Sample records for portable radiation survey

  1. Portable radiation monitors

    International Nuclear Information System (INIS)

    Masui, Kaoru; Ishikura, Takeshi; Inui, Daisuke

    2007-01-01

    This paper presents an overview of typical portable radiation monitors and introduces Fuji Electric's latest models. The overview describes the types, uses and performance of ion chamber survey meters, GM survey meters and neutron ambient dose equivalent rate meters. Fuji Electric's new model of a wide-energy-range X/gamma ray survey meter which measures low energy X-rays up to 8 keV, a battery-powered environmental dosemeter system which measures dose history and is capable of continuous measurement with batteries over a year, and a portable monitoring post which measures dose rates from background to 10 8 nGy/h and transmits data by cellular phone are introduced, and their specifications and performance are described. (author)

  2. Wide Range Portable Radiation Survey Meter for Emergency Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gangadharan, P.; Bhave, D. G.; Gokarn, R. S.; Khadake, R. G. [Directorate Of Radiation Protection, Bhabha Atomic Research Centre, Trombay, Bombay (India)

    1969-05-15

    The paper describes a portable battery-operated radiation survey meter for monitoring a wide range of X- and gamma-ray exposure rates from 1 mR/h to 100 R/h. The instrument Incorporates a halogen GM tube as the detector and a count-rate meter for indication. A transistorized d.c. -d.c. converter supplies the necessary high voltage to the GM counter. The instrument response has been made energy independent in the energy range 80 keV to 1.25 MeV. Further, the response is linear over the entire range of exposure rates. Suitable extension rods have been designed to provide sufficient separation between the probe and the meter in cases where remote monitoring is necessary because of high fields. (author)

  3. Portable radiation detector and mapping system

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Hayes, D.W.; Eakle, R.F.

    1995-01-01

    A portable radiation detector and mapping system (RADMAPS) has been developed to detect, locate and plot nuclear radiation intensities on commercially available digital maps and other images. The field unit records gamma-ray spectra or neutron signals together with positions from a Global Positioning System (GPS) on flash memory cards. The recorded information is then transferred to a lap-top computer for spectral data analyses and then georegistered graphically on maps, photographs, etc. RADMAPS integrates several existing technologies to produce a preprogrammable field unit uniquely suited for each survey, as required. The system presently records spectra from a Nal(Tl) gamma-ray detector or an enriched Li-6 doped glass neutron scintillator. Standard Geographic Information System software installed in a lap-top, complete with CD-ROM supporting digitally imaged maps, permits the characterization of nuclear material in the field when the presence of such material is not otherwise documented. This paper gives the results of a typical site survey of the Savannah River Site (SRS) using RADMAPS

  4. RAM R-200 - A Portable Ruggedized Radiation Monitoring System

    International Nuclear Information System (INIS)

    Wengrowicz, U.; Mazor, T.; Assido, H.; Kadmon, Y.; Tirosh, D.; Shani, G.

    1999-01-01

    RAM R-200, a new generation of ruggedized portable radiation-monitoring systems, is presented. The system which is a result of interdisciplinary research, was developed at the NRCN in collaboration with Ben-Gurion University. It consists of RAM R-200 - a portable radiation meter, and a variety of external probes for wide range gamma radiation fields and beta-gamma contamination detection and measurement. The meter or each one of the external probes can be used as a portable system or a stand-alone radiation measurement station. All the system's components were specially designed to meet severe environmental conditions

  5. Development of custom LCD based portable survey/contamination monitors

    International Nuclear Information System (INIS)

    Reddy, J.D.

    2010-01-01

    Equipments for carrying out radiation survey measurements for alpha, beta and gamma radiations have evolved considerably with the advancements in Electronics overtime. There are 2 major classes of portable instruments available from most manufacturers - (a) Analog indicator type (b) Direct digital readout type. Analog meters give a direct quantifying feel to radiation levels though they are not rich features nor they have smartness like a digital meter. Digital versions have advantages of direct readout numerically and configurable as per users requirements. To achieve best features of both the techniques a dual indicator type LCD module comprising of Analog indicating LCD segments and digital readout indicating 7 segments has been developed. This LCD comprising of LCD glass and its display driver has been deployed across various types of survey meters and contamination monitors manufactured by Nucleonix. This display now facilitates direct readout of dose rate/count rate in various units simultaneously in both analog LCD scale and direct digital indication. (author)

  6. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  7. Telepositional portable real time radiation monitoring system

    International Nuclear Information System (INIS)

    Talpalariu, Jeni; Matei, Corina; Popescu, Oana

    2010-01-01

    Technology development for complex portable networks is on going to meet the area dosimetry challenge, improving the basic design using new telepositional GPS satellite methods and GSM terrestrial civil radio transmission networks. The system and devices proposed overcome the limitations of fixed and portable dosimeters, providing wireless real time radiations data and geospatial information's means, using many portable dosimeter stations and a mobile dosimeter computerised central console. (authors)

  8. Development of new portable radiation counters for promotion of better understanding of radiation by the public

    International Nuclear Information System (INIS)

    Tanabe, Hiroshi

    1995-01-01

    This study aims to promote the correct understanding of radiation to the public. All the questions asked by participants at forums held in Aomori, where commercial nuclear fuel cycle facilities are planned, were studied. More than half of these questions were concerned about radiation hazards. Measurements, using radiation counters at the meeting, provided the most effective means of explanation about radiation hazards to the public. For this purpose, portable β- and α-ray counters, being able to detect small amounts of radioactive substances around us, were developed. Each new counter is easily handled, is light-weight (about 10-20% that of domestic survey meters) and inexpensive (about 20-25% the price). The methods used to explain radiation with both counters have been also studied. This explanation has provided the public with a better understanding of the nature and hazards of radiation on human health than the former methods using textbooks. (author)

  9. Portable neutron and gamma-radiation instruments

    International Nuclear Information System (INIS)

    Murray, W.S.; Butterfield, K.B.

    1990-01-01

    This paper reports on the design and building of a smart neutron and gamma-radiation detection systems with embedded microprocessors programmed in the FORTH language. These portable instruments can be battery-powered and can provide many analysis functions not available in most radiation detectors. Local operation of the instruments is menu-driven through a graphics liquid crystal display and hex keypad; remote operation is through a serial communications link. While some instruments simply count particles, others determine the energy of the radiation as well as the intensity. The functions the authors have provided include absolute source-strength determination. Feynmann variance analysis, sequential-probability ratio test, and time-history recording

  10. Portable Radiation Package (PRP) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, R Michael [Remote Measurements and Research Company, Seattle, WA (United States)

    2017-08-03

    The Portable Radiation Package (PRP) was developed to provide basic radiation information in locations such as ships at sea where proper exposure is remote and difficult, the platform is in motion, and azimuth alignment is not fixed. Development of the PRP began at Brookhaven National Laboratory (BNL) in the mid-1990s and versions of it were deployed on ships in the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Nauru-99 project. The PRP was deployed on ships in support of the National Aeronautics and Space Administration (NASA) Sensor Intercomparison for Marine Biological and Interdisciplinary Ocean Studies (SIMBIOS) program. Over the years the measurements have remained the same while the post-processing data analysis, especially for the FRSR, has evolved. This document describes the next-generation Portable Radiation Package (PRP2) that was developed for the DOE ARM Facility, under contract no. 9F-31462 from Argonne National Laboratory (ANL). The PRP2 has the same scientific principles that were well validated in prior studies, but has upgraded electronic hardware. The PRP2 approach is completely modular, both in hardware and software. Each sensor input is treated as a separate serial stream into the data collection computer. In this way the operator has complete access to each component of the system for purposes of error checking, calibration, and maintenance. The resulting system is more reliable, easier to install in complex situations, and more amenable to upgrade.

  11. ANOLE Portable Radiation Detection System Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Hodge, Chris A.

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  12. Portable radiation meters evaluation in high rates of air kerma

    International Nuclear Information System (INIS)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Vivolo, Vitor

    2015-01-01

    A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established, specifying their sensitivities and operating characteristics. Applied tests were: reading equipment variation with battery voltage, geotropism effect, energy dependence, the angular dependence and overload. Thus it was possible to determine the most common characteristic found in these equipment (quality control programs). The behavior of 17 portable meters was analyzed and in this study, 10 of them have been tested. It was performed to characterize the gamma irradiating system (radiation dosimetry field) that possesses higher activity in teletectors for testing of larger measuring range. New calibration criteria were established following international recommendations. Therefore, it was made the improvement of the quality control programme of portable meters of ionizing radiation high rates of air kerma calibration laboratory, benefiting the users of such equipment with better consistent calibration measurements. (author)

  13. Survey of environmental radiation dose rates in Tokushima prefecture

    International Nuclear Information System (INIS)

    Sakama, Minoru; Imura, Hiroyoshi; Akou, Natsuki; Takeuchi, Emi; Morihiro, Yukinori

    2004-01-01

    Survey of environmental radiation dose rates in Tokushima prefecture has been carried out using a portable NaI (Tl) scintillation survey meter and a CsI(Tl) pocket type one. To our knowledge, previous several surveys in Tokushima, for example by Abe et al. (1982) and Yoshino et al. (1991), have remained to report the environmental radiation dose rates merely about the major cities, that is Tokushima City and others along the Pacific. Up to now, there have been few efforts to survey the environmental radiation dose rates about mountain valleys in Tokushima. In this work, it is remarkable that we have for the first time made surveys of environmental radiation dose rates on the 6 routes across the Sanuki mountains and inside the pier of Onaruto Bridge, 'Naruto Uzu-no-michi', in the northern area of Tokushima. In the course of present surveys, the maximum value of the environmental radiation dose rates was 0.117±0.020 μGy/h at Higetouge in Sanuki City, and then it was found that the radiation dose rates across the Sanuki mountains tend to increase slightly with approaching Kagawa area from Tokushima one. Considering geological formation around the northern side of Sanuki mountains, there are mainly geological layers of granodiorite containing in the substantial amount of naturally occurring radionuclides, 40 K, U-series, and Th-series, than other geological rocks and it was found that the terrestrial gamma-rays have effect on the environmental radiation dose rates according to the geological formation. (author)

  14. Portable Wind Energy Harvesters for Low-Power Applications: A Survey.

    Science.gov (United States)

    Nabavi, Seyedfakhreddin; Zhang, Lihong

    2016-07-16

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

  15. The reduction methods of operator's radiation dose for portable dental X-ray machines.

    Science.gov (United States)

    Cho, Jeong-Yeon; Han, Won-Jeong

    2012-08-01

    This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

  16. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

    OpenAIRE

    Seyedfakhreddin Nabavi; Lihong Zhang

    2016-01-01

    Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechan...

  17. Portable Wind Energy Harvesters for Low-Power Applications: A Survey

    Directory of Open Access Journals (Sweden)

    Seyedfakhreddin Nabavi

    2016-07-01

    Full Text Available Energy harvesting has become an increasingly important topic thanks to the advantages in renewability and environmental friendliness. In this paper, a comprehensive study on contemporary portable wind energy harvesters has been conducted. The electrical power generation methods of portable wind energy harvesters are surveyed in three major groups, piezoelectric-, electromagnetic-, and electrostatic-based generators. The paper also takes another view of this area by gauging the required mechanisms for trapping wind flow from ambient environment. In this regard, rotational and aeroelastic mechanisms are analyzed for the portable wind energy harvesting devices. The comparison between both mechanisms shows that the aeroelastic mechanism has promising potential in producing an energy harvester in smaller scale although how to maintain the resonator perpendicular to wind flow for collecting the maximum vibration is still a major challenge to overcome for this mechanism. Furthermore, this paper categorizes the previously published portable wind energy harvesters to macro and micro scales in terms of their physical dimensions. The power management systems are also surveyed to explore the possibility of improving energy conversion efficiency. Finally some insights and research trends are pointed out based on an overall analysis of the previously published works along the historical timeline.

  18. Use of rechargeable nickel-cadmium batteries for portable radiation monitors

    International Nuclear Information System (INIS)

    Zaman, M.Q.

    1987-08-01

    An effort was taken to assess the chargers available at the local market and the use of rechargeable batteries in the portable radiation monitors. This report is a very brief description of the study and observations. In order to have fair and justified conclusions regarding the use of Ni-Cd battery in portable instruments, many criterions have to be considered which takes very long observations under some specified conditions. This report is a combination of previous experimental results by scientists, data supplied by the manufacturers and short time observations in Seibersdorf Laboratory. The report has three parts (a) comparison of the ordinary battery with the rechargeables (b) selection of a suitable charger and (c) probability of application of the Ni-Cd battery in portable dosimeters

  19. External radiation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site.

  20. External radiation surveillance

    International Nuclear Information System (INIS)

    Antonio, E.J.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report describes how external radiation was measured, how surveys were performed, and the results of these measurements and surveys. External radiation exposure rates were measured at locations on and off the Hanford Site using thermoluminescent dosimeters (TLD). External radiation and contamination surveys were also performed with portable radiation survey instruments at locations on and around the Hanford Site

  1. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  2. Application of solid dosimeter to radiation control

    International Nuclear Information System (INIS)

    Tsujimoto, Tadashi

    1988-01-01

    Individual exposure dose measuring devices are used to measure the dose of each person in facilities using radiations. Major devices of this type currently used in Japan include the film badge, thermoluminescence dosimeter, portable radiation dosimeter and fluorescent glass dosimeter. All of these devices except the portable radiation dosimeter are of a solid type. Various portable-type spatial dose rate measuring devices, generally called survey meters, are available to determine the spatial distribution of radiations. Major survey meters incorporates an ionization chamber, GM counter tube or scintillation counter, while BF 3 counting tubes are available for neutron measurement. Of these, the scintillation dosimeter is of a solid type. A new scintillation survey meter has recently been developed which incorporated a discrimination bias modulation circuit. Dosimeters incorporating an ionization chamber or a GM counter tube are generally used as portable alarms. Recently, a new solid-type alarm has been developed which incorporates a solicon radiation detector. Microcomputers are also used for self-diagnosis, data processing, automatic calibration, etc. (Nogami, K.)

  3. Portable radiation meters developed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Sobajic, V.; Smelcerovic, M.

    1989-01-01

    Portable meters designed for X and gamma radiation measurements and beta detection are described. An instrument using ionization chamber is developed with new type of electrometer amplifier. It is designed for precise and reliable exposure and exposure rate measurements. Another instrument with GM counters covers 8 linear ranges: from background up to 10 Sv/h. Some specific solutions and basic measurement characteristics of these instruments are presented (author)

  4. A national survey of occupational radiation exposure among diagnostic radiologic technologists in South Korea

    International Nuclear Information System (INIS)

    Lee, Jeeyoung; Cha, Eun Shil; Jeong, Meeseon; Lee, Won Jin

    2015-01-01

    The objective of this study was to investigate representative occupational characteristics and radiation exposure for South Korean radiologic technologists. The authors conducted a national survey by stratified sampling of South Korean administrative districts and types of medical facilities. A total of 585 technologists were surveyed, and survey data were linked with dosimetry data from the National Dose Registry. A total of 73 % of radiologic technologists sampled were male, 62 % were younger than age 40 and 86.5 % began employment after 1990. The most frequent practices among radiologic technologists were diagnostic routine X-ray followed by computed tomography (CT) and portable X-ray. Male workers were more frequently involved in CT, portable X-ray and interventional radiology whereas female workers carried out most mammography procedures. The average annual effective dose was 2.3 mSv for male and 1.3 mSv for female workers. The dose was significantly higher for workers in the provinces and those who had recently started work. (authors)

  5. ''Cutie Pie,'' A portable radiation instrument

    International Nuclear Information System (INIS)

    Ballou, C.O.

    1947-01-01

    A portable beta and gamma radiation meter of exceedingly small dimensions and weight has been developed. User acceptance has been more enthusiastic than any previous instrument of its type. The circuit, using one Victoreen V-32 tube, is the simplest electronic circuit possible for radiation work and gives high sensitivity. Stability exceeds anything of comparable sensitivity which has come to our attention. The short term stability is due to a circuit which prevents emission before the cathode reaches operating temperature. Long term stability has been improved by evacuating the tube enclosure and switch. The complete, one unit instrument, weighs four pounds two ounces, and is carried with a pistol grip. Exclusive of chamber and handle, its dimensions are 3'' wide, 6 1/2'' long, and 5'' high. The case is formed of aluminum and is designed to give excellent visibility of the meter. Three ranges of approximately 50, 500 and 5000 mr/hr have been incorporated in the instruments. The instrument has been named ''Cutie Pie'' due to its diminutive size

  6. DIAPHANE: A portable radiation transport library for astrophysical applications

    Science.gov (United States)

    Reed, Darren S.; Dykes, Tim; Cabezón, Rubén; Gheller, Claudio; Mayer, Lucio

    2018-05-01

    One of the most computationally demanding aspects of the hydrodynamical modelingof Astrophysical phenomena is the transport of energy by radiation or relativistic particles. Physical processes involving energy transport are ubiquitous and of capital importance in many scenarios ranging from planet formation to cosmic structure evolution, including explosive events like core collapse supernova or gamma-ray bursts. Moreover, the ability to model and hence understand these processes has often been limited by the approximations and incompleteness in the treatment of radiation and relativistic particles. The DIAPHANE project has focused on developing a portable and scalable library that handles the transport of radiation and particles (in particular neutrinos) independently of the underlying hydrodynamic code. In this work, we present the computational framework and the functionalities of the first version of the DIAPHANE library, which has been successfully ported to three different smoothed-particle hydrodynamic codes, GADGET2, GASOLINE and SPHYNX. We also present validation of different modules solving the equations of radiation and neutrino transport using different numerical schemes.

  7. Development of semiconductor radiation sensors for portable alarm-dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. K.; Moon, B. S.; Chung, C. E.; Hong, S. B.; Kim, J. Y.; Kim, J. B.; Han, S. H.; Lee, W. G. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-01-01

    We studied Semiconductor Radiation Sensors for Portable Alarm-Dosimeter. We calculated response functions for gamma energy 0.021, 0.122, 0.662, 0.835, 1.2 MeV using EGS4 codes. When we measured at various distance from source to detector, the detection efficiency of Si semiconductor detector was better than that of GM tube. The linear absorption coefficients of steel and aluminum plate were measured. These experimental results of the response of detector for intensity of radiation field coincide to the theoretical expectation. The count value of Si detector was changed with changing thickness of steel as changing threshold voltage of discriminator, and the linear absorption coefficient increased with increasing threshold voltage. Radiation detection efficiency shows difference at each threshold voltage condition. This results coincided to the theoretical simulation. 33 refs., 27 figs., 8 tabs. (Author)

  8. Portable dosimeter

    International Nuclear Information System (INIS)

    Buffa, A.; Caley, R.; Pfaff, K.

    1986-01-01

    A simple but very accurate portable dosimeter is described for indicating the intensity of ionizing radiation, comprising, as a unit: (a) a radiation-detection chamber having a pair of parallel, facing, electrically-conducting, radiation-permeable electrodes spaced from each other to define a volume for a gas which is ionized by the radiation when exposed thereto; (b) electric potential supply means connected across the electrodes for attracting the gas ions to the electrodes and transferring their charge to the electrodes; (c) detection circuit means connected across the electrodes and having at least one of high-frequency electromagnetic- and radiation-sensitive components for detecting the charge on the electrodes and indicating therefrom a representation of the intensity of the radiation; (d) radiation shield means surrounding the radiation-sensitive components of the detection circuit means for shielding the latter from the ionizing radiation; (e) electric shield means surrounding the sensitive components of the detection circuit means for shielding the latter from electromagnetic interference including any caused by the ionizing radiation; and (f) ion shield means potting the ion-sensitive components for shielding them from radiation-caused ambient ionization; whereby the entire dosimeter may be assembled as the unit and portably transported into various radiation sources

  9. Dosimeter Corporation of America portable survey meter type 3795 ''true blue''

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1981-01-01

    This battery-powered, portable exposure Ratemeter covers the range from 0.1 - 100 mR h -1 . It is designed to measure X- and gamma radiation over the energy range 10 keV to 2 MeV and also to detect alpha and beta radiation. The detector is a thin end-window Geiger Muller tube. It is concluded that the instrument has a useful sensitivity to low photon energies and low exposure rates, a reasonable dynamic range and good polar responses, but that a better energy response would be expected above 50 keV. The general standard of design and construction was found to be good. (U.K.)

  10. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  11. Environmental radiation data, 7

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Sakamoto, Ryuichi; Saito, Kimiaki; Tsutsumi, Masahiro; Moriuchi, Shigeru

    1989-10-01

    The Environmental Radiation Physics Laboratory has conducted a large number of background radiation surveys in these years, aiming at the analysis of characteristics and behaviour of environmental radiation, the development of measurement techniques and instruments of environmental radiation, and the evaluation of environmental radiation dose. The environmental radiation data obtained by these surveys are useful for broad purposes as actual survey data. Therefore, it is desirable to make the recording media and the FORMAT of these data available for usual computers. In the light of this circumstance, these data were rearranged and recompiled systematically to meet the demand. This report mentions about the data obtained by the background radiation surveys in and around Tokyo performed during 1982 - 1988 using portable instruments, as well as the information necessary for the data handling. (author)

  12. A historical review of portable health physics instruments and their use in radiation protection programs at Hanford, 1944 through 1988

    Energy Technology Data Exchange (ETDEWEB)

    Howell, W.P.; Kenoyer, J.L.; Kress, M.L.; Swinth, K.L.; Corbit, C.D.; Zuerner, L.V.; Fleming, D.M.; DeHaven, H.W.

    1989-09-01

    This historical review covers portable health physics instruments at Hanford from an applications viewpoint. The review provides information on specific instruments and on the general kinds of facility work environments in which the instruments have been and are being used. It provides a short, modestly technical explanation of the types of nuclear radiations, the way radiation units are quantified, and the types of nuclear radiations, the way radiation units are quantified, and the types of detection media used in portable health physics instruments. This document does not, however, cover the history of the entire Hanford program that was required to develop and/or modify the subject instruments. 11 refs., 34 figs., 2 tabs.

  13. A historical review of portable health physics instruments and their use in radiation protection programs at Hanford, 1944 through 1988

    International Nuclear Information System (INIS)

    Howell, W.P.; Kenoyer, J.L.; Kress, M.L.; Swinth, K.L.; Corbit, C.D.; Zuerner, L.V.; Fleming, D.M.; DeHaven, H.W.

    1989-09-01

    This historical review covers portable health physics instruments at Hanford from an applications viewpoint. The review provides information on specific instruments and on the general kinds of facility work environments in which the instruments have been and are being used. It provides a short, modestly technical explanation of the types of nuclear radiations, the way radiation units are quantified, and the types of nuclear radiations, the way radiation units are quantified, and the types of detection media used in portable health physics instruments. This document does not, however, cover the history of the entire Hanford program that was required to develop and/or modify the subject instruments. 11 refs., 34 figs., 2 tabs

  14. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  15. Development of a Miniaturized and Portable Methane Analyzer for Natural Gas Leak Walking Surveys

    Science.gov (United States)

    Huang, Y. W.; Leen, J. B.; Gupta, M.; Baer, D. S.

    2016-12-01

    Traditional natural gas leak walking surveys have been conducted with devices that are based on technologies such as flame ionization detector (FID), IR-based spectrometer and IR camera. The sensitivity is typically on the ppm level. The low sensitivity means the device cannot pick up leaks far from it, and more time is spent surveying the area before pinpointing the leak location. A miniaturized methane analyzer has been developed to significantly improve the sensitivity of the device used in walking surveys to detect natural gas leaks at greater distance. ABB/LGR's patented Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) is utilized to offer rugged and highly sensitive methane detection in a portable package. The miniaturized package weighs 13.5 lb, with a 4-hour rechargeable battery inside. The precision of the analyzer for methane is 2 ppb at 1 second. The analyzer operates at 10 Hz and its flow response time is 3 seconds for measurements through a 1-meter long sampling wand to registering on the data stream. The data can be viewed in real-time on a tablet or a smartphone. The compact and simplified package of the methane analyzer allows for more efficient walking surveys. It also allows for other applications that require low-power, low-weight and a portable package. We present data from walking surveys to demonstrate its ability to detect methane leaks.

  16. The Performance Assessment of the Detector for the Portable Environmental Radiation Distribution Monitoring System with Rapid Nuclide Recognition

    International Nuclear Information System (INIS)

    Lee, Uk Jae; Kim, Hee Reyoung

    2015-01-01

    The environment radiation distribution monitoring system measures the radiation using a portable detector and display the overall radiation distribution. Bluetooth and RS-232 communications are used for constructing monitoring system. However RS-232 serial communication is known to be more stable than Bluetooth and also it can use the detector's raw data which will be used for getting the activity of each artificial nuclide. In the present study, the detection and communication performance of the developed detector with RS-232 method is assessed by using standard sources for the real application to the urban or rural environment. Assessment of the detector for the portable environmental radiation distribution monitoring system with rapid nuclide recognition was carried out. It was understood that the raw data of detector could be effectively treated by using RS-232 method and the measurement showed a good agreement with the calculation within the relative error of 0.4 % in maximum

  17. The Performance Assessment of the Detector for the Portable Environmental Radiation Distribution Monitoring System with Rapid Nuclide Recognition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Uk Jae; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2015-05-15

    The environment radiation distribution monitoring system measures the radiation using a portable detector and display the overall radiation distribution. Bluetooth and RS-232 communications are used for constructing monitoring system. However RS-232 serial communication is known to be more stable than Bluetooth and also it can use the detector's raw data which will be used for getting the activity of each artificial nuclide. In the present study, the detection and communication performance of the developed detector with RS-232 method is assessed by using standard sources for the real application to the urban or rural environment. Assessment of the detector for the portable environmental radiation distribution monitoring system with rapid nuclide recognition was carried out. It was understood that the raw data of detector could be effectively treated by using RS-232 method and the measurement showed a good agreement with the calculation within the relative error of 0.4 % in maximum.

  18. Vehicle-borne survey techniques for background radiations

    International Nuclear Information System (INIS)

    Minato, Susumu

    1995-01-01

    This paper presented methods for converting count rates measured inside cars and trains in the natural environment into outdoor terrestrial gamma-ray dose rates. First, (1) the method of calibration for a survey meter is described to be applicable to various geological terrains. Next, the regression formulas were acquired experimentally to correct (2) the shielding effects of cars and trains, and (3) the influence of pavements and ballasts. Furthermore, (4) a new method for removing interfering radiation components emitted from cliffs and tunnels was proposed, and the errors in the calculations were evaluated with numerical experiments. In addition, the degree of influence from the cliff was represented with the angle of elevation subtended to the detector. For the items (2)-(4), in particular, it could be explained with simple models that those methods are reasonable. The method for evaluating simply and accurately cosmic-ray dose rates by means of a portable barometer was also described. (author)

  19. Manual for the Portable Handheld Neutron Counter (PHNC) for Neutron Survey and the Measurement of Plutonium Samples

    International Nuclear Information System (INIS)

    Menlove, H.O.

    2005-01-01

    We have designed a portable neutron detector for passive neutron scanning measurement and coincidence counting of bulk samples of plutonium. The counter will be used for neutron survey applications as well as the measurement of plutonium samples for portable applications. The detector uses advanced design 3 He tubes to increase the efficiency and battery operated shift register electronics. This report describes the hardware, performance, and calibration for the system

  20. FPGA-based prototype of portable environmental radiation monitor

    Energy Technology Data Exchange (ETDEWEB)

    Benahmed, A.; Elkarch, H. [CNESTEN -Centre National de l' Energie des Sciences et Techniques Nucleaires (Morocco)

    2015-07-01

    This new portable radiological environmental monitor consists of 2 main components, Gamma ionization chamber and a FPGA-based electronic enclosure linked to convivial software for treatment and analyzing. The HPIC ion chamber is the heart of this radiation measurement system and is running in range from 0 to 100 mR/h, so that the sensitivity at the output is 20 mV/μR/h, with a nearly flat energy response from 0,07 to 10 MEV. This paper presents a contribution for developing a new nuclear measurement data acquisition system based on Cyclone III FPGA Starter Kit ALTERA, and a user-friendly software to run real-time control and data processing. It was developed to substitute the older radiation monitor RSS-112 PIC installed in CNESTEN's Laboratory in order to improve some of its functionalities related to acquisition time and data memory capacity. As for the associated acquisition software, it was conceived under the virtual LabView platform from National Instrument, and offers a variety of system setup for radiation environmental monitoring. It gives choice to display both the statistical data and the dose rate. Statistical data shows a summary of current data, current time/date and dose integrator values, and the dose rate displays the current dose rate in large numbers for viewing from a distance as well as the date and time. The prototype version of this new instrument and its data processing software has been successfully tested and validated for viewing and monitoring the environmental radiation of Moroccan nuclear center. (authors)

  1. New small devices for radiation detection: the Wee Pocket Chirper and the Portable Multichannel Analyzer

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-08-01

    Recent events have demonstrated the need for improved capability to monitor the exposure of workers to radiation and, in general, to identify and measure the many forms of radioactive materials found throughout the nuclear industry. Two radiation monitoring devices have been developed that are much smaller than existing instruments, yet exhibit superior performance and a longer battery life. The first instrument, the Wee Pocket Chirper, is a tiny, battery-powered warning device that chirps when exposed to radiation. The second instrument is a portable battery-powered, computer-based, multichannel analyzer that allows the user to examine radiation fields and to identify the types and amounts of radioactive materials present

  2. Research in radiation monitoring survey instrumentation. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Kennedy, E.J.; Phillips, R.G.; Walker, E.W. Jr.

    1978-01-01

    Two low-power solid-state prototype readout units were developed, an LED display and a LCD display. This display output was in a bar-graph format, covering four-decades of information, with 10-segments per decade. The displays accept a frequency input, which is standardly available from several portable radiation-survey instruments. Both readout units will operate on two D-cell batteries (3.0 Volt), with a typical current drain requirement of 0.3 MA for the LED display and 30μA for the LCD display. A wide-range electrometer circuit was also developed. The circuit covers an input current range from 10 -13 A to 10 -8 A. The output signal is a pulse whose frequency is directly proportional to input current. The circuit requires no high-megohm resistors, and is autoranging. Several candidate input amplifiers were analyzed and evaluated for use with the electrometer circuit

  3. Portable modular detection system

    Science.gov (United States)

    Brennan, James S [Rodeo, CA; Singh, Anup [Danville, CA; Throckmorton, Daniel J [Tracy, CA; Stamps, James F [Livermore, CA

    2009-10-13

    Disclosed herein are portable and modular detection devices and systems for detecting electromagnetic radiation, such as fluorescence, from an analyte which comprises at least one optical element removably attached to at least one alignment rail. Also disclosed are modular detection devices and systems having an integrated lock-in amplifier and spatial filter and assay methods using the portable and modular detection devices.

  4. Environmental radiation data, 9

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Sakamoto, Ryuichi; Saito, Kimiaki; Tsutsumi, Masahiro; Moriuchi, Shigeru

    1993-06-01

    The Environmental Physics Laboratory has conducted a large number of background radiation surveys in these years, aiming at the analysis of characteristics and behaviour of environmental radiation, the development of measurement techniques and instruments of environmental radiation, and the evaluation of environmental radiation dose. As the environmental radiation data obtained by these surveys are useful for broad purposes as actual survey data, it is desirable to arrange these data systematically and to open them to the other scientist. For that, it is necessary to make the recording media and the FORMAT of these data available for usual computers. In the light of this circumstance, these data were rearranged and recompiled systematically to meet the demand. This report mentions about the data obtained by the background radiation surveys in and around Tokyo performed during 1991 - 1993 using portable instruments, as well as the information necessary for the data handling. (author)

  5. Radiation exposure with the NOMAD portable X-ray system.

    Science.gov (United States)

    Goren, A D; Bonvento, M; Biernacki, J; Colosi, D C

    2008-02-01

    A new hand-held battery-operated portable X-ray system was tested for possible leakage radiation through the existing heavy metal compounds surrounding the X-ray tube, backscatter radiation through the lead-filled acrylic shield attached at the end of the exit tube and patient exposure. Dose measurements were conducted using a DXTRR phantom and a water phantom. All measurements were recorded using calibrated thermoluminescent dosimetry (TLD), calibrated Unfors Model 583L dosemeter, and a calibrated Radcal MDH model 1015 dosemeter. The settings for all exposure were 60 kVp, 2.3 mA and 0.25 s using Kodak Insight (Class F) film. All backscatter measurements, in front of the shield, behind the shield, at the finger of the operator, the operator's chest, eyes and gonads were significantly below the maximum permissible radiation leakage as per the United States Food and Drug Administration regulations (100 mR h(-1)). Our measurements indicate that the exposure would be well within the occupational maximum permissible dose for an occupationally exposed person. Film dose was consistent with the manufacturer's recommendations. As a result of our measurements, the State of New York Bureau of Environmental Radiation Protection granted us a variance to use the NOMAD on a case-by-case basis. Our data have shown that the NOMAD presents risks that are no greater than with standard dental radiographic units to the patient or operator and the measured doses are well below recommended levels.

  6. [Experimental research on the electromagnetic radiation immunity of a kind of portable monitor].

    Science.gov (United States)

    Yuan, Jun; Xiao, Dongping; Jian, Xin

    2010-11-01

    The paper is focused on a kind of portable monitor that is widely used in military hospitals. In order to study the electromagnetic radiation immunity of the monitor, the experiments of electromagnetic radiation caused by radio frequency continuous wave in reverberation chamber and by ultra wide band (UWB) electromagnetic pulse have been done. The study results show that UWB electromagnetic pulse interferes observably the operating state of the monitor. It should be paid high attention to take protective measures. The monitor tested has some electromagnetic immunity ability for radio frequency continuous wave radiation. The frequent abnormal phenomena are baseline drift and waveform distortion. The electromagnetic sensitivity of the monitor is related to the frequency of interference source. The monitor tested is most sensitive to the frequency of 390 MHz.

  7. A study on the scattered dose in portable chest radiography

    International Nuclear Information System (INIS)

    Ahn, Bong Seon; Lee, Hwan Hyung

    2000-01-01

    The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. The average of distance of adjacent patients was 219.1 cm at the ward. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it dose not have influence on the adjacent patient. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment

  8. Evaluation of Differences in Response of DOD Portable Instruments and Solid-State Detectors used by MEXT for Measurement of External Radiations with Attention to the Cosmic Radiation Component

    Science.gov (United States)

    2014-03-01

    Defense Threat Reduction Agency 8725 John J. Kingman Road, MS-6201 Fort Belvoir, VA 22060-6201...Attention to the Cosmic Radiation Component DISTRIBUTION A. Approved for public release: distribution is unlimited March 2014...Portable Instruments and Solid-State Detectors used by MEXT for Measurement of External Radiations with Attention to the Cosmic Radiation Component 5a

  9. Radiation Exposure to Staff in Intensive Care Unit with Portable CT Scanner

    Directory of Open Access Journals (Sweden)

    Zhichao Xie

    2016-01-01

    Full Text Available Background. Bedside radiological procedures pose a risk of radiation exposure to ICU staff. The perception of risk may increase the degree of caution among the health care staff and raise new barriers preventing patients from obtaining prompt care. Objective. The aim of this study was to estimate the annual cumulative radiation dose to individual ICU staff. Methods. In this prospective study, forty subjects were required to wear thermoluminescent dosimeter badges during their working hours. The badges were analyzed to determine the exposure after 3 months. Results. A total of 802 radiological procedures were completed at bedside during the study period. The estimated annual dosage to doctors and nurses on average was 0.99 mSv and 0.88 mSv (p<0.001, respectively. Residents were subjected to the highest radiation exposure (1.04 mSv per year, p=0.002. The radiation dose was correlated with day shift working hours (r=0.426; p=0.006 and length of service (r=-0.403; p<0.01. Conclusions. With standard precautions, bedside radiological procedures—including portable CT scans—do not expose ICU staff to high dose of ionizing radiation. The level of radiation exposure is related to the daytime working hours and length of service.

  10. Survey of women's awareness about radiation

    International Nuclear Information System (INIS)

    Onishi, Keiko; Aomi, Yuki; Asada, Kiyoe; Kamiya, Masami; Mitsuishi, Haruko

    2008-01-01

    A project in a voluntary group 'Women's Energy Network' conducted two questionnaire surveys on Japanese women's awareness about radiation. The survey was conducted to investigate how women(non-experts) perceive radiation and radioactivity, what is their image about radiation, to what extent they are aware of the use of radiation in their daily life, and whether they find nuclear related information useful or not. The results of those surveys have led WEN to publish a booklet entitled 'Our Life and Radiation' to be used for public communication and to hold public forums in various cities in Japan. The first survey was conducted in 2001 to those living in big cities such as Tokyo and Osaka and to those living in the area where the nuclear power plant is installed. The response rate was 72.4% (1,028 out of 1,419). The second one was done in 2005 to those living in Tokyo and other big cities. The response rate was 84.7% (888 our of 983). It was derived from the two surveys that they were not so much aware of various applications of radiation for daily use (awareness rate was low), but they considered those information would be useful when it becomes available for them and they were interested in knowing about it. As for the image of radiation, about 80% have shown fear when they see or hear a word 'radiation'. This report provides the result of questionnaire surveys on women's awareness about radiation conducted by 'Our Daily Life and Radiation' project in Women's Energy Network. (author)

  11. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  12. Portable meter study of ionizing radiation Teletector in high rates of air kerma

    International Nuclear Information System (INIS)

    Damatto, Willian Behling; Potiens, Maria da Penha A.; Vivolo, Vitor

    2015-01-01

    A set of portable meters of ionizing radiation high rates of air kerma (teletectors) commonly used in emergencies in Brazil and sent to the Calibration Laboratory of IPEN were under several tests and analyst is parameters for the detectors behavior were established. Applied tests were: energy dependence and primarily overload with the new irradiation system. Thus it was possible to determine the most common characteristic found in these equipment (quality control programs) and new calibration criteria were established following international recommendations. (author)

  13. A portable meteorological station plus nuclear radiation monitoring system using a basic-8052 micro-controller

    International Nuclear Information System (INIS)

    Al-Mohamad, A.; Aghabi, S.; Weiss, C.

    2002-01-01

    a portable meteorology station capable of measuring various atmospheric parameters (mainly ambient temperature, relative humidity, atmospheric pressure, wind speed and direction) was designed and built. The physical quantities were converted to electrical signals using suitable sensors. These signals were then processed and transferred to digital values to be stored in suitable memories. A nuclear radiation alarm system was also built, on the main board, to monitor the nuclear radiation releases levels. The system consists of three main parts: control board, data acquisition board and signals conditioning board. the overall system is controlled by a BASIC-8052 micro-controller. (authors)

  14. Aerial radiation surveys

    International Nuclear Information System (INIS)

    Jobst, J.

    1980-01-01

    A recent aerial radiation survey of the surroundings of the Vitro mill in Salt Lake City shows that uranium mill tailings have been removed to many locations outside their original boundary. To date, 52 remote sites have been discovered within a 100 square kilometer aerial survey perimeter surrounding the mill; 9 of these were discovered with the recent aerial survey map. Five additional sites, also discovered by aerial survey, contained uranium ore, milling equipment, or radioactive slag. Because of the success of this survey, plans are being made to extend the aerial survey program to other parts of the Salt Lake valley where diversions of Vitro tailings are also known to exist

  15. Defining Design Limits of a Portable Radiation Dispersion Prevention System

    Energy Technology Data Exchange (ETDEWEB)

    Kang Seong Woo; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    To the eyes of the general public, however, reducing the chance of such accident is not enough. A typical engineer views a risk as a combination of both consequences and likelihoods, whereas an ordinary person may only consider consequences. The implementations of better regulations, improved human operator actions, and installations of extra safety systems may reduce the chance of having uncontrolled accident practically to zero, yet the public still fears having nuclear reactors. One such barrier system is a portable suction-based radiation dispersion prevention system, called Integrated Portable Suction-Centrifugal Filtration System (IPS-CFS). To design such systems, detailed information about the radioactive source term at the release point to the environment must be available to draw design limits. The preliminary design limits of the IPS-CFS are presented in this paper. It may seem challenging to design a comprehensive radioactive dispersion system that can successfully prevent such extreme accident conditions, especially due to the releases from high pressure. However, as more technologies develop and more realistic source term analyses are performed, it may be possible to develop such a public relief technology. With the development of such technology that can effectively prevent the dispersion of the uncontrolled radioactive releases in case of another Fukushima-like accident, it will result in increased safety of the nuclear power plants for both the public and the workers and may contribute to the increase in the public acceptance of nuclear energy.

  16. Development of a portable monitor for detecting gamma radiation and X-rays

    International Nuclear Information System (INIS)

    Silva Neto, Paulo J. da; Lira, Carlos A.B. de O.; Oliveira, Arno H. de

    2011-01-01

    There are several ways to prevent individuals from receiving excessive or unnecessary doses of radiation, and area monitoring contributes to the radiation protection in the assessment whether these means are really efficient. The area monitoring is used to give an indication of radiation levels in certain locations. Using this method, one can estimate the dose received by staff occupying a particular area for a certain period of time. Hence, the purpose of this work was the construction of a portable monitor, consisting of an ionization chamber, with a volume of approximately 517 cc and built from tissue-equivalent material, and of its associated electronics. Radiation measurements of gamma and X-rays beams were then possible. The results showed a linear response of the monitor for different dose rates. The stability test of the response also showed a good reproducibility within ± 1%. A low energy dependence for energies between 16 - 200keV was observed, and complied well with the IEC 60846 standard. However, for the energy range 200 - 1250keV, the discrepancies to the IEC standard are considerable, so that the interposition of filters is necessary and may improve the energy response curve to within acceptable limits. (author)

  17. Pilot study for natural radiation survey

    International Nuclear Information System (INIS)

    Brown, L.; Driscoll, C.M.H.; Green, B.M.R.; Miles, J.C.H.

    1983-01-01

    NRPB's national survey of natural radiation exposure in homes commenced in 1982 and will run until 1984. A pilot survey was undertaken in over 100 homes for one year, using passive thermoluminescent dosemeters to measure external radiation from terrestrial and cosmic sources and passive radon dosemeters to measure the radon-222 gas concentration. A preliminary analysis of the results obtained from the pilot survey is given. The main value of the pilot survey was in providing experience and various administrative and scientific procedures have been simplified or automated for the national survey. (U.K.)

  18. Victoreen panoramic 470 A survey meter

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-07-01

    This instrument is a portable, battery powered, survey meter covering an exposure rate range from 0 to 1000 R h -1 . and an exposure range of 0 to 1000 mR. It is designed to measure X- and γ-radiation over a wide range of energies and angular distributions, and also to detect alpha and beta radiation. The radiation detector is an unsealed ionisation chamber. The report describes the instrument under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  19. WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

    Energy Technology Data Exchange (ETDEWEB)

    McFadden, C; Flint, D; Grosshans, D; Sawakuchi, G [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Sadetaporn, D [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Rice University, Houston, TX (United States); Asaithamby, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam

  20. WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

    International Nuclear Information System (INIS)

    McFadden, C; Flint, D; Grosshans, D; Sawakuchi, G; Sadetaporn, D; Asaithamby, A

    2016-01-01

    Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm 2 (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line

  1. WE-F-209-02: Radiation Safety Surveys of Linear Accelerators

    International Nuclear Information System (INIS)

    Martin, M.

    2016-01-01

    Over the past few years, numerous Accreditation Bodies, Regulatory Agencies, and State Regulations have implemented requirements for Radiation Safety Surveys following installation or modification to x-ray rooms. The objective of this session is to review best practices in performing radiation safety surveys for both Therapy and Diagnostic installations, as well as a review of appropriate survey instruments. This session will be appropriate for both therapy and imaging physicists who are looking to increase their working knowledge of radiation safety surveys. Learning Objectives: Identify Appropriate Survey Meters for Radiation Safety Surveys Develop best practices for Radiation Safety Surveys for Therapy units that include common areas of concern. Develop best practices for Radiation Safety Surveys of Diagnostic and Nuclear Medicine rooms. Identify acceptable dose levels and the factors that affect the calculations associated with performing Radiation Safety Surveys.

  2. Design of a statewide radiation survey

    International Nuclear Information System (INIS)

    Nagda, N.L.; Koontz, M.D.; Rector, H.E.; Nifong, G.D.

    1989-01-01

    The Florida Institute of Phosphate Research (FIPR) recently sponsored a statewide survey to identify all significant land areas in Florida where the state's environmental radiation rule should be applied. Under this rule, newly constructed buildings must be tested for radiation levels unless approved construction techniques are used. Two parallel surveys - a land-based survey and a population-based survey - were designed and conducted to address the objective. Each survey included measurements in more than 3000 residences throughout the state. Other information sources that existed at the outset of the study, such as geologic profiles mapped by previous investigators and terrestrial uranium levels characterized through aerial gamma radiation surveys, were also examined. Initial data analysis efforts focused on determining the extent of evidence of radon potential for each of 67 counties in the state. Within 18 countries that were determined to have definite evidence of elevated radon potential, more detailed spatial analyses were conducted to identify areas of which the rule should apply. A total of 74 quadrangles delineated by the U.S. Geological Survey, representing about 7% of those constituting the state, were identified as having elevated radon potential and being subject to the rule

  3. Verification of radioactive contamination surveys for practical use in biological research centres

    International Nuclear Information System (INIS)

    Macias, M.T.; Requejo, C.; Ruiz, M.; Pina, R.

    2006-01-01

    Unsealed sources are commonly used in science research laboratories. Their manipulation may imply a radioactive contamination hazard. Therefore, adequate and sensitive survey meters must be available, and must have an effective and accurate response to intensity and type of radiation emitted by the used radionuclides to identify and quantify the possible contamination and then be able to avoid any associated or unwanted consequences that may arise. Periodic surveys are performed to show control, any time, any place radioactive contamination is suspected, and to ensure radioisotopes are being used safely. The immediate work areas must be often checked with portable survey monitors, including the entire lab and particularly bench tops, personnel protective equipment or solely designated equipment for isotope use (micro-fuges, water baths, incubators). These are carried out with portable survey instruments like Geiger-Muller tubes, proportional counters and scintillation detectors that provide direct or indirect measurements capabilities. The Radiation Safety Office (R.S.O.) as well as the radioactive compounds working laboratories at the Instituto de Inv. Biomedicas 'A. Sols' (Madrid-Spain) are provided with an adequate radiation measurement instrument. But, before a portable survey instrument is used, several quality checks should be made (batteries, calibration sticker), and the instrument response should be tested with a check source. This paper aims at determining, with a R.S.O. procedure, these surveys working parameters -detection efficiency, calibration factors and minimum detectable activities-, using reference checking sources ( 14 C, 36 Cl, and 90 Sr/ 90 Y) with known radioactivity covering the energy range of beta emitting isotopes used in biological research. No gamma portable monitors have been tested for the R.S.O. has no gamma checking sources. Therefore, 58 beta monitors were tested, obtaining t he efficiency values, the calibration factors (Bq cm-2 s

  4. 2009 Canadian Radiation Oncology Resident Survey

    International Nuclear Information System (INIS)

    Debenham, Brock; Banerjee, Robyn; Fairchild, Alysa; Dundas, George; Trotter, Theresa; Yee, Don

    2012-01-01

    Purpose: Statistics from the Canadian post-MD education registry show that numbers of Canadian radiation oncology (RO) trainees have risen from 62 in 1999 to approximately 150 per year between 2003 and 2009, contributing to the current perceived downturn in employment opportunities for radiation oncologists in Canada. When last surveyed in 2003, Canadian RO residents identified job availability as their main concern. Our objective was to survey current Canadian RO residents on their training and career plans. Methods and Materials: Trainees from the 13 Canadian residency programs using the national matching service were sought. Potential respondents were identified through individual program directors or chief resident and were e-mailed a secure link to an online survey. Descriptive statistics were used to report responses. Results: The eligible response rate was 53% (83/156). Similar to the 2003 survey, respondents generally expressed high satisfaction with their programs and specialty. The most frequently expressed perceived weakness in their training differed from 2003, with 46.5% of current respondents feeling unprepared to enter the job market. 72% plan on pursuing a postresidency fellowship. Most respondents intend to practice in Canada. Fewer than 20% of respondents believe that there is a strong demand for radiation oncologists in Canada. Conclusions: Respondents to the current survey expressed significant satisfaction with their career choice and training program. However, differences exist compared with the 2003 survey, including the current perceived lack of demand for radiation oncologists in Canada.

  5. 2009 Canadian Radiation Oncology Resident Survey

    Energy Technology Data Exchange (ETDEWEB)

    Debenham, Brock, E-mail: debenham@ualberta.net [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada); Banerjee, Robyn [Department of Radiation Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Fairchild, Alysa; Dundas, George [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada); Trotter, Theresa [Department of Radiation Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Yee, Don [Department of Radiation Oncology, Cross Cancer Institute, University of Alberta, Edmonton, Alberta (Canada)

    2012-03-15

    Purpose: Statistics from the Canadian post-MD education registry show that numbers of Canadian radiation oncology (RO) trainees have risen from 62 in 1999 to approximately 150 per year between 2003 and 2009, contributing to the current perceived downturn in employment opportunities for radiation oncologists in Canada. When last surveyed in 2003, Canadian RO residents identified job availability as their main concern. Our objective was to survey current Canadian RO residents on their training and career plans. Methods and Materials: Trainees from the 13 Canadian residency programs using the national matching service were sought. Potential respondents were identified through individual program directors or chief resident and were e-mailed a secure link to an online survey. Descriptive statistics were used to report responses. Results: The eligible response rate was 53% (83/156). Similar to the 2003 survey, respondents generally expressed high satisfaction with their programs and specialty. The most frequently expressed perceived weakness in their training differed from 2003, with 46.5% of current respondents feeling unprepared to enter the job market. 72% plan on pursuing a postresidency fellowship. Most respondents intend to practice in Canada. Fewer than 20% of respondents believe that there is a strong demand for radiation oncologists in Canada. Conclusions: Respondents to the current survey expressed significant satisfaction with their career choice and training program. However, differences exist compared with the 2003 survey, including the current perceived lack of demand for radiation oncologists in Canada.

  6. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  7. Faculty of Radiation Oncology 2010 workforce survey.

    Science.gov (United States)

    Leung, John; Vukolova, Natalia

    2011-12-01

    This paper outlines the key results of the Faculty of Radiation Oncology 2010 workforce survey and compares these results with earlier data. The workforce survey was conducted in mid-2010 using a custom-designed 17-question survey. The overall response rate was 76%. The majority of radiation oncologist respondents were male (n = 212, 71%), but the majority of trainee respondents were female (n = 59, 52.7%). The age range of fellows was 32-92 years (median: 47 years; mean: 49 years) and that of trainees was 27-44 years (median: 31 years; mean: 31.7 years). Most radiation oncologists worked at more than one practice (average: two practices). The majority of radiation oncologists worked in the public sector (n = 169, 64.5%), with some working in 'combination' of public and private sectors (n = 65, 24.8%) and a minority working in the private sector only (n = 28, 10.7%). The hours worked per week ranged from 1 to 85 (mean: 44 h; median: 45 h) for radiation oncologists, while for trainees the range was 16-90 (mean: 47 h; median: 45 h). The number of new cases seen in a year ranged from 1 to 1100 (mean: 275; median: 250). Most radiation oncologists considered themselves generalists with a preferred sub-specialty (43.3%) or specialists (41.9%), while a minority considered themselves as generalists (14.8%). There are a relatively large and increasing number of radiation oncologists and trainees compared with previous years. The excessive workloads evident in previous surveys appear to have diminished. However, further work is required on assessing the impact of ongoing feminisation and sub-specialisation. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  8. Portable radiography using linear accelerators

    International Nuclear Information System (INIS)

    Reid, D.W.

    1984-01-01

    There are numerous instances where the availability of a portable high-energy radiography machine that could be transported to the inspection site with relative ease would save time, money, and make radiography of permanent installations, such as bridges, possible. One such machine, the Minac built by Schoenberg Radiation Inc., is commercially available. It operates at 9.3 GHz, has an electron energy on target of 3.5 MeV, and an output dose rate of 100 R/min. A second portable accelerator, recently completed at the Los Alamos National Laboratory, operates at 2.998 GHz, has electron energies on target of 6, 8, and 10 MeV, and an output dose rate of 800 R/min at 8 MeV. This paper discusses the need for and applications of portable accelerators for radiography. Physical characteristics and beam parameters of both machines are examined in detail. Problems of operating at higher frequencies to further minimize size and weight are discussed

  9. Automated 3-D Radiation Mapping

    International Nuclear Information System (INIS)

    Tarpinian, J. E.

    1991-01-01

    This work describes an automated radiation detection and imaging system which combines several state-of-the-art technologies to produce a portable but very powerful visualization tool for planning work in radiation environments. The system combines a radiation detection system, a computerized radiation imaging program, and computerized 3-D modeling to automatically locate and measurements are automatically collected and imaging techniques are used to produce colored, 'isodose' images of the measured radiation fields. The isodose lines from the images are then superimposed over the 3-D model of the area. The final display shows the various components in a room and their associated radiation fields. The use of an automated radiation detection system increases the quality of radiation survey obtained measurements. The additional use of a three-dimensional display allows easier visualization of the area and associated radiological conditions than two-dimensional sketches

  10. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  11. Development of aerial gamma radiation survey system, 1

    International Nuclear Information System (INIS)

    Tsutsumi, Masahiro; Saito, Komei; Sakamoto, Ryuichi; Nagaoka, Toshi; Moriuchi, Shigeru

    1986-05-01

    JAERI has started to develop an aerial gamma radiation survey system by a helicopter in 1980. The development of measuring instruments, the experiments in the field of natural and artificial radiation sources, and the imaginary emergency survey at a real site, were executed. This report describes mainly about the hardware and software of this system. The system consists of gamma-ray measuring instruments with NaI(Tl) scintillation detectors, microwave positioning instruments, and a data processing system for postflight data. A foreign-made geological survey system is improved on for radiation measurements. For covering the wide radiation range, detectors of various shapes and sizes are prepared, from a large volume detector, DET-1024 - four 4'' x 4'' x 16'' crystals assembly - to a 2'' diameter x 2'' NaI(Tl) crystal. Radiation and position data are recorded on a magnetic tape, and computer-processed afterwards. Moreover, scene below flight courses and internal communication are recorded on video tape with the information of clock and position superimposed. In consequence of field experiments carried out five times, basic radiation data for evaluating airborne acquired data are accumulated, and flight survey procedures are established. As more practical use, a system has been produced more compactly and functionally. Exposure rates (> 1 mR/h), energy distribution spectra, and energy window counts are obtained for radiation data. Using the Spectrum-Dose Conversion Method, the accurate exposure rates are directly calculated from pulse height spectra. Numerical tables of G(E) function converting pulse height spectra into exposures are shown in this report. As regards the analysis of survey data, process codes have been completed with either large-computer or mini-computer. (author)

  12. Method of calibration for portable detectors of ionizing radiation

    International Nuclear Information System (INIS)

    Leal, Carlos; Carrizales, Lila; Guacaran, Douglas; Moreno, Ailed; Duran, Jose

    2008-01-01

    Full text: The LSCD is beginning a process of accreditation by the national authority of Venezuela (CENCAMER), so we felt the need to modify existing protocols calibration, suggested by the IAEA (Technical Reports Series No 133) to be adjusted in accordance with international standards of ISO 17025 EA-4/02 and Mexican standard NOM-021-NUCL-2002, adapting the calibration procedure of portable radiation detectors to those standards. The procedure used in the LSCD, conducts an intercomparison between measures between the standard reference and to calibrate the instrument, thus verifying the correct operation of the equipment and its usefulness to the individual or environmental radiation monitoring, not to exceed the limits primary for the public and occupationally Staff Exposed (POE), and propose a simple way to perform this calibration procedure and comply with the standard international and national standards, ensuring the proper functioning of the instruments calibrated. One of the calculations that has proven to be a useful tool in the verification of the conditions of operating the same, it is uncertainty, this procedure allows to characterize the response of individual detector, depending on the constraints specified by the manufacturer, to optimize the calibration is necessary to consider the multiple factors that can affect the measure and evaluate the response of the same, so it is vitally important estimating the typical uncertainty associated with the calibration technique employed, but this calculation is not trivial, depends on the type of detector found usually between 5% to 20%, both in uncertainty as the linearity, which are the parameters that are set to consider an instrument in good or bad condition. Typical are calibrated are: monitors air Geiger-Muller, Ionization cameras, detector of Neutron's, Proportional Counter, Personal dosimeters. (author)

  13. Market survey of fuel cells in Mexico: Niche for low power portable systems

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez-Salgado, Joel [Programa de Ingenieria Molecular, Instituto Mexicano del Petroleo, Eje Lazaro Cardenas No 152, 07730 D. F. (Mexico); Dominguez-Aguilar, Marco A. [Laboratorio de Sintesis Quimica y Electroquimica, Instituto Mexicano del Petroleo, Eje Lazaro Cardenas No 152, 07730 D. F. (Mexico)

    2009-01-15

    This work provides an overview of the potential market in Mexico for portable electronic devices to be potentially powered by direct methanol fuel cells. An extrapolation method based on data published in Mexico and abroad served to complete this market survey. A review of electronics consumption set the basis for the future forecast and technology assimilation. The potential market for fuel cells for mobile phones in Mexico will be around 5.5 billion USD by 2013, considering a cost of 41 USD per cell in a market of 135 million mobile phones. Likewise, the market for notebook computers, PDAs and other electronic devices will likely grow in the future, with a combined consumption of fuel cell technology equivalent to 1.6 billion USD by 2014. (author)

  14. Market survey of fuel cells in Mexico: Niche for low power portable systems

    Science.gov (United States)

    Ramírez-Salgado, Joel; Domínguez-Aguilar, Marco A.

    This work provides an overview of the potential market in Mexico for portable electronic devices to be potentially powered by direct methanol fuel cells. An extrapolation method based on data published in Mexico and abroad served to complete this market survey. A review of electronics consumption set the basis for the future forecast and technology assimilation. The potential market for fuel cells for mobile phones in Mexico will be around 5.5 billion USD by 2013, considering a cost of 41 USD per cell in a market of 135 million mobile phones. Likewise, the market for notebook computers, PDAs and other electronic devices will likely grow in the future, with a combined consumption of fuel cell technology equivalent to 1.6 billion USD by 2014.

  15. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  16. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  17. Practical methods for radiation survey in nuclear installations

    International Nuclear Information System (INIS)

    Shweikani, R.

    2001-12-01

    This study is placed to those who are responsible to perform radiation survey in the nuclear installations, especially the beginners. Therefore, it gives a comprehensive view to all-important aspects related to their work starting from the structure of atoms to the practical steps for radiation survey works. So, it clarify how to perform personal monitoring, methods for monitoring surface contamination, methods for measuring radioactivity of gases and radioactive aerosols in air, monitoring radiation doses, measuring radiation influences in workplaces and finally measuring internal exposure of radiation workers in nuclear installations. Finally, The study shows some cases of breaches of radiation protection rules in some American nuclear installations and describes the final results of these breaches. The aim of this is to assure that any breach or ignore to radiation protection principles may produce bad results, and there is no leniency in implementing environmental radiation protection principles. (author)

  18. Methodical recommendations for power unit comprehensive engineering and radiation survey

    International Nuclear Information System (INIS)

    Nosovskij, A.V.

    2000-01-01

    The article describes power unit radiation survey methods developed and applied during conduction of Ch NPP unit I Comprehensive Engineering Radiation Survey. Special requirements for units under decommissioning, main survey principals, criteria for definition of volume and the order of survey for various systems of a NPP Unit are included

  19. Autonomous portable solar ultraviolet spectroradiometer (APSUS) - a new CCD spectrometer system for localized, real-time solar ultraviolet (280-400 nm) radiation measurement.

    Science.gov (United States)

    Hooke, Rebecca; Pearson, Andy; O'Hagan, John

    2014-01-01

    Terrestrial solar ultraviolet (UV) radiation has significant implications for human health and increasing levels are a key concern regarding the impact of climate change. Monitoring solar UV radiation at the earth's surface is therefore of increasing importance. A new prototype portable CCD (charge-coupled device) spectrometer-based system has been developed that monitors UV radiation (280-400 nm) levels at the earth's surface. It has the ability to deliver this information to the public in real time. Since the instrument can operate autonomously, it is called the Autonomous Portable Solar Ultraviolet Spectroradiometer (APSUS). This instrument incorporates an Ocean Optics QE65000 spectrometer which is contained within a robust environmental housing. The APSUS system can gather reliable solar UV spectral data from approximately April to October inclusive (depending on ambient temperature) in the UK. In this study the new APSUS unit and APSUS system are presented. Example solar UV spectra and diurnal UV Index values as measured by the APSUS system in London and Weymouth in the UK in summer 2012 are shown. © 2014 Crown copyright. Photochemistry and Photobiology © 2014 The American Society of Photobiology. This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland and Public Health England.

  20. American Society for Radiation Oncology (ASTRO) Survey of Radiation Biology Educators in U.S. and Canadian Radiation Oncology Residency Programs

    International Nuclear Information System (INIS)

    Rosenstein, Barry S.; Held, Kathryn D.; Rockwell, Sara; Williams, Jacqueline P.; Zeman, Elaine M.

    2009-01-01

    Purpose: To obtain, in a survey-based study, detailed information on the faculty currently responsible for teaching radiation biology courses to radiation oncology residents in the United States and Canada. Methods and Materials: In March-December 2007 a survey questionnaire was sent to faculty having primary responsibility for teaching radiation biology to residents in 93 radiation oncology residency programs in the United States and Canada. Results: The responses to this survey document the aging of the faculty who have primary responsibility for teaching radiation biology to radiation oncology residents. The survey found a dramatic decline with time in the percentage of educators whose graduate training was in radiation biology. A significant number of the educators responsible for teaching radiation biology were not fully acquainted with the radiation sciences, either through training or practical application. In addition, many were unfamiliar with some of the organizations setting policies and requirements for resident education. Freely available tools, such as the American Society for Radiation Oncology (ASTRO) Radiation and Cancer Biology Practice Examination and Study Guides, were widely used by residents and educators. Consolidation of resident courses or use of a national radiation biology review course was viewed as unlikely by most programs. Conclusions: A high priority should be given to the development of comprehensive teaching tools to assist those individuals who have responsibility for teaching radiation biology courses but who do not have an extensive background in critical areas of radiobiology related to radiation oncology. These findings also suggest a need for new graduate programs in radiobiology.

  1. Natural Sources of Radiation Exposure and the Teaching of Radioecology

    Science.gov (United States)

    Anjos, R. M.; Veiga, R.; Carvalho, C.; Sanches, N.; Estellita, L.; Zanuto, P.; Queiroz, E.; Macario, K.

    2008-01-01

    We have developed an experimental activity that introduces concepts of the natural ionizing radiation and its interaction with our contemporary environment that can be used with students from secondary to college level. The experiment is based on the use of traditional and cheap portable Geiger-Muller detectors as survey meters for "in situ"…

  2. Natural sources of radiation exposure and the teaching of radioecology

    International Nuclear Information System (INIS)

    Anjos, R M; Veiga, R; Carvalho, C; Sanches, N; Estellita, L; Macario, K; Zanuto, P; Queiroz, E

    2008-01-01

    We have developed an experimental activity that introduces concepts of the natural ionizing radiation and its interaction with our contemporary environment that can be used with students from secondary to college level. The experiment is based on the use of traditional and cheap portable Geiger–Müller detectors as survey meters for in situ measurements

  3. IN-VIVO RADIATION DOSIMETRY USING PORTABLE L BAND EPR: ON-SITE MEASUREMENT OF VOLUNTEERS IN FUKUSHIMA PREFECTURE, JAPAN

    Science.gov (United States)

    Miyake, Minoru; Nakai, Yasuhiro; Yamaguchi, Ichiro; Hirata, Hiroshi; Kunugita, Naoki; Williams, Benjamin B.; Swartz, Harold M.

    2016-01-01

    The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima. PMID:27522046

  4. In-vivo radiation dosimetry using portable L band EPR: on-site measurement of volunteers in Fukushima Prefecture, Japan

    International Nuclear Information System (INIS)

    Miyake, Minoru; Nakai, Yasuhiro; Yamaguchi, Ichiro; Kunugita, Naoki; Hirata, Hiroshi; Williams, Benjamin B.; Swartz, Harold M.

    2016-01-01

    The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima. (authors)

  5. Research progress in airborne surveys of terrestrial gamma radiation

    International Nuclear Information System (INIS)

    Burson, Z.G.

    1974-01-01

    Progress during the last few years in airborne surveys of terrestrial gamma radiation, i.e. in the measuring, recording, and interpreting of gamma ray signals in NaI(Tl) crystals, is discussed. Non-terrestrial background contributions have been accurately characterized. The feasibility of determining the water equivalent of snow cover by aerial survey techniques has been demonstrated. Repeat surveys over areas surrounding reactor sites can now be used to detect average differences of less than 1.0 μR/hr in terrestrial gamma radiation levels. New data acquisition and recording systems allow isotope concentrations and total inventories to be measured in spatial resolutions of a few hundred feet. Aerial survey data have been combined with population distribution data to obtain population exposure values from natural terrestrial gamma radiation around reactor sites

  6. Beta aerosols beacon, a truly portable continuous air monitor

    International Nuclear Information System (INIS)

    Prince, R.P.; Garber, F.W.

    1987-01-01

    The Beta Aerosols Beacon (BAB) is a portable (57 lbs) continuous air monitor designed to detect airborne radiation. Utilizing solid state detectors has eliminated the use of lead shielding usually necessary for achieving accurate readings in high background areas, making the monitor lightweight as well as portable. The size of a small suitcase, it can be carried into confined work areas, eliminating the requirement for workers to wear respirators for many maintenance tasks. This paper describes the operation and applications of the BAB

  7. An automated locating and data logging system for geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1990-01-01

    Oak Ridge National Laboratory has developed an Ultrasonic Ranging and Data System (USRADS) and interfaced the system with a Geonics EM31 terrain conductivity meter. USRADS keeps track of a surveyor's position by measuring the time-of-flight of ultrasonic pulses from an transducer carried by the surveyor in a backpack to stationary receivers arrayed over the survey area. Also built into the backpack is a radio transmitter that sends the EM31 data to a base station (van or truck) where the surveyor's position and the EM31 quadrature and inphase data are automatically recorded once a second on a portable computer. We surveyed a 13-acre landfill at Idaho National Engineering Laboratory with three people, in three days, collecting over 25,000 EM31 quadrature and inphase readings. At a normal walking pace the average distance between measurement points along the surveyor's path was about 2 ft, with an overall positioning precision of about 0.5 ft for each point. USRADS offers several advantages over conventional EM31 surveys: (1) time and money are saved because it does not require a civil survey to lay a grid before the geophysical survey begins, (2) data are directly recorded by a portable computer and are available for analysis in the field, and (3) refining or expanding the grid about an anomaly does not require civil surveying to add extra grid points. USRADS can also be used with a gamma scintillometer for radiation surveys. Currently, we are working to interface USRADS with a portable X-ray fluorescence spectrometer for detecting heavy metals in soil

  8. Fully portable blood irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1980-01-01

    A fully portable blood irradiator was developed using the beta emitter thulium-170 as the radiation source and vitreous carbon as the body of the irradiator, matrix for isotope encapsulation, and blood interface material. These units were placed in exteriorized arteriovenous shunts in goats, sheep, and dogs and the effects on circulating lymphocytes and on skin allograft retention times measured. The present work extends these studies by establishing baseline data for skin graft rejection times in untreated animals

  9. The use of portable shields in industrial radiography

    International Nuclear Information System (INIS)

    Oliveira e Silva, J.A. de.

    1988-01-01

    This paper shows techniques actually used to reduce radiations exposure taxes during examinations execution by gamma radiography in regions of high population density. A portable equipment of radiation shield for using in exams by gamma radiography in pipelines, that is an adjustable device in an object body that will be examined, joining a measured collimator and a shield geometrically arranged so that the radiation restrict to impress the radiographic film used in examination without reaching people, objects or self-movings injurious that are nearness. (C.M.) [pt

  10. Calibration procedures of area monitors in terms of the Ambient Dose Equivalent H*(10), for gamma, x-ray radiation fields

    International Nuclear Information System (INIS)

    Dieguez Davila, L.E.

    1998-01-01

    In the present thesis procedures for calibrating portable survey meters in terms of the new ICRU quantities H*(10) ambient dose equivalent are discussed. Also the remendations of International Comission on Radiation Protection in their report ICRP 60 that inludes the operational magnitudes that the International Comission of Radiation Units proposed for calibrating area monitors

  11. Surface radiation survey and soil sampling of the 300-FF-1 operable unit, Hanford Site, southeastern Washington: A case study

    International Nuclear Information System (INIS)

    Teel, S.S.; Olsen, K.B.

    1990-10-01

    The methods used for conducting a radiological characterization of the soil surface for the Phase I Remedial Investigation of a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) site is presented via a case study. The study site is an operable unit (300-FF-1) located in and adjacent to the 300 Area of the US Department of Energy's Hanford Site in southeastern Washington State. The operable unit contains liquid and solid waste disposal facilities associated with nuclear fuels fabrication. Continuous surface radiation surveying and soil sampling of selected locations were conducted. Contamination was found in several locations within the operable unit including areas near the liquid and solid waste disposal facilities. Instruments used during surveying included portable beta/gamma (P-11) detectors, and the Ultrasonic Ranging and Data System using an NaI (Tl) detector. Laboratory analyses results indicate that above-background radiation levels were primarily due to the presence of uranium. Both types of field instruments used in the study were effective in detecting surface contamination from radionuclides; however, each had specific advantages. Guidelines are presented for the optimum use of these instruments when performing a radiological characterization of the soil surface. 4 refs., 3 figs., 3 tabs

  12. Radiation survey of aircraft and heavy machinery scrap.

    Science.gov (United States)

    Idriss, Hajo; Salih, Isam; Gumaa, Elsadig; Yassin, Abbas; Yousif, E H; Abdel Hamid, Saad Eldeen M; Sam, A K

    2012-12-01

    This study was conducted primarily to survey aircraft and heavy machinery at 30 locations within Khartoum State using handheld radiation survey meters to detect and identify any radiation sources that might be present and to estimate radiation dose levels. The survey has resulted in detection of 16 sealed sources of (90)Sr and one of (226)Ra in aircraft scrap. Of course, (90)Sr sources are used in military aircraft as temperature sensors while (226)Ra is used for indicating fuel levels. These sources were found intact without spreading radioactivity contamination; however, none was detected in heavy machine scrap. The levels of radiation dose measured at 0.1m from the source fall within the range of 25.1-40.2 μSv/h with an average value of 33.52 ± 4.06 μSv/h. These orphan sources have been separated from the scrap, tested for possible leakage, conditioned and stored in waste management facility. The result of this study has revealed without doubt that the scrap constitute a serious source of public exposure and highlights the importance of legislation making radiation monitoring of scrap in the country mandatory before it is sold to metal industry for reprocessing. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. 2003 survey of Canadian radiation oncology residents

    International Nuclear Information System (INIS)

    Yee, Don; Fairchild, Alysa; Keyes, Mira; Butler, Jim; Dundas, George

    2005-01-01

    Purpose: Radiation oncology's popularity as a career in Canada has surged in the past 5 years. Consequently, resident numbers in Canadian radiation oncology residencies are at all-time highs. This study aimed to survey Canadian radiation oncology residents about their opinions of their specialty and training experiences. Methods and Materials: Residents of Canadian radiation oncology residencies that enroll trainees through the Canadian Resident Matching Service were identified from a national database. Residents were mailed an anonymous survey. Results: Eight of 101 (7.9%) potential respondents were foreign funded. Fifty-two of 101 (51.5%) residents responded. A strong record of graduating its residents was the most important factor residents considered when choosing programs. Satisfaction with their program was expressed by 92.3% of respondents, and 94.3% expressed satisfaction with their specialty. Respondents planning to practice in Canada totaled 80.8%, and 76.9% plan to have academic careers. Respondents identified job availability and receiving adequate teaching from preceptors during residency as their most important concerns. Conclusions: Though most respondents are satisfied with their programs and specialty, job availability and adequate teaching are concerns. In the future, limited time and resources and the continued popularity of radiation oncology as a career will magnify the challenge of training competent radiation oncologists in Canada

  14. Environmental dose measurement with microprocessor based portable TLD reader

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.

    1996-01-01

    Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

  15. Organization of radiation survey

    International Nuclear Information System (INIS)

    Yatsenko, V.N.; Mazanov, V.L.

    1995-01-01

    The main organizing principles which guarantee efficient activities of medical-sanitary teams of disaster medicine in emergency situations connected with radiation injuries are studied in this paper. The study has demonstrated the priority measures being carried out by radiological team of the Russian Center on Disaster Medicine Zashchita during the current and preparatory periods and in the course of emergency situation, as well as the equipping of the teams. When arranging radiation survey the main emphasis should be placed on the detection of the injured, ascertaining the place and time of location of the personnel and population starting from the moment of the accident, as well as to determine the dynamics of the power of photon radiation in this place in the same period. Special attention is paid to the necessity of coordination on interaction of radiological team of the Russian Center of Disaster Medicine Zashchita with other similar departmental services. 5 refs

  16. Establishment of a procedure to calculate the measurement uncertainties in radiation survey meters calibration

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Potiens, M.P.A.

    2000-01-01

    The Calibration Laboratory of Sao Paulo calibrates more than one thousand gamma ray survey meters a year; beside other kinds of radiotherapy, radiodiagnostic and radiation protection instruments. It has a standard (600 cm 3 ) cylinder ionization chamber (Nuclear Enterprises Ltd. model 2511/3) traceable to the Brazilian Secondary Standard Dosimetry Laboratory (SSDL) whose instruments are traceable to the BIPM. Annually the beam dosimetry is performed using this chamber and the results are used as the true values for calibration purposes. The uncertainties present in every direct or indirect measurement during the calibration procedure must be evaluated for purposes of laboratory quality control. All calculation steps in the propagation of errors are presented in this work staging from the ionization chamber charge measured with the standard instrument. Such a propagation was made in space and time, considering even the environmental quantities uncertainties. The propagation was necessary in space, because the ionization chamber measurements were performed at only one space position. The time propagation was essential due to the fact that the activity is a peculiar physical quantity which changes with time according to precise relations for a specific radionuclide. The clear indication of every measurement uncertainty is always important to quantify the quality of this measurement. Nowadays the achievement of calibration laboratory quality systems requires the expression of all uncertainties and the procedure used to evaluate it. An example of this procedure in the case of the calibration of a typical portable radiation survey meter is presented. The direct exposure rate instrument measurement was compared with the true value given by the standard instrument properly propagated and all quantities used have their uncertainties shown. (author)

  17. Survey of Radiation Protection Education and Training in Finland in 2003

    International Nuclear Information System (INIS)

    Havukainen, R.; Korpela, H.; Vaisala, S.; Piri, A.; Kettunen, E.

    2004-01-01

    The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection knowledge and needs for additional training. The questionnaire was sent to 880 radiation users and 170 radiation safety officers, 70 per cent of whom responded. The survey covered all professional groups and fields of the use of ionizing radiation except nuclear energy. The amount of radiation protection training in basic and further (specialization) training in the same vocational or academic degree varied remarkably by educational organization. The average amounts of radiation protection included in most professional degrees met the requirements. 32 per cent of workers considered their radiation protection training inadequate for their duties, and 48 per cent had completed no supplementary training in radiation protection over the last five years. Nurses working in public sector hospitals and physicians working in health centres had the greatest need for radiation protection training. 78 per cent of radiation workers in industry felt that they had sufficient radiation protection training. Co-operation between educational organizations is necessary to harmonize radiation protection training. Guidance of the Ministry of Education (the competent authority for education) is needed in this

  18. Survey of Canadian hospitals radiation emergency plans

    Energy Technology Data Exchange (ETDEWEB)

    Davis, C [Social Data Research Ltd./The Flett Consulting Group, Inc., Ottawa, ON (Canada)

    1996-02-01

    This report documents the findings of a survey of Canadian hospitals conducted by Social Data Research Ltd. during the Spring and Summer, 1995. The main objective of the survey was to determine the state of readiness of Canadian hospitals in respect of radiation emergency planning. In addition, the AECB was interested in knowing the extent to which a report by the Group of Medical Advisors, `GMA-3: Guidelines on Hospital Emergency Plans for the Management of Minor Radiation Accidents`, which was sponsored and distributed in 1993, was received and was useful to hospital administrators and emergency personnel. A self-administered questionnaire was distributed to 598 acute care hospitals, and 274 responses were received. The main conclusion of this study is that, with the exception of a few large institutions, hospitals generally do not have specific action plans to handle minor radiation accidents. (author).

  19. Survey of Canadian hospitals radiation emergency plans

    International Nuclear Information System (INIS)

    Davis, C.

    1996-02-01

    This report documents the findings of a survey of Canadian hospitals conducted by Social Data Research Ltd. during the Spring and Summer, 1995. The main objective of the survey was to determine the state of readiness of Canadian hospitals in respect of radiation emergency planning. In addition, the AECB was interested in knowing the extent to which a report by the Group of Medical Advisors, 'GMA-3: Guidelines on Hospital Emergency Plans for the Management of Minor Radiation Accidents', which was sponsored and distributed in 1993, was received and was useful to hospital administrators and emergency personnel. A self-administered questionnaire was distributed to 598 acute care hospitals, and 274 responses were received. The main conclusion of this study is that, with the exception of a few large institutions, hospitals generally do not have specific action plans to handle minor radiation accidents. (author)

  20. Radiation surveys in contaminated communities

    International Nuclear Information System (INIS)

    Knight, G.B.

    1977-01-01

    Radiation surveys of uranium contamination in Uranium City and Port Hope, Canada, are described. Samples of soil, water, and crops grown in contaminated soil and air in homes were analyzed for radon content. Following decontamination, measurements were made of γ exposure rates both inside and outside of buildings

  1. Development and pilot of an international survey: 'Radiation Therapists and Psychosocial Support'.

    Science.gov (United States)

    Elsner, Kelly L; Naehrig, Diana; Halkett, Georgia K B; Dhillon, Haryana M

    2018-06-07

    Up to one third of radiation therapy patients are reported to have unmet psychosocial needs. Radiation therapists (RTs) have daily contact with patients and can provide daily psychosocial support to reduce patient anxiety, fear and loneliness. However, RTs vary in their values, skills, training, knowledge and involvement in providing psychosocial support. The aims of this study were to: (1) develop an online survey instrument to explore RT values, skills, training and knowledge regarding patient anxiety and psychosocial support, and (2) pilot the instrument with RT professionals to assess content validity, functionality and length. An online cross-sectional survey, titled 'Radiation therapists and psychosocial support' was developed. Items included patient vignettes, embedded items from RT research, and the Professional Quality of Life Scale (ProQOL5). Four radiation oncology departments volunteered to pilot the survey; each nominated four RT staff to participate. Survey data were analysed descriptively and qualitative feedback grouped and coded to determine whether the survey needed to be refined. Thirteen of sixteen RTs completed the pilot survey and feedback form. Median time to completion was 35 mins, with 54% of respondents stating this was too long. Respondents reported content, questions and response options were relevant and appropriate. Feedback was used to: refine the survey instrument, minimise responder burden and drop out and improve functionality and quality of data collection. This pilot of the 'Radiation therapists and psychosocial support' survey instrument demonstrated content validity and usability. The main survey will be circulated to a representative sample of RTs for completion. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  2. Arduino based radiation survey meter

    International Nuclear Information System (INIS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee; Muzakkir, Amir

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr −1 ). Conversion factor (CF) value for conversion of CPM to μSvhr −1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr

  3. Nuclear Enterprises portable dose rate meter type PDR 2

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a portable battery powered dose rate meter covering the dose rate range from 0.05 to 500 mrad h -1 . It is designed to measure X- and γ-radiation dose rates over the energy range from 35 keV to 3 MeV. The radiation detector is an MX 164/S GM tube provided with a compensation sheath. The report describes the instrument under the headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  4. Radiation survey of aircraft and heavy machinery scrap

    International Nuclear Information System (INIS)

    Idriss, Hajo; Salih, Isam; Gumaa, Elsadig; Yassin, Abbas; Yousif, E.H.; Abdel Hamid, Saad Eldeen M.; Sam, A.K.

    2012-01-01

    This study was conducted primarily to survey aircraft and heavy machinery at 30 locations within Khartoum State using handheld radiation survey meters to detect and identify any radiation sources that might be present and to estimate radiation dose levels. The survey has resulted in detection of 16 sealed sources of 90 Sr and one of 226 Ra in aircraft scrap. Of course, 90 Sr sources are used in military aircraft as temperature sensors while 226 Ra is used for indicating fuel levels. These sources were found intact without spreading radioactivity contamination; however, none was detected in heavy machine scrap. The levels of radiation dose measured at 0.1 m from the source fall within the range of 25.1–40.2 μSv/h with an average value of 33.52±4.06 μSv/h. These orphan sources have been separated from the scrap, tested for possible leakage, conditioned and stored in waste management facility. The result of this study has revealed without doubt that the scrap constitute a serious source of public exposure and highlights the importance of legislation making radiation monitoring of scrap in the country mandatory before it is sold to metal industry for reprocessing. - Highlights: ► Sealed radioactive sources ( 90 Sr and 226 Ra) were detected in aircraft scrap. ► No source was detected in heavy machine scrap. ► Radiation dose measured at 0.1 m from the source can be used to estimate exposure to public. ► Monitoring of scrap was found to be useful for protection (from orphan sources).

  5. Analysis of portable gamma flaw detectors concerning radiation hygiene

    International Nuclear Information System (INIS)

    Makarova, T.V.

    1982-01-01

    Design and shields of gamma flaw detectors as one of the main factors responsible for personnel dose were studied. The analysis was conducted using the results of radiation hygienic surveys of gamma flaw detection laboratories functioning constantly in Estonia. It is shown that recently the replacement of GUP apparatuses by flaw detectors of RID and ''Gamma-RID'' (types which have design and shielding advantages is observed. However personnel doses have not reduced considerably for the last 10 years. This fact is attributed to design disadvantages of the RID and ''Gamma-RID'' apparatuses the removing of which will give the decreasing of annual personnel dose by 80 %

  6. Literature survey: health effects of radiation

    International Nuclear Information System (INIS)

    Tveten, U.; Garder, K.

    This report was originally written as a chapter of a report entitled 'Air pollution effects of electric power generation, a literature survey', written jointly by the Norwegian Institute for Air Research (NILU) and the Institutt for Atomenergi (IFA). (INIS RN242406). A survey is presented of the health effects of radiation. It has not, however, been the intention of the authors to make a complete list of all the literature relevant to this subject. The NILU/IFA report was meant as a first step towards a method of comparing the health effects of electric power generation by fission, gas and oil. Consequently information relevant to quantification of the health effects on humans has been selected. It is pointed out that quantitative information on the health effects of low radiation and dose rates, as are relevant to routine releases, does not exist for humans. The convention of linear extrapolation from higher doses and dose rates is used worldwide, but it is felt by most that the estimates are conservative. As an example of the use of the current best estimates, a calculation of normal release radiation doses is performed. (Auth.)

  7. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  8. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  9. A survey of research programs in radiation protection in Canada

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    A survey of research programs in Canada concerned with radiation protection was conducted in 1991-92 by the Joint Subcommittee on Regulatory Research (JSCRR) of the Atomic Energy Control Board (AECB) Advisory Committees on Radiological Protection and on Nuclear Safety. The purpose of this survey was to determine the current state of funding for this type of research in Canada. Funding for health-related radiation research in Canada is critical to establishing and maintaining a supply of trained professionals who can provide competent advice on health-related problems in radiation protection. The present report is an analysis of the information received in this survey. This survey concludes with the recommendation that the organization and definition of subprograms for the AECB Regulatory Research and Support Program should be completed as soon as possible. In this report the JSCRR should assist AECB staff in preparing a report in which priorities for research related to radiation protection are indicated. The sources of information noted at the end of the Discussion section of this report should be considered for this purpose. (author). 15 refs., 3 tabs.

  10. A survey of research programs in radiation protection in Canada

    International Nuclear Information System (INIS)

    1995-07-01

    A survey of research programs in Canada concerned with radiation protection was conducted in 1991-92 by the Joint Subcommittee on Regulatory Research (JSCRR) of the Atomic Energy Control Board (AECB) Advisory Committees on Radiological Protection and on Nuclear Safety. The purpose of this survey was to determine the current state of funding for this type of research in Canada. Funding for health-related radiation research in Canada is critical to establishing and maintaining a supply of trained professionals who can provide competent advice on health-related problems in radiation protection. The present report is an analysis of the information received in this survey. This survey concludes with the recommendation that the organization and definition of subprograms for the AECB Regulatory Research and Support Program should be completed as soon as possible. In this report the JSCRR should assist AECB staff in preparing a report in which priorities for research related to radiation protection are indicated. The sources of information noted at the end of the Discussion section of this report should be considered for this purpose. (author). 15 refs., 3 tabs

  11. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  12. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  13. Scientific substantiation of approaches to organization and conducting radiation surveys at the rehabilitated radiation sites

    Directory of Open Access Journals (Sweden)

    I. K. Romanovich

    2017-01-01

    Full Text Available The article is concerned with the scientific justification of approaches to the organization of the final radiation survey of facilities having radioactive contamination, after their rehabilitation. Scientific publications on the previous experience in rehabilitation of facilities contaminated with radionuclides, the organization and conducting a radiation survey before the start of the decontamination, during its implementation and after its completion were analyzed. The experience in the rehabilitation of the site for the temporary storage of spent fuel and radioactive waste in Andreeva Bay in the North-West region of Russia, the locations of peaceful nuclear explosions, experimental nuclear power plants, a radiochemical laboratory, and metallurgical plants, that do not belong to radiation facilities, has been studied. It has been established that, besides the surface contamination of the soil, areas of radioactive contamination on sites of decommissioned radiation facilities with significant depth up to 15 m along the profile are available. These local zones with depth soil contamination are persistent contaminants of the groundwater. The experience in the radiation survey of the peaceful nuclear explosions sites shows the removal of radionuclides from cavities, formed with the use of nuclear explosive technologies for peaceful purposes, on the earth’s surface. An optimized list of radionuclides to be monitored during the radiological survey of rehabilitated facilities was proposed based on the analysis of the composition of radionuclides detected at radiation sites subjected to decontamination. The optimized list includes 14 radionuclides with the half-lives of more than three years. 

  14. Portable energy: autonomy and integration in the human environment; Energie portable: autonomie et integration dans l'environnement humain

    Energy Technology Data Exchange (ETDEWEB)

    Multon, F; Delamarche, P [Rennes-2 Universite, Lab. de Physiologie et de Biomecanique de l& #x27; Exercice Mulsculaire, UMR. APS, 35 (France); Lucchese, P [CEA Fontenay-aux-Roses, Dir. de la Recherche Technologique, Hydrogene et Pile a Combustible, 92 (France); and others

    2002-07-01

    This colloquium was motivated by the possibility to recover in our environment the energy produced by our movements, but also the heat emitted and the radiations received by the human body in order to supply the energy needs of portable electronic devices (telephones, micro-computers, watches, prostheses etc..). It tries to answer the different problems raised by the implementation of portable energy sources: the energy resources in the human environment, the physical and technological processes of energy production and storage, the electronic energy conversion and remote transmission means, the intelligent energy management, and the existing and potential applications of these processes. This document brings together 16 communications presented by searchers from various domains (biology, medicine, electrochemistry, computer science, mechanics, thermodynamics, electronics etc..) on the following topics: energy in the human body, possibilities of miniaturization of fuel cells, thermo-mechanical micro-generators, thermoelectric generation, solar cells and autonomy, micro-chargeable batteries, double-layer super-capacitors (principles and electrical behaviour), renewable energies in watches, electro-mechanical devices for the exploitation of human movements energy, trans-dermal power supply, new mechanical-aided systems for blood circulation, problems and their solutions related to portable telephones, low voltage and high efficiency power electronic systems for portable applications, remote energy transmission, intelligent energy management (equipments and softwares), electromagnetic environments and health. (J.S.)

  15. Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems

    Science.gov (United States)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2004-01-01

    An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.

  16. Pediatric radiation therapy. A Japanese nationwide survey

    International Nuclear Information System (INIS)

    Nemoto, Kenji; Nagata, Yasushi; Hirokawa, Yutaka

    2006-01-01

    A national survey on the current status of pediatric radiation therapy was performed in October 2004. We sent questionnaires to 638 radiotherapy facilities in Japan (except for Kansai area) and 245 responses were analyzed. According to the database of committee of Japanese Society of Therapeutic Radiology and Oncology (JASTRO), the number of pediatric patients who received radiation therapy during 2003 in Japan was 1,101. The most frequent pediatric malignancy was brain tumor, followed by leukemia and lymphoma. The total effort of radiation therapy for children was two to six times larger than that for adult patients. An additional fee seems to be necessary for the highly technical and laborious radiation therapy required for children. (author)

  17. Portable computers - portable operating systems

    International Nuclear Information System (INIS)

    Wiegandt, D.

    1985-01-01

    Hardware development has made rapid progress over the past decade. Computers used to have attributes like ''general purpose'' or ''universal'', nowadays they are labelled ''personal'' and ''portable''. Recently, a major manufacturing company started marketing a portable version of their personal computer. But even for these small computers the old truth still holds that the biggest disadvantage of a computer is that it must be programmed, hardware by itself does not make a computer. (orig.)

  18. Insolation measurements with a portable CuS-CdS radiometer

    Science.gov (United States)

    Windawi, H. M.

    1976-01-01

    Solar radiation measurements were carried out with a portable Cu2S-Cds radiometer. The measurements were found to be accurate to better than 5% (better than 3% when sophisticated metering is employed). Calibration to an Eppley precision pyranometer is discussed.

  19. Risk management of radiation therapy. Survey by north Japan radiation therapy oncology group

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Abe, Yoshinao; Yamada, Shogo; Hareyama, Masato; Nakamura, Ryuji; Sugita, Tadashi; Miyano, Takashi

    2004-01-01

    A North Japan Radiation Oncology Group (NJRTOG) survey was carried out to disclose the risk management of radiation therapy. During April 2002, we sent questionnaires to radiation therapy facilities in northern Japan. There were 31 replies from 27 facilities. Many incidents and accidents were reported, including old cases. Although 60% of facilities had a risk management manual and/or risk manager, only 20% had risk management manuals for radiation therapy. Eighty five percent of radiation oncologists thought that incidents may be due to a lack of manpower. Ninety percent of radiation oncologists want to know the type of cases happened in other facilities. The risk management system is still insufficient for radiation therapy. We hope that our data will be a great help to develop risk management strategies for radiation therapy for all radiation oncologists in Japan. (author)

  20. Portable ratemeter - 95/0742-1/6 user guide

    International Nuclear Information System (INIS)

    Campbell, J.T.

    1982-01-01

    This portable hand held instrument powered by two 9 volt batteries is designed to be used with solid state α, β or γ radiation detectors and gives a visible and audible indication of counting rates. The instrument is housed in a plastic case and can be stored in a purpose-built carrying case. (U.K.)

  1. Public reaction to the natural radiation survey

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L [National Radiological Protection Board, Harwell (UK)

    1983-11-01

    A natural radiation survey of a cross-section of homes in the UK has been under way for over a year. Members of the public are contacted by post by the NRPB and asked whether they would be willing to have dosemeters in their homes for 12 months. To date the survey has elicited approximately 50% positive response for over a year which is encouragingly high compared to response rates of postal surveys in general. The survey has attracted notable media attention; in the main the tenor of the stories has been accurate and informative and only a handful could be described as sensational.

  2. EMERGENCY RADIATION SURVEY DEVICE ONBOARD THE UAV

    Directory of Open Access Journals (Sweden)

    S. Bogatov

    2013-08-01

    Full Text Available Radiation survey device (RSD on the base of unmanned aerial vehicle (UAV was developed as an equipment of rescue forces for radiation situation reconnaissance in case of emergency. RSD is multi range radiometer with spectrometer functions capable to work within gamma ray fields of dose rate 10–7 – 10–1 Sievert per hour. UAV md4-1000 (Microdrones GmbH, Germany was selected as the RSD carrier as a reliable vehicle with appropriate properties. Short description of RSD, UAV and developed software features as well as sensitivity assessments for different radiation sources are presented.

  3. Particle Laden Turbulence in a Radiation Environment Using a Portable High Preformace Solver Based on the Legion Runtime System

    Science.gov (United States)

    Torres, Hilario; Iaccarino, Gianluca

    2017-11-01

    Soleil-X is a multi-physics solver being developed at Stanford University as a part of the Predictive Science Academic Alliance Program II. Our goal is to conduct high fidelity simulations of particle laden turbulent flows in a radiation environment for solar energy receiver applications as well as to demonstrate our readiness to effectively utilize next generation Exascale machines. The novel aspect of Soleil-X is that it is built upon the Legion runtime system to enable easy portability to different parallel distributed heterogeneous architectures while also being written entirely in high-level/high-productivity languages (Ebb and Regent). An overview of the Soleil-X software architecture will be given. Results from coupled fluid flow, Lagrangian point particle tracking, and thermal radiation simulations will be presented. Performance diagnostic tools and metrics corresponding the the same cases will also be discussed. US Department of Energy, National Nuclear Security Administration.

  4. Palliative care and palliative radiation therapy education in radiation oncology: A survey of US radiation oncology program directors.

    Science.gov (United States)

    Wei, Randy L; Colbert, Lauren E; Jones, Joshua; Racsa, Margarita; Kane, Gabrielle; Lutz, Steve; Vapiwala, Neha; Dharmarajan, Kavita V

    The purpose of this study was to assess the state of palliative and supportive care (PSC) and palliative radiation therapy (RT) educational curricula in radiation oncology residency programs in the United States. We surveyed 87 program directors of radiation oncology residency programs in the United States between September 2015 and November 2015. An electronic survey on PSC and palliative RT education during residency was sent to all program directors. The survey consisted of questions on (1) perceived relevance of PSC and palliative RT to radiation oncology training, (2) formal didactic sessions on domains of PSC and palliative RT, (3) effective teaching formats for PSC and palliative RT education, and (4) perceived barriers for integrating PSC and palliative RT into the residency curriculum. A total of 57 responses (63%) was received. Most program directors agreed or strongly agreed that PSC (93%) and palliative radiation therapy (99%) are important competencies for radiation oncology residents and fellows; however, only 67% of residency programs had formal educational activities in principles and practice of PSC. Most programs had 1 or more hours of formal didactics on management of pain (67%), management of neuropathic pain (65%), and management of nausea and vomiting (63%); however, only 35%, 33%, and 30% had dedicated lectures on initial management of fatigue, assessing role of spirituality, and discussing advance care directives, respectively. Last, 85% of programs reported having a formal curriculum on palliative RT. Programs were most likely to have education on palliative radiation to brain, bone, and spine, but less likely on visceral, or skin, metastasis. Residency program directors believe that PSC and palliative RT are important competencies for their trainees and support increasing education in these 2 educational domains. Many residency programs have structured curricula on PSC and palliative radiation education, but room for improvement exists in

  5. Attempt of portable HLS

    International Nuclear Information System (INIS)

    Matsui, S.

    1999-01-01

    This article presents the work that has been made to get a reliable magnet level surveys of the Spring-8 ring. The hydrostatic level system (HLS) completed with a capacitive sensor of water surface, has been used. If the length is about 20 m and the inner diameter of the water pipe is 10 mm, the decay time is stable within a few minutes after the sensor was set on stage. Thus the portable HLS is convenient for measuring points between the reference level ones

  6. Development of a portable radon progeny monitor

    International Nuclear Information System (INIS)

    Iimoto, Takeshi; Kosako, Toshiso; Sugiura, Nobuyuki

    2000-01-01

    Important nuclides in the radon family contributing to the effective dose are the members of the radon short-life progeny, 218 Po and 214 Po and direct measurement of these progenies is suitable for dosimetry. Survey of the radon progeny concentrations in a number of dwellings and offices is very difficult because we have no convenient instrument for the measurement. At present, radon dosimetry is carried out based on the concentration of the parent radon itself. Therefore, for accurate estimation of public or personal effective dose, it is necessary to develop a facile and portable radon progeny monitor. In this study, a portable radon progeny monitor (PRPM) was designed and developed to automatically estimate the individual progeny concentration in the natural environment. The properties of PRPM were investigated. The dimensions of the entire instrument were 65 x 145 x 170 mm and the total weight was 780 g. The portability of PRPM was much superior to the conventional instrument. The PRPM can operate automatically to estimate individual progeny concentration. All component materials of the monitor were selected based on the data of specified performance, cost performance and availability bon the market. The concentration of individual radon progeny was estimated by the build-up decay. It was concluded that PRPM is much suitable for outdoor study and personal dose estimation, as well as indoor measurement. In the field survey, especially in mines and caverns, PRPM is found as a valuable and convenient instrument. (M.N.)

  7. Safety practices, perceptions, and behaviors in radiation oncology: A national survey of radiation therapists.

    Science.gov (United States)

    Woodhouse, Kristina Demas; Hashemi, David; Betcher, Kathryn; Doucette, Abigail; Weaver, Allison; Monzon, Brian; Rosenthal, Seth A; Vapiwala, Neha

    Radiation therapy is complex and demands high vigilance and precise coordination. Radiation therapists (RTTs) directly deliver radiation and are often the first to discover an error. Yet, few studies have examined the practices of RTTs regarding patient safety. We conducted a national survey to explore the perspectives of RTTs related to quality and safety. In 2016, an electronic survey was sent to a random sample of 1500 RTTs in the United States. The survey assessed department safety, error reporting, safety knowledge, and culture. Questions were multiple choice or recorded on a Likert scale. Results were summarized using descriptive statistics and analyzed using multivariate logistic regression. A total of 702 RTTs from 49 states (47% response rate) completed the survey. Respondents represented a broad distribution across practice settings. Most RTTs rated department patient safety as excellent (61%) or very good (32%), especially if they had an incident learning system (ILS) (odds ratio, 2.0). Only 21% reported using an ILS despite 58% reporting an accessible ILS in their department. RTTs felt errors were most likely to occur with longer shifts and poor multidisciplinary communication; 40% reported that burnout and anxiety negatively affected their ability to deliver care. Workplace bullying was also reported among 17%. Overall, there was interest (62%) in improving knowledge in patient safety. Although most RTTs reported excellent safety cultures within their facilities, overall, there was limited access to and utilization of ILSs by RTTs. Workplace issues identified may also represent barriers to delivering quality care. RTTs were also interested in additional resources regarding quality and safety. These results will further enhance safety initiatives and inform future innovative educational efforts in radiation oncology. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. Health survey of radiation workers. Results of questionnaire

    International Nuclear Information System (INIS)

    Morikawa, Kaoru; Aoyama, Takashi; Kawagoe, Yasumitsu; Sunayashiki, Tadashi; Tanaka, Kiyoshi; Nishitani, Motohiro; Yoshinaga, Nobuharu

    1998-01-01

    The Japanese Society of Radiological Technology asked radiation workers about the radiation doses and the state of their health as well as family. The reports by the Health and Welfare Ministry were referenced to compare radiation workers with others. The questionnaire was sent to about 4,000 members, and returned from 2,479. The survey showed that 684 persons (27.6%) felt health anxiety, 455 persons (18.4%) had medical check for recent one year, and 1,645 persons (66.4%) had anamnesis. Radiation doses for one year and cumulated doses varied according to engaging duration. (K.H.)

  9. Survey of radiation protection programmes for transport

    International Nuclear Information System (INIS)

    Lizot, M.T.; Perrin, M.L.; Sert, G.; Lange, F.; Schwarz, G.; Feet, H.J.; Christ, R.; Shaw, K.B.; Hughes, J.S.; Gelder, R.

    2001-07-01

    The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

  10. Portable Exhauster Position Paper

    International Nuclear Information System (INIS)

    KRISKOVICH, J.R.

    1999-01-01

    This document identifies the tasks that are involved in preparing the ''standby'' portable exhauster to support Interim Stabilization's schedule for saltwell pumping. A standby portable exhaust system will be assigned to any facility scheduled to be saltwell pumped with the exception of 241-S farm, 241-SX farm or 241-T farm. The standby portable exhauster shall be prepared for use and placed in storage. The standby portable exhaust system shall be removed from storage and installed to ventilate tanks being pumped that reach 25% LFL. There are three tasks that are evaluated in this document. Each task shall be completed to support portable exhaust system installation and operation. They are: Pre Installation Task; Portable Exhaust System Storage Task; and Portable Exhaust System Installation and Operation Task

  11. [A Survey about the Radiation Effects and A Health Survey of Fukushima Inhabitants after the Fukushima Daiichi Nuclear Power Plant Accident].

    Science.gov (United States)

    Okazaki, Ryuji; Ohga, Kazuhiro; Yoko-O, Makoto; Kohzaki, Masaoki

    According to questionnaire surveys in 2011 and 2013 about the health effects of radiation after the Fukushima Daiichi Nuclear Power Plant Accident, the guardians of child patients were more anxious than doctors and medical students. Also, according to the thyroid examinations in a Fukushima health survey, 190 cases of thyroid cancer were reported, and anxiety about radiation effects remained. This study is based on a survey about the guardians of child patients anxiety about radiation effects six years after the nuclear power plant accident, and includes a questionnaire survey about radiation effects and thyroid examinations in a Fukushima health survey. Anonymous question sheets with 20 questions were sent to pediatric medical facilities in Fukushima, and the parents of children who consulted the pediatric and medical staff answered the questionnaire. Thirty percent of the guardians of child patients had never been educated about radiation and 67% had never been educated about the effects of radiation on humans. The guardians of child patients were more anxious than the medical staff about thyroid cancer, health effects on children and genetic effects. Our results indicate that the guardians of child patients think that the increase in the incidence of thyroid cancer is due to radiation effects after the nuclear power plant accident and they desire continued thyroid examinations.

  12. Development of a portable equipment for identification of radionuclides

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Carvalho, Paulo Victor R. de; Nedjah, Nadia; Mourelle, Luiza de Macedo

    2014-01-01

    The rapid and automatic identification of radionuclides present in a radioactive sample detected in the field, is information that helps in decision making. In areas of high traffic of people and materials, such as ports and airports as well as at major events, radiation monitoring, together with the identification of the radionuclide, it is advisable within protective standards to the public. The correct identification of radionuclides depends on the ability to determine whether specific peaks energy sources are present in the spectrum of gamma radiation sources. Radionuclides can be identified by these energy characteristics in the sense that the energy value associated with these peaks in the spectrum corresponds to the radiation sources present in the sample. There are many methods that can be used for automatic identification of radionuclides. Most of them are based on software algorithms for the detection of peaks in the energy spectrum. Processing time of these tasks can be very long for applications requiring quick responses, as in equipment portable. A dedicated digital hardware offers better performance for tasks with high processing demand like this. This work shows the development of a handle Portable radionuclides based on a digital hardware solution using a FPGA (Field Programmable Gate Array) for implementing a clustering algorithm for the detection of energy peaks. (author)

  13. Experimental and numerical investigations of radiation characteristics of Russian portable/compact pulsed neutron generators: ING-031, ING-07, ING-06 and ING-10-20-120

    International Nuclear Information System (INIS)

    Chernikova, D.; Romodanov, V.L.; Belevitin, A.G.; Afanas'ev, V.V.; Sakharov, V.K.; Bogolubov, E.P.; Ryzhkov, V.I.; Khasaev, T.O.; Sladkov, A.A.; Bitulev, A.A.

    2014-01-01

    The present paper discusses results of full-scale experimental and numerical investigations of influence of construction materials of portable pulsed neutron generators ING-031, ING-07, ING-06 and ING-10-20-120 (VNIIA, Russia) to their radiation characteristics formed during and after an operation (shutdown period). In particular, it is shown that an original monoenergetic isotropic angular distribution of neutrons emitted by TiT target changes into the significantly anisotropic angular distribution with a broad energy spectrum stretching to the thermal region. Along with the low-energetic neutron part, a significant amount of photons appears during the operation of generators. In the pulse mode of operation of neutron generator, a presence of the construction materials leads to the “tailing” of the original neutron pulse and the appearance of an accompanying photon pulse at ∼3ns after the instant neutron pulse. In addition to that, reactions of neutron capture and inelastic scattering lead to the creation of radioactive nuclides, such as 58 Co, 62 Cu, 64 Cu and 18 F, which form the so-called activation radiation. Thus, the selection of a portable neutron generator for a particular type of application has to be done considering radiation characteristics of the generator itself. This paper will be of interest to users of neutron generators, providing them with valuable information about limitations of a specific generator and with recommendations for improving the design and performance of the generator as a whole

  14. Human Portable Radiation Detection System Communications Package Evaluation

    International Nuclear Information System (INIS)

    Morgen, Gerald P.; Peterson, William W.

    2009-01-01

    Testing and valuation of the Human Portable Radiation Detection System Communications Package for the US Coast Guard. The main components of the HCP field kit are an Archer Field PC(reg s ign) and an Iridium satellite phone, along with various charging components and cables. The Archer Field PC has an Enfora Global System for Mobile/General Packet Radio System (GSM/GPRS) wireless cellular modem installed via the compact flash (CF) port. The Iridium satellite phone has a serial communication interface attached. The Archer Field PC is running Windows Mobile(reg s ign) 5.0 operating system. Included Microsoft products are Excel(reg s ign) Mobile, PowerPoint(reg s ign) Mobile, Word(reg s ign) Mobile, and Internet Explorer(reg s ign) Mobile. There is an Outlook(reg s ign) Email program that can be accessed via sending a file or the Messaging link. The Cambridge Computer Corporation vxHpc program is installed to provide a Hyperterm-like software product. vxHpc supports multiple communication protocols. An AT and T SIM card was provided for the GSM wireless cellular modem. A check with AT and T determined the SIM card was not activated to provide cellular service. The Iridium satellite phone did not have a SIM card and has no service. The Archer Field PC boots into a HCP program, displaying the Main Menu. The following actions can be executed by selecting the appropriate box: Spectrum Download, Spectrum Transfer, and Admin Control. The Spectrum Download function uses the serial communication port to download data files from another device, such as a Radiation Isotope Identification Device (RIID). The Spectrum Transfer function uses either the installed wireless cellular modem or the Iridium satellite phone (attached to the serial communication port) to send data files to a computer modem at the Laboratories and Scientific Services (LSS). The Admin Control function allows entering phone numbers and data file deletion. PNNL recommends that DNDO (and/or CG) contact Sanmina

  15. Benign disease in radiation therapy: a survey in Belgium

    International Nuclear Information System (INIS)

    Beauduin, M.; Deneufbourg, J.M.; Deneve, W.; Hermans, J.; Hoornaert, M.T.; Scalliet, P.; Spaas, P.; Vanderick, J.; Dijcke, V.; Van Houtte, P.; Vynckier, S.; Weltens, C.

    2001-01-01

    In 1996 and 2000, a survey of radiation practice in Belgium was performed by sending a questionnaire to the different centers asking their opinion and number of patients treated. There was a great similarity between the two surveys both for indications and total number of patients irradiated. For the most common indications (prevention of cheloids, heterotopic bone formation, hyperthyroid ophthalmopathy), there was a trend to use similar radiation technique following recent publications. In contrast, if the number of cases of macular degeneration is declining, the prevention of vessels restenosis is becoming more and more an indication. (authors)

  16. Assessment of ambient dose equivalent rate performance of an automatic survey meter as an instrument to quantify the presence of radiation in soils

    CERN Document Server

    Yoshimura, E M; Okuno, E

    2002-01-01

    Those who work in radiation protection are faced with various quantities that were created to account for the effects of ionizing radiation in the human body. As far as the experimental point of view is concerned, each available equipment is planned to measure a distinct quantity, for a specific radiation protection application, and it is not always clear which one it is. This paper shows a series of tests, planned and applied to a portable gamma ray spectrometer, in order to assure that the monitoring low dose levels of radiation with it is reliable. The equipment is fully automated and does not allow modifications of the conversion factors from counts to ambient dose equivalent. It is therefore necessary to assure that the values provided by the equipment are correct and refer to the actual situation one expects to find in practice. The system is based on an NaI(Tl) scintillation detector, mounted with its electronics in a portable case, suitable for field measurements. It measures ambient dose equivalent r...

  17. User's guide for survey-meter- and film-badge-dosimetry data bases

    International Nuclear Information System (INIS)

    Phillips, W.G.; Sherman, S.; Young, R.

    1981-05-01

    This manual describes the data storage and retrieval system designed by Environmental Monitoring Systems Laboratory Las Vegas (EMSL-LV) for radiation exposure data recorded in offsite areas during and after nuclear weapons tests conducted at the Nevada Test Site in the 1950's and early 1960's. Referred to hereinafter as the EMSL-LV system, this system contains two distinct subsets of offsite radiological measurements collected during early nuclear atmospheric tests at the Nevada Test Site. The purpose of the manual is to present the methods for using the EMSL-LV system to examine all or any portion of either data subset. The two distinct subsets which comprise the EMSL-LV system are survey meter data and film badge dosimetry data. The survey meter data consist of readings obtained from portable radiation monitoring instruments used around the Nevada Test Site during the 1950's and early 1960's to measure radiation exposure rates resulting from the nuclear testing program. The dosimetry data consist of measurements of integrated radiation exposure made with film badge type dosimeters in areas surrounding the Nevada Test Site

  18. Survey of sexual educational needs in radiation oncology patients

    International Nuclear Information System (INIS)

    Chen, L.; Sweeney, P.; Wallace, G.; Neish, P.; Vijayakumar, S.

    1997-01-01

    Purpose: To assess the knowledge of and need for education about sexuality in oncology patients treated with radiation therapy. Methods and Materials: Patients who received radiation therapy for any disease site were given a self-assessment survey to complete to determine their opinions on sexuality and needs for sexual education. The surveys were given to patients on follow-up visit seen approximately 6 months to 2 years after radiation therapy. All patients were diagnosed with a malignancy and asked to participate on a voluntary basis; confidentiality was ensured by excluding any identifying patient information on the survey form. Respondents were polled with a survey that consisted of 17 questions about their sexual activity. Questions were broadly categorized into the following: definition of sexual activity, frequency of sexual activity prior to and after diagnosis and treatment of cancer, perception of sexual attractiveness, sexual satisfaction in the relationship, patient perception of partner's sexual satisfaction in the relationship, educational needs with regard to sexuality after therapy for cancer, and demographic information. Results: All patients were over age 18, and received radiation therapy as part of the treatment. Patients with all disease sites were included in the survey, regardless of stage or diagnosis. A total of 28 patients completed the survey form, which was approved by our institutional review board. Forty-three percent of patients felt that the cancer diagnosis or treatment effect was the cause of not engaging in sexual intercourse. Fifty percent reported not having the same sexual desire as before the diagnosis of cancer, while 46% reported having the same sexual desire as prior to the diagnosis of cancer. Forty-six percent felt less attractive than before the diagnosis of cancer, while 43% felt the same as before diagnosis. Thirty-six percent of patients received no information with regards to sexuality and cancer, while 18% received

  19. Survey of Tsuruga inhabitants concerning radiation and its risks

    International Nuclear Information System (INIS)

    Shinoda, Yoshihiko; Yamano, Naoki

    2015-01-01

    The Fukushima Daiichi nuclear accident has led to changes in the acceptance of nuclear power in many people. The authors conducted an opinion survey of 300 adult inhabitants of Tsuruga city in Fukui prefecture, Japan. The aim of this survey is to obtain people's opinions concerning radiation and its risks. Authors classified Tsuruga inhabitants on the basis of responses to questions on the concept and knowledge of risk and the cognition of radiation by factor and cluster analyses of multivariable analysis. Using the results of these analyses, Tsuruga inhabitants have been assigned to five categories: “acceptance group,” “anxiety group,” and three intermediate groups. (author)

  20. In vivo quantification of lead in bone with a portable x-ray fluorescence system--methodology and feasibility.

    Science.gov (United States)

    Nie, L H; Sanchez, S; Newton, K; Grodzins, L; Cleveland, R O; Weisskopf, M G

    2011-02-07

    This study was conducted to investigate the methodology and feasibility of developing a portable x-ray fluorescence (XRF) technology to quantify lead (Pb) in bone in vivo. A portable XRF device was set up and optimal settings of voltage, current, and filter combination for bone lead quantification were selected to achieve the lowest detection limit. The minimum radiation dose delivered to the subject was calculated by Monte Carlo simulations. An ultrasound device was used to measure soft tissue thickness to account for signal attenuation, and an alternative method to obtain soft tissue thickness from the XRF spectrum was developed and shown to be equivalent to the ultrasound measurements (intraclass correlation coefficient, ICC = 0.82). We tested the correlation of in vivo bone lead concentrations between the standard KXRF technology and the portable XRF technology. There was a significant correlation between the bone lead concentrations obtained from the standard KXRF technology and those obtained from the portable XRF technology (ICC = 0.65). The detection limit for the portable XRF device was about 8.4 ppm with 2 mm soft tissue thickness. The entrance skin dose delivered to the human subject was about 13 mSv and the total body effective dose was about 1.5 µSv and should pose minimal radiation risk. In conclusion, portable XRF technology can be used for in vivo bone lead measurement with sensitivity comparable to the KXRF technology and good correlation with KXRF measurements.

  1. In vivo quantification of lead in bone with a portable x-ray fluorescence system-methodology and feasibility

    International Nuclear Information System (INIS)

    Nie, L H; Sanchez, S; Newton, K; Weisskopf, M G; Grodzins, L; Cleveland, R O

    2011-01-01

    This study was conducted to investigate the methodology and feasibility of developing a portable x-ray fluorescence (XRF) technology to quantify lead (Pb) in bone in vivo. A portable XRF device was set up and optimal settings of voltage, current, and filter combination for bone lead quantification were selected to achieve the lowest detection limit. The minimum radiation dose delivered to the subject was calculated by Monte Carlo simulations. An ultrasound device was used to measure soft tissue thickness to account for signal attenuation, and an alternative method to obtain soft tissue thickness from the XRF spectrum was developed and shown to be equivalent to the ultrasound measurements (intraclass correlation coefficient, ICC = 0.82). We tested the correlation of in vivo bone lead concentrations between the standard KXRF technology and the portable XRF technology. There was a significant correlation between the bone lead concentrations obtained from the standard KXRF technology and those obtained from the portable XRF technology (ICC = 0.65). The detection limit for the portable XRF device was about 8.4 ppm with 2 mm soft tissue thickness. The entrance skin dose delivered to the human subject was about 13 mSv and the total body effective dose was about 1.5 μSv and should pose minimal radiation risk. In conclusion, portable XRF technology can be used for in vivo bone lead measurement with sensitivity comparable to the KXRF technology and good correlation with KXRF measurements. (note)

  2. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  3. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  4. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  5. Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine

    International Nuclear Information System (INIS)

    Cho, Jeong Yeon; Han, Won Jeong; Kim, Eun Kyung

    2007-01-01

    The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines

  6. Natural terrestrial radiation exposure in Hong Kong. A survey on environmental gamma absorbed dose rate in air

    International Nuclear Information System (INIS)

    Wong, M.C.; Poon, H.T.; Chan, Y.K.; So, C.K.

    2000-01-01

    Hong Kong is a metropolitan city located on the southern coast of China with a population of some six million. About 90% of the population is concentrated in heavily built-up residential and commercial areas, which accounts for less than 50% of the total area in the territory. Hong Kong Observatory, 134A Nathan Road, Kowloon, Hong Kong, China. In order to understand the spatial variations in the environmental radiation levels in Hong Kong, the Hong Kong Observatory (HKO) in early 1999 conducted a study of the environmental gamma absorbed dose rate in air. The study combined data collected by the HKO radiation monitoring network (RMN) and data from a comprehensive territory-wide radiological survey conducted in January and February 1999. The RMN of ten stations each equipped with a Reuter-Stokes Model RSS-1013 HPIC has been in operation since 1987 to continuously monitor the environmental radiation levels over the territory as part of the emergency monitoring programme for response to nuclear accidents at a nearby nuclear power station. The terrestrial component of the environmental radiation field was estimated by subtracting from the measurements the cosmic contribution, which is determined to be about 39 nGy/h from measurements conducted over two large fresh water reservoirs. The RMN data with the long history was analysed to derive the seasonal variations in the environmental radiation levels. On average the environmental gamma absorbed dose rate in air in January and February is 1.03 times of the annual figure. This seasonal correction was applied to the results of the year 1999 survey. As the radiation field in the heavily built-up areas is enhanced by contribution from buildings, in the territory-wide survey measurements were made both in the open field and built-up areas. The territory of Hong Kong was divided into 42 grid boxes of 5 km x 5 km for open field and 61 grid boxes of 2.5 km x 2.5 km for built-up areas according to the population and land use. A

  7. A portable accelerator control toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Watson, W.A. III

    1997-06-01

    In recent years, the expense of creating good control software has led to a number of collaborative efforts among laboratories to share this cost. The EPICS collaboration is a particularly successful example of this trend. More recently another collaborative effort has addressed the need for sophisticated high level software, including model driven accelerator controls. This work builds upon the CDEV (Common DEVice) software framework, which provides a generic abstraction of a control system, and maps that abstraction onto a number of site-specific control systems including EPICS, the SLAC control system, CERN/PS and others. In principle, it is now possible to create portable accelerator control applications which have no knowledge of the underlying and site-specific control system. Applications based on CDEV now provide a growing suite of tools for accelerator operations, including general purpose displays, an on-line accelerator model, beamline steering, machine status displays incorporating both hardware and model information (such as beam positions overlaid with beta functions) and more. A survey of CDEV compatible portable applications will be presented, as well as plans for future development.

  8. A portable accelerator control toolkit

    International Nuclear Information System (INIS)

    Watson, W.A. III.

    1997-01-01

    In recent years, the expense of creating good control software has led to a number of collaborative efforts among laboratories to share this cost. The EPICS collaboration is a particularly successful example of this trend. More recently another collaborative effort has addressed the need for sophisticated high level software, including model driven accelerator controls. This work builds upon the CDEV (Common DEVice) software framework, which provides a generic abstraction of a control system, and maps that abstraction onto a number of site-specific control systems including EPICS, the SLAC control system, CERN/PS and others. In principle, it is now possible to create portable accelerator control applications which have no knowledge of the underlying and site-specific control system. Applications based on CDEV now provide a growing suite of tools for accelerator operations, including general purpose displays, an on-line accelerator model, beamline steering, machine status displays incorporating both hardware and model information (such as beam positions overlaid with beta functions) and more. A survey of CDEV compatible portable applications will be presented, as well as plans for future development

  9. Multiagency radiation survey and site investigation manual (MARSSIM): Survey design

    International Nuclear Information System (INIS)

    Abelquist, E.W.; Berger, J.D.

    1996-01-01

    This paper describes the MultiAgency Radiation Survey and Site Investigation Manual (MARSSIM) strategy for designing a final status survey. The purpose of the final status survey is to demonstrate that release criteria established by the regulatory agency have been met. Survey design begins with identification of the contaminants and determination of whether the radionuclides of concern exist in background. The decommissioned site is segregated into Class 1, Class 2, and Class 3 areas, based on contamination potential, and each area is further divided into survey units. Appropriate reference areas for indoor and outdoor background measurements are selected. Survey instrumentation and techniques are selected in order to assure that the instrumentation is capable of detecting the contamination at the derived concentration guideline level (DCGL). Survey reference systems are established and the number of survey data points is determined-with the required number of data points distributed on a triangular grid Pattern. Two suitistical tests are used to evaluate data from final status surveys. For contaminants that are b, present in background, the Wilcoxon Rank Sum test is used; for contaminants that are not present in background, the Wilcoxon Signed Rank (or Sign) test is used. The number of data points needed to satisfy these nonparametric tests is based on the contaminant DCGL value, the expected Standard deviation of the contaminant in background and in the survey unit, and the acceptable probability of making Type I and Type II decision errors. The MARSSIM also requires a reasonable level of assurance that any small areas of elevated residual radioactivity that could be significant relative to regulatory limits are not missed during the final status survey. Measurements and sampling on a specified grid size are used to obtain an adequate assurance level that small locations of elevated radioactivity will Still satisfy DCGLs-applicable to small areas

  10. Calculation of the Cardiothoracic Ratio from Portable Anteroposterior Chest Radiography

    Science.gov (United States)

    Chon, Sung Bin; Oh, Won Sup; Cho, Jun Hwi; Kim, Sam Soo

    2011-01-01

    Cardiothoracic ratio (CTR), the ratio of cardiac diameter (CD) to thoracic diameter (TD), is a useful screening method to detect cardiomegaly, but is reliable only on posteroanterior chest radiography (chest PA). We performed this cross-sectional 3-phase study to establish reliable CTR from anteroposterior chest radiography (chest AP). First, CDChest PA/CDChest AP ratios were determined at different radiation distances by manipulating chest computed tomography to simulate chest PA and AP. CDChest PA was inferred from multiplying CDChest AP by this ratio. Incorporating this CD and substituting the most recent TDChest PA, we calculated the 'corrected' CTR and compared it with the conventional one in patients who took both the chest radiographies. Finally, its validity was investigated among the critically ill patients who performed portable chest AP. CDChest PA/CDChest AP ratio was {0.00099 × (radiation distance [cm])} + 0.79 (n = 61, r = 1.00, P chest AP with an available previous chest PA. This might help physicians detect congestive cardiomegaly for patients undergoing portable chest AP. PMID:22065900

  11. Application of a radiation detector in the interdisciplinary study. 1. Portable fluorescent X-ray analysis using the Si-PIN photodiode

    International Nuclear Information System (INIS)

    Ito, Yutaka

    2000-01-01

    As a semiconductor used for X-ray detector has excellent resolution, it must be cooled by liquid nitrogen at its use, which is a limitation on its actual use and applications. Then, a compound detector with wider bandwidth such as CdTe and HgI 2 has conventionally been used to attempt to use the detector at room temperature. Here was adopted an Si-PIN photodiode for a representative small type semiconductor detector unnecessary for liquid nitrogen, to introduce small and portable fluorescent X-ray analyzer for its application. As Si-PIN can work at room temperature, it has large leak current and insufficiently spread empty phase, so it is used by cooling due to Peltier element and so on. Then, here was used an X-ray detector, XR-100CR of AMPTEK Inc. composed of Si-PIN photodiode and a Pre-AMP. And, for a portable fluorescent X-ray analyzer, the Si-PIN photodiode detector of AMPTEK Inc., and a closely sealed small radiation source of 50 μ Ci 241 Am for excitation of X-ray in specimen were used. Its working principle consists of excitation of elements in a specimen with X- and gamma-ray from 241 Am, and detection of emitted fluorescent X-ray with Si-PIN photodiode. (G.K.)

  12. Exploring microdischarges for portable sensing applications.

    Science.gov (United States)

    Gianchandani, Y B; Wright, S A; Eun, C K; Wilson, C G; Mitra, B

    2009-10-01

    This paper describes the use of microdischarges as transducing elements in sensors and detectors. Chemical and physical sensing of gases, chemical sensing of liquids, and radiation detection are described. These applications are explored from the perspective of their use in portable microsystems, with emphasis on compactness, power consumption, the ability to operate at or near atmospheric pressure (to reduce pumping challenges), and the ability to operate in an air ambient (to reduce the need for reservoirs of carrier gases). Manufacturing methods and performance results are described for selected examples.

  13. Generic assessment of radiation exposures to workers in a portable smelter and to the surrounding population

    International Nuclear Information System (INIS)

    Randolph, M.L.; Watson, A.P.; O'Donnell, F.R.

    1978-10-01

    A scenario for operation of a proposed portable smelter has been developed by National Lead Company of Ohio to recycle radioactively contaminated ferrous scrap arising from modifications at nuclear facilities of the Department of Energy. The current generic study complements that work by developing tables of radiation dose conversion factors for estimation of external whole-body doses and 50-year whole-body internal dose commitments to routine workers in the smelter and to the public within 50 miles of the smelter. Applications of the tables to specific cases require site-specific source terms consisting of amounts of radionuclides present in scrap metal, separation efficiency for radionuclides, concentration of contaminated airborne particulates, ingested amount of contaminated material, and amount of metal released through the stack. Equations relating doses to tabular values and these source terms are developed, and hypothetical sample calculations are given. Assumptions, approximations, and limitations of the methods are discussed as well as nonroutine operations and nonradioactive hazards

  14. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ridyard, A

    2000-07-01

    The 'Erythemal Action Spectrum' shows an increase of 10{sup 3} in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  15. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    International Nuclear Information System (INIS)

    Ridyard, A.

    2000-01-01

    The 'Erythemal Action Spectrum' shows an increase of 10 3 in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  16. How Radiation Oncologists Would Disclose Errors: Results of a Survey of Radiation Oncologists and Trainees

    International Nuclear Information System (INIS)

    Evans, Suzanne B.; Yu, James B.; Chagpar, Anees

    2012-01-01

    Purpose: To analyze error disclosure attitudes of radiation oncologists and to correlate error disclosure beliefs with survey-assessed disclosure behavior. Methods and Materials: With institutional review board exemption, an anonymous online survey was devised. An email invitation was sent to radiation oncologists (American Society for Radiation Oncology [ASTRO] gold medal winners, program directors and chair persons of academic institutions, and former ASTRO lecturers) and residents. A disclosure score was calculated based on the number or full, partial, or no disclosure responses chosen to the vignette-based questions, and correlation was attempted with attitudes toward error disclosure. Results: The survey received 176 responses: 94.8% of respondents considered themselves more likely to disclose in the setting of a serious medical error; 72.7% of respondents did not feel it mattered who was responsible for the error in deciding to disclose, and 3.9% felt more likely to disclose if someone else was responsible; 38.0% of respondents felt that disclosure increased the likelihood of a lawsuit, and 32.4% felt disclosure decreased the likelihood of lawsuit; 71.6% of respondents felt near misses should not be disclosed; 51.7% thought that minor errors should not be disclosed; 64.7% viewed disclosure as an opportunity for forgiveness from the patient; and 44.6% considered the patient's level of confidence in them to be a factor in disclosure. For a scenario that could be considerable, a non-harmful error, 78.9% of respondents would not contact the family. Respondents with high disclosure scores were more likely to feel that disclosure was an opportunity for forgiveness (P=.003) and to have never seen major medical errors (P=.004). Conclusions: The surveyed radiation oncologists chose to respond with full disclosure at a high rate, although ideal disclosure practices were not uniformly adhered to beyond the initial decision to disclose the occurrence of the error.

  17. Computer aided in-flight radiation scanning

    International Nuclear Information System (INIS)

    Schmitzer, C.; Kloesch, W.

    1989-01-01

    The equipment consists of a radiation detecting instrument, a flight prospection probe and a portable PC. It is aimed at detection of ground radiation sources from a flying airplane, e.g. in case of radiation accident. 3 figs

  18. Calibration of a radiation survey meter using Cs-137 gamma source

    International Nuclear Information System (INIS)

    Khalid, R. O.

    2005-07-01

    The survey instrument smartIon was calibrated at the Secondary Standard Dosimetry Laboratory, Sudan Atomic Energy Commission, in terms of kerma, free in air using Cs-137 gamma radiation. All the calibrations were performed using the reference instrument spherical ionization chamber LS-01. This reference instrument has been calibrated at the International Atomic Energy Agency, Vienna for x-rays, 137 Cs and 60 Co gamma radiation. The air kerma calibration factors for the instrument were determined as the ratio of the dose rates obtained with the reference standard chamber LS-01 and the dose rates of the instrument under calibration. The uncertainties for the survey meter smartIon and another survey meter RADOS were obtained and the results compared with the uncertainty for the reference standard chamber. Also, the values of dose rates were obtained for various angles of the incident beam, by changing the angle by which the radiation was incident on the sensitive point of the instrument.(Author)

  19. Microcontroller based, ore grade measuring portable instruments for uranium mining industry

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Ore Face Scanning and Bore Hole Logging are important essential activities which are required to be carried out in any Uranium mining industry. Microcontroller based, portable instruments with built-in powerful embedded code for data acquisition (of Radiation counts) and Ore Grade calculations will become a handy measuring tool for miners. Nucleonix Systems has recently developed and made these two portable instruments available to UCIL, which are under use at Jaduguda and Narvapahar mines. Some of the important features of these systems are compact, light weight, portable, hand held, battery powered. Modes of Data Acquisition: CPS, CPM and ORE GRADE. Detector: Sensitive GM Tube. Choice of Adj. TC (Time Constant) in 'ORE GRADE', acquisition mode. Built-in automatic BG (Background) recording and subtraction provided to indicate net CPS, CPM or ore GRADE in PPM. Can store 1000 readings at users choice. Built-in RS232 serial port facilitates data downloading into PC. This paper focuses on design concepts and technical details for the above two products. (author)

  20. Nevada Test Site Area 25. Radiological survey and cleanup project, 1974-1983. Final report

    International Nuclear Information System (INIS)

    McKnight, R.K.; Rosenberry, C.E.; Orcutt, J.A.

    1984-01-01

    This report describes radiological survey, decontamination and decommissioning of the Nevada Test Site (NTS) Area 25 facilities and land areas incorporated in the Nuclear Rocket Development Station (NRDS). Buildings, facilities and support systems used after 1959 for nuclear reactor and engine testing were surveyed for the presence of radioactive contamination. The cleanup was part of the Surplus Facilities Management Program funded by the Department of Energy's Richland Operations Office. The radiological survey portion of the project encompassed portable instrument surveys and removable contamination surveys (swipe) for alpha and beta plus gamma radiation contamination of facilities, equipment and land areas. Soil sampling was also accomplished. The majority of Area 25 facilities and land areas have been returned to unrestricted use. Remaining radiologically contaminated areas are posted with warning signs and barricades. 12 figures

  1. Contemporary management of prostate cancer: a practice survey of Ontario genitourinary radiation oncologists

    International Nuclear Information System (INIS)

    Rodrigues, George; D'Souza, David; Crook, Juanita; Malone, Shawn; Sathya, Jinka; Morton, Gerard

    2003-01-01

    Objective: To survey radiation oncology practice in the utilization of hormonal and radiation therapy in the primary, adjuvant and salvage treatment of localized prostate cancer. Materials and methods: Genitourinary radiation oncologists practicing in Ontario were invited to participate in a practice survey examining staging, hormonal and radiation management, and radiation technique for a variety of common clinical scenarios. Background demographic information was collected on all respondents. The survey consisted of three cases relating to the hormonal/radiation management of low-, intermediate-, and high-risk prostate cancer as well as two adjuvant and one salvage post-prostatectomy scenarios. The survey response rate was 70% (26/37). Results: Clinicians were more likely to utilize laboratory and imaging studies for staging as the risk categorization increased. Low-risk disease was managed with radiation alone in 26/26 (70 Gy in 65%, 74-79.8 Gy in 35%). Intermediate-risk disease was managed with radiation (70 Gy in 46%, 74-79.8 Gy in 54%) with neoadjuvant hormones in 58%. All respondents managed high-risk disease with adjuvant hormones in addition to radiation therapy (70-71 Gy in 85%, and 76 Gy in 15%). In the pT3a, margin negative (PSA undetectable) scenario, most individuals would not recommend adjuvant radiation (73%). If margins were positive, 30% would still not recommend adjuvant radiation. In the salvage scenario (slowly rising PSA 4 years post-prostatectomy for pT2a close margin disease), all respondents would manage with radiation therapy. Hormones were not routinely recommended in the initial management of the adjuvant and salvage scenarios. Radiation doses utilized for both adjuvant and salvage treatment ranged from 60-70 Gy (median 66 Gy). Conclusions: General agreement exists for the management of low- and high-risk disease and in the post-prostatectomy salvage setting. Use of dose-escalation and neoadjuvant hormones in the intermediate

  2. Portable battery-free charger for radiation dosimeters

    International Nuclear Information System (INIS)

    Manning, F.W.

    1984-01-01

    This invention is a novel portable charger for dosimeters of the electrometer type. The charger does not require batteries or piezoelectric crystals and is of rugged construction. In a preferred embodiment, the charge includes a housing which carries means for mounting a dosimeter to be charged. The housing also includes contact means for impressing a charging voltage across the mounted dosimeter. Also, the housing carries a trigger for operating a charging system mounted in the housing. The charging system includes a magnetic loop including a permanent magnet for establishing a magnetic field through the loop. A segment of the loop is coupled to the trigger for movement thereby to positions opening and closing the loop. A coil inductively coupled with the loop generates coil-generated voltage pulses when the trigger is operated to open and close the loop. The charging system includes an electrical circuit for impressing voltage pulses from the coil across a capacitor for integrating the pulses and applying the resulting integrated voltage across the above-mentioned contact means for charging the dosimeter

  3. Portable battery-free charger for radiation dosimeters

    Science.gov (United States)

    Manning, Frank W.

    1984-01-01

    This invention is a novel portable charger for dosimeters of the electrometer type. The charger does not require batteries or piezoelectric crystals and is of rugged construction. In a preferred embodiment, the charge includes a housing which carries means for mounting a dosimeter to be charged. The housing also includes contact means for impressing a charging voltage across the mounted dosimeter. Also, the housing carries a trigger for operating a charging system mounted in the housing. The charging system includes a magnetic loop including a permanent magnet for establishing a magnetic field through the loop. A segment of the loop is coupled to the trigger for movement thereby to positions opening and closing the loop. A coil inductively coupled with the loop generates coil-generated voltage pulses when the trigger is operated to open and close the loop. The charging system includes an electrical circuit for impressing voltage pulses from the coil across a capacitor for integrating the pulses and applying the resulting integrated voltage across the above-mentioned contact means for charging the dosimeter.

  4. In Vivo Quantification of Lead in Bone with a Portable X-ray Fluorescence (XRF) System – Methodology and Feasibility

    Science.gov (United States)

    Nie, LH; Sanchez, S; Newton, K; Grodzins, L; Cleveland, RO; Weisskopf, MG

    2013-01-01

    This study was conducted to investigate the methodology and feasibility of developing a portable XRF technology to quantify lead (Pb) in bone in vivo. A portable XRF device was set up and optimal setting of voltage, current, and filter combination for bone lead quantification were selected to achieve the lowest detection limit. The minimum radiation dose delivered to the subject was calculated by Monte Carlo simulations. An ultrasound device was used to measure soft tissue thickness to account for signal attenuation, and an alternative method to obtain soft tissue thickness from the XRF spectrum was developed and shown to be equivalent to the ultrasound measurements (Intraclass Correlation Coefficient, ICC=0.82). We tested the correlation of in vivo bone lead concentrations between the standard KXRF technology and the portable XRF technology. There was a significant correlation between the bone lead concentrations obtained from the standard KXRF technology and those obtained from the portable XRF technology (ICC=0.65). The detection limit for the portable XRF device was about 8.4 ppm with 2 mm soft tissue thickness. The entrance skin dose delivered to the human subject was about 13 mSv and the total body effective dose was about 1.5 μSv and should pose a minimal radiation risk. In conclusion, portable XRF technology can be used for in vivo bone lead measurement with sensitivity comparable to the KXRF technology and good correlation with KXRF measurements. PMID:21242629

  5. Assessment of terrestrial gamma radiation dose rate (TGRD) of Kelantan State, Malaysia. Relationship between the geological formation and soil type to radiation dose rate

    International Nuclear Information System (INIS)

    Garba, N.N.; Gabdo, H.T.; Federal College of Education, Yola

    2014-01-01

    Terrestrial gamma radiation dose rates (TGRD) of Kelantan State were measured in situ using a portable [NaI(TI)] micro roentgen (μR) survey meter. The TGRD rates ranged between 44 and 500 nGy h -1 with a mean value of 209 ± 8 nGy h -1 . The distribution of these measurements in various districts of the state shows the statistically the influence of geology and soil types on the dose rate values. The data obtained could be used in formulating safety standard and radiological guidelines. (author)

  6. Improving radiation worker safety at the Chernobyl Shelter

    International Nuclear Information System (INIS)

    Vargo, G.J.; Korneev, A.A.

    2000-01-01

    The Shelter (i.e. 'sarcophagus') enclosing the remains of the Chernobyl Nuclear Power Plant Unit 4 that was destroyed in the April 1986 accident presents a unique radiological and nuclear safety challenge. The Chomobyl Shelter holds over 190 tons of irradiated nuclear fuel in the form of lava fuel containing masses and dust. Hazards include very high radiation, surface contamination and transient airborne radioactivity concentrations. A state-of-the-art radiation protection program is needed to support international efforts stabilize the Chornobyl Shelter, reduce the potential for major structural failure, minimize the consequences of a such an event, and develop a long-term strategy and study for its conversion into an environmentally safe site. This project consists of the first phase of efforts to transfer health physics technology necessary to support stabilization of the Chornobyl Shelter. Technical specifications for each major system and component were jointly developed by staff from the U.S. Department of Energy's Pacific Northwest National Laboratory and the Chornobyl Shelter. Major elements of this technology transfer include equipment for external dose control (electronic dosimeters, thermoluminescent dosimeter (TLD) system, portable radiation survey instruments, and area radiation monitors), internal dose control (whole body counter, bioassay system design and technical support), health physics training, and other radiological technical support. A work planning system that includes the capability to collect data such as radiological surveys, photographs, video clips, and other data, was developed from a system demonstrated at the U.S. Department of Energy's Hanford Site. An access control system similar to one used at several commercial nuclear facilities in the U.S. was converted for bilingual support (Russian and English). Technology for improving contamination control includes HEPA-ventilation and vacuum cleaner systems, semi-permanent and portable

  7. Portable treatment systems study

    Energy Technology Data Exchange (ETDEWEB)

    Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

    1997-03-01

    In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas.

  8. Portable treatment systems study

    International Nuclear Information System (INIS)

    Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

    1997-03-01

    In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas

  9. Evaluation of methods to calibrate radiation survey meters

    International Nuclear Information System (INIS)

    Robinson, R.C.; Arbeau, N.D.

    1987-04-01

    Calibration requirements for radiation survey meters used in industrial radiography have been reviewed. Information obtained from a literature search, discussions with CSLD inspectors and firms performing calibrations has been considered. Based on this review a set of minimum calibration requirements was generated which, when met, will determine that the survey meter is suited for measurements described in the current AEC Regulations that apply to industrial radiography equipment. These requirements are presented in this report and may be used as guidelines for evaluating calibration methods proposed or in use in industry. 39 refs

  10. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  11. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  12. Application of portable XRF and VNIR sensors for rapid assessment of soil heavy metal pollution

    OpenAIRE

    Hu, Bifeng; Chen, Songchao; Hu, Jie; Xia, Fang; Xu, Junfeng; Li, Yan; Shi, Zhou

    2017-01-01

    Rapid heavy metal soil surveys at large scale with high sampling density could not be conducted with traditional laboratory physical and chemical analyses because of the high cost, low efficiency and heavy workload involved. This study explored a rapid approach to assess heavy metals contamination in 301 farmland soils from Fuyang in Zhejiang Province, in the southern Yangtze River Delta, China, using portable proximal soil sensors. Portable X-ray fluorescence spectroscopy (PXRF) was used to ...

  13. Dosimetry of the portable blood irradiator

    International Nuclear Information System (INIS)

    Roberson, P.L.; Hungate, F.P.; Reece, W.D.; Tanner, J.E.

    1985-08-01

    A portable blood irradiator was developed at the Pacific Northwest Laboratory to evaluate the effects of chronic irradiation of the blood in suppressing graft rejection. The irradiator, designed to be worn on the arm or leg and be surgically connected in an arterio-venous shunt, uses beta radiation from activated thulium imbedded in a vitreous carbon matrix to reduce the number of lymphocytes circulating in the blood. The dose and energy spectra relative to the distance from and position around a prototype irradiator were measured by thermoluminescent dosimeters, ion chambers and photon spectroscopy. With computer simulations using those measurements, the shielding was redesigned to minimize the radiation dose to the patient and to the attending personnel and to minimize the weight of the irradiator. The new shielding design was incorporated into a new prototype, and the dose and spectral measurements were repeated, which confirmed the design improvements. 10 refs., 11 figs

  14. Results of the Association of Directors of Radiation Oncology Programs (ADROP) Survey of Radiation Oncology Residency Program Directors

    International Nuclear Information System (INIS)

    Harris, Eleanor; Abdel-Wahab, May; Spangler, Ann E.; Lawton, Colleen A.; Amdur, Robert J.

    2009-01-01

    Purpose: To survey the radiation oncology residency program directors on the topics of departmental and institutional support systems, residency program structure, Accreditation Council for Graduate Medical Education (ACGME) requirements, and challenges as program director. Methods: A survey was developed and distributed by the leadership of the Association of Directors of Radiation Oncology Programs to all radiation oncology program directors. Summary statistics, medians, and ranges were collated from responses. Results: Radiation oncology program directors had implemented all current required aspects of the ACGME Outcome Project into their training curriculum. Didactic curricula were similar across programs nationally, but research requirements and resources varied widely. Program directors responded that implementation of the ACGME Outcome Project and the external review process were among their greatest challenges. Protected time was the top priority for program directors. Conclusions: The Association of Directors of Radiation Oncology Programs recommends that all radiation oncology program directors have protected time and an administrative stipend to support their important administrative and educational role. Departments and institutions should provide adequate and equitable resources to the program directors and residents to meet increasingly demanding training program requirements.

  15. Development of regulatory technologies of key issues of radiation sources in the medical and industrial fields

    International Nuclear Information System (INIS)

    Lee, Jae Seong; Kim, Byung Soo; Ku, Bon Chul

    2006-08-01

    The aim of this research is to provide with rational bases to address the key issues raising up during the expansion of RI/RG usage in the medical and industrial fields, thus eventually contribute to enhancing the effectiveness of national regulatory systems. Related key issues that are introduced in the medical and industrial fields are analyzed and some outcomes are produced. The following results are attained. - Estimation Methodology Development of Regulatory Effects for the Use of Radioactive Substances, - Survey on Domestic Status of Nuclear Materials and Review on Domestic/Foreign Regulatory System for Nuclear Materials Regulation, - Comparative Analysis of KSTAR and Fusion Facilities of Advanced Countries, - Radiological Characteristics of Proton Therapy and Analysis of Foreign Cases and Systems, - Detection and Safety Analysis of Leak Radiation of High Energy Medical Generators, - Survey and Analysis on Usage and Requirements of Sealed Sources, - Incidents/Accidents Reporting System for RI-related Facilities, - Development of Audio-Visual Education Materials for Radiation Workers, - Development of Major Safety Procedures for Portable RIs, - Expansion of Existing DB for Radiation Devices including New Domestic Ones, - Survey of Foreign Status of Quality Maintenance System for Radiation equipment

  16. A National Radiation Oncology Medical Student Clerkship Survey: Didactic Curricular Components Increase Confidence in Clinical Competency

    Energy Technology Data Exchange (ETDEWEB)

    Jagadeesan, Vikrant S. [Department of Radiation and Cellular Oncology, Pritzker School of Medicine, University of Chicago, Chicago, Illinois (United States); Raleigh, David R. [Department of Radiation Oncology, School of Medicine, University of California–San Francisco, San Francisco, California (United States); Koshy, Matthew; Howard, Andrew R.; Chmura, Steven J. [Department of Radiation and Cellular Oncology, Pritzker School of Medicine, University of Chicago, Chicago, Illinois (United States); Golden, Daniel W., E-mail: dgolden@radonc.uchicago.edu [Department of Radiation and Cellular Oncology, Pritzker School of Medicine, University of Chicago, Chicago, Illinois (United States)

    2014-01-01

    Purpose: Students applying to radiation oncology residency programs complete 1 or more radiation oncology clerkships. This study assesses student experiences and perspectives during radiation oncology clerkships. The impact of didactic components and number of clerkship experiences in relation to confidence in clinical competency and preparation to function as a first-year radiation oncology resident are evaluated. Methods and Materials: An anonymous, Internet-based survey was sent via direct e-mail to all applicants to a single radiation oncology residency program during the 2012-2013 academic year. The survey was composed of 3 main sections including questions regarding baseline demographic information and prior radiation oncology experience, rotation experiences, and ideal clerkship curriculum content. Results: The survey response rate was 37% (70 of 188). Respondents reported 191 unique clerkship experiences. Of the respondents, 27% (19 of 70) completed at least 1 clerkship with a didactic component geared towards their level of training. Completing a clerkship with a didactic component was significantly associated with a respondent's confidence to function as a first-year radiation oncology resident (Wilcoxon rank–sum P=.03). However, the total number of clerkships completed did not correlate with confidence to pursue radiation oncology as a specialty (Spearman ρ P=.48) or confidence to function as a first year resident (Spearman ρ P=.43). Conclusions: Based on responses to this survey, rotating students perceive that the majority of radiation oncology clerkships do not have formal didactic curricula. Survey respondents who completed a clerkship with a didactic curriculum reported feeling more prepared to function as a radiation oncology resident. However, completing an increasing number of clerkships does not appear to improve confidence in the decision to pursue radiation oncology as a career or to function as a radiation oncology resident. These

  17. A national radiation oncology medical student clerkship survey: didactic curricular components increase confidence in clinical competency.

    Science.gov (United States)

    Jagadeesan, Vikrant S; Raleigh, David R; Koshy, Matthew; Howard, Andrew R; Chmura, Steven J; Golden, Daniel W

    2014-01-01

    Students applying to radiation oncology residency programs complete 1 or more radiation oncology clerkships. This study assesses student experiences and perspectives during radiation oncology clerkships. The impact of didactic components and number of clerkship experiences in relation to confidence in clinical competency and preparation to function as a first-year radiation oncology resident are evaluated. An anonymous, Internet-based survey was sent via direct e-mail to all applicants to a single radiation oncology residency program during the 2012-2013 academic year. The survey was composed of 3 main sections including questions regarding baseline demographic information and prior radiation oncology experience, rotation experiences, and ideal clerkship curriculum content. The survey response rate was 37% (70 of 188). Respondents reported 191 unique clerkship experiences. Of the respondents, 27% (19 of 70) completed at least 1 clerkship with a didactic component geared towards their level of training. Completing a clerkship with a didactic component was significantly associated with a respondent's confidence to function as a first-year radiation oncology resident (Wilcoxon rank-sum P=.03). However, the total number of clerkships completed did not correlate with confidence to pursue radiation oncology as a specialty (Spearman ρ P=.48) or confidence to function as a first year resident (Spearman ρ P=.43). Based on responses to this survey, rotating students perceive that the majority of radiation oncology clerkships do not have formal didactic curricula. Survey respondents who completed a clerkship with a didactic curriculum reported feeling more prepared to function as a radiation oncology resident. However, completing an increasing number of clerkships does not appear to improve confidence in the decision to pursue radiation oncology as a career or to function as a radiation oncology resident. These results support further development of structured didactic

  18. A National Radiation Oncology Medical Student Clerkship Survey: Didactic Curricular Components Increase Confidence in Clinical Competency

    International Nuclear Information System (INIS)

    Jagadeesan, Vikrant S.; Raleigh, David R.; Koshy, Matthew; Howard, Andrew R.; Chmura, Steven J.; Golden, Daniel W.

    2014-01-01

    Purpose: Students applying to radiation oncology residency programs complete 1 or more radiation oncology clerkships. This study assesses student experiences and perspectives during radiation oncology clerkships. The impact of didactic components and number of clerkship experiences in relation to confidence in clinical competency and preparation to function as a first-year radiation oncology resident are evaluated. Methods and Materials: An anonymous, Internet-based survey was sent via direct e-mail to all applicants to a single radiation oncology residency program during the 2012-2013 academic year. The survey was composed of 3 main sections including questions regarding baseline demographic information and prior radiation oncology experience, rotation experiences, and ideal clerkship curriculum content. Results: The survey response rate was 37% (70 of 188). Respondents reported 191 unique clerkship experiences. Of the respondents, 27% (19 of 70) completed at least 1 clerkship with a didactic component geared towards their level of training. Completing a clerkship with a didactic component was significantly associated with a respondent's confidence to function as a first-year radiation oncology resident (Wilcoxon rank–sum P=.03). However, the total number of clerkships completed did not correlate with confidence to pursue radiation oncology as a specialty (Spearman ρ P=.48) or confidence to function as a first year resident (Spearman ρ P=.43). Conclusions: Based on responses to this survey, rotating students perceive that the majority of radiation oncology clerkships do not have formal didactic curricula. Survey respondents who completed a clerkship with a didactic curriculum reported feeling more prepared to function as a radiation oncology resident. However, completing an increasing number of clerkships does not appear to improve confidence in the decision to pursue radiation oncology as a career or to function as a radiation oncology resident. These results

  19. Portable Medical Laboratory Applications Software

    OpenAIRE

    Silbert, Jerome A.

    1983-01-01

    Portability implies that a program can be run on a variety of computers with minimal software revision. The advantages of portability are outlined and design considerations for portable laboratory software are discussed. Specific approaches for achieving this goal are presented.

  20. Portable long trace profiler: Concept and solution

    Science.gov (United States)

    Qian, Shinan; Takacs, Peter; Sostero, Giovanni; Cocco, Daniele

    2001-08-01

    Since the early development of the penta-prism long trace profiler (LTP) and the in situ LTP, and following the completion of the first in situ distortion profile measurements at Sincrotrone Trieste (ELETTRA) in Italy in 1995, a concept was developed for a compact, portable LTP with the following characteristics: easily installed on synchrotron radiation beam lines, easily carried to different laboratories around the world for measurements and calibration, convenient for use in evaluating the LTP as an in-process tool in the optical workshop, and convenient for use in temporarily installation as required by other special applications. The initial design of a compact LTP optical head was made at ELETTRA in 1995. Since 1997 further efforts to reduce the optical head size and weight, and to improve measurement stability have been made at Brookhaven National Laboratory. This article introduces the following solutions and accomplishments for the portable LTP: (1) a new design for a compact and very stable optical head, (2) the use of a small detector connected to a laptop computer directly via an enhanced parallel port, and there is no extra frame grabber interface and control box, (3) a customized small mechanical slide that uses a compact motor with a connector-sized motor controller, and (4) the use of a laptop computer system. These solutions make the portable LTP able to be packed into two laptop-size cases: one for the computer and one for the rest of the system.

  1. Portable long trace profiler: Concept and solution

    International Nuclear Information System (INIS)

    Qian, Shinan; Takacs, Peter; Sostero, Giovanni; Cocco, Daniele

    2001-01-01

    Since the early development of the penta-prism long trace profiler (LTP) and the in situ LTP, and following the completion of the first in situ distortion profile measurements at Sincrotrone Trieste (ELETTRA) in Italy in 1995, a concept was developed for a compact, portable LTP with the following characteristics: easily installed on synchrotron radiation beam lines, easily carried to different laboratories around the world for measurements and calibration, convenient for use in evaluating the LTP as an in-process tool in the optical workshop, and convenient for use in temporarily installation as required by other special applications. The initial design of a compact LTP optical head was made at ELETTRA in 1995. Since 1997 further efforts to reduce the optical head size and weight, and to improve measurement stability have been made at Brookhaven National Laboratory. This article introduces the following solutions and accomplishments for the portable LTP: (1) a new design for a compact and very stable optical head, (2) the use of a small detector connected to a laptop computer directly via an enhanced parallel port, and there is no extra frame grabber interface and control box, (3) a customized small mechanical slide that uses a compact motor with a connector-sized motor controller, and (4) the use of a laptop computer system. These solutions make the portable LTP able to be packed into two laptop-size cases: one for the computer and one for the rest of the system

  2. Personal Radiation Detector Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Chris A. Hodge, Ding Yuan, Raymond P. Keegan, Michael A. Krstich

    2007-01-01

    Following the success of the Anole test of portable detection system, the U.S. Department of Homeland Security (DHS) Domestic Nuclear Detection Office organized a test and evaluation campaign for personal radiation detectors (PRDs), also known as 'Pagers'. This test, 'Bobcat', was conducted from July 17 to August 8, 2006, at the Nevada Test Site. The Bobcat test was designed to evaluate the performance of PRDs under various operational scenarios, such as pedestrian surveying, mobile surveying, cargo container screening, and pedestrian chokepoint monitoring. Under these testing scenarios, many operational characteristics of the PRDs, such as gamma and neutron sensitivities, positive detection and false alarm rates, response delay times, minimum detectable activities, and source localization errors, were analyzed. This paper will present the design, execution, and methodologies used to test this equipment for the DHS

  3. Microprocessor based mobile radiation survey system

    International Nuclear Information System (INIS)

    Gilbert, R.W.; McCormack, W.D.

    1983-12-01

    A microprocessor-based system has been designed and constructed to enhance the performance of routine radiation surveys on roads within the Hanford site. This device continually monitors system performance and output from four sodium iodide detectors mounted on the rear bumper of a 4-wheel drive truck. The gamma radiation count rate in counts-per-second is monitored, and a running average computed, with the results compared to predefined limits. If an abnormal instantaneous or average count rate is detected, an alarm is sounded with responsible data displayed on a liquid crystal panel in the cab of the vehicle. The system also has the capability to evaluate detector output using multiple time constants and to perform more complex tests and comparison of the data. Data can be archived for later analysis on conventional chart recorders or stored in digital form on magnetic tape or other digital storage media. 4 figures

  4. Radiation exposures of workers resulting from the transport of gamma radiography sources in Germany

    International Nuclear Information System (INIS)

    Sentuc, F.N.; Schwarz, G.

    2006-01-01

    Gamma radiation sources are widely used for industrial purposes e.g. for non-destructive material testing. Many of these sources are permanently installed at a facility within instruments e.g. for level or thickness gauging. Other radioactive sources are implemented in portable devices for industrial gamma radiography which have to be carried to the various remote usage sites. In Germany, approximately 20 000 - 25 000 shipments of gamma radiography sources are proceeding annually on public transport routes. Since routine radiation monitoring programmes do not permit task-specific determination of occupational doses e.g. doses incurred during the movement phase and handling related doses, work has been carried out with the objective to determine the radiation exposures of the personnel attributable to transportation. For this purpose, a survey was launched in 2005 collecting data about e.g. the number and conditions of transports, the activity and type of transported radiation sources and the radiation level within the driver's cab to allow a dose assessment to be made for transport workers. The results of this survey covering the most important companies for gamma radiography services in Germany are presented in this paper. (authors)

  5. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  6. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  7. Survey of Radiation Oncology Centres in Australia: report of the radiation oncology treatment quality program

    International Nuclear Information System (INIS)

    Klybaba, M.; Kenny, L.; Kron, T.; Harris, J.; O'Brien, P.

    2009-01-01

    Full text: One of the first steps towards the development of a comprehensive quality program for radiation oncology in Australia has been a survey of practice. This paper reports on the results of the survey that should inform the development of standards for radiation oncology in Australia. A questionnaire of 108 questions spanning aspects of treatment services, equipment, staff, infrastructure and available quality systems was mailed to all facilities providing radiation treatment services in Australia (n = 45). Information of 42 sites was received by June 2006 providing data on 113 operational linear accelerators of which approximately 2/3 are equipped with multi-leaf collimators. More than 75% of facilities were participating in a formal quality assurance (QA) system, with 63% following a nationally or internationally recognised system. However, there was considerable variation in the availability of policies and procedures specific to quality aspects, and the review of these. Policies for monitoring patient waiting times for treatment were documented at just 71% of all facilities. Although 85% of all centres do, in fact, monitor machine throughput, the number and types of efficiency measures varied markedly, thereby limiting the comparative use of these results. Centres identified workload as the single most common factor responsible for limiting staff involvement in both QA processes and clinical trial participation. The data collected in this 'snapshot' survey provide a unique and comprehensive baseline for future comparisons and evaluation of changes

  8. Mobile radiation monitoring of Delhi for the prevention of malicious acts during the Common Wealth Games (CWG-2010)

    International Nuclear Information System (INIS)

    Saindane, Shashank S.; Chatterjee, M.K.; Romal, Jis; Pradeepkumar, K.S.; Singh, B.R.

    2012-01-01

    Radioactive sources are widely used in industry, research, agriculture and medical applications. In spite of various measures adopted for ensuring the safety and security of these sources, similar to Mayapuri incident, many cases of lost, misplaced, stolen radioactive sources and inadvertent radiation exposure due to radiological emergencies are reported world over. In the aftermath of the attack on the World Trade Center 2001, malicious acts using radioactive material is considered as a threat for which prevention and preparedness for response are recommended by IAEA. Hence radiation monitoring of all related area prior to and during Major Public Events (MPEs) like Olympics, World cup football etc are implemented by many nations for prevention and preparedness to such radiological threats/emergencies. Department of Atomic Energy (DAE) through their Emergency Response Centres planned and executed detailed radiation monitoring programme for the Delhi Common Wealth Games (CWG 2010) which covered all CWG stadiums. Commonwealth village etc. In addition to DAE emergency response teams of 15 members in readiness, source recovery and shielding facilities, Portable Personnel Decontamination Unit (PPDU), Radiation monitors, Protective gears, Aerial Gamma Spectrometry System (AGSS for Aerial surveys) etc. were maintained at two DAE control rooms. This paper discusses the mobile radiation monitoring carried out on Delhi city roads with the help of various state-of-the-art monitoring systems to detect the presence or movement of any orphan sources. The mobile radiation monitoring was focused on main road networks connecting to stadiums, areas surrounding stadiums, airport and Games village. For this state-of-the-art systems like Portable Mobile Gamma Spectrometry System (PMGSS), Portable Radiation Scanner (PRS), Compact Radiation Monitoring System integrated with GPS, GSM based Radiation Monitoring System (GRaMS), Gammatracers, Selection and placement of different monitoring

  9. Results of the 1993 Association of Residents in Radiation Oncology survey

    International Nuclear Information System (INIS)

    Ling, Stella M.; Flynn, Daniel F.

    1996-01-01

    In 1993, the Association of Residents in Radiation Oncology (ARRO) conducted its tenth annual survey of all residents training in radiation oncology in the United States. The characteristics of current residents are described. Factors influencing the choice of Radiation Oncology as a medical specialty, and posttraining career plans were identified. Residents raised issues on the adequacy of training, problems in work routine, and expressed concerns about board certification and recertification, and about decreased future practice opportunities

  10. Survey of radiation protection, radiation transport, and shielding information needs of the nuclear power industry. Final report

    International Nuclear Information System (INIS)

    Maskewitz, B.F.; Trubey, D.K.; Roussin, R.W.; McGill, B.L.

    1976-04-01

    The Radiation Shielding Information Center (RSIC) is engaged in a program to seek out, organize, and disseminate information in the area of radiation transport, shielding, and radiation protection. This information consists of published literature, nuclear data, and computer codes and advanced analytical techniques required by ERDA, its contractors, and the nuclear power industry to improve radiation analysis and computing capability. Information generated in this effort becomes a part of the RSIC collection and/or data base. The purpose of this report on project 219-1 is to document the results of the survey of information and computer code needs of the nuclear power industry in the area of radiation analysis and protection

  11. Survey of radiation protection, radiation transport, and shielding information needs of the nuclear power industry. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Maskewitz, B.F.; Trubey, D.K.; Roussin, R.W.; McGill, B.L.

    1976-04-01

    The Radiation Shielding Information Center (RSIC) is engaged in a program to seek out, organize, and disseminate information in the area of radiation transport, shielding, and radiation protection. This information consists of published literature, nuclear data, and computer codes and advanced analytical techniques required by ERDA, its contractors, and the nuclear power industry to improve radiation analysis and computing capability. Information generated in this effort becomes a part of the RSIC collection and/or data base. The purpose of this report on project 219-1 is to document the results of the survey of information and computer code needs of the nuclear power industry in the area of radiation analysis and protection.

  12. Proposed Philippine radiation-sterilization plant, and a survey of market potential

    International Nuclear Information System (INIS)

    Singson, C.C.; Ibe, L.D.

    1975-01-01

    The paper deals with a study to assess the market potential of radiation sterilization in the Philippines. A market survey conducted with the technical assistance of an IAEA expert from India shows that most of the pharmaceutical industries engaged in the manufacture of medical products unanimously agree that there is an urgent need for a centralized radiation sterilization plant to meet the demands of sterilization of most of their products and packaging materials. The authorities of the government and some of the private hospitals surveyed are also very keen for the establishment of a sterilization facility since most modern medical products and devices are made of heat-sensitive thermoplastics which cannot be heat or steam sterilized. Availability of sterile products will help improve the public health standards of the population. The scope of the utilization of a radiation-sterilization facility in Diliman Quezon City is also discussed. (author)

  13. Factors influencing perception of radiation risk in people around Chernobyl. Survey in Ukraine

    International Nuclear Information System (INIS)

    Shibata, Yoshisada

    2010-01-01

    To elucidate the factors influencing perception of radiation risk in people around Chernobyl, we conducted a survey in Ukraine using self-administered questionnaire consisting of 37 questions including 5 questions about radiation contamination of their living places and foodstuffs, and 9 questions about radiation and risk. The subjects were high school or university students and their parents living in Zhytomyr, Rivne, Kirovograd and Odesa regions, and Slavutych city. In each of these 5 survey areas, we distributed 330 questionnaires to students and their parents, respectively. A total of 1,536 students (93%) responded to the questionnaire, while in parents only 861 (52%) responded. In students, a significant difference by place of residence was observed in the frequency of those regarding radiation accident or radon in dwellings being highly dangerous. (author)

  14. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  15. Radiation survey of mobile and wireless technology masts in public places in Kaduna metropolis Nigeria

    International Nuclear Information System (INIS)

    Onoh, N. I.; Ogbanje, G. O.; Jonah, S. A.

    2014-01-01

    Work was done to measure radiation exposure of the populace in Kaduna metropolis from radiation emitted from global satellite communication masts. Base stations were surveyed in residential, school and office areas. Parameters sampled include the electric field strength, magnetic field strength, power density and ionizing radiation dose rate of the 20 surveyed masts belonging to four service providers. The instruments deployed include the Rf- EMF strength meter Model 480836 used to measure the first three parameters and Radiation Monitor Radex RD 1503 used to determine the forth parameter. The result obtained in this work was compared with the limits set by international regulatory bodies. Our result shows that electromagnetic and ionizing radiation exposures from the surveyed masts are far below the standard limits. Based on this, the population in Kaduna metropolis is not subjected to any adverse health effects from the Global System of Mobile Communication/Universal Mobile Telecommunication System masts at the moment.

  16. Survey of Michigan dentists and radiation oncologists on oral care of patients undergoing head and neck radiation therapy.

    Science.gov (United States)

    Patel, Yoshita; Bahlhorn, Hannah; Zafar, Saniya; Zwetchkenbaum, Samuel; Eisbruch, Avraham; Murdoch-Kinch, Carol Anne

    2012-07-01

    Oral complications of radiation therapy for head and neck cancer (HNC) are associated with a significant decline in oral health-related quality of life (OHQOL). The dentist, working with the radiation oncologist and the rest of the health care team, plays an important role in the prevention and management of these complications, but patients do not always receive care consistent with current guidelines. This study investigated barriers to recommended care. There is variability in knowledge and practice among dentists and radiation oncologists regarding the dental management of patients treated with head and neck radiotherapy (HNRT), and inadequate communication and collaboration between members of the patient's health care team contribute to inconsistencies in application of clinical care guidelines. There is on interest and need for continuing dental (CDE) and medical education (CME) on this topic. A questionnaire was developed to assess dentists' knowledge and practice of dental management of HNC patients and their interest in CDE on this topic. All members of the Michigan Dental Association (MDA) with email addresses were asked to complete the survey online, and a random sample of MDA members without email addresses was invited to complete a paper version of the same survey. All Michigan members of the American Society for Radiation Oncology (ASTRO) were invited to complete an online version of the survey modified for radiation oncologists. The response rate for dentists was 47.9% and radiation oncologists was 22.3%. Of the dentists who responded, 81% reported that a major barrier to providing dental treatment before radiotherapy was a lack of time between initial dental consultation and the start of radiation; inadequate communication between health care providers was blamed most frequently for this. Ten percent of the dentists and 25% of the radiation oncologists reported that they did not treat HNC patients because they lacked adequate training, and 55% of

  17. Applications of non-cryogenic portable EDXRF systems in archaeometry

    International Nuclear Information System (INIS)

    Cesareo, R.; Castellano, A.; Dabrowski, A.

    1996-01-01

    In this paper the most relevant developments in the realisation of portable energy-dispersive X-ray fluorescence (EDXRF) equipments are discussed. In particular, the latest advances in non-cryogenic (Peltier cooled) X-ray detectors and miniaturised X-ray generators are shown. The energy resolution of the new detection systems is adequate to resolve the characteristic X-ray emission lines of contiguous elements. This small size and low power make the system ideal for portable instrumentation and have stimulated the development of small- and low-power X-ray generators which can be used for the excitation of fluorescence radiation in a broad energy range (5-40 keV). Finally, the use of EDXRF related to archaeometric research (pigments in ancient paintings and major elements in the metal alloys) is emphasised. Recent results obtained with new HgI 2 and silicon PIN detector systems combined with miniaturised highly stable air-cooled X-ray generators are described. (orig.)

  18. Epidemiological surveys on the effects of low-level radiation dose: a comparative assessment

    International Nuclear Information System (INIS)

    Rose, K.S.B.

    1988-01-01

    In this report, the health effects of low-level doses of radiation are considered by reference to published epidemiological surveys. The work was carried out with three objectives in mind: 1. to provide a comprehensive and critical review of the subject; 2. to seek consistent indications of particular health effects by collating results and comparing with those from surveys at moderate-level doses; 3. to provide an authoritative view on the epidemiology of low-level radiation-induced health effects. Vol E (DRAFT A) is appended and contains group collation tables. Epidemiological surveys can be conveniently divided into four classes (A, B, C, D) according to the phase of life when irradiation occurs or the effect is diagnosed. The first of the classes (A) is addressed here; this class is concerned with possible effects arising from radiation received by a parent before conception. Possible effects of preconception irradiation were identified under four broad groupings. These are Down's syndrome, ''Indicators of Reproductive Damage'' (mainly Primary Sterility, Congenital Abnormalities, Sex Ratio, Fetal Mortality, Infant Mortality), Childhood Malignancies, and Chromosomal Changes in Abortuses. Information about each survey, and comparisons with results from moderate-level dose surveys, are contained in synopses that are set out in the Appendix. (author)

  19. Portable Instrumented Communication Library

    International Nuclear Information System (INIS)

    Geist, G.A.; Heath, M.T.; Peyton, B.W.; Worley, P.H.

    2001-01-01

    1 - Description of program or function: PICL is a subroutine library that can be used to develop parallel programs that are portable across several distributed-memory multi-processors. PICL provides a portable syntax for key communication primitives and related system calls. It also provides portable routines to perform certain widely- used, high-level communication operations, such as global broadcast and global summation. PICL provides execution tracing that can be used to monitor performance or to aid in debugging. 2 - Restrictions on the complexity of the problem: PICL is a compatibility library built on top of the native multiprocessor operating system and message passing primitives. Thus, the portability of PICL programs is not guaranteed, being a function of idiosyncrasies of the different platforms. Predictable differences are captured with standard error trapping routines. PICL is a research tool, not a production software system

  20. Results of the 2004 Association of Residents in Radiation Oncology (ARRO) Survey

    International Nuclear Information System (INIS)

    Patel, Shilpen; Jagsi, Reshma; Wilson, John; Frank, Steven; Thakkar, Vipul V.; Hansen, Eric K.

    2006-01-01

    Purpose: The aim of this study was to document adequacy of training, career plans after residency, use of the in-service examination, and motivation for choice of radiation oncology as a specialty. Methods and Materials: In 2004, the Association of Residents in Radiation Oncology (ARRO) conducted a nationwide survey of all radiation oncology residents in the United States. Results: The survey was returned by 297 residents (response rate, 54%). Of the respondents, 29% were female and 71% male. The most popular career choice was joining an established private practice (38%), followed by a permanent academic career (29%). Residents for whom a permanent academic career was not their first choice were asked whether improvements in certain areas would have led them to be more likely to pursue an academic career. The most commonly chosen factors that would have had a strong or moderate influence included higher salary (81%), choice of geographic location (76%), faculty encouragement (68%), and less time commitment (68%). Of respondents in the first 3 years of training, 78% believed that they had received adequate training to proceed to the next level of training. Of those in their fourth year of training, 75% believed that they had received adequate training to enter practice. Conclusions: Multiple factors affect the educational environment of physicians in training. Data describing concerns unique to resident physicians in radiation oncology are limited. The current survey was designed to explore a variety of issues confronting radiation oncology residents. Training programs and the Residency Review Committee should consider these results when developing new policies to improve the educational experiences of residents in radiation oncology

  1. Development of a portable x-ray tv camera set

    International Nuclear Information System (INIS)

    Panityotai, J.

    1990-01-01

    A portable X-ray T V camera set was developed using a 24 V battery as a power supply unit. The development aims at a non-film X-radiographic technique with low exposure radiation. The machine is able to catch one X-radiographic frame at a time with a resolution of 256 X 256 pixels under 64 gray scales. The investigation shows a horizontal resolution of 0.6 lines per millimeter and a vertical resolution of 0.7 lines per mi/limiter

  2. The current state of radiation education in schools and results of the opinion survey on radiation

    International Nuclear Information System (INIS)

    Murai, Kenji

    2013-01-01

    In 2008, a new guideline about radioactivity was added to the government guidelines for teaching junior high school science. Since then people involved with school education have been trying to spread correct information about radioactivity. On the other hand, people's confusion in the aftermath of the Fukushima Daiichi Nuclear Power Plant accident has clearly shown that people do not know much about radioactivity. Considering the situation, the author conducted an investigation about the current state of radiation education and carried out an opinion survey about radioactivity among adults. The investigation about education showed the following: (1) the nature of radiation, such as its permeability, and its uses were described in the government-approved textbooks; (2) basic knowledge, such as what are radiation effects, were described comprehensively in the supplementary reading recommendations made by the Ministry of Education, Culture, Sports, Science, and Technology; and (3) locale education committees created teaching materials such as guidance to present topics. The opinion survey had questions to judge: (1) current public understanding of radioactivity; (2) the degree of general information that people collected for themselves; (3) the degree of specific knowledge about radioactivity that people had; and (4) people's attitudes toward various problems with radioactivity in the environment. The results suggested that for radiation education the following items are important: (1) to learn that radioactivity exists in people's daily lives and is used safely in various field; (2) to get basic knowledge and better quantitative understanding of such things as radioactivity units, radiation dose and radiation effects; and (3) to acquire practical experience to use the information effectively. (author)

  3. [Advances of portable electrocardiogram monitor design].

    Science.gov (United States)

    Ding, Shenping; Wang, Yinghai; Wu, Weirong; Deng, Lingli; Lu, Jidong

    2014-06-01

    Portable electrocardiogram monitor is an important equipment in the clinical diagnosis of cardiovascular diseases due to its portable, real-time features. It has a broad application and development prospects in China. In the present review, previous researches on the portable electrocardiogram monitors have been arranged, analyzed and summarized. According to the characteristics of the electrocardiogram (ECG), this paper discusses the ergonomic design of the portable electrocardiogram monitor, including hardware and software. The circuit components and software modules were parsed from the ECG features and system functions. Finally, the development trend and reference are provided for the portable electrocardiogram monitors and for the subsequent research and product design.

  4. Prototype Pompa Air Portable Tenaga Surya

    OpenAIRE

    Taufik, Mohammad

    2016-01-01

    Makalah ini menyajikan purwarupa pompa air portable tenaga surya. Sistem pompa air portable terdiri atas pompa air, panel surya, solar charge controller, battery, solar frame, tiang, dan box. Sistem dapat dirangkai, sehingga bersifat portable. Pompa air portable ini berguna untuk kolam, irigasi, dan penyediaan air bersih. Hasil optimasi memberikan spesifikasi pompa air berdaya 50 Watt dan tegangan 12 VDC, solar panel berdaya 50 Wp, battery berkapasitas 50 Ah dan tegangan 12 VDC, da...

  5. A knowledge and awareness level survey of radiation protection among the radiation workers in Henan Province

    International Nuclear Information System (INIS)

    Cheng, Xiao-jun; Tian, Chong-bin; Zhang, Qin-fu; Liu, Cheng; Ding, Li

    2008-01-01

    Full text: Objective: To reveal the knowledge and awareness level of radiation protection among radiation workers in Henan province and to explore the methods to improve it. Methods: A questionnaire survey was carried out among 208 radiation workers. Results: The correct rate of the answer to radiation protection knowledge from radiation workers in Henan province is 53.78%. Most of them (88.9%) realized that it is important to protect patients and their companions. They adhere to the principles of justification of medial exposure and optimization of radiation protection and follow the management system of radiation protection. However, a few workers didn't follow the principles strictly. Sometime, during the radio diagnosis and radiotherapy services, the patients and their companions were not well protected from the radiation, and some patients were given unnecessary X-ray examine. Even worse, some workers did not attach importance to the regulations of radiation protection and disobey them frequently. Again, some hospital leaders disregard the regulation of radiation protection and didn't follow the regulation of health surveillance and radiation protection monitoring properly. And those behaviors and attitude, in fact, influence some workers' attitude to radiation protection. Conclusion: The level of radiation protection knowledge and awareness among the radiation workers in Henan province needs to be improved. It is necessary to strengthen radiation protection knowledge by strengthening training, and to improve safety awareness among the radiation staff, and, more important, the hospital leaders as well. (author)

  6. Application of portable XRF and VNIR sensors for rapid assessment of soil heavy metal pollution.

    Science.gov (United States)

    Hu, Bifeng; Chen, Songchao; Hu, Jie; Xia, Fang; Xu, Junfeng; Li, Yan; Shi, Zhou

    2017-01-01

    Rapid heavy metal soil surveys at large scale with high sampling density could not be conducted with traditional laboratory physical and chemical analyses because of the high cost, low efficiency and heavy workload involved. This study explored a rapid approach to assess heavy metals contamination in 301 farmland soils from Fuyang in Zhejiang Province, in the southern Yangtze River Delta, China, using portable proximal soil sensors. Portable X-ray fluorescence spectroscopy (PXRF) was used to determine soil heavy metals total concentrations while soil pH was predicted by portable visible-near infrared spectroscopy (PVNIR). Zn, Cu and Pb were successfully predicted by PXRF (R2 >0.90 and RPD >2.50) while As and Ni were predicted with less accuracy (R2 heavy metals contamination grades in farmland soils was conducted based on previous results; the Kappa coefficient was 0.87, which showed that the combination of PXRF and PVNIR was an effective and rapid method to determine the degree of pollution with soil heavy metals. This study provides a new approach to assess soil heavy metals pollution; this method will facilitate large-scale surveys of soil heavy metal pollution.

  7. Application of portable XRF and VNIR sensors for rapid assessment of soil heavy metal pollution

    Science.gov (United States)

    Hu, Bifeng; Chen, Songchao; Hu, Jie; Xia, Fang; Xu, Junfeng; Li, Yan; Shi, Zhou

    2017-01-01

    Rapid heavy metal soil surveys at large scale with high sampling density could not be conducted with traditional laboratory physical and chemical analyses because of the high cost, low efficiency and heavy workload involved. This study explored a rapid approach to assess heavy metals contamination in 301 farmland soils from Fuyang in Zhejiang Province, in the southern Yangtze River Delta, China, using portable proximal soil sensors. Portable X-ray fluorescence spectroscopy (PXRF) was used to determine soil heavy metals total concentrations while soil pH was predicted by portable visible-near infrared spectroscopy (PVNIR). Zn, Cu and Pb were successfully predicted by PXRF (R2 >0.90 and RPD >2.50) while As and Ni were predicted with less accuracy (R2 heavy metals contamination grades in farmland soils was conducted based on previous results; the Kappa coefficient was 0.87, which showed that the combination of PXRF and PVNIR was an effective and rapid method to determine the degree of pollution with soil heavy metals. This study provides a new approach to assess soil heavy metals pollution; this method will facilitate large-scale surveys of soil heavy metal pollution. PMID:28234944

  8. Portable gamma-irradiator - a modified model

    International Nuclear Information System (INIS)

    Pandev, I.N.; Christova, M.G.; Stefanov, S.D.; Gentchev, N.V.; Bakardjiev, S.T.; Christov, C.D.; Genov, D.T.

    1983-01-01

    A new modification of a portable gamma-irradiator has been designed with a relatively large irradiation volume, good homogeneity of the gamma field, small overall dimension, light biological shielding, and simple mechanics. It is possible to irradiate materials in two cylindrical volumes (3 l and 6 l) with different dose rates. 137 Cs is used as a radiation source. Depending on application, the irradiator can be charged with various total activities up to 6.66 x 10 14 Bq (18 kCi). The dose rate can be also charged up to the maximum by different positions of the source element. The gamma-irradiator can be used for scientific studies and for industrial purposes. (author)

  9. Improvement of portable computed tomography system for on-field applications

    Science.gov (United States)

    Sukrod, K.; Khoonkamjorn, P.; Tippayakul, C.

    2015-05-01

    In 2010, Thailand Institute of Nuclear Technology (TINT) received a portable Computed Tomography (CT) system from the IAEA as part of the Regional Cooperative Agreement (RCA) program. This portable CT system has been used as the prototype for development of portable CT system intended for industrial applications since then. This paper discusses the improvements in the attempt to utilize the CT system for on-field applications. The system is foreseen to visualize the amount of agarwood in the live tree trunk. The experiments adopting Am-241 as the radiation source were conducted. The Am-241 source was selected since it emits low energy gamma which should better distinguish small density differences of wood types. Test specimens made of timbers with different densities were prepared and used in the experiments. The cross sectional views of the test specimens were obtained from the CT system using different scanning parameters. It is found from the experiments that the results are promising as the picture can clearly differentiate wood types according to their densities. Also, the optimum scanning parameters were determined from the experiments. The results from this work encourage the research team to advance into the next phase which is to experiment with the real tree on the field.

  10. Improvement of Portable Computed Tomography System for On-field Applications

    International Nuclear Information System (INIS)

    Sukrod, K.; Khoonkamjorn, P.; Tippayakul, C.

    2014-01-01

    In 2010, Thailand Institute of Nuclear Technology (TINT) received a portable Computed Tomography (CT) system from IAEA as part of the Regional Cooperative Agreement (RCA) program. This portable CT system has been used as the prototype for development of portable CT system intended for industrial applications since then. This paper discusses the improvements in the attempt to utilize the CT system for on-field applications. The system is foreseen to visualize the amount of agarwood in the live tree trunk. The experiments adopting Am-241 as the radiation source were conducted. The Am-241 source was selected since it emits low energy gamma which should better distinguish small density differences of wood types. Test specimens made of timbers with different densities were prepared and used in the experiments. The cross sectional views of the test specimens were obtained from the CT system using different scanning parameters. It is found from the experiments that the results are promising as the picture can clearly differentiate wood types according to their densities. Also, the optimum scanning parameters were determined from the experiments. The results from this work encourage the research team to advance into the next phase which is to experiment with the real tree on the field.

  11. Improvement of portable computed tomography system for on-field applications

    International Nuclear Information System (INIS)

    Sukrod, K; Khoonkamjorn, P; Tippayakul, C

    2015-01-01

    In 2010, Thailand Institute of Nuclear Technology (TINT) received a portable Computed Tomography (CT) system from the IAEA as part of the Regional Cooperative Agreement (RCA) program. This portable CT system has been used as the prototype for development of portable CT system intended for industrial applications since then. This paper discusses the improvements in the attempt to utilize the CT system for on-field applications. The system is foreseen to visualize the amount of agarwood in the live tree trunk. The experiments adopting Am-241 as the radiation source were conducted. The Am-241 source was selected since it emits low energy gamma which should better distinguish small density differences of wood types. Test specimens made of timbers with different densities were prepared and used in the experiments. The cross sectional views of the test specimens were obtained from the CT system using different scanning parameters. It is found from the experiments that the results are promising as the picture can clearly differentiate wood types according to their densities. Also, the optimum scanning parameters were determined from the experiments. The results from this work encourage the research team to advance into the next phase which is to experiment with the real tree on the field. (paper)

  12. Radiation survey of first Hi-Art II Tomotherapy vault design in India

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Jamema, S.V.; Pai, Rajeshree; Sharma, P.K. Dash; Deshpande, Deepak D.

    2009-01-01

    A vault as per government-regulation compliance with adequate shielding needs was designed and constructed for Hi-Art II Tomotherapy machine being the first in India. Radiation measurements around this Tomotherapy treatment vault were carried out to check the shielding adequacy of the source housing and the vault. It was mandatory to get this un-conventional machine 'Type Approved' by Atomic Energy Regulatory Board (AERB) in India. The aim of this paper was to report on the radiation levels measured during the radiation survey carried out for this machine. The radiation levels in and around the vault were measured for stationary as well as rotational treatment procedures with the largest open field size (5 cm x 40 cm) at the isocenter with and without scattering medium. The survey was performed at three locations near each wall surrounding the vault as well. The leakage radiation from the source housing was measured both in the patient plane outside the treatment field and one meter distance from the source outside the patient plane. The radiation levels both for stationary as well as rotational procedures were within 1 mR/h. No significance difference was observed in the radiation levels measured for rotational procedures with and without scattering medium. The leakage radiation in the patient plane was found to be 0.04% (Tolerance 0.2%), while the head leakage was 0.007% (Tolerance 0.5%) of the dose rate at the isocenter. The treatment delivery with Tomotherapy does play safe radiation levels around the installation layout and also passes the leakage criteria as well.

  13. Software Engineering for Portability.

    Science.gov (United States)

    Stanchev, Ivan

    1990-01-01

    Discussion of the portability of educational software focuses on the software design and development process. Topics discussed include levels of portability; the user-computer dialog; software engineering principles; design techniques for student performance records; techniques of courseware programing; and suggestions for further research and…

  14. 46 CFR 169.743 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 169.743 Section 169.743... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.743 Portable magazine chests. Portable magazine chests must be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST...

  15. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  16. 'Radiation Fair' for 15 years in Osaka, Japan, and survey of the participants attitude toward radiation

    International Nuclear Information System (INIS)

    Furuta, Masakazu; Asano, Takeyoshi; Hayashi, Toshio; Hosokawa, Yasushi; Kakefu, Tomohisa; Nishihara, Hideaki

    1999-01-01

    We have been successfully operating 'Radiation Fair--The relationship between daily life and radiation--' during summer vacation season in August every year for 15 years in Osaka, the largest city of western Japan. The purpose of this event is radiation education of public including school kids through efficient information transfer of radiation and radiation-related technology. Currently we set up the space of it on a floor of Kintetsu Department Store, one of the major department stores in downtown Osaka and display various irradiated products available in our daily life together with explanatory panels. We have been devising various attractions as efficient information transfer media so that even elementary-school kids understand the basic knowledge of radiation and irradiation technologies. The number of participants has increased year by year until more than 20,000 in recent years. We distributed questionnaires to the visitors for recent 3 years to inquire their status toward radiation and irradiated products as well as impression toward the displays. The survey results suggest that school education may contribute to establish the public image toward 'radiation' as well as mass media. (author)

  17. 48 CFR 1837.170 - Pension portability.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1837... ADMINISTRATION SPECIAL CATEGORIES OF CONTRACTING SERVICE CONTRACTING Service Contracts-General 1837.170 Pension portability. (a) It is NASA's policy not to require pension portability in service contracts. However, pension...

  18. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  19. 46 CFR 108.651 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 108.651 Section 108.651... AND EQUIPMENT Equipment Markings and Instructions § 108.651 Portable magazine chests. Each portable magazine chest must be marked: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND FIRE AWAY” in letters at...

  20. The former Semipalatinsk Test Site survey by field γ-spectrometry method

    International Nuclear Information System (INIS)

    Pakhomov, S.A.; Dubasov, Yu.V.; Biryukov, E.I.; Gavrilin, S.S.; Ilyin, L.I.

    2001-01-01

    Full text: Field γ-spectrometry method is the most productive method of getting an information on gamma-irradiating radionuclides contents in objects under survey. For many years the Radium Institute was the most active participant of works on radiation survey of the Semipalatinsk Test Site, field γ-spectrometry method including. In field γ-spectrometry method realization the existence of corresponding apparatus, and methodic software is supposed to be allowing to carry out both measurement, recording of γ-spectrometry energetic characteristics in field conditions and final treatment (using corresponding physical models) ensuring obtaining the information on radionuclides' contents. Different variants of such apparatus were developed and made at the Radium Institute. Under conditions of complex spectral structure and high intensity existence a portable variant of Ge(Li)-detector spectrometer fed by alkaline accumulators and allowing to record a spectrum at high load was elaborated. For walk γ-survey in common with the University two variants of portable spectrometers 'Skif-3' were elaborated: one of them with a standard scintillation detector on the base of Nal(Ti) crystal, having the size of 63x63 mm, and the other is an 'X-ray' detector of large dimension on the base of CsI crystal with a diameter of 165 mm, designated for soft gamma-irradiation registration, 241 Am including. During 8 hours of independent works 'Skif-3' is able to record into internal memory up to 100 spectra with an exposure up to 9999 s. At 10 min exposure in its sensitivity of 241 Am finding (10 Bq/kg) a spectrometer 'Skif-3' excels a portable spectrometer 'InSpector' (Canberra) working with the exposure of 1 hour. For automobile measurements a car spectrometer was elaborated fed. from car board supply and having four detectors based on NaI crystals with the dimensions 200x110 mm and total volume of about 121. For express treatment of a 'Skif-3' spectrometer scintillation spectra special

  1. Code of practice and design principles for portable and transportable radiological protection systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1980-10-01

    The Code of Practice and design principles for portable and transportable radiological protection systems are presented in three parts. Part 1 specifies the requirement for Radiological Protection Instrumentation (RPI) including operational characteristics and the effects of both a radiation and non-radiation environment. Part 2 satisfies the requirement for RPI equipment as regards the overall design, the availability, the reliability, the information display, the human factors, the power supplies, the manufacture and quality assurance, the testing and the cost. Part 3 deals with the supply, location and operation of the RPI equipment. (U.K.)

  2. Induced radioactive nuclides of 10-MeV radiotherapy accelerators detected by using a portable Hp-Ge survey meter

    International Nuclear Information System (INIS)

    Fujibuchi, T.; Obara, S.; Yamaguchi, I.; Oyama, M.; Watanabe, H.; Sakae, T.; Katoh, K.

    2012-01-01

    The radioactivation of linear accelerator components for radiation therapy is interest for radiation protection in general, and particularly, when decommissioning these structures. The energy spectra of gamma rays emitted from the heads of two accelerator models, EXL-15SP and Clinac iX, after 10-MeV X-ray irradiation, were measured using a high-purity germanium semiconductor survey meter. After spectrum analyses, activities of 24 Na, 28 Al, 54 Mn, 56 Mn, 57 Ni, 58 Co, 60 Co, 64 Cu, 65 Zn, 122 Sb, 124 Sb, 181 W, 187 W, 196 Au, and 198 Au were detected. One centimetre deep dose-equivalent rate of the heads of the linear accelerator was measured using the survey meter. The dose rate decreased to ∼10 % of its initial rate after 1 week. Long-term activations were few, the radioactivity level was low, and a cooling time of several days was effective for reducing dose rate to an acceptable level for decommissioning. (authors)

  3. Batteryless magneto-driven portable radiac

    Science.gov (United States)

    Waechter, David A.; Bjarke, George O.; Trujillo, Faustin; Wolf, Michael A.; Umbarger, C. John

    1986-01-01

    A hand-powered alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Muller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.

  4. Contemporary management of stage i testicular seminoma: a survey of Canadian radiation oncologists

    Science.gov (United States)

    Samant, R.; Alomary, I.; Genest, P.; Eapen, L.

    2008-01-01

    Recently published studies clearly indicate that there are now several acceptable options for managing stage i testicular seminoma patients after orchiectomy. We therefore decided to survey Canadian radiation oncologists to determine how they currently manage such patients and to compare the results with previous surveys. Our results demonstrate that adjuvant single-agent chemotherapy is being considered as an option by an increasing proportion of radiation oncologists (although it is not considered the preferred option), the routine use of radiotherapy is declining, and surveillance is becoming increasingly popular and is recommended most often. PMID:18769613

  5. [Recent technical advances in portable oxygen delivery systems].

    Science.gov (United States)

    Machida, K; Kawabe, Y; Mori, M; Haga, T

    1992-08-01

    According to a Japanese national survey (June 30, 1990), the number of patients receiving home oxygen therapy (HOT) has been greater than 18,000 since March 1985, when HOT was first covered by health insurance. The oxygen concentrator, especially the molecular sieve type, is the most common method of delivery (more than 90%). In April 1988, the portable oxygen cylinder was acknowledged by health insurance, and the liquid oxygen supply system in April 1990. Three types of portable oxygen delivery systems are available; oxygen cyclinder, liquid oxygen system, and oxygen concentrator (membrane type), of which the oxygen cylinder is most commonly used. In our hospital, portable oxygen supply systems were used in 80% of 168 HOT cases in 1990, and the use of 400 L aluminum oxygen cylinders at a flow rate of 1-2 L/min has been most popular. There is an strong desire from patients for lighter portable oxygen supply system of longer duration. In 19 patients with chronic respiratory failure, we evaluated a newly designed demand oxygen delivery system (DODS), which weighs 2.4 kg including the DOD device (TER-20 Teijin), 1.1 L oxygen cylinder made of ultressor, nasal cannula, and carrier. Arterial blood gases at rest (room air) were PaO2 61.9 +/- 6.3 torr, PaCO2 63.8 +/- 9.4 torr and pH 7.40 +/- 0.04. A crossover trial was performed under three conditions; breathing room air with no weight, and pulse oxygen flow and continuous oxygen flow each carrying 2.4 kg of weight. Both 6 minute walking (E1) and walking on a slow speed treadmill (E2) were studied.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Perceptions and practices regarding women's vaginal health following radiation therapy: A survey of radiation oncologists practicing in the United States.

    Science.gov (United States)

    Kachnic, Lisa A; Bruner, Deborah W; Qureshi, Muhammad M; Russo, Gregory A

    Vaginal stenosis (VS) is a recognized complication of pelvic and vaginal radiation therapy (RT). A 26-item survey assessing the signs/symptoms, risk factors, diagnosis, prevention, treatment, and impact of VS on women's sexual health was distributed to radiation oncologists. Descriptive statistics were calculated. Chi-square tests examined differences in categorical responses. A total of 233 (10.5%) participants completed the entire survey. Twelve percent, 21%, and 68% report treating gynecologic (GYN) tumors only, non-GYN pelvic tumors only, or both, respectively. Regarding risk factors, 78% believed that VS can be caused by pelvic RT alone, 91% by vaginal brachytherapy alone, and 98% by combined pelvic RT and vaginal brachytherapy. Approximately one-half of respondents felt that being postmenopausal and having a hysterectomy before radiation therapy were risk factors for VS, whereas the other half felt that these were not risk factors. All respondents agreed that VS is a clinical diagnosis. Respondents indicated that VS symptoms include dyspareunia, vaginal pain, dryness, and/or bleeding (100%, 90%, 85%, and 72%, respectively); 65% indicated all 4. The most commonly recommended treatment for VS is vaginal dilator use. Radiation oncologists who treat GYN-only versus non-GYN cancers were more likely to perform a vaginal examination, to distribute written instructions regarding vaginal dilator use (P = .002), to have vaginal bleeding reported after RT (P = .001), and to refer patients to a sexual counselor (P = .007). Most providers (73%) expressed willingness to participate in prospective research on the diagnosis and treatment of VS. This is the first large-scale survey of radiation oncologists' perceptions and practices regarding VS. There is agreement among providers regarding the signs/symptoms of VS and strategies for its prevention/treatment using vaginal dilators. Further prospective and observational research is needed. This survey shows a willingness on

  7. A microprocessor based mobile radiation survey system

    International Nuclear Information System (INIS)

    Gilbert, R.W.; McCormack, W.D.

    1984-01-01

    A microprocessor-based system has been designed and constructed to enhance the performance of routine radiation surveys on roads within the Hanford site. This device continually monitors system performance and output from four sodium iodide detectors mounted on the rear bumper of a 4-wheel drive truck. The gamma radiation count rate in counts-per-second is monitored, and a running average computed, with the results compared to predefined limits. If an abnormal instantaneous or average count rate is detected, an alarm is sounded with responsible data displayed on a liquid crystal panel in the cab of the vehicle. The system also has the capability to evaluate detector output using multiple time constants and to perform more complex tests and comparison of the data. Data can be archived for later analysis on conventional chart recorders or stored in digital form on magnetic tape or other digital storage media

  8. Towards Application Portability on Blockchains

    OpenAIRE

    Shudo, Kazuyuki; Saito, Kenji

    2018-01-01

    We pose a fundamental problem of public blockchain, "incentive mismatch." It is an open problem, but application portability is a provisional solution to the problem. Portability is also a desirable property for an application on a private blockchain. It is not even clear to be able to define a common API for various blockchain middlewares, but it is possible to improve portability by reducing dependency on a blockchain. We present an example of such middleware designs that provide applicatio...

  9. Survey on radiation practices in Korea

    International Nuclear Information System (INIS)

    2006-06-01

    This book introduces outline of the survey with title, purpose, target, timing and composition of statistical data, explanation of terms. It consists of three parts about statistical tables. The first part has state of licensed organizations with number of licensed users by category of organizations, utilization by nuclides and by usage purpose and regional distribution of RI using Hospitals and clinics. The second parts deals with production and import with state of production and import, import by category of organizations and by nuclides and annual trend of production and import. The third part includes radiation safety management with collection of radioactive wastes and annual collect of sealed RI wastes.

  10. Portable bladder ultrasound: an evidence-based analysis.

    Science.gov (United States)

    2006-01-01

    The aim of this review was to assess the clinical utility of portable bladder ultrasound. TARGET POPULATION AND CONDITION Data from the National Population Health Survey indicate prevalence rates of urinary incontinence are 2.5% in women and 1.4 % in men in the general population. Prevalence of urinary incontinence is higher in women than men and prevalence increases with age. Identified risk factors for urinary incontinence include female gender, increasing age, urinary tract infections (UTI), poor mobility, dementia, smoking, obesity, consuming alcohol and caffeine beverages, physical activity, pregnancy, childbirth, forceps and vacuum-assisted births, episiotomy, abdominal resection for colorectal cancer, and hormone replacement therapy. For the purposes of this review, incontinence populations will be stratified into the following; the elderly, urology patients, postoperative patients, rehabilitation settings, and neurogenic bladder populations. Urinary incontinence is defined as any involuntary leakage of urine. Incontinence can be classified into diagnostic clinical types that are useful in planning evaluation and treatment. The major types of incontinence are stress (physical exertion), urge (overactive bladder), mixed (combined urge and stress urinary incontinence), reflex (neurological impairment of the central nervous system), overflow (leakage due to full bladder), continuous (urinary tract abnormalities), congenital incontinence, and transient incontinence (temporary incontinence). Postvoid residual (PVR) urine volume, which is the amount of urine in the bladder immediately after urination, represents an important component in continence assessment and bladder management to provide quantitative feedback to the patient and continence care team regarding the effectiveness of the voiding technique. Although there is no standardized definition of normal PVR urine volume, measurements greater than 100 mL to 150 mL are considered an indication for urinary

  11. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    International Nuclear Information System (INIS)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G

    2015-01-01

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits

  12. SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

    Energy Technology Data Exchange (ETDEWEB)

    LaFrance, M; Marsh, S; Hicks, R; O’Donnell-Moran, G [Baystate Health Systems, Inc., Springfield, MA (United States)

    2015-06-15

    Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

  13. The Growth of Academic Radiation Oncology: A Survey of Endowed Professorships in Radiation Oncology

    International Nuclear Information System (INIS)

    Wasserman, Todd H.; Smith, Steven M.; Powell, Simon N.

    2009-01-01

    Purpose: The academic health of a medical specialty can be gauged by the level of university support through endowed professorships. Methods and Materials: We conducted a survey of the 86 academic programs in radiation oncology to determine the current status of endowed chairs in this discipline. Results: Over the past decade, the number of endowed chairs has more than doubled, and it has almost tripled over the past 13 years. The number of programs with at least one chair has increased from 31% to 65%. Conclusions: Coupled with other indicators of academic growth, such as the proportion of graduating residents seeking academic positions, there has been clear and sustained growth in academic radiation oncology.

  14. Portable laser synthesizer for high-speed multi-dimensional spectroscopy

    Science.gov (United States)

    Demos, Stavros G [Livermore, CA; Shverdin, Miroslav Y [Sunnyvale, CA; Shirk, Michael D [Brentwood, CA

    2012-05-29

    Portable, field-deployable laser synthesizer devices designed for multi-dimensional spectrometry and time-resolved and/or hyperspectral imaging include a coherent light source which simultaneously produces a very broad, energetic, discrete spectrum spanning through or within the ultraviolet, visible, and near infrared wavelengths. The light output is spectrally resolved and each wavelength is delayed with respect to each other. A probe enables light delivery to a target. For multidimensional spectroscopy applications, the probe can collect the resulting emission and deliver this radiation to a time gated spectrometer for temporal and spectral analysis.

  15. Preliminary study on the measurement of background radiation dose at Antarctica during 32nd expedition

    International Nuclear Information System (INIS)

    Bakshi, A.K.; Pal, Rupali; Chougaonkar, M.P.; Dhar, Ajay

    2013-01-01

    A significant proportion (10%) of the natural background radiation is of cosmic origin. Cosmic ray consists of gamma, protons, electrons, pions, muons, neutrons and low Z nuclei. Due to the geomagnetic effect, cosmic radiation levels at poles are higher. As a consequence, personnel working in Antarctica (or Arctic) are subjected to high level of cosmic radiation. The present study gives the details of the estimation of background radiation (neutrons, gamma and electrons) dose rate around the Indian station at Antarctica named 'Bharati' measured during 32 nd Indian scientific expedition to Antarctica (32 nd INSEA). The measurement was carried out by passive dosimeters such as TLDs and CR-39 and active dosimeter such as RadEye G portable gamma survey meter. Gamma and electron components were measured using TLDs and survey meter, whereas CR-39 SSNTDs and neutron sensitive TLDs were used for neutron measurements. These detectors were deployed at few selected locations around Bharati station for about 2½ months during summer expedition. The neutron detectors used in the study were pre-calibrated with 241 Am-Be fast/thermal neutron source. The fast neutron dose rate measured based on CR-39 detector was found to about 140-420 nSv/h. The gamma dose rate evaluated by TLDs/survey meter are in the range of 290-400 nSv/h. (author)

  16. The results of complex radiation-hygienic survey of the reference settlements in Mogilev region

    International Nuclear Information System (INIS)

    Ageeva, T.N.; Chegerova, T.I.; Shchur, A.V.; Shapsheeva, T.P.; Lipnitskij, L.V.

    2011-01-01

    The results of complex radiation-hygienic survey of the reference settlements located on the radioactively contaminated territory have been presents in the article. The four-year dynamics of the internal exposure doses of the reference settlements' inhabitants and their relationship with the 137 Cs content in foods consumed by the population have been shown. It was ascertained that there are still some isolated individuals with high doses of internal radiation among the surveyed population, which have the significant influence on the average annual radiation dose for the inhabitants and dose of its critical group. The external exposure individual doses of the inhabitants and the results of measuring of the gamma radiation dose rate in place of the settlements have been analyzed. It have been expressed the opinion about need entering adjustment in the measuring techniques of external doses. (authors)

  17. Lead exposure in radiator repair workers: a survey of Washington State radiator repair shops and review of occupational lead exposure registry data.

    Science.gov (United States)

    Whittaker, Stephen G

    2003-07-01

    Radiator repair workers in Washington State have the greatest number of very elevated (> or =60 microg/dL) blood lead levels of any other worker population. The goals of this study were to determine the number of radiator repair workers potentially exposed to lead; estimate the extent of blood lead data underreporting to the Occupational Lead Exposure Registry; describe current safety and health practices in radiator repair shops; and determine appropriate intervention strategies to reduce exposure and increase employer and worker awareness. Lead exposure in Washington State's radiator repair workers was assessed by reviewing Registry data and conducting a statewide survey of radiator repair businesses. This study revealed that a total of 226 workers in Washington State (including owner-operators and all employees) conduct repair activities that could potentially result in excessive exposures to lead. Approximately 26% of radiator repair workers with elevated blood lead levels (> or =25 microg/dL) were determined to report to Washington State's Registry. This study also revealed a lack of awareness of lead's health effects, appropriate industrial hygiene controls, and the requirements of the Lead Standard. Survey respondents requested information on a variety of workplace health and safety issues and waste management; 80% requested a confidential, free-of-charge consultation. Combining data derived from an occupational health surveillance system and a statewide mail survey proved effective at characterizing lead exposures and directing public health intervention in Washington State.

  18. Development of a portable system to test area monitors for neutrons

    International Nuclear Information System (INIS)

    Souza, Luciane de Rezende

    2011-02-01

    The objective is to develop a portable system to test the reliability in terms of calibration of area monitors for neutrons. For the production of this system, thickness and location of the source within the system were simulated using the code of radiation transport MCNP5. The thicknesses were set for a 241 Am-Be source with an activity of 395 mCi, which will be in a polyethylene cylinder which will provide a ambient dose equivalent rate chosen through the points of calibration settings' used by the Laboratory of Neutrons (IRD / CNEN). The results obtained in this study show the feasibility of mounting the portable system as a tool to test the area monitors for neutrons, which will provide the user of neutron area monitors to check the instrument's response in the same field of operation, thus avoiding the use of an inadequate equipment. (author)

  19. The use and risk of portable electronic devices while cycling among different age groups

    NARCIS (Netherlands)

    Goldenbeld, C.; Houtenbos, M.; Ehlers, E.; De Waard, D.

    Introduction: In the Netherlands, a survey was set up to monitor the extent of the use of portable, electronic devices while cycling amongst different age groups of cyclists and to estimate the possible consequences for safety. Method: The main research questions concerned age differences in the

  20. A questionnaire survey about public's image of radiation after the Fukushima Dacha Nuclear Power Plant accident

    International Nuclear Information System (INIS)

    Okazaki, Ryuji; Ootsuyama, Akira; Kubo, Tatsuhiko; Abe, Toshiaki

    2012-01-01

    A questionnaire survey about the public's image of radiation was performed after the Fukushima Daiichi nuclear power plant (FDNPP) accident. The survey was taken by general citizens (200 and 1,640 in Fukushima and 52 outside of Fukushima) and doctors (63 in Fukushima and 1,942 outside of Fukushima (53 in Oita, 44 in Sagamihara and 1,845 in Kitakyushu) in and outside of Fukushima and second year medical students in the University of Occupational and Environmental Health, Japan. The questionnaire surveys were performed during lectures about radiation. The response rates were 86% for the general citizens in Fukushima, 91% for the general citizens outside of Fukushima, 86% for doctors in Fukushima, 85% and 86% for doctors in Sagamihara and Oita, respectively. The questionnaire surveys were sent to clinics and hospitals in Fukushima where the general citizens answered with a response rate of 50%. When the questionnaire surveys were sent to clinics and hospitals in Kitakyushu, doctors answered, with a response rate of 17%. The percentages of anxiety about future radiation effects after the FDNPP accident were the highest among the general citizens (71.6% in Fukushima and 40.4% outside of Fukushima), in the middle among the doctors (30.2% in Fukushima and 26.2% outside of Fukushima) and the lowest among the medical students (12.2%). The doctors in Fukushima and the medical students were anxious about food and soil pollution. The general citizens and the detectors outside of Fukushima were anxious about health problems and food and soil pollution. We concluded that a high level of education about radiation decreased the anxiety about the radiation effects. It is important to spread knowledge about radiation. (author)

  1. Knowledge in Radiation Protection: a Survey of Professionals in Medical Imaging, Radiation Therapy and Nuclear Medicine Units in Yaounde

    International Nuclear Information System (INIS)

    Ongolo-Zogo, P.; Nguehouo, M.B.; Yomi, J.; Nko'o Amven, S.

    2013-01-01

    Medical use of ionizing radiation is now the most common radiation source of the population at the global level. The knowledge and practices of health professionals working with X-rays determine the level and quality of implementation of internationally and nationally recommended measures for radiation protection of patients and workers. The level of implementation and enforcement of international recommendations in African countries is an issue of concern due to weak laws and regulations and regulatory bodies. We report the results of a cross-sectional survey of health professionals working with ionizing radiation in Yaounde, the capital city of Cameroon. More than 50% of these professionals have a moderate level of knowledge of the norms and principles of radiation protection and more than 80% have never attended a continuing professional development workshop on radiation protection. (authors)

  2. Radiation safety considerations and compliance within equine veterinary clinics: Results of an Australian survey

    International Nuclear Information System (INIS)

    Surjan, Y.; Ostwald, P.; Milross, C.; Warren-Forward, H.

    2015-01-01

    Objective: To examine current knowledge and the level of compliance of radiation safety principles in equine veterinary clinics within Australia. Method: Surveys were sent to equine veterinary surgeons working in Australia. The survey was delivered both online and in hardcopy format; it comprised 49 questions, 15 of these directly related to radiation safety. The participants were asked about their current and previous use of radiation-producing equipment. Information regarding their level of knowledge and application of radiation safety principles and practice standards was collected and analysed. Results: The use of radiation-producing equipment was evident in 94% of responding clinics (a combination of X-ray, CT and/or Nuclear Medicine Cameras). Of those with radiation-producing equipment, 94% indicated that they hold a radiation licence, 78% had never completed a certified radiation safety course and 19% of participants did not use a personal radiation monitor. In 14% of cases, radiation safety manuals or protocols were not available within clinics. Conclusions: The study has shown that knowledge and application of guidelines as provided by the Code of Practice for Radiation Protection in Veterinary Medicine (2009) is poorly adhered to. The importance of compliance with regulatory requirements is pivotal in minimising occupational exposure to ionising radiation in veterinary medicine, thus there is a need for increased education and training in the area. - Highlights: • Application of the Code of Practice for Veterinary Medicine is poorly adhered to. • Majority of veterinary clinics had not completed certified radiation safety course. • One-fifth of participants did not use personal radiation monitoring. • Increased education and training in area of radiation safety and protection required to generate compliance in clinics

  3. A Trusted Portable Computing Device

    Science.gov (United States)

    Ming-wei, Fang; Jun-jun, Wu; Peng-fei, Yu; Xin-fang, Zhang

    A trusted portable computing device and its security mechanism were presented to solve the security issues, such as the attack of virus and Trojan horse, the lost and stolen of storage device, in mobile office. It used smart card to build a trusted portable security base, virtualization to create a secure virtual execution environment, two-factor authentication mechanism to identify legitimate users, and dynamic encryption to protect data privacy. The security environment described in this paper is characteristic of portability, security and reliability. It can meet the security requirement of mobile office.

  4. Portable gamma-ray spectrometers and spectrometry systems

    International Nuclear Information System (INIS)

    Shebell, P.

    1999-01-01

    The current state-of-the-art in portable gamma-ray spectrometers and portable spectrometry systems is discussed. A comparison of detector performance and features of commercially available systems are summarised. Finally, several applications of portable systems are described. (author)

  5. The use and risk of portable electronic devices while cycling among different age groups.

    NARCIS (Netherlands)

    Goldenbeld, C. Houtenbos, M. Ehlers, E. & Waard, D. de

    2012-01-01

    In The Netherlands, a survey was set up to monitor the extent of the use of portable, electronic devices while cycling amongst different age groups of cyclists and to estimate the possible consequences for safety. The main research questions concerned age differences in the self-reported use of

  6. Possible extensions of XIA's digital spectrometer technology to portable and remote monitoring instrumentation

    International Nuclear Information System (INIS)

    Warburton, W.K.; Darknell, D.A.; Hubbard-Nelson, B.

    1998-01-01

    The XIA DXP-4C is a 4 channel, CAMAC based, X-ray spectrometer which digitally processes directly digitized preamplifier signals. The DXP-4C was designed for instrumenting multi-detector arrays for synchrotron radiation applications, and optimized for very high count rates at a low cost per detector channel. This produced a very compact and low power (3.4 W/channel) instrument for its count rate and MCA capabilities, which thus provides a strong basis for portable applications. Because all functions are digitally controlled, it can be readily adapted to various user interfaces, including remote access interfaces. Here the authors describe the design and examine approaches to lowering its power to 50 mW/channel. They then consider the issues in applying it to three typical portable or remote spectrometry applications

  7. Portable, transportable or installed X or gamma radiation ratemeters for environmental monitoring. Part 1: Ratemeters (International Electrotechnical Commission Standard Publication 61017-1:1991)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2000-01-01

    This standard is applicable to portable, transportable or installed assemblies intended to measure environmental air kerma rates from 30 nGy h -1 to 10 μGy h -1 (3 μrad h -1 to 1 mrad h -1 ) due to X or gamma radiation of energy between at least 50 keV and 1.5MeV * . If the assembly is to be used to measure air measure air kerma rates in the area surrounding a nuclear reactor producing 6 MeV radiation it will be necessary to determine the response at this energy. For the purpose of radiation protection these assemblies comprise at least: - a detection sub-assembly (e.g. ionization chamber, GM counter tube, scintillation detector, etc.); - a measuring sub-assembly including a display device, which may be connected together either rigidly or by means of a flexible cable or incorporated into a single assembly. The installed assembly may also comprise a continuous recorder (e.g. chart or magnetic cassette recorder or telemetry equipment). The requirements of this standard are also applicable to assemblies that use integration of ionization current, count-rate, etc. to enable a mean air kerma rate to be indicated or determined. For the assemblies described above, this standard specifies general characteristics, general test procedures, radiation characteristics, electrical, mechanical, safety and environmental characteristics as well the identification certificate. Assemblies that indicate air kerma from integration of the detector's signal will be dealt with in the future IEC Publication 1017-2. This standard does not apply to thermoluminescence dosimetry systems or other passive integrating devices. This standard does not provide for the measurement of beta radiation

  8. Proceedings of the workshop on radiation survey instruments and calibrations

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Vallario, E.J.; Murphy, B.L.

    1985-11-01

    The workshop was held to discuss two topics: first, a performance standard for radiation survey instruments and the potential for a testing program based on that standard; and second, a system of secondary standards laboratories to provide instrument calibrations and related services. Separate abstracts have been prepared for the individual presentations

  9. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  10. Portable nucleic acid thermocyclers.

    Science.gov (United States)

    Almassian, David R; Cockrell, Lisa M; Nelson, William M

    2013-11-21

    A nucleic acid thermal cycler is considered to be portable if it is under ten pounds, easily carried by one individual, and battery powered. Nucleic acid amplification includes both polymerase chain reaction (e.g. PCR, RT-PCR) and isothermal amplification (e.g. RPA, HDA, LAMP, NASBA, RCA, ICAN, SMART, SDA). There are valuable applications for portable nucleic acid thermocyclers in fields that include clinical diagnostics, biothreat detection, and veterinary testing. A system that is portable allows for the distributed detection of targets at the point of care and a reduction of the time from sample to answer. The designer of a portable nucleic acid thermocycler must carefully consider both thermal control and the detection of amplification. In addition to thermal control and detection, the designer may consider the integration of a sample preparation subsystem with the nucleic acid thermocycler. There are a variety of technologies that can achieve accurate thermal control and the detection of nucleic acid amplification. Important evaluation criteria for each technology include maturity, power requirements, cost, sensitivity, speed, and manufacturability. Ultimately the needs of a particular market will lead to user requirements that drive the decision between available technologies.

  11. Survey of radiation doses received by atomic-bomb survivors residing in the United States

    International Nuclear Information System (INIS)

    Kerr, G.D.; Yamada, H.; Marks, S.

    1976-01-01

    A survey has been completed of 300 of an estimated 500 to 750 survivors of the atomic bombings in Hiroshima and Nagasaki who reside in the United States. Distributions with respect to age, sex, citizenship status, distance from the hypocenter at the time of bombing, and dose from immediate weapon radiation have been tabulated from the results and are presented for this group of 300 survivors. Also presented are survey results concerning exposures to residual radiation from fallout and neutron-induced radioactivity in the areas adjacent to the hypocenter

  12. 46 CFR 78.47-70 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Portable magazine chests. 78.47-70 Section 78.47-70... Fire and Emergency Equipment, Etc. § 78.47-70 Portable magazine chests. (a) Portable magazine chest shall be marked in letters of at least 3 inches high “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND...

  13. 46 CFR 97.37-47 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 97.37-47 Section 97.37-47... OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP...

  14. 46 CFR 196.37-47 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 196.37-47 Section 196.37-47... Markings for Fire and Emergency Equipment, etc. § 196.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: PORTABLE MAGAZINE CHEST — FLAMMABLE — KEEP...

  15. Radiation protection in equine radiography

    International Nuclear Information System (INIS)

    Wood, A.K.W.; Reynolds, K.M.; Leith, I.S.; Burns, P.A.

    1974-01-01

    During radiography of the carpus of horses calcium fluoride thermoluminescent dosemeters were used to measure the radiation exposure to the hand of an assistant positioning the x-ray film. Three portable x-ray machines and a mobile machine were used during the recordings. The effects of x-ray machine, radiographic technique, and lead rubber gloves upon radiation exposure to the hand were investigated. The size of the primary beam of the x-ray machine was found to be the major factor in determining the dose of radiation received by the hand. The highest radiation exposures were recorded when using two portable machines which were fitted with beam limiting devices that permitted only one primary beam size. The lowest exposures were measured when radiographs were taken with the mobile machine that was fitted with a light beam diaphragm. The control of primary beam size with a light beam diaphragm was found to be the most effective method of reducing radiation dosage to the hand. It is strongly recommended that for equine radiography a light beam diaphragm be fitted to and used on all x-ray machines, and a cassette holder be used to keep the hands out of the primary beam. (author)

  16. 29 CFR 1915.132 - Portable electric tools.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Portable electric tools. 1915.132 Section 1915.132 Labor... § 1915.132 Portable electric tools. The provisions of this section shall apply to ship repairing... frames of portable electric tools and appliances, except double insulated tools approved by Underwriters...

  17. 21 CFR 868.5440 - Portable oxygen generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable oxygen generator. 868.5440 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5440 Portable oxygen generator. (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory...

  18. Development of Data Storage System for Portable Multichannel Analyzer using S D Card

    International Nuclear Information System (INIS)

    Suksompong, Tanate; Ngernvijit, Narippawaj; Sudprasert, Wanwisa

    2009-07-01

    Full text: The development of data storage system for portable multichannel analyzer (MCA) focused on the application of SD card as a storage device instead of the older devices that could not easily extend their capacity. The entire work consisted of two parts: the first part was the study for pulse detection by designing the input pulse detecting circuit. The second part dealed with the accuracy testing of data storage system for portable MCA, consisting of the design of connecting circuit between micro controller and SD card, the transfer of input pulse data into SD card and the ability of data storage system for radiation detection. It was found that the input pulse detecting circuit could detect the input pulse with the maximum voltage, then the signal was transferred to micro controller for data processing. The micro controller could connect to SD card via SPI MODE. The portable MCA could perfectly verify the input signal ranging from 0.2 to 5.0 volts. The SD card could store the data as . xls file which could easily be accessed by the compatible software such as Microsoft Excel

  19. Understanding portable generators

    Energy Technology Data Exchange (ETDEWEB)

    Hills, A.; Hawkins, B. [Guelph Univ., ON (Canada); Clarke, S. [Ontario Ministry of Agriculture, Food and Rural Affairs, Toronto, ON (Canada)

    2000-06-01

    This factsheet is intended to help consumers select a small portable generator for emergency electrical needs. Interest in standby generators has been heightened ever since the prolonged power outage in Eastern Ontario and Southwestern Quebec during the 1998 ice storm and the concern over Y2K related outages. Farmers, in particular, have been reassessing their need for emergency electrical power supply. This document presents some of the factors that should be considered when purchasing and operating a portable generator in the 3 to 12 kW size. It provides a detailed review of power quality and describes the use of tractor-driven power-take-off generators of 15 kW and larger. Several manufacturers make portable generators in many sizes with a whole range of features. This document includes a table depicting generator Feature/Benefit analysis to help consumers understand the differences between features and benefits. A second table provides a check list for generator feature/benefits. Specific details for the operations of various generators are available from manufacturers, distributors and electrical contractors. 2 tabs., 1 fig.

  20. The determination of the penetrating radiation dose at Hanford

    International Nuclear Information System (INIS)

    Rathbun, L.A.

    1989-09-01

    Most of the thermoluminescent dosimeters (TLDs) and other devices that have been used to measure environmental radiation on the Hanford Site have measured natural background levels of radiation. Measurements of offsite environmental radiation near the boundary of the Hanford Site have often indicated higher doses than onsite measurements have. However, the converse has been found when radiation measurements from the cities and communities of southeastern Washington were compared with onsite measurements. The historical trends described for environmental TLD data have been better defined in this study by compiling the TLD data for selected locations over a 6-year period (1983 to 1988). The ongoing Hanford Environmental Surveillance Program also provides radionuclide concentrations in soil based on samples collected by technicians at Pacific Northwest Laboratory (PNL) and sent to a commercial laboratory for analyses. As part of the study described in this report, a portable gamma spectroscopy system was used in the field to identify concentrations of gamma-emitting radionuclides in the soil at various locations on the Hanford Site and in the surrounding area. This work began in 1986. Supplemental radiation measurements were made with a microprocessor-based survey meter and large NaI detector. 20 refs., 4 figs., 3 tabs

  1. New portability for in situ gamma-ray spectrometry from commercially available equipment

    International Nuclear Information System (INIS)

    Stanford, N.; Laurenzo, E.L.; McCurdy, D.E.

    1984-01-01

    In situ gamma-ray spectrometry has been employed by the staff of the Yankee Atomic Environmental Laboratory on a routine basis for more than five years. The original in situ gamma-ray spectrometry methodology was adopted from the techniques developed at the DOE Environmental Measurements Laboratory (Beck, DeCampo, and Gogolak 1972). The system consisted of a 110 cm 3 Ge(Li) detector in the vertical configuration in conjunction with typical laboratory nuclear instrumentation, as well as a medium-sized desktop computer, printer and disk drive. The equipment was transported in a small van having a shock-mounted cabinet and gasoline generator as an electrical power source. Recent availability of miniaturized spectrometry systems and powerful portable computers has enabled the upgrading of the 1977 vintage equipment to a system which is truly portable, light weight, compact and more reliable. The system to be described utilizes a portable intrinsic germanium detector, a small, 4096 channel pulse height analyzer (MCA) with anscillary components and a 24K, Hewlett Packard HP-75 computer with a small tape drive. When the equipment is used in the field, the system has enough capability to acquire and store a full 4096 channel gamma-ray spectrum and calculate the soil concentrations (pCi/g) and/or external radiation exposure rates for the commonly found naturally occurring, long-lived atmospheric nuclear weapons testing and nuclear power plant radionuclides. Subsequent data transfer to a larger desktop computer via available interfacing at the laboratory enables a full peak search and a more extensive evaluation of the data in order to calculate the soil concentrations and/or external radiation exposure rates for a selected 25 radionuclides. Experiences from the first season of operation are discussed

  2. Searching for Orphan radiation sources

    International Nuclear Information System (INIS)

    Bystrov, Evgenij; Antonau, Uladzimir; Gurinovich, Uladzimir; Kazhamiakin, Valery; Petrov, Vitaly; Shulhovich, Heorhi; Tischenko, Siarhei

    2008-01-01

    Full text: The problem of orphan sources cannot be left unaddressed due high probability of accidental exposure and use of sources for terrorism. Search of objects of this kind is complex particularly when search territory is large. This requires devices capable of detecting sources, identifying their radionuclide composition, and correlating scan results to geographical coordinates and displaying results on a map. Spectral radiation scanner AT6101C can fulfill the objective of search for gamma and neutron radiation sources, radionuclide composition identification, correlation results to geographical coordinates and displaying results on a map. The scanner consists of gamma radiation scintillation detection unit based on NaI(Tl) crystal, neutron detection unit based on two He 3 counters, GPS receiver and portable ruggedized computer. Built-in and application software automates entire scan process, saving all results to memory for further analysis with visual representation of results as spectral information diagrams, count rate profile and gamma radiation dose rates on a geographical map. The scanner informs operator with voice messages on detection of radiation sources, identification result and other events. Scanner detection units and accessories are packed in a backpack. Weighing 7 kg, the scanner is human portable and can be used for scan inside cars. The scanner can also be used for radiation mapping and inspections. (author)

  3. Design and development of a Compact Aerial Radiation Monitoring System (CARMS)

    International Nuclear Information System (INIS)

    Raman, N.; Chaudhury, Probal; Padmanabhan, N.; Pradeepkumar, K.S.; Sharma, D.N.

    2005-01-01

    Operation of nuclear facilities, increasing usage of radioisotopes in industrial, scientific and medical applications and transport of nuclear and radioactive materials may have impact on the surrounding environment. There is thus a need to periodically monitor the environmental radiation background all over the country and particularly around the nuclear facilities for assessing any possible impact on the environment. Preparedness required for response to emergencies caused due to radiological/nuclear incidents/ accidents or due to radiological/nuclear terrorism also demands state of the art systems and methodology for quick assessment of radiological impact over large affected areas. In order to meet these requirements, a Compact Aerial Radiation Monitoring System (CARMS) has been designed and developed. This system is battery operated, portable and rugged for mobile radiation monitoring and can be placed in aerial platforms like helicopters or Unmanned Aerial Vehicles (UAVs) for unattended operation. CARMS uses energy compensated multiple GM detectors for enhancing sensitivity and is attached with commercially available Global Positioning System (GPS) for online acquisition of positional coordinates with time. The AT89LV52 microcontroller used in the system tags the dose rate data with time and positional information and stores contiguously in a serial data memory for radiological mapping of the area surveyed using any mobile platform such as aircraft/train/boat/road vehicle. The system consumes ∼150 mA including the GPS at 12 V DC enabling ∼50 hours of continuous monitoring with a 7 Ah battery source. The system has been used in aerial, rail and road based environmental radiation surveys carried out at various places of the country. With PC support, the system can map the radiological status online onto the map of the area being surveyed to help decision-making on countermeasures during the survey. (author)

  4. 30 CFR 47.44 - Temporary, portable containers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary, portable containers. 47.44 Section... TRAINING HAZARD COMMUNICATION (HazCom) Container Labels and Other Forms of Warning § 47.44 Temporary, portable containers. (a) The operator does not have to label a temporary, portable container if he or she...

  5. 48 CFR 1852.237-71 - Pension portability.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Pension portability. 1852... 1852.237-71 Pension portability. As prescribed at 1837.110-70(b), insert the following clause: Pension Portability (JAN 1997) (a) In order for pension costs attributable to employees assigned to this contract to...

  6. Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign

    International Nuclear Information System (INIS)

    Christopher Hodge, Raymond Keegan

    2007-01-01

    Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to submit their equipment for independent operationally relevant testing to subsequently improve their detector performance. This paper will present the design, execution, and methodologies of the DHS Anole portable radiation detection system test campaign

  7. Fifth nationwide survey on radiation oncology of China in 2006

    International Nuclear Information System (INIS)

    Yin Weibo; Yuyun; Chen Bo; Tian Fenghua

    2007-01-01

    Objective: In order to find out the present status of Chinese Radiation Oncology, the Chinese Society of Radiation Oncology did the fifth nationwide survey on Radiation Oncology in China. Methods: Questionnaire forms had been sent through the board member of Chinese Society of Radiation Oncology to each center throughout the country. The forms, after filing, were returned for analysis. Results: On September 30th, 2006, there were 952 radiation oncology centers. They possess personnel: 5247 doctors including 2 110 residents, 1181 physicists, 6864 nurses, 4559 technicians and 1141 engineers. For equipment: There were 918 linear accelerators, 472 telecobalt units, 146 deep X-ray machine, 827 simulators, 214 CT simulators, 400 brachytherapy units, 400 treatment planning system, 796 dosimeters, 467 X-knife, 149 γ-knife (74 for head only, 75 for the head and body). Treatment: 35 503 beds (35 centers did not report the number of beds), 42 109 patients treated per day, 409 440 new patients were treated per year (no report from 45 centers). Conclusion: Radiation oncology has been developing rapidly in the last 5 years either in quantity or in quality. They are still being considered insufficient in proportion to our population. Training programs and development of QA and QC system ate needed. (authors)

  8. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O. [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1997-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  9. Car-borne survey measurements with a 3x3' NaI detector

    International Nuclear Information System (INIS)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O.

    1997-01-01

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3' NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of 137 Cs. Our results show that even standard 3x3' NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au)

  10. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E; Ugletveit, F; Floe, L; Mikkelborg, O [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1998-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  11. 'Radiation Fair' for 15 years in Osaka, Japan, and survey of the participants attitude toward radiation

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Masakazu; Asano, Takeyoshi; Hayashi, Toshio; Hosokawa, Yasushi [Research Institute for Advanced Science and Technology, Osaka Prefecture Univ., Sakai, Osaka (Japan); Kakefu, Tomohisa; Nishihara, Hideaki

    1999-09-01

    We have been successfully operating 'Radiation Fair--The relationship between daily life and radiation--' during summer vacation season in August every year for 15 years in Osaka, the largest city of western Japan. The purpose of this event is radiation education of public including school kids through efficient information transfer of radiation and radiation-related technology. Currently we set up the space of it on a floor of Kintetsu Department Store, one of the major department stores in downtown Osaka and display various irradiated products available in our daily life together with explanatory panels. We have been devising various attractions as efficient information transfer media so that even elementary-school kids understand the basic knowledge of radiation and irradiation technologies. The number of participants has increased year by year until more than 20,000 in recent years. We distributed questionnaires to the visitors for recent 3 years to inquire their status toward radiation and irradiated products as well as impression toward the displays. The survey results suggest that school education may contribute to establish the public image toward 'radiation' as well as mass media. (author)

  12. 29 CFR 1917.119 - Portable ladders.

    Science.gov (United States)

    2010-07-01

    ... Requirements for Portable Reinforced Plastic Ladders (d) Standards for job-made portable ladders. Job-made... usage. (1) Ladders made by fastening rungs or devices across a single rail are prohibited. (2) Ladders...

  13. Evaluation of uncertainties in the calibration of radiation survey meter

    International Nuclear Information System (INIS)

    Potiens, M.P.A.; Santos, G.P.

    2006-01-01

    In order to meet the requirements of ISO 17025, the quantification of the expanded uncertainties of experimental data in the calibration of survey meters must be carried out using well defined concepts, like those expressed in the 'ISO-Guide to the Expression of Uncertainty in Measurement'. The calibration procedure of gamma ray survey meters involves two values that have to get their uncertainties clearly known: measurements of the instrument under calibration and the conventional true values of a quantity. Considering the continuous improvement of the calibration methods and set-ups, it is necessary to evaluate periodically the involved uncertainties in the procedures. In this work it is shown how the measurement uncertainties of an individual calibration can be estimated and how it can be generalized to be valid for others radiation survey meters. (authors)

  14. Treatment of plutonium-bearing solutions: A brief survey of the DOE complex

    International Nuclear Information System (INIS)

    Conner, C.; Chamberlain, D.B.; Chen, L.; Vandegrift, G.F.

    1995-03-01

    With the abrupt shutdown of some DOE facilities, a significant volume of in-process material was left in place and still requires treatment for interim storage. Because the systems containing these process streams have deteriorated since shutdown, a portable system for treating the solutions may be useful. A brief survey was made of the DOE complex on the need for a portable treatment system to treat plutonium-bearing solutions. A survey was completed to determine (1) the compositions and volumes of solutions and heels present, (2) the methods that have been used to treat these solutions and heels in the past, and (3) the potential problems that exist in removing and treating these solutions. Based on the surveys and on the Defense Nuclear Facilities Safety Board Recommendation 94-1, design criteria for a portable treatment system were generated

  15. Portable nucleonics instrument design: The PortaCAT example

    International Nuclear Information System (INIS)

    Wallace, G.; Pohl, P.; Hutchinson, E.

    2000-01-01

    Portable nucleonic gauges prototypes are designed and manufactured in New Zealand for niche applications. Considerable development in hardware and software provide new opportunity in design of relatively low cost portable nucleonic gauges. In this paper are illustrated principles, and specific factors to be consider when designing portable nucleonic instrumentation, using an example called PortaCAT, which is a portable computed tomography scanner designed for imaging wooden power poles. (author)

  16. Portable Tablets in Science Museum Learning

    DEFF Research Database (Denmark)

    Gronemann, Sigurd Trolle

    2016-01-01

    Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people...... is identified. It is argued that, paradoxically, museums’ decisions to innovate by introducing new technologies, such as portable tablets, and new pedagogies to support them conflict with many young people’s traditional ideas of museums and learning. The assessment of the implications of museums’ integration...... of portable tablets indicates that in making pedagogical transformations to accommodate new technologies, museums risk opposing didactic intention if pedagogies do not sufficiently attend to young learners’ systemic expectations to learning and to their expectations to the digital experience influenced...

  17. Gaps in Radiation Therapy Awareness: Results From an Educational Multi-institutional Survey of US Internal Medicine Residents.

    Science.gov (United States)

    Shaverdian, Narek; Yoo, Sun Mi; Cook, Ryan; Chang, Eric M; Jiang, Naomi; Yuan, Ye; Sandler, Kiri; Steinberg, Michael; Lee, Percy

    2017-08-01

    Internists and primary care providers play a growing role in cancer care. We therefore evaluated the awareness of radiation therapy in general and specifically the clinical utility of stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) among current US internal medicine residents. A web-based institutional review board-approved multi-institutional survey was distributed to US internal medicine residency programs. The survey evaluated trainee demographic characteristics, baseline radiation oncology awareness, knowledge of the role of SBRT for early-stage NSCLC, and whether the survey successfully improved awareness. Thirty US internal medicine programs participated, with an overall participant response rate of 46% (1177 of 2551). Of the trainees, 93% (n=1076) reported no radiation oncology education in their residency, 39% (n=452) reported confidence in knowing when to consult radiation oncology in an oncologic emergency, and 26% (n=293) reported confidence in knowing when to consult radiation oncology in the setting of a newly diagnosed cancer. Of the participants, 76% (n=850) correctly identified that surgical resection is the standard treatment in operable early-stage NSCLC, but only 50% (n=559) of participants would recommend SBRT to a medically inoperable patient, followed by 31% of participants (n=347) who were unsure of the most appropriate treatment, and 10% (n=117) who recommended waiting to offer palliative therapy. Ninety percent of participants (n=1029) agreed that they would benefit from further training on when to consult radiation oncology. Overall, 96% (n=1072) indicated that the survey increased their knowledge and awareness of the role of SBRT. The majority of participating trainees received no education in radiation oncology in their residency, reported a lack of confidence regarding when to consult radiation oncology, and overwhelmingly agreed that they would benefit from further training. These findings

  18. Hydrogen in portable devices

    Energy Technology Data Exchange (ETDEWEB)

    Garche, J. [ZSW - Electrochemical Energy storage and energy Conversion Division, Baden Wuerttemberg (Germany); Stimmer, U. [Technische Universitaet, Muenchen (Germany); Friedrich, A.K. [ZAE Bayern (Germany); Fiedenhans' l, R. [Risoe National Lab., Materials Res. Dept., Roskilde (Denmark)

    2004-10-01

    Fuel cells were originally intended for use in power plants and vehicles. More recently, developers realised the possibility for building much smaller units and for lower prices per kilowatt than their larger relatives. This has led to a strong interest in developing small fuel cells. Small fuel cells could replace batteries in portable electronic equipment and internal combustion engines in portable generators. The upper limit for portable generators is about 5kW, mainly because of the weight of the fuel cell. The main applications for low-power fuel cells are mobile phones, personal digital assistants, laptop and notebook computers, cameras, medical equipment, military applications and other portable electronic devices. In comparison to batteries, fuel cells can supply much more power per unit volume or weight, though they have lower output voltages and are slower to respond to transients. Fuel cell types that are suitable for portable applications include: proton exchange membrane fuel cells (PEMFCs) using pure hydrogen, PEMFCs using hydrogen-rich gases from hydrocarbon or alcohol reforming, direct methanol fuel cells and, high-temperature fuel cells such as solid oxide fuel cells (SOFCs) and molten carbonate fuel cells (MCFCs) using hydrocarbons directly. Fuel cells for portable devices is becoming a niche, high-value market area which has good opportunities for a fast introduction of fuel cell technology and for the first consumer products in the electronic market can be expected within the coming year and is believed to grow rapidly thereafter. Danish industry is involved in the development of SOFC, PEMFC and DMFC fuel cells and the industry has in particular a strong position in system components and complete systems. An important area for Danish industry is system integration, where fuel cells and hydrogen technologies are implemented in electrical powered products. This is an area that is particular suited for small and medium sized enterprises and for

  19. Hydrogen in portable devices

    International Nuclear Information System (INIS)

    Garche, J.; Stimmer, U.; Friedrich, A.K.; Fiedenhans'l, R.

    2004-01-01

    Fuel cells were originally intended for use in power plants and vehicles. More recently, developers realised the possibility for building much smaller units and for lower prices per kilowatt than their larger relatives. This has led to a strong interest in developing small fuel cells. Small fuel cells could replace batteries in portable electronic equipment and internal combustion engines in portable generators. The upper limit for portable generators is about 5kW, mainly because of the weight of the fuel cell. The main applications for low-power fuel cells are mobile phones, personal digital assistants, laptop and notebook computers, cameras, medical equipment, military applications and other portable electronic devices. In comparison to batteries, fuel cells can supply much more power per unit volume or weight, though they have lower output voltages and are slower to respond to transients. Fuel cell types that are suitable for portable applications include: proton exchange membrane fuel cells (PEMFCs) using pure hydrogen, PEMFCs using hydrogen-rich gases from hydrocarbon or alcohol reforming, direct methanol fuel cells and, high-temperature fuel cells such as solid oxide fuel cells (SOFCs) and molten carbonate fuel cells (MCFCs) using hydrocarbons directly. Fuel cells for portable devices is becoming a niche, high-value market area which has good opportunities for a fast introduction of fuel cell technology and for the first consumer products in the electronic market can be expected within the coming year and is believed to grow rapidly thereafter. Danish industry is involved in the development of SOFC, PEMFC and DMFC fuel cells and the industry has in particular a strong position in system components and complete systems. An important area for Danish industry is system integration, where fuel cells and hydrogen technologies are implemented in electrical powered products. This is an area that is particular suited for small and medium sized enterprises and for

  20. A positioning and data logging system for surface geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1988-01-01

    The Ultrasonic Ranging and Data System (USRADS) developed at ORNL is being adapted to work with two commercially available geophysical instruments: a magnetometer and an EM31 terrain conductivity meter. Geophysical surveys have proven an important preliminary step in investigating hazardous waste sites. Magnetometers and terrain conductivity meters are used to locate buried drums, trenches, conductive contaminant plumes and map regional changes in geology. About half the field time of a typical geophysical investigation is spent surveying the position of the grid points at which the measurements will be made. Additional time is lost and errors may be made recording instrument values in field notebooks and transcribing the data to a computer. Developed for gamma radiation surveys, the USRAD system keeps track of the surveyor's position automatically by triangulating on an ultrasonic transmitter carried in a backpack. The backpack also contains a radio transmitter that sends the instrument's reading coincident with the ultrasonic pulse. The surveyor's position and the instrument's reading are recorded by a portable computer which can plot the data to check the survey's progress. Electronic files are stored in a form compatible with AutoCAD to speed report writing. 7 refs., 3 figs

  1. The use of roentgen diagnostics in chiropractor activities. Project based survey according to new regulations regarding radiation protection and use of radiation

    International Nuclear Information System (INIS)

    Raaum, Aud; Widmark, Anders

    2005-12-01

    An audit has been performed in 17 chiropractic enterprises according to new radiation protection legislation. Before the audits a survey of the use of diagnostic imaging in Norwegian chiropractic enterprises was carried out. This report summarizes the results of the survey and the findings at the audits. (Author)

  2. 49 CFR 172.326 - Portable tanks.

    Science.gov (United States)

    2010-10-01

    ... petroleum gas (LPG) that is unodorized as authorized in § 173.315(b)(1) unless it is legibly marked NON... the portable tank are not visible. (d) NON-ODORIZED marking on portable tanks containing LPG. After...

  3. A survey of radiation doses received by atomic-bomb survivors residing in the U.S

    International Nuclear Information System (INIS)

    Kerr, G.D.; Yamada, H.; Marks, S.

    1976-01-01

    A survey has been completed of 300 of an estimated 500 to 750 survivors of the atomic bombings in Hiroshima and Nagasaki who reside in the U.S. Distributions with respect to age, sex, citizenship status, distance from the hypocenter at the time of bombing, and dose from immediate weapon radiation have been tabulated from the results and are presented for this group of 300 survivors. Also presented are survey results concerning exposures to residual radiation from fallout and neutral-induced radioactivity in the areas adjacent to the hypocenter. (author)

  4. Calibration for radiation protection survey meter SSM1

    International Nuclear Information System (INIS)

    Jin Hua.

    1992-03-01

    The calibration functions for the Radiation Protection Survey Meter SSM1 built-in Geiger Mueller measuring tubes of the type ZP 1201 (low dose rate tube) and ZP 1313 (high dose rate tube) are given in the present study. Six dose rate points are proposed as the calibration points of covering the range from 500 nSv/h up to 5 Sv/h. The difference between the true dose rate and the values calculated with the method in this paper for No. 382 SSM1 is less than ±2%. (author)

  5. Radiation and contamination survey of the Terengganu offshore facilities

    International Nuclear Information System (INIS)

    Amran Abd Majid; Sukiman Sarmani

    1995-01-01

    It is well known that low specific activity of technologically enhanced naturally occurring radioactive materials (LSA TENORM) such as U-238 and Th-232 and their daughter products have been associated with oil and gas fields. For the period of October 1988 and August 1989 UKM personels were involved in conducting the radiation and contamination survey at several offshore platforms in Terengganu. The results showed that the maximum external and internal radiation levels was 0. 45 μSv/hr whereas the maximum surface contamination level was 0. 124 Bq cm sup -2. These results indicate that the levels were below the level prescribed by the Malaysian Atomic Energy Licensing Board. However, several measures still need to be considered for the safety of the workers and will be discussed in this paper. (author)

  6. Inspection surveys of x-ray inspection systems: results of five years and implications on future management of radiation risks

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    1999-01-01

    Until the mid-1980s, federal inspectors performed radiation surveys annually on individual x-ray inspection systems which were operated for security screening purposes in federal facilities nationwide, and problems identified were corrected. The surveys were undertaken because of perceived high radiation risks and a need to ensure worker and public external exposures were minimized. The x-ray inspection systems are federally regulated under the Radiation Emitting Devices (RED) Act and, initially they were assessed by model type against the design, construction and performance criteria specified in the applicable RED regulations (Schedule II, Part IV) and were found compliant. A subsequent study not only demonstrated a much lower radiation risk attributed to a combination of technological advances in x-ray system design with narrow primary beams, high efficiency detectors and image processing capability, but also stressed the need for proper equipment maintenance and continued education of operators and maintenance personnel. Survey frequency was thus reduced to once every 2-3 years in accordance with a 1993 federal operational standard (Safety Code 29). The radiation protection principles in Safety Code 29 are similar to those of the 1996 International Atomic Energy Agency (IAEA) Basic Safety Standards for the protection against ionizing radiation and the safety of radiation sources. The purpose of this study was to assess inspection-survey data from 1993 through 1997 to elicit guidance toward the future management of radiation risks associated with the operation of such x-ray systems. (author)

  7. Radiation oncology training in Poland: results of a national survey (2007)

    International Nuclear Information System (INIS)

    Niemiec, M.; Kepka, L.; Lindner, B.; Bujko, K.; Lindner, B.; Maciejewski, B.

    2008-01-01

    The aim of this survey was to evaluate the quality of training in radiation oncology in Poland in relation to the ESTRO recommendations, and to learn motivations, level of satisfaction, complaints, suggestions and career plans of radiation oncologists.The detailed questionnaire was addressed to radiation oncologists from all centres in Poland who have been certified as specialists after 1990. Of the 212 approached, 103 radiation oncologists responded to the questionnaire (49%). In general, 40% of respondents declared that the majority of tutors/supervisors devoted sufficient time to their training (60% in academic, 28% in regional centres); 60% had access to the literature, and 50% to the internet. The number of treated patients during the training period ranged from 10 to 3000 (median: 375). 69% of the respondents completed a training in another Polish oncology centre (median duration - 2 months), 21% underwent such training abroad, 55% attended international courses/ conferences. Respondents from academic centres had access and attended national and/or international training more often than those from regional centres. Financial matters have been listed as a major obstacle for out-door training by 93% of respondents. 64% of respondents were pleased or rather pleased with the general quality of training, and the remaining 36% were unsatisfied (these mainly from regional centres). Considering career plans, 72% respondents wanted to continue practice at their employing institutions; however 24% have declared a wish to continue their career abroad. This first national survey has shown some weak points in radiotherapy training in Poland, mainly the quality differences between the departments in favour of academic centres. Some of the problems can and should be solved by the Polish Society of Radiation Oncology, others need legislation changes and decisions at the level of the Ministry of Health. (authors)

  8. NRC licensing criteria for portable radwaste systems

    International Nuclear Information System (INIS)

    Hayes, J.J. Jr.

    1983-01-01

    The shortcomings of various components of the liquid and solid radwaste systems at nuclear power reactors has resulted in the contracting of the functions performed by these systems to various contractors who utilize portable equipment. In addition, some streams, for which treatment was not originally anticipated, have been processed by portable equipment. The NRC criteria applicable to portable liquid and solid radwaste systems is presented along with discussion on what is required to provide an adequate 10 CFR Part 50.59 review for those situations where changes are made to an existing system. The criteria the NRC is considering for facilities which may intend to utilize portable incinerators is also presented

  9. Field surveying of radionuclide contamination in forests

    International Nuclear Information System (INIS)

    Turunen, J.; Rantavaara, A.; Ammann, M.

    2009-01-01

    Field measurements of radionuclides after an accidental contamination of forests assume the capacity for identification of a number of nuclides in varying source geometries. The continuous redistribution of radionuclides in forests through natural processes implies a decrease of prevailing surface contamination of trees and an increase in activity density on the ground. Portable gamma spectrometers have long been based on Na(I) detectors which, due to their low energy resolution, are not the tool for analysis of contamination from accidental releases of fission and activation products in the first days or weeks after a deposition. Data of airborne radionuclides from the Chernobyl accident in April 1986 were used for demonstration of initial and later distribution of radionuclides as sources of air Kerma in forests. Forest model (FDMF, PV. 6.0) of the RODOS system was used for the assessment of time-dependent Kerma rate from different forest compartments. The results show the fast reduction of activities of short-lived nuclides and their contributions to the Kerma rate in the first weeks and months. The results also give an estimate for the time needed until a gamma spectrometer with a low energy resolution would give useful information about long-lived radioactivity on the forest floor. An example is given on a portable high resolution semiconductor spectrometer that has suitable characteristics for field surveying also during occurrence of a great number of radionuclides contributing to the gamma spectrum. The needs for further research of a recently deposited radionuclide contamination on forest vegetation and soil, and the efforts for improvement of portable radiation meters and their use in management planning and radioecological research on contaminated forests are discussed. (au)

  10. Nuclear Enterprises portable dose rate meter type PDR4 and external probes types BP1/1, BP8 and GP9

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-08-01

    The performance characteristics of Nuclear Enterprises Portable Dose Rate Meter Type PDR4 are evaluated under the headings: general description, facilities and controls, radiation characteristics, electrical characteristics, environmental characteristics, mechanical characteristics, the manual, summary of performance, and conclusions. Results of an investigation of the radiation characteristics of the external probes Type BP1/1, Type BP8, and Type GP9 are also detailed. (U.K.)

  11. Utilization of portable effluent wastewater in brick manufacturing

    International Nuclear Information System (INIS)

    EI-Mahllawy, M.S.; El-Sokkary, T.M.

    2005-01-01

    Portable wastewater is produced from sedimentation and filtration tanks in portable water treatment plants. Usually, this useless wastewater is drained into River Nile Canal and not to the sewer system causing a potential pollution. Wastewater has been taken from Portable Treatment Plant located at Qalubia Province, Delta, Egypt. Evaluation of raw materials was carried out by using X-ray diffraction (XRD), X-ray fluorescence (XRF), thermal analyses (DTA and TGA) as well as plasticity and drying sensitivity coefficient (DSC) measurements. Technological properties of fired bricks were investigated according to Egyptian and American Specifications. The obtained experimental results encourage substitution of the drained portable wastewater for the tap water in bricks manufacturing. Thus, utilization of the studied portable effluent wastewater in such industry is possible and fulfills the double target of saving drinking water used in clay bricks manufacturing, rather than its environmental pollution prevention. Keywords: Portable wastewater, tap water, clay building bricks, physicomechanical properties

  12. Portable shift register

    International Nuclear Information System (INIS)

    Halbig, J.K.; Bourret, S.C.; Hansen, W.J.; Hicks, D.V.; Klosterbuer, S.F.; Krick, M.S.

    1994-01-01

    An electronics package for a small, battery-operated, self-contained, neutron coincidence counter based on a portable shift-register (PSR) has been developed. The counter was developed for applications not adequately addressed by commercial packages, including in-plant measurements to demonstrate compliance with regulations (domestic and international), in-plant process control, and in-field measurements (environmental monitoring or safeguards). Our package's features, which address these applications, include the following: Small size for portability and ease of installation;battery or mains operation; a built-in battery to power the unit and a typical detector such as a small sample counter, for over 6 h if power lines are bad or noisy, if there is a temporary absence of power, or if portability is desired; complete support, including bias, for standard neutron detectors; a powerful communications package to easily facilitate robust external control over a serial port; and a C-library to simplify creating external control programs in computers or other controllers. Whereas the PSR specifically addresses the applications mentioned above, it also performs all the measurements made by previous electronics packages for neutron coincidence counters developed at Los Alamos and commercialized. The PSR electronics package, exclusive of carrying handle, is 8 by 10 by 20 cm; it contains the circuit boards, battery, and bias supply and weighs less than 2 kg. This instrument package is the second in an emerging family of portable measurement instruments being developed; the first was the Miniature and Modular Multichannel Analyzer (M 3 CA). The PSR makes extensive use of hardware and software developed for the M 3 CA; like the M 3 CA, it is intended primarily for use with an external controller interfaced over a serial channel

  13. A questionnaire survey of medical physicist and quality manager for radiation therapy

    International Nuclear Information System (INIS)

    Nishio, Teiji; Ashino, Yasuo; Onishi, Hiroshi

    2008-01-01

    A questionnaire survey of medical physicists and quality managers for radiation therapy was performed by the Japanese Society for Therapeutic Radiology and Oncology (JASTRO) Future Planning Committee. We mailed the questionnaire to 726 radiotherapy facilities with the answers returned from 353 radiotherapy facilities. The result showed 178 facilities were staffed by radiotherapy workers who were licensed medical physicists or quality managers. A staff of 289 was licensed radiotherapy workers. Most of the staff were radiotherapy technologists. Quality control for radiation therapy was rated satisfactory according to each facility's assessment. Radiation therapy of high quality requires continued education of medical physicists and quality managers, in addition to keeping up with times for quality control. (author)

  14. Aerial radiation survey

    International Nuclear Information System (INIS)

    Pradeep Kumar, K.S.

    1998-01-01

    Aerial gamma spectrometry surveys are the most effective, comprehensive and preferred tool to delimit the large area surface contamination in a radiological emergency either due to a nuclear accident or following a nuclear strike. The airborne survey apart from providing rapid and economical evaluation of ground contamination over large areas due to larger ground clearance and higher speed, is the only technique to overcome difficulties posed by ground surveys of inaccessible region. The aerial survey technique can also be used for searching of lost radioactive sources, tracking of radioactive plume and generation of background data on the Emergency Planning Zone (EPZ) of nuclear installations

  15. Alpha particle response for a prototype radiation survey meter based on poly(ethylene terephthalate) with un-doping fluorescent guest molecules

    International Nuclear Information System (INIS)

    Nguyen, Philip; Nakamura, Hidehito; Sato, Nobuhiro; Takahashi, Tomoyuki; Maki, Daisuke; Kanayama, Masaya; Takahashi, Sentaro; Kitamura, Hisashi; Shirakawa, Yoshiyuki

    2016-01-01

    There is no radiation survey meter that can discriminate among alpha particles, beta particles, and gamma-rays with one material. Previously, undoped poly(ethylene terephthalate) (PET) has been shown to be an effective material for beta particle and gamma-ray detection. Here, we demonstrate a prototype survey meter for alpha particles based on undoped PET. A 140 × 72 × 1-mm PET substrate was fabricated with mirrored surfaces. It was incorporated in a unique detection section of the survey meter that directly detects alpha particles. The prototype exhibited an unambiguous response to alpha particles from a 241 Am radioactive source. These results demonstrate that undoped PET can perform well in survey meters for alpha particle detection. Overall, the PET-based survey meter has the potential to detect multiple types of radiation, and will spawn an unprecedented type of radiation survey meter based on undoped aromatic ring polymers. (author)

  16. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  17. Portable direct methanol fuel cell systems

    Science.gov (United States)

    Narayanan, S. R.; Valdez, T. I.

    2002-01-01

    This article includes discussion of the specific power and power density requirements for various portable system applications, the status of stack technology, progress in the implementation of balance-of-plant designs, and a summary of the characteristics of various DMFC portable power source demonstrations.

  18. The Economics of Educational Software Portability.

    Science.gov (United States)

    Oliveira, Joao Batista Araujo e

    1990-01-01

    Discusses economic issues that affect the portability of educational software. Topics discussed include economic reasons for portability, including cost effectiveness; the nature and behavior of educational computer software markets; the role of producers, buyers, and consumers; potential effects of government policies; computer piracy; and…

  19. One of the First Portable Macs

    CERN Multimedia

    1989-01-01

    It was one of the first portable macs released. The Portable had many new advances in mobile computing : The display was crispy clear, and looked beautiful when used in daylight ; The Portable came with a Lead-acid gel/cell battery that could run a anywhere from 6 -12 hours ; It supported to internal hard drives, and an external one. The reaction to the laptop was weak because it was slow, it had no capacity for expansion, it weighed heavily, its price was expensive. It has been stayed 1 year and half on the market.

  20. Making Nuclear Malaysia Email Archives Portable

    International Nuclear Information System (INIS)

    Shaharum Ramli

    2013-01-01

    Nuclear Malaysia e-mails can be accessed from any computer and anywhere, even worldwide, via web access. However, this mobility is lost when the e-mails are moved to a personal computer into archive files such as Microsoft Outlook data files. Outlook e-mail archives can only be read on the computer where it is stored. This removal has to be done because of storage space constraints on the e-mail server. This paper shows how e-mail archives can be made portable, brought and read anywhere using a free portable e-mail client application such as Mozilla Thunderbird, Portable Edition. (author)

  1. Current status of brachytherapy in Korea: a national survey of radiation oncologists.

    Science.gov (United States)

    Kim, Haeyoung; Kim, Joo Young; Kim, Juree; Park, Won; Kim, Young Seok; Kim, Hak Jae; Kim, Yong Bae

    2016-07-01

    The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information on human resources, brachytherapy equipment, and suggestions for future directions of brachytherapy policy in Korea. The response rate of the survey was 88.3%. The average number of radiation oncologists per center was 2.3. At the time of survey, 28 centers (36.8%) provided brachytherapy to patients. Among the 28 brachytherapy centers, 15 (53.5%) were located in in the capital Seoul and its surrounding metropolitan areas. All brachytherapy centers had a high-dose rate system using (192)Ir (26 centers) or (60)Co (two centers). Among the 26 centers using (192)Ir sources, 11 treated fewer than 40 patients per year. In the two centers using (60)Co sources, the number of patients per year was 16 and 120, respectively. The most frequently cited difficulties in performing brachytherapy were cost related. A total of 21 centers had a plan to sustain the current brachytherapy system, and four centers noted plans to upgrade their brachytherapy system. Two centers stated that they were considering discontinuation of brachytherapy due to cost burdens of radioisotope source replacement. The present study illustrated the current status of brachytherapy in Korea. Financial difficulties were the major barriers to the practice of brachytherapy.

  2. External gamma radiation survey for oil wellheads in Saudi Arabia

    International Nuclear Information System (INIS)

    Nassar, Rafat M.; Mously, Khalid A.; Cowie, Michael I.

    2008-01-01

    Naturally occurring radioactive material (NORM) is known to be associated with oil and gas extraction. As part of a comprehensive NORM management strategy, Saudi Aramco needed to determine the extent of NORM contamination associated with their oil and gas operations. As part of that strategy, this study focused on external gamma survey of oil producing wellheads at various locations. The study aimed to: 1-) Identify wellheads with elevated gamma radiation dose rate; 2-) Specify the exact locations of the high dose rates on the wellheads; 3-) Identify the radioisotopes responsible for the high dose rates; and 4-) Propose worker protection requirements during maintenance. The majority (∼92%) of the surveyed wellheads showed no enhanced gamma dose-rate above background level. From the remaining ∼8%, only a few wellheads showed dose rates between 1,000-3,700 n Sv/h. The study revealed that NORM contamination tends to accumulate at turns of the pipes, around pipe diameter changes, the joints, the back of valves, and at the base of the wellhead. Also, for a given location, NORM build up on the interior of pipework varies over time and continues to migrate down stream until it reaches the Gas and Oil Separation Plants (GOSP). There NORM is expected to accumulate and reside in the form of sludge. Gamma spectroscopy analysis revealed that 226 Ra and its progeny are responsible for the high radiation dose rates detected. It was concluded that NORM will not pose significant radiation hazards to workers as long as the tubing and piping are not opened. (author)

  3. Environmental radiation sensing technologies

    International Nuclear Information System (INIS)

    Nishizawa, Hiroshi; Inomata, Kenji; Tamuro, Masaru; Fujita, Kazuhiko

    2013-01-01

    After the Fukushima nuclear accident, environmental radiation monitoring and radioactivity measurement of contamination of wastes, soils, food and drinking water were needed in accurate and reliable way. Based on radiation sensing technologies and radiation and light coupled analysis method, new environmental radiation measurement system for simple monitoring post without exclusive house and also portable monitoring post for temporary use were developed with low cost. Measurement accuracy was improved by real-time processing of detected pulses and corrected non-linearity of low-energy range by analysis. Environmental performance was upgraded to assure detector gain with compensated against temperature change and aging. Inspection and maintenance were also simplified using touch panel display with standardized application menu and data format. (T. Tanaka)

  4. Portable instrument for measuring neutron energy spectra and neutron dose in a mixed n-γ field

    International Nuclear Information System (INIS)

    Daniels, C. J.; Silberberg, J. L.

    1980-01-01

    A portable high-speed neutron spectrometer consists of an organic scintillator, a true zero-crossing pulse shape discriminator, a 1 MHZ conversion-rate multichannel analyzer, an 8-bit microcomputer, and appropriate displays. The device can be used to measure neutron energy spectra and kerma rate in intense n- gamma radiation fields in which the neutron energy is from 5 to 15 MEV

  5. A next generation field-portable goniometer system

    Science.gov (United States)

    Harms, Justin D.; Bachmann, Charles M.; Faulring, Jason W.; Ruiz Torres, Andres J.

    2016-05-01

    Various field portable goniometers have been designed to capture in-situ measurements of a materials bi-directional reflectance distribution function (BRDF), each with a specific scientific purpose in mind.1-4 The Rochester Institute of Technology's (RIT) Chester F. Carlson Center for Imaging Science recently created a novel instrument incorporating a wide variety of features into one compact apparatus in order to obtain very high accuracy BRDFs of short vegetation and sediments, even in undesirable conditions and austere environments. This next generation system integrates a dual-view design using two VNIR/SWIR pectroradiometers to capture target reflected radiance, as well as incoming radiance, to provide for better optical accuracy when measuring in non-ideal atmospheric conditions or when background illumination effects are non-negligible. The new, fully automated device also features a laser range finder to construct a surface roughness model of the target being measured, which enables the user to include inclination information into BRDF post-processing and further allows for roughness effects to be better studied for radiative transfer modeling. The highly portable design features automatic leveling, a precision engineered frame, and a variable measurement plane that allow for BRDF measurements on rugged, un-even terrain while still maintaining true angular measurements with respect to the target, all without sacrificing measurement speed. Despite the expanded capabilities and dual sensor suite, the system weighs less than 75 kg, which allows for excellent mobility and data collection on soft, silty clay or fine sand.

  6. Assessment of radiological profile of Mumbai - Kota rail route using mobile monitoring methodology

    International Nuclear Information System (INIS)

    Saindane, Shashank S.; Anoj Kumar; Narsaiah, M.V.R.; Mishra, A.K.; Solase, Sachin; Murali, S.; Pradeepkumar, K.S.

    2014-01-01

    Radiological mapping is useful for updates on the trend of the radiation level at various locations/routes. As a part of this, the radiation mapping of Mumbai - Kota rail route (∼ 1230 km) was carried out by using various state of the art monitoring systems/instruments to record the radiation level both on online and offline modes. The state of the art monitoring systems/instruments such as Compact Radiation monitoring system, Gamma Tracer, Field Spec and portable spectrometer equipped with Global Positioning System were installed inside the train compartment. The dose rate data were noted manually also at various stations using highly sensitive portable instruments like Micro R (μR) survey meter, Field spec, Personal Radiation Detector (PRD) etc. With the help of portable spectrometer, spectral data were continuously collected along the route

  7. Detection device of dangerous radiation for the living beings

    International Nuclear Information System (INIS)

    Lacoste, F.

    1991-01-01

    This invention is about a portable device able to measure dose rates or doses of gamma, ultraviolet and X radiation or charged particles. This device is composed of a radiation detector, a calculator of the accumulate dose and a memory to store the data. This device has a credit card format

  8. Radiation levels from computer monitor screens within Benue State ...

    African Journals Online (AJOL)

    Investigation of possible presence of soft X-ray levels from Computer Screens at distances of 0.5m and 1.0m was carried out within Benue State University, Makurdi, using ten different monitor models. Radiation measurement was carried out using a portable digital radiation meter, INSPECTOR 06250 (SE international Inc.

  9. Portable Pbars, traps that travel

    International Nuclear Information System (INIS)

    Howe, S.D.; Hynes, M.V.; Picklesimer, A.

    1987-10-01

    The advent of antiproton research utilizing relatively small scale storage devices for very large numbers of these particles opens the possibility of transporting these devices to a research site removed from the accelerator center that produced the antiprotons. Such a portable source of antiprotons could open many new areas of research and make antiprotons available to a new research community. At present antiprotons are available at energies down to 1 MeV. From a portable source these particles can be made available at energies ranging from several tens of kilovolts down to a few millielectron volts. These low energies are in the domain of interest to the atomic and condensed matter physicist. In addition such a source can be used as an injector for an accelerator which could increase the energy domain even further. Moreover, the availability of such a source at a university will open research with antiprotons to a broader range of students than possible at a centralized research facility. This report focuses on the use of ion traps, in particular cylindrical traps, for the antiproton storage device. These devices store the charged antiprotons in a combination of electric and magnet fields. At high enough density and low enough temperature the charged cloud will be susceptible to plasma instabilities. Present day ion trap work is just starting to explore this domain. Our assessment of feasibility is based on what could be done with present day technology and what future technology could achieve. We conclude our report with a radiation safety study that shows that about 10 11 antiprotons can be transported safely, however the federal guidelines for this transport must be reviewed in detail. More antiprotons than this will require special transportation arrangements. 28 refs., 8 figs

  10. A survey of radiation synovectomy in Europe, 1991-1993

    International Nuclear Information System (INIS)

    Clunie, G.; Ell, P.J.

    1995-01-01

    We have evaluated radiation synovectomy practice in Europe over the period 1991-1993 by means of a postal questionnaire. More than 2300 European members of the European Association of Nuclear Medicine were questioned about the number of treated patients and joints, disease prevalence in their patients and the use of radiopharmaceuticals. Overall, 119/490 (24%) of centres replying to the survey practised radiation synovectomy during the 3 years. There were 13450 different joint injections in 8578 patients. Rheumatoid arthritis was the most prevalent disease in patients treated (71%) and the most frequently treated joints were knee (46%) and finger joints (20%). Eight different radiopharmaceuticals were employed. Yttrium-90 colloids were most frequently and widely (100/119 centres) used, mainly employed for knee synovectomy but were also used to treat most appendicular joints. Erbium-169 colloid was almost exclusively used to treat finger joints (31/33 centres). Corticosteroid was routinely co-injected in 36/60 (60%) centres. Radiation synovectomy was widely practised throughout Europe during 1991-1993. There are variations in practice illustrated by the diversity of treated arthritides and injected joints and by the use and application of different radiopharmaceuticals. (orig.). With 7 figs., 1 tab

  11. Radiation survey and management on the reconstructed radioactive work-site

    International Nuclear Information System (INIS)

    Yu Tao; Liang Shiqiang; Wang Youmei

    2004-12-01

    The experiences of radiation survey and administration in the prophase on reconstructed radioactive work-site are summarized. The advance works are to investigate the reconstructed work-site, settle working plans, devise inspecting flow charts, deal with something in time in the local and train the staffers. The works about prophasic decontaminating, removing and cleaning up the site have been finished, which have established the deep foundation to develop later task. (authors)

  12. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  13. Radiation distribution measurement using plastic scintillating optical fibers for survey of radioactive contamination in wide area

    International Nuclear Information System (INIS)

    Ito, Chikara; Ito, Keisuke; Ishikawa, Takashi; Yoshida, Akihiro; Sanada, Yukihisa; Torii, Tatsuo; Nohtomi, Akihiro; Wakabayashi, Genichiro; Miyazaki, Nobuyuki

    2013-01-01

    It is important to examine distribution of environmental contamination due to the accident of Fukushima Daiichi Nuclear Power Station and to confirm the effect of decontamination works. We have applied radiation distribution measurement using plastic scintillating optical fibers (PSFs) in the survey of contamination in wide area including residential, farmland, forests, etc. In the measurements system, two scintillation lights that emitted at an incidence of a radiation transmit to photomultiplier tubes at the both end of PSFs. The position where scintillation light emitted is obtained from the detection time difference of each photomultiplier tube. The distribution of light emission quantity indicates the distribution of radiation incident in a PSF which is corresponds to the distribution of dose-rate. The radiation detection system using the PSFs has been applied to the radiation distribution measurement on grounds, trees, etc. The results show a good agreement with point data measured by survey meters using sodium iodide scintillators. As the PSFs which have water resistance, they have been successfully applied to the radiation distribution measurement in the river. We have also succeeded in measuring two-dimensional distribution of radiation by measuring the count rate while moving to the fiber at a constant speed. (author)

  14. Dose inspection and risk assessment on radiation safety for the use of non-medical X-ray machines in Taiwan

    Science.gov (United States)

    Hsu, Fang-Yuh; Hsu, Shih-Ming; Chao, Jiunn-Hsing

    2017-11-01

    The subject of this study is the on-site visits and inspections of facilities commissioned by the Atomic Energy Council (AEC) in Taiwan. This research was conducted to evaluate the possible dose and dose rate of cabinet-type X-ray equipment with nominal voltages of 30-150 kV and open-beam (portable or handheld) equipment, taking both normal operation and possibly abnormal operation conditions into account. Doses and dose rates were measured using a plastic scintillation survey meter and an electronic personal dosimeter. In total, 401 X-ray machines were inspected, including 139 units with nominal voltages of 30-50 kV X-ray equipment, 140 units with nominal voltages of 50-150 kV, and 122 open-beam (portable or handheld) X-ray equipment. The investigated doses for radiation workers and non-radiation workers operating cabinet-type X-ray equipment under normal safety conditions were all at the background dose level. Several investigated dose rates at the position of 10 cm away from the surface of open-beam (portable or handheld) X-ray equipment were very high, such X-ray machines are used by aeronautical police for the detection of suspected explosives, radiation workers are far away (at least 10 m away) from the X-ray machine during its operation. The doses per operation in X-ray equipment with a 30-50 kV nominal voltage were less than 1 mSv in all cases of abnormal use. Some doses were higher than 1 mSv per operation for X-ray equipment of 50-150 kV nominal voltage X-ray. The maximum dose rates at the beam exit have a very wide range, mostly less than 100 μSv/s and the largest value is about 3.92 mSv/s for open-beam (portable or handheld) X-ray devices. The risk induced by operating X-ray devices with nominal voltages of 30-50 kV is extremely low. The 11.5 mSv dose due to one operation at nominal voltage of 50-150 kV X-ray device is equivalent to the exposure of taking 575 chest X-rays. In the abnormal use of open-beam (portable or handheld) X-ray equipment, the

  15. Development of aerial gamma radiation survey system, 4

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Nagaoka, Toshi; Sakamoto, Ryuichi; Tsutsumi, Masahiro; Moriuchi, Shigeru

    1985-02-01

    Field experiments have been performed by JAERI since 1982 to obtain fundamental data required for development of aerial radiation survey system. In order to supplement the fundamental radiation data, theoretical calculations have been carried out. The utilized Monte Carlo transport program was verified by simulative calculations of the field experiments, and characteristics data on environmental gamma rays have been accumulated. In this report, the field experiments in 1981 and 1982 were simulated making use of the Monte Carlo transport calculation code YURI developed in JAERI. Comparisons were made between experimental and calculated results for exposure rate and flux density originated from terrestrial sources, and from a point source at height of 2.5 m above the ground. Good agreements between the data verified the transport program. As fundamental characteristics data on environmental gamma rays, spatial distributions of exposure, fluence, energy spectra, angular spectra and average energy were reported and discussed, for terrestrial sources of 40 K, 232 Th-series and 238 U-series, for a plane source on the ground and for a point source at 2.5 m above the ground. (author)

  16. PORTABLE PEM FUEL CELL SYSTEM: WATER AND HEAT MANAGEMENT

    Directory of Open Access Journals (Sweden)

    SITI NAJIBAH ABD RAHMAN

    2016-07-01

    Full Text Available Portable polymer electrolyte membrane (PEM fuel cell power generator is a PEM fuel cell application that is used as an external charger to supply the demand for high energy. Different environments at various ambient temperatures and humidity levels affect the performance of PEM fuel cell power generators. Thermal and water management in portable PEM fuel cells are a critical technical barrier for the commercialization of this technology. The size and weight of the portable PEM fuel cells used for thermal and water management systems that determine the performance of portable PEM fuel cells also need to be considered. The main objective of this paper review was to determine the importance of water and thermal management systems in portable PEM fuel cells. Additionally, this review investigated heat transfer and water transport in PEM fuel cells. Given that portable PEM fuel cells with different powers require different thermal and water management systems, this review also discussed and compared management systems for low-, medium-, and high-power portable PEM fuel cells.

  17. A background radiation survey along the transcontinental railway in Australia

    International Nuclear Information System (INIS)

    Minato, Susumu; Kodaira, Kazuo; Ito, Masaru

    1995-01-01

    This article reports a survey, carried out during a period from October 31 to November 3, 1994 in Australia, as well as some basic techniques of train-borne measurements for estimating outdoor gamma-ray dose rates. Surface rock and bedrock data are presented for convenience for geological analysis. Cosmic-ray dose rates estimated from atmospheric pressure data are also presented for researchers who are interested in total background radiation dose rates. It was found that gamma levels can be high in the western area. The dose rate data were based on the shielding correction factor evaluated at platforms in many stations. To confirm the validity of this method, the data from train-borne surveys in central Japan were compared with the present Australian data. There were, to some extent, correlations between them. The present study suggests that the train-borne measurements are useful for surveying wide area in a short time with an error of about 20%. (N.K.)

  18. Design of the power sources for portable nuclear instruments

    International Nuclear Information System (INIS)

    Chen Wei; Fang Fang; Cui Yan; Cui Junliang; Zhou Wei

    2007-01-01

    How to charge for the portable equipments is always a topical subject aimed by people, the application of new type batteries and Battery Management brings great facility to people's life, the rechargeable battery for portable equipments is widely used in portable equipments, but the convenience of the charging power source is limited in special situation. This paper will discuss how to combining rechargeable battery with traditional alkaline batteries for charging the portable instruments. (authors)

  19. Cosmic radiation algorithm utilizing flight time tables

    International Nuclear Information System (INIS)

    Katja Kojo, M.Sc.; Mika Helminen, M.Sc.; Anssi Auvinen, M.D.Ph.D.; Katja Kojo, M.Sc.; Anssi Auvinen, M.D.Ph.D.; Gerhard Leuthold, D.Sc.

    2006-01-01

    Cosmic radiation is considerably higher on cruising altitudes used in aviation than at ground level. Exposure to cosmic radiation may increase cancer risk among pilots and cabin crew. The International Commission on Radiation Protection (ICRP) has recommended that air crew should be classified as radiation workers. Quantification of cosmic radiation doses is necessary for assessment of potential health effects of such occupational exposure. For Finnair cabin crew (cabin attendants and stewards), flight history is not available for years prior to 1991 and therefore, other sources of information on number and type of flights have to be used. The lack of systematically recorded information is a problem for dose estimation for many other flight companies personnel as well. Several cosmic radiation dose estimations for cabin crew have been performed using different methods (e.g. 2-5), but they have suffered from various shortcomings. Retrospective exposure estimation is not possible with personal portable dosimeters. Methods that employ survey data for occupational dose assessment are prone to non-differential measurement error i.e. the cabin attendants do not remember correctly the number of past flights. Assessment procedures that utilize surrogate measurement methods i.e. the duration of employment, lack precision. The aim of the present study was to develop an assessment method for individual occupational exposure to cosmic radiation based on flight time tables. Our method provides an assessment method that does not require survey data or systematic recording of flight history, and it is rather quick, inexpensive, and possible to carry out in all other flight companies whose past time tables for the past periods exist. Dose assessment methods that employ survey data are prone to random error i.e. the cabin attendants do not remember correctly the number or types of routes that they have flown during the past. Our method avoids this since survey data are not needed

  20. Variation of Natural Gamma Radiation in Isparta

    International Nuclear Information System (INIS)

    Akkurt, I.

    2004-01-01

    There is always a radiation in the earth, and its level is generated primarily by galactic cosmic rays (GCR), consisting of energetic nuclei of all naturally occurring elements, interacting with atmospheric constituents, through atomic and nuclear collisions. The other sources of natural radiations are global average background radiation from terrestrial sources such as soils, rocks ete. Background radiation levels in the atmosphere vary in intensity with latitude, altitude and phase of the solar cycle. Variation of natural radiation as a function of altitude, geological structure etc has been investigated. The measurements were performed using portable radiation counter which connected to NaI(Tl) probe

  1. Monitoring and crisis system of radiation safety

    International Nuclear Information System (INIS)

    Bartok, J.; Borovansky, P.; Macica, J.; Petrovicova, M.

    2005-01-01

    In this paper we have briefly described our practical experiences with the most complex Radiation Monitoring System we have designed. This system consists of number of stations; those data are collected in the main crisis center of the whole system. The main center integrates RMS Central Database, the IMS Model Suite workstation and the Graphics workstation. The radiations probes of the RP series are the base for stationary , portable sets and for sets measuring underwater radiation. The radiation and meteorological data, which are necessary for reasonable interpretation of radiation data, are archived in RMS Central database. The Lagrangian trajectory model from the IMS Model Suite serves for radiation dispersion modeling. (authors)

  2. Sampling strategy for a large scale indoor radiation survey - a pilot project

    International Nuclear Information System (INIS)

    Strand, T.; Stranden, E.

    1986-01-01

    Optimisation of a stratified random sampling strategy for large scale indoor radiation surveys is discussed. It is based on the results from a small scale pilot project where variances in dose rates within different categories of houses were assessed. By selecting a predetermined precision level for the mean dose rate in a given region, the number of measurements needed can be optimised. The results of a pilot project in Norway are presented together with the development of the final sampling strategy for a planned large scale survey. (author)

  3. Radiation exposure and radiation hazards of human population. Pt. 1

    International Nuclear Information System (INIS)

    Jacobi, W.

    1982-01-01

    The present Part I provides a survey on the various sources of natural and artificial radiation exposure of human population. Furthermore, biological radiation effects and radiation damages are surveyed. In an appendix, radiation types, radiation doses, and radiation dose units are explained. (orig./GSCH) [de

  4. Semi-Quantitative Evaluation of Secondary Carbonates via Portable X-ray Fluorescence Spectrometry

    Science.gov (United States)

    Chakraborty, Somsubhra; Weindorf, David; Weindorf, Camille; Duda, Bogdan; Pennington, Sarah; Ortiz, Rebekah

    2017-04-01

    Secondary calcium carbonate commonly occurs in subsoils of semi-arid soils worldwide. In US Soil Taxonomy, such horizons are frequently described as Bk, Bkk, Bkm, Bkkm, or Ck horizons at variable stages of development. Specifically, the Soil Survey Staff uses a qualitative scale of one through six to indicate differential developmental stages. However, considerable disagreement exists even among experienced soil scientists. Evaluating 75 soil samples from across four US states, a portable X-ray fluorescence (PXRF) spectrometer was used to quantify the total soil Ca content and compare it to average developmental stage scores as determined by a panel of Soil Survey Staff personnel. Samples were evaluated both as intact aggregates as well as ground (human eye.

  5. Thickness Measurement of V2O5 Nanometric Thin Films Using a Portable XRF

    Directory of Open Access Journals (Sweden)

    Fabio Lopes

    2016-01-01

    Full Text Available Nanometric thin films have always been chiefly used for decoration; however they are now being widely used as the basis of high technology. Among the various physical qualities that characterize them, the thickness strongly influences their properties. Thus, a new procedure is hereby proposed and developed for determining the thickness of V2O5 nanometric thin films deposited on the glass surface using Portable X-Ray Fluorescence (PXRF equipment and the attenuation of the radiation intensity Kα of calcium present in the glass. It is shown through the present paper that the radiation intensity of calcium Kα rays is proportional to film thickness in nanometric films of vanadium deposited on the glass surface.

  6. Bagworm bags as portable armour against invertebrate predators

    Directory of Open Access Journals (Sweden)

    Shinji Sugiura

    2016-02-01

    Full Text Available Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae. Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators’ mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.

  7. Bagworm bags as portable armour against invertebrate predators.

    Science.gov (United States)

    Sugiura, Shinji

    2016-01-01

    Some animals have evolved the use of environmental materials as "portable armour" against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators' mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.

  8. Gamin partable radiation meter with alarm threshold

    International Nuclear Information System (INIS)

    Payat, Rene.

    1981-10-01

    The Gamin Radiation meter is a direct reading, portable, battery-powered gamma doserate meter featuring alarm thresholds. Doserate is read on a micro-ammeter with a millirad-per-hour logarithmic scale, covering a range of 0,1 to 1000 millirads/hour. The instrument issues an audible warning signal when dose-rate level exceeds a threshold value, which can be selected. The detector tube is of the Geiger-Muller counter, energy compensated type. Because of its low battery drain, the instrument can be operated continously for 1000 hours. It is powered by four 1.5 volt alcaline batteries of the R6 type. The electronic circuitry is housed in a small lightweight case made of impact resistant plastic. Applications of the Gamin portable radiation monitor are found in health physics, safety departments, medical facilities, teaching, civil defense [fr

  9. Field applications of the ScoutTM portable MCA

    International Nuclear Information System (INIS)

    Cheng, A.Y.; Ziemba, F.P.; Browning, J.E.

    1998-01-01

    The use of Quantrad Sensor's Scout TM in field type applications is described. The portability of the Scout TM enables the user to obtain more accurate information in the field versus a survey meter. Isotopic identification is possible when ancillary information is combined with built-in software libraries. Data from the Scout TM in remediation at Stanford Linear Accelerator (SLAC), NORM (Naturally Occurring Radioactive Material) measurements in California's Central Valley oil fields, medical isotope identification at nuclear pharmaceutical company and emergency response applications are presented. Additionally, custom software enabled the use of the Scout TM in identification, qualification and detection of Special Nuclear Materials (SNM) in illicit trafficking and portal monitoring applications. (author)

  10. A high resolution portable spectroscopy system

    International Nuclear Information System (INIS)

    Kulkarni, C.P.; Vaidya, P.P.; Paulson, M.; Bhatnagar, P.V.; Pande, S.S.; Padmini, S.

    2003-01-01

    Full text: This paper describes the system details of a High Resolution Portable Spectroscopy System (HRPSS) developed at Electronics Division, BARC. The system can be used for laboratory class, high-resolution nuclear spectroscopy applications. The HRPSS consists of a specially designed compact NIM bin, with built-in power supplies, accommodating a low power, high resolution MCA, and on-board embedded computer for spectrum building and communication. A NIM based spectroscopy amplifier and a HV module for detector bias are integrated (plug-in) in the bin. The system communicates with a host PC via a serial link. Along-with a laptop PC, and a portable HP-Ge detector, the HRPSS offers a laboratory class performance for portable applications

  11. Epidemiological survey of radiation workers. Risk of leukemia and solid cancer by low level radiation exposure

    International Nuclear Information System (INIS)

    Tatsumi, Kouichi

    2011-01-01

    An interim report on the epidemiological survey of cohort involving radiation workers in the nuclear power plants in Japan was introduced. It consists of eight chapters such as introduction, the objects of mortality rate survey from death causes and creating a cohort, the method of tracking the life and death, analytical methods of mortality rate, analytical results, confounded effects of life style, discussion: contrast the report on the mortality rate of solid cancer except leukemia in Japan and other countries and the conclusions. The subjects of mortality rate of the forth survey were about 277,000 workers including from the first to the third survey. In a prospective cohort study, 203,904 workers were screened for analytical study, and they included 14,224 deaths (5,711 from malignant neoplasm, 6,310 from nonmalignant neoplasm and 1,995 from extrinsic death). The analytical results were shown by three types of death caused from leukemia, malignant neoplasm except for leukemia and nonmalignant neoplasm. Analytical results of the mortality rate from death caused in third and forth study, change of analytical results from the first to the forth observation period were illustrated. (S.Y.)

  12. Robotic radiation survey and analysis system for radiation waste casks

    International Nuclear Information System (INIS)

    Thunborg, S.

    1987-01-01

    Sandia National Laboratories (SNL) and the Hanford Engineering Development Laboratories have been involved in the development of remote systems technology concepts for handling defense high-level waste (DHLW) shipping casks at the waste repository. This effort was demonstrated the feasibility of using this technology for handling DHLW casks. These investigations have also shown that cask design can have a major effect on the feasibility of remote cask handling. Consequently, SNL has initiated a program to determine cask features necessary for robotic remote handling at the waste repository. The initial cask handling task selected for detailed investigation was the robotic radiation survey and analysis (RRSAS) task. In addition to determining the design features required for robotic cask handling, the RRSAS project contributes to the definition of techniques for random selection of swipe locations, the definition of robotic swipe parameters, force control techniques for robotic swipes, machine vision techniques for the location of objects in 3-D, repository robotic systems requirements, and repository data management system needs

  13. Database on epidemiological survey in high background radiation research

    International Nuclear Information System (INIS)

    Zhou Sunyuan; Guo Furong; Liu Yusheng

    1992-01-01

    In order to store and check the data of the health survey in high background radiation area (HBRA) and control area in Guangdong Province, and to use these data in future, three databases were set up by using RBASE 5000 database software. (1) HD: the database based on the household registers especially established for the health survey from 1979 to 1986, covering more than 160000 subjects and 2200000 data. (2) DC: the database based on the registration cards of deaths from cancers and all other diseases during the period of 1975-1986 including more than 10000 cases and 260000 data. (3) MCC: the database for the case-control study on mutation-related factors for four kinds of cancers (liver, stomach, lung cancers and leukemia), embracing 626 subjects and close to 90000 data. The data in the databases were checked up with the original records and compared with the manual analytical results

  14. Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam.

    Science.gov (United States)

    Urbinello, Damiano; Huss, Anke; Beekhuizen, Johan; Vermeulen, Roel; Röösli, Martin

    2014-01-15

    Radiofrequency electromagnetic fields (RF-EMF) are highly variable and differ considerably within as well as between areas. Exposure assessment studies characterizing spatial and temporal variation are limited so far. Our objective was to evaluate sources of data variability and the repeatability of daily measurements using portable exposure meters (PEMs). Data were collected at 12 days between November 2010 and January 2011 with PEMs in four different types of urban areas in the cities of Basel (BSL) and Amsterdam (AMS). Exposure from mobile phone base stations ranged from 0.30 to 0.53 V/m in downtown and business areas and in residential areas from 0.09 to 0.41 V/m. Analysis of variance (ANOVA) demonstrated that measurements from various days were highly reproducible (measurement duration of approximately 30 min) with only 0.6% of the variance of all measurements from mobile phone base station radiation being explained by the measurement day and only 0.2% by the measurement time (morning, noon, afternoon), whereas type of area (30%) and city (50%) explained most of the data variability. We conclude that mobile monitoring of exposure from mobile phone base station radiation with PEMs is useful due to the high repeatability of mobile phone base station exposure levels, despite the high spatial variation. © 2013.

  15. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  16. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  17. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  18. Smart portable rehabilitation devices.

    Science.gov (United States)

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  19. Epidemiological survey of the effects of low level radiation dose: a comparative assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K.S.B.

    1993-10-01

    This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

  20. iPad Portable Genius

    CERN Document Server

    McFedries, Paul

    2010-01-01

    Everything everyone wants to know about using the Apple iPad. On January 27, 2010, Apple announced the latest in its line of revolutionary, ultraportable devices - the iPad. iPad Portable Genius is the latest in a line of ultra handy, go-to and goes-with you anywhere guides for getting the most out of a new Apple product. Written to provide readers with highly useful information that's easily accessible, iPad Portable Genius is full of tips, tricks and techniques for maximizing each of the iPad's most popular features.:; Designed in full-color with an Apple look and feel, and written in a hip,

  1. Geophex airborne unmanned survey system

    International Nuclear Information System (INIS)

    Won, I.J.; Taylor, D.W.A.

    1995-01-01

    The purpose of this effort is to design, construct, and evaluate a portable, remotely-piloted, airborne, geophysical survey system. This nonintrusive system will provide open-quotes stand-offclose quotes capability to conduct surveys and detect buried objects, structures, and conditions of interest at hazardous locations. This system permits two operators to rapidly conduct geophysical characterization of hazardous environmental sites. During a survey, the operators remain remote from, but within visual distance, of, the site. The sensor system never contacts the Earth, but can be positioned near the ground so that weak anomalies can be detected

  2. Portable Tablets in Science Museum Learning: Options and Obstacles

    Science.gov (United States)

    Gronemann, Sigurd Trolle

    2017-01-01

    Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the…

  3. Operating experience of a portable thermophotovoltaic power supply

    Science.gov (United States)

    Becker, Frederick E.; Doyle, Edward F.; Shukla, Kailash

    1999-03-01

    Two configurations of man-portable thermophotovoltaic (TPV) power supplies based on Thermo Power's supported continuous fiber emitter have been designed, built, and are being tested. The systems use narrow-band, fibrous, ytterbia emitters radiating to bandgap matched silicon photovoltaic arrays with dielectric stack filters for optical energy recovery and recuperators for thermal energy recovery. The systems have been designed for operation with propane and with combustion air preheat temperatures of up to 1250 K. To operate at air preheat temperatures above the auto-ignition temperature of the fuel, a unique fuel delivery system was devised which results in the micromixing and rapid combustion of the fuel and air right in the emitter fibers. This allows the ytterbia emitter fibers to run much hotter (˜2000 K) than any of the surrounding structure.

  4. Rapid measurement of 131I in the thyroid gland using a portable Ge system

    International Nuclear Information System (INIS)

    Kawamura, H.; Kimura, S.

    2000-01-01

    Rapid yet accurate measurement of the 131 I activity in the thyroid gland as well as in the air, water and vegetation may have an important role in obtaining quantitative information on internal doses for the people living in the vicinity of nuclear facilities shortly after an accidental release of radionuclides. Whole body counting technique is still the standard method for measuring radionuclides in the body while necessity for in situ measurement techniques has considerably increased especially after the Three Mile Island and Chernobyl accidents. For measurement of 131 I in the thyroid gland in emergency situations, NaI (Tl) detectors, as in a scintillation survey meter as in the simplest case, are most often used while measurement of urinary excretions for members of the public may also effective. The scintillation survey meter method, being easily implemented, may not have enough selectivity for radioiodine and even be liable to an elevated background radiation spectrum. This would possibly lead to higher detection limits and lower accuracy. A use of a laboratory Ge (Li) detector system in the thyroidal radioiodine measurement was suggested to overcome the problem. A real measurement with a similar instrument was reported for the residents in U.K. after the Chernobyl accident. A use of a scintillation spectro-survey meter with a NaI (Tl) probe with lead collimation to thyroidal radioiodine measurement was also reported to give satisfactorily accurate evaluation of the thyroidal 131 I burden. In this paper, a movable Ge system was developed for the above purpose and preliminarily evaluated particularly for counting efficiency. It is consisted of a portable high-purity Ge detector and a battery-operated MCA. It employs a laboratory made thin Pb shield with a collimation window and an elevator for the detector platform. The elevator was designed to adjust the height of the thyroid radioiodine probe in relation to the height and position of the neck of a subject

  5. Bagworm bags as portable armour against invertebrate predators

    OpenAIRE

    Sugiura, Shinji

    2016-01-01

    Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a po...

  6. Survey of cognition on nuclear and radiation in Beijing high school students

    International Nuclear Information System (INIS)

    Wang Chao; He Jianrong; Zhu Xiayang; Yang Guoliang; Cong Huiling; Hu Qinfang

    2014-01-01

    Objective: To explore cognition level on nuclear and radiation in Beijing high school students, which may provide evidence for promoting science popularization on nuclear and radiation. Methods: Questionnaire-based survey was conducted in Beijing high school students, randomized cluster sampling was used to recruit study participants. Demographic information was collected, and cognition level on nuclear and radiation was evaluated by questionnaire. Results: A total of 1029 pieces of eligible questionnaires were collected. The correct rate for answering common sense about nuclear and radiation was 58%, with score of boys significantly higher than that of girls (t = 4.131, P < 0.05). About subjective cognition of nuclear and radiation knowledge, 87 (8.5%) indicated 'quite clear', 779 (75.7%) indicated 'know a little', 163 (15.8%) indicated 'know nothing'. There was significant difference in score of common sense about nuclear and radiation among people with various subjective cognition level of nuclear and radiation (J-T = 8.279, P < 0.05). There was a linear correlation between support degree for nuclear power and subjective cognition level of nuclear and radiation (r = 0.161, P < 0.05). There was significant difference in score of common sense about nuclear and radiation among people with various support degree for nuclear power (J-T = 7.508, P < 0.05), whereas those who had got high scores tended to support nuclear power to a higher degree. Conclutions: Students knew little about knowledge on nuclear and radiation. It is necessary to strengthen propaganda and education on nuclear and radiation, which may help enhance the students' comprehensive quality, and sustainable expansion of nuclear power more support in the long run. (authors)

  7. 30 CFR 75.1703 - Portable electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...

  8. 5 CFR 870.1205 - Electing portability for Option B.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Electing portability for Option B. 870... portability for Option B. (a) The employing agency must notify the employee/assignee(s) of the loss of coverage and the right to elect portability for Option B either before or immediately after the event...

  9. Patients Undergoing Radiation Therapy Are at Risk of Financial Toxicity: A Patient-based Prospective Survey Study.

    Science.gov (United States)

    Palmer, Joshua D; Patel, Tejash T; Eldredge-Hindy, Harriet; Keith, Scott W; Patel, Tapas; Malatesta, Theresa; DiNome, Jessie; Lowther, Anne; Ferguson, Linda; Wagenborg, Sally; Smyles, John; Babaria, Usha; Stabile, Richard; Gressen, Eric; Rudoler, Shari; Fisher, Scot A

    2018-06-01

    Little is known about the financial burden experienced by patients receiving radiation therapy. Furthermore, currently, no financial toxicity screening tools have been validated for use in radiation oncology. Physician surveys were used to gauge provider understanding of treatment costs and their willingness to adopt the use of financial toxicity screening tools. Post-treatment patient surveys were used to investigate the covariates of treatment-induced financial risk. Of the 210 radiation oncologists who completed our survey, 53% reported being "very concerned" with treatment-related costs negatively affecting their patients, and 80% believed that a financial toxicity screening tool would be useful in practice. An analysis of patient surveys using logistic regression found age and cancer site to be the most important variables associated with financial toxicity. Thirty-four patients (22%) experienced financial toxicity related to treatment. The financial toxicities experienced were loss of job (28%), loss of income (24%), difficulty paying their rent or mortgage (20%), difficulty paying for transportation (15%), and difficulty paying for meals (13%). Financial toxicity is an important measure for patients and providers and is experienced by approximately one quarter of patients. Further studies to improve models to predict financial toxicity and how financial toxicity is related to patient outcomes and quality of life are warranted. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  11. Portable double-sided pulsed laser heating system for time-resolved geoscience and materials science applications.

    Science.gov (United States)

    Aprilis, G; Strohm, C; Kupenko, I; Linhardt, S; Laskin, A; Vasiukov, D M; Cerantola, V; Koemets, E G; McCammon, C; Kurnosov, A; Chumakov, A I; Rüffer, R; Dubrovinskaia, N; Dubrovinsky, L

    2017-08-01

    A portable double-sided pulsed laser heating system for diamond anvil cells has been developed that is able to stably produce laser pulses as short as a few microseconds with repetition frequencies up to 100 kHz. In situ temperature determination is possible by collecting and fitting the thermal radiation spectrum for a specific wavelength range (particularly, between 650 nm and 850 nm) to the Planck radiation function. Surface temperature information can also be time-resolved by using a gated detector that is synchronized with the laser pulse modulation and space-resolved with the implementation of a multi-point thermal radiation collection technique. The system can be easily coupled with equipment at synchrotron facilities, particularly for nuclear resonance spectroscopy experiments. Examples of applications include investigations of high-pressure high-temperature behavior of iron oxides, both in house and at the European Synchrotron Radiation Facility using the synchrotron Mössbauer source and nuclear inelastic scattering.

  12. Special report: results of the 2000-2002 association of residents in radiation oncology (arro) surveys

    International Nuclear Information System (INIS)

    Jagsi, Reshma; Chronowski, Gregory M.; Buck, David A.; Kang, Song; Palermo, James

    2004-01-01

    Between 2000 and 2002, the Association of Residents in Radiation Oncology (ARRO) conducted its 18th, 19th, and 20th annual surveys of all residents training in radiation oncology in the United States. This report summarizes these results. The demographic characteristics of residents in training between 2000 and 2002 are detailed, as are issues regarding the quality of training and career choices of residents entering practice

  13. Freely oriented portable superconducting magnet

    Science.gov (United States)

    Schmierer, Eric N [Los Alamos, NM; Prenger, F Coyne [Los Alamos, NM; Hill, Dallas D [Los Alamos, NM

    2010-01-12

    A freely oriented portable superconducting magnet is disclosed. Coolant is supplied to the superconducting magnet from a repository separate from the magnet, enabling portability of the magnet. A plurality of support assemblies structurally anchor and thermally isolate the magnet within a thermal shield. A plurality of support assemblies structurally anchor and thermally isolate the thermal shield within a vacuum vessel. The support assemblies restrain movement of the magnet resulting from energizing and cooldown, as well as from changes in orientation, enabling the magnet to be freely orientable.

  14. Radiation and environmental data analysis computer (REDAC) hardware, software band analysis procedures

    International Nuclear Information System (INIS)

    Hendricks, T.J.

    1985-01-01

    The REDAC was conceived originally as a tape verifier for the Radiation and Environmental Data Acquisition Recorder (REDAR). From that simple beginning in 1971, the REDAC has evolved into a family of systems used for complete analysis of data obtained by the REDAR and other acquisition systems. Portable or mobile REDACs are deployed to support checkout and analysis tasks in the field. Laboratory systems are additionally used for software development, physics investigations, data base management and graphics. System configurations range from man-portable systems to a large laboratory-based system which supports time-shared analysis and development tasks. Custom operating software allows the analyst to process data either interactively or by batch procedures. Analysis packages are provided for numerous necessary functions. All these analysis procedures can be performed even on the smallest man-portable REDAC. Examples of the multi-isotope stripping and radiation isopleth mapping are presented. Techniques utilized for these operations are also presented

  15. Radiation Protection in Pediatric Radiology: Results of a Survey Among Dutch Hospitals.

    Science.gov (United States)

    Bijwaard, Harmen; Valk, Doreth; de Waard-Schalkx, Ischa

    2016-10-01

    A survey about radiation protection in pediatric radiology was conducted among 22 general and seven children's hospitals in the Netherlands. Questions concerned, for example, child protocols used for CT, fluoroscopy and x-ray imaging, number of images and scans made, radiation doses and measures taken to reduce these, special tools used for children, and quality assurance issues. The answers received from 27 hospitals indicate that radiation protection practices differ considerably between general and children's hospitals but also between the respective general and children's hospitals. It is recommended that hospitals consult each other to come up with more uniform best practices. Few hospitals were able to supply doses that can be compared to the national Diagnostic Reference Levels (DRLs). The ones that could be compared exceeded the DRLs in one in five cases, which is more than was expected beforehand.

  16. 24 CFR 982.636 - Homeownership option: Portability.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Homeownership option: Portability... Types Homeownership Option § 982.636 Homeownership option: Portability. (a) General. A family may... described in §§ 982.353 and 982.355 apply to the homeownership option and the administrative...

  17. Radiation and Radon Survey of Akchatau (Khazakstan) and Experience with Radon Remedial Measures

    International Nuclear Information System (INIS)

    Soroka, Y.; Molchanov, A.

    1998-01-01

    A radiation survey of the territory of Akchatau settlement has been carried out. The main factors affecting the high content of radon in dwelling houses were revealed. The experiment on isolation of under floor spaces was carried out to prevent the entry of radon-containing soil gas into living rooms. The repair works efficiency for decreasing of the radon content in hazardous houses was analysed. The survey showed a need for regulation of the value of 222 Rn exhalation on the territories planned for construction works. (author)

  18. Detectors for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Mendez, V.

    1979-09-01

    For our purposes in this review, we note the following points: (1) for charged particle detection, these counters can be filled with any noble gas-quenching gas mixture that produces satisfactory electrical signals; (2) neutron counters, in which the neutrons are detected by their interaction with the specific filling of the chamber to yield an ionizing particle, require special gas mixtures containing /sup 3/He or BF/sub 3/, an alternative approach is to coat the inner surface of the cathode with a boron or lithium compound; (3) proportional counters are used if there is any need to discriminate between different types of radiation incident on the chamber by the magnitude of the ionizing energy retained within the sensitive volume of the counter; (4) proportional counters can operate at higher speeds than Geiger counters, typically up to 10/sup 7/ cts/sec versus less than 10/sup 5//sec for the Geiger counters; and (5) Geiger counters produce very large uniform pulses which can be scaled by very simple electronics, hence, they are often used in survey meters and other portable monitoring instruments.

  19. A national-wide survey of radon and gamma radiation levels in Australian homes

    International Nuclear Information System (INIS)

    Langaroo, M.K.; Wise, K.N.; Duggleby, J.K.; Kotler, L.H.

    1990-04-01

    A nation-wide survey of Australian homes has been conducted to determine the average annual doses to the Australian population from exposure to radon and gamma radiation. The exposure to radon was measured using solid state track detectors (SSTD) whilst the gamma radiation dose was concurrently determined using thermoluminescent dosimetry. Dosemeters were placed in approximately 3400 randomly distributed homes (representing about 1 in 1400 occupied dwellings) for twelve months. The measured annual average radon concentration in Australian homes is 12 Bq m -3 . Using appropriate conversion factors, the annual average effective dose equivalents to the Australian population were determined to be 0.6 mSv and 0.9 mSv for radon and gamma radiation respectively. 20 refs., 3 tabs., 7 figs

  20. ALARA and paediatric imaging in radiation therapy: A survey of Canadian paediatric imaging practice

    International Nuclear Information System (INIS)

    Rodgerson, Christine

    2014-01-01

    Purpose: There is little discussion in the literature regarding paediatric imaging dose reduction with respect to conventional imaging carried out in radiotherapy departments. This is in contrast to diagnostic radiography where dose optimization when imaging children is a very current topic. For this reason Canadian radiotherapy clinics were surveyed to look at paediatric imaging practice, knowledge and perspectives with respect to imaging dose reduction. Method: As this was an exploratory study, a questionnaire was developed and sent to radiation therapy clinics across Canada, via email, to assess knowledge of paediatric imaging and dose reduction initiatives. The questionnaire focus was CT simulation and treatment verification imaging of children. Results: Practice and knowledge of paediatric imaging varied across Canada. Forty percent of clinics reported using paediatric specific protocols for CT simulation and 20% of clinics reported using paediatric specific protocols for treatment verification imaging. There was variation in imaging practices among the clinics that reported treating the most children. The survey results show that while some measures are being taken to reduce paediatric imaging dose in radiation therapy, 46.7% of the respondents felt more could be done. Conclusion: The survey demonstrates interest in dose reduction in radiation therapy imaging as well as differences in current practice and knowledge across Canada. Paediatric imaging dose reduction would appear to be an area of practice that would benefit from more study and development of standards of practice

  1. The Integrated Radiation Mapper Assistant

    Energy Technology Data Exchange (ETDEWEB)

    Carlton, R.E.; Tripp, L.R. [Odetics, Inc., Anaheim, CA (United States)

    1995-03-01

    The Integrated Radiation Mapper Assistant (IRMA) system combines state-of-the-art radiation sensors and microprocessor based analysis techniques to perform radiation surveys. Control of the survey function is from a control station located outside the radiation thus reducing time spent in radiation areas performing radiation surveys. The system consists of a directional radiation sensor, a laser range finder, two area radiation sensors, and a video camera mounted on a pan and tilt platform. THis sensor package is deployable on a remotely operated vehicle. The outputs of the system are radiation intensity maps identifying both radiation source intensities and radiation levels throughout the room being surveyed. After completion of the survey, the data can be removed from the control station computer for further analysis or archiving.

  2. New conceptual design of portable bamboo bridge for emergency purposes

    Science.gov (United States)

    Musthaffa, A. A.; Nor, N. M.; Yusof, M. A.; Yuhazri, M. Y.

    2018-02-01

    Portable bridges serve as routes for troops during the military operations and the disaster relief operation. Nowadays, bamboo has been regarded as one of the alternative construction materials for building and bridge structures. This paper presents the conceptual design of the portable bridge. Several types of portable bridges and bamboo bridges are reviewed in the current work. The characteristics, capability and method of construction of each bridge are discussed. Finally, the conceptual of the portable bamboo bridge for emergency purposes is presented. The idea of producing portable bridge is proposed in the current work as it is crucial for providing route for communities affected by natural disasters.

  3. Data survey about radiation protection and safety of radiation sources in research laboratories

    International Nuclear Information System (INIS)

    Paura, Clayton L.; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2005-01-01

    In Brazil, different types of research using unsealed sources are developed with a variety of radioisotopes. In such activities, professionals and students involved are potentially exposed to internal contamination by 14 C, 45 Ca, 51 Cr, 3 H, 125 I, 32 P, 33 P, 35 S, 90 Sr and 99m Tc. The general objective of this work is to evaluate radiological risks associated to these practices in order to supply information for planning actions aimed to improve radiation protection conditions in research laboratories. The criteria for risk evaluation and the safety aspects adopted in this work were based on CNEN Regulation 6.02 and in IAEA and NRPB publications. The survey of data was carried out during visits to laboratories in public Universities located in the city of Rio de Janeiro where unsealed radioactive sources are used in biochemistry, biophysics and genetic studies. According to the criteria adopted in this work, some practices developed in the laboratories require evaluation of risk of internal contamination depending on the conditions of source manipulation. It was verified the need for training of users of radioactive materials in this type of laboratory. This can be facilitated by the use of basic guides for the classification of areas, radiation protection, safety and source security in research laboratories. It was also observed the need for optimization of such practices in order to minimize the contact with sources. It is recommended to implement more effective source and access controls as a way to reduce risks of individual radiation exposure and loss of radioactive materials (author)

  4. Cloud portability and interoperability issues and current trends

    CERN Document Server

    Di Martino, Beniamino; Esposito, Antonio

    2015-01-01

    This book offers readers a quick, comprehensive and up-to-date overview of the most important methodologies, technologies, APIs and standards related to the portability and interoperability of cloud applications and services, illustrated by a number of use cases representing a variety of interoperability and portability scenarios. The lack of portability and interoperability between cloud platforms at different service levels is the main issue affecting cloud-based services today. The brokering, negotiation, management, monitoring and reconfiguration of cloud resources are challenging tasks

  5. 29 CFR 1910.25 - Portable wood ladders.

    Science.gov (United States)

    2010-07-01

    ... for the construction, care, and use of the common types of portable wood ladders, in order to insure... density wood shall not be used. (ii) [Reserved] (2) [Reserved] (c) Construction requirements. (1... 29 Labor 5 2010-07-01 2010-07-01 false Portable wood ladders. 1910.25 Section 1910.25 Labor...

  6. Rapid monitoring of gaseous fission products in BWRs using a portable spectrometer

    International Nuclear Information System (INIS)

    Yeh, Wei-Wen; Lee, Cheng-Jong; Chen, Chen-Yi; Chung, Chien

    1996-01-01

    Rapid, quantitative determination of gaseous radionuclides is the most difficult task in the field of environmental monitoring for radiation. Although the identification of each gaseous radionuclide is relatively straightforward using its decayed gamma ray as an index, the quantitative measurement is hampered by the time-consuming sample collection procedures, in particular for the radioactive noble gaseous fission products of krypton and xenon. In this work, a field gamma-ray spectrometer consisting of a high-purity germanium detector, portable multichannel anlayzer, and a notebook computer was used to conduct rapid scanning of radioactive krypton and xenon in the air around a nuclear facility

  7. Japanese structure survey of radiation oncology in 2007 with special reference to designated cancer care hospitals

    International Nuclear Information System (INIS)

    Numasaki, Hodaka; Shibuya, Hitoshi; Nishio, Masamichi

    2011-01-01

    Background and Purpose: The structure of radiation oncology in designated cancer care hospitals in Japan was investigated in terms of equipment, personnel, patient load, and geographic distribution. The effect of changes in the health care policy in Japan on radiotherapy structure was also examined. Material and Methods: The Japanese Society of Therapeutic Radiology and Oncology surveyed the national structure of radiation oncology in 2007. The structures of 349 designated cancer care hospitals and 372 other radiotherapy facilities were compared. Results: Respective findings for equipment and personnel at designated cancer care hospitals and other facilities included the following: linear accelerators/facility: 1.3 and 1.0; annual patients/linear accelerator: 296.5 and 175.0; and annual patient load/full-time equivalent radiation oncologist was 237.0 and 273.3, respectively. Geographically, the number of designated cancer care hospitals was associated with population size. Conclusion: The structure of radiation oncology in Japan in terms of equipment, especially for designated cancer care hospitals, was as mature as that in European countries and the United States, even though the medical costs in relation to GDP in Japan are lower. There is still a shortage of manpower. The survey data proved to be important to fully understand the radiation oncology medical care system in Japan. (orig.)

  8. Radiation dosage to the breast in well-women screening surveys

    Energy Technology Data Exchange (ETDEWEB)

    Asbury, D L; Barker, P G [University Hospital of South Manchester (UK)

    1975-12-01

    The D.H.S.S. is supporting research in several centres to determine the feasibility of establishing a nationwide Breast Cancer Screening Programme. This paper answers the questions 'What is the radiation dose produced by mammography, and is it safe'. In the context of well-women screening surveys a maximum skin dose of 2 R has been recommended. The variation of dose across the breast surface is recorded and the reasons for this enumerated. The lowest mean dose recorded with industrial quality film was 4.9 R, so that such fine-grain film cannot be used for this purpose. Doses within the recommended safety limit are achieved by the use of vacuum-packed film-screen combinations. The new rare-earth phosphor screens produced the lowest dose (0.2 R). There was no significant gonad dose. It is concluded that mammographic examination of well-women can be performed at safe radiation levels.

  9. Portable FAIMS: Applications and Future Perspectives.

    Science.gov (United States)

    Costanzo, Michael T; Boock, Jared J; Kemperman, Robin H J; Wei, Michael S; Beekman, Christopher R; Yost, Richard A

    2017-11-01

    Miniaturized mass spectrometry (MMS) is optimal for a wide variety of applications that benefit from field-portable instrumentation. Like MMS, field asymmetric ion mobility spectrometry (FAIMS) has proven capable of providing in situ analysis, allowing researchers to bring the lab to the sample. FAIMS compliments MMS very well, but has the added benefit of operating at atmospheric pressure, unlike MS. This distinct advantage makes FAIMS uniquely suited for portability. Since its inception, FAIMS has been envisioned as a field-portable device, as it affords less expense and greater simplicity than many similar methods. Ideally, these are simple, robust devices that may be operated by non-professional personnel, yet still provide adequate data when in the field. While reducing the size and complexity tends to bring with it a loss of performance and accuracy, this is made up for by the incredibly high throughput and overall convenience of the instrument. Moreover, the FAIMS device used in the field can be brought back to the lab, and coupled to a conventional mass spectrometer to provide any necessary method development and compound validation. This work discusses the various considerations, uses, and applications for portable FAIMS instrumentation, and how the future of each applicable field may benefit from the development and acceptance of such a device.

  10. 14 CFR 91.21 - Portable electronic devices.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  11. A portable organic plastic scintillator dosimetry system for low energy X-rays: a feasibility study using an intraoperative X-ray unit as the radiation source

    International Nuclear Information System (INIS)

    Williams, Kerry; Robinson, Neil; Trapp, Jamie; Geso, Moshi; Ackerly, Trevor; Das, Ram; Kemp, Penny

    2007-01-01

    The effective use of near water equivalent organic plastic scintillators (OPS) for radiation dosimetry with high-energy sources under laboratory conditions is recognized. In this work, an OPS-based dosimeter using a photodiode combined with improved solid state detection and signal processing techniques has been developed; it offers the potential for the construction of a stable and fully portable dosimeter which will extend the useful range of measurement beyond the usual MeV area and provide reliable readings down to sub-100 keV X-ray energy levels. In these experiments, the instrument described has been used for the dosimetry of INTRABEAM intraoperative radiotherapy (IORT) equipment at distances as low as 1.8 mm from the effective source, i.e., 0.2 mm from the X-ray probe surface. Comparison is shown with dosimetry measurements made using the calibrated reference ion chamber supplied by the IORT equipment manufacturer. (author)

  12. Portability of Technical Skills Across Occupations

    OpenAIRE

    Mukuni, Joseph Siloka

    2012-01-01

    In the literature, much has been reported about skill shortages in the labor market and many solutions have been suggested but most of them do not appear to work well for developing countries. This study investigated the place of portable technical skills as an option for addressing skill shortages, particularly in developing countries. The objective of the study was to determine whether different occupations have portable technical skills, which graduates of workforce development programs ca...

  13. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  14. Geophex airborne unmanned survey system

    Energy Technology Data Exchange (ETDEWEB)

    Won, I.J.; Taylor, D.W.A.

    1995-03-01

    The purpose of this effort is to design, construct, and evaluate a portable, remotely-piloted, airborne, geophysical survey system. This nonintrusive system will provide {open_quotes}stand-off{close_quotes} capability to conduct surveys and detect buried objects, structures, and conditions of interest at hazardous locations. This system permits two operators to rapidly conduct geophysical characterization of hazardous environmental sites. During a survey, the operators remain remote from, but within visual distance, of, the site. The sensor system never contacts the Earth, but can be positioned near the ground so that weak anomalies can be detected.

  15. Portability of supplementary pension rights in Europe

    DEFF Research Database (Denmark)

    Guardiancich, Igor

    2015-01-01

    In its effort to guarantee the free movement of workers, the European Union devised an advanced system of coordination of social security rights. Since 1958, statutory pensions are being aggregated for workers moving across the Member States. However, until mid-2014, the portability of supplement......In its effort to guarantee the free movement of workers, the European Union devised an advanced system of coordination of social security rights. Since 1958, statutory pensions are being aggregated for workers moving across the Member States. However, until mid-2014, the portability...... of supplementary pension rights was not assured, there by undermining the freedom to labor mobility. This impaired the efficient allocation of labor, prevented sound family planning, infringed the fundamental right to social protection and during the Great Recession, hindered the employability of workers across......, as opposed to the coordination of statutory ones, has been neglected and contested for a long time. Second, it illustrates the shortcomings of a patchy coordination- without-portability regime. Third, it enumerates the characteristics of the Portability Directive passed by the European Parliament in April...

  16. Current technological clinical practice in breast radiotherapy; results of a survey in EORTC-Radiation Oncology Group affiliated institutions

    NARCIS (Netherlands)

    van der Laan, Hans Paul; Hurkmans, Coen W; Kuten, Abraham; Westenberg, Helen A

    PURPOSE: To evaluate the current technological clinical practice of radiation therapy of the breast in institutions participating in the EORTC-Radiation Oncology Group (EORTC-ROG). MATERIALS AND METHODS: A survey was conducted between August 2008 and January 2009 on behalf of the Breast Working

  17. Coordination of Breast Cancer Care Between Radiation Oncologists and Surgeons: A Survey Study

    International Nuclear Information System (INIS)

    Jagsi, Reshma; Abrahamse, Paul; Morrow, Monica; Hamilton, Ann S.; Graff, John J.; Katz, Steven J.

    2012-01-01

    Purpose: To assess whether radiation oncologists and surgeons differ in their attitudes regarding the local management of breast cancer, and to examine coordination of care between these specialists. Methods and Materials: We surveyed attending surgeons and radiation oncologists who treated a population-based sample of patients diagnosed with breast cancer in metropolitan Detroit and Los Angeles. We identified 419 surgeons, of whom 318 (76%) responded, and 160 radiation oncologists, of whom 117 (73%) responded. We assessed demographic, professional, and practice characteristics; challenges to coordinated care; and attitudes toward management in three scenarios. Results: 92.1% of surgeons and 94.8% of radiation oncologists indicated access to a multidisciplinary tumor board. Nevertheless, the most commonly identified challenge to radiation oncologists, cited by 27.9%, was failure of other providers to include them in the treatment decision process early enough. Nearly half the surgeons (49.7%) stated that few or almost none of the breast cancer patients they saw in the past 12 months had consulted with a radiation oncologist before undergoing definitive surgery. Surgeons and radiation oncologists differed in their recommendations in management scenarios. Radiation oncologists were more likely to favor radiation than were surgeons for a patient with 3/20 lymph nodes undergoing mastectomy (p = 0.03); surgeons were more likely to favor more widely clear margins after breast conservation than were radiation oncologists (p = 0.001). Conclusions: Despite the widespread availability of tumor boards, a substantial minority of radiation oncologists indicated other providers failed to include them in the breast cancer treatment decision-making process early enough. Earlier inclusion of radiation oncologists may influence patient decisions, and interventions to facilitate this should be considered.

  18. Coordination of Breast Cancer Care Between Radiation Oncologists and Surgeons: A Survey Study

    Energy Technology Data Exchange (ETDEWEB)

    Jagsi, Reshma, E-mail: rjagsi@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Abrahamse, Paul [Department of Internal Medicine, University of Michigan, Ann Arbor, MI (United States); Morrow, Monica [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Hamilton, Ann S. [Keck School of Medicine, University of Southern California/Norris Comprehensive Cancer Center, Los Angeles, CA (United States); Graff, John J. [Department of Radiation Oncology, Cancer Institute of New Jersey, Robert Wood Johnson Medical School, New Brunswick, NJ (United States); Katz, Steven J. [Department of Internal Medicine, Division of General Medicine and Department of Health Management and Policy, School of Public Health, University of Michigan Health System, Ann Arbor, MI (United States)

    2012-04-01

    Purpose: To assess whether radiation oncologists and surgeons differ in their attitudes regarding the local management of breast cancer, and to examine coordination of care between these specialists. Methods and Materials: We surveyed attending surgeons and radiation oncologists who treated a population-based sample of patients diagnosed with breast cancer in metropolitan Detroit and Los Angeles. We identified 419 surgeons, of whom 318 (76%) responded, and 160 radiation oncologists, of whom 117 (73%) responded. We assessed demographic, professional, and practice characteristics; challenges to coordinated care; and attitudes toward management in three scenarios. Results: 92.1% of surgeons and 94.8% of radiation oncologists indicated access to a multidisciplinary tumor board. Nevertheless, the most commonly identified challenge to radiation oncologists, cited by 27.9%, was failure of other providers to include them in the treatment decision process early enough. Nearly half the surgeons (49.7%) stated that few or almost none of the breast cancer patients they saw in the past 12 months had consulted with a radiation oncologist before undergoing definitive surgery. Surgeons and radiation oncologists differed in their recommendations in management scenarios. Radiation oncologists were more likely to favor radiation than were surgeons for a patient with 3/20 lymph nodes undergoing mastectomy (p = 0.03); surgeons were more likely to favor more widely clear margins after breast conservation than were radiation oncologists (p = 0.001). Conclusions: Despite the widespread availability of tumor boards, a substantial minority of radiation oncologists indicated other providers failed to include them in the breast cancer treatment decision-making process early enough. Earlier inclusion of radiation oncologists may influence patient decisions, and interventions to facilitate this should be considered.

  19. Ultra-portable field transfer radiometer for vicarious calibration of earth imaging sensors

    Science.gov (United States)

    Thome, Kurtis; Wenny, Brian; Anderson, Nikolaus; McCorkel, Joel; Czapla-Myers, Jeffrey; Biggar, Stuart

    2018-06-01

    A small portable transfer radiometer has been developed as part of an effort to ensure the quality of upwelling radiance from test sites used for vicarious calibration in the solar reflective. The test sites are used to predict top-of-atmosphere reflectance relying on ground-based measurements of the atmosphere and surface. The portable transfer radiometer is designed for one-person operation for on-site field calibration of instrumentation used to determine ground-leaving radiance. The current work describes the detector- and source-based radiometric calibration of the transfer radiometer highlighting the expected accuracy and SI-traceability. The results indicate differences between the detector-based and source-based results greater than the combined uncertainties of the approaches. Results from recent field deployments of the transfer radiometer using a solar radiation based calibration agree with the source-based laboratory calibration within the combined uncertainties of the methods. The detector-based results show a significant difference to the solar-based calibration. The source-based calibration is used as the basis for a radiance-based calibration of the Landsat-8 Operational Land Imager that agrees with the OLI calibration to within the uncertainties of the methods.

  20. Community Surveys: Low Dose Radiation. Fernald, Ohio and Rocky Flats, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    C. K. Mertz; James Flynn; Donald G. MacGregor; Theresa Satterfield; Stephen M. Johnson; Seth Tuler; Thomas Webler

    2002-10-16

    This report is intended to present a basic description of the data from the two community surveys and to document the text of the questions; the methods used for the survey data collection; and a brief overview of the results. Completed surveys were conducted at local communities near the Rocky Flats, Colorado and the Fernald, Ohio sites; no survey was conducted for the Brookhaven, New York site. Fernald. The Fernald sample was randomly selected from 98% of all potential residential telephones in the townships of Ross, Morgan, and Crosby. The only telephone exchanges not used for the Fernald study had 4%, or fewer, of the holders of the telephone numbers actually living in either of the three target townships. Surveying started on July 24, 2001 and finished on August 30, 2001. A total of 399 completed interviews were obtained resulting in a CASRO response rate of 41.8%. The average length of an interview was 16.5 minutes. Rocky Flats. The sample was randomly selected from all potential residential telephones in Arvada and from 99% of the potential telephones in Westminster. Surveying started on August 10, 2001 and finished on September 25, 2001. A total of 401 completed interviews were obtained with a CASRO response rate of 32.5%. The average length of an interview was 15.7 minutes. Overall, respondents hold favorable views of science. They indicate an interest in developments in science and technology, feel that the world is better off because of science, and that science makes our lives healthier, easier, and more comfortable. However, respondents are divided on whether science should decide what is safe or not safe for themselves and their families. The majority of the respondents think that standards for exposure to radiation should be based on what science knows about health effects of radiation and on what is possible with today's technology. Although few respondents had visited the sites, most had heard or read something about Fernald or Rocky Flat s in

  1. Community Surveys: Low Dose Radiation. Fernald, Ohio and Rocky Flats, Colorado

    International Nuclear Information System (INIS)

    C. K. Mertz; James Flynn; Donald G. MacGregor; Theresa Satterfield; Stephen M. Johnson; Seth Tuler; Thomas Webler email ckmertz@decisionresearch.org

    2002-01-01

    This report is intended to present a basic description of the data from the two community surveys and to document the text of the questions; the methods used for the survey data collection; and a brief overview of the results. Completed surveys were conducted at local communities near the Rocky Flats, Colorado and the Fernald, Ohio sites; no survey was conducted for the Brookhaven, New York site. Fernald. The Fernald sample was randomly selected from 98% of all potential residential telephones in the townships of Ross, Morgan, and Crosby. The only telephone exchanges not used for the Fernald study had 4%, or fewer, of the holders of the telephone numbers actually living in either of the three target townships. Surveying started on July 24, 2001 and finished on August 30, 2001. A total of 399 completed interviews were obtained resulting in a CASRO response rate of 41.8%. The average length of an interview was 16.5 minutes. Rocky Flats. The sample was randomly selected from all potential residential telephones in Arvada and from 99% of the potential telephones in Westminster. Surveying started on August 10, 2001 and finished on September 25, 2001. A total of 401 completed interviews were obtained with a CASRO response rate of 32.5%. The average length of an interview was 15.7 minutes. Overall, respondents hold favorable views of science. They indicate an interest in developments in science and technology, feel that the world is better off because of science, and that science makes our lives healthier, easier, and more comfortable. However, respondents are divided on whether science should decide what is safe or not safe for themselves and their families. The majority of the respondents think that standards for exposure to radiation should be based on what science knows about health effects of radiation and on what is possible with today's technology. Although few respondents had visited the sites, most had heard or read something about Fernald or Rocky Flat s in the

  2. Use of portable X-ray fluorescence instrument for bulk alloy analysis on low corroded indoor bronzes

    International Nuclear Information System (INIS)

    Šatović, D.; Desnica, V.; Fazinić, S.

    2013-01-01

    One of the most often used non-destructive methods for elemental analysis when performing field measurements on bronze sculptures is X-ray fluorescence (XRF) analysis based on portable instrumentation. However, when performing routine in-situ XRF analysis on corroded objects obtained results are sometimes considerably influenced by the corrosion surface products. In this work the suitability of portable XRF for bulk analysis of low corroded bronzes, which were initially precisely characterized using sophisticated and reliable laboratory methods, was investigated and some improvements in measuring technique and data processing were given. Artificially corroded bronze samples were analyzed by a portable XRF instrument using the same methodology and procedures as when performing in-situ analysis on real objects. The samples were first investigated using sophisticated complementary laboratory techniques: Scanning Electron Microscopy, Proton-Induced X-ray Emission Spectroscopy and Rutherford Backscattering Spectrometry, in order to gain precise information on the formation of the corrosion product layers and in-depth elemental profile of corrosion layers for different aging parameters. It has been shown that for corrosion layers of up to ca. 25 μm a portable XRF can yield very accurate quantification results. - Highlights: • XRF quantification is very accurate for bronze corrosion layers of up to ca. 25 μm. • Corrosion layer formation on bronze described in two phases. • Corrosion layers precisely characterized using PIXE, RBS and SEM. • Corrosion approximated as CuO for layer thickness calculations via X-ray attenuations • Increasingly lighter corrosion matrix may cause SnLα radiation intensity inversion

  3. Use of portable X-ray fluorescence instrument for bulk alloy analysis on low corroded indoor bronzes

    Energy Technology Data Exchange (ETDEWEB)

    Šatović, D., E-mail: dsatovic@alu.hr [Department of Conservation and Restoration, Academy of Fine Arts, Ilica 85, 10000 Zagreb (Croatia); Desnica, V. [Department of Conservation and Restoration, Academy of Fine Arts, Ilica 85, 10000 Zagreb (Croatia); Fazinić, S. [Laboratory for Ion Beam Interactions, Ruđer Bošković Institute, Bijenička 54, 10000 Zagreb (Croatia)

    2013-11-01

    One of the most often used non-destructive methods for elemental analysis when performing field measurements on bronze sculptures is X-ray fluorescence (XRF) analysis based on portable instrumentation. However, when performing routine in-situ XRF analysis on corroded objects obtained results are sometimes considerably influenced by the corrosion surface products. In this work the suitability of portable XRF for bulk analysis of low corroded bronzes, which were initially precisely characterized using sophisticated and reliable laboratory methods, was investigated and some improvements in measuring technique and data processing were given. Artificially corroded bronze samples were analyzed by a portable XRF instrument using the same methodology and procedures as when performing in-situ analysis on real objects. The samples were first investigated using sophisticated complementary laboratory techniques: Scanning Electron Microscopy, Proton-Induced X-ray Emission Spectroscopy and Rutherford Backscattering Spectrometry, in order to gain precise information on the formation of the corrosion product layers and in-depth elemental profile of corrosion layers for different aging parameters. It has been shown that for corrosion layers of up to ca. 25 μm a portable XRF can yield very accurate quantification results. - Highlights: • XRF quantification is very accurate for bronze corrosion layers of up to ca. 25 μm. • Corrosion layer formation on bronze described in two phases. • Corrosion layers precisely characterized using PIXE, RBS and SEM. • Corrosion approximated as CuO for layer thickness calculations via X-ray attenuations • Increasingly lighter corrosion matrix may cause SnLα radiation intensity inversion.

  4. Radiation exposure during ureteroscopy

    International Nuclear Information System (INIS)

    Bagley, D.H.; Cubler-Goodman, A.

    1990-01-01

    Use of fluoroscopy during ureteroscopy increases the risk of radiation exposure to the urologist and patient. Radiation entrance dosages were measured at skin level in 37 patients, and at the neck, trunk and finger of the urologist, and neck and trunk of the circulating nurse. Radiation exposure time was measured in 79 patients, and was related to the purpose of the procedure and the type of ureteroscope used, whether rigid or flexible. Exposure could be minimized by decreasing the fluoroscopy time. A portable C-arm fluoroscopy unit with electronic imaging and last image hold mode should be used to minimize exposure time. Lead aprons and thyroid shields should be used by the urologist and other personnel in the endoscopy room

  5. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  6. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  7. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  8. Portable bathtub: technology for bed bath in bedridden patients.

    Science.gov (United States)

    Backes, Dirce Stein; Gomes, Carine Alves; Pereira, Simone Barbosa; Teles, Noelucy Ferreira; Backes, Marli Terezinha Stein

    2017-04-01

    determine the benefits of the Portable Bathtub as technology for bed bath in bedridden patients. qualitative research of exploratory-descriptive character, whose data were collected by means of 30 interviews with patients, family members and professionals directly involved in bed bath, carried out with Portable Bathtub, in bedridden patients of a medical clinic, from July to December 2015. from the data encoded by thematic content analysis resulted two categories: Portable Bathtub: from morphine to the patient's rekindled eyes; From mechanized practice to unique, transforming care. we concluded that the Portable Bathtub constitutes enhancing technology, as it enables clinical improvement of the patient's general condition and transcends traditional mechanized practices by the reach of advanced nursing care practices.

  9. Image quality assessment and medical physics evaluation of different portable dental X-ray units.

    Science.gov (United States)

    Pittayapat, Pisha; Oliveira-Santos, Christiano; Thevissen, Patrick; Michielsen, Koen; Bergans, Niki; Willems, Guy; Debruyckere, Deborah; Jacobs, Reinhilde

    2010-09-10

    Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay 60 kVp, Nomad 60 kVp and Rextar 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Statistical analysis showed good quality imaging for all system, with the combination of Nomad and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p1m: Rextar <0.2 microGy, MinRay <0.1 microGy). The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  11. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  12. Radiation monitoring system

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  13. Impact of Burst Buffer Architectures on Application Portability

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States); Oral, H. Sarp [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science; Atchley, Scott [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science; Vazhkudai, Sudharshan S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). National Center for Computational Science

    2016-09-30

    The Oak Ridge and Argonne Leadership Computing Facilities are both receiving new systems under the Collaboration of Oak Ridge, Argonne, and Livermore (CORAL) program. Because they are both part of the INCITE program, applications need to be portable between these two facilities. However, the Summit and Aurora systems will be vastly different architectures, including their I/O subsystems. While both systems will have POSIX-compliant parallel file systems, their Burst Buffer technologies will be different. This difference may pose challenges to application portability between facilities. Application developers need to pay attention to specific burst buffer implementations to maximize code portability.

  14. Portable real time analysis system for regional cerebral blood flow

    International Nuclear Information System (INIS)

    Tiernan, T.; Entine, G.; Stump, D.A.; Prough, D.S.

    1988-01-01

    A very portable, regional cerebral blood flow (rCBF) analysis instrument system suitable for use in the operating theater during surgery is under development. Cadmium telluride (CdTe) solid state radiation detectors, an 8086 based data acquisition and communications module and a DEC Microvax computer are used so that the instrument is very compact, yet has the computational power to provide real time data analysis in the clinical environment. The instrument is currently being used at Bowman Gray School of Medicine to study rCBF during cardiopulmonary bypass surgery (CPB). Preliminary studies indicate that monitoring rCBF during this surgical procedure may provide insights into the mechanism that causes a significant fraction of these patients to suffer post operative neuropsychological deficit

  15. Actual survey of dose evaluation method for standardization of radiation therapy techniques. With special reference to display method of radiation doses

    International Nuclear Information System (INIS)

    Kumagai, Kozo; Yoshiura, Takao; Izumi, Takashi; Araki, Fujio; Takada, Takuo; Jingu, Kenichi.

    1994-01-01

    This report presents the results of questionnaire survey for actual conditions of radiation therapy, which was conducted with the aim of establishing the standardization of radiation therapy techniques. Questionnaires were sent to 100 facilities in Japan, and 86 of these answered, consisting of 62 university hospitals, 2 national hospitals, 14 cancer centers, 4 prefectural or municipal hospitals, and 4 other hospitals. In addition to electron beam therapy, the following typical diseases for radiation therapy were selected as standard irradiation models: cancers of the larynx, esophagus, breast, and uterine cervix, and malignant lymphomas. According to these models, questionnaire results are analyzed in terms of the following four items: (1) irradiation procedures, (2) energy used for radiotherapy, (3) the depth for calculating target absorption doses, and (4) points for displaying target absorption doses. (N.K.)

  16. Portable bathtub: technology for bed bath in bedridden patients

    Directory of Open Access Journals (Sweden)

    Dirce Stein Backes

    Full Text Available ABSTRACT Objective: determine the benefits of the Portable Bathtub as technology for bed bath in bedridden patients. Method: qualitative research of exploratory-descriptive character, whose data were collected by means of 30 interviews with patients, family members and professionals directly involved in bed bath, carried out with Portable Bathtub, in bedridden patients of a medical clinic, from July to December 2015. Results: from the data encoded by thematic content analysis resulted two categories: Portable Bathtub: from morphine to the patient's rekindled eyes; From mechanized practice to unique, transforming care. Conclusion: we concluded that the Portable Bathtub constitutes enhancing technology, as it enables clinical improvement of the patient's general condition and transcends traditional mechanized practices by the reach of advanced nursing care practices.

  17. Ear diseases among secondary school students in Xi'an, China: The role of portable audio device use, insomnia and academic stress

    Directory of Open Access Journals (Sweden)

    He Ya

    2011-06-01

    Full Text Available Abstract Background Hearing impairment negatively impacts students' development of academic, language and social skills. Even minimal unilateral hearing loss can hinder educational performance. We investigated the prevalence of ear diseases among secondary school students in the city of Xi'an, China in order to provide a foundation for evidence-based hearing healthcare. Methods A stratified random sampling survey was conducted in 29 secondary schools. Demographics and medical histories were collected, and otologic examinations were performed. Questionnaires were administered to assess insomnia, academic stress and use of portable audio devices. Logistic regression analysis was used to identify factors associated with hearing impairment, and the association of sensorineural hearing loss with insomnia, academic stress and the use of portable audio devices was analyzed with the chi-square test. Results The percentage of students with some form of ear disease was 3.32%. External ear disease, middle ear disease and sensorineural hearing loss occurred in 1.21%, 0.64% and 1.47% of the students, respectively. Boys had a relatively higher prevalence of ear disease than girls. According to our survey, the prevalence of sensorineural hearing loss increased significantly among the students with insomnia and extended use of portable audio devices, but not among those with elevated levels of academic stress. Hearing aids and surgical treatment were needed in 1.47% and 0.89% of the students, respectively. Conclusions There is a high prevalence of ear disease among secondary school students, and this should be given more attention. Insomnia and the excessive use of portable audio devices may be related to adolescent sensorineural hearing loss. It is important to establish and comply with an evidence-based preventive strategy.

  18. Orthopedic surgeons’ knowledge regarding risk of radiation exposition: a survey analysis

    Directory of Open Access Journals (Sweden)

    Tunçer Nejat

    2017-01-01

    Full Text Available Introduction: The purpose of this study is to evaluate the knowledge levels of orthopedic surgeons working in Turkey about the uses and possible risks of fluoroscopy and assess methods for preventing radiation damage. Methods: A questionnaire with a total of 12 questions was sent to 1121 orthopedic surgeons working in Turkey. The questionnaire evaluated participants’ knowledge about the uses and risks of fluoroscopy and methods for preventing damage. One thousand and twenty-four orthopedic surgeons were found to be suitable for inclusion in the study. The effects of fluoroscopy on patients were not assessed in our study. Results: The data obtained were statistically evaluated. Of the surveyed surgeons, 313 (30% had used fluoroscopy in over 50% of their operations. The average number of fluoroscopy shots per case was 54.5. A lead apron was the most commonly used (88% protection from the harmful effects of radiation. Fluoroscopy shots were performed with the help of operating room personnel (86%. A dosimeter was used 5% of the time. Conclusion: According to the survey results, the need for fluoroscopy was very high in orthopedic surgery. However, orthopedic surgeons have inadequate knowledge about the uses and risks of fluoroscopy and methods for preventing damage. Therefore, we believe that training on this topic should be provided to all orthopedic surgeons.

  19. Orthopedic surgeons' knowledge regarding risk of radiation exposition: a survey analysis.

    Science.gov (United States)

    Tunçer, Nejat; Kuyucu, Ersin; Sayar, Şafak; Polat, Gökhan; Erdil, İrem; Tuncay, İbrahim

    2017-01-01

    The purpose of this study is to evaluate the knowledge levels of orthopedic surgeons working in Turkey about the uses and possible risks of fluoroscopy and assess methods for preventing radiation damage. A questionnaire with a total of 12 questions was sent to 1121 orthopedic surgeons working in Turkey. The questionnaire evaluated participants' knowledge about the uses and risks of fluoroscopy and methods for preventing damage. One thousand and twenty-four orthopedic surgeons were found to be suitable for inclusion in the study. The effects of fluoroscopy on patients were not assessed in our study. The data obtained were statistically evaluated. Of the surveyed surgeons, 313 (30%) had used fluoroscopy in over 50% of their operations. The average number of fluoroscopy shots per case was 54.5. A lead apron was the most commonly used (88%) protection from the harmful effects of radiation. Fluoroscopy shots were performed with the help of operating room personnel (86%). A dosimeter was used 5% of the time. According to the survey results, the need for fluoroscopy was very high in orthopedic surgery. However, orthopedic surgeons have inadequate knowledge about the uses and risks of fluoroscopy and methods for preventing damage. Therefore, we believe that training on this topic should be provided to all orthopedic surgeons. © The Authors, published by EDP Sciences, 2017.

  20. Portable smartphone based quantitative phase microscope

    Science.gov (United States)

    Meng, Xin; Tian, Xiaolin; Yu, Wei; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2018-01-01

    To realize portable device with high contrast imaging capability, we designed a quantitative phase microscope using transport of intensity equation method based on a smartphone. The whole system employs an objective and an eyepiece as imaging system and a cost-effective LED as illumination source. A 3-D printed cradle is used to align these components. Images of different focal planes are captured by manual focusing, followed by calculation of sample phase via a self-developed Android application. To validate its accuracy, we first tested the device by measuring a random phase plate with known phases, and then red blood cell smear, Pap smear, broad bean epidermis sections and monocot root were also measured to show its performance. Owing to its advantages as accuracy, high-contrast, cost-effective and portability, the portable smartphone based quantitative phase microscope is a promising tool which can be future adopted in remote healthcare and medical diagnosis.

  1. Radiation protection program at an accelerator facility complex

    International Nuclear Information System (INIS)

    Ramanuja, Jaya

    2007-01-01

    Broad aspects of Radiation Protection Program at the Tyco Healthcare/Mallinckrodt Inc. will be presented with emphasis on Occupational dose, Public dose and ALARA program. Regulatory requirements, compliance and radio nuclides of concern for external exposure and internal contamination will be discussed. The facility is subject to in depth annual inspections by the Nuclear Regulatory Commission (NRC) to ensure compliance with regulations and operating license requirements. The facility is required to have an emergency contingency plan in place. A simulated emergency drill scenario is witnessed and graded by the NRC and state inspectors, with full participation by the fire department and the local hospital. Radiation Safety Officer (RSO) is in charge of all radiological aspects of the facility, and reports to the plant manager directly. The RSO or any of his staff has the authority to stop a job if there is a radiological concern. The Radiation protection organization interfaces with Production, QA and Engineering and ensures there is no conflict with Industrial Safety, OSHA and FDA requirements. Any employee has the right to call the regulatory officials if he/she has a concern. Operational aspects of Radiation protection program such as radiological survey, contamination control and limits, air sample survey, radio active waste processing and record retention requirements are per plant procedures and regulatory requirements. Shielding and administrative requirements for designing a modification to an existing design or a new lab/hot cell is subject to in-depth review and approval by Radiation Safety Committee. Each department has a Dose Reduction Subcommittee which meets periodically to discuss if any changes in procedures or facility can be made to decrease the dose. The subcommittee also trends the dose to ensure it is trending downward. Even though 99 Mo/ 99m TC generators are manufactured at the facility, majority of the dose is from cyclotron maintenance

  2. Survey of radiation doses and health effects in medical diagnostic X-ray workers in China

    International Nuclear Information System (INIS)

    Wang Jixian; Zhang Liangan; Liu Jinzhong; Zhang Jingyuan

    1984-01-01

    The results of a nationwide survey of radiation doses and health effects in 26983 medical diagnostic X-ray workers in 28 provinces of China were reported. The control group was composed of 25785 non-X-ray medical workers in the same hospitals where the investigated X-ray workers worked. Of the radiological workers surveyed 75.3% received cumulative radiation doses below 50 mGy, only 2.7% received doses greater than 500 mGy, the average cumulative dose being 45.0 mGy. The average length of service was 11 years. The main radiation effects relating to radiation doses were the increase of frequencies of both chromosomal aberrations and micronuclei in peripheral blood lymphocytes, which were 0.362% and 0.0358% in the irradiated group, and 0.122% and 0.0138% in the control group, respectively. The incidence and mortality rate of leukemias increased significantly in the irradiated group. The incidence and standardized incidence of leukemias were 9.61 . 10 -5 and 9.67 . 10 -5 in the irradiated group and 2.74 . 10 -5 and 2.77 . 10 -5 in the control group. The leukemia mortality rates in the two groups were 8.60 . 10 -5 and 1.24 . 10 -5 respectively, and the standardized mortality rates were 8.60 . 10 -5 and 1.27 . 10 -5 respectively. (Author)

  3. Portable Tablets in Science Museum Learning: Options and Obstacles

    Science.gov (United States)

    Gronemann, Sigurd Trolle

    2017-06-01

    Despite the increasing use of portable tablets in learning, their impact has received little attention in research. In five different projects, this media-ethnographic and design-based analysis of the use of portable tablets as a learning resource in science museums investigates how young people's learning with portable tablets matches the intentions of the museums. By applying media and information literacy (MIL) components as analytical dimensions, a pattern of discrepancies between young people's expectations, their actual learning and the museums' approaches to framing such learning is identified. It is argued that, paradoxically, museums' decisions to innovate by introducing new technologies, such as portable tablets, and new pedagogies to support them conflict with many young people's traditional ideas of museums and learning. The assessment of the implications of museums' integration of portable tablets indicates that in making pedagogical transformations to accommodate new technologies, museums risk opposing didactic intention if pedagogies do not sufficiently attend to young learners' systemic expectations to learning and to their expectations to the digital experience influenced by their leisure use.

  4. Measurement Of I-131 In Air Using A Portable Gamma Spectrometer

    International Nuclear Information System (INIS)

    Bunawas; Dadong Iskandar; Wahyudi; U, Wiwik

    2000-01-01

    Aerosol contamination of I-131, radioactive emitting gamma radiation, can be directly measured by using a portable gamma spectrometer which used GC2020 Canberra HPGe detector. Assuming constant concentration of I-131 in the infinite space of semi spherical, calibration factor, and detection limits determined using standard CH 3 I gas. The results showed that the detection limits for 1 hour counting period was 3.06 Bq/m exp.3 for confidence level of 95% (2σ). Field measurements are conducted on several rooms with uncertainties variation between 0.34 and 60.11% compare with true values. Qualitative discussion of the factors contributing to the uncertainty in the in situ result is included

  5. Portable Weather Applications for General Aviation Pilots.

    Science.gov (United States)

    Ahlstrom, Ulf; Ohneiser, Oliver; Caddigan, Eamon

    2016-09-01

    The objective of this study was to examine the potential benefits and impact on pilot behavior from the use of portable weather applications. Seventy general aviation (GA) pilots participated in the study. Each pilot was randomly assigned to an experimental or a control group and flew a simulated single-engine GA aircraft, initially under visual meteorological conditions (VMC). The experimental group was equipped with a portable weather application during flight. We recorded measures for weather situation awareness (WSA), decision making, cognitive engagement, and distance from the aircraft to hazardous weather. We found positive effects from the use of the portable weather application, with an increased WSA for the experimental group, which resulted in credibly larger route deviations and credibly greater distances to hazardous weather (≥30 dBZ cells) compared with the control group. Nevertheless, both groups flew less than 20 statute miles from hazardous weather cells, thus failing to follow current weather-avoidance guidelines. We also found a credibly higher cognitive engagement (prefrontal oxygenation levels) for the experimental group, possibly reflecting increased flight planning and decision making on the part of the pilots. Overall, the study outcome supports our hypothesis that portable weather displays can be used without degrading pilot performance on safety-related flight tasks, actions, and decisions as measured within the constraints of the present study. However, it also shows that an increased WSA does not automatically translate to enhanced flight behavior. The study outcome contributes to our knowledge of the effect of portable weather applications on pilot behavior and decision making. © 2016, Human Factors and Ergonomics Society.

  6. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  7. Analysis And Simulation Of Low Profile Planar Inverted - F Antenna Design For WLAN Operation In Portable Devices

    Directory of Open Access Journals (Sweden)

    Zaw Htet Lwin

    2015-08-01

    Full Text Available This paper presents a compact planar invertedF antenna PIFA design for WLAN operation in portable devices. The proposed design has size of 8 x 21 mm and provides peak directive gain of 5.78dBi with the peak return loss of -33.89dB and input impedance of 50.28amp8486. It covers a 10dB return loss bandwidth of 410MHz 2.37GHz 2.789GHz. Its VSWR varies from 1.96 to 1.93 within the antenna return loss bandwidth. As the dimension of the proposed antenna is very small the antenna is promising to be embedded within the different portable devices employing WiFi applications. This paper includes the return loss as a function of frequency with varying the different parameters VSWR input resistance radiation pattern and current distribution of the proposed antenna.

  8. A method to automate the radiological survey process

    International Nuclear Information System (INIS)

    Berven, B.A.; Blair, M.S.

    1987-01-01

    This document describes the USRAD system, a hardware/software ranging and data transmission system, that provides real-time position data and combines it with other portable instrument measurements. Live display of position data and onsite data reduction, presentation, and formatting for reports and automatic transfer into databases are among the unusual attributes of USRADS. Approximately 25% of any survey-to-survey report process is dedicated to data recording and formatting, which is eliminated by USRADS. Cost savings are realized by the elimination of manual transcription of instrument readout in the field and clerical formatting of data in the office. Increased data reliability is realized by ensuring complete survey coverage of an area in the field, by elimination of mathematical errors in conversion of instrument readout to unit concentration, and by elimination of errors associated with transcribing data from the field into report format. The USRAD system can be adapted to measure other types of pollutants or physical/chemical/geological/biological conditions in which portable instrumentation exists. 2 refs., 2 figs

  9. Evaluation of integrity of radiation sources of nuclear gauges

    International Nuclear Information System (INIS)

    Torohate, Wiclif Francisco

    2016-01-01

    Nuclear equipment meters are mainly used in the industry in quality control and process control. The principle of operation consists in a shielded radioactive source together with a radiation detector such that the radiation interacts with the material to be analyzed before reaching the detector, providing real time data. Can be as their fixed and mobile mobility, the unique properties of ionizing radiation are used in three basic modes, transmission, backscatter or dispersion or induced (reactive). With the advancement and technological modernization in the world, the demand for nuclear gauges becomes increasingly larger. Currently in Brazil there are about 465 process control plants and 21 portable systems and Mozambique about 45 facilities using nuclear gauges. This font registration is done through a process called source inventory that allows also to know the category of the source, the danger or risk to human health that the source offers. The handling of this equipment requires personnel, certified, skilled and well trained in radiation protection area in accordance with the requirements of the various CNEN Rules. Due to the presence of radioactive source and because these devices are used by workers risk because there external radiation. In this context, we made the smear test in two fixed meters from the IRD industry laboratory, which determines the integrity of the source package, mandatory item in periodic integrity testing of the radiation source of this type of device. A set of procedures is made for its implementation as an evaluation of the radiological risk by radiological survey. It was intended to contribute to the learning handling and safe use of these meters. (author)

  10. Evaluating the quality, clinical relevance, and resident perception of the radiation oncology in-training examination: A national survey.

    Science.gov (United States)

    Kim, Hyun; Bar Ad, Voichita; McAna, John; Dicker, Adam P

    2016-01-01

    The yearly radiation oncology in-training examination (ITE) by the American College of Radiology is a widely used, norm-referenced educational assessment, with high test reliability and psychometric performance. We distributed a national survey to evaluate the academic radiation oncology community's perception of the ITE. In June 2014, a 7-question online survey was distributed via e-mail to current radiation oncology residents, program directors, and attending physicians who had completed residency in the past 5 years or junior attendings. Survey questions were designed on a 5-point Likert scale. Sign test was performed with P ≤ .05 considered statistically different from neutral. Thirty-one program directors (33.3%), 114 junior attendings (35.4%), and 225 residents (41.2%) responded. Junior attendings and program directors reported that the ITE directly contributed to their preparation for the American Board of Radiology written certification (P = .050 and .004, respectively). Residents did not perceive the examination as an accurate assessment of relevant clinical and scientific knowledge (P ITE. Although the current examination allows limited feedback, establishing a venue for individualized feedback may allow continual and timely improvement of the ITE. Adopting a criterion-referenced examination may further increase resident investment in and utilization of this valuable learning tool. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  11. Temporal evaluation of radiation detection system, used by the division of radiation protection of the Navy Technological Centre in Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha; Acosta, Clarice de Freitas; Ikari, Andreza Iris R.; Ferreira, Marcio de Oliveira; Alves, Henrique da Silva; Duarte, Marcelo Antonio

    2011-01-01

    This work presents a temporal evaluation of the radiation detection system used by in division of radiation protection of the CTMSP, Sao Paulo, Brazil. About fifty efficiencies results of the system were compiled over the last two years for this purpose. Less than 1% of the standard deviation was found for both portable and fixed detectors, which indicates a significant stability of the detection system used in CTMSP over the period analyzed. (author)

  12. Radiation hygiene survey on human and cattle in Fukushima prefecture no health hazards due to low doses

    International Nuclear Information System (INIS)

    Takada, Jun

    2012-01-01

    Radiation hygiene survey has been conducted about Fukushima Dai-Ichi nuclear power station disaster caused by tsunami in the East Japan earthquake area on March 11 th 2011. Our surveys reveal that a public annual dose is 10 mSv following low-dose and health hazards shall not be concluded by the methods of in situ dose evaluation. This study has been focused on internal dosimetries of iodine-131 in thyroid and of cesium-134, 137 in whole body. Especially we continuously have been studing radiation hygiene on cattle livestock in Namie town within 20 km zone around the Fukushima Daiichi nuclear power station, and found no problem for the recovery. (author)

  13. Review of portable applications of fuel cell technology 2008; Teknikbevakning av portabla tillaempningar foer braenslecellstekniken 2008

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, Eva; Lundblad, Anders; Wennstam, Emelie

    2009-03-15

    The definition of portable fuel cells, or micro fuel cells as they are often called, is usually that its nominal power is below 250 W. There are, however, several widely separated applications and technical challenges in the span up to 250 W. Portable fuel cells from 1-10 W have potential applications in hand held electronics, wireless sensors, wireless networks and less power demanding equipment for outdoor life such as bicycle lamps, head lamps etc. The technical challenges involved here are mainly about cost, miniaturizing, dealing with heat rejection/cooling, stability/life and the fuel cell infrastructure - how shall the user 'fill' his/her fuel cell? Medium-sized, portable fuel cells between 10-50 W have potential applications in portable military equipment, larger portable electronics such as DVD players, camcorders and laptops (both for direct power and for charging of integrated batteries), to operate rescue equipment and as reserve power, and to replace some stationary power (APU). Also in this area challenges lie in cost, miniaturizing and heat rejection. Larger portable fuel cells of 50-250 W can for example be used in military equipment for charging of batteries, in rescue equipment and medical treatments, in boats and mobile homes, in small electric vehicles (manned or unmanned) and for remote power. In this type of replacement products the cost aspect is important, e g for material and system components. In this technique survey report we have analysed in total 31 pure micro fuel cell companies. In addition, we have also studied 14 larger electronic companies active in the fuel cell development. The three main technologies for portable fuel cell systems are Proton Exchange Membrane Fuel Cells (PEMFC), Direct Methanol Fuel Cells (DMFC) and Solid Oxide Fuel Cells (SOFC), Micro fuel cells that have been sold and have been available on the market up till today have been of the PEMFC and DMFC type and have mainly been used, to a limited extent

  14. Development of aerial gamma radiation survey system III

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Sakamoto, Ryuichi; Saito, Kimiaki; Tsutsumi, Masahiro; Moriuchi, Shigeru; Miyasaka, Satoshi.

    1985-01-01

    An aerial gamma-ray survey system using a helicopter has been developed since 1980 in order to perform quick gamma-ray survey covering a wide area. To form a line in the chain of the development, a series of flight measurements were conducted in Watarase reservoir, Tochigi prefecture, in which artificial gamma-ray fields were realized using 60 Co (100 and 400 mCi) and 137 Cs (100 and 300 mCi) point sources located on the ground. For the purpose of obtaining gamma-ray pulse height spectra in the field, 6 sets of NaI(Tl) scientillation detectors were prepared. These sets of detectors consist of ones for evaluation with high accuracy as the standard, for intercomparison with other authors' results, and for practical use. Two sets of them were boarded for each flight considering the exposure rate level and detector's sensitivity. The flight measurements were performed in a space of 20 m to 500 m in altitude, and 0 m to 500 m in horizontal distance from the source. The experimental results of the spatial gamma-ray distribution for each gamma-ray field satisfactorily agreed with calculational results by Monte Carlo method. Throughout this experiment, characteristics of this survey system and detectors were clarified, and versatile data processing and analysis code was completed. Also, a method for subtraction of background exposure rate in a field including artificial radiation component was discussed using energy band information, and the coefficients for this method were determined. These data obtained are expected to be used as widely applicable data not only for the interpretation of measured value, but also for analysis of environmental gamma-ray field. (author)

  15. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G. [Y-12 National Security Complex; Gose, B. T. [Y-12 National Security Complex; Bogard, James S [ORNL

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  16. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    International Nuclear Information System (INIS)

    Veinot, K.G.; Gose, B.T.; Bogard, James S.

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the persons blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metal and solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  17. Possible extensions of XIA's digital spectrometer technology to portable and remote monitoring instrumentation

    International Nuclear Information System (INIS)

    Warburton, W.K.; Darknell, D.A.; Hubbard, B.

    1998-01-01

    The XIA DXP-4C, a 4 channel, CAMAC based X-ray spectrometer, is based on digitally processing directly digitized preamplifier signals. Designed for instrumenting multi-detector arrays for synchrotron radiation applications, the DXP-4C was optimized for very high count rates at a low cost per detector channel. These design constraints coincidentally lead to an instrument which is very compact and relatively low power (3.4 W/channel), considering its count rate and MCA capabilities, and which therefore offers interesting possibilities for effective extension to portable applications. Further, because all functions (gain, filter parameters, pileup inspection criteria and internal calibrations) are digitally controlled, the design can be readily adapted to a large variety of user interfaces, including remote access interfaces. Here we present the basics of the design and examine approaches to lowering the power to less than 300 mW/channel while retaining count rate capabilities in excess of 50,000 cps. We then consider the engineering issues associated with portable and remote spectrometry applications, examining in detail the three cases of a lead paint detector, a remote contamination monitor, and a space mission spectrometer. (author)

  18. Trial manufacture of portable type `WISH BOX`; Kahangata WISH BOX no shisaku kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ushiyama, I; Sakuma, H; Qin, W [Ashikaga Institute of Technology, Tochigi (Japan); Onai, Y

    1996-10-27

    This paper proposes the small portable type power source `WISH BOX` (wind and solar hybrid) composed of a small wind power generator and solar cell panels. Since solar radiation and wind power are complementary to each other in seasons, day and night, and fine and cloudy weather, WISH BOX is useful for standalone power source in non-power areas of developing countries, life spot in disasters, and outdoor leisure. The most small light-weight high-performance AIR303 produced by Southwest Windpower Co., USA is used as wind power generator, and two 50W solar cell panels HSC-5010-S produced by Daido Hokusan Co. is used. Sealed lead storage batteries (12V, 20Ah each) are also connected to cope with load fluctuation. In comparison with conventional portable gasoline engine generators, this environment-friendly generator is featured by fuel-free, no emission of gases, no noises and no fire occurrence, and can also supply stable power with small batteries even in the nighttime and cloudy weather by combining wind power. The generator of 400,000 yen is now in field experiment. 2 refs., 5 figs.

  19. Portable telepathology: methods and tools.

    Science.gov (United States)

    Alfaro, Luis; Roca, Ma José

    2008-07-15

    Telepathology is becoming easier to implement in most pathology departments. In fact e-mail image transmit can be done from almost any pathologist as a simplistic telepathology system. We tried to develop a way to improve capabilities of communication among pathologists with the idea that the system should be affordable for everybody. We took the premise that any pathology department would have microscopes and computers with Internet connection, and selected a few elements to convert them into a telepathology station. Needs were reduced to a camera to collect images, a universal microscope adapter for the camera, a device to connect the camera to the computer, and a software for the remote image transmit. We found out a microscope adapter (MaxView Plus) that allowed us connect almost any domestic digital camera to any microscope. The video out signal from the camera was sent to the computer through an Aver Media USB connector. At last, we selected a group of portable applications that were assembled into a USB memory device. Portable applications are computer programs that can be carried generally on USB flash drives, but also in any other portable device, and used on any (Windows) computer without installation. Besides, when unplugging the device, none of personal data is left behind. We selected open-source applications, and based the pathology image transmission to VLC Media Player due to its functionality as streaming server, portability and ease of use and configuration. Audio transmission was usually done through normal phone lines. We also employed alternative videoconferencing software, SightSpeed for bi-directional image transmission from microscopes, and conventional cameras allowing visual communication and also image transmit from gross pathology specimens. All these elements allowed us to install and use a telepathology system in a few minutes, fully prepared for real time image broadcast.

  20. Forensic Analysis of the Sony Playstation Portable

    Science.gov (United States)

    Conrad, Scott; Rodriguez, Carlos; Marberry, Chris; Craiger, Philip

    The Sony PlayStation Portable (PSP) is a popular portable gaming device with features such as wireless Internet access and image, music and movie playback. As with most systems built around a processor and storage, the PSP can be used for purposes other than it was originally intended - legal as well as illegal. This paper discusses the features of the PSP browser and suggests best practices for extracting digital evidence.

  1. Technical Evaluation Report 57: Portable Applications in Mobile Education

    Directory of Open Access Journals (Sweden)

    Jon Baggaley

    2006-09-01

    Full Text Available Portable software applications can be carried on a convenient storage medium such as a USB drive, and offer numerous benefits to mobile teachers and learner. The article illustrates the growing field of ‘portable apps’ in reviews of seven contrasting products. These represent the major categories of document editing, email maintenance, Internet browsing, instant messaging, file transfer, multimedia presentation, and anti-virus protection. Emphasis is placed on ways to use ‘portable apps’ to overcome the common problems of Internet usage during travel.

  2. 47 CFR 87.47 - Application for a portable aircraft station license.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Application for a portable aircraft station... SPECIAL RADIO SERVICES AVIATION SERVICES Applications and Licenses § 87.47 Application for a portable aircraft station license. A person may apply for a portable aircraft radio station license if the need...

  3. Radiation protection practices and related continuing professional education in dental radiography: A survey of practitioners in the North-east of England

    International Nuclear Information System (INIS)

    Davies, Ceri; Grange, Stuart; Trevor, Margaret M.

    2005-01-01

    Purpose: To establish the level of implementation of recommendations from the National Radiological Protection Board, relating to best radiation protection practice in dental radiography within general dental practices in the North-east of England. To survey the opinion of practitioners on the availability of related post-graduate courses in the region. Methods: A postal survey in the form of a self-reported questionnaire was mailed to all practices in the North-east of England in November 2000. The questionnaire, consisting of closed and open-ended questions, was to be completed where possible by the resident radiation protection supervisor. Results: Two hundred and sixteen practices responded to the questionnaire, a response rate of 53%. The survey revealed variation in the standards of application of best radiation protection practice. Some 23% of practitioners had not attended any post-graduate courses on radiation protection since qualifying. Post-graduate education provision on radiation protection in the region was considered insufficient by 51% of respondents. Conclusions: It is concluded that a significant proportion of practices were not making full use of opportunities to reduce dose to their patients. In addition, a small number of practices had untrained staff acting as the Radiation Protection Supervisor. A significant proportion of practitioners had not been updated in radiation protection practices within a 5-year period, and this may account for the failure to implement best radiographic practice. Over half felt that there was insufficient availability of post-graduate courses in radiation protection. The regional provision of continuing professional education in this field may need development

  4. Optical fiber-applied radiation detection system

    International Nuclear Information System (INIS)

    Nishiura, Ryuichi; Uranaka, Yasuo; Izumi, Nobuyuki

    2001-01-01

    A technique to measure radiation by using plastic scintillation fibers doped radiation fluorescent (scintillator) to plastic optical fiber for a radiation sensor, was developed. The technique contains some superiority such as high flexibility due to using fibers, relatively easy large area due to detecting portion of whole of fibers, and no electromagnetic noise effect due to optical radiation detection and signal transmission. Measurable to wide range of and continuous radiation distribution along optical fiber cable at a testing portion using scintillation fiber and flight time method, the optical fiber-applied radiation sensing system can effectively monitor space radiation dose or apparatus operation condition monitoring. And, a portable type scintillation optical fiber body surface pollution monitor can measure pollution concentration of radioactive materials attached onto body surface by arranging scintillation fiber processed to a plate with small size and flexibility around a man to be tested. Here were described on outline and fundamental properties of various application products using these plastic scintillation fiber. (G.K.)

  5. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  6. Operation Praetorian onsite radiological safety report, October 1981-September 1982

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1983-09-01

    PRAETORIAN was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1981 through September 30, 1982. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeros before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  7. Operation QUICKSILVER. Onsite radiological safety report, October 1978-September 1979

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1980-02-01

    QUICKSILVER was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1978 to September 30, 1979. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeroes before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific optional procedures are defined

  8. Operation CRESSET: onsite radiological safety report, October 1977--September 1978

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1979-06-01

    CRESSET was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1977 to September 30, 1978. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeroes before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  9. Operation FULCRUM: onsite radiological safety report, October 1976--September 1977

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1978-03-01

    FULCRUM was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1976 to September 30, 1977. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeroes before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  10. Operation GUARDIAN onsite radiological safety report, October 1980-September 1981

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1983-02-01

    GUARDIAN was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1980 to September 30, 1981. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection intruments surveyed reentry routes into ground zeroes before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  11. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  12. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  13. A Portable Passive Physiotherapeutic Exoskeleton

    Directory of Open Access Journals (Sweden)

    Dasheek Naidu

    2012-10-01

    Full Text Available The public healthcare system in South Africa is in need of urgent attention in no small part because there has been an escalation in the number of stroke victims which could be due to the increase in hypertension in this urbanizing society. There is a growing need for physiotherapists and occupational therapists in the country, which is further hindered by the division between urban and rural areas. A possible solution is a portable passive physiotherapeutic exoskeleton device. The exoskeleton device has been formulated to encapsulate methodologies that enable the anthropomorphic integration between a biological and mechatronic limb. A physiotherapeutic mechanism was designed to be portable and adjustable, without limiting the spherical motion and workspace of the human arm. The exoskeleton was designed to be portable in the sense that it could be transported geographically. It is a complete device allowing for motion in the shoulder, elbow, wrist and hand joints. The inverse kinematics was solved iteratively via the Damped Least Squares (DLS method. The electronic and computer system allowed for professional personnel to either change an individual joint or a combination of joints angles via the kinematic models. A ramp PI controller was established to provide a smooth response to simulate the passive therapy motion.

  14. Privacy preservation and information security protection for patients' portable electronic health records.

    Science.gov (United States)

    Huang, Lu-Chou; Chu, Huei-Chung; Lien, Chung-Yueh; Hsiao, Chia-Hung; Kao, Tsair

    2009-09-01

    As patients face the possibility of copying and keeping their electronic health records (EHRs) through portable storage media, they will encounter new risks to the protection of their private information. In this study, we propose a method to preserve the privacy and security of patients' portable medical records in portable storage media to avoid any inappropriate or unintentional disclosure. Following HIPAA guidelines, the method is designed to protect, recover and verify patient's identifiers in portable EHRs. The results of this study show that our methods are effective in ensuring both information security and privacy preservation for patients through portable storage medium.

  15. Portable instrumentation for quantitatively measuring radioactive contamination levels and for monitoring the effectiveness of decontamination and decommissioning activities

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-06-01

    Two completely portable high-resolution germanium diode spectrometer systems are described. These detectors are capable of measuring transuranics, activation products, and fission products, including 90 Sr, at sensitivities below the uncontrolled release criteria. The detectors measure x-rays, gamma-rays, or bremsstrahlung radiation as required and have been calibrated for a variety of decontamination and decommissioning scenarios. A description of a new technology for the in-situ determination of 90 Sr is given

  16. Portable instrumentation for quantitatively measuring radioactive contamination levels and for monitoring the effectiveness of decontamination and decommissioning activities

    Energy Technology Data Exchange (ETDEWEB)

    Brodzinski, R.L.

    1983-06-01

    Two completely portable high-resolution germanium diode spectrometer systems are described. These detectors are capable of measuring transuranics, activation products, and fission products, including /sup 90/Sr, at sensitivities below the uncontrolled release criteria. The detectors measure x-rays, gamma-rays, or bremsstrahlung radiation as required and have been calibrated for a variety of decontamination and decommissioning scenarios. A description of a new technology for the in-situ determination of /sup 90/Sr is given.

  17. Definitive Stereotactic Body Radiotherapy (SBRT) for Extracranial Oligometastases: An International Survey of >1000 Radiation Oncologists.

    Science.gov (United States)

    Lewis, Stephen L; Porceddu, Sandro; Nakamura, Naoki; Palma, David A; Lo, Simon S; Hoskin, Peter; Moghanaki, Drew; Chmura, Steven J; Salama, Joseph K

    2017-08-01

    Stereotactic body radiotherapy (SBRT) is often used to treat patients with oligometastases (OM). Yet, patterns of SBRT practice for OM are unknown. Therefore, we surveyed radiation oncologists internationally, to understand how and when SBRT is used for OM. A 25-question survey was distributed to radiation oncologists. Respondents using SBRT for OM were asked how long they have been treating OM, number of patients treated, organs treated, primary reason for use, doses used, and future intentions. Respondents not using SBRT for OM were asked reasons why SBRT was not used and intentions for future adoption. Data were analyzed anonymously. We received 1007 surveys from 43 countries. Eighty-three percent began using SBRT after 2005 and greater than one third after 2010. Eighty-four percent cited perceived treatment response/durability as the primary reason for using SBRT in OM patients. Commonly treated organs were lung (90%), liver (75%), and spine (70%). SBRT dose/fractionation schemes varied widely. Most would offer a second course to new OM. Nearly all (99%) planned to continue and 66% planned to increase SBRT for OM. Of those not using SBRT, 59% plan to start soon. The most common reason for not using SBRT was lack of clinical efficacy (48%) or lack of necessary image guidance equipment (34%). Radiation oncologists are increasingly using SBRT for OM. The main reason for not using SBRT for OM is a perceived lack of evidence demonstrating clinical advantages. These data strengthen the need for robust prospective clinical trials (ongoing and in development) to demonstrate clinical efficacy given the widespread adoption of SBRT for OM.

  18. Patient information about radiation therapy: a survey in Europe

    International Nuclear Information System (INIS)

    Hubert, Annie; Kantor, Guy; Dilhuydy, Jean-Marie; Toulouse, Claude; Germain, Colette; Le Polles, Gisele; Salamon, Roger; Scalliet, Pierre

    1997-01-01

    Background and purpose: We performed a survey to evaluate the present status and means of information given to patients treated by radiotherapy. A short questionnaire was sent, with the help of ESTRO, to 746 European heads of department with a request to send specific documents used for informing the patient. Within 2 months (March and April 1996) we received 290 answers (39%) and 97 centres sent documents. Materials and methods: Analysis of the questionnaire and the documents was performed quantitatively with usual statistical methods and qualitatively with a socio-anthropological method of content analysis. Results: Analysis of the questionnaire shows the major role of the radiation oncologist in giving information and writing documents. The 298 different samples sent from 97 centres represent a wide panel with a booklet of general information (59 booklets/57 centres), practical advice and specific explanations (177 documents/49 centres) and informed consent (36 documents/28 centres). The anthropological study was centred on the way information was given, evaluation of the patient's understanding and analysis of documents sent. Conclusion: This preliminary survey needs to be completed by a study, including the patient's point of view and needs, about the information given

  19. Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania.

    Science.gov (United States)

    Valuckiene, Zivile; Jurenas, Martynas; Cibulskaite, Inga

    2016-09-01

    Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optimization techniques among interventional cardiologists in Lithuania. Interventional cardiologists of five cardiac centres were interviewed by anonymized questionnaire, addressing personal use of protective garments, shielding, table/detector positioning, frame rate (FR), resolution, field of view adjustment and collimation. Effective patient doses were compared between operators who work with and without x-ray optimization. Thirty one (68.9%) out of 45 Lithuanian interventional cardiologists participated in the survey. Protective aprons were universally used, but not the thyroid collars; 35.5% (n  =  11) operators use protective eyewear and 12.9% (n  =  4) wear radio-protective caps; 83.9% (n  =  26) use overhanging shields, 58.1% (n  =  18)-portable barriers; 12.9% (n  =  4)-abdominal patient's shielding; 35.5% (n  =  11) work at a high table position; 87.1% (n  =  27) keep an image intensifier/receiver close to the patient; 58.1% (n  =  18) reduce the fluoroscopy FR; 6.5% (n  =  2) reduce the fluoro image detail resolution; 83.9% (n  =  26) use a 'store fluoro' option; 41.9% (N  =  13) reduce magnification for catheter transit; 51.6% (n  =  16) limit image magnification; and 35.5% (n  =  11) use image collimation. Median effective patient doses were significantly lower with x-ray optimization techniques in both diagnostic and therapeutic interventions. Many of the ionizing radiation exposure reduction tools and techniques are underused by a considerable proportion of interventional cardiology operators. The application of basic radiation protection tools and

  20. Evaluation of a flat panel digital radiographic system for low-dose portable imaging of neonates

    International Nuclear Information System (INIS)

    Samei, Ehsan; Hill, Jeanne G.; Frey, G. Donald; Southgate, W. Michael; Mah, Eugene; Delong, David

    2003-01-01

    The purpose of this study was to evaluate the clinical utility of an investigational flat-panel digital radiography system for low-dose portable neonatal imaging. Thirty image-pairs from neonatal intensive care unit patients were acquired with a commercial Computed Radiography system (Agfa, ADC 70), and with the investigational system (Varian, Paxscan 2520) at one-quarter of the exposure. The images were evaluated for conspicuity and localization of the endings of ancillary catheters and tubes in two observer performance experiments with three pediatric radiologists and three neonatologists serving as observers. The results indicated no statistically significant difference in diagnostic quality between the images from the investigational system and from CR. Given the investigational system's superior resolution and noise characteristics, observer results suggest that the high detective quantum efficiency of flat-panel digital radiography systems can be utilized to decrease the radiation dose/exposure to neonatal patients, although post-processing of the images remains to be optimized. The rapid availability of flat-panel images in portable imaging was found to be an added advantage for timely clinical decision-making

  1. Low-cost portable TRNG, implementation and evaluation

    Directory of Open Access Journals (Sweden)

    Fermevc Igor

    2016-01-01

    Full Text Available This paper will show one of many possible hardware implementations of random sequence generators and give a short survey on existing work related to techniques used for producing true random bits. By using cheap electronic components found in every specialized store such as 8-bit RISC microcontroler, double analogue comparator chip and USB to RS232 interface integrated circuit, we were able to produce a low cost, higly portable device that outputs random sequences with excellent statistical characteristics and high entropy. The source of randomness is a mix of techniques such as electronic noise, phase noise and oscillator jitter. The device in question has a built-in debiasing algorithm similar to [1] and a security mechanism that protects the end user by constantly monitoring the quality of digitized noise signal. Finaly, we will show the results of comparative analysis of data acquired from our device and „random.org“ online service.

  2. A Portable Burn Pan for the Disposal of Excess Propellants

    Science.gov (United States)

    2016-06-01

    2013 - 06/01/2016 A Portable Burn Pan for the Disposal of Excess Propellants Michael Walsh USA CRREL USA CRREL 72 Lyme Road Hanover, NH 03755...Army Alaska XRF X-Ray Florescence vii ACKNOWLEDGEMENTS Project ER-201323, A Portable Burn Pan for the Disposal of Gun Propellants, was a very...contamination problem while allowing troops to train as they fight, we have developed a portable training device for burning excess gun propellants. 1.1

  3. Development results of portable gamma-radiation HPGe spectrometer with electric cooling for field applications

    International Nuclear Information System (INIS)

    Kondrat'ev, V.; Loshevich, E.; Pchelintsev, A.; Sokolov, A.; Gostilo, V.

    2015-01-01

    The paper presents development results of a portable spectrometer based on high purity germanium (HPGe spectrometer) with Stirling electric cooler for field applications. The spectrometer cryostat allows installation of HPGe coaxial detectors with efficiency up to 40% and planar detectors with sensitive area up to 3000 mm2. The detector cooling time is not more than 8 hours. Despite the mechanical vibrations due to electric cooler operation, the obtained energy resolution of the spectrometer with coaxial detector of 10% efficiency was less than 1,0 and 2,0 keV by energies 122 and 1332 keV accordingly. Miniature processor device (Android) allows control for all operation modes of the spectrometer, provides self diagnostics, initial procession, indication and spectra accumulation

  4. Portable sensor for hazardous waste

    Energy Technology Data Exchange (ETDEWEB)

    Piper, L.G.; Fraser, M.E.; Davis, S.J. [Physical Sciences Inc., Andover, MA (United States)

    1995-10-01

    We are beginning the second phase of a three and a half year program designed to develop a portable monitor for sensitive hazardous waste detection. The ultimate goal of the program is to develop our concept to the prototype instrument level. Our monitor will be a compact, portable instrument that will allow real-time, in situ, monitoring of hazardous wastes. This instrument will be able to provide the means for rapid field screening of hazardous waste sites to map the areas of greatest contamination. Remediation efforts can then focus on these areas. Further, our instrument can show whether cleanup technologies are successful at reducing hazardous materials concentrations below regulated levels, and will provide feedback to allow changes in remediation operations, if necessary, to enhance their efficacy.

  5. The state of survivorship care in radiation oncology: Results from a nationally distributed survey.

    Science.gov (United States)

    Frick, Melissa A; Rosenthal, Seth A; Vapiwala, Neha; Monzon, Brian T; Berman, Abigail T

    2018-04-18

    Survivorship care has become an increasingly critical component of oncologic care as well as a quality practice and reimbursement metric. To the authors' knowledge, the current climate of survivorship medicine in radiation oncology has not been investigated fully. An institutional review board-approved, Internet-based survey examining practices and preparedness in survivorship care was distributed to radiation oncology practices participating in the American College of Radiology Radiation Oncology Practice Accreditation program between November 2016 and January 2017. A total of 78 surveys were completed. Among these, 2 were nonphysicians, resulting in 76 evaluable responses. Radiation oncologists (ROs) frequently reported that they are the primary provider in the evaluation of late toxicities and the recurrence of primary cancer. Although approximately 68% of ROs frequently discuss plans for future care with survivors, few provide a written survivorship care plan to their patients (18%) or the patients' primary care providers (24%). Patient prognosis, disease site, and reimbursement factors often influence the provision of survivorship care. Although ROs report that several platforms offer training in survivorship medicine, the quality of these resources is variable and extensive instruction is rare. Fewer than one-half of ROs believe they are expertly trained in survivorship care. ROs play an active role within the multidisciplinary team in the cancer-related follow-up care of survivors. Investigation of barriers to the provision of survivorship care and optimization of service delivery should be pursued further. The development of high-quality, easily accessible educational programming is needed so that ROs can participate more effectively in the care of cancer survivors. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.

  6. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  7. Portable Data Acquisition System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a portable data acquisition system (PDAT) that can be easily transported and set up at remote locations to display and archive...

  8. Radiation protection training of radiation safety officers in Finland in 2008

    International Nuclear Information System (INIS)

    Havukainen, R.; Bly, R.; Markkanen, M.

    2009-11-01

    The Radiation and Nuclear Safety Authority (STUK) carried out a survey on the radiation protection training of radiation safety officers (RSO) in Finland in 2008. The aim of the survey was to obtain information on the conformity and uniformity of the training provided in different training organisations. A previous survey concerning radiation protection training was carried out in 2003. That survey determined the training needs of radiation users and radiation safety officers as well the radiation protection training included in vocational training and supplementary training. This report presents the execution and results of the survey in 2008. According to the responses, the total amount of RSO training fulfilled the requirements presented in Guide ST 1.8 in the most fields of competence. The emphasis of the RSO training differed between organisations, even for training in the same field of competence. Certain issues in Guide ST 1.8 were dealt quite superficially or even not at all in some training programmes. In some fields of competence, certain matters were entirely left to individual study. No practical training with radiation equipment or sources was included in the RSO training programme of some organisations. Practical training also varied considerably between organisations, even within the same field of competence. The duties in the use of radiation were often considered as practical training with radiation equipment and sources. Practical training from the point of view of a radiation safety officer was brought up in the responses of only one organisation. The number of questions and criteria for passing RSO exams also varied between organisations. Trainers who provided RSO training for the use of radiation in health care sectors had reached a higher vocational training level and received more supplementary training in radiation protection in the previous 5 years than trainers who provided RSO training for the use of radiation in industry, research, and

  9. Nationwide radiation dose survey of computed tomography for fetal skeletal dysplasias

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu [National Center for Child Health and Development, Department of Radiology, Setagaya-ku, Tokyo (Japan); Sawai, Hideaki [Hyogo College of Medicine, Department of Obstetrics and Gynecology, Nishinomiya-shi, Hyogo (Japan); Murotsuki, Jun [Miyagi Children' s Hospital, Department of Maternal and Fetal Medicine, Sendai-shi, Miyagi (Japan); Tohoku University Graduate School of Medicine, Department of Advanced Fetal and Developmental Medicine, Sendai-shi, Miyagi (Japan); Nishimura, Gen [Tokyo Metropolitan Children' s Medical Center, Department of Pediatric Imaging, Fuchu-shi, Tokyo (Japan); Horiuchi, Tetsuya [National Center for Child Health and Development, Department of Radiology, Setagaya-ku, Tokyo (Japan); Osaka University, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Suita, Osaka (Japan)

    2014-08-15

    Recently, computed tomography (CT) has been used to diagnose fetal skeletal dysplasia. However, no surveys have been conducted to determine the radiation exposure dose and the diagnostic reference level (DRL). To collect CT dose index volume (CTDIvol) and dose length product (DLP) data from domestic hospitals implementing fetal skeletal 3-D CT and to establish DRLs for Japan. Scan data of 125 cases of 20 protocols from 16 hospitals were analyzed. The minimum, first-quartile, median, third-quartile and maximum values of CTDIvol and DLP were determined. The time-dependent change in radiation dose setting in hospitals with three or more cases with scans was also examined. The minimum, first-quartile, median, third-quartile and maximum CTDIvol values were 2.1, 3.7, 7.7, 11.3 and 23.1 mGy, respectively, and these values for DLP were 69.0, 122.3, 276.8, 382.6 and 1025.6 mGy.cm, respectively. Six of the 12 institutions reduced the dose setting during the implementation period. The DRLs of CTDIvol and DLP for fetal CT were 11.3 mGy and 382.6 mGy.cm, respectively. Institutions implementing fetal CT should use these established DRLs as the standard and make an effort to reduce radiation exposure by voluntarily decreasing the dose. (orig.)

  10. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

    1996-12-31

    Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

  11. Portable Decontamination and Sterilization System

    National Research Council Canada - National Science Library

    Bell, William; Smerjac, Suzanne; Smith, Bryan

    2004-01-01

    TDA Research, Inc., (TDA) is developing a portable system to generate chlorine dioxide, which can be used for biodecontamination of small items and to sterilize medical and dental instruments in austere environments...

  12. Wavelet Denoising of Mobile Radiation Data

    International Nuclear Information System (INIS)

    Campbell, D.B.

    2008-01-01

    The FY08 phase of this project investigated the merits of video fusion as a method for mitigating the false alarms encountered by vehicle borne detection systems in an effort to realize performance gains associated with wavelet denoising. The fusion strategy exploited the significant correlations which exist between data obtained from radiation detectors and video systems with coincident fields of view. The additional information provided by optical systems can greatly increase the capabilities of these detection systems by reducing the burden of false alarms and through the generation of actionable information. The investigation into the use of wavelet analysis techniques as a means of filtering the gross-counts signal obtained from moving radiation detectors showed promise for vehicle borne systems. However, the applicability of these techniques to man-portable systems is limited due to minimal gains in performance over the rapid feedback available to system operators under walking conditions. Furthermore, the fusion of video holds significant promise for systems operating from vehicles or systems organized into stationary arrays; however, the added complexity and hardware required by this technique renders it infeasible for man-portable systems

  13. Rapid monitoring of gaseous radionuclides using a portable spectrometer

    International Nuclear Information System (INIS)

    Chung, C.; Tsai, C.H.

    1995-01-01

    A field gamma ray spectrometer, consisting of a portable high purity germanium detector, portable multichannel analyser, and a notebook computer, was used to conduct in situ rapid scanning of radioactive Ar, Kr and Xe isotopes in the air around a nuclear facility. The portable gamma ray spectrometer was calibrated using Ar, Kr, and Xe radioisotopes, activated in a research reactor and released in a sealed chamber. The unit was further tested inside the reactor containment to monitor the concentration of 41 Ar. In a typical one hour field measurement, the detection limits for some rare gas radionuclides corresponded to dose rates around 0.1 nSv.h -1 , which is far less than the dose rate induced by derived air concentrations imposed by the authority. The dose rate due to ground level concentrations of gaseous radionuclides dispersed from a source, such a nuclear facility or nuclear test, can be monitored in a short period using the portable unit. (Author)

  14. Portable Thermoelectric Power Generator Coupled with Phase Change Material

    Directory of Open Access Journals (Sweden)

    Lim Chong C.

    2014-07-01

    Full Text Available Solar is the intermittent source of renewable energy and all thermal solar systems having a setback on non-functioning during the night and cloudy environment. This paper presents alternative solution for power generation using thermoelectric which is the direct conversion of temperature gradient of hot side and cold side of thermoelectric material to electric voltage. Phase change material with latent heat effect would help to prolong the temperature gradient across thermoelectric material for power generation. Besides, the concept of portability will enable different power source like solar, wasted heat from air conditioner, refrigerator, stove etc, i.e. to create temperature different on thermoelectric material for power generation. Furthermore, thermoelectric will generate direct current which is used by all the gadgets like Smartphone, tablet, laptop etc. The portable concept of renewable energy will encourage the direct usage of renewable energy for portable gadgets. The working principle and design of portable thermoelectric power generator coupled with phase change material is presented in this paper.

  15. Portable x-ray fluorescence spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    This report describes the application of portable X-ray fluorescence (XRF) spectrometry to characterize materials related to deactivation and decommissioning (D and D) of contaminated facilities. Two portable XRF instruments manufactured by TN Spectrace were used in a technology evaluation as part of the Large-Scale Demonstration Project (LSDP) held at the Chicago Pile-5 Research Reactor (CP-5) located at Argonne National Laboratory (ANL). The LSDP is sponsored by the US Department of Energy (DOE), Office of Science and Technology, Deactivation and Decommissioning Focus Are (DDFA). The objective of the LSDP is to demonstrate innovative technologies or technology applications potentially beneficial to the D and D of contaminated facilities. The portable XRF technology offers several potential benefits for rapid characterization of facility components and contaminants, including significant cost reduction, fast turnaround time,a nd virtually no secondary waste. Field work for the demonstration of the portable XRF technology was performed from August 28--September 3, 1996 and October 30--December 13, 1996

  16. Design of portable electrocardiogram device using DSO138

    Science.gov (United States)

    Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita

    2018-02-01

    Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

  17. A survey of energy saving techniques for mobile computers

    NARCIS (Netherlands)

    Smit, Gerardus Johannes Maria; Havinga, Paul J.M.

    1997-01-01

    Portable products such as pagers, cordless and digital cellular telephones, personal audio equipment, and laptop computers are increasingly being used. Because these applications are battery powered, reducing power consumption is vital. In this report we first give a survey of techniques for

  18. Method and Apparatus for the Portable Identification Of Material Thickness And Defects Along Uneven Surfaces Using Spatially Controlled Heat Application

    Science.gov (United States)

    Reilly, Thomas L. (Inventor); Jacobstein, A. Ronald (Inventor); Cramer, K. Elliott (Inventor)

    2006-01-01

    A method and apparatus for testing a material such as the water-wall tubes in boilers includes the use of a portable thermal line heater having radiation shields to control the amount of thermal radiation that reaches a thermal imager. A procedure corrects for variations in the initial temperature of the material being inspected. A method of calibrating the testing device to determine an equation relating thickness of the material to temperatures created by the thermal line heater uses empirical data derived from tests performed on test specimens for each material type, geometry, density, specific heat, speed at which the line heater is moved across the material and heat intensity.

  19. [Design and application of portable rescue vehicle].

    Science.gov (United States)

    Guo, Ying; Qi, Huaying; Wang, Shen

    2017-12-01

    The disease of critically ill patients was with rapid changes, and at any time faced the risk of emergency. The current commonly used rescue vehicles were larger and bulky implementation, which were not conducive to the operation, therefore the design of a portable rescue vehicle was needed. This new type of rescue vehicle is multi-layer folding structure, with small footprint, large storage space, so a variety of first aid things can be classified and put, easy to be cleaned and disinfected. In the rescue process, the portable rescue vehicles can be placed in the required position; box of various emergency items can be found at a glance with easy access; the height of the infusion stand can adjust freely according to the user height; the rescue vehicle handle can be easy to pull and adjust accord with human body mechanics principle. The portable rescue vehicle facilitates the operation of medical staff, and is worthy of clinical application.

  20. Modular remote radiation monitor

    International Nuclear Information System (INIS)

    Lacerda, Fabio; Farias, Marcos S.; Aghina, Mauricio A.C.; Oliveira, Mauro V.

    2013-01-01

    The Modular Remote Radiation Monitor (MRRM) is a novel radiation monitor suitable for monitoring environmental exposure to ionizing radiation. It is a portable compact-size low-power microprocessor-based electronic device which provides its monitoring data to other electronic systems, physically distant from it, by means of an electronic communication channel, which can be wired or wireless according to the requirements of each application. Besides its low-power highly-integrated circuit design, the Modular Remote Radiation Monitor is presented in a modular architecture, which promotes full compliance to the technical requirements of different applications while minimizing cost, size and power consumption. Its communication capability also supports the implementation of a network of multiple radiation monitors connected to a supervisory system, capable of remotely controlling each monitor independently as well as visualizing the radiation levels from all monitors. A prototype of the MRRM, functionally equivalent to the MRA-7027 radiation monitor, was implemented and connected to a wired MODBUS network of MRA-7027 monitors, responsible for monitoring ionizing radiation inside Argonauta reactor room at Instituto de Engenharia Nuclear. Based on the highly positive experimental results obtained, further design is currently underway in order to produce a consumer version of the MRRM. (author)

  1. Occupational radiation exposure monitoring among radiation workers in Nepal

    International Nuclear Information System (INIS)

    Bhatt, Chhavi Raj; Shrestha, Shanta Lall; Khanal, Tara; Ween, Borgny

    2008-01-01

    Nepal was accepted as a member of the IAEA in 2007. Nepal is one of the world's least developed countries and is defined in Health Level IV. The population counted 26.4 millions in 2007. The health care sector increases with new hospitals and clinics, however, Nepal has no radiation protection authority or radiation protection regulation in the country until now. The radiation producing equipment in the health sector includes conventional X-ray and dental X-ray equipment, fluoroscopes, mammography, CT, catheterization laboratory equipment, nuclear medicine facilities, a few linear accelerators, Co 60 teletherapy and High Dose Rate brachytherapy sources. The situation regarding dosimetry service for radiation workers is unclear. A survey has been carried out to give an overview of the situation. The data collection of the survey was performed by phone call interviews with responsible staff at the different hospitals and clinics. Data about different occupationally exposed staff, use of personal radiation monitoring and type of dosimetry system were collected. In addition, it was asked if dosimetry reports were compiled in files or databases for further follow-up of staff, if needed. The survey shows that less of 25% of the procedures performed on the surveyed hospitals and clinics are performed by staff with personnel radiation monitoring. Radiation monitoring service for exposed staff is not compulsory or standardized, since there is no radiation protection authority. Nepal has taken a step forward regarding radiation protection, with the IAEA membership, although there are still major problems that have to be solved. An evaluation of the existing practice of staff dosimetry can be the first helpful step for further work in building a national radiation protection authority. (author)

  2. Testing the application of portable scintillation unit HOU 22 SCS in determining ash content in coal

    International Nuclear Information System (INIS)

    Simon, L.; Barcalova, L.; Sok, V.; Kacena, V.

    1977-01-01

    Operating tests were conducted for determining the ash content of coal on the conveyor belt using a portable scintillation radiometric unit of the HOU22 SCS type. The apparatus operated on the principle of scattered gamma radiation from a 75 Se source with an activity of 18 MBq. The detection probe 41 mm in diameter was mounted at the inlet of the coal flow onto the conveyor belt. The accuracy of determination of the ash content of undersize coal used for power production (grain size 0 to 10 mm) was +-4.4%. (B.S.)

  3. Operation Grenadier. Onsite radiological safety report for announced nuclear tests, October 1984-September 1985

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1986-09-01

    Grenadier was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1984 through September 30, 1985. This report includes those experiments publicly announced. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeros before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  4. Operation fusileer onsite radiological safety report for announced nuclear tests, October 1983-September 1984

    International Nuclear Information System (INIS)

    Mullen, O.W.; Eubank, B.F.

    1985-08-01

    Fusileer was the name assigned to the series of underground nuclear experiments conducted at the Nevada Test Site from October 1, 1983 through September 30, 1984. This report is limited to announced nuclear tests. Remote radiation measurements were taken during and after each nuclear experiment by a telemetry system. Monitors with portable radiation detection instruments surveyed reentry routes into ground zeros before other planned entries were made. Continuous surveillance was provided while personnel were in radiation areas and appropriate precautions were taken to protect persons from unnecessary exposure to radiation and toxic gases. Protective clothing and equipment were issued as needed. Complete radiological safety and industrial hygiene coverage was provided during drilling and mineback operations. Telemetered and portable radiation detector measurements are listed. Detection instrumentation used is described and specific operational procedures are defined

  5. A Portable Piezoelectric Tactile Terminal for Braille Readers

    Directory of Open Access Journals (Sweden)

    Ramiro Velázquez

    2012-01-01

    Full Text Available This paper introduces a novel concept on reading assistive technologies for the blind: the TactoBook, a system that is able to translate entire electronic books (eBooks to Braille code and to reproduce them in portable electronic Braille terminals. The TactoBook consists of a computer-based translator that converts fast and automatically any eBook into Braille. The Braille version of the eBook is then encrypted as a file and stored in a USB memory drive which is later inserted and reproduced in a compact, lightweight, and highly-portable tactile terminal. In particular, this paper presents a piezoelectric ultrasonic actuation approach to design and implement such portable Braille terminal. Actuating mechanism, design concept, first prototype, and performance results are presented and discussed.

  6. Portable Applications in Mobile Education. Technical Evaluation Report 57

    Science.gov (United States)

    Baggaley, Jon

    2006-01-01

    Portable software applications can be carried on a convenient storage medium such as a USB drive, and offer numerous benefits to mobile teachers and learner. The article illustrates the growing field of "portable apps" in reviews of seven contrasting products. These represent the major categories of document editing, email maintenance,…

  7. Epidemiological surveys on the effects of low-level radiation dose: a comparative assessment. V. E

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K.S.B.

    1990-01-01

    These tables present data on the effects of low-level radiation dose for the following effects:- pre-conception irradiation and Down's Syndrome, pre-conception irradiation and reproductive damage, surveys of effect in relation to the source of radiation, distribution by maternal preconception exposure of the 7 most common major congenital abnormalities in the Japanese, pre-conception irradiation and childhood malignancies, parental gonadal dose at Hiroshima and Nagasaki in relation to leukemia, sex chromosome aneuploids in children of A-bomb survivors, untoward pregnancy outcomes by parental gonad dose, pre-conception irradiation and chromosomal abnormalities, and intra-uterine irradiation and intelligence. (author).

  8. Epidemiological surveys on the effects of low-level radiation dose: a comparative assessment. V. E

    International Nuclear Information System (INIS)

    Rose, K.S.B.

    1990-01-01

    These tables present data on the effects of low-level radiation dose for the following effects:- pre-conception irradiation and Down's Syndrome, pre-conception irradiation and reproductive damage, surveys of effect in relation to the source of radiation, distribution by maternal preconception exposure of the 7 most common major congenital abnormalities in the Japanese, pre-conception irradiation and childhood malignancies, parental gonadal dose at Hiroshima and Nagasaki in relation to leukemia, sex chromosome aneuploids in children of A-bomb survivors, untoward pregnancy outcomes by parental gonad dose, pre-conception irradiation and chromosomal abnormalities, and intra-uterine irradiation and intelligence. (author)

  9. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry.

    Science.gov (United States)

    Yung, Yeni P; Wickramasinghe, Raveendra; Vaikkinen, Anu; Kauppila, Tiina J; Veryovkin, Igor V; Hanley, Luke

    2017-07-18

    A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization (APPI). The laser ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that LDTD-APPI method should be useful for in-field sampling of plant and microbial communities, for example, by portable ambient MS. The feasibility of many portable MS applications is facilitated by the availability of relatively low cost, portable, battery-powered diode lasers. LDTD could also be coupled with plasma- or electrospray-based ionization for the analysis of a variety of solid samples.

  10. Environmental Gamma Radiation Measurements in Baskil District

    International Nuclear Information System (INIS)

    Canbazoglu, C.

    2008-01-01

    In this study, we have determined environmental gamma radiation dose rate in Baskil district which has very high granite content in its geographical structure. Gamma radiation dose rate measurements were achieved by portable radiation monitoring equipment based on the energy range between 40 keV and 1.3 MeV. The measurements were performed on asphalt and soil surface level and also one meter above the ground surface. The gamma dose rate was also performed inside and outside of buildings over the district. The dose rates were found to be between 8.46μR/h and 34.66 μR/h. Indoor and outdoor effective dose rate of the gamma radiation exposure has been calculated to be 523μSv/y and 196μSv/y, respectively

  11. Analysis of the spatial dose according to the type of radiation source used in multi-bed hospital room

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Dong Gun [Dept. of Nuclear Medicine, Dongnam Institute of Radiological and Medical Sciences Cancer center, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-09-15

    Medical radiation offers significant benefits in diagnosing and treating patients, but it also generates unnecessary radiation exposure to those nearby. Accordingly, the objective of the present study was to analyze spatial dose rate according to types of radiation source term in multi-bed hospital rooms occupied by patients and general public. MCNPX was used for geometric simulation of multi-bed hospital rooms and radiation source terms, while the radiation source terms were established as whole body bone scan patients and imaging using a portable X-ray generator. The results of simulation on whole body bone scan patients showed 3.46 μSv/hr to another patient position, while experimental results on imaging using a portable X-ray generator showed 1.47 × 10{sup -8} μSv/irradiation to another patient position in chest imaging and 2.97 × 10{sup -8} μSv/irradiation to another patient position in abdomen imaging. Multi-bed hospital room, unnecessary radiation generated in the surrounding patients, while legal regulations and systematic measures are needed for radiation exposure in multi-bed hospital rooms that are currently lacking in Korea.

  12. Usage of portable spectrometers for prevention of radioactive and nuclear materials illicit trafficking

    International Nuclear Information System (INIS)

    Bystrov, Evgenij; Antonau, Uladzimir; Gurinovich, Uladzimir; Kazhamiakin, Valery; Petrov, Vitaly; Shulhovich, Heorhi; Tischenko, Siarhei

    2008-01-01

    Full text: It is publicly known that radioactive and nuclear materials can be shielded not only with passive protection but also be masked with legally transported radioactive substances. These radioactive substances can be contained as medical radionuclides incorporated in human body or in cargos with high content of natural isotopes 40 K, 232 Th, 238 U, etc. This constitutes an additional serious obstacle to detection of radioactive substances trafficking. Dosimeters, search monitors or radiation portal monitors have insufficient capability for this objective. It is necessary to use much more intellectual instruments that can detect both gamma radiation and other types of radiation (neutron, alpha, beta), recognize radionuclide type and identify it with high probability. To address these objectives, we have developed portable scintillation gamma spectrometers AT6101 and AT6102 with neutron radiation detection and measurement of surface contamination with alpha and beta particles. Gamma scintillation spectrometry methods using NaI(Tl) crystal allow to detect source of gamma radiation, measure ambient dose rate equivalent of gamma radiation and identify radionuclide composition. The implemented spectrometry method of gamma radiation dose rate measurement using 'spectrum-dose' function allows to measure ambient dose rate equivalent of gamma radiation with relative error up to 20%. Radionuclide identification is based on channel-by-channel spectrum convolution with the second derivative from Gaussian function. Peak search and analysis and peak position comparison to energy values of gamma lines of library radionuclides is performed in convolution spectrum. Analysis of relative intensity of detected gamma lines with peak detection threshold overrun allows qualitative definition of radionuclide composition in object under examination. The special feature of the spectrometers is LED stabilization through spectrometric path. The stabilization system covers PEM, pre

  13. Effect of Radiological Countermeasures on Subjective Well-Being and Radiation Anxiety after the 2011 Disaster: The Fukushima Health Management Survey

    Directory of Open Access Journals (Sweden)

    Michio Murakami

    2018-01-01

    Full Text Available After the Fukushima Daiichi Nuclear Power Station accident in 2011, concerns about radiation exposure and decline in subjective well-being have been reported. To tackle these problems, various countermeasures in relation to radiation have been implemented. In this study, we comprehensively evaluated the effects of radiological countermeasures on subjective well-being (e.g., satisfaction with life (SWL and emotional well-being and radiation anxiety, through a questionnaire survey targeting Fukushima residents (N = 1023. Propensity scores matching was applied to evaluate significant effects of radiological countermeasures on subjective well-being and radiation anxiety. Among the radiological countermeasures, thyroid examination, whole body counter, and air dose monitoring showed the highest proportions of participation, utilization, and useful evaluation, suggesting a high degree of public attention focused on these countermeasures. The basic survey was associated with significant increases in SWL and self-rated health (SH. Thyroid examination was significantly associated with not only a reduction in radiation anxiety but also an increase of emotional stress, suggesting the importance of careful design of system and detailed communication. Food inspection was associated with deterioration in SH. Those who utilized explanatory meetings showed increases in sadness, worry, and radiation anxiety, indicating that additional attention is required of the experts and authorities involved in explanatory meetings.

  14. Effect of Radiological Countermeasures on Subjective Well-Being and Radiation Anxiety after the 2011 Disaster: The Fukushima Health Management Survey.

    Science.gov (United States)

    Murakami, Michio; Takebayashi, Yoshitake; Takeda, Yoshihito; Sato, Akiko; Igarashi, Yasumasa; Sano, Kazumi; Yasutaka, Tetsuo; Naito, Wataru; Hirota, Sumire; Goto, Aya; Ohira, Tetsuya; Yasumura, Seiji; Tanigawa, Koichi

    2018-01-12

    After the Fukushima Daiichi Nuclear Power Station accident in 2011, concerns about radiation exposure and decline in subjective well-being have been reported. To tackle these problems, various countermeasures in relation to radiation have been implemented. In this study, we comprehensively evaluated the effects of radiological countermeasures on subjective well-being (e.g., satisfaction with life (SWL) and emotional well-being) and radiation anxiety, through a questionnaire survey targeting Fukushima residents ( N = 1023). Propensity scores matching was applied to evaluate significant effects of radiological countermeasures on subjective well-being and radiation anxiety. Among the radiological countermeasures, thyroid examination, whole body counter, and air dose monitoring showed the highest proportions of participation, utilization, and useful evaluation, suggesting a high degree of public attention focused on these countermeasures. The basic survey was associated with significant increases in SWL and self-rated health (SH). Thyroid examination was significantly associated with not only a reduction in radiation anxiety but also an increase of emotional stress, suggesting the importance of careful design of system and detailed communication. Food inspection was associated with deterioration in SH. Those who utilized explanatory meetings showed increases in sadness, worry, and radiation anxiety, indicating that additional attention is required of the experts and authorities involved in explanatory meetings.

  15. Results of the 2013-2015 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Nabavizadeh, Nima, E-mail: nabaviza@ohsu.edu [Department of Radiation Medicine, Oregon Health and Science University, Portland, Oregon (United States); Burt, Lindsay M. [Department of Radiation Oncology, University of Utah, Salt Lake City, Utah (United States); Mancini, Brandon R. [Department of Therapeutic Radiology, Yale University, New Haven, Connecticut (United States); Morris, Zachary S. [Department of Human Oncology, University of Wisconsin, Madison, Wisconsin (United States); Walker, Amanda J. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Miller, Seth M. [Department of Radiation Oncology, University of North Carolina Chapel Hill, Chapel Hill, North Carolina (United States); Bhavsar, Shripal [Department of Radiation Oncology, Integris Cancer Institute, Oklahoma City, Oklahoma (United States); Mohindra, Pranshu [Department of Radiation Oncology, University of Maryland, Baltimore, Maryland (United States); Kim, Miranda B. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Kharofa, Jordan [Department of Radiation Oncology, University of Cincinnati, Cincinnati, Ohio (United States)

    2016-02-01

    Purpose: The purpose of this project was to survey radiation oncology chief residents to define their residency experience and readiness for independent practice. Methods and Materials: During the academic years 2013 to 2014 and 2014 to 2015, the Association of Residents in Radiation Oncology (ARRO) conducted an electronic survey of post-graduate year-5 radiation oncology residents in the United States during the final 3 months of training. Descriptive statistics are reported. Results: Sixty-six chief residents completed the survey in 2013 to 2014 (53% response rate), and 69 completed the survey in 2014 to 2015 (64% response rate). Forty to 85% percent of residents reported inadequate exposure to high-dose rate and low-dose rate brachytherapy. Nearly all residents in both years (>90%) reported adequate clinical experience for the following disease sites: breast, central nervous system, gastrointestinal, genitourinary, head and neck, and lung. However, as few as 56% reported adequate experience in lymphoma or pediatric malignancies. More than 90% of residents had participated in retrospective research projects, with 20% conducting resident-led prospective clinical trials and 50% conducting basic science or translational projects. Most chief residents reported working 60 or fewer hours per week in the clinical/hospital setting and performing fewer than 15 hours per week tasks that were considered to have little or no educational value. There was more than 80% compliance with Accreditation Council for Graduate Medical Education (ACGME) work hour limits. Fifty-five percent of graduating residents intended to join an established private practice group, compared to 25% who headed for academia. Residents perceive the job market to be more competitive than previous years. Conclusions: This first update of the ARRO chief resident survey since the 2007 to 2008 academic year documents US radiation oncology residents' experiences and conditions over a 2-year period

  16. Results of the 2013-2015 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States.

    Science.gov (United States)

    Nabavizadeh, Nima; Burt, Lindsay M; Mancini, Brandon R; Morris, Zachary S; Walker, Amanda J; Miller, Seth M; Bhavsar, Shripal; Mohindra, Pranshu; Kim, Miranda B; Kharofa, Jordan

    2016-02-01

    The purpose of this project was to survey radiation oncology chief residents to define their residency experience and readiness for independent practice. During the academic years 2013 to 2014 and 2014 to 2015, the Association of Residents in Radiation Oncology (ARRO) conducted an electronic survey of post-graduate year-5 radiation oncology residents in the United States during the final 3 months of training. Descriptive statistics are reported. Sixty-six chief residents completed the survey in 2013 to 2014 (53% response rate), and 69 completed the survey in 2014 to 2015 (64% response rate). Forty to 85% percent of residents reported inadequate exposure to high-dose rate and low-dose rate brachytherapy. Nearly all residents in both years (>90%) reported adequate clinical experience for the following disease sites: breast, central nervous system, gastrointestinal, genitourinary, head and neck, and lung. However, as few as 56% reported adequate experience in lymphoma or pediatric malignancies. More than 90% of residents had participated in retrospective research projects, with 20% conducting resident-led prospective clinical trials and 50% conducting basic science or translational projects. Most chief residents reported working 60 or fewer hours per week in the clinical/hospital setting and performing fewer than 15 hours per week tasks that were considered to have little or no educational value. There was more than 80% compliance with Accreditation Council for Graduate Medical Education (ACGME) work hour limits. Fifty-five percent of graduating residents intended to join an established private practice group, compared to 25% who headed for academia. Residents perceive the job market to be more competitive than previous years. This first update of the ARRO chief resident survey since the 2007 to 2008 academic year documents US radiation oncology residents' experiences and conditions over a 2-year period. This analysis may serve as a valuable tool for those seeking to

  17. Results of the 2013-2015 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States

    International Nuclear Information System (INIS)

    Nabavizadeh, Nima; Burt, Lindsay M.; Mancini, Brandon R.; Morris, Zachary S.; Walker, Amanda J.; Miller, Seth M.; Bhavsar, Shripal; Mohindra, Pranshu; Kim, Miranda B.; Kharofa, Jordan

    2016-01-01

    Purpose: The purpose of this project was to survey radiation oncology chief residents to define their residency experience and readiness for independent practice. Methods and Materials: During the academic years 2013 to 2014 and 2014 to 2015, the Association of Residents in Radiation Oncology (ARRO) conducted an electronic survey of post-graduate year-5 radiation oncology residents in the United States during the final 3 months of training. Descriptive statistics are reported. Results: Sixty-six chief residents completed the survey in 2013 to 2014 (53% response rate), and 69 completed the survey in 2014 to 2015 (64% response rate). Forty to 85% percent of residents reported inadequate exposure to high-dose rate and low-dose rate brachytherapy. Nearly all residents in both years (>90%) reported adequate clinical experience for the following disease sites: breast, central nervous system, gastrointestinal, genitourinary, head and neck, and lung. However, as few as 56% reported adequate experience in lymphoma or pediatric malignancies. More than 90% of residents had participated in retrospective research projects, with 20% conducting resident-led prospective clinical trials and 50% conducting basic science or translational projects. Most chief residents reported working 60 or fewer hours per week in the clinical/hospital setting and performing fewer than 15 hours per week tasks that were considered to have little or no educational value. There was more than 80% compliance with Accreditation Council for Graduate Medical Education (ACGME) work hour limits. Fifty-five percent of graduating residents intended to join an established private practice group, compared to 25% who headed for academia. Residents perceive the job market to be more competitive than previous years. Conclusions: This first update of the ARRO chief resident survey since the 2007 to 2008 academic year documents US radiation oncology residents' experiences and conditions over a 2-year period. This

  18. A mobile and portable trusted computing platform

    Directory of Open Access Journals (Sweden)

    Nepal Surya

    2011-01-01

    Full Text Available Abstract The mechanism of establishing trust in a computing platform is tightly coupled with the characteristics of a specific machine. This limits the portability and mobility of trust as demanded by many emerging applications that go beyond the organizational boundaries. In order to address this problem, we propose a mobile and portable trusted computing platform in a form of a USB device. First, we describe the design and implementation of the hardware and software architectures of the device. We then demonstrate the capabilities of the proposed device by developing a trusted application.

  19. External exposure rates from terrestrial radiation at Guarapari and Meaipe in Brazil

    International Nuclear Information System (INIS)

    Fujinami, N.; Koga, T.; Morishima, H.

    2000-01-01

    Recently epidemiological and cytogenetic studies on inhabitants living in high background radiation areas have been carried out in order to examine health effects of exposure to low dose radiation. Guarapari and Meaipe are towns built on the monazite sand region along the Atlantic coast in Brazil, which is one of the widely known high background radiation areas in the world. As an initial step toward studies on health effects of high background radiation on inhabitants living in Guarapari and Meaipe, we surveyed absorbed dose rates in air in these towns with a portable NaI(Tl) scintillation detector in September 1998. Sand and soil were also sampled there so as to determine the concentrations of Th-232 and Ra-226 in them. In Guarapari and Meaipe, dose rates in the streets ranged from 0.1 to 0.4 μ Gy/h except for a few places such as near the Areia Preta beach and Meaipe beach. Dose rates inside houses were lower than 0.2 μ Gy/h except that two houses attained a dose rate of 0.4 μ Gy/h. Our effective dose rate from external terrestrial irradiation (outdoors and indoors) was 0.17 μ Sv/h on the average, during the period of our three day stay in Guarapari and Meaipe. From comparison of our present values with those observed in the 1960s, which were cited in UNSCEAR reports, it is indicated that dose rate levels have decreased clearly in downtown, while the levels have scarcely changed in beaches and unpaved beach streets which have not been developed yet. This fact suggests that the natural radiation environment of Guarapari and Meaipe has varied with urbanization which brought paved streets, and changes in the structure and building materials of houses. A detailed survey is necessary in order to evaluate present absorbed dose rates in air in this area. (author)

  20. Portable DMFC system with methanol sensor-less control

    Energy Technology Data Exchange (ETDEWEB)

    Chen, C.Y.; Liu, D.H.; Huang, C.L.; Chang, C.L. [Institute of Nuclear Energy Research (INER), No. 1000, Wunhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546 (China)

    2007-05-15

    This work develops a prototype 20 W portable DMFC by system integration of stack, condenser, methanol sensor-less control and start-up characteristics. The effects of these key components and control schemes on the performance are also discussed. To expedite the use of portable DMFC in electronic applications, the system utilizes a novel methanol sensor-less control method, providing improved fuel efficiency, durability, miniaturization and cost reduction. The operating characteristics of the DMFC stack are applied to control the fuel ejection time and period, enabling the system to continue operating even when the MEAs of the stack are deteriorated. The portable system is also designed with several features including water balance and quick start-up (in 5 min). Notably, the proposed system using methanol sensor-less control with injection of pure methanol can power the DVD player and notebook PC. The system specific energy and energy density following three days of operation are 362 Wh kg{sup -1} and 335 Wh L{sup -1}, respectively, which are better than those of lithium batteries ({proportional_to}150 Wh kg{sup -1} and {proportional_to}250 Wh L{sup -}). This good energy storage feature demonstrates that the portable DMFC is likely to be valuable in computer, communication and consumer electronic (3C) markets. (author)

  1. α-sealed transfer device and portable plastic film sealers

    International Nuclear Information System (INIS)

    Fu Zhujun; Shan Ruixia

    1990-04-01

    An α transfer device which can be operated remotely is presented. The device is able to perform sealed transfer of radioactive articles from a hot cell or shielded glove box to the outside and non-radioactive articles from the outside to a hot cell or shielded glove box by using bag sealing technology. The structure of the transfer device is simple. Its operation is safe and reliable. The sealing performance of the device is very good (for alpha). The use of this transfer device will greatly reduce α contamination of the building and creates a favourable condition for operating radioactive materials in an undivided area. The portable heat sealing device is also a necessary tool in bag sealing technology and α-sealed transfer. Two types of portable plastic film sealers have been developed. Their structure is simple. The operation of the portable plastic film sealers is easy. Their performance is also excellent. Both the α-sealed transfer device and portable plastic film sealers are very useful to the reprocessing plant of nuclear fuel

  2. The applications of vehicle borne and ground gamma ray spectrometry in environmental radioactivity survey and monitoring: examples from the Philippines

    International Nuclear Information System (INIS)

    Reyes, R.Y.; Petrache, C.A.; Garcia, N.Q.; Tabora, E.U.; Juson, J.G.

    2002-01-01

    In the light of the nuclear development all over the world, there is an increasing global awareness on matters related to radioactivity and radioactive accidents. As such, the Philippine Nuclear Research Institute (PNRI) acquired through a technical cooperation project with the International Atomic Energy Agency the vehicle borne (car borne) and portable (ground) gamma ray, spectrometers. The objectives of this project were to establish environmental baseline information on the natural radioactivity of the entire country and to generate radioelement maps for geological mapping and mineral resource assessment. The purpose of this paper is to present the results of the different surveys including the methodologies and techniques conducted in the country using both spectrometers in effectively mapping natural and man-made sources of radiation. A pilot survey was successfully carried out over the small island of Marinduque (989 km 2 ) using the combined car borne and ground gamma ray spectrometric survey techniques. This was in preparation of the planned nationwide survey using this approach. Highlight of this study was the production of the first natural radioactivity maps within the country. Interestingly, these maps closely reflect the local geology of Marinduque Island. Car borne gamma ray spectrometric surveys were likewise undertaken at the former US naval base in Subic and US airforce base in Clark. This was due to mounting public concern over the presence of possible radioactive contamination or materials left behind by the US military forces in these bases. Results using the gamma-ray spectrum ratio technique indicated the absence of man-made sources of radiation in areas monitored within the two bases. A sizeable part of Metro Manila, the capital of the Philippines, has also been covered by the car borne survey. Results discovered an area with high measurements of thorium. The radiation source is coming from an establishment that uses thorium nitrate in

  3. Portable technologies at the museum

    DEFF Research Database (Denmark)

    Svabo, Connie

    2011-01-01

    A topic of interest in contemporary museum studies is how digital technologies contribute to museum visitor experiences. Building on insights from media and technology studies that new media should be understood for how they overlap with old media, the article reports an ethnographic study...... of the intersections between the exhibition at a modern museum of natural history and three portable technologies – one of which is digital. Mobile phone cameras, exercise pamphlets and dress-up costumes link visitors with an exhibition, but they simultaneously shape this relation in their own specific directions....... This is shown by drawing on the concept of mediation as it is developed by philosopher Michel Serres and philosopher of technology Bruno Latour. The article is based on the Ph.D. thesis entitled “Portable Objects at the Museum”, defended at Roskilde University on 22 September 2010....

  4. Field uses of a portable 4/6 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Schonberg, R.G.

    1987-01-01

    The portable electron linear accelerator which was developed on Electric Power Research Institute funds was targeted to provide an additional inspection tool for the nuclear power industry. The results have justified the expense in cost savings by reducing unnecessary repairs and in demonstrating integrity of some critical welds in pump bodies. The minac (miniature accelerator) has proven effective in cases where other inspection techniques have been ineffective, such as cast stainless steel pump bodies and overlay clad welds. Other applications, such as dynamic imaging of rocket motor test firings and field inspection of pressure vessels, will be reported. A description of the equipment, the method of field operation and the special safety problems related to a high intensity radiation source without containment will be discussed. (orig.)

  5. The natural horn as an efficient sound radiating system ...

    African Journals Online (AJOL)

    Results obtained showed that the locally made horn are efficient sound radiating systems and are therefore excellent for sound production in local musical renditions. These findings, in addition to the portability and low cost of the horns qualify them to be highly recommended for use in music making and for other purposes ...

  6. Development of the 'Beta-Boy' radiation counter for public acceptance activities

    International Nuclear Information System (INIS)

    Tanabe, Hiroshi; Kitada, Hiroshi

    1993-01-01

    Japan Nuclear Fuel Ltd., which was established on July 1st, 1992 largely financed by Japan's electric power companies is presently developing four projects in the village of Rokkasho, Aomori Prefecture, roughly 700 km north of Tokyo: a uranium enrichment plant, which began operation in March, 1992; a reprocessing plant to begin construction in March, 1993; a high level radioactive waste storage facility for waste returned from overseas reprocessing, construction of which began in May, 1992; and a low level radioactive waste disposal center for waste generated in nuclear power plants, which began operation in December, 1992. Approval for the location of these facilities was obtained from the authorities in Aomori Prefecture and Rokkasho Village in 1985. However, following the Chernobyl accident in 1986, the nuclear fuel cycle project in Rokkasho as well as other nuclear facilities throughout the country were faced with very active opposition from the antinuclear movement. Through our efforts to obtain public acceptance by arranging site tours, lectures, public debates and so on, we realized that many of the people of Aomori Prefecture had doubts about the nuclear fuel cycle, and that more than 80% of those people held concerns about radiation. We also found that through the demonstration of measuring atmospheric radiation levels using a large conventional portable GM survey meter of the type used in nuclear facilities, we were able to obtain considerable understanding of the nature of radiation at our lectures. Realizing therefore the need to increase this effect, we decided to develop a simple radiation counter, which all the participants at our lectures could operate themselves to measure radiation. I will now explain the characteristics of 'Beta-Boy', new radiation counter, and the method to explain radiation by using 'Beta-Boy' in our public acceptance activities

  7. The FORCE: A highly portable parallel programming language

    Science.gov (United States)

    Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

    1989-01-01

    Here, it is explained why the FORCE parallel programming language is easily portable among six different shared-memory microprocessors, and how a two-level macro preprocessor makes it possible to hide low level machine dependencies and to build machine-independent high level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared memory multiprocessor executing them.

  8. The FORCE - A highly portable parallel programming language

    Science.gov (United States)

    Jordan, Harry F.; Benten, Muhammad S.; Alaghband, Gita; Jakob, Ruediger

    1989-01-01

    This paper explains why the FORCE parallel programming language is easily portable among six different shared-memory multiprocessors, and how a two-level macro preprocessor makes it possible to hide low-level machine dependencies and to build machine-independent high-level constructs on top of them. These FORCE constructs make it possible to write portable parallel programs largely independent of the number of processes and the specific shared-memory multiprocessor executing them.

  9. Determination of alternative conditions for instruments calibration with beta radiation

    International Nuclear Information System (INIS)

    Rocha, F.D.G.; Caldas, L.V.E.

    1992-01-01

    The influence of homogenization filter in the determination of chamber calibration factors and transmission factors of beta radiation in air, for obtaining different alternative conditions for beta-gamma portable monitors calibration was studied, using an extrapolation chamber and the beta secondary system at IPEN-CNEN-Brazil. (C.G.C.)

  10. On the awareness of radiation protection. A questionnaire survey of junior college students of radiological technology

    International Nuclear Information System (INIS)

    Kayamori, Ryo; Togashi, Atsuhiko; Yamazaki, Yoshihiro; Inakoshi, Hideki

    2002-01-01

    A questionnaire survey on the awareness of radiation protection was conducted to improve our curriculum of radiation protection education, which seems to be important for the safe administrative control systems and handling techniques of radiation. A total of 426 students answered our questionnaire during the period of 1994 to 1999. They were 80 first-year, 114 second-year and 232 third-year students. The facility values of 4 questions on the influence of radiation to a human body were 50.2%, 30.3%, 28.9% and 7.0%. There was no statistically significant difference among different age groups. The facility values of 3 questions on the dose limitation of occupation exposure were 50.5% (on the effective dose equivalent), 36.4% (on the tissue dose equivalent to skin), and 40.9% (on the crystalline lens). On safe handling of radiation, only 35.7% of students correctly answered that they use a plastic board to protect themselves from β-ray, while 77.0% correctly answered the question on the decontamination method of radioactive substance from the skin. The results show the students' lack of knowledge on radiation protection. Those involved in basic science education and radiation protection education, therefore, need to clarify their teaching content and offer explicit explanations on the proper dose of radiation, effects to exposure dose, interaction between different materials and radiation. (author)

  11. The portability of the "Electronics Workbench" simulation software to China

    NARCIS (Netherlands)

    Collis, Betty; Zhi-Cheng, Dong

    1993-01-01

    This article discusses the portability of the Canadian-made simulation software package, "Electronic Workbench" package (EWB) to China. As part of a larger project investigating the portability of various educational software packages, the EWB package was used in electronics instruction in China and

  12. PORTABLE SOURCE OF RADIOACTIVITY

    Science.gov (United States)

    Goertz, R.C.; Ferguson, K.R.; Rylander, E.W.; Safranski, L.M.

    1959-06-16

    A portable source for radiogiaphy or radiotherapy is described. It consists of a Tl/sup 170/ or Co/sup 60/ source mounted in a rotatable tungsten alloy plug. The plug rotates within a brass body to positions of safety or exposure. Provision is made for reloading and carrying the device safely. (T.R.H.)

  13. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  14. Portable Weather Intelligence for the Soldier

    National Research Council Canada - National Science Library

    Sauter, David

    2008-01-01

    Enhancements in computer hardware and software technology have allowed the development and porting of advanced environmental effects applications on highly portable lightweight computing devices. The U.S...

  15. Portable EMG devices, Biofeedback and Contingent Electrical Stimulation applications in Bruxism

    DEFF Research Database (Denmark)

    Castrillon, Eduardo

    Portable EMG devices, Biofeedback and Contingent Electrical Stimulation applications in Bruxism Eduardo Enrique, Castrillon Watanabe, DDS, MSc, PhD Section of Orofacial Pain and Jaw Function, Department of Dentistry, Aarhus University, Aarhus, Denmark; Scandinavian Center for Orofacial Neuroscience...... Summary: Bruxism is a parafunctional activity, which involves the masticatory muscles and probably it is as old as human mankind. Different methods such as portable EMG devices have been proposed to diagnose and understand the pathophysiology of bruxism. Biofeedback / contingent electrical stimulation...... characteristics make it complicated to assess bruxism using portable EMG devices. The possibility to assess bruxism like EMG activity on a portable device made it possible to use biofeedback and CES approaches in order to treat / manage bruxism. The available scientific information about CES effects on bruxism...

  16. A portable nondestructive assay measurement control system

    International Nuclear Information System (INIS)

    Palmer, M.E.

    1984-01-01

    Portable nondestructive assay (NDA) of plutonium processing hoods, solvent extraction columns, glove boxes, filters, and other items is required for both nuclear materials accountability and criticality control purposes. The Plutonium Finishing Plant has hundreds of such items that require routine portable NDA measurement. Previous recordkeeping of NDA measurements consisted of boxes of papers containing results and notebooks containing notes for each item to be measured. If the notes for any item were lost, new measurement parameters had to be calculated for that item. As a result, subsequent measurements could no longer be directly compared with previous results for that item due to possible changes in measurement parameters. The new portable NDA management system keeps all the necessary information in a computerized data base. Technicians are provided with a computer-generated drawing of each item to be measured, which also contains comments, measurement points, measurement parameters, and a form for filling in the raw data. After the measurements are made, the technician uses the computer to calculate and print out the results

  17. The Patterns of Care Survey of radiation therapy in localized prostate cancer: Similarities between the practice nationally and in minority-rich areas

    International Nuclear Information System (INIS)

    Zietman, Anthony; Moughan, Jennifer; Owen, Jean; Hanks, Gerald

    2001-01-01

    Purpose: Over the last two decades, the chance for the cure of localized prostate cancer by radiation has been improved by the widespread use of PSA for early detection and by a number of technical advances in treatment delivery. This study was designed to determine whether the stage of presentation and the quality of radiation treatment delivered are comparable between Caucasian and minority patients nationally and within minority-rich areas. Methods and Materials: A random survey conducted for the Patterns of Care Study in Radiation Oncology of 80 facilities treating patients with radiation in the USA. Of these, 67 comprise the 'National Survey' and 13 a 'Minority-Rich' survey (>40% of treated patients are minorities). Nine hundred twenty-six men with localized prostate cancer were treated in 1994. Five hundred ninety-five were in the national and 331 in the minority-rich survey. The main outcome measures were the clinical features of Caucasian and minority men at presentation and technical characteristics of the treatment delivered to them. Results: African-American men presented with more advanced disease (higher-presenting PSA and T-stage) than Caucasians in both the national and the minority-rich surveys. Hispanics also presented with later disease and could be grouped with African-American men rather than Caucasians. Overall the stage and PSA at presentation was earlier than seen in the previous Patterns of Care Study survey of 1989. The quality of treatment delivered has improved since 1989, with no distinction seen between those facilities sampled nationally and those within minority-rich areas. Conclusion: African-American and Hispanic men with prostate cancer present for therapy at a later stage than Caucasian men, but when they do, the treatment received is of comparable quality

  18. A robotic system to conduct radiation and contamination surveys on nuclear waste transport casks

    International Nuclear Information System (INIS)

    Harrigan, R.W.; Sanders, T.L.

    1990-06-01

    The feasibility of performing, numerous spent fuel cask operations using fully integrated robotic systems is under evaluation. Using existing technology, operational and descriptive software and hardware in the form of robotic end effectors are being designed in conjunction with interfacing cask components. A robotic radiation and contamination survey system has been developed and used on mock-up cask hardware to evaluate the impact of such fully automated operations on cask design features and productivity. Based on experience gained from the survey system, numerous health physics operations can be reliably performed with little human intervention using a fully automated system. Such operations can also significantly reduce time requirements for cask-receiving operations. 7 refs., 51 figs., 6 tabs

  19. Radiation safety research information database

    International Nuclear Information System (INIS)

    Yukawa, Masae; Miyamoto, Kiriko; Takeda, Hiroshi; Kuroda, Noriko; Yamamoto, Kazuhiko

    2004-01-01

    National Institute of Radiological Sciences in Japan began to construct Radiation Safety Research Information Database' in 2001. The research information database is of great service to evaluate the effects of radiation on people by estimating exposure dose by determining radiation and radioactive matters in the environment. The above database (DB) consists of seven DB such as Nirs Air Borne Dust Survey DB, Nirs Environmental Tritium Survey DB, Nirs Environmental Carbon Survey DB, Environmental Radiation Levels, Abe, Metabolic Database for Assessment of Internal Dose, Graphs of Predicted Monitoring Data, and Nirs nuclear installation environment water tritium survey DB. Outline of DB and each DB are explained. (S.Y.)

  20. Optical grid alignment system for portable radiography and portable radiography apparatus incorporating same

    International Nuclear Information System (INIS)

    MacMahon, H.

    1993-01-01

    A grid alignment system is described for use in a portable radiographic apparatus for aligning x-ray film with an x-ray source within said portable radiographic apparatus, comprising: a grid cassette, movable relative to said x-ray source, including an x-ray film holding portion, an anti-scatter grid substantially fixed relative to said x-ray film holding portion and positioned between said x-ray film holding portion and said x-ray source, and a reflector element substantially fixed relative to said grid, said reflector element including a reflective surface for reflecting said incident light beam to produce a reflected light beam, and an imaging surface for producing images of said incident light beam and said reflected light beam, said images providing an indication of alignment between said grid cassette and said x-ray source; and a light beam projector substantially fixed relative to said x-ray source, said light-beam projector projecting said incident light beam upon said reflector element to provide said indication of alignment between said grid cassette and said x-ray source