} ion in the BGN:Eu{sup 3+} were calculated with basis on the simulated local symmetry of the Eu{sup 3+} site. The results show that the mechanism of luminescent properties enhancement is the symmetry distortion induced by the Li{sup +} co-doping. - Highlights: • We performed a full defect calculations in Ba{sub 2}GdNbO{sub 6} double perovskite. • We modeled with excellent agreement the optical transition of Ba{sub 2}GdNbO{sub 6}:Eu{sup 3+} crystal. • We explained the mechanism of luminescent enhancement in Ba{sub 2}GdNbO{sub 6}:Eu{sup 3+} perovskite by Li{sup +} co-doping.

  5. STREAMFINDER II: A possible fanning structure parallel to the GD-1 stream in Pan-STARRS1

    Science.gov (United States)

    Malhan, Khyati; Ibata, Rodrigo A.; Goldman, Bertrand; Martin, Nicolas F.; Magnier, Eugene; Chambers, Kenneth

    2018-05-01

    STREAMFINDER is a new algorithm that we have built to detect stellar streams in an automated and systematic way in astrophysical datasets that possess any combination of positional and kinematic information. In Paper I, we introduced the methodology and the workings of our algorithm and showed that it is capable of detecting ultra-faint and distant halo stream structures containing as few as ˜15 members (ΣG ˜ 33.6 mag arcsec-2) in the Gaia dataset. Here, we test the method with real proper motion data from the Pan-STARRS1 survey, and by selecting targets down to r0 = 18.5 mag we show that it is able to detect the GD-1 stellar stream, whereas the structure remains below a useful detection limit when using a Matched Filter technique. The radial velocity solutions provided by STREAMFINDER for GD-1 candidate members are found to be in good agreement with observations. Furthermore, our algorithm detects a ˜ {40}° long structure approximately parallel to GD-1, and which fans out from it, possibly a sign of stream-fanning due to the triaxiality of the Galactic potential. This analysis shows the promise of this method for detecting and analysing stellar streams in the upcoming Gaia DR2 catalogue.

  6. Gd-EOB-DTPA-enhanced MRI for monitoring future liver remnant function after portal vein embolization and extended hemihepatectomy: A prospective trial.

    Science.gov (United States)

    Geisel, Dominik; Raabe, Philip; Lüdemann, Lutz; Malinowski, Maciej; Stockmann, Martin; Seehofer, Daniel; Pratschke, Johann; Hamm, Bernd; Denecke, Timm

    2017-07-01

    To evaluate changes in liver function after right portal vein embolization (PVE) and extended right hemihepatectomy using gadolinium ethoxybenzyl-DTPA-enhanced (Gd-EOB-DTPA) MRI. In this prospective trial, 37 patients undergoing PVE were examined before and 14 and 28 days after PVE and 10 days after extended hemihepatectomy using Gd-EOB-DTPA-enhanced MRI. Lobar volume, kinetic growth rate (KGR), relative enhancement (RE) as well as hepatocellular uptake index (HUI) and fat signal fraction (FSF) were calculated for each lobe. RE of the left liver lobe (LLL) was steadily increasing after PVE and decreased to 0.48 ± 0.19 10 days after surgery, which is significantly lower than 14 days and 28 days post PVE (P DTPA-enhanced MRI may be used to monitor the functional increase in the FLR after PVE and to depict the intraoperative liver injury leading to a decrease in liver remnant function. • The most significant FLR volume increase happens within the first 14 days. • No MRI parameter was able to predict the success of FLR growth. • Our data suggest an early resection about 14 days after PVE. • Routine Gd-EOB-DTPA-enhanced MRI might be suitable to replace ICG-test.

  7. Marginal erosive discovertebral ''Romanus'' lesions in ankylosing spondylitis demonstrated by contrast enhanced Gd-DTPA magnetic resonance imaging

    International Nuclear Information System (INIS)

    Jevtic, V.; Kos-Golja, M.; Rozman, B.; McCall, I.

    2000-01-01

    Objective. To assess the value of Gd-DTPA magnetic resonance (MR) imaging in the demonstration of marginal destructive discovertebral Romanus lesions in ankylosing spondylitis.Design and patients. A prospective study of Gd-DTPA MR imaging was performed in 39 patients with a clinical diagnosis of ankylosing spondylitis and typical Romanus lesions seen on radiographs of the thoracolumbar spine. MR morphological appearances and signal intensity changes at the discovertebral junctions were analysed and compared with the radiographic findings.Results. Ninety-nine discovertebral junctions with Romanus lesions showed low signal intensity on T1-weighted and high signal on T2-weighted and T1-weighted postcontrast images at the vertebral corners consistent with oedematous hyperaemic inflammatory tissue. There were nine discovertebral junctions with similar MR findings but normal radiographs. Fifty-three discovertebral junctions showed syndesmophyte formation with increased signal intensity on both T1- and T2-weighted images with no contrast enhancement. Sixty-five discovertebral junctions showed a mixture of radiographic features and varied high and low signal changes at the vertebral rim on MR imaging with rims of enhancement in the vertebral body following contrast administration.Conclusion. Gd-DTPA MR imaging demonstrates a variable signal pattern and degree of contrast enhancement which may reflect the evolutionary stages of discovertebral enthesitis in ankylosing spondylitis. MR imaging may identify early erosive changes in radiographically normal vertebra. The role of MR imaging needs further investigation. (orig.)

  8. MR lymphography with macromolecular Gd-DTPA compounds

    International Nuclear Information System (INIS)

    Hamm, B.; Wagner, S.; Branding, G.; Taupitz, M.; Wolf, K.J.

    1990-01-01

    This paper investigates the suitability of macromolecular Gd-DTPA compounds as signal-enhancing lymphographic agents in MR imaging. Two Gd-DTPA polylysin compounds and Gd-DTPA albumin, with molecular weights of 48,000,170,000, and 87,000 daltons, respectively, were tested in rabbits at gadolinium doses of 5 and 15 μmol per animal. Three animals were examined at each dose with T1-weighted sequences. The iliac lymph nodes were imaged prior to and during unilateral endolymphatic infusion into a femoral lymph vessel as well as over a period of 2 hours thereafter. All contrast media showed a homogeneous and pronounced signal enhancement in the lymph nodes during infusion at both doses

  9. MR imaging of the breast with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Hachiya, Junichi; Seki, Tsuneaki; Okada, Minoru; Nitatori, Toshiaki; Korenaga, Tateo; Furuya, Yoshiro

    1991-01-01

    The accuracy of MR imaging with Gd-DTPA enhancement was compared with mammography and ultrasonography in 52 patients with clinically palpable benign and malignant breast masses (36 carcinomas, 2 malignant phyllodes tumors, 7 fibroadenomas, 7 cysts). On dynamic MR imaging, carcinomas and fibroadenomas were discriminated by their different dynamic enhancement profiles. In carcinomas, signal intensity increased rapidly, reaching a peak or plateau within 2 min after the injection of contrast medium. In fibroadenomas, signal intensity showed a much slower continuous increase without ceasing until about 8 min after injection. Malignant phyllodes tumors showed a dynamic enhancement profile identical to that of benign fibroadenomas. MR imaging correctly identified 84% of malignant tumors, 86% of fibroadenomas, and 100% of cysts, and was substantially more accurate in tissue characterization than mammography. The results of ultrasonography were highly similar to those of MR imaging. However, no single modality was infallible, and the three modalities were complementary rather than competitive. Considering the high cost and long examination time of MR imaging, mammography supplemented by ultrasonography seems to be the method of choice in the diagnosis of breast lesions. Nevertheless, MR imaging can add important information when the results of mammography and ultrasonography are insufficient or contradictory. (author)

  10. Intraindividual comparison of T1 relaxation times after gadobutrol and Gd-DTPA administration for cardiac late enhancement imaging

    Energy Technology Data Exchange (ETDEWEB)

    Doeblin, Patrick, E-mail: Patrick.doeblin@charite.de [Department of Cardiology, Charité – Universitätsmedizin Berlin, Charité Campus Benjamin Franklin, Berlin (Germany); Schilling, Rene, E-mail: rene.schilling@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Wagner, Moritz, E-mail: moritz.wagner@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Luhur, Reny, E-mail: renyluhur@yahoo.com [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Huppertz, Alexander, E-mail: alexander.huppertz@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Imaging Science Institute, Charité, Berlin (Germany); Hamm, Bernd, E-mail: bernd.hamm@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Taupitz, Matthias, E-mail: matthias.taupitz@harite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); and others

    2014-04-15

    Purpose: To evaluate T1-relaxation times of chronic myocardial infarction (CMI) using gadobutrol and gadopentetate dimeglumine (Gd-DTPA) over time and to determine the optimal imaging window for late enhancement imaging with both contrast agents. Material and methods: Twelve patients with CMI were prospectively included and examined on a 1.5 T magnetic resonance (MR) system using relaxivity-adjusted doses of gadobutrol (0.15 mmol/kg) and Gd-DTPA (0.2 mmol/kg) in random order. T1-relaxation times of remote myocardium (RM), infarcted myocardium (IM), and left ventricular cavity (LVC) were assessed from short-axis TI scout imaging using the Look–Locker approach and compared intraindividually using a Wilcoxon paired signed-rank test (α < 0.05). Results: Within 3 min of contrast agent administration (CA), IM showed significantly lower T1-relaxation times than RM with both contrast agents, indicating beginning cardiac late enhancement. Differences between gadobutrol and Gd-DTPA in T1-relaxation times of IM and RM were statistically not significant through all time points. However, gadobutrol led to significantly higher T1-relaxation times of LVC than Gd-DTPA from 6 to 9 min (220 ± 15 ms vs. 195 ± 30 ms p < 0.01) onwards, resulting in a significantly greater ΔT1 of IM to LVC at 9–12 min (−20 ± 35 ms vs. 0 ± 35 ms, p < 0.05) and 12–15 min (−25 ± 45 ms vs. −10 ± 60 ms, p < 0.05). Using Gd-DTPA, comparable ΔT1 values were reached only after 25–35 min. Conclusion: This study indicates good delineation of IM to RM with both contrast agents as early as 3 min after administration. However, we found significant differences in T1 relaxation times with greater ΔT1 IM–LVC using 0.15 mmol/kg gadobutrol compared to 0.20 mmol/kg Gd-DTPA after 9–15 min post-CA suggesting earlier differentiability of IM and LVC using gadobutrol.

  11. The enhanced activity of mass-selected PtxGd nanoparticles for oxygen electroreduction

    DEFF Research Database (Denmark)

    Velazquez-Palenzuela, Amado Andres; Masini, Federico; Pedersen, Anders Filsøe

    2015-01-01

    Mass-selected platinum–gadolinium alloy nanoparticles (PtxGd NPs) are synthesized for the first time as oxygen reduction reaction (ORR) electrocatalysts using the gas aggregation technique, under ultrahigh vacuum (UHV) conditions. The morphology of the PtxGd catalysts is characterized, and their ......Mass-selected platinum–gadolinium alloy nanoparticles (PtxGd NPs) are synthesized for the first time as oxygen reduction reaction (ORR) electrocatalysts using the gas aggregation technique, under ultrahigh vacuum (UHV) conditions. The morphology of the PtxGd catalysts is characterized...

  12. Comparison of two brain tumor-localizing MRI agent. GD-BOPTA and GD-DTPA. MRI and ICP study of rat brain tumor model

    International Nuclear Information System (INIS)

    Zhang, T.; Matsumura, A.; Yamamoto, T.; Yoshida, F.; Nose, T.

    2000-01-01

    In this study, we compared the behavior of Gd-BOPTA as a brain tumor selective contrast agent with Gd-DTPA in a common dose of 0.1 mmol/kg. We performed a MRI study using those two agent as contrast material, and we measured tissue Gd-concentrations by ICP-AES. As a result, Gd-BOPTA showed a better MRI enhancement in brain tumor. ICP showed significantly greater uptake of Gd-BOPTA in tumor samples, at all time course peaked at 5 minutes after administration, Gd being retained for a longer time in brain tumor till 2 hours, without rapid elimination as Gd-DTPA. We conclude that Gd-BOPTA is a new useful contrast material for MR imaging in brain tumor and an effective absorption agent for neutron capture therapy for further research. (author)

  13. Ultra-long-term human salt balance studies reveal interrelations between sodium, potassium, and chloride intake and excretion.

    Science.gov (United States)

    Birukov, Anna; Rakova, Natalia; Lerchl, Kathrin; Engberink, Rik Hg Olde; Johannes, Bernd; Wabel, Peter; Moissl, Ulrich; Rauh, Manfred; Luft, Friedrich C; Titze, Jens

    2016-07-01

    The intake of sodium, chloride, and potassium is considered important to healthy nutrition and cardiovascular disease risk. Estimating the intake of these electrolytes is difficult and usually predicated on urine collections, commonly for 24 h, which are considered the gold standard. We reported on data earlier for sodium but not for potassium or chloride. We were able to test the value of 24-h urine collections in a unique, ultra-long-term balance study conducted during a simulated trip to Mars. Four healthy men were observed while ingesting 12 g salt/d, 9 g salt/d, and 6 g salt/d, while their potassium intake was maintained at 4 g/d for 105 d. Six healthy men were studied while ingesting 12 g salt/d, 9 g salt/d, and 6 g salt/d, with a re-exposure of 12 g/d, while their potassium intake was maintained at 4 g/d for 205 d. Food intake and other constituents were recorded every day for each subject. All urine output was collected daily. Long-term urine recovery rates for all 3 electrolytes were very high. Rather than the expected constant daily excretion related to daily intake, we observed remarkable daily variation in excretion, with a 7-d infradian rhythm at a relatively constant intake. We monitored 24-h aldosterone excretion in these studies and found that aldosterone appeared to be the regulator for all 3 electrolytes. We report Bland-Altman analyses on the value of urine collections to estimate intake. A single 24-h urine collection cannot predict sodium, potassium, or chloride intake; thus, multiple collections are necessary. This information is important when assessing electrolyte intake in individuals. © 2016 American Society for Nutrition.

  14. Influence of the size of Gd211 starting powder on the critical current density of Gd-Ba-Cu-O bulk superconductor

    International Nuclear Information System (INIS)

    Nariki, S.; Seo, S.J.; Sakai, N.; Murakami, M.

    2000-01-01

    The relationship between the particle size of Gd211 powder in the precursor and the particle size of Gd211 inclusions in Gd-Ba-Cu-O bulk has been investigated. Gd211 starting powders with various diameters were prepared by the calcination of Gd 2 O 3 , BaO 2 and CuO powders at different temperatures between 800 and 1000 deg. C. The particle size of Gd211 in the melt-grown bulk was proportional to the particle size of the initial Gd211 powder. In conclusion, the employment of fine Gd211 powder led to a size reduction of 211 particles in the bulk, while largely enhancing the J c values in low magnetic fields. A large Gd-Ba-Cu-O/Ag bulk sample, 32 mm in diameter, could also be fabricated by the hot-seeding method. The maximum trapped field value revealed 1.5 T at 77 K. (author)

  15. Value of contrast enhancement with Gd-DTPA in MRI of brain tumors. A comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Tsuji, Takehisa; Kishikawa, Takashi; Ikezaki, Kiyonobu; Fujii, Kiyotaka; Matsumoto, Shunichi; Koga, Toshihiko.

    1987-12-01

    Value of administration of Gadolinium-DTPA dimeglumine (Gd-DTPA), a magnetic resonance contrast agent, in MRI was evaluated in 17 patients of primary brain tumors and 3 metastatic tumors with known pathology, comparing with CT findings. MRI was performed with T/sub 1/-weighted spin echo pulse sequence (SE 50030) prior to and following the intravenous injection of 0.10 mmolkg Gd-DTPA. All, but one pituitary microadenoma, the tumors including meningiomas, pituitary adenomas, gliomas, intraventricular craniopharyngioma and acoustic neurinoma and metastatic lung adenocarcinomas, were enhanced by Gd-DTPA on T/sub 1/-weighted images. Good definition of the exact boundaries and extent of the mass to the surrounding structures were obtained in all these cases. Especially, the invasion of meningioma to the dura mater or to the venous sinus, and that of cerebellopontine angle tumor to the internal auditory meatus or to the jugular foramen, were better delineated on MRI as compared with CT. The anatomical relationship to the surrounding structures in the sellar or parasellar tumors were also clearly demonstrated on MRI. Thus, MRI with Gd-DTPA administration was useful for the preoperative assessment and Gd-DTPA appears to be a safe contrast agent for MRI since there were no significant untoward reactions in our series.

  16. Luminescent GdVO{sub 4}:Sm{sup 3+} quantum dots enhance power conversion efficiency of bulk heterojunction polymer solar cells by Förster resonance energy transfer

    Energy Technology Data Exchange (ETDEWEB)

    Bishnoi, Swati [CSIR-Network of Institutes for Solar Energy, New Delhi 110001 (India); Luminescent Materials and Devices Group, CSIR-National Physical Laboratory, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012 (India); Gupta, Vinay, E-mail: drvinaygupta@netscape.net; Sharma, Gauri D.; Chand, Suresh [CSIR-Network of Institutes for Solar Energy, New Delhi 110001 (India); Organic and Hybrid Solar Cells Group, Physics of Energy Harvesting Division, CSIR-National Physical Laboratory, New Delhi 110012 (India); Sharma, Chhavi; Kumar, Mahesh [Ultrafast Optoelectronics and Terahertz Photonics Lab, Physics of Energy Harvesting Division, CSIR-National Physical Laboratory, New Delhi 110012 (India); Haranath, D. [CSIR-Network of Institutes for Solar Energy, New Delhi 110001 (India); Luminescent Materials and Devices Group, CSIR-National Physical Laboratory, New Delhi 110012 (India); Naqvi, Sheerin [Luminescent Materials and Devices Group, CSIR-National Physical Laboratory, New Delhi 110012 (India)

    2016-07-11

    In this work, we report enhanced power conversion efficiency (PCE) of bulk heterojunction polymer solar cells by Förster resonance energy transfer (FRET) from samarium-doped luminescent gadolinium orthovanadate (GdVO{sub 4}:Sm{sup 3+}) quantum dots (QDs) to polythieno[3,4-b]-thiophene-co-benzodithiophene (PTB7) polymer. The photoluminescence emission spectrum of GdVO{sub 4}:Sm{sup 3+} QDs overlaps with the absorption spectrum of PTB7, leading to FRET from GdVO{sub 4}:Sm{sup 3+} to PTB7, and significant enhancements in the charge-carrier density of excited and polaronic states of PTB7 are observed. This was confirmed by means of femtosecond transient absorption spectroscopy. The FRET from GdVO{sub 4}:Sm{sup 3+} QDs to PTB7 led to a remarkable increase in the power conversion efficiency (PCE) of PTB7:GdVO{sub 4}:Sm{sup 3+}:PC{sub 71}BM ([6,6]-phenyl-C{sub 71}-butyric acid methyl ester) polymer solar cells. The PCE in optimized ternary blend PTB7:GdVO{sub 4}:Sm{sup 3+}:PC{sub 71}BM (1:0.1:1.5) is increased to 8.8% from 7.2% in PTB7:PC{sub 71}BM. This work demonstrates the potential of rare-earth based luminescent QDs in enhancing the PCE of polymer solar cells.

  17. Gd-EOB-DTPA-enhanced MRI for monitoring future liver remnant function after portal vein embolization and extended hemihepatectomy: A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Raabe, Philip; Hamm, Bernd; Denecke, Timm [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Luedemann, Lutz [Essen University Hospital, Department of Medical Physics, Essen (Germany); Malinowski, Maciej; Stockmann, Martin; Seehofer, Daniel; Pratschke, Johann [Charite Campus Virchow-Klinikum, Department of General, Visceral and Transplantation Surgery, Berlin (Germany)

    2017-07-15

    To evaluate changes in liver function after right portal vein embolization (PVE) and extended right hemihepatectomy using gadolinium ethoxybenzyl-DTPA-enhanced (Gd-EOB-DTPA) MRI. In this prospective trial, 37 patients undergoing PVE were examined before and 14 and 28 days after PVE and 10 days after extended hemihepatectomy using Gd-EOB-DTPA-enhanced MRI. Lobar volume, kinetic growth rate (KGR), relative enhancement (RE) as well as hepatocellular uptake index (HUI) and fat signal fraction (FSF) were calculated for each lobe. RE of the left liver lobe (LLL) was steadily increasing after PVE and decreased to 0.48 ± 0.19 10 days after surgery, which is significantly lower than 14 days and 28 days post PVE (P < 0.05). KGR was 14.06 ± 9.82%/week for the period from PVE to 14 days after PVE. HUI of the LLL increased steadily after PVE and was significantly higher at both 14 and 28 days after PVE compared to pre PVE (P < 0.05). HUI of the residual liver after surgery was lower than before. Gd-EOB-DTPA-enhanced MRI may be used to monitor the functional increase in the FLR after PVE and to depict the intraoperative liver injury leading to a decrease in liver remnant function. (orig.)

  18. Gd-DTPA in MRI. Clinical experience in intracranial pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Bradac, G B; Riva, A; Berger, T; Stura, G; Duca, S

    1988-01-01

    Sixty-seven patients with various intracranial pathologies were studied using Gd-DTPA as a contrast medium applied to MRI. This paramagnetic substance was well tolerated by all patients, and proved particularly useful in improving the diagnosis of extra-axial tumors, in which a rich enhancement was always present. Gd-DTPA allowed a better definition of the tumor outlines, as well as its differentiation from edema, and the demonstration of its relationship to brain parenchyma and cerebral vessels. This was particularly true for meningiomas, which often display poor contrast enhancement at MRI. Even though acoustic neuromas had, as a rule, high signal intensity, Gd-DTPA was useful to precisely recognise the intracanalar part of the tumor. The value of Gd-DTPA was less evident in intra-axial lesions. It proved nonetheless useful in demonstrating the portions of the tumor where, due to alterations in BBB, enhancement was present. This allowed both to characterized the lesion and to perform accurate biopsies.

  19. Enhanced vasculotoxic metal excretion in post-myocardial infarction patients following a single edetate disodium-based infusion.

    Science.gov (United States)

    Arenas, Ivan A; Navas-Acien, Ana; Ergui, Ian; Lamas, Gervasio A

    2017-10-01

    Toxic metals have been associated with cardiovascular mortality and morbidity. We have hypothesized that enhanced excretion of vasculotoxic metals might explain the positive results of the Trial to Assess Chelation Therapy (TACT). The purpose of this study was to determine whether a single infusion of the edetate disodium- based infusion used in TACT led to enhanced excretion of toxic metals known to be associated with cardiovascular events. Twenty six patients (post-MI, age > 50 years, serum creatinine ≤ 2.0mg/dL) were enrolled in this open-label study. Urinary levels of 20 toxic metals normalized to urinary creatinine concentrations were measured at baseline in overnight urine collections, for 6h following a placebo infusion of 500mL normal saline and 1.2% dextrose, and for 6h following a 3g edetate disodium-based infusion. Self-reported metal exposure, smoking status, food frequency, occupational history, drinking water source, housing and hobbies were collected at baseline by a metal exposure questionnaire. The mean age was 65 years (range 51-81 years). All patients were male. 50% had diabetes mellitus and 58% were former smokers. Mean (SD) serum creatinine was 0.95 (0.31) mg/dL. Toxic metals were detected in the baseline urine of >80% of patients. After placebo infusion there were no significant changes in total urinary metal levels. After edetate infusion, total urinary metal level increased by 71% compared to baseline (1500 vs. 2580µg/g creatinine; P<0.0001). The effect of edetate was particularly large for lead (3835% increase) and cadmium (633% increase). Edetate disodium-based infusions markedly enhanced the urinary excretion of lead and cadmium, toxic metals with established epidemiologic evidence and mechanisms linking them to coronary and vascular events. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Advantages of gadobenate dimeglumine-enhanced MR cholangiography in the diagnosis of post-liver transplant bile leakage.

    Science.gov (United States)

    Fontarensky, M; Montoriol, P-F; Buc, E; Poincloux, L; Petitcolin, V; Da Ines, D

    2013-04-01

    To assess the value of magnetic resonance cholangiography with gadobenate dimeglumine (Gd-BOPTA) where there is a suspicion of bile leakage in the post-liver transplant patient. Eight patients who had undergone a liver transplant underwent 14 MR cholangiograms, five of whom presented bile leakage while the other three had no biliary system complications. The results were compared to conventional bile duct opacification (by endoscopy or t-tube cholangiogram). The analysis covered whether there was opacification of the common bile duct and intrahepatic bile ducts on T1-weighted sequences after an injection of Gd-BOPTA on delayed biliary excretion phase sequences that were carried out on average 74 min after the injection. Enhancing perihepatic collections were also taken into account. Opacification of the bile ducts on delayed-phase MR cholangiogram sequences was always seen in the absence of bile leakage, and was never found when leakage was present. Enhancing perihepatic collections pointed to bile leakage every time. Gd-BOPTA-enhanced MR cholangiography is a simple and non-invasive technique for detecting bile leakage in the post-liver transplant patient. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  1. Haemophilic arthropathy of the knee. Gd-DTPA enhanced MRT. Clinical and radiological correlation

    International Nuclear Information System (INIS)

    Naegele, M.; Kunze, V.; Hamann, M.; Eickhoff, H.; Koch, W.; Oldenburg, J.; Reiser, M.

    1994-01-01

    17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRT before and after i.v. bolus injection of Gadolinium-DTPA (0,1 mmol/kg body weight). After contrast enhancement, synovial proliferations exhibited an increase of signal intensity (SI) of FFE and SE images of 47.7% and 37.4% respectively, whereas muscle and fatty tissue, tendons, bone marrow and joint effusion revealed only minor increase in SI. The gradient of signal intensity (ratio SI/time) of pannus was 39,6% min. Gd-DTPA enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.) [de

  2. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja, E-mail: Sonja.Kinner@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Steinweg, Verena [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Maderwald, Stefan [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Radtke, Arnold; Sotiropoulos, Georgios [Department of General Surgery, University Hospital Essen (Germany); Forsting, Michael; Schroeder, Tobias [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany)

    2014-05-15

    Introduction: Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC). Materials and methods: 30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w ± IR) were acquired 20–30 min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann–Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated. Results: All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference. Conclusions: Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR.

  3. Ultra-long–term human salt balance studies reveal interrelations between sodium, potassium, and chloride intake and excretion12

    Science.gov (United States)

    Birukov, Anna; Rakova, Natalia; Lerchl, Kathrin; Engberink, Rik HG Olde; Johannes, Bernd; Wabel, Peter; Moissl, Ulrich; Rauh, Manfred; Luft, Friedrich C; Titze, Jens

    2016-01-01

    Background: The intake of sodium, chloride, and potassium is considered important to healthy nutrition and cardiovascular disease risk. Estimating the intake of these electrolytes is difficult and usually predicated on urine collections, commonly for 24 h, which are considered the gold standard. We reported on data earlier for sodium but not for potassium or chloride. Objective: We were able to test the value of 24-h urine collections in a unique, ultra-long–term balance study conducted during a simulated trip to Mars. Design: Four healthy men were observed while ingesting 12 g salt/d, 9 g salt/d, and 6 g salt/d, while their potassium intake was maintained at 4 g/d for 105 d. Six healthy men were studied while ingesting 12 g salt/d, 9 g salt/d, and 6 g salt/d, with a re-exposure of 12 g/d, while their potassium intake was maintained at 4 g/d for 205 d. Food intake and other constituents were recorded every day for each subject. All urine output was collected daily. Results: Long-term urine recovery rates for all 3 electrolytes were very high. Rather than the expected constant daily excretion related to daily intake, we observed remarkable daily variation in excretion, with a 7-d infradian rhythm at a relatively constant intake. We monitored 24-h aldosterone excretion in these studies and found that aldosterone appeared to be the regulator for all 3 electrolytes. We report Bland–Altman analyses on the value of urine collections to estimate intake. Conclusions: A single 24-h urine collection cannot predict sodium, potassium, or chloride intake; thus, multiple collections are necessary. This information is important when assessing electrolyte intake in individuals. PMID:27225435

  4. Synthesis and functionalization of NaGdF4:Yb,Er@NaGdF4 core–shell nanoparticles for possible application as multimodal contrast agents

    Directory of Open Access Journals (Sweden)

    Dovile Baziulyte-Paulaviciene

    2017-09-01

    Full Text Available Upconverting nanoparticles (UCNPs are promising, new imaging probes capable of serving as multimodal contrast agents. In this study, monodisperse and ultrasmall core and core–shell UCNPs were synthesized via a thermal decomposition method. Furthermore, it was shown that the epitaxial growth of a NaGdF4 optical inert layer covering the NaGdF4:Yb,Er core effectively minimizes surface quenching due to the spatial isolation of the core from the surroundings. The mean diameter of the synthesized core and core–shell nanoparticles was ≈8 and ≈16 nm, respectively. Hydrophobic UCNPs were converted into hydrophilic ones using a nonionic surfactant Tween 80. The successful coating of the UCNPs by Tween 80 has been confirmed by Fourier transform infrared (FTIR spectroscopy. Scanning electron microscopy (SEM, powder X-ray diffraction (XRD, photoluminescence (PL spectra and magnetic resonance (MR T1 relaxation measurements were used to characterize the size, crystal structure, optical and magnetic properties of the core and core–shell nanoparticles. Moreover, Tween 80-coated core–shell nanoparticles presented enhanced optical and MR signal intensity, good colloidal stability, low cytotoxicity and nonspecific internalization into two different breast cancer cell lines, which indicates that these nanoparticles could be applied as an efficient, dual-modal contrast probe for in vivo bioimaging.

  5. Accumulation of Bile in the Gallbladder: Evaluation by means of Serial Dynamic Contrast-Enhanced Magnetic Resonance Cholangiography with Gadolinium Ethoxybenzyl Diethylenetriaminepentaacetic Acid

    Directory of Open Access Journals (Sweden)

    Tsutomu Tamada

    2014-01-01

    Full Text Available The aim of this study was to evaluate the process of biliary excretion of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA into the biliary tract and to assess the accumulation patterns in the gallbladder using MR cholangiography obtained with Gd-EOB-DTPA which is a liver-specific hepatobiliary contrast agent. Seventy-five patients underwent Gd-EOB-DTPA enhanced MR imaging. Serial multiphasic hepatobiliary phase imaging was qualitatively reviewed to evaluate the process of the biliary excretion of contrast agent into the bile duct and the gallbladder. The accumulation pattern of contrast agent into gallbladder was classified into two groups (group 1 = orthodromic type and group 2 = delayed type. Furthermore, the results in differences of the presence of T1 hyperintense bile or sludge of gallbladder, gall stones, wall thickening of gallbladder, chronic liver disease, and liver cirrhosis between two groups were compared. Forty-eight of 75 patients (64% were included in group 1, and remaining 27 (36% were in group 2. The frequency of the presence of T1 hyperintense bile or sludge of gallbladder was significantly higher in patients with group 2 than that in patients with group 1 (P=0.041. MR cholangiography obtained with Gd-EOB-DTPA showed that there may be an association between the biliary accumulation pattern in the gallbladder and the pathological condition.

  6. Detection of active bile leak with Gd-EOB-DTPA enhanced MR cholangiography: Comparison of 20–25 min delayed and 60–180 min delayed images

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Stadnik, Anna; Lezak, Aleksandra; Maj, Edyta; Zieniewicz, Krzysztof; Rowinska-Berman, Katarzyna; Grudzinski, Ireneusz P.; Krawczyk, Marek; Rowiński, Olgierd

    2013-01-01

    Objectives: The purpose of this study was to assess the value of contrast-enhanced magnetic resonance cholangiography (MRC) performed in different time delays after injection of gadoxetic acid disodium (Gd-EOB-DTPA) for the diagnosis of active bile leak. Methods: This retrospective analysis included Gd-EOB-DTPA enhanced MR images of 34 patients suspected of bile leak. Images were acquired 20–25 min after Gd-EOB-DTPA injection. If there was inadequate contrast in the bile ducts then delayed images after 60–90 min and 150–180 min were obtained. Results were correlated with intraoperative findings, ERCP results, clinical data, laboratory tests, and follow-up examinations. Results: Gd-EOB-DTPA enhanced MRC yielded an overall sensitivity of 96.4%, specificity of 100% and accuracy of 97.1% for the diagnosis of an active bile leak. The sensitivity of 20–25 min delayed MR images was 42.9%, of combined 20–25 min and 60–90 min delayed images was 92.9% and of combined 20–25 min, 60–90 min and 150–180 min delayed images was 96.4%. Conclusions: Gd-EOB-DTPA enhanced MRC utilizing delayed phase images was effective for detecting the presence and location of active bile leaks. The images acquired 60–180 min post-injection enabled identification of bile leaks even in patients with a dilated biliary system or moderate liver dysfunction

  7. Demonstration of evolution of hemispherical spondysclerosis by contrast enhanced Gd-DTPA magnetic resonance imaging

    International Nuclear Information System (INIS)

    Jevtic, V.; Majcen, N.

    2004-01-01

    Background. The purpose of the study was to estimate the value of Gd-DTPA magnetic resonance imaging (MRI) in demonstrating the evolution of hemispherical spondylosclerosis (HSS). Patients and methods. In eighteen patients with chronic low back pain and typical radiographic findings of HSS seen on plain films, Gd-DTPA MRI of the lumbar spine was performed. MRI morphological and signal intensity appearances of HSS were analysed and compared with radiographic changes. Results. On the basis of MRI features, three distinct groups of cases were identifiable. Within the first group the region of dome-shaped osteosclerosis demonstrated low signal intensity on T1-weighted precontrast spin-echo images, high signal intensity on T2-weighted images and diffuse contrast enhancement on T1-weighted postcontrast images, findings compatible with bone marrow oedema and hyperaemia. The second group showed high signal intensity vertebral body corners surrounded by low signal intensity area, which indicated the combination of fat accumulation and the sclerotic bone. In the third intermediate group anterior disco-vertebral junctions revealed a mixture of MRI appearances characteristic of the first and the second group. Conclusions. Gd-DTPA MRI is capable of demonstrating a spectrum of features which reflect the evolution of HSS. These typical appearances showed by MRI could be of eventual clinical relevance in following the progression of HSS. (author)

  8. Enhanced photoluminescence of Sm{sup 3+}/Bi{sup 3+} co-doped Gd{sub 2}O{sub 3} phosphors by combustion synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Liu Guangsheng; Zhang Ying [Institute of Micro-system Physics, School of Physics and Electronics, Henan University, Kaifeng 475001 (China); Yin Jiang [Department of Physics, Nanjing University, Nanjing 210093 (China); Zhang, W.F. [Institute of Micro-system Physics, School of Physics and Electronics, Henan University, Kaifeng 475001 (China)], E-mail: wfzhang@henu.edu.cn

    2008-12-15

    Gd{sub 2}O{sub 3}:Sm{sup 3+} and Gd{sub 2}O{sub 3}:Sm{sup 3+},Bi{sup 3+} powders were prepared by a combustion method. Their structures were determined using X-ray diffraction. UV-visible absorption and photoluminescence spectra were investigated for Gd{sub 2}O{sub 3}:Sm{sup 3+} and Gd{sub 2}O{sub 3}:Sm{sup 3+},Bi{sup 3+} at different annealing temperatures and different doping concentrations. The emission spectra of all samples presented the characteristic emission narrow lines arising from the {sup 4}G{sub 5/2}{yields}{sup 6}H{sub J} transitions (J=5/2, 7/2, and 9/2) of Sm{sup 3+} ions upon excitation with UV irradiation. The emission intensity of Sm{sup 3+} ions was largely enhanced with introducing Bi{sup 3+} ions into Gd{sub 2}O{sub 3}:Sm{sup 3+} and the maximum occurred at a Bi{sup 3+} concentration of 0.5 mol%. The relevant mechanisms were discussed with the sensitization theory by Dexter and the aggregation behavior of Bi{sup 3+} ions.

  9. Imaging-based evaluation of liver function: comparison of {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy and Gd-EOB-DTPA-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Gebauer, Bernhard [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Luedemann, Lutz [Essen University Hospital, Department of Medical Physics, Essen (Germany); Froeling, Vera; Denecke, Timm [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany); Malinowski, Maciej; Stockmann, Martin; Baron, Annekathrin; Seehofer, Daniel [Charite Campus Virchow-Klinikum, Department of General, Visceral and Thoracic Surgery, Berlin (Germany); Prasad, Vikas [Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany)

    2015-05-01

    To compare Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests for separate evaluation of right (RLL) and left liver lobe (LLL) function. Fourteen patients underwent Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS after portal vein embolization within 24 h. Relative enhancement (RE) and hepatic uptake index (HUI) were determined from MRI; and T{sub max}, T{sub 1/2} and mebrofenin uptake were determined from HBS, all values separately for RLL and LLL. Mebrofenin uptake correlated significantly with HUI and RE for both liver lobes. There was strong correlation of mebrofenin uptake with HUI for RLL (r{sup 2} = 0.802, p = 0.001) and RE for LLL (r{sup 2} = 0.704, p = 0.005) and moderate correlation with HUI for LLL (r{sup 2} = 0.560, p = 0.037) and RE for RLL (r{sup 2} = 0.620, p = 0.018). Correlating the percentage share of RLL function derived from MRI (with HUI) with the percentage of RLL function derived from mebrofenin uptake revealed a strong correlation (r{sup 2} = 0.775, p = 0.002). Both RE and HUI correlate with mebrofenin uptake in HBS. The results suggest that Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS may equally be used to separately determine right and left liver lobe function. (orig.)

  10. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  11. Ferrimagnetic properties of Co/(Gd-Co) multilayers

    International Nuclear Information System (INIS)

    Svalov, A.V.; Fernandez, A.; Vas'kovskiy, V.O.; Tejedor, M.; Barandiaran, J.M.; Orue, I.; Kurlyandskaya, G.V.

    2006-01-01

    Co/(Gd-Co) multilayers have been prepared by rf-sputtering and investigated by means of Transverse Magnetooptic Kerr Effect (TMOKE), SQUID and VSM magnetometry. The composition of amorphous Gd 0.36 Co 0.64 layers was chosen so that their saturation magnetization was dominated by Gd moments in all the temperature range. Co and Gd-Co layers formed a macroscopic ferrimagnetically coupled system displaying a compensation temperature. Complete magnetic moment compensation was found at such point. An inversion of TMOKE hysteresis loops and a divergent behaviour of coercivity were also observed. By changing the layers thickness it has been possible to control the magnetic characteristics of the Co/(Gd-Co) structures, in particular the compensation takes place at different temperatures

  12. Pressure-enhanced light emission and its structural origin in Er:GdVO 4

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Fang; Yue, Binbin; Cheng, Zhenxiang; Shen, Hui; Yang, Ke; Hong, Xinguo; Chen, Bin; Mao, Ho-Kwang

    2017-01-09

    Rare earth phosphors have been widely studied because of their sharp emission lines and excellent optical performance. However, photoluminescence (PL) tuning by crystal field in Er3+ embedded phosphors has always been a challenge. Here, we demonstrate that pressure can help to enhance the red and green light emission simultaneously in Er:GdVO4. Synchrotron X-ray diffraction investigations revealed that a structural phase transition was responsible for the enhancement. Our work brightens the future prospects for applications of Er3+-based PL materials in various fields, such as high power lasers and (bio) medical imaging.

  13. Effect of Gd substitution on structure and spectroscopic properties of (Lu,Gd)2O3:Eu ceramic scintillator

    Science.gov (United States)

    Cao, Maoqing; Hu, Zewang; Ivanov, Maxim; Dai, Jiawei; Li, Chaoyu; Kou, Huamin; Shi, Yun; Chen, Haohong; Xu, Jiayue; Pan, Yubai; Li, Jiang

    2018-02-01

    In this paper, (Lu1-xGdx)2O3:Eu (x = 0, 0.1, 0.3, 0.5, 0.7, 0.9) ceramics were consolidated by the solid-state reaction method combined with vacuum sintering without sintering aids. We investigated the effect of the varying contents of Gd2O3 on the structure and spectroscopic properties of (Lu1-xGdx)2O3:Eu ceramics. X-ray diffraction (XRD) patterns indicate that proper amount of Gd2O3 can incorporate well with Lu2O3 and form Lu2O3-Gd2O3 solid solution. However, excessive Gd3+-doping in Lu2O3 will lead to the cubic phase transforming into monoclinic even hexagonal phase. The Gd3+ substitution no more than 50% of Lu2O3 enhances the radioluminescence, and reduces the fluorescence lifetime. Transmittance, photoluminescence, and radiation damage of the (Lu1-xGdx)2O3:Eu scintillation ceramics were also studied.

  14. Early versus late GD-DTPA MRI enhancement in experimental glioblastomas.

    Science.gov (United States)

    Farace, Paolo; Tambalo, Stefano; Fiorini, Silvia; Merigo, Flavia; Daducci, Alessandro; Nicolato, Elena; Conti, Giamaica; Degrassi, Anna; Sbarbati, Andrea; Marzola, Pasquina

    2011-03-01

    To compare early versus late enhancement in two glioblastoma models characterized by different infiltrative/edematous patterns. Three weeks after inoculation into nude mice of U87MG and U251 cells, T1-weighted images were acquired early (10.5 min), intermediate (21 min) and late (30.5 min) after a bolus injection of Gd-DTPA at 300 μ mol/kg dosage. EARLY(TH) and LATE(TH) were the corresponding volumes with an enhancement higher than a threshold TH, defined by the mean (μ) and standard deviation (σ) on a contralateral healthy area. ADD(TH) was the enhancing volume found in LATE(TH) but not in EARLY(TH). T2 imaging of both tumors was performed, and T2 mapping of U251. In all tumors, LATE(TH) was significantly higher than EARLY(TH) for TH ranging from μ+σ to μ+5σ. The ADD(TH) /EARLY(TH) ratio was not significantly different when U251 and U87MG tumors were compared. In the U87MG tumors, some enhancement was observed outside the regularly demarcated T2-hyperintense area. In the U251 tumors, irregularly T2 demarcated, a large portion of ADD(μ+3σ) had normal T2 values. At histology, U251 showed a higher infiltrative pattern than U87MG. In these models, the increase over time in the enhancing volume did not depend on the different infiltrative/edematous patterns and was not closely related with edema. Copyright © 2011 Wiley-Liss, Inc.

  15. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Yao, Y; Xiong, X; Lei, C; Soloveichik, S; Galstyan, E; Majkic, G

    2013-01-21

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12 mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  16. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    International Nuclear Information System (INIS)

    Selvamanickam, V; Shi, T; Liu, Y; Khatri, N D; Liu, J; Yao, Y; Galstyan, E; Majkic, G; Chen, Y; Xiong, X; Lei, C; Soloveichik, S

    2013-01-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba 2 Cu 3 O x film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm −2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m −3 . The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met. (paper)

  17. Hydrochlorothiazide-induced 131I excretion facilitated by salt and water

    International Nuclear Information System (INIS)

    Beyer, K.H. Jr.; Fehr, D.M.; Gelarden, R.T.; White, W.J.; Lang, C.M.; Vesell, E.S.

    1981-01-01

    Salt intake is restricted under clinical conditions for which thiazide diuretics are customarily used. Dietary iodide intake offsets any effect of thiazide on iodide loss. However, our correlation coefficients relating Na+ to Cl- to I- excretion indicate that as thiazide administration or sodium chloride intake increases renal Na+ and Cl- excretion, I- reabsorption by the nephron coordinately decreases. Increased sodium chloride and water intake by the dog doubled I-excretion rates. Hydrochlorothiazide increased the sodium chloride and water enhanced I-excretion rate as much as eight-fold. Without added NaCl, hydrochlorothiazide increased the excretion rate of 131I by three- to eightfold, acutely. Within five to seven days after 131I oral administration, hydrochlorothiazide (1 or 2 mg/kg twice daily) doubled the rate of 131I disappearance from plasma, reduced the fecal output of 131I, and increased its rate of renal excretion. When hydrochlorothiazide was administered, as much 131I was excreted in the first 24 hours as occurred in 48 hours when sodium chloride and water were given without hydrochlorothiazide. Thiazide administration in customary clinical dosage twice a day with substantial sodium chloride and water for the first two days after exposure to 131I, should therefore facilitate the safe excretion of 131I. This accelerated removal of 131I might be enhanced even more if thyroid uptake of 131I is blocked by administration of potassium iodide, as judged by the greater 131I recovery from thyroidectomized dogs

  18. Evaluation of renal transplants with Gd-DOTA dynamic MR imaging with factor analysis

    International Nuclear Information System (INIS)

    Chabrials, J.; Frouin, F.; Helenon, O.; Benall, H.; Kreis, H.; Moreau, J.F.; Di Paola, R.

    1990-01-01

    This paper reports on renal and urinary excretion factors by means of Gd-DOTA dynamic MR imaging and using factor analysis of dynamic structure (FADS) to follow-up renal transplants. We examined 60 patients with renal transplants by use of dynamic MR imaging after administration of a Gd-DOTA bolus (0.2 ml/kg) on a 0.5-T system; 10--12 fast gradient-echo sequences (TR/TE = 40/14, flip angle = 45 degree, acquisition time = 13 seconds) with single images and a 32-second intersequence delay were used. Of these, 13 dynamic MR imaging sequences were processed with an extension to dynamic MR images of FADS, previously developed to analyze nuclear medicine dynamic studies. The results were compared with the results of biologic dosages, renal biopsy and Seldinger digital arteriography

  19. Magnetism at the V/Gd interface

    International Nuclear Information System (INIS)

    Mouketo, L; M'Passi-Mabiala, B; Binggeli, N

    2010-01-01

    Recent experimental investigations into the magnetic properties of V/Gd bilayers have shown that vanadium, which is nonmagnetic in the bulk, can acquire a magnetic moment in such systems. We have performed ab initio pseudopotential calculations to examine the magnetic behavior of V(110)/Gd(0001) bilayers for V layers with thicknesses up to 4 monolayers (ML). We considered both abrupt and atomic intermixed V/Gd interfaces. In both cases, the magnetic moment of the V layer is found to align antiparallel to the moment of the Gd layer, consistent with the experimental observation. However, the magnitude of the V moment at the abrupt interface is considerably smaller than the moments reported experimentally. In the presence of atomic intermixing, instead, substantially larger V moments are found, closer to the experimentally reported moments. On the basis of the calculated atomic and spin resolved density of states, we discuss the possible mechanism responsible for the observed Gd-V antiferromagnetic coupling.

  20. Brain metastasis of small cell lung carcinoma. Comparison of Gd-DTPA enhanced magnetic resonance imaging and enhanced computerized tomography

    International Nuclear Information System (INIS)

    Nomoto, Yasushi; Yamaguchi, Yutaka; Miyamoto, Tadaaki.

    1994-01-01

    Small cell carcinoma of the lung (SCLC) frequently metastasizes into the brain, resulting in serious influences upon prognosis. Delayed brain damage caused by prophylactic cranial irradiation (PCI) is also problematic. Gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) enhanced magnetic resonance imaging (MRI) was performed to detect early brain metastasis from SCLC, and its usefulness was compared with contrast computerized tomography (CT). Among 25 SCLC patients, brain metastasis was detected in 11 by MRI and in 10 by CT, although six of them were completely asymptomatic. In the 11 patients, 6.3 and 2.4 lesions were respectively detected on average by MRI and CT. The ability of MRI to detect metastatic lesions of ≥15 mm diameter did not differ from that of CT, but became different as lesions became smaller (P<0.002), and MRI had a decided advantage over CT because as many as 30 lesions of ≤5 mm diameter were detected by MRI, whereas such lesions visualized on CT numbered only one (P<0.0001). MRI was incomparably superior to CT (P<0.0004) for subtentorial lesions since 18 lesions were detected on MRI, but only three, measuring ≥25 mm in diameter, were demonstrated on CT. Gd-DTPA enhanced MRI was determined to be extremely useful in the early diagnosis of SCLC brain metastasis. MRI was thought to reduce delayed brain damage caused by PCI if performed according to an adequate schedule. (author)

  1. MR imaging of prostatic neoplasms with and without Gd-DTPA as intravenous contrast agent

    International Nuclear Information System (INIS)

    Schmidt, H.; Beer, M.; Schnabl, G.; Hahn, D.; Naegele, M.

    1986-01-01

    Nine patients with prostatic carcinoma (proved by radical prostatectomy in five and by TUR in four), five patients with benign prostatic hyperplasia (BPH, proved by adenomectomy in two and by TUR in three) and three control subjects underwent MR imaging performed using the Siemens Magnetom (1.0T) and the spin echo sequences 1.6/30,90,0.5/30, and 0.2/20 msec prior to, and the sequences 0.5/30 and 0.2/20 after, administration of Gd-DTPA (0.2 mmol/kg). The normal prostate showed a low, homogeneous signal enhancement. In BPH, the signal enhancement of the adenoma varied widely. In three of the five patients the adenoma was better demarcated from the pseudocapsule after administration of Gd-DTPA than on the precontrast image. The prostatic carcinoma showed only slightly less signal enhancement than BPH. On the postcontrast image, six of the nine carcinomas were visualized as a hyperintense nodule. However, reliable differentiation of prostatic carcinoma from BPH by means of signal enhancement was not possible

  2. Pharmacokinetic analysis of Gd-DTPA enhancement in dynamic MR of breast carcinoma. Pharmakokinetische Analyse der Gd-DTPA-Anreicherung in der MRT beim Mammakarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Hess, T. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Knopp, M.V. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Hoffmann, U. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Brix, G. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Junkermann, H. (Heidelberg Univ. (Germany). Abteilung fuer Gynaekologische Radiologie); Zuna, I. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Fournier, D. von (Heidelberg Univ. (Germany). Abteilung fuer Gynaekologische Radiologie); Kaick, G. van (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie)

    1994-06-01

    Dynamic Gd-DTPA enhanced MR of the breast was performed in one single slice in 27 patients with suspicious nodular lesions. The results could be histologically verified in all cases. A rapid spin-echo sequence with a time resolution of 8.75 s was used for the dynamic examination. The signal changes were analysed using a pharmacokinetic model which allowed parametrization of the contrast enhancement and transformation of the data into colour coded parameter images. The parameters allowed reliable distinction of 9 benign from 18 malignant lesions (p<0.05 for ''amplitude'', p<0.001 for ''k[sub 21]''). One fibroadenoma could not be distinguished from the carcinomas. Lymph node metastases and the pharmacokinetic parameter amplitude correlated significantly (p<0.05). (orig.)

  3. Ways for accurate analysis of high purity materials using the glow discharge mass spectrometry (GD-MS); Wege zur genauen Charakterisierung hochreiner Materialien mit der Glimmentladungs-Massenspektrometrie (GD-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Gusarova, Tamara

    2010-04-14

    The main aim of this work consists in the investigation, development and application of improved possibilities of accurate analysis of high purity materials using the solid sample technique of Glow Discharge Mass Spectrometry (GD-MS), as well as in the sensitivity enhancement of GD Optical Emission Spectrometry (GD-OES) by implicating the hollow cathode effect. The emphasis of the PhD thesis consists in the accurate quantification for GD-MS. As appropriate certified reference materials (CRMs) for calibration are lacking in most cases an accurate quantification especially for trace elements mass fractions at {mu}g kg{sup -1} level can often not be achieved. To overcome this problem and to expand the possibilities of modern GD-MS hereby, synthetic standards were applied for calibration of both high resolution GD-MS instruments ''VG 9000'' and ''Element GD''. The standards were prepared by doping of matrix powder with trace element standard solutions followed by drying and pressing the doped powder to compact pellets. With the quantification approach worked out and described here accurate analysis results with small uncertainties can be achieved for most elements of periodic table in almost every matrix composition. Furthermore direct traceability of the analytical results to the International System of Units (SI) is provided ensuring their higher metrological quality. Numerous additional systematic investigations concerning the preparation of the synthetic standards and their properties were carried out. The results of calibration of GD-MS instruments with synthetic standards for Co (Co-C), Cu, In, Fe and Zn matrices were checked by measuring CRMs. These results were also contrasted with those of other quantification approaches, as usually used in GD-MS routine. The results achieved with synthetic standards had the highest accuracy. The successful participation in the round robin test CCQM-P107 between international

  4. Enhanced refrigerant capacity in Gd-Al-Co microwires with a biphase nanocrystalline/amorphous structure

    Energy Technology Data Exchange (ETDEWEB)

    Shen, H. X. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Department of Physics, University of South Florida, Tampa, Florida 33620 (United States); Xing, D. W.; Liu, Y. F.; Sun, J. F. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China); Sánchez Llamazares, J. L. [Instituto Potosino de Investigación Científica y Tecnológica A.C., Camino a la Presa San José 2055 Col. Lomas 4a, San Luis Potosí, S.L.P. 78216 (Mexico); Sánchez-Valdés, C. F. [Centro de Nanociencias y Nanotecnología, Universidad Nacional Autónoma de México, AP 14, Ensenada 22860, Baja California (Mexico); Belliveau, H.; Srikanth, H.; Phan, M. H., E-mail: phanm@usf.edu [Department of Physics, University of South Florida, Tampa, Florida 33620 (United States); Wang, H.; Qin, F. X. [Institute for Composites Science and Innovation (InCSI), College of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2016-02-29

    A class of biphase nanocrystalline/amorphous Gd{sub (50+5x)}Al{sub (30−5x)}Co{sub 20} (x = 0, 1, 2) microwires fabricated directly by melt-extraction is reported. High resolution transmission electron microscopy and Fourier function transform based analysis indicate the presence of a volume fraction (∼20%) of ∼10 nm sized nanocrystallities uniformly embedded in an amorphous matrix. The microwires possess excellent magnetocaloric properties, with large values of the isothermal entropy change (−ΔS{sub M} ∼ 9.7 J kg{sup −1} K{sup −1}), the adiabatic temperature change (ΔT{sub ad} ∼ 5.2 K), and the refrigerant capacity (RC ∼ 654 J kg{sup −1}) for a field change of 5 T. The addition of Gd significantly alters T{sub C} while preserving large values of the ΔS{sub M} and RC. The nanocrystallites allow for enhanced RC as well as a broader operating temperature span of a magnetic bed for energy-efficient magnetic refrigeration.

  5. Volume Change and Liver Parenchymal Signal Intensity in Gd-EOB-DTPA-Enhanced Magnetic Resonance Imaging after Portal Vein Embolization prior to Hepatectomy

    Directory of Open Access Journals (Sweden)

    Ayako Akiba

    2014-01-01

    Full Text Available Purpose. To investigate the liver volume change and the potential of early evaluation by contrast-enhanced magnetic resonance imaging (MRI using gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA after portal vein embolization (PVE. Materials and Methods. Retrospective evaluations of computed tomography (CT volumetry of total liver and nonembolized areas were performed before and 3 weeks after PVE in 37 cases. The percentage of future liver remnant (%FLR and the change ratio of %FLR (%FLR ratio were calculated. Prospective evaluation of signal intensities (SIs was performed to estimate the role of Gd-EOB-DTPA-enhanced MRI as a predictor of hypertrophy in 16 cases. The SI contrast between embolized and nonembolized areas was calculated 1 week after PVE. The change in SI contrast before and after PVE (SI ratio was also calculated in 11 cases. Results. %FLR ratio significantly increased, and SI ratio significantly decreased (both P<0.01. There were significant negative correlations between %FLR and SI contrast and between %FLR and SI ratio (both P<0.01. Conclusion. Hypertrophy in the nonembolized area after PVE was indicated by CT volumetry, and measurement of SI contrast and SI ratio in Gd-EOB-DTPA-enhanced MRI early after PVE may be useful to predict the potential for hepatic hypertrophy.

  6. MRI enhancement of the facial nerve with Gd-DTPA, 2; Investigation of enhanced nerve portions in patients with facial palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Masahiro [Kansai Medical School, Moriguchi, Osaka (Japan)

    1993-08-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author).

  7. Test of E1-radiative strength function and level density models by 155 Gd (n,2γ) 156 Gd reaction

    International Nuclear Information System (INIS)

    Voinov, A.V.

    1996-01-01

    The information about the level density of 156 Gd nucleus and strength functions of γ transitions extracted from two γ-cascade spectra of the 155 Gd (n,2γ) 156 Gd reaction is analyzed. The method of statistical simulation of γ-cascade intensity is applied for calculation of the main parameters of experimental spectra. The method is used to extract the information on the E1-radiative strength function of γ transitions and level density in the 156 Gd nucleus. It is shown that at an excitation energy above 3 MeV the level density of 156 Gd nucleus must decrease in comparison with that calculated within the Fermi gas model. Its is concluded that possible explanation of the observed effect is connected with the influence of pairing correlations on the level density in nuclei

  8. Magnetic nanoparticles induced dielectric enhancement in (La, Gd)2O3: SiO2 composite systems

    Science.gov (United States)

    Kao, T. H.; Mukherjee, S.; Yang, H. D.

    2013-11-01

    Magnetic Gd2O3 and non-magnetic La2O3 nanoparticles (NPs) have been synthesized together with different doping concentrations in SiO2 matrix via sol-gel route calcination at 700 °C and above. Properly annealed NP-glass composite systems show enhancement of dielectric constant and magnetodielectric effect (MDE) near room temperature, depending on superparamagnetic NPs concentrations. From application point of view, the enhancement of dielectric constant along with MDE can be achieved by tuning the NPs size through varying calcination temperature and/or increasing the doping concentration of magnetic rare earth oxide.

  9. Multiple FNH-Like Lesions in a Patient with Chronic Budd-Chiari Syndrome: Gd-EOB-Enhanced MRI and BR1 CEUS Findings

    Directory of Open Access Journals (Sweden)

    Caroline Newerla

    2012-01-01

    Full Text Available A-26-year old female patient with chronic Budd-Chiari syndrome due to different underlying blood disorders applied for a two-year followup of the liver with Gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic-acid-(Gd-EOB-DTPA- enhanced MRI. The liver function tests were raised. Besides showing a progressive hepatosplenomegaly and a cirrhotic liver alteration, the MRI revealed multiple new nodular lesions in all liver segments. These lesions showed typical patterns in the precontrast images, while there was an arterial and a persistent portal venous enhancement. In the hepatobiliary liver-specific late phase, a central “washout” and a persistent rim enhancement were observed (target sign. The additionally performed contrast-enhanced ultrasonography showed a strong zentrifugal arterial enhancement of the lesions followed by an isoechoic enhancement in the portal venous and delayed liver phase. Histologically these lesions turned out as focal nodular hyperplasias (FNH or FNH-like lesions, also known as large regenerative nodules (LRNs. Differentiation between regenerative nodules like LRN and hepatocellular carcinoma (HCC in cirrhotic livers is crucial, and the target sign in the hepatobiliary phase of Gd-EOB-DTPA as well as the centrifugal arterial enhancement followed by an isoenhancement during a CEUS might be useful for establishing the correct diagnosis of such hypervascular lesions with proliferated and likely aberrant bile ducts.

  10. Pr and Gd co-doped bismuth ferrite thin films with enhanced

    Indian Academy of Sciences (India)

    Pr and Gd co-modified Bi0.95−PrGd0.05FeO3 ( = 0.00, 0.05, 0.10) (BPGFO) thin films on Pt(111)/Ti/SiO2/Si(100) substrates were prepared by a sol-gel together with spin coating technique. A detailed study of electrical and magnetic properties of these thin films is reported. X-ray diffraction analysis shows that, with an ...

  11. Gd-DTPA T1 relaxivity in brain tissue obtained by convection-enhanced delivery, magnetic resonance imaging and emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Haar, Peter J [Department of Anatomy and Neurobiology, Virginia Commonwealth University, Richmond, VA (United States); Broaddus, William C; Chen Zhijian; Gillies, George T [Department of Neurosurgery, Virginia Commonwealth University, Richmond, VA (United States); Fatouros, Panos P; Corwin, Frank D, E-mail: wbroaddus@mcvh-vcu.ed [Department of Radiology, Virginia Commonwealth University, Richmond, VA (United States)

    2010-06-21

    A common approach to quantify gadolinium (Gd) contrast agents involves measuring the post-contrast change in T1 rate and then using the constant T1 relaxivity R to determine the contrast agent concentration. Because this method is fast and non-invasive, it could be potentially valuable in many areas of brain research. However, to accurately measure contrast agent concentrations in the brain, the T1 relaxivity R of the specific agent must be accurately known. Furthermore, the macromolecular content and compartmentalization of the brain extracellular space (ECS) are expected to significantly alter R from values measured in aqueous solutions. In this study, the T1 relaxivity R of gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) was measured following direct interstitial infusions of three different contrast agent concentrations to the parenchyma of rat brains. Changes in magnetic resonance (MR) T1 values were compared to brain slice concentrations determined with inductively coupled plasma atomic emission spectroscopy (ICP-AES) to determine R in 15 rats. Additionally, samples of cerebrospinal fluid, blood and urine were analyzed to evaluate possible Gd-DTPA clearance from the brain. The T1 relaxivity R of Gd-DTPA in the brain ECS was measured to be 5.35 (mM s){sup -1} in a 2.4 T field. This value is considerably higher than estimations used in studies by other groups. Measurements of brain Gd-DTPA tissue concentrations using MRI and ICP-AES demonstrated a high degree of coincidence. Clearance of Gd-DTPA was minimal at the time point immediately after infusion. These results suggest that the environment of the brain does in fact significantly affect Gd T1 relaxivity, and that MRI can accurately measure contrast agent concentrations when this relaxivity is well characterized.

  12. Gd-DTPA T1 relaxivity in brain tissue obtained by convection-enhanced delivery, magnetic resonance imaging and emission spectroscopy

    Science.gov (United States)

    Haar, Peter J.; Broaddus, William C.; Chen, Zhi-jian; Fatouros, Panos P.; Gillies, George T.; Corwin, Frank D.

    2010-06-01

    A common approach to quantify gadolinium (Gd) contrast agents involves measuring the post-contrast change in T1 rate and then using the constant T1 relaxivity R to determine the contrast agent concentration. Because this method is fast and non-invasive, it could be potentially valuable in many areas of brain research. However, to accurately measure contrast agent concentrations in the brain, the T1 relaxivity R of the specific agent must be accurately known. Furthermore, the macromolecular content and compartmentalization of the brain extracellular space (ECS) are expected to significantly alter R from values measured in aqueous solutions. In this study, the T1 relaxivity R of gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) was measured following direct interstitial infusions of three different contrast agent concentrations to the parenchyma of rat brains. Changes in magnetic resonance (MR) T1 values were compared to brain slice concentrations determined with inductively coupled plasma atomic emission spectroscopy (ICP-AES) to determine R in 15 rats. Additionally, samples of cerebrospinal fluid, blood and urine were analyzed to evaluate possible Gd-DTPA clearance from the brain. The T1 relaxivity R of Gd-DTPA in the brain ECS was measured to be 5.35 (mM s)-1 in a 2.4 T field. This value is considerably higher than estimations used in studies by other groups. Measurements of brain Gd-DTPA tissue concentrations using MRI and ICP-AES demonstrated a high degree of coincidence. Clearance of Gd-DTPA was minimal at the time point immediately after infusion. These results suggest that the environment of the brain does in fact significantly affect Gd T1 relaxivity, and that MRI can accurately measure contrast agent concentrations when this relaxivity is well characterized.

  13. Gd-DTPA T1 relaxivity in brain tissue obtained by convection-enhanced delivery, magnetic resonance imaging and emission spectroscopy

    International Nuclear Information System (INIS)

    Haar, Peter J; Broaddus, William C; Chen Zhijian; Gillies, George T; Fatouros, Panos P; Corwin, Frank D

    2010-01-01

    A common approach to quantify gadolinium (Gd) contrast agents involves measuring the post-contrast change in T1 rate and then using the constant T1 relaxivity R to determine the contrast agent concentration. Because this method is fast and non-invasive, it could be potentially valuable in many areas of brain research. However, to accurately measure contrast agent concentrations in the brain, the T1 relaxivity R of the specific agent must be accurately known. Furthermore, the macromolecular content and compartmentalization of the brain extracellular space (ECS) are expected to significantly alter R from values measured in aqueous solutions. In this study, the T1 relaxivity R of gadolinium-diethylene-triamine penta-acetic acid (Gd-DTPA) was measured following direct interstitial infusions of three different contrast agent concentrations to the parenchyma of rat brains. Changes in magnetic resonance (MR) T1 values were compared to brain slice concentrations determined with inductively coupled plasma atomic emission spectroscopy (ICP-AES) to determine R in 15 rats. Additionally, samples of cerebrospinal fluid, blood and urine were analyzed to evaluate possible Gd-DTPA clearance from the brain. The T1 relaxivity R of Gd-DTPA in the brain ECS was measured to be 5.35 (mM s) -1 in a 2.4 T field. This value is considerably higher than estimations used in studies by other groups. Measurements of brain Gd-DTPA tissue concentrations using MRI and ICP-AES demonstrated a high degree of coincidence. Clearance of Gd-DTPA was minimal at the time point immediately after infusion. These results suggest that the environment of the brain does in fact significantly affect Gd T1 relaxivity, and that MRI can accurately measure contrast agent concentrations when this relaxivity is well characterized.

  14. An experimental study on renal functional disturbance in rabbits after acute ureteral obstruction with dynamic Gd-DTPA enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyoung Ja [Seoul Red Cross Hospital, Seoul (Korea, Republic of); Chung, Eun Chul; Rlee, Chung Sik [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1994-05-15

    To evaluate the anatomic and functional change in acutely obstructed kidneys, and probability of functional recovery after resolving the obstruction. There were 5 animal groups (6 rabbits in each group)-normal control group, 4 acute ureteral obstruction group. Each of the latter group was imaged with Gd-DTPA enhanced dynamic MR 2, 6, 24, and 48 hours after ligation of the left proximal urter, respectively. We compared the findings of dynamic MR imaging and histopathological findings. We could observe centripetal movement of dark band pattern which could be defined as 3 phases renal cortex, outer medulla, and inner medulla in normal rabbits. The appearance of the dark band pattern was delayed or absent in ureteral obstruction group with linear relationship to the duration of the obstruction. Gd-DTPA enhanced MR can be used to differentiate acute obstructive nephropathy from other causes of nephropathy and foretell the prognosis of the obstruction.

  15. An experimental study on renal functional disturbance in rabbits after acute ureteral obstruction with dynamic Gd-DTPA enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Kyoung Ja; Chung, Eun Chul; Rlee, Chung Sik

    1994-01-01

    To evaluate the anatomic and functional change in acutely obstructed kidneys, and probability of functional recovery after resolving the obstruction. There were 5 animal groups (6 rabbits in each group)-normal control group, 4 acute ureteral obstruction group. Each of the latter group was imaged with Gd-DTPA enhanced dynamic MR 2, 6, 24, and 48 hours after ligation of the left proximal urter, respectively. We compared the findings of dynamic MR imaging and histopathological findings. We could observe centripetal movement of dark band pattern which could be defined as 3 phases renal cortex, outer medulla, and inner medulla in normal rabbits. The appearance of the dark band pattern was delayed or absent in ureteral obstruction group with linear relationship to the duration of the obstruction. Gd-DTPA enhanced MR can be used to differentiate acute obstructive nephropathy from other causes of nephropathy and foretell the prognosis of the obstruction

  16. MRI enhancement of the facial nerve with Gd-DTPA, 2; Investigation of enhanced nerve portions in patients with facial palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Masahiro (Kansai Medical School, Moriguchi, Osaka (Japan))

    1993-08-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author).

  17. Gd-Ni-Si system

    International Nuclear Information System (INIS)

    Bodak, O.I.; Shvets, A.F.

    1983-01-01

    By X-ray phase analysis method isothermal cross section of phase diagram of the Gd-Ni-Si system at 870 K is studied. The existence of nine previously known compounds (GdNisub(6.72)Sisub(6.28), GdNi 10 Si 2 , GdNi 5 Si 3 , GdNi 4 Si, GdNi 2 Si 2 , GdNiSi 3 , GdNiSi 2 , Gd 3 Ni 6 Si 2 and GdNiSi) is confirmed and three new compounds (GdNisub(0.2)Sisub(1.8), Gdsub(2)Nisub(1-0.8)Sisub(1-1.2), Gd 5 NiSi 4 ) are found. On the base of Gd 2 Si 3 compound up to 0.15 at. Ni fractions, an interstitial solid solution is formed up to 0.25 at Ni fractions dissolution continues of substitution type. The Gd-Ni-Si system is similar to the Y-Ni-Si system

  18. Enhancing contrast of magnetic resonance imaging in patients with ...

    African Journals Online (AJOL)

    11031, Taiwan, 2Institute of Biological Chemistry, Academia Sinica, 128 Academia Road, Section 2 ... Purpose: To determine transit times for excretion of gadoxetic acid (Gd-EOB-DTPA), a recent magnetic .... evaluated by the same radiologist.

  19. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver: The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient (ADC)

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Podgórska, Joanna; Rosiak, Grzegorz; Maj, Edyta; Grudziński, Ireneusz P.; Kaczyński, Bartosz; Szeszkowski, Wojciech; Milczarek, Krzysztof; Rowiński, Olgierd

    2016-01-01

    To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving

  20. Gd3+-ESR and magnetic susceptibility of GdCu4Al8 and GdMn4Al8

    International Nuclear Information System (INIS)

    Coldea, R.; Coldea, M.; Pop, I.

    1994-01-01

    Gd ESR of GdCu 4 Al 8 and GdMn 4 Al 8 and magnetic susceptibility of GdCu 4 Al 8 , GdMn 4 Al 8 , and YMn 4 Al 8 were measured in the temperature range of 290K--460K and 90K--1050K, respectively. The occurrence of the Mn moment in YMn 4 Al 8 and GdMn 4 Al 8 is strongly correlated with the critical value of d∼2.6 angstrom of the Mn-Mn distance below which the Mn moment is not stable. The experimental data for GdMn 4 Al 8 , compared with the data for the isostructural compounds GdCu 4 Al 8 and YMn 4 Al 8 , show that near the critical value of d, the existence of Mn moment depends not only on the value of d, but also on the local magnetic surroundings. It has been revealed that the magnetic character of Mn moment in YMn 4 Al 8 and GdMn 4 Al 8 changes from an itinerant electron type to a local-moment type with increasing temperature

  1. Magnetic upconverting fluorescent NaGdF4:Ln3+ and iron-oxide@NaGdF4:Ln3+ nanoparticles

    Science.gov (United States)

    Shrivastava, Navadeep; Rocha, Uéslen; Muraca, Diego; Jacinto, Carlos; Moreno, Sergio; Vargas, J. M.; Sharma, S. K.

    2018-05-01

    Microwave assisted solvothermal method has been employed to synthesize multifunctional upconverting β-NaGdF4:Ln3+ and magnetic-upconverting Fe3O4/γ-Fe2O3@NaGdF4:Ln3+ (Ln = Yb and Er) nanoparticles. The powder x-ray diffraction data confirms the hexagonal structure of NaGdF4:Ln3+ and high resolution transmission electron microscopy shows the formation of rod shaped NaGdF4:Ln3+ (˜ 20 nm) and ovoid shaped Fe3O4/γ-Fe2O3@NaGdF4:Ln3+ (˜ 15 nm) nanoparticles. The magnetic hysteresis at 300 K for β-NaGdF4:Ln3+ demonstrates paramagnetic features, whereas iron-oxide@β-NaGdF4:Ln3+ exhibits superparamagnetic behavior along with a linear component at large applied field due to paramagnetic NaGdF4 matrix. Both nanoparticle samples provide an excellent green emitting [(2H11/2, 4S3/2)→4I15/2 (˜ 540 nm)] upconversion luminescence emission under excitation at 980 nm. The energy migration between Yb and Er in NaGdF4 matrix has been explored from 300-800 nm. Intensity variation of blue, green and red lines and the observed luminescence quenching due to the presence of Fe3O4/γ-Fe2O3 in the composite has been proposed. These kinds of materials contain magnetic and luminescence characteristics into single nanoparticle open new possibility for bioimaging applications.

  2. Obtaining strong ferromagnetism in diluted Gd-doped ZnO thin films through controlled Gd-defect complexes

    KAUST Repository

    Roqan, Iman S.

    2015-02-21

    We demonstrate the fabrication of reproducible long-range ferromagnetism (FM) in highly crystalline GdxZn1-xO thin films by controlling the defects. Films are grown on lattice-matched substrates by pulsed laser deposition at low oxygen pressures (≤25 mTorr) and low Gd concentrations (x ≤ 0.009). These films feature strong FM (10 μB per Gd atom) at room temperature. While films deposited at higher oxygen pressure do not exhibit FM, FM is recovered by post-annealing these films under vacuum. These findings reveal the contribution of oxygen deficiency defects to the long-range FM. We demonstrate the possible FM mechanisms, which are confirmed by density functional theory study, and show that Gd dopants are essential for establishing FM that is induced by intrinsic defects in these films.

  3. Obtaining strong ferromagnetism in diluted Gd-doped ZnO thin films through controlled Gd-defect complexes

    KAUST Repository

    Roqan, Iman S.; Venkatesh, S.; Zhang, Z.; Hussain, S.; Bantounas, Ioannis; Franklin, J. B.; Flemban, Tahani H.; Zou, B.; Lee, J.-S.; Schwingenschlö gl, Udo; Petrov, P. K.; Ryan, M. P.; Alford, N. M.

    2015-01-01

    We demonstrate the fabrication of reproducible long-range ferromagnetism (FM) in highly crystalline GdxZn1-xO thin films by controlling the defects. Films are grown on lattice-matched substrates by pulsed laser deposition at low oxygen pressures (≤25 mTorr) and low Gd concentrations (x ≤ 0.009). These films feature strong FM (10 μB per Gd atom) at room temperature. While films deposited at higher oxygen pressure do not exhibit FM, FM is recovered by post-annealing these films under vacuum. These findings reveal the contribution of oxygen deficiency defects to the long-range FM. We demonstrate the possible FM mechanisms, which are confirmed by density functional theory study, and show that Gd dopants are essential for establishing FM that is induced by intrinsic defects in these films.

  4. Magnetic and transport properties of amorphous ferro magnetic Gd--Au, Gd--Ni and Gd--Co alloys obtained by splat-cooling

    International Nuclear Information System (INIS)

    Durand, J.; Poon, S.J.

    1977-06-01

    We present the results of magnetization and transport measurements on the amorphous Gd 80 Au 20 , Gd 68 Ni 32 and Gd 67 Co 33 alloys over a temperature range of 1.8 to 300 0 K in fields up to 75 kOe. These ferromagnetic alloys obtained by splat-cooling have Curie temperatures T/sub c/ of 150, 125 and 175 0 K, respectively. The saturation moment per Gd atom extrapolated to 0 0 K is estimated to be 7 +- 0.1 μ/sub B/. The exchange integrals for Gd-Au and Gd-Ni are determined from the value of T/sub c/ and from the temperature dependence of the saturation magnetization. The zero-field resistivity for Gd-Ni and Gd-Co exhibits maxima around T/sub c/. We present some preliminary results of magnetoresistivity measurements with applied field parallel and perpendicular to the foil plane. The anisotropy is in-plane for Gd-Co. For the Gd-Au and Gd-Ni alloys, there is no well-defined easy axis

  5. Expression of OATP1B3 determines uptake of Gd-EOB-DTPA in hepatocellular carcinoma

    OpenAIRE

    Narita, Masato; Hatano, Etsuro; Arizono, Shigeki; Miyagawa-Hayashino, Aya; Isoda, Hiroyoshi; Kitamura, Koji; Yasuchika, Kentaro; Nitta, Takashi; Uemoto, Shinji

    2009-01-01

    Background: Gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) is an MRI contrast agent with perfusion and hepatoselective properties. The purpose of the study was to examine uptake of Gd-EOB-DTPA in the hepatobiliary phase in hepatocellular carcinoma (HCC). Methods: A retrospective analysis of 22 patients with HCC who underwent preoperative Gd-EOB-DTPA-enhanced MRI was performed. Enhancement ratios (ERs) and expression levels of the organic anion transporter (OATP) 1B3...

  6. A test to enhance the excretion of tritium in man by excessive water intake

    International Nuclear Information System (INIS)

    Takada, K.; Fukuda, H.; Hattori, T.; Akaishi, J.

    1981-01-01

    A worker who accidentally inhaled tritium water vapour at a heavy-water-moderated reactor was recommended to drink an excessive amount of water to enhance the excretion of incorporated tritium. The change in biological half-life of tritium in the body was studied by measuring the tritium in urine, saliva and exhaled water. The results obtained in the present test showed that if the intake of excessive water is performed under no special control the expected shortening of tritium half-life is not necessarily achieved. When severe incorporation of tritium occurs, greater amounts of water than those in the present test must be taken. (U.K.)

  7. Gd2O3 nanoparticles in hematopoietic cells for MRI contrast enhancement

    Directory of Open Access Journals (Sweden)

    Hedlund A

    2011-12-01

    Full Text Available Anna Hedlund1,2, Maria Ahrén3, Håkan Gustafsson1,2, Natalia Abrikossova3, Marcel Warntjes2,4, Jan-Ingvar Jönsson5, Kajsa Uvdal3, Maria Engström1,21Division of Radiology, Department of Medical and Health Sciences, 2Center for Medical Image Science and Visualization, 3Division of Molecular Surface Physics and Nanoscience, Department of Physics, Chemistry, and Biology, 4Division of Clinical Physiology, Department of Medicine and Health Sciences, 5Department of Clinical and Experimental Medicine, Experimental Hematology Unit, Linköping University, Linköping, SwedenAbstract: As the utility of magnetic resonance imaging (MRI broadens, the importance of having specific and efficient contrast agents increases and in recent time there has been a huge development in the fields of molecular imaging and intracellular markers. Previous studies have shown that gadolinium oxide (Gd2O3 nanoparticles generate higher relaxivity than currently available Gd chelates: In addition, the Gd2O3 nanoparticles have promising properties for MRI cell tracking. The aim of the present work was to study cell labeling with Gd2O3 nanoparticles in hematopoietic cells and to improve techniques for monitoring hematopoietic stem cell migration by MRI. Particle uptake was studied in two cell lines: the hematopoietic progenitor cell line Ba/F3 and the monocytic cell line THP-1. Cells were incubated with Gd2O3 nanoparticles and it was investigated whether the transfection agent protamine sulfate increased the particle uptake. Treated cells were examined by electron microscopy and MRI, and analyzed for particle content by inductively coupled plasma sector field mass spectrometry. Results showed that particles were intracellular, however, sparsely in Ba/F3. The relaxation times were shortened with increasing particle concentration. Relaxivities, r1 and r2 at 1.5 T and 21°C, for Gd2O3 nanoparticles in different cell samples were 3.6–5.3 s-1 mM-1 and 9.6–17.2 s-1 mM-1

  8. Detection of hepatocellular carcinoma by Gd-EOB-DTPA-enhanced liver MRI: Comparison with triple phase 64 detector row helical CT

    International Nuclear Information System (INIS)

    Akai, Hiroyuki; Kiryu, Shigeru; Matsuda, Izuru; Satou, Jirou; Takao, Hidemasa; Tajima, Taku; Watanabe, Yasushi; Imamura, Hiroshi; Kokudo, Norihiro; Akahane, Masaaki; Ohtomo, Kuni

    2011-01-01

    Purpose: To compare the diagnostic performance of Gd-EOB-DTPA-enhanced MRI with that of triple phase 64-MDCT in the detection of hepatocellular carcinoma (HCC). Patients and methods: Thirty-four patients with 52 surgically proven lesions underwent Gd-EOB-DTPA-enhanced MRI and triple phase 64-MDCT. Two observers independently evaluated MR and CT imaging on a lesion-by-lesion basis. Sensitivity, positive and negative predictive values and reproducibility were evaluated. The diagnostic accuracy of each modality was assessed with alternative-free response receiver operating characteristic (ROC) analysis. Results: Both observers showed higher sensitivity in detecting lesions with MRI compared to CT, however, only the difference between the two imaging techniques for observer 2 was significant (P = 0.034). For lesions 1 cm or smaller, MRI and CT showed equal sensitivity (both 62.5%) with one observer, and MRI proved superior to CT with the other observer (MRI 75% vs. CT 56.3%), but the latter difference was not significant (P = 0.083). The difference in positive and negative predictive value between the two imaging techniques for each observer was not significant (P > 0.05). The areas under the ROC curve for each observer were 0.843 and 0.861 for MRI vs. 0.800 and 0.833 for CT and the differences were not significant. Reproducibility was higher using MRI for both observers, but the result was not significant (MRI 32/33 vs. CT 29/33, P = 0.083). Conclusion: Gd-EOB-DTPA-enhanced MRI tended to show higher diagnostic accuracy, sensitivity and reproducibility compared to triple phase 64-MDCT in the detection of hepatocellular carcinoma, however statistical significance was not achieved.

  9. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  10. The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides.

    Science.gov (United States)

    Cao, Limin; Li, Binbin; Yi, Peiwei; Zhang, Hailu; Dai, Jianwu; Tan, Bo; Deng, Zongwu

    2014-04-01

    Three Gd-DOTA-peptide complexes with different peptide sequence are synthesized and used as T1 contrast agent to label human mesenchymal stem cells (hMSCs) for magnetic resonance imaging study. The peptides include a universal cell penetrating peptide TAT, a linear MSC-specific peptide EM7, and a cyclic MSC-specific peptide CC9. A significant difference in labeling efficacy is observed between the Gd-DOTA-peptides as well as a control Dotarem. All Gd-DOTA-peptides as well as Dotarem induce significant increase in T1 relaxation rate which is in favor of T1-weighted MR imaging. Gd-DOTA-CC9 yields the maximum labeling efficacy but poor T1 contrast enhancement. Gd-DOTA-EM7 yields the minimum labeling efficacy but better T1 contrast enhancement. Gd-DOTA-TAT yields a similar labeling efficacy as Gd-DOTA-CC9 and similar T1 contrast enhancement as Gd-DOTA-EM7. The underlying mechanism that governs T1 contrast enhancement effect is discussed. Our results suggest that T1 contrast enhancement induced by Gd-DOTA-peptides depends not only on the introduced cellular Gd content, but more importantly on the effect that Gd-DOTA-peptides exert on the T1-relaxation and T2-relaxation processes/rates. Both T1 and particularly T2 relaxation rate have to be taken into account to interpret T1 contrast enhancement. In addition, the interpretation has to be based on cellular instead of aqueous longitudinal and transverse relaxivities of Gd-DOTA-peptides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. SIMS imaging of gadolinium isotopes in tissue from Nephrogenic Systemic Fibrosis patients: Release of free Gd from magnetic resonance imaging (MRI) contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, Jerrold L. [Department of Pathology, SUNY Upstate Medical University, Syracuse, New York (United States); Chandra, Subhash [Cornell SIMS Laboratory, Department of Earth and Atmospheric Sciences, Cornell University, Ithaca, NY 14853 (United States)], E-mail: sc40@cornell.edu; Thakral, Charu [Department of Pathology, SUNY Upstate Medical University, Syracuse, New York (United States); Abraham, Joshua M. [Cornell SIMS Laboratory, Department of Earth and Atmospheric Sciences, Cornell University, Ithaca, NY 14853 (United States)

    2008-12-15

    Recently, Gd-based magnetic resonance imaging (MRI) contrast agents (GBMCA) have been linked to a new disease, Nephrogenic Systemic Fibrosis (NSF), with skin and systemic toxicity and death in certain patients with renal failure. Due to widespread use of GBMCA in diagnostic MRI, it is essential to study their excretion, metabolism, and target sites in cells and tissues. A CAMECA IMS-3f SIMS ion microscope and scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) were used for imaging Gd isotopes in relation to calcium distributions in histologic sections of human tissues. SIMS imaging revealed two types of Gd localization in skin biopsies of patients who received GBMCA. The Gd was present in micrometer size deposits in association with calcium, and in detectable amounts in a more diffuse cellular distribution. Only the Gd-containing deposits associated with Ca and P were detectable using SEM/EDS. As only insoluble deposits remain in the biopsy tissues after aqueous and organic solvent processing of the tissue, our observations support release of free Gd from the GBMCA and selective localization of insoluble Gd in the target tissue from patients with NSF. This study opens new novel applications of SIMS for characterization of the safety of GBMCA.

  12. Room temperature magnetic ordering, enhanced magnetization and exchange bias of GdMnO_3 nanoparticles in (GdMnO_3)_0_._7_0(CoFe_2O_4)_0_._3_0

    International Nuclear Information System (INIS)

    Mitra, A.; Mahapatra, A.S.; Mallick, A.; Chakrabarti, P.K.

    2017-01-01

    Nanoparticles of GdMnO_3 (GMO) are prepared by sol-gel method. To enhance the magnetic property and also to obtain the magnetic ordering at room temperature (RT), nanoparticles of GMO are incorporated in the matrix of CoFe_2O_4 (CFO). Desired crystallographic phases of CFO, GMO and GMO-CFO are confirmed by analyzing X-ray diffractrograms (XRD) using Rietveld method. The average size of nanoparticles and their distribution, crystallographic phase, nanocrystallinity etc. are studied by high-resolution transmission electron microscope (HRTEM). Magnetic hysteresis loops (M-H) of GMO-CFO under zero field cooled (ZFC) and field cooled (FC) conditions are observed at different temperatures down to 5 K. Magnetization vs. temperature (M-T) under ZFC and FC conditions are also recorded. Interestingly, exchange bias (EB) is found at low temperature which suggests the encapsulation of the ferromagnetic (FM) nanoparticles of GMO by the ferrimagnetic nanoparticles of CFO below ~100 K. Enhanced magnetization, EB effect and RT magnetic ordering of GMO-CFO would be interesting for both theoretical and experimental investigations. - Highlights: • Nanoparticles of GdMnO_3 are incorporated in the matrix of CoFe_2O_4. • RT magnetic ordering of GMO nanoparticles in GMO-CFO is observed. • Magnetic property of GMO-CFO is highly enhanced compared to GMO. • Exchange bias is found in GMO-CFO at low temperature.

  13. The effect of FR enhancement in reactive ion beam sputtered Bi, Gd, Al-substituted iron- garnets: Bi2O3 nanocomposite films

    OpenAIRE

    Berzhansky, V.; Shaposhnikov, A.; Karavainikov, A.; Prokopov, A.; Mikhailova, T.; Lukienko, I.; Kharchenko, Yu.; Miloslavskaya, O.; Kharchenko, N.

    2012-01-01

    The effect of considerable Faraday rotation (FR) and figure of merit (Q) enhancement in Bi, Gd, Al-substituted iron garnets: Bi2O3 nano-composite films produced by separate reactive ion beam sputtered Bi:YIG and Bi2O3 films was found. It reached threefold enhancement of the FR and twofold of the Q one on GGG substrates.

  14. Distribution and excretion of inhaled mercury vapour

    Energy Technology Data Exchange (ETDEWEB)

    Gage, J C

    1961-01-01

    Rats have been exposed for varying periods to an atmosphere containing 1 mg/cu.m. mercury vapor. The toxic effects produced showed resemblances to signs of mercurialism in man. An attempt has been made to study the kinetics of absorption and excretion of mercury from measurements of the amounts excreted and stored in the tissues. The efficiency of absorption of mercury by the rat lung is about 50%. A small proportion is excreted into the gut. After about 10 days of continuous exposure a steady state is reached in which excretion balances absorption. During short exposures the turnover of mercury in all tissues except brain is fairly rapid and most of the mercury is cleared from the body within a week after exposure. The urinary excretion of mercury, during the initial stage of storage in the tissues and the final stage of clearance, shows divergencies from the simple exponential pattern; there appears to be a delay mechanism in the kidney which, in intermittent exposures, may result in the occurrence of peak excretion during periods of non-exposure. After more prolonged exposures the mercury in the kidney appears to be converted to a form which is only very slowly excreted. The significance of the urinary excretion of mercury by man after industrial exposure to mercury vapour is discussed. The rat experiments suggest that single measurements will give only limited information concerning industrial conditions, but that an approximate assessment of the total absorbed during a working week would be obtained if it were possible to make a seven-day collection of urine. Repeated measurements after exposure would yield information on the duration of exposure and would have some diagnostic value.

  15. Gd-DTPA: Clinical use in MR imaging of postoperative lumbar recurrent disk herniation and fibrosis

    International Nuclear Information System (INIS)

    Narang, A.K.; Hueftle, M.; Williams, A.; Modic, M.; Davis, D.O.

    1987-01-01

    Gd-DTPA, a paramagnetic MR contrast agent, is most familiarly utilized for delineation of brain and cord abnormalities. Since contrast-enhanced CT may help distinguish epidural fibrosis from recurrent herniated lumbar disk, the efficacy of Gd-DTPA-enhanced MR imaging was evaluated. Symptomatic patients with previous back surgery are being evaluated with pre- and post-Gd-DTPA T1- and T2-weighted images. Results to date (over 40 cases) suggest that this technique will be extremely helpful

  16. Advances in enlargement of melt-textured Gd-Ba-Cu-O superconductors

    International Nuclear Information System (INIS)

    Nariki, S; Sakai, N; Kita, M; Fujikura, M; Murakami, M; Hirabayashi, I

    2006-01-01

    We investigated the fabrication of melt-textured Gd-Ba-Cu-O bulk superconductors with the employment of a Gd 2 BaO 4 (Gd210)-BaCuO 2 -CuO precursor. This enabled us to synthesize a very large Gd-Ba-Cu-O bulk superconductor, 140 mm in diameter. The trapped field distribution measured at 77 K revealed that the sample had no serious cracks, and the maximum field was 2.3 T. The formation behaviour and depressing mechanism of cracking were studied using sintered Gd210-containing precursors. The Ba-Cu-O component in the precursor melted at around 900 deg. C. The formation of such a liquid phase enhanced the densification of the precursor by liquid phase sintering. The mechanical strength of the sintered precursor was increased compared to the conventional Gd123-Gd211 precursor. This will be effective in preventing crack formation in the texturing process of large single-grain samples. The superconducting properties of the bulk sample fabricated from Gd210-containing precursor have been discussed

  17. Superconductivity and magnetism in Ir-doped GdFeAsO

    International Nuclear Information System (INIS)

    Cui, Y.J.; Chen, Y.L.; Cheng, C.H.; Yang, Y.; Jiang, J.; Wang, Y.Z.; Zhang, Y.; Zhao, Y.

    2010-01-01

    The 5d-transition metal, Ir has successfully been doped at Fe site and induced superconductivity in GdFeAsO at T c = 18.9 K and ∼20 atom%. The Ir-doping shortened the c-axis length and stretched the a-axis one, which led to enhance the coupling between the FeAs- and SmO-layer, and to weaken the bonding between Fe and As atom. Paramagnetism was observed in all of the samples, which was resulted from the magnetic Gd ion as in the F-doped GdFeAsO. An upper critical field of GdFe 0.8 Ir 0.2 AsO was extrapolated to around 24 T, much smaller than that of F-doped GdFeAsO owing to a relatively low T c and small value of dH c2 /dT.

  18. Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO for In Vivo MR Imaging of the Liver in an Animal Model.

    Directory of Open Access Journals (Sweden)

    Yu-Ting Kuo

    Full Text Available Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI, play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO, with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA enhanced T1-weighted images and (like SPIO T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824, those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086. Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor

  19. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  20. Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Cowles, Christian C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Siciliano, Edward R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-10-01

    The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

  1. High coercivity Gd-substituted Ba hexaferrites, prepared by chemical coprecipitation

    Science.gov (United States)

    Litsardakis, G.; Manolakis, I.; Serletis, C.; Efthimiadis, K. G.

    2008-04-01

    A series of Gd-substituted Ba hexaferrites with nominal formula (Ba1-xGdx)Oṡ5.25 Fe2O3 (x=0-0.30) were prepared by the chemical coprecipitation method from nitrate precursors and heating at T =800-1200°C for 2h. The samples have been examined by x-ray diffraction, vibrating-sample magnetometer, and scanning electron microscopy methods. Gd substituted samples form single phase materials with the M-type hexaferrite structure at all heating temperatures, in the range of x ⩽0.10-0.20. The saturation magnetization (at 1.8T) varies slightly with x in most cases and, for x =0.05-0.10, it increases up to 66.7Am2/kg, exceeding the value of the unsubstituted hexaferrite. A strong enhancement of the coercivity is observed for all substituted samples, with maximum values Hc=457kA/m for the single-phase x =0.10 sample annealed at 1000°C and Hc=477kA/m for the x =0.25 sample annealed at 1100°C which contains Fe2O3 and GdFeO3 impurities. As the variation of coercivity with either substitution rate (x ) or annealing temperature is not monotonic, three different factors may account for the high coercivities that are obtained: (a) an inhibition of grain growth due to the presence of Gd, (b) a possible inherent effect on magnetocrystalline anisotropy, especially for single phase samples, and (c) a microstructural effect of secondary phases.

  2. Impact of liver cirrhosis on liver enhancement at Gd-EOB-DTPA enhanced MRI at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Verloh, N., E-mail: niklas.verloh@stud.uni-regensburg.de [Department of Radiology, University Hospital Regensburg, Regensburg (Germany); Haimerl, M.; Rennert, J.; Müller-Wille, R.; Nießen, C. [Department of Radiology, University Hospital Regensburg, Regensburg (Germany); Kirchner, G. [Department of Gastroenterology, University Hospital Regensburg, Regensburg (Germany); Scherer, M.N. [Department of Surgery, University Hospital Regensburg, Regensburg (Germany); Schreyer, A.G.; Stroszczynski, C.; Fellner, C.; Wiggermann, P. [Department of Radiology, University Hospital Regensburg, Regensburg (Germany)

    2013-10-01

    Purpose: The purpose of this study was to assess differences in enhancement effects of liver parenchyma between normal and cirrhotic livers on dynamic, Gd-EOB-DTPA enhanced MRI at 3 T. Materials and methods: 93 patients with normal (n = 54) and cirrhotic liver (n = 39; Child–Pugh class A, n = 18; B, n = 16; C, n = 5) underwent contrast-enhanced MRI with liver specific contrast media at 3 T. T1-weighted volume interpolated breath hold examination (VIBE) sequences with fat suppression were acquired before contrast injection, in the arterial phase (AP), in the late arterial phase (LAP), in the portal venous phase (PVP), and in the hepatobiliary phase (HBP) after 20 min. The relative enhancement (RE) of the signal intensity of the liver parenchyma was calculated for all phases. Results: Mean RE was significantly different among all evaluated groups in the hepatobiliary phase and with increasing severity of liver cirrhosis, a decreasing, but still significant reduction of RE could be shown. Phase depending changes of RE for each group were observed. In case of non-cirrhotic liver or Child–Pugh Score A cirrhosis mean RE showed a significant increase between AP, LAP, PVP and HBP. For Child–Pugh B + C cirrhosis RE increased until PVP, however, there was no change in case of B cirrhosis (p = 0.501) and significantly reduced in case of C cirrhosis (p = 0.043) during HBP. Conclusion: RE of liver parenchyma is negatively affected by increased severity of liver cirrhosis, therefore diagnostic value of HBP could be limited in case of Child Pugh B + C cirrhosis.

  3. Impact of liver cirrhosis on liver enhancement at Gd-EOB-DTPA enhanced MRI at 3 Tesla

    International Nuclear Information System (INIS)

    Verloh, N.; Haimerl, M.; Rennert, J.; Müller-Wille, R.; Nießen, C.; Kirchner, G.; Scherer, M.N.; Schreyer, A.G.; Stroszczynski, C.; Fellner, C.; Wiggermann, P.

    2013-01-01

    Purpose: The purpose of this study was to assess differences in enhancement effects of liver parenchyma between normal and cirrhotic livers on dynamic, Gd-EOB-DTPA enhanced MRI at 3 T. Materials and methods: 93 patients with normal (n = 54) and cirrhotic liver (n = 39; Child–Pugh class A, n = 18; B, n = 16; C, n = 5) underwent contrast-enhanced MRI with liver specific contrast media at 3 T. T1-weighted volume interpolated breath hold examination (VIBE) sequences with fat suppression were acquired before contrast injection, in the arterial phase (AP), in the late arterial phase (LAP), in the portal venous phase (PVP), and in the hepatobiliary phase (HBP) after 20 min. The relative enhancement (RE) of the signal intensity of the liver parenchyma was calculated for all phases. Results: Mean RE was significantly different among all evaluated groups in the hepatobiliary phase and with increasing severity of liver cirrhosis, a decreasing, but still significant reduction of RE could be shown. Phase depending changes of RE for each group were observed. In case of non-cirrhotic liver or Child–Pugh Score A cirrhosis mean RE showed a significant increase between AP, LAP, PVP and HBP. For Child–Pugh B + C cirrhosis RE increased until PVP, however, there was no change in case of B cirrhosis (p = 0.501) and significantly reduced in case of C cirrhosis (p = 0.043) during HBP. Conclusion: RE of liver parenchyma is negatively affected by increased severity of liver cirrhosis, therefore diagnostic value of HBP could be limited in case of Child Pugh B + C cirrhosis

  4. Cichorium intybus L. promotes intestinal uric acid excretion by modulating ABCG2 in experimental hyperuricemia.

    Science.gov (United States)

    Wang, Yu; Lin, Zhijian; Zhang, Bing; Nie, Anzheng; Bian, Meng

    2017-01-01

    Excessive production and/or reduced excretion of uric acid could lead to hyperuricemia, which could be a major cause of disability. Hyperuricemia has received increasing attention in the last few decades due to its global prevalence. Cichorium intybus L., commonly known as chicory, is a perennial herb of the asteraceae family. It was previously shown to exert potent hypouricemic effects linked with decreasing uric acid formation in the liver by down-regulating the activity of xanthine oxidase, and increasing uric acid excretion by up-regulating the renal OAT3 mRNA expression. The present study aimed to evaluate its extra-renal excretion and possible molecular mechanism underlying the transporter responsible for intestinal uric acid excretion in vivo. Chicory was administered intragastrically to hyperuricemic rats induced by drinking 10% fructose water. The uricosuric effect was evaluated by determining the serum uric acid level as well as the intestinal uric acid excretion by HPLC. The location and expression levels of ATP-binding cassette transporter, sub-family G, member 2 (ABCG2) in jejunum and ileum were analyzed. The administration of chicory decreased the serum uric acid level significantly and increased the intestinal uric acid excretion obviously in hyperuricemic rats induced by 10% fructose drinking. Staining showed that ABCG2 was expressed in the apical membrane of the epithelium and glands of the jejunum and ileum in rats. Further examination showed that chicory enhanced the mRNA and protein expressions of ABCG2 markedly in a dose-dependent manner in jejunum and ileum. These findings indicate that chicory increases uric acid excretion by intestines, which may be related to the stimulation of intestinal uric acid excretion via down-regulating the mRNA and protein expressions of ABCG2.

  5. A simple polyol-free synthesis route to Gd2O3 nanoparticles for MRI applications: an experimental and theoretical study

    International Nuclear Information System (INIS)

    Ahrén, Maria; Selegård, Linnéa; Söderlind, Fredrik; Linares, Mathieu; Kauczor, Joanna; Norman, Patrick; Käll, Per-Olov; Uvdal, Kajsa

    2012-01-01

    Chelated gadolinium ions, e.g., Gd-DTPA, are today used clinically as contrast agents for magnetic resonance imaging (MRI). An attractive alternative contrast agent is composed of gadolinium oxide nanoparticles as they have shown to provide enhanced contrast and, in principle, more straightforward molecular capping possibilities. In this study, we report a new, simple, and polyol-free way of synthesizing 4–5-nm-sized Gd 2 O 3 nanoparticles at room temperature, with high stability and water solubility. The nanoparticles induce high-proton relaxivity compared to Gd-DTPA showing r 1 and r 2 values almost as high as those for free Gd 3+ ions in water. The Gd 2 O 3 nanoparticles are capped with acetate and carbonate groups, as shown with infrared spectroscopy, near-edge X-ray absorption spectroscopy, X-ray photoelectron spectroscopy and combined thermogravimetric and mass spectroscopy analysis. Interpretation of infrared spectroscopy data is corroborated by extensive quantum chemical calculations. This nanomaterial is easily prepared and has promising properties to function as a core in a future contrast agent for MRI.

  6. A simple polyol-free synthesis route to Gd2O3 nanoparticles for MRI applications: an experimental and theoretical study

    Science.gov (United States)

    Ahrén, Maria; Selegård, Linnéa; Söderlind, Fredrik; Linares, Mathieu; Kauczor, Joanna; Norman, Patrick; Käll, Per-Olov; Uvdal, Kajsa

    2012-08-01

    Chelated gadolinium ions, e.g., Gd-DTPA, are today used clinically as contrast agents for magnetic resonance imaging (MRI). An attractive alternative contrast agent is composed of gadolinium oxide nanoparticles as they have shown to provide enhanced contrast and, in principle, more straightforward molecular capping possibilities. In this study, we report a new, simple, and polyol-free way of synthesizing 4-5-nm-sized Gd2O3 nanoparticles at room temperature, with high stability and water solubility. The nanoparticles induce high-proton relaxivity compared to Gd-DTPA showing r 1 and r 2 values almost as high as those for free Gd3+ ions in water. The Gd2O3 nanoparticles are capped with acetate and carbonate groups, as shown with infrared spectroscopy, near-edge X-ray absorption spectroscopy, X-ray photoelectron spectroscopy and combined thermogravimetric and mass spectroscopy analysis. Interpretation of infrared spectroscopy data is corroborated by extensive quantum chemical calculations. This nanomaterial is easily prepared and has promising properties to function as a core in a future contrast agent for MRI.

  7. Enhanced glass forming ability and refrigerant capacity of a Gd55Ni22Mn3Al20 bulk metallic glass

    International Nuclear Information System (INIS)

    Xia, L.; Chan, K.C.; Tang, M.B.

    2011-01-01

    Highlights: → A new Gd 55 Ni 22 Mn 3 Al 20 bulk metallic glass (BMG) was synthesized by minor Mn addition. → The BMG has enhanced glass forming ability and excellent refrigerant capacity (RC). → The RC of the BMG reaches a high value of 825 J kg -1 under a field of 3979 kA/m. → Its excellent RC is related to its large effective magnetic moment. - Abstract: In this work, a small amount of Mn was added to a Gd 55 Ni 25 Al 20 glass forming alloy, as a replacement for Ni, and a Gd 55 Ni 22 Mn 3 Al 20 bulk metallic glass (BMG) was obtained by suction casting. Its glass forming ability (GFA) was characterized by X-ray diffraction and differential scanning calorimetry, and its magnetic properties were measured using a magnetic property measurement system. It is found that the minor Mn addition can significantly improve both the GFA and the magnetocaloric effect (MCE) of the alloy. The refrigerant capacity (RC) of the BMG can reach a high value of 825 J kg -1 under a field of 3979 kA/m, which is about 29% larger than that of a Gd 55 Ni 25 Al 20 BMG. The effect of the minor Mn addition on the GFA and MCE of the BMG was investigated in the study.

  8. No increase in kidney injury molecule-1 and neutrophil gelatinase-associated lipocalin excretion following intravenous contrast enhanced-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith [Leiden University Medical Center, Department of Thrombosis and Haemostasis, Leiden (Netherlands); Leiden University Medical Center, Department of Nephrology, Leiden (Netherlands); Peppel, Wilke R. van de; Huisman, Menno V. [Leiden University Medical Center, Department of Thrombosis and Haemostasis, Leiden (Netherlands); Sijpkens, Yvo W.J. [Bronovo Hospital, Department of Nephrology, The Hague (Netherlands); Brulez, Harald F.H. [Sint Lucas Andreas Hospital, Department of Nephrology, Amsterdam (Netherlands); Vries, P.M. de [St. Antonius Hospital, Department of Vascular Surgery, Nieuwegein (Netherlands); Nicolaie, Mioara A.; Putter, H. [Leiden University Medical Center, Department of Medical Statistics and Bioinformatics, Leiden (Netherlands); Kooij, W. van der; Kooten, Cees van; Rabelink, Ton J. [Leiden University Medical Center, Department of Nephrology, Leiden (Netherlands)

    2015-07-15

    To analyze kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (N-GAL) excretion post-intravenous contrast enhanced-CT (CE-CT) in patients with chronic kidney disease (CKD). Patients were enrolled in a trial on hydration regimes to prevent contrast-induced acute kidney injury (CI-AKI). Blood and urine samples were taken at baseline, 4 - 6, and 48 - 96 h post CE-CT. Urinary KIM-1 and N-GAL values were normalized for urinary creatinine levels, presented as medians with 2.5 - 97.5 percentiles. Of the enrolled 511 patients, 10 (2 %) were lost to follow-up. CI-AKI occurred in 3.9 % of patients (20/501). Median KIM-1 values were 1.2 (0.1 - 7.7) at baseline, 1.3 (0.1 - 8.6) at 4 - 6 h, and 1.3 ng/mg (0.1 - 8.1) at 48 - 96 h post CE-CT (P = 0.39). Median N-GAL values were 41.0 (4.4 - 3,174.4), 48.9 (5.7 - 3,406.1), and 37.8 μg/mg (3.5 - 3,200.4), respectively (P = 0.07). The amount of KIM-1 and N-GAL excretion in follow-up was similar for patients with and without CI-AKI (P-value KIM-1 0.08, P-value N-GAL 0.73). Neither patient characteristics at baseline including severe CKD, medication use, nor contrast dose were associated with increased excretion of KIM-1 or N-GAL during follow-up. KIM-1 and N-GAL excretion were unaffected by CE-CT both in patients with and without CI-AKI, suggesting that CI-AKI was not accompanied by tubular injury. (orig.)

  9. MRI for characterization of primary tumors in the non-cirrhotic liver: Added value of Gd-EOB-DTPA enhanced hepatospecific phase

    Energy Technology Data Exchange (ETDEWEB)

    Donati, Olivio F.; Hunziker, Roger; Fischer, Michael A. [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Raptis, Dimitri A.; Breitenstein, Stefan [Department of Visceral and Transplant Surgery, Swiss Hepato-Pancreato-Biliary (HPB) Center, University Hospital Zurich, Zurich (Switzerland); Patak, Michael A., E-mail: Michael.Patak@hirslanden.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Clinic Hirslanden, Hirslanden Hospital Group, Zurich (Switzerland)

    2014-07-15

    Purpose: To evaluate the added value of hepatospecific phase in Gd-EOB-DTPA enhanced magnetic resonance imaging (MRI) in patients with primary tumors in non-cirrhotic liver. Methods: Twenty-nine patients (median, 39 years; range, 18–81 years; 11 male) underwent preoperative Gd-EOB-DTPA enhanced MRI including hepatospecific phase after 10 and 20 min of contrast injection at four institutions in Europe, North America and New Zealand. Images were evaluated by three different readers (R1–R3) who characterized liver tumors with and without consultation of the hepatospecific phase images. Confidence in diagnosis was scored on a visual analog scale from 1 to 10. Histopathology (adenoma, n = 5; focal nodular hyperplasia, n = 11 and hepatocellular carcinoma, n = 13) in all patients served as the standard of reference. Differences were evaluated using the McNemar and Wilcoxon signed rank test. Results: Without hepatospecific phase images available, 22 (76%), 19 (66%) and 19 (66%) of 29 tumors were characterized correctly by the three readers respectively. Mean confidence in diagnosis was 6.1, 5.7 and 5.8. With the hepatospecific phase included, characterization of liver tumors did not change significantly with 21 (72%), 23 (79%) and 19 (66%) of 29 tumors diagnosed correctly (p > 0.05). According confidence ratings increased to 6.3, 6.5 and 7.7, respectively. Increase in diagnostic confidence was significant for R2 and R3 (p < 0.05) and independent of reader's experience. Conclusion: The additional hepatospecific phase in Gd-EOB-DTPA enhanced MRI did not significantly increase diagnostic accuracy in characterization of primary tumors in the non-cirrhotic liver. However, 2/3 readers showed a significant increase in diagnostic confidence after consultation of the hepatospecific phase.

  10. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

    Directory of Open Access Journals (Sweden)

    Sonja Kinner

    Full Text Available Preoperative evaluation of potential living liver donors (PLLDs includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w and Gd-EOB-DTPA enhanced T1-weighted (T1w magnetic resonance cholangiography (MRC techniques in the evaluation of PLLDs.30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany using (A 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo fat saturated (fs in axial plane, (B 2D T2w HASTE fs thick slices in coronal plane, (C free breathing 3D T2w TSE (turbo spin echo RESTORE (high-resolution navigator corrected plus (D maximum intensity projections (MIPs, (E T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions plus (F MIPs and (G T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G and with (H inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated.Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622-0.804.3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.

  11. Superconductivity and magnetism in Ir-doped GdFeAsO

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y.J.; Chen, Y.L. [Key Laboratory of Magnetic Levitation and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Cheng, C.H. [School of Materials Science and Engineering, University of New South Wales, Sydney 2052 NSW (Australia); Yang, Y.; Jiang, J.; Wang, Y.Z.; Zhang, Y. [Key Laboratory of Magnetic Levitation and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Zhao, Y., E-mail: yzhao@swjtu.edu.c [Key Laboratory of Magnetic Levitation and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); School of Materials Science and Engineering, University of New South Wales, Sydney 2052 NSW (Australia)

    2010-11-01

    The 5d-transition metal, Ir has successfully been doped at Fe site and induced superconductivity in GdFeAsO at T{sub c} = 18.9 K and {approx}20 atom%. The Ir-doping shortened the c-axis length and stretched the a-axis one, which led to enhance the coupling between the FeAs- and SmO-layer, and to weaken the bonding between Fe and As atom. Paramagnetism was observed in all of the samples, which was resulted from the magnetic Gd ion as in the F-doped GdFeAsO. An upper critical field of GdFe{sub 0.8}Ir{sub 0.2}AsO was extrapolated to around 24 T, much smaller than that of F-doped GdFeAsO owing to a relatively low T{sub c} and small value of dH{sub c2}/dT.

  12. MR imaging of acute myocardial infarction in pigs using Gd-DTPA-labeled dextran

    International Nuclear Information System (INIS)

    Wikstroem, M.; Martinussen, H.J.; Wikstroem, G.; Ericsson, A.; Nyman, R.; Waldenstroem, A.; Hemmingsson, A.

    1992-01-01

    Myocardial infarctions were induced in 12 pigs. In 6 pigs, dextran-(Gd-DTPA)15 (≅ 0.1 mmol Gd/kg b.w.) was injected i.v. 4 to 4.5 hours after coronary artery occlusion. ECG gated MR images were obtained repeatedly before (n=4) and after (n=6) contrast medium injection. Relaxation times in blood samples were measured repeatedly. The animals were scarificed 2 hours after contrast medium administration. The hearts were excised, reaxamined in the MR equipment and stained with triphenyltetrazolium chloride (TTC) in order to define areas of infarction. The remaining 6 pigs were sacrificed 6 hours after occlusion without administration of contrast medium. These hearts were only imaged ex vivo. In vivo, the infarctions could not be identified with or without dextran-(Gd-DTPA)15. Ex vivo, without contrast medium, the infarctions had an increased signal intensity, most pronounced in the T2-weighted images. Dextran-(Gd-DTPA)15 caused a prolonged, pronounced shortening of T1 und T2 in blood samples. The infarct demarcation improved in the T1-weighted images after injection of dextran-(Gd-DTPA)15, due to a moderate enhancement in normal myocardium and a stronger enhancement at the periphery of the infarctions, while the central parts of the infarctions were only weakly enhanced. (orig.)

  13. Dynamic Contrast-Enhanced Magnetic Resonance Imaging with Gd-EOB-DTPA for the Evaluation of Liver Fibrosis Induced by Carbon Tetrachloride in Rats.

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    Full Text Available To investigate the utility of dynamic contrast-enhanced MRI (DCE-MRI with Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA for detecting liver fibrosis induced by carbon tetrachloride (CCl4 in rats.This study was approved by the institutional animal care and use committee. Liver fibrosis in rats was induced by intraperitoneal injection of 1 mL/kg 50% CCl4 twice a week for 4-13 weeks. Control rats were injected with saline. Liver fibrosis was graded using the Metaviar score: no fibrosis (F0, mild fibrosis (F1-F2 and advanced fibrosis (F3-F4. DCE-MRI with Gd-EOB-DTPA was performed for all rats. Ktrans, Kep, Ve and iAUC of the liver parenchyma were measured. Relative enhancement (RE value of the liver was calculated on T1-weighted images at 15, 20 and 25 min after Gd-EOB-DTPA administration.Thirty-five rats were included: no fibrosis (n=13, mild fibrosis (n=11 and advanced fibrosis (n=11. Ktrans and iAUC values were highest in advanced fibrosis group and lowest in no fibrosis group (P<0.05. The area under the receiver operating characteristic curve (AUROC for fibrosis (stages F1 and greater were 0.773 and 0.882 for Ktrans and iAUC, respectively. AUROC for advanced fibrosis were 0.835 and 0.867 for Ktrans and iAUC, respectively. Kep and RE values were not able to differentiate fibrosis stages (all P>0.05.Ktrans and iAUC obtained from DCE-MRI with Gd-EOB-DTPA are useful for the detection and staging of rat liver fibrosis induced by CCl4.

  14. Biliary albumin excretion induced by bile salts in rats is a pathological phenomenon

    International Nuclear Information System (INIS)

    Ohta, M.; Kitani, K.; Kanai, S.

    1989-01-01

    The bile to plasma 125I-albumin concentration ratio (B/P ratio) was examined before and during various bile salt infusions in male Wistar rats that had previously received iv injection of 125I-albumin. Endogenous rat albumin and IgG concentrations in the bile were also determined by a single radial immunodiffusion method. Taurocholate (TC) infusion (1.0 mumol/min/100 g body wt) significantly increased the bile flow rate in the first hr but the flow began to decline in the second hr. The B/P ratio as well as rat albumin (and IgG) excretion into the bile significantly increased as early as 15 min after the start of TC infusion, and the increase became more pronounced in the second hr, when the bile flow began to decrease. Infusion of taurochenodeoxycholate (TCDC, 0.4 mumol/min/100 g) caused a reduction in bile flow 15 min after the start of infusion but the B/P ratio increased 40 times at its peak compared with the basal value before the bile salt infusion. Simultaneous infusion of tauroursodeoxycholate (TUDC, 0.6 mumol/min/100 g) and TCDC not only abolished the cholestasis induced by TCDC but maintained stable choleresis as long as for 2 hr. During this choleretic period, the B/P ration never exceeded the basal value. The choleresis induced by either taurodehydrocholate (TDHC) or bucolome was not accompanied by enhanced albumin excretion. In rats given TDHC infusion, albumin excretion started to increase only after the bile flow began to decline following the initial choleretic period. The enhanced excretion of albumin induced by TC and TCDC is therefore suggested to be caused not by the choleresis per se but by a possible concomitant increase in the communication between sinusoids and bile canaliculi, which eventually leads to cholestasis

  15. Preoperative detection of hepatocellular carcinoma: comparison of combined constrast-enhanced MR imaging and combined CT during arterial portography and CT hepatic arteriography

    International Nuclear Information System (INIS)

    Kwak, H.S.; Kim, C.S.; Lee, J.M.; Seoul National University Medical Research Center

    2004-01-01

    The aim of this study was to compare Gd-DTPA-enhanced dynamic MR images, superparamagnetic iron oxide (SPIO)-enhanced MR images, combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images, vs combined CT arterial portography (CTAP) and CT hepatic arteriography (CTHA), in the detection of hepatocellular carcinoma (HCC) using receiver operating characteristic (ROC) analysis. Twenty-four patients with 38 nodular HCCs (5-60 mm, mean 23.0 mm) were retrospectively analyzed. Image reviews were conducted on a liver segment-by-segment basis. A total of 192 segments, including 36 segments with 38 HCC, were reviewed independently by three radiologists. Each radiologist read four sets of images (set 1, unenhanced and Gd-DTPA-enhanced dynamic MR images; set 2, unenhanced and SPIO-enhanced MR images; set 3, combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images; set 4, combined CTAP and CTHA). To minimize any possible learning bias, the reviewing order was randomized and the reviewing procedure was performed in four sessions at 2-week intervals. The diagnostic accuracy (Az values) for HCCs of combined CTAP and CTHA, combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images, Gd-DTPA-enhanced dynamic MR images, and SPIO-enhanced MR images for all observers were 0.934, 0.963, 0.878, and 0.869, respectively. The diagnostic accuracy of combined CTAP and CTHA and combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images was significantly higher than Gd-DTPA-enhanced dynamic MR images or SPIO-enhanced MR images (p<0.005). The mean specificity of combined CTAP and CTHA (93%) and combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images (95%) was significantly higher than Gd-DTPA-enhanced dynamic MR images (87%) or SPIO-enhanced MR images (88%; p<0.05). Combined Gd-DTPA-enhanced dynamic and SPIO-enhanced MR images may obviate the need for more invasive combined CTAP and CTHA for the preoperative evaluation of patients with HCC

  16. Ferromagnetism in Gd doped ZnO nanowires: A first principles study

    KAUST Repository

    Aravindh, S. Assa

    2014-12-19

    In several experimental studies, room temperature ferromagnetism in Gd-doped ZnO nanostructures has been achieved. However, the mechanism and the origin of the ferromagnetism remain controversial. We investigate the structural, magnetic, and electronic properties of Zn 48O48 nanowires doped with Gd, using density functional theory. Our findings indicate that substitutionally incorporated Gd atoms prefer occupying the surface Zn sites. Moreover, the formation energy increases with the distance between Gd atoms, signifying that no Gd-Gd segregation occurs in the nanowires within the concentration limit of ≤2%. Gd induces ferromagnetism in ZnO nanowires with magnetic coupling energy up to 21 meV in the neutral state, which increases with additional electron and O vacancy, revealing the role of carriers in magnetic exchange. The potential for achieving room temperature ferromagnetism and high TC in ZnO:Gd nanowires is evident from the large ferromagnetic coupling energy (200 meV) obtained with the O vacancy. Density of states shows that Fermi level overlaps with Gd f states with the introduction of O vacancy, indicating the possibility of s-f coupling. These results will assist in understanding experimental findings in Gd-doped ZnO nanowires.

  17. Ferromagnetism in Gd doped ZnO nanowires: A first principles study

    KAUST Repository

    Aravindh, S. Assa; Schwingenschlö gl, Udo; Roqan, Iman S.

    2014-01-01

    In several experimental studies, room temperature ferromagnetism in Gd-doped ZnO nanostructures has been achieved. However, the mechanism and the origin of the ferromagnetism remain controversial. We investigate the structural, magnetic, and electronic properties of Zn 48O48 nanowires doped with Gd, using density functional theory. Our findings indicate that substitutionally incorporated Gd atoms prefer occupying the surface Zn sites. Moreover, the formation energy increases with the distance between Gd atoms, signifying that no Gd-Gd segregation occurs in the nanowires within the concentration limit of ≤2%. Gd induces ferromagnetism in ZnO nanowires with magnetic coupling energy up to 21 meV in the neutral state, which increases with additional electron and O vacancy, revealing the role of carriers in magnetic exchange. The potential for achieving room temperature ferromagnetism and high TC in ZnO:Gd nanowires is evident from the large ferromagnetic coupling energy (200 meV) obtained with the O vacancy. Density of states shows that Fermi level overlaps with Gd f states with the introduction of O vacancy, indicating the possibility of s-f coupling. These results will assist in understanding experimental findings in Gd-doped ZnO nanowires.

  18. Excretion of Different Forms of Zinc by the prawn Palaemon serratus (Pennant)

    International Nuclear Information System (INIS)

    Small, L.F.; Keckes, S.; Fowler, S.W.

    1976-01-01

    Freshly collected speciments of Palaemon serratus from the upper Adriatic Sea were used to determine excretion rates of zinc in ''zinc-free'' water by anodic stripping polarographic techniques. Weight-specific excretion of total zinc varied reciprocally with body weight apparently in a log-log relationship. Weight-specific excretion of ionic-particulate zinc appeared greatest in short term (1-3 hr) experiments, while weight specific excretion of complexed zinc appeared greatest in longer term (4-5 hr) experiments; however, we cannot exclude the possibility that ionic-particulate zinc and dissolved organic compounds were excreted separately and subsequently combined in the water to yield zinc complex. (author)

  19. Excretion of different forms of zinc by the prawn Palaemon serratus (Pennant)

    International Nuclear Information System (INIS)

    Small, L.F.; Keckes, S.; Fowler, S.W.

    1974-01-01

    Freshly collected specimens of Palaemon serratus from the upper Adriatic Sea were used to determine excretion rates of zinc in zinc-free water by anodic stripping polarographic techniques. Weight-specific excretion of total zinc varied reciprocally with body weight, apparently in a log--log relationship. Weight-specific excretion of ionic-particulate zinc appeared greatest in short term (1 to 3 hr) experiments, while weight-specific excretion of complexed zinc appeared greatest in longer term (4 to 5 hr) experiments; however, we cannot exclude the possibility that ionic-particulate zinc and dissolved organic compounds were excreted separately and subsequently combined in the water to yield zinc complex. (auth)

  20. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Kyung Il; Lee, Young Ju [Ajou Univ. College of Medicine, Seoul (Korea, Republic of); Lim, Tae Hwan [Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of)] [and others

    1997-11-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and {sup 99m}Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4{+-}5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42{+-}0.52 and 2.16{+-}0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia.

  1. First-pass perfusion disturbance of coronary artery stenosis: an experimental study using MR imaging with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Lee, Young Ju; Lim, Tae Hwan

    1997-01-01

    In order to determine the value of first-pass MR imaging in the diagnosis of myocardial ischemia, first-pass perfusion abnormality of coronary artery stenosis was observed in MRI after gadopentate dimeglumine(GD-DTPA) enhancement. The left anterior descending(LAD) coronary arteries of six dogs were subjected to approximately 70% stenosis confirmed by coronary angiography. Half an hour after adenosine and 99m Tc-sestamibi infusion, Gd-DTPA(0.2mmol/kg) and methylene blue were administered and termination was induced with potassium chloride. SE T1-weighted and single-photon emission computed tomography(SPECT) images were subsequently obtained and the findings of perfusion defect compared with specimen stain. Three dimensionally reconstructed MR images were used to measure signal intensity(SI) of normal myocardium and perfusion defect from their sectional and total volume. Five of six dogs with LAD artey stenosis ranging from 66% to 73% displayed perfusion defect on MRI, SPECT, and specimen stain, but the remaining dog with stenosis of 58% showed no such defect. MRI showed the perfusion defect as distinct low SI, enabling the measurement of percentage perfusion defect(24.4±5.4%), which increased inferiorly. SI of normal myocardium and perfusion defect decreased inferiorly; their difference indicated stenosis-induced perfusion loss according to section location. Volumetric SI of normal myocardium and perfusion defect were 3.42±0.52 and 2.16±0.45, respectively(p<0.05). Gd-DTPA enhanced MRI displayed first-pass perfusion abnormality of coronary artery stenosis as perfusion defect with distinct low SI; this enabled the measurement of its volume and SI changes according to section location, and thus indicated the value of first-pass MR imaging in the diagnosis of myocardial ischemia

  2. Temperature effects on separation of Gd3+ from Gd-DTPA-folate using nanofiltration method

    Science.gov (United States)

    Rahayu, I.; Indraneli, R. P.; Yuliyati, Y. B.; Anggraeni, A.; Soedjanaatmadja, U. M. S.; Bahti, H. H.

    2018-05-01

    MRI is one of the best techniques in medical diagnostics. Contrast agents are used to improve the visual of organs that are difficult to distinguish through MRI. Gd-DTPA-folate is one of the specific contrast agents against cancer diagnosis, because it has a high affinity to folate receptors. In the complexing Gd-DTPA-folate, does not rule out the complexity step runs imperfectly, so there is still Gd3+ in the Gd-DTPA-folate complex. The separation of Gd3+ from the Gd-DTPA-folate complex is important to eliminate toxic effects on the contrast agent. This study aims to determine the effect of temperature on the separation of Gd-DTPA-folate from Gd3+ with nanofiltration. The method are preparation Gd-DTPA-folate from GdCl3.6H2O and DTPA-folate by reflux method, then separated Gd-DTPA-folate complex from Gd3+ with nanofiltration at variation temperature (40, 41, 42, 43, 44oC ). Then, the values of flux and rejection coefficients were analyzed. The results showed that the optimum temperature for the separation of Gd3+ from Gd-DTPA-folate was achieved at 42.6°C with the rejection coefficient of 24% and the permeate flux of 403 L.m-2.h-1.

  3. Time domain simulation of Gd3+-Gd3+ distance measurements by EPR

    Science.gov (United States)

    Manukovsky, Nurit; Feintuch, Akiva; Kuprov, Ilya; Goldfarb, Daniella

    2017-07-01

    Gd3+-based spin labels are useful as an alternative to nitroxides for intramolecular distance measurements at high fields in biological systems. However, double electron-electron resonance (DEER) measurements using model Gd3+ complexes featured a low modulation depth and an unexpected broadening of the distance distribution for short Gd3+-Gd3+ distances, when analysed using the software designed for S = 1/2 pairs. It appears that these effects result from the different spectroscopic characteristics of Gd3+—the high spin, the zero field splitting (ZFS), and the flip-flop terms in the dipolar Hamiltonian that are often ignored for spin-1/2 systems. An understanding of the factors affecting the modulation frequency and amplitude is essential for the correct analysis of Gd3+-Gd3+ DEER data and for the educated choice of experimental settings, such as Gd3+ spin label type and the pulse parameters. This work uses time-domain simulations of Gd3+-Gd3+ DEER by explicit density matrix propagation to elucidate the factors shaping Gd3+ DEER traces. The simulations show that mixing between the |+½, -½> and |-½, +½> states of the two spins, caused by the flip-flop term in the dipolar Hamiltonian, leads to dampening of the dipolar modulation. This effect may be mitigated by a large ZFS or by pulse frequency settings allowing for a decreased contribution of the central transition and the one adjacent to it. The simulations reproduce both the experimental line shapes of the Fourier-transforms of the DEER time domain traces and the trends in the behaviour of the modulation depth, thus enabling a more systematic design and analysis of Gd3+ DEER experiments.

  4. Air stability and magnetic properties of GdN, TiN, and (Gd,Ti)N nanoparticles

    International Nuclear Information System (INIS)

    Si Pingzhan; Choi, C. J.; Tegus, O.; Brueck, E.; Geng, D. Y.; Zhang, Z. D.

    2008-01-01

    GdN, TiN, and (Gd,Ti)N nanoparticles were prepared by arc evaporating Gd, Ti, and Gd-Ti alloys in N 2 , respectively. Most of these nanoparticles show narrow size distribution with average diameter of 20 nm. Shell/core structure was observed in the (Gd,Ti)N nanoparticles, in which the shell was formed by surface reaction with air. (Gd,Ti)N nanoparticles are more stable than GdN nanoparticles in air due partially to the formation of the protective shell. The Curie temperature of GdN nanoparticles is lower than that of the bulk GdN. Both GdN and (Gd, Ti)N nanoparticles are difficult to reach magnetic saturation and show zero coercivity

  5. Photoluminescence related to Gd3+:N-vacancy complex in GaN:Gd multi-quantum wells

    International Nuclear Information System (INIS)

    Almokhtar, Mohamed; Emura, Shuichi; Koide, Akihiro; Fujikawa, Takashi; Asahi, Hajime

    2015-01-01

    Highlights: • We grew Gd-doped GaN multi-quantum wells (MQWs) with quantum layer thickness of one nm by MBE. • The X-ray absorption near edge structure spectra observed at Gd LIII-edge indicate a nitrogen vacancy adjacent to Gd substituting the Ga ion in Gd-doped GaN MQW. • The photoluminescence of the samples is discussed considering the formation of a Gd 3+ :Nitrogen-vacancy complex. • A model is presented considering exciton-polaron formation trapped in defect sites around the Gd 3+ :N-vacancy complex in Gd-doped GaN MQWs. - Abstract: The photoluminescence of Gd-doped GaN multi-quantum wells (MQWs) is presented and discussed considering the formation of a Gd 3+ :Nitrogen-vacancy (N-vacancy) complex. A lower energy photoluminescence peak was observed for the Gd-doped GaN MQW sample with respect to the main peak assigned to a neutral donor bound exciton (D 0 X) of the undoped GaN MQW sample. The X-ray absorption near edge structure spectrum observed at Gd L III -edge indicates a nitrogen vacancy adjacent to the Gd substituting the Ga ion in Gd-doped GaN MQW sample. Local stresses around the Gd dopants in Gd-doped GaN matrix generated due to the larger diameter of the Gd 3+ ion with respect to the Ga 3+ ion can be relieved by the creation of vacancies. The lower formation energy of N-vacancies in GaN matrix introduce them as a preferred candidate to relieve the generated stresses. A Gd 3+ :N-vacancy complex consisting of a Gd 3+ ion and the created nitrogen vacancy adjacent to the Gd 3+ dopant is likely to form in GaN:Gd matrix. The lower photoluminescence peak energy observed in the Gd-doped GaN MQW sample is assigned to the recombination of an exciton captured at the Gd 3+ :N-vacancy complex forming a small polaron-like state. A model is presented considering the small exciton-polaron population in defect sites captured around the Gd 3+ ions in the Gd-doped GaN

  6. Ferromagnetism in Gd doped ZnO nanowires: A first principles study

    Energy Technology Data Exchange (ETDEWEB)

    Aravindh, S. Assa; Schwingenschloegl, Udo, E-mail: udo.schwingenschloegl@kaust.edu.sa, E-mail: iman.roqan@kaust.edu.sa; Roqan, Iman S., E-mail: udo.schwingenschloegl@kaust.edu.sa, E-mail: iman.roqan@kaust.edu.sa [Physical Sciences and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900 (Saudi Arabia)

    2014-12-21

    In several experimental studies, room temperature ferromagnetism in Gd-doped ZnO nanostructures has been achieved. However, the mechanism and the origin of the ferromagnetism remain controversial. We investigate the structural, magnetic, and electronic properties of Zn{sub 48}O{sub 48} nanowires doped with Gd, using density functional theory. Our findings indicate that substitutionally incorporated Gd atoms prefer occupying the surface Zn sites. Moreover, the formation energy increases with the distance between Gd atoms, signifying that no Gd-Gd segregation occurs in the nanowires within the concentration limit of ≤2%. Gd induces ferromagnetism in ZnO nanowires with magnetic coupling energy up to 21 meV in the neutral state, which increases with additional electron and O vacancy, revealing the role of carriers in magnetic exchange. The potential for achieving room temperature ferromagnetism and high T{sub C} in ZnO:Gd nanowires is evident from the large ferromagnetic coupling energy (200 meV) obtained with the O vacancy. Density of states shows that Fermi level overlaps with Gd f states with the introduction of O vacancy, indicating the possibility of s-f coupling. These results will assist in understanding experimental findings in Gd-doped ZnO nanowires.

  7. Chemical bonding and magnetic properties of gadolinium (Gd) substituted cobalt ferrite

    International Nuclear Information System (INIS)

    Puli, Venkata Sreenivas; Adireddy, Shiva; Ramana, C.V.

    2015-01-01

    Graphical abstract: Room temperature Raman spectra of CoFe 2−x Gd x O 4 (CFGO, x = 0.0–0.3) compounds as a function of wavenumber (cm −1 ). - Highlights: • Gd substituted ferrites were synthesized under controlled concentration. • Gd ion induced lattice dynamical changes are significant. • Enhanced magnetization is observed upon Gd-incorporation in cobalt ferrite. • A correlation between lattice dynamics and magnetic properties is established. - Abstract: Polycrystalline gadolinium (Gd) substituted cobalt ferrites (CoFe 2−x Gd x O 4 ; x = 0–0.3, referred to CFGO) ceramics have been synthesized by solid state reaction method. Chemical bonding, crystal structure and magnetic properties of CFGO compounds have been evaluated as a function of Gd-content. X-ray diffraction (XRD) and Raman spectroscopic analyses confirmed the formation of inverse spinel cubic structure. However, a secondary ortho-ferrite phase (GdFeO 3 ) nucleates for higher values of Gd-content. A considerable increase in the saturation magnetization has been observed upon the initial substitution of Gd (x = 0.1). The saturation magnetization drastically decreases at higher Gd content (x ⩾ 0.3). No contribution from ortho-ferrite GdFeO 3 phase is noted to the magnetic properties. The increase in the magnetic saturation magnetization is attributed to the higher magnetic moment of Gd 3+ (4f 7 ) residing in octahedral sites is higher when compared to that of Fe 3+ (3d 5 ) and as well due to the migration of Co 2+ (3d 7 ) ions from the octahedral to the tetrahedral sites with a magnetic moment aligned anti-parallel to those of rare earth (RE 3+ ) ions in the spinel lattice. Increase in coercivity with increase in Gd 3+ is content is attributed to magnetic anisotropy in the ceramics

  8. NMR measurements in milled GdCo2 and GdFe2 intermetallic compounds

    International Nuclear Information System (INIS)

    Tribuzy, C.V.B.; Guimaraes, A.P.; Biondo, A.; Larica, C.; Alves, K.M.B.

    1998-12-01

    We have used the nuclear magnetic resonance technique to study the magnetic and structural properties of the Gd-Co and Gd-Fe metallic systems, starting with the C15 laves phase intermetallic compounds, and submitting them to a high energy milling process. This leads to the amorphization of the samples, as determined by the X-ray diffraction spectra. For the Gd-Co system the NMR study used the 59 Co nucleus; in the Gd-Fe system, 155,157 Gd and 57 Fe were used. Both systems showed segregation of the pure elements, after a few hours of milling. In the Gd-Co system, a single line, of increasing width, was observed in the 59 Co spectrum. In the Gd-Fe system, the 155 Gd and 157 Gd resonances show three lines, arising from electrical quadrupole interaction. With increasing milling time, the lines broaden, and extra lines appear attributed to a cubic phase of Gd; this interpretation is supported by the X-ray analysis of the samples. The 57 Fe NMR spectrum of this system also informs on the direction of magnetization of the samples in the early stages of milling. From 1 h to 7 h of milling, a spectrum of α-Fe was observed. The study of the NMR line intensity as a function of radio frequency (r.f.) power in Gd Co 2 suggests the existence of regions of the samples with different degrees of disorder. We have observed the persistence of NMR signals from the original intermetallic compounds in the samples with up to 10 h and 7 h of milling, respectively, for Gd Co 2 and Gd Fe 2 . (author)

  9. Gd-DTPA as a paramagnetic contrast agent in MR imaging of focal liver lesions

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Wolf, K.J.; Felix, R.; Weinmann, H.J.

    1986-01-01

    Gd-DTPA enhances signal intensity in healthy liver and in intrahepatic tumors. However, after contrast agent administration, tumor enhances significantly more than liver parenchyma (2α≤ 0.05). Doubling the dose of Gd-DTPA from 0.1 to 0.2 mmol/kg of body weight increases the enhancement of intrahepatic tumors (2α≤ 0.05) and optimizes the contrast between tumor and liver in T1-weighted spin-echo sequences. However, the contrast between tumor and liver on inversion-recovery and T2-weighted images obtained before contrast agent administration is much greater than the difference on T1-weighted images obtained after contrast agent administration (2α≤ 0.05). In fast images the contrast between liver and tumor can be markedly improved by administering Gd-DTPA

  10. Enhancement of encaged electron concentration by Sr(2+) doping and improvement of Gd(3+) emission through controlling encaged anions in conductive C12A7 phosphors.

    Science.gov (United States)

    Zhang, Meng; Liu, Yuxue; Zhu, Hancheng; Yan, Duanting; Yang, Jian; Zhang, Xinyang; Liu, Chunguang; Xu, Changshan

    2016-07-28

    Conductive C12A7:0.1%Gd(3+),y%Sr(2+) powders with different Sr(2+) doping concentrations have been prepared in a H2 atmosphere by a solid state method in combination with subsequent UV-irradiation. The encaged electron concentration could be modulated through tuning Sr(2+) doping and its maximum value reaches 2.3 × 10(19) cm(-3). This is attributed to the competition between enhanced uptake and the release of the encaged anions during their formation and diffusion processes and the suppression of encaged electrons generation due to the increased encaged OH(-) anions and the decreased encaged O(2-) anions. Although there exists encaged electrons and different encaged anions (O(2-), H(-) and OH(-)) in C12A7 conductive powders prepared through the hydrogen route, a dominant local environment around Gd(3+) could be observed using electron spin resonance (ESR) detection. It can be ascribed to the stronger coupling of the encaged OH(-) to the framework of C12A7 than those of the encaged electrons, O(2-) and H(-) anions. In addition, emission of Gd(3+) ions is enhanced under UV or low voltage electron beam excitation and a new local environment around Gd(3+) ions appears through the thermal annealing in air because of the decrease of the encaged OH(-) anions and the increase of the encaged O(2-) anions. Our results suggested that Sr(2+) doping in combination with thermal annealing in air is an effective strategy for increasing the conductive performance and enhancing the emission of rare earth ions doped into C12A7 conductive phosphors for low-voltage field emission displays (FEDs).

  11. Chronological evaluation of liver enhancement in patients with chronic liver disease at Gd-EOB-DTPA-enhanced 3-T MR imaging. Does liver function correlate with enhancement?

    International Nuclear Information System (INIS)

    Nakamura, Shinichi; Utsunomiya, Daisuke; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Nakaura, Takeshi; Morita, Kosuke

    2012-01-01

    The purpose of this study was to investigate the chronological relationship between scan delay and liver enhancement for the hepatobiliary phase on Gd-EOB-DTPA-enhanced MRI and evaluate the effects of liver function on liver enhancement. Hepatobiliary-phase images were retrospectively evaluated in 125 patients with chronic liver disease. Hepatobiliary phase images were obtained at 5, 10, 15, and 20 min after injection. We calculated relative liver enhancement (RLE) at t min after injection by dividing the signal intensity (SI) of the liver at t min by precontrast SI. We compared RLE values at 5, 10, 15, and 20 min and evaluated the detectability of focal hepatic lesions. We analyzed the effect of liver function on RLE with the generalized linear model. There was not significant difference in RLE and lesion detectability at 15 and 20 min. RLE in the Child-Pugh C group was significantly lower than in the Child-Pugh A and B groups. The serum albumin level and prothrombin time were significantly correlated with the liver enhancement. A delay time of 15 min for the hepatobiliary phase was thought to be adequate in patients with mild liver dysfunction. The serum albumin level and prothrombin time would be predictive of liver enhancement in the hepatobiliary phase. (author)

  12. Clinical experience of adverse drug reaction in gadolinium-DTPA enhancement of MRI

    International Nuclear Information System (INIS)

    Kim, Mi Hyae; Hong, Ju Hee; Lee, Yeon Su; Cha, Kyung Soo; Chang, Suk Il; Lee, Young Chul; Kim, Yeong Soo

    1992-01-01

    Gadopentetate dimenglumine(Gd-DTPA) has low toxicity and good tolerance and it is said that the observed adverse drug reaction of Gd-DTPA is compatible to those of iodinated nonionic contrast media. The overall incidence of adverse drug reaction of Gd-DTPA is even lower than those of iodinated nonionic contrast media. Then, the possibility of potential adverse drug reaction of these contrast media is not fully known and recently, many authors have a growing interest in this point. We have taken 2501 cases of MRI and executed 1467 case of Gd-DTPA enhancement scanning(58.7%) and experienced 12 cases of adverse drug reaction(11 cases: mild reaction, 1 case: severs anaphylactic shock) and the overall incidence of our adverse drug reaction of Gd-DTPA was 0.8%. In conclusion, the adverse drug reaction of Gd-DTPA is not rare and the severe adverse drug reaction of Gd-DTPA may occur. So, the possibility of adverse drug reaction after Gd-DTPA injection should always be kept in mind, especially when the patient has a history of reaction to contrast material, allergy(particularly asthma) and cardiac disease. For the safe use of Gd-DTPA, well trained personnel and nearby emergent care facilities should be available

  13. Gadolinium Ethoxybenzyl Diethylenetriamine Pentaacetic Acid (Gd-EOB-DTPA)-Enhanced Magnetic Resonance Imaging and Multidetector-Row Computed Tomography for the Diagnosis of Hepatocellular Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ye, Feng; Liu, Jun; Ouyang, Han

    2015-08-01

    The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.

  14. MR imaging of the central nervous system in infants and children with Gd-DTPA

    International Nuclear Information System (INIS)

    Baierl, P.; Bauer, W.M.; Forster, C.; Haustein, J.

    1988-01-01

    Twenty-five infants and children (aged 2 - 12 years) were examined with MR imaging at 1.0 T. Most of them were younger than 6 years, and general anesthesia was required for the recording of the images. Gd-DTPA was given in doses of 0.1 mmol/kg (Schering). The native MR images were followed by short flip-angle sequences (fast low-angle shot [FLASH] during the flow of Gd-DTPA. After that, T1-weighted images demonstrated contrast enhancement best. No severe adverse effects were seen. The sensitivity of plain MR imaging could not be improved by Gd-DTPA, but contrast enhancement of a lesion proved to be important for the differential diagnosis

  15. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Kawai, Hisashi; Naganawa, Shinji; Ishihara, Shunichi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement. We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above. The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09±1.23, and that on the non-injected side was -0.48±0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually. Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy. (author)

  16. MR with GD-DTPA in the diagnosis of spinal lesions

    International Nuclear Information System (INIS)

    Fenzl, G.; Heywang, S.H.; Vogl, T.

    1988-01-01

    In spinal lesions GD-DTPA has led to a better diagnosis of tumors concerning the extent and differential diagnosis. Important indications for the application of GD-DTPA are intramedullary tumors: excellent information with respect to extent and differentiation cyst from tumor. At extramedullary interadural tumors we got distinction of extramedullary from intramedullary tumors and more information in the differential diagnosis for example in cases of neurinomas and meningiomas. Additional information is also obtained by means of GD-DTPA in extradural tumors: better delineation from the myelon, better possibilities to differentiate between meningiomas, neurinomas and scar and tumor. (orig.) [de

  17. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Strouse, P.J. [Section of Pediatric Radiology, University of Michigan Health System, Ann Arbor (United States); Londy, F.J. [Dept. of Radiology, University of Michigan Hospitals, Ann Arbor, MI (United States); Wakefield, T.W. [Dept. of Surgery, Section of Vascular Surgery, University of Michigan Hospitals, Ann Arbor, MI (United States)

    2001-08-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  18. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Strouse, P.J.; Londy, F.J.; Wakefield, T.W.

    2001-01-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  19. Chemical bonding and magnetic properties of gadolinium (Gd) substituted cobalt ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Puli, Venkata Sreenivas, E-mail: vspuli@utep.edu [Department of Mechanical Engineering, University of Texas, El Paso, TX 79968 (United States); Adireddy, Shiva [Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118 (United States); Ramana, C.V. [Department of Mechanical Engineering, University of Texas, El Paso, TX 79968 (United States)

    2015-09-25

    Graphical abstract: Room temperature Raman spectra of CoFe{sub 2−x}Gd{sub x}O{sub 4} (CFGO, x = 0.0–0.3) compounds as a function of wavenumber (cm{sup −1}). - Highlights: • Gd substituted ferrites were synthesized under controlled concentration. • Gd ion induced lattice dynamical changes are significant. • Enhanced magnetization is observed upon Gd-incorporation in cobalt ferrite. • A correlation between lattice dynamics and magnetic properties is established. - Abstract: Polycrystalline gadolinium (Gd) substituted cobalt ferrites (CoFe{sub 2−x}Gd{sub x}O{sub 4}; x = 0–0.3, referred to CFGO) ceramics have been synthesized by solid state reaction method. Chemical bonding, crystal structure and magnetic properties of CFGO compounds have been evaluated as a function of Gd-content. X-ray diffraction (XRD) and Raman spectroscopic analyses confirmed the formation of inverse spinel cubic structure. However, a secondary ortho-ferrite phase (GdFeO{sub 3}) nucleates for higher values of Gd-content. A considerable increase in the saturation magnetization has been observed upon the initial substitution of Gd (x = 0.1). The saturation magnetization drastically decreases at higher Gd content (x ⩾ 0.3). No contribution from ortho-ferrite GdFeO{sub 3} phase is noted to the magnetic properties. The increase in the magnetic saturation magnetization is attributed to the higher magnetic moment of Gd{sup 3+} (4f{sup 7}) residing in octahedral sites is higher when compared to that of Fe{sup 3+} (3d{sup 5}) and as well due to the migration of Co{sup 2+} (3d{sup 7}) ions from the octahedral to the tetrahedral sites with a magnetic moment aligned anti-parallel to those of rare earth (RE{sup 3+}) ions in the spinel lattice. Increase in coercivity with increase in Gd{sup 3+} is content is attributed to magnetic anisotropy in the ceramics.

  20. Impact of gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance on the non-invasive diagnosis of small hepatocellular carcinoma: a prospective study.

    Science.gov (United States)

    Granito, A; Galassi, M; Piscaglia, F; Romanini, L; Lucidi, V; Renzulli, M; Borghi, A; Grazioli, L; Golfieri, R; Bolondi, L

    2013-02-01

    Gadoxetic acid (Gd-EOB-DTPA) is a 'hepatocyte-specific' contrast agent for magnetic resonance (MR) in both the vascular and the hepatobiliary phases. To evaluate the contribution of the hepatobiliary phase of Gd-EOB-DTPA MR in the diagnosis of small hepatocellular carcinoma (HCC) in cirrhotic patients under surveillance. Between 2008 and 2011, 48 consecutive small (10-30 mm) liver nodules were detected in 33 patients, who prospectively underwent contrast-enhanced ultrasound (CEUS), Gd-EOB-DTPA-enhanced MR and helical-computed tomography (CT) in a blind study. The diagnosis of HCC was established according to AASLD 2005 criteria. Of the 48 nodules, 38 (79%) were diagnosed as HCC, 24 (63%) of them based on AASLD non-invasive criteria, 11 diagnosed at histology and 3 during follow-up. The typical vascular pattern (arterial hypervascularisation and venous/late washout) was detected in 30 (79%) HCC nodules by MR, in 22 (58%) by CT and in 17 (45%) by CEUS. Hypointensity during the MR hepatobiliary phase was observed in all HCC nodules and in 3 nonmalignant nodules (sensitivity 100%, specificity 70%, positive predictive value 93%, negative predictive value 100%, positive likelihood ratio 3.33, negative likelihood ratio 0). Eight (21%) of the 38 HCC nodules, 7 of which lacked the typical vascular features at any of the imaging modalities, showed washout in the portal/venous phase and hypointensity in the hepatobiliary phase at MRI, while this pattern was not detected in any nonmalignant lesion. Gadoxetic acid magnetic resonance may enhance the sensitivity of the non-invasive diagnosis of small hepatocellular carcinoma nodules in cirrhotic patients under surveillance. Double hypointensity in the portal/venous and hepatobiliary phases could be considered a new magnetic resonance pattern, highly suggestive of hypovascular hepatocellular carcinoma. © 2012 Blackwell Publishing Ltd.

  1. Factors affecting the absorption and excretion of lead in the rat

    International Nuclear Information System (INIS)

    Conrad, M.E.; Barton, J.C.

    1978-01-01

    A reliable method for studying lead absorption and excretion in rats is described. Lead absorption occurs primarily in the duodenum where lead enters the epithelial mucosal cells. There is a relative mucosal block for lead with increasing intraluminal doses. Certain substances which bind lead and increase its solubility enhance its absorption. Iron, zinc, and calcium decrease the absorption of lead without affecting its solubility, probably by competing for shared absorptive receptors in the intestinal mucosa. The total body burden of lead does not affect lead absorption. Thus, lead does not have a feedback mechanism which limits absorption. Lead absorption is increased during rapid periods of growth and in iron-deficient animals. It is diminished with starvation and in iron-overloaded animals. The excretion and kinetics of tracer doses of radiolead were quantified. Erythrocytes seem to serve an important role in transport. Excretion occurs in urine and stool. Bile is an important route of excretion in the gut. Although most of a tracer dose is rapidly excreted, the excretory process is limited permitting lead accumulation primarily in bone

  2. Canted magnetic moments at the Gd(0001) surface

    International Nuclear Information System (INIS)

    Li Donggi; Zhang Jiandi; Dowben, P.A.; Tang, H.; Walker, T.G.; Hopster, H.

    1993-01-01

    With spin polarized electron spectroscopies, the authors have investigated ordered Gd(0001) films deposited on W(110). The photoemission features of the gadolinium 5d surface state, the 4f levels, and the background exhibit considerable spin polarization along the same direction in the plane of the film, indicative of ferromagnetic coupling between the surface and the bulk. The 4f spin polarized photoemission data provides strong evidence that the surface 4f polarization differs from the bulk 4f polarization for Gd(0001). The temperature dependent measurements with spin polarized secondary electron spectroscopy conclusively establishes that the surface of clean Gd(0001) possesses a perpendicular polarization component which persists to an enhanced surface Curie temperature. Small amounts of contamination at the surface result in the disappearance of the perpendicular component and, therefore, a more perfect ferromagnetic coupling between the surface and the bulk

  3. Evaluation of Gd and Gd{sup 159} as new approaches for cancer treatment

    Energy Technology Data Exchange (ETDEWEB)

    Galvao, I.; Neves, M.J., E-mail: nevesmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Grupo de Desenvolvimento de Radiofarmacos; Santos, R.G., E-mail: santosr@cdtn.br [Instituto Nacional de Ciencia e Tecnologia em Medicina Molecular (INCT-MM), Belo Horizonte, MG (Brazil)

    2011-07-01

    Metal compounds have shown many biological activities and have been successfully used as anticancer agents such cisplatin. Actually gadolinium (Gd) complexed with a porphyrin Motexafin (MGd) has been investigated as redox-active compound for treatment of cancer. 1{sup 59G}d decays by beta emission with an energy of 970 keV and half-life of 18.59 hours. The de-excitation can be via gamma ray and internal conversion electron emission followed by auger electrons and x rays. Considering all of this 1{sup 59G}d could be a interesting radionuclide to be as a radio therapeutical agent. The aims of this works were to evaluate the cytotoxicity of Gd and 1{sup 59G}d on malignant brain tumors such as glioblastoma multiform, the most frequent brain tumors which has a very poor prognosis. For this purpose, it was used human glioblastoma cell lines T98 (mutant p53) and U87 (wild-type p53) to investigate the cytotoxicity of gadolinium on cell metabolism by MTT assay and also morphological changes, chromatin condensation by DAPI assay and ROS generation. Gadolinium was able to decrease cell viability, the cells presented morphological changes like round shapes and blebs formation after cell treatment with 5x10{sup -6}M of Gd. Nuclear changing and ROS generation occurred in a dose dependent way indicating the cytotoxic effect of Gd. Treatment with 1{sup 59G}d increased all of changes observed with treatment with Gd. These results state for an additive effect of metal toxicity and radioactivity inducing ROS generation as the main mechanism of anti tumoral action of 1{sup 59G}d. The results obtained indicated that the radioactive analogues of Gd have increased cytotoxic effects and gadolinium can be a metal of choice for development of new drugs for cancer treatment. (author)

  4. Engineering Gilbert damping by dilute Gd doping in soft magnetic Fe thin Films

    NARCIS (Netherlands)

    Zhang, W.; Jiang, S.; Wong, P.K.J.; Sun, Li; Wang, Y.K.; Wang, Kai; de Jong, Machiel Pieter; van der Wiel, Wilfred Gerard; van der Laan, G.; Zhai, Y.

    2014-01-01

    By analyzing the ferromagnetic resonance linewidth, we show that the Gilbert damping constant in soft magnetic Fe thin films can be enhanced by ∼6 times with Gd doping of up to 20%. At the same time, the magnetic easy axis remains in the film plane while the coercivity is strongly reduced after Gd

  5. Enhanced and uniform in-field performance in long (Gd, Y)-Ba-Cu-O tapes with zirconium doping fabricated by metal-organic chemical vapor deposition

    International Nuclear Information System (INIS)

    Selvamanickam, V; Guevara, A; Zhang, Y; Kesgin, I; Xie, Y; Carota, G; Chen, Y; Dackow, J; Zhang, Y; Zuev, Y; Cantoni, C; Goyal, A; Coulter, J; Civale, L

    2010-01-01

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I c ) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 μm thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I c in the orientation of field parallel to the c-axis and retain 28% of their self-field I c value at 77 K and 1 T. BaZrO 3 (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of B || c-axis. A retention factor of 36% of the zero-field I c value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  6. Enhanced and uniform in-field performance in long (Gd, Y)-Ba-Cu-O tapes with zirconium doping fabricated by metal-organic chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Guevara, A; Zhang, Y; Kesgin, I [Texas Center for Superconductivity and Department of Mechanical Engineering, University of Houston, Houston, TX 77059 (United States); Xie, Y; Carota, G; Chen, Y; Dackow, J [SuperPower Incorporated, 450 Duane Avenue Schenectady, NY 12304 (United States); Zhang, Y; Zuev, Y; Cantoni, C; Goyal, A [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Coulter, J; Civale, L [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2010-01-15

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I{sub c}) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 {mu}m thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I{sub c} in the orientation of field parallel to the c-axis and retain 28% of their self-field I{sub c} value at 77 K and 1 T. BaZrO{sub 3} (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of B || c-axis. A retention factor of 36% of the zero-field I{sub c} value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  7. Enhanced and Uniform in-Field Performance in Long (Gd,Y)-Ba-Cu-O Tapes with Zirconium Doping Fabricated by Metal Organic Chemical Vapor Deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V. [SuperPower Incorporated, Schenectady, New York; Guevara, A. [University of Houston, Houston; Zhang, Y. [University of Houston, Houston; Kesign, I. [University of Houston, Houston; Xie, Y. Y. [SuperPower Incorporated, Schenectady, New York; Carota, G. [SuperPower Incorporated, Schenectady, New York; Chen, Y. [SuperPower Incorporated, Schenectady, New York; Dackow, J. [SuperPower Incorporated, Schenectady, New York; Zhang, Yifei [ORNL; Zuev, Yuri L [ORNL; Cantoni, Claudia [ORNL; Goyal, Amit [ORNL; Coulter, J. [Los Alamos National Laboratory (LANL); Civale, L. [Los Alamos National Laboratory (LANL)

    2010-01-01

    The influence of Zr doping in (Gd, Y)-Ba-Cu-O ((Gd, Y)BCO) tapes made by metal-organic chemical vapor deposition has been studied with a specific objective of uniform and reproducible enhancement in in-field critical current (I{sub c}) over long lengths. 50 m long tapes with 7.5 and 10 at.% Zr doping in 1 {mu}m thick (Gd, Y)BCO films have been found to exhibit a sharply enhanced peak in I{sub c} in the orientation of field parallel to the c-axis and retain 28% of their self-field I{sub c} value at 77 K and 1 T. BaZrO{sub 3} (BZO) nanocolumn density in the cross-sectional microstructure was found to increase with increasing Zr addition. The end segments of the 50 m long tapes were found to display nearly identical angular dependence of critical current at 77 K and 1 T, indicative of the uniformity in in-field performance over this length. A 610 m long tape was fabricated with 10% Zr doping and a 130 m segment showed a 3.2% uniformity in critical current measured every meter in the orientation of {beta} {parallel} c-axis. A retention factor of 36% of the zero-field I{sub c} value measured at 0.52 T over the 130 m is consistent with that obtained in short samples.

  8. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  9. Improved tumor-targeting MRI contrast agents: Gd(DOTA) conjugates of a cycloalkane-based RGD peptide

    International Nuclear Information System (INIS)

    Park, Ji-Ae; Lee, Yong Jin; Ko, In Ok; Kim, Tae-Jeong; Chang, Yongmin; Lim, Sang Moo; Kim, Kyeong Min; Kim, Jung Young

    2014-01-01

    Highlights: • Development of improved tumor-targeting MRI contrast agents. • To increase the targeting ability of RGD, we developed cycloalkane-based RGD peptides. • Gd(DOTA) conjugates of cycloalkane-based RGD peptide show improved tumor signal enhancement in vivo MR images. - Abstract: Two new MRI contrast agents, Gd-DOTA-c(RGD-ACP-K) (1) and Gd-DOTA-c(RGD-ACH-K) (2), which were designed by incorporating aminocyclopentane (ACP)- or aminocyclohexane (ACH)-carboxylic acid into Gd-DOTA (gadolinium-tetraazacyclo dodecanetetraacetic acid) and cyclic RGDK peptides, were synthesized and evaluated for tumor-targeting ability in vitro and in vivo. Binding affinity studies showed that both 1 and 2 exhibited higher affinity for integrin receptors than cyclic RGDyK peptides, which were used as a reference. These complexes showed high relaxivity and good stability in human serum and have the potential to improve target-specific signal enhancement in vivo MR images

  10. Improved tumor-targeting MRI contrast agents: Gd(DOTA) conjugates of a cycloalkane-based RGD peptide

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji-Ae, E-mail: jpark@kirams.re.kr [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Lee, Yong Jin; Ko, In Ok [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Tae-Jeong; Chang, Yongmin [Institute of Biomedical Engineering, Kyungpook National University, Daegu (Korea, Republic of); Lim, Sang Moo [Department of Nuclear Medicine, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Kyeong Min [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Jung Young, E-mail: jykim@kirams.re.kr [Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2014-12-12

    Highlights: • Development of improved tumor-targeting MRI contrast agents. • To increase the targeting ability of RGD, we developed cycloalkane-based RGD peptides. • Gd(DOTA) conjugates of cycloalkane-based RGD peptide show improved tumor signal enhancement in vivo MR images. - Abstract: Two new MRI contrast agents, Gd-DOTA-c(RGD-ACP-K) (1) and Gd-DOTA-c(RGD-ACH-K) (2), which were designed by incorporating aminocyclopentane (ACP)- or aminocyclohexane (ACH)-carboxylic acid into Gd-DOTA (gadolinium-tetraazacyclo dodecanetetraacetic acid) and cyclic RGDK peptides, were synthesized and evaluated for tumor-targeting ability in vitro and in vivo. Binding affinity studies showed that both 1 and 2 exhibited higher affinity for integrin receptors than cyclic RGDyK peptides, which were used as a reference. These complexes showed high relaxivity and good stability in human serum and have the potential to improve target-specific signal enhancement in vivo MR images.

  11. Water metabolism and modification of tritium excretion in the rat

    International Nuclear Information System (INIS)

    Ichimasa, Y.; Akita, Y.

    1982-01-01

    1. The intake and excretion of tritium were studied in rats exposed to tritiated water vapor. The metabolism of tritium was also investigated in rats given single administrations of tritiated water and in rats given daily administrations (per os or i.p.). The results were essentially in accord with those reported previously. 2. Amounts of drinking water consumed and urine excreted by rats drinking water with 0.15% saccharin were 1.5 to 2 times higher than in rats drinking tap water. The tritium activity in various tissues of rats drinking water with 0.15% saccharin decreased to about half of that of rats drinking tap water. A similar tendency was observed also in rats drinking beer. The diuretic agent sodium acetazolamide also enhanced the urinary excretion of tritium. (author)

  12. Metastatic disease of the spine: MR evaluation with Gd-DTPA

    International Nuclear Information System (INIS)

    Sze, G.; Abramson, A.; Krol, G.; Zimmerman, R.D.; Deck, M.D.F.

    1987-01-01

    Gd-DTPA was used in the MR evaluation of 22 patients with metastatic disease of the spine. Ten patients had epidural lesions; ten patients had intradural extramedullary spread of tumor; two patients had intramedullary metastases. A 1.5-T superconductive magnet with surface coils was used to obtain 3- or 5-mm sagittal and axial sections of the spine. All patients also received myelography and postmyelographic CT. Gd-DTPA was very sensitive to intradural extramedullary disease. Both nodular metastases and nerve root thickening enhanced. Lesions often poorly defined or not visible at all without contrast were easily seen after administration of gadolinium. Gadolinium was also of benefit in patients with intramedullary metastases. Although abnormalities of cord contour and signal were present in noncontrast studies, the region of enhancement was more localized and focal, suggesting that much of the cord enlargement was due to edema. In patients with extradural disease, gadolinium proved to be useful in selected cases. Generally, epidural tumor extension was visible without contrast. In specific cases, administration of gadolinium was beneficial, for example in localizing regions of tumor for biopsy or in distinguishing possible herniated nucleus pulposus from epidural disease. In conclusion, gadolinium is of significant benefit in intradural extramedullary disease. Metastatic lesions of the cord itself may also be more fully evaluated with contrast scans. However, epidural disease will probably prove to be adequately studied without contrast, although gadolinium may be of use in selected applications

  13. Electrical conductivity and chemical stability of BaCe0· 8− xAxGd0 ...

    Indian Academy of Sciences (India)

    ... K. BaCe0.7In0.1Gd0.2O3− and BaCe0.7Zr0.1Gd0.2O3− ceramics exhibit an excellent chemical stability against boiling water. Indium is a suitable doping element to promote the sintering densification and to enhance both electrical conductivity and chemical stability of Gd-doped BaCeO3 at operating temperatures.

  14. Synthesis and Characterization of a Gd-DOTA-D-Permeation Peptide for Magnetic Resonance Relaxation Enhancement of Intracellular Targets

    Directory of Open Access Journals (Sweden)

    Andrew M. Prantner

    2003-10-01

    Full Text Available Many MR contrast agents have been developed and proven effective for extracellular nontargeted applications, but exploitation of intracellular MR contrast agents has been elusive due to the permeability barrier of the plasma membrane. Peptide transduction domains can circumvent this permeability barrier and deliver cargo molecules to the cell interior. Based upon enhanced cellular uptake of permeation peptides with D-amino acid residues, an all-D Tat basic domain peptide was conjugated to DOTA and chelated to gadolinium. Gd-DOTA-D-Tat peptide in serum at room temperature showed a relaxivity of 7.94 ± 0.11 mM−1 sec−1 at 4.7 T. The peptide complex displayed no significant binding to serum proteins, was efficiently internalized by human Jurkat leukemia cells resulting in intracellular T1 relaxation enhancement, and in preliminary T1-weighted MRI experiments, significantly enhanced liver, kidney, and mesenteric signals.

  15. Gd-DTPA in the evaluation of the normal and adnormal cavernous sinus

    International Nuclear Information System (INIS)

    Marks, M.P.; Thrush, A.; Enzmann, D.

    1989-01-01

    This paper reports on Gd-DTPA used in the evaluation of normal and abnormal cavernous sinus anatomy. Twenty-five normal subjects and 11 patients with cavernous sinus invasion were studied before Gd-DTPA enhancement. Normal studies were assessed for the conspicuity of the dural margins, the trigeminal cistern, and intracavernous and exiting cranial nerves. Contrast medium enhancement improved deductibility of the medical cavernous sinus margin (68% vs 38% on precontrast images) and intracavernous cranial nerves. Cranial nerves were inconsistently seen even on postcontrast images (cranial nerve III, 88%; v 1 , 36%, V 2 , 38%). On the abnormal images, contrast enhancement was beneficial in defining the relationship of tumor to parasellar structures, egress of tumor through bony foramina, and compression of the trigeminal cistern

  16. Calculation of the band structure of GdCo2, GdRh2 e GdIr2 by the APW method

    International Nuclear Information System (INIS)

    Carvalho, J.A.B. de.

    1974-03-01

    The band structure of GdCo 2 , GdRh 2 , GdIr 2 has been calculated by the APW method. A histogram of the density of states is presented for each compound. The bands are transition-metal-like, with s-d hybridization near the Fermi level. The 5d character near the Fermi level increases as one goes from Co to Ir

  17. Room temperature magnetic ordering, enhanced magnetization and exchange bias of GdMnO{sub 3} nanoparticles in (GdMnO{sub 3}){sub 0.70}(CoFe{sub 2}O{sub 4}){sub 0.30}

    Energy Technology Data Exchange (ETDEWEB)

    Mitra, A.; Mahapatra, A.S.; Mallick, A.; Chakrabarti, P.K., E-mail: pabitra_c@hotmail.com

    2017-02-15

    Nanoparticles of GdMnO{sub 3} (GMO) are prepared by sol-gel method. To enhance the magnetic property and also to obtain the magnetic ordering at room temperature (RT), nanoparticles of GMO are incorporated in the matrix of CoFe{sub 2}O{sub 4} (CFO). Desired crystallographic phases of CFO, GMO and GMO-CFO are confirmed by analyzing X-ray diffractrograms (XRD) using Rietveld method. The average size of nanoparticles and their distribution, crystallographic phase, nanocrystallinity etc. are studied by high-resolution transmission electron microscope (HRTEM). Magnetic hysteresis loops (M-H) of GMO-CFO under zero field cooled (ZFC) and field cooled (FC) conditions are observed at different temperatures down to 5 K. Magnetization vs. temperature (M-T) under ZFC and FC conditions are also recorded. Interestingly, exchange bias (EB) is found at low temperature which suggests the encapsulation of the ferromagnetic (FM) nanoparticles of GMO by the ferrimagnetic nanoparticles of CFO below ~100 K. Enhanced magnetization, EB effect and RT magnetic ordering of GMO-CFO would be interesting for both theoretical and experimental investigations. - Highlights: • Nanoparticles of GdMnO{sub 3} are incorporated in the matrix of CoFe{sub 2}O{sub 4}. • RT magnetic ordering of GMO nanoparticles in GMO-CFO is observed. • Magnetic property of GMO-CFO is highly enhanced compared to GMO. • Exchange bias is found in GMO-CFO at low temperature.

  18. Organic acid excretion in Penicillium ochrochloron increases with ambient pH

    Directory of Open Access Journals (Sweden)

    Pamela eVrabl

    2012-04-01

    Full Text Available Despite being of high biotechnological relevance, many aspects of organic acid excretion in filamentous fungi like the influence of ambient pH are still insufficiently understood. While the excretion of an individual organic acid may peak at a certain pH value, the few available studies investigating a broader range of organic acids indicate that total organic acid excretion rises with increasing external pH.We hypothesized that this phenomenon might be a general response of filamentous fungi to increased ambient pH. If this is the case, the observation should be widely independent of the organism, growth conditions or experimental design and might therefore be a crucial key point in understanding the function and mechanisms of organic acid excretion in filamentous fungi.In this study we explored this hypothesis using ammonium limited chemostat cultivations (pH 2-7, and ammonium or phosphate limited bioreactor batch cultivations (pH 5 and 7. Two strains of Penicillium ochrochloron were investigated differing in the spectrum of excreted organic acids.Confirming our hypothesis, the main result demonstrated that organic acid excretion in P. ochrochloron was enhanced at high external pH levels compared to low pH levels independent of the tested strain, nutrient limitation and cultivation method. We discuss these findings against the background of three hypotheses explaining organic acid excretion in filamentous fungi, i.e. overflow metabolism, charge balance and aggressive acidification hypothesis.

  19. Enhanced reducibility and electronic conductivity of Nb or W doped Ce0.9Gd0.1O1.95 - δ

    DEFF Research Database (Denmark)

    Chatzichristodoulou, Christodoulos; Ricote, Sandrine; Foghmoes, Søren Preben Vagn

    2015-01-01

    The transport and thermomechanical properties of acceptor (Gd) and donor (Nb or W) co-doped ceria were investigated. The solubility limit of Nb in Ce0.9Gd0.1O2 - δ (CGO10) exceeds 4 at.%, whereas that of W is approximately 2 at.%. Both the thermal and stoichiometric expansion coefficients...... are decreased relative to that of CGO10. Charge compensation of the donor dopants takes place primarily by annihilation of oxide ion vacancies, and a sharp decrease in ionic mobility is observed upon Nb or W doping of CGO10. On the other hand, the n-type electronic conductivity, associated with the reduction...... of Ce4+, increases upon doping with Nb or W, due to enhanced reducibility of cerium. This is beneficial for applications where electronic conductivity is also required, like oxygen permeation membranes. Modeling shows that 4 at.% Nb or W doped CGO10 will deliver higher oxygen fluxes than CGO10, due...

  20. GD-OES and XPS coupling: A new way for the chemical profiling of photovoltaic absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Mercier, Dimitri, E-mail: dimitri.mercier@uvsq.fr [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Bouttemy, Muriel; Vigneron, Jackie [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Chapon, Patrick [HORIBA Jobin Yvon SAS, F-91165 Longjumeau (France); Etcheberry, Arnaud [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France)

    2015-08-30

    Highlights: • The coupling between GD-OES and XPS analysis is a promising way for fine characterization of thin layers. • Crater surface modifications obtained after GD-OES sputtering depend to the plasma gas. • Inversion of the gas flow improves the surface of the crater. • The modified layer is totally eliminated a few seconds after restarting GD-OES sputtering. - Abstract: In this paper, we examine the complementarity of Glow Discharge Optical Emission Spectroscopy (GD-OES) and X Ray Photoelectron Spectroscopy (XPS) for the realization of fine chemical depth profiling of photovoltaic absorbers using Cu(In,Ga)Se{sub 2} (CIGS) materials. The possibility to use sequentially these two techniques is discussed in this paper. We have evaluated the chemical modifications of the crater after GD-OES analyses which depend on the manner of finishing the plasma etching sequence; and we propose different ways to limit or eliminate this effect. For the moment, an intermediate step (wet chemical etching or weak sputtering) is required to obtain a CIGS phase in the crater. Finally, we have demonstrated the possibility to restart the GD-OES analyses of the materials after XPS quantification or GD-OES breaking without modifying the profile shape.

  1. Perpendicular exchange coupling effects in ferrimagnetic TbFeCo/GdFeCo hard/soft structures

    Science.gov (United States)

    Wang, Ke; Wang, Yahong; Ling, Fujin; Xu, Zhan

    2018-04-01

    Bilayers consisting of magnetically hard TbFeCo and soft GdFeCo alloy were fabricated. Exchange-spring and sharp switching in a step-by-step fashion were observed in the TbFeCo/GdFeCo hard/soft bilayers with increasing GdFeCo thickness. A perpendicular exchange bias field of several hundred Oersteds is observed from the shift of minor loops pinned by TbFeCo layer. The perpendicular exchange energy is derived to be in the range of 0.18-0.30 erg/cm2. The exchange energy is shown to increase with the thickness of GdFeCo layer in the bilayers, which can be attributed to the enhanced perpendicular anisotropy of GdFeCo layer in our experimental range.

  2. Aiming for a simpler early arthritis MRI protocol: can Gd contrast administration be eliminated?

    International Nuclear Information System (INIS)

    Stomp, Wouter; Bloem, Johan L.; Reijnierse, Monique; Krabben, Annemarie; Heijde, Desiree van der; Huizinga, Tom W.J.; Helm-van Mil, Annette H.M. van der; Oestergaard, Mikkel

    2015-01-01

    To evaluate whether intravenous gadolinium (Gd) contrast administration can be eliminated when evaluating synovitis and tenosynovitis in early arthritis patients, thereby decreasing imaging time, cost, and invasiveness. Wrist MRIs of 93 early arthritis patients were evaluated by two readers for synovitis of the radioulnar, radiocarpal, and intercarpal joints, according to the Rheumatoid Arthritis MRI Scoring method (RAMRIS), and for tenosynovitis in ten compartments. Scores of MRI images without Gd contrast enhancement were compared to scores obtained when evaluating all, including contrast-enhanced, MRI images as reference. Subsequently, a literature review and pooled analysis of data from the present and two previous studies were performed. At the individual joint/tendon level, sensitivity to detect synovitis without Gd contrast was 91 % and 72 % for the two readers, respectively, with a specificity of 51 % and 81 %. For tenosynovitis, the sensitivity was 67 % and 54 %, respectively, with a specificity of 87 % and 91 %. Pooled data analysis revealed an overall sensitivity of 81 % and specificity of 50 % for evaluation of synovitis. Variations in tenosynovitis scoring systems hindered pooled analyses. Eliminating Gd contrast administration resulted in low specificity for synovitis and low sensitivity for tenosynovitis, indicating that Gd contrast administration remains essential for an optimal assessment. (orig.)

  3. Aiming for a simpler early arthritis MRI protocol: can Gd contrast administration be eliminated?

    Energy Technology Data Exchange (ETDEWEB)

    Stomp, Wouter; Bloem, Johan L.; Reijnierse, Monique [Leiden University Medical Center, Department of Radiology, P.O. Box 9600, Leiden (Netherlands); Krabben, Annemarie; Heijde, Desiree van der; Huizinga, Tom W.J.; Helm-van Mil, Annette H.M. van der [Leiden University Medical Center, Department of Rheumatology, P.O. Box 9600, Leiden (Netherlands); Oestergaard, Mikkel [University of Copenhagen, Copenhagen Center for Arthritis Research, Center for Rheumatology and Spinal Diseases, Glostrup Hospital, Glostrup (Denmark)

    2015-05-01

    To evaluate whether intravenous gadolinium (Gd) contrast administration can be eliminated when evaluating synovitis and tenosynovitis in early arthritis patients, thereby decreasing imaging time, cost, and invasiveness. Wrist MRIs of 93 early arthritis patients were evaluated by two readers for synovitis of the radioulnar, radiocarpal, and intercarpal joints, according to the Rheumatoid Arthritis MRI Scoring method (RAMRIS), and for tenosynovitis in ten compartments. Scores of MRI images without Gd contrast enhancement were compared to scores obtained when evaluating all, including contrast-enhanced, MRI images as reference. Subsequently, a literature review and pooled analysis of data from the present and two previous studies were performed. At the individual joint/tendon level, sensitivity to detect synovitis without Gd contrast was 91 % and 72 % for the two readers, respectively, with a specificity of 51 % and 81 %. For tenosynovitis, the sensitivity was 67 % and 54 %, respectively, with a specificity of 87 % and 91 %. Pooled data analysis revealed an overall sensitivity of 81 % and specificity of 50 % for evaluation of synovitis. Variations in tenosynovitis scoring systems hindered pooled analyses. Eliminating Gd contrast administration resulted in low specificity for synovitis and low sensitivity for tenosynovitis, indicating that Gd contrast administration remains essential for an optimal assessment. (orig.)

  4. Enhancement of CdSiO3: Tb3+ green long-lasting phosphors by co-doping with Re3+ (Re3+=Gd3+, Y3+, La3+) ions

    International Nuclear Information System (INIS)

    Zeng, Wei; Wang, Yuhua; Han, Shaochun; Chen, Wenbo; Li, Gen

    2014-01-01

    CdSiO 3 : Tb 3+ , Re 3+ long-lasting phosphors were synthesized by the conventional high temperature solid-state method. A green-light phosphorescence phenomenon, which was associated with the 5 D 4 → 7 F J (J=6, 5, 4, 3) transitions of the Tb 3+ ion, was observed. Introduction of Re 3+ (Re 3+ =Gd 3+ , Y 3+ , La 3+ ) ions, which deepens the depth (E t ) or/and increases the density (n 0 ) of traps, greatly improved the afterglow properties of CdSiO 3 : Tb 3+ . Possible mechanism of CdSiO 3 : Tb 3+ , Re 3+ was discussed in this work. - Highlights: • CdSiO 3 : Tb 3+ , Re 3+ samples enrich the color of long-lasting afterglow phosphors in CdSiO 3 host. • Both the afterglow intensity and the lasting time are greatly enhanced for the co-doped samples, especially for Cd 0.96 SiO 3 : Tb 0.03 3+ , La 0.01 3+ . • Introduction of Re 3+ (Re 3+ =Gd 3+ , Y 3+ , La 3+ ) ions, which deepens the depth (E t ) or increase density(n 0 ) of traps, greatly improved the afterglow properties of CdSiO 3 : Tb 3+

  5. Feasibility of gadoteric acid for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at the wrist and knee and comparison with Gd-DTPA.

    Science.gov (United States)

    Rehnitz, Christoph; Klaan, Bastian; Do, Thuy; Barié, Alexander; Kauczor, Hans-Ulrich; Weber, Marc-André

    2017-11-01

    To assess the feasibility of gadoteric acid for delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) and to compare the dGEMRIC values obtained using gadoteric acid with those obtained by an equimolar dose of Gd-DTPA. At 3T, dGEMRIC of the wrist was performed twice using a T 1 -weighted 3D-volumetric interpolated breath-hold examination sequence in 16 healthy volunteers (10 women; mean age 26.0 years) using gadoteric acid first and Gd-DTPA 3 weeks later. In addition, 24 patients with knee pain were examined using gadoteric acid (n = 12; seven women; mean age 45.8 years) or Gd-DTPA (n = 12; four women; mean age 47.1 years). T 1 values, the relative decrease in T 1 , and the delta R1 were compared using t-tests. Interobserver agreement was assessed using the intraclass correlation (ICC) between two independent readers. At the wrist, there was no significant difference in delta R1 values (0.34 ± 0.10/s, 95% confidence interval [0.30;0.38]/s for gadoteric acid and 0.32 ± 0.09 [0.29;0.35]/s for Gd-DTPA, P = 0.24) or the relative decrease in T 1 (0.25 ± 0.06 [0.29;0.35] msec for gadoteric acid and 0.24 ± 0.05 [0.22;0.27] msec for Gd-DTPA, P = 0.35). High observer agreement was found at precontrast (ICC = 0.87, P DTPA, P = 0.59) or the relative decrease in T 1 (0.30 ± 0.10 [0.26;0.34] msec for gadoteric acid and 0.33 ± 0.05 [0.30;0.35] msec for Gd-DTPA, P = 0.28). High ICCs of 0.96 (P DTPA. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1433-1440. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Studies on the Sintering Behaviour of UO2-Gd2O3 Nuclear Fuel

    International Nuclear Information System (INIS)

    Durazzo, Michelangelo; Gracher Riella, Humberto

    2008-01-01

    The incorporation of gadolinium directly into nuclear power reactor fuel is important from the point of reactivity compensation and adjustment of power distribution enabling thus longer fuel cycles and optimized fuel utilization. The incorporation of Gd 2 O 3 powder directly into the UO 2 powder by dry mechanical blending is the most attractive process because of its simplicity. Nevertheless, processing by this method leads to difficulties while obtaining sintered pellets with the minimum required density. This is due to blockages during the sintering process. There is little information in published literature about the possible mechanism for this blockage and this is restricted to the hypothesis based on formation of a low diffusivity Gd rich (U,Gd)O 2 phase. Experimental evidences indicated the existence of phases in the (U,Gd)O 2 system with structure different from the fluorite type structure of UO 2 . The apparition of these new phases coincides with the lowering of the density after sintering and with the lowering of the interdiffusion coefficient. However, it has been shown experimentally that the sintering blockage phenomena cannot be explained on the basis of the formation of low diffusivity Gd rich (U,Gd)O 2 phases. The work was continued to investigate other possible blocking mechanism. (authors)

  7. Greater bile acid excretion with soy bean than with cow milk in infants.

    Science.gov (United States)

    Potter, J M; Nestel, P J

    1976-05-01

    The excretion of fecal sterols and bile acids was measured in five infants from the 1st week of life to 2 or 3 months of age as the composition of their diet was changed from cow milk to soy bean milk. Bile acid excretion, adjusted for body weight, was initially lower during the 1st than during the 3rd week, when it reached adult values. The average excretion of bile acids was 6.8 mg/kg per day with soy bean milk and 3.6 mg/kg per day with cow milk. Net sterol excretion (total sterol output minus cholesterol intake) was also twice as high with soy bean milk and probably reflected enhancement of cholesterol re-excretion as well as of synthesis since the cholesterol content of soy beans is nil. However, net sterol excretion remained higher with soy bean than with cow milk even when egg yolk cholesterol was added to the soy bean milk. It is concluded that the substitution of soy bean milk for cow milk, which lowered the plasma cholesterol in all infants (even in the presence of dietary cholesterol) leads to an increase in bile acids and probably also in cholesterol excretion in young infants.

  8. Comparison of acquisition time and dose for late gadolinium enhancement imaging at 3.0 T in patients with chronic myocardial infarction using Gd-BOPTA

    International Nuclear Information System (INIS)

    Doltra, A.; Skorin, A.; Gebker, R.; Klein, C.; Fleck, E.; Kelle, S.; Hamdan, A.; Schnackenburg, B.; Nagel, E.

    2014-01-01

    To compare contrast doses and acquisition times for late gadolinium enhancement (LGE) imaging at 3.0 T using gadobenate dimeglumine (Gd-BOPTA) in patients with chronic myocardial infarction. Thirty-four patients with chronic myocardial infarction were randomised to 0.10, 0.15 and 0.20 mmol/kg of Gd-BOPTA. T1-weighted inversion recovery gradient echo sequences were performed at 5, 10, 15 and 20 min post-administration of contrast in a 3.0-T scanner. Scar-to-myocardium contrast-to-noise ratio (CNR), scar-to-blood CNR, scar size and image quality were assessed. Imaging at 5 min was associated with a lower scar-to-blood CNR in comparison to 10, 15 and 20 min at 0.10 mmol/kg, and in comparison to 15 and 20 min at 0.20 mmol/kg. At 0.10-mmol/kg, imaging at 5 min yielded smaller infarct sizes in comparison to 15 and 20 min. Finally, at 0.20-mmol/kg, imaging at 5 min was associated with poorer image quality in comparison to later times. In LGE imaging at 3.0 T, low doses of Gd-BOPTA perform equally well as higher doses. Early acquisition (5 min) is associated with lower infarct sizes and image quality. Studies with sufficient diagnostic quality can be obtained after 10 min using 0.10 mmol/kg Gd-BOPTA. (orig.)

  9. Selection of optimal pulse sequences for conventional and dynamic MR imaging with Gd-DTPA; A fundamental study

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Miho; Kita, Keisuke; Maeda, Masayuki (Wakayama Medical Coll. (Japan)) (and others)

    1989-11-01

    Gadolinium-DTPA (Gd-DTPA) enhances contrast between tissues in magnetic resonance (MR) imaging. The enhancement of tissues depends partly upon the pulse sequences, and the optimal pulse sequence is also influenced by the tissue cncentration of Gd-DTPA. We prepared phantoms of 25% albumin solutions with various concentrations of Gd-DTPA, and imaged them using various pulse sequences with 1.5-T MR system. We also performed MR imaging of 16 patients with tumors (10 brain tumors and 6 hepatic tumors) before and after intravenous administration of Gd-DTPA (0.1 mmol/kg); 6 patients with hepatic tumors underwent dynamic MR imaging during suspended respiration. We made a theoretical equation to calculate the concentration of Gd-DTPA and estimated its tissue concentration in tumors at 0{approx}0.2 mmol/kg. Within these tissue concentrations, the enhancement-to-noise (E/N) ratio was larger in FISP (flip angle of 90deg, TR pf 300 msec, minimal TE) and SE (TR of 400 msec, minimal TE) sequences than in other sequences observed. These sequences may be preferable for conventional enhanced-MRI. Among the pulse sequences with TR of less than 100 msec, FISP (flip angle of 90deg, TR of less than 100 msec, minimal TE) had the largest E/N ratio; which may be useful for dynamic MRI during suspended respiration. The importance of selecting the optimal pulse sequences according to the imaging modality used will be discussed. (author).

  10. Magnetic resonance imaging of the pancreas in streptozotocin-induced diabetic rats: Gadofluorine P and Gd-DOTA.

    Science.gov (United States)

    Cho, Hye Rim; Lee, Youkyung; Doble, Philip; Bishop, David; Hare, Dominic; Kim, Young-Jae; Kim, Kwang Gi; Jung, Hye Seung; Park, Kyong Soo; Choi, Seung Hong; Moon, Woo Kyung

    2015-05-21

    To investigate the performance of Gadofluorine P-enhanced magnetic resonance imaging (MRI) on the diagnosis of diabetes in a streptozotocin (STZ) -induced diabetic rat model. Fischer 344 rats were treated with STZ. Rats not treated with STZ served as controls. T1-weighted MRI was performed using a 3T scanner before and after the injection of Gd-DOTA or Gadofluorine P (6 diabetic rats, 5 controls). The normalized signal intensity (SI) and the enhancement ratio (ER) of the pancreas were measured at each time point, and the values were compared between the normal and diabetic rats using the Mann-Whitney test. In addition, the values were correlated with the mean islet number. Optimal cut-off values were calculated using a positive test based on receiver operating characteristics. Intrapancreatic Gd concentration after the injection of each contrast media was measured using laser ablation-inductively coupled plasma-mass spectrometry in a separate set of rats (4 diabetic rats, 4 controls for Gadofluorine P; 2, 2 for Gd-DOTA). The normalized SI and ER of the pancreas using Gd-DOTA were not significantly different between diabetic rats and controls. With Gadofluorine P, the values were significantly higher in the diabetic rats than in the control rats 30 min after injection (P DOTA (0.967 vs 0.667, P = 0.085). An increase in normalized SI 30 min after Gadofluorine P was correlated with a decrease in the mean number of islets (r (2) = 0.510, P = 0.014). Intra-pancreatic Gd was higher in rats with Gadofluorine P injection than Gd-DOTA injection (Gadofluorine P vs Gd-DOTA, 7.37 vs 0.00, P < 0.01). A significant difference in the concentration of intrapancreatic Gd was observed between the control and diabetic animals that were sacrificed 30 min after Gadofluorine P injection (control vs diabetic, 3.25 ng/g vs 10.55 ng/g, P < 0.05) CONCLUSION: In this STZ-induced diabetes rat model, Gadofluorine P-enhanced MRI of the pancreas showed high accuracy in the diagnosis of diabetes.

  11. Phase analysis and magnetocaloric properties of Zr substituted Gd-Si-Ge alloys

    International Nuclear Information System (INIS)

    Prabahar, K.; Raj Kumar, D.M.; Manivel Raja, M.; Chandrasekaran, V.

    2011-01-01

    The structure, microstructure, magneto-structural transition and magnetocaloric effect have been investigated in series of (Gd 5-x Zr x )Si 2 Ge 2 alloys with 0≤x≥0.20. X-ray powder diffraction analysis revealed the presence of orthorhombic structure for Zr containing alloys at room temperature in contrast to the monoclinic structure observed in the parent Gd 5 Si 2 Ge 2 alloy. The microstructural studies reveal that, low Zr addition (x≤0.1) resulted in low volume fraction of detrimental Gd 5 Si 3 -type secondary phase compared to that present in the parent alloy. All the Zr containing alloys have shown the presence of only second order magnetic transition unlike the parent alloy showing both first order structural and second order magnetic transition. A moderate (ΔS) M value of -5.5 J/kg K was obtained for the x=0.05 alloy at an enhanced operating temperature of 292 K compared to -7.8 J/kg K at 274 K of the parent alloy for an applied field of 2 T. The interesting feature of Zr (x=0.05) containing alloy is the wide operating temperature range of ∼25 K than that of ∼10-12 K for the parent, which resulted in enhanced net refrigerant capacity of 103 J/kg compared to that of 53 J/kg for the parent alloy. - Research highlights: → Zr addition in Gd 5 Si 2 Ge 2 alloy has been investigated for the first time to reduce the 5:3-type (Gd 5 Si 3 ) secondary phase formed when using commercial grade elements in Gd 5 Si 2 Ge 2 alloy. → It is interesting to observe that Zr addition decrease the volume fraction 5:3. → The refrigerator capacity and transition temperature of Zr added alloy is greater than the pure Gd 5 Si 2 Ge 2 which makes this alloy promising for room temperature application.

  12. Research on urinary excretion of purine derivatives in ruminants: Past, present and future

    International Nuclear Information System (INIS)

    Chen, X.B.; Orskov, E.R.

    2004-01-01

    Research on urinary excretion of purine derivatives (PD), namely allantoin, uric acid, xanthine and hypoxanthine, in ruminants have been carried out with an objective to use the excretion of these purine metabolites as a parameter to estimate the intestinal flow of microbial protein. This paper reviews the published literature, from the first paper in 1931 to the current date. The current status of understanding in some key topics is discussed. The topics include: endogenous excretion, modelling the response of PD excretion to purine absorption, calculation of microbial N supply from PD excretion, use of spot urine measurement, possible use of plasma or milk PD as an alterative index, and applications in ruminant nutrition research. This review also covers the current understanding of PD excretion in different animal species, including sheep, cattle, goats, buffaloes, llamas, camels, yak and deer. Progress in analytical methods for the determination of purine derivatives is also discussed. Finally, areas of future research are highlighted. The paper stresses the need for more studies on metabolism of PD in the tissue, the kinetics of PD in the blood and physiological processes of renal excretion, so as to understand better the mechanism that accounts for the between-species and within species variation in PD excretion. Development of simpler and more rapid methods for defining the endogenous excretion and purine input-output relationship is also an area for future work. (author)

  13. Dosing-time-dependent variation in biliary excretion of flomoxef in rats.

    Science.gov (United States)

    Hishikawa, Shuji; Sugimoto, Koh-ichi; Kobayashi, Eiji; Kumagai, Yuji; Fujimura, Akio

    2003-05-01

    We previously reported that the biliary excretion of flomoxef, an oxacephem antibiotic, was greater after dosing at 21:00 than at 09:00 h in diurnally active human subjects. The present study was undertaken to examine whether the biliary excretion of flomoxef is also dependent on its dosing time in rats. Adult male Wistar rats were housed under light on at 07:00 h and off at 19:00 h. Bile fluid was completely drained through a polyethylene catheter from conscious animals. Flomoxef (20 mg/kg) was injected into the tail vein at 09:00 or 21:00 h by a cross-over design, and drained bile fluid was collected for 8 h after each dosing. The maximum concentration of biliary flomoxef was significantly greater and its total excretion tended to be greater after dosing at 09:00 than 21:00 h. These results suggest the biliary excretion of flomoxef is enhanced after dosing at the beginning of the rest period in rats, as it is in humans.

  14. Intestinal Ileus as a Possible Cause of Hypobicarbonatemia

    Directory of Open Access Journals (Sweden)

    Andres Serrano

    2007-01-01

    Full Text Available The possible occurrence of metabolic acidosis in patients with intestinal ileus is not well recognized. We describe a patient with acute alcohol-induced pancreatitis and a large transverse colon ileus in which plasma bicarbonate dropped rapidly in the absence of an increase in the plasma anion gap. The urinary anion gap and ammonium excretion were consistent with an appropriate renal response to metabolic acidosis and against the possibility of respiratory alkalosis. The cause of the falling plasma bicarbonate was ascribed to intestinal bicarbonate sequestration owing to the enhancement of chloride-bicarbonate exchange in a dilated paralyzed colon.

  15. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Vlahos, L.; Gouliamos, A.; Clauss, W.; Kalovidouris, A.; Hadjiioannou, A.; Athanasopoulou, A.; Trakadas, S.; Papavasiliou, C.

    1992-01-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  16. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Gouliamos, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Clauss, W. [Schering A. G., Berlin (Germany); Kalovidouris, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Hadjiioannou, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Athanasopoulou, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Trakadas, S. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Papavasiliou, C. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece)

    1992-08-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  17. Urine alkalization facilitates uric acid excretion

    Science.gov (United States)

    2010-01-01

    Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet) and others composed of less protein but vegetable-fruit rich food materials (alkali diet). Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+) and anions (Cl-,SO42-,PO4-) necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai) were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-]), indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body. PMID:20955624

  18. Correlation between structural, electrical and magnetic properties of GdMnO3 bulk ceramics

    International Nuclear Information System (INIS)

    Samantaray, S.; Mishra, D.K.; Pradhan, S.K.; Mishra, P.; Sekhar, B.R.; Behera, Debdhyan; Rout, P.P.; Das, S.K.; Sahu, D.R.; Roul, B.K.

    2013-01-01

    This paper reports the effect of sintering temperature on ferroelectric properties of GdMnO 3 (GMO) bulk ceramics at room temperature prepared by the conventional solid state reaction route following slow step sintering schedule. Ferroelectric hysteresis loop as well as sharp dielectric anomaly in pure (99.999%) GMO sintered ceramics has been clearly observed. Samples sintered at 1350 °C become orthorhombic with Pbnm space group and showed frequency independent sharp dielectric anomalies at 373 K and a square type of novel ferroelectric hysteresis loop was observed at room temperature. Interestingly, dielectric anomalies and ferroelectric behavior were observed to be dependent upon sintering temperature of GdMnO 3 . Room temperature dielectric constant (ε r ) value at different frequencies is observed to be abnormally high. The magnetic field and temperature dependent magnetization show antiferromagnetic behavior at 40 K for both 1350 °C and 1700 °C sintered GMO. Present findings showed the possibility of application of GdMnO 3 at room temperature as multifunctional materials. - Highlights: • Preparation of single-phasic polycrystalline GdMnO 3 sample by the solid state sintering route. • Observation of square type P–E hysteresis loop with higher saturation and remnant polarization. • Observation of antiferromagnetic behavior at 40 K in polycrystalline GdMnO 3 . • Possibility of room temperature application of GdMnO 3 as multifunctional material

  19. Thermodynamic calculation of Al-Gd and Al-Gd-Mg phase equilibria checked by key experiments

    International Nuclear Information System (INIS)

    Groebner, J.; Kevorkov, D.; Schmid-Fetzer, R.

    2001-01-01

    The binary Al-Gd and the ternary Al-Gd-Mg systems were calculated using the Calphad method. It is demonstrated that previous interpretation of ternary liquidus temperatures below 700 C must be related to other phase equilibria. The actual ternary liquidus temperatures are much higher, up to some 600 C above the previous interpretation in literature. They are widely governed by the high-melting compounds Al 2 Gd and Al 3 Gd with liquidus surfaces stretching far into the ternary system. A small number of key experiments in this work confirmed the calculated liquidus temperature and the phase relations. The available experimental data in literature fit excellently with the calculation in the binary Al-Gd system. In the ternary Al-Gd-Mg system, which is shown in several sections of the phase diagram, a good agreement can be observed too, considering the necessary reinterpretation of the liquidus temperatures suggested by Rokhlin et al. Ternary solubilities were not found experimentally. The ternary compound Al 4 GdMg (τ) forms in a ternary peritectic reaction at 761 C. (orig.)

  20. Synchrotron Based Structural Investigations of Mass-Selected PtxGd Nanoparticles and a Gd/Pt(111) Single Crystal for Electrochemical Oxygen Reduction

    DEFF Research Database (Denmark)

    Pedersen, Anders Filsøe; Velazquez-Palenzuela, Amado Andres; Masini, Federico

    2015-01-01

    . 134, 16476–16479 (2012). 3. Velazquez-Palenzuela, A. et al. The enhanced activity of mass-selected PtxGd nanoparticles for oxygen electroreduction. J. Catal. [in press] (2015). doi:10.1016/j.jcat.2014.12.012 4. Perez-Alonso, F. J. et al. The Effect of Size on the Oxygen Electroreduction Activity...

  1. The effect of taurocholate on canine bile flow, biliary excretion and concentration of ioglycamide

    International Nuclear Information System (INIS)

    Toetterman, S.; Santavirta, S.; Mankinen, P.; Antila, H.; Lukkari, E.; Goethlin, J.; Korpi-Tommola, T.

    1983-01-01

    The bile acid taurocholate increases the biliary excretion of organic anions, such as sulfobromophthalein (BSP), bilirubin and iopanoic acid. In the present study has been investigated the effect of taurocholate on 1. Canine biliary excretion and concentration of the i.v. contrast medium ioglycamide and 2. Canine bile flow. The experimental model consisted of cholecystectomized, anaesthetized dogs with a fistula, through which the common bile duct could be catheterized and drained. One hour after cannulation, i.v. infusion of ioglycamide at a rate of 4 μmol/min./kg. was started. Two hours after the infusion start a control group received i.v. infusion of saline, while in another a 1.5% sodium taurocholate infusion was started with stepwise increases with 30 min. intervals from 0.4 to 0.8, 1.6 and 3.2 μmol/min./kg. Compared with control, all rates of taurocholate infusion increased bile flow and decreased biliary ioglycamide concentration. Although the bile flow with increasing taurocholate infusion rates was enhanced, the biliary ioglycamide excretion did not increase. The results indicate that ioglycamide and taurocholate are excreted into bile by separate excretion mechanisms. As taurocholate increases the biliary excretion of some other organic anions, it supports the hypothesis that organic anions are excreted into bile by more than two excretion mechanisms, taurocholate affecting only some of them. (orig.)

  2. Pr and Gd co-doped bismuth ferrite thin films with enhanced ...

    Indian Academy of Sciences (India)

    in Pr content, the crystal structures of BPGFO thin films retain rhombohedral (R3c) symmetry accompanied by structure distortion. ... Pr and Gd co-modified BiFeO3 thin film; ferroelectric properties; sol-gel. 1. Introduction. In recent years, great attention has been paid to single- phase BiFeO3 (BFO) multiferroic materials ...

  3. Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent

    International Nuclear Information System (INIS)

    Weinmann, H.J.; Brasch, R.C.; Press, W.R.; Wesbey, G.E.

    1984-01-01

    Chelation of the rare-earth element gadolinium (Gd) with diethylenetriaminepentaacetic acid (DTPA) results in a strongly paramagnetic, stable complex that is well tolerated in animals. The strongly paramagnetic gadolinium complex reduces hydrogen-proton relaxation times even in low concentrations (less than 0.01 mmol/L). The pharmacokinetic behavior of intravenously delivered Gd-DTPA is similar to the well known iodinated contrast agents used in urography and angiography; excretion is predominately through the kidneys with greater than 90% recovery in 24 hr. The intravenous LD 50 of the meglumine salt of Gd-DTPA is 10 mmol/kg for the rat; in vivo there is no evidence of dissociation of the gadolinium ion from the DTPA ligand. The combination of strong proton relaxation, in-vivo stability, rapid urinary excretion, and high tolerance favors the further development and the potential clinical application of gadolinium-DTPA as a contrast enhancer in magnetic resonance imaging

  4. Gd-DTPA L-cystine bisamide copolymers as novel biodegradable macromolecular contrast agents for MR blood pool imaging.

    Science.gov (United States)

    Kaneshiro, Todd L; Ke, Tianyi; Jeong, Eun-Kee; Parker, Dennis L; Lu, Zheng-Rong

    2006-06-01

    The purpose of this study was to synthesize biodegradable Gd-DTPA L-cystine bisamide copolymers (GCAC) as safe and effective, macromolecular contrast agents for magnetic resonance imaging (MRI) and to evaluate their biodegradability and efficacy in MR blood pool imaging in an animal model. Three new biodegradable GCAC with different substituents at the cystine bisamide [R = H (GCAC), CH2CH2CH3 (Gd-DTPA L-cystine bispropyl amide copolymers, GCPC), and CH(CH3)2 (Gd-DTPA cystine bisisopropyl copolymers, GCIC)] were prepared by the condensation copolymerization of diethylenetriamine pentaacetic acid (DTPA) dianhydride with cystine bisamide or bisalkyl amides, followed by complexation with gadolinium triacetate. The degradability of the agents was studied in vitro by incubation in 15 microM cysteine and in vivo with Sprague-Dawley rats. The kinetics of in vivo contrast enhancement was investigated in Sprague-Dawley rats on a Siemens Trio 3 T scanner. The apparent molecular weight of the polydisulfide Gd(III) chelates ranged from 22 to 25 kDa. The longitudinal (T1) relaxivities of GCAC, GCPC, and GCIC were 4.37, 5.28, and 5.56 mM(-1) s(-1) at 3 T, respectively. The polymeric ligands and polymeric Gd(III) chelates readily degraded into smaller molecules in incubation with 15 microM cysteine via disulfide-thiol exchange reactions. The in vitro degradation rates of both the polymeric ligands and macromolecular Gd(III) chelates decreased as the steric effect around the disulfide bonds increased. The agents readily degraded in vivo, and the catabolic degradation products were detected in rat urine samples collected after intravenous injection. The agents showed strong contrast enhancement in the blood pool, major organs, and tissues at a dose of 0.1 mmol Gd/kg. The difference of their in vitro degradability did not significantly alter the kinetics of in vivo contrast enhancement of the agents. These novel GCAC are promising contrast agents for cardiovascular and tumor MRI

  5. Net ion fluxes and ammonia excretion during transport of Rhamdia quelen juveniles

    Directory of Open Access Journals (Sweden)

    Luciano de Oliveira Garcia

    2015-10-01

    Full Text Available The objective of this study was to verify net ion fluxes and ammonia excretion in silver catfish transported in plastic bags at three different loading densities: 221, 286 and 365g L-1 for 5h. A water sample was collected at the beginning and at the end of the transport for analysis of water parameters. There was a significant positive relationship between net ion effluxes and negative relationship between ammonia excretion and loading density, demonstrated by the following equations: Na+: y-24.5-0.27x, r2=0.99, Cl-: y=40.2-0.61x, r2=0.98, K+: y=8.0-27.6x, r2=0.94; ammonia excretion: y=-11.43+0.017x, r2=0.95, where y: net ion flux (mmol kg-1 h-1 or ammonia excretion (mg kg-1h-1 and x: loading density (g. Therefore, the increase of loading density increases net ion loss, but reduces ammonia excretion during the transport of silver catfish, indicating the possibility of ammonia accumulation

  6. Clinical utility of Gd-DTPA subtraction MR imaging for spinal bone metastasis

    International Nuclear Information System (INIS)

    Ando, Keiichi; Murakami, Masao; Kuroda, Yasumasa

    1993-01-01

    Based on reports that Gd-DTPA contributes to the detection of tumors, we used it in 31 cases (97 lesions) of spinal bone metastases. The result was that Gd-DTPA increased the intensity of tumors and the surrounding bone marrow to almost the same level in 53%. To show the metastases clearly, an existing subtraction command system was utilized. The technique included the pixel-by-pixel method, to obtain a Gd-DTPA T1-weighted image (T1WI) subtracted by the original T1WI. The detectability of the subtraction image was improved up to 96%, but was less than the original T1WI (99%). Because of the different imaging rationale between two methods, a means to assess the quality of diagnosis must be proposed. To check the normal background, the same kind of postprocessing was performed in 21 patients without malignancy. Gd-DTPA prefusion was highest in the paravertebral veins, moderate in muscles and epidural fat, and lowest in the spinal cord, intervertebral disk and bone cortex. Gd-DTPA enhanced subtraction MR imaging provides a new diagnostic tool to detect and to assess bone metastasis. (author)

  7. T1 Gd-enhanced compared with CISS sequences in retinoblastoma: superiority of T1 sequences in evaluation of tumour extension

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, Elke R.; Wanke, Isabel; Guengoer, Ali-Riza; Forsting, Michael [University Hospital, Department of Diagnostic and Interventional Neuroradiology, Essen (Germany); Jurklies, Christine [University Hospital Essen, Department of Ophthalmology (Germany)

    2005-01-01

    Background As adequate therapy for retinoblastoma in young children depends on infiltration of extra-retinal structures, diagnostic modalities play an essential role. Methods: In this widely extended study, 80 children with retinoblastoma were studied with MRI (standard fat-suppressed Gd-enhanced T1, T2 thin-slice sequences (additionally with small loop surface coil), constructive interference in steady state (CISS) sequence covering the orbita). The images were analysed by two blinded neuroradiologists. Histology was used as the gold standard. MRI assumed infiltration of extra-retinal structures in 13 of 80 patients of which ten were confirmed by histology. Affected extra-retinal structures were: optic nerve (five, of which two were on CISS and three on T1 with higher image resolution using the surface coil), scleral infiltration (five, of which four on CISS and T1) and ciliary body infiltration (one on CISS and T1). Another 61 enucleated patients did not have any extra-retinal infiltration in histology. The CISS sequence with multiplanar reconstruction was mainly helpful in revealing exact three-dimensional tumour extension with excellent clinical acceptance and pre-surgical planning but T1 fat-suppressed Gd-enhanced images were superior in revealing exact tumour extension. CISS sequences allow to produce excellent anatomical images and to perform multiplanar reconstruction to better demonstrate tumour extension. However, T1-weighted sequences after contrast application are more sensitive (60 versus 40%) in detecting infiltration of the optic nerve but equal in detecting scleral infiltration. (orig.)

  8. Urinary Sodium Excretion and Dietary Sources of Sodium Intake in Chinese Postmenopausal Women with Prehypertension

    Science.gov (United States)

    Liu, Zhao-min; Ho, Suzanne C.; Tang, Nelson; Chan, Ruth; Chen, Yu-ming; Woo, Jean

    2014-01-01

    Background Reducing salt intake in communities is one of the most effective and affordable public health strategies to prevent hypertension, stroke and renal disease. The present study aimed to determine the sodium intake in Hong Kong Chinese postmenopausal women and identify the major food sources contributing to sodium intake and urine excretion. Methods This was a cross-sectional study among 655 Chinese postmenopausal women with prehypertension who were screened for a randomized controlled trial. Data collection included 24 h urine collection for the measurement of sodium, potassium and creatinine, 3-day dietary records, anthropometric measures and questionnaire survey on demographic data and dietary habits. Results The average salt intake estimated from urinary excretion was 7.8±3.2 g/d with 82.1% women above WHO recommendation of 5 g/day. Food groups as soup (21.6%), rice and noodles (13.5%), baked cereals (12.3%), salted/preserved foods (10.8%), Chinese dim sum (10.2%) and sea foods (10.1%) were the major contributors of non-discretionary salt. Discretionary salt use in cooking made a modest contribution to overall intake. Vegetable and fruit intake, age, sodium intake from salted foods, sea foods and soup were the independent determinants of urinary sodium excretion. Conclusions Our data revealed a significant room for reduction of the sodium intake. Efforts to reduce sodium from diets in Hong Kong Chinese postmenopausal women should focus on both processed foods and discretionary salt during cooking. Sodium reduction in soup and increase in fruit intake would be potentially effective strategy for reducing sodium. PMID:25083775

  9. Blood brain barrier and brain tissue injury by Gd-DTPA in uremia-induced rabbits

    International Nuclear Information System (INIS)

    Choi, Sun Seob; Huh, Ki Yeong; Han, Jin Yeong; Lee, Yong Chul; Eun, Choong Gi; Yang, Yeong Il

    1996-01-01

    An experimental study was carried out to evaluate the morphological changes in the blood brain barrier and neighbouring brain tissue caused by Gd-DTPA in uremia-induced rabbits. Bilateral renal arteries and veins of ten rabbits were ligated. Gd-DTPA(0.2mmol/kg) was intravenously injected into seven rabbits immediately after ligation. After MRI, they were sacrificed 2 or 3 days after ligation in order to observe light and electron microscopic changes in the blood brain barrier and brain tissue. MRI findings were normal, except for enhancement of the superior and inferior sagittal sinuses on T1 weighted images in uremia-induced rabbits injected with Gd-DTPA. On light microscopic examination, these rabbits showed perivascular edema and glial fibrillary acidic protein expression: electron microscopic examination showed separation of tight junctions of endothelial cells, duplication/rarefaction of basal lamina, increased lysosomes of neurons with neuronal death, demyelination of myelin, and extravasation of red blood cells. Uremia-induced rabbits injected with Gd-DTPA showed more severe changes than those without Gd-DTPA injection. Injuries to the blood brain barrier and neighbouring brain tissue were aggravated by Gd-DTPA administration in uremia-induced rabbits. These findings appear to be associated with the neurotoxicity of Gd-DTPA

  10. Nickel Dermatitis - Nickel Excretion

    DEFF Research Database (Denmark)

    Menné, T.; Thorboe, A.

    1976-01-01

    Nickel excretion in urine in four females -sensitive to nickel with an intermittent dyshidrotic eruption was measured with flameless atomic absorption. Excretion of nickel was found to be increased in association with outbreaks of vesicles. The results support the idea that the chronic condition ...

  11. Measurement of Gd content in (U,Gd)O2 using thermal gravimetric analysis

    International Nuclear Information System (INIS)

    Kim, Keon Sik; Yang, Jae Ho; Kang, Ki Won; Song, Kun Woo; Kim, Gil Moo

    2004-01-01

    We propose a simple and precise method for measuring the Gd content in the (U,Gd)O 2 pellet by only measuring the weight variation of the pellet during thermal heat treatment in air. The (U,Gd)O 2 fuel pellets were oxidized at 475 deg. C, subsequently heat treated at 1300 deg. C, and then cooled to room temperature in air. The accompanying weight variations were measured using thermo gravimetric analysis (TGA). The measured weight variations were mathematically analyzed with reference to the successive phase reactions during the heat treatment. This method provides an advantage in that the rare-earth element content including Gd can be measured using relatively simple equipment such as an electric furnace and a balance

  12. Synthesis and characterization of (3-Aminopropyl)trimethoxy-silane (APTMS) functionalized Gd2O3:Eu(3+) red phosphor with enhanced quantum yield.

    Science.gov (United States)

    Jain, Akhil; Hirata, G A; Farías, M H; Castillón, F F

    2016-02-12

    We report the surface modification of nanocrystalline Gd2O3:Eu(3+) phosphor by (3-Aminopropyl)trimethoxysilane (APTMS). The nanoparticles were first coated with silica using the Stöber process, and then annealed at 650 °C for 2 h. Afterwards, APTMS was functionalized onto the silica layer to obtain Gd2O3:Eu(3+) nanoparticles bearing amine groups on the surface. The effect of silica coating, and the subsequent annealing process on the crystallization of the nanophosphor were analyzed by x-ray diffraction (XRD). High-resolution transmission electron microscopy (HR-TEM) confirmed the presence of a silica layer of ∼45 nm thickness. X-ray photoelectron (XPS) and Fourier transform infrared (FTIR) spectroscopy confirmed the presence of silica and the amine groups. Photoluminescence (PL) analysis demonstrated an increased emission after functionalization of nanoparticles. Absolute quantum yield (QY) measurements revealed an 18% enhancement in QY in functionalized nanoparticles compared with unmodified nanoparticles, which is of great importance for their biomedical applications.

  13. Synthesis and characterization of (3-Aminopropyl)trimethoxy-silane (APTMS) functionalized Gd2O3:Eu3+ red phosphor with enhanced quantum yield

    Science.gov (United States)

    Jain, Akhil; Hirata, G. A.; Farías, M. H.; Castillón, F. F.

    2016-02-01

    We report the surface modification of nanocrystalline Gd2O3:Eu3+ phosphor by (3-Aminopropyl)trimethoxysilane (APTMS). The nanoparticles were first coated with silica using the Stöber process, and then annealed at 650 °C for 2 h. Afterwards, APTMS was functionalized onto the silica layer to obtain Gd2O3:Eu3+ nanoparticles bearing amine groups on the surface. The effect of silica coating, and the subsequent annealing process on the crystallization of the nanophosphor were analyzed by x-ray diffraction (XRD). High-resolution transmission electron microscopy (HR-TEM) confirmed the presence of a silica layer of ∼45 nm thickness. X-ray photoelectron (XPS) and Fourier transform infrared (FTIR) spectroscopy confirmed the presence of silica and the amine groups. Photoluminescence (PL) analysis demonstrated an increased emission after functionalization of nanoparticles. Absolute quantum yield (QY) measurements revealed an 18% enhancement in QY in functionalized nanoparticles compared with unmodified nanoparticles, which is of great importance for their biomedical applications.

  14. Synthesis and characterization of (3-Aminopropyl)trimethoxy-silane (APTMS) functionalized Gd2O3:Eu3+ red phosphor with enhanced quantum yield

    International Nuclear Information System (INIS)

    Jain, Akhil; Hirata, G A; Farías, M H; Castillón, F F

    2016-01-01

    We report the surface modification of nanocrystalline Gd 2 O 3 :Eu 3+ phosphor by (3-Aminopropyl)trimethoxysilane (APTMS). The nanoparticles were first coated with silica using the Stöber process, and then annealed at 650 °C for 2 h. Afterwards, APTMS was functionalized onto the silica layer to obtain Gd 2 O 3 :Eu 3+ nanoparticles bearing amine groups on the surface. The effect of silica coating, and the subsequent annealing process on the crystallization of the nanophosphor were analyzed by x-ray diffraction (XRD). High-resolution transmission electron microscopy (HR-TEM) confirmed the presence of a silica layer of ∼45 nm thickness. X-ray photoelectron (XPS) and Fourier transform infrared (FTIR) spectroscopy confirmed the presence of silica and the amine groups. Photoluminescence (PL) analysis demonstrated an increased emission after functionalization of nanoparticles. Absolute quantum yield (QY) measurements revealed an 18% enhancement in QY in functionalized nanoparticles compared with unmodified nanoparticles, which is of great importance for their biomedical applications. (paper)

  15. Hepatocellular carcinoma. Comparison between gadolinium and ironoxide enhanced MR imaging

    International Nuclear Information System (INIS)

    Castoldi, M.C.; Fauda, V.; Scaramuzza, D.; Vergnaghi, D.

    2000-01-01

    Purpose of this work is to compare prospectively dynamic gadolinium (Gd)-enhanced with superparamagnetic iron oxide (SPIO)-enhanced MRI for the detection of hepatocellular carcinoma (HCC). Twenty-five patients with histologically proven HCC and liver cirrhosis (28% of them in B or C Child class) underwent dynamic Gd-enhanced MRI and, a few days later, (mean interval: three days) SPIO-enhanced MRI. Only patients with availability of clinical and imaging follow-up for at least seven months were enrolled in this prospective study. MR images were reviewed by two independent radiologists. The readers scored each lesion for the presence of HCC and assigned confidence levels based on a five-grade scale: 1, definitely or almost definitely absent; 2, possibly present; 3, probably present; 4, definitely present; 5, definitely present with optimal liver/lesion contrast or good liver/lesion contrast and morphological signs (intact capsule, intranodular septa, extracapsular infiltration), useful for locoregional treatment planning. A positive diagnostic value was assessed for scores of 3 or higher. Gd-enhanced and SPIO-enhanced MRI found 44 lesions. Eight of twelve lesions visible with a single contrast agent measured less than 1 cm in diameter. HCC detectability was 75% with Gd-enhanced MRI and 97.7% with SPIO-enhanced MRI. SPIO-enhanced T2-weighted TSE images showed significantly higher diagnostic value than SPIO-enhanced T1-T2*GRE images only in three cases, while nodule morphological characteristics (capsule, septa, different cell differentiation components) were better depicted by TSE images. In thi study the combined use of SPIO-enhanced T2-weighted TSE and T1-T2*-weighted GRE sequences showed higher sensitivity than gadolinium-enhanced GRE dynamic imaging (97.7% versus 75%). These results are at least partly related to our study conditions, that is: 1)MRI was performed with a 1T system, 2) both axial and sagittal SPIO-enhanced imaging were performed with respiratory

  16. Urine alkalization facilitates uric acid excretion

    Directory of Open Access Journals (Sweden)

    Seyama Issei

    2010-10-01

    Full Text Available Abstract Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet and others composed of less protein but vegetable-fruit rich food materials (alkali diet. Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+ and anions (Cl-,SO42-,PO4- necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-], indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body.

  17. CW laser properties of Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG mixed crystals

    Science.gov (United States)

    Di, J. Q.; Xu, X. D.; Li, D. Z.; Zhou, D. H.; Wu, F.; Zhao, Z. W.; Xu, J.; Tang, D. Y.

    2011-10-01

    Three mixed crystals, Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG, were grown by Czochralski method. We report the continuous-wave (CW) Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG laser operation under laser diode pumping. The maximum output powers are 4.11, 5.31, and 7.47 W, with slope efficiency of 73.0, 55.3, and 57.1%, respectively. With replacing Lu3+ or Y3+ ions with large Gd3+ ions, the pump efficiency increases.

  18. Sequential gadolinium-DTPA enhanced MRI studies in neuro-Behcet's disease

    International Nuclear Information System (INIS)

    Kazui, S.; Naritomi, H.; Ogawa, M.; Sawada, T.; Imakita, S.; Yamada, N.

    1991-01-01

    Sequential gadolinium-DTPA (Gd-DTPA) enhanced MR images were obtained before and after steroid therapy in a case of neuro-Behcet's disease. Multiple scattered lesions, which could not be detected on pre- and post-contrast CT, were demonstrated mainly in the white matter of the pons and/or the cerebrum with both T1- and T2-weighted images. Some of these lesions, however, were not enhanced at all by infusion of Gd-DTPA. The Gd-DTPA infusion study demonstrated marked enhancement in the white matter of the pons and cerebrum. Some lesions not seen with T2-weighted images were also strongly enhanced by Gd-DTPA infusion at the acute stage. After steroid therapy, the symptoms and abnormal laboratory findings were resolved. The pontine and cerebral lesions on plain MR images remained unchanged even after resolution of the symptoms, suggesting that they were inactive old foci. On the other hand, the lesions detected in the enhancement study before steroid therapy disappeared with the repeat Gd-DTPA enhanced MR images which were performed after resolution of the symptoms. Some active inflammatory lesions in neuro-Behcet's disease may be demonstrated only on Gd-DTPA enhanced MR images. Gd-DTPA enhanced MR imaging appears to be potentially useful for detecting active inflammatory lesions in neuro-Behcet's disease and for evaluating the efficacy of treatment. (orig.)

  19. Biliary excretion of essential trace elements in rats under oxidative stress caused by selenium deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Kosuke; Tsukada, Masamichi [Meiji University, School of Agriculture, Kawasaki, Kanagawa (Japan); Sakuma, Yasunobu; Sasaki, Junya; Matsuoka, Keisuke; Honda, Chikako; Endo, Kazutoyo [Showa Pharmaceutical University, Department of Physical Chemistry, Machida, Tokyo (Japan); Matsumoto, Ken-ichiro; Anzai, Kazunori [National Institute of Radiological Science, Research Center for Charged Particle Therapy, Chiba (Japan); Enomoto, Shuichi [The Institute of Physical and Chemical Research (RIKEN), Radioisotope Technology Division, Cyclotron Center, Wako, Saitama (Japan); Okayama University, Department of Analytical Chemistry, School of Pharmacy, Okayama (Japan)

    2011-11-15

    The excretion of essential trace elements, namely, Se, Sr, As, Mn, Co, V, Fe, and Zn into the bile of Se-deficient (SeD) Wistar male rats was studied using the multitracer (MT) technique, and instrumental neutron activation analysis (INAA). Normal and Se-control (SeC) rat groups were used as reference groups to compare the effects of Se levels on the behaviors of the essential trace elements. The excretion (% dose) of Se, Sr, As, Mn, Co, and V increased with Se levels in the liver. The biliary excretion of Mn and As dramatically enhanced for SeC rats compared with SeD rats, while that of V accelerated a little for SeC rats. The radioactivity levels of {sup 59}Fe and {sup 65}Zn in the MT tracer solution were insufficient to measure their excretion into bile. The role of glutathione and bilirubin for biliary excretion of the metals was discussed in relation to Se levels in rat liver. (orig.)

  20. Haemophilic arthropathy of the knee. Gd-DTPA enhanced MRT. Clinical and radiological correlation; Haemophile Arthropathie des Kniegelenkes. Gd-DTPA-verstaerkte MRT: klinische und roentgenologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. [Radiologische Universitaetsklinik, Bonn (Germany); Kunze, V. [Radiologische Universitaetsklinik, Bonn (Germany); Hamann, M. [Radiologische Universitaetsklinik, Bonn (Germany); Eickhoff, H. [Orthopaedische Klinik, Krankenhaus Troisdorf (Germany); Koch, W. [Orthopaedische Klinik, Krankenhaus Troisdorf (Germany); Oldenburg, J. [Inst. fuer Experimentelle Haematologie und Transfusionsmedizin, Bonn (Germany); Reiser, M. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Steudel, A. [Radiologische Universitaetsklinik, Bonn (Germany)

    1994-02-01

    17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRT before and after i.v. bolus injection of Gadolinium-DTPA (0,1 mmol/kg body weight). After contrast enhancement, synovial proliferations exhibited an increase of signal intensity (SI) of FFE and SE images of 47.7% and 37.4% respectively, whereas muscle and fatty tissue, tendons, bone marrow and joint effusion revealed only minor increase in SI. The gradient of signal intensity (ratio SI/time) of pannus was 39,6% min. Gd-DTPA enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.) [Deutsch] Es wurden 17 Patienten mit einer haemophilen Arthropathie der Kniegelenke mit der statischen und dynamischen MRT vor und nach i.v. Bolusgabe von Gadolinium-DTPA (0,1 mmol/kg KG) untersucht. Nach Kontrastmittelgabe konnte ein Anstieg der Signalintensitaet des Pannus von 37,4% auf SE- und von 47,7% auf FFE-Aufnahmen gemessen werden. Der Gradient des Signalintensitaetsanstieges (%/Zeit) lag fuer Pannus bei 39,6%/min. Die Kontrastmittelgabe steigerte die Abgrenzbarkeit des Pannus von Gelenkerguss und den Gelenkbinnenstrukturen. Begleitend durchgefuehrte klinische und roentgenologische Bewertungen des Schweregrades der Arthropathie korrelierten nicht mit dem Signalintensitaetsverhalten des Pannus nach Kontrastmittelgabe. (orig.)

  1. Hyperintense hepatocellular carcinoma on gadolinium-enhanced hepatic MRI

    International Nuclear Information System (INIS)

    Yoshikawa, Jun; Matsui, Osamu; Kadoya, Masumi; Gabata, Toshifumi; Arai, Kazunori; Takashima, Tsutomu

    1992-01-01

    We reported a phenomenon in which some hepatocellular carcinomas (HHCs) visualized as hypointense on plain T1 weighted MR images became hyperintense on gadolinium-DTPA (Gd-DTPA) (0.06∼0.23 mmol/kg) enhanced delayed images. Gd-DTPA enhanced images (using a super conducting magnet operating at 1.5T) of 44 HCCs were studied in comparison with contrast enhanced CT using 30∼80g of iodine. Six of 44 HCCs (14%) which were visualized as hypointense on plain T1 weighted image became hyperintense on delayed Gd-DTPA enhanced images. Although these were visualized as low intensity areas on both plain and enhanced CT, the contrast between HCC and the surrounding liver was small on post contrast CT. These findings were thought to be due to a stronger enhancement effect of Gd-DTPA than that of iodine. (author)

  2. Peculiar features of thermal emission of GdB4 and GdB6 single crystals

    International Nuclear Information System (INIS)

    Ostrovskij, E.K.; Taran, A.A.; Kovalev, A.V.; Tkachenko, V.F.; Dudnik, E.M.; Matvienko, A.A.

    1990-01-01

    Thermoemission parameters of single crystals (410) GdB 4 and (110) GdB 6 are studied. Work function is calculated by total current. It is stated that work function of GdB 6 within temperature range of 1500-1880 K after 80 h of annealing varies from 2.95 to 3.10 eV practically with the same temperature coefficient as GdB 4 , i.e. 4.1x10 -4 eV/K. It is shown that single crystal gadolinium hexaboride during the high-temperature annealing in the surface region (∼70 mm) is transformed into gadolinium tetraboride. Influence of free air has been first studied on the GdB 4 emissivity which is determined to increase to p=1.3x10 -2 Pa within the range of T=1640-1840 K

  3. Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries

    NARCIS (Netherlands)

    Westenberg, J.J.M.; Geest, van der R.J.; Wasser, M.N.J.M.; Linden, van der E.L.; Walsum, van T.; Assen, van H.C.; Roos, de A.; Vanderschoot, J.; Reiber, J.H.C.

    2000-01-01

    In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semi-automatically in maximum intensity

  4. Optimizing Water Exchange Rates and Rotational Mobility for High-Relaxivity of a Novel Gd-DO3A Derivative Complex Conjugated to Inulin as Macromolecular Contrast Agents for MRI.

    Science.gov (United States)

    Granato, Luigi; Vander Elst, Luce; Henoumont, Celine; Muller, Robert N; Laurent, Sophie

    2018-02-01

    Thanks to the understanding of the relationships between the residence lifetime τ M of the coordinated water molecules to macrocyclic Gd-complexes and the rotational mobility τ R of these structures, and according to the theory for paramagnetic relaxation, it is now possible to design macromolecular contrast agents with enhanced relaxivities by optimizing these two parameters through ligand structural modification. We succeeded in accelerating the water exchange rate by inducing steric compression around the water binding site, and by removing the amide function from the DOTA-AA ligand [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid mono(p-aminoanilide)] (L) previously designed. This new ligand 10[2(1-oxo-1-p-propylthioureidophenylpropyl]-1,4,7,10-tetraazacyclodecane-1,4,7-tetraacetic acid (L 1 ) was then covalently conjugated to API [O-(aminopropyl)inulin] to get the complex API-(GdL 1 )x with intent to slow down the rotational correlation time (τ R ) of the macromolecular complex. The evaluation of the longitudinal relaxivity at different magnetic fields and the study of the 17 O-NMR at variable temperature of the low-molecular-weight compound (GdL 1 ) showed a slight decrease of the τ M value (τM310 = 331 ns vs. τM310 = 450 ns for the GdL complex). Consequently to the increase of the size of the API-(GdL 1 )x complex, the rotational correlation time becomes about 360 times longer compared to the monomeric GdL 1 complex (τ R  = 33,700 ps), which results in an enhanced proton relaxivity. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  5. The effect of Gd doping on the electrical and photoelectrical properties of Gd:ZnO/p-Si heterojunctions

    Energy Technology Data Exchange (ETDEWEB)

    Baturay, Silan [Department of Physics, Faculty of Science, Dicle University, 21280 Diyarbakir (Turkey); Ocak, Yusuf Selim, E-mail: yusufselim@gmail.com [Department of Science, Faculty of Education, Dicle University, 21280 Diyarbakir (Turkey); Science and Technology Application and Research Center, Dicle University, 21280 Diyarbakir (Turkey); Kaya, Derya [Department of Physics, Institute of Natural Applied Sciences, Dicle University, 21280 Diyarbakir (Turkey)

    2015-10-05

    Highlights: • Undoped and Gd doped ZnO thin films were deposited onto p-Si semiconductor. • The Gd:ZnO/p-Si heterojunctions were compared with undoped ZnO/p-Si heterojunction. • A strong effect of Gd doping on the performance of the devices were reported. - Abstract: Undoped ZnO thin films, as well as 1%, 3% and 5% Gd-doped ZnO films, were deposited on p-type Si using spin coating. The structural properties of these thin films were analysed using X-ray diffraction, and the current–voltage (I–V) and capacitance–voltage (C–V) characteristics of the Gd:ZnO/p-Si heterojunctions were compared with those of the undoped ZnO/p-Si heterojunctions. We found that Gd doping had a strong effect on the performance of the devices, and that the Gd:ZnO/p-Si heterojunctions formed with 1% Gd-doped ZnO were the most strongly rectifying, and had the highest barrier height and the lowest series resistance. Furthermore, the I–V measurements of the 1% Gd-doped ZnO/p-Si heterojunction exhibited the strongest response to light.

  6. Molecular imaging of alpha v beta3 integrin expression in atherosclerotic plaques with a mimetic of RGD peptide grafted to Gd-DTPA.

    Science.gov (United States)

    Burtea, Carmen; Laurent, Sophie; Murariu, Oltea; Rattat, Dirk; Toubeau, Gérard; Verbruggen, Alfons; Vansthertem, David; Vander Elst, Luce; Muller, Robert N

    2008-04-01

    The integrin alpha v beta3 is highly expressed in atherosclerotic plaques by medial and intimal smooth muscle cells and by endothelial cells of angiogenic microvessels. In this study, we have assessed non-invasive molecular magnetic resonance imaging (MRI) of plaque-associated alpha v beta3 integrin expression on transgenic ApoE-/- mice with a low molecular weight peptidomimetic of Arg-Gly-Asp (mimRGD) grafted to gadolinium diethylenetriaminepentaacetate (Gd-DTPA-g-mimRGD). The analogous compound Eu-DTPA-g-mimRGD was employed for an in vivo competition experiment and to confirm the molecular targeting. The specific interaction of mimRGD conjugated to Gd-DTPA or to 99mTc-DTPA with alpha v beta3 integrin was furthermore confirmed on Jurkat T lymphocytes. The mimRGD was synthesized and conjugated to DTPA. DTPA-g-mimRGD was complexed with GdCl3.6H2O, EuCl3.6H2O, or with [99mTc(CO)3(H2O)3]+. MRI evaluation was performed on a 4.7 T Bruker imaging system. Blood pharmacokinetics of Gd-DTPA-g-mimRGD were assessed in Wistar rats and in c57bl/6j mice. The presence of angiogenic blood vessels and the expression of alpha v beta3 integrin were confirmed in aorta specimens by immunohistochemistry. Gd-DTPA-g-mimRGD produced a strong enhancement of the external structures of the aortic wall and of the more profound layers (possibly tunica media and intima). The aortic lumen seemed to be restrained and distorted. Pre-injection of Eu-DTPA-g-mimRGD diminished the Gd-DTPA-g-mimRGD binding to atherosclerotic plaque and confirmed the specific molecular targeting. A slower blood clearance was observed for Gd-DTPA-g-mimRGD, as indicated by a prolonged elimination half-life and a diminished total clearance. The new compound is potentially useful for the diagnosis of vulnerable atherosclerotic plaques and of other pathologies characterized by alpha v beta3 integrin expression, such as cancer and inflammation. The delayed blood clearance, the significant enhancement of the signal

  7. 3-Methylhistidine excretion in myotonic dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Griggs, R.C.; Moxley, R.T. III; Forbes, G.B.

    1980-12-01

    3-Methylhistidine (3-MH) excretion reflects the rate of muscle protein catabolism, since 3-MH occurs almost exclusively in muscle actin and myosin and is not reutilized or catabolized. We studied 3-MH excretion in 9 patients with myotonic dystrophy, 8 normals, and 10 disease controls with Duchenne dystrophy and other disorders. 3-MH excretion was expressed relative to muscle mass as determined by both urinary creatinine and total body potassium (/sup 40/K method). Absolute 3-MH excretion was decreased in myotonic dystrophy patients but was normal when related to muscle mass. The finding of normal 3-MH excretion in myotonic dystrophy suggests that the muscle wasting in this disorder results from impaired anabolic processes rather than accelerated muscle destruction.

  8. 3-Methylhistidine excretion in myotonic dystrophy

    International Nuclear Information System (INIS)

    Griggs, R.C.; Moxley, R.T. III; Forbes, G.B.

    1980-01-01

    3-Methylhistidine (3-MH) excretion reflects the rate of muscle protein catabolism, since 3-MH occurs almost exclusively in muscle actin and myosin and is not reutilized or catabolized. We studied 3-MH excretion in 9 patients with myotonic dystrophy, 8 normals, and 10 disease controls with Duchenne dystrophy and other disorders. 3-MH excretion was expressed relative to muscle mass as determined by both urinary creatinine and total body potassium ( 40 K method). Absolute 3-MH excretion was decreased in myotonic dystrophy patients but was normal when related to muscle mass. The finding of normal 3-MH excretion in myotonic dystrophy suggests that the muscle wasting in this disorder results from impaired anabolic processes rather than accelerated muscle destruction

  9. Excretion and intestinal absorption of tritiated glutamic acid by carp, Cyprinus Carpio

    International Nuclear Information System (INIS)

    Watabe, Terushia; Kistner, G.

    1986-01-01

    Excretion and intestinal absorption of tritiated glutamic acid by carp was investigated. Approximately 80% of orally administered tritium was excreted at a half life value of 1.4 h and an observed slower excretion of 7 days for the remainder. Tritium incorporated in glutamic acid was efficiently retained at the site of absorption, i.e. intestine, liver, gill, kidney, blood and muscle. A dual marking experiment using tritiated glutamic acid and 14 C-market glutamic acid showed higher excretion of tritium by factors 2.0 to 4.9 than that of 14 C. Tritiated glutamic acid is considered to be mainly incorporated in the citric acid cycle soon after administration and the release of tritium in tritiated water through the cycle is assumed as causing the initial rapid excretion of tritium in carp. The intestinal absorption of glutamic acid was likely to depend on its concentration in the administered solution. The maximum level of absorption is estimated to be 0.1 m mol/0.5 h for one year old carp. The results obtained here would make it possible to estimate the tritium contamination of fish due to tritiated glutamic acid entering the food chain. (orig.)

  10. Improved sensitivity for W-band Gd(III)-Gd(III) and nitroxide-nitroxide DEER measurements with shaped pulses

    Science.gov (United States)

    Bahrenberg, Thorsten; Rosenski, Yael; Carmieli, Raanan; Zibzener, Koby; Qi, Mian; Frydman, Veronica; Godt, Adelheid; Goldfarb, Daniella; Feintuch, Akiva

    2017-10-01

    Chirp and shaped pulses have been recently shown to be highly advantageous for improving sensitivity in DEER (double electron-electron resonance, also called PELDOR) measurements due to their large excitation bandwidth. The implementation of such pulses for pulse EPR has become feasible due to the availability of arbitrary waveform generators (AWG) with high sampling rates to support pulse shaping for pulses with tens of nanoseconds duration. Here we present a setup for obtaining chirp pulses on our home-built W-band (95 GHz) spectrometer and demonstrate its performance on Gd(III)-Gd(III) and nitroxide-nitroxide DEER measurements. We carried out an extensive optimization procedure on two model systems, Gd(III)-PyMTA-spacer-Gd(III)-PyMTA (Gd-PyMTA ruler; zero-field splitting parameter (ZFS) D ∼ 1150 MHz) as well as nitroxide-spacer-nitroxide (nitroxide ruler) to evaluate the applicability of shaped pulses to Gd(III) complexes and nitroxides, which are two important classes of spin labels used in modern DEER/EPR experiments. We applied our findings to ubiquitin, doubly labeled with Gd-DOTA-monoamide (D ∼ 550 MHz) as a model for a system with a small ZFS. Our experiments were focused on the questions (i) what are the best conditions for positioning of the detection frequency, (ii) which pump pulse parameters (bandwidth, positioning in the spectrum, length) yield the best signal-to-noise ratio (SNR) improvements when compared to classical DEER, and (iii) how do the sample's spectral parameters influence the experiment. For the nitroxide ruler, we report an improvement of up to 1.9 in total SNR, while for the Gd-PyMTA ruler the improvement was 3.1-3.4 and for Gd-DOTA-monoamide labeled ubiquitin it was a factor of 1.8. Whereas for the Gd-PyMTA ruler the two setups pump on maximum and observe on maximum gave about the same improvement, for Gd-DOTA-monoamide a significant difference was found. In general the choice of the best set of parameters depends on the D

  11. Synthesis and Characterization of Hollow Magnetic Alloy (GdNi2, Co5Gd Nanospheres Coated with Gd2O3

    Directory of Open Access Journals (Sweden)

    Wang Li

    2014-01-01

    Full Text Available Uniform magnetic hollow nanospheres (GdNi2, Co5Gd coated with Gd2O3 have been successfully prepared on a large scale via a urea-based homogeneous precipitation method using silica (SiO2 spheres as sacrificed templates, followed by subsequent heat treatment. Nitrogen sorption measurements and scanning electron microscope reveal that these hollow-structured magnetic nanospheres have the mesoporous shells that are composed of a large amount of uniform nanoparticles. After reduction treatment, these nanoparticles exhibit superparamagnetism that might have potential applications in medicine. Furthermore, the developed synthesis route may provide an important guidance for the preparation of other multifunctional hollow spherical materials.

  12. Gd-EOB-DTPA-Enhanced MRI for Detection of Liver Metastases from Colorectal Cancer: A Surgeon’s Perspective!

    Directory of Open Access Journals (Sweden)

    Kelly J. Lafaro

    2013-01-01

    Full Text Available Colorectal cancer affects over one million people worldwide annually, with the liver being the most common site of metastatic spread. Adequate resection of hepatic metastases is the only chance for a cure in a subset of patients, and five-year survival increases to 35% with complete resection. Traditionally, computed tomographic imaging (CT was utilized for staging and to evaluate metastases in the liver. Recently, the introduction of hepatobiliary contrast-enhanced magnetic resonance imaging (MRI agents including gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Eovist in the United States, Primovist in Europe, or Gd-EOB-DTPA has proved to be a sensitive method for detection of hepatic metastases. Accurate detection of liver metastases is critical for staging of colorectal cancer as well as preoperative planning.

  13. Giant magnetocaloric effect in Gd5(Si2Ge2 alloy with low purity Gd

    Directory of Open Access Journals (Sweden)

    Cleber Santiago Alves

    2004-12-01

    Full Text Available Gd5(Ge1-xSi x, x < 4 based alloys are potential candidates for magnetic refrigeration in the range ~20 - ~290 K. However, one of the greatest obstacles for the use of that technology in large scale is the utilization of high pure Gd metal (99.99 wt. (% to produce the GdGeSi alloys, since the impurity elements decrease the intensity of the magnetocaloric effect (EMC¹. In this work, we prove that annealing of the Gd5Ge2Si2 can promote remarkable values for the EMC in comparison to those obtained for the alloy with high pure Gd. Also, the as cast alloy and the annealed alloy are not monophasic, but have at least two crystalline phases in their microstructure. Results for X-ray analysis, optical and electronic microscopy and magnetization measurements are reported.

  14. Phase-Transition and Magnetic Moment of the Gd3+ Ion in the Gd2Fe17 Compound

    Institute of Scientific and Technical Information of China (English)

    HAO Yan-Ming; FU Bin; ZHOU Yan; ZHAO Miao

    2009-01-01

    The structure and magnetic phase transitions of the Gd2Fe17 compound are investigated by using a differential thermal/thermogravimetric analyzer, x-ray diffraction, and magnetization measurements. The result shows that there are two phase structures for the Gd2Fe17 compound: the hexagonal Th2Ni17-type structure at high tem-peratures (above 1243℃), and the rhombohedrai Th2Zn17-type structure, respectively. A method to measure the magnetic moments of the Gd-sublattice and the Fe-sublattice in the Gd2Fe17 compound is presented. The moments of the Gd-sublattice and the Fe-sublattice in the Gd2Fe17 compound from 77 to 500 K are measured in this way with a vibrating sample magnetometer. A detailed discussion is presented.

  15. Intracoronary delivery of Gd-DTPA and Gadophrin-2 for determination of myocardial viability with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Y.; Bosmans, H.; Miao, Y.; Bogaert, J.; Dymarkowski, S.; Yu, J.; Baert, A.L.; Marchal, G. [Dept. of Radiology, University Hospitals, Catholic University Leuven (Belgium); Pislaru, C.; Pislaru, S.; Werf, F. van de [Dept. of Cardiology, University Hospitals, Catholic University Leuven (Belgium); Semmler, W. [Inst. fuer Diagnostikforschung GmbH, Berlin (Germany)

    2001-05-01

    The aim of this study was to compare intracoronary (i. c.) administration of Gadophrin-2, a necrosis-avid contrast agent (NACA), and nonspecific agent Gd-DTPA for determination of myocardial viability (MV) in acute myocardial infarction (AMI) with MRI. Reperfused AMI was induced in 12 dogs by transcatheter balloon occlusion of coronary artery. In 6 dogs each, Gd-DTPA at 0.1 mmol/kg or Gadophrin-2 at 0.005 mmol/kg was administered into coronary artery by fast bolus (n = 3) or slow infusion (n = 3). Serial ECG-triggered cardiac MRI of T1-weighted segmented turbo fast low-angle shot (FLASH) sequence was conducted and compared with triphenyltetrazolium chloride (TTC) histochemical staining. The contrast ratio and infarct size were quantified and analysed statistically. No cardiovascular side effects were found with local delivery of both agents. After i. c. administration, Gadophrin-2 induced a strong (CR {>=} 1.78) and persistent ({>=} 10 h) contrast enhancement of infarcted region. The infarct size defined with Gadophrin-2 was almost identical to that with TTC staining throughout the postcontrast period. With a dose 20 times higher, Gd-DTPA also strongly enhanced infarct-to-normal contrast; however, the enhancement diminished with time, i. e. from early strong to later faint enhancement and eventual loss of contrast. The delineated infarct size was also unstable, i. e. from early overestimation to later underestimation and eventual disappearance of the enhanced infarct. In combination with PTCA procedure, i. c. administration of MRI contrast agents may prove useful for post-procedure verification of diagnosis. The NACA-enhanced MRI may serve as an in vivo surrogate of postmortem histochemical staining for determination of MV. Although applicable in clinical setting, cardiac MRI with nonspecific Gd-DTPA is less reliable and should be performed within less than 1 h after contrast. (orig.)

  16. Associations of ambulatory blood pressure with urinary caffeine and caffeine metabolite excretions.

    Science.gov (United States)

    Guessous, Idris; Pruijm, Menno; Ponte, Belén; Ackermann, Daniel; Ehret, Georg; Ansermot, Nicolas; Vuistiner, Philippe; Staessen, Jan; Gu, Yumei; Paccaud, Fred; Mohaupt, Markus; Vogt, Bruno; Pechère-Bertschi, Antoinette; Pechère-Berstchi, Antoinette; Martin, Pierre-Yves; Burnier, Michel; Eap, Chin B; Bochud, Murielle

    2015-03-01

    Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure. © 2014 American Heart Association, Inc.

  17. The production and use of a 148Gd charged particle target in a spectroscopic study of 147Gd

    International Nuclear Information System (INIS)

    Massey, T.N.

    1988-01-01

    This thesis discusses the nuclear structure of 147 Gd elucidated by the neutron pickup reactions (p,d), (d,t) and ( 3 He,α) on the unstable 148 Gd target. The neutron pickup reaction on 148 Gd probes the two-particle-one-hole states by the pickup of neutrons in the shell model orbitals below the N = 82 gap and one-particle states by pickup of neutrons in shell model orbitals above the N = 82 gap. Our experiments will provide information on the location of neutron single-particle energies which can be used for shell-model calculations in the 146 Gd region. The 2-particle-1-hole (2p-1h) states which are probed directly by the neutron transfer reaction in the experiments with the 148 Gd target, will bear indirectly on the energies of one-hole states in 145 Gd. They will also provide information on the strongest single-particle states in 147 Gd because all the single-particle states in the 148 Gd target are partially occupied because of the mixing by the pairing interaction. 107 refs., 23 figs., 20 tabs

  18. Luminescence study of Eu3+ doped GdVO4 nanoparticles: Concentration, particle size, and core/shell effects

    Science.gov (United States)

    Singh, N. Shanta; Ningthoujam, R. S.; Devi, L. Romila; Yaiphaba, N.; Sudarsan, V.; Singh, S. Dorendrajit; Vatsa, R. K.; Tewari, R.

    2008-11-01

    Nanoparticles of GdVO4 doped with Eu3+ and core/shell of GdVO4:Eu3+/GdVO4 are prepared by urea hydrolysis method using ethylene glycol as capping agent as well as reaction medium at 130 °C. Unit cell volume increases when GdVO4 is doped with Eu3+ indicating the substitution of Gd3+ lattice sites by Eu3+. From luminescence study, it is confirmed that there is no particle size effect on emission positions of Eu3+. Optimum luminescence intensity is found to be in 5-10 at. % Eu3+. Above these concentrations, luminescence intensity decreases due to concentration quenching effect. There is an enhancement in luminescence intensity of core/shell nanoparticles. This has been attributed to the reduction in surface inhomogenities of Eu3+ surroundings by bonding to GdVO4 shell. The lifetime for D50 level increases with annealing and core/shell formation.

  19. Magnetic resonance properties of Gd(III)-bound lipid-coated microbubbles and their cavitation fragments.

    Science.gov (United States)

    Feshitan, Jameel A; Boss, Michael A; Borden, Mark A

    2012-10-30

    Gas-filled microbubbles are potentially useful theranostic agents for magnetic resonance imaging-guided focused ultrasound surgery (MRIgFUS). Previously, MRI at 9.4 T was used to measure the contrast properties of lipid-coated microbubbles with gadolinium (Gd(III)) bound to lipid headgroups, which revealed that the longitudinal molar relaxivity (r(1)) increased after microbubble fragmentation. This behavior was attributed to an increase in water proton exchange with the Gd(III)-bound lipid fragments caused by an increase in the lipid headgroup area that accompanied the lipid shell monolayer-to-bilayer transition. In this article, we explore this mechanism by comparing the changes in r(1) and its transverse counterpart, r(2)*, after the fragmentation of microbubbles consisting of Gd(III) bound to two different locations on the lipid monolayer shell: the phosphatidylethanolamine (PE) lipid headgroup region or the distal region of the poly(ethylene glycol) (PEG) brush. Nuclear magnetic resonance (NMR) at 1.5 T was used to measure the contrast properties of the various microbubble constructs because this is the most common field strength used in clinical MRI. Results for the lipid-headgroup-labeled Gd(III) microbubbles revealed that r(1) increased after microbubble fragmentation, whereas r(2)* was unchanged. An analysis of PEG-labeled Gd(III) microbubbles revealed that both r(1) and r(2)* decreased after microbubble fragmentation. Further analysis revealed that the microbubble gas core enhanced the transverse MR signal (T(2)*) in a concentration-dependent manner but minimally affected the longitudinal (T(1)) signal. These results illustrate a new method for the use of NMR to measure the biomembrane packing structure and suggest that two mechanisms, proton-exchange enhancement by lipid membrane relaxation and magnetic field inhomogeneity imposed by the gas/liquid interface, may be used to detect and differentiate Gd(III)-labeled microbubbles and their cavitation

  20. Remarkably enhanced photoluminescence of hexagonal GdPO4·nH2O:Eu with decreasing size

    International Nuclear Information System (INIS)

    Lu Shaozhe; Zhang Jiahua; Zhang Jishen; Zhao Haifeng; Luo Yongshi; Ren Xinguang

    2010-01-01

    The hexagonal rhabdophane-type GdPO 4 hydrate (GdPO 4 ·nH 2 O) was synthesized via a simple hydrothermal process. The size and morphology of the products can be tunable by adjusting the pH of reaction systems through the addition of aqueous NaOH. The nanorods with a width of 50-100 nm and a length of about 1 μm were obtained in the absence of NaOH (pH = 2), while a significant reduction of size (width: ∼ 10 nm, length: ∼ 50 nm) was observed for the product synthesized in the presence of NaOH (pH = 10). Surprisingly, the small-sized product exhibits a remarkably enhanced photoluminescence quantum yield and long excited state lifetime in comparison with those of the large-sized product. This abnormal luminescence phenomenon is discussed and explained. The EDS and XPS measurements revealed the presence of Na + in the small-sized samples. These Na + cations were probably bonded to the surface O 2- dangling bonds, which thus reduces the number of surface defects that usually serve as the nonradiative energy transfer center channels. A considerable reduction of surface defect centers results in the increase of the emission efficiency and excited state lifetime in a small-sized sample. Obviously, the controlled synthesis of rare-earth-doped nanoparticles with a small size, but with relatively strong luminescence, is significant for their applications in the areas of technologies including optoelectronics, sensing and bioimaging.

  1. Urinary excretion of epidermal growth factor and Tamm-Horsfall protein in three rat models with increased renal excretion of urine

    DEFF Research Database (Denmark)

    Thulesen, J; Jørgensen, P E; Torffvit, O

    1997-01-01

    were examined in three groups of rats with increased renal excretion of urine: uninephrectomy, non-osmotic polyuria and diabetic osmotic polyuria. Twenty-four hour urine samples were obtained after 7, 14 and 21 days. The urinary volume per kidney was doubled in uninephrectomy when compared to controls....... There was a seven-fold increase in urinary volume in rats with non-osmotic polyuria and diabetic osmotic polyuria, as compared to controls. Uninephrectomy, non-osmotic polyuria and diabetes all affected the urinary excretion of EGF and THP differently. The EGF excretion in uninephrectomized rats was 60......-80% of that of the controls, whereas THP excretion was unchanged, indicating that EGF excretion varied with renal tissue mass. Non-osmotic polyuria caused a five-fold increase in THP excretion but no change in EGF excretion. THP excretion in the diabetic rats was increased three-fold after 21 days when compared to controls...

  2. Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease

    International Nuclear Information System (INIS)

    Ding, Ying; Rao, Sheng-Xiang; Meng, Tao; Chen, Caizhong; Li, Renchen; Zeng, Meng-Su

    2014-01-01

    This study evaluates the value of Gd-EOB-DTPA-enhanced MRI for diagnosis and staging of non-alcoholic fatty liver disease (NAFLD) in an animal model by T 1 relaxation time measurement. Thirty-four rabbits were divided into the control group (n = 10) and NAFLD group, which was split into four groups (n = 6) with a high-fat diet for an interval of 3 weeks. A dual flip angle was performed before and at the hepatobiliary phase (HBP). T 1 relaxation times of the liver parenchyma and the decrease rate (∇%) were calculated. Histological findings according to semi-quantitative scoring of steatosis, activity and fibrosis were the standard of reference. HBP and ∇% T 1 relaxation time measurement showed significant differences between normal and NAFLD groups, between non-alcoholic steatohepatitis (NASH) and NAFLD without NASH (p = 0.000-0.049), between fibrosis groups (p = 0.000-0.019), but no difference between F1 and F2 (p = 0.834). The areas under the receiver operating characteristic curves (AUCs) of T 1 relaxation time for HBP and ∇% were 0.86-0.93 for the selection of NASH and activity score ≥2, and 0.86-0.95 for the selection of F ≥ 1, 2, 3. No significant difference was found for diagnostic performance between HBP and ∇% T 1 relaxation time. HBP T 1 relaxation time measurement of Gd-EOB-DTPA-enhanced MRI was useful to evaluate NAFLD according to the SAF score. HBP T 1 relaxation time measurement was as accurate as ∇% T 1 relaxation time. (orig.)

  3. Correlation between structural, electrical and magnetic properties of GdMnO{sub 3} bulk ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Samantaray, S. [Institute of Materials Science, Planetarium Building, Bhubaneswar 751013, Odisha (India); Mishra, D.K. [Department of Physics, Institute of Technical Education and Research, S ‘O’ A University, Bhubaneswar 751030, Odisha (India); Pradhan, S.K. [Institute of Materials Science, Planetarium Building, Bhubaneswar 751013, Odisha (India); Mishra, P.; Sekhar, B.R. [Institue of Physics, Sachivalaya Marg, Bhubaneswar, Odisha (India); Behera, Debdhyan [Advanced Materials Technology Department, CSIR-Institute of Minerals and Materials Technology, Bhubaneswar 751013, Odisha (India); Rout, P.P.; Das, S.K. [Institute of Materials Science, Planetarium Building, Bhubaneswar 751013, Odisha (India); Sahu, D.R. [School of Physics, University of the Witwatersrand, Johannesburg (South Africa); Roul, B.K., E-mail: ims@iopb.res.in [Institute of Materials Science, Planetarium Building, Bhubaneswar 751013, Odisha (India)

    2013-08-15

    This paper reports the effect of sintering temperature on ferroelectric properties of GdMnO{sub 3} (GMO) bulk ceramics at room temperature prepared by the conventional solid state reaction route following slow step sintering schedule. Ferroelectric hysteresis loop as well as sharp dielectric anomaly in pure (99.999%) GMO sintered ceramics has been clearly observed. Samples sintered at 1350 °C become orthorhombic with Pbnm space group and showed frequency independent sharp dielectric anomalies at 373 K and a square type of novel ferroelectric hysteresis loop was observed at room temperature. Interestingly, dielectric anomalies and ferroelectric behavior were observed to be dependent upon sintering temperature of GdMnO{sub 3}. Room temperature dielectric constant (ε{sub r}) value at different frequencies is observed to be abnormally high. The magnetic field and temperature dependent magnetization show antiferromagnetic behavior at 40 K for both 1350 °C and 1700 °C sintered GMO. Present findings showed the possibility of application of GdMnO{sub 3} at room temperature as multifunctional materials. - Highlights: • Preparation of single-phasic polycrystalline GdMnO{sub 3} sample by the solid state sintering route. • Observation of square type P–E hysteresis loop with higher saturation and remnant polarization. • Observation of antiferromagnetic behavior at 40 K in polycrystalline GdMnO{sub 3}. • Possibility of room temperature application of GdMnO{sub 3} as multifunctional material.

  4. Interpretation of uranium and thorium excretion data taking into account excretion data caused by natural sources

    International Nuclear Information System (INIS)

    Sahre, P.; Schoenmuth, Th.; Helling, K.

    2000-01-01

    At the Nuclear Engineering and Analytics Inc. Rossendorf near Dresden (Germany) occupationally exposed persons are working with Uranium and Thorium. In accordance with German guides urine and faecal analysis is carried out. But for the interpretation the data in terms of dose or intake it is important to have knowledge about the portion of the activity measured caused by natural sources. For this reason 16 occupationally exposed persons who did not have any history of occupational exposure to Thorium or Uranium have been checked concerning the excretion data since 1994. The excretion data in mBq per day for all persons covers the following ranges: Faeces: U-234 1 to 310 mBq/d, U-235 0.2 to 3.7 mBq/d, U-238 1.3 to 72 mBq/d. Th-228 7 to 89 mBq/d, Th-230 0.7 to 19 mBq/d, Th-232 0.7 to 16 mBq/d. Urine: all values below the detection limits of about 1 mBq/l. The large variation results from differences between the individual excretion rates but also from the variation of the excretion rate of one person. For example, the U-234-faecal excretion of one person reaches from 77 to 310 mBq per day. In the paper the faecal excretion for some individuals in dependence on the time are given. These excretion date caused by natural sources are taken into account by interpreting faecal excretion data of occupationally exposed persons working with Uranium or Thorium. If the measured faecal excretion per day is within the range caused by natural sources no interpretation will be done. By exceeding these values additional faeces and urine samples will be collected and measured. In dependence on these additional results intake and dose will be assessed some times by using lung counter or whole body counter measuring results. In the paper some examples are described. (author)

  5. Magnetic and ferroelectric characteristics of Gd 3 + and Ti 4 + co ...

    Indian Academy of Sciences (India)

    The crystallographicsite occupancies of Gd and Ti were confirmed by Rietveld refinement of XRD data,Mössbauer spectroscopy and magnetization measurements. An enhancement in ferromagnetic properties along with moderate ferroelectricproperties have been observed after co-doping. There was an increasing trend in ...

  6. Acidosis and Urinary Calcium Excretion

    DEFF Research Database (Denmark)

    Alexander, R Todd; Cordat, Emmanuelle; Chambrey, Régine

    2016-01-01

    Metabolic acidosis is associated with increased urinary calcium excretion and related sequelae, including nephrocalcinosis and nephrolithiasis. The increased urinary calcium excretion induced by metabolic acidosis predominantly results from increased mobilization of calcium out of bone and inhibi...

  7. Radiation characteristics of GD-2 fuel

    International Nuclear Information System (INIS)

    Chrapciak, V.

    2008-01-01

    The assembly WWER-440 type Gd-2 has radial profile of enrichment and has 6 pins with Gd 2 O 3 . The maximal enrichment is 4.4%. Some analyses are done for assembly with flat enrichment (4.4%) and without Gd 2 O 3 . In this article are compared some characteristics (decay heat, some nuclide concentration, photon and gamma sources) for real Gd-2 assembly and for flat 4.4% assembly. The TRITON module (in SCALE 5.1) was used. (Author)

  8. Does Gd-DTPA help in separating tumor from syrinx or cyst in the spinal cord

    International Nuclear Information System (INIS)

    Slasky, B.S.; Niendorf, H.P.; Steiner, R.E.; Bydder, G.M.; Young, I.R.

    1987-01-01

    There is some difficulty in differentiating among syringomyelia, syringomyelia in association with tumor, and cystic tumor in the spinal cord with MR imaging. The role of the paramagnetic contrast agent Gd-DTPA in evaluating this problem was studied in 16 patients. Contrast enhancement was observed in all 12 patients with histologically proved tumors. Enhancement was marked in eight cases, moderate in two cases, and mild in two cases. Compared to the unenhanced images, the images obtained after Gd-DTPA administration delineated more clearly and accurately the exact location and extent of tumor in cord cavitation. This information was extremely helpful in biopsy, definitive surgery, and radiation therapy

  9. Evaluation of Gd and Gd159 as new approaches for cancer treatment

    International Nuclear Information System (INIS)

    Galvao, I.; Neves, M.J.

    2011-01-01

    Metal compounds have shown many biological activities and have been successfully used as anticancer agents such cisplatin. Actually gadolinium (Gd) complexed with a porphyrin Motexafin (MGd) has been investigated as redox-active compound for treatment of cancer. 1 59G d decays by beta emission with an energy of 970 keV and half-life of 18.59 hours. The de-excitation can be via gamma ray and internal conversion electron emission followed by auger electrons and x rays. Considering all of this 1 59G d could be a interesting radionuclide to be as a radio therapeutical agent. The aims of this works were to evaluate the cytotoxicity of Gd and 1 59G d on malignant brain tumors such as glioblastoma multiform, the most frequent brain tumors which has a very poor prognosis. For this purpose, it was used human glioblastoma cell lines T98 (mutant p53) and U87 (wild-type p53) to investigate the cytotoxicity of gadolinium on cell metabolism by MTT assay and also morphological changes, chromatin condensation by DAPI assay and ROS generation. Gadolinium was able to decrease cell viability, the cells presented morphological changes like round shapes and blebs formation after cell treatment with 5x10 -6 M of Gd. Nuclear changing and ROS generation occurred in a dose dependent way indicating the cytotoxic effect of Gd. Treatment with 1 59G d increased all of changes observed with treatment with Gd. These results state for an additive effect of metal toxicity and radioactivity inducing ROS generation as the main mechanism of anti tumoral action of 1 59G d. The results obtained indicated that the radioactive analogues of Gd have increased cytotoxic effects and gadolinium can be a metal of choice for development of new drugs for cancer treatment. (author)

  10. Synthesis and characterization of a porphyrazine-Gd(III) MRI contrast agent and in vivo imaging of a breast cancer xenograft model.

    Science.gov (United States)

    Trivedi, Evan R; Ma, Zhidong; Waters, Emily A; Macrenaris, Keith W; Subramanian, Rohit; Barrett, Anthony G M; Meade, Thomas J; Hoffman, Brian M

    2014-01-01

    Porphyrazines (Pz), or tetraazaporphyrins, are being studied for their potential use in detection and treatment of cancer. Here, an amphiphilic Cu-Pz-Gd(III) conjugate has been prepared via azide-alkyne Huisgen cycloaddition or 'click' chemistry between an azide functionalized Pz and alkyne functionalized DOTA-Gd(III) analog for use as an MRI contrast agent. This agent, Cu-Pz-Gd(III), is synthesized in good yield and exhibits solution-phase ionic relaxivity (r1  = 11.5 mM(-1) s(-1)) that is approximately four times higher than that of a clinically used monomeric Gd(III) contrast agent, DOTA-Gd(III). Breast tumor cells (MDA-MB-231) associate with Cu-Pz-Gd(III) in vitro, where significant contrast enhancement (9.336 ± 0.335 contrast-to-noise ratio) is observed in phantom cell pellet MR images. This novel contrast agent was administered in vivo to an orthotopic breast tumor model in athymic nude mice and MR images were collected. The average T1 of tumor regions in mice treated with 50 mg kg(-1) Cu-Pz-Gd(III) decreased relative to saline-treated controls. Furthermore, the decrease in T1 was persistent relative to mice treated with the monomeric Gd(III) contrast agent. An ex vivo biodistribution study confirmed that Cu-Pz-Gd(III) accumulates in the tumors and is rapidly cleared, primarily through the kidneys. Differential accumulation and T1 enhancement by Cu-Pz-Gd(III) in the tumor's core relative to the periphery offer preliminary evidence that this agent would find application in the imaging of necrotic tissue. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Gd-DTPA-enhanced lesions in the brain of patients with acute optic neuritis

    DEFF Research Database (Denmark)

    Christiansen, P; Frederiksen, J L; Henriksen, O

    1992-01-01

    The cerebral hemispheres of 19 patients with acute monosymptomatic optic neuritis (AMON) were investigated using magnetic resonance imaging (MRI) and Gadolinium-DTPA (Gd-DTPA). Using T1-weighted and T2-weighted imaging sequences it was disclosed that 14 of 19 patients had lesions...

  12. UV-visible light photocatalytic properties of NaYF4:(Gd, Si)/TiO2 composites

    Science.gov (United States)

    Mavengere, Shielah; Kim, Jung-Sik

    2018-06-01

    In this study, a new novel composite photocatalyst of NaYF4:(Gd, Si)/TiO2 phosphor has been synthesized by two step method of solution combustion and sol-gel. The photocatalyst powders were characterized by X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), UV-vis spectroscopy and photoluminescence (PL) spectroscopy. Raman spectroscopy confirmed the anatase TiO2 phase which remarkably increased with existence of yttrium silicate compounds between 800 cm-1 and 900 cm-1. Double-addition of Gd3+-Si4+ ions in NaYF4 host introduced sub-energy band levels with intense absorption in the ultraviolet (UV) light region. Photocatalytic activity was examined by exposing methylene blue (MB) solutions mixed with photocatalyst powders to 254 nm UV-C fluorescent lamp and 200 W visible lights. The UV and visible photocatalytic reactivity of the NaYF4:(Gd, 1% Si)/TiO2 phosphor composites showed enhanced MB degradation efficiency. The coating of NaYF4:(Gd, 1% Si) phosphor with TiO2 nanoparticles creates energy band bending at the phosphor/TiO2 interfaces. Thus, these composites exhibited enhanced absorption of UV/visible light and the separation of electron and hole pairs for efficient photocatalysis.

  13. GdF Suez, the real energy champion;GdF Suez, le vrai champion de l'energie

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, L.

    2010-09-15

    During summer 2010, France discovered that she owned a second energy giant, GdF Suez, ranked number two as a power producer just behind EdF, but world number one in the energy domain thanks to the taking over of International Power (UK) in 2010. Until now, GdF Suez and EdF were confronting with each other in a fair game, keeping their respective seizure on their historical monopolies, gas for GdF Suez and electricity for EdF. From now onward the two giants have started an open fight on all markets, with the exception of nuclear energy for which the French government continues to favour EdF. This paper recalls the main steps of the last 15 years of GdF Suez progress, from the Suez investment bank in 1995 to the merger with GdF in 2008 and the acquisition of International Power in 2010. Then it makes a comparative portrait of both GdF Suez and EdF energy groups with their respective advantages and, finally, it ends with an interview of G. Mestrallet, president of GdF Suez who explains the strategy of his group. (J.S.)

  14. Pulsed laser-deposited nanocrystalline GdB{sub 6} thin films on W and Re as field emitters

    Energy Technology Data Exchange (ETDEWEB)

    Suryawanshi, Sachin R.; More, Mahendra A. [Savitribai Phule Pune University, Department of Physics, Centre for Advanced Studies in Materials Science and Condensed Matter Physics, Pune (India); Singh, Anil K.; Sinha, Sucharita [Bhabha Atomic Research Centre, Laser and Plasma Technology Division, Trombay, Mumbai (India); Phase, Deodatta M. [UGC-DAE Consortium for Scientific Research Indore Centre, Indore (India); Late, Dattatray J. [CSIR-National Chemical Laboratory, Physical and Materials Chemistry Division, Pune (India)

    2016-10-15

    Gadolinium hexaboride (GdB{sub 6}) nanocrystalline thin films were grown on tungsten (W), rhenium (Re) tips and foil substrates using optimized pulsed laser deposition (PLD) technique. The X-ray diffraction analysis reveals formation of pure, crystalline cubic phase of GdB{sub 6} on W and Re substrates, under the prevailing PLD conditions. The field emission (FE) studies of GdB{sub 6}/W and GdB{sub 6}/Re emitters were performed in a planar diode configuration at the base pressure ∝10{sup -8} mbar. The GdB{sub 6}/W and GdB{sub 6}/Re tip emitters deliver high emission current densities of ∝1.4 and 0.811 mA/cm{sup 2} at an applied field of ∝6.0 and 7.0 V/μm, respectively. The Fowler-Nordheim (F-N) plots were found to be nearly linear showing metallic nature of the emitters. The noticeably high values of field enhancement factor (β) estimated using the slopes of the F-N plots indicate that the PLD GdB{sub 6} coating on W and Re substrates comprises of high-aspect-ratio nanostructures. Interestingly, the GdB{sub 6}/W and GdB{sub 6}/Re planar emitters exhibit excellent current stability at the preset values over a long-term operation, as compared to the tip emitters. Furthermore, the values of workfunction of the GdB{sub 6}/W and GdB6/Re emitters, experimentally measured using ultraviolet photoelectron spectroscopy, are found to be same, ∝1.6 ± 0.1 eV. Despite possessing same workfunction value, the FE characteristics of the GdB{sub 6}/W emitter are markedly different from that of GdB{sub 6}/Re emitter, which can be attributed to the growth of GdB{sub 6} films on W and Re substrates. (orig.)

  15. The role of Gd-enhanced three-dimensional MRI fast low-angle shot (FLASH) in the evaluation of symptomatic lumbosacral nerve roots

    Energy Technology Data Exchange (ETDEWEB)

    Kikkawa, Ichiro; Sugimoto, Hideharu; Saita, Kazuo; Ookami, Hitoshi; Nakama, Sueo; Hoshino, Yuichi [Jichi Medical School, Minamikawachi, Tochigi (Japan)

    2001-07-01

    In the field of lumbar spine disorders, three-dimensional (3-D) magnetic resonance imaging (MRI) can clearly depict a lumbar nerve root from the distal region to the dorsal root ganglion. In this study, we used a gadoliniumdiethylenetriaminepentaacetic acid (Gd-DTPA) enhanced-three-dimensional (3-D) fast low-angle shot (FLASH) sequence when examining lumbosacral disorders. The subjects were 33 patients (14 men and 19 women) in whom lumbosacral neural compression had been diagnosed clinically. Twenty-one patients had lumbar disc herniation, 11 had lumbar spinal stenosis, and 1 had lumbar radiculopathy caused by rheumatoid arthritis. Five subjects with low back pain were also studied as a control group. In all patients and in all 5 of the controls, the dorsal root ganglion of every root was enhanced clearly. There was no root enhancement in the 5 controls. Enhancement of the symptomatic nerve roots, caused by compression, was found in 11 of the 33 patients. All 11 patients had rediculopathy, and muscle weakness was more frequent in patients with enhanced nerve roots than in those without enhancement. There was no enhancement of the cauda equina, even in the patients with cauda syndrome. The enhancement effect may reflect some pathological condition of the compressed nerve root and needs to be studied further. (author)

  16. The role of Gd-enhanced three-dimensional MRI fast low-angle shot (FLASH) in the evaluation of symptomatic lumbosacral nerve roots

    International Nuclear Information System (INIS)

    Kikkawa, Ichiro; Sugimoto, Hideharu; Saita, Kazuo; Ookami, Hitoshi; Nakama, Sueo; Hoshino, Yuichi

    2001-01-01

    In the field of lumbar spine disorders, three-dimensional (3-D) magnetic resonance imaging (MRI) can clearly depict a lumbar nerve root from the distal region to the dorsal root ganglion. In this study, we used a gadoliniumdiethylenetriaminepentaacetic acid (Gd-DTPA) enhanced-three-dimensional (3-D) fast low-angle shot (FLASH) sequence when examining lumbosacral disorders. The subjects were 33 patients (14 men and 19 women) in whom lumbosacral neural compression had been diagnosed clinically. Twenty-one patients had lumbar disc herniation, 11 had lumbar spinal stenosis, and 1 had lumbar radiculopathy caused by rheumatoid arthritis. Five subjects with low back pain were also studied as a control group. In all patients and in all 5 of the controls, the dorsal root ganglion of every root was enhanced clearly. There was no root enhancement in the 5 controls. Enhancement of the symptomatic nerve roots, caused by compression, was found in 11 of the 33 patients. All 11 patients had rediculopathy, and muscle weakness was more frequent in patients with enhanced nerve roots than in those without enhancement. There was no enhancement of the cauda equina, even in the patients with cauda syndrome. The enhancement effect may reflect some pathological condition of the compressed nerve root and needs to be studied further. (author)

  17. Transfer of plutonium across the human gut and its urinary excretion

    International Nuclear Information System (INIS)

    Popplewell, D.S.; Ham, G.J.; McCarthy, W.; Lands, C.

    1994-01-01

    The gastrointestinal absorption of 244 Pu(IV) has been measured in three male adult volunteers. The plutonium was in citrate solution and was taken with food. The work was carried out in two stages. The first stage measured urinary plutonium excretion up to 8 or 9 d after the oral intake. The second stage commenced about six months later with an intravenous injection of plutonium citrate and measurements of the urinary plutonium excretion. Results from the two routes of intake were used to calculate the fractional absorption (f 1 ) of ingested plutonium. The f 1 values were in the range (2-9) x 10 -4 . In theory it should be possible to measure the plutonium in the volunteers' urine throughout their lives. Measurements are continuing and the results show the excretion pattern up to nearly 2 y for one subject, and 6 months for the other two volunteers. (author)

  18. Sequential MR images of uterus after Gd-DTPA injection

    International Nuclear Information System (INIS)

    Okada, Susumu; Kato, Tomoyasu; Yamada, Keiko; Sawano, Seishi; Yamashita, Takashi; Hirai, Yasuo; Hasumi, Katsuhiko

    1993-01-01

    To investigate the sequential changes in signal intensity (SI) of normal and abnormal uteri, T1-weighted images were taken repeatedly after the injection of Gd-diethylenetriaminepentaacetic acid (DTPA). Six volunteers and 19 patients with known uterine body malignancy (18 carcinomas, one carcinosarcoma) were examined. The results in volunteers were as follows. In the secretory phase, SI of the endometrium was stronger in the late images than in the early ones, whereas in the proliferative phase, SI was stronger in the early images. SI of the myometrium decreased rapidly and there were no differences in SI between menstrual phases. In 17 of 18 endometrial carcinomas, the tumors showed hypointensity relative to the myometrium, and the contrast between the tumor and the myometrium was better in the early images. In the remaining two cases, the tumor showed hyperintensity and the contrast was better in the late images. After the injection of Gd-DTPA, the endometrium appeared differently according to the menstrual cycle in normal volunteers, and the appearance of uterine structures and endometrial malignant tumors changed sequentially. These findings must be kept in mind when evaluating uterine diseases by Gd-DTPA enhanced MRI. (author)

  19. T1-T2 dual-modal MRI of brain gliomas using PEGylated Gd-doped iron oxide nanoparticles.

    Science.gov (United States)

    Xiao, Ning; Gu, Wei; Wang, Hao; Deng, Yunlong; Shi, Xin; Ye, Ling

    2014-03-01

    To overcome the negative contrast limitations of iron oxide-based contrast agents and to improve the biocompatibility of Gd-chelate contrast agents, PEGylated Gd-doped iron oxide (PEG-GdIO) NPs as a T1-T2 dual-modal contrast agent were synthesized by the polyol method. The transverse relaxivity (r2) and longitudinal relaxivity (r1) of PEG-GdIO were determined to be 66.9 and 65.9 mM(-1) s(-1), respectively. The high r1 value and low r2/r1 ratio make PEG-GdIO NPs suitable as a T1-T2 dual-modal contrast agent. The in vivo MRI demonstrated a brighter contrast enhancement in T1-weighted image and a simultaneous darken effect in T2-weighted MR image compared to the pre-contrast image in the region of glioma. Furthermore, the biocompatibility of PEG-GdIO NPs was confirmed by the in vitro MTT cytotoxicity and in vivo histological analyses (H&E). Therefore, PEG-GdIO NPs hold great potential in T1-T2 dual-modal imaging for the diagnosis of brain glioma. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Determination of Gd concentration profile in UO{sub 2}–Gd{sub 2}O{sub 3} fuel pellets

    Energy Technology Data Exchange (ETDEWEB)

    Tobia, D., E-mail: dina.tobia@cab.cnea.gov.ar [Laboratorio de Resonancias Magnéticas, Centro Atómico Bariloche – CNEA and CONICET, 8400 S.C. de Bariloche (Argentina); Winkler, E.L.; Milano, J.; Butera, A. [Laboratorio de Resonancias Magnéticas, Centro Atómico Bariloche – CNEA and CONICET, 8400 S.C. de Bariloche (Argentina); Kempf, R. [División Caracterización de Combustibles Avanzados, Gerencia Ciclo Combustible Nuclear, Centro Atómico Constituyentes – CNEA, 1650 San Martín, Pcia. de Buenos Aires (Argentina); Bianchi, L.; Kaufmann, F. [Departamento de Combustibles Avanzados, Gerencia Ciclo Combustible Nuclear, Centro Atómico Constituyentes – CNEA, 1650 San Martín, Pcia. de Buenos Aires (Argentina)

    2014-08-01

    A transversal mapping of the Gd concentration was measured in UO{sub 2}–Gd{sub 2}O{sub 3} nuclear fuel pellets by electron paramagnetic resonance spectroscopy (EPR). The quantification was made from the comparison with a Gd{sub 2}O{sub 3} reference sample. The nominal concentration in the pellets is UO{sub 2}: 7.5% Gd{sub 2}O{sub 3}. A concentration gradient was found, which indicates that the Gd{sub 2}O{sub 3} amount diminishes towards the edges of the pellets. The concentration varies from (9.3 ± 0.5)% in the center to (5.8 ± 0.3)% in one of the edges. The method was found to be particularly suitable for the precise mapping of the distribution of Gd{sup 3+} ions in the UO{sub 2} matrix.

  1. Transintestinal cholesterol excretion in humans

    NARCIS (Netherlands)

    Reeskamp, Laurens F.; Meessen, Emma C. E.; Groen, Albert K.

    2018-01-01

    Purpose of review To discuss recent insights into the measurement and cellular basis of transintestinal cholesterol excretion (TICE) in humans and to explore TICE as a therapeutic target for increasing reverse cholesterol transport. Recent findings TICE is the net effect of cholesterol excretion by

  2. Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Ying; Rao, Sheng-Xiang; Meng, Tao; Chen, Caizhong; Li, Renchen; Zeng, Meng-Su [Zhongshan/Hospital of Fudan University, Department of Radiology, Shanghai (China)

    2014-04-15

    This study evaluates the value of Gd-EOB-DTPA-enhanced MRI for diagnosis and staging of non-alcoholic fatty liver disease (NAFLD) in an animal model by T{sub 1} relaxation time measurement. Thirty-four rabbits were divided into the control group (n = 10) and NAFLD group, which was split into four groups (n = 6) with a high-fat diet for an interval of 3 weeks. A dual flip angle was performed before and at the hepatobiliary phase (HBP). T{sub 1} relaxation times of the liver parenchyma and the decrease rate (∇%) were calculated. Histological findings according to semi-quantitative scoring of steatosis, activity and fibrosis were the standard of reference. HBP and ∇% T{sub 1} relaxation time measurement showed significant differences between normal and NAFLD groups, between non-alcoholic steatohepatitis (NASH) and NAFLD without NASH (p = 0.000-0.049), between fibrosis groups (p = 0.000-0.019), but no difference between F1 and F2 (p = 0.834). The areas under the receiver operating characteristic curves (AUCs) of T{sub 1} relaxation time for HBP and ∇% were 0.86-0.93 for the selection of NASH and activity score ≥2, and 0.86-0.95 for the selection of F ≥ 1, 2, 3. No significant difference was found for diagnostic performance between HBP and ∇% T{sub 1} relaxation time. HBP T{sub 1} relaxation time measurement of Gd-EOB-DTPA-enhanced MRI was useful to evaluate NAFLD according to the SAF score. HBP T{sub 1} relaxation time measurement was as accurate as ∇% T{sub 1} relaxation time. (orig.)

  3. Synthesis, characterization and thermal behavior: Gd(NO3)3.6H2O to Gd2O3

    International Nuclear Information System (INIS)

    Ghonge, Darshana K.; Sheelvantra, Smita S.; Kalekar, Bhupesh B.; Raje, Naina

    2015-01-01

    Gadolinium oxide finds its application in nuclear as well as medical industry. It has been prepared from the thermal decomposition of gadolinium nitrate hexahydrate. Surface area of the synthesized compound was measured as 19 m 2 /g. EDS data shows only the presence of gadolinium and oxygen in the synthesized compound with the Gd to O ratio as calculated for Gd 2 O 3 , suggests the formation of pure Gd 2 O 3 . XRD analysis confirms the formation of pure cubic phase Gd 2 O 3 . In the absence of any report on the thermal behavior of GdNH, present studies have been carried out to understand the decomposition mechanism using simultaneous TG - DTA - EGA measurements

  4. Enhanced conductivity in pulsed laser deposited Ce0.9Gd0.1O2−δ/SrTiO3 heterostructures

    DEFF Research Database (Denmark)

    Kant, K. Mohan; Esposito, Vincenzo; Pryds, Nini

    2010-01-01

    Significant enhancement in the electrical conductivity of Ce0.9Gd0.1O2−δ (CGO) thin films (250 and 500 nm) deposited on MgO(001) substrate is observed by introducing ∼ 50 nm thin SrTiO3 buffer layer film. Introduction of the buffer layer is found to form epitaxial films, leading to minimal grain...... boundary network that results in a free conduction path with near-zero blocking effects perpendicular to current flow. The in-plane conductivity measurements confirm increase in conductivity with increase in compressive strain on CGO films. © 2010 American Institute of Physics...

  5. Role of Gd-DTPA enhanced fat-suppression MR imaging on ovarian tumors

    International Nuclear Information System (INIS)

    Kang, Heoung Keun; Moon, Woong Jae; Seo, Jeong Jin; Kim, Jae Kyu; Park, Jin Gyoon; Choi, Ho Sun

    1995-01-01

    To determine the value of Gd-DTPA enhanced fat-suppression (GEFS) MR imaging in the characterization and differentiation of benign from malignant ovarian tumors. MRI findings of thirty-seven patients with surgically proved 44 ovarian tumors (30 benign, 14 malignant) were studied retrospectively. MR imaging with conventional spin echo (CSE; T1-weighted image TR/TE 450/20, T2-weighted image TR/TE 3500/30, 90) and GEFS were performed with a 1.5T GE signa. MRI findings of tumors including cystic or solid, wall and septal thickness, necrosis, invasion to adjacent organ, ascites and lymphadenopathy were assessed separately by using CSE and GEFS images, and then tumors were characterized as benign or malignant. Compared with CSE image, GEFS MR image showed better visualization of solid component in 5 malignant lesions, wall thickness in 5 malignant and 1 benign lesions, septal thickness in 3 malignant and 1 benign lesions, necrosis in 1 malignant lesion, and adjacent soft tissue invasion in 5 malignant lesions. Correct characterization of malignant tumors was increased from 71% on CSE image to 93% on GEFS image. However, correct characterization of benign tumors was 93% on both images. GEFS MR imaging could be useful for characterization of ovarian tumors, especially in malignant cases, and employed for differentiation of benign from malignant tumors

  6. Synthesis and characterization of Gd-doped magnetite nanoparticles

    International Nuclear Information System (INIS)

    Zhang, Honghu; Malik, Vikash; Mallapragada, Surya; Akinc, Mufit

    2017-01-01

    Synthesis of magnetite nanoparticles has attracted increasing interest due to their importance in biomedical and technological applications. Tunable magnetic properties of magnetite nanoparticles to meet specific requirements will greatly expand the spectrum of applications. Tremendous efforts have been devoted to studying and controlling the size, shape and magnetic properties of magnetite nanoparticles. Here we investigate gadolinium (Gd) doping to influence the growth process as well as magnetic properties of magnetite nanocrystals via a simple co-precipitation method under mild conditions in aqueous media. Gd doping was found to affect the growth process leading to synthesis of controllable particle sizes under the conditions tested (0–10 at% Gd"3"+). Typically, undoped and 5 at% Gd-doped magnetite nanoparticles were found to have crystal sizes of about 18 and 44 nm, respectively, supported by X-ray diffraction and transmission electron microscopy. Our results showed that Gd-doped nanoparticles retained the magnetite crystal structure, with Gd"3"+ randomly incorporated in the crystal lattice, probably in the octahedral sites. The composition of 5 at% Gd-doped magnetite was Fe_(_3_−_x_)Gd_xO_4 (x=0.085±0.002), as determined by inductively coupled plasma mass spectrometry. 5 at% Gd-doped nanoparticles exhibited ferrimagnetic properties with small coercivity (~65 Oe) and slightly decreased magnetization at 260 K in contrast to the undoped, superparamagnetic magnetite nanoparticles. Templation by the bacterial biomineralization protein Mms6 did not appear to affect the growth of the Gd-doped magnetite particles synthesized by this method. - Highlights: • Gd-doped magnetite nanoparticles are synthesized via aqueous co-precipitation method under mild conditions. • Gd doping affects growth of magnetite nanoparticles leading to tunable particle size. • Gd-doped magnetite nanoparticles exhibit ferrimagnetic properties.

  7. 3D Whole-Heart Coronary MR Angiography at 1.5T in Healthy Volunteers: Comparison between Unenhanced SSFP and Gd-Enhanced FLASH Sequences

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Lee, Sang Min; Hong, Yoo Jin; Kim, Tae Hoon

    2011-01-01

    To validate the optimal cardiac phase and appropriate acquisition window for three-dimensional (3D) whole-heart coronary magnetic resonance angiography (MRA) with a steady-state free precession (SSFP) sequence, and to compare image quality between SSFP and Gd-enhanced fast low-angle shot (FLASH) MR techniques at 1.5 Tesla (T). Thirty healthy volunteers (M:F 25:5; mean age, 35 years; range, 24-54 years) underwent a coronary MRA at 1.5T. 3D whole-heart coronary MRA with an SSFP was performed at three different times: 1) at end-systole with a narrow (120-msec) acquisition window (ESN), 2) mid-diastole with narrow acquisition (MDN); and 3) mid-diastole with wide (170-msec) acquisition (MDW). All volunteers underwent a contrast enhanced coronary MRA after undergoing an unenhanced 3D true fast imaging with steady-state precession (FISP) MRA three times. A contrast enhanced coronary MRA with FLASH was performed during MDN. Visibility of the coronary artery and image quality were evaluated for 11 segments, as suggested by the American Heart Association. Image quality was scored by a five-point scale (1 = not visible to 5 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were evaluated at the proximal coronary arteries. The SSFP sequence rendered higher visibility coronary segments, higher image quality, as well as higher SNR and CNR than the Gd-enhanced FLASH technique at 1.5T (p < 0.05). The visibility of coronary segments, image quality, SNR and CNR in the ESN, MDN and MDW with SSFP sequence did not differ significantly. An SSFP sequence provides an excellent method for the 3D whole-heart coronary MRA at 1.5T. Contrast enhanced coronary MRA using the FLASH sequence does not help improve the visibility of coronary segments, image quality, SNR or CNR on the 3D whole-heart coronary MRA.

  8. Po-210 excretion and radon exposure

    International Nuclear Information System (INIS)

    Breuer, F.; Clemente, G.F.

    1979-01-01

    A mathematical model is given to describe the metabolism of the 210 Po introduced into the systemic compartiments of the human body. The model has been based on the experimental data referred to the 210 Pb- 210 Po intake, excretion and body burden of members of the general italian population. The model fits also very well the experimental data of 210 Pb- 210 Po intake and excretion reported by other authors. The retention function of 210 Po in total body, soft tissue and bone has been evaluated together with the urinary excretion function and the absorbed fraction by ingestion. The model is very valuable to evaluate the lung exposure to Radon decay products on the basis of the 210 Pb- 210 Po urinary excretions

  9. New perspective for GdNCT. Gd-DTPA reaches the nucleus of glioblastoma cells in culture and in vivo

    International Nuclear Information System (INIS)

    Stasio, G. de; Gilbert, B.; Frazer, B.H.

    2000-01-01

    We investigated the prospects of gadolinium as a neutron capture therapy agent by combining three independent techniques to study the uptake of Gd-DTPA in vitro, in cultured glioblastoma cells, and in vivo, in the glioblastoma tissue sections after injection of Gd-DTPA and tumor extraction. We show that gadolinium not only penetrates the plasma membrane of glioblastoma cells grown in culture, but we also observe a statistically significant higher concentration of Gd in the nucleus relative to the cytoplasm. For the in vivo experiments, Gd-DTPA was administered to 6 glioblastoma patients before neurosurgery. The extracted bioptic tissue was then analyzed with spectromictroscopy, showing Gd localized in the nuclei of glioblastoma cells in 5 patients out of the 6 analyzed. (author)

  10. Contribution to the qualification of Gd calculation in PWR reactors

    International Nuclear Information System (INIS)

    Chaucheprat, Patrick.

    1982-06-01

    This thesis presents the state of knowledge on gadolinium and the advantages of its use as burnable poison. A study on the behaviour of gadolinium makes it possible to bring out the essential parameters to which it is sensitive. The most important part of this work is devoted to the measurements by oscillations carried out in Minerve in 1981. The conceiving and implementation of this campaign are reported. The experimental results and the amending factors linked to the interpretation are presented. To complete this study at zero time, it seemed useful to process configurations with fuel clusters of UO 2 - Gd 2 O 3 in order to see the effect of UO 2 - Gd 2 O 3 rods in interaction. To this end, efficiency determinations of UO 2 - Gd 2 O 3 rod clusters were carried out in the Melodie lattice. The second part of this work involves the change in the gadolinium. Two main points are tackled here. The first concerns the determinations by oscillations of ''reconstituted'' samples that are composed of two concentric rings with various 235 U enrichments and gadolinium levels so as to simulate irradiated UO 2 - Gd 2 O 3 fuel. The second point is devoted to the description of the GEDEON experiment. UO 2 - Gd 2 O 3 rods will be irradiated in a 13 x 13 lattice of which the spectrum is representative of that of a PWR. This experiment will take place in the centre of the Melusine reactor at Grenoble [fr

  11. Structural and magnetic properties of Gd-doped ZnO

    KAUST Repository

    Bantounas, Ioannis

    2014-01-01

    We use density functional theory to investigate structural and magnetic properties of Gd doped ZnO, accounting for the impurity 4f states using the GGA + U method. (i) We calculate the binding energy of forming [Gd-Gd] dimers, [VO - GdZn] and [VZn - GdZn] complexes and find that while the formation of [VZn - GdZn] is favourable, [GdZn - GdZn] and [VO - GdZn] complexes are less likely to form. Next, (ii) we investigate the spacial arrangement of two (and three) GdZn impurities in a 3 × 3 × 2 supercell and find that the magnetic impurities are energetically favourable when occupying distant lattice sites. Finally, we study the nature of interactions between the magnetic impurities (iii) for Gd in nearest-neighbour and non-nearest-neighbour Zn sites, (iv) in the presence of Zn or O vacancies, and (v) with and without additional charge carriers. Our results show mainly paramagnetic behaviour. In a few cases, e.g. magnetic impurities occupying in-plane nearest-neighbour zinc sites with n-type carrier doping, weak ferromagnetic coupling is observed. This magnetic ordering is of the order of a few meV and can be easily destroyed by thermal fluctuations. We thus expect Gd:ZnO to show paramagnetic behaviour at temperatures approaching room temperature.

  12. Investigation of Gd compounds using synchrotron radiation

    International Nuclear Information System (INIS)

    Tyszka, B.; Szade, J.; Burian, W.; Skorek, G.; Deniszczyk, J.; Sikora, M.; Zajac, D.; Kapusta, Cz.; Matteucci, M.; Bondino, F.; Zacchigna, M.; Zangrando, M.

    2005-01-01

    The electronic structure of ferromagnetic compound GdTiGe has been investigated using element sensitive methods-X-ray absorption spectroscopy (XAS), X-ray magnetic circular dichroism (XMCD) and resonant inelastic X-ray scattering (RIXS). Additionally, another ferromagnet GdTiSi has been studied using XMCD. XMCD revealed a strong dichroic signal at Gd L 2 and L 3 edges, which can be related to polarisation of Gd 5d band. XAS at Ti L 2,3 edges has exhibited a structure which appeared to be in general agreement with the LAPW calculations. RIXS spectra have shown some resonance features for photon energies close to Ti L 2 and Gd M 5 edges

  13. Improved parenchymal liver enhancement with extended delay on Gd-EOB-DTPA-enhanced MRI in patients with parenchymal liver disease: associated clinical and imaging factors

    International Nuclear Information System (INIS)

    Esterson, Y.B.; Flusberg, M.; Oh, S.; Mazzariol, F.; Rozenblit, A.M.; Chernyak, V.

    2015-01-01

    Aim: To establish the effect of prolonged hepatobiliary phase (HBP) delay time on hepatic enhancement in patients with parenchymal liver disease (PLD). Materials and methods: Gadoxetate disodium (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) examinations with HBP were obtained after 20- (HBP-20) and 30-minute (HBP-30) delays in patients with PLD. For each patient, the Model for End-Stage Liver Disease (MELD) score, total and direct bilirubin, aspartate transaminase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), prothrombin time (PT), and partial thromboplastin time (PTT) were recorded. Signal intensities of the liver, main portal vein, and spleen on pre-contrast, HBP-20, and HBP-30 were documented. Signal intensities were used to calculate liver relative enhancement (LRE), liver–spleen index (LSI), and liver–portal vein index (LPI) for HBP-20 and HBP-30. Improved hepatic enhancement was considered if two or more indices were higher on HBP-30 than HBP-20. A logistic regression model was constructed with improved hepatic enhancement as the outcome. Results: One hundred and twenty-nine patients underwent 142 MRIs. Mean LRE, LSI, and LPI each increased from HBP-20 to HBP-30 (p = 0.004, p < 0.001, and p < 0.001, respectively). Seventy-two point five percent of cases demonstrated improved hepatic enhancement. The odds ratios for improved hepatic enhancement were 0.85 for MELD score (p = 0.02) and 3.2 for the 3 T scanner (p = 0.02), adjusted for age and sex. Conclusion: Increasing HBP delay to 30 minutes improves hepatic enhancement in patients with PLD, particularly if using a 3 T scanner. This effect is attenuated with higher MELD scores. -- Highlights: •Increasing hepatobiliary phase delay improves hepatic enhancement in liver disease. •This effect is enhanced if using a 3T scanner. •This effect is attenuated with higher MELD scores

  14. Renal acid excretion in the domestic fowl.

    Science.gov (United States)

    Long, S; Skadhauge, E

    1983-05-01

    1. In order to assess the role of uricotelism in net renal acid excretion, blood and ureteral urine samples were collected from five hens fed a commercial poultry feed (Diet A) and five hens fed a protein-rich, Na-poor feed (Diet B). All samples were analysed for pH, PCO2, ammonium, phosphate, uric acid and urates (UA + U) and inulin. 2. On Diet A, average pH in venous blood was 7.42, while urinary pH (pHu) ranged from 4.74 to 7.25. At average pHu (6.10), uric acid accounted for 52% of total acid excreted, H2PO4 for 20% and NH4 for 28%. Net acid excretion in ureteral urine was 345 muequiv h-1 kg body weight-1, or 5-10 times that observed in ureotelic vertebrates (amphibians and mammals). 3. The relative contributions of these urinary buffers to net renal acid excretion changed with pHu. Significant negative correlations exist between pHu and both total phosphate and ammonium excretion rates (P less than 0.001). Excretion rates of (UA + U) showed a positive correlation (P less than 0.05) with pHu. 4. Feeding on Diet B revealed the homeostatic power of the avian kidney. Blood pH and PCO2 were not changed relative to values in hens fed the control diet while striking increases in excretion rates of all urinary buffers (except HCO3) were observed. Average pHu fell to 5.12, and the average net renal acid excretion rate doubled.

  15. Organ burdens and excretion rates of inhaled uranium - computations using ICRP model

    International Nuclear Information System (INIS)

    Abani, M.C.; Murthy, K.B.S.; Sunta, C.M.

    1988-01-01

    Uranium being a highly toxic material, proper estimation of the body burden is very important. During manufacture of uranium fuel, it is likely to enter the body by inhalation. By the body burden and excretion measurements, one should be able to assess whether the intake is within the safe limits or not. This is possible if one performs theoretical calculations and estimates the amount of uranium which builds up in the body as a function of time. Similarly theoretical estimates in case of excretion have to be made. For this purpose, a computer programme has been developed to find out organ burdens and excretion rates resulting from exposure to a radioactive nuclide. ICRP-30 lung model has been used and cases of single instantaneous inhalation of 1 ALI as well as inhalation at a steady rate of ALI/365 per day have been considered. Using this programme, results for uranium aerosols of classes D, W and Y and sizes 0.2, 1 and 5 microns are generated by ND computers in tabular as well as graphical forms. These will be useful in conjunction with body burden measurements by direct counting or excretion analysis. (author). 7 tabs., 56 figs

  16. Visualization of Tumor Angiogenesis Using MR Imaging Contrast Agent Gd-DTPA-anti-VEGF Receptor 2 Antibody Conjugate in a Mouse Tumor Model

    International Nuclear Information System (INIS)

    Jun, Hong Young; Yin, Hong Hua; Kim, Sun Hee; Park, Seong Hoon; Kim, Hun Soo; Yoon Kwon Ha Yoon

    2010-01-01

    To visualize tumor angiogenesis using the MRI contrast agent, Gd- DTPA-anti-VEGF receptor 2 antibody conjugate, with a 4.7-Tesla MRI instrument in a mouse model. We designed a tumor angiogenesis-targeting T1 contrast agent that was prepared by the bioconjugation of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) and an anti-vascular endothelial growth factor receptor-2 (VEGFR2) antibody. The specific binding of the agent complex to cells that express VEGFR2 was examined in cultured murine endothelial cells (MS-1 cells) with a 4.7-Tesla magnetic resonance imaging scanner. Angiogenesis-specific T1 enhancement was imaged with the Gd-DTPA-anti-VEGFR2 antibody conjugate using a CT-26 adenocarcinoma tumor model in eight mice. As a control, the use of the Gd-DTPA-anti-rat immunoglobulin G (Gd-DTPA-anti-rat IgG) was imaged with a tumor model in eight mice. Statistical significance was assessed using the Mann-Whitney test. Tumor tissue was examined by immunohistochemical analysis. The Gd-DTPA-anti-VEGFR2 antibody conjugate showed predominant binding to cultured endothelial cells that expressed a high level of VEGFR2. Signal enhancement was approximately three-fold for in vivo T1-weighted MR imaging with the use of the Gd-DTPA-anti-VEGFR2 antibody conjugate as compared with the Gd-DTPA-rat IgG in the mouse tumor model (p < 0.05). VEGFR2 expression in CT-26 tumor vessels was demonstrated using immunohistochemical staining. MR imaging using the Gd-DTPA-anti-VEGFR2 antibody conjugate as a contrast agent is useful in visualizing noninvasively tumor angiogenesis in a murine tumor model

  17. Visualization of Tumor Angiogenesis Using MR Imaging Contrast Agent Gd-DTPA-anti-VEGF Receptor 2 Antibody Conjugate in a Mouse Tumor Model

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Hong Young; Yin, Hong Hua; Kim, Sun Hee; Park, Seong Hoon; Kim, Hun Soo; Yoon Kwon Ha Yoon [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2010-08-15

    To visualize tumor angiogenesis using the MRI contrast agent, Gd- DTPA-anti-VEGF receptor 2 antibody conjugate, with a 4.7-Tesla MRI instrument in a mouse model. We designed a tumor angiogenesis-targeting T1 contrast agent that was prepared by the bioconjugation of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) and an anti-vascular endothelial growth factor receptor-2 (VEGFR2) antibody. The specific binding of the agent complex to cells that express VEGFR2 was examined in cultured murine endothelial cells (MS-1 cells) with a 4.7-Tesla magnetic resonance imaging scanner. Angiogenesis-specific T1 enhancement was imaged with the Gd-DTPA-anti-VEGFR2 antibody conjugate using a CT-26 adenocarcinoma tumor model in eight mice. As a control, the use of the Gd-DTPA-anti-rat immunoglobulin G (Gd-DTPA-anti-rat IgG) was imaged with a tumor model in eight mice. Statistical significance was assessed using the Mann-Whitney test. Tumor tissue was examined by immunohistochemical analysis. The Gd-DTPA-anti-VEGFR2 antibody conjugate showed predominant binding to cultured endothelial cells that expressed a high level of VEGFR2. Signal enhancement was approximately three-fold for in vivo T1-weighted MR imaging with the use of the Gd-DTPA-anti-VEGFR2 antibody conjugate as compared with the Gd-DTPA-rat IgG in the mouse tumor model (p < 0.05). VEGFR2 expression in CT-26 tumor vessels was demonstrated using immunohistochemical staining. MR imaging using the Gd-DTPA-anti-VEGFR2 antibody conjugate as a contrast agent is useful in visualizing noninvasively tumor angiogenesis in a murine tumor model

  18. Comparison of gadolinium polylysine and gadopentetate in contrast enhanced MR imaging of myocardial ischemia-reperfusion in cats

    International Nuclear Information System (INIS)

    Lim, Tae Hwan; Lee, Jung Hee; Lee, Tae Keun; Mun, Chi Woong

    1995-01-01

    To assess the signal enhancement by gadolinium-DTPA-polylysine (Gd-polylysine) as compared to gadopentetate (Gd-DTPA) in MR imaging of heart that have undergone ischemia-reperfusion, and to estimate the extent of myocardial damage covered by the MR signal enhancement. A series of contrast enhanced cardiac MR images were obtained from 17 cats subjected to a 90 minutes of occlusion of the left anterior descending coronary artery (LAD) followed by a 90 minutes of reperfusion. Time courses of changes in the signal intensity (SI) of the ischemic area were measured in Gd-polylysine group (8 cats) and Gd-DTPA group (9 cats). The size of MR signal enhanced area was then compared to the sizes of infarction and the area at risk revealed by TTC histochemical staining. Maximum SIs were obtained at 60 minutes and 30 minutes after injection of the contrast material, respectively for Gd-polylysine group and Gd-DTPA group. Signal enhancement was stronger and persistent for a longer period in Gd-polylysine group than in GD-DTPA group. Sizes of the enhanced are, the infarction, and the area at risk were about 30%, 15%, and 50% of the total left ventricle (LV) area; the difference between the groups was statistically insignificant. Gd-polylysine can be used better for a blood pool marker than Gd-DTPA in MR imaging of myocardial ischemia, due to its strong and persistent signal enhancement. The MR signal enhanced area includes both the infarcted area and a portion of the area at risk

  19. GdF Suez, the real energy champion

    International Nuclear Information System (INIS)

    Dupin, L.

    2010-01-01

    During summer 2010, France discovered that she owned a second energy giant, GdF Suez, ranked number two as a power producer just behind EdF, but world number one in the energy domain thanks to the taking over of International Power (UK) in 2010. Until now, GdF Suez and EdF were confronting with each other in a fair game, keeping their respective seizure on their historical monopolies, gas for GdF Suez and electricity for EdF. From now onward the two giants have started an open fight on all markets, with the exception of nuclear energy for which the French government continues to favour EdF. This paper recalls the main steps of the last 15 years of GdF Suez progress, from the Suez investment bank in 1995 to the merger with GdF in 2008 and the acquisition of International Power in 2010. Then it makes a comparative portrait of both GdF Suez and EdF energy groups with their respective advantages and, finally, it ends with an interview of G. Mestrallet, president of GdF Suez who explains the strategy of his group. (J.S.)

  20. Enhancement of the normal pancreas: comparison of manganese-DPDP and gadolinium chelate

    International Nuclear Information System (INIS)

    Kettritz, U.; Warshauer, D.M.; Brown, E.D.; Schlund, J.F.; Eisenberg, L.B.; Semelka, R.C.

    1996-01-01

    The purpose of this paper was to compare manganese-DPDP (Mn-DPDP) and gadolinium chelate (Gd-DTPA) contrast agents for enhancement of the normal pancreas. A total of 14 patients with focal liver disease underwent Mn-DPDP-and Gd-DTPA-enhanced 1.5 T MR examinations using spoiled gradient-echo (FLASH) technique at two separate times. Contrast agents were injected according to the currently recommended practices; Gd-DTPA was injected as a rapid bolus injection in a dosage of 0.1 mmol/kg, and Mn-DPDP was injected as a slow IV injection in a dosage of 5 μmol/kg. Quantitative region of interest measurements were made in 11 patients, and percent contrast enhancement of the pancreas and pancreas-fat signal-to-noise ratios (SNR) were determined for each agent. Images were also evaluated qualitativley by consensus reading of two investigators and overall scan quality was rated on a scale from 1 (poor) to 4 (very good). Enhancement of the pancreas immediately post Gd-DTPA was significantly higher than 15 min post Mn-DPDP (73.3 vs 36.3%; p=0.003). On postcontrast images the pancreas-fat SNR measruements were 7.7 (i.e., pancreas higher in signal than fat) and -6.1 for Gd-DTPA and Mn-DPDP, respectively, which was significantly different (p<0.001). Image quality was rated as 3.1 and 2.5 for Gd-DTPA- and Mn-DPDP-enhanced images, respectively. The normal pan creas enhances significantly more with Gd-DTPA than with Mn-DPDP administered under the conditions of this study. Overall image quality is also greater on the Gd-DTPA-enhanced images. (orig.)

  1. Iodine excretion in school children in Copenhagen

    DEFF Research Database (Denmark)

    Rasmussen, Lone B.; Kirkegaard-Klitbo, Ditte Marie; Laurberg, Peter

    2016-01-01

    INTRODUCTION: Studies of dietary habits show a high iodine intake in children in Denmark. Iodine excretion in children has not previously been assessed. Iodine excretion in adults is below the recommended threshold, and it is therefore being discussed to increase the fortification level. The main...... objective of this study was to assess iodine excretion in children living in Copenhagen to establish whether a moderate increase in iodine fortification would lead to excess iodine intake in this group. METHODS: Children in first and fifth grade were recruited through schools in Copenhagen. In total, 244...... children de-ivered a urine sample. Urine samples were analysed for iodine and creatinine, and the results were expressed as urinary iodine concentration (UIC) and as estimated 24-h iodine excretion. Iodine excretion in children was also compared with that of adults living in the same area, investigated...

  2. Synthesis and evaluation of novel polysaccharide-Gd-DTPA compounds as contrast agent for MRI

    Science.gov (United States)

    Sun, Guoying; Feng, Jianghua; Jing, Fengying; Pei, Fengkui; Liu, Maili

    2003-09-01

    Macromolecular conjugates of two kinds of natural polysaccharides, that from Panax quinquefolium linn (PQPS) and Ganoderma applanatum pat (GAPS), with gadolinium-diethylenetriaminepenta-acetic acid (Gd-DTPA) have been synthesized and characterized by means of FTIR, elementary analysis and ICP-AES. Their stability was investigated by competition study with Ca 2+, EDTA (ethylenediaminetetraacetic acid) and DTPA. Polysaccharide-bound complexes exhibit T1 relaxivities of 1.5-1.7 times that of Gd-DTPA in D 2O at 25°C and 9.4 T. MR imaging of Sprague-Dawley (SD) rats showed remarkable enhancement in rat liver and kidney after i.v. injection of these two complexes: liver parenchyma 60.9±5.6%, 57.8±7.4% at 65-85 min; kidney 144.9±14.5%, 199.9±25.4% at 10-30 min for PQPS-Gd-DTPA, GAPS-Gd-DTPA at gadolinium dose of 0.083 and 0.082 mmol/kg, respectively. Our preliminary in vivo and in vitro study indicates that the two kinds of polysaccharide-bound complexes are potential tissue-specific contrast agents for MRI.

  3. Lifetime measurement in 144Gd

    International Nuclear Information System (INIS)

    Jensen, H.J.; Gast, W.; Georgiev, A.; Jaeger, H.M.; Lieder, R.M.; Utzelmann, S.; Gierlik, M.; Morek, T.; Przestrzelska, K.; Rzaca-Urban, T.; Dewald, A.; Kuehn, R.; Meier, C.; Ender, C.; Haertlein, T.

    1996-01-01

    The lifetime measurements of excited states in 144 Gd were carried out using the Koeln RDM-plunger together with the 2 x 3 CLUSTER detector setup in Heidelberg. The nucleus was populated in the 100 Mo( 48 Ti,4n) 144 Gd reaction at a beam energy of 205 MeV giving a recoil velocity of v/c = 2.6 %. Three and higher fold γ-ray coincidences were measured at 12 target-stopper distances ranged from 0 to 400 μm. Both the dipole and quadrupole bands in 144 Gd have been observed. The analysis is in progress

  4. Enhanced Photocatalytic Activity of Rare Earth Metal (Nd and Gd doped ZnO Nanostructures

    Directory of Open Access Journals (Sweden)

    P. Logamani

    2017-06-01

    Full Text Available Presence of harmful organic pollutants in wastewater effluents causes serious environmental problems and therefore purification of this contaminated water by a cost effective treatment method is one of the most important issue which is in urgent need of scientific research. One such promising treatment technique uses semiconductor photocatalyst for the reduction of recalcitrant pollutants in water. In the present work, rare earth metals (Nd and Gd doped ZnO nanostructured photocatalyst have been synthesized by wet chemical method. The prepared samples were characterized by X-ray diffraction (XRD, Field Emission Scanning Electron Microscopy (FESEM and energy dispersive X-ray spectroscopy (EDS. The XRD results showed that the prepared samples were well crystalline with hexagonal Wurtzite structure. The results of EDS revealed that rare earth elements were doped into ZnO structure. The effect of rare earth dopant on morphology and photocatalytic degradation properties of the prepared samples were studied and discussed. The results revealed that the rare earth metal doped ZnO samples showed enhanced visible light photocatalytic activity for the degradation of methylene blue dye than pure nano ZnO photocatalyst.

  5. Hyaluronic Acid-Chitosan Nanoparticles to Deliver Gd-DTPA for MR Cancer Imaging

    Directory of Open Access Journals (Sweden)

    Li Zhang

    2015-08-01

    Full Text Available Molecular imaging is essential to increase the sensitivity and selectivity of cancer diagnosis especially at the early stage of tumors. Recently, polyionic nanocomplexes (PICs, which are composed of polyanions and opposite polycations, have been demonstrated to be a promising strategy for biomedical applications. In this work, chitosan-hyaluronic acid nanoparticles (GCHN were developed to deliver Gd-DTPA as MRI contrast agents for tumor diagnosis. The Gd-labeled conjugates (CS-DTPA-Gd were successfully synthesized by carbodiimide reaction, and then GCHN were prepared by ionic gelation using the obtained CS-DTPA-Gd and hyaluronic acid. The morphology of GCHN was spherical or ellipsoidal, which is observed by transmission electronic microscopy (TEM. The mean particle size and zeta potential of GCHN were 213.8 ± 2.6 nm and 19.92 ± 1.69 mV, respectively. The significant enhancement of signal intensity induced by GCHN was observed both in vitro and in vivo. Also, compared with Magnevist, GCHN was witnessed for a prolonged imaging time in the B16 tumor-bearing mice model. Furthermore, GCHN were verified as below toxic both in vitro and in vivo. These results indicated that GCHN could potentially be an alternative to current MRI contrast agents for tumor diagnosis.

  6. An investigation of the Pd-Ag-Ru-Gd quaternary system phase diagram

    International Nuclear Information System (INIS)

    Zhang Kanghou; Xu Yun

    2005-01-01

    On the basis of the Ag-Pd-Gd, Ag-Ru-Gd and Pd-Ru-Gd ternary systems, the partial phase diagram of Pd-Ag-Ru-Gd (Gd 3 Gd and Ag 51 Gd 14 ; five two-phase regions: Pd(Ag) + (Ru), Pd(Ag) + Ag 51 Gd 14 (Ru) + Ag 51 Gd 14 , Pd(Ag) + Pd 3 Gd and (Ru) + Pd 3 Gd; three three-phase regions: Pd(Ag) + Pd 3 Gd + (Ru), Pd(Ag) + Ag 51 Gd 14 + (Ru) and (Ru) + Ag 51 Gd 14 + Pd 3 Gd; one four-phase region Pd(Ag) + (Ru) + Ag 51 Gd 14 + Pd 3 Gd. No new quaternary intermetallic phase has been found

  7. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA-enhanced

  8. Estimation of the systemic burden of plutonium from urinary excretion data and a multi-exponential model for excretion in comparison with autopsy data

    International Nuclear Information System (INIS)

    Bernard, S.R.; Nestor, C.W.

    1985-01-01

    The authors have adapted other's method for computing the systemic burden from urinary excretion data to use a multi-exponential model (2) for excretion, rather than Langham's power function. The mathematical basis of Synder's method is the representation of the systemic burden as the convolution integral of the observed urinary excretion data with the inverse Laplace transform of the excretion function; in the case of urinary excretion of plutonium, the power function has a Laplace transform, but for other elements (notably uranium) it does not. If the method is to be used for other radioisotopes, the excretion function must have a Laplace transform, and for this reason we have used a multi-exponential form of the excretion function. They have written a computer program to calculate estimates of the systemic burden and the integrated intake from urinary excretion data, and have compared the results with two cases for which autopsy data are available, as presented in this paper

  9. Dynamic contrast-enhanced magnetic resonance imaging with Gd-EOB-DTPA for the evaluation of liver fibrosis in chronic hepatitis patients

    International Nuclear Information System (INIS)

    Chen, Bang-Bin; Hsu, Chao-Yu.; Yu, Chih-Wei; Wei, Shwu-Yuan; Shih, Tiffany Ting-Fang; Kao, Jia-Horng; Lee, Hsuan-Shu

    2012-01-01

    To develop a non-invasive MRI method for evaluation of liver fibrosis, with histological analysis as the reference standard. The study protocol was approved by the Institutional Review Board for Human Studies of our hospital, and written informed consent was obtained from all subjects. Seventy-nine subjects who received dynamic contrast-enhanced MRI (DCE-MRI) with Gd-EOB-DTPA were divided into three subgroups according to Metavir score: no fibrosis (n = 30), mild fibrosis (n = 34), and advanced fibrosis (n = 15). The DCE-MRI parameters were measured using two models: (1) dual-input single-compartment model for arterial blood flow (F a ), portal venous blood flow, total liver blood flow, arterial fraction (ART), distribution volume, and mean transit time; and (2) curve analysis model for Peak, Slope, and AUC. Statistical analysis was performed with Student's t-test and the nonparametric Kruskal-Wallis test. Slope and AUC were two best perfusion parameters to predict the severity of liver fibrosis (>F2 vs. ≤F2). Four significantly different variables were found between non-fibrotic versus mild-fibrotic subgroups: F a , ART, Slope, and AUC; the best predictor for mild fibrosis was F a (AUROC:0.701). DCE-MRI with Gd-EOB-DTPA is a noninvasive imaging, by which multiple perfusion parameters can be measured to evaluate the severity of liver fibrosis. (orig.)

  10. Gd-DTPA (gadolinium diethylenetriamine pentaacetic acid) in MR imaging of the internal derangement of temporomandibular joint

    International Nuclear Information System (INIS)

    Tange, Kazuhisa; Mihara, Manabu; Maeda, Sanae; Iwata, Hiroyuki; Ito, Noboru; Fukaya, Masahiko.

    1990-01-01

    Magnetic resonance (MR) imaging was performed in five internal derangement of temporomandibular joint (TMJ) patients, before and after intravenous administration of gadolinium-DTPA (Gd-DTPA) as a contrast agent. MR imaging was performed with a 0.5 tesla unit (VISTA MR; PICKER INTERNATIONAL) using a surface coil. We obtained multiple 5 mm sagital images with open and closed jaw positions. Precontrast proton density images were obtained with a repetition time (TR) of 1,000 msec and an echo time (TE) of 40 msec (TR/TE=1,000/40). Gd-DTPA was administered intravenously in a dose of 0.2 ml per kilogram of body weight. After the injection, postcontrast T1 weighted images (500/20) or postcontrast proton density images (1,000/40) were obtained. In the postcontrast T1 weighted images, the soft tissue surrounding the articular disk was enhanced and it provided helpful information for assessing the disk position. On the other hand, there was no effect of the contrast agent in the postcontrast proton density images. None of the patients experienced allergic reactions or other side effects. Gd-DTPA appeared to be a safe and effective contrast agent for MR imaging with T1 weighted images. However, compared with our usual imaging of the TMJ, the imaging did not indicate greater MR sensitivity for detecting the articular disk by means of Gd-DTPA enhancement. (author)

  11. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  12. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  13. Urinary magnesium excretion and risk of cardiovascular disease in the general population

    Directory of Open Access Journals (Sweden)

    Michel Joosten

    2012-06-01

    We prospectively followed 7747 adults free of diagnosed cardiovascular diseases or cancer at baseline (1997-1998 from the community-based, observational PREVEND (Prevention of Renal and Vascular End-Stage Disease Study. Urinary magnesium excretion was estimated from two 24-h urine collections and was measured by a xylidyl blue method on a Modular analyzer (Roche. During a median follow-up of 10.5 year, 638 CVD events occurred. After adjustment for age, BMI, sex, smoking status, alcohol consumption and educational attainment, urinary magnesium excretion showed a nonlinear relationship with CVD risk. The hazard ratios (HR for CVD were significantly lower (PIn conclusion, low urinary magnesium excretion was associated with a higher risk of CVD, even after controlling for possible intermediates in the causal pathway such as blood pressure, diabetes and markers of inflammation and atherosclerosis. These results highlight the need to evaluate whether increasing the uptake of dietary magnesium could be effective for primary prevention of CVD.

  14. Mouldy feed: A possible explanation for the excretion of anabolic-androgenic steroids in horses.

    Science.gov (United States)

    Decloedt, A I; Bailly-Chouriberry, L; Vanden Bussche, J; Garcia, P; Popot, M-A; Bonnaire, Y; Vanhaecke, L

    2016-05-01

    To ensure fair competition and to protect the horse's welfare, horses have to compete on their own merits, without any unfair advantage that might follow the use of drugs. Therefore, regulatory authorities list all substances that are not allowed in competition, including most anabolic-androgenic steroids. As zero-tolerance is retained, the question arose whether the consumption of mouldy feed could lead to the excretion of steroids, due to the biotransformation of plant phytosterols to steroids. A rapid ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analytical method, previously validated according to AORC (Association of Official Racing Chemists) and EC (European Commission) guidelines, was used to measure steroids in different sample types. Multiple mouldy feed samples were tested for the presence of steroids. The effect of digestion was tested by in vitro simulation of the horse's hindgut in batch incubations. In most feed samples no steroids were detected, even when the products were mouldy. Mouldy corn however showed to contain up to 3.0 ± 0.4 µg/kg AED (4-androstenedione), the main testosterone precursor. This concentration increased when mouldy corn (with added phytosterols) was digested in vitro. An herbal phytosupplement also showed to contain α-testosterone. These results demonstrate that it is important to caution against the consumption of any feed or (herbal) supplement of which the detailed ingredients and quantitative analysis are unknown. The consumption of mouldy corn should especially be avoided, not only from a horse health and welfare point of view, but also to avoid possible inadvertent positive doping results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Estimation of Body Composition from Urinay Creatinine Excretion

    OpenAIRE

    小室, 史恵; 小宮, 秀一

    1982-01-01

    Simultaneous determinations of total body water, using the deuterium oxide dilution method, and urinary creatinine excretion have been carried out in 26 males and females. Total body water and FFM may be predicted from urinary creatinine excretion by T.B.W.=0.0165 Cr. +17.773. FFM=0.0225 Cr. +17.446. In this subjects a high correlation (r=0.874) was found between T.B.W, FFM and urinary creatinine excretion. It appears that FFM can be predicted from urinary creatinine excretion.

  16. Alginate enhances excretion and reduces absorption of strontium and cesium in rats

    International Nuclear Information System (INIS)

    Idota, Yoko; Harada, Hitomi; Tomono, Takumi; Morimoto, Kaori; Kakinuma, Chihaya; Ogihara, Takuo; Kobayashi, Shoko; Miyajima, Chihiro; Kasahara, Fumiyoshi

    2013-01-01

    Alginate (ALA), which is an intercellular polysaccharide associated with brown algae, is used as a food additive, a health food and a medicine. Here, we first examined the adsorption of strontium (Sr) and cesium (Cs) by ALA in vitro, and then evaluated the effects of ALA on absorption and excretion of Sr and Cs in rats, in order to evaluate its potential usefulness for minimizing radiation damage from materials released after a nuclear accident. Both Sr and Cs were concentration-dependently adsorbed by sodium alginate (ALA-Na) in vitro. In rats given diet containing either ALA-Na or calcium alginate (ALA-Ca) for two weeks, the plasma concentration of Sr gradually decreased compared with the controls (normal diet); however, in the case of Cs, the plasma concentration was decreased only in the ALA-Ca group, but not the ALA-Na group. Moreover, we examined the effect of preadministration of diet containing either ALA-Na or ALA-Ca on absorption of Sr and Cs administered orally as the chloride salts to rats. Absorption of both Sr and Cs was reduced in the ALA-Ca group, while absorption of only Sr was reduced in the ALA-Na group. Safety assessments indicated that ALA-Ca is safer than ALA-Na. These results indicate that ALA-Ca reduces absorption and promotes excretion of both Sr and Cs, while ALA-Na does so only for Sr. (author)

  17. Pharmacokinetics and Biliary Excretion of Fisetin in Rats.

    Science.gov (United States)

    Huang, Miao-Chan; Hsueh, Thomas Y; Cheng, Yung-Yi; Lin, Lie-Chwen; Tsai, Tung-Hu

    2018-06-14

    The hypothesis of this study is that fisetin and phase II conjugated forms of fisetin may partly undergo biliary excretion. To investigate this hypothesis, male Sprague-Dawley rats were used for the experiment, and their bile ducts were cannulated with polyethylene tubes for bile sampling. The pharmacokinetic results demonstrated that the average area-under-the-curve (AUC) ratios ( k (%) = AUC conjugate /AUC free-form ) of fisetin, its glucuronides, and its sulfates were 1:6:21 in plasma and 1:4:75 in bile, respectively. Particularly, the sulfated metabolites were the main forms that underwent biliary excretion. The biliary excretion rate ( k BE (%) = AUC bile /AUC plasma ) indicates the amount of fisetin eliminated by biliary excretion. The biliary excretion rates of fisetin, its glucuronide conjugates, and its sulfate conjugates were approximately 144, 109, and 823%, respectively, after fisetin administration (30 mg/kg, iv). Furthermore, biliary excretion of fisetin is mediated by P-glycoprotein.

  18. NMR relaxometric properties and cytotoxicity of Gd2O3 nanoparticle suspensions in an organic liquid

    Science.gov (United States)

    Babić-Stojić, Branka; Jokanović, Vukoman; Milivojević, Dušan; Požek, Miroslav; Jagličić, Zvonko; Makovec, Darko; Arsikin, Katarina; Paunović, Verica

    2014-10-01

    Gd2O3 nanoparticles and their agglomerates from approximately 10 to 80 nm in size suspended in an organic liquid were synthesized via polyol route. The reaction between diethylene glycol and added acetic acid, which occurred simultaneously with the synthesis of Gd2O3 nanoparticles, was catalyzed by sodium bisulfate to transform as much as possible diethylene glycol in corresponding ester at the end of complete reaction. The produced nanosized material of gadolinium oxide was investigated by TEM, DLS, FTIR spectroscopy, and NMR relaxometry. Biological evaluation of this material was done by MTT and crystal violet assays to determine the cell viability. Longitudinal and transverse relaxivities of water-diluted Gd2O3 nanoparticle suspensions estimated to be r 1 = 13.6 and r 2 = 14.7 s-1 mM-1 are about three times higher compared to the relaxivities obtained for standard contrast agent Gd-DTPA (Magnevist). Good MRI signal intensities of the water-diluted Gd2O3 nanoparticle suspensions were recorded in the Gd concentration range 0.2-0.3 mM for which the suspensions were not toxic exhibiting simultaneously higher signal intensities than those for Magnevist in the Gd concentration range 0.4-1 mM for which this standard contrast agent was not toxic. These properties make the produced Gd2O3 nanoparticle material promising for potential application as MRI contrast agent.

  19. In vivo transport of Gd-DTPA2- into human meniscus and cartilage assessed with delayed gadolinium-enhanced MRI of cartilage (dGEMRIC)

    Science.gov (United States)

    2014-01-01

    Background Impaired stability is a risk factor in knee osteoarthritis (OA), where the whole joint and not only the joint cartilage is affected. The meniscus provides joint stability and is involved in the early pathological progress of OA. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been used to identify pre-radiographic changes in the cartilage in OA, but has been used less commonly to examine the meniscus, and then using only a double dose of the contrast agent. The purpose of this study was to enable improved early OA diagnosis by investigate the temporal contrast agent distribution in the meniscus and femoral cartilage simultaneously, in healthy volunteers, using 3D dGEMRIC at two different doses of the contrast agent Gd-DTPA2-. Methods The right knee in 12 asymptomatic volunteers was examined using a 3D Look-Locker sequence on two occasions after an intravenous injection of a double or triple dose of Gd-DTPA2- (0.2 or 0.3 mmol/kg body weight). The relaxation time (T1) and relaxation rate (R1 = 1/T1) were measured in the meniscus and femoral cartilage before, and 60, 90, 120 and 180 minutes after injection, and the change in relaxation rate (ΔR1) was calculated. Paired t-test and Analysis of Variance (ANOVA) were used for statistical evaluation. Results The triple dose yielded higher concentrations of Gd-DTPA2- in the meniscus and cartilage than the double dose, but provided no additional information. The observed patterns of ΔR1 were similar for double and triple doses of the contrast agent. ΔR1 was higher in the meniscus than in femoral cartilage in the corresponding compartments at all time points after injection. ΔR1 increased until 90-180 minutes in both the cartilage and the meniscus (p meniscus at all time points (p meniscus, than in the avascular central part of the posterior medial meniscus during the first 60 minutes (p meniscus and cartilage simultaneously using dGEMRIC, preferably 90 minutes after the injection of a

  20. Anomalous Hall effect in Fe/Gd bilayers

    KAUST Repository

    Xu, W. J.; Zhang, Bei; Liu, Z. X.; Wang, Z.; Li, W.; Wu, Z. B.; Yu, R. H.; Zhang, Xixiang

    2010-01-01

    Non-monotonic dependence of anomalous Hall resistivity on temperature and magnetization, including a sign change, was observed in Fe/Gd bilayers. To understand the intriguing observations, we fabricated the Fe/Gd bilayers and single layers of Fe and Gd simultaneously. The temperature and field dependences of longitudinal resistivity, Hall resistivity and magnetization in these films have also been carefully measured. The analysis of these data reveals that these intriguing features are due to the opposite signs of Hall resistivity/or spin polarization and different Curie temperatures of Fe and Gd single-layer films. Copyright (C) EPLA, 2010

  1. Anomalous Hall effect in Fe/Gd bilayers

    KAUST Repository

    Xu, W. J.

    2010-04-01

    Non-monotonic dependence of anomalous Hall resistivity on temperature and magnetization, including a sign change, was observed in Fe/Gd bilayers. To understand the intriguing observations, we fabricated the Fe/Gd bilayers and single layers of Fe and Gd simultaneously. The temperature and field dependences of longitudinal resistivity, Hall resistivity and magnetization in these films have also been carefully measured. The analysis of these data reveals that these intriguing features are due to the opposite signs of Hall resistivity/or spin polarization and different Curie temperatures of Fe and Gd single-layer films. Copyright (C) EPLA, 2010

  2. Estimation of skeletal plutonium levels based on DTPA-induced radionuclide excretion in feces: possible application to man

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, M H; Guilmette, R A; Peterson, D P; Chao, F C; Lindinbaum, A [Argonne National Lab., IL (USA)

    1978-06-01

    A new approach to the estimation of plutonium (Pu) levels in the skeleton based on measurements of Pu excretion in the feces following treatment with diethylenetriaminepentaacetic acid (DPTA) is presented. The estimation method was tested in groups of mice receiving either 0.5 or 5 ..mu.. Ci/kg of /sup 239/Pu(IV) citrate, and treated with Na/sub 3/(CaDTPA) starting either at 1 hr or 24 hr after Pu administration. In the case of DTPA treatment begun at 1 hr, the ratio of skeletal Pu content at 1 hr, S, to DTPA-induced fecal excretion of Pu, F, was 1.08 +- 0.03. When DTPA treatment was begun at 24 hr, the corresponding S/F ratio was 1.68 +- 0.08 and was independent of Pu injection level. In the mouse, therefore, a reasonable estimate of skeletal Pu content just prior to treatment can be determined from the amount of Pu measured in the feces following DTPA therapy. Application of this method to species other than the mouse is examined, with anticipation that the method might be applicable to cases of human exposure.

  3. Optimizing the Relaxivity of MRI Probes at High Magnetic Field Strengths With Binuclear GdIII Complexes

    Directory of Open Access Journals (Sweden)

    Loredana Leone

    2018-05-01

    Full Text Available The key criteria to optimize the relaxivity of a Gd(III contrast agent at high fields (defined as the region ≥ 1.5 T can be summarized as follows: (i the occurrence of a rotational correlation time τR in the range of ca. 0.2–0.5 ns; (ii the rate of water exchange is not critical, but a τM < 100 ns is preferred; (iii a relevant contribution from water molecules in the second sphere of hydration. In addition, the use of macrocycle-based systems ensures the formation of thermodynamically and kinetically stable Gd(III complexes. Binuclear Gd(III complexes could potentially meet these requirements. Their efficiency depends primarily on the degree of flexibility of the linker connecting the two monomeric units, the absence of local motions and the presence of contribution from the second sphere water molecules. With the aim to maximize relaxivity (per Gd over a wide range of magnetic field strengths, two binuclear Gd(III chelates derived from the well-known macrocyclic systems DOTA-monopropionamide and HPDO3A (Gd2L1 and Gd2L2, respectively were synthesized through a multistep synthesis. Chemical Exchange Saturation Transfer (CEST experiments carried out on Eu2L2 at different pH showed the occurrence of a CEST effect at acidic pH that disappears at neutral pH, associated with the deprotonation of the hydroxyl groups. Then, a complete 1H and 17O NMR relaxometric study was carried out in order to evaluate the parameters that govern the relaxivity associated with these complexes. The relaxivities of Gd2L1 and Gd2L2 (20 MHz, 298 K are 8.7 and 9.5 mM−1 s−1, respectively, +77% and +106% higher than the relaxivity values of the corresponding mononuclear GdDOTAMAP-En and GdHPDO3A complexes. A significant contribution of second sphere water molecules was accounted for the strong relaxivity enhancement of Gd2L2. MR phantom images of the dinuclear complexes compared to GdHPDO3A, recorded at 7 T, confirmed the superiority of Gd2L2. Finally, ab initio

  4. Large negative magnetoresistance in reactive sputtered polycrystalline GdNx films

    KAUST Repository

    Mi, W. B.; Guo, Z. B.; Duan, X. F.; Zhang, X. J.; Bai, H. L.

    2013-01-01

    Polycrystalline ferromagnetic GdN x films were fabricated at different N2 flow rates ( fN2 ) to modify N-vacancy concentration so as to study its influence on electrotransport. Metal-semiconductor transition appears at Curie temperature (TC ) of ∼40 K. Temperature-dependent magnetoresistance (MR) shows a peak at T C. The films at fN2  = 5, 10, 15, and 20 sccm show MR of −38%, −42%, −46%, and −86% at 5 K and 50 kOe, respectively. Above 15 K, MR is from colossal MR and from both colossal and tunneling MR below 15 K. The enhanced MR at fN2  = 20 sccm is attributed to large spin polarization of half-metallicity in GdN x with low N vacancies.

  5. Large negative magnetoresistance in reactive sputtered polycrystalline GdNx films

    KAUST Repository

    Mi, W. B.

    2013-06-07

    Polycrystalline ferromagnetic GdN x films were fabricated at different N2 flow rates ( fN2 ) to modify N-vacancy concentration so as to study its influence on electrotransport. Metal-semiconductor transition appears at Curie temperature (TC ) of ∼40 K. Temperature-dependent magnetoresistance (MR) shows a peak at T C. The films at fN2  = 5, 10, 15, and 20 sccm show MR of −38%, −42%, −46%, and −86% at 5 K and 50 kOe, respectively. Above 15 K, MR is from colossal MR and from both colossal and tunneling MR below 15 K. The enhanced MR at fN2  = 20 sccm is attributed to large spin polarization of half-metallicity in GdN x with low N vacancies.

  6. Magnetic bubbles and domain evolution in Fe/Gd multilayer nanodots

    Science.gov (United States)

    Wang, T. T.; Liu, W.; Dai, Z. M.; Zhao, X. T.; Zhao, X. G.; Zhang, Z. D.

    2018-04-01

    The formation of magnetic bubbles and the domain-evolution processes, induced by a perpendicular magnetic field in Fe/Gd multilayer films and nanodots, have been investigated. At room temperature, the stripe domains in a continuous film transform into magnetic bubbles in an external field, while bubbles form spontaneously in nanodots due to the existence of shape anisotropy. When the temperature decreases to 20 K, the enhancement of the perpendicular magnetic anisotropy of the samples results in an increase of the domain size in the continuous film and the magnetization-reversal behavior of each nanodot becomes independent, and most reversed dots do not depend on each other, indicating the magnetic characteristics of a single domain. The present research provides further understanding of the evolution of magnetic bubbles in the Fe/Gd system and suggests their promising applications in patterned recording materials.

  7. Phase equilibrium of the Gd-Fe-Co system at 873 K

    International Nuclear Information System (INIS)

    Huang Jinli; Zhong Haichang; Xia Xiuwen; He Wei; Zhu Jinming; Deng Jianqiu; Zhuang Yinghong

    2009-01-01

    Phase equilibrium of the ternary Gd-Fe-Co system at 873 K was investigated by using X-ray diffraction technique, electron probe microanalysis, metallographic analysis and differential thermal analysis. The 873 K isothermal section of the phase diagram of the Gd-Fe-Co ternary system consists of 11 single-phase regions, 16 two-phase regions and 6 three-phase regions. Three pairs of corresponding compounds of Gd-Co and Gd-Fe, i.e., Gd 2 Co 17 and Gd 2 Fe 17 , GdCo 3 and GdFe 3 , GdCo 2 and GdFe 2 , form a continuous series of solid solution. The compound Gd 2 Co 7-x Fe x was found to have a broad solubility range from 0 to 31 at.% Fe. The maximum solubility of Co in Gd 6 Fe 23 is about 7 at.% Co. At 873 K, the maximum solubilities of Fe in Gd 3 Co and Gd 4 Co 3 are about 3 and 1 at.% Fe, respectively. No ternary compound was found in all ternary alloy samples

  8. Hyperfine structure in the Gd II spectrum and the nuclear electric quadrupole moment of 157Gd

    International Nuclear Information System (INIS)

    Clieves, H.P.; Steudel, A.

    1979-01-01

    The hyperfine structure of 157 Gd was investigated in 20 Gd II lines by means of a photoelectric recording Fabry-Perot interferometer with digital data processing. The hyperfine splitting factors, A and B, were obtained by computer fits to the observed line structures. Using a multiconfigurational set of wave functions in intermediate coupling derived by Wyart, mono-electronic parameters were deduced by a parametric treatment. The nuclear electric quadrupole moment of 157 Gd was evaluated from the quadrupole interaction of the 5d electron in 4f 7 5d6s, the 5d electron in 4f 7 5d6p, and the 6p electron in 4f 7 5d6p. The three values obtained for the quadrupole moment agree very well. The final result, corrected for Sternheimer shielding, is Q( 157 Gd) = 1.34(7) x 10 -24 cm 2 . (orig.) [de

  9. Two-dimensional TiO_2-based nanosheets co-modified by surface-enriched carbon dots and Gd_2O_3 nanoparticles for efficient visible-light-driven photocatalysis

    International Nuclear Information System (INIS)

    Lu, Dingze; Fang, Pengfei; Ding, Junqian; Yang, Minchen; Cao, Yufei; Zhou, Yawei; Peng, Kui; Kondamareddy, Kiran Kumar; Liu, Min

    2017-01-01

    Highlights: • Gd-C-TNSs with high stability and recycle usability were prepared by two-pot method. • Gd_2O_3 loading results in the structure changes of TNSs and increase of the Ti"3"+ ions. • Modified CDs leads to obvious increase of optical absorption ability and red shift. • Appropriate amount of Gd_2O_3 nanoparticles and CDs improve the separation of charges. • Gd-C-TNSs exhibit excellent synergistic photocatalytic activity for Cr(VI) and RhB. - Abstract: Two-dimensional TiO_2-based nanosheets (TNSs) co-modified by surface-enriched carbon dots (CDs) and Gd_2O_3 nanoparticles: (Gd-C-TNSs), capable of exhibiting visible-light-driven photo catalysis were synthesized using a two-pot hydrothermal route. The samples had a sheet-like structure, thickness of approximately 3.6 nm, large specific surface area of 240–350 cm"2/g. The CDs (2–3 nm) and Gd_2O_3 nanoparticles (1–2 nm) were highly dispersed over the surface of the nanosheets. The co-modification by Gd_2O_3 nanoparticles and CDs influenced the crystallinity, crystal structure, and surface area of the TNSs, and improved the visible-light absorption. Surface photocurrent and fluorescence spectral studies revealed that the photo-generated charge carrier separation efficiency could be improved by an appropriate amount of modification. A very high efficiency was obtained using 0.5 at% Gd/Ti and 3.0 g/L of CDs. The visible-light-induced photocatalytic activity is enhanced under the isolated Cr(VI) system, isolated Rhodamin B (RhB) system, and the synergism between RhB degradation and Cr(VI) reduction for the Gd-C-TNSs photocatalysts. Initially, the photocatalytic activity gradually increased with an increase in the amount of CDs, and then decreased after attaining a maximum, in the case where 0.5 at% Gd/Ti and 3.0 g/L of CDs were used. The enhancement in the photocatalytic activity was attributed to the synergetic effect of the Gd_2O_3 nanoparticles, TNSs, and CDs in the Gd-C-TNSs composites. The

  10. Excretion and toxicity evaluation of 131I-Sennoside A as a necrosis-avid agent.

    Science.gov (United States)

    Yin, Zhiqi; Sun, Lidan; Jin, Qiaomei; Song, Shaoli; Feng, Yuanbo; Liao, Hong; Ni, Yicheng; Zhang, Jian; Liu, Wei

    2017-11-01

    1. Sennoside A (SA) is a newly identified necrosis-avid agent that shows capability for imaging diagnosis and tumor necrosis targeted radiotherapy. As a water-soluble compound, 131 I-Sennoside A ( 131 I-SA) might be excreted predominately through the kidneys with the possibility of nephrotoxicity. 2. To further verify excretion pathway and examine nephrotoxicity of 131 I-SA, excretion and nephrotoxicity were appraised. The pharmacokinetics, hepatotoxicity and hematotoxicity of 131 I-SA were also evaluated to accelerate its possible clinical translation. All these studies were conducted in mice with ethanol-induced muscular necrosis following a single intravenous administration of 131I-SA at 18.5 MBq/kg or 370 MBq/kg. 3. Excretion data revealed that 131 I-SA was predominately (73.5% of the injected dose (% ID)) excreted via the kidneys with 69.5% ID detected in urine within 72 h post injection. Biodistribution study indicated that 131 I-SA exhibited initial high distribution in the kidneys but subsequently a fast renal clearance, which was further confirmed by the results of autoradiography and single-photon emission computed tomography-computed tomography (SPECT-CT) imaging. The maximum necrotic to normal muscle ratio reached to 7.9-fold at 48 h post injection, which further verified the necrosis avidity of 131 I-SA. Pharmacokinetic parameters showed that 131 I-SA had fast blood clearance with an elimination half-life of 6.7 h. Various functional indexes were no significant difference (p > 0.05) between before administration and 1 d, 8 d, 16 d after administration. Histopathology showed no signs of tissue damage. 4. These data suggest 131 I-SA is a safe and promising necrosis-avid agent applicable in imaging diagnosis and tumor necrosis targeted radiotherapy.

  11. Late excretion of plutonium following acquisition of known amounts

    International Nuclear Information System (INIS)

    Rundo, J.

    1981-01-01

    The urinary and fecal excretion rates of plutonium 10,000 days after intravenous injection of known amounts are compared with the predictions of various models. Both Langham's and Durbin's equations underestimated the urinary excretion by about an order of magnitude; the observed fecal excretion rates were also higher than the predictions. The total excretion rate predicted by the ICRP model was in quite good agreement with the observed rate, but it overestimated it at early times ( 239 Pu of former Manhattan Project plutonium workers, as calculated from the measured urinary excretion an application of Langham's equation. In one of these subjects the urinary excretion rate started to increase at about 6000 days, reached a maximum at about 9500 days, and declined for the next 2700 days

  12. Flip angle modulations in late phase Gd-EOB-DTPA MRI improve the identification of the biliary system

    Energy Technology Data Exchange (ETDEWEB)

    Stelter, Lars, E-mail: lars.stelter@charite.de [Klinik fuer Radiologie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Grieser, Christian, E-mail: christian.grieser@charite.de [Klinik fuer Radiologie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Fernandes, Carmen Maria Perez, E-mail: carmen.perez-fernandez@charite.de [Klinik fuer Radiologie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Rothe, Jan Holger, E-mail: jan-holger.rothe@charite.de [Klinik fuer Radiologie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Streitparth, Florian, E-mail: florian.streitparth@charite.de [Klinik fuer Radiologie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Seehofer, Daniel, E-mail: daniel.seehofer@charite.de [Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Charite - Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); and others

    2012-11-15

    Objectives: To assess the improvement of bile duct visualization in Gd-EOB-DTPA enhanced MR-cholangiography (EOB-MRC) by using an increased flip angle. Methods: 35 patients underwent Gd-EOB-DTPA enhanced MRI of the liver including T2-weighted MRCP and hepatobiliary phase EOB-MRC using a flip angle of 10 Degree-Sign (FA10) and of 35 Degree-Sign (FA35), respectively. Images were evaluated regarding the delineation of biliary ducts, the order of branching and anatomic visualization of the biliary tree. ROI analysis was performed to estimate the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Results: Applying the FA35 resulted in a significantly better SNR and CNR as compared to FA10. The overall image quality was rated as good for both, FA10 and FA35. The overall rating for regional delineation of the biliary system was rated significantly better for FA35 than for FA10 (p = 0.02). Classification of bile duct anatomy variations, however, was equivalent in both techniques. Conclusions: Increasing the flip angle of a T1-weighted 3D-sequence from 10 Degree-Sign to 35 Degree-Sign during the hepatobiliary phase of Gd-EOB enhanced MRI visually and quantitatively improved the visualization of the biliary ducts.

  13. Additive effect of BPA and Gd-DTPA for application in accelerator-based neutron source

    International Nuclear Information System (INIS)

    Yoshida, F.; Yamamoto, T.; Nakai, K.; Zaboronok, A.; Matsumura, A.

    2015-01-01

    Because of its fast metabolism gadolinium as a commercial drug was not considered to be suitable for neutron capture therapy. We studied additive effect of gadolinium and boron co-administration using colony forming assay. As a result, the survival of tumor cells with additional 5 ppm of Gd-DTPA decreased to 1/10 compared to the cells with boron only. Using gadolinium to increase the effect of BNCT instead of additional X-ray irradiation might be beneficial, as such combination complies with the short-time irradiation regimen at the accelerator-based neutron source. - Highlights: • Gd-DTPA is widely clinically used as a contrast medium for MRI. • Shift to an accelerator-based neutron source is advantageous for gadolinium NCT. • Boron–gadolinium NCT effects on tumor cell lines were significant. • Additional administration of Gd-DTPA might enhance the effect of BPA–BNCT.

  14. Gd-doped GaN studied with element specificity: Very small polarization of Ga, paramagnetism of Gd and the formation of magnetic clusters

    Energy Technology Data Exchange (ETDEWEB)

    Ney, A., E-mail: ney@maglomat.d [Fachbereich Physik and Center for Nanointegration Duisburg-Essen (CeNIDE), Universitaet Duisburg-Essen, Lotharstr. 1, D-47057 Duisburg (Germany); Kammermeier, T.; Ollefs, K.; Ney, V.; Ye, S. [Fachbereich Physik and Center for Nanointegration Duisburg-Essen (CeNIDE), Universitaet Duisburg-Essen, Lotharstr. 1, D-47057 Duisburg (Germany); Dhar, S. [Fachbereich Physik and Center for Nanointegration Duisburg-Essen (CeNIDE), Universitaet Duisburg-Essen, Lotharstr. 1, D-47057 Duisburg (Germany); Paul-Drude-Institut fuer Festkoerperelektronik, Hausvogteiplatz 5-7, D-10117 Berlin (Germany); Ploog, K.H. [Paul-Drude-Institut fuer Festkoerperelektronik, Hausvogteiplatz 5-7, D-10117 Berlin (Germany); Roever, M.; Malindretos, J.; Rizzi, A. [IV. Physikalisches Institut and Virtual Institute of Spinelectronics (VISel), Georg August Universitaet Goettingen, D-37077 Goettingen (Germany); Wilhelm, F.; Rogalev, A. [European Synchrotron Radiation Facility (ESRF), 6 Rue Jules Horowitz, BP 220, 38043 Grenoble Cedex (France)

    2010-05-15

    Element specific X-ray linear dichroism (XLD), X-ray magnetic circular dichroism (XMCD) at the Ga K- and Ga and Gd L{sub 3}-edges and magnetic resonance measurements have been carried out on Gd:GaN grown by molecular beam epitaxy with different Gd concentrations. XMCD studies at the Ga K-edge reveal only a very weak magnetic polarization, which is too small to account for the colossal moments reported before by SQUID. In the dilute limit we can show by XLD that the majority of the Gd dopant atoms go to substitutional Ga sites. XMCD studies demonstrate that the Gd sublattice behaves paramagnetic which is in contrast to integral SQUID measurements. The absence of ferromagnetic order at room temperature is corroborated by magnetic resonance studies. First signatures of phase separation are visible. At higher Gd concentrations phase separation is found by XLD. In such samples ferromagnetic-like order is consistently found by SQUID, XMCD and magnetic resonance which is characteristic for a blocked superparamagnetic ensemble. In turn, phase separated ferromagnetic Gd/GdN clusters cannot account for magnetic order observed at and above 300 K by SQUID.

  15. Histological examination of the gadolinium-enhanced dura mater around meningiomas on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sakai, Keiichi; Tada, Tsuyoshi; Fukasaku, Kazuaki; Kyoshima, Kazuhiko; Kobayashi, Shigeaki

    1993-01-01

    Magnetic resonance imaging often demonstrates gadolinium (Gd) enhancement of the dura mater around meningiomas. The Gd-enhanced dura mater was histologically investigated to detect meningioma cells. Gd enhancement of the dura mater occurred in 11 (79%) of the 14 meningiomas studied, and extended as far as 35 mm from the tumor. Histological examination revealed generation of vascular-rich loose connective tissue at the surface of the dura in all five tumors examined. Some clusters of meningothelial cells were distributed in the loose connective tissue in three of the five specimens, and one cluster was obviously neoplastic. These observations suggest that clusters of meningioma cells occur in the Gd-enhanced dura mater around meningiomas. (author)

  16. Histological examination of the gadolinium-enhanced dura mater around meningiomas on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Keiichi; Tada, Tsuyoshi; Fukasaku, Kazuaki; Kyoshima, Kazuhiko; Kobayashi, Shigeaki [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1993-07-01

    Magnetic resonance imaging often demonstrates gadolinium (Gd) enhancement of the dura mater around meningiomas. The Gd-enhanced dura mater was histologically investigated to detect meningioma cells. Gd enhancement of the dura mater occurred in 11 (79%) of the 14 meningiomas studied, and extended as far as 35 mm from the tumor. Histological examination revealed generation of vascular-rich loose connective tissue at the surface of the dura in all five tumors examined. Some clusters of meningothelial cells were distributed in the loose connective tissue in three of the five specimens, and one cluster was obviously neoplastic. These observations suggest that clusters of meningioma cells occur in the Gd-enhanced dura mater around meningiomas. (author).

  17. Magnetic resonance characterization of tumor microvessels in experimental breast tumors using a slow clearance blood pool contrast agent (carboxymethyldextran-A2-Gd-DOTA) with histopathological correlation

    International Nuclear Information System (INIS)

    Preda, Anda; Novikov, Viktor; Moeglich, Martina; Turetschek, Karl; Shames, David M.; Roberts, Timothy P.L.; Brasch, Robert C.; Floyd, Eugenia; Carter, Wayne O.; Corot, Claire

    2005-01-01

    Carboxymethyldextran (CMD)-A2-Gd-DOTA, a slow clearance blood pool contrast agent with a molecular weight of 52.1 kDa, designed to have intravascular residence for more than 1 h, was evaluated for its potential to characterize and differentiate the microvessels of malignant and benign breast tumors. Precontrast single-slice inversion-recovery snapshot FLASH and dynamic contrast-enhanced MRI using an axial T1-weighted three-dimensional spoiled gradient recalled sequence was performed in 30 Sprague-Dawley rats with chemically induced breast tumors. Endothelial transfer coefficient and fractional plasma volume of the breast tumors were estimated from MRI data acquired with CMD-A2-Gd-DOTA enhancement injected at a dose of 0.1 mmol Gd/kg body weight using a two-compartment bidirectional model of the tumor tissue. The correlation between MRI microvessel characteristics and histopathological tumor grade was determined using the Scarff-Bloom-Richardson method. Using CMD-A2-Gd-DOTA, no significant correlations were found between the MR-estimated endothelial transfer coefficient or plasma volumes with histological tumor grade. Analysis of CMD-A2-Gd-DOTA-enhanced MR kinetic data failed to demonstrate feasibility for the differentiation of benign from malignant tumors or for image-based tumor grading. (orig.)

  18. Hot channel calculation methodologies in case of Gd burnable poison

    International Nuclear Information System (INIS)

    Panka, I.; Kereszturi, A.

    2008-01-01

    The final step in the safety analysis is the investigation of the fulfilment of the acceptance criteria using hot channel calculations. Recently, there has been under way at Paks NPP to introduce a new, higher enriched (4.2 %) fuel type containing Gd burnable poison. To do that, for some transients the DBA analyses must be repeated and last year, as one of the first steps in this process, it was needed to review the hot channel calculation methodologies used in the analyses. The goal of the paper is to summarize some aspects of the hot channel calculation methodologies using different lattice pitches and different fuel types (Gd or non Gd and different enrichments). Mainly, three topics are discussed. First, the influence of the radial power distribution (and other burnup dependent parameters) inside the fuel pin are investigated, and then we discuss the problem of the selection of the appropriate 'frame parameter' in connection with the initial power level at the initial stationary state of DBA transients. Finally, we are trying to answer the question: is it possible to build up a conservative single closed sub-channel approach against multi channel approach?(Authors)

  19. Gadolinium-DTPA enhanced MRI of the brain

    International Nuclear Information System (INIS)

    Hosten, N.; Felix, R.

    1994-01-01

    The text reviews MRI findings in a variety of cerebral diseases. Advantages of Gadolinium-DTPA (Gd-DTPA) enhanced MRI over plain MRI and enhanced CT are discussed. Enhanced MRI is far superior to enhanced CT in the detection of meningeal tumor spread, meningeal inflammation, inflammatory lesions of the optic nerve, brain lesions in multiple sclerosis and infarction. Enhanced MRI is today the most sensitive diagnostic tool in hypophaseal adenomas. Also enhancement of gliomas is detected by MRI with higher sensitivity than by CT. Use Gd-DTPA allow to separate of vital tumor tissue from necrosis and edema, improve delineation of tumor extension and improve detection of lesions localized in gray matter

  20. Technological aspects concerning the production procedures of UO2-Gd2O3 nuclear fuel

    International Nuclear Information System (INIS)

    Durazzo, Michelangelo; Riella, Humberto Gracher

    2007-01-01

    The direct incorporation of Gd 2 O 3 powder into UO 2 powder by dry mechanical blending is the most attractive process for producing UO 2 -Gd 2 O 3 nuclear fuel. However, previous experimental results by our group indicated that pore formation due to the Kirkendall effect delays densification and, consequently, diminishes the final density of this type of nuclear fuel. Considering this mechanism as responsible for the poor sintering behavior of UO 2 -Gd 2 O 3 fuel prepared by the mechanical blending method, it was possible to propose, discuss and, in certain cases, preliminarily test feasible adjustments in fabrication procedures that would minimize, or even totally compensate, the negative effects of pore formation due to the Kirkendall effect. This work presents these considerations. (author)

  1. Investigation of nanocrystalline Gd films loaded with hydrogen

    KAUST Repository

    Hruška, Petr; Čí žek, Jakub; Dobroň, Patrik; Anwand, Wolfgang; Mü cklich, Arndt; Gemma, Ryota; Wagner, Stefan; Uchida, Helmut; Pundt, Astrid

    2015-01-01

    The present work reports on microstructure studies of hydrogen-loaded nanocrystalline Gd films prepared by cold cathode beam sputtering on sapphire (112¯0) substrates. The Gd films were electrochemically step-by-step charged with hydrogen and the structural development with increasing concentration of absorbed hydrogen was studied by transmission electron microscopy and in-situ   X-ray diffraction using synchrotron radiation. The relaxation of hydrogen-induced stresses was examined by acoustic emission measurements. In the low concentration range absorbed hydrogen occupies preferentially vacancy-like defects at GBs typical for nanocrystalline films. With increasing hydrogen concentration hydrogen starts to occupy interstitial sites. At the solid solution limit the grains gradually transform into the ββ-phase (GdH2). Finally at high hydrogen concentrations xH>2.0xH>2.0 H/Gd, the film structure becomes almost completely amorphous. Contrary to bulk Gd specimens, the formation of the γγ-phase (GdH3) was not observed in this work.

  2. The alkaline tide and ammonia excretion after voluntary feeding in freshwater rainbow trout.

    Science.gov (United States)

    Bucking, Carol; Wood, Chris M

    2008-08-01

    We investigated the potential acid-base and nitrogenous waste excretion challenges created by voluntary feeding in freshwater rainbow trout, with particular focus on the possible occurrence of an alkaline tide (a metabolic alkalosis created by gastric HCl secretion during digestion). Plasma metabolites (glucose, urea and ammonia) were measured at various time points before and after voluntary feeding to satiation (approximately 5% body mass meal of dry commercial pellets), as was the net flux of ammonia and titratable alkalinity to the water from unfed and fed fish. Arterial blood, sampled by indwelling catheter, was examined for post-prandial effects on pH, plasma bicarbonate and plasma CO2 tension. There was no significant change in plasma glucose or urea concentrations following feeding, whereas plasma ammonia transiently increased, peaking at threefold above resting values at 12 h after the meal and remaining elevated for 24 h. The increased plasma ammonia was correlated with an increase in net ammonia excretion to the water, with fed fish significantly elevating their net ammonia excretion two- to threefold between 12 and 48 h post feeding. These parameters did not change in unfed control fish. Fed fish likewise increased the net titratable base flux to the water by approximately threefold, which resulted in a transition from a small net acid flux seen in unfed fish to a large net base flux in fed fish. Over 48 h, this resulted in a net excretion of 13 867 micromol kg(-1) more base to the external water than in unfed fish. The arterial blood exhibited a corresponding rise in pH (between 6 and 12 h) and plasma bicarbonate (between 3 and 12 h) following feeding; however, no respiratory compensation was observed, as PaCO2 remained constant. Overall, there was evidence of numerous challenges created by feeding in a freshwater teleost fish, including the occurrence of an alkaline tide, and its compensation by excretion of base to the external water. The possible

  3. Search for Coulomb-induced multifragmentation in the reaction Gd+U at 36 MeV/u

    International Nuclear Information System (INIS)

    Bacri, C.O.; Squalli, M.; Borderie, B.; Frankland, J.D.; Parlog, M.; Rivet, M.F.; Tassan-Got, L.; Charvet, J.L.

    1996-03-01

    Coulomb-induced multifragmentation is looked for in the study of the system Gd+U at 36 MeV/u with the 4π INDRA detector. Events corresponding to fragment emission from a single source were selected in the system Gd+U using global variables. Different kinematical correlations between the emitted fragments are discussed. Comparisons with simulations are used to extract the shape of the system which decays by multifragmentation, and also to obtain quantitative information about possible expansion effects. (K.A.)

  4. Safety of meglumine gadoterate (Gd-DOTA)-enhanced MRI compared to unenhanced MRI in patients with chronic kidney disease (RESCUE study)

    Energy Technology Data Exchange (ETDEWEB)

    Deray, Gilbert [Pitie Salpetriere Hospital, Department of Nephrology, Paris cedex 13 (France); Rouviere, Olivier [Hopital E. Herriot, Universite de Lyon, Hospices Civils de Lyon, Department of Urinary and Vascular Imaging, Lyon (France); Universite Lyon 1, faculte de medecine Lyon Est, Lyon (France); Bacigalupo, Lorenzo [E.O. Ospedali Galliera, Radiology Department, Genova (Italy); Maes, Bart [Heilig Hartziekenhuis Roeselare, Department of Nephrology, Roeselare (Belgium); Hannedouche, Thierry [University Hospitals, Department of Nephrology, Strasbourg (France); Vrtovsnik, Francois [Bichat Hospital, Department of Nephrology, Paris (France); Rigothier, Claire [Pellegrin Hospital, Department of Nephrology Transplantation Dialysis, Bordeaux (France); Billiouw, Jean-Marie [Onze Lieve Vrouw Ziekenhuis, Department of Nephrology, Aalst (Belgium); Campioni, Paolo [Azienda Ospedaliero-Universitaria Sant' Anna, Ferrara (Italy); Ferreiros, Joaquin [Hospital Clinico de San Carlos, Servicio de Radiodiagnostico, Madrid (Spain); Devos, Daniel [Gent University Hospital, Department of Radiology, Gent (Belgium); Alison, Daniel [Trousseau Hospital, Department of Radiology, Tours (France); Glowacki, Francois [University Hospitals, Department of Nephrology, Lille (France); Boffa, Jean-Jacques [Tenon Hospital, Department of Nephrology and Dialysis, Paris (France); Marti-Bonmati, Luis [University of Valencia, Department of Radiology, Valencia (Spain)

    2013-05-15

    To prospectively compare the renal safety of meglumine gadoterate (Gd-DOTA)-enhanced magnetic resonance imaging (MRI) to a control group (unenhanced MRI) in high-risk patients. Patients with chronic kidney disease (CKD) scheduled for MRI procedures were screened. The primary endpoint was the percentage of patients with an elevation of serum creatinine levels, measured 72 {+-} 24 h after the MRI procedure, by at least 25 % or 44.2 {mu}mol/l (0.5 mg/dl) from baseline. A non-inferiority margin of the between-group difference was set at -15 % for statistical analysis of the primary endpoint. Main secondary endpoints were the variation in serum creatinine and eGFR values between baseline and 72 {+-} 24 h after MRI and the percentage of patients with a decrease in eGFR of at least 25 % from baseline. Patients were screened for signs of nephrogenic systemic fibrosis (NSF) at 3-month follow-up. Among the 114 evaluable patients, one (1.4 %) in the Gd-DOTA-MRI group and none in the control group met the criteria of the primary endpoint [{Delta} = -1.4 %, 95%CI = (-7.9 %; 6.7 %)]. Non-inferiority was therefore demonstrated (P = 0.001). No clinically significant differences were observed between groups for the secondary endpoints. No serious safety events (including NSF) were noted. Meglumine gadoterate did not affect renal function and was a safe contrast agent in patients with CKD. (orig.)

  5. Safety of meglumine gadoterate (Gd-DOTA)-enhanced MRI compared to unenhanced MRI in patients with chronic kidney disease (RESCUE study)

    International Nuclear Information System (INIS)

    Deray, Gilbert; Rouviere, Olivier; Bacigalupo, Lorenzo; Maes, Bart; Hannedouche, Thierry; Vrtovsnik, Francois; Rigothier, Claire; Billiouw, Jean-Marie; Campioni, Paolo; Ferreiros, Joaquin; Devos, Daniel; Alison, Daniel; Glowacki, Francois; Boffa, Jean-Jacques; Marti-Bonmati, Luis

    2013-01-01

    To prospectively compare the renal safety of meglumine gadoterate (Gd-DOTA)-enhanced magnetic resonance imaging (MRI) to a control group (unenhanced MRI) in high-risk patients. Patients with chronic kidney disease (CKD) scheduled for MRI procedures were screened. The primary endpoint was the percentage of patients with an elevation of serum creatinine levels, measured 72 ± 24 h after the MRI procedure, by at least 25 % or 44.2 μmol/l (0.5 mg/dl) from baseline. A non-inferiority margin of the between-group difference was set at -15 % for statistical analysis of the primary endpoint. Main secondary endpoints were the variation in serum creatinine and eGFR values between baseline and 72 ± 24 h after MRI and the percentage of patients with a decrease in eGFR of at least 25 % from baseline. Patients were screened for signs of nephrogenic systemic fibrosis (NSF) at 3-month follow-up. Among the 114 evaluable patients, one (1.4 %) in the Gd-DOTA-MRI group and none in the control group met the criteria of the primary endpoint [Δ = -1.4 %, 95%CI = (-7.9 %; 6.7 %)]. Non-inferiority was therefore demonstrated (P = 0.001). No clinically significant differences were observed between groups for the secondary endpoints. No serious safety events (including NSF) were noted. Meglumine gadoterate did not affect renal function and was a safe contrast agent in patients with CKD. (orig.)

  6. Radiation damage in CaF2: Gd

    International Nuclear Information System (INIS)

    Prado, L.

    1979-01-01

    Calcium fluoride crystals doped with Gd 3+ at four different concentrations were irradiated at room temperature. The damage produced by radiation and the primary and secondary effects as well were studied by optical spectroscopy. The increase in optical absorption (with loss of transparency) varied from sample as a function of concentration and dose. The coloration curves showed an evolution from two to three radiation damage steps when going from a pure to the most Gd 3+ concentrated sample. The obtained spectra were analysed at characteristic wave lenghts of electronic defects (photochromic centers, F and its aggregates) and of Gd 3+ and Gd 2+ defects. As a result of the radiation damage the valence change (Gd 3+ →Gd 2+ ) and its reversible character under thermal activation were directly observed. These effects were correlated with other observed effects such as the room temperature luminescence after the irradiation ceased. The non radiative F centers formation from the interaction of holes and photochromic centers was also observed and analysed. A thermal activation study of the several defects responsible for the different absorption bands was made. Values of activation energies were obtained as expected for the kind of defects involved in these processes [pt

  7. Measuring hepatic functional reserve using T1 mapping of Gd-EOB-DTPA enhanced 3T MR imaging: A preliminary study comparing with 99mTc GSA scintigraphy and signal intensity based parameters.

    Science.gov (United States)

    Nakagawa, Masataka; Namimoto, Tomohiro; Shimizu, Kie; Morita, Kosuke; Sakamoto, Fumi; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Shiraishi, Shinya; Yamashita, Yasuyuki

    2017-07-01

    To determine the utility of liver T1-mapping on gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) enhanced magnetic resonance (MR) imaging for the measurement of liver functional reserve compared with the signal intensity (SI) based parameters, technetium-99m-galactosyl serum albumin ( 99m Tc-GSA) scintigraphy and indocyanine green (ICG) clearance. This retrospective study included 111 patients (Child-Pugh-A 90; -B 21) performed with both Gd-EOB-DTPA enhanced liver MR imaging and 99m Tc-GSA (76 patients with ICG). Receiver operating characteristic (ROC) curve analysis was performed to compare diagnostic performances of T1-relaxation-time parameters [pre-(T1pre) and post-contrast (T1hb) Gd-EOB-DTPA], SI based parameters [relative enhancement (RE), liver-to-muscle-ratio (LMR), liver-to-spleen-ratio (LSR)] and 99m Tc-GSA scintigraphy blood clearance index (HH15)] for Child-Pugh classification. Pearson's correlation was used for comparisons among T1-relaxation-time parameters, SI-based parameters, HH15 and ICG. A significant difference was obtained for Child-Pugh classification with T1hb, ΔT1, all SI based parameters and HH15. T1hb had the highest AUC followed by RE, LMR, LSR, ΔT1, HH15 and T1pre. The correlation coefficients with HH15 were T1pre 0.22, T1hb 0.53, ΔT1 -0.38 of T1 relaxation parameters; RE -0.44, LMR -0.45, LSR -0.43 of SI-based parameters. T1hb was highest for correlation with HH15. The correlation coefficients with ICG were T1pre 0.29, T1hb 0.64, ΔT1 -0.42 of T1 relaxation parameters; RE -0.50, LMR -0.61, LSR -0.58 of SI-based parameters; 0.64 of HH15. Both T1hb and HH15 were highest for correlation with ICG. T1 relaxation time at post-contrast of Gd-EOB-DTPA (T1hb) was strongly correlated with ICG clearance and moderately correlated HH15 with 99m Tc-GSA. T1hb has the potential to provide robust parameter of liver functional reserve. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Sol-gel syntheses, luminescence, and energy transfer properties of α-GdB5O9:Ce(3+)/Tb(3+) phosphors.

    Science.gov (United States)

    Sun, Xiaorui; Gao, Wenliang; Yang, Tao; Cong, Rihong

    2015-02-07

    Sol-gel method was applied to prepare homogenous and highly crystalline phosphors with the formulas α-GdB5O9:xTb(3+) (0 ≤ x ≤ 1), α-Gd1-xCexB5O9 (0 ≤ x ≤ 0.40), α-GdB5O9:xCe(3+), 0.30Tb(3+) (0 ≤ x ≤ 0.15) and α-GdB5O9:0.20Ce(3+), xTb(3+) (0 ≤ x ≤ 0.10). The success of the syntheses was proved by the linear shrinkage or expansion of the cell volumes against the substitution contents. In α-GdB5O9:xTb(3+), an efficient energy transfer from Gd(3+) to Tb(3+) was observed and there was no luminescence quenching. The exceptionally high efficiency of the f-f excitations of Tb(3+) implies that these phosphors may be good green-emitting UV-LED phosphors. For α-Gd1-xCexB5O9, Ce(3+) absorbs the majority of the energy and transfers it to Gd(3+). Therefore, the co-doping of Ce(3+) and Tb(3+) leads to a significant enhancement in the green emission of Tb(3+). Our current results together with the study on α-GdB5O9:xEu(3+) in the literature indicate that α-GdB5O9 is a good phosphor host with advantages including controllable preparation, diverse cationic doping, the absence of concentration quenching, and effective energy transfer.

  9. Magnetic ordering of GdMn2

    International Nuclear Information System (INIS)

    Ouladdiaf, B.; Ritter, C.; Ballou, R.; Deportes, J.

    1999-01-01

    Complete text of publication follows. GdMn 2 crystallizes in the C15 cubic Laves phase structure. Within this structure Mn atoms lie at the vertices of regular tetrahedra stacked in the diamond arrangement connected by sharing vertices, leading to a strong geometric frustration. An antiferromagnetic magnetic order sets in below T N ∼ 105 K. It gives rise to a large magnetovolume effect (ΔV/V ∼ 1%). Thermal expansion data show two anomalies at 105 K and 35 K. The second anomaly was often interpreted as the ferromagnetic ordering of Gd sublattice. Moessbauer data indicate however, that Gd sublattice orders at T N ∼ 105 K as the Mn moments. Elastic neutron scattering measurements were performed using short wavelength neutron beam (λ = 0.5 A) on D9 at ILL. No magnetic contribution to the nuclear peaks was found excluding thereby any K = [0 0 0] component. However antiferromagnetic peaks indexed by a propagation vector [2/3 2/3 0] were observed leading to a non collinear magnetic arrangement of both Mn and Gd sublattices. The results are discussed by invoking the geometric frustration associated with the Mn atomic packing and the singlet state of the Gd ions. (author)

  10. Kinetics of Rituximab Excretion into Urine and Peritoneal Fluid in Two Patients with Nephrotic Syndrome.

    Science.gov (United States)

    Stahl, Klaus; Duong, Michelle; Schwarz, Anke; Wagner, A D; Haller, Hermann; Schiffer, Mario; Jacobs, Roland

    2017-01-01

    Clinical observations suggest that treatment of Rituximab might be less effective in patients with nephrotic range proteinuria when compared to nonnephrotic patients. It is conceivable that the reason for this is that significant amounts of Rituximab might be lost in the urine in a nephrotic patient and that these patients require a repeated or higher dosage. However, this has not been systematically studied. In this case report we describe two different patients with nephrotic range proteinuria receiving Rituximab. The first patient received Rituximab for therapy resistant cryoglobulinemic membranoproliferative glomerulonephritis and the other for second line treatment of Felty's syndrome. We employed flow cytometry to determine the amount of Rituximab excretion in both urine and peritoneal fluid specimens in these patients following administration of Rituximab. We found that a significant amount of Rituximab is lost from the circulation by excretion into the urine. Furthermore we saw a close correlation of the excretion of Rituximab to the excretion of IgG molecules suggesting selectivity of proteinuria as the determining factor of Rituximab excretion. Further larger scale clinical studies could have the potential to evaluate an optimal cut-off value of IgG urinary loss before a possible administration of Rituximab therefore contributing to a more individualized treatment approach in patients with nonselective and nephrotic range proteinuria.

  11. Postoperative Compensatory Ammonium Excretion Subsequent to Systemic Acidosis in Cardiac Patients.

    Science.gov (United States)

    Roehrborn, Friederike; Dohle, Daniel-Sebastian; Waack, Indra N; Tsagakis, Konstantinos; Jakob, Heinz; Teloh, Johanna K

    2017-01-01

    Postoperative acid-base imbalances, usually acidosis, frequently occur after cardiac surgery. In most cases, the human body, not suffering from any severe preexisting illnesses regarding lung, liver, and kidney, is capable of transient compensation and final correction. The aim of this study was to correlate the appearance of postoperatively occurring acidosis with renal ammonium excretion. Between 07/2014 and 10/2014, a total of 25 consecutive patients scheduled for elective isolated coronary artery bypass grafting with cardiopulmonary bypass were enrolled in this prospective observational study. During the operative procedure and the first two postoperative days, blood gas analyses were carried out and urine samples collected. Urine samples were analyzed for the absolute amount of ammonium. Of all patients, thirteen patients developed acidosis as an initial disturbance in the postoperative period: five of respiratory and eight of metabolic origin. Four patients with respiratory acidosis but none of those with metabolic acidosis subsequently developed a base excess > +2 mEq/L. Ammonium excretion correlated with the increase in base excess. The acidosis origin seems to have a large influence on renal compensation in terms of ammonium excretion and the possibility of an overcorrection.

  12. Assessing liver function in patients with HBV-related HCC: a comparison of T{sub 1} mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Ying; Rao, Sheng-Xiang; Chen, Caizhong; Li, Renchen; Zeng, Meng-Su [Zhongshan Hospital of Fudan University, Department of Radiology, 180 Fenglin Road, Xuhui District, Shanghai (China)

    2015-05-01

    To compare the potential of T{sub 1} mapping on gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) for assessing liver function in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). One hundred consecutive patients with known HBV-related HCCs were included. T{sub 1} relaxation time and apparent diffusion coefficient (ADC) of the liver were measured, and the reduction rate of T{sub 1} relaxation time (∇%) was calculated. T{sub 1} relaxation time measurements were compared with ADC values according to the Model for End-Stage Liver Disease (MELD) score. Hepatobiliary phase (HBP) and ∇% of T{sub 1} relaxation time measurements showed significant correlations with MELD score (rho = 0.571, p < 0.0001; rho = -0.573, p < 0.0001, respectively). HBP and ∇% of T{sub 1} relaxation time were significantly different between good (MELD ≤8) and poor liver function (MELD ≥9) (p < 0.0001 for both). Areas under the receiver operating characteristic curves (AUCs) of T{sub 1} relaxation time for HBP (AUC 0.84) and ∇% (AUC 0.82) were significantly better than for ADC (AUC 0.53; p < 0.0001). T{sub 1} mapping on Gd-EOB-DTPA-enhanced MRI showed promise for evaluating liver function in patients with HBV-related HCC, while DWI was not reliable. HBP T{sub 1} relaxation time measurement was equally accurate as ∇% measurement. (orig.)

  13. Prognosis of small hepatocellular nodules detected only at the hepatobiliary phase of Gd-EOB-DTPA-enhanced MR imaging as hypointensity in cirrhosis or chronic hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Higaki, Atsushi; Ito, Katsuyoshi; Tamada, Tsutomu; Sone, Teruki; Kanki, Akihiko; Noda, Yasufumi; Yasokawa, Kazuya; Yamamoto, Akira [Kawasaki Medical School, Department of Radiology, Kurashiki City, Okayama (Japan)

    2014-10-15

    To evaluate the prognosis of ''strict'' high-risk nodules (small hepatocellular nodules detected only in the hepatobiliary phase of initial Gd-EOB-DTPA-enhanced MR examination) in patients with cirrhosis or chronic hepatitis. The study included thirty-three patients with 60 ''strict'' high-risk nodules showing hypointensity at the hepatobiliary phase that was undetectable at the vascular phase and other conventional sequences of initial Gd-EOB-DTPA-enhanced MR imaging. These nodules were observed on follow-up MR examinations until hypervascularity was detected. The potential predictive factors for hypervascular transformation were compared between two groups (group A showing hypervascular transformation, group B not showing hypervascularization). Ten (16.7 %) of 60 ''strict'' high-risk nodules showed hypervascular transformation during follow-up periods (group A). The growth rates of the nodules in group A (6.3 ± 4.5 mm/year) were significantly higher than those in group B (3.4 ± 7.2 mm/year) (p = 0.003). Additionally, the median observation period in group A (177.5 ± 189.5 day) was significantly shorter than in group B (419 ± 372.2 day) (p = 0.045). The other predictive factors were not significantly correlated with hypervascularization. Subsets of ''strict'' high-risk nodules showed hypervascular transformation during follow-up periods in association with increased growth rates, indicating that nodule growth rate is an important predictive factor for hypervascularization. (orig.)

  14. Strongly coupled band in 140Gd

    International Nuclear Information System (INIS)

    Falla-Sotelo, F.; Oliveira, J.R.B.; Rao, M.N.

    2005-01-01

    Several high-K states are known to exist in the mass 130-140 region. For the N=74 even-even isotopes, Kπ = 8 - isomers, with lifetimes ranging from ns to ms, are known in 128 Xe, 130 Ba, 132 Ce, 134 Nd, 136 Sm, and 138 Gd[. In 140 Gd, we have observed for the first time a band also based on an Iπ = 8 - state. This could be the first case of a Kπ = 8 - state observed in an N=76 even-even isotope. The systematics of the Kπ = 8 - isomeric states in N=74 isotopes has been studied by A.M. Bruce et al. These states decay towards the K = 0 ground state band, and the transitions are K-forbidden. The 140 Gd case presents strong similarities but also some significant differences with relation to the N=74 isotopes. We propose the same configuration but with larger deformation in 140 Gd

  15. Re-dispersion and film formation of GdVO4 :  Ln3+ (Ln3+ = Dy3+, Eu3+, Sm3+, Tm3+) nanoparticles: particle size and luminescence studies.

    Science.gov (United States)

    Shanta Singh, N; Ningthoujam, R S; Phaomei, Ganngam; Singh, S Dorendrajit; Vinu, A; Vatsa, R K

    2012-04-21

    GdVO(4) : Ln(3+) (Ln(3+) = Dy(3+), Eu(3+), Sm(3+), Tm(3+)) nanoparticles are prepared by a simple chemical route at 140 °C. The crystallite size can be tuned by varying the pH of the reaction medium. Interestingly, the crystallite size is found to increase significantly when pH increases from 6 to 12. This is related to slower nucleation of the GdVO(4) formation with increase of VO(4)(3-) present in solution. The luminescence study shows an efficient energy transfer from vanadate absorption of GdVO(4) to Ln(3+) and thereby enhanced emissions are obtained. A possible reaction mechanism at different pH values is suggested in this study. As-prepared samples are well dispersed in ethanol, methanol and water, and can be incorporated into polymer films. Luminescence and its decay lifetime studies confirm the decrease in non-radiative transition probability with the increase of heat treatment temperature. Re-dispersed particles will be useful in potential applications of life science and the film will be useful in display devices.

  16. The diagnostic value of Gd-EOB-DTPA-MRI for the diagnosis of focal nodular hyperplasia: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Chong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Kim, Kyung Won; Shin, Yong Moon; Kim, Pyo Nyun [Asan Liver Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Gene Young [University of Missouri, School of Medicine, Columbia (United States); Park, Seong Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Asan Liver Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-04-01

    We aimed to systematically review the gadoxetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) findings of focal nodular hyperplasia (FNH) and its diagnostic value. A thorough literature search was conducted in Ovid-MEDLINE and EMBASE databases to identify studies evaluating Gd-EOB-DTPA-MRI findings of FNH. To evaluate the frequency of characteristic imaging findings on Gd-EOB-DTPA-MRI, pooled proportions of high/iso signal intensity (SI) on the hepatobiliary phase (HBP), arterial enhancement, high/iso SI on the portal-venous phase (PVP) or equilibrium phase (EP), and the central scar were calculated. Meta-analysis was performed to evaluate the diagnostic accuracy of high/iso SI on HBP for distinguishing FNH from hepatocellular adenoma. A review of 96 articles identified ten eligible articles with 304 patients with FNHs for meta-analysis. Pooled proportion of the Gd-EOB-DTPA-MRI findings showed that high/iso SI on the HBP, arterial enhancement, and high/iso SI on the PVP/EP were observed in 93% (95% CI, 90-97%), 99% (95% CI, 97-100%), and 97% (95% CI, 95-99%) of FNHs, respectively, while a central scar was observed in 61% of FNHs (95% CI, 47-74%). High/iso SI on the HBP was highly accurate for distinguishing FNH from hepatocellular adenoma, with a summary sensitivity of 93.9% (95% CI, 89.1-97.1%) and a specificity of 95.3% (95% CI, 88.4-98.7%). High/iso SI on the HBP of Gd-EOB-DTPA-MRI is characteristic and a prevalent finding of FNHs and can be helpful in the management of patients with FNH. (orig.)

  17. GD 358 - the demise of rotational splitting?

    International Nuclear Information System (INIS)

    Hill, J.A.

    1987-01-01

    Observations of GD 358 were obtained at the McDonald Observatory in 1982 and 1985 in order to determine its periods, stability, and rates of period change. The period structure could not be resolved, and the results indicate that GD 358 does not fit the rotational splitting model. It is suggested that if the changes in the amplitude spectra of GD 358 are due to beating of stable modes, then the number of modes must be large. 7 references

  18. A new entry in GdNCT. The nanodosimetry

    International Nuclear Information System (INIS)

    Cerullo, Nicola; Bufalino, Domenico; Esposito, Juan

    2006-01-01

    The GdNCT is a recently proposed therapy, mainly based on the action of Auger and IC electrons, generated by 157 Gd after neutron activation. The energy carried out by these electrons is limited to about 1% of total energy of the reaction, but due to high electron LET, if the emitter is bound to DNA, their action is very effective. Some Gd compounds have the property to be bound to DNA. Therefore the evaluation of the DNA damage caused by the Gd-emitted electrons is a key issue. The DNA damage is due to almost double strand breaks (DSB) in the DNA double helix chain. The dimensions concerned are of the order of 2 to 3 nm. Therefore, in the study of GdNCT, besides macro and micro, we must use the new 'nanodosimetry', based on particle interactions in the nanometric sites. A general review on GdNCT state of the art and on the nanometric Monte Carlo computing techniques, applied to a DNA model, is here presented. (author)

  19. Rheumatoid arthritis of the wrist; Dynamic Gd-DTPA enhanced MRT. Rheumatoide Arthritis des Handgelenkes; Dynamische Gd-DTPA-verstaerkte MRT

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. (Radiologische Universitaetsklinik, Bonn (Germany)); Kunze, V. (Radiologische Universitaetsklinik, Bonn (Germany)); Koch, W. (Orthopaedische Universitaetsklinik, Bonn (Germany)); Bruening, R. (Radiologische Universitaetsklinik, Bonn (Germany)); Seelos, K. (Radiologische Universitaetsklinik, Bonn (Germany)); Stroehmann, I. (Radiologische Universitaetsklinik, Bonn (Germany)); Woell, B. (Radiologische Universitaetsklinik, Bonn (Germany)); Reiser, M. (Radiologische Universitaetsklinik, Bonn (Germany))

    1993-02-01

    21 patients with rheumatoid arthritis of the wrist diagnosed according to the criteria of the American Rheumatism Association were examined by dynamic MRT before and after the i.v. injection of Gd-DTPA (0.1 mmol/kg). The results were correlated with the clinical and radiological findings. The increased signal intensity of the pannus was 1.17[+-]0.45%/sec and this differed significantly (p<0.001) from bone marrow (0.16[+-]0.11%/sec) and from muscle (0.25[+-]0.16%/sec). Blood sedimentation rate correlated with the gradient of synovial proliferation (p<0.05). There were no further statistically significant correlations between the clinical, radiological and MRT findings and the change in signal intensity from synovial proliferation as shown by dynamic MRT. (orig.)

  20. Structural, Magnetic and Microwave Properties of Nanocrystalline Ni-Co-Gd Ferrites

    Science.gov (United States)

    Nikzad, Alireza; Parvizi, Roghaieh; Rezaei, Ghasem; Vaseghi, Behrooz; Khordad, Reza

    2018-02-01

    A series of Co- and Gd-substituted NiFe2O4 ferrite nanoparticles with the formula Ni1- x Co x Fe2- y Gd y O4 (where x = 0.0-1.0 and y = 0.0-0.1) have been successfully synthesized using a hydrothermal method. X-ray diffraction and field emission scanning electron microscopy results indicated that a highly crystallized spherical ferrite nanoparticle structure was obtained along with an increase in the lattice parameters. Compositional analysis of the prepared nanoferrite powders has been carried out using energy-dispersive x-ray (EDX) spectra. The EDX analysis reveals the presence of Ni, Co, Gd and Fe elements in the specimens. Magnetization and the coercive field improved dramatically with an increase in the amount of cobalt and gadolinium added, attributed to the redistribution of cations in the spinel nanoferrite structure. Saturation magnetization and coercivity values up to 99 emu/g and 918 Oe, respectively, were measured using a vibration sample magnetometer at room temperature. Comparative microwave absorption experiments demonstrated that the reflection loss (RL) properties enhanced with increasing substitution of cations in the Ni-ferrite spinel structure for an absorber thickness of 1.8 mm. A maximum RL of - 26.7 dB was obtained for substituted Ni-Co-Gd nanoferrite with x = 1.0 and y = 0.1 at a frequency of 9.4 GHz with a bandwidth of 3.6 GHz (RL ≤ - 10 dB). Experimental results revealed that the synthesized nanoparticles possessed great potential in microwave absorption applications.

  1. The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Evrim Özmen

    2016-06-01

    Full Text Available Background: Contrast enhanced magnetic resonance cholangiography is a novel technique and promising method in demonstrating biliary tree anatomy and evaluating biliary disorders. However, to date, there are a limited number of studies that have focused on the impact of this technique. Aims: We aimed to evaluate the additional role of contrast enhanced MR cholangiography (MRC and compare contrast enhanced MRC with T2-weighted (w magnetic resonance cholangiopancreatography (MRCP in the diagnosis of biliary disorders. Study Design: Diagnostic accuracy study. Methods: The T2w-MRCP and contrast enhanced MRC sequences of 31 patients whose gold standard test results were available were scored visually for the existence of pathological findings with regard to any of the biliary diseases. Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA was used as the contrast agent. The correlation values were determined according to the statistical analysis made from those scores and the sensitivity, specificity and accuracy values of each sequence were detected as well. Results: We detected that the correlation values with gold standard methods of contrast enhanced MRC sequences were significantly higher than the ones of T2w-MRCP sequences. The correlation ratios of T2w-MRCP sequences were between 26 and 34%, while those for contrast enhanced MRC sequences were between 81 and 83% for the first reader and the correlation ratios of T2w-MRCP sequences were between 10 and 61%, whereas those of contrast enhanced MRC were between 79 and 81% for the second reader The mean sensitivity, specificity and accuracy values of T2w-MRCP sequences were 14.3-42.5%, 85-89.2% and 59.3-72.5%, respectively, while the mean sensitivity, specificity and accuracy values of contrast enhanced MRC sequences were 100%, 86.7% and 93.2-93.3%, respectively. Conclusion: We suggest that obtaining of contrast enhanced MRC sequences in addition to the T2w-MRCP can be useful in

  2. Maggot excretions inhibit biofilm formation on biomaterials.

    Science.gov (United States)

    Cazander, Gwendolyn; van de Veerdonk, Mariëlle C; Vandenbroucke-Grauls, Christina M J E; Schreurs, Marco W J; Jukema, Gerrolt N

    2010-10-01

    Biofilm-associated infections in trauma surgery are difficult to treat with conventional therapies. Therefore, it is important to develop new treatment modalities. Maggots in captured bags, which are permeable for larval excretions/secretions, aid in healing severe, infected wounds, suspect for biofilm formation. Therefore we presumed maggot excretions/secretions would reduce biofilm formation. We studied biofilm formation of Staphylococcus aureus, Staphylococcus epidermidis, Klebsiella oxytoca, Enterococcus faecalis, and Enterobacter cloacae on polyethylene, titanium, and stainless steel. We compared the quantities of biofilm formation between the bacterial species on the various biomaterials and the quantity of biofilm formation after various incubation times. Maggot excretions/secretions were added to existing biofilms to examine their effect. Comb-like models of the biomaterials, made to fit in a 96-well microtiter plate, were incubated with bacterial suspension. The formed biofilms were stained in crystal violet, which was eluted in ethanol. The optical density (at 595 nm) of the eluate was determined to quantify biofilm formation. Maggot excretions/secretions were pipetted in different concentrations to (nonstained) 7-day-old biofilms, incubated 24 hours, and finally measured. The strongest biofilms were formed by S. aureus and S. epidermidis on polyethylene and the weakest on titanium. The highest quantity of biofilm formation was reached within 7 days for both bacteria. The presence of excretions/secretions reduced biofilm formation on all biomaterials. A maximum of 92% of biofilm reduction was measured. Our observations suggest maggot excretions/secretions decrease biofilm formation and could provide a new treatment for biofilm formation on infected biomaterials.

  3. Improvement of magnetocaloric properties of Gd-Ge-Si alloys by alloying with iron

    Directory of Open Access Journals (Sweden)

    Erenc-Sędziak T.

    2013-01-01

    Full Text Available The influence of annealing of Gd5Ge2Si2Fex alloys at 1200°C and of alloying with various amount of iron on structure as well as thermal and magnetocaloric properties is investigated. It was found that annealing for 1 to 10 hours improves the entropy change, but reduces the temperature of maximum magnetocaloric effect by up to 50 K. Prolonged annealing of the Gd5Ge2Si2 alloy results in the decrease of entropy change due to the reduction of Gd5Ge2Si2 phase content. Addition of iron to the ternary alloy enhances the magnetocaloric effect, if x = 0.4 – 0.6, especially if alloying is combined with annealing at 1200°C: the peak value of the isothermal entropy change from 0 to 2 T increases from 3.5 to 11 J/kgK. Simultaneously, the temperature of maximum magnetocaloric effect drops to 250 K. The changes in magnetocaloric properties are related to the change in phase transformation from the second order for arc molten ternary alloy to first order in the case of annealed and/or alloyed with iron. The results of this study indicate that the minor addition of iron and heat treatment to Gd-Ge-Si alloys may be useful in improving the materials’ magnetocaloric properties..

  4. Gadolinium-enhanced MR imaging in evaluation of cholesteatoma

    International Nuclear Information System (INIS)

    Sugihara, M.; Sugimura, K.; Ishida, T.; Fujino, A.; Miyakuni, Y.

    1990-01-01

    It was sometimes difficult to differentiate cholesteatoma from accompanied granuloma, cholesterol granuloma, or mastoiditis on high-resolution CT. This study was designed to assess the reliability with which cholesteatoma can be differentiated from those accompanied lesions by gadolinium-enhanced MR imaging. Eight patients suspected to have cholesteatoma were evaluated with GD-DTPA-enhanced MR imaging with a 1.5-T MR imaging GE Signa unit. axial pre- and postcontrast T1-weighted (TR/TE, 600/20) and T2-weighted (TR/TE, 2,000/70) images were studied. MR imaging findings were compared with histologic findings (13 lesions), which included cholesteatoma (n = 6), granuloma (n = 4), cholesterol granuloma (n = 2), and mastoiditis (n = 1). Cholesteatoma had an intermediate to high signal intensity (SI) similar to that of granuloma on both T1- and T2-weighted images. Cholesterol granulomas showed high SI on both T1- and T2-weighted images. Mastoiditis demonstrated marked high SI on T2-weighted images. Cholesterol granuloma and mastoiditis can be distinguished from cholesteatoma or granuloma on both T1- and T2-weighted images. On Gd-DTPA-enhanced images, there was marked enhancement of all granulomas. However, no cholesteatoma enhancement was seen in all six lesions. Gd-DTPA-enhanced images were able to distinguish cholesteatoma from granuloma and to estimate the exact extent of cholesteatoma. Gd-DTPA-enhanced MR imaging is valuable in the evaluation and management of cholesteatoma

  5. Iodine excretion in school children in Copenhagen

    DEFF Research Database (Denmark)

    Rasmussen, Lone B; Kirkegaard-Klitbo, Ditte Marie; Laurberg, Peter

    2016-01-01

    INTRODUCTION: Studies of dietary habits show a high iodine intake in children in Denmark. Iodine excretion in children has not previously been assessed. Iodine excretion in adults is below the recommended threshold, and it is therefore being discussed to increase the fortification level. The main...

  6. Polyethylene glycol-covered ultra-small Gd2O3 nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning

    Science.gov (United States)

    Fortin, Marc-André; Petoral, Rodrigo M., Jr.; Söderlind, Fredrik; Klasson, A.; Engström, Maria; Veres, Teodor; Käll, Per-Olof; Uvdal, Kajsa

    2007-10-01

    The size distribution and magnetic properties of ultra-small gadolinium oxide crystals (US-Gd2O3) were studied, and the impact of polyethylene glycol capping on the relaxivity constants (r1, r2) and signal intensity with this contrast agent was investigated. Size distribution and magnetic properties of US-Gd2O3 nanocrystals were measured with a TEM and PPMS magnetometer. For relaxation studies, diethylene glycol (DEG)-capped US-Gd2O3 nanocrystals were reacted with PEG-silane (MW 5000). Suspensions were adequately dialyzed in water to eliminate traces of Gd3+ and surfactants. The particle hydrodynamic radius was measured with dynamic light scattering (DLS) and the proton relaxation times were measured with a 1.5 T MRI scanner. Parallel studies were performed with DEG-Gd2O3 and PEG-silane-SPGO (Gd2O3,DTPA and the r2/r1 ratio was 1.4. PEG-silane-SPGO gave low r1 relaxivities and high r2/r1 ratios, less compatible with positive contrast agent requirements. Higher r1 were obtained with PEG-silane in comparison to DEG-Gd2O3. Treatment of DEG-US-Gd2O3 with PEG-silane provides enhanced relaxivity while preventing aggregation of the oxide cores. This study confirms that PEG-covered Gd2O3 nanoparticles can be used for positively contrasted MR applications requiring stability, biocompatible coatings and nanocrystal functionalization.

  7. Transition to intermediate valence state and x-ray photoemission in Sm/sub 1-x/Gd/sub x/S

    International Nuclear Information System (INIS)

    Campagna, M.; Chui, S.T.; Wertheim, G.K.; Tosatti, E.

    1976-01-01

    We report a systematic x-ray photoemission study of the alloys Sm 1 /sub -//subx/Gd/subx/S for 0 2+ → Sm 3+ photoemission line shape using a model which has some similarities with the Jaccarino-Walker model for magnetic alloys. It assumes the existence of only two different kinds of Sm 2+ ions in Sm 1 /sub -//subx/Gd/subx/S for x approximately-less-than 16%. We discuss possible reasons for the fact that Gd does not show the usual clustering effects known to occur in many substitutional rare-earth alloys. Lattice-constant measurements for various substituents further illustrate the importance of electronic effects in the phase transition

  8. Two-dimensional TiO{sub 2}-based nanosheets co-modified by surface-enriched carbon dots and Gd{sub 2}O{sub 3} nanoparticles for efficient visible-light-driven photocatalysis

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Dingze, E-mail: 1005116870@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Fang, Pengfei, E-mail: fangpf@whu.edu.cn [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Ding, Junqian, E-mail: 630736958@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Yang, Minchen, E-mail: 1023635028@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Cao, Yufei, E-mail: 344541464@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Zhou, Yawei, E-mail: 769107311@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Peng, Kui, E-mail: 758007737@qq.com [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Kondamareddy, Kiran Kumar, E-mail: kokila_kkk@yahoo.co.in [Department of Physics and Key Laboratory of Artificial Micro- and Nano-Structures of Ministry of Education, Wuhan University, Wuhan 430072 (China); Liu, Min, E-mail: liumhb@126.com [State Grid Zhejiang Electric Power Research Institute, Hangzhou, Zhejiang 310007 (China)

    2017-02-28

    Highlights: • Gd-C-TNSs with high stability and recycle usability were prepared by two-pot method. • Gd{sub 2}O{sub 3} loading results in the structure changes of TNSs and increase of the Ti{sup 3+} ions. • Modified CDs leads to obvious increase of optical absorption ability and red shift. • Appropriate amount of Gd{sub 2}O{sub 3} nanoparticles and CDs improve the separation of charges. • Gd-C-TNSs exhibit excellent synergistic photocatalytic activity for Cr(VI) and RhB. - Abstract: Two-dimensional TiO{sub 2}-based nanosheets (TNSs) co-modified by surface-enriched carbon dots (CDs) and Gd{sub 2}O{sub 3} nanoparticles: (Gd-C-TNSs), capable of exhibiting visible-light-driven photo catalysis were synthesized using a two-pot hydrothermal route. The samples had a sheet-like structure, thickness of approximately 3.6 nm, large specific surface area of 240–350 cm{sup 2}/g. The CDs (2–3 nm) and Gd{sub 2}O{sub 3} nanoparticles (1–2 nm) were highly dispersed over the surface of the nanosheets. The co-modification by Gd{sub 2}O{sub 3} nanoparticles and CDs influenced the crystallinity, crystal structure, and surface area of the TNSs, and improved the visible-light absorption. Surface photocurrent and fluorescence spectral studies revealed that the photo-generated charge carrier separation efficiency could be improved by an appropriate amount of modification. A very high efficiency was obtained using 0.5 at% Gd/Ti and 3.0 g/L of CDs. The visible-light-induced photocatalytic activity is enhanced under the isolated Cr(VI) system, isolated Rhodamin B (RhB) system, and the synergism between RhB degradation and Cr(VI) reduction for the Gd-C-TNSs photocatalysts. Initially, the photocatalytic activity gradually increased with an increase in the amount of CDs, and then decreased after attaining a maximum, in the case where 0.5 at% Gd/Ti and 3.0 g/L of CDs were used. The enhancement in the photocatalytic activity was attributed to the synergetic effect of the Gd{sub 2}O

  9. Hyperfine fields at some 4d, 5d and 4f impurities in ferromagnetic GdZn and GdCd

    International Nuclear Information System (INIS)

    Kasamatsu, Y.; Kojima, K.; Hihara, T.

    1995-01-01

    Hyperfine (hf) fields at 4d (Y, Nb, Rh, Pd), 5d (Lu, Ta, Ir) and 4f (La, Nd, Sm, Eu) impurities in ferromagnetic GdZn and GdCd have been measured by NMR at 4.2 K. The local moment contributions to the hf field suggest that the impurity moments at the beginning and end of the d series are parallel and antiparallel to Gd moments, respectively. The hf results for 4f impurities are also discussed. ((orig.))

  10. Excretion of biotrace elements using the multitracer technique in mice

    International Nuclear Information System (INIS)

    Wang, X.; Wu, M.; Yin, X.M.; Zhang, X.; Li, Z.W.; Tian, J.; Sheng, X.L.

    1999-01-01

    A radioactive multitracer solution obtained from the nuclear reaction of selenium with 25 MeV/nucleon 40 Ar ions was applied to the investigation of the trace elements behavior in feces and urine of mouse. The excretion rates of 23 elements, Na, K, Rb, Mg, Ca, Sr, Ga, As, Sc, V, Cr, Mn, Co, Fe, Zn, Y, Zr, Mo, Nb, Tc, Ru, Ag and In were simultaneously detected under strictly identical experimental conditions, in order to clarify the excretion behavior of the elements in Mice. Fecal and urinary excretion rates of the elements in mice reached the highest value separately at 48 and 24 hours. The total excretion of Mo, Tc and Co within 96 hours were all larger, more than 60%. Accumulative excretion rates of Ca, Nb, Mg, Sr, V, Sc, Na, Cr, Fe, Ag, Mn and Zr were 60-30%. The total rates of Ru, K, As, Zn, Rb, Y, Ga and In were less than 30%, and low excretion. The main excretion pathway of Mo, Co, Mg, Fe and Ag was through urine, and Na, K, As and Rb were eliminated from the body also in urine. But fecal excretion of Tc, Nb, Sr, Y, Ru, and In were larger than urinary excretion, and Ca, Sc, Mn, Zr, Zn were eliminated from the body in feces. (author)

  11. Synthesis, crystal structure, and physical properties of the Gd{sub 3}BiO{sub 3} and Gd{sub 8}Bi{sub 3}O{sub 8} phases

    Energy Technology Data Exchange (ETDEWEB)

    Forbes, Scott; Yuan, Fang [Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4M1 (Canada); Kosuda, Kosuke; Kolodiazhnyi, Taras [Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Mozharivskyj, Yurij, E-mail: mozhar@mcmaster.ca [Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4M1 (Canada)

    2016-01-15

    The second and third known rare-earth bismuthide oxides, Gd{sub 3}BiO{sub 3} and Gd{sub 8}Bi{sub 3}O{sub 8}, have been discovered via high temperature reactions at 1300 °C. Like its Gd–Sb–O counterparts, the Gd{sub 3}BiO{sub 3} and Gd{sub 8}Bi{sub 3}O{sub 8} phases crystallize in the monoclinic C2/m space group, with the latter containing disordered Bi atoms along the b direction of the unit cell. Unlike the RE{sub 8}Sb{sub 3}O{sub 8} series, the formation of the Gd{sub 3}BiO{sub 3} phase does not necessarily precede the formation of Gd{sub 8}Bi{sub 3}O{sub 8}, which is likely due to the difficulty of accommodating bismuth in the RE–O framework due to its larger size. Physical property measurements performed on a pure Gd{sub 8}Bi{sub 3}O{sub 8} sample reveal semiconducting behavior. Although electronic structure calculations predict metallic behavior due to an unbalanced electron count, the semiconducting behavior originates from the Anderson localization of the Bi p states near the Fermi level as a result of atomic disorder. - Graphical abstract: Reaction of GdBi and Gd{sub 2}O{sub 3} at high temperatures yields Gd–Bi–O phases. - Highlights: • Gd{sub 3}BiO{sub 3} and Gd{sub 8}Bi{sub 3}O{sub 8}, the second and third rare-earth bismuthide oxides, have been discovered. • Gd{sub 3}BiO{sub 3} and Gd{sub 8}Bi{sub 3}O{sub 8} are isostructural with RE{sub 3}SbO{sub 3} and RE{sub 8}Sb{sub 3}O{sub 8}. • Gd{sub 8}Bi{sub 3}O{sub 8} displays semiconducting behavior despite an unbalanced electron count. • Anderson localization of Bi p states results in semiconducting behavior in Gd{sub 8}Bi{sub 3}O{sub 8}.

  12. Luminescent properties of (Y,Gd)BO3:Bi3+,RE3+ (RE=Eu, Tb) phosphor under VUV/UV excitation

    International Nuclear Information System (INIS)

    Zeng Xiaoqing; Im, Seoung-Jae; Jang, Sang-Hun; Kim, Young-Mo; Park, Hyoung-Bin; Son, Seung-Hyun; Hatanaka, Hidekazu; Kim, Gi-Young; Kim, Seul-Gi

    2006-01-01

    Bi 3+ - and RE 3+ -co-doped (Y,Gd)BO 3 phosphors were prepared and their luminescent properties under vacuum ultraviolet (VUV)/UV excitation were investigated. Strong red emission for (Y,Gd)BO 3 :Bi 3+ ,Eu 3+ and strong green emission for (Y,Gd)BO 3 :Bi 3+ ,Tb 3+ are observed under VUV excitation from 147 to 200 nm with a much broader excitation region than that of single Eu 3+ -doped or Tb 3+ -doped (Y,Gd)BO 3 phosphor. Strong emissions are also observed under UV excitation around 265 nm where as nearly no luminescence is observed for single Eu 3+ -doped or Tb 3+ -doped (Y,Gd)BO 3 . The luminescence enhancement of Bi 3+ - and RE 3+ -co-doped (Y,Gd)BO 3 phosphors is due to energy transfer from Bi 3+ ion to Eu 3+ or Tb 3+ ion not only in the VUV region but also in the UV region. Besides, host sensitization competition between Bi 3+ and Eu 3+ or Tb 3+ is also observed. The investigated phosphors may be preferable for devices with a VUV light 147-200 nm as an excitation source such as PDP or mercury-free fluorescent lamp

  13. Paramagnetic perfluorocarbon-filled albumin-(Gd-DTPA) microbubbles for the induction of focused-ultrasound-induced blood-brain barrier opening and concurrent MR and ultrasound imaging.

    Science.gov (United States)

    Liao, Ai-Ho; Liu, Hao-Li; Su, Chia-Hao; Hua, Mu-Yi; Yang, Hung-Wei; Weng, Yu-Ting; Hsu, Po-Hung; Huang, Sheng-Min; Wu, Shih-Yen; Wang, Hsin-Ell; Yen, Tzu-Chen; Li, Pai-Chi

    2012-05-07

    This paper presents new albumin-shelled Gd-DTPA microbubbles (MBs) that can concurrently serve as a dual-modality contrast agent for ultrasound (US) imaging and magnetic resonance (MR) imaging to assist blood-brain barrier (BBB) opening and detect intracerebral hemorrhage (ICH) during focused ultrasound brain drug delivery. Perfluorocarbon-filled albumin-(Gd-DTPA) MBs were prepared with a mean diameter of 2320 nm and concentration of 2.903×10(9) MBs ml(-1) using albumin-(Gd-DTPA) and by sonication with perfluorocarbon (C(3)F(8)) gas. The albumin-(Gd-DTPA) MBs were then centrifuged and the procedure was repeated until the free Gd(3+) ions were eliminated (which were detected by the xylenol orange sodium salt solution). The albumin-(Gd-DTPA) MBs were also characterized and evaluated both in vitro and in vivo by US and MR imaging. Focused US was used with the albumin-(Gd-DTPA) MBs to induce disruption of the BBB in 18 rats. BBB disruption was confirmed with contrast-enhanced T(1)-weighted turbo-spin-echo sequence MR imaging. Heavy T(2)*-weighted 3D fast low-angle shot sequence MR imaging was used to detect ICH. In vitro US imaging experiments showed that albumin-(Gd-DTPA) MBs can significantly enhance the US contrast in T(1)-, T(2)- and T(2)*-weighted MR images. The r(1) and r(2) relaxivities for Gd-DTPA were 7.69 and 21.35 s(-1)mM(-1), respectively, indicating that the MBs represent a positive contrast agent in T(1)-weighted images. In vivo MR imaging experiments on 18 rats showed that focused US combined with albumin-(Gd-DTPA) MBs can be used to both induce disruption of the BBB and detect ICH. To compare the signal intensity change between pure BBB opening and BBB opening accompanying ICH, albumin-(Gd-DTPA) MB imaging can provide a ratio of 5.14 with significant difference (p = 0.026), whereas Gd-DTPA imaging only provides a ratio of 2.13 and without significant difference (p = 0.108). The results indicate that albumin-(Gd-DTPA) MBs have potential as a US/MR dual

  14. Development and utilization of extracorporeal regional complexing hemodialysis as a means of mobilizing and enhancing the excretion of methylmercury in the dog. [N-acetylcysteine; N-acetylpenicillamine; 2,3-dimercaptosuccinic acid

    Energy Technology Data Exchange (ETDEWEB)

    Kostyniak, P.J.

    1975-01-01

    The present investigation was directed at developing and testing a new procedure for increasing methylmercury excretion in the dog. The procedure utilizes hemodialysis in conjunction with the extracorporeal reversal of protein binding of methylmercury in blood by the presence of low molecular weight sulfhydryl containing complexing agents (cysteine, N-acetylcysteine, penicillamine, N-acetylpenicillamine, 2,3-dimercaptosuccinic acid) having a high chemical affinity for methylmercury. Using such a procedure, the complexed methylmercury and the free complexing agent were found to be readily removed from blood by the dialyzer. Unlike chelation therapy, this procedure does not rely on the attainment of high systemic concentrations of complexing agent in order to attain enhanced excretion by normal routes. It rather introduces into the circulatory system a shunt designed specifically for methylmercury extraction from blood. In vitro testing of this procedure revealed that methylmercury removal from blood was dependent upon the concentration of complexing agent in blood and the dialyzer blood flow rate. In vivo testing of the procedure in the dog utilized a standard hemodialyzer with infusion of complexing agent into the arterial dialyzer blood line. The rate of methylmercury removal from the dog during the treatment procedures were as high as 400 times the excretion rate of mercury in untreated dogs.

  15. Computing distance distributions from dipolar evolution data with overtones: RIDME spectroscopy with Gd(iii)-based spin labels.

    Science.gov (United States)

    Keller, Katharina; Mertens, Valerie; Qi, Mian; Nalepa, Anna I; Godt, Adelheid; Savitsky, Anton; Jeschke, Gunnar; Yulikov, Maxim

    2017-07-21

    Extraction of distance distributions between high-spin paramagnetic centers from relaxation induced dipolar modulation enhancement (RIDME) data is affected by the presence of overtones of dipolar frequencies. As previously proposed, we account for these overtones by using a modified kernel function in Tikhonov regularization analysis. This paper analyzes the performance of such an approach on a series of model compounds with the Gd(iii)-PyMTA complex serving as paramagnetic high-spin label. We describe the calibration of the overtone coefficients for the RIDME kernel, demonstrate the accuracy of distance distributions obtained with this approach, and show that for our series of Gd-rulers RIDME technique provides more accurate distance distributions than Gd(iii)-Gd(iii) double electron-electron resonance (DEER). The analysis of RIDME data including harmonic overtones can be performed using the MATLAB-based program OvertoneAnalysis, which is available as open-source software from the web page of ETH Zurich. This approach opens a perspective for the routine use of the RIDME technique with high-spin labels in structural biology and structural studies of other soft matter.

  16. Kinetics of Rituximab Excretion into Urine and Peritoneal Fluid in Two Patients with Nephrotic Syndrome

    Directory of Open Access Journals (Sweden)

    Klaus Stahl

    2017-01-01

    Full Text Available Clinical observations suggest that treatment of Rituximab might be less effective in patients with nephrotic range proteinuria when compared to nonnephrotic patients. It is conceivable that the reason for this is that significant amounts of Rituximab might be lost in the urine in a nephrotic patient and that these patients require a repeated or higher dosage. However, this has not been systematically studied. In this case report we describe two different patients with nephrotic range proteinuria receiving Rituximab. The first patient received Rituximab for therapy resistant cryoglobulinemic membranoproliferative glomerulonephritis and the other for second line treatment of Felty’s syndrome. We employed flow cytometry to determine the amount of Rituximab excretion in both urine and peritoneal fluid specimens in these patients following administration of Rituximab. We found that a significant amount of Rituximab is lost from the circulation by excretion into the urine. Furthermore we saw a close correlation of the excretion of Rituximab to the excretion of IgG molecules suggesting selectivity of proteinuria as the determining factor of Rituximab excretion. Further larger scale clinical studies could have the potential to evaluate an optimal cut-off value of IgG urinary loss before a possible administration of Rituximab therefore contributing to a more individualized treatment approach in patients with nonselective and nephrotic range proteinuria.

  17. Experimental and theoretical study of pure and doped crystals: Gd2O2S, Gd2O2S:Eu3+ and Gd2O2S:Tb3+

    Science.gov (United States)

    Wang, Fei; Chen, Xiumin; Liu, Dachun; Yang, Bin; Dai, Yongnian

    2012-08-01

    Quantum chemistry and experimental method were used to study on pure and doped Gd2O2S crystals in this paper. The band structure and DOS diagrams of pure and doped Gd2O2S crystals which calculated by using DFT (Density Functional Theory) method were illustrated to explain the luminescent properties of impurities in crystals. The calculations of the crystal structure were finished by using the program of CASTEP (Cambridge Sequential Total Energy Package). The samples showed the characteristic emissions of Tb3+ ions with 5D4-7FJ transitions and Eu3+ ions with 5D0-7FJ transitions which emit pure green luminescence and red luminescence respectively. The experimental excitation spectra of Tb3+ and Eu3+ doped Gd2O2S are in agreement of the DOS diagrams over the explored energy range, which has allowed a better understanding of different luminescence mechanisms of Tb3+ and Eu3+ in Gd2O2S crystals.

  18. Thermodynamic stability and kinetic inertness of a Gd-DTPA bisamide complex grafted onto gold nanoparticles.

    Science.gov (United States)

    Mogilireddy, Vijetha; Déchamps-Olivier, Isabelle; Alric, Christophe; Laurent, Gautier; Laurent, Sophie; Vander Elst, Luce; Muller, Robert; Bazzi, Rana; Roux, Stéphane; Tillement, Olivier; Chuburu, Françoise

    2015-01-01

    Gold nanoparticles coated by gadolinium (III) chelates (Au@DTDTPA) where DTDTPA is a dithiolated bisamide derivative of diethylenetriamine-N,N,N',N'',N''-pentaacetic acid (DTPA), constituted contrast agents for both X-ray computed tomography and magnetic resonance imaging. In an MRI context, highly stable Gd(3+) complexes are needed for in vivo applications. Thus, knowledge of the thermodynamic stability and kinetic inertness of these chelates, when grafted onto gold nanoparticles, is crucial since bisamide DTPA chelates are usually less suited for Gd(3+) coordination than DTPA. Therefore, these parameters were evaluated by means of potentiometric titrations and relaxivity measurements. The results showed that, when the chelates were grafted onto the nanoparticle, not only their thermodynamic stability but also their kinetic inertness were improved. These positive effects were correlated to the chelate packing at the nanoparticle surface that stabilized the corresponding Gd(3+) complexes and greatly enhanced their kinetic inertness. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Fabrication and Characterization of Micro- and Nano- Gd2O3 Dispersed HDPE/EPM Composites

    International Nuclear Information System (INIS)

    Uhm, Young Rang; Kim, Jae Woo; Jun, Ji Heon; Lee, Sol; Rhee, Chang Kyu

    2010-01-01

    Hydrophobic polymer mixed with Gd 2 O 3 can be used in nuclear industry as a neutron shield because of its neutron attenuating and absorbing property, while it was reported that the smaller particles dispersed polymer composites can enhance radiation shielding efficiency compared to larger particles dispersed ones. However, preparations of such materials are difficult because of the poor dispersion of the fine particles in the polymer matrix. Surface modification of the nanoparticles is therefore required for the homogeneous dispersion of the particles in the polymer matrix. In this study, pulverization of the micro-Gd 2 O 3 particles and simultaneous surface coating of the nanoparticles by polymeric surfactant low density polyethylene (LDPE) were performed by using one-step of high energy wet ball-mill. Dispersion and neutron shielding effect of the nano- and micro-Gd 2 O 3 fillers in mixed polymer of ethylene propylene monomer (EPM) and high density polyethylene (HDPE) were examined

  20. Serial magnetic resonance imaging of acute disseminated encephalomyelitis, including evaluation of the contrast-enhancing effect on lesions by Gd-DTPA

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Matsuo, Michimasa

    1996-01-01

    Many papers on the MR features of acute disseminated encephalomyelitis (ADEM) have been published, but only a few described contrast-enhanced MRI for this disease. In this study, we analyzed serial changes in MR features and the contrast-enhancing effect on lesions in five patients (5 men, 4-19 years old) discharged with the final diagnosis of ADEM. Hyperintense lesions in brain/spinal cord were demonstrated on T2-weighted MR images in all cases, but not all lesions were enhanced by Gd-DTPA. In the follow-up study many lesions disappeared, but some lesions were enlarged and some new lesions were found. These findings suggest that, although ADEM is clinically monophasic, some cases may progress with the coexistence of reducing, vanishing, and new lesions. Some clinically acute lesions were not enhanced. This might be explained by the following reasons; lesions on various phases coexist, the damage to the blood-brain barrier in the lesions is of different degrees even if it is on the same phase, and the duration of acute phase activity is short. Additionally, some hyperintense lesions remained for a long time on T2-weighted images in spite of the absence of clinical manifestation. That hyperintense area might reflect edema caused by incomplete repair of the blood-brain barrier. From our evaluation of these five cases, MRI is not useful for the diagnosis and follow-up study of ADEM. (author)

  1. A comparative study of superdeformation in 146,147,148Gd. Possible manifestations of the pseudo-SU3 symmetry, octupole shape susceptibility and superdeformed deep-hole excitations

    International Nuclear Information System (INIS)

    Zuber, K.; Balouka, D.; Beck, F.A.; Byrski, T.; Curien, D.; France, G. de; Duchene, G.; Gehringer, C.; Haas, B.; Merdinger, J.C.; Romain, P.; Santos, D.; Styczen, J.; Vivien, J.P.; Dudek, J.; Szymanski, Z.; Werner, T.R.

    1991-01-01

    Two discrete superdeformed (SD) bands have been identified in the nucleus 147 Gd and the twin-band mechanism studied by comparison with SD results for 146,148 Gd. Theoretical interprettion in terms of nucleonic orbitals with the Woods-Saxon potential is consistent with the pseudo-spin symmetry picture and the octupole susceptibility mechanism predicted by theory. (orig.)

  2. Identification of factors associated with increased excretion of foot-and-mouth disease virus

    NARCIS (Netherlands)

    Bravo De Rueda, C.; Dekker, A.; Eble, P.L.; Jong, de M.C.M.

    2014-01-01

    We investigated which variables possibly influence the amount of foot-and-mouth disease virus (FMDV) shed in secretions and excretions by FMDV infected animals, as it is likely that the amount of FMDV shed is related to transmission risk. First, in a separate analysis of laboratory data, we showed

  3. Gd enhanced MRI in sensorineural hearing loss

    International Nuclear Information System (INIS)

    Takenaka, Mika; Tono, Tetsuya; Toyama, Katsuhiro; Kano, Kiyo; Morimitsu, Tamotsu

    1996-01-01

    The enhanced MRI hearing findings of the inner ear in 124 patients with sensorineural hearing loss were evaluated. MR images were obtained before and after the intravenous administration of gadolinium (0.1 mmol/kg). In three out of seventy-nine patients with unilateral healing loss, cochlear and/or the vestibular enhancement was noted on the symptomatic side. The positive cases included those with Ramsay-Hunt syndrome, mumps and so-called sudden deafness. Forty-five patients with bilateral hearing loss showed no enhancement within the inner ear. Although positive gadolinium enhancement of the inner ear may detect inflammatory lesions due to a viral infection, its incidence in sensorineural hearing loss, including cases of sudden deafness. seems to be extremely rare. (author)

  4. Ethosuximide: liver enzyme induction and D-glucaric acid excretion.

    Science.gov (United States)

    Gilbert, J C; Scott, A K; Galloway, D B; Petrie, J C

    1974-06-01

    1 A study has been carried out to determine if ethosuximide induces liver enzymes. 2 Ethosuximide did not affect the urinary excretion of D-glucaric acid by healthy adult subjects nor was the mean daily D-glucaric acid excretion of three epileptic children on long term ethosuximide therapy different from that of three matched controls. 3 Ethosuximide (10 mg/kg or 50 mg/kg daily) did not influence D-glucaric acid excretion or liver microsomal protein and cytochrome P450 contents of guinea pigs but at a dose of 100 mg/kg daily in rats it increased liver microsomal protein and cytochrome P450 without altering D-glucaric acid excretion. 4 These results suggest that at anticonvulsant doses ethosuximide is unlikely to induce liver enzymes. The precise relationship between D-glucaric acid excretion and liver enzyme induction remains in doubt.

  5. Optical thermometry based on green upconversion emission in Er3+/Yb3+ codoped BaGdF5 glass ceramics

    Science.gov (United States)

    Wu, Ting; Zhao, Shilong; Lei, Ruoshan; Huang, Lihui; Xu, Shiqing

    2018-02-01

    Er3+/Yb3+ codoped BaGdF5 glass ceramics have been prepared and used to develop a portable all-fiber temperature sensor based on fluorescence intensity ratio technique. XRD and TEM results affirm the generation of BaGdF5 nanocrystals in the borosilicate glass. Eu3+ ions are used as spectral probe to investigate external environment around rare earth (RE) ions. Intense green upconversion emissions from Er3+ ions are detected in the BaGdF5 glass ceramics and their intensity are enhanced about three orders of magnitude after heat treatment, which is attributed to the enrichment of RE ions in the BaGdF5 phase. Based on green upconversion emission from Er3+ ions, the temperature sensing property of the portable all-fiber temperature sensor is studied. The maximum absolute sensitivity is 15.5 × 10-4 K-1 at 567 K and the relative sensitivity is 1.28% K-1 at 298 K, respectively.

  6. Increased feeding and nutrient excretion of adult Antarctic krill, Euphausia superba, exposed to enhanced carbon dioxide (CO₂.

    Directory of Open Access Journals (Sweden)

    Grace K Saba

    Full Text Available Ocean acidification has a wide-ranging potential for impacting the physiology and metabolism of zooplankton. Sufficiently elevated CO(2 concentrations can alter internal acid-base balance, compromising homeostatic regulation and disrupting internal systems ranging from oxygen transport to ion balance. We assessed feeding and nutrient excretion rates in natural populations of the keystone species Euphausia superba (Antarctic krill by conducting a CO(2 perturbation experiment at ambient and elevated atmospheric CO(2 levels in January 2011 along the West Antarctic Peninsula (WAP. Under elevated CO(2 conditions (∼672 ppm, ingestion rates of krill averaged 78 µg C individual(-1 d(-1 and were 3.5 times higher than krill ingestion rates at ambient, present day CO(2 concentrations. Additionally, rates of ammonium, phosphate, and dissolved organic carbon (DOC excretion by krill were 1.5, 1.5, and 3.0 times higher, respectively, in the high CO(2 treatment than at ambient CO(2 concentrations. Excretion of urea, however, was ∼17% lower in the high CO(2 treatment, suggesting differences in catabolic processes of krill between treatments. Activities of key metabolic enzymes, malate dehydrogenase (MDH and lactate dehydrogenase (LDH, were consistently higher in the high CO(2 treatment. The observed shifts in metabolism are consistent with increased physiological costs associated with regulating internal acid-base equilibria. This represents an additional stress that may hamper growth and reproduction, which would negatively impact an already declining krill population along the WAP.

  7. Faraday effect in Gd3Al5O12 and Gd3Ga5O12 rare earth garnets

    International Nuclear Information System (INIS)

    Valiev, U.V.; Klochkov, A.A.; Popov, A.I.; Sokolov, Y.B.

    1989-01-01

    The dispersion of the Faraday rotation of the garnets Gd 3 Ga 5 O 12 and Gd 3 Al 5 O 12 in the 440--700-nm region in the 85--295-K temperature interval and the spectral dependence of the Faraday effect in the garnets Y 3 Ga 5 O 12 and Y 3 Al 5 O 12 for wavelengths from 250 to 700 nm are investigated. The contributions to the Faraday rotation caused by the Gd 3+ ions and the diamagnetic lattice of the garnets are separated

  8. Electronic Structure of GdCuGe Intermetallic Compound

    Science.gov (United States)

    Lukoyanov, A. V.; Knyazev, Yu. V.; Kuz'min, Yu. I.

    2018-04-01

    The electronic structure of GdCuGe intermetallic compound has been studied. Spin-polarized energy spectrum calculations have been performed by the band method with allowance for strong electron correlations in the 4 f-shell of gadolinium ions. Antiferromagnetic ordering of GdCuGe at low temperatures has been obtained in a theoretical calculation, with the value of the effective magnetic moment of gadolinium ions reproduced in fair agreement with experimental data. The electronic density of states has been analyzed. An optical conductivity spectrum has been calculated for GdCuGe; it reveals specific features that are analogous to the ones discovered previously in the GdCuSi compound with a similar hexagonal structure.

  9. Identification of acute myocardial infarction with MR imaging by using combined assessment of regional wall motion and Gd-DTPA uptake

    International Nuclear Information System (INIS)

    Roos, A. de; Matheijssen, N.A.A.; Doornbos, J.; van Dijkman, P.; Pattynama, P.; van der Wall, E.

    1990-01-01

    This paper evaluates the usefulness of MR imaging for identification of acute myocardial infarction (AMI) in clinical patients, based on the assessment of regional wall motion abnormalities in conjunction with local uptake of Gd-DTPA. Fourteen patients with proved AMI and 12 normal volunteers underwent multisection-multiphase MR imaging in the short-axis plane encompassing the entire left ventricle. Gd-DTPA (0.2 mmol/kg) was injected in all patients to enhance the infarcted region. MR cine loops of the patients and volunteers were blinded and displayed. Three experienced observers scored the cine loops in consensus as to the presence or absence of AMI, noting wall motion abnormalities and/or increased Gd-DTPA uptake

  10. CADMIUM EXCRETION IN FECES OF RATS AT EXPERIMENTAL CONDITIONS

    Directory of Open Access Journals (Sweden)

    O. A. Zemlianyi

    2014-10-01

    Full Text Available Studies demonstrated that the excretions per 1 gof rat weight inthe experimental group usually prevails over the  control group, especially in the second part of the experiment. The increase in the amount of feces in animals of the experimental group was also registered. Such processes may indicate the intense excretory processes and  increase the output of harmful  pollutants from the rats  together with overall stimulation of rat digestive activity. The higher correlations between Cd and other pollutants, namely toxic Ni and Pb (r = 0.84 and 0.91, respectively were calculated for rat feces of experimental group compared to the control. The concentration of Cd and Pb in the excretion of experimental group was maximal in the first day of the experiment, suggesting definite reaction towards rapid output of maximum amount of toxicants from rat body. Subsequently, a decrease in concentration of other pollutants demonstrated their incorporation in metabolic processes and significant accumulation in rat body (kidney and liver, or involvement of other mechanisms for neutralization and removal of intoxicants. Given the increasing amount of excretions  in the second half of the experiment, this may be a solution to this issue. The Cd output per 1 g of rat weight was maximal in the first day, followed by a rapid decline and partial restoration in second half of the experiment. Obviously, it confirms the theory of substitution mechanisms in excretion of significant amount of hazardous toxicants and shifting towards less concentrated excretions in greater amount. Thus, the correlation index between the percentage of excreted pollutant and its concentration in the excretion was 0.75. When we considered only the first 7 days this increased to 0.91 and proved that during the first stage of experiment the percentage of pollutants excretion was dependent upon its concentration in feces. Correlation between Cd output rate and excretion volumes was

  11. Influence of tropical environmental and climatic factors on the daily urinary excretion in Nigeria

    International Nuclear Information System (INIS)

    Arogunjo, A.M.; Giussani, Augusto

    2008-01-01

    Full text: The daily urinary volume excreted is very crucial in order to accurately determine the excretion rate of substance needed for bioassay monitoring purposes. The International Commission on Radiological Protection (ICRP) Publication 89 reported a worldwide reference value of daily urinary volume based on the data from the temperate environment. However, in order to gain global acceptance, it is necessary to incorporate data from all parts of the world. To the best of our knowledge the present value did not include contribution from the tropical Africa. Daily dietary habits and level of exercise are considered to contribute significantly to the daily urinary excretion in normal human subject. In addition, environmental factors such as air temperature, pressure and humidity seem to play a major contributing role in tropical environments as indicated in a preliminary work conducted with a limited number of volunteers. In order to improve the statistical significance of the study, twenty four hours urine collection from large number (> 500) of subjects was conducted. The results of the study, intra- and inter variability of urine excretion, the dependence on age, gender, working habits, and the possible influence of tropical environmental conditions on the daily urine volume will be presented and discussed. (author)

  12. Atrial Natriuretic Peptide Stimulates Dopamine Tubular Transport by Organic Cation Transporters: A Novel Mechanism to Enhance Renal Sodium Excretion

    Science.gov (United States)

    Kouyoumdzian, Nicolás M.; Rukavina Mikusic, Natalia L.; Kravetz, María C.; Lee, Brenda M.; Carranza, Andrea; Del Mauro, Julieta S.; Pandolfo, Marcela; Gironacci, Mariela M.; Gorzalczany, Susana; Toblli, Jorge E.; Fernández, Belisario E.

    2016-01-01

    The aim of this study was to demonstrate the effects of atrial natriuretic peptide (ANP) on organic cation transporters (OCTs) expression and activity, and its consequences on dopamine urinary levels, Na+, K+-ATPase activity and renal function. Male Sprague Dawley rats were infused with isotonic saline solution during 120 minutes and randomized in nine different groups: control, pargyline plus tolcapone (P+T), ANP, dopamine (DA), D-22, DA+D-22, ANP+D-22, ANP+DA and ANP+DA+D-22. Renal functional parameters were determined and urinary dopamine concentration was quantified by HPLC. Expression of OCTs and D1-receptor in membrane preparations from renal cortex tissues were determined by western blot and Na+, K+-ATPase activity was determined using in vitro enzyme assay. 3H-DA renal uptake was determined in vitro. Compared to P+T group, ANP and dopamine infusion increased diuresis, urinary sodium and dopamine excretion significantly. These effects were more pronounced in ANP+DA group and reversed by OCTs blockade by D-22, demonstrating that OCTs are implied in ANP stimulated-DA uptake and transport in renal tissues. The activity of Na+, K+-ATPase exhibited a similar fashion when it was measured in the same experimental groups. Although OCTs and D1-receptor protein expression were not modified by ANP, OCTs-dependent-dopamine tubular uptake was increased by ANP through activation of NPR-A receptor and protein kinase G as signaling pathway. This effect was reflected by an increase in urinary dopamine excretion, natriuresis, diuresis and decreased Na+, K+-ATPase activity. OCTs represent a novel target that links the activity of ANP and dopamine together in a common mechanism to enhance their natriuretic and diuretic effects. PMID:27392042

  13. The magnetic anisotropy of Gd-Y alloys

    Science.gov (United States)

    Phu Thuy, Nguyen; Verdonk, H. J.; Menovsky, A.; Franse, J. J. M.; Gersdorf, R.

    1983-02-01

    Magnetic torque curves on single crystals of Gd 1- xY x ( x ⩽ 0.1) show a reduction of the anomalous contribution that was observed in pure Gd, with increasing Y-content. Several explanations of this phenomenon are indicated in this paper.

  14. Gadolinium-enhanced MR imaging of the wrist in rheumatoid arthritis: value of fat suppression pulse sequences

    International Nuclear Information System (INIS)

    Nakahara, N.; Uetani, M.; Hayashi, K.; Kawahara, Y.; Matsumoto, T.; Oda, J.

    1996-01-01

    Objective. To determine the usefulness of fat-suppressed gadolinium (Gd)-enhanced MR imaging of the wrist in patients with rheumatoid arthritis (RA). Design and patients. Fat-suppressed Gd-enhanced T1-weighted spin-echo (SE) images were obtained and compared with other standard techniques in 38 wrists of 27 patients (22-77 years) with RA. Scoring based on the degree of synovial enhancement of each joint was developed and the total scores (J-score) were correlated with radiographic stage, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and symptomatic change in the follow-up study. Results. Synovial proliferations showed marked enhancement in all the wrists. In addition, contrast enhancement in the bone marrow and tenosynovium was seen in 36 and eight wrists respectively. Fat-suppressed Gd-enhanced T1-weighted images demonstrated these abnormalities better than other techniques. The J-scores correlated well with values of CRP (P=0.0034), but not with radiographic stages and ESR. Conclusion. Fat-suppressed Gd-enhanced T1-weighted SE images can clearly demonstrate most of the essential lesions in RA including the proliferative synovium, bone erosion, bone marrow inflammatory change, and tenosynovitis. Scoring based on the extent of Gd-enhancement of synovium can be useful in the assessment of the inflammatory status. (orig.). With 8 figs

  15. Gadolinium-enhanced MR imaging of the wrist in rheumatoid arthritis: value of fat suppression pulse sequences

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, N. [Department of Radiology, Nagasaki University School of Medicine, Sakamoto 1-7-1, Nagasaki 852 (Japan); Uetani, M. [Department of Radiology, Nagasaki University School of Medicine, Sakamoto 1-7-1, Nagasaki 852 (Japan); Hayashi, K. [Department of Radiology, Nagasaki University School of Medicine, Sakamoto 1-7-1, Nagasaki 852 (Japan); Kawahara, Y. [Department of Radiology, Nagasaki University School of Medicine, Sakamoto 1-7-1, Nagasaki 852 (Japan); Matsumoto, T. [Department of Orthopedics, Nagasaki University School of Medicine, Nagasaki (Japan); Oda, J. [Department of Orthopedics, Nagasaki University School of Medicine, Nagasaki (Japan)

    1996-10-01

    Objective. To determine the usefulness of fat-suppressed gadolinium (Gd)-enhanced MR imaging of the wrist in patients with rheumatoid arthritis (RA). Design and patients. Fat-suppressed Gd-enhanced T1-weighted spin-echo (SE) images were obtained and compared with other standard techniques in 38 wrists of 27 patients (22-77 years) with RA. Scoring based on the degree of synovial enhancement of each joint was developed and the total scores (J-score) were correlated with radiographic stage, C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and symptomatic change in the follow-up study. Results. Synovial proliferations showed marked enhancement in all the wrists. In addition, contrast enhancement in the bone marrow and tenosynovium was seen in 36 and eight wrists respectively. Fat-suppressed Gd-enhanced T1-weighted images demonstrated these abnormalities better than other techniques. The J-scores correlated well with values of CRP (P=0.0034), but not with radiographic stages and ESR. Conclusion. Fat-suppressed Gd-enhanced T1-weighted SE images can clearly demonstrate most of the essential lesions in RA including the proliferative synovium, bone erosion, bone marrow inflammatory change, and tenosynovitis. Scoring based on the extent of Gd-enhancement of synovium can be useful in the assessment of the inflammatory status. (orig.). With 8 figs.

  16. Dynamic gadolinium-enhanced MRI evaluation of porcine femoral head ischemia and reperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [Clinic for Orthopaedics and Sports Traumatology, Dreifaltigkeits-Krankenhaus GmbH, Aachener Str. 445-449, 50933 Koeln (Germany); Drescher, W. [Department of Orthopaedics, Christian Albrechts University, Kiel (Germany); Becker, C. [Department of Orthopaedics, Heinrich Heine University, Duesseldorf (Germany); Sangill, R.; Stoedkilde-Joergensen, H. [Institute for Magnetic Resonance Imaging Tomography, University of Aarhus, Skejby Hospital, Aarhus (Denmark); Heydthausen, M. [Computing Center, Heinrich Heine University, Duesseldorf (Germany); Hansen, E.S.; Buenger, C. [Spine Section, Department of Orthopaedics, University of Aarhus (Denmark)

    2003-02-01

    To examine the potential of gadolinium (Gd)-enhanced dynamic MRI in the detection of early femoral head ischemia. Furthermore, to apply a three-compartment model to achieve a clinically applicable MR index for femoral head perfusion during the steady state and arterial hip joint tamponade.Design and materials In a porcine model femoral head perfusion was measured by radioactive tracer microspheres and by using a dynamic Gd-enhanced MRI protocol. Femoral head perfusion measurements and MRI tests were performed unilaterally before, during and after the experimentally induced ischemia of one of the hip joints. Ischemia was induced by increasing intra-articular pressure to 250 mmHg. All pigs showed ischemia of the femoral head epiphysis under hip joint tamponade followed by reperfusion to the same level as before joint tamponade. In two cases perfusion after removal of tamponade continued to be low. In dynamic MRI measurements increases in signal intensity were seen after intravenous infusion of Gd-DTPA, followed by a slow decrease in signal intensity. The signal-intensity curve during femoral head ischemia had a minor increase. Also the coefficient determined was a helpful indicator of femoral head ischemia. Femoral head blood flow as measured by microspheres fell significantly under joint tamponade. Early detection of this disturbed regional blood flow was possible using a dynamic MRI procedure. A biomathematical model resulted from the evaluation of the intervals of signal intensity over time which allows detection of bone blood flow changes at a very early stage. Using this new method earlier detection of femoral head necrosis may be possible. (orig.)

  17. Favored neutron excitations in superdeformed 147Gd

    International Nuclear Information System (INIS)

    Theisen, C.; Khadiri, N.; Vivien, J.P.; Ragnarsson, I.; Beausang, C.W.; Beck, F.A.; Belier, G.; Byrski, T.; Curien, D.; de France, G.; Disdier, D.; Duchene, G.; Finck, C.; Flibotte, S.; Gall, B.; Haas, B.; Hanine, H.; Herskind, B.; Kharraja, B.; Merdinger, J.C.; Nourreddine, A.; Nyako, B.M.; Perez, G.E.; Prevost, D.; Stezowski, O.; Rauch, V.; Rigollet, C.; Savajols, H.; Sharpey-Schafer, J.; Twin, P.J.; Wei, L.; Zuber, K.

    1996-01-01

    Four new superdeformed (SD) bands have been observed in 147 Gd using the EUROGAM II spectrometer. By comparison with 146,148,149 Gd SD bands, we use the effective alignment to assign excited band configurations, with the support of the Nilsson-Strutinsky cranking formalism. The effect of the crossing of the [642]5/2 and [651]1/2 neutron orbitals lying just below the magic N=86 SD shell gap has been investigated for the 146,147,148 Gd bands. Evidence for the [411]1/2 orbital is also given. copyright 1996 The American Physical Society

  18. Ageing effect on the magnetocaloric properties of Gd, Gd5Si1.9Ge2.1 and on the eutectic composition Gd75Cd25

    International Nuclear Information System (INIS)

    Canepa, F; Cirafici, S; Napoletano, M; Cimberle, M R; Tagliafico, L; Scarpa, F

    2008-01-01

    The ageing effects due to the interaction with typical working fluids (water and air) of magnetic refrigerant materials have been analysed for up to one year. Among the many compounds reported to exhibit a sufficiently high magnetocaloric effect, we decided to artificially age Gd, which represents the first choice high magnetocaloric element, Gd 5 Si 1.9 Ge 2.1 , belonging to the series Gd 5 (Si x Ge 4-x ) 4 which for x ∼ 0.5 displays a giant magnetocaloric effect, and finally, the eutectic Gd 75 Cd 25 alloy, presenting an almost constant adiabatic temperature rise in an interesting temperature span (260-280 K). Magnetothermal results give evidence that corrosion and corrosion/erosion processes take place with different results on the refrigerant properties of all the materials. The adiabatic temperature rise is strongly reduced due to surface oxidation which lowers thermal conduction while the effect on the refrigerant capacity Q is definitely smaller. The effects of corrosion/erosion processes are confirmed by quantitative chemical analysis performed on the refrigerant fluid before and after the ageing process. Employing working fluids with a reduced corrosive effect but with comparable thermal properties may be a viable way of avoiding corrosion damage; alternatively the use of additives to decrease the corrosive properties of the fluids is strongly suggested

  19. Urinary excretion of uranium in adult inhabitants of the Czech Republic

    International Nuclear Information System (INIS)

    Malátová, Irena; Bečková, Věra; Kotík, Lukáš

    2016-01-01

    The main aim of this study was to determine and evaluate urinary excretion of uranium in the general public of the Czech Republic. This value should serve as a baseline for distinguishing possible increase in uranium content in population living near legacy sites of mining and processing uranium ores and also to help to distinguish the proportion of the uranium content in urine among uranium miners resulting from inhaled dust. The geometric mean of the uranium concentration in urine of 74 inhabitants of the Czech Republic was 0.091 mBq/L (7.4 ng/L) with the 95% confidence interval 0.071–0.12 mBq/L (5.7–9.6 ng/L) respectively. The geometric mean of the daily excretion was 0.15 mBq/d (12.4 ng/d) with the 95% confidence interval 0.12–0.20 mBq/d (9.5–16.1 ng/d) respectively. Despite the legacy of uranium mines and plants processing uranium ore in the Czech Republic, the levels of uranium in urine and therefore, also human body content of uranium, is similar to other countries, esp. Germany, Slovenia and USA. Significant difference in the daily urinary excretion of uranium was found between individuals using public supply and private water wells as a source of drinking water. Age dependence of daily urinary excretion of uranium was not found. Mean values and their range are comparable to other countries, esp. Germany, Slovenia and USA. - Highlights: • Urinary uranium content of the inhabitants was experimentally determined. • Significant difference was found between inhabitants and uranium miners. • Higher uranium urinary content was found at users of private wells. • Dependence of urinary content on the age was not found. • The mean value and range of uranium daily excretion is similar to other countries.

  20. Gadolinium-enhanced dynamic magnetic resonance imaging with endorectal coil for local staging of rectal cancer

    International Nuclear Information System (INIS)

    Tamakawa, Mitsuharu; Kawaai, Yuriko; Shirase, Ryuji

    2010-01-01

    The aim of this study was to evaluate the accuracy of dynamic gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) with endorectal coil for assessing tumor invasion based on simple classification criteria. A total of 58 patients with operable primary rectal cancer underwent preoperative MRI. An enhancement pattern in Gd-enhanced dynamic MRI with regard to tumor penetration was clarified. Retrospectively, two observers independently scored T2-weighted MRI and T2-weighted MRI combined with Gd-enhanced dynamic MRI for tumor penetration using the following criteria: With Gd-enhanced dynamic MRI, T1 tumors showed an early enhanced line around the tumor as rim enhancement; T2 tumors appeared as black lines or double layers, as the muscularis propria kept its integrity; T3 tumors showed partial discontinuity of the muscularis propria as a dotted line and a perforated area as an interrupted line. A confidence level scoring system was used, and receiver operating characteristic curves were generated. There were no significant differences at the T1 stage. There were significant differences for observer 1 (P=0.001 for observer 1) at the T2 stage. There were significant differences for both observers (P=0.001 for observer 1 and P=0.005 for observer 2) at the T3 stage. Our criteria for Gd-enhanced dynamic MRI were effective for T3 stage tumors. (author)

  1. Improved MR imaging of head and neck tumors with use of fat suppression with and without Gd-DTPA

    International Nuclear Information System (INIS)

    Tien, R.D.; Hesselink, J.R.; Szumowski, J.; Robbins, K.T.

    1990-01-01

    This paper determines the feasibility of using MR fat-suppression techniques for tumors and lymphadenopathies of the head and neck. To date, 28 patients with various tumors and lymphadenopathies have been evaluated. All patients were studied with standard spin-echo T1-weighted images (T1WI) and T2-weighted images (T2WI), with and without fat-suppression technique. T1WI with Gd-DTPA and fat suppression was performed in 17 patients. Conventional and paired fat-suppression MR images were compared by means of a grading system. The post-Gd-DTPA fat-suppression T1WI and fat-suppression T2WI were found to be most useful. Fat-suppression T2WI were generally even better than post-Gd-DTPA fat-suppression T1WI in cases of squamous cell carcinoma, due to its medium contrast enhancement. Post-Gd-DTPA fat-suppression T1WI were more useful than fat-suppression T2WI in a case of plexiform neurofibroma, due to its fibrous component and lack of protons

  2. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  3. The impact of gender and puberty on reference values for urinary growth hormone excretion

    DEFF Research Database (Denmark)

    Main, K M; Jarden, M; Angelo, L

    1994-01-01

    for specific laboratories or require time-intensive pretreatments of the specimens. This limits the possibility for many centers to compare their patients' data with others or to establish their own reference ranges for U-GH excretion. Therefore, we investigated the performance of a commercially available kit...

  4. Interfacial exchange, magnetic coupling and magnetoresistance in ultra-thin GdN/NbN/GdN tri-layers

    Science.gov (United States)

    Takamura, Yota; Goncalves, Rafael S.; Cascales, Juan Pedro; Altinkok, Atilgan; de Araujo, Clodoaldo I. L.; Lauter, Valeria; Moodera, Jagadeesh S.; MIT Team

    Superconducting spin-valve structures with a superconductive (SC) spacer sandwiched between ferromagnetic (FM) insulating layers [Li PRL 2013, Senapati APL 2013, Zhu Nat. Mat. 2016.] are attractive since the SC and FM characteristics can mutually be controlled by the proximity effect. We investigated reactively sputtered GdN/NbN/GdN tri-layer structures with various (SC) NbN spacer thicknesses (dNbN) from superconducting to normal layers. Magnetoresistive behavior similar to GMR in metallic magnetic multilayers was observed in the tri-layers with dNbN between 5-10 monolayers (ML), where thinner NbN layers did not show superconductivity down to 4.2 K. The occurrence of GMR signal indicates the presence of a ML of FM metallic layers at the GdN/NbN interfaces. Susceptibility and transport measurements in these samples revealed that the interface layers (ILs) are ferromagnetically coupled with adjacent GdN layers. The thickness of each of the IL is deduced to be about 1.25 ML, and as a result for dNbN magnetically coupled and switched simultaneously. These findings and interfacial characterization by various techniques will be presented. Work supported by NSF and ONR Grants.

  5. Poliovirus Excretion in Children with Primary Immunodeficiency Disorders, India.

    Science.gov (United States)

    Mohanty, Madhu Chhanda; Madkaikar, Manisha Rajan; Desai, Mukesh; Taur, Prasad; Nalavade, Uma Prajwal; Sharma, Deepa Kailash; Gupta, Maya; Dalvi, Aparna; Shabrish, Snehal; Kulkarni, Manasi; Aluri, Jahnavi; Deshpande, Jagadish Mohanrao

    2017-10-01

    Prolonged excretion of poliovirus can occur in immunodeficient patients who receive oral polio vaccine, which may lead to propagation of highly divergent vaccine-derived polioviruses (VDPVs), posing a concern for global polio eradication. This study aimed to estimate the proportion of primary immunodeficient children with enterovirus infection and to identify the long-term polio/nonpolio enterovirus excreters in a tertiary care unit in Mumbai, India. During September 2014-April 2017, 151 patients received diagnoses of primary immunodeficiency (PID). We isolated 8 enteroviruses (3 polioviruses and 5 nonpolio enteroviruses) in cell culture of 105 fecal samples collected from 42 patients. Only 1 patient with severe combined immunodeficiency was identified as a long-term VDPV3 excreter (for 2 years after identification of infection). Our results show that the risk of enterovirus excretion among children in India with PID is low; however, systematic screening is necessary to identify long-term poliovirus excreters until the use of oral polio vaccine is stopped.

  6. Longitudinal follow-up with MR imaging and Gd-DTPA to assess the evolution of multiple sclerosis

    International Nuclear Information System (INIS)

    Berry, I.; Manelfe, C.; Bensemhoun, C.; Mekies, C.; Clanet, M.

    1990-01-01

    This paper assesses whether the changes seen on longitudinal follow-up with Gd-DTPA-enhanced MR imaging can help in evaluating the prognosis of multiple sclerosis (MS). Thirty patients with definite MS (relapsing-remitting in 22, progressive-chronic in eight) underwent 54 MR studies performed during disease evolution (21 relapses prior to steroid treatment, eight chronic progressions) and stability (n = 25). Another group of seven patients underwent repetitive MR imaging every 3 months (eight to 10 controls) and also during relapses. MR imaging was performed at 0.5 T with T1- and T2-weighted sequences; Gd-DTPA was injected intravenously (0.1 mmol/kg)

  7. Favored neutron excitations in superdeformed Gd-147

    NARCIS (Netherlands)

    Theisen, C; Khadiri, N; Vivien, JP; Ragnarsson, J; Beausang, CW; Beck, FA; Belier, G; Byrski, T; Curien, D; deFrance, G; Disdier, D; Duchene, G; Finck, C; Flibotte, S; Gall, B; Haas, B; Hanine, H; Herskind, B; Kharraja, B; Merdinger, JC; Nourreddine, A; Nyako, BM; Perez, GE; Prevost, D; Stezowski, O; Rauch, I; Rigollet, C; Savajols, H; SharpeySchafer, J; Twin, PJ; Wei, L; Zuber, K

    1996-01-01

    Four new superdeformed (SD) bands have been observed in Gd-147 using the EUROGAM II spectrometer. By comparison with (146,148,149),Gd SD bands, we use the effective alignment to assign excited band configurations, with the support of the Nilsson-Strutinsky cranking formalism. The effect of the

  8. The influence of some thiols on biliary excretion of methyl mercury

    International Nuclear Information System (INIS)

    Refsvik, T.

    1983-01-01

    N-Acetylpenicillamine and thiola increased biliary excretion of methyl mercury and sulfhydryl right after administration. Cysteine increased excretion of methyl mercury in bile after a temporary decrease following administration. During the interval of decreased mercury excretion biliary excretion of cysteine passed through a maximum. This indicates the existence of a common factor of the excretory systems for cysteine and methyl mercury and illustrates that cysteine cannot carry methyl mercury from liver to bile. Relatively large proportions of unchanged thiola and N-acetylpenicillamine were excreted in bile. Bile collected after administration of one of these compounds, in addition to thiola or N-acetylpenicillamine, contained other methyl mercury carrying components not present in control bile. From the experiments undertaken it cannot be stated whether these components play any role in the increased excretion of methyl mercury in bile caused by thiola and N-acetylpenicillamine. The mechanisms of increased biliary excretion of methyl mercury following administration of N-acetylpenicillamine, thiola and cysteine are discussed. (author)

  9. Modifying the size and uniformity of upconversion Yb/Er:NaGdF4 nanocrystals through alkaline-earth doping.

    Science.gov (United States)

    Lei, Lei; Chen, Daqin; Huang, Ping; Xu, Ju; Zhang, Rui; Wang, Yuansheng

    2013-11-21

    NaGdF4 is regarded as an ideal upconversion (UC) host material for lanthanide (Ln(3+)) activators because of its unique crystal structure, high Ln(3+) solubility, low phonon energy and high photochemical stability, and Ln(3+)-doped NaGdF4 UC nanocrystals (NCs) have been widely investigated as bio-imaging and magnetic resonance imaging agents recently. To realize their practical applications, controlling the size and uniformity of the monodisperse Ln(3+)-doped NaGdF4 UC NCs is highly desired. Unlike the routine routes by finely adjusting the multiple experimental parameters, herein we provide a facile and straightforward strategy to modify the size and uniformity of NaGdF4 NCs via alkaline-earth doping for the first time. With the increase of alkaline-earth doping content, the size of NaGdF4 NCs increases gradually, while the size-uniformity is still retained. We attribute this "focusing" of size distribution to the diffusion controlled growth of NaGdF4 NCs induced by alkaline-earth doping. Importantly, adopting the Ca(2+)-doped Yb/Er:NaGdF4 NCs as cores, the complete Ca/Yb/Er:NaGdF4@NaYF4 core-shell particles with excellent size-uniformity can be easily achieved. However, when taking the Yb/Er:NaGdF4 NCs without Ca(2+) doping as cores, they could not be perfectly covered by NaYF4 shells, and the obtained products are non-uniform in size. As a result, the UC emission intensity of the complete core-shell NCs increases by about 30 times in comparison with that of the cores, owing to the effective surface passivation of the Ca(2+)-doped cores and therefore protection of Er(3+) in the cores from the non-radiative decay caused by surface defects, whereas the UC intensity of the incomplete core-shell NCs is enhanced by only 3 times.

  10. Magnetic properties of the tetragonal RCuGa{sub 3} (R=Pr, Nd and Gd) single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Nagalakshmi, R., E-mail: nagaphys@yahoo.com [Department of Physics, National Institute of Technology, Tiruchirappalli 6200015 (India); Kulkarni, Ruta; Dhar, S.K.; Thamizhavel, A. [DCMPMS, Tata Institute of Fundamental Research, Mumbai 400005 (India); Krishnakumar, V. [Department of Physics, Periyar University, Salem 636011 (India); Reiffers, Marian; Čurlík, Ivan [Institute of Experimental Physics, Watsonova 47, SK-040 01 Kosice (Slovakia); Department of Physics, University of Presov, 17 Novembra 1, SK-080 01 (Slovakia); Hagemann, Hans; Lovy, Dominique [Department of Physical Chemistry, University of Geneva, Geneva (Switzerland); Nallamuthu, S. [Department of Physics, National Institute of Technology, Tiruchirappalli 6200015 (India)

    2015-07-15

    Single crystals of tetragonal RCuGa{sub 3} (R=La, Pr, Nd and Gd), with BaNiSn{sub 3} type structure (space group I4 mm), have been grown by high temperature solution growth technique using Ga as flux. Their magnetic properties were determined by heat capacity and the measurement of magnetization and electrical resistivity along [100] and [001] directions. Except LaCuGa{sub 3}, the compounds order magnetically. PrCuGa{sub 3} undergoes a ferromagnetic transition with Curie temperature of 4.6 K. NdCuGa{sub 3} shows a bulk magnetic transition at 3.3 K. The data on GdCuGa{sub 3} indicate combined characteristics of spin glass and antiferromagnetic behavior at low temperatures. From the Schottky heat capacity data the crystal electric field level energy spectra have been determined. Further we have performed temperature dependent measurements of electron spin resonance (ESR) on GdCuGa{sub 3} between 11 K and room temperature. The ESR data indicate an enhancement of magnetic fluctuations associated with spin reorientation and both homogeneous and inhomogeneous thermal broadening of the linewidth. - Highlights: • RCuGa{sub 3} (R=La, Pr, Nd and Gd) single crystals were grown by flux technique. • The compounds exhibit long range magnetic ordering. • Crystal electric field levels have been derived from Schottky heat capacity. • Electron spin resonance (ESR) studies of GdCuGa{sub 3} are also discussed.

  11. Enhancing the performance of photovoltaic cells by using down-converting KCaGd(PO4)2∶Eu3+ phosphors

    Institute of Scientific and Technical Information of China (English)

    Yen-Chi Chen; Woan-Yu Huang; Teng-Ming Chen

    2011-01-01

    The goal of this work is aimed to improve the power conversion efficiency of single crystalline silicon-based photovoltaic (PV) cells by using the solar spectral conversion principle,which employed a down-converting phosphor to convert a high-energy ultraviolet photon to the less energetic red-emitting photons to improve the spectral response of Si solar cells.In this study,the surface of silicon solar cells was coated with a red-emitting KCaGd(PO4)2∶Eu3+ phosphor by using the screen-printing technique.In addition to the investigation on the microstructure using scanning electron microscopy (SEM),we measured the short circuit current (Isc),open circuit voltage (Voc),and power conversion efficiency (η) of spectral-conversion cells and compared with those of bare solar cells as a reference.Preliminary experimental results revealed that in an optimized PV cell,an enhancement of (0.64+0.01)% (from 16.03% to 16.67%) in △η ofa Si-based PV cell was achieved.

  12. Circadian variation of urinary albumin excretion in pregnancy

    NARCIS (Netherlands)

    Douma, C. E.; van der Post, J. A.; van Acker, B. A.; Boer, K.; Koopman, M. G.

    1995-01-01

    OBJECTIVE: The hypothesis was tested that circadian variations in urinary albumin excretion of pregnant women in the third trimester of normal pregnancy are different from nonpregnant individuals. DESIGN: Circadian variability in urinary albumin excretion was studied both in pregnant women and in

  13. Serial gadolinium-enhanced magnetic resonance imaging in patients with multiple sclerosis treated with mitoxantrone

    International Nuclear Information System (INIS)

    Krapf, H.; Mauch, E.; Fetzer, U.; Laufen, H.; Kornhuber, H.H.

    1995-01-01

    Serial gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) was used to monitor the effect of mitoxantrone in ten patients with rapidly deteriorating multiple sclerosis (MS). MRI was performed as a baseline and thereafter at 1, 3, 6, 9, 12 and 24 months. The total number of Gd-enhancing lesions diminished from 169 at baseline to 10 after 1 year and to 5 after 2 years. This reduction and the percentage of follow-up MRI studies showing no Gd enhancement were more pronounced than in other MRI studies of the natural course of MS. Measured with quantitative neurological scales, only one patient showed deterioration after 2 years; nevertheless, the changes in MRI were much more marked than those observed clinically. Serial Gd-MRI therefore, seems necessary for documenting efficacy in future therapeutic trails. (orig.)

  14. Magnetic and structural studies on nanostructured Gd/Cr multilayer films

    International Nuclear Information System (INIS)

    Gadioli, G.Z.; Rouxinol, F.P.; Gelamo, R.V.; Cardoso, L.P.; Gama, S.; Bica de Moraes, M.A.

    2013-01-01

    Investigations of magnetic phases, transition temperatures and coercivity were performed in multilayered Gd/Cr films as a function of the crystalline state and morphology of the Gd layers. The films were deposited by dc magnetron sputtering at three substrate temperatures, T s , (room temperature, 300 and 500 °C). The Gd and Cr thicknesses were of 10 and 30 nm, respectively. Two series of three films were prepared. In one of the series, the films had a single Gd/Cr bilayer; in the other, 15 bilayers. The discontinuous or granular nature of the Gd layers was revealed by scanning electron microscopy Grazing incidence angle x-ray diffraction was used to investigate the crystalline state of the Gd and Cr layers. These techniques revealed that grain average size and crystalline order increase with increasing T s . From dc magnetic measurements, the co-existence of ferromagnetic and superferromagnetic phases in the Gd layers was observed, and Curie transition temperatures, T C , were determined. High coercive fields at low temperature (2 K) were measured in hysteresis cycles. Field-cooled and zero field-cooled magnetizations as functions of temperature curves exhibited, for some of the samples, a low temperature peak suggesting a freezing transition to a cluster glass state. This was confirmed by complementary ac-susceptibility measurements carried out as a function of temperature, for various frequencies of the ac field. Some results of this work – the decline in T C for decreasing Gd grain size, the high coercive field and its dependence on particle size, and the behavior of the magnetization at low temperatures for the sample deposited at room temperature – are discussed in terms of finite size and surface effects in nanosized particles. - Highlights: • Sputter-deposited Gd/Cr multilayer films with nanostructured Gd layers • Ferromagnetic and superferromagnetic phases are observed. • Ferromagnetic phase dependent of the deposition temperature • Improved

  15. Autoclave growth, magnetic, and optical properties of GdB6 nanowires

    Science.gov (United States)

    Han, Wei; Wang, Zhen; Li, Qidong; Liu, Huatao; Fan, Qinghua; Dong, Youzhong; Kuang, Quan; Zhao, Yanming

    2017-12-01

    High-quality single crystalline gadolinium hexaboride (GdB6) nanowires have been successfully prepared at very low temperatures of 200-240 °C by a high pressure solid state (HPSS) method in an autoclave with a new chemical reaction route, where Gd, H3BO3, Mg and I2 were used as raw materials. The crystal structure, morphology, valence, magnetic and optical absorption properties were investigated using XRD, FESEM, HRTEM, XPS, SQUID magnetometry and optical measurements. HRTEM images and SAED patterns reveal that the GdB6 nanowires are single crystalline with a preferred growth direction along [001]. The XPS spectrum suggests that the valence of Gd ion in GdB6 is trivalent. The effective magnetic momentum per Gd3+ in GdB6 is about 6.26 μB. The optical properties exhibit weak absorption in the visible light range, but relatively strong absorbance in the NIR and UV range. Low work function and high NIR absorption can make GdB6 nanowires a potential solar radiation shielding material for solar cells or other NIR blocking applications.

  16. Octahedral tilt independent magnetism in confined GdTiO3 films

    Science.gov (United States)

    Need, R. F.; Isaac, B. J.; Kirby, B. J.; Borchers, J. A.; Stemmer, S.; Wilson, Stephen D.

    2018-03-01

    Low temperature polarized neutron reflectometry measurements are presented, exploring the evolution of ferrimagnetism in thin GdTiO3 films embedded within a SrTiO3 matrix. In GdTiO3 films thinner than ˜4 nm, the TiO6 octahedral tilts endemic to GdTiO3 coherently relax toward the undistorted, cubic phase of SrTiO3. Our measurements indicate that the ferrimagnetic state within the GdTiO3 layers survives as these TiO6 octahedral tilts are suppressed. Furthermore, our data suggest that layers of suppressed magnetization (i.e., magnetic dead layers) develop within the GdTiO3 layer at each GdTiO3/SrTiO3 interface and explain the apparent magnetization suppression observed in thin GdTiO3 films when using volume-averaged techniques. Our data show that the low temperature magnetic moment inherent to the core GdTiO3 layers is only weakly impacted as the octahedral tilt angles are suppressed by more than 50% and the t2 g bandwidth is dramatically renormalized.

  17. Luminescent GdVO4:Eu3+ functionalized mesoporous silica nanoparticles for magnetic resonance imaging and drug delivery.

    Science.gov (United States)

    Huang, Shanshan; Cheng, Ziyong; Ma, Ping'an; Kang, Xiaojiao; Dai, Yunlu; Lin, Jun

    2013-05-14

    Luminescent GdVO4:Eu(3+) nanophosphor functionalized mesoporous silica nanoparticles (MSN) were prepared (denoted as GdVO4:Eu(3+)@MSN). The in vitro cytotoxicity tests show that the sample has good biocompatibility, which indicates that the nanocomposite could be a promising candidate for drug delivery. Flow cytometry and confocal laser scanning microscopy (CLSM) confirm that the sample can be effectively taken up by SKOV3 ovarian cancer cells and A549 lung adenocarcinoma cells. It was also shown that the GdVO4:Eu(3+)@MSN brightened the T1-weighted images and enhanced the r1 relaxivity of water protons, which suggested that they could act as T1 contrast agents for magnetic resonance (MR) imaging. It was found that the carriers present a pH-dependent drug release behavior for doxorubicin (DOX). The composites show a red emission under UV irradiation due to the GdVO4:Eu(3+) nanophosphors. Furthermore, the PL intensity of the composite shows correlation with the cumulative release of DOX. These results suggest that the composite can potentially act as a multifunctional drug carrier system with luminescent tagging, MR imaging and pH-controlled release property for DOX.

  18. μ+ depolarization in AlGd alloys

    International Nuclear Information System (INIS)

    Kohn, S.; Brown, J.A.; Heffner, R.H.; Huang, C.Y.; Kitchens, T.A. Jr.; Leon, M.; Olsen, C.E.; Schillaci, M.E.

    1979-01-01

    The μ + depolarization rate in dilute AlGd alloys containing 50 and 450 atomic ppm Gd was measured in a transverse field of 80 Oe over the temperature range 6-300 K. For both alloys, Λ increased dramatically above 200 K, reaching values of 0.69 and 0.93 μs -1 , respectively, near room temperature. The results are interpreted as providing evidence for a thermally-activated trapping mechanism. (Auth.)

  19. Evaluation of diclofenac prodrugs for enhancing transdermal delivery.

    Science.gov (United States)

    Lobo, Shabbir; Li, Henan; Farhan, Nashid; Yan, Guang

    2014-03-01

    Abstract Objective: The purpose of this study was to evaluate the approach of using diclofenac acid (DA) prodrugs for enhancing transdermal delivery. Methanol diclofenac ester (MD), ethylene glycol diclofenac ester (ED), glycerol diclofenac ester (GD) and 1,3-propylene glycol diclofenac ester (PD) were synthesized and evaluated for their physicochemical properties such as solubilities, octanol/water partition coefficients, stratum corneum/water partition coefficients, hydrolysis rates and bioconversion rates. In vitro fluxes across human epidermal membrane (HEM) in the Franz diffusion cell were determined on DA-, MD-, ED-, GD- and PD-saturated aqueous solutions. The formation of GD and ED led to the prodrugs with higher aqueous solubilities and lower partition coefficients than those of the parent drug. Prodrugs with improved aqueous solubility showed better fluxes across HEM in aqueous solution than that of the parent drug, with GD showing the highest aqueous solubility and also the highest flux. There is a linear relationship between the aqueous solubility and flux for DA, ED and PD, but GD and MD deviated from the linear line. Diclofenac prodrugs with improved hydrophilicity than the parent drug could be utilized for enhancing transdermal diclofenac delivery.

  20. Evaluation of Diclofenac Prodrugs for Enhancing Transdermal Delivery

    Science.gov (United States)

    Lobo, Shabbir; Li, Henan; Farhan, Nashid; Yan, Guang

    2016-01-01

    The purpose of this study was to evaluate the approach of using diclofenac acid (DA) prodrugs for enhancing transdermal delivery. Methanol diclofenac ester (MD), ethylene glycol diclofenac ester (ED), glycerol diclofenac ester (GD), and 1,3-propylene glycol diclofenac ester (PD) were synthesized and evaluated for their physicochemical properties such as solubilities, octanol/water partition coefficients, stratum corneum/water partition coefficients, hydrolysis rates, and bioconversion rates. In vitro fluxes across human epidermal membrane (HEM) in Franz diffusion cell were determined on DA, MD, ED, GD, and PD saturated aqueous solutions. The formation of GD and ED led to the prodrugs with higher aqueous solubilities and lower partition coefficients than those of the parent drug. Prodrugs with improved aqueous solubility showed better fluxes across HEM in aqueous solution than that of the parent drug, with GD showing the highest aqueous solubility and also the highest flux. There is a linear relationship between the aqueous solubility and flux for DA, ED and PD, but GD and MD deviated from the linear line. Overall, diclofenac prodrugs with improved hydrophilicity than the parent drug could be utilized for enhancing transdermal diclofenac delivery. PMID:24517636

  1. Single step synthesis of GdAlO3 powder

    International Nuclear Information System (INIS)

    Sinha, Amit; Nair, S.R.; Sinha, P.K.

    2011-01-01

    Research highlights: → First report on direct formation of GdAlO 3 powder using a novel combustion process. → Study of combustion characteristics of Gd(NO 3 ) 3 and Al(NO 3 ) 3 towards three fuels. → Preparation of highly sinterable GdAlO 3 powders through fuel-mixture approach. → Significant reduction in energy consumption for production of GdAlO 3 sintered body. - Abstract: A novel method for preparation of nano-crystalline gadolinium aluminate (GdAlO 3 ) powder, based on combustion synthesis, is reported. It was observed that aluminium nitrate and gadolinium nitrate exhibit different combustion characteristics with respect to urea, glycine and β-alanine. While urea was proven to be a suitable fuel for direct formation of crystalline α-Al 2 O 3 from its nitrate, glycine and β-alanine are suitable fuels for gadolinium nitrate for preparation of its oxide after combustion reaction. Based on the observed chemical characteristics of gadolinium and aluminium nitrates with respect to above mentioned fuels for the combustion reaction, the fuel mixture composition could be predicted that could lead to phase pure perovskite GdAlO 3 directly after the combustion reaction without any subsequent calcination step. The use of single fuel, on the other hand, leads to formation of amorphous precursor powders that call for subsequent calcination for the formation of crystalline GdAlO 3 . The powders produced directly after combustion reactions using fuel mixtures were found to be highly sinterable. The sintering of the powders at 1550 o C for 4 h resulted in GdAlO 3 with sintered density of more than 95%. T.D.

  2. Methane production, ruminal fermentation characteristics, nutrient digestibility, nitrogen excretion, and milk production of dairy cows fed conventional or brown midrib corn silage.

    Science.gov (United States)

    Hassanat, F; Gervais, R; Benchaar, C

    2017-04-01

    The objective of this study was to examine the effect of replacing conventional corn silage (CCS) with brown midrib corn silage (BMCS) in dairy cow diets on enteric CH 4 emission, nutrient intake, digestibility, ruminal fermentation characteristics, milk production, and N excretion. Sixteen rumen-cannulated lactating cows used in a crossover design (35-d periods) were fed (ad libitum) a total mixed ration (forage:concentrate ratio = 65:35, dry matter basis) based (59% dry matter) on either CCS or BMCS. Dry matter intake and milk yield increased when cows were fed BMCS instead of CCS. Of the milk components, only milk fat content slightly decreased when cows were fed the BMCS-based diet compared with when fed the CCS-based diet (3.81 vs. 3.92%). Compared with CCS, feeding BMCS to cows increased yields of milk protein and milk fat. Ruminal pH, protozoa numbers, total VFA concentration, and molar proportions of acetate and propionate were similar between cows fed BMCS and those fed CCS. Daily enteric CH 4 emission (g/d) was unaffected by dietary treatments, but CH 4 production expressed as a proportion of gross energy intake or on milk yield basis was lower for cows fed the BMCS-based diet than for cows fed the CCS-based diet. A decline in manure N excretion and a shift in N excretion from urine to feces were observed when BMCS replaced CCS in the diet, suggesting reduced potential of manure N volatilization. Results from this study show that improving fiber quality of corn silage in dairy cow diets through using brown midrib trait cultivar can reduce enteric CH 4 emissions as well as potential emissions of NH 3 and N 2 O from manure. However, CH 4 emissions during manure storage may increase due to excretion of degradable OM when BMCS diet is fed, which merits further investigation. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Modeling single cell antibody excretion on a biosensor

    NARCIS (Netherlands)

    Stojanovic, Ivan; Baumgartner, W.; van der Velden, T.J.G.; Terstappen, Leonardus Wendelinus Mathias Marie; Schasfoort, Richardus B.M.

    2016-01-01

    We simulated, using Comsol Multiphysics, the excretion of antibodies by single hybridoma cells and their subsequent binding on a surface plasmon resonance imaging (SPRi) sensor. The purpose was to confirm that SPRi is suitable to accurately quantify antibody (anti-EpCAM) excretion. The model showed

  4. Development of an RGB color analysis method for controlling uniformity in a long-length GdBCO coated conductor

    International Nuclear Information System (INIS)

    Kim, Tae-Jin; Lee, Jae-Hun; Lee, Yu-Ri; Moon, Seung-Hyun

    2015-01-01

    Reactive co-evaporation-deposition and reaction (RCE-DR) is a very productive GdBa 2 Cu 3 O 7−x (GdBCO) coated conductor (CC) fabrication process, which involves the fast phase conversion of an amorphous film formed by co-evaporation of three metal sources, Gd, Ba and Cu, and thus reduces the time and cost for fabrication of a GdBCO CC. We routinely use quartz crystal microbalance (QCM) to measure and control the evaporation rates of each metal source to keep a constant nominal composition of the superconducting (SC) layer. However, in the case of kilometre long GdBCO CC fabrication, evaporation rates measured by QCM do not exactly reflect deposition rates onto the substrate as source levels decrease, and thus an RGB color analysis method for quality control is designed. With this RGB color analysis method, it is possible to measure the composition of the converted SC layer very close to the actual composition, even in real time. We set up the RGB color analysis program by establishing a database, where RGB color values are matched to composition of the SC layer, and as a result of applying the program to the RCE-DR process, could fabricate high quality GdBCO CC with average critical current of 561 A cm −1 and 95% uniformity along a 1 km length. (paper)

  5. GdNCT of spontaneous canine melanoma

    International Nuclear Information System (INIS)

    Mitin, V.N.; Kulakov, V.N.; Khokhlov, V.F.

    2006-01-01

    The effectiveness of GdNCT has been studied in dogs with spontaneous melanoma of the mucousmembrane of the oral cavity patients on the NCT base at the IRT MEPhI reactor. The control group with melanomas was treated with neutrons. Fourteen canine patients were selected in the Clinic of Experimental Therapy affiliated with the RCRC RAMS. The calculation of doses has shown that the total dose of energy release depending on Gd concentration in the target can be several times higher than the dose produced by the reactor neutron beam. The calculations were carried out using the diffusion pharmacokinetic model. The gadolinium drug dipentast was administered intratumorally immediately prior to irradiation. The tumor size was estimated by measuring it in three projections. The tumor was irradiated for 60-90 minutes with a thermal neutron flux of 0.7x10 9 n/cm 2 s. The dose on tumor was 80-120 Gy, on surrounding tissues - 12-15 Gy. The treatment plan included immunotherapy with Roncoleikin in a dose of (15-10)x10 3 IE/kg. The results of GdNCT are still under observation. The results conform to those obtained by us earlier in cell cultures and inoculated experimental tumors. GdNCT is also effective in combination with immunotherapy. (author)

  6. In vivo quantification of the unidirectional influx constant for Gd-DTPA diffusion across the myocardial capillaries with MR imaging

    DEFF Research Database (Denmark)

    Larsson, H B; Stubgaard, M; Søndergaard, Lise

    1994-01-01

    The authors present an in vivo method for measuring the unidirectional influx constant (Ki) for gadolinium diethylenetriaminepentaacetic acid (DTPA) diffusion across the capillary membrane in the human myocardium with magnetic resonance imaging. Ki is related to the extraction fraction (E......) and the perfusion (F) by the equation Ki = E.F.Ki was obtained by using the longitudinal relaxation rate (R1) as a measure of the myocardial concentration of Gd-DTPA in the mathematical model for transcapillary transport across capillary membranes. Myocardial enhancement after Gd-DTPA injection was followed...

  7. Magnetic short-range order in Gd

    International Nuclear Information System (INIS)

    Child, H.R.

    1978-01-01

    The magnetic short-range order in a ferromagnetic, isotopically enriched 160 Gd metal single crystal has been investigated by quasielastic scattering of 81-meV neutrons. Since Gd behaves as an S-state ion in the metal, little anisotropy is expected in its magnetic behavior. However, the data show that there is anisotropic short-range order present over a large temperature interval both above and below T/sub C/. The data have been analyzed in terms of an Ornstein-Zernike Lorentzian form with anisotropic correlation ranges. These correlation ranges as deduced from the observed data behave normally above T/sub C/ but seem to remain constant over a fairly large interval below T/sub C/ before becoming unobservable at lower temperatures. These observations suggest that the magnetic ordering in Gd may be a more complicated phenomenon than first believed

  8. Multifunctional hydroxyapatite/Na(Y/Gd)F4:Yb3+,Er3+ composite fibers for drug delivery and dual modal imaging.

    Science.gov (United States)

    Liu, Min; Liu, Hui; Sun, Shufen; Li, Xuejiao; Zhou, Yanmin; Hou, Zhiyao; Lin, Jun

    2014-02-04

    Porous hydroxyapatite (HAp) composite fibers functionalized with up-conversion (UC) luminescent and magnetic Na(Y/Gd)F4:Yb(3+),Er(3+) nanocrystals (NCs) have been fabricated via electrospinning. After transferring hydrophobic oleic acid-capped Na(Y/Gd)F4:Yb(3+),Er(3+) NCs into aqueous solution, these water-dispersible NCs were dispersed into precursor electrospun solution containing CTAB. Na(Y/Gd)F4:Yb(3+),Er(3+)@HAp composite fibers were fabricated by the high temperature treatment of the electrospun Na(Y/Gd)F4:Yb(3+),Er(3+) NCs decorated precursor fibers. The biocompatibility test on MC 3T3-E1 cells using MTT assay shows that the HAp composite fibers have negligible cytotoxity, which reveals the HAp composite fibers could be a drug carrier for drug delivery. Because the contrast brightening is enhanced at increased concentrations of Gd(3+), the HAp composite fibers can serve as T1 magnetic resonance imaging contrast agents. In addition, the composites uptaken by MC 3T3-E1 cells present the UC luminescent emission of Er(3+) under the excitation of a 980 nm near-infrared laser. The above findings reveal Na(Y/Gd)F4:Yb(3+),Er(3+)@HAp composite fibers have potential applications in drug storage/release and magnetic resonance/UC luminescence imaging.

  9. Ganglioside GD2 in reception and transduction of cell death signal in tumor cells

    International Nuclear Information System (INIS)

    Doronin, Igor I; Vishnyakova, Polina A; Kholodenko, Irina V; Ponomarev, Eugene D; Ryazantsev, Dmitry Y; Molotkovskaya, Irina M; Kholodenko, Roman V

    2014-01-01

    Ganglioside GD2 is expressed on plasma membranes of various types of malignant cells. One of the most promising approaches for cancer immunotherapy is the treatment with monoclonal antibodies recognizing tumor-associated markers such as ganglioside GD2. It is considered that major mechanisms of anticancer activity of anti-GD2 antibodies are complement-dependent cytotoxicity and/or antibody-mediated cellular cytotoxicity. At the same time, several studies suggested that anti-GD2 antibodies are capable of direct induction of cell death of number of tumor cell lines, but it has not been investigated in details. In this study we investigated the functional role of ganglioside GD2 in the induction of cell death of multiple tumor cell lines by using GD2-specific monoclonal antibodies. Expression of GD2 on different tumor cell lines was analyzed by flow cytometry using anti-GD2 antibodies. By using HPTLC followed by densitometric analysis we measured the amount of ganglioside GD2 in total ganglioside fractions isolated from tumor cell lines. An MTT assay was performed to assess viability of GD2-positive and -negative tumor cell lines treated with anti-GD2 mAbs. Cross-reactivity of anti-GD2 mAbs with other gangliosides or other surface molecules was investigated by ELISA and flow cytometry. Inhibition of GD2 expression was achieved by using of inhibitor for ganglioside synthesis PDMP and/or siRNA for GM2/GD2 and GD3 synthases. Anti-GD2 mAbs effectively induced non-classical cell death that combined features of both apoptosis and necrosis in GD2-positive tumor cells and did not affect GD2-negative tumors. Anti-GD2 mAbs directly induced cell death, which included alteration of mitochondrial membrane potential, induction of apoptotic volume decrease and cell membrane permeability. This cytotoxic effect was mediated exclusively by specific binding of anti-GD2 antibodies with ganglioside GD2 but not with other molecules. Moreover, the level of GD2 expression correlated with

  10. Simple die pressing for making artificial holes in single-grain Gd1.5Ba2Cu3O7−y superconductors

    International Nuclear Information System (INIS)

    Kim, K-M; Park, S-D; Jun, B-H; Kim, C-J; Ko, T K

    2012-01-01

    The presence of artificial holes in single-grain REBa 2 Cu 3 O 7−y (RE123, RE: rare-earth elements) bulk superconductors can facilitate oxygen diffusion into superconducting grains through the increased surface area. In addition to the enhancement of oxygen diffusion, the mechanical properties and thermal conductivity of bulk superconductors can be improved by filling holes with a metallic conductive phase. This study presents a new and simple hole-making process for single-grain RE123 bulk superconductors. Artificial holes 3 or 5 mm in diameter were made for Gd 1.5 Ba 2 Cu 3 O 7−y (Gd1.5) powder compacts prior to the sintering/melt growth process using specially designed pressing dies. The die pressing neither induced cracking in powder compacts nor influenced thermal procedures for the Gd123 growth. Single-grain Gd1.5 bulk superconductors with holes were successfully fabricated by a top-seeded melt growth (TSMG) process using Gd1.5 powder compacts with holes. The die pressing was proven as a time-saving process in comparison with the conventional method which makes holes in sintered or melt-processed hard bodies by mechanical drilling. The detailed fabrication process of single-grain Gd1.5 bulk superconductor with holes, magnetic levitation forces, and magnetic flux density, estimated for the single-grain Gd123 bulk superconductors with holes, are reported. (paper)

  11. Crystal structure and electronic states of Co and Gd ions in a Gd0.4Sr0.6CoO2.85 single crystal

    Science.gov (United States)

    Platunov, M. S.; Dudnikov, V. A.; Orlov, Yu. S.; Kazak, N. V.; Solovyov, L. A.; Zubavichus, Ya. V.; Veligzhanin, A. A.; Dorovatovskii, P. V.; Vereshchagin, S. N.; Shaykhutdinov, K. A.; Ovchinnikov, S. G.

    2016-02-01

    X-ray diffraction and X-ray absorption near edge structure (XANES) spectra have been measured at the Co K-edge and Gd L 3-edge in GdCoO3 and Gd0.4Sr0.6CoO2.85 cobaltites. The effect of Sr substitution on the crystal structure and electronic and magnetic states of Co3+ ions in a Gd0.4Sr0.6CoO2.85 single crystal has been analyzed. The XANES measurements at the Co K-edge have not showed a noticeable shift of the absorption edge with an increase in the concentration of Sr. This indicates that the effective valence of cobalt does not change. An increase in the intensity of absorption at the Gd L 3-edge is due to an increase in the degree of hybridization of the Gd(5 d) and O(2 p) states. The effect of hole doping on the magnetic properties results in the appearance of the ferromagnetic component and in a significant increase in the magnetic moment.

  12. Strongly coupled band in {sup 140}Gd

    Energy Technology Data Exchange (ETDEWEB)

    Falla-Sotelo, F.; Oliveira, J.R.B.; Rao, M.N. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil)] (and others)

    2005-07-01

    Several high-K states are known to exist in the mass 130-140 region. For the N=74 even-even isotopes, K{pi} = 8{sup -} isomers, with lifetimes ranging from ns to ms, are known in {sup 128}Xe, {sup 130}Ba, {sup 132}Ce, {sup 134}Nd, {sup 136}Sm, and {sup 138}Gd[. In {sup 140}Gd, we have observed for the first time a band also based on an I{pi} = 8{sup -} state. This could be the first case of a K{pi} = 8{sup -} state observed in an N=76 even-even isotope. The systematics of the K{pi} = 8{sup -} isomeric states in N=74 isotopes has been studied by A.M. Bruce et al. These states decay towards the K = 0 ground state band, and the transitions are K-forbidden. The {sup 140}Gd case presents strong similarities but also some significant differences with relation to the N=74 isotopes. We propose the same configuration but with larger deformation in {sup 140}Gd.

  13. Ammonia excretion in Caenorhabditis elegans: mechanism and evidence of ammonia transport of the Rhesus protein CeRhr-1

    Science.gov (United States)

    Adlimoghaddam, Aida; Boeckstaens, Mélanie; Marini, Anna-Maria; Treberg, Jason R.; Brassinga, Ann-Karen C.; Weihrauch, Dirk

    2015-01-01

    ABSTRACT The soil-dwelling nematode Caenorhabditis elegans is a bacteriovorous animal, excreting the vast majority of its nitrogenous waste as ammonia (25.3±1.2 µmol gFW−1 day−1) and very little urea (0.21±0.004 µmol gFW−1 day−1). Although these roundworms have been used for decades as genetic model systems, very little is known about their strategy to eliminate the toxic waste product ammonia from their bodies into the environment. The current study provides evidence that ammonia is at least partially excreted via the hypodermis. Starvation reduced the ammonia excretion rates by more than half, whereas mRNA expression levels of the Rhesus protein CeRhr-2, V-type H+-ATPase (subunit A) and Na+/K+-ATPase (α-subunit) decreased correspondingly. Moreover, ammonia excretion rates were enhanced in media buffered to pH 5 and decreased at pH 9.5. Inhibitor experiments, combined with enzyme activity measurements and mRNA expression analyses, further suggested that the excretion mechanism involves the participation of the V-type H+-ATPase, carbonic anhydrase, Na+/K+-ATPase, and a functional microtubule network. These findings indicate that ammonia is excreted, not only by apical ammonia trapping, but also via vesicular transport and exocytosis. Exposure to 1 mmol l−1 NH4Cl caused a 10-fold increase in body ammonia and a tripling of ammonia excretion rates. Gene expression levels of CeRhr-1 and CeRhr-2, V-ATPase and Na+/K+-ATPase also increased significantly in response to 1 mmol l−1 NH4Cl. Importantly, a functional expression analysis showed, for the first time, ammonia transport capabilities for CeRhr-1 in a phylogenetically ancient invertebrate system, identifying these proteins as potential functional precursors to the vertebrate ammonia-transporting Rh-glycoproteins. PMID:25740900

  14. The 500 deg. C isothermal section of the Gd-Tb-Co ternary system

    International Nuclear Information System (INIS)

    Zhou, K.W.; Zhuang, Y.H.; Li, J.Q.; Zhu, Q.M.; Deng, J.Q.

    2006-01-01

    The isothermal section of the phase diagram of the Gd-Tb-Co ternary system at 500 deg. C was investigated by X-ray powder diffraction, differential thermal analysis and metallographic analysis techniques. In this isothermal section, there are nine single-phase regions, eight two-phase regions and none three-phase region. No ternary compound was found. The compounds Gd 2 Co 17 and Tb 2 Co 17 , Gd 2 Co 7 and Tb 2 Co 7 , GdCo 3 and TbCo 3 , GdCo 2 and TbCo 2 , Gd 4 Co 3 and Tb 4 Co 3 , Gd 12 Co 7 and Tb 12 Co 7 , Gd 3 Co and Tb 3 Co, Gd and Tb form a continuous series of solid solutions. In addition, we experimentally determined the vertical section of pseudobinary system and the Curie temperature of Gd 1-x Tb x Co 2 (x from 0 to 1) series alloys

  15. Pulsed Field Waveforms for Magnetization of HTS Gd-Ba-Cu-O Bulk Magnets

    International Nuclear Information System (INIS)

    Ida, T; Matsuzaki, H; Morita, E; Sakashita, H; Harada, T; Ogata, H; Kimura, Y; Miki, M; Kitano, M; Izumi, M

    2006-01-01

    Progress in pulse magnetization technique for high-temperature superconductor bulks of melt-textured RE-Ba-Cu-O with large diameter is important for the realization of power applications. We studied the pulsed power source and pulsed field waveforms to enhance to improve the magnetization properties for Gd-Ba-Cu-O bulk. The risetime and duration of pulse waveform effectively varied distribution of magnetic flux

  16. Thermal expansion of UO2-Gd2O3 fuel pellets

    International Nuclear Information System (INIS)

    Une, Katsumi

    1986-01-01

    In recent years, more consideration has been given to the application of UO 2 -Gd 2 O 3 burnable poison fuel to LWRs in order to improve the core physics and to extend the burnup. It has been known that UO 2 forms a single phase cubic fluorite type solid solution with Gd 2 O 3 up to 20 - 30 wt.% above 1300 K. The addition of Gd 2 O 3 to UO 2 lattices changes the properties of the fuel pellets. The limited data on the thermal expansion of UO 2 -Gd 2 O 3 fuel exist, but those are inconsistent. UO 2 -Gd 2 O 3 fuel pellets were fabricated, and the linear thermal expansion of UO 2 and UO 2 -(5, 8 and 10 wt.%)Gd 2 O 3 fuel pellets was measured with a differential dilatometer over the temperature range of 298 - 1973 K. A sapphire rod of 6 mm diameter and 15.5 mm length was used as the reference material. After the preheating cycle, the measurement was performed in argon atmosphere. The results for UO 2 pellets showed excellent agreement with the data in literatures. The linear thermal expansion of UO 2 -Gd 2 O 3 fuel pellets showed the increase with increasing the Gd 2 O 3 content. Consideration must be given to this excessive expansion in the fuel design of UO 2 -Gd 2 O 3 pellets. The equations for the linear thermal expansion and density of UO 2 -Gd 2 O 3 fuel pellets were derived by the method of least squares. (Kako, I.)

  17. Two new glucose 6-phosphate dehydrogenase variants associated with congenital nonspherocytic hemolytic anemia found in Japan: GD(-) Tokushima and GD(-) Tokyo.

    Science.gov (United States)

    Miwa, S; Ono, J; Nakashima, K; Abe, S; Kageoka, T

    1976-01-01

    Two new variants of glucose 6-phosphate dehydrogenase (G6PD) deficiency associated with chronic nonspherocytic hemolytic anemia were discovered in Japan. Gd(-) Tokushima was found in a 17-years-old male whose erythrocytes contained 4.4% of normal enzyme activity. Partially purified enzyme revealed a main band of normal electrophoretic mobility with additional two minor bands of different mobility; normal Km G6P, and Km NADP five-to sixfold higher than normal; normal utilization of 2-deoxy-G6P, galactose-6P, and deamino-NADP; marked thermal instability; a normal pH curve; and normal Ki NADPH. The hemolytic anemia was moderate to severe. Gd(-) Tokyo was characterized from a 15-year-old male who had chronic nonspherocytic hemolytic anemia of mild degree. The erythrocytes contained 3% of normal enzyme activity, and partially purified enzyme revealed slow electrophoretic mobility (90% of normal for both a tris-hydrochloride buffer system and a tris-EDTA-borate buffer system, and 70% of normal for a phosphate buffer system); normal Km G6P and Km NADP; normal utilization of 2-deoxy-G6P, galactose-6P, and deamino-NADP; greatly increased thermal instability; a normal pH curve; and normal Ki NADPH. These two variants are clearly different from hitherto described G6PD variants, including the Japanese variants Gd(-) Heian and Gd(-) Kyoto. The mothers of both Gd(-) Tokushima and Gd(-) Tokoyo were found to be heterozygote by an ascorbate-cyanide test.

  18. (Gd1−xErx)5Si2Ge2 compounds

    Indian Academy of Sciences (India)

    Gd metal (3 N) by arc melting, and then annealed at 1523 K (3 h). The phase, microstructure, Curie ... The temperature of magnetic transition decreases linearly from 281 K to 177 K with the increase of Er content from x = 0–0·2. ... Gd5Si2Ge2 serial compounds, different rare earth elements substituted for Gd in Gd5(Six ...

  19. Energy transfer mechanism from Gd3+ to Sm3+ in K3Gd(PO4)2:Sm3+ phosphor

    International Nuclear Information System (INIS)

    Gupta, Palvi; Bedyal, A K; Kumar, Vinay; Khajuria, Y; Sharma, Vishal; Ntwaeaborwa, O M; Swart, H C

    2015-01-01

    Undoped K 3 Gd(PO 4 ) 2 and trivalent samarium (0.5–2.5 mol%) doped K 3 Gd(PO 4 ) 2 phosphors were synthesized by the solid-state method. The phase formation, optical and luminescence properties were investigated by x-ray diffraction (XRD), diffuse reflectance (DR) spectroscopy, and photoluminescence (PL) spectroscopy. The fluorescence decay spectra of the obtained phosphors were also recorded to study the energy transfer from sensitizer (Gd 3+ ) to activator (Sm 3+ ). Energy transfer effects from sensitizer to activator caused by rare-earth ions were mainly observed in the obtained PL and lifetime spectra. The decay curves of K 3 Gd(PO 4 ) 2 phosphor with different Sm 3+ ions concentrations were found to be non-exponential and the data is well fitted with the Inokuti–Hirayama (I–H) model. The energy transfer parameters such as critical distance for the transfer processes were determined. The Commission Internationale de l’Eclairage (CIE) chromatic coordinates and color-correlated temperature were also determined for the prepared phosphor. (paper)

  20. Urinary Angiotensinogen and Renin Excretion are Associated with Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Annett Juretzko

    2017-04-01

    Full Text Available Background/Aims: Several studies sought to identify new biomarkers for chronic kidney disease (CKD. As the renal renin-angiotensin system is activated in CKD, urinary angiotensinogen or renin excretion may be suitable candidates. We tested whether urinary angiotensinogen or renin excretion is elevated in CKD and whether these parameters are associated with estimated glomerular filtration rate (eGFR. We further tested whether urinary angiotensinogen or renin excretion may convey additional information beyond that provided by albuminuria. Methods: We measured urinary and plasma angiotensinogen, renin, albumin and creatinine in 177 CKD patients from the Greifswald Approach to Individualized Medicine project and in 283 healthy controls from the Study of Health in Pomerania. The urinary excretion of specific proteins is given as protein-to-creatinine ratio. Receiver operating characteristic (ROC curves, spearman correlation coefficients and linear regression models were calculated. Results: Urinary angiotensinogen [2,511 (196-31,909 vs. 18.6 (8.3-44.0 pmol/g, *P<0.01] and renin excretion [0.311 (0.135-1.155 vs. 0.069 (0.045-0.148 pmol/g, *P<0.01] were significantly higher in CKD patients than in healthy controls. The area under the ROC curve was significantly larger when urinary angiotensinogen, renin and albumin excretion were combined than with urinary albumin excretion alone. Urinary angiotensinogen (ß-coefficient -2.405, standard error 0.117, P<0.01 and renin excretion (ß-coefficient -0.793, standard error 0.061, P<0.01 were inversely associated with eGFR. Adjustment for albuminuria, age, sex, systolic blood pressure and body mass index did not significantly affect the results. Conclusion: Urinary angiotensinogen and renin excretion are elevated in CKD patients. Both parameters are negatively associated with eGFR and these associations are independent of urinary albumin excretion. In CKD patients urinary angiotensinogen and renin excretion may