WorldWideScience

Sample records for position indicator scan

  1. Is a positive L-dimer result a sufficient indication for performing a V/Q lung scan?

    International Nuclear Information System (INIS)

    Salanitri, G.C.; Kelly, M.J.; O'Donnell, M.; Kalff, V.

    2002-01-01

    Full text: At our institution there has developed a practice of referring some patients for assessment of pulmonary embolism (PE) because of a positive L-dimer test but without standard clinical indications. Therefore this study aimed to determine whether a positive L-dimer test result by itself is a sufficient indication to perform a ventilation/perfusion V/Q study. V/Q lung scan results, L-dimer test results and appropriate radiology results of 949 consecutive patients from August 2000 to October 2001 were retrospectively reviewed. Prediction of V/Q results by L-dimer results was compared with that of clinical risk factors for PE (Risk factor + or -) These factors were dyspnoea, current deep vein thrombosis (DVT), recent orthopaedic procedure or a past history of PE/DVT, Of the 949 patients in the study population, 254 patients had an L-dimer study, with 206 positive and 48 negative L-dimer results. Helical CT was performed in 8 patients with an equivocal V/Q - 4 showed PE and 4 did not. In the 27 patients with a positive L-dimer result and PE on either V-Q scan or CT, 25 (92.6%) had additional recognised major risk factors for PE. A positive L-dimer test is a poor predictor of a positive V/Q scan compared to conventional clinical indications. Thus, a positive L-dimer test result in isolation does not constitute an appropriate indication to perform a V/Q scan. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  2. Bone scan indications in oncology

    International Nuclear Information System (INIS)

    Rocha, A.F.G. da; Marquiotti, M.

    1986-01-01

    The scintigraphic method is described and a critical analysis of its value in the research of bone metastases is presented. The method validity, the positivity of bone scan for metastases at the first examination and the preferencial distribution metastases in skeleton are related.Bone pain and the results of bone scintigram are correlated. (M.A.C.) [pt

  3. Position indication apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, T

    1964-02-24

    A plurality of magnetically operated switches are spaced equally in the hollow tube of a control rod actuating mechanism. One side of each switch is connected, via a low resistance, to a corresponding tap of a low resistance voltage divider network consisting of an equivalent number of low resistance sections with the opposite side of each switch connected to a common conducting wire A. To both ends of the voltage dividing network are connected, respectively, conducting wires B and C. Wires A, B, and C are further coupled to a fuel rod position indicator comprising a voltmeter and power source external to the control rod actuating member. The control rod actuating member is adapted to slide in the hollow tube so that switches passing a position facing a magnet secured to the lower end of the actuating member are rendered closed. Hence, the position of the control rod may be read by reading the voltage off the meter.

  4. Position indicating device

    International Nuclear Information System (INIS)

    Fellchenfeld, M.M.; Connors, G.R.

    1987-01-01

    This patent describes a position indicating device for producing an indication of the position of a displaceable structure comprising: a position representing member mounted for movement in response to displacement of the structure; sensing elements spaced apart along the defined path such that each element is associated with a respective location along the defined path; means operatively coupling the elements into respective pairs of elements, having, for each pair of elements, an output producing a signal only when a single element of its respective pair is responding to the presence of the member; signal producing members each operative for producing a signal representing a predetermined logic state in response to a predetermined input signal, the number of the signal producing members being smaller than the number of the sensing elements; and circuit means operatively connecting the outputs to the signal producing members for causing a signal at each output to produce a predetermined input signal at a corresponding signal producing member and for causing a predetermined input signal to be produced at least one the signal producing member whenever a signal is present at either one of at least two of the outputs

  5. Radar Plan Position Indicator Scope

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Radar Plan Position Indicator Scope is the collection of weather radar imagery for the period prior to the beginning of the Next Generation Radar (NEXRAD) system...

  6. Clinical indications for Thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.J.; Kelly, D.T.

    1982-01-01

    Thallium-201 myocardial perfusion scanning can assess regional myocardial perfusion non-invasively. As it is both time-consuming and expensive its use should be restricted to specific diagnostic problems. The clinical indications in known or suspected coronary artery disease are reviewed. In suspected coronary artery disease thallium scanning is most useful in patients with chest pain when the exercise ECG is uninterpretable, in men with probable angina but a negative exercise ECG, or conversely a positive exercise ECG without typical angina, and in women with probable angina and either a positive or a negative exercise ECG. In known coronary artery disease, thallium scanning may help determine the functional significance of a coronary obstruction found at angiography and may determine the site of myocardial ischaemia when multiple obstructions are present

  7. Digital, electromagnetic rod position indicator with compensation

    International Nuclear Information System (INIS)

    Feilchenfeld, M.M.; Geis, C.G.

    1985-01-01

    A digital rod position indicator having discrete coils L 0 , L 1 , L 2 ..... spaced along the travel path of an elongate magnetically permeable member stores in digital form compensation signals for automatically adjusting the location relative to the coils at which a digital output signal representative of the position of the end of the elongate member transitions from one code to the next. The appropriate compensation signal is addressed using the digital output signal and a correction factor which takes into account the direction of movement including reversals. Reference is made to the positioning of the control rods in a pressurized water reactor. (author)

  8. Economic evaluation of reprocessing - Indicative Belgian position

    International Nuclear Information System (INIS)

    1979-05-01

    This paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic evaluation of reprocessing. The indicative national position and illustrative ''phase diagram'' for Belgium is presented. Other factors which influence the Belgian viewpoint and which are not included on the phase diagram are given

  9. Economic evaluation of reprocessing. Indicative Netherlands position

    International Nuclear Information System (INIS)

    1979-05-01

    The paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic evaluation of reprocessing. The indicative national position and illustrative ''phase diagram'' for the Netherlands is presented. Two alternative scenarios have been assumed for the variation of uranium price in the future; a 2% per annum price rise and a 5% per annum price rise

  10. Economic evaluation of reprocessing - Indicative German position

    International Nuclear Information System (INIS)

    1979-05-01

    This paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic assessment of reprocessing. The indicative national position and illustrative ''phase diagram'' for the Federal Republic of Germany is presented. Advantages to be gained from the recycling of plutonium in thermal reactors are identified and it is concluded that many of these are not explicitly taken into account in the ''phase diagram''. Under the conditions pertaining in the Federal Republic of Germany thermal recycle will be economic under present day uranium prices. On the other hand the fast breeder reactor might become commercially economic around the year 2000

  11. Economic evaluation of reprocessing. Indicative UK position

    International Nuclear Information System (INIS)

    1979-05-01

    This paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic assessment of reprocessing. The indicative national position and illustrative ''phase diagram'' for the United Kingdom is presented. Under conditions pertaining in the United Kingdom the diagram suggests that: if uranium prices rise rapidly the fast reactor would become economic in the decade 1990-2000, if uranium prices rise more slowly, the fast reactor would become economic in the decade 2000-2010

  12. Economic evaluation of reprocessing - Indicative Canadian position

    International Nuclear Information System (INIS)

    1979-05-01

    This paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic evaluation of reprocessing. The indicative national position and illustrative ''phase diagram'' for Canada is presented. Three fuel cycles are considered. (1) CANDU operating on the natural uranium, once-through fuel cycle. (2) CANDU operating with low enrichment (1.2%) once-through fuel cycle. (3) CANDU operating with recycle of plutonium and depleted uranium which has been extracted from spent CANDU natural uranium fuel. The diagrams show that reprocessing and recycle of fuel can be used to reduce further the sensitivity of CANDU fuelling costs to increasing uranium ore price

  13. Comparison of supine, upright, and prone positions for liver scans

    International Nuclear Information System (INIS)

    Harolds, J.A.; Brill, A.B.; Patton, J.A.; Touya, J.J.

    1983-01-01

    We compared liver scan interpretations based on anterior images obtained in the upright, prone, and supine positions. Receiver-operating-characteristic curves were generated for three well trained observers. Results showed that reading the three different views together was more accurate than the reading of any individual image. Furthermore, interpretations based on either the prone or upright view were superior to those using the supine view alone. The prone and upright views should be used more often in liver scanning

  14. An environmental scan of quality indicators in critical care.

    Science.gov (United States)

    Valiani, Sabira; Rigal, Romain; Stelfox, Henry T; Muscedere, John; Martin, Claudio M; Dodek, Peter; Lamontagne, François; Fowler, Robert; Gheshmy, Afshan; Cook, Deborah J; Forster, Alan J; Hébert, Paul C

    2017-06-21

    We performed a directed environmental scan to identify and categorize quality indicators unique to critical care that are reported by key stakeholder organizations. We convened a panel of experts ( n = 9) to identify key organizations that are focused on quality improvement or critical care, and reviewed their online publications and website content for quality indicators. We identified quality indicators specific to the care of critically ill adult patients and then categorized them according to the Donabedian and the Institute of Medicine frameworks. We also noted the organizations' rationale for selecting these indicators and their reported evidence base. From 28 targeted organizations, we identified 222 quality indicators, 127 of which were unique. Of the 127 indicators, 63 (32.5%) were safety indicators and 61 (31.4%) were effectiveness indicators. The rationale for selecting quality indicators was supported by consensus for 58 (26.1%) of the 222 indicators and by published research evidence for 45 (20.3%); for 119 indicators (53.6%), the rationale was not reported or the reader was referred to other organizations' reports. Of the 127 unique quality indicators, 27 (21.2%) were accompanied by a formal grading of evidence, whereas for 52 (40.9%), no reference to evidence was provided. There are many quality indicators related to critical care that are available in the public domain. However, owing to a paucity of rationale for selection, supporting evidence and results of implementation, it is not clear which indicators should be adopted for use. Copyright 2017, Joule Inc. or its licensors.

  15. Economic evaluation of reprocessing. Indicative US position

    International Nuclear Information System (INIS)

    1979-05-01

    This paper, which also appears as an Appendix to the final Working Group 4 report, forms part of the overall economic assessment of reprocessing. The indicative national position and illustrative ''phase diagram'' for the United States is presented. The prospective costs of nuclear power are given for four equilibrium modes of LWR operation: once-through, 15% and 25% improved once-through and thermal recycle. For a particular representative choice of fuel cycle parameters the economic cross over at which thermal recycle becomes economic relative to a 15% improved once-through cycle is above 100/lb U 3 O 8 . Thus the US believes that for the next several decades there is no economic incentive for thermal recycle. As a planning guide the US considers that the fast reactor will not become commercialised in the US before the year 2020

  16. Relevance and indications of the bone scan - an assessment

    International Nuclear Information System (INIS)

    Reinartz, P.; Buell, U.

    2002-01-01

    Due to its high sensitivity, the bone scan is one of the most frequently performed procedures in nuclear medicine. Although specificity is often criticized as its weak point, excellent results can be achieved under employment of modern acquisition techniques like SPECT imaging and multi-phased scintigraphy or under consideration of disease-specific scintigraphic patterns. Concerning the indication for a bone scan, the former rigid diagnostic plans are more and more replaced by flexible criteria or scores. This aspect as well as the growing use of CT and MRI leads to a slight decrease in the number of performed examinations. Further competition arises by the employment of positron emission tomography for the diagnosis of pathological osseous lesions using 18 F-FDG or 18 F-fluoride ion, especially in cases of malign or inflammatory disease. Although promising results have been achieved, it is doubtful whether PET will be able to replace bone scintigraphy, especially under consideration of the economic situation of the German health care system. In conclusion it can be stated that at least in the near future the conventional bone scan will remain an essential procedure within the realm of nuclear medicine. (orig.) [de

  17. Review of design technology of control rod position indicators

    International Nuclear Information System (INIS)

    Yu, Je Yong; Huh, Hyung; Kim, Ji Ho; Kim, Jong In; Chang, Moon Hee

    1999-10-01

    An integral reactor SMART is under development at KAERI. The design characteristics of SMART are radically different from those employer in currently operating loop type water reactors in Korea. The objective of this report is to review the design technology of position indicator, and to study the various sensors which can be used in rod position indicator. Design criteria that rod position indicator should satisfy are also examined. Following position indicators are reviewed in this report. 1. Digital positioning indicator (DRPI), 2. Reed switch type position indicator (RSPT), 3. Choke sensor type position indicator, 4. Ultrasonic sensor type position indicator, 5. Comparison of each position indicator. (author)

  18. ComPoScan: Adaptive Scanning for Efficient Concurrent Communications and Positioning with 802.11

    DEFF Research Database (Denmark)

    King, Thomas; Kjærgaard, Mikkel Baun

    2008-01-01

    and by validation in several real-world deployments. Results from the emulation show that the system can realize different trade-offs by changing parameters. Furthermore, the emulation shows that the system works independently of the environment, the network card, the signal strength measurement technology......Using 802.11 concurrently for communications and positioning is problematic, especially if location-based services (e.g., indoor navigation) are concurrently executed with real-time applications (e.g., VoIP, video conferencing). Periodical scanning for measuring the signal strength interrupts......, and number and placement of access points. We also show that ComPoScan does not harm the positioning accuracy of a positioning system. By validation in several real-world deployments, we provided evidence for that the real system works as predicted by the emulation. In addition, we provide results for Com...

  19. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  20. Automated SmartPrep tracker positioning in liver MRI scans

    International Nuclear Information System (INIS)

    Goto, Takao; Kabasawa, Hiroyuki

    2013-01-01

    This paper presents a new method for automated SmartPrep tracker positioning in liver MRI scans. SmartPrep is used to monitor the contrast bolus signal in order to detect the arrival time of the bolus. Accurately placing the tracker in the aorta while viewing three planar scout images is a difficult task for the operator and is an important problem from the workflow standpoint. The development of an automated SmartPrep tracker would therefore help to improve workflow in liver MRI scans. In our proposed method, the aorta is detected using AdaBoost (which is a machine learning technique) by searching around the cerebral spinal fluid (CSF) in the spinal cord. Analysis of scout scan images showed that our detection method functioned properly for a variety of axial MR images without intensity correction. A total of 234 images reconstructed from the datasets of 64 volunteers were analyzed, and the results showed that the detection error for the aorta was approximately 3 mm. (author)

  1. Laparoscopic Meckel's diverticulumectomy following positive Meckel's diverticulum scan

    International Nuclear Information System (INIS)

    Mansberg, R.; Roberts, J.M.; Tan, B.

    2002-01-01

    Full text: Laparoscopic or 'keyhole' surgery is increasingly performed to reduce morbidity and length of hospital admissions. Laparoscopic resection of a Meckel's Diverticulum has rarely been performed as the diagnosis is only rarely made prior to surgery and most patients proceed to exploratory laparotomy. A positive Meckel's scan and subsequent laparoscopic Meckel's Diverticulumectomy is presented. A 26-year-old male tourist presented with GIT bleeding following acute alcohol ingestion. He had previously been unsuccessfully investigated in England for GIT bleeding. Following a negative gastroscopy a Meckel's Diverticulum scan was performed. The study clearly demonstrated ectopic gastrin secreting mucosa in the right iliac fossa .The following day the patient went to theatre and at laparoscopy the Meckel's diverticulum was identified and resected. Histological examination confirmed the diagnosis of a Meckel's Diverticulum. The patient returned to England 2 days later. This case illustrates how a scintigraphic diagnosis can avoid exploratory surgery and result in less invasive laparoscopic surgery. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  2. A genome scan for positive selection in thoroughbred horses.

    Science.gov (United States)

    Gu, Jingjing; Orr, Nick; Park, Stephen D; Katz, Lisa M; Sulimova, Galina; MacHugh, David E; Hill, Emmeline W

    2009-06-02

    Thoroughbred horses have been selected for exceptional racing performance resulting in system-wide structural and functional adaptations contributing to elite athletic phenotypes. Because selection has been recent and intense in a closed population that stems from a small number of founder animals Thoroughbreds represent a unique population within which to identify genomic contributions to exercise-related traits. Employing a population genetics-based hitchhiking mapping approach we performed a genome scan using 394 autosomal and X chromosome microsatellite loci and identified positively selected loci in the extreme tail-ends of the empirical distributions for (1) deviations from expected heterozygosity (Ewens-Watterson test) in Thoroughbred (n = 112) and (2) global differentiation among four geographically diverse horse populations (F(ST)). We found positively selected genomic regions in Thoroughbred enriched for phosphoinositide-mediated signalling (3.2-fold enrichment; PThoroughbred athletic phenotype. We report for the first time candidate athletic-performance genes within regions targeted by selection in Thoroughbred horses that are principally responsible for fatty acid oxidation, increased insulin sensitivity and muscle strength: ACSS1 (acyl-CoA synthetase short-chain family member 1), ACTA1 (actin, alpha 1, skeletal muscle), ACTN2 (actinin, alpha 2), ADHFE1 (alcohol dehydrogenase, iron containing, 1), MTFR1 (mitochondrial fission regulator 1), PDK4 (pyruvate dehydrogenase kinase, isozyme 4) and TNC (tenascin C). Understanding the genetic basis for exercise adaptation will be crucial for the identification of genes within the complex molecular networks underlying obesity and its consequential pathologies, such as type 2 diabetes. Therefore, we propose Thoroughbred as a novel in vivo large animal model for understanding molecular protection against metabolic disease.

  3. A Study on the Effects of Position Change on the Liver Shape on Radioisotope Scan

    International Nuclear Information System (INIS)

    Hong, Kee Suk; Choi, Du Hyok; Yang, Young Tae; Koh, Chang Soon

    1982-01-01

    For this study, the authors obtained and examined anterior views of the liver and spleen in two different positions, upright and supine, of 39 normal subjects and 20 patients with hepatic pathology by means of 99m Tc-colloid and gamma camera. This examination confirms the following findings. In general, it is shown, left lobe of the liver in upright position becomes longer in height than in supine position, while the distance between lateral margin of the liver and that of spleen becomes father in with in supine position than in upright position. The upper margin of liver moves more downward in upright position than in supine. It is noticeable that as for 5 cases with severe chronic liver disease, there is minimal alteration of the liver shape between in two positions. The comparison of the both positions for the better liver scan shows the following findings. Prominent caudate and/or left lobe are marked in the upright position in 16 cases out of the total 59, while none is found in the supine. The false cold area in lower part of the liver disappears in 7 cases in the upright position, while only one shows the disappearance of the false cold area in the supine. Left liver margin due to close contact of spleen is blurred in 3 cases in the upright position. In total 23 cases out of 59 support that the upright position is better for the liver scan, while only 4 cases support the supine position is better. These findings support two assumptions. One is that upright view can be expected more improved resolution than supine view for liver scan. Second is that minimal change of the liver shape in both views indicate the serious abnormality in the liver.

  4. Geographic analysis of forest health indicators using spatial scan statistics

    Science.gov (United States)

    John W. Coulston; Kurt H. Riitters

    2003-01-01

    Forest health analysts seek to define the location, extent, and magnitude of changes in forest ecosystems, to explain the observed changes when possible, and to draw attention to the unexplained changes for further investigation. The data come from a variety of sources including satellite images, field plot measurements, and low-altitude aerial surveys. Indicators...

  5. A genome scan for positive selection in thoroughbred horses.

    Directory of Open Access Journals (Sweden)

    Jingjing Gu

    2009-06-01

    Full Text Available Thoroughbred horses have been selected for exceptional racing performance resulting in system-wide structural and functional adaptations contributing to elite athletic phenotypes. Because selection has been recent and intense in a closed population that stems from a small number of founder animals Thoroughbreds represent a unique population within which to identify genomic contributions to exercise-related traits. Employing a population genetics-based hitchhiking mapping approach we performed a genome scan using 394 autosomal and X chromosome microsatellite loci and identified positively selected loci in the extreme tail-ends of the empirical distributions for (1 deviations from expected heterozygosity (Ewens-Watterson test in Thoroughbred (n = 112 and (2 global differentiation among four geographically diverse horse populations (F(ST. We found positively selected genomic regions in Thoroughbred enriched for phosphoinositide-mediated signalling (3.2-fold enrichment; P<0.01, insulin receptor signalling (5.0-fold enrichment; P<0.01 and lipid transport (2.2-fold enrichment; P<0.05 genes. We found a significant overrepresentation of sarcoglycan complex (11.1-fold enrichment; P<0.05 and focal adhesion pathway (1.9-fold enrichment; P<0.01 genes highlighting the role for muscle strength and integrity in the Thoroughbred athletic phenotype. We report for the first time candidate athletic-performance genes within regions targeted by selection in Thoroughbred horses that are principally responsible for fatty acid oxidation, increased insulin sensitivity and muscle strength: ACSS1 (acyl-CoA synthetase short-chain family member 1, ACTA1 (actin, alpha 1, skeletal muscle, ACTN2 (actinin, alpha 2, ADHFE1 (alcohol dehydrogenase, iron containing, 1, MTFR1 (mitochondrial fission regulator 1, PDK4 (pyruvate dehydrogenase kinase, isozyme 4 and TNC (tenascin C. Understanding the genetic basis for exercise adaptation will be crucial for the identification of genes

  6. Positive findings on bone scan in multiple myeloma

    International Nuclear Information System (INIS)

    Lin Lin

    2004-01-01

    We report a case of multiple myeloma in which the CT only shows osteolytic lesions and MRI only shows compressive fractrue, but the scan shows some interesting imaging that make us to think of multiple myeloma. (authors)

  7. Development of Seismic Resistance Position Indicator for the Integral Reactor

    International Nuclear Information System (INIS)

    Yu, Je-Yong; Huh, Hyung; Choi, Myoung-Hwan; Kim, Ji-Ho; Sohn, Dong-Seong

    2008-01-01

    The present paper is related to position sensing means and more particularly, to a magnetic position sensor using a permanent magnet and a compact arrangement of reed switches in a nuclear power plant. The reed switch position transmitter (RSPT) is used as a position indicator for the control rod in commercial nuclear power plants made by ABB-CE. But this position indicator has some problems when directly adopting it to the integral reactor. Its indicating resolution (1-1/2 inch (38.1mm)) is suitable to measure the position of a control rod which is driven by a motor having steps of 3/4 inch (19.05mm). But the Control Element Drive Mechanism (CEDM) for the integral reactor is designed to raise and lower the control rod in steps of 2mm in order to satisfy the design features of the integral reactor which are the soluble boron free operation and the use of a nuclear heating for the reactor start-up. These design features require a CEDM for the integral reactor to have a fine-step movement for a fine reactivity control. Therefore the resolution of the position indicator for the integral reactor should be achieved to sense the position of the control rod more precisely than that of the RSPT of the ABB-CE. This paper adopts seismic resistance reed switches to the position indicator in order to reduce the damages or impacts during the handling of the position indicator and earthquake. The control rod position indicator having a seismic resistance characteristic for the integral reactor was developed on the basis of the RSPT technology identified through the survey

  8. A positive 111in-pentetreotide scan in a patient with a pancreatic polypeptide secreting tumour

    International Nuclear Information System (INIS)

    Stanton, K.; Cehic, G.

    2003-01-01

    Full text: A 55-year-old male presented to our department with a known polypeptide secreting pancreatic tumour. An 111 In-pentetreotide scan (OctreoScan) was performed to determine whether the tumour expressed somatostatin receptors (SR) and thereby aid in therapy planning. 120 MBq 111 In-pentetreotide was administered intravenously. Images were acquired at 4 and 30 hours. Whole body images were acquired with spot views and tomography of the liver at 30 hours. Images showed intense uptake of the tracer in the lobular midline pancreatic mass. There was also uptake in multiple liver metastases. 111 In-pentetreotide is a synthetic somatostatin analogue and its uptake demonstrates the presence of SR on tumour cells, especially those of a neuro-endocrine nature. A 123 I Metaiodobenzylguanidine (MIBG) scan was also performed to determine whether the more widely available MIBG therapy would be appropriate for this patient. This scan was negative. The patient has received 3 cycles of chemotherapy with Streptozotocin and 5-fluorouracil. He has had a good partial response to therapy as demonstrated on CT scan. The patient is currently clinically well, his symptoms have resolved and weight stabilised. Good biochemical response to chemotherapy is indicated by halved pancreatic peptide levels. To date chemotherapy has been the mainstay of therapy for neuroendocrine tumours. Radioimmunotherapy (targeted to SR positive tumours) is currently being investigated as a therapy alternative and may be a future treatment option. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. 21 CFR 872.1850 - Lead-lined position indicator.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1850 Lead-lined position indicator. (a... dental x-ray tube and intended to aid in positioning the tube, to prevent the misfocusing of the x-rays by absorbing divergent radiation, and to prevent leakage of radiation. (b) Classification. Class I...

  10. A digital position-indication system for control rods

    International Nuclear Information System (INIS)

    Nishizawa, Yukio; Hayakawa, Toshifumi

    1979-01-01

    Systems that detect and indicate the position of the control rods that regulate the thermal output of a nuclear reactor play a particularly important role in monitoring its operational status. Conventionally, control rod position indication in pressurized water reactors has been of the analog type, utilizing the principle of the differential transformer. The present digital system was developed with the objective of achieving greater stability, greater accuracy, and higher reliability. The article gives a general description of the system and describes its advantages. (author)

  11. Bench calibration of INDUS-2 beam position indicators

    International Nuclear Information System (INIS)

    Tyagi, Y.; Banerji, Anil; Kotaiah, S.

    2005-01-01

    A third generation synchrotron radiation source of energy 2.5 GeV named INDUS-2 at Centre for Advanced Technology (C.A.T), Indore (M.P) is in the advanced stage of construction. Accurate determination and correction of beam closed orbit in INDUS-2 machine within 100 of microns is a very desirable goal. Bench based calibration of Beam Position Indicators (BPI) play a very important and useful role during initial commissioning of electron machines. To precisely measure transverse position of electron beam in the Indus-2 storage ring, 56 Beam Position Indicators (BPI) will be installed in INDUS-2 machine. Out of 56 Beam Position Indicators 40 are of individual type whereas 16 are integrated with dipole vacuum chamber. The Beam Position Indicators are required to be calibrated before they can be installed. The calibration is done to determine electrical offset with respect to defined mechanical centre, to determine displacement sensitivities as well as non linearity's of BPI. Ideally when beam passes through the geometrical center of BPI's, all electrodes should have same signal strength. However due to different capacitance of electrodes and offset and drift in electronics, the electrical centre (mechanical x, y where all electrodes shows same signal strength) differs from mechanical centre of BPI. A fully automatic calibration system has been developed to carry out the calibration of Beam Position Indicators. A calibration software has been developed which has necessary utilities to process and display calibration data and results. This paper describes the calibration results of Indus-2 BPM. (author)

  12. Multiple-scanning-probe tunneling microscope with nanoscale positional recognition function.

    Science.gov (United States)

    Higuchi, Seiji; Kuramochi, Hiromi; Laurent, Olivier; Komatsubara, Takashi; Machida, Shinichi; Aono, Masakazu; Obori, Kenichi; Nakayama, Tomonobu

    2010-07-01

    Over the past decade, multiple-scanning-probe microscope systems with independently controlled probes have been developed for nanoscale electrical measurements. We developed a quadruple-scanning-probe tunneling microscope (QSPTM) that can determine and control the probe position through scanning-probe imaging. The difficulty of operating multiple probes with submicrometer precision drastically increases with the number of probes. To solve problems such as determining the relative positions of the probes and avoiding of contact between the probes, we adopted sample-scanning methods to obtain four images simultaneously and developed an original control system for QSPTM operation with a function of automatic positional recognition. These improvements make the QSPTM a more practical and useful instrument since four images can now be reliably produced, and consequently the positioning of the four probes becomes easier owing to the reduced chance of accidental contact between the probes.

  13. Monitoring positive mental health and its determinants in Canada: the development of the Positive Mental Health Surveillance Indicator Framework

    Directory of Open Access Journals (Sweden)

    H. Orpana

    2016-01-01

    Full Text Available Introduction: The Mental Health Strategy for Canada identified a need to enhance the collection of data on mental health in Canada. While surveillance systems on mental illness have been established, a data gap for monitoring positive mental health and its determinants was identified. The goal of this project was to develop a Positive Mental Health Surveillance Indicator Framework, to provide a picture of the state of positive mental health and its determinants in Canada. Data from this surveillance framework will be used to inform programs and policies to improve the mental health of Canadians. Methods: A literature review and environmental scan were conducted to provide the theoretical base for the framework, and to identify potential positive mental health outcomes and risk and protective factors. The Public Health Agency of Canada’s definition of positive mental health was adopted as the conceptual basis for the outcomes of this framework. After identifying a comprehensive list of risk and protective factors, mental health experts, other governmental partners and non-governmental stakeholders were consulted to prioritize these indicators. Subsequently, these groups were consulted to identify the most promising measurement approaches for each indicator. Results: A conceptual framework for surveillance of positive mental health and its determinants has been developed to contain 5 outcome indicators and 25 determinant indicators organized within 4 domains at the individual, family, community and societal level. This indicator framework addresses a data gap identified in Canada’s strategy for mental health and will be used to inform programs and policies to improve the mental health status of Canadians throughout the life course.

  14. Indications for direct multidirectional or multiplanar electronic reconstructions in CT-scanning of the head

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Veiga-Pires, J.A.; Gooskens, R.; Troost, J.

    1982-01-01

    The authors set out to indicate the optimal applications at minimum radiation penalty of both direct multidirectional and multiplanar electronic reconstruction modes in CT-scanning of the head by means of two illustrative case reports of midline congenital tumours. (orig.)

  15. Glue-sniffing as a cause of a positive radio-isotope brain scan

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, C M; Adams, F G

    1982-08-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas of increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing.

  16. Glue-sniffing as a cause of a positive radio-isotope brain scan

    International Nuclear Information System (INIS)

    Lamont, C.M.; Adams, F.G.

    1982-01-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas if increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing. (orig.)

  17. Excessive lateral patellar translation on axial computed tomography indicates positive patellar J sign.

    Science.gov (United States)

    Xue, Zhe; Song, Guan-Yang; Liu, Xin; Zhang, Hui; Wu, Guan; Qian, Yi; Feng, Hua

    2018-03-20

    The purpose of the study was to quantify the patellar J sign using traditional computed tomography (CT) scans. Fifty-three patients (fifty-three knees) who suffered from recurrent patellar instability were included and analyzed. The patellar J sign was evaluated pre-operatively during active knee flexion and extension. It was defined as positive when there was obvious lateral patellar translation, and negative when there was not. The CT scans were performed in all patients with full knee extension; and the parameters including bisect offset index (BOI), patellar-trochlear-groove (PTG) distance, and patellar lateral tilt angle (PLTA) were measured on the axial slices. All the three parameters were compared between the J sign-positive group (study group) and the J sign-negative group (control group). In addition, the optimal thresholds of the three CT scan parameters for predicting the positive patellar J sign were determined with receiver operating characteristic (ROC) curves, and the diagnostic values were assessed by the area under the curve (AUC). Among the fifty-three patients (fifty-three knees), thirty-seven (70%) showed obvious lateral patellar translation, which were defined as positive J sign (study group), and the remaining sixteen (30%) who showed no lateral translation were defined as negative J sign (control group). The mean values of the three CT parameters in the study group were all significantly larger compared to the control group, including BOI (121 ± 28% vs 88 ± 12%, P = 0.038), PTG distance (5.2 ± 6.6 mm vs - 4.4 ± 5.2 mm, P J sign was 97.5% (Sensitivity = 83.3%, Specificity = 87.5%). In this study, the prevalence of positive patellar J sign was 70%. The BOI measured from the axial CT scans of the knee joint can be used as an appropriate predictor to differentiate the positive J sign from the negative J sign, highlighting that the excessive lateral patellar translation on axial CT scan indicates positive

  18. [Social self-positioning as indicator of socioeconomic status].

    Science.gov (United States)

    Fernández, E; Alonso, R M; Quer, A; Borrell, C; Benach, J; Alonso, J; Gómez, G

    2000-01-01

    Self-perceived class results from directly questioning subjects about his or her social class. The aim of this investigation was to analyse self-perceived class in relation to other indicator variables of socioeconomic level. Data from the 1994 Catalan Health Interview Survey, a cross-sectional survey of a representative sample of the non-institutionalised population of Catalonia was used. We conducted a discriminant analysis to compute the degree of right classification when different socioeconomic variables potentially related to self-perceived class were considered. All subjects who directly answered the questionnaire were included (N = 12,245). With the aim of obtaining the discriminant functions in a group of subjects and to validate it in another one, the subjects were divided into two random samples, containing approximately 75% and 25% of subjects (analysis sample, n = 9,248; and validation sample, n = 2,997). The final function for men and women included level of education, social class (based in occupation) and equivalent income. This function correctly classified 40.9% of the subjects in the analysis sample and 39.2% in the validation sample. Two other functions were selected for men and women separately. In men, the function included level of education, professional category, and family income (39.2% of classification in analysis sample and 37.2% in validation sample). In women, the function (level of education, working status, and equivalent income) correctly classified 40.3% of women in analysis sample whereas the percentage was 38.9% in validation sample. The percentages of right classification were higher for the highest and lowest classes. These results show the utility of a simple variable to self-position within the social scale. Self-perceived class is related to education, income, and working determinants.

  19. Registration accuracy and image quality of time averaged mid-position CT scans for liver SBRT

    NARCIS (Netherlands)

    Kruis, Matthijs F.; van de Kamer, Jeroen B.; Sonke, Jan-Jakob; Jansen, Edwin P. M.; van Herk, Marcel

    2013-01-01

    The purpose was to validate the accuracy of motion models derived from deformable registration from four-dimensional computed tomography (4DCT) and breath-hold contrast enhanced computed tomography (BHCCT) scans for liver SBRT. Additionally, the image quality of the time averaged mid-position (MidP)

  20. Social position and health in old age: the relevance of different indicators of social position

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Holstein, Bjørn E; Osler, Merete

    2003-01-01

    for men and women. In men the odds ratios of housing tenure on four health variables were strong and unaffected by education and occupation while in women the odds ratios of income on three health variables were strong and unaffected by education and occupation. CONCLUSION: This study demonstrates strong......AIMS: An analysis was undertaken to investigate social inequalities in health among old men and women in relation to five indicators of social position. METHODS: The study is based on a population-based cross-sectional survey among 748 75-year-old men and women, which was performed as clinical......, consistent associations between variables of material wealth indicators and various measures of health among 75-year-old men and women....

  1. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  2. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  3. Towards automatic patient positioning and scan planning using continuously moving table MR imaging.

    Science.gov (United States)

    Koken, Peter; Dries, Sebastian P M; Keupp, Jochen; Bystrov, Daniel; Pekar, Vladimir; Börnert, Peter

    2009-10-01

    A concept is proposed to simplify patient positioning and scan planning to improve ease of use and workflow in MR. After patient preparation in front of the scanner the operator selects the anatomy of interest by a single push-button action. Subsequently, the patient table is moved automatically into the scanner, while real-time 3D isotropic low-resolution continuously moving table scout scanning is performed using patient-independent MR system settings. With a real-time organ identification process running in parallel and steering the scanner, the target anatomy can be positioned fully automatically in the scanner's sensitive volume. The desired diagnostic examination of the anatomy of interest can be planned and continued immediately using the geometric information derived from the acquired 3D data. The concept was implemented and successfully tested in vivo in 12 healthy volunteers, focusing on the liver as the target anatomy. The positioning accuracy achieved was on the order of several millimeters, which turned out to be sufficient for initial planning purposes. Furthermore, the impact of nonoptimal system settings on the positioning performance, the signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) was investigated. The present work proved the basic concept of the proposed approach as an element of future scan automation. (c) 2009 Wiley-Liss, Inc.

  4. Measurement of position and profile of undulator radiation in Indus-2 using scanning wire monitor

    International Nuclear Information System (INIS)

    Kant, Chander; Lal, Sohan; Raghuwanshi, V.K.; Prasad, Vijendra

    2015-01-01

    Two planar undulators (U1 and U2) for Atomic Molecular Spectroscopy (AMOS) beamline and Angle Resolved Photoelectron Spectroscopy (ARPES) beamline have been installed in Indus-2. The U1 undulator is designed to produce photons in the energy range of 6 eV to 250 eV and U2 undulator is designed to produce photons in the energy range of 30 eV to 600 eV. In order to measure the position and vertical profile of photon beams emitted from these undulators, one scanning wire monitor has been installed in each beamline front end. In these scanning wire monitors, a gold coated tungsten wire of 100 μm thickness, stretched between a fork shaped alumina ceramic holder, is scanned vertically perpendicular to the direction of propagation of photon beam by using a precisely controlled stepper motor. The photo-electron current generated in the wire is measured by an electrometer. A graphical user interface has been developed which facilitates the scanning as per the given range, plots the graphs and stores the scanned data in Excel file. This paper describes our experience and usefulness of these wire monitors during commissioning of planar undulators in Indus-2. (author)

  5. A two-dimensional position sensitive gas chamber with scanned charge transfer readout

    International Nuclear Information System (INIS)

    Gomez, F.; Iglesias, A.; Lobato, R.; Mosquera, J.; Pardo, J.; Pena, J.; Pazos, A.; Pombar, M.; Rodriguez, A.

    2003-01-01

    We have constructed and tested a two-dimensional position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position-dependent charge transfer technique. It has been implemented by using gate strips perpendicularly oriented to the collector strips. This solution reduces considerably the number of electronic readout channels needed to cover large detector areas. The use of a 25 μm thick kapton etched circuit allows high charge transfer efficiency with a low gating voltage, consequently needing a very simple commutating circuit. The present prototype covers 8x8 cm 2 with a pixel size of 1.27x1.27 mm 2 . Depending on the intended use and beam characteristics a smaller effective pixel is feasible and larger active areas are possible. This detector can be used for X-ray or other continuous beam intensity profile monitoring

  6. Position indicating split toroid for the RACE experiment

    International Nuclear Information System (INIS)

    Hurst, B.; Folkman, K.

    2007-01-01

    Aspects of the recent reactor accelerator coupled experiments (RACE) carried out at University of Texas Nuclear Engineering Teaching Laboratory will be discussed. In particular, a compact instrument that allowed a continuous non-invasive means of determining the relative electron beam position was developed. The operation of the instrument is similar to an inductive current pick up toroid except that the core is sectioned radially, which allows spatial information to be derived from the induced voltages. Results of initial tests, both in beam and with a pulser, will be presented along with plans to optimize future designs

  7. Isohaline position as a habitat indicator for estuarine populations

    Science.gov (United States)

    Jassby, Alan D.; Kimmerer, W.J.; Monismith, Stephen G.; Armor, C.; Cloern, James E.; Powell, T.M.; Vedlinski, Timothy J.

    1995-01-01

    Populations of native and introduced aquatic organisms in the San Francisco Bay/Sacramento-San Joaquin Delta Estuary ("Bay/Delta") have undergone significant declines over the past two decades. Decreasedriver inflow due to drought and increased freshwater diversion have contributed to the decline of atleast some populations. Effective management of the estuary's biological resources requires a sensitive indicatorof the response to freshwater inflow that has ecological significance, can be measured accurately and easily,and could be used as a "policy" variable to set standards for managing freshwater inflow. Positioning of the2% (grams of salt per kilogram of seawater) bottom salinity value along the axis of the estuary was examinedfor this purpose.

  8. Validation of a new noniterative method for accurate position determination of a scanning laser vibrometer

    Science.gov (United States)

    Pauwels, Steven; Boucart, Nick; Dierckx, Benoit; Van Vlierberghe, Pieter

    2000-05-01

    The use of a scanning laser Doppler vibrometer for vibration testing is becoming a popular instrument. The scanning laser Doppler vibrometer is a non-contacting transducer that can measure many points at a high spatial resolution in a short time. Manually aiming the laser beam at the points that need to be measured is very time consuming. In order to use it effectively, the position of the laser Doppler vibrometer needs to be determined relative to the structure. If the position of the laser Doppler vibrometer is known, any visible point on the structure can be hit and measured automatically. A new algorithm for this position determination is developed, based on a geometry model of the structure. After manually aiming the laser beam at 4 or more known points, the laser position and orientation relative to the structure is determined. Using this calculated position and orientation a list with the mirror angles for every measurement point is generated, which is used during the measurement. The algorithm is validated using 3 practical cases. In the first case a plate is used of which the points are measured very accurately, so the geometry model is assumed to be perfect. The second case is a brake disc. Here the geometry points are measured with a ruler, thus not so accurate. The final validation is done on a body in white of a car. A reduced finite element model is used as geometry model. This calibration shows that the new algorithm is very effective and practically usable.

  9. The percentage of migration as indicator of femoral head position

    International Nuclear Information System (INIS)

    Ekloef, O.; Ringertz, H.; Samuelsson, L.; Karolinska Sjukhuset, Stockholm; Karolinska Sjukhuset, Stockholm

    1988-01-01

    In childhood subluxation of one or both hips may develop rather insidiously. For lack of generally accepted objective methods of assessment, ambiguous interpretations of findings in serial examinations are common. Many subluxations are overlooked during the early stages. In order to overcome such disadvantages, determination of the percentage of migration seems to be a reasonably easy and reliable technique facilitating evaluation of impending dislocation. This investigation was carried out in order to estabilsh norms applicable to patients in the pediatric age interval. The 98th percentile of migration increases with age from 16% in patients < 4 years of age to 24% in patients ≥ 12 years. Higher figures represent subluxation. If the migration exceeds 80% a manifest luxation is present. A difference in migration between the two hips larger than 12% indicates abnormality calling for clinical and radiologic follow-up. (orig.)

  10. Characterization of Line Nanopatterns on Positive Photoresist Produced by Scanning Near-Field Optical Microscope

    Directory of Open Access Journals (Sweden)

    Sadegh Mehdi Aghaei

    2015-01-01

    Full Text Available Line nanopatterns are produced on the positive photoresist by scanning near-field optical microscope (SNOM. A laser diode with a wavelength of 450 nm and a power of 250 mW as the light source and an aluminum coated nanoprobe with a 70 nm aperture at the tip apex have been employed. A neutral density filter has been used to control the exposure power of the photoresist. It is found that the changes induced by light in the photoresist can be detected by in situ shear force microscopy (ShFM, before the development of the photoresist. Scanning electron microscope (SEM images of the developed photoresist have been used to optimize the scanning speed and the power required for exposure, in order to minimize the final line width. It is shown that nanometric lines with a minimum width of 33 nm can be achieved with a scanning speed of 75 µm/s and a laser power of 113 mW. It is also revealed that the overexposure of the photoresist by continuous wave laser generated heat can be prevented by means of proper photoresist selection. In addition, the effects of multiple exposures of nanopatterns on their width and depth are investigated.

  11. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  12. Social position and health in old age. The relevance of different indicators of social position

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Holstein, Bjørn Evald; Osler, Merete

    2002-01-01

    Social medicine, social position, chronic diseases, material wealth, income, tenure, oral health, functional ability, well-being, mobility......Social medicine, social position, chronic diseases, material wealth, income, tenure, oral health, functional ability, well-being, mobility...

  13. Influence of antibacterial therapy on bone scan indices at foot inflammation in diabetes mellitus accompanied by diabetic foot syndrome

    International Nuclear Information System (INIS)

    Slavnov, V.M.; Bolgars'ka, S.V.; Taran, E.V.; Markov, V.V.

    2004-01-01

    The influence of antibacterial therapy on bone scan indices at foot inflammation in patients with diabetes mellitus (DM) accompanied by diabetic foot syndrome was studied. Bone scan was performed using scintillation tomographic gamma-camera hours after intravenous injection of 99m Tc-methylene diphosphonate

  14. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    International Nuclear Information System (INIS)

    Hinzpeter, Ricarda; Sprengel, Kai; Wanner, Guido A.; Mildenberger, Peter; Alkadhi, Hatem

    2017-01-01

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  15. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    Energy Technology Data Exchange (ETDEWEB)

    Hinzpeter, Ricarda, E-mail: Ricarda.Hinzpeter@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland); Sprengel, Kai, E-mail: Kai.Sprengel@usz.ch [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Wanner, Guido A., E-mail: Guido.Wanner@sbk-vs.de [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Department of General Surgery, Schwarzwald-Baar Klinikum, University of Freiburg, Klinikstr. 11, D-78052 Villingen-Schwenningen (Germany); Mildenberger, Peter, E-mail: peter.mildenberger@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, University Hospital of Mainz, Langenbeckstr. 1, D-55131 Mainz (Germany); Alkadhi, Hatem, E-mail: hatem.alkadhi@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland)

    2017-03-15

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  16. Survey regarding the clinical practice of cardiac CT in Germany. Indications, scanning technique and reporting

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Marc H.; Hamm, B.; Dewey, M. [Inst. fuer Radiologie, Charite - Universitaetsmedizin Berlin (Germany)

    2009-12-15

    Purpose: to obtain an overview of the current clinical practice of cardiac computed tomography (CT) in Germany. Materials and methods: a 30-item question-naire was mailed to 149 providers of cardiac CT in Germany. The items asked about indications, scanning technique and reporting, data storage, and cost of the examination. Results: overall 45 questionnaires could be analyzed (30%). The majority of centers (76%, 34 of 45 centers) used CT scanners of the latest generation (at least 64 rows). The most common appropriate indications were exclusion of coronary artery disease (91%, 41/45), coronary anomalies (80%, 36/45), and follow-up after coronary artery bypass grafting (53%, 24/45). Each center examined on average 243 {+-} 310 patients in 2007 and the number of centers performing cardiac CT increased significantly in 2007 (p = 0.035) compared with the preceding year. Most used sublingual nitroglycerin (84%, 38/45; median of 2 sprays = 0.8 mg) and/or a beta blocker (86%, 39/44; median of 5 mg IV, median heart rate threshold: 70 beats/min). Many providers used ECG-triggered tube current modulation (65%, 29/44) and/or adjusted the tube current to the body mass index or body weight (63%, 28/44). A median slice thickness of 0.75 mm with a 0.5 mm increment and a 20 cm field-of-view was most commonly used. Source images in orthogonal planes (96%, 43/45), curved MPRs (93%, 42/45), and thin-slice MIPs (69%, 31/45) were used most frequently for interpretation. Extracardiac structures were also evaluated by 84% of the centers (38/45). The mean examination time was 16.2 min and reporting took an average of 28.8 min. (orig.)

  17. Adrenal scan in 17-alpha-hydroxylase deficiency: false indication of adrenal adenoma

    International Nuclear Information System (INIS)

    Shore, R.M.; Lieberman, L.M.; Newman, T.J.; Friedman, A.; Bargman, G.J.

    1981-01-01

    A patient who was thought to have testicular feminization syndrome and primary aldosteronism had an adrenal scan that suggested an adrenal adenoma. After later diagnosis of 17-alpha-hydroxylase deficiency, she was treated with glucocorticoids rather than surgery. Her clinical course and a repeat adrenal scan confirmed she did not have a tumor

  18. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  19. Side-Scan Sonar Image Mosaic Using Couple Feature Points with Constraint of Track Line Positions

    Directory of Open Access Journals (Sweden)

    Jianhu Zhao

    2018-06-01

    Full Text Available To obtain large-scale seabed surface image, this paper proposes a side-scan sonar (SSS image mosaic method using couple feature points (CFPs with constraint of track line positions. The SSS geocoded images are firstly used to form a coarsely mosaicked one and the overlapping areas between adjacent strip images can be determined based on geographic information. Inside the overlapping areas, the feature point (FP detection and registration operation are adopted for both strips. According to the detected CFPs and track line positions, an adjustment model is established to accommodate complex local distortions as well as ensure the global stability. This proposed method effectively solves the problem of target ghosting or dislocation and no accumulated errors arise in the mosaicking process. Experimental results show that the finally mosaicked image correctly reflects the object distribution, which is meaningful for understanding and interpreting seabed topography.

  20. A two-dimensional position sensitive gas chamber with scanned charge transfer readout

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F. E-mail: faustgr@usc.es; Iglesias, A.; Lobato, R.; Mosquera, J.; Pardo, J.; Pena, J.; Pazos, A.; Pombar, M.; Rodriguez, A

    2003-10-21

    We have constructed and tested a two-dimensional position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position-dependent charge transfer technique. It has been implemented by using gate strips perpendicularly oriented to the collector strips. This solution reduces considerably the number of electronic readout channels needed to cover large detector areas. The use of a 25 {mu}m thick kapton etched circuit allows high charge transfer efficiency with a low gating voltage, consequently needing a very simple commutating circuit. The present prototype covers 8x8 cm{sup 2} with a pixel size of 1.27x1.27 mm{sup 2}. Depending on the intended use and beam characteristics a smaller effective pixel is feasible and larger active areas are possible. This detector can be used for X-ray or other continuous beam intensity profile monitoring.

  1. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  2. The uterine blush. A potential false-positive in Meckel's scan interpretation

    International Nuclear Information System (INIS)

    Fink-Bennett, D.

    1982-01-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations

  3. The uterine blush. A potential false-positive in Meckel's scan interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fink-Bennett, D.

    1982-10-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.

  4. Compact very low temperature scanning tunneling microscope with mechanically driven horizontal linear positioning stage.

    Science.gov (United States)

    Suderow, H; Guillamon, I; Vieira, S

    2011-03-01

    We describe a scanning tunneling microscope for operation in a dilution refrigerator with a sample stage which can be moved macroscopically in a range up to a cm and with an accuracy down to the tens of nm. The position of the tip over the sample as set at room temperature does not change more than a few micrometers when cooling down. This feature is particularly interesting for work on micrometer sized samples. Nanostructures can be also localized and studied, provided they are repeated over micrometer sized areas. The same stage can be used to approach a hard single crystalline sample to a knife and cleave it, or break it, in situ. In situ positioning is demonstrated with measurements at 0.1 K in nanofabricated samples. Atomic resolution down to 0.1 K and in magnetic fields of 8 T is demonstrated in NbSe(2). No heat dissipation nor an increase in mechanical noise has been observed at 0.1 K when operating the slider.

  5. Development of control rod position indicator using seismic-resistance reed switches for integral reactor

    International Nuclear Information System (INIS)

    Yu, Je Yong; Kim, Ji Ho; Huh, Hyung; Choi, Myoung Hwan; Sohn, Dong Seong

    2008-01-01

    The Reed Switch Position Transmitter (RSPT) is used as a position indicator for the control rod in commercial nuclear power plants made by ABB-CE. But this position indicator has some problems when directly adopting it to the integral reactor. The Control Element Drive Mechanism (CEDM) for the integral reactor is designed to raise and lower the control rod in steps of 2mm in order to satisfy the design features of the integral reactor which are the soluble boron free operation and the use of a nuclear heating for the reactor start-up. Therefore the resolution of the position indicator for the integral reactor should be achieved to sense the position of the control rod more precisely than that of the RSPT of the ABB-CE. This paper adopts seismic resistance reed switches to the position indicator in order to reduce the damages or impacts during the handling of the position indicator and earthquake

  6. Preliminary performance test of control rod position indicator for ballscrew type CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. H.; Hu, H.; Lee, J. S.; Kim, J. I.

    2003-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The prototype of control rod position indicator having the high performance for the ballscrew type CEDM was developed on the basis of RSPT technology identified through the survey. The characteristics of control rod position indicator was defined and documented through design procedure and preliminary performance test

  7. Effect of scanning in the supine and prone positions on dilation of air-charged colon in CTVC

    International Nuclear Information System (INIS)

    Ye Jing; Chen Junkun; Zhang Zongjun; Wang Junpeng; Gao Dazhi

    2003-01-01

    Objective: To evaluate the effect of scanning in the supine and prone positions on dilation of air-charged colon in CT virtual colonoscopy (CTVC). Methods: Thirty cases underwent CTVC scanning in both the supine and prone positions immediately before colonoscopy, and the dilation of each intestine was graded. The differences of colon dilation in different positions were compared. Results: In supine and prone position, there were 26 (17.3%) and 22 (14.7%) insufficient dilating colon segments, respectively, and only 5 (3.3%) insufficient dilating colon segments in double positions. 15(50.0%) and 13(43.3%) colons dilated insufficiently in supine and prone position, respectively, and decreased to 5 (16.7%) in double positions. The dilation of rectum, sigmoid colon, and transverse colon had significant difference in different positions. Conclusion: When performing CTVC, it is highly necessary to scan in both the supine and prone positions in order to ensure the sufficient dilation of colon. In supine position, the dilation of transverse colon is better, while the dilation of rectum and sigmoid colon in prone position is superior to that in supine position

  8. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    Science.gov (United States)

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. 46 CFR 169.555 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.555 Section 169.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... Emergency position indicating radio beacon (EPIRB). (a) Each vessel certificated for exposed waters must...

  10. 46 CFR 169.744 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.744 Section 169.744 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... position indicating radio beacon (EPIRB). Each EPIRB must be marked with the vessel's name. ...

  11. Influence of PET/CT-introduction on PET scanning frequency and indications. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Eschmann, S.M.; Krause, B.J.; Roedel, R.; Tiling, R.; Weckesser, M.

    2007-01-01

    Aim: to evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: the study included all examinations performed on stand alone PET- or PET/CT-scanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: the overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: the introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry. (orig.)

  12. New approach for control rod position indication system for light water power reactor

    International Nuclear Information System (INIS)

    Bahuguna, Sushil; Dhage, Sangeeta; Nawaj, S.; Salek, C.; Lahiri, S.K.; Marathe, P.P.; Mukhopadhyay, S.; Taly, Y.K.

    2015-01-01

    Control rod position indication system is an important system in a nuclear power plant to monitor and display control rod position in all regimes of reactor operation. A new approach to design a control rod position indication system for sensing absolute position of control rod in Light Water Power Reactor has been undertaken. The proposed system employs an inductive type, hybrid measurement strategy providing both analog position as well as digital zone indication with built-in temperature compensation. The new design approach meets single failure criterion through redundancy in design without sacrificing measurement resolution. It also provides diversity in measurement technique by indirect position sensing based on analysis of drive coil current signature. Prototype development and qualification at room temperature of the control rod position indication system (CRPIS) has been demonstrated. The article presents the design philosophy of control rod position indication system, the new measurement strategy for sensing absolute position of control rod, position estimation algorithm for both direct and indirect sensing and a brief account associated processing electronics. (author)

  13. Cardiac events in patients with positive exercise ECG and normal myocardial perfusion scan - a retrospective study

    International Nuclear Information System (INIS)

    Marshman, K.; Thomson, L.E.J.; Rowe, C.C.; Burns, A.J.; Woon, F.S.

    2002-01-01

    Full text: The low risk of future cardiac events following a normal myocardial perfusion study with normal stress ECG has been well documented. However, there is little literature regarding the prognosis in patients with a positive stress ECG (PosETT) and normal myocardial perfusion scan (MPS). A search of our database over an eighteen month period identified 21 patients who fitted study criteria. A PosETT was defined as stress induced horizontal or downsloping ST depression > 1mm in one or more leads with a normal baseline 12 lead ECG. Patients were divided into two subgroups depending on the severity of ST depression. A mildly PosETT was defined as ST depression of 1-1.5mm (n=10) and strongly PosETT was defined as ST depression of >2mm in at least one lead with depression in other leads (n=l 1). A normal MPS was defined as absence of reversible perfusion defects on SPECT imaging. Technetium 99m Tetrofosmin was the imaging agent used in 18/21 patients. All 21 patients exercised using the Bruce protocol for 3-12 minutes, and 9 experienced chest pain 12 months after the MPS, referring physicians were contacted. Cardiac events were defined as cardiac death, myocardial infarction, unstable angina, cardiac failure, revascularisation or a coronary angiogram demonstrating >70% stenosis. To date, follow up is complete in 11 patients with one confirmed case of single vessel revascularisation 3 months post MPS. Full follow up data will be presented. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  14. Heart position variability during voluntary moderate deep inspiration breath-hold radiotherapy for breast cancer determined by repeat CBCT scans.

    Science.gov (United States)

    van Haaren, Paul; Claassen-Janssen, Fiere; van de Sande, Ingrid; Boersma, Liesbeth; van der Sangen, Maurice; Hurkmans, Coen

    2017-08-01

    Voluntary moderate deep inspiration breath hold (vmDIBH) in left-sided breast cancer radiotherapy reduces cardiac dose. The aim of this study was to investigate heart position variability in vmDIBH using CBCT and to compare this variability with differences in heart position between vmDIBH and free breathing (FB). For 50 patients initial heart position with respect to the field edge (HP-FE) was measured on a vmDIBH planning CT scan. Breath-hold was monitored using an in-house developed vertical plastic stick. On pre-treatment CBCT scans, heart position variability with respect to the field edge (Δ HP-FE ) was measured, reflecting heart position variability when using an offline correction protocol. After registering the CBCT scan to the planning CT, heart position variability with respect to the chest wall (Δ HP-CW ) was measured, reflecting heart position variability when using an online correction protocol. As a control group, vmDIBH and FB computed tomography (CT) scans were acquired for 30 patients and registering both scans on the chest wall. For 34 out of 50 patients, the average HP-FE and HP-CW increased over the treatment course in comparison to the planning CT. Averaged over all patients and all treatment fractions, the Δ HP-FE and the Δ HP-CW was 0.8±4.2mm (range -9.4-+10.6mm) and 1.0±4.4mm (range -8.3-+10.4mm) respectively. The average gain in heart to chest wall distance was 11.8±4.6mm when using vmDIBH instead of FB. In conclusion, substantial variability in heart position using vmDIBH was observed during the treatment course. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Indicators chest rheography at swimmers at rest and after exercise in different body positions

    Directory of Open Access Journals (Sweden)

    Mariya Sinyugina

    2014-12-01

    Full Text Available Purpose: Study of chest rheography for skilled swimmers when the dosage of physical activity in different body positions. Materials and Methods: the study involved 20 qualified swimmers for middle and long distance. Results: studies changes rheographic indicators from qualified swimmers in response to exercise in different positions of the body showed a clear dependence of the structure and functional hemodynamic changes the position of the body in which the exercise is carried out. Conclusions: found that when evaluating the success of readiness of swimmers and planning training loads must be based on indicators of physical performance obtained during exercise in a horizontal position of the body.

  16. Positive indium-III bone marrow scan in metastatic breast carcinoma. Case report

    International Nuclear Information System (INIS)

    LaManna, M.M.; Hyzinski, M.; Swami, V.K.; Parker, J.A.

    1984-01-01

    Indium is generally presumed to localize in the bone marrow within the erythroid cell line. Fibrosis, inflammation, lymphoma, extended field radiation, chemotherapy, or combinations of both treatment modalities generally depress the uptake of indium by the marrow in a complex fashion. We report a case of metastatic breast carcinoma and pancytopenia in which the In-111 scan appeared qualitatively similar to a Tc-99m MDP bone scan. Findings were confirmed by bone marrow biopsy

  17. Arrangement of permanent magnet and reed switches for control rod position indicator of SMART CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. I.; Kim, J. H.; Hur, H.; Jang, M. H.

    2001-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indication. In this study, the characteristics of permanent magnet and reed switches are introduced and the calculation method for arrangement of permanent magnet and reed switch is presented

  18. Design of magnetic flux concentrator of permancent magnet for control rod position indicator of SMART CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. H.; Hur, H.; Kim, J. I.

    2002-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The arrangement of permanent magnet and reed switches is the most important procedure in the design of control rod position indication. In this study, the magnetic flux concentrator of permanent magnet is introduced and the calculation method for effective flux area for reed switch is presented

  19. Tri-code inductance control rod position indicator with several multi-coding-bars

    International Nuclear Information System (INIS)

    Shi Jibin; Jiang Yueyuan; Wang Wenran

    2004-01-01

    A control rod position indicator named as tri-code inductance control rod position indicator with multi-coding-bars, which possesses simple structure, reliable operation and high precision, is developed. The detector of the indicator is composed of K coils, a compensatory coil and K coding bars. Each coding bar consists of several sections of strong magnetic cores, several sections of weak magnetic cores and several sections of non-magnetic portions. As the control rod is withdrawn, the coding bars move in the center of the coils respectively, while the constant alternating current passes the coils and makes them to create inductance alternating voltage signals. The outputs of the coils are picked and processed, and the tri-codes indicating rod position can be gotten. Moreover, the coding principle of the detector and its related structure are introduced. The analysis shows that the indicator owns more advantage over the coils-coding rod position indicator, so it can meet the demands of the rod position indicating in nuclear heating reactor (NHR). (authors)

  20. Two unusual causes of peripatellar nonmetastatic positive bone scans in patients with malignancies: case reports

    International Nuclear Information System (INIS)

    Turner, J.W.; Syed, I.B.; Spencer, R.P.

    1976-01-01

    Bone scans performed with /sup 99m/Tc-polyphosphate in two patients with epidermoid carcinoma of the lung each showed activity in one knee area. In the first case, radiographs of the area revealed Pellegrini-Stieda calcification over the internal femoral condyle. Uptake corresponded to this process, rather than to a lesion deep in the bone. In the second case, the activity accumulation in the right tibia was the only abnormality noted in the scan. An open biopsy revealed Paget's disease, and no radiographic evidence of Paget's disease was found in any other bone. These cases again illustrate that localized accumulation of a bone-scanning agent, in patients with known primary tumors, does not necessarily denote malignancy in bone

  1. False Positive Uptake in Bilateral Gynecomastia on 68Ga-PSMA PET/CT Scan.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Nair, Bindu P; Pillai, M R A; Madhavan, Jayaprakash

    2017-09-01

    A 66-year-old man on hormonal therapy with prostate cancer was referred for Ga-PSMA PET/CT scan for biochemical recurrence. Ga-PSMA PET/CT scan detected moderate heterogeneous tracer concentration in bilateral breast parenchyma, in addition to the abnormal tracer concentration in enlarged prostate gland, right external iliac lymph node, and sclerotic lesion in L4 vertebra. On clinical examination, he was found to have bilateral gynecomastia. Abnormal concentration of Ga-PSMA in breast cancer is now well known, and in this context, it is important to know that tracer localization can occur in gynecomastia as well, as evidenced in this case.

  2. Aperture Determination in the LHC Based on an Emittance Blowup Technique with Collimator Position Scan

    CERN Document Server

    Assmann, R W; del Carmen Alabau, M; Giovannozzi, M; Muller, GJ; Redaelli, S; Schmidt, F; Tomas, R; Wenninger, J; Wollmann, D

    2011-01-01

    A new method to determine the LHC aperture was proposed. The new component is a collimator scan technique that refers the globally measured aperture limit to the shadow of the primary collimator, expressed in sigmas of rms beam size. As a by-product the BLM response to beam loss is quantified. The method is described and LHC measurement results are presented.

  3. False-positive I-131 scan by contaminated muffler in a patient with thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Han Kyung; Kim, Min Woo; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Hospital, Chonju (Korea, Republic of)

    2006-02-15

    A 39-year-old female patient who had undergone a total thyroidectomy for a papillary thyroid carcinoma underwent a whole body scan with I-131. The I-131 scan was performed 72 hours after administering 185 MBq (5 mGi) of an I-131 solution. The anterior image of head, neck, and upper chest showed multiple areas of increased uptake in the mediastinal area considering of functional metastasis. However, radioactivity was not evident in the image taken after removing her clothes and muffler. The image obtained after placing the muffler on the pallet showed that the radioactivity was still present. It is well known that artifacts on an I-131 scan can be produced by styling hair sputum, drooling during sleep, chewing gum, and paper or a cloth handkerchief that is contaminated with the radioactive iodine from either perspiration or saliva. This activity might be mistaken for a functional metastasis. Therefore, it is essential that an image be obtained after removing the patient's clothes. In this study, artifacts due to a contaminated muffler on the I-131 scan were found. These mimicked a functional metastasis of the mediastinal area in a patient with a papillary thyroid carcinoma.

  4. A robust method for processing scanning probe microscopy images and determining nanoobject position and dimensions

    NARCIS (Netherlands)

    Silly, F.

    2009-01-01

    P>Processing of scanning probe microscopy (SPM) images is essential to explore nanoscale phenomena. Image processing and pattern recognition techniques are developed to improve the accuracy and consistency of nanoobject and surface characterization. We present a robust and versatile method to

  5. Fluorodeoxyglucose-positron emission tomography scan-positive recurrent papillary thyroid cancer and the prognosis and implications for surgical management

    Directory of Open Access Journals (Sweden)

    Schreinemakers Jennifer MJ

    2012-09-01

    Full Text Available Abstract Background To compare outcomes for patients with recurrent or persistent papillary thyroid cancer (PTC who had metastatic tumors that were fluorodeoxyglucose-positron emission tomography (FDG-PET positive or negative, and to determine whether the FDG-PET scan findings changed the outcome of medical and surgical management. Methods From a prospective thyroid cancer database, we retrospectively identified patients with recurrent or persistent PTC and reviewed data on demographics, initial stage, location and extent of persistent or recurrent disease, clinical management, disease-free survival and outcome. We further identified subsets of patients who had an FDG-PET scan or an FDG-PET/CT scan and whole-body radioactive iodine scans and categorized them by whether they had one or more FDG-PET-avid (PET-positive lesions or PET-negative lesions. The medical and surgical treatments and outcome of these patients were compared. Results Between 1984 and 2008, 41 of 141 patients who had recurrent or persistent PTC underwent FDG-PET (n = 11 or FDG-PET/CT scans (n = 30; 22 patients (54% had one or more PET-positive lesion(s, 17 (41% had PET-negative lesions, and two had indeterminate lesions. Most PET-positive lesions were located in the neck (55%. Patients who had a PET-positive lesion had a significantly higher TNM stage (P = 0.01, higher age (P = 0.03, and higher thyroglobulin (P = 0.024. Only patients who had PET-positive lesions died (5/22 vs. 0/17 for PET-negative lesions; P = 0.04. In two of the seven patients who underwent surgical resection of their PET-positive lesions, loco-regional control was obtained without evidence of residual disease. Conclusion Patients with recurrent or persistent PTC and FDG-PET-positive lesions have a worse prognosis. In some patients loco-regional control can be obtained without evidence of residual disease by reoperation if the lesion is localized in the neck or mediastinum.

  6. National quality indicators and policies from 15 countries leading in adult end-of-life care: a systematic environmental scan.

    Science.gov (United States)

    Virdun, Claudia; Luckett, Tim; Lorenz, Karl A; Phillips, Jane

    2018-06-01

    The importance of measuring the quality of end-of-life care provision is undisputed, but determining how best to achieve this is yet to be confirmed. This study sought to identify and describe national end-of-life care quality indicators and supporting policies used by countries leading in their end-of-life care provision. A systematic environmental scan that included a web search to identify relevant national policies and indicators; hand searching for additional materials; information from experts listed for the top 10 (n=15) countries ranked in the 'quality of care' category of the 2015 Quality of Death Index study; and snowballing from Index experts. Ten countries (66%) have national policy support for end-of-life care measurement, five have national indicator sets, with two indicator sets suitable for all service providers. No countries mandate indicator use, and there is limited evidence of consumer engagement in development of indicators. Two thirds of the 128 identified indicators are outcomes measures (62%), and 38% are process measures. Most indicators pertain to symptom management (38%), social care (32%) or care delivery (27%). Measurement of end-of-life care quality varies globally and rarely covers all care domains or service providers. There is a need to reduce duplication of indicator development, involve consumers, consider all care providers and ensure measurable and relevant indicators to improve end-of-life care experiences for patients and families. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Performance estimation of control rod position indicator due to aging of magnet

    International Nuclear Information System (INIS)

    Yu, Je Yong; Kim, Ji Ho; Huh, Hyung; Choi, Myoung Hwan; Sohn, Dong Seong

    2009-01-01

    The Control Element Drive Mechanism (CEDM) for the integral reactor is designed to raise and lower the control rod in steps of 2mm in order to satisfy the design features of the integral reactor which are the soluble boron free operation and the use of a nuclear heating for the reactor start-up. The actual position of the control rod could be achieved to sense the magnet connected to the control rod by the position indicator around the upper pressure housing of CEDM. It is sufficient that the actual position information of control rod at 20mm interval from the position indicator is used for the core safety analysis. As the magnet moves upward along the position indicator assembly from the bottom to the top in the upper pressure housing, the output voltage increases linearly step-wise at 0.2VDC increments. Between every step there are transient areas which occur by a contact closing of three reed switches which is the 2-3-2 contact closing sequence. In this paper the output voltage signal corresponding to the position of control rod was estimated on the 2-1-2 contact closing sequence due to the aging of the magnet.

  8. Position indicating systems and reed contact unit assemblies for such systems

    International Nuclear Information System (INIS)

    Foxworthy, M.K.

    1980-01-01

    Specifications are given for a position indicating system for determining the position of a movable member inside a sealed container such as the position of a control rod in a nuclear reactor. The system comprises a magnetic flux producing member mounted to the movable member so as to move with it, a series of magnetic reed contact units mounted along the outside of the sealed container to be individually actuated by the flux producer as the movable member moves within the sealed container to indicate the position of this member. Each of the reed contact units is connected to a source of alternating electric current to produce a magnetic flux field to minimize the flux differential between the actuated and unactuated reed contact positions. A second aspect of the invention provides for a low operating flux differential reed contact unit assembly for a position indicating system such that it is actuated by the magnetic member at one magnetic flux level and deactivated at a second level. There is a source of alternating current connected to a coil surrounding the reed contact unit so as to produce an alternating magnetic flux with amplitude less than the difference between the two levels. Variations are given, also diagrams and benefits. (U.K.)

  9. Fault tolerant, multiplexed control rod position detection and indication system for nuclear power plants

    International Nuclear Information System (INIS)

    Dufek, W.L.; Jelovich, J.J.; Neuner, J.A.

    1977-01-01

    The majority of Westinghouse nuclear plants placed in service thus far have incorporated a Rod Position Indication system based upon an analog design philosophy. This system, while meeting all functional and accuracy requirements, has proven somewhat cumbersome, particularly in the area of initial field calibration and maintenance. This paper describes a new Digital Rod Position Indication system (DRPI) developed for use with pressurized water reactors. The system is based upon a digital design philosophy and meets all previous design constraints and environmental requirements. Further, fault tolerance, improved accuracy, interference from adjacent rods and the elimination of adjustments and calibration has been provided

  10. A scan for positively selected genes in the genomes of humans and chimpanzees.

    Directory of Open Access Journals (Sweden)

    Rasmus Nielsen

    2005-06-01

    Full Text Available Since the divergence of humans and chimpanzees about 5 million years ago, these species have undergone a remarkable evolution with drastic divergence in anatomy and cognitive abilities. At the molecular level, despite the small overall magnitude of DNA sequence divergence, we might expect such evolutionary changes to leave a noticeable signature throughout the genome. We here compare 13,731 annotated genes from humans to their chimpanzee orthologs to identify genes that show evidence of positive selection. Many of the genes that present a signature of positive selection tend to be involved in sensory perception or immune defenses. However, the group of genes that show the strongest evidence for positive selection also includes a surprising number of genes involved in tumor suppression and apoptosis, and of genes involved in spermatogenesis. We hypothesize that positive selection in some of these genes may be driven by genomic conflict due to apoptosis during spermatogenesis. Genes with maximal expression in the brain show little or no evidence for positive selection, while genes with maximal expression in the testis tend to be enriched with positively selected genes. Genes on the X chromosome also tend to show an elevated tendency for positive selection. We also present polymorphism data from 20 Caucasian Americans and 19 African Americans for the 50 annotated genes showing the strongest evidence for positive selection. The polymorphism analysis further supports the presence of positive selection in these genes by showing an excess of high-frequency derived nonsynonymous mutations.

  11. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  12. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  13. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  14. Iterative learning control with basis functions for media positioning in scanning inkjet printers

    NARCIS (Netherlands)

    Bolder, J.J.; Lemmen, B.P.; Koekebakker, S.H.; Oomen, T.A.E.; Bosgra, O.H.; Steinbuch, M.

    2012-01-01

    In printing systems, the positioning accuracy of the medium with respect to the print heads directly impacts print quality. In a regular document inkjet printer, the main task of the media positioning drive is to shift the medium after the printhead has finished a pass. Most media have the tendency

  15. Evaluation of positional plagiocephaly: Conventional anthropometric measurement versus laser scanning method.

    Science.gov (United States)

    Nahles, Susanne; Klein, Martin; Yacoub, Anke; Neyer, Julia

    2018-01-01

    The incidence of plagiocephaly has increased in the 25 years since the "Back to Sleep" campaign in 1991 to prevent sudden infant death. Plagiocephaly is not considered to be a pathological condition. It is more of an esthetic impairment and could have potentially negative psychological or psychosocial consequences; therefore, treatment is recommended. The aim of this study is to compare conventional anthropometry and laser scanning - two different measurement methods - as diagnostic instruments for plagiocephaly. The present study also tests the measurement time of both methods and whether one method is easier on the patient than the other. A total of 44 children (21 girls, 23 boys) with a mean age of 8.8 months were involved in the present study. Of all patients, the following parameters were routinely evaluated using a standard protocol with the conventional anthropometric method and the scan method: head circumference, head length, head width, head diagonals, and distances ex-t. Furthermore, the time required to obtain measurements and the behavior of the children during measurement were documented. For statistical analysis, a t-test and a Wilcoxon test were used to analyze differences between the two methods. The results for head circumference showed a mean of 441.5 mm for the anthropometric measurements and 441.6 mm for the scan method, with no significant difference between the two methods. A significant difference was found regarding the head width, head length, diagonals, and distance ex-t. The measurement process using the scan method needed a mean of 579.6 s in contrast to the manual anthropometric method, which required a mean time of 180.5 s. In comparison with the conventional anthropometric method, measurements made with a 3D laser scanner yield inconsistent results. Moreover, the current state of technology of 3D cephalometry has no advantages compared with the conventional anthropometric method. Disadvantages worth mentioning appear to be the

  16. Mycobacterial Infection of the Gallbladder Masquerading as Gallbladder Cancer with a False Positive Pet Scan

    Directory of Open Access Journals (Sweden)

    Adeeb Majid

    2013-01-01

    Full Text Available Isolated mycobacterial infection of gall bladder is an extremely rare entity. Only anecdotal reports are evident in the literature. A preoperative diagnosis of mycobacterial infection of gallbladder is therefore very difficult. The case of a 72-year-old male who underwent surgery for suspected gallbladder cancer is presented. The diagnosis of cancer was based on radiological findings and an abnormal uptake of fluorine-18-fluoro-2-deoxy-D-glucose (FDG on positron emission tomography (PET scan whilst being followed up for colorectal cancer. He underwent cholecystectomy and gallbladder bed resection. Histopathology was consistent with mycobacterial infection of the gallbladder.

  17. Positive gallium scan in the syndrome of opsoclonus-myoclonus treated with adrenocorticotropic hormone

    International Nuclear Information System (INIS)

    Gumbinas, M.; Gratz, E.S.; Johnston, G.S.; Schwartz, A.D.

    1984-01-01

    The syndrome of opsoclonus and myoclonus may be the first presenting symptom of neuroblastoma. The disorder is often controlled by treatment with adrenocorticotropic hormone (ACTH). A child with this disorder and treated with ACTH gel had abnormal uptake of 67 Ga in both adrenal glands during studies to attempt to detect an occult neuroblastoma. Repeat 67 Ga scans proved to be normal once the ACTH was discontinued and the patient was treated with prednisone. It is concluded that ACTH stimulation of normal adrenal tissue was responsible for these abnormal findings

  18. PWMScan: a fast tool for scanning entire genomes with a position-specific weight matrix.

    Science.gov (United States)

    Ambrosini, Giovanna; Groux, Romain; Bucher, Philipp

    2018-03-05

    Transcription factors (TFs) regulate gene expression by binding to specific short DNA sequences of 5 to 20-bp to regulate the rate of transcription of genetic information from DNA to messenger RNA. We present PWMScan, a fast web-based tool to scan server-resident genomes for matches to a user-supplied PWM or TF binding site model from a public database. The web server and source code are available at http://ccg.vital-it.ch/pwmscan and https://sourceforge.net/projects/pwmscan, respectively. giovanna.ambrosini@epfl.ch. SUPPLEMENTARY DATA ARE AVAILABLE AT BIOINFORMATICS ONLINE.

  19. Prostate-Specific Antigen and Prostate-Specific Antigen Velocity as Threshold Indicators in 11C-Acetate PET/CTAC Scanning for Prostate Cancer Recurrence

    Science.gov (United States)

    Dusing, Reginald W.; Peng, Warner; Lai, Sue-Min; Grado, Gordon L.; Holzbeierlein, Jeffrey M.; Thrasher, J. Brantley; Hill, Jacqueline; Van Veldhuizen, Peter J.

    2014-01-01

    Purpose The aim of this study was to identify which patient characteristics are associated with the highest likelihood of positive findings on 11C-acetate PET/computed tomography attenuation correction (CTAC) (PET/CTAC) scan when imaging for recurrent prostate cancer. Methods From 2007 to 2011, 250 11C-acetate PET/CTAC scans were performed at a single institution on patients with prostate cancer recurrence after surgery, brachytherapy, or external beam radiation. Of these patients, 120 met our inclusion criteria. Logistic regression analysis was used to examine the relationship between predictability of positive findings and patients’ characteristics, such as prostate-specific antigen (PSA) level at the time of scan, PSA kinetics, Gleason score, staging, and type of treatment before scan. Results In total, 68.3% of the 120 11C-acetate PET/CTAC scans were positive. The percentage of positive scans and PSA at the time of scanning and PSA velocity (PSAV) had positive correlations. The putative sensitivity and specificity were 86.6% and 65.8%, respectively, when a PSA level greater than 1.24 ng/mL was used as the threshold for scanning. The putative sensitivity and specificity were 74% and 75%, respectively, when a PSAV level greater than 1.32 ng/mL/y was used as the threshold. No significant associations were found between scan positivity and age, PSA doubling time, Gleason score, staging, or type of treatment before scanning. Conclusions This retrospective study suggests that threshold models of PSA greater than 1.24 ng/mL or PSAV greater than 1.32 ng/mL per year are independent predictors of positive findings in 11C-acetate PET/CTAC imaging of recurrent prostate cancer. PMID:25036021

  20. Pulmonary aspergilloma: A rare differential diagnosis to lung cancer after positive FDG PET scan

    Directory of Open Access Journals (Sweden)

    Franziska Spycher

    2014-01-01

    Full Text Available Early diagnosis and treatment of lung cancer, one of the leading causes of cancer-related death, is important to improve morbidity and mortality. Therefore any suspect solitary pulmonary nodule should prompt the pursuit for a definitive histological diagnosis. We describe the case of a 55-years-old male ex-smoker, who was admitted to our hospital due to recurrent hemoptysis and dry cough. A CT scan showed an irregular nodule of increasing size (28 mm in diameter in the left lower lobe (LLL. A whole body PET-CT scan (643 MBq F-18 FDG i.v. was performed and confirmed an avid FDG uptake of the nodule in the LLL, highly suspicious of lung cancer, without any evidence of lymphogenic or hematogenic metastasis. Bronchoscopy was not diagnostic and due to severe adhesions after prior chest trauma and the central location of the nodule, a lobectomy of the LLL was performed. Surprisingly, histology showed a simple aspergilloma located in a circumscribed bronchiectasis with no evidence of malignancy. This is a report of an informative example of an aspergilloma, which presented with symptoms and radiological features of malignant lung cancer.

  1. Body indices and basic vital signs in Helicobacter pylori positive and negative persons

    International Nuclear Information System (INIS)

    Kopacova, Marcela; Bures, Jan; Koupil, Ilona; Rejchrt, Stanislav; Vorisek, Viktor; Seifert, Bohumil; Pozler, Oldrich; Zivny, Pavel; Douda, Tomas; Palicka, Vladimir; Holcik, Jan

    2007-01-01

    It has been hypothesized that Helicobacter pylori (Hp) infection may contribute to reduced stature, risk of hypertension or obesity. The aim was to evaluate body indices in Hp positive and negative persons. A total of 2436 subjects (4-100 years old) were tested for Hp status by 13 C-urea breath test. Data on height and weight were collected for 84%, and blood pressure for 80% of the study subjects. The prevalence of Hp infection was 41.6%. The odds ratio for a 10-year increase in age was 1.21 (95% CI 1.17-1.25, p-value <0.001). Statistically significant negative association of Hp positivity with body height was most pronounced in the younger age groups, while a positive association of Hp positivity with body mass index was only seen in those aged 15+ years. There was a negative effect of Hp positivity on systolic and diastolic blood pressure in subjects below 25 and a relatively strong positive effect on blood pressure in subjects over 65 years. Residual confounding by social characteristics as a possible explanation for the associations of Hp positivity with height and blood pressure cannot be excluded. Unmeasured factors related to social and family environment may cause the apparent association between Hp positivity and children's growth and blood pressure

  2. 46 CFR 169.831 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.831 Section 169.831 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... radio beacon (EPIRB). The master shall ensure that— (a) The EPIRB required in § 169.555 of this...

  3. Voltage directive drive with claw pole motor and control without rotor position indicator

    Science.gov (United States)

    Stroenisch, Volker Ewald

    Design and testing of a voltage directive drive for synchronous variable speed claw pole motor and control without rotor position indicator is described. Economic analysis of the designed regulation is performed. Computations of stationary and dynamic behavior are given and experimental operational behavior is determined. The motors can be used for electric transportation vehicles, diesel motors, and electric railway engines.

  4. Indications of CT scan after minor head trauma in children. Can age younger than 2 years be a risk factor?

    International Nuclear Information System (INIS)

    Ozaki, Mitsunori; Seo, Yoshinobu; Nakamura, Hirohiko

    2010-01-01

    The indications of CT scan after minor head trauma in children are often discussed, including risks of radiation-induced malignancy. Our aim is to identify whether children younger than 2 years have greater risk of traumatic brain injury compared to older children. We enrolled and analysed 1,830 patients younger than 7 years who underwent CT scans after head trauma in our institute. Patients without any symptoms (n=916) were defined as Group A (age<2: n=391, age 2-6: n=525). Patients with extracranial traumatic findings such as scalp hematoma or laceration, and without any neurological symptoms (n=600) were defined as Group B (age<2: n=163, age 2-6: n=437). In order to analyze whether children younger than 2 years have risks of abnormal CT findings due to head trauma, we used the chi-square test in both Group A and Group B. A P-value of less than 0.05 was considered statistically significant. In Group A, there was no significant difference in the frequency of abnormal CT findings between the younger and older groups (p=0.526). In Group B, however, there was a significant difference between those groups (p=0.0186). We suggest that, based on our findings, children younger than 2 years without any symptoms don't have a greater risk of brain injury compared to older children after minor head trauma. This study might contribute to save those children from receiving unnecessary radiation. (author)

  5. Is decreased diameter of renal pelvis in prone position an indicator of successful pyeloplasty?

    International Nuclear Information System (INIS)

    Sharma, Gyanendra; Sharma, Anshu; Leung, Vivian Yee-Fong; Chu, Winnie Chiu-Wing

    2016-01-01

    To evaluate patients who had undergone pyeloplasty for pelviureteric junction obstruction, by measuring the anteroposterior diameter (APD) of the renal pelvis in supine and prone positions, and determine whether a decrease in APD in prone position can exclude obstruction in dilated renal system. From January 2012 to December 2013, patients who had undergone pyeloplasty were evaluated by ultrasound in two centers. The difference of APD of the renal pelvis in supine and prone positions was obtained. Correlation was made with the pre- and post-pyeloplasty renal function by radionuclide renogram. There were 42 patients (31 males, 11 females; age range 5 months to 18 years). Residual hydronephrosis was detected in 41 patients of whom 35 patients (85%) showed decrease in APD by >10% in prone position. These patients and the one without hydronephrosis showed either no deterioration or improvement in renal function. Six patients (15%) showed either no change or increase in APD in prone position. Three patients (7.5%) were confirmed to have decrease in renal function indicating obstruction. Three patients (7.5%) showed no deterioration of renal function, but sluggish drainage on radionuclide renogram. Demonstration of decreased APD of renal pelvis in prone position by ultrasound is useful to differentiate obstructed from non-obstructed dilated renal system, and it correctly identified 85% candidates with successful pyeloplasty. In patients with no decrease or increase in APD at prone position, further follow-up is recommended to rule out obstruction

  6. A Scan for Positively Selected Genes in the Genomes of Humans and Chimpanzees

    DEFF Research Database (Denmark)

    Nielsen, Rasmus; Bustamente, Carlos; Clark, Andrew G.

    2005-01-01

    Since the divergence of humans and chimpanzees about 5 million years ago, these species have undergone a remarkable evolution with drastic divergence in anatomy and cognitive abilities. At the molecular level, despite the small overall magnitude of DNA sequence divergence, we might expect...... such evolutionary changes to leave a noticeable signature throughout the genome. We here compare 13,731 annotated genes from humans to their chimpanzee orthologs to identify genes that show evidence of positive selection. Many of the genes that present a signature of positive selection tend to be involved...

  7. An Autonomous Ultra-Wide Band-Based Attitude and Position Determination Technique for Indoor Mobile Laser Scanning

    Directory of Open Access Journals (Sweden)

    Lawrence Lau

    2018-04-01

    Full Text Available Mobile laser scanning (MLS has been widely used in three-dimensional (3D city modelling data collection, such as Google cars for Google Map/Earth. Building Information Modelling (BIM has recently emerged and become prominent. 3D models of buildings are essential for BIM. Static laser scanning is usually used to generate 3D models for BIM, but this method is inefficient if a building is very large, or it has many turns and narrow corridors. This paper proposes using MLS for BIM 3D data collection. The positions and attitudes of the mobile laser scanner are important for the correct georeferencing of the 3D models. This paper proposes using three high-precision ultra-wide band (UWB tags to determine the positions and attitudes of the mobile laser scanner. The accuracy of UWB-based MLS 3D models is assessed by comparing the coordinates of target points, as measured by static laser scanning and a total station survey.

  8. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  9. Positive Result by Serology Indicates Active Helicobacter pylori Infection in Patients with Atrophic Gastritis

    OpenAIRE

    Kokkola, Arto; Rautelin, Hilpi; Puolakkainen, Pauli; Sipponen, Pentti; Färkkilä, Martti; Haapiainen, Reijo; Kosunen, Timo U.

    1998-01-01

    Patients with atrophic corpus gastritis and elevated Helicobacter pylori antibody titers but 13C-urea breath test (13C-UBT) and histology results negative for H. pylori were randomized into eradication therapy or follow-up only. Antibody levels decreased significantly in six out of seven patients in the eradication group, while in the follow-up group, the titers declined in only one out of eight patients. In patients with atrophic corpus gastritis, positive serology results may indicate an on...

  10. Case of false positive scanning observed after radiation therapy for orbital tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, H [Gifu Prefectural Tajimi Hospital (Japan); Nakamura, K; Maeda, S; Watanabe, R; Miyajima, T

    1978-12-01

    A report was made of 56-year-old female patient of abducensparesis. In the early stage the cause remained undetermined with nothing abnormal noted in scintigraphy. Diplopia disappeared once, but right, exophalmus relapsed. In gammaencepharography, a hot spot was noted in the orbita, sinus ethmoidalis and sirus sphenoidalis. In an operation, squamous cell carcinoma was removed and radiation therapy was performed (total dose of 3520 r) and, three months later a scintigraphy disclosed a high spot of /sup 203/Hg uptake ratio in the right orbita and its lower portions. The biopsy of these portions disclosed a necrotic tissue instead of a tumor. In scintigraphy after radiation therapy against the tumor, it was reported that a positive scintigraphy was present because of the vascular trouble of said portions, although the tumor had disappeared. Attention should be given as well as an opinion of high density together with the examination by CT, especially as to enhancement.

  11. Bridging centrality: A new indicator to measure the positioning of actors in R&D networks

    Energy Technology Data Exchange (ETDEWEB)

    Scherngell, T.; Wanzenboeck, I.; Berge, L.

    2016-07-01

    In the recent past, we can observe growing interest in the STI community in the notion of positioning indicators, shifting emphasis to actors in the innovation process and their R&D inter-linkages with other actors. In relation to this, we suggest a new approach for assessing the positioning of actors relying on the notion of bridging centrality (BC). Based on the concept of bridging paths, i.e. a set of two links connecting three actors across three different aggregate nodes (e.g. organisations, regions or countries), we argue that triangulation in networks is a key issue for knowledge recombinations and the extension of an actor's knowledge base. As bridges are most often not empirically observable at the individual level of research teams, we propose an approximated BC measure that provides a flexible framework for dealing with the aggregation problem in positioning actors. Hereby, BC is viewed as a function of an aggregate node's (i) participation intensity in the network, (ii) its openness to other nodes (i.e. the relative outward orientation of network links), and iii) the diversification of links to other nodes. In doing so, we provide an integrative perspective that enables us to achieve a better understanding of the positioning of certain actors in R&D networks. An illustrative example on the co-patent network of European regions demonstrates the performance and usefulness of our BC measure for networks constructed at the aggregated level, i.e. regions in our example. A region's outward orientation and the diversification of its network links moderates the influence of regional scale on network centrality. This is a major strength of the measure, and it paves the way for future studies to examine the role of certain aggregate node's, and, by this, contributes to the debate on positioning indicators in the STI context. (Author)

  12. Value of 201Tl imaging in predicting therapeutic 131I uptake in patients with thyroglobulin-positive but 131I scan-negative differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Conlu, R.A.O.; Obaldo, J.M.

    2004-01-01

    Background: Serum thyroglobulin assay and 131Iodine (1311) whole body scan are considered complementary in detecting malignant thyroid tissue or metastases. A large number of patients, however, are encountered presenting with scan-negative, thyroglobulin-positive differentiated thyroid carcinoma posing a dilemma in therapeutic management. One of the first alternative scanning agents to be employed is 201Thallium (201Tl). Recent studies have demonstrated its usefulness in identifying lesions that are not visualized with traditional 131I whole body scan. It is not clear, however, whether 201Tl scan helps in the decision-making for subsequent 131I therapy. This study was conducted to determine if 201Tl scan can predict therapeutic 131I uptake and to define the clinical role of 201Tl scanning in these patients. Methods and results: A total of 12 patients (20-63 y/o), 5 males and 7 females, underwent surgery for differentiated thyroid cancer and all had serum thyroglobulin values above 10 ng/ml and normal TPO autoantibodies. Pre-therapy 131I scan using 111 MBq (3mCi) of 131I were obtained. As required for inclusion, all patients had negative pre-therapy scan and negative TPO autoantibody results and underwent 20lTl scanning within 3 weeks. All patients were given 131I therapy (3.7-5.5 GBq or 100-150 mCi) between one to two months after 201Tl scanning. Within a week after therapy, all patients underwent whole body 1311 scanning. 201Tl imaging demonstrated thyroid remnants in 9 out of 12 patients having positive 201Tl scan but negative pre-therapy 1311 scan. However, only 2 of the positive 201Tl scans showed 131I uptake post-therapy (positive predictive value of 20%). None of the subjects presented with a negative 201Tl scan and a positive post-therapy 131I scan. Conclusion: Our study suggests that evidence of remnants or metastases on 201Tl scanning may be an inappropriate basis for the decision to proceed with 131I therapy. The role of 20lTl imaging in this subset of

  13. Home continuous positive airway pressure for cardiopulmonary indications in infants and children.

    Science.gov (United States)

    Al-Iede, Montaha; Kumaran, Radhagini; Waters, Karen

    2018-04-30

    A number of reports exist regarding the use of continuous positive airway pressure (CPAP) to manage obstructive sleep apnoea (OSA) in children, which we term 'conventional CPAP'. In contrast, there are few reports of home CPAP use for other indications, which we have grouped under the term 'cardiopulmonary'. The aims of this study were to (1) document cardiopulmonary indications for CPAP use in a cohort of infants and children, and (2) evaluate its effectiveness in this group. Hospital records were reviewed for 645 patients who were commenced on long-term CPAP over a 10-year period at a single-tertiary hospital (Children's Hospital at Westmead). This study evaluated the group where the primary indication for CPAP was not OSA ('cardiopulmonary CPAP'). Data evaluated included: demographics, diagnoses, indications for CPAP, hours of use (compliance) and sleep study results at baseline and on CPAP. Of 645 children, 148 (23%) used home CPAP for cardiopulmonary indications; and 130 (87.8%) of these were included. For this group, mean age at CPAP initiation was 18.6 ± 33.6 months (range one week to 16.8 years). Cardiopulmonary indications for CPAP use included: primary airway diseases 65 (50%), chronic lung diseases 33 (25.4%), congenital heart disease (CHD) 20 (15.4%), and both CHD and airway malacia 12 (9.2%). All sleep study variables improved on CPAP relative to the diagnostic sleep study (p 4 h/night). Interstitial lung diseases and other cardiorespiratory disorders, often of congenital origin, can be effectively treated with home CPAP whether they are associated with OSA or not. Sleep studies demonstrated improved gas exchange, sleep and reduced work of breathing with CPAP use. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Different nutritional-state indicators of HIV-positive individuals undergoing antiretroviral therapy

    Directory of Open Access Journals (Sweden)

    J. Geraix

    2008-01-01

    Full Text Available This study aimed at learning about the nutritional profile of HIV-positive individuals undergoing antiretroviral therapy and at comparing the performance of nutritional-state indicators. A transversal study was performed on 94 patients attending the Tropical Diseases Outpatient Hospital of Botucatu Medical School (FMB - UNESP. The body mass index (BMI and the classification by Papini-Berto (PB were used to evaluate nutritional state, aiming at detecting malnutrition and obesity. The waist-to-hips ratio (W/HR and waist circumference (WC were adopted for identification of abdominal obesity and lipodystrophy. According to BMI, most of the individuals were eutrophic, followed by 30.9% overweight and 6.4% malnourished. By using the PB classification, the frequency of malnourished increased (22.3%. The analysis of the PB classification in relation to BMI indicated that the former presented high sensitivity and good specificity for malnutrition diagnosis, namely 100% and 83%, respectively. The prevalence of abdominal obesity was 7.44% according to WC, and a higher prevalence (38.3% was observed when taking W/HR into account. There was significant positive association between nutritional diagnosis according to PB and T CD4+ lymphocyte. The results support the use of PB classification for malnutrition detection as well as that of BMI and W/HR for overweight and fat redistribution.

  15. Measuring socio-economic position in dietary research: is choice of socio-economic indicator important?

    Science.gov (United States)

    Turrell, Gavin; Hewitt, Belinda; Patterson, Carla; Oldenburg, Brian

    2003-04-01

    To examine the association between socio-economic position (SEP) and diet, by assessing the unadjusted and simultaneously adjusted (independent) contributions of education, occupation and household income to food purchasing behaviour. The sample was randomly selected using a stratified two-stage cluster design, and the response rate was 66.4%. Data were collected by face-to-face interview. Food purchasing was examined on the basis of three composite indices that reflected a household's choice of grocery items (including meat and chicken), fruit and vegetables. Brisbane City, Australia, 2000. : Non-institutionalised residents of private dwellings located in 50 small areas (Census Collectors Districts). When shopping, respondents in lower socio-economic groups were less likely to purchase grocery foods that were high in fibre and low in fat, salt and sugar. Disadvantaged groups purchased fewer types of fresh fruits and vegetables, and less often, than their counterparts from more advantaged backgrounds. When the relationship between SEP and food purchasing was examined using each indicator separately, education and household income made an unadjusted contribution to purchasing behaviour for all three food indices; however, occupation was significantly related only with the purchase of grocery foods. When education and occupation were simultaneously adjusted for each other, the socio-economic patterning with food purchase remained largely unchanged, although the strength of the associations was attenuated. When household income was introduced into the analysis, the association between education, occupation and food purchasing behaviour was diminished or became non-significant; income, however, showed a strong, graded association with food choice. The food purchasing behaviours of socio-economically disadvantaged groups were least in accord with dietary guideline recommendations, and hence are more consistent with greater risk for the development of diet

  16. Segmentation of Planar Surfaces from Laser Scanning Data Using the Magnitude of Normal Position Vector for Adaptive Neighborhoods.

    Science.gov (United States)

    Kim, Changjae; Habib, Ayman; Pyeon, Muwook; Kwon, Goo-rak; Jung, Jaehoon; Heo, Joon

    2016-01-22

    Diverse approaches to laser point segmentation have been proposed since the emergence of the laser scanning system. Most of these segmentation techniques, however, suffer from limitations such as sensitivity to the choice of seed points, lack of consideration of the spatial relationships among points, and inefficient performance. In an effort to overcome these drawbacks, this paper proposes a segmentation methodology that: (1) reduces the dimensions of the attribute space; (2) considers the attribute similarity and the proximity of the laser point simultaneously; and (3) works well with both airborne and terrestrial laser scanning data. A neighborhood definition based on the shape of the surface increases the homogeneity of the laser point attributes. The magnitude of the normal position vector is used as an attribute for reducing the dimension of the accumulator array. The experimental results demonstrate, through both qualitative and quantitative evaluations, the outcomes' high level of reliability. The proposed segmentation algorithm provided 96.89% overall correctness, 95.84% completeness, a 0.25 m overall mean value of centroid difference, and less than 1° of angle difference. The performance of the proposed approach was also verified with a large dataset and compared with other approaches. Additionally, the evaluation of the sensitivity of the thresholds was carried out. In summary, this paper proposes a robust and efficient segmentation methodology for abstraction of an enormous number of laser points into plane information.

  17. Segmentation of Planar Surfaces from Laser Scanning Data Using the Magnitude of Normal Position Vector for Adaptive Neighborhoods

    Directory of Open Access Journals (Sweden)

    Changjae Kim

    2016-01-01

    Full Text Available Diverse approaches to laser point segmentation have been proposed since the emergence of the laser scanning system. Most of these segmentation techniques, however, suffer from limitations such as sensitivity to the choice of seed points, lack of consideration of the spatial relationships among points, and inefficient performance. In an effort to overcome these drawbacks, this paper proposes a segmentation methodology that: (1 reduces the dimensions of the attribute space; (2 considers the attribute similarity and the proximity of the laser point simultaneously; and (3 works well with both airborne and terrestrial laser scanning data. A neighborhood definition based on the shape of the surface increases the homogeneity of the laser point attributes. The magnitude of the normal position vector is used as an attribute for reducing the dimension of the accumulator array. The experimental results demonstrate, through both qualitative and quantitative evaluations, the outcomes’ high level of reliability. The proposed segmentation algorithm provided 96.89% overall correctness, 95.84% completeness, a 0.25 m overall mean value of centroid difference, and less than 1° of angle difference. The performance of the proposed approach was also verified with a large dataset and compared with other approaches. Additionally, the evaluation of the sensitivity of the thresholds was carried out. In summary, this paper proposes a robust and efficient segmentation methodology for abstraction of an enormous number of laser points into plane information.

  18. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  19. Influence of metabolic indicators, smoking, alcohol and socioeconomic position on mortality after breast cancer

    DEFF Research Database (Denmark)

    Larsen, Signe Benzon; Kroman, Niels; Ibfelt, Else Helene

    2015-01-01

    BACKGROUND: Factors differently distributed among social groups like obesity, metabolic syndrome, diabetes, smoking, and alcohol intake predict survival after breast cancer diagnosis and therefore might mediate part of the observed social inequality in survival. MATERIAL AND METHODS: We conducted...... a cohort study among 1250 postmenopausal breast cancer patients identified among 29 875 women in the Danish Diet, Cancer and Health Study. Participants completed questionnaires and anthropometric measurements were made at enrollment. Information on survival, socioeconomic position, and comorbidity...... circumference and diabetes, and smoking and alcohol affected but did not explain the social gradient. CONCLUSION: The findings indicate that these factors explain some but not all the social inequality in survival after breast cancer and that improvement of lifestyle to some extent would improve survival among...

  20. Indication, organization, practical implementation and interpretation guidelines for retrospective CGM recording: A French position statement.

    Science.gov (United States)

    Joubert, M; Baillot-Rudoni, S; Catargi, B; Charpentier, G; Esvant, A; Franc, S; Guerci, B; Guilhem, I; Melki, V; Merlen, E; Penfornis, A; Renard, E; Riveline, J P; Schaepelynck, P; Sola-Gazagnes, A; Hanaire, H

    2015-12-01

    The benefits of retrospective continuous glucose monitoring (retroCGM) recording have been widely explored in clinical studies, and many diabetes physicians routinely use this examination. However, the method of interpretation of CGM recordings has never been precisely described. An expert French panel of physicians met for two days to discuss several aspects of retroCGM use and to produce a position statement. The guidelines cover the indications for retroCGM, the general organization and practical implementation of CGM recordings, a description of the different devices available and guidelines for the interpretation of retroCGM recordings. This consensus document should help clinicians in the proper use of retroCGM. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Play and optimal welfare: Does play indicate the presence of positive affective states?

    Science.gov (United States)

    Ahloy-Dallaire, Jamie; Espinosa, Julia; Mason, Georgia

    2017-11-16

    Play is commonly used to assess affective states in both humans and non-human animals. Play appears to be most common when animals are well-fed and not under any direct threats to fitness. Could play and playfulness therefore indicate pre-existing positive emotions, and thence optimal animal welfare? We examine this question by surveying the internal and external conditions that promote or suppress play in a variety of species, starting with humans. We find that negative affective states and poor welfare usually do suppress play (although there are notable exceptions where the opposite occurs). Furthermore, research in children suggests that beyond the frequency or total duration of play, poor welfare may additionally be reflected in qualitative aspects of this heterogeneous behaviour (e.g. display of solitary over social play; and the 'fragmentation' of play bouts) that are often overlooked in animals. There are surprisingly few studies of play in subjects with pre-existing optimal welfare or in unambiguously highly positive affective states, making it currently impossible to determine whether play can distinguish optimal or good welfare from merely neutral welfare. This therefore represents an important and exciting area for future research. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Association between red blood cell indices and CD4 count in HIV-positive reproductive women

    Science.gov (United States)

    Lumbanraja, S. N.; Siregar, D. I. S.

    2018-03-01

    Red blood cell indices, hemoglobin, and hematocrit reflect rapidity of HIV disease progression. This study aims to determine red blood cell indices and CD4 count in HIV-positive reproductive women. This study was a cross sectional study conducted at AIDS outpatient clinic at Haji Adam Malik General Hospital, Medan Indonesia. All seropositive reproductive women within antiretroviral therapy consented for blood count and CD4 examination. Data were collected and analyzed with SPSS 19. In subjects with CD4≤350 mm3, mean hemoglobin was 10.95 ± 2.01, hematocrit was 31.83 ± 5.04%, MCV was 84.17 ± 11.41, MCH was 25.98 ± 2.65, and MCHC was 32.18 ± 2.17. Mean hemoglobin, hematocrit, and MCH value was significantly lower in subjects with CD4 ≤350 mm3 (p=0.014; p=0.001; p=0.01; respectively). Lower Hb, Ht, and MCH associated with thelower CD4 count.

  3. Biochemical aspects of the neoplastic cell in relation to positive indicators

    International Nuclear Information System (INIS)

    Strom, R.

    1975-01-01

    In scintigraphic diagnoses with positive indicators, the capacity of these indicators to fix themselves or to selectively concentrate in the neoplastic tissue is utilized. This selectivity could be due to several biochemical peculiarities of the tumor cells in relation to surrounding cells: the presence on the membrane of particular chemical groups which allow these cells to invade adjacent tissue without being subject to contact inhibition; the presence on these same membranes of antigenic determinants which are particular to these cells and which can be revealed with specific antibodies; a high concentration of nucleic acid in tumor cells, with the associated possibility of fixing substances having a particular tropism for nucleic acids or for their chemical constituents; an elevated rate of nucleic acid synthesis, with an associated increase in the incorporation of precursors and also of substances which specifically interfere with this biochemical pathway; in numerous cases, tumor cells produce high quantities of acidic metabolites which must be neutralized by equivalent quantities of anions, the latter entering the cells by active transport phenomena; in tumors which develop particularly rapidly, there is a development of degenerative processes with an accumulation of degradation products; in metastatic tumors, the cells have metabolic and biosynthetic activities which are a function of the original tissue, with the possiblity of a clear metabolic difference in relation to adjacent tissues [fr

  4. Pattern of Prostate-Specific Antigen (PSA) Failure Dictates the Probability of a Positive Bone Scan in Patients With an Increasing PSA After Radical Prostatectomy

    Science.gov (United States)

    Dotan, Zohar A.; Bianco, Fernando J.; Rabbani, Farhang; Eastham, James A.; Fearn, Paul; Scher, Howard I.; Kelly, Kevin W.; Chen, Hui-Ni; Schöder, Heiko; Hricak, Hedvig; Scardino, Peter T.; Kattan, Michael W.

    2007-01-01

    Purpose Physicians often order periodic bone scans (BS) to check for metastases in patients with an increasing prostate-specific antigen (PSA; biochemical recurrence [BCR]) after radical prostatectomy (RP), but most scans are negative. We studied patient characteristics to build a predictive model for a positive scan. Patients and Methods From our prostate cancer database we identified all patients with detectable PSA after RP. We analyzed the following features at the time of each bone scan for association with a positive BS: preoperative PSA, time to BCR, pathologic findings of the RP, PSA before the BS (trigger PSA), PSA kinetics (PSA doubling time, PSA slope, and PSA velocity), and time from BCR to BS. The results were incorporated into a predictive model. Results There were 414 BS performed in 239 patients with BCR and no history of androgen deprivation therapy. Only 60 (14.5%) were positive for metastases. In univariate analysis, preoperative PSA (P = .04), seminal vesicle invasion (P = .02), PSA velocity (P < .001), and trigger PSA (P < .001) predicted a positive BS. In multivariate analysis, only PSA slope (odds ratio [OR], 2.71; P = .03), PSA velocity (OR, 0.93; P = .003), and trigger PSA (OR, 1.022; P < .001) predicted a positive BS. A nomogram for predicting the bone scan result was constructed with an overfit-corrected concordance index of 0.93. Conclusion Trigger PSA, PSA velocity, and slope were associated with a positive BS. A highly discriminating nomogram can be used to select patients according to their risk for a positive scan. Omitting scans in low-risk patients could reduce substantially the number of scans ordered. PMID:15774789

  5. Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn.

    Science.gov (United States)

    van der Beek, Feddo B; Briaire, Jeroen J; van der Marel, Kim S; Verbist, Berit M; Frijns, Johan H M

    2016-01-01

    In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and the distance to the modiolus of each electrode contact were determined using high-resolution CT scanning. The threshold levels (T-levels) and maximum comfort levels (M-levels) at 1 year of follow-up were determined. The degree of speech perception of the subjects was evaluated during routine clinical follow-up. The depths of insertion of all the electrode contacts were determined. The distance to the modiolus was significantly smaller at the basal and apical cochlear parts compared with that at the middle of the cochlea (p basal end of the cochlea (3.4 dB). Additionally, the M-levels, which were fitted in our clinic using a standard profile, also increased toward the basal end, although with a lower amplitude (1.3 dB). Accordingly, the dynamic range decreased toward the basal end (2.1 dB). No correlation was found between the distance to the modiolus and the T-level or the M-level. Furthermore, the correlation between the insertion depth and stimulation levels was not affected by the duration of deafness, age at implantation or the time since implantation. Additionally, the T-levels showed a significant correlation with the speech perception scores (p stimulation levels of the cochlear implants were affected by the intracochlear position of the electrode contacts, which were determined using postoperative CT scanning. Interestingly, these levels depended on the insertion depth, whereas the distance to the modiolus did not affect the stimulation levels. The T-levels increased toward the basal end of the cochlea. The level profiles were independent of the overall stimulation levels and were not affected by the biographical data of the patients, such as the duration of deafness, age at

  6. Development of a Nomogram Model Predicting Current Bone Scan Positivity in Patients Treated with Androgen-Deprivation Therapy for Prostate Cancer

    Science.gov (United States)

    Gotto, Geoffrey T.; Yu, Changhong; Bernstein, Melanie; Eastham, James A.; Kattan, Michael W.

    2014-01-01

    Purpose: To develop a nomogram predictive of current bone scan positivity in patients receiving androgen-deprivation therapy (ADT) for advanced prostate cancer; to augment clinical judgment and highlight patients in need of additional imaging investigations. Materials and methods: A retrospective chart review of bone scan records (conventional 99mTc-scintigraphy) of 1,293 patients who received ADT at the Memorial Sloan-Kettering Cancer Center from 2000 to 2011. Multivariable logistic regression analysis was used to identify variables suitable for inclusion in the nomogram. The probability of current bone scan positivity was determined using these variables and the predictive accuracy of the nomogram was quantified by concordance index. Results: In total, 2,681 bone scan records were analyzed and 636 patients had a positive result. Overall, the median pre-scan prostate-specific antigen (PSA) level was 2.4 ng/ml; median PSA doubling time (PSADT) was 5.8 months. At the time of a positive scan, median PSA level was 8.2 ng/ml; 53% of patients had PSA <10 ng/ml; median PSADT was 4.0 months. Five variables were included in the nomogram: number of previous negative bone scans after initiating ADT, PSA level, Gleason grade sum, and history of radical prostatectomy and radiotherapy. A concordance index value of 0.721 was calculated for the nomogram. This was a retrospective study based on limited data in patients treated in a large cancer center who underwent conventional 99mTc bone scans, which themselves have inherent limitations. Conclusion: This is the first nomogram to predict current bone scan positivity in ADT-treated prostate cancer patients, providing high predictive accuracy. PMID:25386410

  7. Development of a nomogram model predicting current bone scan positivity in patients treated with androgen-deprivation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Michael eKattan

    2014-10-01

    Full Text Available Purpose: To develop a nomogram predictive of current bone scan positivity in patients receiving androgen-deprivation therapy (ADT for advanced prostate cancer; to augment clinical judgment and highlight patients in need of additional imaging investigations.Materials and Methods: A retrospective chart review of bone scan records (conventional 99mTc-scintigraphy of 1,293 patients who received ADT at the Memorial Sloan-Kettering Cancer Center from 2000 to 2011. Multivariable logistic regression analysis was used to identify variables suitable for inclusion in the nomogram. The probability of current bone scan positivity was determined using these variables and the predictive accuracy of the nomogram was quantified by concordance index.Results: In total, 2,681 bone scan records were analyzed and 636 patients had a positive result. Overall, the median pre-scan prostate-specific antigen (PSA level was 2.4 ng/ml; median PSA doubling time (PSADT was 5.8 months. At the time of a positive scan, median PSA level was 8.2 ng/ml; 53% of patients had PSA <10 ng/ml; median PSADT was 4.0 months. Five variables were included in the nomogram: number of previous negative bone scans after initiating ADT, PSA level, Gleason grade sum, and history of radical prostatectomy and radiotherapy. A concordance index value of 0.721 was calculated for the nomogram. This was a retrospective study based on limited data in patients treated in a large cancer centre who underwent conventional 99mTc bone scans, which themselves have inherent limitations. Conclusions: This is the first nomogram to predict current bone scan positivity in ADT-treated prostate cancer patients, providing high predictive accuracy.

  8. Trophic position of soil nematodes in boreal forests as indicated by stable isotope analysis

    Science.gov (United States)

    Kudrin, Alexey; Tsurikov, Sergey

    2016-04-01

    Despite the well-developed trophic classification of soil nematodes, their position in soil food webs is still little understood. Observed deviations from the typical feeding strategy indicate that a simplified trophic classification probably does not fully reflect actual trophic interactions. Furthermore, the extent and functional significance of nematodes as prey for other soil animals remains unknown. Stable isotope analysis (SIA) is powerful tool for investigating the structure of soil food webs, but its application to the study of soil nematodes has been limited to only a few studies. We used stable isotope analysis to gain a better understanding of trophic links of several groups of soil nematodes in two boreal forests on albeluvisol. We investigated four taxonomic groups of nematodes: Mononchida, Dorylaimida, Plectidae and Tylenchidae (mostly from the genus Filenchus), that according to the conventional trophic classification represent predators, omnivores, bacterivores and root-fungal feeders, respectively. To assess the trophic position of nematodes, we used a comparison against a set of reference species including herbivorous, saprophagous and predatory macro-invertebrates, oribatid and mesostigmatid mites, and collembolans. Our results suggest that trophic position of the investigated groups of soil nematodes generally corresponds to the conventional classification. All nematodes were enriched in 13C relative to Picea abies roots and litter, and mycorrhizal fungal mycelium. Root-fungal feeders Tylenchidae had δ15N values similar to those of earthworms, enchytraeids and Entomobrya collembolans, but slightly lower δ13C values. Bacterivorous Plectidae were either equal or enriched in 15N compared with saprophagous macroinvertebrates and most mesofauna species. Omnivorous Dorylaimida and predatory Mononchida were further enriched in 15N and their isotopic signature was similar to that of predatory arthropods. These data confirm a clear separation of

  9. [Indications and instructions to patients for a positron emission tomography-PET scan. The importance of the hybridic PET/CT-computerised tomography scan and which specialty should be responsible for its function].

    Science.gov (United States)

    Grammaticos, Philip; Datseris, Ioannis; Gerali, Sofia; Papantoniou, Vassilios; Valsamaki, Pipitsa; Boundas, Dimitrios

    2007-01-01

    Indications and instructions to patients for performing a positron emission tomography - PET scan are mentioned. Although PET camera was developed in 1970 its clinical indications were established in about 1998. The hybridic PET/CT- computerized tomography scanner appeared in 2001 and its clinical indications are still under discussion. These discussions refer to both the use of PET/CT as an acquisition correction and anatomic localization device for PET images (AC/A) and to its use as a diagnostic CT scan (dCT). Most of the patients submitted for a PET scan have already done a dCT scan. This was the case in 286 out of the first 300 patients referred to "Evangelismos" hospital in Athens for a PET scan. These two scans can be matched electronically. Extra cost, space, personnel and radiation absorption dose especially in children, are additional factors to be considered in using the PET/CT scanner. The specialty of Nuclear Medicine is now based on the PET camera, its best part and main equipment for molecular imaging. It is very much easier and faster for a Nuclear Medicine physician who routinely reports tomographic PET and SPET images, to be familiar with the CT images than for a Radiologist to get to "know how" about the PET camera and the whole Nuclear Medicine Department. Nuclear Medicine is about open radiation sources, molecular imaging, specific radio-pharmacology, radiobiology, radiation protection etc, while on the other hand in some countries, Nuclear Physicians have already spent, as part of their official training, six months in a Radiology Department whose function is considered to be at least 25% about the CT scanner. We come to the conclusion that the PET/CT scanner should be under the responsibility of the Nuclear Medicine Department and the Radiologist should act as an advisor.

  10. Influence of Peer Social Experiences on Positive and Negative Indicators of Mental Health among High School Students

    Science.gov (United States)

    Suldo, Shannon M.; Gelley, Cheryl D.; Roth, Rachel A.; Bateman, Lisa P.

    2015-01-01

    Modern definitions of complete mental health include both positive and negative indicators of psychological functioning. We examined the associations between peer relationships (victimization and receipt of prosocial acts) and multiple indicators of mental health that represent subjective well-being (i.e., life satisfaction, positive and negative…

  11. Positive selection in octopus haemocyanin indicates functional links to temperature adaptation.

    Science.gov (United States)

    Oellermann, Michael; Strugnell, Jan M; Lieb, Bernhard; Mark, Felix C

    2015-07-05

    Octopods have successfully colonised the world's oceans from the tropics to the poles. Yet, successful persistence in these habitats has required adaptations of their advanced physiological apparatus to compensate impaired oxygen supply. Their oxygen transporter haemocyanin plays a major role in cold tolerance and accordingly has undergone functional modifications to sustain oxygen release at sub-zero temperatures. However, it remains unknown how molecular properties evolved to explain the observed functional adaptations. We thus aimed to assess whether natural selection affected molecular and structural properties of haemocyanin that explains temperature adaptation in octopods. Analysis of 239 partial sequences of the haemocyanin functional units (FU) f and g of 28 octopod species of polar, temperate, subtropical and tropical origin revealed natural selection was acting primarily on charge properties of surface residues. Polar octopods contained haemocyanins with higher net surface charge due to decreased glutamic acid content and higher numbers of basic amino acids. Within the analysed partial sequences, positive selection was present at site 2545, positioned between the active copper binding centre and the FU g surface. At this site, methionine was the dominant amino acid in polar octopods and leucine was dominant in tropical octopods. Sites directly involved in oxygen binding or quaternary interactions were highly conserved within the analysed sequence. This study has provided the first insight into molecular and structural mechanisms that have enabled octopods to sustain oxygen supply from polar to tropical conditions. Our findings imply modulation of oxygen binding via charge-charge interaction at the protein surface, which stabilize quaternary interactions among functional units to reduce detrimental effects of high pH on venous oxygen release. Of the observed partial haemocyanin sequence, residue 2545 formed a close link between the FU g surface and the

  12. The value of indicated computed tomography scan of the chest and abdomen in addition to the conventional radiologic work-up for blunt trauma patients.

    NARCIS (Netherlands)

    Deunk, J.; Dekker, H.M.; Brink, M.; Vugt, R. van; Edwards, M.J.R.; Vugt, A.B. van

    2007-01-01

    BACKGROUND: Multidetector computed tomography (CT) is more sensitive and specific in detecting traumatic injuries than conventional radiology is. However, still little is known about the diagnostic value and the therapeutic impact of indicated thoraco-abdominal CT scan when it is performed in

  13. Position of lung scintigraphy in emergency diagnosis and therapeutic indications in cases of severe pulmonary embolism

    International Nuclear Information System (INIS)

    Torquat, Sabine de.

    1975-01-01

    The position of lung scintigraphy in diagnostic strategy is discussed. This technique appears to afford the key examination in severe pulmonary embolism because of its qualities, which are: - speed of execution, - absolute harmlessness, - diagnostic safety. Taking these points in order: - speed of execution is ensured by the very rapid uptake of I 131-labelled albumin macroaggregates (usable immediately) and the existence of the gamma camera; - harmlessness of the examination by the use of non-allergenic radioactive tracers and doses not significantly restricting the vascular bed still perfused; whichever of the two possible techniques is employed (scanner and gamma camera) the examination can always be practised without getting the patient out of bed, which avoids the risk of clot migration due to movement; - certainty of the result by the fact that in the event of a surgical indication the circulation cut-off image is spectacular and obvious in fact a lung amputation image must be equal to or greater than 50% of the pulmonary field before an operation is decided upon all other images remaining within the scope of a hypocoagulant treatment. A study was carried out in a cardio-vascular surgery department on 28 patients hospitalised with a possible view to embolectomy. Lung scintigraphy allows a quick exploration of the minor circulation. In the special clinical situation of the patients, for whom the advisability of an embolectomy is discussed, the scintigraphic examination provides the key: if normal it eliminates the diagnosis absolutely; if not it reveals without extra risk the spectacular obliterations of the vascular bed on which any therapeutic decision, medical or surgical is based [fr

  14. Analysis of magnetic field and hysteresis of reed switches for control rod position indicator of SMART CEDM

    International Nuclear Information System (INIS)

    Yoo, J. W.; Kim, J. H.; Heo, H.; Kim, J. I.; Jang, M. H.

    2002-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The control rod position indicator having the high performance for SMART was developed on the basis of RSPT technology identified through the survey. The hysteresis of reed switches is one of the important factors in a repeat accuracy of control rod position indication. In this study, the hysteresis of reed switches is introduced and the design method using the magnetic analysis of reed switches in presented

  15. Bone position emission tomography with or without CT Is more accurate than bone scan for detection of bone metastasis

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Lee, Wom Woo; Kim, Sang Eun

    2013-01-01

    Na1 8F bone positron emission tomography (bone PET) is a new imaging modality which is useful for the evaluation of bone diseases. Here, we compared the diagnostic accuracies between bone PET and bone scan for the detection of bone metastasis (BM). Sixteen cancer patients (M:F = 10:6, mean age = 60 ± 12 years) who underwent both bone PET and bone scan were analyzed. Bone PET was conducted 30 minutes after the injection of 370 MBq Na1 8F , and a bone scan was performed 3 hours after the injection of 1295 MBq 9 9mT c-hydroxymethylene diphosphonate. In the patient-based analysis (8 patients with BM and 8 without BM), the sensitivities of bone PET (100% 8/8) and bone scan (87.5% = 7/8) were not significantly different (p > 0.05), whereas the specificity of bone PET (87.5% = 7/8) was significantly greater than that of the bone scan (25% = 2/8) (p 8F bone PET is more accurate than bone scan for BM evaluation.

  16. Innovation indices: the need for positioning them where they properly belong.

    Science.gov (United States)

    Kozłowski, Jan

    A specific quality of the discussion about innovation indices (scoreboards) is that more often than not the subject is dealt with from a purely technical point of view. Such a narrow approach silently assumes that indices used as a policy tool are an accurate reflection of the phenomenon and should not be questioned, and also that the whole discussion concerning them should refer to methodological aspects and is best left to the statisticians. This author is of the opinion that for an accurate evaluation of the value of indices as a policy tool, it is necessary to consider the matter from the broader point of view and from the context in which such indices are generated and used. This article puts forward the thesis that progress in science and innovation policy studies depends on a diversity of issues, approaches and perspectives. If that is the case, maintaining thematic and methodological variety may be more important than creating coherent and closed analytical tools, i.e. indices. The advantage of indices is that they focus attention on those variables which are deemed to be key. Among their disadvantages, however, are their highly abstract nature (in order to understand innovation-related phenomena, it is necessary to study them in tangible, composite forms); their tendency to skip unmeasurable determinants; their prior acceptance of definitions and concepts of innovation (instead of searching for them); the way they apply a single yardstick to diverse countries and regions, assumed linearity and causality in a complex and non-linear world, the way they direct policy towards implementing indicators (rather than identifying and solving problems). It is suggested that big data revolution will allow the emergence of a new measurement tools that will replace innovation indices.

  17. Experimental determination of spectral indices by scanning of fuel rod in the IPEN/MB-01 reactor

    International Nuclear Information System (INIS)

    Fanaro, Leda Cristina Cabelo Bernardes

    2009-01-01

    In this work, the spectral indexes 28ρ * and 25δ * , and gamma efficiency factor in the IPEN/MB-01 reactor were determined experimentally employing a rod scanning technique. In the case of 28ρ * , this method has the advantage of eliminating most of the correction factors derived from the calculations. Only the fission yield factor and the relative fission rate in the 235 U remain in the determination of the 25δ * . The experiments were performed with different thicknesses of cadmium sleeves: 0.55 mm, 1.10 mm and 2.20 mm. The final experimental uncertainty achieved in the experiment, less that 1 %, and the excellent geometrical and material data characterization of the IPEN/MB-01 reactor allow to use the results as benchmark for validate calculation methods and related nuclear data libraries. The comparison between calculated values and experimental values was performed by employing the MCNP-5 code and the nuclear data libraries: ENDF/B-VI.8, ENDF/B-VII.0, JENDL-3.3 and JEFF-3.1. The results demonstrate that the difference among libraries is very small. Also, the comparison between calculated values and experimental values shows that there has been considerable progress in the recent nuclear data libraries. The best result is obtained with ENDF/B-VII.0 nuclear data library, and the highest discrepancy was obtained with JEFF-3.1 and JENDL-3.3 nuclear data libraries. (author)

  18. Left ventricular filling rate change as an earlier indicator than ejection fraction of chemotherapeutic cardiotoxicity in cancer paptents' nuclear medicine MUGA scans

    International Nuclear Information System (INIS)

    Miko, T.G.

    2004-01-01

    According to Wang Siegel has long suggested that an earlier indicator of damage to the hearts of cancer patients undergoing potentially cardiotoxic chemotherapy could be change in the left ventricular filling rate (LVFT) rather than dependence on the left ventricular ejection fraction (LVEF) as a measure for when to discontinue chemotherapy. Currently ejection fraction obtained by performing the nuclear medicine MUGA scan is the gold standard for determining further treatment of patients with these cardiotoxic agents. We are seeking to see if changes in filling rate (LVFR) are an earlier indicator of cardiotoxicity by performing a retrospective analysis of MUGA scans performed at our facility pre- and post-chemotherapy and performing a statistical analysis of changes in ejection fraction us filling rate in patients known to have cardiotoxic changes due to chemotherapy. (authors)

  19. DISCRIMINATIVE MODEL OF CERTAIN MOTOR INDICATORS OF FOOTBALL PLAYERS AS SELECTION CRITERIA FOR TEAM POSITION

    Directory of Open Access Journals (Sweden)

    Goran Vučković

    2013-07-01

    Full Text Available Well-designed and implemented selection is one of the important prerequisites for achieving the expected results in the modern competitive sport at all levels. The aim of this work was to determine how the selection was made for Serbian League players, on the basis of their certain motor parameters and the positions in the team. A sample of 25 senior players of a football team competing in the Serbian League is divided into four sub-samples, based on team positions. For assessment of motor characteristics following tests were used: long jump (LJ, Abalac test (AT; 10 seconds push-ups (PU, 30 seconds trunk bends (TB, 20 meter flying start running (20FSR, 20 meter high start running (20HSR, 50 meter high start running (50HSR and Cooper test (CT . Based on the obtained results it can be concluded that there are significant differences for variable 20FSR and variable CT (F = 3754, 9835, p = .027, .000, respectively. Three canonical discriminant functions were singled out, where the first explained even 84.6%, the second 14.5% and the third only 1% of the total variance, or in summary first two functions explained 99.0% of the variance. It can be concluded that the selected players, in terms of the position in the team, distinguished first by performing on the Cooper test, followed by the result of 20 meter flying start running, 20 meter high start running, 50 meter high start running, trunk bends, and finally by Abalac test, push-ups and long jump. Observed as a function of certain motor characteristics, it could be concluded that in the selection of players in terms of the playing position confidence level was 72.0% in general level, with the most reliable for goalkeepers (100%, midfielders (71.4% and defensive players (70.0%, while the smallest was at strikers (50%.

  20. Assessment of child psychomotor development in population groups as a positive health indicator.

    Science.gov (United States)

    Lejarraga, Horacio; Kelmansky, Diana M; Passcucci, María C; Masautis, Alicia; Insua, Iván; Lejarraga, Celina; Nunes, Fernando

    2016-02-01

    It is necessary to use health indicators describing the conditions of all individuals in a population, not just of those who have a disease or die. To introduce a method to collect population indicators of psychomotor development in children younger than 6 years old and show its results. Data were obtained from a cross-sectional assessment regarding compliance with 13 developmental milestones (selected from the national reference) conducted in 5465 children using five surveys administered by the Matanza-Riachuelo River Basin Authority in areas of this basin where a high proportion of families with unmet basic needs live. For each survey, a logistic regression analysis was used to estimate the median age at attainment of the 13 developmental milestones. A linear regression model between the estimated age at attainment of the 13 milestones was adjusted for each survey based on the corresponding age at attainment of the national reference. Based on this model, three indicators were defined: overall developmental quotient, developmental quotient at 4 years old, and developmental trend. Results from the five surveys ranged between 0.74 and 0.85, 0.88 and 0.81, and -0.15 and -0.26 for the overall developmental quotient, developmental quotient at 4 years old, and developmental trend, respectively. A distinct developmental delay and an increasing trend in delay with age were observed. Indicators are easily interpreted and related to social indicators (unmet basic needs, etc.). Collecting the information necessary to make estimations takes little time and can be applied to population groups, but not on an individual level. Sociedad Argentina de Pediatría.

  1. Animation as a Visual Indicator of Positional Uncertainty in Geographic Information

    DEFF Research Database (Denmark)

    Kessler, Carsten; Lotstein, Enid

    2018-01-01

    Effectively communicating the uncertainty that is inherent in any kind of geographic information remains a challenge. This paper investigates the efficacy of animation as a visual variable to represent positional uncertainty in a web mapping context. More specifically, two different kinds...... of animation (a ‘bouncing’ and a ‘rubberband’ effect) have been compared to two static visual variables (symbol size and transparency), as well as different combinations of those variables in an online experiment with 163 participants. The participants’ task was to identify the most and least uncertain point...... visualizations using symbol size and transparency. Somewhat contradictory to those results, the participants showed a clear preference for those static visualizations....

  2. The image of Russia in 2010—2011 international indices: positioning crisis

    Directory of Open Access Journals (Sweden)

    Berendeev Mikhail

    2011-09-01

    Full Text Available This paper considers the political and economic shortcomings of the image of Russia and its perception by the international community in 2010—2011. International indices are a comprehensive information source in terms of the economic and political image of a country and, to a great extent, a decisive factor in the global trends relevant to different countries and their development potentials. The author also compares the international images of Russia and the Baltic Sea region countries.

  3. A False Positive {sup 18}F-FDG PET/CT Scan Caused by Breast Silicone Injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chao Jung; Lee, Bi Fang; Yao, Wei Jen; Wu, Pei Shan; Chen, Wen Chung; Peng, Shu Lin; Chiu, Nan Tsing [Cheng Kung University Medical College and Hospital, Tainan (Turkmenistan)

    2009-04-15

    We present here the case of a 40-year-old woman with a greater than 10 year prior history of bilateral breast silicone injection and saline bag implantation. Bilateral palpable breast nodules were observed, but the ultrasound scan was suboptimal and the magnetic resonance imaging showed no gadolinium enhanced tumor. The {sup 18}F-FDG PET/CT scan showed a hypermetabolic nodule in the left breast with a 30% increase of {sup 18}F-FDG uptake on the delayed imaging, and this mimicked breast cancer. She underwent a left partial mastectomy and the pathology demonstrated a siliconoma.

  4. Indications of a positive feedback between coastal development and beach nourishment

    Science.gov (United States)

    Armstrong, Scott B.; Lazarus, Eli D.; Limber, Patrick W.; Goldstein, Evan B.; Thorpe, Curtis; Ballinger, Rhoda C.

    2016-12-01

    Beach nourishment, a method for mitigating coastal storm damage or chronic erosion by deliberately replacing sand on an eroded beach, has been the leading form of coastal protection in the United States for four decades. However, investment in hazard protection can have the unintended consequence of encouraging development in places especially vulnerable to damage. In a comprehensive, parcel-scale analysis of all shorefront single-family homes in the state of Florida, we find that houses in nourishing zones are significantly larger and more numerous than in non-nourishing zones. The predominance of larger homes in nourishing zones suggests a positive feedback between nourishment and development that is compounding coastal risk in zones already characterized by high vulnerability.

  5. Chronic Latent Magnesium Deficiency in Obesity Decreases Positive Effects of Vitamin D on Cardiometabolic Risk Indicators.

    Science.gov (United States)

    Stokic, Edita; Romani, Andrea; Ilincic, Branislava; Kupusinac, Aleksandar; Stosic, Zoran; Isenovic, Esma R

    2017-08-21

    Obesity and micronutrient deficiencies contribute to the risk of cardiometabolic diseases such are type 2 diabetes mellitus and cardiovascular disease (CVD). We examined the frequency of concomitant deficit of magnesium (Mg) and vitamin D in obese patients and evaluated the connection of these combined deficiencies with indicators of cardiometabolic risk in non-diabetic subjects. Non-diabetic middle aged adults (n = 80; mean age 36 ± 4 years, 52% women) were recruited based on weight/adiposity parameters [i.e. body mass index (BMI) and body fat percentage (FAT%)]. Cardiometabolic risk indicators [insulin resistance (Homeostatic Model Assessment for insulin resistance (HOMA-IR)) and CVD risk (Framingham risk score for predicting 10-year CVD)], Mg status [i.e. total serum Mg concentration (TMg), chronic latent Mg deficiency (CLMD) - 0.75-0.85 mmol/L], vitamin D status [i.e. serum concentration of 25-hydroxyvitamin D (25(OH)D), vitamin D deficiency <50 nmol/l] were assessed. Among obese subjects 36% presented a combination of vitamin D deficiency and CLMD. In all studied patients, 25(OH)D and TMg levels both, individually and combined, showed a negative linear correlation with HOMA-IR and CVD risk. In subjects with CLMD (TMg ˂0.85 mmol/L), a negative linear coefficient was found between 25(OH)D and, HOMA-IR and CVD risk, compared with subjects with normal TMg status (TMg ≥0.85 mmol/L). CLMD and vitamin D deficiency may commonly be present in obese non-diabetic subjects. Individually and combined, both deficiencies predispose non-diabetic patients to increased risk of cardiometabolic diseases. Maintaining normal Mg status may improve the beneficial effects of vitamin D on cardiometabolic risk indicators. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Quality indicators for acute myocardial infarction: A position paper of the Acute Cardiovascular Care Association.

    Science.gov (United States)

    Schiele, Francois; Gale, Chris P; Bonnefoy, Eric; Capuano, Frederic; Claeys, Marc J; Danchin, Nicolas; Fox, Keith Aa; Huber, Kurt; Iakobishvili, Zaza; Lettino, Maddalena; Quinn, Tom; Rubini Gimenez, Maria; Bøtker, Hans E; Swahn, Eva; Timmis, Adam; Tubaro, Marco; Vrints, Christiaan; Walker, David; Zahger, Doron; Zeymer, Uwe; Bueno, Hector

    2017-02-01

    Evaluation of quality of care is an integral part of modern healthcare, and has become an indispensable tool for health authorities, the public, the press and patients. However, measuring quality of care is difficult, because it is a multifactorial and multidimensional concept that cannot be estimated solely on the basis of patients' clinical outcomes. Thus, measuring the process of care through quality indicators (QIs) has become a widely used practice in this context. Other professional societies have published QIs for the evaluation of quality of care in the context of acute myocardial infarction (AMI), but no such indicators exist in Europe. In this context, the European Society of Cardiology (ESC) Acute Cardiovascular Care Association (ACCA) has reflected on the measurement of quality of care in the context of AMI (ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI)) and created a set of QIs, with a view to developing programmes to improve quality of care for the management of AMI across Europe. We present here the list of QIs defined by the ACCA, with explanations of the methodology used, scientific justification and reasons for the choice for each measure.

  7. Is Radiation Indicated in Patients With Ductal Carcinoma In Situ and Close or Positive Mastectomy Margins?

    International Nuclear Information System (INIS)

    Chan, Linda W.; Rabban, Joseph; Hwang, E. Shelley; Bevan, Alison; Alvarado, Michael; Ewing, Cheryl; Esserman, Laura; Fowble, Barbara

    2011-01-01

    Purpose: Resection margin status is one of the most significant factors for local recurrence in patients with ductal carcinoma in situ (DCIS) treated with breast-conserving surgery with or without radiation. However, its impact on chest wall recurrence in patients treated with mastectomy is unknown. The purpose of this study was to determine chest wall recurrence rates in women with DCIS and close ( 5 cm or diffuse disease. Median width of the close final margin was 2 mm. Nineteen patients had margins of <1 mm. One of these 59 patients experienced a chest wall recurrence with regional adenopathy, followed by distant metastases 2 years following skin-sparing mastectomy. The DCIS was high-grade, 4 cm, with a 5-mm deep margin. A second patient developed an invasive cancer in the chest wall 20 years after her mastectomy for DCIS. This cancer was considered a new primary site arising in residual breast tissue. Conclusions: The risk of chest wall recurrence in this series of patients is 1.7% for all patients and 3.3% for high-grade DCIS. One out of 20 (5%) patients undergoing skin sparing or total skin-sparing mastectomy experienced a chest wall recurrence. This risk of a chest wall recurrence appears sufficiently low not to warrant a recommendation for postmastectomy radiation therapy for patients with margins of <5 mm. There were too few patients with positive margins to draw any firm conclusions.

  8. Indications of 99mTc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties

    International Nuclear Information System (INIS)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M.; Rosset, P.

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a 99 Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  9. Low expression of a few genes indicates good prognosis in estrogen receptor positive breast cancer

    Directory of Open Access Journals (Sweden)

    Buechler Steven

    2009-07-01

    Full Text Available Abstract Background Many breast cancer patients remain free of distant metastasis even without adjuvant chemotherapy. While standard histopathological tests fail to identify these good prognosis patients with adequate precision, analyses of gene expression patterns in primary tumors have resulted in more successful diagnostic tests. These tests use continuous measurements of the mRNA concentrations of numerous genes to determine a risk of metastasis in lymph node negative breast cancer patients with other clinical traits. Methods A survival model is constructed from genes that are both connected with relapse and have expression patterns that define distinct subtypes, suggestive of different cellular states. This in silico study uses publicly available microarray databases generated with Affymetrix GeneChip technology. The genes in our model, as represented by array probes, have distinctive distributions in a patient cohort, consisting of a large normal component of low expression values; and a long right tail of high expression values. The cutoff between low and high expression of a probe is determined from the distribution using the theory of mixture models. The good prognosis group in our model consists of the samples in the low expression component of multiple genes. Results Here, we define a novel test for risk of metastasis in estrogen receptor positive (ER+ breast cancer patients, using four probes that determine distinct subtypes. The good prognosis group in this test, denoted AP4-, consists of the samples with low expression of each of the four probes. Two probes target MKI67, antigen identified by monoclonal antibody Ki-67, one targets CDC6, cell division cycle 6 homolog (S. cerevisiae, and a fourth targets SPAG5, sperm associated antigen 5. The long-term metastasis-free survival probability for samples in AP4- is sufficiently high to render chemotherapy of questionable benefit. Conclusion A breast cancer subtype defined by low

  10. Accurate identification of ALK positive lung carcinoma patients: novel FDA-cleared automated fluorescence in situ hybridization scanning system and ultrasensitive immunohistochemistry.

    Directory of Open Access Journals (Sweden)

    Esther Conde

    Full Text Available BACKGROUND: Based on the excellent results of the clinical trials with ALK-inhibitors, the importance of accurately identifying ALK positive lung cancer has never been greater. However, there are increasing number of recent publications addressing discordances between FISH and IHC. The controversy is further fuelled by the different regulatory approvals. This situation prompted us to investigate two ALK IHC antibodies (using a novel ultrasensitive detection-amplification kit and an automated ALK FISH scanning system (FDA-cleared in a series of non-small cell lung cancer tumor samples. METHODS: Forty-seven ALK FISH-positive and 56 ALK FISH-negative NSCLC samples were studied. All specimens were screened for ALK expression by two IHC antibodies (clone 5A4 from Novocastra and clone D5F3 from Ventana and for ALK rearrangement by FISH (Vysis ALK FISH break-apart kit, which was automatically captured and scored by using Bioview's automated scanning system. RESULTS: All positive cases with the IHC antibodies were FISH-positive. There was only one IHC-negative case with both antibodies which showed a FISH-positive result. The overall sensitivity and specificity of the IHC in comparison with FISH were 98% and 100%, respectively. CONCLUSIONS: The specificity of these ultrasensitive IHC assays may obviate the need for FISH confirmation in positive IHC cases. However, the likelihood of false negative IHC results strengthens the case for FISH testing, at least in some situations.

  11. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality

    Directory of Open Access Journals (Sweden)

    Hickethier T

    2018-05-01

    Full Text Available Tilman Hickethier,1,* Kamal Mammadov,1,* Bettina Baeßler,1 Thorsten Lichtenstein,1 Jochen Hinkelbein,2 Lucy Smith,3 Patrick Sven Plum,4 Seung-Hun Chon,4 David Maintz,1 De-Hua Chang1 1Department of Radiology, University Hospital of Cologne, Cologne, Germany; 2Department of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, Germany; 3Faculty of Medicine, Memorial University of Newfoundland, St. John’s, Canada; 4Department of General, Visceral and Cancer Surgery, University Hospital of Cologne, Cologne, Germany *These authors contributed equally to this work Background: The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs for trauma patients using conventional or optimized patient positioning. Patients and methods: Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning. Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Results: Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%, liver (40 vs 8% and spleen (27 vs 5% occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. Conclusion: An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality. Keywords: CT scan, polytrauma, acute care, time requirement, positioning

  12. Optimization of transmission-scan time for the FixER method: a MR-based PET attenuation correction with a weak fixed-position external radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Kershaw, Jeff; Yoshida, Eiji [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Shiraishi, Takahiro [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Suga, Mikio [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Center for Frontier Medical Engineering, Chiba University (Japan); Obata, Takayuki [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Ito, Hiroshi; Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan)

    2014-07-29

    In recent work, we proposed an MRI-based attenuation-coefficient (μ-value) estimation method that uses a weak fixed-position external radiation source to construct an attenuation map for PET/MRI. In this presentation we refer to this method as FixER, and perform a series of simulations to investigate the duration of the transmission scan required to accurately estimate μ-values.

  13. Optimization of transmission-scan time for the FixER method: a MR-based PET attenuation correction with a weak fixed-position external radiation source

    International Nuclear Information System (INIS)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Kershaw, Jeff; Yoshida, Eiji; Shiraishi, Takahiro; Suga, Mikio; Obata, Takayuki; Ito, Hiroshi; Yamaya, Taiga

    2014-01-01

    In recent work, we proposed an MRI-based attenuation-coefficient (μ-value) estimation method that uses a weak fixed-position external radiation source to construct an attenuation map for PET/MRI. In this presentation we refer to this method as FixER, and perform a series of simulations to investigate the duration of the transmission scan required to accurately estimate μ-values.

  14. Pulmonary suture abscess with false-positive 18F-fluorodeoxyglucose positron emission scan mimicking lung cancer recurrence.

    Science.gov (United States)

    Iwasaki, Teruo; Nakagawa, Katsuhiro; Katsura, Hiroshi; Nakane, Shigeru; Kawahara, Kunimitsu; Fukuda, Haruyuki

    2006-08-01

    We present the case of a 57-year-old woman with pulmonary suture abscess. She had undergone right S3 segmentectomy for early lung adenocarcinoma 7 years before and right breast-conserving surgery for invasive ductal carcinoma 5 months previously, followed by irradiation plus endocrine therapy. Chest radiography and computed tomography revealed an irregular mass (3.5 cm in diameter) between the residual S1 segment and the middle lobe, neighboring the staple line of the segmentectomy. 18F-fluorodeoxyglucose uptake into the mass increased, seen by positron emission scans. Therefore, we could not rule out the possibility of local recurrence of lung cancer and resected it. Pathologically and microbiologically, the mass was a suture abscess arising around the nylon suture of the previous segmentectomy. This lesion was the result of a foreign-body reaction, as confirmed by polarized microscopy. Moreover, titanium staples at the segmentectomy and breast-conserving surgery may also have contributed to this condition.

  15. Patient-provider relationship predicts mental and physical health indicators for HIV-positive men who have sex with men.

    Science.gov (United States)

    Bankoff, Sarah M; McCullough, Mary B; Pantalone, David W

    2013-06-01

    We used secondary data analysis to examine associations among aspects of patient-provider relationships and mental and physical health indicators. Positive patient perceptions of patient-provider relationships were associated with fewer mental health symptoms in this outpatient sample of HIV-positive men who have sex with men (N = 171). Regression analyses revealed the role of anxiety and depression in explaining associations between two aspects of patient-provider relationships (i.e. quality of information offered and provider interactional style) and health-related quality of life. The findings demonstrated the importance of patient-provider relationships to improving physical health and functioning and maintaining engagement in care, among HIV-positive men who have sex with men.

  16. Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn

    NARCIS (Netherlands)

    Beek, F.B. van der; Briaire, J.J.; Marel, K.S. van der; Verbist, B.M.; Frijns, J.H.

    2016-01-01

    OBJECTIVES: In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. DESIGN: A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and

  17. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  18. Scientific journals in the SciELO database, indicators of impact and the relative position of Ambiente & Água

    Directory of Open Access Journals (Sweden)

    Nelson Wellausen Dias

    2010-12-01

    Full Text Available This editorial describes the process of periodic evaluation by CAPES, based on commercial indices proposed by companies such as the ISI FI by Thomson Reuters and SCImago by Scopus and public indices as proposed by SciELO and other freely calculated indices based on Google Scholar and investigates the impact position of the journal Ambiente & Agua compared with journals from the SciELO base. Results show that Ambiente & Agua is in the right path in the search for quality. Its editorial board strongly recommends that Brazilian public scientific agencies consider tools that are cost free and have large coverage for impact evaluation to allow the impact assessment of a range of emerging journals in a common and wide basis for all scientific journals.

  19. A generalized mean-squared displacement from inelastic fixed window scans of incoherent neutron scattering as a model-free indicator of anomalous diffusion confinement

    International Nuclear Information System (INIS)

    Roosen-Runge, F.; Seydel, T.

    2015-01-01

    Elastic fixed window scans of incoherent neutron scattering are an established and frequently employed method to study dynamical changes, usually over a broad temperature range or during a process such as a conformational change in the sample. In particular, the apparent mean-squared displacement can be extracted via a model-free analysis based on a solid physical interpretation as an effective amplitude of molecular motions. Here, we provide a new account of elastic and inelastic fixed window scans, defining a generalized mean-squared displacement for all fixed energy transfers. We show that this generalized mean-squared displacement in principle contains all information on the real mean-square displacement accessible in the instrumental time window. The derived formula provides a clear understanding of the effects of instrumental resolution on the apparent mean-squared displacement. Finally, we show that the generalized mean-square displacement can be used as a model-free indicator on confinement effects within the instrumental time window. (authors)

  20. Radio-isotope scanning using labelled bleomycin in positive and differential diagnosis of primary and secondary malignant pulmonary lesions

    International Nuclear Information System (INIS)

    Robert, J.; Bertrand, A.; Nouel, J.P.; Witz, H.

    1975-01-01

    A lung scan using bleomycin labelled with cobalt 57 was carried out in 308 patients representing 191 primary malignant tumours, 48 pulmonary metastases and 69 benign lesions. The primary and secondary malignant lesions always gave rise to a hyperactive focus except in 8 cases of primary lung tumour. The negative examination may be explained, either by the small size of the lesion or by radiotherapy in progress. Among the benign lesions, only advanced tuberculosis and very inflammatory lung diseases frequently took up labelled bleomycin (15 hyperactive foci out of 69 benign lesions). Quantitative measurements, i.e. ratio of the lesional activity/activity of healthy lung tissue, were carried out in all patients. The malignant lesions were usually more active than the benign lesions. There was no definite correlation between the uptake of labelled bleomycin and the histological nature of the lesion. However, undifferentiated and anaplastic carcinomas were often more active. One should emphasize that these results show that a hyperactive focus has a 94% chance of being a carcinoma. The absence of bleomycin uptake means that there is a 92% chance of a benign lesion [fr

  1. Computed tomography scan in supine and prone positions: an alternative method to detect intramural gas in emphysematous cystitis and to evaluate efficacy after adjuvant continuous intravesical irrigation treatment.

    Science.gov (United States)

    Cortés-González, Jeff R; Ortiz-Lara, Gerardo E; Salinas, Matías; Hernández-Galván, Fernando; Gómez-Guerra, Lauro S

    2013-04-01

    To evaluate the efficacy of continuous intravesical irrigation with saline plus amikacin as adjuvant therapy and to evaluate the computed tomography (CT) scan in supine and prone positions (CystoCT scan) as an alternative diagnostic and evaluation method of intramural gas in emphysematous cystitis (EC) before and after treatment. Consecutive patients with a diagnosis of EC who were hospitalized between March 2006 and January 2011 were investigated. The diagnosis was made by CystoCT scan. Treatment consisted of intravenous antibiotics, control of concomitant diseases, and placement of a 3-way urinary catheter for continuous irrigation of 500 mg of amikacin diluted in 1 l of saline given on days 0, 3, and 7. Treatment was considered successful when there was an absence of gas in the bladder wall, the urine culture was negative, there was clinical improvement, and there was an absence of toxicity. Eleven patients were hospitalized with a diagnosis of EC during the study period. Four were excluded from the study, 2 due to the lack of confirmation of the diagnosis with the CystoCT scan. Treatment was successful in all patients; for 6 (86%) this was achieved in 3 days and for 1 (14%) in 7 days. No toxicity was reported. Continuous intravesical irrigation with saline plus amikacin as adjuvant treatment of EC is an inexpensive, effective, and safe tool that might help conventional treatment and provide a rapid recovery. The CystoCT scan is an alternative method to diagnose and evaluate intramural gas in EC patients. These findings should be challenged in a randomized, multi-centre, placebo-controlled clinical trial.

  2. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Juan; Beltran, Chris J., E-mail: beltran.chris@mayo.edu; Herman, Michael G. [Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2014-08-15

    Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 to 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot

  3. Comparison of reliability of five patellar position indices at various stifle joint angles in pelvic limbs obtained from cadavers of red foxes (Vulpes vulpes)

    DEFF Research Database (Denmark)

    Miles, James E; Nielsen, Dorte H; Jensen, Bente Rona

    2012-01-01

    To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use.......To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use....

  4. Clinical Usefulness of F-18 FDG PET/CT in papillary thyroid cancer with negative radioiodine scan and elevated thyroglobulin level or positive anti-thyroglobulin antibody

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Su Jung; Jung, Kyung Pyo; Lee, Sun Seong; Park, Yun Soo; Lee, Seok Mo [Dept. of Nuclear Medicine, Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of); Bae, Sang Kyun [Dept. of Nuclear Medicine, Haeundae Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of)

    2016-06-15

    Elevated thyroglobulin (Tg) levels, along with a negative radioiodine scan, present a clinical problem for the diagnosis of recurrence in papillary thyroid cancer (PTC) patients. The purpose of this study was to assess (1) the usefulness of 18F-fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET)/computed tomography (CT) for PTC patients with negative diagnostic radioiodine scan and elevated serum Tg level or positive anti-thyroglobulin antibody (TgAb), and (2) the effect of endogenous thyroid stimulating hormone (TSH) stimulation (ETS) on detecting recurrence in these circumstances. Eighty-four patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb under ETS were included. Correlation with clinicopathological features and recurrence, detectability of FDG PET/CT and cut-off value of serum Tg for recurrence in PTC patients with these circumstance were assessed. In addition, detectability of F-18 FDG PET/CT under ETS and suppression were compared. In Cox regression analysis, only serum Tg level was significantly associated with recurrence (P<0.001, HR  = 1.13; 95 % CI, 1.061–1.208). The cut-off level of Tg was 21.5 ng/mL (AUC, 0.919; P < 0.001) for discriminating the recurrence in the patients with positive PET/CT finding. The sensitivity, specificity, PPV, NPV, and accuracy of F-18 FDG PET/CT for detecting recurrence were 64 %, 94 %, 86 %, 81 %, and 83 %. In the analysis of F-18 FDG PET/CT under ETS, the sensitivity, specificity, PPV, NPV and accuracy was 64 %, 94 %, 88 %, 81 % and 83 %. Those under TSH suppression were 67 %, 92 %, 80 %, 85 % and 83 %. F-18 FDG PET/CT, although less sensitive, showed high specificity, PPV, NPV, and accuracy and therefore can be useful for the patients with negative diagnostic radioiodine scan and elevated serum Tg or positive TgAb. In addition, FDG PET/CT under ETS does not seem to have an additive role in detecting recurrence in these patients.

  5. Detecting loci under recent positive selection in dairy and beef cattle by combining different genome-wide scan methods.

    Directory of Open Access Journals (Sweden)

    Yuri Tani Utsunomiya

    Full Text Available As the methodologies available for the detection of positive selection from genomic data vary in terms of assumptions and execution, weak correlations are expected among them. However, if there is any given signal that is consistently supported across different methodologies, it is strong evidence that the locus has been under past selection. In this paper, a straightforward frequentist approach based on the Stouffer Method to combine P-values across different tests for evidence of recent positive selection in common variations, as well as strategies for extracting biological information from the detected signals, were described and applied to high density single nucleotide polymorphism (SNP data generated from dairy and beef cattle (taurine and indicine. The ancestral Bovinae allele state of over 440,000 SNP is also reported. Using this combination of methods, highly significant (P<3.17×10(-7 population-specific sweeps pointing out to candidate genes and pathways that may be involved in beef and dairy production were identified. The most significant signal was found in the Cornichon homolog 3 gene (CNIH3 in Brown Swiss (P = 3.82×10(-12, and may be involved in the regulation of pre-ovulatory luteinizing hormone surge. Other putative pathways under selection are the glucolysis/gluconeogenesis, transcription machinery and chemokine/cytokine activity in Angus; calpain-calpastatin system and ribosome biogenesis in Brown Swiss; and gangliosides deposition in milk fat globules in Gyr. The composite method, combined with the strategies applied to retrieve functional information, may be a useful tool for surveying genome-wide selective sweeps and providing insights in to the source of selection.

  6. Forward Model Studies of Water Vapor Using Scanning Microwave Radiometers, Global Positioning System, and Radiosondes during the Cloudiness Intercomparison Experiment

    International Nuclear Information System (INIS)

    Mattioli, Vinia; Westwater, Ed R.; Gutman, S.; Morris, Victor R.

    2005-01-01

    Brightness temperatures computed from five absorption models and radiosonde observations were analyzed by comparing them with measurements from three microwave radiometers at 23.8 and 31.4 GHz. Data were obtained during the Cloudiness Inter-Comparison experiment at the U.S. Department of Energy's Atmospheric Radiation Measurement Program's (ARM) site in North-Central Oklahoma in 2003. The radiometers were calibrated using two procedures, the so-called instantaneous ?tipcal? method and an automatic self-calibration algorithm. Measurements from the radiometers were in agreement, with less than a 0.4-K difference during clear skies, when the instantaneous method was applied. Brightness temperatures from the radiometer and the radiosonde showed an agreement of less than 0.55 K when the most recent absorption models were considered. Precipitable water vapor (PWV) computed from the radiometers were also compared to the PWV derived from a Global Positioning System station that operates at the ARM site. The instruments agree to within 0.1 cm in PWV retrieval

  7. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  8. Overweight and weight dissatisfaction related to socio-economic position, integration and dietary indicators among south Asian immigrants in Oslo.

    Science.gov (United States)

    Råberg, Marte; Kumar, Bernadette; Holmboe-Ottesen, Gerd; Wandel, Margareta

    2010-05-01

    To investigate how socio-economic position, demographic factors, degree of integration and dietary indicators are related to BMI/waist:hip ratio (WHR) and to weight dissatisfaction and slimming among South Asians in Oslo, Norway. Cross-sectional study consisting of a health check including anthropometric measures and two self-administered questionnaires. Oslo, Norway. Pakistanis and Sri Lankans (n 629), aged 30-60 years, residing in Oslo. BMI was positively associated with female gender (P = 0.004) and Pakistani origin (P integration (measured by a composite index, independent of duration of residence; P = 0.017). One-third of those with normal weight and most of those obese were dissatisfied with their weight. Among these, about 40 % had attempted to slim during the past year. Dissatisfaction with weight was positively associated with education in women (P = 0.006) and with integration in men (P = 0.026), and inversely associated with physical activity (P = 0.044) in men. Women who had made slimming attempts had breakfast and other meals less frequently than others (P < 0.05). Weight dissatisfaction exists among South Asian immigrants. More research is needed regarding bodily dissatisfaction and the relationship between perception of weight and weight-change attempts among immigrants in Norway, in order to prevent and treat both obesity and eating disorders.

  9. Clinical indications to the use of (99m)Tc-EDDA/HYNIC-TOC to detect somatostatin receptor-positive neuroendocrine tumors.

    Science.gov (United States)

    Parisella, M G; Chianelli, M; D'Alessandria, C; Todino, V; Mikolajczak, R; Papini, E; Dierckx, R A; Scopinaro, F; Signore, A

    2012-02-01

    The aim of this study was to define, retrospectively, the utility to perform (99m)Tc-EDDA/HYNIC-Tyr3-octreotide ((99m)Tc-EDDA/HYNIC-TOC) scan in patients with NET. We studied 50 consecutive patients affected by different types of NET and divided in two groups. Group 1: 34 patients with known lesions in which (99m)Tc-EDDA/HYNIC-TOC was performed for staging, characterisation or to choose the appropriate treatment. Group 2: 16 patients suspected of having NET or in follow up after surgery. Patients were injected with 370 MBq of (99m)Tc-EDDA/HYNIC-Tyr3-octreotide and whole-body and SPET images acquired 2-3 hours after injection. Overall, 29 patients (58%) had a positive scan, with a sensitivity, specificity and accuracy of 70.3%, 76.9% and 72%, respectively (78.1%, 50% and 76.5%, in group 1 and 20%, 81.2%, 62.5% in group 2). In patients from group 1 (99m)Tc-HYNIC-TOC scintigraphy showed a concordance of 68% with another imaging procedure and in 9 patients revealed a greater number of lesions. In the second group, false negative results were especially found in patients with medullary thyroid cancer with negative radiological findings and elevated calcitonin. In conclusion, (99m)Tc-EDDA/HYNIC-TOC is highly indicated for in vivo histological characterization of known NET lesions, previously identified by other imaging modalities or biopsy, to plan appropriate therapy especially for patients with inoperable disease. In patients with only biochemical suspicion of NET and in those with negative markers, this scintigraphy does not significantly modify the clinical management.

  10. OctreoScan 111 for imaging of a somatostatin receptor-positive islet cell tumor in rat

    International Nuclear Information System (INIS)

    Bruns, C.; Stolz, B.; Albert, R.; Marbach, P.; Pless, J.

    1993-01-01

    We report here the in vitro characterization of SDZ 215-811 and the in vivo imaging of a islet cell tumor gown in rats using [ 111 In]SDZ 215-811. In vitro autoradiographies revelaed a high density of SRIF receptors on the pancreatic tumor tissue. As early as 5 min after intravenous injection of [ 111 In]SDZ 215-811 into tumour-bearing rats, the tumors were clearly localized by gamma-camera scintigraphy. Even 24 h post injection, the islet cell tumor was still detectable. The radioligand was mainly cleared from the circulation via the Kidneys, with a rapid α-phase (t 1/2 =5.6 min) and a slow elimination phase (t 1/2 =7.3 h). Biodistribution studies revealed a relatively high accumulation of radioactivity in the kidneys, but low uptake into the liver and the intestine. High uptake of [ 111 In]SDZ 215-811 was observed for the tumor tissue (0.92±0.07% ID/g; 1 h post injection). Interestingly, a tumor load of 0.14±0.01% ID/g was still measured after 24 h. The tumor/blood ratio was 4.93 after 24 h, indicating specific accumulation of radioactivity in the islet cell tumour. [ 111 In]SDZ 215-811 appears to be sensitive and specific ligand for SRIF receptorpositive tumors and offers an easy procedure for scintigraphic imaging of such tumors in man. (orig.)

  11. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Levin, W.J.; Shary, J.H. III; Nichols, L.T.; Lucente, F.E.

    1986-01-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  12. The Utility and indication of FDG-PET scan in patients with cervical cancer: experience in patients with no evidence of recurrence with conventional radiologic examination and tumor markers

    International Nuclear Information System (INIS)

    Kim, Jong Hoon

    2000-12-01

    The purpose of this study was to investigate the clinical feasibility of FDG-PET(Positron Emission Tomography) scan in patients with clinically no evidence of disease after treatment of cervical cancer. One hundred and one patients with clinically NED(no evidence of disease) state after treatment of cervical cancer underwent PET scan. FDG-PET scan was obtained with a GE Advance Scanner, beginning at 50 minutes after injection of 370-555 MBq(10-15 mCi) of 18F FDG. Regional scan was also obtained with emission image. Uptake exceeding 3.0 SUV was determined as a positive finding. Recurrence was confirmed by CT, MRI, and needle biopsy if possible. Among 101 patients showing no evidence of disease, 17 patients(16.8%) showed abnormal PET scan findings. Clinically, 8 patients(7.9%) were confirmed to have recurrent lesion by CT, MRI or by needle biopsy. PET scan could detect recurrent lesions in the mediastinum or lung(10/17), pelvis(7/17), and supraclavicular lymph node(2/17). The sensitivity and specificity of PET scan in patients with cervical cancer showing no evidence of disease were 100% and 90.3%, respectively. The positive predictive value, negative predictive value and false positive rate were 47.1%, 100% and 52.9%. PET scan could detect 7.9% of early recurrence in patients with cervical cancer with NED status. FDG-PET scan may be a useful method in detecting metastases or recurrence of a cervical cancer showing no evidence of disease by routine conventional imaging studies

  13. Positive autoantibodies to ZnT8 indicate elevated risk for additional autoimmune conditions in patients with Addison's disease.

    Science.gov (United States)

    Fichna, Marta; Rogowicz-Frontczak, Anita; Żurawek, Magdalena; Fichna, Piotr; Gryczyńska, Maria; Zozulińska-Ziółkiewicz, Dorota; Ruchała, Marek

    2016-07-01

    Autoimmune Addison's disease (AAD) associates with exceptional susceptibility to develop other autoimmune conditions, including type 1 diabetes (T1D), marked by positive serum autoantibodies to insulin (IAA), glutamic acid decarboxylase (GADA) and insulinoma-associated protein 2 (IA-2A). Zinc transporter 8 (ZnT8) is a new T1D autoantigen, encoded by the SLC30A8 gene. Its polymorphic variant rs13266634C/T seems associated with the occurrence of serum ZnT8 antibodies (ZnT8A). This study was designed to determine the prevalence of serum ZnT8A and their clinical implication in 140 AAD patients. Other beta cell and thyroid-specific autoantibodies were also investigated, and ZnT8A results were confronted with the rs13266634 genotype. ZnT8A were detectable in 8.5 %, GADA in 20.7 %, IA-2A in 5.7 %, IAA in 1.6 % and various anti-thyroid antibodies in 7.1-67.8 % individuals. Type 1 diabetes was found in 10 % AAD patients. ZnT8A were positive in 57.1 % of T1D patients and 3.4 % non-diabetic AAD. Analysis of ZnT8A enabled to identify autoimmunity in two (14.3 %) T1D individuals previously classified as autoantibody-negative. ZnT8A-positive patients revealed significantly higher number of autoimmune conditions (p < 0.001), increased prevalence of T1D (p < 0.001) and other beta cell-specific autoantibodies. Carriers of the rs13266634 T-allele displayed increased frequency (p = 0.006) and higher titres of ZnT8A (p = 0.002). Our study demonstrates high incidence of ZnT8A in AAD patients. ZnT8A are associated with coexisting T1D and predictive of T1D in non-diabetic subjects. Moreover, positive ZnT8A in AAD indicate elevated risk for additional autoimmune conditions. Autoantibodies to beta cell antigens, comprising ZnT8, could be included in routine screening panels in AAD.

  14. SU-E-J-220: Assessment of MRI Geometric Distortion in Head and Neck Cancer Patients Scanned in Immobilized Radiation Treatment Position

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C; Mohamed, A; Weygand, J; Ding, Y; Fuller, C; Frank, S; Wang, J [MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Uncertainties about geometric distortion have somewhat hindered MRI simulation in radiation therapy. Most of the geometric distortion studies were performed with phantom measurements but another major aspect of MR distortion is patient related. We studied the geometric distortion in patient images by comparing their MRI scans with the corresponding CT, using CT as the non-distorted gold standard. Methods: Ten H&N cancer patients were imaged with MRI as part of a prospective IRB approved study. All patients had their treatment planning CT done on the same day or within one week of the MRI. MR Images were acquired with a T2 SE sequence (1×1×2.5mm voxel size) in the same immobilization position as in the CT scans. MRI to CT rigid registration was then done and geometric distortion comparison was done by measuring the corresponding anatomical landmarks on both the MRI and the CT images by two observers. Several skin to skin (9 landmarks), bone to bone (8 landmarks), and soft tissue (3 landmarks) were measured at specific levels in horizontal and vertical planes of both scans. Results: The mean distortion for all landmark measurements in all scans was 1.8±1.9mm. For each patient 11 measurements were done in the horizontal plane while 9 were done in the vertical plane. The measured geometric distortion were significantly lower in the horizontal axis compared to the vertical axis (1.3±0.16 mm vs 2.2±0.19 mm, respectively, P=0.003*). The magnitude of distortion was lower in the bone to bone landmarks compared to the combined soft tissue and skin to skin landmarks (1.2±0.19 mm vs 2.3±0.17 mm, P=0.0006*). The mean distortion measured by observer one was not significantly different compared toobserver 2 (2.3 vs 2.4 mm, P=0.4). Conclusion: MRI geometric distortions were quantified in H&N patients with mean error of less than 2 mm. JW received a corporate sponsored research grant from Elekta.

  15. SOCS3 promoter hypermethylation is a favorable prognosticator and a novel indicator for G-CIMP-positive GBM patients.

    Science.gov (United States)

    Feng, Ying; Wang, Zheng; Bao, Zhaoshi; Yan, Wei; You, Gan; Wang, Yinyan; Hu, Huimin; Zhang, Wei; Zhang, Quangeng; Jiang, Tao

    2014-01-01

    Hypermethylation of the suppressor of cytokine signaling 3(SOCS3) promoter has been reported to predict a poor prognosis in several cancers including glioblastoma multiforme (GBM). We explored the function of SOCS3 promoter hypermethylation in GBM cohorts, including analysis of the CpG island methylator phenotype (CIMP), when a large number of gene loci are simultaneously hypermethylated. A whole genome promoter methylation profile was performed in a cohort of 33 GBM samples, with 13 long-term survivors (LTS; overall survival ≥ 18 months) and 20 short-term survivors (STS; overall survival ≤ 9 months). The SOCS3 promoter methylation status was compared between the two groups. In addition, we investigated the relationship of SOCS3 promoter methylation and G-CIMP status. Interestingly, in our present study, we found that SOCS3 promoter methylation was statistically significantly higher in the 13 LTS than that in the 20 STS. Furthermore, high SOCS3 promoter methylation detected via pyro-sequencing predicted a better prognosis in an independent cohort containing 62 GBM patients. This correlation was validated by the dataset from the Cancer Genome Atlas(TCGA) and the Chinese Cancer Genome Atlas(CGGA). In addition, we found that hypermethylation of the SOCS3 promoter was tightly associated with the G-CIMP-positive GBM patients. Using a total of 359 clinical samples, we demonstrate that SOCS3 promoter hypermethylation status has a favorable prognostic value in GBM patients because of whole genome methylation status. Particularly, the hypermethylation of the SOCS3 promoter indicates positive G-CIMP status.

  16. Endocrine Society of Australia position statement on male hypogonadism (part 1): assessment and indications for testosterone therapy.

    Science.gov (United States)

    Yeap, Bu B; Grossmann, Mathis; McLachlan, Robert I; Handelsman, David J; Wittert, Gary A; Conway, Ann J; Stuckey, Bronwyn Ga; Lording, Douglas W; Allan, Carolyn A; Zajac, Jeffrey D; Burger, Henry G

    2016-08-15

    This article, Part 1 of the Endocrine Society of Australia's position statement on male hypogonadism, focuses on assessment of male hypogonadism, including the indications for testosterone therapy. (Part 2 will deal with treatment and therapeutic considerations.) Key points and recommendations are:Pathological hypogonadism arises due to diseases of the hypothalamus or pituitary gland (hypogonadotropic hypogonadism) or testes (hypergonadotropic hypogonadism). It is a clinical diagnosis with a pathological basis, confirmed by hormone assays.Hormonal assessment is based on measurement of circulating testosterone, luteinising hormone (LH) and follicle-stimulating hormone (FSH) concentrations. Measurement of sex hormone-binding globulin levels can be informative, but use of calculated free testosterone is not recommended for clinical decision making.Testosterone replacement therapy is warranted in men with pathological hypogonadism, regardless of age.Currently, there are limited data from high-quality randomised controlled trials with clinically meaningful outcomes to justify testosterone treatment in older men, usually with chronic disease, who have low circulating testosterone levels but without hypothalamic, pituitary or testicular disease.Obesity, metabolic syndrome and type 2 diabetes are associated with lowering of circulating testosterone level, but without elevation of LH and FSH levels. Whether these are non-specific consequences of non-reproductive disorders or a correctable deficiency state is unknown, but clear evidence for efficacy and safety of testosterone therapy in this setting is lacking.Glucocorticoid and opioid use is associated with possibly reversible reductions in circulating testosterone level, without elevation of LH and FSH levels. Where continuation of glucocorticoid or opioid therapy is necessary, review by an endocrinologist may be warranted.Changes in management as result of the position statement: Men with pathological hypogonadism should

  17. SOCS3 promoter hypermethylation is a favorable prognosticator and a novel indicator for G-CIMP-positive GBM patients.

    Directory of Open Access Journals (Sweden)

    Ying Feng

    Full Text Available Hypermethylation of the suppressor of cytokine signaling 3(SOCS3 promoter has been reported to predict a poor prognosis in several cancers including glioblastoma multiforme (GBM. We explored the function of SOCS3 promoter hypermethylation in GBM cohorts, including analysis of the CpG island methylator phenotype (CIMP, when a large number of gene loci are simultaneously hypermethylated.A whole genome promoter methylation profile was performed in a cohort of 33 GBM samples, with 13 long-term survivors (LTS; overall survival ≥ 18 months and 20 short-term survivors (STS; overall survival ≤ 9 months. The SOCS3 promoter methylation status was compared between the two groups. In addition, we investigated the relationship of SOCS3 promoter methylation and G-CIMP status.Interestingly, in our present study, we found that SOCS3 promoter methylation was statistically significantly higher in the 13 LTS than that in the 20 STS. Furthermore, high SOCS3 promoter methylation detected via pyro-sequencing predicted a better prognosis in an independent cohort containing 62 GBM patients. This correlation was validated by the dataset from the Cancer Genome Atlas(TCGA and the Chinese Cancer Genome Atlas(CGGA. In addition, we found that hypermethylation of the SOCS3 promoter was tightly associated with the G-CIMP-positive GBM patients.Using a total of 359 clinical samples, we demonstrate that SOCS3 promoter hypermethylation status has a favorable prognostic value in GBM patients because of whole genome methylation status. Particularly, the hypermethylation of the SOCS3 promoter indicates positive G-CIMP status.

  18. Composition and Structure of Microalgae Indicated in Raman and Hyperspectral Spectra and Scanning Electron Microscopy: from Cyanobacteria to Isolates from Coal-bed Methane Water Ponds

    Science.gov (United States)

    Zhou, X.; Zhou, Z.; Apple, M. E.; Spangler, L.

    2017-12-01

    Microalgae can be used for many potential applications for human's benefits. These potential applications included biofuel production from microalgae, biofiltering to cleaning water, chemical extraction as nutrients, etc. However, exploration for such applications is still in the early stages. For instance, many species and strains of microalgae have been investigated for their lipid content and growing conditions for efficient productions of lipids, but no specific species have yet been chosen as a fuel source for commercial production because of the huge biodiversity and subsequently a wide range of species that can potentially be exploited for biodiesel production, the great variability between species in their fuel precursor producing capabilities. Numerous coal-bed methane water ponds were established in the world as a consequence of coal-bed methane production from deep coal seams. Microalgae were isolated from such ponds and potentially these ponds can be used as venues for algal production. In this study, we characterized chemical composition and structure of the Cyanobacteria Anabaena cylindrica (UTEX # 1611) and isolates from coal-bed methane ponds Nannochloropsis gaditana and PW95 using Laser Raman Spectroscopy (LRS), hyperspectral spectra, and Scanning Electron Microscope (SEM). The objective is to seek bio-indicators for potential applications of these microalgae species. For instance, indicator of rich content lips shows the great potential for biofuel production. Fig.1 shows an example of the Raman spectra of the three species in desiccated form. The spectral peaks were isolated and the corresponding composition was identified. The insert at the right hand of the Raman spectrum of each species is the micrograph of the cell morphology under a microscope. The Raman spectra of cells in aquatic solutions were also obtained and compared with the desiccated form. The hyperspectral reflectances of the three species show quite different characteristics and

  19. Ocular VEMPs indicate repositioning of otoconia to the utricle after successful liberatory maneuvers in benign paroxysmal positioning vertigo

    Science.gov (United States)

    BREMOVA, TATIANA; BAYER, OTMAR; AGRAWAL, YURI; KREMMYDA, OLYMPIA; BRANDT, THOMAS; TEUFEL, JULIAN; STRUPP, MICHAEL

    2014-01-01

    Conclusions This study showed a transient increase of ocular vestibular evoked myogenic potential (oVEMP) amplitudes in the affected ear after successful liberatory maneuvers and no changes in cervical VEMP (cVEMP) amplitudes. These findings support the hypothesis that successful liberatory maneuvers can lead to a repositioning of otoconia to the utricle. Objectives To evaluate whether oVEMP amplitudes increase after successful liberatory maneuvers in patients with posterior semicircular canal benign paroxysmal positioning vertigo (pc-BPPV), while cVEMP amplitudes do not change. These findings may indicate a successful repositioning of dislodged otoconia to the utricular macula, but not to the saccular macula. Methods Thirty patients with unilateral pc-BPPV were prospectively examined with bone-conducted oVEMP and air-conducted cVEMP at four time points: before, after, 1 week after, and 1 month after the liberatory maneuvers (Sémont maneuvers). Results At the 1-week follow-up, 20 of 30 patients were asymptomatic (responders); BPPV could still be induced in the other 10 (non-responders). In responders the mean n10 amplitude on the affected side increased from 12 ± 6.5 μV at baseline (before the treatment) to 15.9 ± 7.1 μV at 1 week after treatment; this increase was significantly (p = 0.001) higher in responders than in non-responders. cVEMP did not differ significantly. PMID:24245699

  20. Sublingual immunotherapy (SLIT – indications, mechanism, and efficacy Position paper prepared by the Section of Immunotherapy, Polish Society of Allergy

    Directory of Open Access Journals (Sweden)

    Marek Jutel

    2015-12-01

    Full Text Available SLIT ( sublingual immunotherapy induces allergen-specific immune tolerance by sublingual administration of a gradually increasing dose of an allergen. The mechanism of SLIT is comparable to those during SCIT (subcutaneous immunotherapy, with the exception of local oral dendritic cells, pre-programmed to elicit tolerance. In the SLIT dose, to achieve the same efficacy as in SCIT, it should be 50–100 times higher with better safety profile. The highest quality evidence supporting the efficacy of SLIT lasting 1 – 3 years has been provided by the large scale double-blind, placebo-controlled (DBPC trials for grass pollen extracts, both in children and adults with allergic rhinitis. Current indications for SLIT are allergic rhinitis (and conjunctivitis in both children and adults sensitized to pollen allergens (trees, grass, Parietaria , house dust mites ( Dermatophagoides pteronyssinus, Dermatophagoides farinae , cat fur, as well as mild to moderate controlled atopic asthma in children sensitized to house dust mites. There are positive findings for both asthma and new sensitization prevention. Severe adverse events, including anaphylaxis, are very rare, and no fatalities have been reported. Local adverse reactions develop in up to 70 – 80% of patients. Risk factors for SLIT adverse events have not been clearly identified. Risk factors of non-adherence to treatment might be dependent on the patient, disease treatment, physician-patient relationship, and variables in the health care system organization.

  1. Liver-lung scan in the diagnosis of right subphrenic abscess

    International Nuclear Information System (INIS)

    Middleton, H.M. III; Patton, D.D.; Hoyumpa, A.M. Jr.; Schenker, S.

    1976-01-01

    To assess the value of liver-lung scanning in the diagnosis of right subphrenic abscess, 148 scans were reviewed against corresponding charts. Of 91 scans with adequate clinical data, overall scanning error was 19.3 percent with 14 false positive and 3 false negative scans. Among 49 scans (of the initial group of 91 studies) with presence or absence of actual pathology proved by surgery and/or autopsy, there were 3 true positive, 12 false positive, 29 true negative, and 3 false negative scans. Analysis of data indicated lower accuracy of scan interpretation than generally reported, low specificity for positive scans and high specificity for negative scans, correlation of false interpretations with atypical degrees of liver-lung separation and with scanning defects in liver and lung, and failure of rereading significantly to improve accuracy of interpretation

  2. An RFID-Based Smart Structure for the Supply Chain: Resilient Scanning Proofs and Ownership Transfer with Positive Secrecy Capacity Channels †

    Science.gov (United States)

    Ortiz, Andrés

    2017-01-01

    The National Strategy for Global Supply Chain Security published in 2012 by the White House identifies two primary goals for strengthening global supply chains: first, to promote the efficient and secure movement of goods, and second to foster a resilient supply chain. The Internet of Things (IoT), and in particular Radio Frequency Identification (RFID) technology, can be used to realize these goals. For product identification, tracking and real-time awareness, RFID tags are attached to goods. As tagged goods move along the supply chain from the suppliers to the manufacturers, and then on to the retailers until eventually they reach the customers, two major security challenges can be identified: (I) to protect the shipment of goods that are controlled by potentially untrusted carriers; and (II) to secure the transfer of ownership at each stage of the chain. For the former, grouping proofs in which the tags of the scanned goods generate a proof of “simulatenous” presence can be employed, while for the latter, ownership transfer protocols (OTP) are used. This paper describes enhanced security solutions for both challenges. We first extend earlier work on grouping proofs and group codes to capture resilient group scanning with untrusted readers; then, we describe a modified version of a recently published OTP based on channels with positive secrecy capacity adapted to be implemented on common RFID systems in the supply chain. The proposed solutions take into account the limitations of low cost tags employed in the supply chain, which are only required to generate pseudorandom numbers and compute one-way hash functions. PMID:28677637

  3. An RFID-Based Smart Structure for the Supply Chain: Resilient Scanning Proofs and Ownership Transfer with Positive Secrecy Capacity Channels

    Directory of Open Access Journals (Sweden)

    Mike Burmester

    2017-07-01

    Full Text Available The National Strategy for Global Supply Chain Security published in 2012 by the White House identifies two primary goals for strengthening global supply chains: first, to promote the efficient and secure movement of goods, and second to foster a resilient supply chain. The Internet of Things (IoT, and in particular Radio Frequency Identification (RFID technology, can be used to realize these goals. For product identification, tracking and real-time awareness, RFID tags are attached to goods. As tagged goods move along the supply chain from the suppliers to the manufacturers, and then on to the retailers until eventually they reach the customers, two major security challenges can be identified: (I to protect the shipment of goods that are controlled by potentially untrusted carriers; and (II to secure the transfer of ownership at each stage of the chain. For the former, grouping proofs in which the tags of the scanned goods generate a proof of “simulatenous” presence can be employed, while for the latter, ownership transfer protocols (OTP are used. This paper describes enhanced security solutions for both challenges. We first extend earlier work on grouping proofs and group codes to capture resilient group scanning with untrusted readers; then, we describe a modified version of a recently published OTP based on channels with positive secrecy capacity adapted to be implemented on common RFID systems in the supply chain. The proposed solutions take into account the limitations of low cost tags employed in the supply chain, which are only required to generate pseudorandom numbers and compute one-way hash functions.

  4. An RFID-Based Smart Structure for the Supply Chain: Resilient Scanning Proofs and Ownership Transfer with Positive Secrecy Capacity Channels.

    Science.gov (United States)

    Burmester, Mike; Munilla, Jorge; Ortiz, Andrés; Caballero-Gil, Pino

    2017-07-04

    The National Strategy for Global Supply Chain Security published in 2012 by the White House identifies two primary goals for strengthening global supply chains: first, to promote the efficient and secure movement of goods, and second to foster a resilient supply chain. The Internet of Things (IoT), and in particular Radio Frequency Identification (RFID) technology, can be used to realize these goals. For product identification, tracking and real-time awareness, RFID tags are attached to goods. As tagged goods move along the supply chain from the suppliers to the manufacturers, and then on to the retailers until eventually they reach the customers, two major security challenges can be identified: (I) to protect the shipment of goods that are controlled by potentially untrusted carriers; and (II) to secure the transfer of ownership at each stage of the chain. For the former, grouping proofs in which the tags of the scanned goods generate a proof of "simulatenous" presence can be employed, while for the latter, ownership transfer protocols (OTP) are used. This paper describes enhanced security solutions for both challenges. We first extend earlier work on grouping proofs and group codes to capture resilient group scanning with untrusted readers; then, we describe a modified version of a recently published OTP based on channels with positive secrecy capacity adapted to be implemented on common RFID systems in the supply chain. The proposed solutions take into account the limitations of low cost tags employed in the supply chain, which are only required to generate pseudorandom numbers and compute one-way hash functions.

  5. Indicators of abdominal size relative to height associated with sex, age, socioeconomic position and ancestry among US adults.

    Science.gov (United States)

    Kahn, Henry S; Bullard, Kai McKeever

    2017-01-01

    The supine sagittal abdominal diameter (SAD) and standing waist circumference (WC) describe abdominal size. The SAD/height ratio (SADHtR) or WC/height ratio (WHtR) may better identify cardiometabolic disorders than BMI (weight/height2), but population-based distributions of SADHtR and WHtR are not widely available. Abdominal adiposity may differ by sociodemographic characteristics. Anthropometry, including SAD by sliding-beam caliper, was performed on 9894 non-pregnant adults ≥20 years in the US National Health and Nutrition Examination Surveys of 2011-2014. Applying survey design factors and sampling weights, we estimated nationally representative SADHtR and WHtR distributions by sex, age, educational attainment, and four ancestral groups. The median (10th percentile, 90th percentile) for men's SADHtR was 0.130 (0.103, 0.165) and WHtR 0.569 (0.467, 0.690). For women, median SADHtR was 0.132 (0.102, 0.175) and WHtR 0.586 (0.473, 0.738). Medians for SADHtR and WHtR increased steadily through age 79. The median BMI, however, reached maximum values at ages 40-49 (men) or 60-69 (women) and then declined. Low educational attainment, adjusted for age and ancestry, was associated with elevated SADHtR more strongly than elevated BMI. While non-Hispanic Asians had substantially lower BMI compared to all other ancestral groups (adjusted for sex, age and education), their relative reductions in SADHtR and WHtR, were less marked. These cross-sectional data are consistent with monotonically increasing abdominal adipose tissue through the years of adulthood but decreasing mass in non-abdominal regions beyond middle age. They suggest also that visceral adipose tissue, estimated by SADHtR, expands differentially in association with low socioeconomic position. Insofar as Asians have lower BMIs than other populations, employing abdominal indicators may attenuate the adiposity differences reported between ancestral groups. Documenting the distribution and sociodemographic features

  6. ApoA-I/A-II-HDL positively associates with apoB-lipoproteins as a potential atherogenic indicator.

    Science.gov (United States)

    Kido, Toshimi; Kondo, Kazuo; Kurata, Hideaki; Fujiwara, Yoko; Urata, Takeyoshi; Itakura, Hiroshige; Yokoyama, Shinji

    2017-11-29

    We recently reported distinct nature of high-density lipoproteins (HDL) subgroup particles with apolipoprotein (apo) A-I but not apoA-II (LpAI) and HDL having both (LpAI:AII) based on the data from 314 Japanese. While plasma HDL level almost exclusively depends on concentration of LpAI having 3 to 4 apoA-I molecules, LpAI:AII appeared with almost constant concentration regardless of plasma HDL levels having stable structure with two apoA-I and one disulfide-dimeric apoA-II molecules (Sci. Rep. 6; 31,532, 2016). The aim of this study is further characterization of LpAI:AII with respect to its role in atherogenesis. Association of LpAI, LpAI:AII and other HDL parameters with apoB-lipoprotein parameters was analyzed among the cohort data above. ApoA-I in LpAI negatively correlated with the apoB-lipoprotein parameters such as apoB, triglyceride, nonHDL-cholesterol, and nonHDL-cholesterol + triglyceride, which are apparently reflected in the relations of the total HDL parameters to apoB-lipoproteins. In contrast, apoA-I in LpAI:AII and apoA-II positively correlated to the apoB-lipoprotein parameters even within their small range of variation. These relationships are independent of sex, but may slightly be influenced by the activity-related CETP mutations. The study suggested that LpAI:AII is an atherogenic indicator rather than antiatherogenic. These sub-fractions of HDL are to be evaluated separately for estimating atherogenic risk of the patients.

  7. Safety, Efficacy, Predictability and Stability Indices of Photorefractive Keratectomy for Correction of Myopic Astigmatism with Plano-Scan and Tissue-Saving Algorithms

    Directory of Open Access Journals (Sweden)

    Mehrdad Mohammadpour

    2013-10-01

    Full Text Available Purpose: To assess the safety, efficacy and predictability of photorefractive keratectomy (PRK [Tissue-saving (TS versus Plano-scan (PS ablation algorithms] of Technolas 217z excimer laser for correction of myopic astigmatismMethods: In this retrospective study one hundred and seventy eyes of 85 patients (107 eyes (62.9% with PS and 63 eyes (37.1% with TS algorithm were included. TS algorithm was applied for those with central corneal thickness less than 500 µm or estimated residual stromal thickness less than 420 µm. Mitomycin C (MMC was applied for 120 eyes (70.6%; in case of an ablation depth more than 60 μm and/or astigmatic correction more than one diopter (D. Mean sphere, cylinder, spherical equivalent (SE refraction, uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA were measured preoperatively, and 4 weeks,12 weeks and 24 weeks postoperatively.Results: One, three and six months postoperatively, 60%, 92.9%, 97.5% of eyes had UCVA of 20/20 or better, respectively. Mean preoperative and 1, 3, 6 months postoperative SE were -3.48±1.28 D (-1.00 to -8.75, -0.08±0.62D, -0.02±0.57 and -0.004± 0.29, respectively. And also, 87.6%, 94.1% and 100% were within ±1.0 D of emmetropia and 68.2, 75.3, 95% were within ±0.5 of emmetropia. The safety and efficacy indices were 0.99 and 0.99 at 12 weeks and 1.009 and 0.99 at 24 weeks, respectively. There was no clinically or statistically significant difference between the outcomes of PS or TS algorithms or between those with or without MMC in either group in terms of safety, efficacy, predictability or stability. Dividing the eyes with subjective SE≤4 D and SE≥4 D postoperatively, there was no significant difference between the predictability of the two groups. There was no intra- or postoperative complication.Conclusion: Outcomes of PRK for correction of myopic astigmatism showed great promise with both PS and TS algorithms.

  8. Scanning holograms

    International Nuclear Information System (INIS)

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  9. ST-Segment Depression in Hyperventilation Indicates a False Positive Exercise Test in Patients with Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Andreas P. Michaelides

    2010-01-01

    Full Text Available Objectives. Mitral valve prolapse (MVP is a known cause for false positive exercise test (ET. The purpose of this study was to establish additional electrocardiographic criteria to distinguish the false positive exercise results in patients with MVP. Methods. We studied 218 consecutive patients ( years, 103 males with MVP (according to echocardiographic study, and positive treadmill ET was performed due to multiple cardiovascular risk factors or angina-like symptoms. A coronary angiography was performed to detect coronary artery disease (CAD. Results. From 218 patients, 90 (group A presented with normal coronary arteries according to the angiography (false positive ET while the rest 128 (group B presented with CAD. ST-segment depression in hyperventilation phase was present in 54 patients of group A (60% while only in 14 patients of group B (11%, . Conclusions. Presence of ST-segment depression in hyperventilation phase favors a false positive ET in patients with MVP.

  10. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States); Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States)

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  11. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    International Nuclear Information System (INIS)

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S.

    2012-01-01

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II–IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  12. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  13. Disciplinary style and child abuse potential: association with indicators of positive functioning in children with behavior problems.

    Science.gov (United States)

    Rodriguez, Christina M; Eden, Ann M

    2008-06-01

    Reduction of ineffective parenting is promoted in parent training components of mental health treatment for children with externalizing behavior disorders, but minimal research has considered whether disciplinary style and lower abuse risk could also be associated with positive functioning in such children. The present study examined whether lower dysfunctional disciplinary style and child abuse risk was associated with children's positive self-concept, adaptive attributional style, and hopefulness. Recruited from children undergoing treatment for disruptive behavior disorders, 69 mother-child dyads participated, with maternal caregivers reporting on their disciplinary style and abuse potential and children reporting independently on their positive functioning (adaptive attributional style, overall self-concept, and hopelessness). Findings supported the hypothesized association, with lower scores on mothers' dysfunctional discipline style and abuse potential significantly predicting children's reported positive functioning. Future research directions pertaining to more adaptive functioning in children with behavior problems are discussed.

  14. Toward a Progress Indicator for Machine Learning Model Building and Data Mining Algorithm Execution: A Position Paper

    Science.gov (United States)

    Luo, Gang

    2017-01-01

    For user-friendliness, many software systems offer progress indicators for long-duration tasks. A typical progress indicator continuously estimates the remaining task execution time as well as the portion of the task that has been finished. Building a machine learning model often takes a long time, but no existing machine learning software supplies a non-trivial progress indicator. Similarly, running a data mining algorithm often takes a long time, but no existing data mining software provides a nontrivial progress indicator. In this article, we consider the problem of offering progress indicators for machine learning model building and data mining algorithm execution. We discuss the goals and challenges intrinsic to this problem. Then we describe an initial framework for implementing such progress indicators and two advanced, potential uses of them, with the goal of inspiring future research on this topic. PMID:29177022

  15. Differential scanning calorimetry of whole Escherichia coli treated with the antimicrobial peptide MSI-78 indicate a multi-hit mechanism with ribosomes as a novel target

    Directory of Open Access Journals (Sweden)

    Alexander M. Brannan

    2015-12-01

    Full Text Available Differential Scanning Calorimetry (DSC of intact Escherichia coli (E. coli was used to identify non-lipidic targets of the antimicrobial peptide (AMP MSI-78. The DSC thermograms revealed that, in addition to its known lytic properties, MSI-78 also has a striking effect on ribosomes. MSI-78’s effect on DSC scans of bacteria was similar to that of kanamycin, an antibiotic drug known to target the 30S small ribosomal subunit. An in vitro transcription/translation assay helped confirm MSI-78’s targeting of ribosomes. The scrambled version of MSI-78 also affected the ribosome peak of the DSC scans, but required greater amounts of peptide to cause a similar effect to the unscrambled peptide. Furthermore, the effect of the scrambled peptide was not specific to the ribosomes; other regions of the DSC thermogram were also affected. These results suggest that MSI-78’s effects on E. coli are at least somewhat dependent on its particular structural features, rather than a sole function of its overall charge and hydrophobicity. When considered along with earlier work detailing MSI-78’s membrane lytic properties, it appears that MSI-78 operates via a multi-hit mechanism with multiple targets.

  16. Disciplinary Style and Child Abuse Potential: Association with Indicators of Positive Functioning in Children with Behavior Problems

    Science.gov (United States)

    Rodriguez, Christina M.; Eden, Ann M.

    2008-01-01

    Reduction of ineffective parenting is promoted in parent training components of mental health treatment for children with externalizing behavior disorders, but minimal research has considered whether disciplinary style and lower abuse risk could also be associated with positive functioning in such children. The present study examined whether lower…

  17. [False positive results or what's the probability that a significant P-value indicates a true effect?

    Science.gov (United States)

    Cucherat, Michel; Laporte, Silvy

    2017-09-01

    The use of statistical test is central in the clinical trial. At the statistical level, obtaining a Pinformation about the plausibility of the existence of treatment effect. With "Pfalse positive is very high. This is the case if the power is low, if there is an inflation of the alpha risk or if the result is exploratory or chance discoveries. This possibility is important to take into consideration when interpreting the results of clinical trials in order to avoid pushing ahead significant results in appearance, but which are likely to be actually false positive results. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  18. The strength of two indicators of social position on oral health among persons over the age of 80 years

    DEFF Research Database (Denmark)

    Avlund, Kirsten; Holm-Pedersen, Poul; Morse, Douglas E

    2005-01-01

    OBJECTIVE: The objective of the present study is to analyze how two dimensions of social position, education and social class, are associated with oral health among generally healthy, community-dwelling persons over the age of 80 years. METHODS: The present investigation is based on a sample of 157...... community-dwelling individuals from The Kungsholmen Elders Oral Health Study (KEOHS) and included data from interviews and oral examinations. Social position was measured by education and social class. Oral health was measured by active coronal caries, active root caries, edentulism and use of dental...... of being edentulous. Further, persons with elementary/ medium education tended to forego regular dental services more than persons with high education. CONCLUSION: The study identified social inequalities in oral health even in a population of independently living, generally healthy very old Swedes...

  19. Scanning of bone metastases

    International Nuclear Information System (INIS)

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  20. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  1. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou, Yong-Kang, E-mail: zhouyk2009@163.com; Chen, Yi-Xing, E-mail: chen.yixing@zs-hospital.sh.cn; Shi, Shi-Ming, E-mail: shiming32@126.com; Zeng, Zhao-Chong, E-mail: zeng.zhaochong@zs-hospital.sh.cn [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180 Feng Lin Road, Shanghai 200032 (China)

    2016-07-15

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  2. Analysis of a Novel Diffractive Scanning-Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

    International Nuclear Information System (INIS)

    Tatchyn, R.

    2011-01-01

    Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPM with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r and d) tasks for fabricating and testing the proposed BPM are discussed.

  3. A cause of false positive of the whole body scanning with iodine 131: obstructive hydronephrosis; Une cause de faux-positif du balayage corps entier a l'iode 131: l'hydronephrose obstructive

    Energy Technology Data Exchange (ETDEWEB)

    Sellem, A.; Elbez, I.; Rejeb, O.; Elkadri, N.; Hammami, H. [Service de medecine nucleaire, hopital Militaire, Tunis, (Tunisia)

    2009-05-15

    The objective is to report the case of a differentiated carcinoma of the thyroid with a false positive aspect to the whole-body scanning with iodine 131 in relation with an accumulation of the tracer at the level of an obstructive appearance hydronephrosis. (N.C.)

  4. Influence of Lymphatic Invasion on Locoregional Recurrence Following Mastectomy: Indication for Postmastectomy Radiotherapy for Breast Cancer Patients With One to Three Positive Nodes

    International Nuclear Information System (INIS)

    Matsunuma, Ryoichi; Oguchi, Masahiko; Fujikane, Tomoko; Matsuura, Masaaki; Sakai, Takehiko; Kimura, Kiyomi; Morizono, Hidetomo; Iijima, Kotaro; Izumori, Ayumi; Miyagi, Yumi; Nishimura, Seiichiro; Makita, Masujiro; Gomi, Naoya; Horii, Rie; Akiyama, Futoshi; Iwase, Takuji

    2012-01-01

    Purpose: The indication for postmastectomy radiotherapy (PMRT) in breast cancer patients with one to three positive lymph nodes has been in discussion. The purpose of this study was to identify patient groups for whom PMRT may be indicated, focusing on varied locoregional recurrence rates depending on lymphatic invasion (ly) status. Methods and Materials: Retrospective analysis of 1,994 node-positive patients who had undergone mastectomy without postoperative radiotherapy between January 1990 and December 2000 at our hospital was performed. Patient groups for whom PMRT should be indicated were assessed using statistical tests based on the relationship between locoregional recurrence rate and ly status. Results: Multivariate analysis showed that the ly status affected the locoregional recurrence rate to as great a degree as the number of positive lymph nodes (p < 0.001). Especially for patients with one to three positive nodes, extensive ly was a more significant factor than stage T3 in the TNM staging system for locoregional recurrence (p < 0.001 vs. p = 0.295). Conclusion: Among postmastectomy patients with one to three positive lymph nodes, patients with extensive ly seem to require local therapy regimens similar to those used for patients with four or more positive nodes and also seem to require consideration of the use of PMRT.

  5. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  6. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  7. A real-world comparison of apnea-hypopnea indices of positive airway pressure device and polysomnography.

    Directory of Open Access Journals (Sweden)

    Ritwick Agrawal

    Full Text Available The apnea hypopnea index (AHI reported by positive airway pressure (PAP device is widely used in clinical practice, yet its correlation with standardized AHI obtained during the sleep study is not established. The current study was conducted to investigate the correlation between AHI estimated by the PAP device and reported on the smart card with the AHI found during the PAP polysomnography (PSG in the "real world" setting at an academic sleep center. We retrospectively reviewed the medical records of 280 patients who underwent a PAP titration PSG at Drexel sleep center, and were later prescribed a PAP device. The AHI was categorized in clinically relevant subgroups (as AHI ≤5 and AHI >5. The AHI at the final pressure on the PSG and the average AHI from the prescribed PAP device were compared. The results showed that in the majority (77.3% of patients (126 of 163, the AHI from both PAP device and PSG correlated well and were in the same category (AHI ≤5 and AHI >5 respectively. The majority of patients (80.7% with PSG AHI of 5, 61.5% patients reported good control, with AHI <5 on PAP device AHI. We conclude that in a majority of patients who were optimally titrated in the sleep laboratory, the PAP device continued to show optimal control at home.

  8. A validation of 11 body-condition indices in a giant snake species that exhibits positive allometry.

    Directory of Open Access Journals (Sweden)

    Bryan G Falk

    Full Text Available Body condition is a gauge of the energy stores of an animal, and though it has important implications for fitness, survival, competition, and disease, it is difficult to measure directly. Instead, body condition is frequently estimated as a body condition index (BCI using length and mass measurements. A desirable BCI should accurately reflect true body condition and be unbiased with respect to size (i.e., mean BCI estimates should not change across different length or mass ranges, and choosing the most-appropriate BCI is not straightforward. We evaluated 11 different BCIs in 248 Burmese pythons (Python bivittatus, organisms that, like other snakes, exhibit simple body plans well characterized by length and mass. We found that the length-mass relationship in Burmese pythons is positively allometric, where mass increases rapidly with respect to length, and this allowed us to explore the effects of allometry on BCI verification. We employed three alternative measures of 'true' body condition: percent fat, scaled fat, and residual fat. The latter two measures mostly accommodated allometry in true body condition, but percent fat did not. Our inferences of the best-performing BCIs depended heavily on our measure of true body condition, with most BCIs falling into one of two groups. The first group contained most BCIs based on ratios, and these were associated with percent fat and body length (i.e., were biased. The second group contained the scaled mass index and most of the BCIs based on linear regressions, and these were associated with both scaled and residual fat but not body length (i.e., were unbiased. Our results show that potential differences in measures of true body condition should be explored in BCI verification studies, particularly in organisms undergoing allometric growth. Furthermore, the caveats of each BCI and similarities to other BCIs are important to consider when determining which BCI is appropriate for any particular taxon.

  9. SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation

    International Nuclear Information System (INIS)

    Liu, H; Gao, Y; Xu, X; Zhuo, W; Wu, J

    2015-01-01

    Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulation (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)

  10. HLA similarities indicate shared genetic risk in 21-hydroxylase autoantibody positive South African and United States Addison's disease.

    Science.gov (United States)

    Ross, I L; Babu, S; Armstrong, T; Zhang, L; Schatz, D; Pugliese, A; Eisenbarth, G; Baker Ii, P

    2014-10-01

    Genetic similarities between patients from the United States and South African (SA) Addison's Disease (AD) strengthen evidence for genetic association. SA-AD (n = 73), SA healthy controls (N = 78), and US-AD patients (N = 83) were genotyped for DQA1, DQB1, DRB1, and HLA-B alleles. Serum was tested for the quantity of 21OH-AA and IFNα-AA at the Barbara Davis Center. Although not as profound as in US-AD, in SA-AD 21OH-AA + subjects the predominantly associated risk haplotypes were DRB1*0301-DQB1*0201 (DR3), DRB1*04xx-DQB1*0302 (DR4), and the combined DR3/4 genotype. DQB1*0302 associated DRB1*04xx haplotypes conferred higher risk than those DRB1*04xx haplotypes associated with other DQB1 alleles. We found negative association in 21OH-AA + SA-AD for DQA1*0201-DQB1*0202 and DQA1*0101-DQB1*0501 vs SA controls, and positive association for DQA1*0401-DQB1*0402 vs US-AD. Apart from the class II DR3 haplotype, HLA-B8 did not have an independent effect; however together DR3 and HLA-B8 conferred the highest risk vs 21OH-AA negative SA-AD and SA-controls. HLA-B7 (often with DR4) conferred novel risk in 21OH-AA + SA-AD vs controls. This study represents the first comparison between South African and United States AD populations utilizing genotyping and serology performed at the same center. SA-AD and US-AD 21OH-AA + patients share common HLA risk haplotypes including DR4 (with HLA-B7) and DR3 (with HLA-B8), strengthening previously described HLA associations and implicating similar genetic etiology. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Contouring and Constraining Bowel on a Full-Bladder Computed Tomography Scan May Not Reflect Treatment Bowel Position and Dose Certainty in Gynecologic External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yaparpalvi, Ravindra, E-mail: ryaparpa@montefiore.org; Mehta, Keyur J.; Bernstein, Michael B.; Kabarriti, Rafi; Hong, Linda X.; Garg, Madhur K.; Guha, Chandan; Kalnicki, Shalom; Tomé, Wolfgang A.

    2014-11-15

    Purpose: To evaluate, in a gynecologic cancer setting, changes in bowel position, dose-volume parameters, and biological indices that arise between full-bladder (FB) and empty-bladder (EB) treatment situations; and to evaluate, using cone beam computed tomography (CT), the validity of FB treatment presumption. Methods and Materials: Seventeen gynecologic cancer patients were retrospectively analyzed. Empty-bladder and FB CTs were obtained. Full-bladder CTs were used for planning and dose optimization. Patients were given FB instructions for treatment. For the study purpose, bowel was contoured on the EB CTs for all patients. Bowel position and volume changes between FB and EB states were determined. Full-bladder plans were applied on EB CTs for determining bowel dose-volume changes in EB state. Biological indices (generalized equivalent uniform dose and normal tissue complication probability) were calculated and compared between FB and EB. Weekly cone beam CT data were available in 6 patients to assess bladder volume at treatment. Results: Average (±SD) planned bladder volume was 299.7 ± 68.5 cm{sup 3}. Median bowel shift in the craniocaudal direction between FB and EB was 12.5 mm (range, 3-30 mm), and corresponding increase in exposed bowel volume was 151.3 cm{sup 3} (range, 74.3-251.4 cm{sup 3}). Absolute bowel volumes receiving 45 Gy were higher for EB compared with FB (mean 328.0 ± 174.8 vs 176.0 ± 87.5 cm{sup 3}; P=.0038). Bowel normal tissue complication probability increased 1.5× to 23.5× when FB planned treatments were applied in the EB state. For the study, the mean percentage value of relative bladder volume at treatment was 32%. Conclusions: Full-bladder planning does not necessarily translate into FB treatments, with a patient tendency toward EB. Given the uncertainty in daily control over bladder volume for treatment, we strongly recommend a “planning-at-risk volume bowel” (PRV{sub B}owel) concept to account for bowel motion

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... but is often performed on hospitalized patients as well. Thyroid Scan You will be positioned on an ...

  13. Comparative Functional Alanine Positional Scanning of the α-Melanocyte Stimulating Hormone and NDP-Melanocyte Stimulating Hormone Demonstrates Differential Structure-Activity Relationships at the Mouse Melanocortin Receptors.

    Science.gov (United States)

    Todorovic, Aleksandar; Ericson, Mark D; Palusak, Ryan D; Sorensen, Nicholas B; Wood, Michael S; Xiang, Zhimin; Haskell-Luevano, Carrie

    2016-07-20

    The melanocortin system has been implicated in the regulation of various physiological functions including melanogenesis, steroidogenesis, energy homeostasis, and feeding behavior. Five melanocortin receptors have been identified to date and belong to the family of G protein-coupled receptors (GPCR). Post-translational modification of the proopiomelanocortin (POMC) prohormone leads to the biosynthesis of the endogenous melanocortin agonists, including α-melanocyte stimulating hormone (α-MSH), β-MSH, γ-MSH, and adrenocorticotropic hormone (ACTH). All the melanocortin agonists derived from the POMC prohormone contain a His-Phe-Arg-Trp tetrapeptide sequence that has been implicated in eliciting the pharmacological responses at the melanocortin receptors. Herein, an alanine (Ala) positional scan is reported for the endogenous α-MSH ligand and the synthetic, more potent, NDP-MSH peptide (Ac-Ser(1)-Tyr(2)-Ser(3)-Nle(4)-Glu(5)-His(6)-DPhe(7)-Arg(8)-Trp(9)-Gly(10)-Lys(11)-Pro(12)-Val(13)-NH2) at the cloned mouse melanocortin receptors to test the assumption that the structure-activity relationships of one ligand would apply to the other. Several residues outside of the postulated pharmacophore altered potency at the melanocortin receptors, most notably the 1560-, 37-, and 15-fold potency loss when the Glu(5) position of α-MSH was substituted with Ala at the mMC1R, mMC3R, and mMC4R, respectively. Importantly, the altered potencies due to Ala substitutions in α-MSH did not necessarily correlate with equivalent Ala substitutions in NDP-MSH, indicating that structural modifications and corresponding biological activities in one of these melanocortin ligands may not be predictive for the other agonist.

  14. A close or positive margin after mastectomy is not an indication for chest wall irradiation except in women aged fifty or younger

    International Nuclear Information System (INIS)

    Freedman, Gary M.; Fowble, Barbara L.; Hanlon, Alexandra L.; Myint, Maung A.; Hoffman, John P.; Sigurdson, Elin R.; Eisenberg, Burton L.; Goldstein, Lori J.; Fein, Douglas A.

    1998-01-01

    Introduction: Indications for postmastectomy radiation include primary tumor size ≥5 cm and/or ≥4 positive axillary nodes. In clinical practice, patients with a close or positive margin after mastectomy are also often treated with postmastectomy radiation. However, there is little data regarding the risk of a chest wall recurrence in patients with close or positive margins who otherwise would be considered low risk (tumor size 50 (p = 0.04). There was no correlation with chest wall failure and number of positive nodes, ER status, lymphovascular invasion, location of primary, grade, family history, or type of tumor close to the margin. Of 5 chest wall failures, 4 were in patients who had received adjuvant systemic chemotherapy ± tamoxifen. Chest wall failures occurred in 1 patient with a positive deep margin, 3 patients with margins within 2 mm, and 1 patient with a margin of 5 mm. The estimated cumulative incidence probability of chest wall recurrence at 8 years by margin proximity was 24% ≤ 2 mm vs. 7% 2.1-6 mm (p = 0.36), and by clinical size 24% for T2 tumors vs. 7% for T1 (p = 0.98). Conclusions: A close or positive margin is uncommon (≤5%) after mastectomy in patients with tumor size <5 cm and 0-3 positive axillary nodes but, when present, it appears to be in a younger patient population. The subgroup of patients aged 50 or younger with clinical T1-T2 tumor size and 0-3 positive nodes who have a close (≤5 mm) or positive mastectomy margin are at high risk (28% at 8 years) for chest wall recurrence regardless of adjuvant systemic therapy and, therefore, should be considered for postmastectomy radiation

  15. Next-generation sequencing indicates false-positive MRD results and better predicts prognosis after SCT in patients with childhood ALL.

    Science.gov (United States)

    Kotrova, M; van der Velden, V H J; van Dongen, J J M; Formankova, R; Sedlacek, P; Brüggemann, M; Zuna, J; Stary, J; Trka, J; Fronkova, E

    2017-07-01

    Minimal residual disease (MRD) monitoring via quantitative PCR (qPCR) detection of Ag receptor gene rearrangements has been the most sensitive method for predicting prognosis and making post-transplant treatment decisions for patients with ALL. Despite the broad clinical usefulness and standardization of this method, we and others have repeatedly reported the possibility of false-positive MRD results caused by massive B-lymphocyte regeneration after stem cell transplantation (SCT). Next-generation sequencing (NGS) enables precise and sensitive detection of multiple Ag receptor rearrangements, thus providing a more specific readout compared to qPCR. We investigated two cohorts of children with ALL who underwent SCT (30 patients and 228 samples). The first cohort consisted of 17 patients who remained in long-term CR after SCT despite having low MRD positivity (SCT monitoring using qPCR. Only one of 27 qPCR-positive samples was confirmed to be positive by NGS. Conversely, 10 of 15 samples with low qPCR-detected MRD positivity from 13 patients who subsequently relapsed were also confirmed to be positive by NGS (P=0.002). These data show that NGS has a better specificity in post-SCT ALL management and indicate that treatment interventions aimed at reverting impending relapse should not be based on qPCR only.

  16. “THE NET MONETARY STATEMENT” AND “THE NET NON-MONETARY STATEMENT” – ASSESSMENT INDICATORS FOR THE FINANCIAL POSITION OF THE ENTITY

    Directory of Open Access Journals (Sweden)

    SORIN-CONSTANTIN DEACONU

    2012-10-01

    Full Text Available This paper examines two indicators, namely the net monetary statement and the net non-monetary statement. To determine and analyze them, we started with the classification of assets (monetary and non-monetary and liabilities (monetary and nonmonetary. The actual values of these elements were established on the basis of information supplied by the balance sheet, followed by the calculus of the net monetary statement and of the net non-monetary statement. These indicators provide relevant and reliable information to the users of financial statements and, in the future, they should be taken into account because they bring additional information about the financial position of the entity.

  17. Cooperative scans

    NARCIS (Netherlands)

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  18. [Relationships between Myers-Briggs Type Indicator (MBTI) psychological type and marital satisfaction, divorce proneness, positive affect, and conflict regulation in clinic couples].

    Science.gov (United States)

    Kong, Seong Sook

    2010-06-01

    The purpose of the study was to investigate the relationships between the Myers-Briggs Type Indicator (MBTI) psychological type and marital satisfaction, divorce proneness, positive affect, and conflict regulation in couple visiting a clinic. Couples (n=62) who visited "M" couple clinic participated in the study. Data were collected from March to June 2009 using the Marital Satisfaction Scale, Marital Status Inventory, Positive Affect Inventory, and Conflict Regulation Inventory. The couples showed no significant differences in marital satisfaction, positive affect, and conflict regulation according to similarities between spouses in MBTI types. However, they showed significant differences in divorce proneness of husband according to a similarity in the Sensing/Intuition indicator. They also showed significant differences in divorce proneness, positive affect, and conflict regulation between the couples for ISTJ (Introversion, Sensing, Thinking, Judging) or ESTJ (Extraversion, Sensing, Thinking, Judging) types compared to other couples. When nurses counsel couples, they should understand that differences in psychological type between spouses affects their marital relationship. In addition, nurses should educate couples on the characteristics of each type according to the couple's types and help them to understand each other, especially for couples where one spouse is the ISTJ/ESTJ type. These interventions will improve marital satisfaction and prevent the divorce in these couples.

  19. Project W-314 acceptance test report HNF-4643 for HNF-4642 241-AN-A valve pit manifold valves and position indication for project W-314

    International Nuclear Information System (INIS)

    HAMMERS, J.S.

    1999-01-01

    The purpose of the test was to verify that the AN Tank Farm Manifold Valves can be manually manipulated to the required operating position and that the electrical and visual indications accurately reflect that position. Physical locking devices were also verified to function. The Acceptance Test Procedure HNF-4642, 241-AN-A Valve Pit Manifold Valves and Position Indication was conducted between 23 June and 10 August 1999 at the 200E AN Tank Farm. The test has no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed, this had an impact on the procedure and test results, ECN 653752 was written to correct the mismatch between the procedure and actual field conditions. P and ID H-14-100941 was changed via ECN-W-314-4C-120. All components, identified in the procedure, were not found to be labeled and identified as written in the procedure, temporary tags were used for operational identification. A retest of valve ANA-WT-V 318 was required because it was removed from its installed position and modified after testing was completed

  20. The abdominal technetium scan (a decade of experience)

    International Nuclear Information System (INIS)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.; Karp, M.P.; Jewett, T.C. Jr.

    1982-01-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans, 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients

  1. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  2. Bone scans in nasopharyngeal carcinoma: local experience

    International Nuclear Information System (INIS)

    Tiong, S.

    2004-01-01

    correct in the true positive group of patients but uncertain in the false negative group.The incidence of positive bone scans appears to suggest relatively higher rate of bone metastasis in the patients of advanced stages. Conclusion: The number of present series of NPC patients studied and the relative incidences of true and false positives are small. However the findings indicate that bone scans using TC99 is a good screening test as it helps Clinicians realize the sites of likely metastasis and decision for further confirmatory X ray imagings; this is especially true in the case of treated patients.It is hoped that the patient sample size will be increased in the future for improved assessment and evaluation. (authors)

  3. A close or positive margin after mastectomy is not an indication for chest wall irradiation except in women aged fifty or younger

    International Nuclear Information System (INIS)

    Freedman, G.M.; Fowble, B.L.; Hanlon, A.L.; Myint, M.A.; Hoffman, J.P.; Sigurdson, E.R.; Eisenberg, B.L.; Goldstein, L.J.; Fein, D.A.

    1997-01-01

    Purpose: Indications for postmastectomy radiation include primary tumor size > 5 cm and ≥ 4 positive axillary nodes. In clinical practice, patients with a close or positive margin after mastectomy are also often treated with postmastectomy radiation. However, there is little data regarding the risk of a chest wall recurrence in patients with this pathologic feature who otherwise would be considered low risk (tumor size 25% at 8 years: Age ≤ 50 years was 28% vs. 0% for age > 50 (p=0.08). There was no correlation with chest wall failure and number of nodes, ER status, lymphovascular invasion, location of primary, grade, family history or type of tumor close to the margin. All four chest wall failures were in patients who had received adjuvant systemic chemotherapy ± Tamoxifen. Chest wall failures occurred in patients with margins within 1-2 mm in three patients and 5 mm in one patient. The cumulative chest wall recurrence at 8 years by margin proximity was 24% ≤ 2mm vs. 7% 2.1-6 mm (p=0.44), and by clinical size 24% for T2 tumors vs. 7% for T1 (p=0.55). Conclusions: A close or positive margin is uncommon (< 5%) after mastectomy in patients with tumor size < 5 cm and 0-3 positive axillary nodes, but when present it appears to be in a younger patient population. The subgroup of patients aged 50 or younger with clinical T1-T2 tumor size and 0-3 positive nodes who have a close (≤ 5 mm) or positive mastectomy margin are at high risk (28% at 8 years) for chest wall recurrence regardless of adjuvant systemic therapy, and therefore we recommend they be considered for postmastectomy radiation. This high risk of local failure was not observed in patients over age 50, suggesting this subgroup may not require adjuvant chest wall irradiation

  4. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  5. Study of individual and group affective processes in the crew of a simulated mission to Mars: Positive affectivity as a valuable indicator of changes in the crew affectivity

    Science.gov (United States)

    Poláčková Šolcová, Iva; Lačev, Alek; Šolcová, Iva

    2014-07-01

    The success of a long-duration space mission depends on various technical demands as well as on the psychological (cognitive, affective, and motivational) adaptation of crewmembers and the quality of interactions within the crew. We examined the ways crewmembers of a 520-day simulated spaceflight to Mars (held in the Institute for Biomedical Problems, in Moscow) experienced and regulated their moods and emotions. Results show that crewmembers experienced predominantly positive emotions throughout their 520-day isolation and the changes in mood of the crewmembers were asynchronous and balanced. The study suggests that during the simulation, crewmembers experienced and regulated their emotions differently than they usually do in their everyday life. In isolation, crewmembers preferred to suppress and neutralize their negative emotions and express overtly only emotions with positive valence. Although the affective processes were almost invariable throughout the simulation, two periods of time when the level of positive emotions declined were identified. Regarding the findings, the paper suggests that changes in positive affectivity could be a more valuable indicator of human experience in demanding but professional environments than changes in negative affectivity. Finally, the paper discusses the phenomenology of emotions during a real space mission.

  6. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    Directory of Open Access Journals (Sweden)

    Zhang Jian

    2013-01-01

    Full Text Available Abstract Background Whether PET scan maximum standard uptake value (SUVmax could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC patients with luminal subtype is still unknown and need to be investigated. Methods 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. Results In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS or overall survival (OS after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. Conclusions SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype.

  7. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    International Nuclear Information System (INIS)

    Zhang, Jian; Hu, Xi-Chun; Jia, Zhen; Ragaz, Joseph; Zhang, Ying-Jian; Zhou, Min; Zhang, Yong-Ping; Li, Gang; Wang, Bi-Yun; Wang, Zhong-Hua

    2013-01-01

    Whether PET scan maximum standard uptake value (SUVmax) could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC) patients with luminal subtype is still unknown and need to be investigated. 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS) or overall survival (OS) after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype

  8. Polyethylene glycol-covered ultra-small Gd2O3 nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning

    Science.gov (United States)

    Fortin, Marc-André; Petoral, Rodrigo M., Jr.; Söderlind, Fredrik; Klasson, A.; Engström, Maria; Veres, Teodor; Käll, Per-Olof; Uvdal, Kajsa

    2007-10-01

    The size distribution and magnetic properties of ultra-small gadolinium oxide crystals (US-Gd2O3) were studied, and the impact of polyethylene glycol capping on the relaxivity constants (r1, r2) and signal intensity with this contrast agent was investigated. Size distribution and magnetic properties of US-Gd2O3 nanocrystals were measured with a TEM and PPMS magnetometer. For relaxation studies, diethylene glycol (DEG)-capped US-Gd2O3 nanocrystals were reacted with PEG-silane (MW 5000). Suspensions were adequately dialyzed in water to eliminate traces of Gd3+ and surfactants. The particle hydrodynamic radius was measured with dynamic light scattering (DLS) and the proton relaxation times were measured with a 1.5 T MRI scanner. Parallel studies were performed with DEG-Gd2O3 and PEG-silane-SPGO (Gd2O3,DTPA and the r2/r1 ratio was 1.4. PEG-silane-SPGO gave low r1 relaxivities and high r2/r1 ratios, less compatible with positive contrast agent requirements. Higher r1 were obtained with PEG-silane in comparison to DEG-Gd2O3. Treatment of DEG-US-Gd2O3 with PEG-silane provides enhanced relaxivity while preventing aggregation of the oxide cores. This study confirms that PEG-covered Gd2O3 nanoparticles can be used for positively contrasted MR applications requiring stability, biocompatible coatings and nanocrystal functionalization.

  9. Scanning table

    CERN Multimedia

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  10. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  11. Capsinoids activate brown adipose tissue (BAT) with increased energy expenditure associated with subthreshold 18-fluorine fluorodeoxyglucose uptake in BAT-positive humans confirmed by positron emission tomography scan.

    Science.gov (United States)

    Sun, Lijuan; Camps, Stefan G; Goh, Hui Jen; Govindharajulu, Priya; Schaefferkoetter, Joshua D; Townsend, David W; Verma, Sanjay K; Velan, S Sendhil; Sun, Lei; Sze, Siu Kwan; Lim, Su Chi; Boehm, Bernhard Otto; Henry, Christiani Jeyakumar; Leow, Melvin Khee-Shing

    2018-01-01

    Capsinoids are reported to increase energy expenditure (EE) via brown adipose tissue (BAT) stimulation. However, imaging of BAT activation by capsinoids remains limited. Because BAT activation is a potential therapeutic strategy for obesity and related metabolic disorders, we sought to prove that capsinoid-induced BAT activation can be visualized by 18-fluorine fluorodeoxyglucose (18F-FDG) positron emission tomography (PET). We compared capsinoids and cold exposure on BAT activation and whole-body EE. Twenty healthy participants (8 men, 12 women) with a mean age of 26 y (range: 21-35 y) and a body mass index (kg/m2) of 21.7 (range: 18.5-26.0) underwent 18F-FDG PET and whole-body calorimetry after ingestion of 12 mg capsinoids or ≤2 h of cold exposure (∼14.5°C) in a crossover design. Mean standardized uptake values (SUVs) of the region of interest and BAT volumes were calculated. Blood metabolites were measured before and 2 h after each treatment. All of the participants showed negligible 18F-FDG uptake post-capsinoid ingestion. Upon cold exposure, 12 participants showed avid 18F-FDG uptake into supraclavicular and lateral neck adipose tissues (BAT-positive group), whereas the remaining 8 participants (BAT-negative group) showed undetectable uptake. Capsinoids and cold exposure increased EE, although cold induced a 2-fold increase in whole-body EE and higher fat oxidation, insulin sensitivity, and HDL cholesterol compared with capsinoids. Capsinoids only increased EE in BAT-positive participants, which suggests that BAT mediates EE evoked by capsinoids. This implies that capsinoids stimulate BAT to a lesser degree than cold exposure as evidenced by 18F-FDG uptake below the presently accepted SUV thresholds defining BAT activation. This trial was registered at www.clinicaltrials.gov as NCT02964442. © 2018 American Society for Nutrition. All rights reserved.

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... process that regulates the rate at which the body converts food to energy. top of page What are some common uses of the procedure? The thyroid scan is used to determine the size, shape and position of the thyroid gland. The ...

  13. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  14. Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)

    International Nuclear Information System (INIS)

    Sciagra, Roberto; Passeri, Alessandro; Bucerius, Jan; Verberne, Hein J.; Slart, Riemer H.J.A.; Lindner, Oliver; Gimelli, Alessia; Hyafil, Fabien; Agostini, Denis; Uebleis, Christopher; Hacker, Marcus

    2016-01-01

    Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice. (orig.)

  15. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    Science.gov (United States)

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  16. Multiple myeloma: radiology or bone scanning

    International Nuclear Information System (INIS)

    Leonard, R.C.F.; Owen, J.P.; Proctor, S.J.; Hamilton, P.J.

    1981-01-01

    A comparative study of radionuclide bone scanning and skeletal radiology in patients with multiple myeloma revealed four principal findings: (i) There were no cases of negative bone scans with positive skeletal radiographs. (ii) Lytic bone lesions were seriously underestimated by bone scans. (iii) Bone scans tended to pick up lesions in ribs missed on the skeletal surveys. (iv) Patients with bone pain were more likely to have positive bone scans and skeletal radiographs than asymptomatic patients. (author)

  17. The positive correlation of the CCL2-CCR2 axis with the disease activity may indicate the fundamental role in the pathogenesis of oral lichen planus.

    Science.gov (United States)

    Yin, Jingfang; Yang, Xi; Zeng, Qi; Yang, Linglan; Cheng, Bin; Tao, Xiaoan

    2016-01-01

    The important roles of CCL2 and its receptor CCR2 had been reported in a series of inflammatory disorders. However, few studies investigated the potential role of CCL2/CCR2 axis in oral lichen planus (OLP). Therefore, this study aimed to detect the expression of CCL2 and CCR2 in OLP lesions and compare their changes before and after treatment. CCL2 and CCR2 expression was investigated using immunohistochemical staining and real-time RT-PCR in 32 patients with OLP and eight controls. Moreover, changes in their expression after treatment with triamcinolone acetonide were assessed in lesions from three patients. CCL2+ and CCR2+ cells were few in the controls and remarkably increased in the epithelial and subepithelial layers of lesions (n = 32, all P < 0.001). However, the densities of CCL2+ and CCR2+ cells were not significantly different between reticular (n = 12) and erythematous/erosive lesions (n = 20), although they significantly decreased after treatment (627.7 ± 108.2 vs. 258.3 ± 148.3, P = 0.017; 1034.7 ± 74.6 vs. 648 ± 77.6, P = 0.003, respectively). CCL2+/CCR2+ cell numbers were positively correlated with disease activity (correlation coefficient, 0.588; P < 0.001; correlation coefficient, 0.409; P = 0.02, respectively). The results of this study indicated that the CCL2-CCR2 axis was involved in the pathogenesis of OLP and was positively correlated with disease activity. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  19. Clinical indications to the use of Tc-99m-EDDA/HYNIC-TOC to detect somatostatin receptor-positive neuroendocrine tumors

    NARCIS (Netherlands)

    Parisella, M. G.; Chianelli, M.; D'Alessandria, C.; Todino, V.; Mikolajczak, R.; Papini, E.; Dierckx, R. A.; Scopinaro, F.; Signore, A.

    The aim of this study was to define, retrospectively, the utility to perform Tc-99m-EDDA/HYNIC-Tyr3-octreotide (Tc-99m-EDDA/HYNIC-TOC) scan in patients with NET. We studied 50 consecutive patients affected by different types of NET and divided in two groups. Group 1: 34 patients with known lesions

  20. Prediction value of the Canadian CT head rule and the New Orleans criteria for positive head CT scan and acute neurosurgical procedures in minor head trauma: a multicenter external validation study.

    Science.gov (United States)

    Bouida, Wahid; Marghli, Soudani; Souissi, Sami; Ksibi, Hichem; Methammem, Mehdi; Haguiga, Habib; Khedher, Sonia; Boubaker, Hamdi; Beltaief, Kaouthar; Grissa, Mohamed Habib; Trimech, Mohamed Naceur; Kerkeni, Wiem; Chebili, Nawfel; Halila, Imen; Rejeb, Imen; Boukef, Riadh; Rekik, Noureddine; Bouhaja, Bechir; Letaief, Mondher; Nouira, Semir

    2013-05-01

    The New Orleans Criteria and the Canadian CT Head Rule have been developed to decrease the number of normal computed tomography (CT) results in mild head injury. We compare the performance of both decision rules for identifying patients with intracranial traumatic lesions and those who require an urgent neurosurgical intervention after mild head injury. This was an observational cohort study performed between 2008 and 2011 on patients with mild head injury who were aged 10 years or older. We collected prospectively clinical head CT scan findings and outcome. Primary outcome was need for neurosurgical intervention, defined as either death or craniotomy, or the need of intubation within 15 days of the traumatic event. Secondary outcome was the presence of traumatic lesions on head CT scan. New Orleans Criteria and Canadian CT Head Rule decision rules were compared by using sensitivity specifications and positive and negative predictive value. We enrolled 1,582 patients. Neurosurgical intervention was performed in 34 patients (2.1%) and positive CT findings were demonstrated in 218 patients (13.8%). Sensitivity and specificity for need for neurosurgical intervention were 100% (95% confidence interval [CI] 90% to 100%) and 60% (95% CI 44% to 76%) for the Canadian CT Head Rule and 82% (95% CI 69% to 95%) and 26% (95% CI 24% to 28%) for the New Orleans Criteria. Negative predictive values for the above-mentioned clinical decision rules were 100% and 99% and positive values were 5% and 2%, respectively, for the Canadian CT Head Rule and New Orleans Criteria. Sensitivity and specificity for clinical significant head CT findings were 95% (95% CI 92% to 98%) and 65% (95% CI 62% to 68%) for the Canadian CT Head Rule and 86% (95% CI 81% to 91%) and 28% (95% CI 26% to 30%) for the New Orleans Criteria. A similar trend of results was found in the subgroup of patients with a Glasgow Coma Scale score of 15. For patients with mild head injury, the Canadian CT Head Rule had higher

  1. Co-Positivity for Anti-dsDNA, -Nucleosome and -Histone Antibodies in Lupus Nephritis Is Indicative of High Serum Levels and Severe Nephropathy.

    Directory of Open Access Journals (Sweden)

    Jinfeng Yang

    Full Text Available To characterize the significance of correlated autoantibodies in systemic lupus erythematosus (SLE and its complication lupus nephritis (LN in a large cohort of patients.Clinical data were statistically analyzed in 1699 SLE patients with or without nephritis who were diagnosed and treated during 2002-2013 in the northeast region of China. Reactivity to a list of 16 autoantibodies was detected by the serum test Euroline ANA profile (IgG. Serum titers of the anti-nucleosome autoantibodies were measured by ELISA assays. Kidney biopsies were examined by pathologists. Immune complex deposition was identified by immunohistochemistry stain.Simultaneous positivity of anti-dsDNA, -nucleosome and -histone antibodies (3-pos was prevalent in SLE patients with LN compared to Non-renal SLE patients (41% vs 11%, p< 0.001. Significant correlations were found between any two of the above three anti-nucleosome antibodies in LN patients. In comparison to non-3-pos cohorts, 3-pos patients with LN had significantly higher serum levels of the three antibodies and more active disease; was associated with type IV disease; suffered from more severe renal damages; received more intensive treatment and had worse disease outcome. The serum levels of these three autoantibodies in 3-pos LN patients were significantly decreased when they underwent clinical recovery.Simultaneous reactivity to anti-dsDNA, -nucleosome and -histone antibodies by Euroline ANA profile (IgG may indicate severe nephropathy in patients with SLE.

  2. Gallium scans in myasthenia gravis

    International Nuclear Information System (INIS)

    Swick, H.M.; Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether 67 Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67 Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  3. Gallium scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  4. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  5. Positive serum specific IgE has a short half-life in patients with penicillin allergy and reversal does not always indicate tolerance.

    Science.gov (United States)

    Hjortlund, Janni; Mortz, Charlotte Gotthard; Stage, Tore Bjerregaard; Skov, Per Stahl; Dahl, Ronald; Bindslev-Jensen, Carsten

    2014-01-01

    The positive and negative predictive values of specific IgE to penicillins are not well established for penicillin hypersensitivity. One reason may be that serum IgE levels to penicillin diminish over time. The objective in this study was to investigate variations in serum half-life (T½) for specific IgE to penicillins (s-IgE) and to evaluate the outcome of penicillin challenges in patients with previous but not present specific IgE to penicillins. Two subgroups were investigated. All included patients had a history of penicillin allergy with reported symptoms such as urticaria/angioedema or unclassified cutaneous rash. T½ of specific IgE to penicillins was calculated based on sera from 29 patients with repeated measurements of s-IgE. Twenty-two patients with a previous positive s-IgE was followed and challenged with penicillin when IgE had become negative. The T½ for s-IgE varied between the 26 patients with decreasing s-IgE from 1.6 months to 76.4 months and 52% had a T½ of less than a year. The three patients with stable and increasing IgE-values showed T½ approaching infinity A total of 29 challenges with β-lactams were performed. Four different patterns were seen when evaluating the clinical reaction to challenge (positive/negative) and post-challenge boost of s-IgE (yes/no). Eight (36.4%) had negative challenge and negative post-challenge s-IgE, eight (36.4%) negative challenge, but positive post-challenge s-IgE levels. 3 (13.6%) had positive challenge and positive post-challenge s-IgE whereas 3 (13.6%) were challenge positive, but had negative post-challenge s-IgE. Specific IgE to penicillins declines over time stressing the importance of a close time relation between diagnostic work-up and clinical reaction. Reversal of previously positive s-IgE may still be associated with positive penicillin challenges and/or re-boostering of s-IgE to positivity.

  6. 67Ga lung scan

    International Nuclear Information System (INIS)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  7. Environmental scan

    International Nuclear Information System (INIS)

    1988-01-01

    Trends in current affairs and public policy that emerged in 1988 are analyzed to provide a tool for Atomic Energy of Canada's decision makers. This issue provides a general overview of the economic and energy environments; and international review of nuclear policies, equipment orders, and trends that will position Canada and AECL within the global nuclear community; a precis of Canadian public opinion polls on economic, environmental and energy issues; a summary of major trends identifies by Canadian opinion leaders from the public and private sectors; a review of opinions and recommendations of influential Canadian policy institutes; a report on government policies and actions that affect AECL directly or indirectly; an analysis of new coverage by print and electronic media; a review of anti-nuclear organizations; and conclusions and recommendations

  8. Definitive radiotherapy for head-and-neck cancer with radiographically positive retropharyngeal nodes: Incomplete radiographic response does not necessarily indicate failure

    International Nuclear Information System (INIS)

    Liauw, Stanley L.; Mancuso, Anthony A.; Morris, Christopher G. M.S.; Amdur, Robert J.; Mendenhall, William M.

    2006-01-01

    Purpose: Our aim was to report the control rate of radiographically positive retropharyngeal (RP) nodes with radiation therapy (RT) and to correlate posttreatment imaging with clinical outcome. Methods and Materials: Sixteen patients treated with definitive RT for head-and-neck cancer had radiographically positive RP nodes (size >1 cm in largest axial dimension, or presence of focal enhancement, lucency, or calcification), and both pre-RT and post-RT image sets available for review. An additional 21 patients with unconfirmed radiographically positive RP nodes had post-RT imaging, which consisted of computed tomography (CT) at a median of 4 weeks after completing RT. Patients with positive post-RT RP nodes underwent observation with serial imaging. Results: Of 16 patients with pre-RT and post-RT images available for review, 9 (56%) had a radiographic complete response, and of 21 patients with unconfirmed positive RP nodes with post-RT images available for review, 14 (67%) had a radiographic complete response. In all, 14 patients with incomplete response on post-RT imaging experienced control of their disease with no further therapy, and no RP node or neck failures were noted during a median follow-up of 2.8 years. Six patients with positive post-RT RP nodes had serial imaging available for review, and none demonstrated radiographic progression of disease. Conclusions: Radiographic response at 4 weeks may not accurately reflect long-term locoregional control, as RP nodes may continue to resolve over time. The highest index of suspicion should be reserved for patients with progressive changes in size, focal lucency, or focal enhancement on serial imaging after RT

  9. P16INK4a Positive Cells in Human Skin Are Indicative of Local Elastic Fiber Morphology, Facial Wrinkling, and Perceived Age

    DEFF Research Database (Denmark)

    Waaijer, Mariëtte E C; Gunn, David A; Adams, Peter D

    2016-01-01

    Senescent cells are more prevalent in aged human skin compared to young, but evidence that senescent cells are linked to other biomarkers of aging is scarce. We counted cells positive for the tumor suppressor and senescence associated protein p16INK4a in sun-protected upper-inner arm skin biopsies...... wrinkles and a higher perceived age. Participants in the lowest tertile of epidermal p16INK4a counts looked 3 years younger than those in the highest tertile, independently of chronological age and elastic fiber morphology. In conclusion, p16INK4a positive cell numbers in sun-protected human arm skin...

  10. Acid sphingomyelinase activity as an indicator of the cell stress in HPV-positive and HPV-negative head and neck squamous cell carcinoma.

    Science.gov (United States)

    Gerle, Mirko; Medina, Tuula Peñate; Gülses, Aydin; Chu, Hanwen; Naujokat, Hendrik; Wiltfang, Jörg; Açil, Yahya

    2018-03-21

    Human papillomavirus (HPV) infection, especially HPV-16 and HPV-18, has been increasingly associated with head and neck squamous cell carcinoma. The treatment of HPV-positive squamous cell carcinoma has a better response to both radiotherapy and chemotherapy and presents a better prognosis for the patient. Defining the underlying mechanism of the difference might help in developing future treatment options and could be an important factor in personal therapy planning. Endogenously secreted acid sphingomyelinase (ASMase) levels in the cellular stress caused by irradiation and cisplatin were investigated. MTT assay was performed to evaluate the viability of the treated cells. Keratinocytes were used to evaluate the effects of radiation on normal tissues. Irradiation caused a dose-dependent increase in ASMase activity in both SCC9 HPV-negative, and UDSCC2 HPV-positive cells. ASMase activity in UDSCC2 cells was significantly higher than that in SCC9 cells. UDSCC cells were more sensitive to cisplatin treatment than SCC cells, and the dose-response in the activity was observed in long-time treatments when high doses of cisplatin were used. The results of the current study have clearly showed that HPV positivity should be considered as one of the determinative factors which should be considered when tumor treatments are planned. However, further studies are needed to determine the differences in cellular responses and pathways among HPV-negative and HPV-positive cells.

  11. A Focus on Implementation of Positive Behavioral Interventions and Supports (PBIS) in High Schools: Associations with Bullying and Other Indicators of School Disorder

    Science.gov (United States)

    Bradshaw, Catherine P.; Pas, Elise T.; Debnam, Katrina J.; Johnson, Sarah Lindstrom

    2015-01-01

    There is growing interest in the use of a multi-tiered system of supports framework to address issues related to school climate and bullying. Positive Behavioral Interventions and Supports (PBIS) is one such model that has received considerable attention; however, nearly all of the extant literature has focused on elementary and middle schools,…

  12. Medial Position and Counterclockwise Rotation of the Parietal Scalp Hair-Whorl as a Possible Indicator for Non-Right-Handedness

    Directory of Open Access Journals (Sweden)

    Heinrich Schmidt

    2008-01-01

    Full Text Available The objective of our study was to assess the association between position and swirling direction of the parietal whorl (PW and handedness. In 519 patients of a pediatric practice, PWs were located and the swirling direction determined. Of those patients, handedness could be specified in 217. The right-sided PW (n = 347; 70.8% and the clockwise (CW swirling type (n = 411; 83.9% of all participants were predominant in children with one PW. Non-right-handedness (NRH was found in 40 (18.4%. Medial position of the whorl per se increases the chance for NRH, indifferent of the swirling direction. In patients with counterclockwise (CCW swirling, the chance of NRH increased 3.5-fold for the right-sided, 5.4-fold for the left-sided, and 12.9-fold for the medial-positioned whorl. We conclude that NRH is associated with the position (medial! and the swirling direction (CCW! of the PW.

  13. Angiotensin-I-converting enzyme and gallium scan in noninvasive evaluation of sarcoidosis

    International Nuclear Information System (INIS)

    Nosal, A.; Schleissner, L.A.; Mishkin, F.S.; Lieberman, J.

    1979-01-01

    Angiotensin-converting enzyme assays and gallium-scan results were obtained from 27 patients with biopsy-proven, clinically active sarcoidosis. Twenty-three of these patients had elevated converting enzyme levels, and 22 had positive gallium-scan results. Three of four patients with normal or borderline-elevated levels of angiotensin-converting enzyme also had positive gallium-scan results. Of 156 nonsarcoid patients (pulmonary and other diseases), 27 were found to have elevated serum converting enzyme levels, and 25 of these had negative gallium-scan results. These results indicate that the combination of an assay of angiotensin-converting enzyme and gallium scan increases diagnostic specificity from 83% to 99% without sacrificing sensitivity. It was concluded that the concurrent use of angiotensin-converting enzyme assay and gallium scan is of value in the diagnosis of sarcoidosis

  14. Angiotensin-I-converting enzyme and gallium scan in noninvasive evaluation of sarcoidosis

    Energy Technology Data Exchange (ETDEWEB)

    Nosal, A. (Harbor General Hospital, Torrance, CA); Schleissner, L.A.; Mishkin, F.S.; Lieberman, J.

    1979-03-01

    Angiotensin-converting enzyme assays and gallium-scan results were obtained from 27 patients with biopsy-proven, clinically active sarcoidosis. Twenty-three of these patients had elevated converting enzyme levels, and 22 had positive gallium-scan results. Three of four patients with normal or borderline-elevated levels of angiotensin-converting enzyme also had positive gallium-scan results. Of 156 nonsarcoid patients (pulmonary and other diseases), 27 were found to have elevated serum converting enzyme levels, and 25 of these had negative gallium-scan results. These results indicate that the combination of an assay of angiotensin-converting enzyme and gallium scan increases diagnostic specificity from 83% to 99% without sacrificing sensitivity. It was concluded that the concurrent use of angiotensin-converting enzyme assay and gallium scan is of value in the diagnosis of sarcoidosis.

  15. Non-response to a life course socioeconomic position indicator in surveillance: comparison of telephone and face-to-face modes

    OpenAIRE

    Chittleborough, Catherine R; Taylor, Anne W; Baum, Fran E; Hiller, Janet E

    2008-01-01

    Abstract Background Measurement of socioeconomic position (SEP) over the life course in population health surveillance systems is important for examining differences in health and illness between different population groups and for monitoring the impact of policies and interventions aimed at reducing health inequities and intergenerational disadvantage over time. While face-to-face surveys are considered the gold standard of interviewing techniques, computer-assisted telephone interviewing is...

  16. Scanning behavior in echolocating common pipistrelle bats (Pipistrellus pipistrellus.

    Directory of Open Access Journals (Sweden)

    Anna-Maria Seibert

    Full Text Available Echolocating bats construct an auditory world sequentially by analyzing successive pulse-echo pairs. Many other mammals rely upon a visual world, acquired by sequential foveal fixations connected by visual gaze saccades. We investigated the scanning behavior of bats and compared it to visual scanning. We assumed that each pulse-echo pair evaluation corresponds to a foveal fixation and that sonar beam movements between pulses can be seen as acoustic gaze saccades. We used a two-dimensional 16 microphone array to determine the sonar beam direction of succeeding pulses and to characterize the three dimensional scanning behavior in the common pipistrelle bat (Pipistrellus pipistrellus flying in the field. We also used variations of signal amplitude of single microphone recordings as indicator for scanning behavior in open space. We analyzed 33 flight sequences containing more than 700 echolocation calls to determine bat positions, source levels, and beam aiming. When searching for prey and orienting in space, bats moved their sonar beam in all directions, often alternately back and forth. They also produced sequences with irregular or no scanning movements. When approaching the array, the scanning movements were much smaller and the beam was moved over the array in small steps. Differences in the scanning pattern at various recording sites indicated that the scanning behavior depended on the echolocation task that was being performed. The scanning angles varied over a wide range and were often larger than the maximum angle measurable by our array. We found that echolocating bats use a "saccade and fixate" strategy similar to vision. Through the use of scanning movements, bats are capable of finding and exploring targets in a wide search cone centered along flight direction.

  17. Indications and limitations of bariatric intervention in severely obese children and adolescents with and without nonalcoholic steatohepatitis: ESPGHAN Hepatology Committee Position Statement.

    Science.gov (United States)

    Nobili, Valerio; Vajro, Pietro; Dezsofi, Antal; Fischler, Bjorn; Hadzic, Nedim; Jahnel, Joerg; Lamireau, Thierry; McKiernan, Patrick; McLin, Valerie; Socha, Piotr; Tizzard, Sarah; Baumann, Ulrich

    2015-04-01

    Morbid obesity is strongly associated with nonalcoholic fatty liver disease (NAFLD), which is one of the most common causes of chronic liver disease worldwide. The present best treatment for NAFLD and nonalcoholic steatohepatitis (NASH) is weight reduction through lifestyle modification. Because of frustrating inefficiency of such a therapeutic approach, bariatric surgery is increasingly performed in adolescents as an alternative option for weight reduction. Standards of care and consensus for indications are, however, scarce. We explore the indications and limitations of bariatric surgery in children with severe obesity with and without NASH and aim to provide guidance for the exceptional indications for adolescents with extreme obesity with major comorbidity that may benefit from these controversial interventions. Present evidence suggests that bariatric surgery can decrease the grade of steatosis, hepatic inflammation, and fibrosis in NASH. Uncomplicated NAFLD is not an indication for bariatric surgery. Roux-en-Y gastric bypass is considered a safe and effective option for adolescents with extreme obesity, as long as an appropriate long-term follow-up is provided. Laparoscopic adjustable gastric banding has not been approved by the Food and Drug Administration for use in adolescents and therefore should be considered investigational. Finally, sleeve gastrectomy and other types of weight loss surgery that have grown increasingly common in adults, still need to be considered investigational. Temporary devices may be increasingly being used in pediatrics; however, future studies, including a long-term risk analysis of patients who undergo surgery, are much needed to clarify the exact indications for bariatric surgery in adolescents.

  18. Scan analysis in myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J [Landesunfallkrankenhaus, Feldkirch (Austria). Inst. fuer Strahlenmedizin

    1976-08-01

    Myocardial scans with sup(99m)Tc-labelled phosphates are reported to be useful in the diagnosis of acute myocardial infarction. A retrospective survey of 205 patients referred for sup(99m)Tc-phophate bone scanning and with no evidence of recent heart disease revealed an occurrence of 10% of false positive images, that is to say, uptake of phosphate in non-infarcted mayocardium. These striking findings stress the need for critical assessment of the usefulness of this diagnostic technique.

  19. Differential ultrasonic indices of separation distress in the presence and absence of maternal cues in infant rats bred for high and low positive social affect.

    Science.gov (United States)

    Iacobucci, Paolo; Colonnello, Valentina; Fuchs, Thomas; D'Antuono, Laura; Panksepp, Jaak

    2013-10-01

    Preclinical models of human mood disorders commonly focus on the study of negative affectivity, without comparably stressing the role of positive affects and their ability to promote resilient coping styles. We evaluated the role of background constitutional affect of rats by studying the separation and reunion responses of infants from low and high positive affect genetic lines (i.e., differentially selected for High and Low 50 kHz ultrasonic vocalisations (USVs). Infants from Low and High 50 kHz USV breeding lines were isolated from mothers and exposed to either social (familiar or unfamiliar bedding) or neutral (clean bedding) odour cues between two short isolation periods, and tested in homeothermic and hypothermic ambient temperatures. Negative affect was estimated by monitoring separation distress calls (35-45 kHz USVs). Low Line pups called at higher rates than High Line, and their rates were stable regardless of odour cue. In contrast, High Line pups increased vocalisations during the second compared with the first isolation periods and during exposure to both familiar and unfamiliar odour cues, but not to neutral odour. Furthermore, the greatest increase in USV emission was seen in the second isolation period following exposure to the unfamiliar odour. However, both lines showed comparable elevated distress USVs to the thermal stressor. High Line animals, selected for a positive affective phenotype (50 kHz USVs), exhibited reduced separation anxiety responses in infancy, making this a promising animal model for the role of constitutional affective states in emotional responsivity and potential resilience against emotional disorders.

  20. Gallium scan in recurrent Hodgkin's disease in children

    International Nuclear Information System (INIS)

    Yeh, S.D.; Benua, R.S.; Tan, C.T.

    1979-01-01

    In 18 of 88 children with biopsy proven and previously untreated Hodgkin's disease, recurrence developed during a period from four to 53 months after therapy (median period, 22 months). In 16 patients in whom gallium scans were performed, 21 positive gallium scans were obtained during 26 episodes of recurrence. Abnormalities were noted in half of them during a period from one to 10 months prior to physical, laboratory, radiographic or histologic confirmation of recurrence (median period about 5 months). We have concluded that the gallium scan is very useful in initial workup and is sensitive in detecting early recurrence in children with Hodgkin's disease. Such scans are indicated when there is clinical suspicion of recurrence, when other modalities are unavailable or when the results of other studies are equivocal

  1. Prospective analysis of in vivo landmark point-based MRI geometric distortion in head and neck cancer patients scanned in immobilized radiation treatment position: Results of a prospective quality assurance protocol

    Directory of Open Access Journals (Sweden)

    Abdallah S.R. Mohamed

    2017-12-01

    Full Text Available Purpose: Uncertainties related to geometric distortion are a major obstacle for effectively utilizing MRI in radiation oncology. We aim to quantify the geometric distortion in patient images by comparing their in-treatment position MRIs with the corresponding planning CTs, using CT as the non-distorted gold standard. Methods: Twenty-one head and neck cancer patients were imaged with MRI as part of a prospective Institutional Review Board approved study. MR images were acquired with a T2 SE sequence (0.5 × 0.5 × 2.5 mm voxel size in the same immobilization position as in the CTs. MRI to CT rigid registration was then done and geometric distortion comparison was assessed by measuring the corresponding anatomical landmarks on both the MRI and the CT images. Several landmark measurements were obtained including; skin to skin (STS, bone to bone, and soft tissue to soft tissue at specific levels in horizontal and vertical planes of both scans. Inter-observer variability was assessed and interclass correlation (ICC was calculated. Results: A total of 430 landmark measurements were obtained. The median distortion for all landmarks in all scans was 1.06 mm (IQR 0.6–1.98. For each patient 48% of the measurements were done in the right-left direction and 52% were done in the anteroposterior direction. The measured geometric distortion was not statistically different in the right-left direction compared to the anteroposterior direction (1.5 ± 1.6 vs. 1.6 ± 1.7 mm, respectively, p = 0.4. The magnitude of distortion was higher in the STS peripheral landmarks compared to the more central landmarks (2.0 ± 1.9 vs. 1.2 ± 1.3 mm, p < 0.0001. The mean distortion measured by observer one was not significantly different compared to observer 2, 3, and 4 (1.05, 1.23, 1.06 and 1.05 mm, respectively, p = 0.4 with ICC = 0.84. Conclusion: MRI geometric distortions were

  2. Providing straw to allow exploratory behaviour in a pig experimental system does not modify putative indicators of positive welfare: peripheral oxytocin and serotonin.

    Science.gov (United States)

    Marcet Rius, M; Cozzi, A; Bienboire-Frosini, C; Teruel, E; Chabaud, C; Monneret, P; Leclercq, J; Lafont-Lecuelle, C; Pageat, P

    2018-01-22

    Numerous studies have shown that providing straw to pigs can reduce undesirable behaviours such as aggression, tail biting and stereotypy. The measurement of various neuromodulators can be helpful in assessing the development of positive behaviours and overall animal welfare. The oxytocin release is frequently linked to positive emotions and positive welfare. It has been suggested that oxytocin modulates the serotoninergic system. This study aims to investigate the potential effect of straw provision in pigs on peripheral levels of oxytocin and serotonin. In total, 18 mini-pigs were involved in an exploratory study conducted in two parallel groups, Enriched (n=10) and Control (n=8) groups. Pigs were divided by group and housed in pens of two individuals. Straw was provided continuously only in Enriched group and renewed each day for 2 weeks. Two blood samples were drawn from each animal 5 to 10 min before providing the straw, and 15 min after providing straw, during the 1st week, to analyse peripheral changes in oxytocin and serotonin before and after straw provision, and determine the existence of a putative short-term effect. The same procedure was carried out for Control group, without straw provision. Long-term effects of straw provision were also examined using blood samples drawn at the same hour from each animal in the 2nd and 3rd weeks. During this time, animals had the permanent possibility to explore the straw in Enriched group but not in Control group. At the end of each week, one animal-keeper completed two visual analogue scales for each mini-pig regarding the difficulty/ease to work with and handle it and its trust in humans. Results showed peripheral oxytocin increases in both groups after 2 weeks (P=0.02). Results did not demonstrate any effect of providing straw to allow exploratory behaviour on peripheral serotonin. Other results were not significant. This preliminary study explored the relationship between peripheral oxytocin and serotonin and

  3. Alcohol Use and Associations With Biological Markers and Self-Reported Indicators of Unprotected Sex in Human Immunodeficiency Virus-Positive Female Sex Workers in Mombasa, Kenya.

    Science.gov (United States)

    White, Darcy; Wilson, Kate S; Masese, Linnet N; Wanje, George; Jaoko, Walter; Mandaliya, Kishorchandra; Richardson, Barbra A; Kinuthia, John; Simoni, Jane M; McClelland, R Scott

    2016-10-01

    Studies of alcohol use and sexual behavior in African populations have primarily been cross-sectional, used nonvalidated measures of alcohol use, or relied on self-reported sexual risk endpoints. Few have focused on human immunodeficiency virus (HIV)-positive women. Longitudinal data were collected from a cohort of HIV-positive Kenyan female sex workers. At enrollment and annual visits, participants were asked about past-year alcohol use using the Alcohol Use Disorders Identification Test (AUDIT). The primary endpoint was detection of prostate-specific antigen (PSA) in vaginal secretions at quarterly examinations. Associations between hazardous/harmful alcohol use (AUDIT score ≥7), PSA detection, and secondary measures of sexual risk were evaluated using generalized estimating equations with a log binomial regression model. A total of 405 women contributed 2750 vaginal samples over 606 person-years of follow-up. Hazardous/harmful alcohol use was reported at 16.6% of AUDIT assessments and was associated with higher risk of PSA detection (relative risk 1.50; 95% confidence interval, 1.11-2.01) relative to no alcohol use. This association was attenuated and no longer statistically significant, after adjusting for age, work venue, intimate partner violence, depression, and partnership status (adjusted relative risk, 1.13; 95% confidence interval, 0.82-1.56). In exploratory analyses, alcohol use was associated with self-report of unprotected sex and with sexually transmitted infection acquisition. Although hazardous/harmful alcohol use was not associated with detection of PSA in adjusted analysis, associations with secondary outcomes suggest that alcohol use is at least a marker of sexual risk behavior.

  4. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  5. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  6. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients.

    Science.gov (United States)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong

    2013-12-01

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  7. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  8. An interchangeable scanning Hall probe/scanning SQUID microscope

    International Nuclear Information System (INIS)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K

  9. An interchangeable scanning Hall probe/scanning SQUID microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Chen, Tse-Jun; Wang, M. J. [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan (China); Ling, D. C. [Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan (China); Chi, C. C.; Chen, Jeng-Chung [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  10. Absent/weak CD44 intensity and positive human papillomavirus (HPV) status in oropharyngeal squamous cell carcinoma indicates a very high survival

    International Nuclear Information System (INIS)

    Näsman, Anders; Nordfors, Cecilia; Grün, Nathalie; Munck-Wikland, Eva; Ramqvist, Torbjörn; Marklund, Linda; Lindquist, David; Dalianis, Tina

    2013-01-01

    Patients with human papillomavirus DNA positive (HPV DNA +) oropharyngeal squamous cell carcinoma (OSCC) have better clinical outcome than those with HPV DNA negative (HPV DNA −) OSCC upon intensive oncological treatment. All HPV DNA + OSCC patients may not require intensive treatment, however, but before potentially deintensifying treatment, additional predictive markers are needed. Here, we examined HPV, p16 INK4a , and CD44 in OSCC in correlation to clinical outcome. Pretreatment tumors from 290 OSCC patients, the majority not receiving chemotherapy, were analyzed for HPV DNA by Luminex and for p16 INK4a and CD44 by immunohistochemistry. 225/290 (78%) tumors were HPV DNA + and 211/290 (73%) overexpressed p16 INK4a , which correlated to presence of HPV (P < 0.0001). Presence of HPV DNA, absent/weak CD44 intensity staining correlated to favorable 3-year disease-free survival (DFS) and overall survival (OS) by univariate and multivariate analysis, and likewise for p16 INK4a by univariate analysis. Upon stratification for HPV, HPV DNA + OSCC with absent/weak CD44 intensity presented the significantly best 3-year DFS and OS, with >95% 3-year DFS and OS. Furthermore, in HPV DNA + OSCC, p16 INK4a + overexpression correlated to a favorable 3-year OS. In conclusion, patients with HPV DNA + and absent/weak CD44 intensity OSCC presented the best survival and this marker combination could possibly be used for selecting patients for tailored deintensified treatment in prospective clinical trials. Absence of/weak CD44 or presence of human papillomavirus (HPV) DNA was shown as a favorable prognostic factors in tonsillar and tongue base cancer. Moreover, patients with the combination of absence of/weak CD44 and presence of HPV DNA presented a very favorable outcome. Therefore, we suggest that this marker combination could potentially be used to single out patients with a high survival that could benefit from a de-escalated oncological treatment

  11. Global Positioning System Derived Performance Measures Are Responsive Indicators of Physical Activity, Disease and the Success of Clinical Treatments in Domestic Dogs

    Science.gov (United States)

    Bruno, Elizabeth A.; Guthrie, James W.; Ellwood, Stephen A.; Mellanby, Richard J.; Clements, Dylan N.

    2015-01-01

    Objective To assess the use of Global Positioning System receiver (GPS) derived performance measures for differentiating between: 1) different outdoor activities in healthy dogs; 2) healthy dogs and those with osteoarthritis; 3) osteoarthritic dogs before and after treatment with non-steroidal anti-inflammatory analgesia. Design Prospective study. Animals Ten healthy dogs and seven dogs with osteoarthritis of the elbow joint (OA dogs). Procedure Healthy dogs were walked on a standard route on-lead, off-lead and subjected to playing activity (chasing a ball) whilst wearing a GPS collar. Each dog was walked for five consecutive days. Dogs with OA were subjected to a single off-lead walk whilst wearing a GPS collar, and then administered oral Carprofen analgesia daily for two weeks. OA dogs were then subjected to the same walk, again wearing a GPS collar. Results GPS derived measures of physical performance could differentiate between on-lead activity, off-lead activity and playing activity in healthy dogs, and between healthy dogs and OA dogs. Variation in the performance measures analysed was greater between individual dogs than for individual dogs on different days. Performance measures could differentiate healthy dogs from OA dogs. OA Dogs treated with Carprofen analgesia showed improvements in their physical performance, which returned to values indistinguishable from those of healthy dogs on nearly all the measures assessed. Conclusions and Clinical Relevance GPS derived measures of physical performance in dogs are objective, easy to quantify, and can be used to gauge the effects of disease and success of clinical treatments. Specific stimuli can be used to modulate physical performance beyond the self-governed boundaries that dogs will naturally express when allowed to exercise freely without stimulation. PMID:25692761

  12. Global positioning system derived performance measures are responsive indicators of physical activity, disease and the success of clinical treatments in domestic dogs.

    Directory of Open Access Journals (Sweden)

    Elizabeth A Bruno

    Full Text Available To assess the use of Global Positioning System receiver (GPS derived performance measures for differentiating between: 1 different outdoor activities in healthy dogs; 2 healthy dogs and those with osteoarthritis; 3 osteoarthritic dogs before and after treatment with non-steroidal anti-inflammatory analgesia.Prospective study.Ten healthy dogs and seven dogs with osteoarthritis of the elbow joint (OA dogs.Healthy dogs were walked on a standard route on-lead, off-lead and subjected to playing activity (chasing a ball whilst wearing a GPS collar. Each dog was walked for five consecutive days. Dogs with OA were subjected to a single off-lead walk whilst wearing a GPS collar, and then administered oral Carprofen analgesia daily for two weeks. OA dogs were then subjected to the same walk, again wearing a GPS collar.GPS derived measures of physical performance could differentiate between on-lead activity, off-lead activity and playing activity in healthy dogs, and between healthy dogs and OA dogs. Variation in the performance measures analysed was greater between individual dogs than for individual dogs on different days. Performance measures could differentiate healthy dogs from OA dogs. OA Dogs treated with Carprofen analgesia showed improvements in their physical performance, which returned to values indistinguishable from those of healthy dogs on nearly all the measures assessed.GPS derived measures of physical performance in dogs are objective, easy to quantify, and can be used to gauge the effects of disease and success of clinical treatments. Specific stimuli can be used to modulate physical performance beyond the self-governed boundaries that dogs will naturally express when allowed to exercise freely without stimulation.

  13. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients

    International Nuclear Information System (INIS)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong

    2013-01-01

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  14. Image analysis of the eruptive positions of third molars and adjacent second molars as indicators of age evaluation in Thai patients

    Energy Technology Data Exchange (ETDEWEB)

    Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong [Chiang Mai University, Chiang Mai (Thailand)

    2013-12-15

    This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.

  15. The presence of some humoral immunologic indicators and clinical manifestations in cryoglobulin positive heroin addicts without evidence of hepatitis virus infection

    Directory of Open Access Journals (Sweden)

    Simonovska Natasha

    2015-01-01

    Full Text Available Introduction. Cryoglobulins are single or mixed immunoglobulins that are subject to reversible precipitation at low temperatures. Objective. The aims of this paper were: 1. Comparison of cryoglobulin positive (CP, cryoglobulin negative (CN heroin addicts and the control group (CG in terms of serum immunoglobulins IgG, IgA and IgM and complement components C3 and C4; 2. Comparison of CP and CN heroin addicts in terms of rheumatoid factor (RF and circulating immune complexes (CIC; 3. Assessment of clinical manifestations in CP heroin addicts. Methods. This is a comparative study of cases (outpatients treated at the University Clinic of Toxicology in Skopje over 3.5 years, from January 2009 to June 2012. In this study 140 heroin addicts without HbsAg were examined, seronegative for HCV and HIV infections. They were divided into 2 groups: 70 CP and 70 CN heroin addicts. A previously designed self-administered questionnaire was used as a data source on participants. All heroin addicts underwent the following analyses: urea and creatinine in serum; creatinine in urine; proteinuria; 24-hour proteinuria; IgM, IgG, IgA, C3, C4 ; RF; CIC; creatinine clearance; ECG; toxicological analyses for opioids in a urine sample; cryoglobulins. In addition to these 2 groups, IgG, IgA, IgM, C3 and C4 were also examined in 70 healthy subjects (CG. Results. The study showed that there was no statistically significant difference between CP, CN heroin addicts and CG regarding the concentration of IgA, IgG, IgM, C3 and C4, and between CP and CN regarding the concentration of CIC. There was significant difference between CP and CN regarding the concentration of RF. The following conditions were significantly more frequently manifested in CP than in CN heroin addicts: arthralgia, Raynaud’s phenomenon, respiratory difficulties, neurological disorders, manifested skin changes, hematuria, 24-hour proteinuria levels, and decreased renal clearance. Conclusion. There were no

  16. Functional characterization of a Nudix hydrolase AtNUDX8 upon pathogen attack indicates a positive role in plant immune responses.

    Directory of Open Access Journals (Sweden)

    Jose Pedro Fonseca

    plant immunity as a positive regulator of defense in Arabidopsis.

  17. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  18. Maatregelen ter vermindering van fijnstofemissie uit de pluimveehouderij: indicatieve evaluatie van positieve ionisatie van uitgaande ventilatielucht = Measures to reduce fine dust emission from poultry: indicative evaluation of positive ionization of exhaust air

    NARCIS (Netherlands)

    Winkel, A.; Ogink, N.W.M.

    2010-01-01

    In this study a positive ionization system (end of pipe technique) is indicatively evaluated for its potential to remove fine dust from exhaust air of poultry houses. From this study it is concluded that the system can be effective and applicable.

  19. Antimicrobial susceptibility of coagulase-positive and coagulase-variable Staphylococci from various indications of swine, dogs and cats as determined in the BfT-GermVet monitoring program 2004-2006.

    Science.gov (United States)

    Schwarz, Stefan; Alesík, Eva; Werckenthin, Christiane; Grobbel, Mirjam; Lübke-Becker, Antina; Wieler, Lothar H; Wallmann, Jürgen

    2007-01-01

    A total of 248 coagulase-positive and coagulase-variable staphylococci from two indications of swine (infections of the urinary/genital tract including strains from the mastitis metritis agalactia syndrome as well as infections of the skin) as well as two indications of dogs/cats (respiratory tract infections and infections of skin/ear/mouth) were investigated for their susceptibility to numerous antimicrobial agents. Regardless of the animal origin and indication, the most frequently detected resistance properties were resistances against penicillin G (53-77%) and ampicillin (42-75%), tetracycline (33-52%) as well as erythromycin (13-27%). Oxacillin-resistant staphylococci were rarely detected.

  20. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  1. Scanning Tunneling Microscope For Use In Vacuum

    Science.gov (United States)

    Abel, Phillip B.

    1993-01-01

    Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

  2. The utility of bone scans in rheumatology

    International Nuclear Information System (INIS)

    Duncan, I.; Dorai-Raj, A.; Khoo, K.; Tymans, K.; Brook, A.

    1997-01-01

    Full text: Introduction: Bone scans are the commonest diagnostic imaging services requested by Australian rheumatologists. Medicare figures suggest that an average rheumatologist orders about $50 000 (AUS) of bone scans annually. Aims: To ascertain the reasons why rheumatologists request bone scans and how it affects their patient management. Methods: A two-part prospective survey was administered before and after every bone scan ordered by four rheumatologists over a six-month period in 1996. Results: A total of 136 bone scans were requested (66.2% whole body; 33.8% regional; 6% SPECT). The primary indications for scanning were (1) to confirm a clinical diagnosis (38%); (2) to exclude a diagnosis (34%); (3) to localize site of pain (17%); and (4) to assist in management (6%). The common diseases that rheumatologists were attempting to confirm/exclude with bone scanning were inflammatory arthritis, malignancy, and fracture. However, the commonest provisional and final diagnosis was soft tissue rheumatism (18%) followed by inflammatory arthritis (15%) and osteoarthritis (11%). In 24% of patients with a provisional diagnosis of soft tissue rheumatism the diagnosis was changed by the bone scan. The scan was successful in excluding a diagnosis in 88 per cent where this was the primary indication for the test. It was successful in confirming a diagnosis in 79 per cent where this was the primary indication. In 32 per cent the bone scan altered the clinical diagnosis and in 43 per cent it altered management. The bone scan result prevented further investigations in 60 per cent. Conclusions: The commonest pre-scan and post-scan diagnosis is soft tissue rheumatism. Rheumatologists predominantly request bone scanning to confirm or exclude their clinical suspicion of inflammatory arthritis, malignancy, and fracture. Bone scans were successful in achieving these objectives in at least 79 per cent of cases

  3. Efficacy of brain scanning in epilepsy of late onset

    International Nuclear Information System (INIS)

    Jain, A.N.; Ramanathan, P.; Ganatra, R.D.

    1978-01-01

    Brain scans of 513 patients with epilepsy of late onset were analysed with reference to the patient's age and sex and to the nature of convulsion. Only 17 of them showed an abnormal concentration of radionuclide indicating a space-occupying lesion in the brain. The findings of those patients who had positive brain scans were correlated with EEG findings. It was found that the incidence of epilepsy of late onset is almost 3 times higher in males than in females and that the age cannot be considered as a criterion for screening the patients for brain scan investigation as far as epilepsy of late onset is concerned. In the authors' opinion, the incidence of 3.3% is not too low. A positive brain scan finding calls for further investigation and helps in deciding the management and further line of treatment of the patients. Moreover, a normal scan rules out the presence of a space-occupying lesion and helps as a screening procedure. (orig.) 891 MG [de

  4. The utility of repeat sestamibi scans in patients with primary hyperparathyroidism after an initial negative scan.

    Science.gov (United States)

    Krishnamurthy, Vikram D; Sound, Sara; Okoh, Alexis K; Yazici, Pinar; Yigitbas, Hakan; Neumann, Donald; Doshi, Krupa; Berber, Eren

    2017-06-01

    We analyzed the utility of repeated sestambi scans in patients with primary hyperparathyroidism and its effects on operative referral. We carried out a retrospective review of patients with primary hyperparathyroidism who underwent repeated sestambi scans exclusively within our health system between 1996-2015. Patient demographic, presentation, laboratory, imaging, operative, and pathologic data were reviewed. Univariate analysis with JMP Pro v12 was used to identify factors associated with conversion from an initial negative to a subsequent positive scan. After exclusion criteria (including reoperations), we identified 49 patients in whom 59% (n = 29) of subsequent scans remained negative and 41% (n = 20) converted to positive. Factors associated with an initial negative to a subsequent positive scan included classic presentation and second scans with iodine subtraction (P = .04). Nonsurgeons were less likely to order an iodine-subtraction scan (P < .05). Fewer patients with negative imaging were referred to surgery (33% vs 100%, P = .005), and median time to operation after the first negative scan was 25 months (range 1.4-119). Surgeon-performed ultrasonography had greater sensitivity and positive predictive value than repeated sestamibi scans. Negative sestambi scans decreased and delayed operative referral. Consequently, we identified several process improvement initiatives, including education regarding superior institutional imaging. Combining all findings, we created an algorithm for evaluating patients with primary hyperparathyroidism after initially negative sestamibi scans, which incorporates surgeon-performed ultrasonography. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

    Science.gov (United States)

    Fang, Ning; Sun, Wei

    2015-04-21

    A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

  6. Radiopharmaceutical scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  7. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Scan and Uptake Thyroid scan and uptake uses small amounts of radioactive materials called radiotracers, a special ... is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine ...

  8. Nuclear Heart Scan

    Science.gov (United States)

    ... Home / Nuclear Heart Scan Nuclear Heart Scan Also known as Nuclear Stress Test , ... Learn More Connect With Us Contact Us Directly Policies Privacy Policy Freedom of Information Act (FOIA) Accessibility ...

  9. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  10. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  11. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  12. Brain cortical structural differences between non-central nervous system cancer patients treated with and without chemotherapy compared to non-cancer controls: a cross-sectional pilot MRI study using clinically indicated scans

    Science.gov (United States)

    Shiroishi, Mark S.; Gupta, Vikash; Bigjahan, Bavrina; Cen, Steven Y.; Rashid, Faisal; Hwang, Darryl H.; Lerner, Alexander; Boyko, Orest B.; Liu, Chia-Shang Jason; Law, Meng; Thompson, Paul M.; Jahanshad, Neda

    2017-11-01

    Background: Increases in cancer survival have made understanding the basis of cancer-related cognitive impairment (CRCI) more important. CRCI neuroimaging studies have traditionally used dedicated research brain MRIs in breast cancer survivors with small sample sizes; little is known about other non-CNS cancers. However, there is a wealth of unused data from clinically-indicated MRIs that could be used to study CRCI. Objective: Evaluate brain cortical structural differences in those with non-CNS cancers using clinically-indicated MRIs. Design: Cross-sectional Patients: Adult non-CNS cancer and non-cancer control (C) patients who underwent clinically-indicated MRIs. Methods: Brain cortical surface area and thickness were measured using 3D T1-weighted images. An age-adjusted linear regression model was used and the Benjamini and Hochberg false discovery rate (FDR) corrected for multiple comparisons. Group comparisons were: cancer cases with chemotherapy (Ch+), cancer cases without chemotherapy (Ch-) and subgroup of lung cancer cases with and without chemotherapy vs C. Results: Sixty-four subjects were analyzed: 22 Ch+, 23 Ch- and 19 C patients. Subgroup analysis of 16 LCa was also performed. Statistically significant decreases in either cortical surface area or thickness were found in multiple ROIs primarily within the frontal and temporal lobes for all comparisons. Limitations: Several limitations were apparent including a small sample size that precluded adjustment for other covariates. Conclusions: Our preliminary results suggest that various types of non-CNS cancers, both with and without chemotherapy, may result in brain structural abnormalities. Also, there is a wealth of untapped clinical MRIs that could be used for future CRCI studies.

  13. Scanning device for scintigraphy

    International Nuclear Information System (INIS)

    Casale, R.

    1975-01-01

    A device is described for the scintigraphic scanning according to a horizontal plane, comprising: (a) A support provided with two guides horizontally and longitudinally located, one of which is located in the upper part of the support, while the second guide is located in the lower part of the support; (b) A carriage, movable with respect to the support along the two guides, provided in its upper part, projecting above the support, with rolling means suitable to support and to cause to slide along its axis a support rod for the first detector, horizontally and transversely located, said carriage being further provided in its lower part with a recess with possible rolling means suitable to support and to cause to slide along its axis a second support rod for the second detector, said second rod being located parallel to the first rod and below it; (c) One or two support rods for the detectors, the first of said rods being supported above the support in a sliding way along its axis, by the rolling means located in the upper part of the carriage, and the second rod if present is supported slidingly along its axis by the possible rolling means contained in the suitable recess which is provided in the lower part of the carriage, and (d) A vertical shaft supported by said carriage on which is mounted a toothed wheel for each rod, each toothed wheel engaging a positive drive belt or the like, which is connected to each said rod so that rotation of the shaft determines the simultaneous displacement of the two rods along their axes; and single motor means for driving said shaft during a scanning operation. (U.S.)

  14. Mouse manipulation through single-switch scanning.

    Science.gov (United States)

    Blackstien-Adler, Susie; Shein, Fraser; Quintal, Janet; Birch, Shae; Weiss, Patrice L Tamar

    2004-01-01

    Given the current extensive reliance on the graphical user interface, independent access to computer software requires that users be able to manipulate a pointing device of some type (e.g., mouse, trackball) or be able to emulate a mouse by some other means (e.g., scanning). The purpose of the present study was to identify one or more optimal single-switch scanning mouse emulation strategies. Four alternative scanning strategies (continuous Cartesian, discrete Cartesian, rotational, and hybrid quadrant/continuous Cartesian) were selected for testing based on current market availability as well as on theoretical considerations of their potential speed and accuracy. Each strategy was evaluated using a repeated measures study design by means of a test program that permitted mouse emulation via any one of four scanning strategies in a motivating environment; response speed and accuracy could be automatically recorded and considered in view of the motor, cognitive, and perceptual demands of each scanning strategy. Ten individuals whose disabilities required them to operate a computer via single-switch scanning participated in the study. Results indicated that Cartesian scanning was the preferred and most effective scanning strategy. There were no significant differences between results from the Continuous Cartesian and Discrete Cartesian scanning strategies. Rotational scanning was quite slow with respect to the other strategies, although it was equally accurate. Hybrid Quadrant scanning improved access time but at the cost of fewer correct selections. These results demonstrated the importance of testing and comparing alternate single-switch scanning strategies.

  15. Hepatobiliary scan in neonatal Jaundice

    International Nuclear Information System (INIS)

    Nahar, Nurun; Hasan, Mizanul; Karim, M.A.

    2002-01-01

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99m Tc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  16. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  17. Role of technetium-99m planar bone scanning in the evaluation of low back pain

    International Nuclear Information System (INIS)

    Valdez, D.C.; Johnson, R.G.

    1994-01-01

    The records of 1018 patients with low back pain in a tertiary spine referral practice were reviewed. One hundred thirty-nine out of 1018 (13.6%) underwent technetium-99m planar bone scannings as part of their investigation. Seventy-three out of 139 scans (52%) showed increased uptake in some area, but only 27 out of 139 (19.4%) showed increased uptake specifically in the low back. Scans consistently yielded no findings with reference to the back when the prescan diagnosis was spinal stenosis, lumbar pain syndrome, herniated nucleus pulposus, or postlaminectomy syndrome. Some scans gave positive findings in patients with a diagnosis of degenerative disc disease, pseudoarthrosis, spondylolisthesis, fracture, infection, metabolic disorder, or tumor. Positive scans were generally obtained early after presentation (within 3 months) and negative scans obtained later (after 6 months), suggesting that clinical suspicion is still the main indication for early scanning. Planar bone scanning was helpful in both diagnosis and therapeutic decision-making in many conditions. (orig.)

  18. Indications of {sup 99m}Tc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties; Place actuelle de la scintigraphie osseuse dans l'evaluation des protheses de hanches douloureuses

    Energy Technology Data Exchange (ETDEWEB)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M. [Centre Hospitalier Universitaire, Sce de Medecine Nucleaire et Echographie, 37 - Tours (France); Rosset, P. [Centre Hospitalier Universitaire, Sce de Chirurgie Orthopedique et Traumatologique, 37 - Tours (France)

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a {sup 99}Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  19. Indicações e achados das colonoscopias nos doentes HIV-positivo: comparação com soronegativos Indications and results of colonoscopies in HIV-positive patients: comparison with seronegative patients

    Directory of Open Access Journals (Sweden)

    Carmen Ruth Manzione

    2007-03-01

    Full Text Available Embora as indicações da colonoscopia sejam semelhantes em doentes HIV-positivo, quando comparados aos soronegativos, os achados e as suas incidências parecem diferir, sendo alguns deles mais específicos para o grupo dos imunodeprimidos. OBJETIVO: Avaliar as indicações e os achados das colonoscopias comparando os doentes soropositivos com os soronegativos para o HIV. Realizamos 1909 exames entre 1997 e 2005, sendo 1341 HIV-negativo (771 mulheres e 570 homens com média etária de 51,2 anos e 568 HIV-positivo (137 mulheres e 431 homens com 34,4 anos, em média. A análise estatística dos dados estudados revelou haver mais exames em homens no grupo HIV-positivo e em mulheres entre os soronegativos. O grupo mais jovem foi o dos soropositivos. Houve mais indicações devidas a enterorragia (22,1% e dor abdominal (12,7% nos pacientes soronegativos, e diarréia crônica (45,9% entre os soropositivos. As colites e os tumores foram os achados mais comuns em pacientes HIV-positivo e a moléstia diverticular e os pólipos, os mais freqüentes entre os soronegativos. O tumor predominante nos soronegativos foi o adenocarcinoma, enquanto que entre os soropositivos foi o sarcoma de Kaposi. CONCLUSÃO: A comparação entre os grupos demonstrou haver diferenças com relação ao sexo, idade e algumas indicações. Os achados foram semelhantes, embora com freqüências distintas.Although colonoscopy indications are similar in HIV-positive patients when compared to sero-negative persons, the findings and their incidences seem to be different, and some are more specific to immunosuppressed patients. The aim of this study is to evaluate indications and findings of colonoscopies comparing patients, sero-negatives and sero-positives to HIV. We performed 1909 colonoscopies from 1997 to 2005, 1341 in HIV-negative persons (771 females and 570 males with mean age of 51.2 years old and 568 in HIV-positive people (137 females and 431 males with mean age of 34.4 years

  20. High Ki-67 score is indicative of a greater benefit from adjuvant chemotherapy when added to endocrine therapy in luminal B HER2 negative and node-positive breast cancer.

    Science.gov (United States)

    Criscitiello, Carmen; Disalvatore, Davide; De Laurentiis, Michele; Gelao, Lucia; Fumagalli, Luca; Locatelli, Marzia; Bagnardi, Vincenzo; Rotmensz, Nicole; Esposito, Angela; Minchella, Ida; De Placido, Sabino; Santangelo, Michele; Viale, Giuseppe; Goldhirsch, Aron; Curigliano, Giuseppe

    2014-02-01

    The indication of adjuvant chemotherapy for patients with highly proliferative estrogen receptor-positive breast cancer is controversial. We analyzed the predictive value of Ki67 for the efficacy of adjuvant chemotherapy in patients with estrogen receptor-positive, node-positive breast cancer. We identified 1241 patients with Luminal B early stage breast cancer with 1-3 axillary positive nodes who underwent surgery between 1995 and 2005 at the European Institute of Oncology and received adjuvant hormonotherapy and/or chemotherapy. Differences in the distribution of characteristics according to treatment were evaluated by the Chi-square test. To evaluate the effect of adding chemotherapy to hormonotherapy, the propensity score method was used to match patients' characteristics minimizing bias related to the non-random assignment of treatment. The probability of receiving chemotherapy was significantly associated with age, tumor grade, degree of hormone responsiveness, tumor size and peripheral vascular invasion. The propensity score distribution was statistically different between the two treatment groups (p chemotherapy group (log-rank test p-value 0.663). The 5-year DFS percentages were 84.6% (95% CI, 81.0-87.6%) in the hormonotherapy group and 84.2% (95% CI, 81.3-86.7%) in the hormonotherapy/chemotherapy group (log-rank test p-value 0.388). However, when analyzing the 5-year DFS by Ki-67 distribution, Subpopulation Treatment Effect Pattern Plot (STEPP) analysis showed a beneficial effect of chemotherapy in patients with highly proliferative tumor (Ki-67 ≥ 32%). The interaction between Ki-67 and treatment was statistically significant (p = 0.027). Ki67 expression identifies a subset of patients with Luminal B and node-positive breast cancer who could benefit from addition of adjuvant chemotherapy to hormonotherapy. Dichotomy was observed for Ki67 at 32% level. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Codification of scan path parameters and development of perimeter scan strategies for 3D bowl-shaped laser forming

    Science.gov (United States)

    Tavakoli, A.; Naeini, H. Moslemi; Roohi, Amir H.; Gollo, M. Hoseinpour; Shahabad, Sh. Imani

    2018-01-01

    In the 3D laser forming process, developing an appropriate laser scan pattern for producing specimens with high quality and uniformity is critical. This study presents certain principles for developing scan paths. Seven scan path parameters are considered, including: (1) combined linear or curved path; (2) type of combined linear path; (3) order of scan sequences; (4) the position of the start point in each scan; (5) continuous or discontinuous scan path; (6) direction of scan path; and (7) angular arrangement of combined linear scan paths. Regarding these path parameters, ten combined linear scan patterns are presented. Numerical simulations show continuous hexagonal, scan pattern, scanning from outer to inner path, is the optimized. In addition, it is observed the position of the start point and the angular arrangement of scan paths is the most effective path parameters. Also, further experimentations show four sequences due to creat symmetric condition enhance the height of the bowl-shaped products and uniformity. Finally, the optimized hexagonal pattern was compared with the similar circular one. In the hexagonal scan path, distortion value and standard deviation rather to edge height of formed specimen is very low, and the edge height despite of decreasing length of scan path increases significantly compared to the circular scan path. As a result, four-sequence hexagonal scan pattern is proposed as the optimized perimeter scan path to produce bowl-shaped product.

  2. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  3. Low back pain: an assessment using positional MRI and MDT.

    Science.gov (United States)

    Hedberg, Karen; Alexander, Lyndsay A; Cooper, Kay; Hancock, Elizabeth; Ross, Jenny; Smith, Francis W

    2013-04-01

    Current guidelines advise against the use of routine imaging for low back pain. Positional MRI can provide enhanced assessment of the lumbar spine in functionally loaded positions which are often relevant to the presenting clinical symptoms. The purpose of this case report is to highlight the use of positional MRI in the assessment and classification of a subject with low back pain. A low back pain subject underwent a Mechanical Diagnosis and Therapy (MDT) assessment and positional MRI scan of the lumbar spine. The MDT assessment classified the subject as "other" since the subjective history indicated a possible posterior derangement whilst the objective assessment indicated a possible anterior derangement. Positional MRI scanning in flexed, upright and extended sitting postures confirmed the MDT assessment findings to reveal a dynamic spinal stenosis which reduced in flexion and increased in extension. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  5. Bone scanning in the evaluation of lung cancer

    International Nuclear Information System (INIS)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk

    1994-01-01

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%

  6. Bone scanning in the evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-05-15

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%.

  7. SU-G-JeP3-15: Is the Reproducibility with Respect to Bone of Tumor Position at Simulation for Breath Hold CT Scans Correlated to the Reproducibility for Multiple Breath Hold CBCTs at Treatment in SBRT Thoracic Patients?

    Energy Technology Data Exchange (ETDEWEB)

    Pollard, J; Prajapati, S; Gao, S; Nitsch, P; Sadagopan, R; Wang, X; Balter, P [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To evaluate correlation between the reproducibility of tumor position under feedback guided voluntary deep inspiration breath hold gating at simulation and at treatment. Methods: All patients treated with breath hold (BH) have 3-6 BH CTs taken at simulation (sim). In addition, if the relationship between the tumor and nearby bony anatomy on treatment BH CT(or CBCT) is found to be greater than 5 mm different at treatment than it was at sim, a repeat BH CT is taken before treatment. We retrospectively analyzed the sim CTs for 19 patients who received BH SBRT lung treatments and had repeat BH CT on treatment. We evaluated the reproducibility of the tumor position during the simulation CTs and compared this to the reproducibility of the tumor position on the repeat treatment CT with our in-house CT alignment software (CT-Assisted Targeting for Radiotherapy). Results: Comparing the tumor position for multiple simulation BH CTs, we calculated: maximum difference (max) = 0.69cm; average difference (x) = 0.28cm; standard deviation (σ) = 0.18cm. Comparing the repeat BH CBCTs on treatment days we calculated: max = 0.44cm; x = 0.16cm; σ = 0.22cm. We also found that for 95% of our BH cases, the absolute variation in tumor position within the same imaging day was within 5mm of the range at the time of simulation and treatment. We found that 75% of the BH cases had less residual tumor motion on treatment days than at simulation. Conclusion: This suggests that a GTV contour based upon the residual tumor motion in multiple BH datasets plus 2 mm margin should be sufficient to cover the full range of residual tumor motion on treatment days.

  8. Navicular bone position determined by positional MRI

    DEFF Research Database (Denmark)

    Hansen, Philip; Johannsen, Finn E; Hangaard, Stine

    2016-01-01

    -scanner). Scanning was performed in supine and standing position, respectively. Two radiologists evaluated the images in a blinded manner. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC) and 95 % limits of agreement as a percentage of the mean (LOA%). RESULTS...

  9. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  10. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ...

  12. Horizon- Scanning the Ostrich Industry with Bibliometric Indicators

    OpenAIRE

    Pittaway, Timothy; Niekerk, Pieter van

    2015-01-01

    Regional spillovers offer prospects for accelerating Africa’s agricultural productivity growth, market development and food security. West Africa has recognised and embraced the importance of regional technology transfers, agricultural commodity trade, food security monitoring and agricultural planning. In order for the Southern African region to follow suit, South Africa’s country Comprehensive Africa Agriculture Development Programme (CAADP) plan will need to recognise the country’s c...

  13. Empirical Productivity Indices and Indicators

    NARCIS (Netherlands)

    B.M. Balk (Bert)

    2016-01-01

    textabstractThe empirical measurement of productivity change (or difference) by means of indices and indicators starts with the ex post profit/loss accounts of a production unit. Key concepts are profit, leading to indicators, and profitability, leading to indices. The main task for the productivity

  14. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  15. Laser Scanning in Forests

    Directory of Open Access Journals (Sweden)

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  16. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  17. Waste indicators

    Energy Technology Data Exchange (ETDEWEB)

    Dall, O.; Lassen, C.; Hansen, E. [Cowi A/S, Lyngby (Denmark)

    2003-07-01

    The Waste Indicator Project focuses on methods to evaluate the efficiency of waste management. The project proposes the use of three indicators for resource consumption, primary energy and landfill requirements, based on the life-cycle principles applied in the EDIP Project. Trial runs are made With the indicators on paper, glass packaging and aluminium, and two models are identified for mapping the Danish waste management, of which the least extensive focuses on real and potential savings. (au)

  18. Waste indicators

    International Nuclear Information System (INIS)

    Dall, O.; Lassen, C.; Hansen, E.

    2003-01-01

    The Waste Indicator Project focuses on methods to evaluate the efficiency of waste management. The project proposes the use of three indicators for resource consumption, primary energy and landfill requirements, based on the life-cycle principles applied in the EDIP Project. Trial runs are made With the indicators on paper, glass packaging and aluminium, and two models are identified for mapping the Danish waste management, of which the least extensive focuses on real and potential savings. (au)

  19. Quality indicators

    DEFF Research Database (Denmark)

    Hjorth-Andersen, Christian

    1991-01-01

    In recent literature it has been suggested that consumers need have no knowledge of product quality as a number of quality indicators (or signals) may be used as substitutes. Very little attention has been paid to the empirical verification of these studies. The present paper is devoted...... to the issue of how well these indicators perform, using market data provided by consumer magazines from 3 countries. The results strongly indicate that price is a poor quality indicator. The paper also presents some evidence which suggests that seller reputation and easily observable characteristics are also...

  20. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans.

    Science.gov (United States)

    Chen, Xu; Guo, Tengfei; Hou, Yubin; Zhang, Jing; Meng, Wenjie; Lu, Qingyou

    2017-01-01

    A new scan-head structure for the scanning tunneling microscope (STM) is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans) coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan). They are fixed at one end (called common end). A hollow tantalum shaft is coaxially housed in the XY -scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  1. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans

    Directory of Open Access Journals (Sweden)

    Xu Chen

    2017-01-01

    Full Text Available A new scan-head structure for the scanning tunneling microscope (STM is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan. They are fixed at one end (called common end. A hollow tantalum shaft is coaxially housed in the XY-scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  2. Significance of leukocyte scanning in infected endoprostheses

    Energy Technology Data Exchange (ETDEWEB)

    Becker, W.; Pasurka, B.; Boerner, W.

    1989-03-01

    31 patients with suspected septic loosening of an endoprosthesis (hip endoprosthesis n=30; knee endoprosthesis n=1) were examined with leukocyte scans (10 MBq /sup 111/In-oxine: n=22; 300 MBq /sup 99m/Tc-HMPAO: n=9). The results were compared with results of the bacterial growth (n=22), the histology (n=12) and of the bone scans (/sup 99m/Tc-MDP: n=20) which were performed within 4 days. The sensitivity of the bone scan was 100%, the specificity 30% and the diagnostic accuracy regarding a septic loosening of the arthroplasty was 55%. For the leukocyte scans a comparable sensitivity of 100%, but a higher specificity (86%) and accuracy (91%) could be calculated. A false positive leukocyte scan could be observed in a periprosthetic granuloma, an ossifying periarthritis and in a patient with negative bacterial growth with the histological proof of an inflammation.

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine ( ... for each thyroid uptake is five minutes or less. top of page What will I experience during ...

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... evaluate changes in the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should ... such as an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the ...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... abnormal was found, and should not be a cause of concern for you. If you had an ... abnormal was found, and should not be a cause of concern for you. Actual scanning time for ...

  6. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  7. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  8. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  9. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... which are encased in metal and plastic and most often shaped like a box, attached to a ... will I experience during and after the procedure? Most thyroid scan and thyroid uptake procedures are painless. ...

  11. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... eat for several hours before your exam because eating can affect the accuracy of the uptake measurement. ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information ...

  13. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  14. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... that help physicians diagnose and evaluate medical conditions. These imaging scans use radioactive materials called radiopharmaceuticals or ... or had thyroid cancer. A physician may perform these imaging tests to: determine if the gland is ...

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Because nuclear medicine procedures are able to pinpoint molecular activity within the body, they offer the potential ... or imaging device that produces pictures and provides molecular information. The thyroid scan and thyroid uptake provide ...

  16. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Actual scanning time for each thyroid uptake is five minutes or less. top of page What will ... diagnostic procedures have been used for more than five decades, and there are no known long-term ...

  17. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Scan and Uptake Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  18. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information needed to make a diagnosis or to determine appropriate treatment, if any. Nuclear medicine is less expensive and ...

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gamma camera and single-photon emission-computed tomography (SPECT). The gamma camera, also called a scintillation ... high as with other imaging techniques, such as CT or MRI. However, nuclear medicine scans are more ...

  20. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... as an overactive thyroid gland, a condition called hyperthyroidism , cancer or other growths assess the nature of ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... painless. However, during the thyroid scan, you may feel uncomfortable when lying completely still with your head ... When the radiotracer is given intravenously, you will feel a slight pin prick when the needle is ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... energy. top of page What are some common uses of the procedure? The thyroid scan is used ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is ... computer, create pictures offering details on both the structure and function of organs and tissues in your ...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... found, and should not be a cause of concern for you. If you had an intravenous line ... found, and should not be a cause of concern for you. Actual scanning time for each thyroid ...

  6. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  7. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... You will receive specific instructions based on the type of scan you are undergoing. top of page ...

  8. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that ...

  9. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... exam of any medications you are taking, including vitamins and herbal supplements. You should also inform them ... of scan you are undergoing. top of page What does the equipment look like? The special camera ...

  11. The Scanning Optical Microscope.

    Science.gov (United States)

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  12. General indicators

    International Nuclear Information System (INIS)

    2003-01-01

    This document summarizes the main 2002 energy indicators for France. A first table lists the evolution of general indicators between 1973 and 2002: energy bill, price of imported crude oil, energy independence, primary and final energy consumption. The main 2002 results are detailed separately for natural gas, petroleum and coal (consumption, imports, exports, production, stocks, prices). (J.S.)

  13. Self-motivated visual scanning predicts flexible navigation in a virtual environment

    Directory of Open Access Journals (Sweden)

    Elisabeth Jeannette Ploran

    2014-01-01

    Full Text Available The ability to navigate flexibly (e.g., reorienting oneself based on distal landmarks to reach a learned target from a new position may rely on visual scanning during both initial experiences with the environment and subsequent test trials. Reliance on visual scanning during navigation harkens back to the concept of vicarious trial and error, a description of the side-to-side head movements made by rats as they explore previously traversed sections of a maze in an attempt to find a reward. In the current study, we examined if visual scanning predicted the extent to which participants would navigate to a learned location in a virtual environment defined by its position relative to distal landmarks. Our results demonstrated a significant positive relationship between the amount of visual scanning and participant accuracy in identifying the trained target location from a new starting position as long as the landmarks within the environment remain consistent with the period of original learning. Our findings indicate that active visual scanning of the environment is a deliberative attentional strategy that supports the formation of spatial representations for flexible navigation.

  14. Arterial scan versus radiographic angiography in detection of shallow arterial ulcers

    International Nuclear Information System (INIS)

    Pollak, E.W.; Webber, M.M.; Cragin, M.D.; Wolfman, E.F. Jr.

    1977-01-01

    A comparison of 99m-technetium albumin aggregated arterial scan and radiographic angiography for detection of shallow intimal carotid artery ulcerations was made in a series of 12 anesthetized dogs, having a total of 16 acute arterial ulcerations. Radiographic angiography showed positive findings related to presence of stenosis or mural thrombosis in 12 instances. Direct visualization of ulceration was only exceptionally encountered. Arterial scan detected 14 of 16 intimal ulcers. The radionuclide method was reliable even in absence of stenosis or when only minimal mural thrombosis was present. Moreover, autopsy scan of the isolated arterial segments detected all 16 intimal lesions. These results indicate that the arterial scan was a more reliable method for detection of shallow arterial ulcers in this experimental model than radiographic angiography, especially when arterial lumen stenosis or mural thrombosis was minimal or absent

  15. Solar Indices

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Collection includes a variety of indices related to solar activity contributed by a number of national and private solar observatories located worldwide. This...

  16. Proposal of a synchro panel meter instrument to replace the obsolete Synchro/Resolver reading device used as position indicator of safety rods assembly of the Brazilian IEA-R1 Nuclear Research Reactor

    International Nuclear Information System (INIS)

    Toledo, Fabio de; Brancaccio, Franco; Cardenas, Jose Patricio N.

    2015-01-01

    IPEN (Instituto de Pesquisas Energeticas e Nucleares) was founded in 1956 (as Atomic Energy Institute - IEA) as a facility complex, for the research, development and application, in the nuclear technology field. The institute is recognized as a national leader in nuclear research and development (R and D), including the areas of reactor operation, radiopharmaceuticals, industrial and laboratory applications, materials science and laser technologies and applications. IPEN's main facility is the IEA-R1, nuclear research reactor (NRR), today, the only one in Brazil with a power level suitable for applications in physics, chemistry, biology and engineering. Some radioisotopes are also produced in IEA-R1, for medical and other applications. A common problem faced in the IEA-R1 maintenance is instrumentation obsolescence; spare parts are no more available, because of discontinued production, and an updating program is mandatory, aiming at modernization of old-aged I and C systems. In the presented context, an electronic system is here proposed, as a replacement for the reactor safety (shim) rods assembly position indicator, based on an open-source physical computing platform called Arduino, which includes a simple microcontroller board and a software-code development environment. A mathematical algorithm for the synchro-motor signal processing was developed, and the obtained resolution was better than 1.5%. (author)

  17. Proposal of a synchro panel meter instrument to replace the obsolete Synchro/Resolver reading device used as position indicator of safety rods assembly of the Brazilian IEA-R1 Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Fabio de; Brancaccio, Franco; Cardenas, Jose Patricio N., E-mail: fatoledo@ipen.br, E-mail: fbrancac@ipen.br, E-mail: ahiru@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    IPEN (Instituto de Pesquisas Energeticas e Nucleares) was founded in 1956 (as Atomic Energy Institute - IEA) as a facility complex, for the research, development and application, in the nuclear technology field. The institute is recognized as a national leader in nuclear research and development (R and D), including the areas of reactor operation, radiopharmaceuticals, industrial and laboratory applications, materials science and laser technologies and applications. IPEN's main facility is the IEA-R1, nuclear research reactor (NRR), today, the only one in Brazil with a power level suitable for applications in physics, chemistry, biology and engineering. Some radioisotopes are also produced in IEA-R1, for medical and other applications. A common problem faced in the IEA-R1 maintenance is instrumentation obsolescence; spare parts are no more available, because of discontinued production, and an updating program is mandatory, aiming at modernization of old-aged I and C systems. In the presented context, an electronic system is here proposed, as a replacement for the reactor safety (shim) rods assembly position indicator, based on an open-source physical computing platform called Arduino, which includes a simple microcontroller board and a software-code development environment. A mathematical algorithm for the synchro-motor signal processing was developed, and the obtained resolution was better than 1.5%. (author)

  18. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  19. Frequency scanning microstrip antennas

    DEFF Research Database (Denmark)

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase......-shift. Experimental results inX-band, in good agreement with the theory, show that it is possible to scan the main lobe an angle ofpm30degby a variation of the frequencypm300MHz, and where the 3 dB beamwidth is less than10deg. The directivity was 14.7 dB, while the gain was 8.1 dB. The efficiency might be improved...

  20. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    Science.gov (United States)

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  1. Operational indicators

    International Nuclear Information System (INIS)

    2010-01-01

    The chapter presents the operational indicators related to budget, travel costs and tickets, the evolution of the annual program for regulatory inspection, the scientific production, requested patents and the numbers related to the production of the services offered by the Institution

  2. Scanning the phenomenological MSSM

    CERN Document Server

    Wuerzinger, Jonas

    2017-01-01

    A framework to perform scans in the 19-dimensional phenomenological MSSM is developed and used to re-evaluate the ATLAS experiments' sensitivity to R-parity-conserving supersymmetry with LHC Run 2 data ($\\sqrt{s}=13$ TeV), using results from 14 separate ATLAS searches. We perform a $\\tilde{t}_1$ dedicated scan, only considering models with $m_{\\tilde{t}_1}<1$ TeV, while allowing both a neutralino ($\\tilde{\\chi}_1^0$) and a sneutrino ($\\tilde{\

  3. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  4. Adaptive Optical Scanning Holography

    Science.gov (United States)

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  5. Developments in Scanning Hall Probe Microscopy

    Science.gov (United States)

    Chouinard, Taras; Chu, Ricky; David, Nigel; Broun, David

    2009-05-01

    Low temperature scanning Hall probe microscopy is a sensitive means of imaging magnetic structures with high spatial resolution and magnetic flux sensitivity approaching that of a Superconducting Quantum Interference Device. We have developed a scanning Hall probe microscope with novel features, including highly reliable coarse positioning, in situ optimization of sensor-sample alignment and capacitive transducers for linear, long range positioning measurement. This has been motivated by the need to reposition accurately above fabricated nanostructures such as small superconducting rings. Details of the design and performance will be presented as well as recent progress towards time-resolved measurements with sub nanosecond resolution.

  6. Scan path entropy and Arrow plots: Capturing scanning behavior of multiple observers

    Directory of Open Access Journals (Sweden)

    Ignace T C Hooge

    2013-12-01

    Full Text Available Designers of visual communication material want their material to attract and retain attention. In marketing research, heat maps, dwell time, and time to AOI first hit are often used as evaluation parameters. Here we present two additional measures 1 scan path entropy to quantify gaze guidance and 2 the arrow plot to visualize the average scan path. Both are based on string representations of scan paths. The latter also incorporates transition matrices and time required for 50% of the observers to first hit AOIs (T50. The new measures were tested in an eye tracking study (48 observers, 39 advertisements. Scan path entropy is a sensible measure for gaze guidance and the new visualization method reveals aspects of the average scan path and gives a better indication in what order global scanning takes place.

  7. Clinical significance of bone scintigraphy and computerized tomography (CT scan) in the evaluation of renal osteodystrophy in haemodialysed and non-haemodialysed patients

    International Nuclear Information System (INIS)

    Yatsuboshi, Motohiko

    1978-01-01

    For the evaluation of renal osteodystophy in both haemodialysed and non-haemodialysed patients, bone scintigraphy and computerized tomography (CT) scan were performed. Twenty-six patients with chronic renal failure were objectives of the study. For the control study of CT scan, patients with brain tumor without renal disease were selected. Bone scan was performed approximately 3 hours after sup(99m) Tc-EHDP (ethane-1-hydroxy-1, 1-diphosphonate) administration. The numericals which were printed out from CT scanner were analyzed in the area of frontal bone. The number of positive group was 9 and that of negative was 17. Positive group in non-haemodialysed patients showed lower serum calcium level and creatinine clearance and higher serum levels of inorganic phosphate and BUN compared with those of negative group. Positive scan group showed longer duration of dialysis and higher serum levels of parathyroid hormone and alkaline phosphatase than those of negative group. Frequency of abnormal findings detected by bone scan was higher than that elicited by roentgenographic examination. CT number of positive scan group was lower than that of negative group or control group. CT number in patients with subperiosteal resorption of phalanx and abnormal findings of calvarium was lower than that of patients without such roentgenographic abnormalities. These findings indicate that bone scan is useful in detecting bone changes of secondary hyperparathyroidism in chronic renal failure. CT scan could also help to estimate the decrease of bone density of calvarium in chronic renal failure. (author)

  8. Slope excavation quality assessment and excavated volume calculation in hydraulic projects based on laser scanning technology

    Directory of Open Access Journals (Sweden)

    Chao Hu

    2015-04-01

    Full Text Available Slope excavation is one of the most crucial steps in the construction of a hydraulic project. Excavation project quality assessment and excavated volume calculation are critical in construction management. The positioning of excavation projects using traditional instruments is inefficient and may cause error. To improve the efficiency and precision of calculation and assessment, three-dimensional laser scanning technology was used for slope excavation quality assessment. An efficient data acquisition, processing, and management workflow was presented in this study. Based on the quality control indices, including the average gradient, slope toe elevation, and overbreak and underbreak, cross-sectional quality assessment and holistic quality assessment methods were proposed to assess the slope excavation quality with laser-scanned data. An algorithm was also presented to calculate the excavated volume with laser-scanned data. A field application and a laboratory experiment were carried out to verify the feasibility of these methods for excavation quality assessment and excavated volume calculation. The results show that the quality assessment indices can be obtained rapidly and accurately with design parameters and scanned data, and the results of holistic quality assessment are consistent with those of cross-sectional quality assessment. In addition, the time consumption in excavation quality assessment with the laser scanning technology can be reduced by 70%–90%, as compared with the traditional method. The excavated volume calculated with the scanned data only slightly differs from measured data, demonstrating the applicability of the excavated volume calculation method presented in this study.

  9. Renal mobility during uncoached quiet respiration: An analysis of 4DCT scans

    International Nuclear Information System (INIS)

    Soernsen de Koste, John R. van; Senan, Suresh; Kleynen, Catharina E.; Slotman, Ben J.; Lagerwaard, Frank J.

    2006-01-01

    Purpose: Data on organ mobility is required for optimizing radiotherapy. Renal mobility was studied in four-dimensional computed tomography (4DCT) scans acquired during uncoached respiration. Methods and Materials: The 4DCT scans of 54 patients, in whom at least the upper pole of both kidneys were visualized in all 10 respiratory phases, were analyzed. Scans were performed on a 16-slice CT scanner (slice index and reconstruction, 2.5 mm) during quiet, uncoached respiration. Mobility of the renal apex was evaluated in all patients by use of the z-position on CT slices. Reproducibility of mobility was studied in 8 patients who underwent 1 or 2 repeat 4DCT scans. Results: Mobility was predominantly craniocaudal, with a mean of 9.8 mm for the left kidney and 9.0 mm for the right kidney. Large interpatient variations were observed that ranged from 2.5 to 30 mm (left) and 2.5 to 20 mm (right), and mobility of 1 kidney did not predict for mobility of the contralateral organ. Reproducibility of renal mobility and position at end-expiration was poor, with positional variations in repeat scans appearing to correlate with changes in the amplitude of respiratory waveform and total lung volume. Conclusions: Large interpatient variations in renal movement occur during uncoached respiration, which indicates that respiratory coaching is useful for 4DCT imaging and treatment delivery

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake ...

  11. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  12. Scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1970-05-15

    The JSM-11 scanning electron microscope at CRNL has been used extensively for topographical studies of oxidized metals, fracture surfaces, entomological and biological specimens. A non-dispersive X-ray attachment permits the microanalysis of the surface features. Techniques for the production of electron channeling patterns have been developed. (author)

  13. Scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Binnig, G.; Rohrer, H.

    1983-01-01

    Based on vacuum tunneling, a novel type of microscope, the scanning tunneling microscope (STM) was developed. It has an unprecedented resolution in real space on an atomic scale. The authors review the important technical features, illustrate the power of the STM for surface topographies and discuss its potential in other areas of science and technology. (Auth.)

  14. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... information. The thyroid scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates the rate at which the body ...

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  17. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  18. Scanning electron microscope

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  19. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  20. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... you: have had any tests, such as an x-ray or CT scan, surgeries or treatments using iodinated ... page How does the procedure work? With ordinary x-ray examinations, an image is made by passing x- ...

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine (I-123 or I-131) in liquid or capsule form to swallow. The thyroid uptake will begin several hours to 24 hours later. Often, two separate uptake ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two months. are taking medications or ingesting other substances that contain iodine , including kelp, seaweed, cough syrups, multivitamins or heart medications. have any ...

  3. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  4. Early Chemotherapy Intensification With Escalated BEACOPP in Patients With Advanced-Stage Hodgkin Lymphoma With a Positive Interim Positron Emission Tomography/Computed Tomography Scan After Two ABVD Cycles: Long-Term Results of the GITIL/FIL HD 0607 Trial.

    Science.gov (United States)

    Gallamini, Andrea; Tarella, Corrado; Viviani, Simonetta; Rossi, Andrea; Patti, Caterina; Mulé, Antonino; Picardi, Marco; Romano, Alessandra; Cantonetti, Maria; La Nasa, Giorgio; Trentin, Livio; Bolis, Silvia; Rapezzi, Davide; Battistini, Roberta; Gottardi, Daniela; Gavarotti, Paolo; Corradini, Paolo; Cimminiello, Michele; Schiavotto, Corrado; Parvis, Guido; Zanotti, Roberta; Gini, Guido; Ferreri, Andrés J M; Viero, Piera; Miglino, Maurizio; Billio, Atto; Avigdor, Abraham; Biggi, Alberto; Fallanca, Federico; Ficola, Umberto; Gregianin, Michele; Chiaravalloti, Agostino; Prosperini, Giuseppe; Bergesio, Fabrizio; Chauvie, Stephane; Pavoni, Chiara; Gianni, Alessandro Massimo; Rambaldi, Alessandro

    2018-02-10

    Purpose To investigate the progression-free survival (PFS) of patients with advanced Hodgkin lymphoma (HL) after a risk-adapted treatment strategy that was based on a positive positron emission tomography scan performed after two doxorubicin, vinblastine, vincristine, and dacarbazine (ABVD) cycles (PET2). Patients and Methods Patients with advanced-stage (IIB to IVB) HL were consecutively enrolled. After two ABVD cycles, PET2 was performed and centrally reviewed according to the Deauville five-point scale. Patients with a positive PET2 were randomly assigned to four cycles of escalated bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (BEACOPP) followed by four cycles of standard BEACOPP with or without rituximab. Patients with a negative PET2 continued ABVD, and those with a large nodal mass at diagnosis (≥ 5 cm) in complete remission with a negative PET at the end of chemotherapy were randomly assigned to radiotherapy or no further treatment. The primary end point was 3-year PFS. Results Of 782 enrolled patients, 150 (19%) had a positive and 630 (81%) a negative PET2. The 3-year PFS of all patients was 82%. The 3-year PFS of those with a positive and negative PET2 was 60% and 87%, respectively ( P < .001). The 3-year PFS of patients with a positive PET2 assigned to BEACOPP with or without rituximab was 63% versus 57% ( P = .53). In 296 patients with both interim and post-ABVD-negative PET who had a large nodal mass at diagnosis, radiotherapy was randomly added after chemotherapy without a significant PFS improvement (97% v 93%, respectively; P = .29). The 3-year overall survival of all 782 patients was 97% (99% and 89% for PET2 negative and positive, respectively). Conclusion The PET-driven switch from ABVD to escalated BEACOPP is feasible and effective in high-risk patients with advanced-stage HL.

  5. Laser scanning of experimental solar cells

    Science.gov (United States)

    Plunkett, B. C.; Lasswell, P. G.

    1980-01-01

    A description is presented of a laser scanning instrument which makes it possible to display and measure the spatial response of a solar cell. Examples are presented to illustrate the use of generated micrographs in the isolation of flaws and features of the cell. The laser scanner system uses a 4 mW, CW helium-neon laser, operating a wavelength of 0.633 micrometers. The beam is deflected by two mirror galvanometers arranged to scan in orthogonal directions. After being focused on the solar cell by the beam focusing lens, the moving light spot raster scans the specimen. The current output of the photovoltaic device under test, as a function of the scan dot position, can be displayed in several modes. The laser scanner has proved to be a very useful diagnostic tool in optimizing the process design of transparent metal film photovoltaic devices on Zn3P2, a relatively new photovoltaic material.

  6. Three phase bone scan , Ga-67 and Tc-99m nanocoll scan in detection of osteomyelitis caused by war injuries

    International Nuclear Information System (INIS)

    Banek, T.; Reljica-Kostic, Z.; Kurnik, G.

    1994-01-01

    Thirty three injured soldiers were surgically treated because of pierce wounds of extremities. Treatment was either osteosynthesis or external fixation. Two to four weeks post treatment clinical signs of osteomyelitis appeared. X-ray was negative in all patients. Three-phase bone scan was performed in order to establish diagnosis. Bone scan was positive in all patients. For 11 patients only bone scan was sufficient for decision of further treatment. In 22 patients Ga-67 or Tc-99m- nanocoll or both examinations were performed on surgeon's request. In 2 patients out of 5 with additional Ga-67 scan, Ga-67 scan showed more lesions than it was seen on bone scan. In 3 patients out of 5 with additional Tc-99m-nanocoll scan, Tc-99m-nanocoll scan showed more lesions than it was seen on bone scan. In 12 patients with positive bone scan and negative or unclear Ga-67, Tc-99m-nanocoll scan was performed. In 5 out of 12 patients Tc-99m- nanocoll scan established diagnosis in others confirmed finding on bone and Ga-67 scan. Our results showed that in one third of our causes bone scan was sufficient for diagnosing of osteomyelitis caused by war injuries. In selected cases where bone scan was not sufficient for diagnosis and decision for treatment Tc-99m-nanocoll was more sensitive than Ga-67. In our experience three-phase bone scan is more sensitive than Ga-67. In our opinion three-phase bone scan is the method of choice for diagnosing osteomyelitis in war situation with a lot of casualties. (author)

  7. Optical vortex scanning inside the Gaussian beam

    International Nuclear Information System (INIS)

    Masajada, J; Leniec, M; Augustyniak, I

    2011-01-01

    We discussed a new scanning method for optical vortex-based scanning microscopy. The optical vortex is introduced into the incident Gaussian beam by a vortex lens. Then the beam with the optical vortex is focused by an objective and illuminates the sample. By changing the position of the vortex lens we can shift the optical vortex position at the sample plane. By adjusting system parameters we can get 30 times smaller shift at the sample plane compared to the vortex lens shift. Moreover, if the range of vortex shifts is smaller than 3% of the beam radius in the sample plane the amplitude and phase distribution around the phase dislocation remains practically unchanged. Thus we can scan the sample topography precisely with an optical vortex

  8. Colorectal cancer detection by hyperspectral imaging using fluorescence excitation scanning

    Science.gov (United States)

    Leavesley, Silas J.; Deal, Joshua; Hill, Shante; Martin, Will A.; Lall, Malvika; Lopez, Carmen; Rider, Paul F.; Rich, Thomas C.; Boudreaux, Carole W.

    2018-02-01

    Hyperspectral imaging technologies have shown great promise for biomedical applications. These techniques have been especially useful for detection of molecular events and characterization of cell, tissue, and biomaterial composition. Unfortunately, hyperspectral imaging technologies have been slow to translate to clinical devices - likely due to increased cost and complexity of the technology as well as long acquisition times often required to sample a spectral image. We have demonstrated that hyperspectral imaging approaches which scan the fluorescence excitation spectrum can provide increased signal strength and faster imaging, compared to traditional emission-scanning approaches. We have also demonstrated that excitation-scanning approaches may be able to detect spectral differences between colonic adenomas and adenocarcinomas and normal mucosa in flash-frozen tissues. Here, we report feasibility results from using excitation-scanning hyperspectral imaging to screen pairs of fresh tumoral and nontumoral colorectal tissues. Tissues were imaged using a novel hyperspectral imaging fluorescence excitation scanning microscope, sampling a wavelength range of 360-550 nm, at 5 nm increments. Image data were corrected to achieve a NIST-traceable flat spectral response. Image data were then analyzed using a range of supervised and unsupervised classification approaches within ENVI software (Harris Geospatial Solutions). Supervised classification resulted in >99% accuracy for single-patient image data, but only 64% accuracy for multi-patient classification (n=9 to date), with the drop in accuracy due to increased false-positive detection rates. Hence, initial data indicate that this approach may be a viable detection approach, but that larger patient sample sizes need to be evaluated and the effects of inter-patient variability studied.

  9. Effective Dose of Positioning Scans for Five CBCT Devices

    Science.gov (United States)

    2016-05-25

    entire orthodontic residency. Thank you to my parents, Dan and Sue, for all of their love, babysitting, and holiday gifts over these past two years...identifying patient data and records all user actions. Log files from March 2013 to February 2015 were gathered for inclusion in the study sample

  10. Selenomethionine Se 75 thymus scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Toole, J.F.; Cowan, R.; Maynard, D.; Witcofski, R.L.; Janeway, R.

    1975-01-01

    In 1966, Toole and Witcofski introduced selenomethionine Se 75 mediastinal scanning as a diagnostic test for thymomas. Since then we have performed such scans on patients with myasthenic syndrome. Because the technique is atraumatic, safe, and accurate, it can be performed on critically ill myasthenics. Two hundred and fifty microcuries of selenomethionine Se 75 is injected intravenously. Within 1 hour the mediastinum from the suprasternal notch to the ziphoid process is scanned, using a 2 x 3 inch scanner. Delayed scans have been made in a few instances but they have not increased the number of positive cases. Selenomethionine Se 75 is incorporated into tissues undergoing rapid protein synthesis such as thyroid, pancreas, liver, and lymphomas. Of the 34 mediastinal scans performed on myasthenics between 1966 and December 31, 1974, 4 were positive for thymoma. In addition, there was a positive scan with uptake in an area of atelectasis of the lung adjacent to the mediastinum. Of interest is the fact that 1 patient with carcinoma of the lung had a positive scan over the lesion. In 13 patients with chronic lymphatic leukemia the mediastinal scans were negative. In another patient with a mediastinal mass noted on chest x-ray, a variety of differential diagnostic possibilities were considered, such as pericardial cyst, dermoid, and aneurysm. A selenomethionine scan was strongly positive, suggesting a thymoma which subsequent surgery confirmed.

  11. Scanning probe microscopy

    International Nuclear Information System (INIS)

    Mainsbridge, B.

    1994-01-01

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, 'because we are too big'. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs

  12. Scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mainsbridge, B [Murdoch Univ., WA (Australia). School of Mathematical and Physical Sciences

    1994-12-31

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, `because we are too big`. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs.

  13. Horizon Scanning for Pharmaceuticals

    DEFF Research Database (Denmark)

    Lepage-Nefkens, Isabelle; Douw, Karla; Mantjes, GertJan

    for a joint horizon scanning system (HSS).  We propose to create a central “horizon scanning unit” to perform the joint HS activities (a newly established unit, an existing HS unit, or a third party commissioned and financed by the collaborating countries). The unit will be responsible for the identification...... and filtration of new and emerging pharmaceutical products. It will maintain and update the HS database, organise company pipeline meetings, and disseminate the HSS’s outputs.  The HS unit works closely together with the designated national HS experts in each collaborating country. The national HS experts...... will collect country-specific information, liaise between the central HS unit and country-specific clinical and other experts, coordinate the national prioritization process (to select products for early assessment), and communicate the output of the HSS to national decision makers.  The outputs of the joint...

  14. Multichannel scanning spectrophotometer

    International Nuclear Information System (INIS)

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  15. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  16. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Shinde, Aniketa A.; Guevarra, Dan W.; Jones, Ryan J.; Marcin, Martin R.; Mitrovic, Slobodan

    2017-05-09

    Electrochemical or electrochemical and photochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  17. IMEF gamma scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

  18. IMEF gamma scanning system

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum.

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs

  19. Scanning reference electrode techniques in localized corrosion

    International Nuclear Information System (INIS)

    Isaacs, H.S.; Vyas, B.

    1979-04-01

    The principles, advantages, and implementations of scanning reference electrode techniques are reviewed. Data related to pitting, intergranular corrosion, welds and stress corrosion cracking are presented. The technique locates the position of localized corrosion and can be used to monitor the development of corrosion and changes in the corrosion rate under a wide range of conditions

  20. Scanning For Hotspots In Lamp Filaments

    Science.gov (United States)

    Powers, Charles E.; Van Sant, Tim; Leidecker, Henning

    1993-01-01

    Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

  1. Scanning unit for collectrons

    International Nuclear Information System (INIS)

    Plaige, Yves.

    1976-01-01

    This invention concerns a measurement scanning assembly for collectron type detectors. It is used in measuring the neutron flux in nuclear reactors. As the number of these detectors in a reactor can be very great, they are not usually all connected permanently to the measuring facility but rather in turn by means of a scanning device which carries out, as it were, multiplexing between all the collectrons and the input of a single measuring system. The object of the invention is a scanning assembly which is of relative simplicity through an original organisation. Specifically, according to this organisation, the collectrons outputs are grouped together in bunches, each of these bunches being processed by a multiplexing sub-assembly belonging to a first stage, the different outputs of these multiplexing subassemblies of this first stage being grouped together yet again in bunches processed by multiplexors forming a new stage and so forth. Further, this structure is specially adapted for use with collectrons by utilising a current amplifier at each multiplexing level so that from one end to the other of the multiplexing system, the commutations are carried out on currents and not on voltages [fr

  2. Forensic Scanning Electron Microscope

    Science.gov (United States)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  3. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates.

    Science.gov (United States)

    Zhang, Hao; Li, Xianqi; Chen, Yunmei; Park, Jewook; Li, An-Ping; Zhang, X-G

    2017-01-01

    We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a "rubber band" model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  4. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

    Directory of Open Access Journals (Sweden)

    Hao Zhang

    2017-01-01

    Full Text Available We present an image postprocessing framework for Scanning Tunneling Microscope (STM to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA. The numerical results on measurement from copper(111 surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  5. Study of 67Ga scan in sarcoidosis

    International Nuclear Information System (INIS)

    Han Lijun; Qu Wanyin; Liu Xiuqin

    1997-01-01

    Gallium scan and serum angiotensin-converting enzyme assay (SACE) were compared in patients with sarcoidosis. The examination of 67 Ga scan, SACE determination, pulmonary function test, chest CT and chest X-ray in 24 cases with sarcoidosis were studied. The results revealed that 4 of 24 cases had obviously high uptake of 67 Ga exceeding hepatic activity (3+) in clinical active stage, 3 patients had resembling the Greek letter lambda, symmetrically located in bilateral hilar lymph nodes, and among them two had an uptake of 67 Ga in the bilateral lacrimal and parotid gland simulating 'Panda Face'. 8 of 20 cases with inactive sarcoidosis had an abnormal 67 Ga scan (1+). In those patients with normal SACE level but increased uptake of 67 Ga, active stage of disease was demonstrated and steroid therapy was indicated. Gallium scan is a valuable method for the staging of its activity and evaluation of the therapeutic effect in the follow-up patients with sarcoidosis

  6. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  7. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration. [Preoperative scanning

    Energy Technology Data Exchange (ETDEWEB)

    Heslinga, J M; Pauwels, E K.J.; Zwaveling, A [Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis

    1982-06-05

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period.

  8. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  9. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  10. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  11. Scanning Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1988-01-01

    A confocal color laser microscope which utilizes a three color laser light source (Red: He-Ne, Green: Ar, Blue: Ar) has been developed and is finding useful applications in the semiconductor field. The color laser microscope, when compared to a conventional microscope, offers superior color separation, higher resolution, and sharper contrast. Recently some new functions including a Focus Scan Memory, a Surface Profile Measurement System, a Critical Dimension Measurement system (CD) and an Optical Beam Induced Current Function (OBIC) have been developed for the color laser microscope. This paper will discuss these new features.

  12. Scanning apparatus and method

    International Nuclear Information System (INIS)

    Brunnett, C.J.

    1980-01-01

    A novel method is described for processing the analogue signals from the photomultiplier tubes in a tomographic X-ray scanner. The system produces a series of pulses whose instantaneous frequency depends on the detected intensity of the X-radiation. A timer unit is used to determine the segment scan intervals and also to deduce the average radiation intensity detected during this interval. The overall system is claimed to possess the advantageous properties of low time delay, wide bandwidth and relative low cost. (U.K.)

  13. Bone scanning in Shin Splint evaluation

    International Nuclear Information System (INIS)

    Dumont, M.; Lamoureux, F.; Lamoureux, J.; Danais, S.; Lacoste, P.; Duranceau, J.

    1983-01-01

    Jogging is increasingly popular; in U.S.A., in 1979 more than 25 millions people were considered joggers. Lesions of the locomotive system of the lower limbs are very frequent in athletes and the Shin Splint syndrome, for one, is very frequent. However this precise clinical entity, usually X-Ray negative, is ill-known. A bone scan study in a series of 30 athletes suffering from Shin Splints is presented. The bone scans being positive and typical were highly useful in confirming the clinical diagnosis. Moreover, follow-up studies were done in a number of these patients and results correlated well with the clinical evolution [fr

  14. NEW SCANNING DEVICE FOR SCANNING TUNNELING MICROSCOPE APPLICATIONS

    NARCIS (Netherlands)

    SAWATZKY, GA; Koops, Karl Richard

    A small, single piezo XYZ translator has been developed. The device has been used as a scanner for a scanning tunneling microscope and has been tested successfully in air and in UHV. Its simple design results in a rigid and compact scanning unit which permits high scanning rates.

  15. Ultrafast scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Botkin, D.A. [California Univ., Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley Lab., CA (United States)

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  16. Translate rotate scanning method for X-ray imaging

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Kwog Cheong Tam.

    1990-01-01

    Rapid x-ray inspection of objects larger than an x-ray detector array is based on a translate rotate scanning motion of the object related to the fan beam source and detector. The scan for computerized tomography imaging is accomplished by rotating the object through 360 degrees at two or more positions relative to the source and detector array, in moving to another position the object is rotated and the object or source and detector are translated. A partial set of x-ray data is acquired at every position which are combined to obtain a full data set for complete image reconstruction. X-ray data for digital radiography imaging is acquired by scanning the object vertically at a first position at one view angle, rotating and translating the object relative to the source and detector to a second position, scanning vertically, and so on to cover the object field of view, and combining the partial data sets. (author)

  17. Metrological large range scanning probe microscope

    International Nuclear Information System (INIS)

    Dai Gaoliang; Pohlenz, Frank; Danzebrink, Hans-Ulrich; Xu Min; Hasche, Klaus; Wilkening, Guenter

    2004-01-01

    We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mmx25 mmx5 mm along x, y, and z axes, and a compact z-axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument

  18. Scan posture definition and hip girth measurement: the impact on clothing design and body scanning.

    Science.gov (United States)

    Gill, Simeon; Parker, Christopher J

    2017-08-01

    Ergonomic measurement is central to product design and development; especially for body worn products and clothing. However, there is a large variation in measurement definitions, complicated by new body scanning technology that captures measurements in a posture different to traditional manual methods. Investigations of hip measurement definitions in current clothing measurement practices supports analysis of the effect of scan posture and hip measurement definition on the circumferences of the hip. Here, the hip girth is a key clothing measurement that is not defined in current body scanning measurement standards. Sixty-four participants were scanned in the standard scan posture of a [TC] 2 body scanner, and also in a natural posture similar to that of traditional manual measurement collection. Results indicate that scan posture affects hip girth circumferences, and that some current clothing measurement practices may not define the largest lower body circumference. Recommendations are made concerning how the hip is defined in measurement practice and within body scanning for clothing product development. Practitioner Summary: The hip girth is an important measurement in garment design, yet its measurement protocol is not currently defined. We demonstrate that body posture during body scanning affects hip circumferences, and that current clothing measurement practices may not define the largest lower body circumference. This paper also provides future measurement practice recommendations.

  19. Plague and the gallium scan: case report

    International Nuclear Information System (INIS)

    Stahly, T.L.; Shoop, J.D.

    1975-01-01

    Inflammation in the right axillary lymph nodes and the meninges was detected by 67 Ga-citrate scans in an 11-year-old boy with Yersinia pestis infection. This case provides another example of 67 Ga localizing to areas of infection, indicating potential utility in future cases of bubonic plague

  20. Where is the place of bone scan in breast cancer?

    International Nuclear Information System (INIS)

    Nowferesti, G. H.; Ghavam Nasiri, M. R.; Anvari, K.

    2002-01-01

    Breast cancer is the most common female cancer in west and in Iran. The incidence in all over the world in year 2000 was 1050000 cases out of which 370000 were dead. General y bone is the most common site of distant. Metastases in beast cancer. Bone scan has an important place in the bone metastases and extent of bone disease and even in the staging and treatment protocol. In study done during 1 year, breast cancer patients and place of bone scan were studied. Every year more than 2000 new patients with cancer are diagnosed and treated in Khorasan state. And more than half of them are treated in Omid Hospital. In the year 2000 a study was done. 1336 new cases were admitted for treatment out of which 164 persons (13%) were breast cancer patients. 100 patients were selected randomly and different factors were studied. How many patients had bone scan and its place in breast cancer? Where is the most common metastatic place and relation with bone scan? The differential diagnosis in positive bone scans and comparing with radiography and patient's clinic were studied. Bone scan is positive in 35% of patients in stage III. Bone is the most common place for distant metastases in breast cancer in patients admitted in Omid hospital in year 2000. Clinical and para clinical study such as radiography and tumour markers were adjusted with bone scan, more in stages III and IV. 39 patients out of 100 studied patients had bone scan. 28 bone scan were adjusted radiologically. In 20 positive bone scan out of 28 patients with metastases 12 patients had bone metastases. Despite 5% positive bone scan in early stages can suggest that bone scan be taken for all patients with breast cancer as a basic step?

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... information about your thyroid’s size, shape, position and function that is often unattainable using other imaging procedures. ... thyroid uptake. It is a measurement of thyroid function, but does not involve imaging. Nuclear medicine is ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... may be allowed to wear your own clothing. Women should always inform their physician or technologist if ... discomfort from having to remain still or to stay in one particular position during imaging. Unless your ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... positioned on an examination table. If necessary, a nurse or technologist will insert an intravenous (IV) catheter ... necessary, you will be informed by a technologist, nurse or physician before you leave the nuclear medicine ...

  4. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  5. Number of evaluated lymph nodes and positive lymph nodes, lymph node ratio, and log odds evaluation in early-stage pancreatic ductal adenocarcinoma: numerology or valid indicators of patient outcome?

    Science.gov (United States)

    Lahat, G; Lubezky, N; Gerstenhaber, F; Nizri, E; Gysi, M; Rozenek, M; Goichman, Y; Nachmany, I; Nakache, R; Wolf, I; Klausner, J M

    2016-09-29

    We evaluated the prognostic significance and universal validity of the total number of evaluated lymph nodes (ELN), number of positive lymph nodes (PLN), lymph node ratio (LNR), and log odds of positive lymph nodes (LODDS) in a relatively large and homogenous cohort of surgically treated pancreatic ductal adenocarcinoma (PDAC) patients. Prospectively accrued data were retrospectively analyzed for 282 PDAC patients who had pancreaticoduodenectomy (PD) at our institution. Long-term survival was analyzed according to the ELN, PLN, LNR, and LODDS. Of these patients, 168 patients (59.5 %) had LN metastasis (N1). Mean ELN and PLN were 13.5 and 1.6, respectively. LN positivity correlated with a greater number of evaluated lymph nodes; positive lymph nodes were identified in 61.4 % of the patients with ELN ≥ 13 compared with 44.9 % of the patients with ELN < 13 (p = 0.014). Median overall survival (OS) and 5-year OS rate were higher in N0 than in N1 patients, 22.4 vs. 18.7 months and 35 vs. 11 %, respectively (p = 0.008). Mean LNR was 0.12; 91 patients (54.1 %) had LNR < 0.3. Among the N1 patients, median OS was comparable in those with LNR ≥ 0.3 vs. LNR < 0.3 (16.7 vs. 14.1 months, p = 0.950). Neither LODDS nor various ELN and PLN cutoff values provided more discriminative information within the group of N1 patients. Our data confirms that lymph node positivity strongly reflects PDAC biology and thus patient outcome. While a higher number of evaluated lymph nodes may provide a more accurate nodal staging, it does not have any prognostic value among N1 patients. Similarly, PLN, LNR, and LODDS had limited prognostic relevance.

  6. Indications for computerized tomography in the case of headache

    International Nuclear Information System (INIS)

    Huk, W.J.

    1987-01-01

    Of the large number of patients with headache only very few suffer from an intracranial tumor. On the other hand, brain tumors may grow silently for a long period of time. Clinical analysis of patients with headache has demonstrated that a CT-scan is not indicated in cases where an adequate cause can be found and when the headache disappears together with the underlaying cause in a reasonable amount of time. A CT-scan, however, should be performed when an adequate cause is missing, when the headache recurs with increasing frequency, intensity and duration, when it is accentuated in the morning and in certain positions, and when it is associated with personality chances, dizziness and blurred vision. In chronic headache a CT-scan is indicated when a change in the character of the headache and its various qualities (location, frequency and duration of attacks, temporal coincidence etc.) can be detected. A thorough history, including the family history, of the complains together with an accurate clinical examination will deliver the criteria to avoid unnecessary CT-scanning. (orig.) [de

  7. Scanning laser microscope for imaging nanostructured superconductors

    International Nuclear Information System (INIS)

    Ishida, Takekazu; Arai, Kohei; Akita, Yukio; Miyanari, Mitsunori; Minami, Yusuke; Yotsuya, Tsutomu; Kato, Masaru; Satoh, Kazuo; Uno, Mayumi; Shimakage, Hisashi; Miki, Shigehito; Wang, Zhen

    2010-01-01

    The nanofabrication of superconductors yields various interesting features in superconducting properties. A variety of different imaging techniques have been developed for probing the local superconducting profiles. A scanning pulsed laser microscope has been developed by the combination of the XYZ piezo-driven stages and an optical fiber with an aspheric focusing lens. The scanning laser microscope is used to understand the position-dependent properties of a superconducting MgB 2 stripline of length 100 μm and width of 3 μm under constant bias current. Our results show that the superconducting stripline can clearly be seen in the contour image of the scanning laser microscope on the signal voltage. It is suggested from the observed image that the inhomogeneity is relevant in specifying the operating conditions such as detection efficiency of the sensor.

  8. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  9. Scanning laser microscope for imaging nanostructured superconductors

    Science.gov (United States)

    Ishida, Takekazu; Arai, Kohei; Akita, Yukio; Miyanari, Mitsunori; Minami, Yusuke; Yotsuya, Tsutomu; Kato, Masaru; Satoh, Kazuo; Uno, Mayumi; Shimakage, Hisashi; Miki, Shigehito; Wang, Zhen

    2010-10-01

    The nanofabrication of superconductors yields various interesting features in superconducting properties. A variety of different imaging techniques have been developed for probing the local superconducting profiles. A scanning pulsed laser microscope has been developed by the combination of the XYZ piezo-driven stages and an optical fiber with an aspheric focusing lens. The scanning laser microscope is used to understand the position-dependent properties of a superconducting MgB 2 stripline of length 100 μm and width of 3 μm under constant bias current. Our results show that the superconducting stripline can clearly be seen in the contour image of the scanning laser microscope on the signal voltage. It is suggested from the observed image that the inhomogeneity is relevant in specifying the operating conditions such as detection efficiency of the sensor.

  10. Factors influencing bone scan quality

    International Nuclear Information System (INIS)

    Adams, F.G.; Shirley, A.W.

    1983-01-01

    A reliable subjective method of assessing bone scan quality is described. A large number of variables which theoretically could influence scan quality were submitted to regression and factor analysis. Obesity, age, sex and abnormality of scan were found to be significant but weak variables. (orig.)

  11. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  12. Scanning the periphery.

    Science.gov (United States)

    Day, George S; Schoemaker, Paul J H

    2005-11-01

    Companies often face new rivals, technologies, regulations, and other environmental changes that seem to come out of left field. How can they see these changes sooner and capitalize on them? Such changes often begin as weak signals on what the authors call the periphery, or the blurry zone at the edge of an organization's vision. As with human peripheral vision, these signals are difficult to see and interpret but can be vital to success or survival. Unfortunately, most companies lack a systematic method for determining where on the periphery they should be looking, how to interpret the weak signals they see, and how to allocate limited scanning resources. This article provides such a method-a question-based framework for helping companies scan the periphery more efficiently and effectively. The framework divides questions into three categories: learning from the past (What have been our past blind spots? What instructive analogies do other industries offer? Who in the industry is skilled at picking up weak signals and acting on them?); evaluating the present (What important signals are we rationalizing away? What are our mavericks, outliers, complainers, and defectors telling us? What are our peripheral customers and competitors really thinking?); and envisioning the future (What future surprises could really hurt or help us? What emerging technologies could change the game? Is there an unthinkable scenario that might disrupt our business?). Answering these questions is a good first step toward anticipating problems or opportunities that may appear on the business horizon. The article concludes with a self-test that companies can use to assess their need and capability for peripheral vision.

  13. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  14. Small-size low-temperature scanning tunnel microscope

    International Nuclear Information System (INIS)

    Al'tfeder, I.B.; Khajkin, M.S.

    1989-01-01

    A small-size scanning tunnel microscope, designed for operation in transport helium-filled Dewar flasks is described. The microscope design contains a device moving the pin to the tested sample surface and a piezoelectric fine positioning device. High vibration protection of the microscope is provided by its suspension using silk threads. The small-size scanning tunnel microscope provides for atomic resolution

  15. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  16. A t (11; 22 (p13; q12 EWS-WT 1 positive desmoplastic small round cell tumor of the maxilla: An unusual case indicating the role of molecular diagnosis in round cell sarcomas

    Directory of Open Access Journals (Sweden)

    Rekhi B

    2010-01-01

    Full Text Available A desmoplastic small round cell tumor (DSRCT is an uncommon tumor characterized by polyphenotypic expression and a specific reciprocal translocation t (11; 22 (p13; q12. It has been rarely identified in the head and neck region. Herein, we describe a DSRCT in the maxilla of a young man, who was initially diagnosed with a primitive neuroectodermal tumor (PNET, based on histopathological appearance of a round cell tumor, with MIC2 and -FLI-1 positivity, on immunohistochemistry (IHC. Diagnosis of a DSRCT was confirmed on molecular analysis with positive -RT-PCR and sequencing results for EWS-WT1 transcript and negativity for EWS-FL1. The case is presented to highlight the value of molecular diagnosis in round cell sarcomas at uncommon sites, especially when similar IHC markers can be expressed in a PNET and a DSRCT. An exact diagnosis of a round cell sarcoma has a therapeutic relevance.

  17. Detection of Arthritis by Joint Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, W. S. [Dept, of Radiology, Louisiana State University School of Medicine, New Orleans, LA (United States); Weiss, T. E.; Tutton, R. H.; Hidalgo, J. U. [Ochsner Clinic and Ochsner Foundation Hospital, New Orleans, LA (United States)

    1969-05-15

    Detection and identification of early arthritis is frequently difficult with routine methods. Several tracers, {sup 131}I human serum albumin (25 {mu}Ci/10 lb), {sup 99m}Tc human serum albumin (1-3 mCi), {sup 131}I iodipamide (40 {mu}Ci/10 lb), and {sup 99m}Tc pertechnetate (10 mCi), have been employed for joint scanning to detect synovitis produced by arthritis in joints of the extremities. When administered intravenously, the 25% increase in localization of these tracers in the synovial membrane, if there is active synovitis, can be demonstrated by scintillation scanning. This ability to detect synovitis at an early stage enables the joint scan to show areas of active synovitis not demonstrated on roentgenograms. The scan may objectively confirm or disprove questionable physical findings. From this standpoint the technique has been useful in determining whether joint pain is functional or due to arthritis as a negative localization tends to rule out active synovitis as the cause of the pain. The scan demonstration of a positive localization of the tracer in several joints when only one area is symptomatic is evidence that joint pain is due to systemic disease. The short half-life tracera permit serial studies to follow the course of an arthritis process. Use of {sup 99m}Tc pertechnetate and an Anger camera have made joint scanning a practical technique for clinical use. A review of the accuracy of joint scanning in 130 cases as compared to roentgenograms is presented. (author)

  18. What expects orthopedic surgeon from bone scan?

    International Nuclear Information System (INIS)

    Sutter, B.; Cazenave, A.

    2003-01-01

    The isotope bone scan continues to be one of the 'lost widely performed nuclear medicine investigations. Beyond the common clinical indication like detection of skeletal metastases, bone scan use is increasing in benign orthopedic conditions, and after orthopedic surgery, despite development of new investigations modalities (US, MRI). Three (or two) phase bone scintigraphy, Single Photon Emission Computer Tomography have increased its value and provided new clinical roles. This review emphasizes through some practical clinical examples how to increase diagnostic value of the method and to offer an adapted response to the orthopedic surgeon's attempts. (author)

  19. Position Information

    Data.gov (United States)

    Social Security Administration — The Position Information Data Asset provides the ability to search for active SSA position descriptions using various search criteria. An individual may search by PD...

  20. Positive Psychology

    Science.gov (United States)

    Peterson, Christopher

    2009-01-01

    Positive psychology is a deliberate correction to the focus of psychology on problems. Positive psychology does not deny the difficulties that people may experience but does suggest that sole attention to disorder leads to an incomplete view of the human condition. Positive psychologists concern themselves with four major topics: (1) positive…

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... and determine the severity of or treat a variety of diseases, including many types of cancers, heart ... are more sensitive than other techniques for a variety of indications, and the functional information gained from ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... your arm, but there are generally no other side effects. When swallowed, the radiotracer has little or no ... techniques for a variety of indications, and the functional information gained from nuclear medicine exams is often ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... techniques for a variety of indications, and the functional information gained from nuclear medicine exams is often ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  4. Commissioning of output factors for uniform scanning proton beams

    International Nuclear Information System (INIS)

    Zheng Yuanshui; Ramirez, Eric; Mascia, Anthony; Ding Xiaoning; Okoth, Benny; Zeidan, Omar; Hsi Wen; Harris, Ben; Schreuder, Andries N.; Keole, Sameer

    2011-01-01

    Purpose: Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. Methods: Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. Results: The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. Conclusions: Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output

  5. Ubiquitous positioning

    CERN Document Server

    Mannings, Robin

    2008-01-01

    This groundbreaking resource offers a practical, in-depth understanding of Ubiquitous Positioning - positioning systems that identify the location and position of people, vehicles and objects in time and space in the digitized networked economy. The future and growth of ubiquitous positioning will be fueled by the convergence of many other areas of technology, from mobile telematics, Internet technology, and location systems, to sensing systems, geographic information systems, and the semantic web. This first-of-its-kind volume explores ubiquitous positioning from a convergence perspective, of

  6. Liver scanning in short interval autopsy material of cancer patients

    International Nuclear Information System (INIS)

    Appelqvist, P.; Salmo, M.; Kostiainen, S.

    1980-01-01

    The accuracy of liverscanning alkaline phosphatase and 5'-nucleotidase in the detection of the hepatic metastases was studied in short interval autopsy material of 243 cancer patients. The highest percentage of correct diagnosis was by 5'-nucleotidase, alkaline phosphatase was the second, and scanning third. The overall accuracy of liver scan was 68 per cent. It was the better the shorter the time interval between scanning and autopsy. The higher percentage of incorrect diagnoses of the scan was related to a larger number of false positives, the causes of which were to be verified only in half of the cases. (orig.) [de

  7. Nuclear scanning in necrotizing progressive ''malignant'' external otitis

    International Nuclear Information System (INIS)

    Parisier, S.C.; Lucente, F.E.; Som, P.M.; Hirschman, S.Z.; Arnold, L.M.; Roffman, J.D.

    1982-01-01

    The usefulness of radionuclear scanning in the treatment of 18 patients with necrotizing progressive ''malignant'' external otitis is discussed. A Tc 99-m bone scan, a valuable test since results are positive in early cases of osteomyelitis of the temporal bone and base of skull, showed increased uptake in all 18 patients. In 6 patients, Ga-67 citrate scans were obtained at the start of therapy and at 5-6 week intervals thereafter. The serial gallium scans were useful in evaluating the effectiveness of therapy since the uptake decrease with control of infection

  8. Positioning consumption

    DEFF Research Database (Denmark)

    Halkier, Bente; Keller, Margit

    2014-01-01

    positionings emerges based on empirical examples of research in parent–children consumption. Positionings are flexible discursive fixations of the relationship between the performances of the practitioner, other practitioners, media discourse and consumption activities. The basic positioning types...... are the practice maintenance and the practice change position, with different sorts of adapting in between. Media discourse can become a resource for a resistant position against social control or for an appropriating position in favour of space for action. Regardless of the current relation to a particular media......This article analyses the ways in which media discourses become a part of contested consumption activities. We apply a positioning perspective with practice theory to focus on how practitioners relate to media discourse as a symbolic resource in their everyday practices. A typology of performance...

  9. Identification of tetrapeptides from a mixture based positional scanning library that can restore nM full agonist function of the L106P, I69T, I102S, A219V, C271Y, and C271R human melanocortin-4 polymorphic receptors (hMC4Rs).

    Science.gov (United States)

    Haslach, Erica M; Huang, Huisuo; Dirain, Marvin; Debevec, Ginamarie; Geer, Phaedra; Santos, Radleigh G; Giulianotti, Marc A; Pinilla, Clemencia; Appel, Jon R; Doering, Skye R; Walters, Michael A; Houghten, Richard A; Haskell-Luevano, Carrie

    2014-06-12

    Human obesity has been linked to genetic factors and single nucleotide polymorphisms (SNPs). Melanocortin-4 receptor (MC4R) SNPs have been associated with up to 6% frequency in morbidly obese children and adults. A potential therapy for individuals possessing such genetic modifications is the identification of molecules that can restore proper receptor signaling and function. These compounds could serve as personalized medications improving quality of life issues as well as alleviating diseases symptoms associated with obesity including type 2 diabetes. Several hMC4 SNP receptors have been pharmacologically characterized in vitro to have a decreased, or a lack of response, to endogenous agonists such as α-, β-, and γ2-melanocyte stimulating hormones (MSH) and adrenocorticotropin hormone (ACTH). Herein we report the use of a mixture based positional scanning combinatorial tetrapeptide library to discover molecules with nM full agonist potency and efficacy to the L106P, I69T, I102S, A219V, C271Y, and C271R hMC4Rs. The most potent compounds at all these hMC4R SNPs include Ac-His-(pI)DPhe-Tic-(pNO2)DPhe-NH2, Ac-His-(pCl)DPhe-Tic-(pNO2)DPhe-NH2, Ac-His-(pCl)DPhe-Arg-(pI)Phe-NH2, and Ac-Arg-(pCl)DPhe-Tic-(pNO2)DPhe-NH2, revealing new ligand pharmacophore models for melanocortin receptor drug design strategies.

  10. GPR scan assessment

    Directory of Open Access Journals (Sweden)

    Abbas M. Abbas

    2015-06-01

    Full Text Available Mekaad Radwan monument is situated in the neighborhood of Bab Zuweila in the historical Cairo, Egypt. It was constructed at the middle XVII century (1635 AD. The building has a rectangle shape plan (13 × 6 m with the longitudinal sides approximately WNW-ESE. It comprises three storages namely; the ground floor; the opened floor (RADWAN Bench and the living floor with a total elevation of 15 m above the street level. The building suffers from severe deterioration phenomena with patterns of damage which have occurred over time. These deterioration and damages could be attributed to foundation problems, subsoil water and also to the earthquake that affected the entire Greater Cairo area in October 1992. Ground Penetrating Radar (GPR scan was accomplished against the walls of the opened floor (RADWAN Bench to evaluate the hazard impact on the walls textures and integrity. The results showed an anomalous feature through the southern wall of RADWAN Bench. A mathematical model has been simulated to confirm the obtained anomaly and the model response exhibited a good matching with the outlined anomaly.

  11. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  12. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  13. Gastrointestinal scanning agent

    International Nuclear Information System (INIS)

    Francis, M.D.

    1980-01-01

    An easily prepared radiolabeled gastrointestinal scanning agent is described. Technetium-99m has ideal characteristics for imaging the upper and lower GI tract and determining stomach emptying and intestinal transit time when used with an insoluble particulate material. For example, crystalline and amorphous calcium phosphate particles can be effectively labeled in a one-step process using sup(99m)TcO 4 and SnCl 2 . These labeled particles have insignificant mass and when administered orally pass through the GI tract unchanged, without affecting the handling and density of the intestinal contents. Visualization of the esophageal entry into the stomach, the greater and lesser curvatures of the stomach, ejection into the duodenum, and rates of passage through the upper and lower GI tract are obtained. The slurry of sup(99m)TC particulate can be given rectally by enema. Good images of the cecum and the ascending, transverse, and descending colon are obtained. Mucosal folds and the splenic and hepatic flexures are visualized. The resilience of the large intestine is also readily visualized by pneumocolonographic techniques. (author)

  14. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  15. Construction of a four tip scanning tunneling microscope/scanning electron microscope combination and conductivity measurements of silicide nanowires

    International Nuclear Information System (INIS)

    Zubkov, Evgeniy

    2013-01-01

    In this work the combination of a four-tip scanning tunneling microscope with a scanning electron microscope is presented. By means of this apparatus it is possible to perform the conductivity measurements on the in-situ prepared nanostructures in ultra-high vacuum. With the aid of a scanning electron microscope (SEM), it becomes possible to position the tunneling tips of the four-tip scanning tunneling microscope (STM), so that an arrangement for a four-point probe measurement on nanostructures can be obtained. The STM head was built according to the novel coaxial Beetle concept. This concept allows on the one hand, a very compact arrangement of the components of the STM and on the other hand, the new-built STM head has a good mechanical stability, in order to achieve atomic resolution with all four STM units. The atomic resolution of the STM units was confirmed by scanning a Si(111)-7 x 7 surface. The thermal drift during the STM operation, as well as the resonant frequencies of the mechanical structure of the STM head, were determined. The scanning electron microscope allows the precise and safe navigation of the tunneling tips on the sample surface. Multi tip spectroscopy with up to four STM units can be performed synchronously. To demonstrate the capabilities of the new-built apparatus the conductivity measurements were carried out on metallic yttrium silicide nanowires. The nanowires were prepared by the in-situ deposition of yttrium on a heated Si(110) sample surface. Current-voltage curves were recorded on the nanowires and on the wetting layer in-between. The curves indicate an existence of the Schottky barrier between the yttrium silicide nanowires and the silicon bulk. By means of the two-tip measurements with a gate, the insulating property of the Schottky barrier has been confirmed. Using this Schottky barrier, it is possible to limit the current to the nanowire and to prevent it from flowing through the silicon bulk. A four-tip resistance measurement

  16. Hyperchromatic laser scanning cytometry

    Science.gov (United States)

    Tárnok, Attila; Mittag, Anja

    2007-02-01

    In the emerging fields of high-content and high-throughput single cell analysis for Systems Biology and Cytomics multi- and polychromatic analysis of biological specimens has become increasingly important. Combining different technologies and staining methods polychromatic analysis (i.e. using 8 or more fluorescent colors at a time) can be pushed forward to measure anything stainable in a cell, an approach termed hyperchromatic cytometry. For cytometric cell analysis microscope based Slide Based Cytometry (SBC) technologies are ideal as, unlike flow cytometry, they are non-consumptive, i.e. the analyzed sample is fixed on the slide. Based on the feature of relocation identical cells can be subsequently reanalyzed. In this manner data on the single cell level after manipulation steps can be collected. In this overview various components for hyperchromatic cytometry are demonstrated for a SBC instrument, the Laser Scanning Cytometer (Compucyte Corp., Cambridge, MA): 1) polychromatic cytometry, 2) iterative restaining (using the same fluorochrome for restaining and subsequent reanalysis), 3) differential photobleaching (differentiating fluorochromes by their different photostability), 4) photoactivation (activating fluorescent nanoparticles or photocaged dyes), and 5) photodestruction (destruction of FRET dyes). With the intelligent combination of several of these techniques hyperchromatic cytometry allows to quantify and analyze virtually all components of relevance on the identical cell. The combination of high-throughput and high-content SBC analysis with high-resolution confocal imaging allows clear verification of phenotypically distinct subpopulations of cells with structural information. The information gained per specimen is only limited by the number of available antibodies and by sterical hindrance.

  17. Vacuum scanning capillary photoemission microscopy.

    Science.gov (United States)

    Aseyev, S A; Cherkun, A P; Mironov, B N; Petrunin, V V; Chekalin, S V

    2017-08-01

    We demonstrate the use of a conical capillary in a scanning probe microscopy for surface analysis. The probe can measure photoemission from a substrate by transmitting photoelectrons along the capillary as a function of probe position. The technique is demonstrated on a model substrate consisting of a gold reflecting layer on a compact disc which has been illuminated by an unfocused laser beam with a wavelength 400nm, from a femtosecond laser with a beam size of 4mm. A quartz capillary with a 2-µm aperture has been used in the experiments. The period of gold microstructure, shown to be 1.6µ, was measured by the conical probe operating in shear force mode. In shear force regime, the dielectric capillary has been used as a "classical" SPM tip, which provided images reflecting the surface topology. In a photoelectron regime photoelectrons passed through hollow tip and entered a detector. The spatial distribution of the recorded photoelectrons consisted of periodic mountain-valley strips, resembling the surface profile of the sample. Submicron spatial resolution has been achieved. This approach paves the way to study pulsed photodesorption of large organic molecular ions with high spatial and element resolution using the combination of a hollow-tip scanner with time-of-flight technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Tumor scanning with /sup 57/Co-bleomycin

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S; Hasegawa, Y; Matsuda, Minoru; Ho, T; Doi, O [Osaka Prefectural Center for Adult Diseases (Japan)

    1975-06-01

    The clinical application of /sup 57/Co-bleomycin as a tumor scanning radiopharmaceutical was firstly reported by Nouel and Maeda respectively. The authors conducted studies on the diagnostic significance of this tumor scanning agent and presented the results obtained in 40 patients with malignant and non malignant lesions. Six hours and 24 hours after the injection of 500 ..mu..Ci of /sup 57/Co-bleomycin, scintigrams were taken with a 3-inch scintiscanner. Positive scans were found in 20 out of 36 patients with various malignant tumors. Of 20 patients with lung cancer, positive scans were obtained in 17 cases (85%) and of 6 with breast cancer, 3 cases showed positive scans. False negative scans were obtained in another 10 cases of malignant tumors (3 cases of thyroid carcinoma, 4 cases of hepatoma, and 1 case each of gastric carcinoma, peritoneal carcinomatosis, and reticulum cell sarcoma). Of 4 patients with non malignant disease, one case of pulmonary tuberculosis showed a positive scan. In 8 cases of lung cancer and 6 of breast cancer, the relationship between the size of the excised tumor and the scintigram findings was studied. The smallest tumors detected by scintigram were 2 cm in lung cancer and 3.2 cm in breast cancer.

  19. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    International Nuclear Information System (INIS)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-01-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results

  20. Evaluation of muscular lesions in connective tissue diseases: thallium 201 muscular scans

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, G.; Guillet, J.; Sanciaume, C.; Maleville, J.; Geniaux, M.; Morin, P.

    1988-04-01

    We performed thallium 201 muscle scans to assess muscular involvement in 40 patients with different connective tissue diseases (7 with dermatomyositis, 7 with systemic lupus erythematosus, 12 with progressive systemic scleroderma, 2 with calcinosis, Raynaud's phenomenon, esophageal involvement, sclerodactyly, and telangiectasia (CREST) syndrome, 3 with monomelic scleroderma, 6 with morphea, and 3 with Raynaud's disease). Only 12 of these patients complained of fatigability and/or myalgia. Electromyography was performed and serum levels of muscle enzymes were measured in all patients. Comparison of thallium 201 exercise recording with the other tests revealed that scan sensitivity is greater than electromyographic and serum muscle enzymes levels. Thallium 201 scans showed abnormal findings in 32 patients and revealed subclinical lesions in 18 patients, while electromyography findings were abnormal in 25 of these 32 patients. Serum enzyme levels were raised in only 8 patients. Thallium 201 scanning proved to be a useful guide for modifying therapy when laboratory data were conflicting. It was useful to evaluate treatment efficacy. Because our data indicate a 100% positive predictive value, we believe that thallium 201 scanning should be advised for severe systemic connective tissue diseases with discordant test results.

  1. Is scanning in probed order recall articulatory?

    Science.gov (United States)

    Farrell, Simon; Lelièvre, Anna

    2009-09-01

    We consider how theories of serial recall might apply to other short-term memory tasks involving recall of order. In particular, we consider the possibility that when participants are cued to recall an item at an arbitrary position in a sequence, they covertly serially recall the list up to the cued position. One question is whether such "scanning" is articulatory in nature. Two experiments are presented in which the syllabic length of words preceding and following target positions were manipulated, to test the prediction of an articulatory-based mechanism that time to recall an item at a particular position will depend on the number of preceding long words. Although latency was dependent on target position, no word length effects on latency were observed. Additionally, the effects of word length on accuracy replicate recent demonstrations in serial recall that recall accuracy is dependent on the word length of all list items, not just that of target items, in line with distinctiveness assumptions. It is concluded that if scanning does occur, it is not carried out by covert or overt articulation.

  2. Magnetically scanned proton therapy beams: rationales and techniques

    International Nuclear Information System (INIS)

    Jones, D.T.L.; Schreuder, A.N.

    2000-01-01

    Perhaps the most important advantages of beam scanning systems for proton therapy in comparison with conventional passive beam spreading systems are: (1) Intensity modulation and inverse planning are possible. (2) There is negligible reduction in the range of the beam. (3) Integral dose is reduced as dose conformation to the proximal edge of the lesion is possible. (4) In principle no field-specific modifying devices are required. (5) There is less activation of the surroundings. (6) Scanning systems axe almost infinitely flexible. The main disadvantages include: (1) Scanning systems are more complicated and therefore potentially less reliable and more dangerous. (2) The development of such systems is more demanding in terms of cost, time and manpower. (3) More stable beams are required. (4) Dose and beam position monitoring are more difficult. (5) The problems associated with patient and organ movement axe more severe. There are several techniques which can be used for scanning. For lateral beam spreading, circular scanning (wobbling) or linear scanning can be done. In the latter case the beam can be scanned continuously or in a discrete fashion (spot scanning). Another possibility is to undertake the fastest scan in one dimension (strip scanning) and translate the patient or the scanning magnet in the other dimension. Depth variation is achieved by interposing degraders in the beam (cyclotrons) or by changing the beam energy (synchrotrons). The aim of beam scanning is to deliver a predetermined dose at any point in the body. Special safety precautions must be taken because of the high instantaneous dose rates. The beam position and the dose delivered at each point must be accurately and redundantly determined. (author)

  3. Large Scale Scanning Probe Microscope "Making Shear Force Scanning visible."

    NARCIS (Netherlands)

    Bosma, E.; Offerhaus, Herman L.; van der Veen, Jan T.; van der Veen, J.T.; Segerink, Franciscus B.; Wessel, I.M.

    2010-01-01

    We describe a demonstration of a scanning probe microscope with shear-force tuning fork feedback. The tuning fork is several centimeters long, and the rigid fiber is replaced by a toothpick. By scaling this demonstration to visible dimensions the accessibility of shear-force scanning and tuning fork

  4. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  5. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  6. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  7. Three phase bone scan in sports injuries

    International Nuclear Information System (INIS)

    Chauhan, M.S.; Chowhan, M.

    2007-01-01

    Full text: Sports injuries are common in individual who participate in sports and exercise related activities. In majority of sports related injuries such as stress fracture, periosteitits, acute stress reaction of bone, the radiological investigations are usually normal in early stages. These injuries can lead to serious complications if not detected early and managed properly. This study was jointly carried out in premier medical institutes. All patients were referred from premier sports institute of the country and also by orthopedic surgeons. All patients were subjected for relevant radiological investigations and 3 phase bone scan. Total number of cases included in this study was 70 (N=70) among which bone scan was positive for stress fracture in 45 patients and shin splint was detected in 15 patients and avulsion injury seen in 3 patients. However, only one patient showed features of avulsion injury in X ray and in 1 patient X-ray was inconclusive. Conclusion:-The study shows that 3 phase bone scan is the most sensitive and relatively an inexpensive study. Bone scan has the ability for early detection of sports injuries and provide physiological information and evaluate multiple sites in single examination.SPECT study will help in the diagnostic specificity. (author)

  8. Clinical role of skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J

    1975-12-01

    Malignant disease very often spreads to the skeleton. This is particularly true for carcinomas of the breast, the lungs, the prostate, and the thyroid. Knowledge of the state of the skeleton in these disorders is therefore desirable since patient management will largely depend on the early detection of bony deposits. Primary bone disease often spreads to soft tissue (lungs), and the early detection of this may alter significantly the therapeutic approach to the primary lesion. Traditionally, x-ray skeletal surveys and serum enzyme measurements provide indices which can be used in the staging of these disorders. Complementary techniques such as mammography, xeroradiography, thermography, and radionuclide imaging have been used to provide further relevant information. A number of benign bone diseases need early assessment in order to institute the best form of treatment. It is of importance to assess the circulation in localized areas of bone and to predict the appearance of avascular necrosis, to understand the healing mechanisms involved in fractures, and to predict the outcome of bone grafting. In this paper the clinical role of bone scanning is reviewed, particular attention being given to the recent advances brought about by the introduction of the /sup 99m/Tc compounds. It is important that the non-specialist should be aware of the great improvement in the results obtained and in the help they can give him in deciding on the best management of each patient as an individual.

  9. Researcher positioning

    DEFF Research Database (Denmark)

    Mørck, Line Lerche; Khawaja, Iram

    2009-01-01

    abstract  This article focuses on the complex and multi-layered process of researcher positioning, specifically in relation to the politically sensitive study of marginalised and ‘othered' groups such as Muslims living in Denmark. We discuss the impact of different ethnic, religious and racial...... political and personal involvement by the researcher, which challenges traditional perspectives on research and researcher positioning. A key point in this regard is the importance of constant awareness of and reflection on the multiple ways in which one's positioning as a researcher influences the research...

  10. Safe Active Scanning for Energy Delivery Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Helms, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Salazar, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Scheibel, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Engels, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reiger, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-30

    The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

  11. Over-all accuracy of sup(99m)Tc-pertechnetate brain scanning for brain tumours

    International Nuclear Information System (INIS)

    Bjoernsson, O.G.; Petursson, E.; Sigurbjoernsson, B.; Davidsson, D.

    1978-01-01

    A 3-year follow-up and re-evaluation of all scans on all patients referred for brain scanning in Iceland during 1 year was performed in order to assess the diagnostic reliability of radioisotope scanning for brain tumours. The study included 471 patients. Of these 25 had primary brain tumours and 7 brain metastases. Scans were positive and correctly interpreted in 68% of the patients with primary brain tumours and in 3 of the 7 patients with metastases. The over-all accuracy of brain scanning for brain tumours defined as the total number of correct positive scans and correct negative scans versus total number of scans examined was 96%, this figure being mainly influenced by the high number of true negative scans. (orig.) [de

  12. Differentiation of osteomyelitis and infarction in sickle-cell hemoglobinopathies using combined bone-marrow and gallium scanning

    International Nuclear Information System (INIS)

    Hatfield, M.K.; Kahn, C.E.; Ryan, J.W.; Martin, W.B.

    1986-01-01

    The clinical records and scintigrams of patients with sickle cell hemoglobinopathies in whom acute symptoms developed suggestive of possible osteomyelitis and who had undergone sequential Tc-99m bone marrow scans and gallium scintigraphy of the affected sites were reviewed. Osteomyelitis was correctly diagnosed in six of 18 cases when gallium was focally increased relative to a site of decreased or absent bone marrow activity. Of 12 episodes of infarction, both studies showed focally decreased activity in a concordant manner in 11. The remaining, false-positive study indicated slightly increased gallium in 11. The remaining, false-positive indicated slightly increased gallium concentration at a site of decreased bone marrow activity. Overall, a protocol of sequential Tc-99m bone marrow scans and gallium scintigraphy is an effective means of distinguishing osteomyelitis from infarction in patients with sickle cell hemoglobinopathies

  13. Rapid-scan EPR imaging.

    Science.gov (United States)

    Eaton, Sandra S; Shi, Yilin; Woodcock, Lukas; Buchanan, Laura A; McPeak, Joseph; Quine, Richard W; Rinard, George A; Epel, Boris; Halpern, Howard J; Eaton, Gareth R

    2017-07-01

    In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be oscillations on the trailing edge of the spectrum. These oscillations can be removed by mathematical deconvolution to recover the slow-scan absorption spectrum. In cases of inhomogeneous broadening, the oscillations may interfere destructively to the extent that they are not visible. The deconvolution can be used even when it is not required, so spectra can be obtained in which some portions of the spectrum are in the rapid-scan regime and some are not. The technology developed for rapid-scan EPR can be applied generally so long as spectra are obtained in the linear response region. The detection of the full spectrum in each scan, the ability to use higher microwave power without saturation, and the noise filtering inherent in coherent averaging results in substantial improvement in signal-to-noise relative to conventional continuous wave spectroscopy, which is particularly advantageous for low-frequency EPR imaging. This overview describes the principles of rapid-scan EPR and the hardware used to generate the spectra. Examples are provided of its application to imaging of nitroxide radicals, diradicals, and spin-trapped radicals at a Larmor frequency of ca. 250MHz. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  15. Position encoder

    International Nuclear Information System (INIS)

    Goursky, Vsevolod

    1975-01-01

    A circuitry for deriving the quotient of signal delivered by position-sensitive detectors is described. Digital output is obtained in the form of 10- to 12-bit words. Impact position may be determined with 0.25% accuracy when the dynamic range of the energy signal is less 1:10, and 0.5% accuracy when the dynamic range is 1:20. The division requires an average time of 5μs for 10-bit words

  16. Position encoder

    International Nuclear Information System (INIS)

    Goursky, V.

    1975-05-01

    This paper describes circuitry for deriving the quotient of signals delivered by position-sensitive detectors. Digital output is obtained in the form of 10 to 12 bit words. Impact position may be determined with 0.25% accuracy when the dynamic range of the energy signal is less than 1:10, and 0.5% accuracy when the dynamic range is 1:20. The division requires an average time of 5μs for 10-bit words [fr

  17. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  18. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  19. Radioisotope spleen scan in patients with splenic injury

    International Nuclear Information System (INIS)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-01-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established

  20. Radioisotope spleen scan in patients with splenic injury

    Energy Technology Data Exchange (ETDEWEB)

    Mishalany, H.G.; Miller, J.H.; Woolley, M.M.

    1982-09-01

    The technetium /sup 99m/Tc sulfur colloid liver-spleen scan is a valuable aid in diagnosis and treatment of patients with splenic injury. After reviewing the charts of 47 patients who were ill as a result of splenic trauma, we came to the following conclusions: (1) the scan identified the injury, accurately mapped its extent, and indicated the presence or absence of associated liver injuries; (2) the scans were useful in following the extent and rate of healing of the splenic injury; (3) the scan is an indirect measurement of of return of splenic fuction; (4) the procedure can be performed in a reasonable time frame with no serious morbidity; and (5) the indications, contraindications, and timing of scans are now reasonably well established.

  1. Intraoral 3D Scanning or Dental Impressions for the Assessment of Dental Arch Relationships in Cleft Care: Which is Superior?

    Science.gov (United States)

    Chalmers, E V; McIntyre, G T; Wang, W; Gillgrass, T; Martin, C B; Mossey, P A

    2016-09-01

    This study was undertaken to evaluate intraoral 3D scans for assessing dental arch relationships and obtain patient/parent perceptions of impressions and intraoral 3D scanning. Forty-three subjects with nonsyndromic unilateral cleft lip and palate (UCLP) had impressions taken for plaster models. These and the teeth were scanned using the R700 Orthodontic Study Model Scanner and Trios® Digital Impressions Scanner (3Shape A/S, Copenhagen, Denmark) to create indirect and direct digital models. All model formats were scored by three observers on two occasions using the GOSLON and modified Huddart Bodenham (MHB) indices. Participants and parents scored their perceptions of impressions and scanning from 1 (very good) to 5 (very bad). Intra- and interexaminer reliability were tested using GOSLON and MHB data (Cronbach's Alpha >0.9). Bland and Altman plots were created for MHB data, with each model medium (one-sample t tests, P 0.9) were good for all formats with the direct digital models having the lowest interexaminer differences. Participants had higher ratings for scanning comfort (84.8%) than impressions (44.2%) (P impressions (51.2%) (P > .05). None disliked scanning, but 16.3% disliked impressions. Data for parents and children positively correlated (P 3D scans was superior to indirect digital and to plaster models; Subjects with UCLP preferred intra-oral 3D scanning to dental impressions, mirrored by parents/carers; This study supports the replacement of conventional impressions with intra-oral 3D scans in longitudinal evaluations of the outcomes of cleft care.

  2. Improvement of Diagnostic Accuracy by Standardization in Diuretic Renal Scan

    International Nuclear Information System (INIS)

    Hyun, In Young; Lee, Dong Soo; Lee, Kyung Han; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kim, Kwang Myung; Choi, Hwang; Choi, Yong

    1995-01-01

    We evaluated diagnostic accuracy of diuretic renal scan with standardization in 45 children(107 hydronephrotic kidneys) with 91 diuretic assessments. Sensitivity was 100% specificity was 78%, and accuracy was 84% in 49 hydronephrotic kidneys with standardization. Diuretic renal scan without standardization, sensitivity was 100%, specificity was 38%, and accuracy was 57% in 58 hydronephrotic kidneys. The false-positive results were observed in 25 cases without standardization, and in 8 cases with standardization. In duretic renal scans without standardization, the causes of false-positive results were 10 early injection of lasix before mixing of radioactivity in loplsty, 6 extrarenal pelvis, and 3 immature kidneys of false-positive results were 2 markedly dilated systems postpyeloplsty, 2 etrarenal pevis, 1 immature kidney of neonate , and 2 severe renal dysfunction, 1 vesicoureteral, reflux. In diuretic renal scan without standardization the false-positive results by inadequate study were common, but false-positive results by inadequate study were not found after standardization. The false-positive results by dilated pelvo-calyceal systems postpyeloplsty, extrarenal pelvis, and immature kidneys of, neonates were not dissolved after standardization. In conclusion, diagnostic accuracy of diuretic renal scan with standardization was useful in children with renal outflow tract obstruction by improving specificity significantly.

  3. Reduction of motion artifacts for PET imaging by respiratory correlated dynamic scanning

    International Nuclear Information System (INIS)

    Chuang, K.-S.; Chen, T.-J.; Chang, C.-C.; Wu, J.; Chen, S.; Wu, L.-C.; Liu, R.-S.

    2006-01-01

    Organ motion caused by respiration is a major challenge in positron emission tomography (PET) imaging. This work proposes a technique to reduce smearing in PET imaging caused by respiratory motion. Dynamic scanning at 1 frame/s is used. A point source, used as a marker, is attached to the object's abdomen during the scan. The source position in the projection view moves with respiratory motion and can be used to represent the respiratory phase within the time interval in which each frame data are acquired. One hundred and twenty frames are obtained for each study. The range of the positions of the marker is divided into four groups, representing different respiratory phases. The frames in which the organ positions (phases) are the same summed to produce a static sub-sinogram. Each sub-sinogram then undergoes regular image reconstruction to yield a motion-free image. The technique is applied to one volunteer under both free and coached breathing conditions. A parameter called the volume reduction factor is adopted to evaluate the effectiveness of this motion-reduction technique. The preliminary results indicate that the proposed technique effectively reduces motion artifacts in the image. Coached breathing yields better results than free breathing condition. The advantages of this method are that (1) the scanning time remains the same; (2) free breathing is allowed during the acquisition of the image; and (3) no user intervention is required

  4. CS-Studio Scan System Parallelization

    Energy Technology Data Exchange (ETDEWEB)

    Kasemir, Kay [ORNL; Pearson, Matthew R [ORNL

    2015-01-01

    For several years, the Control System Studio (CS-Studio) Scan System has successfully automated the operation of beam lines at the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and Spallation Neutron Source (SNS). As it is applied to additional beam lines, we need to support simultaneous adjustments of temperatures or motor positions. While this can be implemented via virtual motors or similar logic inside the Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs), doing so requires a priori knowledge of experimenters requirements. By adding support for the parallel control of multiple process variables (PVs) to the Scan System, we can better support ad hoc automation of experiments that benefit from such simultaneous PV adjustments.

  5. Radioisotope indicator, type BETA 2

    International Nuclear Information System (INIS)

    Duszanski, M.; Pankow, A.; Skwarczynski, B.

    1975-01-01

    The authors describe a radioisotope indicator, type BETA 2, constructed in the ZKMPW Works to be employed in mines for counting, checking, signalling the presence and positioning of cars, as well as monitoring the state of some other equipment. (author)

  6. Implementation of dual energy CT scanning

    International Nuclear Information System (INIS)

    Marshall, W.; Hall, E.; Doost-Hoseini, A.; Alvarez, R.; Macovski, A.; Cassel, D.

    1984-01-01

    A prereconstruction method for dual energy (PREDECT) analysis of CT scans is described. In theory, this method can (a) eliminate beam hardening and produce an accuracy comparable with monoenergetic scans and (b) provide the effective atomic number and electron density of any voxel scanned. The implementation proves these statements and eliminates some of the objectionable noise. A phantom was constructed with a cylindrical sleeve-like compartment containing known amounts of high atomic number material simulating a removable skull. Conventional scans, with and without this beam hardener, were done of a water bath containing tubes of high electron and high atomic number material. Dual energy scans were then done for PREDECT. To increase the effective separation of the low and high energy beams by using more appropriate tube filtration, a beam filter changer was fabricated containing erbium, tungsten, aluminum, and steel. Erbium, tungsten, and steel were used at high energy and aluminum, steel, and erbium at low energy for data acquisition. The reconstructions were compared visually and numerically for noise levels with the original steel only filtration. A decrease was found in noise down to approximately one-half the prior level when erbium/aluminum or tungsten/aluminum replaced the steel/steel filter. Erbium and tungsten were equally effective. Steel/erbium and steel/aluminum also significantly reduced image noise. The noise in the photoelectric (P) and Compton (C) images is negatively correlated. At any pixel, if the noise is positive in the P image, it is most probably negative in the C. Using this fact, the noise was reduced by postreconstruction processing

  7. 67Ga scanning and upper gastrointestinal series for gastric lymphomas

    International Nuclear Information System (INIS)

    Ichiya, Y.; Oshiumi, Y.; Kamoi, I.; Imoto, T.; Shimoda, Y.; Kitagawa, S.; Matsuura, K.

    1982-01-01

    67 Ga scanning and upper gastrointestinal (UGI) series were performed in 13 patients with gastric lymphomas before any treatment was initiated. Seven of these patients also underwent both examinations after completing chemotherapy and/or radiation therapy. Prior to treatment, all 13 patients had abnormalities on the UGI examination, and 12 of them had abnormalities on the 67 Ga scans. In 6 patients, more extensive gastric abnormalities were demonstrated by 67 Ga scanning than by UGI examination. Although persistent 67 Ga uptake after treatment was indicative of relatively poor therapeutic response, lack of uptake did not always indicate a good response to treatment

  8. Are environmental scanning units effective?

    Science.gov (United States)

    Stubbart, C

    1982-06-01

    Many authorities have urged companies to set up environmental scanning to assist corporate planning. Some advocates have recommended a unit at corporate level. This would give breadth of view and penetration into the future. It would arm decision makers with accurate forecasts. The information would be broad in scope and future directed. It could provide also assumptions for long-range planning. The Fahey and King study produced a model of corporate scanning types. The data showed that environmental information was built into the plan. Though the political environment was important, scanning was inadequate. The best location for scanning was not at corporate level and most firms used irregular methods. The Thomas study concluded that effective environmental scanning was permanent and multi level and that 'best practice' was continuous scanning. In 1978 the sample organizations were revisited. Five of the twelve have not changed their practice. The factors which encouraged a continuous model were the attitudes of academics and business media, demonstrated success of the units, the right kind of personnel. Contrary influences were changes in top management, decentralization moves, resource cuts, defining the environment and its significance, the availability of scanning competent personnel, surprise itself, and the availability of alternatives e.g. external forecasts.

  9. Re-scan confocal microscopy: scanning twice for better resolution.

    Science.gov (United States)

    De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.

  10. Positional games

    CERN Document Server

    Hefetz, Dan; Stojaković, Miloš; Szabó, Tibor

    2014-01-01

    This text serves as a thorough introduction to the rapidly developing field of positional games. This area constitutes an important branch of combinatorics, whose aim it is to systematically develop an extensive mathematical basis for a variety of two-player perfect information games. These range from such popular games as Tic-Tac-Toe and Hex to purely abstract games played on graphs and hypergraphs. The subject of positional games is strongly related to several other branches of combinatorics such as Ramsey theory, extremal graph and set theory, and the probabilistic method. These notes cover a variety of topics in positional games, including both classical results and recent important developments. They are presented in an accessible way and are accompanied by exercises of varying difficulty, helping the reader to better understand the theory. The text will benefit both researchers and graduate students in combinatorics and adjacent fields.

  11. Complementary role of CT and In-111 leukocyte scans in the diagnosis of infected hematoma and thrombosis

    International Nuclear Information System (INIS)

    Kim, E.E.; Pjura, G.A.; Floyd, W.; Raval, B.; Sandler, C.; Gobuty, A.H.

    1984-01-01

    Patients with traumatic hematomas or those with indwelling catheters who subsequently develop fever and sepsis without clinical localizing signs to indicate an inflammatory focus can present a diagnostic dilemma. Early diagnosis of an infected hematoma or thrombus is important to optimal management. CT can provide, exquisite delineation of anatomy identifying and localizing a post-traumatic fluid collection but cannot reliably distinguish hematoma from abscess in all cases. A thrombus at a catheter tip may be too small to be resolved; when identified, the question of infection again remains. In-111 leukocyte scanning provides a method for identifying or ruling out infection in these situations. The authors performed In-111 leukocyte scans on 15 patients with indwelling catheters. Five of these patients were febrile with positive blood cultures. In-111 leukocyte scans showed positive findings in 8 patients: 5 showed surgically confirmed infected hematomas in the abdomen (3 in the pelvis, 1 in a kidney, 1 in the splenic bed), and 3 showed infected thrombosis in catheter tips. The authors conclude that CT scanning and In-111 leukocyte scanning play complementary roles in the evaluation of traumatic hematomas and thrombosis, the former providing precise anatomic delineation and the latter providing evidence of inflammation

  12. Scanning by use of TV

    International Nuclear Information System (INIS)

    Drevermann, H.

    1981-01-01

    The use of TV read out for scanning and measuring holographic pictures seems to give less problems than the use of optical projection as is usual for conventional bubble chamber photos. Whereas the measuring of conventional bubble chamber pictures seems to give no problems, it is not clear whether scanning by use of TV is possible. Therefore scanning pictures from experiment NA16 (taken in LEBC) with TV only was tried using the TV system of ERASME, where the CRT system is used as a camera. It should be mentioned that this system, being a flying spot device, cannot be adapted for holography. (author)

  13. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  14. Researcher Positioning

    DEFF Research Database (Denmark)

    Khawaja, Iram; Mørck, Line Lerche

    2009-01-01

    involvement by the researcher, which challenges traditional perspectives onresearch and researcher positioning. A key point in this regard is the importance ofconstant awareness of and reflection on the multiple ways in which one's positioningas a researcher influences the research process. Studying the other...

  15. Position detector

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1985-01-01

    Purpose: To enable to detect the position of an moving object in a control rod position detector, stably in a digital manner at a high accuracy and free from the undesired effects of circumstantial conditions such as the reactor temperature. Constitution: Coils connected in parallel with each other are disposed along the passage of a moving object and variable resistors and relays are connected in series with each of the coils respectively. Light emitting diodes is connected in series with the contacts of the respective relays. The resistance value of the variable resistors are adjusted depending on the changes in the circumstantial conditions and temperature distribution upon carrying out the positional detection. When the object is inserted into a coils, the relevant relay is deenergized, by which the relay contacts are closed to light up the diode. In the same manner, as the object is successively inserted into the coils, the diodes are lighted-up successively thereby enabling highly accurate and stable positional detection in a digital manner, free from the undesired effects of the circumstantial conditions. (Horiuchi, T.)

  16. Security scanning at 35 GHz

    Science.gov (United States)

    Anderton, Rupert N.; Appleby, Roger; Coward, Peter R.; Kent, P. J.; Price, Sean; Sinclair, Gordon N.; Wasley, Matthew R. M.

    2001-08-01

    It has been known for some time that millimeter waves can pas through clothing. In short range applications such as in the scanning of people for security purposes, operating at Ka band can be an advantage. The penetration through clothing is increased and the cost of the equipment when compared to operation at W band. In this paper a Ka band mechanically scanned imager designed for security scanning is discussed. This imager is based on the folded conical scan technology previously reported. It is constructed from low cost materials such as polystyrene and printed circuit board. The trade off between image spatial resolution and the number of receivers will be described and solutions, which minimize this number discussed.

  17. Scanning Tunneling Microscopy - image interpretation

    International Nuclear Information System (INIS)

    Maca, F.

    1998-01-01

    The basic ideas of image interpretation in Scanning Tunneling Microscopy are presented using simple quantum-mechanical models and supplied with examples of successful application. The importance is stressed of a correct interpretation of this brilliant experimental surface technique

  18. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  19. Dynamic Flaps Electronic Scan Antenna

    National Research Council Canada - National Science Library

    Gonzalez, Daniel

    2000-01-01

    A dynamic FLAPS(TM) electronic scan antenna was the focus of this research. The novelty S of this SBIR resides in the use of plasma as the main component of this dynamic X-Band phased S array antenna...

  20. Is pruritus an indicator of aquaporin-positive neuromyelitis optica?

    Science.gov (United States)

    Netravathi, Manjunath; Saini, Jitender; Mahadevan, Anita; Hari-Krishna, Bollampalli; Yadav, Ravi; Pal, Pramod Kumar; Satishchandra, Parthasarathy

    2017-05-01

    Recently, pruritus has been recognised as an important association with neuromyelitis optica spectrum disorders (NMOSD). To determine the clinical and radiological characteristics of patients with NMOSD and pruritus. Among 57 consecutive patients with NMOSD, 15 (26.3% women) reported pruritus. All had aquaporin-4 (AQP4) antibodies. The mean age was 34.5 ± 9.1 years, age at onset was 31.3 ± 11.0 years and the duration of illness was 3.9 ± 3.1 years. Pruritus preceded the neurological disturbances in all the patients. Predominant patients experienced pruritus in the cervical dermatome (66.7%) followed by cervicothoracic region (13.3%), trigeminal nerve (13.3%) and lumbar region (6.7%). Lesions extending from cervicomedullary junction up to the thoracic segment was the most common site of affection (40%) followed by cervicothoracic (26.7%), cervicomedullary junction to cervical cord (13.3%), cervical cord (6.7%) and thoracic segment (6.7%). This report is one of the largest series reporting the close association of pruritus with onset of neurological symptoms in NMOSD. It highlights the importance of recognising this rare symptom which may help in making a correct diagnosis in a patient with suspected demyelinating disorder. In a patient with NMOSD, early treatment with immunomodulation during pruritus may prevent or minimise occurrence of neurological dysfunction.