WorldWideScience

Sample records for polyaxial locked implants

  1. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  2. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  3. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  4. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  5. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  6. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  7. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Sinking and fit of abutment of locking taper implant system

    Science.gov (United States)

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  9. Esthetic Outcomes of Immediately Loaded Locking Taper Implants in the Anterior Maxilla: A Case Series Study.

    Science.gov (United States)

    Lombardo, Giorgio; Corrocher, Giovanni; Pighi, Jacopo; Mascellaro, Anna; Marincola, Mauro; Nocini, Per Francesco

    2016-06-01

    The purpose of this study was to evaluate the esthetic outcome of single-tooth locking taper connection implants placed in the anterior maxilla following a postextractive nonfunctional loading protocol. This preliminary clinical study involving 16 patients evaluated the results of 21 implants placed in areas with high esthetic value. For each implant the pink esthetic score, white esthetic score, cumulative survival rate, and health status of peri-implant tissues were evaluated. The cumulative survival rate was 100% 2 years after prosthetic loading, and the mean total pink esthetic score/white esthetic score was 16.9 ± 1.14 on a maximum value of 20. There was excellent plaque control in all patients, and inflammation indices were within the norm. Within the limits of this study, this immediate nonfunctional loading protocol seems to be a successful procedure esthetically and for the maintenance of peri-implant soft tissues.

  10. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    Science.gov (United States)

    Raschke, M J; Stange, R; Kösters, C

    2012-11-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  11. Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study

    Directory of Open Access Journals (Sweden)

    Jae-Won Choi

    2018-04-01

    Full Text Available The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH, internal-octagon connection (IO, internal-hexagon connection (IH, one-body implant (OB, micro-locking implant system (ML. The maximum compressive load was measured using a universal testing machine (UTM according to the ISO 14801. Retention was evaluated in two experiments: (1 a tensile test of the structure modifications of the components (attachment and implant and (2 a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz. The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05. The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05, but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05. On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.

  12. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  13. Wide-diameter locking-taper implants: a prospective clinical study with 1 to 10-year follow-up

    Directory of Open Access Journals (Sweden)

    C. Mangano

    2014-06-01

    Full Text Available Aim: Wide-diameter implants (WDIs, diameter ≥4.5 mm are increasingly being used in patients with poor bone quality and reduced bone height. The aim of this study was to evaluate the survival rate, peri-implant bone loss, biological and prosthetic complications of wide-diameter (4.8 mm locking-taper implants used in the restoration of partially and fully edentulous patients. Materials and methods: Between January 2002 and December 2011, all patients referred to a private clinic for treatment with WDIs were considered for inclusion in the study. At each annual follow-up session, clinical and radiographic parameters were assessed: the outcome measurements were implant failure, peri-implant bone loss (distance between the implant shoulder and the first visible bone-to-implant contact: DIB, biological and prosthetic complications. The cumulative survival rate (CSR was assessed using the Kaplan-Meier estimator; Log-rank was applied to evaluate correlations between the study variables. The statistical analysis was performed at the patient and at the implant level. Results: A total of 438 WDIs were placed in 411 patients. Four implants failed, for a CSR of 99% (patient-based and 99.1% (implant-based at 10-year follow-up. The CSR did not differ significantly with respect to patients’ gender, age, smoking or parafunctional habit, implant location, position, length, bone type or prosthetic restoration. A mean DIB of 0.34 mm (± 0.23, 0.45 mm (± 0.27 and 0.75 mm (± 0.33 was shown at the 1-, 5- and 10-year follow-up examination. Conclusions: Wide-diameter, locking-taper implants can be a good treatment option for the rehabilitation of partially and fully edentulous patients over the long term.

  14. A clinical report on the use of closed tray, hex-lock-friction-fit implant impression copings.

    Science.gov (United States)

    Raviv, Eli; Hana, Jan; Raviv, Roy; Harel-Raviv, Mili

    2012-04-17

    Abstract AbstractThe precision of an impression determines the subsequent accuracy and fit of thefinal restoration. Therefore, the ultimate search is for the most accurate impressionmaterial and technique that is also the most efficient and least time consuming. One ofthe major debates in implant dentistry has been between the pick up versus the transferimpression technique. The pick up technique is widely accepted as the more accurate.However, the conventional transfer technique is simpler and less time consuming. TheHex-Lock-Friction-Fit impression coping (AB Dental Devices®) combines theadvantages of both the transfer impression technique and the pick up impressiontechnique. In this article we will review the relevant literature, discuss the advantages ofthis unique implant impression technique and present some related clinical cases.

  15. A clinical report on the use of closed-tray, hex-lock-friction-fit implant impression copings.

    Science.gov (United States)

    Raviv, Eli; Hanna, Jan; Raviv, Roy; Harel-Raviv, Mili

    2014-08-01

    The precision of an impression determines the subsequent accuracy and fit of the final restoration. Therefore, the ultimate search is for the most accurate impression material and the most efficient and least time consuming technique. One of the major debates in implant dentistry has focused on the advantages of the pick-up versus the transfer impression technique. The pick-up technique is widely accepted as the more accurate. However, the conventional transfer technique is simpler and less time consuming. The Hex-Lock-Friction-Fit impression coping (AB Dental Devices) combines the advantages of the transfer impression technique and the pick-up impression technique. In this article we will review the relevant literature, discuss the advantages of this unique implant impression technique, and present some related clinical cases.

  16. Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up.

    Science.gov (United States)

    Mangano, Francesco; Shibli, Jamil A; Sammons, Rachel L; Veronesi, Giovanni; Piattelli, Adriano; Mangano, Carlo

    2014-01-01

    To evaluate the outcome of narrow-diameter (3.3-mm) locking-taper implants used in the rehabilitation of partially and fully edentulous patients over a 10-year period. Between January 2002 and December 2011, all patients referred to a private dental clinic for treatment with narrow-diameter implants were enrolled in this study. At each annual follow-up session, clinical and radiographic parameters were assessed; the outcome measurements were implant failure, peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact [DIB]), and biologic and technical complications. The cumulative survival rate (CSR) was assessed using the Kaplan-Meier survival estimator; Tarone-Ware and chi-square analyses were used to evaluate correlations between the study variables. The statistical analysis was performed at the patient- and implant-level. A total of 324 narrow-diameter implants were placed in 279 patients (159 men, 120 women; age: 25 to 73 years). Four implants failed, for an overall CSR of 98.5% (patient-based) and 98.7% (implant-based) at the 10-year follow-up. The survival rate did not differ significantly with respect to patients' sex, age, smoking or parafunctional habits, bone type, prosthetic restoration, or implant location, position, or length. Among the surviving implants, a mean DIB of 0.31 ± 0.23 mm, 0.45 ± 0.27 mm, and 0.69 ± 0.28 mm was observed at the 1-, 5-, and 10-year follow-up examinations, respectively. A few biologic (1.2%) and technical complications (7.5%) were reported. Within the limitations of this study, it can be concluded that narrow-diameter locking-taper implants represent a good treatment option for the prosthetic rehabilitation of partially and totally edentulous patients.

  17. Fully Implanted Brain-Computer Interface in a Locked-In Patient with ALS.

    Science.gov (United States)

    Vansteensel, Mariska J; Pels, Elmar G M; Bleichner, Martin G; Branco, Mariana P; Denison, Timothy; Freudenburg, Zachary V; Gosselaar, Peter; Leinders, Sacha; Ottens, Thomas H; Van Den Boom, Max A; Van Rijen, Peter C; Aarnoutse, Erik J; Ramsey, Nick F

    2016-11-24

    Options for people with severe paralysis who have lost the ability to communicate orally are limited. We describe a method for communication in a patient with late-stage amyotrophic lateral sclerosis (ALS), involving a fully implanted brain-computer interface that consists of subdural electrodes placed over the motor cortex and a transmitter placed subcutaneously in the left side of the thorax. By attempting to move the hand on the side opposite the implanted electrodes, the patient accurately and independently controlled a computer typing program 28 weeks after electrode placement, at the equivalent of two letters per minute. The brain-computer interface offered autonomous communication that supplemented and at times supplanted the patient's eye-tracking device. (Funded by the Government of the Netherlands and the European Union; ClinicalTrials.gov number, NCT02224469 .).

  18. Acromioclavicular joint reconstruction using the LockDown synthetic implant: a study with cadavers.

    Science.gov (United States)

    Taranu, R; Rushton, P R P; Serrano-Pedraza, I; Holder, L; Wallace, W A; Candal-Couto, J J

    2015-12-01

    Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. ©2015 The British Editorial Society of Bone & Joint Surgery.

  19. Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

    Science.gov (United States)

    Manolis, Antonis S; Georgiopoulos, Georgios; Metaxa, Sofia; Koulouris, Spyridon; Tsiachris, Dimitris

    2017-10-01

    We have previously reported our successful approach for percutaneous cardiac implantable electronic device (CIED) lead extraction using inexpensive tools, which we have continued over the years. Herein we report the results of the systematic use of a unique stylet, the lead-locking device (LLD), which securely locks the entire lead lumen, aided with non-powered telescoping sheaths in 54 patients to extract 98 CIED leads. This prospective observational clinical study included 38 men and 16 women aged 68.9±13.1 years undergoing lead extraction for device infection (n=46), lead malfunction (n=5), or prior to defibrillator implant (n=3). Leads were in place for 6.7±4.3 years. Infections were more commonly due to Staphylococcus species (n=40). There were 78 pacing (31 ventricular, 37 atrial, 4 VDD, and 6 coronary sinus leads) and 20 defibrillating leads. Using simple traction (6 leads) and the LLD stylets (92 leads) aided with telescoping sheaths (15 patients), 96 (98%) leads in 52 (96.3%) patients were successfully removed, with all but one leads removed using a subclavian approach; in 1 patient, the right femoral approach was also required. In 2 patients, distal fragments from one ventricular pacing and one defibrillating lead could not be removed. Finally, lead removal was completely (52/54) (96.3%) or partially (2/54) (3.7%) successful in 54 patients for 96 of 98 leads (98%) without major complications. Percutaneous lead extraction can be successful with mechanical tools using the LLD locking stylet aided with non-powered telescoping sheaths through a simplified, safe, and inexpensive procedure using local anesthesia.

  20. Polyaxial stress-dependent permeability of a three-dimensional fractured rock layer

    Science.gov (United States)

    Lei, Qinghua; Wang, Xiaoguang; Xiang, Jiansheng; Latham, John-Paul

    2017-12-01

    A study about the influence of polyaxial (true-triaxial) stresses on the permeability of a three-dimensional (3D) fractured rock layer is presented. The 3D fracture system is constructed by extruding a two-dimensional (2D) outcrop pattern of a limestone bed that exhibits a ladder structure consisting of a "through-going" joint set abutted by later-stage short fractures. Geomechanical behaviour of the 3D fractured rock in response to in-situ stresses is modelled by the finite-discrete element method, which can capture the deformation of matrix blocks, variation of stress fields, reactivation of pre-existing rough fractures and propagation of new cracks. A series of numerical simulations is designed to load the fractured rock using various polyaxial in-situ stresses and the stress-dependent flow properties are further calculated. The fractured layer tends to exhibit stronger flow localisation and higher equivalent permeability as the far-field stress ratio is increased and the stress field is rotated such that fractures are preferentially oriented for shearing. The shear dilation of pre-existing fractures has dominant effects on flow localisation in the system, while the propagation of new fractures has minor impacts. The role of the overburden stress suggests that the conventional 2D analysis that neglects the effect of the out-of-plane stress (perpendicular to the bedding interface) may provide indicative approximations but not fully capture the polyaxial stress-dependent fracture network behaviour. The results of this study have important implications for understanding the heterogeneous flow of geological fluids (e.g. groundwater, petroleum) in subsurface and upscaling permeability for large-scale assessments.

  1. A 65nm CMOS low-power MedRadio-band integer-N cascaded phase-locked loop for implantable medical systems.

    Science.gov (United States)

    Wang, Yi-Xiao; Chen, Wei-Ming; Wu, Chung-Yu

    2014-01-01

    This paper presents a low-power MedRadio-band integer-N phase-locked Loop (PLL) system which is composed of two charge-pump PLLs cascade connected. The PLL provides the operation clock and local carrier signals for an implantable medical electronic system. In addition, to avoid the off-chip crystal oscillator, the 13.56 MHz Industrial, Scientific and Medical (ISM) band signal from the wireless power transmission system is adopted as the input reference signal for the PLL. Ring-based voltage controlled oscillators (VCOs) with current control units are adopted to reduce chip area and power dissipation. The proposed cascaded PLL system is designed and implemented in TSMC 65-nm CMOS technology. The measured jitter for 216.96 MHz signal is 12.23 ps and the phase noise is -65.9 dBc/Hz at 100 kHz frequency offset under 402.926 MHz carrier frequency. The measured power dissipations are 66 μW in the first PLL and 195 μW in the whole system under 1-V supply voltage. The chip area is 0.1088 mm(2) and no off-chip component is required which is suitable for the integration of the implantable medical electronic system.

  2. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  3. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  4. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    Directory of Open Access Journals (Sweden)

    Lutz Weise

    2008-10-01

    Full Text Available Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker. The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326. In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more was 3.37% (11/326. Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation

  5. Faulting of rocks in three-dimensional strain fields I. Failure of rocks in polyaxial, servo-control experiments

    Science.gov (United States)

    Reches, Ze'ev; Dieterich, James H.

    1983-05-01

    The dependence of the number of sets of faults and their orientation on the intermediate strain axis is investigated through polyaxial tests, reported here, and theoretical analysis, reported in an accompanying paper. In the experiments, cubic samples of Berea sandstone, Sierra-White and Westerly granites, and Candoro and Solnhofen limestones were loaded on their three pairs of faces by three independent, mutually perpendicular presses at room temperature. Two of the presses were servo-controlled and applied constant displacement rates throughout the experiment. Most samples display three or four sets of faults in orthorhombic symmetry. These faults form in several yielding events that follow a stage of elastic deformation. In many experiments, the maximum and the intermediate compressive stresses interchange orientations during the yielding events, where the corresponding strains are constant. The final stage of most experiments is characterized by slip along the faults.

  6. Faulting of rocks in three-dimensional strain fields I. Failure of rocks in polyaxial, servo-control experiments

    Science.gov (United States)

    Reches, Z.; Dieterich, J.H.

    1983-01-01

    The dependence of the number of sets of faults and their orientation on the intermediate strain axis is investigated through polyaxial tests, reported here, and theoretical analysis, reported in an accompanying paper. In the experiments, cubic samples of Berea sandstone, Sierra-White and Westerly granites, and Candoro and Solnhofen limestones were loaded on their three pairs of faces by three independent, mutually perpendicular presses at room temperature. Two of the presses were servo-controlled and applied constant displacement rates throughout the experiment. Most samples display three or four sets of faults in orthorhombic symmetry. These faults form in several yielding events that follow a stage of elastic deformation. In many experiments, the maximum and the intermediate compressive stresses interchange orientations during the yielding events, where the corresponding strains are constant. The final stage of most experiments is characterized by slip along the faults. ?? 1983.

  7. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation – initial evaluation in cortex cerebri of awake rats

    Directory of Open Access Journals (Sweden)

    Johan eAgorelius

    2015-09-01

    Full Text Available A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals.MethodsAn array of eight separated gold leads (4 x10 μm, individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array.ResultsMedian noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3 μV to 5.9 μV and 2.8 to 4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 V. In addition, high correlations (>0.96 between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation.Conclusions A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various

  8. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  10. Bicycle Parking and Locking

    DEFF Research Database (Denmark)

    Larsen, Jonas

    2017-01-01

    . This article contributes with new insights into parking and locking - ‘moorings’ - to cycling literature. It presents an ethnography of ‘design moorings’ and practices associated with parking and locking bikes. The main case study is the very pro-cycling city of Copenhagen. Yet to explore what is unique about...

  11. ''Old'' locked inflation

    International Nuclear Information System (INIS)

    Liu, Yang; Piao, Yun-Song; Si, Zong-Guo

    2009-01-01

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' φ. Instead of rolling down along the potential, the φ field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape

  12. Quantum noise locking

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Mikhailov, Eugeniy E; Goda, Keisuke; Lam, Ping Koy; Grosse, Nicolai; Gray, Malcolm B; Mavalvala, Nergis; McClelland, David E

    2005-01-01

    Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, cannot rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector

  13. LOCKS AND KEYS SERVICE

    CERN Multimedia

    Locks and Keys Service

    2002-01-01

    The Locks and Keys service (ST/FM) will move from building 55 to building 570 from the 2nd August to the 9th August 2002 included. During this period the service will be closed. Only in case of extreme urgency please call the 164550. Starting from Monday, 12th August, the Locks and Keys Service will continue to follow the activities related to office keys (keys and locks) and will provide the keys for furniture. The service is open from 8h30 to 12h00 and from 13h00 to 17h30. We remind you that your divisional correspondents can help you in the execution of the procedures. We thank you for your comprehension and we remain at your service to help you in solving all the matters related to keys for offices and furniture. Locks and Keys Service - ST Division - FM Group

  14. Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Voergård Rasmussen, Katrine Marie; Overgaard, Søren

    2017-01-01

    Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between biomecha......Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between...

  15. Locke and botany.

    Science.gov (United States)

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  16. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  17. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  18. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  19. Risk of infection due to medical interventions via central venous catheters or implantable venous access port systems at the middle port of a three-way cock: luer lock cap vs. luer access split septum system (Q-Syte).

    Science.gov (United States)

    Pohl, Fabian; Hartmann, Werner; Holzmann, Thomas; Gensicke, Sandra; Kölbl, Oliver; Hautmann, Matthias G

    2014-01-25

    Many cancer patients receive a central venous catheter or port system prior to therapy to assure correct drug administration. Even appropriate hygienic intervention maintenance carries the risk of contaminating the middle port (C-port) of a three-way cock (TWC), a risk that increases with the number of medical interventions. Because of the complexity of the cleaning procedure with disconnection and reconnection of the standard luer lock cap (referred as "intervention"), we compared luer lock caps with a "closed access system" consisting of a luer access split septum system with regard to process optimization (work simplification, process time), efficiency (costs) and hygiene (patient safety). For determination of process optimization the workflow of an intervention according to the usual practice and risks was depicted in a process diagram. For determining the actual process costs, we analyzed use of material and time parameters per intervention and used the process parameters for programming the process into a simulation run (n = 1000) to determine the process costs as well as their differences (ACTUAL vs. NOMINAL) within the framework of a discrete event simulation.Additionally cultures were carried out at the TWC C-ports to evaluate possible contamination. With the closed access system, the mean working time of 5.5 minutes could be reduced to 2.97 minutes. The results for average process costs (labour and material costs per use) were 3.92 € for luer lock caps and 2.55 € for the closed access system. The hypothesis test (2-sample t-test, CI 0.95, p-valuerisks (related to material, surroundings, staff handling) could be reduced by 65.38%. In the present research, the closed access system with a divided split septum was superior to conventional luer lock caps. The advantage of the closed access system lies in the simplified handling for staff, which results in a reduced risk of patient infection due to improved clinical hygiene.

  20. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  1. Locked nucleic acid

    DEFF Research Database (Denmark)

    Jepsen, Jan Stenvang; Sørensen, Mads D; Wengel, Jesper

    2004-01-01

    Locked nucleic acid (LNA) is a class of nucleic acid analogs possessing very high affinity and excellent specificity toward complementary DNA and RNA, and LNA oligonucleotides have been applied as antisense molecules both in vitro and in vivo. In this review, we briefly describe the basic...

  2. Roller Locking Brake

    Science.gov (United States)

    Vranish, John M.

    1993-01-01

    Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

  3. Locks and Keys Service

    CERN Multimedia

    Claude Ducastel

    The GS-LS-SEM section is pleased to inform you that as from Monday 30 November 2009, the opening hours of the Locks and Keys service will be the following: 08h30 - 12h30 / 13h30 - 16:30, Mondays to Fridays. GS-SEM-LS 73333

  4. Innovation and Lock-in

    DEFF Research Database (Denmark)

    Cantner, Uwe; Vannuccini, Simone

    2016-01-01

    This study focuses on a well-known but yet elusive concept: (technological) lock-in. We summarize what is known about the nature of lock-in and offer a critical view on history-dependent processes based on recent contributions to the literature. We discuss if lock-ins are really inescapable......, especially when innovation is concerned. Also, we address the question if lock-in is a well-defined concept at all. To offer a fresh view on lock-in and to tackle the issues just raised, we employ the replicator dynamics model. By making a parallel between monopolization in the replicator dynamics...... and the occurrence of lock-ins, we show that the convergence of a system to a given outcome can be reversed, under certain conditions. We highlight the need for a more precise demarcation of the conceptual boundaries of lock-in and path dependence, both from the formal and the empirical side, and suggest...

  5. Data port security lock

    Science.gov (United States)

    Quinby, Joseph D [Albuquerque, NM; Hall, Clarence S [Albuquerque, NM

    2008-06-24

    In a security apparatus for securing an electrical connector, a plug may be fitted for insertion into a connector receptacle compliant with a connector standard. The plug has at least one aperture adapted to engage at least one latch in the connector receptacle. An engagement member is adapted to partially extend through at least one aperture and lock to at least one structure within the connector receptacle.

  6. Avoiding lock-in

    DEFF Research Database (Denmark)

    Henriksen, Ingrid

    1999-01-01

    The paper investigates the initial phase of the cooperative organisation of agricultural processing firms in Denmark. It argues that the variations observed can be explained within the framework of the theory of industrial organisation. The focus is on the success of cooperative creameries. In 19...... of gathering information and of preserving and transporting a perishable product, were ideally suited to overcome the problems of potential lock-in and of asymmetric information...

  7. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Science.gov (United States)

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  8. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  9. Breaking Carbon Lock-in

    DEFF Research Database (Denmark)

    Driscoll, Patrick Arthur

    2014-01-01

    This central focus of this paper is to highlight the ways in which path dependencies and increasing returns (network effects) serve to reinforce carbon lock-in in large-scale road transportation infrastructure projects. Breaking carbon lock-in requires drastic changes in the way we plan future...

  10. Homodyne locking of a squeezer.

    Science.gov (United States)

    Heurs, M; Petersen, I R; James, M R; Huntington, E H

    2009-08-15

    We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.

  11. Payload Launch Lock Mechanism

    Science.gov (United States)

    Young, Ken (Inventor); Hindle, Timothy (Inventor)

    2014-01-01

    A payload launch lock mechanism includes a base, a preload clamp, a fastener, and a shape memory alloy (SMA) actuator. The preload clamp is configured to releasibly restrain a payload. The fastener extends, along an axis, through the preload clamp and into the base, and supplies a force to the preload clamp sufficient to restrain the payload. The SMA actuator is disposed between the base and the clamp. The SMA actuator is adapted to receive electrical current and is configured, upon receipt of the electrical current, to supply a force that causes the fastener to elongate without fracturing. The preload clamp, in response to the fastener elongation, either rotates or pivots to thereby release the payload.

  12. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  13. 49 CFR 236.765 - Locking, mechanical.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  14. Escaping carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, G.C.

    2002-01-01

    This article explores the climate policy implications of the arguments made in ''Understanding carbon lock-in'' (Unruh, 2000), which posited that industrial countries have become locked-into fossil fuel-based energy systems through path dependent processes driven by increasing returns to scale. Carbon lock-in arises through technological, organizational, social and institutional co-evolution, ''culminating'' in what was termed as techno-institutional complex (TIC). In order to resolve the climate problem, an escape from the lock-in condition is required. However, due to the self-referential nature of TIC, escape conditions are unlikely to be generated internally and it is argued here that erogenous forces are probably required. (author)

  15. Globalizing carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, Gregory C.; Carrillo-Hermosilla, Javier

    2006-01-01

    This paper extends the arguments surrounding carbon lock-in elaborated in Unruh (Energy Policy 28 (2000) 817; 30 (2002) 317) to countries currently undergoing industrialization. It argues that, for numerous reasons, industrializing countries are unlikely to leapfrog carbon intensive energy development. On the contrary, carbon lock-in may be globalizing and could further constrain climate change mitigation options. It is then argued that many policy recommendations ignore carbon lock-in, possibly limiting their potential for successful implementation. The paper then discusses four policy approaches that appear to have advantages given lock-in conditions. It is recognized, however, that relative ease of implementation does not necessarily equate with superiority. Instead, it is merely a path dependent outcome of past development decisions. Pursuing policies on the basis of relative implementation ease may help address the issue of climate change, but could also result in sub-optimal outcomes along other dimensions of sustainable development

  16. Research of mechanism of density lock

    International Nuclear Information System (INIS)

    Wang Shengfei; Yan Changqi; Gu Haifeng

    2010-01-01

    Mechanism of density lock was analyzed according to the work conditions of density lock. The results showed that: the stratification with no disturbance satisfied the work conditions of density lock; fluids between the stratification were not mixed at the condition of connected to each other; the density lock can be open automatically by controlled the pressure balance at the stratification. When disturbance existed, the stratification might be broken and mass would be transferred by convection. The stability of stratification can be enhanced by put the special structure in density lock to ensure the normal work of density lock. At last, the minimum of heat loss in density lock was also analyzed. (authors)

  17. Hew Locke: House of Cards

    OpenAIRE

    Reckitt, Helena; Joyce, Julie; Locke, Hew

    2004-01-01

    ‘Hew Locke: House of Cards’ featured a selection of the artist's portraits of British royalty in various media, and his response to other trappings of the monarchy and empire. The show included works previously exhibited at the Luckman Gallery, Los Angeles, in tandem with a newly commissioned coat of arms, and other recent works. \\ud \\ud Locke draws from everyday sources, ranging from items found in London's Brixton Market to discount fabric shops and thrift stores. Other sources of inspirati...

  18. John locke on personal identity.

    Science.gov (United States)

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  19. John Locke on Personal Identity**

    OpenAIRE

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  20. Biomechanics of far cortical locking.

    Science.gov (United States)

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  1. Outdraft at Lock Approach, Tom Bevill Lock and Dam, Alabama: Hydraulic Model Investigation

    National Research Council Canada - National Science Library

    Lynch, Gary

    2001-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  2. Assessing carbon lock-in

    International Nuclear Information System (INIS)

    Erickson, Peter; Kartha, Sivan; Lazarus, Michael; Tempest, Kevin

    2015-01-01

    The term ‘carbon lock-in’ refers to the tendency for certain carbon-intensive technological systems to persist over time, ‘locking out’ lower-carbon alternatives, and owing to a combination of linked technical, economic, and institutional factors. These technologies may be costly to build, but relatively inexpensive to operate and, over time, they reinforce political, market, and social factors that make it difficult to move away from, or ‘unlock’ them. As a result, by investing in assets prone to lock-in, planners and investors restrict future flexibility and increase the costs of achieving agreed climate protection goals. Here, we develop a straight-forward approach to assess the speed, strength, and scale of carbon lock-in for major energy-consuming assets in the power, buildings, industry, and transport sectors. We pilot the approach at the global level, finding that carbon lock-in is greatest, globally, for coal power plants, gas power plants, and oil-based vehicles. The approach can be readily applied at the national or regional scale, and may be of particular relevance to policymakers interested in enhancing flexibility in their jurisdictions for deeper emissions cuts in the future, and therefore in limiting the future costs associated with ‘stranded assets’. (letter)

  3. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  4. Coupled optical resonance laser locking.

    Science.gov (United States)

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  5. Automatic locking knee brace joint

    Science.gov (United States)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  6. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  7. The variable finesse locking technique

    International Nuclear Information System (INIS)

    Acernese, F; Al-Shourbagy, M

    2006-01-01

    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

  8. Coupled optical resonance laser locking

    CSIR Research Space (South Africa)

    Burd, CC

    2014-10-01

    Full Text Available We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different...

  9. Advances phase-lock techniques

    CERN Document Server

    Crawford, James A

    2008-01-01

    From cellphones to micrprocessors, to GPS navigation, phase-lock techniques are utilized in most all modern electronic devices. This high-level book takes a systems-level perspective, rather than circuit-level, which differentiates it from other books in the field.

  10. 49 CFR 236.705 - Bar, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Bar, locking. 236.705 Section 236.705..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.705 Bar, locking. A bar in an interlocking machine to which the locking dogs are attached. ...

  11. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  12. 49 CFR 236.761 - Locking, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  13. 49 CFR 236.105 - Electric lock.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  14. 49 CFR 236.757 - Lock, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  15. 49 CFR 236.768 - Locking, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  16. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-12-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  17. 49 CFR 236.766 - Locking, movable bridge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  18. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  19. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  20. Is John Locke a democrat?

    DEFF Research Database (Denmark)

    Svensson, Palle

      Over recent years there has been a tendency to present John Locke as an equalitarian democrat (Ashcraft) and being close to the political views of the levellers (Waldron). This is not a completely new interpretation (Kendall, 1941), but contrasts with the prevalent view presented in textbooks (......, criteria for a democratic process, and the institutions of polyarchy. The conclusion has implications for the relationship between political liberalism and constitutionalism on the one hand and democracy on the other....

  1. Phase-locked Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1991-01-01

    Detailed experimental characterization of the phase-locking at both DC and at microwave frequencies is presented for two closely spaced Josephson soliton (fluxon) oscillators. In the phase-locked state, the radiated microwave power exhibited an effective gain. With one common bias source......, a frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. The interacting soliton oscillators were modeled by two inductively coupled nonlinear transmission lines...

  2. Microcontroller-based locking in optics experiments

    International Nuclear Information System (INIS)

    Huang, K.; Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J.

    2014-01-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments

  3. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  4. Phase locking between Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1990-01-01

    We report observations of phase-locking phenomena between two Josephson soliton (fluxon) oscillators biased in self-resonant modes. The locking strength was measured as a function of bias conditions. A frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. Two coupled...... perturbed sine-Gordon equations were derived from an equivalent circuit consisting of inductively coupled, nonlinear, lossy transmission lines. These equations were solved numerically to find the locking regions. Good qualitative agreement was found between the experimental results and the calculations...

  5. Microcontroller-based locking in optics experiments.

    Science.gov (United States)

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  6. Microcontroller-based locking in optics experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, K. [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France); State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062 (China); Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J., E-mail: julien.laurat@upmc.fr [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France)

    2014-12-15

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  7. Double pass locking and spatial mode locking for gravitational wave detectors

    CERN Document Server

    Cusack, B J; Slagmolen, B; Vine, G D; Gray, M B; McClelland, D E

    2002-01-01

    We present novel techniques for overcoming problems relating to the use of high-power lasers in mode cleaner cavities for second generation laser interferometric gravitational wave detectors. Rearranging the optical components into a double pass locking regime can help to protect locking detectors from damage. Modulator thermal lensing can be avoided by using a modulation-free technique such as tilt locking, or its recently developed cousin, flip locking.

  8. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  9. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    . In this paper, we compare a lock-free implementation of a priority queue with a lock-based implementation. We perform experiments with processors of different generations and observe large performance differences for lock-free data structures depending on the processor generation. The lock-free implementation...... performs much better on the most recent processor generation. We investigate this performance trend, using a set of micro-benchmarks and show a significant difference in the overhead of atomic operations between processor generations. The lock-free implementation executes approximately three times as many...

  10. Past, Present, Future Erosion at Locke Island

    Energy Technology Data Exchange (ETDEWEB)

    Bjornstad, Bruce N.

    2006-08-08

    This report describes and documents the erosion that has occurred along the northeast side of Locke Island over the last 10 to 20 years. The principal cause of this erosion is the massive Locke Island landslide complex opposite the Columbia River along the White Bluffs, which constricts the flow of the river and deflects the river's thalweg southward against the island.

  11. An automatic mode-locked system for passively mode-locked fiber laser

    Science.gov (United States)

    Li, Sha; Xu, Jun; Chen, Guoliang; Mei, Li; Yi, Bo

    2013-12-01

    This paper designs and implements one kind of automatic mode-locked system. It can adjust a passively mode-locked fiber laser to keep steady mode-locked states automatically. So the unsteadiness of traditional passively mode-locked fiber laser can be avoided. The system transforms optical signals into electrical pulse signals and sends them into MCU after processing. MCU calculates the frequency of the signals and judges the state of the output based on a quick judgment algorithm. A high-speed comparator is used to check the signals and the comparison voltage can be adjusted to improve the measuring accuracy. Then by controlling two polarization controllers at an angle of 45degrees to each other, MCU extrudes the optical fibers to change the polarization until it gets proper mode-locked output. So the system can continuously monitor the output signal and get it back to mode-locked states quickly and automatically. States of the system can be displayed on the LCD and PC. The parameters of the steady mode-locked states can be stored into an EEPROM so that the system will get into mode-locked states immediately next time. Actual experiments showed that, for a 6.238MHz passively mode-locked fiber lasers, the system can get into steady mode-locked states automatically in less than 90s after starting the system. The expected lock time can be reduced to less than 20s after follow up improvements.

  12. Commonwealth Edison Company pressure locking test report

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.; Kelly, J.F.

    1996-12-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology.

  13. Commonwealth Edison Company pressure locking test report

    International Nuclear Information System (INIS)

    Bunte, B.D.; Kelly, J.F.

    1996-01-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology

  14. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  15. Neglected locked vertical patellar dislocation

    Science.gov (United States)

    Gupta, Rakesh Kumar; Gupta, Vinay; Sangwan, Sukhbir Singh; Kamboj, Pradeep

    2012-01-01

    Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge. PMID:23162154

  16. Neglected locked vertical patellar dislocation

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Gupta

    2012-01-01

    Full Text Available Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge.

  17. Unusual Cause of Knee Locking

    Directory of Open Access Journals (Sweden)

    Gazi Huri

    2013-01-01

    Full Text Available We report a case of partial intrasubstance tear of popliteus tendon as an unusual cause of pseudolocking of the knee. A 13-year-old semiprofessional soccer player applied to our clinic with a locked right knee in spite of the therapy applied (cold pack, NSAID, and immobilization in another institution 20 days after the injury. Significant extension loss was observed in his right knee with 30∘–90∘ ROM. Magnetic resonance imaging (MRI and arthroscopy confirmed the intrasubstance tear of popliteus tendon and synovitis. The ruptured part of the tendon was debrided, and the inflammatory tissue around the tendon, which may lead to pseudolocking, was gently removed with a shaver in order to regain the normal ROM. The patient was discharged with full ROM and weight bearing first day after the surgery. To our knowledge, this is the first case demonstrating intrasubstance tear of popliteus tendon causing pseudolocking of the knee.

  18. No Snowball on Habitable Tidally Locked Planets

    Science.gov (United States)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  19. No Snowball on Habitable Tidally Locked Planets

    Energy Technology Data Exchange (ETDEWEB)

    Checlair, Jade; Abbot, Dorian S. [Department of the Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, IL 60637 (United States); Menou, Kristen, E-mail: jadecheclair@uchicago.edu [Centre for Planetary Sciences, Department of Physical and Environmental Sciences, University of Toronto at Scarborough, Toronto, ON M1C 1A4 (Canada)

    2017-08-20

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO{sub 2} outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  20. No Snowball on Habitable Tidally Locked Planets

    International Nuclear Information System (INIS)

    Checlair, Jade; Abbot, Dorian S.; Menou, Kristen

    2017-01-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO 2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  1. Correlations between locked modes and impurity influxes

    Energy Technology Data Exchange (ETDEWEB)

    Fishpool, G M [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Lawson, K D [UKAEA Culham Lab., Abingdon (United Kingdom)

    1994-07-01

    An analysis of pulses that were disturbed by medium Z impurity influxes (Cl, Cr, Fe and Ni) recorded during the 91/92 JET operations, has demonstrated that such influxes can result in MHD modes which subsequently ``lock``. A correlation is found between the power radiated by the influx and the time difference between the start of the influx and the beginning of the locked mode. The growth in the amplitude of the locked mode itself can lead to further impurity influxes. A correlation is noted between intense influxes (superior to 10 MW) and the mode ``unlocking``. (authors). 4 refs., 4 figs.

  2. The Advanced Thread-Locking Mechanism

    Science.gov (United States)

    Weiss, Wolfgang

    2005-12-01

    Locking of threaded members is accomplished by a wide variety of engineering solutions. Generally, in terms of separate locking devices or by built-in locking features such as friction generating means.In regard of space flight vehicles, threaded joints are subject to severe vibration loads during launch, maneuvering, and reentry. This requires fastening systems which are capable to join structural members and attach accessories or equipment in a secure manner. However, manned spacecraft and especially payload components will be subject to installation activity during orbital or interstellar flight maintenance, repair, or mission modification. This, in turn, requires fast separation and engaging of the concerned fasteners, yet providing performance characteristics for high reliable and safe joints.The further described Advanced Thread Locking Mechanism (ATLM) has been developed to combine the merits of both, safe joining technique and a fast installation process. The ATLM uses a freewheel which is securely installed in one part of the threaded member and releasable coupled with the engaged counterpart. While screwing the threaded members together, once coupled, the freewheel will allow free mating of the threaded members including torquing to the desired value. The moment, the pair of threaded fasteners is forced to unscrew (by intended or unintended occurrence of torque in the undoing direction) the freewheel does lock instantly. Disengaging the coupling between the members of the threaded joint takes a separate release action.Owing to the nature of the ATLM, there are a number of design variants ready for implementation.Threaded fasteners in ATLM design are highly recommended for mechanical joints subject to fastening and unfastening during Extra Vehicular Activity (EVA) in course of space flight operations. This is justified through:1. Threaded members mate free running, thus, torque values preset at the wrenching tool are not influenced by varying prevailing

  3. The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey.

    Science.gov (United States)

    Wasterlain, Amy S; Melamed, Eitan; Bello, Ricardo; Karia, Raj; Capo, John T

    2017-08-01

    Surgical costs are under scrutiny and surgeons are being held increasingly responsible for cost containment. In some instances, implants are the largest component of total procedure cost, yet previous studies reveal that surgeons' knowledge of implant prices is poor. Our study aims to (1) understand drivers behind implant selection and (2) assess whether educating surgeons about implant costs affects implant selection. We surveyed 226 orthopedic surgeons across 6 continents. The survey presented 8 clinical cases of upper extremity fractures with history, radiographs, and implant options. Surgeons were randomized to receive either a version with each implant's average selling price ("price-aware" group), or a version without prices ("price-naïve" group). Surgeons selected a surgical implant and ranked factors affecting implant choice. Descriptive statistics and univariate, multivariable, and subgroup analyses were performed. For cases offering implants within the same class (eg, volar locking plates), price-awareness reduced implant cost by 9% to 11%. When offered different models of distal radius volar locking plates, 25% of price-naïve surgeons selected the most expensive plate compared with only 7% of price-aware surgeons. For cases offering different classes of implants (eg, plate vs external fixator), there was no difference in implant choice between price-aware and price-naïve surgeons. Familiarity with the implant was the most common reason for choosing an implant in both groups (35% vs 46%). Price-aware surgeons were more likely to rank cost as a factor (29% vs 21%). Price awareness significantly influences surgeons' choice of a specific model within the same implant class. Merely including prices with a list of implants leads surgeons to select less expensive implants. This implies that an untapped opportunity exists to reduce surgical expenditures simply by enhancing surgeons' cost awareness. Economic/Decision Analyses I. Copyright © 2017 American

  4. The Clinical and Economic Impact of Generic Locking Plate Utilization at a Level II Trauma Center.

    Science.gov (United States)

    Mcphillamy, Austin; Gurnea, Taylor P; Moody, Alastair E; Kurnik, Christopher G; Lu, Minggen

    2016-12-01

    In today's climate of cost containment and fiscal responsibility, generic implant alternatives represent an interesting area of untapped resources. As patents have expired on many commonly used trauma implants, generic alternatives have recently become available from a variety of sources. The purpose of this study was to examine the clinical and economic impact of a cost containment program using high quality, generic orthopaedic locking plates. The implants available for study were anatomically precontoured plates for the clavicle, proximal humerus, distal radius, proximal tibia, distal tibia, and distal fibula. Retrospective review. Level II Trauma center. 828 adult patients with operatively managed clavicle, proximal humerus, distal radius, proximal tibia, tibial pilon, and ankle fractures. Operative treatment with conventional or generic implants. The 414 patients treated with generic implants were compared with 414 patients treated with conventional implants. There were no significant differences in age, sex, presence of diabetes, smoking history or fracture type between the generic and conventional groups. No difference in operative time, estimated blood loss or intraoperative complication rate was observed. No increase in postoperative infection rate, hardware failure, hardware loosening, malunion, nonunion or need for hardware removal was noted. Overall, our hospital realized a 56% reduction in implant costs, an average savings of $1197 per case, and a total savings of $458,080 for the study period. Use of generic orthopaedic implants has been successful at our institution, providing equivalent clinical outcomes while significantly reducing implant expenditures. Based on our data, the use of generic implants has the potential to markedly reduce operative costs as long as quality products are used. Therapeutic Level III.

  5. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  6. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  7. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  8. Optical double-locked semiconductor lasers

    Science.gov (United States)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  9. Improving generalized inverted index lock wait times

    Science.gov (United States)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  10. Automatic NMR field-frequency lock-pulsed phase locked loop approach.

    Science.gov (United States)

    Kan, S; Gonord, P; Fan, M; Sauzade, M; Courtieu, J

    1978-06-01

    A self-contained deuterium frequency-field lock scheme for a high-resolution NMR spectrometer is described. It is based on phase locked loop techniques in which the free induction decay signal behaves as a voltage-controlled oscillator. By pulsing the spins at an offset frequency of a few hundred hertz and using a digital phase-frequency discriminator this method not only eliminates the usual phase, rf power, offset adjustments needed in conventional lock systems but also possesses the automatic pull-in characteristics that dispense with the use of field sweeps to locate the NMR line prior to closure of the lock loop.

  11. Interband optical pulse injection locking of quantum dot mode-locked semiconductor laser.

    Science.gov (United States)

    Kim, Jimyung; Delfyett, Peter J

    2008-07-21

    We experimentally demonstrate optical clock recovery from quantum dot mode-locked semiconductor lasers by interband optical pulse injection locking. The passively mode-locked slave laser oscillating on the ground state or the first excited state transition is locked through the injection of optical pulses generated via the opposite transition bands, i.e. the first excited state or the ground state transition from the hybridly mode-locked master laser, respectively. When an optical pulse train generated via the first excited state from the master laser is injected to the slave laser oscillating via ground state, the slave laser shows an asymmetric locking bandwidth around the nominal repetition rate of the slave laser. In the reverse injection case of, i.e. the ground state (master laser) to the first excited state (slave laser), the slave laser does not lock even though both lasers oscillate at the same cavity frequency. In this case, the slave laser only locks to higher injection rates as compared to its own nominal repetition rate, and also shows a large locking bandwidth of 6.7 MHz.

  12. QPSK regeneration without active phase-locking

    DEFF Research Database (Denmark)

    Kjøller, Niels-Kristian; Da Ros, Francesco; Røge, Kasper Meldgaard

    2016-01-01

    QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal.......QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal....

  13. Automatic locking orthotic knee device

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  14. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  15. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  16. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  17. Computation of the lock-in ranges of phase-locked loops with PI filter

    OpenAIRE

    Aleksandrov, Konstantin D.; Kuznetsov, Nikolay; Leonov, Gennady A.; Neittaanmäki, Pekka; Yuldashev, Marat V.; Yuldashev, Renat V.

    2016-01-01

    In the present work the lock-in range of PLL-based circuits with proportionallyintegrating filter and sinusoidal phase-detector characteristics are studied. Considered circuits have sinusoidal phase detector characteristics. Analytical approach based on the methods of phase plane analysis is applied to estimate the lock-in ranges of the circuits under consideration. Obtained analytical results are compared with simulation results.

  18. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  19. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  20. Universal spin-momentum locked optical forces

    Energy Technology Data Exchange (ETDEWEB)

    Kalhor, Farid [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Thundat, Thomas [Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Jacob, Zubin, E-mail: zjacob@purdue.edu [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Birck Nanotechnology Center, Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47906 (United States)

    2016-02-08

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, the direction of decay, and the direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and HE{sub 11} mode of an optical fiber. Furthermore, we explain how the recently reported phenomena of lateral optical force on chiral and achiral particles are caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from the well-known orbital angular momentum of light. Our work presents a unified view on spin-momentum locking and how it affects optical forces on chiral and achiral particles.

  1. A novel mode-locking technique

    International Nuclear Information System (INIS)

    Chen Shaoh; Chen Youming; Chen Taolue; Si Xiangdong; Yang Yi; Deng Ximing

    1993-01-01

    A novel mode-locked Nd:YAG oscillator has been developed by using an ultrafast photoconductive feedback controlled loop, and mode-locked pulses with a duration of 100ps have been obtained. The energy instability of the pulse trains is ±5%. In this type of mode-locking technology, a type of deep-level doped GaAs (Cr-doped) photoconductive switch, which has a fast response in time and is free of avalance process, is used to drive a Pockels' cell to realize mode-locking. The dark resistance of this type of photoconductive switch is 6 orders of magnitude higher than that of the intrinsic single-crystal silicon, and it can reach a level as high as 10 9 ohms. Consequently, it is able to withstand longterm operation at several thousand DC volts. By means of the photoconductive ohmic switch characteristics, the authors have designed a positive feedback control network which has a very fast response time, and can couple a voltage of up to a thousand volts. Using this unit in a Nd:YAG laser, they have successfully realized a very stable mode-locked pulse train with pulse width shorter than 100 ps. The operation principle, and the results of the preliminary experiments are presented here. 1 ref., 3 figs

  2. Hersendood. Mackies leibniziaanse herinterpretatie van Lockes theorie van persoonsidentiteit

    OpenAIRE

    De Vleeschouwer, Gregory

    2009-01-01

    In his book, 'Problems from Locke', John Leslie Mackie presents a theory of personal identity (pi) that is meant to be a supplement and correction of Locke's pi-theory. In a first part I introduce the criterion of pi that was standard before Locke's pi-theory. By showing in a second part how Locke reacted against this traditional criterion, I show wherein the singularity of Locke's pi-theory exists. In a third part I explain how Leibniz is moved by the same solicitude as Locke, but also how h...

  3. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  4. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  5. Discretely tunable micromachined injection-locked lasers

    International Nuclear Information System (INIS)

    Cai, H; Yu, M B; Lo, G Q; Kwong, D L; Zhang, X M; Liu, A Q; Liu, B

    2010-01-01

    This paper reports a micromachined injection-locked laser (ILL) to provide tunable discrete wavelengths. It utilizes a non-continuously tunable laser as the master to lock a Fabry–Pérot semiconductor laser chip. Both lasers are integrated into a deep-etched silicon chip with dimensions of 3 mm × 3 mm × 0.8 mm. Based on the experimental results, significant improvements in the optical power and spectral purity have been achieved in the fully locked state, and optical hysteresis and bistability have also been observed in response to the changes of the output wavelength and optical power of the master laser. As a whole system, the micromachined ILL is able to provide single mode, discrete wavelength tuning, high power and direct modulation with small size and single-chip solution, making it promising for advanced optical communications such as wavelength division multiplexing optical access networks.

  6. Weak-light phase locking for LISA

    International Nuclear Information System (INIS)

    McNamara, Paul W

    2005-01-01

    The long armlengths of the LISA interferometer, and the finite aperture of the telescope, lead to an optical power attenuation of ∼10 -10 of the transmitted to received light. Simple reflection at the end of the arm is therefore not an optimum interferometric design. Instead, a local laser is offset phase locked to the weak incoming beam, transferring the phase information of the incoming to the outgoing light. This paper reports on an experiment to characterize a weak-light phase-locking scheme suitable for LISA in which a diode-pumped, Nd:YAG, non-planar ring oscillator (NPRO) is offset phase locked to a low-power (13 pW) frequency stabilized master NPRO. Preliminary results of the relative phase noise of the slave laser shows shot noise limited performance above 0.4 Hz. Excess noise is observed at lower frequencies, most probably due to thermal effects in the optical arrangement and phase-sensing electronics

  7. Using river locks to teach hydrodynamic concepts

    Science.gov (United States)

    Carvalho-Santos, Vagson L.; Mendes, Thales C.; Silva, Enisvaldo C.; Rios, Márcio L.; Silva, Anderson A. P.

    2013-11-01

    In this work, the use of a river lock as a non-formal setting for teaching hydrodynamical concepts is proposed. In particular, we describe the operation of a river lock situated at the Sobradinho dam, on the São Francisco River (Brazil). A model to represent and to analyse the dynamics of river lock operation is presented and we derive the dynamical equations for the rising of the water column as an example to understand the Euler equation. Furthermore, with this activity, we enable the integration of content initially introduced in the classroom with practical applications, thereby allowing the association of physical themes to content relevant in disciplines such as history and geography. In addition, experiences of this kind enable teachers to talk about the environmental and social impacts caused by the construction of a dam and, consequently, a crossover of concepts has been made possible, leading to more meaningful learning for the students.

  8. Using river locks to teach hydrodynamic concepts

    International Nuclear Information System (INIS)

    Carvalho-Santos, Vagson L; Mendes, Thales C; Silva, Enisvaldo C; Rios, Márcio L; Silva, Anderson A P

    2013-01-01

    In this work, the use of a river lock as a non-formal setting for teaching hydrodynamical concepts is proposed. In particular, we describe the operation of a river lock situated at the Sobradinho dam, on the São Francisco River (Brazil). A model to represent and to analyse the dynamics of river lock operation is presented and we derive the dynamical equations for the rising of the water column as an example to understand the Euler equation. Furthermore, with this activity, we enable the integration of content initially introduced in the classroom with practical applications, thereby allowing the association of physical themes to content relevant in disciplines such as history and geography. In addition, experiences of this kind enable teachers to talk about the environmental and social impacts caused by the construction of a dam and, consequently, a crossover of concepts has been made possible, leading to more meaningful learning for the students. (paper)

  9. John Locke and the right to resistance

    Directory of Open Access Journals (Sweden)

    Jovanov Ilija D.

    2015-01-01

    Full Text Available John Locke was a great thinker and many works have been devoted to clear up his theories. One of the most significant, stated in his principal work, Two Treatises of Government, is the theory of the right to resistance. It was a bit revolutionary then, and to a large extent it is today. Domination of legal positivism is negation of that, by Locke, natural right. However, the fact is that in recent times the resistance to the established power occurs in a number of countries and in different forms, so that the idea of the right to resistance becomes live question again. In this regard it is interesting to consider Locke's viewpoint on this important issue and to determine whether his theory on the resistance is applicable in modern societies.

  10. SWITCHED REFERENCE PHASE LOCK LOOP (SRPLL)

    International Nuclear Information System (INIS)

    KERNER, T.

    2001-01-01

    The Brookhaven National Laboratory Relativistic Heavy Ion Collider (RHIC) has two beam synchronous event links (BSL), one for each ring, which use the 28 MHz ring low level rf to distribute event codes synchronously with a precise phase relationship to the beam. During a cogging reset just before injection, the low level rf sine wave is interrupted which causes the BSL receivers to lose lock. Lock loss in turn causes false triggers and other undesirable-effects on the beam position monitors (BPM), ionization profile monitors (IPM), the tune meter and various experiments which use the BSLs. To rectify these problems, a SRPLL has been inserted between the beam synchronous master and the low level rf source. The SRPLL inserts a frequency and phase continuous splice over the dead-band gap in the rf source created during a cogging reset. The splice removes the gap and prevents the distributed BSL receivers from losing lock

  11. High-Order Frequency-Locked Loops

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In very recent years, some attempts for designing high-order frequency-locked loops (FLLs) have been made. Nevertheless, the advantages and disadvantages of these structures, particularly in comparison with a standard FLL and high-order phase-locked loops (PLLs), are rather unclear. This lack...... study, and its small-signal modeling, stability analysis, and parameter tuning are presented. Finally, to gain insight about advantages and disadvantages of high-order FLLs, a theoretical and experimental performance comparison between the designed second-order FLL and a standard FLL (first-order FLL...

  12. Mode-locked silicon evanescent lasers.

    Science.gov (United States)

    Koch, Brian R; Fang, Alexander W; Cohen, Oded; Bowers, John E

    2007-09-03

    We demonstrate electrically pumped lasers on silicon that produce pulses at repetition rates up to 40 GHz. The mode locked lasers generate 4 ps pulses with low jitter and extinction ratios above 18 dB, making them suitable for data and telecommunication transmitters and for clock generation and distribution. Results of both passive and hybrid mode locking are discussed. This type of device could enable new silicon based integrated technologies, such as optical time division multiplexing (OTDM), wavelength division multiplexing (WDM), and optical code division multiple access (OCDMA).

  13. Drag and Torque on Locked Screw Propeller

    Directory of Open Access Journals (Sweden)

    Tomasz Tabaczek

    2014-09-01

    Full Text Available Few data on drag and torque on locked propeller towed in water are available in literature. Those data refer to propellers of specific geometry (number of blades, blade area, pitch and skew of blades. The estimation of drag and torque of an arbitrary propeller considered in analysis of ship resistance or propulsion is laborious. The authors collected and reviewed test data available in the literature. Based on collected data there were developed the empirical formulae for estimation of hydrodynamic drag and torque acting on locked screw propeller. Supplementary CFD computations were carried out in order to prove the applicability of the formulae to modern moderately skewed screw propellers.

  14. John Locke on persons and personal identity

    OpenAIRE

    Boeker, Ruth

    2013-01-01

    John Locke claims both that ‘person’ is a forensic term and that personal identity consists in sameness of consciousness. The aim of my dissertation is to explain and critically assess how Locke links his moral and legal account of personhood to his account of personal identity in terms of sameness of consciousness. My interpretation of Locke’s account of persons and personal identity is embedded in Locke’s sortal-dependent account of identity. Locke’s sortal-dependent ac...

  15. Optimal database locks for efficient integrity checking

    DEFF Research Database (Denmark)

    Martinenghi, Davide

    2004-01-01

    In concurrent database systems, correctness of update transactions refers to the equivalent effects of the execution schedule and some serial schedule over the same set of transactions. Integrity constraints add further semantic requirements to the correctness of the database states reached upon...... the execution of update transactions. Several methods for efficient integrity checking and enforcing exist. We show in this paper how to apply one such method to automatically extend update transactions with locks and simplified consistency tests on the locked entities. All schedules produced in this way...

  16. Navigation Study, Colorado Locks, Colorado River, Matagorda, Texas

    National Research Council Canada - National Science Library

    McCollum, Randy

    2000-01-01

    A 1:70 physical navigation model was built to replicate the Matagorda Locks, approximately one mile of the GIWW east of the locks, approximately one-half mile of the Colorado River north of the GIWW...

  17. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  18. Locks at reactor safety containments of nuclear power plants

    International Nuclear Information System (INIS)

    1978-12-01

    The rule is to be applied for material access locks. A material access lock as defined by this rule is a pressure resistant and technically gas-tight hollow body that is connected with the containment and has got two doors, the inner door of which connects the lock chamber with the interior of the containment and the outer door connects the lock chamber with the outside. It serves exclusively for transferring material or objects. (orig./HP) [de

  19. Performance Monitoring System: Summary of Lock Statistics. Revision 1.

    Science.gov (United States)

    1985-12-01

    2751 84 4057 4141 526 798 18 1342 5727 19 5523 3996 4587 8583 1056 1630 35 2721 6536LOCK A DAMI 2 AUXILIARY I Ins NO DATA RECORDD FOR THIS LOCK- " LOCK I...TOTAL (KTOMS) ’ - (AVt OPNP ETC) ’’ ,q [ " ARKANSAS RIVER "" FORRELL LOCK IP 7A/3TRC 9/N83 UPBOUID STATISTICS ISO 53 42 M6 553 356 909 221 41 21 M8

  20. Multiprocessor Real-Time Locking Protocols for Replicated Resources

    Science.gov (United States)

    2016-07-01

    assignment problem, the ac- tual identities of the allocated replicas must be known. When locking protocols are used, tasks may experience delays due to both...Multiprocessor Real-Time Locking Protocols for Replicated Resources ∗ Catherine E. Jarrett1, Kecheng Yang1, Ming Yang1, Pontus Ekberg2, and James H...replicas to execute. In prior work on replicated resources, k-exclusion locks have been used, but this restricts tasks to lock only one replica at a time. To

  1. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  2. Lock-free parallel garbage collection

    NARCIS (Netherlands)

    H. Gao; J.F. Groote (Jan Friso); W.H. Hesselink (Wim)

    2005-01-01

    htmlabstract This paper presents a lock-free parallel algorithm for mark&sweep garbage collection (GC) in a realistic model using synchronization primitives compare-and-swap (CAS) and load-linked/store-conditional (LL/SC) offered by machine architectures. Mutators and collectors can simultaneously

  3. A Mode Locked UV-FEL

    CERN Document Server

    Parvin, Parviz

    2004-01-01

    An appropriate resonator has been designed to generate femtosecond mode locked pulses in a UV FEL with the modulator performance based on the gain switching. The gain broadening due to electron energy spread affects on the gain parameters, small signal gain (γ0) and saturation intensity (Is), to determine the optimum output coupling as small.

  4. CMOS switched current phase-locked loop

    NARCIS (Netherlands)

    Leenaerts, D.M.W.; Persoon, G.G.; Putter, B.M.

    1997-01-01

    The authors present an integrated circuit realisation of a switched current phase-locked loop (PLL) in standard 2.4 µm CMOS technology. The centre frequency is tunable to 1 MHz at a clock frequency of 5.46 MHz. The PLL has a measured maximum phase error of 21 degrees. The chip consumes

  5. Phase locking of optically coupled lasers

    International Nuclear Information System (INIS)

    Glova, A F

    2003-01-01

    A review of studies of the properties of radiation from optically coupled lasers is presented. The methods for phase locking the fields in optically coupled lasers of different types are considered and the methods for supermode selection and correction of the radiation pattern are discussed. (review)

  6. A locked nucleic Acid-based nanocrawler

    DEFF Research Database (Denmark)

    Astakhova, I Kira; Pasternak, Karol; Campbell, Meghan A

    2013-01-01

    Herein we introduce a novel fluorescent LNA/DNA machine, a nanocrawler, which reversibly moves along a directionally polar complementary road controlled by affinity-enhancing locked nucleic acid (LNA) monomers and additional regulatory strands. Polyaromatic hydrocarbon (PAH) dyes attached to 2...

  7. 49 CFR 236.742 - Dog, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Dog, locking. 236.742 Section 236.742 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.742 Dog...

  8. A New Perspective on Job Lock

    Science.gov (United States)

    Huysse-Gaytandjieva, Anna; Groot, Wim; Pavlova, Milena

    2013-01-01

    This paper analyses the situation when employees fail to adapt to overall job dissatisfaction. By combining the existing knowledge in economics on job lock and in psychology on employees' feeling of being "stuck" at work, the paper explains why some employees fail to adapt when dissatisfied with their job. Thus, the paper aims to expand…

  9. Locks & keys service moves to building 55

    CERN Multimedia

    2012-01-01

    Please note that as of July 12 Locks & keys service will be at building 55 second floor. The opening hours are as follows: 08:30 am to 12:30 pm - 1:30 pm to 5:30 pm. The procedures and rules relating to applications for key and cylinder have not changed. GI-IS Group

  10. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  11. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  12. Navigation Study of Lower Lock Approach, John Day Lock and Dam, Columbia River, Oregon

    National Research Council Canada - National Science Library

    Wilson, Donald

    2001-01-01

    Representatives of the Columbia River Towing Association reported recent structural and/or operational changes at John Day Lock and Dam have created difficult navigation conditions for tows entering...

  13. 30 CFR 56.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  14. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  15. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  16. Locked modes and magnetic field errors in MST

    International Nuclear Information System (INIS)

    Almagri, A.F.; Assadi, S.; Prager, S.C.; Sarff, J.S.; Kerst, D.W.

    1992-06-01

    In the MST reversed field pinch magnetic oscillations become stationary (locked) in the lab frame as a result of a process involving interactions between the modes, sawteeth, and field errors. Several helical modes become phase locked to each other to form a rotating localized disturbance, the disturbance locks to an impulsive field error generated at a sawtooth crash, the error fields grow monotonically after locking (perhaps due to an unstable interaction between the modes and field error), and over the tens of milliseconds of growth confinement degrades and the discharge eventually terminates. Field error control has been partially successful in eliminating locking

  17. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  19. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  20. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  1. Wall locking and multiple nonlinear states of magnetic islands

    International Nuclear Information System (INIS)

    Persson, Mikael; Australian National Univ., Canberra, ACT

    1994-01-01

    The nonlinear evolution of magnetic islands is analysed in configurations with multiple resonant magnetic surfaces. The existence of multiple nonlinear steady states, is discussed. These are shown to be associated with states where the dynamics around the different rational surfaces are coupled or decoupled and in the presence of a wall of finite resistivity may correspond wall-locked or non-wall-locked magnetic islands. For the case of strong wall stabilization the locking is shown to consist of two different phases. During the first phase the locking of the plasma at the different rational surfaces occurs. Only when the outermost resonant magnetic surface has locked to the inner surfaces can the actual wall locking process take place. Consequently, wall locking, of a global mode, involving more than one rational surface, can be prevented by the decoupling of the resonant magnetic surfaces by plasma rotation. Possible implications on tokamak experiments are discussed. (author)

  2. Power spectrum of an injection-locked Josephson oscillator

    International Nuclear Information System (INIS)

    Stancampiano, C.V.; Shapiro, S.

    1975-01-01

    Experiments have shown that a Josephson oscillator, exposed to a weak narrow-band input signal, exhibits behavior characteristic of an injection-locked oscillator. When in lock, Adler's theory of injection locking describes the experimental observations reasonably well. The range of applicability of the theory is extended to the out-of-lock regime where a spectrum of output frequencies is observed. Obtaining the theoretical output power spectrum requires solving a differential equation having the same form as the equation describing the resistively shunted junction model of Stewart and of McCumber. Experimental measurements of the output spectrum of a nearly locked Josephson oscillator are shown to be in reasonable agreement with the theory. Additional results discussed briefly include the observation of a frequency dependence of the locked Josephson oscillator output and experiments in which a Josephson oscillator-mixer was injection locked by a weak signal at the rf

  3. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  4. Three Alternative Symbol-Lock Detectors

    Science.gov (United States)

    Shihabi, Mazen M.; Hinedi, Sami M.; Shah, Biren N.

    1993-01-01

    Three symbol-lock detectors proposed as alternatives in advanced receivers processing non-return-to-zero binary data signals. Two perform operations similar to those of older square-law and absolute-value types. However, integrals computed during nonoverlapping symbol periods and, therefore, only one integrator needed in each such detector. Proposed detectors simpler, but performances worse because noises in overlapping samples correlated, whereas noises in nonoverlapping samples not correlated. Third detector is signal-power-estimator type. Signal integrated during successive half symbol cycles, and therefore only one integrator needed. Half-cycle integrals multiplied to eliminate effect of symbol polarity, and products accumulated during M-cycle observation period to smooth out estimate of signal power. If estimated signal power exceeds threshold, delta, then lock declared.

  5. Traumatic knee extension deficit (the locked knee)

    DEFF Research Database (Denmark)

    Helmark, I C; Neergaard, K; Krogsgaard, M R

    2007-01-01

    In the present study we investigated the validity of magnetic resonance imaging (MRI) and arthroscopy in knees with acute, traumatic extension deficit (the "locked knee"), and evaluated whether arthroscopy of knees with no mechanical pathology could be avoided by MRI evaluation. The study consisted...... of 50 patients who had an acute, traumatic extension deficit of the knee. All patients were submitted to MRI prior to arthroscopy. Following MRI and surgery, standardized forms were filled out, attempting to objectify the findings. The orthopaedic surgeon was not aware of the MRI result prior to surgery....... Evaluating MRI, all grade-3 meniscal lesions were considered able to cause a mechanical block as well as acute partial or total anterior cruciate ligament (ACL)-ruptures. ACL-ruptures with an old appearance were not considered able to cause locking. Assuming that arthroscopy was the gold standard...

  6. Mode-locking via dissipative Faraday instability.

    Science.gov (United States)

    Tarasov, Nikita; Perego, Auro M; Churkin, Dmitry V; Staliunas, Kestutis; Turitsyn, Sergei K

    2016-08-09

    Emergence of coherent structures and patterns at the nonlinear stage of modulation instability of a uniform state is an inherent feature of many biological, physical and engineering systems. There are several well-studied classical modulation instabilities, such as Benjamin-Feir, Turing and Faraday instability, which play a critical role in the self-organization of energy and matter in non-equilibrium physical, chemical and biological systems. Here we experimentally demonstrate the dissipative Faraday instability induced by spatially periodic zig-zag modulation of a dissipative parameter of the system-spectrally dependent losses-achieving generation of temporal patterns and high-harmonic mode-locking in a fibre laser. We demonstrate features of this instability that distinguish it from both the Benjamin-Feir and the purely dispersive Faraday instability. Our results open the possibilities for new designs of mode-locked lasers and can be extended to other fields of physics and engineering.

  7. Quantum locking of mirrors in interferometers.

    Science.gov (United States)

    Courty, Jean-Michel; Heidmann, Antoine; Pinard, Michel

    2003-02-28

    We show that quantum noise in very sensitive interferometric measurements such as gravitational-wave detectors can be drastically modified by quantum feedback. We present a new scheme based on active control to lock the motion of a mirror to a reference mirror at the quantum level. This simple technique allows one to reduce quantum effects of radiation pressure and to greatly enhance the sensitivity of the detection.

  8. Dither Cavity Length Controller with Iodine Locking

    Directory of Open Access Journals (Sweden)

    Lawson Marty

    2016-01-01

    Full Text Available A cavity length controller for a seeded Q-switched frequency doubled Nd:YAG laser is constructed. The cavity length controller uses a piezo-mirror dither voltage to find the optimum length for the seeded cavity. The piezo-mirror dither also dithers the optical frequency of the output pulse. [1]. This dither in optical frequency is then used to lock to an Iodine absorption line.

  9. Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

    Science.gov (United States)

    Sisko, Zachary W; Teeter, Matthew G; Lanting, Brent A; Howard, James L; McCalden, Richard W; Naudie, Douglas D; MacDonald, Steven J; Vasarhelyi, Edward M

    2017-12-01

    Tibial baseplate roughness and polyethylene-insert micromotion resulting from locking-mechanism loosening can lead to polyethylene backside wear in TKAs. However, many retrieval studies examining these variables have evaluated only older TKA implant designs. We used implant-retrieval analysis to examine if there were differences in: (1) backside damage scores, (2) backside damage modes, and (3) backside linear wear rates in five TKA implant designs owing to differing baseplate surface roughness and locking mechanisms. Additionally, we examined if (4) patient demographics influence backside damage and wear. Five TKA implant models (four modern and one historical design) were selected with different tibial baseplate and/or locking mechanism designs. Six tibial inserts retrieved at the time of revision from each TKA model were matched for time in vivo, age of the patient at TKA revision, BMI, sex, revision number, and revision reason. Each insert backside was analyzed for: (1) visual total damage score and (2) individual visual damage modes, both by two observers and with an intraclass correlation coefficient of 0.66 (95% CI, 0.39-0.92), and (3) linear wear rate measured by micro-CT. Median primary outcomes were compared among the five designs. For our given sample size among five groups we could detect with 80% power a 10-point difference in damage score and an 0.11-mm per year difference in wear rate. The polished tibial design with a partial peripheral capture locking mechanism and anterior constraint showed a lower total damage score compared with the nonpolished tibial design with only a complete peripheral-rim locking mechanism (median, 12.5; range, 9.5-18.0; 95% CI, 9.58-16.42 versus median, 22.3; range, 15.5-27.0; 95% CI, 17.5-26.5; p = 0.019). The polished baseplate with a tongue-in-groove locking mechanism showed more abrasions than the nonpolished baseplate with a peripheral-rim capture and antirotational island (median, 7.25; range, 0.5-8.0; 95% CI, 2

  10. Programmable Self-Locking Origami Mechanical Metamaterials.

    Science.gov (United States)

    Fang, Hongbin; Chu, Shih-Cheng A; Xia, Yutong; Wang, Kon-Well

    2018-04-01

    Developing mechanical metamaterials with programmable properties is an emerging topic receiving wide attention. While the programmability mainly originates from structural multistability in previously designed metamaterials, here it is shown that nonflat-foldable origami provides a new platform to achieve programmability via its intrinsic self-locking and reconfiguration capabilities. Working with the single-collinear degree-4 vertex origami tessellation, it is found that each unit cell can self-lock at a nonflat configuration and, therefore, possesses wide design space to program its foldability and relative density. Experiments and numerical analyses are combined to demonstrate that by switching the deformation modes of the constituent cell from prelocking folding to postlocking pressing, its stiffness experiences a sudden jump, implying a limiting-stopper effect. Such a stiffness jump is generalized to a multisegment piecewise stiffness profile in a multilayer model. Furthermore, it is revealed that via strategically switching the constituent cells' deformation modes through passive or active means, the n-layer metamaterial's stiffness is controllable among 2 n target stiffness values. Additionally, the piecewise stiffness can also trigger bistable responses dynamically under harmonic excitations, highlighting the metamaterial's rich dynamic performance. These unique characteristics of self-locking origami present new paths for creating programmable mechanical metamaterials with in situ controllable mechanical properties. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. [Tibiotalocalcaneal arthrodesis using a humeral locking plate].

    Science.gov (United States)

    Cabrera Méndez, M P; Gamba, C; Hernández, E; Molano, J; Andrade, J C

    2016-01-01

    To describe the results of tibiotalocalcáneal arthrodesis (TTC) using a humeral locking plate. A retrospective, observational study was conducted between January 2007 and December 2013 in the Hospital Militar Central de Bogotá. The study included patients with symptomatic osteoarthritis diagnosed clinically and radiologically, and who underwent TTC arthrodesis using a humeral locking plate with a minimum follow up of 6 months. The total number patients was 35, of whom 7 (20%) were women and 28 (80%) men, with a mean age 36.3 years (19.77). 74% with post-traumatic arthritis, most of them secondary to gunshot wounds and fragmentation weapons, and neuropathic in 20%. An autogenous graft was used in 13 cases, and 14 cases using both, with a mean consolidation time of 4.37 months. Complications include, delayed union in 3 cases, and surgical site infection in 4. The postoperative functionality (AOFAS) mean was 66.7/100 points, with a score of 2.35 on a visual analogue pain scale. TTC arthrodesis using a humeral locking plate is a suitable option for fixing this type of arthrodesis, with a low rate of complications, and postoperative results that revealed satisfactory improvement in pain and consolidation. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  12. Self-locking degree-4 vertex origami structures.

    Science.gov (United States)

    Fang, Hongbin; Li, Suyi; Wang, K W

    2016-11-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications.

  13. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  14. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers.

    Science.gov (United States)

    Jin, Tian; Yuan, Heliang; Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-12-04

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio ( C / N ₀) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C / N ₀ can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis.

  15. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  16. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  17. Initial outcome and efficacy of S3 proximal humerus locking plate in the treatment of proximal humerus fractures

    International Nuclear Information System (INIS)

    Zhang Zhiming; Zhu Xuesong; Bao Zhaohua; Yang Huilin

    2012-01-01

    Objective: to explore the initial outcome and efficacy of S 3 proximal humerus locking plate in the treatment of proximal humerus fractures. Methods: Twenty-two patients with proximal humerus fracture were treated with the S 3 proximal humerus locking plate. Most of the fractures were complex, two-part (n=4), three-part (n=11) and four-part (n=7) fractures according to the Neer classification of the proximal humerus fractures. Results: All patients were followed up for 3∼15 months. There were no complications related to the implant including loosening or breakage of the plate. Good and excellent results were documented in 17 patients fair results in 4 patients according the Neer scores of shoulder. Conclusion: New design concepts of S 3 proximal humerus plate provide the subchondral support and the internal fixation support. With the addition of the proper exercise of the shoulder joint, the outcomes would be satisfied. (authors)

  18. Delay differential equations for mode-locked semiconductor lasers.

    Science.gov (United States)

    Vladimirov, Andrei G; Turaev, Dmitry; Kozyreff, Gregory

    2004-06-01

    We propose a new model for passive mode locking that is a set of ordinary delay differential equations. We assume a ring-cavity geometry and Lorentzian spectral filtering of the pulses but do not use small gain and loss and weak saturation approximations. By means of a continuation method, we study mode-locking solutions and their stability. We find that stable mode locking can exist even when the nonlasing state between pulses becomes unstable.

  19. Analysis of peer-to-peer locking of magnetrons

    International Nuclear Information System (INIS)

    Pengvanich, P.; Lau, Y. Y.; Cruz, E.; Gilgenbach, R. M.; Hoff, B.; Luginsland, J. W.

    2008-01-01

    The condition for mutual, or peer-to-peer, locking of two magnetrons is derived. This condition reduces to Adler's classical phase-locking condition in the limit where one magnetron becomes the ''master'' and the other becomes the ''slave.'' The formulation is extended to the peer-to-peer locking of N magnetrons, under the assumption that the electromagnetic coupling among the N magnetrons is modeled by an N-port network.

  20. Locking of metacarpophalangeal joints in a patient with acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Y.; Tanaka, N.; Isoya, Eiji [Dept. of Orthopaedic Surgery, Soseikai General Hospital, Kyoto (Japan)

    1999-11-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  1. Locking of metacarpophalangeal joints in a patient with acromegaly

    International Nuclear Information System (INIS)

    Tani, Y.; Tanaka, N.; Isoya, Eiji

    1999-01-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  2. An Evaluation of Coarse-Grained Locking for Multicore Microkernels

    OpenAIRE

    Elphinstone, Kevin; Zarrabi, Amirreza; Danis, Adrian; Shen, Yanyan; Heiser, Gernot

    2016-01-01

    The trade-off between coarse- and fine-grained locking is a well understood issue in operating systems. Coarse-grained locking provides lower overhead under low contention, fine-grained locking provides higher scalability under contention, though at the expense of implementation complexity and re- duced best-case performance. We revisit this trade-off in the context of microkernels and tightly-coupled cores with shared caches and low inter-core migration latencies. We evaluate performance on ...

  3. Progress as Compositional Lock-Freedom

    DEFF Research Database (Denmark)

    Carbone, Marco; Dardha, Ornela; Montesi, Fabrizio

    2014-01-01

    A session-based process satisfies the progress property if its sessions never get stuck when it is executed in an adequate context. Previous work studied how to define progress by introducing the notion of catalysers, execution contexts generated from the type of a process. In this paper, we refine...... such definition to capture a more intuitive notion of context adequacy for checking progress. Interestingly, our new catalysers lead to a novel characterisation of progress in terms of the standard notion of lock-freedom. Guided by this discovery, we also develop a conservative extension of catalysers that does...

  4. Locking classical correlations in quantum States.

    Science.gov (United States)

    DiVincenzo, David P; Horodecki, Michał; Leung, Debbie W; Smolin, John A; Terhal, Barbara M

    2004-02-13

    We show that there exist bipartite quantum states which contain a large locked classical correlation that is unlocked by a disproportionately small amount of classical communication. In particular, there are (2n+1)-qubit states for which a one-bit message doubles the optimal classical mutual information between measurement results on the subsystems, from n/2 bits to n bits. This phenomenon is impossible classically. However, states exhibiting this behavior need not be entangled. We study the range of states exhibiting this phenomenon and bound its magnitude.

  5. Advanced frequency synthesis by phase lock

    CERN Document Server

    Egan, William F

    2011-01-01

    "An addendum to the popular Frequency Synthesis by Phase Lock, 2nd ed, this book describes sigma-delta, a frequency synthesis technique that has gained prominence in recent years. In addition, Simulink will be employed extensively to guide the reader. Fractional-n, the still-used forerunner to sigma-delta, is also discussed. Sequences of simulated results allow the reader to gain a deeper understanding while detailed appendices provide information from various stages of development. Simulation models discussed in the chapters that are available online."--Provided by publisher.

  6. Saint Lawrence Seaway Additional Locks Study. Appendices.

    Science.gov (United States)

    1982-07-01

    1790320 1945 2370 27000 LO 710 i...l.I27.121.710.0443 23.00.769 12.229.146 2,3231.503 2.5~06.000 2.239.100 23.760.400 23.019.2002 3.413200 P.. Capita...1955. - ,. XISING EISENHOWER LOCK G ISO Se-s SP*c.--2 2, 13 TIL ANDBDROC ~~~~~~ AREA LIISO9TL AD All b 22 CORPS OF ENGINEERS BUFFAL0 NY RUFFALO DISTR

  7. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  8. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    Energy Technology Data Exchange (ETDEWEB)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan, E-mail: lining@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-05-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 mum RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm{sup 2}. The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  9. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    International Nuclear Information System (INIS)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan

    2009-01-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 μm RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm 2 . The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  10. Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating.

    Science.gov (United States)

    Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William

    2017-11-01

    Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  12. Reconfigurable Braille display with phase change locking

    Science.gov (United States)

    Soule, Cody W.; Lazarus, Nathan

    2016-07-01

    Automatically updated signs and displays for sighted people are common in today’s world. However, there is no cheap, low power equivalent available for the blind. This work demonstrates a reconfigurable Braille cell using the solid-to-liquid phase change of a low melting point alloy as a zero holding power locking mechanism. The device is actuated with the alloy in the liquid state, and is then allowed to solidify to lock the Braille dot in the actuated position. A low-cost manufacturing process is developed that includes molding of a rigid silicone to create pneumatic channels, and bonding of a thin membrane of a softer silicone on the surface for actuation. A plug of Field’s metal (melting point 62 °C) is placed in the pneumatic channels below each Braille dot to create the final device. The device is well suited for low duty cycle operation in applications such as signs, and is able to maintain its state indefinitely without additional power input. The display requires a pneumatic pressure of only 24 kPa for actuation, and reconfiguration has been demonstrated in less than a minute and a half.

  13. Tom Bevill Upper Lock Approach, Tennessee-Tombigbee Waterway, Alabama: Hydraulic Navigation Investigation

    National Research Council Canada - National Science Library

    Winkler, Michael

    2003-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  14. Scaling laws for mode lockings in circle maps

    International Nuclear Information System (INIS)

    Cvitanovic, P.; Shraiman, B.; Soederberg, B.

    1985-06-01

    The self-similar structure of mode lockings for circle maps is studied by means of the associated Farey trees. We investigate numerically several classes of scaling relations implicit in the Farey organization of mode lockings and discuss the extent to which they lead to universal scaling laws. (orig.)

  15. 30 CFR 57.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  16. Investigation on Locking and Pulling Modes in Analog Frequency Dividers

    Directory of Open Access Journals (Sweden)

    Antonio Buonomo

    2013-01-01

    Full Text Available We compare the main analytical results available to estimate the locking range, which is the key figure-of-merit of LC frequency dividers based on the injection locking phenomenon. Starting from the classical result by Adler concerning injection-locked oscillators, we elucidate the merits and the shortcomings of the different approaches to study injection-locked frequency dividers, with particular emphasis on divider-by-2. In particular, we show the potential of a perturbation approach which enables a more complete analysis of frequency dividers, making it possible to calculate not only the amplitude and the phase of the locked oscillation, but also the region where it exists and is stable, which defines the locking region. Finally, we analyze the dynamical behaviour of the dividers in the vicinity of the boundary of the locking region, showing that there exists a border region where the occurrence of the locking or the pulling operation mode is possible, depending on the initial conditions of the system.

  17. Lock-In Agreements in Venture Capital Backed UK IPOs

    NARCIS (Netherlands)

    Espenlaub, S.; Goergen, M.; Khurshed, A.; Renneboog, L.D.R.

    2002-01-01

    This paper examines the impact of venture-capital backing of UK companies issuing shares at flotation on the characteristics of the lock-in agreements entered into by the existing shareholders, and on the abnormal returns realised around the expiry of the directors' lock-in agreements.The study

  18. Aktuaalsetest tendentsidest elektroakustilise muusika alal Eestis / Gerhard Lock

    Index Scriptorium Estoniae

    Lock, Gerhard, 1978-

    2007-01-01

    Elektroakustilise muusika lähiajaloost, elektroakustilist muusikat viljelevatest Eesti heliloojatest. Age Hirv, Raun Juurikas, Liis Jürgens, Andrus Kallastu, Tatjana Kozlova, Ülo Krigul, Margo Kõlar, Märt-Matis Lill, Gerhard Lock, Hans-Gunter Lock, Malle Maltis, Jüri Reinvere, Mart Siimer, Mirjam Tally, Toomas Trass, Lauri-Dag Tüür oma muusikast

  19. Phase-locking regimes of photonic crystal nanocavity laser arrays

    DEFF Research Database (Denmark)

    Skovgård, Troels Suhr; Kristensen, Philip Trøst; Mørk, Jesper

    2011-01-01

    -difference time-domain calculations, the typical coupling strength is extracted for realistic structures. Phase-locking regimes are identified, and their stability with respect to parameter variation is investigated. The results suggest that quantum well devices are not well suited for phase-locked nanocavity...

  20. ELB-trees - Efficient Lock-free B+trees

    DEFF Research Database (Denmark)

    Bonnichsen, Lars Frydendal; Karlsson, Sven; Probst, Christian W.

    2014-01-01

    As computer systems scale in the number of processors, data structures with good parallel performance become increasingly important. Lock-free data structures promise improved parallel performance at the expense of higher complexity and sequential execution time.We present ELBtrees, a new lock-fr...

  1. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  2. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  3. Phase locking of vortex cores in two coupled magnetic nanopillars

    Directory of Open Access Journals (Sweden)

    Qiyuan Zhu

    2014-11-01

    Full Text Available Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. This work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.

  4. Spatially resolved detection of mutually locked Josephson junctions in arrays

    International Nuclear Information System (INIS)

    Keck, M.; Doderer, T.; Huebener, R.P.; Traeuble, T.; Dolata, R.; Weimann, T.; Niemeyer, J.

    1997-01-01

    Mutual locking due to the internal coupling in two-dimensional arrays of Josephson junctions was investigated. The appearance of Shapiro steps in the current versus voltage curve of a coupled on-chip detector junction is used to indicate coherent oscillations in the array. A highly coherent state is observed for some range of the array bias current. By scanning the array with a low-power electron beam, mutually locked junctions remain locked while the unlocked junctions generate a beam-induced additional voltage drop at the array. This imaging technique allows the detection of the nonlocked or weakly locked Josephson junctions in a (partially) locked array state. copyright 1997 American Institute of Physics

  5. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  6. Monolithic Hybrid and Passive Mode-Locked 40GHz Quantum Dot Laser Diodes

    DEFF Research Database (Denmark)

    Thompson, M. G.; Larsson, David; Rae, A. R.

    2006-01-01

    For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs.......For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs....

  7. Locking of intrinsic angular momentum in collision complexes

    International Nuclear Information System (INIS)

    Berengolts, Alexander.

    1995-04-01

    A concept of locking of the intrinsic angular momentum of a fragment of a collision complex to a body-fixed axis is widely used in the description of heavy-particle dynamics. The aim of this work is to provide a semiclassical description of the locking phenomenon which occur in diatomic and three atomic collision complexes. The first part of this work is devoted to the semiclassical study of the locking of the electronic angular momentum that occurs in slow collisions of two atoms, one in the spherically symmetric state and the other in state with j= 1. Here we calculate explicitly the complete locking matrix for different types of interatomic interactions. The elements of this matrix directly enter into the semiclassical expression for the different cross sections of polarized atoms. Limitations to the notion of the the locking radius and slipping probability are discussed in connection with the steepness of the interaction. Numerical calculations confirm analytical result: the optimal criterion for determination of the locking radius is a condition for the accumulated phase difference between two molecular states. Analytical expressions are suggested for the locking angle and the slipping probability. Implication of the locking approximation for calculation of the quasiclassical scattering matrix is discussed. The second part considers the locking of the rotational angular momentum of a diatom in the decomposition of a triatomic complexes. We discuss here cases J = 1,2,3 and 4, but restrict ourselves to calculation of the so-called dynamic orientation of the diatomic fragment. The letter represents one of the characteristics of the locking matrix which in principle can be measured experimentally. The orientation is created as a result of the interplay between the adiabatic interaction in the atom- diatom exit channel and the rotationally non adiabatic coupling in the perturbed rotor region

  8. Heterogeneous Silicon III-V Mode-Locked Lasers

    Science.gov (United States)

    Davenport, Michael Loehrlein

    Mode-locked lasers are useful for a variety of applications, such as sensing, telecommunication, and surgical instruments. This work focuses on integrated-circuit mode-locked lasers: those that combine multiple optical and electronic functions and are manufactured together on a single chip. While this allows production at high volume and lower cost, the true potential of integration is to open applications for mode-locked laser diodes where solid state lasers cannot fit, either due to size and power consumption constraints, or where small optical or electrical paths are needed for high bandwidth. Unfortunately, most high power and highly stable mode-locked laser diode demonstrations in scientific literature are based on the Fabry-Perot resonator design, with cleaved mirrors, and are unsuitable for use in integrated circuits because of the difficulty of producing integrated Fabry-Perot cavities. We use silicon photonics and heterogeneous integration with III-V gain material to produce the most powerful and lowest noise fully integrated mode-locked laser diode in the 20 GHz frequency range. If low noise and high peak power are required, it is arguably the best performing fully integrated mode-locked laser ever demonstrated. We present the design methodology and experimental pathway to realize a fully integrated mode-locked laser diode. The construction of the device, beginning with the selection of an integration platform, and proceeding through the fabrication process to final optimization, is presented in detail. The dependence of mode-locked laser performance on a wide variety of design parameters is presented. Applications for integrated circuit mode-locked lasers are also discussed, as well as proposed methods for using integration to improve mode-locking performance to beyond the current state of the art.

  9. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  10. DLS 5.0--the biomechanical effects of dynamic locking screws.

    Directory of Open Access Journals (Sweden)

    Stefan Döbele

    Full Text Available INTRODUCTION: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0. METHODS: Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0. A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured. RESULTS: The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N. CONCLUSIONS: The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.

  11. Shareholder Lock-In Contracts : Share Price and Trading Volume Effects at the Lock-In Expiry

    NARCIS (Netherlands)

    Angenandt, P.P.; Goergen, M.; Renneboog, L.D.R.

    2005-01-01

    This paper unveils the diversity in lock-in agreements of firms listed on the Nouveau Marche stock exchange in France.We give the main economic reasons why shareholders adopt lock-in agreements that are more stringent than legally required.We relate the abnormal returns and the abnormal volume at

  12. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  13. An elevator for locked drilling pipes

    Energy Technology Data Exchange (ETDEWEB)

    Gurbanov, R.S.; Abbasov, E.M.; Ismailov, A.A.; Mamedov, Yu.S.; Safarov, A.A.

    1983-01-01

    An elevator is proposed, which includes a body with a door. To reduce the probability of gas shows in a well with high speed lowering and lifting of the column of locked drilling pipes through providing the possibility of feeding a drilling mud in this case into the mine, the elevator is equipped with a pneumatic cylinder with a two way hollow rod, on one face of which a sealing element is mounted for sealing the drilling pipe and on the other, an adapter for feeding the drilling mud. The rod is linked with the sleeve of the pneumatic cylinder, which is rigidly linked with the body with the capability of axial movement without rotation.

  14. Gapless Color-Flavor-Locked Quark Matter

    DEFF Research Database (Denmark)

    Alford, Mark; Kouvaris, Christoforos; Rajagopal, Krishna

    2004-01-01

    In neutral cold quark matter that is sufficiently dense that the strange quark mass M_s is unimportant, all nine quarks (three colors; three flavors) pair in a color-flavor locked (CFL) pattern, and all fermionic quasiparticles have a gap. We argue that as a function of decreasing quark chemical...... potential mu or increasing M_s, there is a quantum phase transition from the CFL phase to a new ``gapless CFL phase'' in which only seven quasiparticles have a gap. The transition occurs where M_s^2/mu is approximately equal to 2*Delta, with Delta the gap parameter. Gapless CFL, like CFL, leaves unbroken...... a linear combination Qtilde of electric and color charges, but it is a Qtilde-conductor with a nonzero electron density. These electrons and the gapless quark quasiparticles make the low energy effective theory of the gapless CFL phase and, consequently, its astrophysical properties are qualitatively...

  15. Dynamics of Tidally Locked, Ultrafast Rotating Atmospheres

    Science.gov (United States)

    Tan, Xianyu; Showman, Adam P.

    2017-10-01

    Tidally locked gas giants, which exhibit a novel regime of day-night thermal forcing and extreme stellar irradiation, are typically in several-day orbits, implying slow rotation and a modest role for rotation in the atmospheric circulation. Nevertheless, there exist a class of gas-giant, highly irradiated objects - brown dwarfs orbiting white dwarfs in extremely tight orbits - whose orbital and hence rotation periods are as short as 1-2 hours. Spitzer phase curves and other observations have already been obtained for this fascinating class of objects, which raise fundamental questions about the role of rotation in controlling the circulation. So far, most modeling studies have investigated rotation periods exceeding a day, as appropriate for typical hot Jupiters. In this work we investigate the dynamics of tidally locked atmospheres in shorter rotation periods down to about two hours. With increasing rotation rate (decreasing rotation period), we show that the width of the equatorial eastward jet decreases, consistent with the narrowing of wave-mean-flow interacting region due to decrease of the equatorial deformation radius. The eastward-shifted equatorial hot spot offset decreases accordingly, and the westward-shifted hot regions poleward of the equatorial jet associated with Rossby gyres become increasingly distinctive. At high latitudes, winds becomes weaker and more geostrophic. The day-night temperature contrast becomes larger due to the stronger influence of rotation. Our simulated atmospheres exhibit small-scale variability, presumably caused by shear instability. Unlike typical hot Jupiters, phase curves of fast-rotating models show an alignment of peak flux to secondary eclipse. Our results have important implications for phase curve observations of brown dwarfs orbiting white dwarfs in ultra tight orbits.

  16. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  17. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study

    Directory of Open Access Journals (Sweden)

    Sermon An

    2008-12-01

    Full Text Available Abstract Background Proximal humerus fractures are one of the most common fractures. Intramedullary locked nailing is becoming a popular alternative treatment, especially for easier fracture patterns. Although axillary nerve injury has been reported, no study has compared the safety of the proximal locking options relative to the axillary nerve and the ascending branch of the anterior circumflex artery. Method Six different commercially available proximal humeral nails were implanted in 30 shoulders of 18 cadavers. After fluoroscopically guided implantation the shoulders were carefully dissected and the distance between the locking screws, the axillary nerve and the ascending branch of the anterior circumflex artery was measured. Results The course of the axillary nerve varies. A mean distance of 55.8 mm (SD = 5.3 between the lateral edge of the acromions and the axillary nerve at the middle of the humerus in a neutrally rotated position was observed. The minimum distance was 43.4 mm, the maximum 63.9 mm. Bent nails with oblique head interlocking bolts appeared to be the most dangerous in relation to the axillary nerve. The two designs featuring such a bend and oblique bolt showed a mean distance of the locking screw to the axillary nerve of 1 mm and 2.7 mm respectively Sirus (Zimmer® and (Stryker® T2 PHN (Proximal Humeral Nail. Regarding the ascending branch of the anterior circumflex artery, there was no difference between the nails which have an anteroposterior locking option. Conclusion It is of great importance for surgeons treating proximal humerus fractures to understand the relative risk of any procedure they perform. Since the designs of different nailing systems risk damaging the axillary nerve and ascending branch, blunt dissection, the use of protection sleeves during drilling and screw insertion, and individual risk evaluation prior to the use of a proximal humeral nail are advocated.

  18. Injection locking of optomechanical oscillators via acoustic waves

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-01

    Injection locking is a powerful technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators using similar or other types of oscillators. Here, we present the first demonstration of injection locking of a radiation-pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can easily be implemented on various platforms. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  19. Key-lock colloids in a nematic liquid crystal.

    Science.gov (United States)

    Silvestre, Nuno M; Tasinkevych, M

    2017-01-01

    The Landau-de Gennes free energy is used to study theoretically the effective interaction of spherical "key" and anisotropic "lock" colloidal particles. We assume identical anchoring properties of the surfaces of the key and of the lock particles, and we consider planar degenerate and perpendicular anchoring conditions separately. The lock particle is modeled as a spherical particle with a spherical dimple. When such a particle is introduced into a nematic liquid crystal, it orients its dimple at an oblique angle θ_{eq} with respect to the far field director n_{∞}. This angle depends on the depth of the dimple. Minimization results show that the free energy of a pair of key and lock particles exhibits a global minimum for the configuration when the key particle is facing the dimple of the lock colloidal particle. The preferred orientation ϕ_{eq} of the key-lock composite doublet relative to n_{∞} is robust against thermal fluctuations. The preferred orientation θ_{eq}^{(2)} of the dimple particle in the doublet is different from the isolated situation. This is related to the "direct" interaction of defects accompanying the key particle with the edge of the dimple. We propose that this nematic-amplified key-lock interaction can play an important role in self-organization and clustering of mixtures of colloidal particles with dimple colloids present.

  20. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  1. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  2. Brain communication in the locked-in state.

    Science.gov (United States)

    De Massari, Daniele; Ruf, Carolin A; Furdea, Adrian; Matuz, Tamara; van der Heiden, Linda; Halder, Sebastian; Silvoni, Stefano; Birbaumer, Niels

    2013-06-01

    Patients in the completely locked-in state have no means of communication and they represent the target population for brain-computer interface research in the last 15 years. Although different paradigms have been tested and different physiological signals used, to date no sufficiently documented completely locked-in state patient was able to control a brain-computer interface over an extended time period. We introduce Pavlovian semantic conditioning to enable basic communication in completely locked-in state. This novel paradigm is based on semantic conditioning for online classification of neuroelectric or any other physiological signals to discriminate between covert (cognitive) 'yes' and 'no' responses. The paradigm comprised the presentation of affirmative and negative statements used as conditioned stimuli, while the unconditioned stimulus consisted of electrical stimulation of the skin paired with affirmative statements. Three patients with advanced amyotrophic lateral sclerosis participated over an extended time period, one of which was in a completely locked-in state, the other two in the locked-in state. The patients' level of vigilance was assessed through auditory oddball procedures to study the correlation between vigilance level and the classifier's performance. The average online classification accuracies of slow cortical components of electroencephalographic signals were around chance level for all the patients. The use of a non-linear classifier in the offline classification procedure resulted in a substantial improvement of the accuracy in one locked-in state patient achieving 70% correct classification. A reliable level of performance in the completely locked-in state patient was not achieved uniformly throughout the 37 sessions despite intact cognitive processing capacity, but in some sessions communication accuracies up to 70% were achieved. Paradigm modifications are proposed. Rapid drop of vigilance was detected suggesting attentional

  3. Injection locking of optomechanical oscillators via acoustic waves.

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-02

    Injection locking is an effective technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators. As such, exploring new mechanisms for injection locking of emerging oscillators is important for their usage in various systems. Here, we present the first demonstration of injection locking of a radiation pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can be easily implemented on various platforms to lock different types of OMOs independent of their size and structure. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance, matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity, and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology, and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  4. A scalable lock-free hash table with open addressing

    DEFF Research Database (Denmark)

    Nielsen, Jesper Puge; Karlsson, Sven

    2016-01-01

    and concurrent operations without any locks. In this paper, we present a new fully lock-free open addressed hash table with a simpler design than prior published work. We split hash table insertions into two atomic phases: first inserting a value ignoring other concurrent operations, then in the second phase......Concurrent data structures synchronized with locks do not scale well with the number of threads. As more scalable alternatives, concurrent data structures and algorithms based on widely available, however advanced, atomic operations have been proposed. These data structures allow for correct...

  5. Control of photon storage time using phase locking.

    Science.gov (United States)

    Ham, Byoung S

    2010-01-18

    A photon echo storage-time extension protocol is presented by using a phase locking method in a three-level backward propagation scheme, where phase locking serves as a conditional stopper of the rephasing process in conventional two-pulse photon echoes. The backward propagation scheme solves the critical problems of extremely low retrieval efficiency and pi rephasing pulse-caused spontaneous emission noise in photon echo based quantum memories. The physics of the storage time extension lies in the imminent population transfer from the excited state to an auxiliary spin state by a phase locking control pulse. We numerically demonstrate that the storage time is lengthened by spin dephasing time.

  6. Testing ultrafast mode-locking at microhertz relative optical linewidth.

    Science.gov (United States)

    Martin, Michael J; Foreman, Seth M; Schibli, T R; Ye, Jun

    2009-01-19

    We report new limits on the phase coherence of the ultrafast mode-locking process in an octave-spanning Ti:sapphire comb.We find that the mode-locking mechanism correlates optical phase across a full optical octave with less than 2.5 microHZ relative linewidth. This result is at least two orders of magnitude below recent predictions for quantum-limited individual comb-mode linewidths, verifying that the mode-locking mechanism strongly correlates quantum noise across the comb spectrum.

  7. Temperature-insensitive laser frequency locking near absorption lines

    International Nuclear Information System (INIS)

    Kostinski, Natalie; Olsen, Ben A.; Marsland, Robert III; McGuyer, Bart H.; Happer, William

    2011-01-01

    Combined magnetically induced circular dichroism and Faraday rotation of an atomic vapor are used to develop a variant of the dichroic atomic vapor laser lock that eliminates lock sensitivity to temperature fluctuations of the cell. Operating conditions that eliminate first-order sensitivity to temperature fluctuations can be determined by low-frequency temperature modulation. This temperature-insensitive gyrotropic laser lock can be accurately understood with a simple model, that is in excellent agreement with observations in potassium vapor at laser frequencies in a 2 GHz range about the 770.1 nm absorption line. The methods can be readily adapted for other absorption lines.

  8. Testing ultrafast mode-locking at microhertz relative optical linewidth

    OpenAIRE

    Martin, Michael J.; Foreman, Seth M.; Schibli, T. R.; Ye, Jun

    2008-01-01

    We report new limits on the phase coherence of the ultrafast mode-locking process in an octave-spanning Ti:sapphire comb. We find that the mode-locking mechanism correlates optical phase across a full optical octave with less than 2.5 micro Hz relative linewidth. This result is at least two orders of magnitude below recent predictions for quantum-limited individual comb-mode linewidths, verifying that the mode-locking mechanism strongly correlates quantum noise across the comb spectrum.

  9. Tilt-tuned etalon locking for tunable laser stabilization.

    Science.gov (United States)

    Gibson, Bradley M; McCall, Benjamin J

    2015-06-15

    Locking to a fringe of a tilt-tuned etalon provides a simple, inexpensive method for stabilizing tunable lasers. Here, we describe the use of such a system to stabilize an external-cavity quantum cascade laser; the locked laser has an Allan deviation of approximately 1 MHz over a one-second integration period, and has a single-scan tuning range of approximately 0.4  cm(-1). The system is robust, with minimal alignment requirements and automated lock acquisition, and can be easily adapted to different wavelength regions or more stringent stability requirements with minor alterations.

  10. Development of the Lock Protocol for DEPSKY Storage System

    Directory of Open Access Journals (Sweden)

    NASCIMENTO, P. S.

    2015-06-01

    Full Text Available Data management in environments based on several clouds (cloud-of-clouds should be dependable and secure. DEPSKY may assure that characteristics through mechanisms as cryptography and data replication, however DEPSKY does not support concurrent writing, a desirable functionality for many applications. This paper presents the development and a performance analysis of a lock algorithmfor DEPSKY storage system. The paper also presents validation test and performance test of the algorithm. Such protocol allows concurrent writing, through a low contention lock mechanism that uses lock filesfi to dene who is allowed to write in a data unit.

  11. Squeezing in an injection-locked semiconductor laser

    Science.gov (United States)

    Inoue, S.; Machida, S.; Yamamoto, Y.; Ohzu, H.

    1993-09-01

    The intensity-noise properties of an injection-locked semiconductor laser were studied experimentally. The constant-current-driven semiconductor laser producing the amplitude-squeezed state whose intensity noise was reduced below the standard quantum limit (SQL) by 0.72 dB was injection-locked by an external master laser. The measured intensity-noise level of the injection-locked semiconductor laser was 0.91 dB below the SQL. This experimental result indicates that a phase-coherent amplitude-squeezed state or squeezed vacuum state together with a reference local oscillator wave can be generated directly by semiconductor laser systems.

  12. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    Science.gov (United States)

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les

  13. ''Old'' locked inflation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang; Piao, Yun-Song [College of Physical Sciences, Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Si, Zong-Guo, E-mail: liuyangbyf@mail.sdu.edu.cn, E-mail: yspiao@gucas.ac.cn, E-mail: zgsi@sdu.edu.cn [Department of Physics, Shandong University, Jinan 250100 (China)

    2009-05-15

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' {phi}. Instead of rolling down along the potential, the {phi} field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape.

  14. Towards automatic proofs of lock-free algorithms

    OpenAIRE

    Fejoz , Loïc; Merz , Stephan

    2008-01-01

    International audience; The verification of lock-free data structures has traditionally been considered as difficult. We propose a formal model for describing such algorithms. The verification conditions generated from this model can often be handled by automatic theorem provers.

  15. Experimental study on working characteristics of density lock

    International Nuclear Information System (INIS)

    Sun Furong; Yan Changqi; Gu Haifeng

    2011-01-01

    The working principle of density lock was introduced in this paper, and the experimental loop was built so that researches on working performance of density lock in the system were done at steady-state operation and pump trip conditions. The results show that at steady-state operation conditions, density lock can keep close in a long run, which will separate passive residual heat removal circuit from primary circuit. As a result, passive residual heat removal circuit is in the non-operating conditions, which dose not influence normal operation of reactors. At the pump trip conditions, density lock can be automatically opened quickly, which will make primary and passive residual heat removal system communicated. The natural circulation is well established in the two systems, and is enough to ensure removal of residual heat. (authors)

  16. Active stabilization of a diode laser injection lock

    Energy Technology Data Exchange (ETDEWEB)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep [Department of Physics, University of Washington, P.O. Box 351560, Seattle, Washington 98195-1560 (United States)

    2016-06-15

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  17. Active stabilization of a diode laser injection lock.

    Science.gov (United States)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-06-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  18. Development of thermal actuators with multi-locking positions

    Science.gov (United States)

    Luo, J. K.; Zhu, Y.; Fu, Y. Q.; Flewitt, A. J.; Spearing, S. M.; Miao, J. M.; Milne, W. I.

    2006-04-01

    To reduce power consumption and operation temperature for micro-thermal actuators, metal-based micro-mechanical locks with multi-locking positions were analyzed and fabricated. The micro-locks consist of two or three U-shaped thermal actuators. The devices were made by a single mask process using electroplated Ni as the active material. Tests showed that the metal based thermal actuators deliver a maximum displacement of ~20µm at a much lower temperature than that of Si-based actuators. However Ni-actuators showed a severe back bending, which increases with increasing applied power. The temperature to initiate the back bending is as low as ~240°C. Back bending increases the distance between the two actuators, and leads to locking function failure. For practical application, Ni-based thermal actuators must be operated below 200°C.

  19. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially

  20. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... above who presented within 2 weeks of sustaining closed femoral shaft fractures ... tweak, and build upon the work non-commercially, as long as the author is ... was compressed, and proximal locking screws were then.

  1. Self-mode-locked Nd3+:YAG laser

    International Nuclear Information System (INIS)

    Komarov, A K; Komarov, K P; Kuch'yanov, Aleksandr S

    2003-01-01

    Self-mode-locking was observed in a Nd 3+ :YAG laser with a negative feedback without introducing any nonlinear elements into the laser cavity. The laser generates during pumping 300 - 500-ps single pulses on an axial period. (lasers)

  2. Mode-Locked Semiconductor Lasers for Optical Communication Systems

    DEFF Research Database (Denmark)

    Yvind, Kresten; Larsson, David; Oxenløwe, Leif Katsuo

    2005-01-01

    We present investigations on 10 and 40 GHz monolithic mode-locked lasers for applications in optical communications systems. New all-active lasers with one to three quantum wells have been designed, fabricated and characterized....

  3. Development of Phase Lock Loop System for Synchronisation of a ...

    African Journals Online (AJOL)

    Akorede

    KEYWORDS: Phase locked loop (PLL), grid synchronisation, simulations, PI regulator, hybrid system. .... system. AC. - D. C co nv erter. DC-DC converter. DC. - AC co nverter. Load ... The box named Discrete Transfer Fcn is the PI-regulator.

  4. Actuator assembly including a single axis of rotation locking member

    Science.gov (United States)

    Quitmeyer, James N.; Benson, Dwayne M.; Geck, Kellan P.

    2009-12-08

    An actuator assembly including an actuator housing assembly and a single axis of rotation locking member fixedly attached to a portion of the actuator housing assembly and an external mounting structure. The single axis of rotation locking member restricting rotational movement of the actuator housing assembly about at least one axis. The single axis of rotation locking member is coupled at a first end to the actuator housing assembly about a Y axis and at a 90.degree. angle to an X and Z axis providing rotation of the actuator housing assembly about the Y axis. The single axis of rotation locking member is coupled at a second end to a mounting structure, and more particularly a mounting pin, about an X axis and at a 90.degree. angle to a Y and Z axis providing rotation of the actuator housing assembly about the X axis. The actuator assembly is thereby restricted from rotation about the Z axis.

  5. Firearm Safety Locks: Federal Agency Implementation of the Presidential Directive

    National Research Council Canada - National Science Library

    1998-01-01

    ... deaths among children ages 5 to 14. In order to have the federal government serve as an example of gun safety, the President required that a safety lock device be provided with each handgun issued to federal law enforcement officers...

  6. Active stabilization of a diode laser injection lock

    International Nuclear Information System (INIS)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  7. Design and Performance Test of Locking Curved-Nut

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Min Cheol; Kang, Ho Sung; Kim, Do Yeop; Lee, Suk Yong; Lee, Eung Suk [Chungbuk Nat’l Univ., Cheongju (Korea, Republic of); Jeong, Hui Jong [Viblock Company, Cheongwon (Korea, Republic of)

    2017-03-15

    Many types of locking nut are commercializing in the various industries where has heavy vibration. Because Nut's loosing causes a serious accident. But the most locking nuts are too expensive as the complicate manufacturing process. In this study, we design the new type of locking nut, 'Curved-Nut' that is relatively simple making process. We study a relation between the elastic energy and the nut loosing mechanism. So it is analysed, the elastic energy of Curved-Nut comparing with the locking test. The Curved-Nut was manufactured on the commercial nut using a milling tool with horizontal cutting, one or two time under the nut. As the result, the more elastic energy the more prevent the loosing of the nut. We verified the performance of the loosing nut using the vibration testing equipment (NAS3350).

  8. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  9. Vortex locking in direct numerical simulations of quantum turbulence.

    Science.gov (United States)

    Morris, Karla; Koplik, Joel; Rouson, Damian W I

    2008-07-04

    Direct numerical simulations are used to examine the locking of quantized superfluid vortices and normal fluid vorticity in evolving turbulent flows. The superfluid is driven by the normal fluid, which undergoes either a decaying Taylor-Green flow or a linearly forced homogeneous isotropic turbulent flow, although the back reaction of the superfluid on the normal fluid flow is omitted. Using correlation functions and wavelet transforms, we present numerical and visual evidence for vortex locking on length scales above the intervortex spacing.

  10. Enforced Electrical Neutrality of the Color-Flavor Locked Phase

    International Nuclear Information System (INIS)

    Rajagopal, Krishna; Wilczek, Frank

    2001-01-01

    We demonstrate that quark matter in the color-flavor locked phase of QCD is rigorously electrically neutral, despite the unequal quark masses, and even in the presence of an electron chemical potential. As long as the strange quark mass and the electron chemical potential do not preclude the color-flavor locked phase, quark matter is automatically neutral. No electrons are required and none are admitted

  11. Active Stabilization of a Diode Laser Injection Lock

    OpenAIRE

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudde...

  12. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  13. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  14. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  15. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  16. Technique for Determining Lock Coefficient of Differential "Quif"

    Directory of Open Access Journals (Sweden)

    A. B. Fominyh

    2015-01-01

    Full Text Available Increasing the traction qualities of cars on the black ice and snow-covered roads is a relevant task. There are two ways to solve this task, i.e. optimize distribution of the power stream between the driving wheels of the car; introduce a differential (differentials of the increased friction in transmission.Now, an installation of the increased friction differential in transmission is the most widespread measure to increase traction properties of cars. The differential of design "Quif" is one of such differentials. To estimate the efficiency degree of using such a differential is possible either experimentally or theoretically. In case of theoretically determined usefulness of this differential design, as an estimate indicator of the differential installation in transmission a coefficient of lock is accepted.The article considers an algorithm and a technique to calculate a lock coefficient of the differential design "Quif" allowing us to define numeric values of the lock coefficient of such differential at designing stage. It also considers how the lock coefficient depends on the gearing angle and tilt angle of the gear wheel teeth of differential. The given estimating algorithm of designated parameter of differential has more logical and compact structure with regard to the known ones. The lock coefficient values calculated by the offered technique differ from the experimental data by no more than 12%. Taking into account abovementioned, the presented technique for calculating lock coefficient of differential "Quif" is advisable for practical application.

  17. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  18. Experimental implementation of phase locking in a nonlinear interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hailong; Jing, Jietai, E-mail: jtjing@phy.ecnu.edu.cn [State Key Laboratory of Precision Spectroscopy, Department of Physics, East China Normal University, Shanghai 200062 (China); Marino, A. M. [Homer L. Dodge Department of Physics and Astronomy, The University of Oklahoma, 440 West Brooks Street, Norman, Oklahoma 73019 (United States)

    2015-09-21

    Based upon two cascade four-wave mixing processes in two identical hot rubidium vapor cells, a nonlinear interferometer has been experimentally realized [Jing et al., Appl. Phys. Lett. 99, 011110 (2011); Hudelist et al., Nat. Commun. 5, 3049 (2014)]. It has a higher degree of phase sensitivity than a traditional linear interferometer and has many potential applications in quantum metrology. Phase locking of the nonlinear interferometer is needed before it can find its way into applications. In this letter, we investigate the experimental implementation of phase locking of the relative phase between the three beams at different frequencies involved in such a nonlinear interferometer. We have utilized two different methods, namely, beat note locking and coherent modulation locking. We find that coherent modulation locking can achieve much better phase stability than beat note locking in our system. Our results pave the way for real applications of a nonlinear interferometer in precision measurement and quantum manipulation, for example, phase control in phase-sensitive N-wave mixing process, N-port nonlinear interferometer and quantum-enhanced real-time phase tracking.

  19. Locked doors in acute inpatient psychiatry: a literature review.

    Science.gov (United States)

    van der Merwe, M; Bowers, L; Jones, J; Simpson, A; Haglund, K

    2009-04-01

    Many acute inpatient psychiatric wards in the UK are permanently locked, although this is contrary to the current Mental Health Act Code of Practice. To conduct a literature review of empirical articles concerning locked doors in acute psychiatric inpatient wards, an extensive literature search was performed in SAGE Journals Online, EBM Reviews, British Nursing Index, CINAHL, EMBASE Psychiatry, International Bibliography of the Social Sciences, Ovid MEDLINE, PsycINFO and Google, using the search terms 'open$', 'close$', '$lock$', 'door', 'ward', 'hospital', 'psychiatr', 'mental health', 'inpatient' and 'asylum'. A total of 11 empirical papers were included in the review. Both staff and patients reported advantages (e.g. preventing illegal substances from entering the ward and preventing patients from absconding and harming themselves or others) and disadvantages (e.g. making patients feel depressed, confined and creating extra work for staff) regarding locked doors. Locked wards were associated with increased patient aggression, poorer satisfaction with treatment and more severe symptoms. The limited literature available showed the urgent need for research to determine the real effects of locked doors in inpatient psychiatry.

  20. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  1. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  2. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  3. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  4. EQUATORIAL SUPERROTATION ON TIDALLY LOCKED EXOPLANETS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Polvani, Lorenzo M.

    2011-01-01

    The increasing richness of exoplanet observations has motivated a variety of three-dimensional (3D) atmospheric circulation models of these planets. Under strongly irradiated conditions, models of tidally locked, short-period planets (both hot Jupiters and terrestrial planets) tend to exhibit a circulation dominated by a fast eastward, or 'superrotating', jet stream at the equator. When the radiative and advection timescales are comparable, this phenomenon can cause the hottest regions to be displaced eastward from the substellar point by tens of degrees longitude. Such an offset has been subsequently observed on HD 189733b, supporting the possibility of equatorial jets on short-period exoplanets. Despite its relevance, however, the dynamical mechanisms responsible for generating the equatorial superrotation in such models have not been identified. Here, we show that the equatorial jet results from the interaction of the mean flow with standing Rossby waves induced by the day-night thermal forcing. The strong longitudinal variations in radiative heating-namely intense dayside heating and nightside cooling-trigger the formation of standing, planetary-scale equatorial Rossby and Kelvin waves. The Rossby waves develop phase tilts that pump eastward momentum from high latitudes to the equator, thereby inducing equatorial superrotation. We present an analytic theory demonstrating this mechanism and explore its properties in a hierarchy of one-layer (shallow-water) calculations and fully 3D models. The wave-mean-flow interaction produces an equatorial jet whose latitudinal width is comparable to that of the Rossby waves, namely the equatorial Rossby deformation radius modified by radiative and frictional effects. For conditions typical of synchronously rotating hot Jupiters, this length is comparable to a planetary radius, explaining the broad scale of the equatorial jet obtained in most hot-Jupiter models. Our theory illuminates the dependence of the equatorial jet

  5. El concepto de Derecho en Locke

    Directory of Open Access Journals (Sweden)

    Diego Alejandro Fernández Peychaux

    2011-01-01

    Full Text Available El siguiente artículo aspira a ser un aporte para la comprensión del modo en que John Locke establece la relación entre los hombres y la sociedad. De acuerdo con la tradición contractualista en la que el autor se inscribe, se pretende recorrer un camino con dos etapas. En la primera, se busca establecer bien el significado del concepto de derecho, bien su relación con los deberes que surgen de la ley de naturaleza. En un segundo momento, se buscará identificar la relación existente entre los derechos/deberes y el concepto de inalienabilidad, para así comprender no ya la relación interna de los derechos/deberes individuales, sino cómo interactúan estos con los del prójimo y la comunidad en la que viven los hombres. Para ello se buscará argumentar que la inalienabilidad de los derechos del hombre, excluido el derecho a la vida, no se fundamenta en el propio derecho, sino en la relación de este con el bien más fundamental que buscan preservar, n.b. autopreservación. De este modo, se establece una suerte de escala de derechos, donde a medida que se desciende se amplía el poder de enajenación, siempre y cuando represente un aumento de las expectativas de mejorar las posibilidades de preservación.

  6. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  7. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  8. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  9. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  10. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  11. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  12. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  13. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  14. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  15. The Synergistic Effect of Leukocyte Platelet-Rich Fibrin and Micrometer/Nanometer Surface Texturing on Bone Healing around Immediately Placed Implants: An Experimental Study in Dogs

    Science.gov (United States)

    Neiva, Rodrigo F.; Gil, Luiz Fernando; Tovar, Nick; Janal, Malvin N.; Marao, Heloisa Fonseca; Pinto, Nelson; Coelho, Paulo G.

    2016-01-01

    Aims. This study evaluated the effects of L-PRF presence and implant surface texture on bone healing around immediately placed implants. Methods. The first mandibular molars of 8 beagle dogs were bilaterally extracted, and implants (Blossom™, Intra-Lock International, Boca Raton, FL) were placed in the mesial or distal extraction sockets in an interpolated fashion per animal. Two implant surfaces were distributed per sockets: (1) dual acid-etched (DAE, micrometer scale textured) and (2) micrometer/nanometer scale textured (Ossean™ surface). L-PRF (Intraspin system, Intra-Lock International) was placed in a split-mouth design to fill the macrogap between implant and socket walls on one side of the mandible. The contralateral side received implants without L-PRF. A mixed-model ANOVA (at α = 0.05) evaluated the effect of implant surface, presence of L-PRF, and socket position (mesial or distal), individually or in combination on bone area fraction occupancy (BAFO). Results. BAFO values were significantly higher for the Ossean relative to the DAE surface on the larger mesial socket. The presence of L-PRF resulted in higher BAFO. The Ossean surface and L-PRF presence resulted in significantly higher BAFO. Conclusion. L-PRF and the micro-/nanometer scale textured surface resulted in increased bone formation around immediately placed implants. PMID:28042577

  16. The Synergistic Effect of Leukocyte Platelet-Rich Fibrin and Micrometer/Nanometer Surface Texturing on Bone Healing around Immediately Placed Implants: An Experimental Study in Dogs

    Directory of Open Access Journals (Sweden)

    Rodrigo F. Neiva

    2016-01-01

    Full Text Available Aims. This study evaluated the effects of L-PRF presence and implant surface texture on bone healing around immediately placed implants. Methods. The first mandibular molars of 8 beagle dogs were bilaterally extracted, and implants (Blossom™, Intra-Lock International, Boca Raton, FL were placed in the mesial or distal extraction sockets in an interpolated fashion per animal. Two implant surfaces were distributed per sockets: (1 dual acid-etched (DAE, micrometer scale textured and (2 micrometer/nanometer scale textured (Ossean™ surface. L-PRF (Intraspin system, Intra-Lock International was placed in a split-mouth design to fill the macrogap between implant and socket walls on one side of the mandible. The contralateral side received implants without L-PRF. A mixed-model ANOVA (at α=0.05 evaluated the effect of implant surface, presence of L-PRF, and socket position (mesial or distal, individually or in combination on bone area fraction occupancy (BAFO. Results. BAFO values were significantly higher for the Ossean relative to the DAE surface on the larger mesial socket. The presence of L-PRF resulted in higher BAFO. The Ossean surface and L-PRF presence resulted in significantly higher BAFO. Conclusion. L-PRF and the micro-/nanometer scale textured surface resulted in increased bone formation around immediately placed implants.

  17. Locking screw apparatus and method for underwater remote replacement

    International Nuclear Information System (INIS)

    Balog, L.J.

    1987-01-01

    A method is described for locking in place a screw which secures together first and second structures in the internal region of a nuclear reactor core. The first structure has a screw bore with a counterbore portion formed in an outer surface. The method comprises the steps of: forming a lateral recess in the counterbore portion and spaced from the outer surface, providing an elongated screw having an enlarged shoulder flange and an angular drive head with a lateral width substantially less than that of the counterbore portion, disposing the screw through the screw bore in threaded engagement with the second structure and with the shoulder rotatably seated in the counterbore portion. This provides a locking member having an angular opening and disposing it in the counterbore portion against the flange with the drive head received in the opening for engagement with the locking member to prevent rotation. This deforms a portion of the locking member into the recess for engagement to prevent movement of the locking member with respect to the first structure

  18. Evolution of the Generic Lock System at Jefferson Lab

    International Nuclear Information System (INIS)

    Brian Bevins; Yves Roblin

    2003-01-01

    The Generic Lock system is a software framework that allows highly flexible feedback control of large distributed systems. It allows system operators to implement new feedback loops between arbitrary process variables quickly and with no disturbance to the underlying control system. Several different types of feedback loops are provided and more are being added. This paper describes the further evolution of the system since it was first presented at ICALEPCS 2001 and reports on two years of successful use in accelerator operations. The framework has been enhanced in several key ways. Multiple-input, multiple-output (MIMO) lock types have been added for accelerator orbit and energy stabilization. The general purpose Proportional-Integral-Derivative (PID) locks can now be tuned automatically. The generic lock server now makes use of the Proxy IOC (PIOC) developed at Jefferson Lab to allow the locks to be monitored from any EPICS Channel Access aware client. (Previously clients had to be Cdev aware.) The dependency on the Qt XML parser has been replaced with the freely available Xerces DOM parser from the Apache project

  19. Locked-in: the syndrome as depicted in literature.

    Science.gov (United States)

    Haan, Joost

    2013-01-01

    Protagonists who are locked-in can be found throughout fiction, probably because being locked-in serves as a strong philosophical metaphor for human existence. In this chapter, three protagonists who are locked-in due to physical/medical reasons will be described. The fictitious stories of Noirtier from The Count of Monte Cristo by Alexandre Dumas and that of Madame Raquin from Thérèse Raquin by Émile Zola are followed by the real-life story of Jean-Dominique Bauby's The Diving Bell and the Butterfly. Dumas' Noirtier is considered the first description of the locked-in syndrome in literature, and Madame Raquin appears to be locked-in also, but her description leaves many questions. Bauby's autopathography is chosen from many several similar discourses as it contains cross-references to Noirtier, Dumas' prototype of the syndrome, but also because it is of high literary value. The similarities and remarkable differences between these three case reports of this existentialistically important state of being will be highlighted, with an emphasis on the focus of their narratives. © 2013 Elsevier B.V. All rights reserved.

  20. Mutual phase-locking of planar nano-oscillators

    Directory of Open Access Journals (Sweden)

    K. Y. Xu

    2014-06-01

    Full Text Available Characteristics of phase-locking between Gunn effect-based planar nano-oscillators are studied using an ensemble Monte Carlo (EMC method. Directly connecting two oscillators in close proximity, e.g. with a channel distance of 200 nm, only results in incoherent oscillations. In order to achieve in-phase oscillations, additional considerations must be taken into account. Two coupling paths are shown to exist between oscillators. One coupling path results in synchronization and the other results in anti-phase locking. The coupling strength through these two paths can be adjusted by changing the connections between oscillators. When two identical oscillators are in the anti-phase locking regime, fundamental components of oscillations are cancelled. The resulting output consists of purely second harmonic oscillations with a frequency of about 0.66 THz. This type of second harmonic generation is desired for higher frequency applications since no additional filter system is required. This transient phase-locking process is further analyzed using Adler's theory. The locking range is extracted, and a criterion for the channel length difference required for realizing phased arrays is obtained. This work should aid in designing nano-oscillator arrays for high power applications and developing directional transmitters for wireless communications.

  1. APR1400 Locked Rotor Transient Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun

    2007-01-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR

  2. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  3. APR1400 Locked Rotor Transient Analysis using KNAP

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR.

  4. CLIMATE INSTABILITY ON TIDALLY LOCKED EXOPLANETS

    International Nuclear Information System (INIS)

    Kite, Edwin S.; Manga, Michael; Gaidos, Eric

    2011-01-01

    Feedbacks that can destabilize the climates of synchronously rotating rocky planets may arise on planets with strong day-night surface temperature contrasts. Earth-like habitable planets maintain stable surface liquid water over geologic time. This requires equilibrium between the temperature-dependent rate of greenhouse-gas consumption by weathering, and greenhouse-gas resupply by other processes. Detected small-radius exoplanets, and anticipated M-dwarf habitable-zone rocky planets, are expected to be in synchronous rotation (tidally locked). In this paper, we investigate two hypothetical feedbacks that can destabilize climate on planets in synchronous rotation. (1) If small changes in pressure alter the temperature distribution across a planet's surface such that the weathering rate goes up when the pressure goes down, a runaway positive feedback occurs involving increasing weathering rate near the substellar point, decreasing pressure, and increasing substellar surface temperature. We call this feedback enhanced substellar weathering instability (ESWI). (2) When decreases in pressure increase the fraction of surface area above the melting point (through reduced advective cooling of the substellar point), and the corresponding increase in volume of liquid causes net dissolution of the atmosphere, a further decrease in pressure will occur. This substellar dissolution feedback can also cause a runaway climate shift. We use an idealized energy balance model to map out the conditions under which these instabilities may occur. In this simplified model, the weathering runaway can shrink the habitable zone and cause geologically rapid 10 3 -fold atmospheric pressure shifts within the habitable zone. Mars may have undergone a weathering runaway in the past. Substellar dissolution is usually a negative feedback or weak positive feedback on changes in atmospheric pressure. It can only cause runaway changes for small, deep oceans and highly soluble atmospheric gases. Both

  5. CLIMATE INSTABILITY ON TIDALLY LOCKED EXOPLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Kite, Edwin S.; Manga, Michael [Department of Earth and Planetary Science, University of California at Berkeley, CA 94720 (United States); Gaidos, Eric, E-mail: edwin.kite@gmail.com [Department of Geology and Geophysics, University of Hawaii at Manoa, Honolulu, HI 96822 (United States)

    2011-12-10

    Feedbacks that can destabilize the climates of synchronously rotating rocky planets may arise on planets with strong day-night surface temperature contrasts. Earth-like habitable planets maintain stable surface liquid water over geologic time. This requires equilibrium between the temperature-dependent rate of greenhouse-gas consumption by weathering, and greenhouse-gas resupply by other processes. Detected small-radius exoplanets, and anticipated M-dwarf habitable-zone rocky planets, are expected to be in synchronous rotation (tidally locked). In this paper, we investigate two hypothetical feedbacks that can destabilize climate on planets in synchronous rotation. (1) If small changes in pressure alter the temperature distribution across a planet's surface such that the weathering rate goes up when the pressure goes down, a runaway positive feedback occurs involving increasing weathering rate near the substellar point, decreasing pressure, and increasing substellar surface temperature. We call this feedback enhanced substellar weathering instability (ESWI). (2) When decreases in pressure increase the fraction of surface area above the melting point (through reduced advective cooling of the substellar point), and the corresponding increase in volume of liquid causes net dissolution of the atmosphere, a further decrease in pressure will occur. This substellar dissolution feedback can also cause a runaway climate shift. We use an idealized energy balance model to map out the conditions under which these instabilities may occur. In this simplified model, the weathering runaway can shrink the habitable zone and cause geologically rapid 10{sup 3}-fold atmospheric pressure shifts within the habitable zone. Mars may have undergone a weathering runaway in the past. Substellar dissolution is usually a negative feedback or weak positive feedback on changes in atmospheric pressure. It can only cause runaway changes for small, deep oceans and highly soluble atmospheric

  6. The free energy of locking a ring: Changing a deoxyribonucleoside to a locked nucleic acid.

    Science.gov (United States)

    Xu, You; Villa, Alessandra; Nilsson, Lennart

    2017-06-05

    Locked nucleic acid (LNA), a modified nucleoside which contains a bridging group across the ribose ring, improves the stability of DNA/RNA duplexes significantly, and therefore is of interest in biotechnology and gene therapy applications. In this study, we investigate the free energy change between LNA and DNA nucleosides. The transformation requires the breaking of the bridging group across the ribose ring, a problematic transformation in free energy calculations. To address this, we have developed a 3-step (easy to implement) and a 1-step protocol (more efficient, but more complicated to setup), for single and dual topologies in classical molecular dynamics simulations, using the Bennett Acceptance Ratio method to calculate the free energy. We validate the approach on the solvation free energy difference for the nucleosides thymidine, cytosine, and 5-methyl-cytosine. © 2017 The Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc. © 2017 The Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc.

  7. A Digital Phase Lock Loop for an External Cavity Diode Laser

    Science.gov (United States)

    Wang, Xiao-Long; Tao, Tian-Jiong; Cheng, Bing; Wu, Bin; Xu, Yun-Fei; Wang, Zhao-Ying; Lin, Qiang

    2011-08-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems.

  8. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  9. Acute low-level alcohol consumption reduces phase locking of event-related oscillations in rodents.

    Science.gov (United States)

    Amodeo, Leslie R; Wills, Derek N; Ehlers, Cindy L

    2017-07-14

    Event-related oscillations (EROs) are rhythmic changes that are evoked by a sensory and/or cognitive stimulus that can influence the dynamics of the EEG. EROs are defined by the decomposition of the EEG signal into magnitude (energy) and phase information and can be elicited in both humans and animals. EROs have been linked to several relevant genes associated with ethanol dependence phenotypes in humans and are altered in selectively bred alcohol-preferring rats. However, pharmacological studies are only beginning to emerge investigating the impact low intoxicating doses of ethanol can have on event-related neural oscillations. The main goal of this study was to investigate the effects of low levels of voluntary consumption of ethanol, in rats, on phase locking of EROs in order to give further insight into the acute intoxicating effects of ethanol on the brain. To this end, we allow rats to self-administer unsweetened 20% ethanol over 15 intermittent sessions. This method results in a stable low-dose consumption of ethanol. Using an auditory event-related potential "oddball" paradigm, we investigated the effects of alcohol on the phase variability of EROs from electrodes implanted into the frontal cortex, dorsal hippocampus, and amygdala. We found that intermittent ethanol self-administration was sufficient to produce a significant reduction in overall intraregional synchrony across all targeted regions. These data suggest that phase locking of EROs within brain regions known to be impacted by alcohol may represent a sensitive biomarker of low levels of alcohol intoxication. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  11. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  12. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    were with fracture on right side and 8 on left side. 3 patients had associated injuries. Of them, 2 patients had comminuted fracture of patella on same side and 1 had ipsilateral tibial fracture. All patients were treated with open reduction and internal fixation. All patients were operated within 8 days. Average time duration of surgery was 101 minutes with shortest duration being 80 mins. and longest being 120 mins. The size of plate was selected based on the type of fracture. Of 20 patients, 14 patients (70% showed radiological union within 18 weeks. No patients had implant failure. Average flexion achieved in this study was 105 degrees with more than 45% patients having knee range of motion more than 110 degrees. Average knee extensor lag in this study was 5.8 degrees. Out of 20 patients, 3 had shortening, 2 patients with shortening of 15 mm and 1 shortening of 10 mm. In this study, 3 patients had significant virus and 3 patients had valgus malalignment with 2 patients had deep infection, which was treated with debridement and antibiotics. The duration of follow-up ranged from 3 months to 18 months. CONCLUSION Locking compression plate is the optimal tool for many fractures in distal femur. It provided rigid fixation in that region of the femur, where a widening canal, thin cortices and frequently poor bone stock, which make fixation difficult. Minimally-invasive surgical exposure for plate placement requires significantly less periosteal stripping and soft tissue exposure than that of other techniques. Early mobilisation postoperatively achieves a greater range of motion of knee, which is of paramount importance.

  13. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  14. Adaptive Injection-locking Oscillator Array for RF Spectrum Analysis

    International Nuclear Information System (INIS)

    Leung, Daniel

    2011-01-01

    A highly parallel radio frequency receiver using an array of injection-locking oscillators for on-chip, rapid estimation of signal amplitudes and frequencies is considered. The oscillators are tuned to different natural frequencies, and variable gain amplifiers are used to provide negative feedback to adapt the locking band-width with the input signal to yield a combined measure of input signal amplitude and frequency detuning. To further this effort, an array of 16 two-stage differential ring oscillators and 16 Gilbert-cell mixers is designed for 40-400 MHz operation. The injection-locking oscillator array is assembled on a custom printed-circuit board. Control and calibration is achieved by on-board microcontroller.

  15. Restitution in the context of institutional lock-in

    Directory of Open Access Journals (Sweden)

    Załęczna Magdalena

    2014-01-01

    Full Text Available This article presents the problem of lack of restitution in Poland in the political, social and economic context. The author presents the theory of institutional lock-in, referring to the hitherto course of the political, social and economic transformation processes in Poland. She is focusing on the research problem in form of an institutional lock-in on the route to general restitution process. The author examines the path shaping and path dependence to understand the current negative attitude toward restitution presented by the government and society. The author also indicates the costs caused by lack of restitution. Through analysis of past attempts of restitution regulations the author indicates the most important flashpoints. A hypothesis constructed by the author focuses on the negative effects of institutional lock-in, lack of restitution increases transaction costs influencing the Polish economy. The study is based on the legal documents and the results of public opinion polls.

  16. Beating quantum limits in interferometers with quantum locking of mirrors

    International Nuclear Information System (INIS)

    Heidmann, Antoine; Courty, Jean-Michel; Pinard, Michel; Lebars, Julien

    2004-01-01

    The sensitivity in interferometric measurements such as those made by gravitational-wave detectors is ultimately limited by the quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-wave interferometers with Fabry-Perot cavities in each arm, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer

  17. Injection Locking of a Semiconductor Double Quantum Dot Micromaser.

    Science.gov (United States)

    Liu, Y-Y; Stehlik, J; Gullans, M J; Taylor, J M; Petta, J R

    2015-11-01

    Emission linewidth is an important figure of merit for masers and lasers. We recently demonstrated a semiconductor double quantum dot (DQD) micromaser where photons are generated through single electron tunneling events. Charge noise directly couples to the DQD energy levels, resulting in a maser linewidth that is more than 100 times larger than the Schawlow-Townes prediction. Here we demonstrate a linewidth narrowing of more than a factor 10 by locking the DQD emission to a coherent tone that is injected to the input port of the cavity. We measure the injection locking range as a function of cavity input power and show that it is in agreement with the Adler equation. The position and amplitude of distortion sidebands that appear outside of the injection locking range are quantitatively examined. Our results show that this unconventional maser, which is impacted by strong charge noise and electron-phonon coupling, is well described by standard laser models.

  18. Stability improvement for coil position locking of joule balance

    Science.gov (United States)

    Bai, Yang; Liu, Yongmeng; Lu, Yunfeng; Hu, Pengcheng; Wang, Dawei; Li, Zhengkun; Tan, Jiubin; Zhang, Zhonghua

    2017-08-01

    The relative vertical position locking precision between the exciting and suspended coils is an important uncertainty for the Planck constant traceability in joule balance. In order to improve the relative vertical position locking precision, several stability experiments are conducted. The stability characteristics of the suspended and exciting coils are measured using a six-axis laser interferometer system; meanwhile, the effectiveness of the active vibration isolation table is measured using a vibration measurement sensor. The piezoelectric ceramic actuators with PID controller are used to compensate the relative vertical displacement drifts while a six-axis laser interferometer system is used to measure the positions of two coils. Experimental results show that the relative vertical position is stably locked.

  19. Magnetized color flavor locked state and compact stars

    CERN Document Server

    Felipe, R Gonzalez; Martinez, A Perez

    2010-01-01

    The stability of the color flavor locked phase in the presence of a strong magnetic field is investigated within the phenomenological MIT bag model, taking into account the variation of the strange quark mass, the baryon density, the magnetic field, as well as the bag and gap parameters. It is found that the minimum value of the energy per baryon in a color flavor locked state at vanishing pressure is lower than the corresponding one for unpaired magnetized strange quark matter and, as the magnetic field increases, the energy per baryon decreases. This implies that magnetized color flavor locked matter is more stable and could become the ground state inside neutron stars. The mass-radius relation for such stars is also studied.

  20. Wavenumber locking and pattern formation in spatially forced systems

    International Nuclear Information System (INIS)

    Manor, Rotem; Meron, Ehud; Hagberg, Aric

    2009-01-01

    We study wavenumber locking and pattern formation resulting from weak spatially periodic one-dimensional forcing of two-dimensional systems. We consider systems that produce stationary or traveling stripe patterns when unforced and apply forcing aligned with the stripes. Forcing at close to twice the pattern wavenumber selects, stabilizes, or creates resonant stripes locked at half the forcing wavenumber. If the mismatch between the forcing and pattern wavenumber is high we find that the pattern still locks but develops a wave vector component perpendicular to the forcing direction and forms rectangular and oblique patterns. When the unforced system supports traveling waves, resonant rectangular patterns remain stationary but oblique patterns travel in a direction orthogonal to the traveling waves.

  1. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  2. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  3. 75 FR 5071 - Mississippi L&D 21, LLC, Mississippi River No. 21 Hydropower Company Lock + TM

    Science.gov (United States)

    2010-02-01

    ... Lock + \\TM\\ Hydro Friends Fund XXXII, LLC; Notice of Preliminary Permit Applications Accepted for..., Lock + TM Hydro Friends Fund XXXII, LLC (Lock + Hydro) filed an application for a preliminary permit...

  4. Phase-locked flux-flow Josephson oscillator

    DEFF Research Database (Denmark)

    Ustinov, A. V.; Mygind, Jesper; Oboznov, V. A.

    1992-01-01

    We report on the observation of large rf induced steps due to phase-locking of unidirectional flux-flow motion in long quasi-one-dimensional Josephson junctions. The external microwave irradiation in the frequency range 62–77 GHz was applied from the edge of the junction at which the fluxons enter....... The dependence of the amplitude of the phase-locked step on external magnetic field and microwave power has been measured. The observed zero-crossing steps have potential application in Josephson voltage standards. A simple model for the flux-flow as determined by the microwave driven boundary gate at the edge...

  5. Cyclotomy and Ramanujan sums in quantum phase locking

    International Nuclear Information System (INIS)

    Planat, Michel; Rosu, Haret C.

    2003-01-01

    Phase-locking governs the phase noise in classical clocks through effects described in precise mathematical terms. We seek here a quantum counterpart of these effects by working in a finite Hilbert space. We use a coprimality condition to define phase-locked quantum states and the corresponding Pegg-Barnett type phase operator. Cyclotomic symmetries in matrix elements are revealed and related to Ramanujan sums in the theory of prime numbers. The employed mathematical procedures also emphasize the isomorphism between algebraic number theory and the theory of quantum entanglement

  6. Positioning and locking device for fuel pin to grid attachment

    International Nuclear Information System (INIS)

    Frick, T.M.; Wineman, A.L.

    1976-01-01

    A positioning and locking device for fuel pin to grid attachment provides an inexpensive means of positively positioning and locking the individual fuel pins which make up the driver fuel assemblies used in nuclear reactors. The device can be adapted for use with a currently used attachment grid assembly design and insures that the pins remain in their proper position throughout the in-reactor life of the assembly. This device also simplifies fuel bundle assembly in that a complete row of fuel pins can be added to the bundle during each step of assembly. 8 claims, 8 drawing figures

  7. Inter-comb synchronization by mode-to-mode locking

    Science.gov (United States)

    Chun, Byung Jae; Kim, Young-Jin; Kim, Seung-Woo

    2016-08-01

    Two combs of fiber femtosecond lasers are synchronized through the optical frequency reference created by injection-locking of a diode laser to a single comb mode. Maintaining a mHz-level narrow linewidth, the optical frequency reference permits two combs to be stabilized by mode-to-mode locking with a relative stability of 1.52  ×  10-16 at 10 s with a frequency slip of 2.46 mHz. This inter-comb synchronization can be utilized for applications such as dual-comb spectroscopy or ultra-short pulse synthesis without extra narrow-linewidth lasers.

  8. Microwave phase locking of Josephson-junction fluxon oscillators

    DEFF Research Database (Denmark)

    Salerno, M.; Samuelsen, Mogens Rugholm; Filatrella, G.

    1990-01-01

    Application of the classic McLaughlin-Scott soliton perturbation theory to a Josephson-junction fluxon subjected to a microwave field that interacts with the fluxon only at the junction boundaries reduces the problem of phase locking of the fluxon oscillation to the study of a two-dimensional fun......Application of the classic McLaughlin-Scott soliton perturbation theory to a Josephson-junction fluxon subjected to a microwave field that interacts with the fluxon only at the junction boundaries reduces the problem of phase locking of the fluxon oscillation to the study of a two...

  9. Lock-in imaging with synchronous digital mirror demodulation

    Science.gov (United States)

    Bush, Michael G.

    2010-04-01

    Lock-in imaging enables high contrast imaging in adverse conditions by exploiting a modulated light source and homodyne detection. We report results on a patent pending lock-in imaging system fabricated from commercial-off-theshelf parts utilizing standard cameras and a spatial light modulator. By leveraging the capabilities of standard parts we are able to present a low cost, high resolution, high sensitivity camera with applications in search and rescue, friend or foe identification (IFF), and covert surveillance. Different operating modes allow the same instrument to be utilized for dual band multispectral imaging or high dynamic range imaging, increasing the flexibility in different operational settings.

  10. Pre-Extreme Automotive Anti-Lock Brake Systems

    Directory of Open Access Journals (Sweden)

    V. G. Ivanov

    2004-01-01

    Full Text Available Designing of systems ensuring active safety of automobiles with intellectual functions requires usage of new control principles for wheel and automobile operation. One of such principles is a preextreme control strategy. Its aim is to ensure wheel work in pre-extreme, stable area of «tire grip coefficient wheel slip coefficient» dependence. The simplest realization of pre-extreme control in automotive anti-lock brake systems consists in the threshold and gradient algorithms. A comparative analysis of these algorithms which has been made on simulation results of bus braking with various anti-lock brake systems has revealed their high efficiency.

  11. Relaxation towards phase-locked dynamics in long Josephson junctions

    DEFF Research Database (Denmark)

    Salerno, M.; Grønbech-Jensen, Niels; Samuelsen, Mogens Rugholm

    1995-01-01

    We study the relaxation phenomenon towards phase-locked dynamics in long Josephson junctions. In particular the dependence of the relaxation frequency for the equal time of flight solution on the junction parameters is derived. The analysis is based on a phase-locked map and is compared with direct...... numerical experiments performed both on the map and on the perturbed sine-Gordon equation. As an interesting result we find that very close to a bifurcation the relaxation frequency is exactly equal to the half of the step frequency, i.e., the frequency characterizing the period-one solution....

  12. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  13. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  14. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  15. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  16. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  17. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  18. Taurolidine lock is superior to heparin lock in the prevention of catheter related bloodstream infections and occlusions.

    Directory of Open Access Journals (Sweden)

    Evelyn D Olthof

    Full Text Available Patients on home parenteral nutrition (HPN are at risk for catheter-related complications; mainly infections and occlusions. We have previously shown in HPN patients presenting with catheter sepsis that catheter locking with taurolidine dramatically reduced re-infections when compared with heparin. Our HPN population therefore switched from heparin to taurolidine in 2008. The aim of the present study was to compare long-term effects of this catheter lock strategy on the occurrence of catheter-related bloodstream infections and occlusions in HPN patients.Data of catheter-related complications were retrospectively collected from 212 patients who received HPN between January 2000 and November 2011, comprising 545 and 200 catheters during catheter lock therapy with heparin and taurolidine, respectively. We evaluated catheter-related bloodstream infection and occlusion incidence rates using Poisson-normal regression analysis. Incidence rate ratios were calculated by dividing incidence rates of heparin by those of taurolidine, adjusting for underlying disease, use of anticoagulants or immune suppressives, frequency of HPN/fluid administration, composition of infusion fluids, and duration of HPN/fluid use before catheter creation.Bloodstream infection incidence rates were 1.1/year for heparin and 0.2/year for taurolidine locked catheters. Occlusion incidence rates were 0.2/year for heparin and 0.1/year for taurolidine locked catheters. Adjusted incidence ratios of heparin compared to taurolidine were 5.9 (95% confidence interval, 3.9-8.7 for bloodstream infections and 1.9 (95% confidence interval, 1.1-3.1 for occlusions.Given that no other procedural changes than the catheter lock strategy were implemented during the observation period, these data strongly suggest that taurolidine decreases catheter-related bloodstream infections and occlusions in HPN patients compared with heparin.

  19. Neural Network Prediction of Disruptions Caused by Locked Modes on J-TEXT Tokamak

    International Nuclear Information System (INIS)

    Ding Yonghua; Jin Xuesong; Chen Zhenzhen; Zhuang Ge

    2013-01-01

    Prediction of disruptions caused by locked modes using the Back-Propagation (BP) neural network is completed on J-TEXT tokamak. The network, which is based on the BP neural network, uses Mirnov coils and locked mode coils signals as input data, and outputs a signal including information of prediction of locked mode. The rate of successful prediction of locked modes is more than 90%. For intrinsic locked mode disruptions, the network can give a prewarning signal about 1 ms ahead of the locking-time. For the disruption caused by resonant magnetic perturbation (RMPs) locked modes, the network can give a prewarning signal about 10 ms ahead of the locking-time

  20. On the mechanisms governing the repetition rate of mode-locked semiconductor lasers

    DEFF Research Database (Denmark)

    Mulet, Josep; Mørk, Jesper

    2004-01-01

    We investigate the mechanisms influencing the synchronization locking range of mode-locked lasers. We find that changes in repetition rates can be accomodated through a joint interplay of dispersion and pulse shaping effects....

  1. Mode-locking dynamics in a quantum-dash Fabry-Pérot laser diode for packet based clock recovery applications

    NARCIS (Netherlands)

    Maldonado-Basilio, R.; Parra-Cetina, J.; Latkowski, S.; Landais, P.; Calabretta, N.

    2012-01-01

    We experimentally investigate the locking/unlocking dynamics of a mode-locked QDash laser diode for packet-based clock-recovery applications. Results show 20 ns locking times for the passively and externally synchronized mode-locking mechanisms.

  2. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  3. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  4. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  5. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  6. Mode locking of Yb:GdYAG ceramic lasers with an isotropic cavity

    International Nuclear Information System (INIS)

    Xu, C W; Tang, D Y; Zhu, H Y; Zhang, J

    2013-01-01

    We report on the passive mode locking of a diode pumped Yb:GdYAG ceramic laser with a near isotropic cavity. It is found that the laser could simultaneously mode lock in the two orthogonal principal polarization directions of the cavity, and the mode locked pulses of the two polarizations have identical features and are temporally perfectly synchronized. However, their pulse energy varies out-of-phase periodically, manifesting the antiphase dynamics of mode locked lasers. (letter)

  7. Remote Core Locking: Migrating Critical-Section Execution to Improve the Performance of Multithreaded Applications

    OpenAIRE

    Lozi , Jean-Pierre; David , Florian; Thomas , Gaël; Lawall , Julia; Muller , Gilles

    2014-01-01

    National audience; The scalability of multithreaded applications on current multicore systems is hampered by the performance of lock algorithms, due to the costs of access contention and cache misses. In this paper, we propose a new lock algorithm, Remote Core Locking (RCL), that aims to improve the performance of critical sections in legacy applications on multicore architectures. The idea of RCL is to replace lock acquisitions by optimized remote procedure calls to a dedicated server core. ...

  8. Phase-locked loops. [in analog and digital circuits communication system

    Science.gov (United States)

    Gupta, S. C.

    1975-01-01

    An attempt to systematically outline the work done in the area of phase-locked loops which are now used in modern communication system design is presented. The analog phase-locked loops are well documented in several books but discrete, analog-digital, and digital phase-locked loop work is scattered. Apart from discussing the various analysis, design, and application aspects of phase-locked loops, a number of references are given in the bibliography.

  9. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  10. New fixation method for maxillary distraction osteogenesis using locking attachments.

    Science.gov (United States)

    Suzuki, Eduardo Yugo; Buranastidporn, Boonsiva; Ishii, Masatoshi

    2006-10-01

    The external traction hooks of the intraoral splint used in the rigid external distraction (RED) system for maxillary distraction osteogenesis interfere with the surgical procedures. The purpose of this study is to introduce an innovative splint fixation method for maxillary distraction osteogenesis with Locking Attachments and evaluate their advantages, such as reduction of operating time compared with the traditional intraoral splint method. Retrospective comparison of operative times of maxillary Le Fort I osteotomy procedures was carried out with the traditional protocol using the intraoral splint cemented to the maxillary dentition (n = 14), and a removable intraoral splint that is inserted postsurgically (n = 14). Operative procedure times were compared and analyzed statistically using the data extracted from the surgical records. There were no complications inserting the removable splint postsurgically, including pain, discomfort, or time-consuming procedure. Stable and secure splint fixation was obtained before the distraction procedure and the desired treatment goals were obtained in all patients. The total operative procedure times were significantly reduced in the Locking Attachments group by 24% to 41% (approximately 65 minutes) compared with earlier operations involving the conventional splints (P Maxillary distraction osteogenesis with the Locking Attachments is a highly effective fixation approach to manage severe hypoplastic maxilla, eliminating lip constraints resulting from scarring and allowing for easier, more deliberate and careful dissection. The use of the Locking Attachments is reliable in craniofacial surgery and has proved to be advantageous in the reduction of the operating time and surgical risks.

  11. Stop valve with automatic control and locking for nuclear reactors

    International Nuclear Information System (INIS)

    Chung, D.K.

    1980-01-01

    This invention generally concerns an automatic control and locking stop valve. Specifically it relates to the use of such a valve in a nuclear reactor of the type containing absorber elements supported by a fluid and intended for stopping the reactor in complete safety [fr

  12. Automatic carrier acquisition system for phase-lock-loop receivers

    Science.gov (United States)

    Bunce, R. C.

    1973-01-01

    Programmable oscillator and zero-beat detector acquires phase-lock of carrier by frequency scanning. Generation of high-level dc pulse at instant of zero crossing provides positive trigger for decision gate to stop search and close loop for phase-coherent tracking.

  13. Montgomery Point Lock and Dam, White River, Arkansas

    Science.gov (United States)

    2016-01-01

    the time of this study was James E. Walker, Chief, Navigation Branch, HQUSACE. W. Jeff Lillycrop, CHL, was the ERDC Technical Director for... Fischer , and J. Mewes. 2011. Montgomery Point Lock and Dam HSR model, White River miles 4.0 – 0.0; Hydraulic sediment response model investigation

  14. Chip-Multiprocessor Hardware Locks for Safety-Critical Java

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Puffitsch, Wolfgang; Schoeberl, Martin

    2013-01-01

    and may void a task set's schedulability. In this paper we present a hardware locking mechanism to reduce the synchronization overhead. The solution is implemented for the chip-multiprocessor version of the Java Optimized Processor in the context of safety-critical Java. The implementation is compared...

  15. Comparision of the Expandable Nail with Locked Nail in the ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... [5-7] The axial and rotational stability of locked nails depends .... weight bearing was defined as no or minimal pain .... of the nail is changed to load bearing. In delayed .... fractures. J Bone Joint Surg Br 1988;70:206-10. 4.

  16. Heating (Gapless) Color-Flavor Locked Quark Matter

    DEFF Research Database (Denmark)

    Fukushima, Kenji; Kouvaris, Christoforos; Rajagopal, Krishna

    2005-01-01

    We explore the phase diagram of neutral quark matter at high baryon density as a function of the temperature T and the strange quark mass Ms. At T=0, there is a sharp distinction between the insulating color-flavor locked (CFL) phase, which occurs where Ms^2/mu 0 and Delta_2->0) cross. Because we...

  17. Locking mechanisms in degree-4 vertex origami structures

    Science.gov (United States)

    Fang, Hongbin; Li, Suyi; Xu, Jian; Wang, K. W.

    2016-04-01

    Origami has emerged as a potential tool for the design of mechanical metamaterials and metastructures whose novel properties originate from their crease patterns. Most of the attention in origami engineering has focused on the wellknown Miura-Ori, a folded tessellation that is flat-foldable for folded sheet and stacked blocks. This study advances the state of the art and expands the research field to investigate generic degree-4 vertex (4-vertex) origami, with a focus on facet-binding. In order to understand how facet-binding attributes to the mechanical properties of 4-vertex origami structures, geometries of the 4-vertex origami cells are analyzed and analytically expressed. Through repeating and stacking 4-vertex cells, origami sheets and stacked origami blocks can be constructed. Geometry analyses discover four mechanisms that will lead to the self-locking of 4-vertex origami cells, sheets, and stacked blocks: in-cell facet-binding, inlayer facet-binding, inter-layer facet binding, and in-layer and inter-layer facet-bindings. These mechanisms and the predicted self-locking phenomena are verified through 3D simulations and prototype experiments. Finally, this paper briefly introduces the unusual mechanical properties caused by the locking of 4-vertex origami structures. The research reported in this paper could foster a new breed of self-locking structures with various engineering applications.

  18. Semiconductor Mode-Locked Lasers for Optical Communication Systems

    DEFF Research Database (Denmark)

    Yvind, Kresten

    2003-01-01

    The thesis deals with the design and fabrication of semiconductor mode-locked lasers for use in optical communication systems. The properties of pulse sources and characterization methods are described as well as requirements for application in communication systems. Especially, the importance of...

  19. Material Engineering for Monolithic Semiconductor Mode-Locked Lasers

    DEFF Research Database (Denmark)

    Kulkova, Irina

    This thesis is devoted to the materials engineering for semiconductor monolithic passively mode-locked lasers (MLLs) as a compact energy-efficient source of ultrashort optical pulses. Up to the present day, the achievement of low-noise sub-picosecond pulse generation has remained a challenge...

  20. [Locked-in syndrome in literature, cinema and television].

    Science.gov (United States)

    Collado-Vázquez, Susana; Carrillo, Jesús M

    2012-05-01

    Many diseases have been dealt with in literature, cinema or television, including epilepsy, cancer, mental disorders, movement disorders or infectious diseases. Among the many pathologies that have been considered, locked-in syndrome is one that has been of particular interest to writers and film-makers. To review how locked-in syndrome has been portrayed in literature, cinema and television. Locked-in syndrome is a state that is generally secondary to a brainstem lesion with involvement of the corticobulbar and corticospinal tracts, thereby impeding the patient from producing any kind of motor response. Patients remain conscious, maintain their higher functions and can both see and hear. Yet, they are quadriplegic with paralysis of the lower cranial nerves and cannot move or speak. They only conserve the capacity to move their eyes vertically and their eyelids, which they can use as a way to communicate. This pathology has come to the attention of writers and film and television directors, who have described characters with this syndrome. Likewise, there are also stories told in the first person by patients who have experienced this condition and who have written their story using eye movements as a means to communicate. Literature, cinema and television have shown an interest in locked-in syndrome and have placed special attention on the problems these patients have to communicate with others.

  1. Problems in Locke's Theory of Knowledge | Minimah | AFRREV IJAH ...

    African Journals Online (AJOL)

    As a solution to the epistemological problem of inquiring into what the human mind is capable of knowing, John Locke, founder of British empiricism rejects the rationalist assumption that the human mind does have a privileged access to reality. He is especially critical of the Cartesian notion of innate ideas as an explanation ...

  2. Huang Zongxi's and John Locke's Rhetoric toward Modernity

    Science.gov (United States)

    Wang, Xiaobo

    2012-01-01

    Huang Zongxi was an influential seventeenth century Chinese political and social theorist who is considered by many to be the inspiration and founding father of democracy and human rights in China. This article examines the many similarities in thought and social influence between Huang and his contemporary, the English philosopher John Locke.…

  3. Workshop on gate valve pressure locking and thermal binding

    International Nuclear Information System (INIS)

    Brown, E.J.

    1995-07-01

    The purpose of the Workshop on Gate Valve Pressure Locking and Thermal Binding was to discuss pressure locking and thermal binding issues that could lead to inoperable gate valves in both boiling water and pressurized water reactors. The goal was to foster exchange of information to develop the technical bases to understand the phenomena, identify the components that are susceptible, discuss actual events, discuss the safety significance, and illustrate known corrective actions that can prevent or limit the occurrence of pressure locking or thermal binding. The presentations were structured to cover U.S. Nuclear Regulatory Commission staff evaluation of operating experience and planned regulatory activity; industry discussions of specific events, including foreign experience, and efforts to determine causes and alleviate the affects; and valve vendor experience and recommended corrective action. The discussions indicated that identifying valves susceptible to pressure locking and thermal binding was a complex process involving knowledge of components, systems, and plant operations. The corrective action options are varied and straightforward

  4. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... joint stiffness due to prolonged immobilization.[8,9] Open reduction and internal fixation have reduced some of these complications by enabling early mobilization of the patient after surgery. The gold standard for treating closed femoral shaft fractures currently is closed locked intramedullary nailing.[10-13] ...

  5. Mode locking and spatiotemporal chaos in periodically driven Gunn diodes

    DEFF Research Database (Denmark)

    Mosekilde, Erik; Feldberg, Rasmus; Knudsen, Carsten

    1990-01-01

    oscillation entrains with the external signal. This produces a devil’s staircase of frequency-locked solutions. At higher microwave amplitudes, period doubling and other forms of mode-converting bifurcations can be seen. In this interval the diode also exhibits spatiotemporal chaos. At still higher microwave...

  6. Sampling phase lock loop (PLL) with low power clock buffer

    NARCIS (Netherlands)

    Gao, X.; Bahai, A.; Bohsali, M.; Djabbari, A.; Klumperink, Eric A.M.; Nauta, Bram; Socci, G.

    2013-01-01

    A sampling phase locked loop (PLL) circuit includes a pull-up/down buffer configured to convert an oscillator reference clock into a square wave sampling control signal input to a sampling phase detector. The buffer circuit is configured to reduce power by controlling the switching of the pull-up

  7. Biological activity and biotechnological aspects of locked nucleic acids

    DEFF Research Database (Denmark)

    Lundin, Karin E; Højland, Torben; Hansen, Bo

    2013-01-01

    Locked nucleic acid (LNA) is one of the most promising new nucleic acid analogues that has been produced under the past two decades. In this chapter, we have tried to cover many of the different areas, where this molecule has been used to improve the function of synthetic oligonucleotides (ONs). ...

  8. Development of phase lock loop system for synchronisation of a ...

    African Journals Online (AJOL)

    Phase locked loop (PLL) is an important part of the control unit of the grid connected power converter. The method of zero crossing detection (ZCD) does not produce accurate phase information when grid is non-ideal. In this work, a synchronous reference frame (SRF) PLL method to obtain accurate phase information when ...

  9. More Colleges Lock in Energy Rates to Avoid Volatile Markets

    Science.gov (United States)

    Carlson, Scott

    2009-01-01

    In July, when energy prices were sky-high and some pundits were predicting a continued rise, Charles Riordan, facilities director at Loyola College of Maryland, and his colleagues locked in a chunk of their electricity prices--about a quarter of the college's consumption--to cover the next two years. Now that energy prices have fallen, the…

  10. Shape Memory Alloy (SMA)-Based Launch Lock

    Science.gov (United States)

    Badescu, Mircea; Bao, Xiaoqi; Bar-Cohen, Yoseph

    2014-01-01

    Most NASA missions require the use of a launch lock for securing moving components during the launch or securing the payload before release. A launch lock is a device used to prevent unwanted motion and secure the controlled components. The current launch locks are based on pyrotechnic, electro mechanically or NiTi driven pin pullers and they are mostly one time use mechanisms that are usually bulky and involve a relatively high mass. Generally, the use of piezoelectric actuation provides high precession nanometer accuracy but it relies on friction to generate displacement. During launch, the generated vibrations can release the normal force between the actuator components allowing shaft's free motion which could result in damage to the actuated structures or instruments. This problem is common to other linear actuators that consist of a ball screw mechanism. The authors are exploring the development of a novel launch lock mechanism that is activated by a shape memory alloy (SMA) material ring, a rigid element and an SMA ring holding flexure. The proposed design and analytical model will be described and discussed in this paper.

  11. Het slavernijverleden van John Locke : Naar een minder wit curriculum?

    NARCIS (Netherlands)

    Veraart, W.J.; Van Beers, Britta; Van Domselaar, Iris

    2017-01-01

    In this contribution I critically address the practical and theoretical attitude of the philosopher John Locke towards the trans-Atlantic slave trade and the colonial system of chattel slavery of people of African descent, in connection with the question how we should deal with the colonial context

  12. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Ahmet A Karaarslan

    2016-01-01

    Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.

  13. 75 FR 71548 - Clarification of the Post Office Box Lock Replacement Fee

    Science.gov (United States)

    2010-11-24

    ... POSTAL SERVICE 39 CFR Part 111 Clarification of the Post Office Box Lock Replacement Fee AGENCY... of the lock replacement fee for Post Office TM boxes to reflect current practice. DATES: January 2... Standards for Domestic Mailing Services (75 FR 39477-39492). The applicability of the lock replacement fee...

  14. 49 CFR 236.335 - Dogs, stops and trunnions of mechanical locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Dogs, stops and trunnions of mechanical locking..., AND APPLIANCES Interlocking Rules and Instructions § 236.335 Dogs, stops and trunnions of mechanical locking. Driving pieces, dogs, stops and trunnions shall be rigidly secured to locking bars. Swing dogs...

  15. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock on hand-operated switch; control...

  16. 33 CFR 162.175 - Black Rock Canal and Lock at Buffalo, New York.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Black Rock Canal and Lock at Buffalo, New York. 162.175 Section 162.175 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Black Rock Canal and Lock at Buffalo, New York. In the Black Rock Canal and Lock, no vessel may exceed 6...

  17. 49 CFR 236.16 - Electric lock, main track releasing circuit.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock, main track releasing circuit. 236... Rules and Instructions: All Systems General § 236.16 Electric lock, main track releasing circuit. When an electric lock releasing circuit is provided on the main track to permit a train or an engine to...

  18. 49 CFR 236.308 - Mechanical or electric locking or electric circuits; requisites.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Interlocking Standards § 236.308 Mechanical or electric locking or electric circuits; requisites. Mechanical or electric locking or electric circuits shall be installed to prevent signals from... 49 Transportation 4 2010-10-01 2010-10-01 false Mechanical or electric locking or electric...

  19. The transient evolution of AM mode locking a TEA CO2laser

    NARCIS (Netherlands)

    van Goor, F.A.; Bonnie, Ronald J.M.; Witteman, W.J.

    1985-01-01

    The evolution of the pulse in an AM mode-locked TEA CO2laser has been investigated. The experiments have been performed by injecting the mode-locked pulses in a high-pressure slave oscillator at various time intervals after the initiation of the mode-lock process. This technique allows the

  20. Door locking and exit security measures on acute psychiatric admission wards

    NARCIS (Netherlands)

    Nijman, H.L.I.; Bowers, L.; Haglund, K.; Muir-Cochrane, E.; Simpson, A.; Merwe, M. van der

    2011-01-01

    Locking the exit doors of psychiatric wards is believed to reduce the risk of patients absconding. The aims of the study were to investigate both the prevalence of door locking and other exit security measures on UK admission wards, as well as whether door locking appears to be effective in keeping

  1. Diode array pumped, non-linear mirror Q-switched and mode-locked

    Indian Academy of Sciences (India)

    A non-linear mirror consisting of a lithium triborate crystal and a dichroic output coupler are used to mode-lock (passively) an Nd : YVO4 laser, pumped by a diode laser array. The laser can operate both in cw mode-locked and simultaneously Q-switched and mode-locked (QML) regime. The peak power of the laser while ...

  2. 75 FR 76943 - Regulated Navigation Area; Hudson River South of the Troy Locks, NY

    Science.gov (United States)

    2010-12-10

    ...-AA11 Regulated Navigation Area; Hudson River South of the Troy Locks, NY AGENCY: Coast Guard, DHS... Navigation Area (RNA) on the navigable waters of the Hudson River in New York, south of the Troy Locks. This... within the waters of the Hudson River south of the Troy Locks when ice is a threat to navigation. DATES...

  3. 75 FR 8486 - Regulated Navigation Area; Hudson River south of the Troy Locks, New York

    Science.gov (United States)

    2010-02-25

    ...-AA11 Regulated Navigation Area; Hudson River south of the Troy Locks, New York AGENCY: Coast Guard, DHS... area on the navigable waters of the Hudson River south of the Troy Locks. This regulated navigation... Hudson River south of the Troy locks when ice conditions are 8 inches or greater unless authorized by the...

  4. 76 FR 8654 - Regulated Navigation Area; Hudson River South of the Troy Locks, NY

    Science.gov (United States)

    2011-02-15

    ...-AA11 Regulated Navigation Area; Hudson River South of the Troy Locks, NY AGENCY: Coast Guard, DHS... navigable waters of the Hudson River in New York, south of the Troy Locks. This action is necessary to... Hudson River south of the Troy Locks when ice is a threat to navigation. DATES: This rule is effective in...

  5. Exploring How User Routine Affects the Recognition Performance of a Lock Pattern

    NARCIS (Netherlands)

    de Wide, Lisa; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2015-01-01

    To protect an Android smartphone against attackers, a lock pattern can be used. Nevertheless, shoulder-surfing and smudge attacks can be used to get access despite of this protection. To combat these attacks, biometric recognition can be added to the lock pattern, such that the lock-pattern

  6. 49 CFR 236.340 - Electromechanical interlocking machine; locking between electrical and mechanical levers.

    Science.gov (United States)

    2010-10-01

    ... Electromechanical interlocking machine; locking between electrical and mechanical levers. In electro-mechanical interlocking machine, locking between electric and mechanical levers shall be maintained so that mechanical... 49 Transportation 4 2010-10-01 2010-10-01 false Electromechanical interlocking machine; locking...

  7. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    Science.gov (United States)

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  8. Automatic Locking of Laser Frequency to an Absorption Peak

    Science.gov (United States)

    Koch, Grady J.

    2006-01-01

    An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that

  9. Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

    Science.gov (United States)

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fuerst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection and one because of a comminuted radial fracture 11 days after fixation of the olecranon fracture. Complications encountered after discharge of the horses from the Equine Hospital at the Vetsuisse Faculty (University of Zurich) included implant infection (n=2) and lameness (n=3), which were successfully treated with implant removal. Despite being easier to use, LCP osteosynthesis resulted in a clinical outcome similar to DCP osteosynthesis.

  10. Reusable locking tube in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a reconstitutable fuel assembly including a top nozzle with an adapter plate having an interior wall forming at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having an outer socket formed by a circumferential groove defined in the adapter plate passageway wall and opening into the passageway and an inner socket formed by a circumferential bulge and at least one longitudinal slot defined in the upper end portion of the guide thimble. The circumferential bulge is capable of seating within the circumferential groove, an improved reusable tube for releasably locking the inner socket of the guide thimble upper end portion in locking engagement within the outer socket of the adapter plate passageway when the circumferential bulge is seated within the circumferential groove. The reusable tube comprises: (a) an elongated hollow tubular body capable of insertion within the adapter plate passageway and guide thimble upper end portion to a locking position therein such that the circumferential bulge of the inner socket is maintained seated in the locking engagement with the circumferential groove of the outer socket; and (b) at least a pair of dimples performed on the exterior of the tubular body prior to insertion of the body in the guide thimble upper end portion and to the locking position, the dimples being performed and configured to increase the thickness of the tubular body in relation to the remainder of the tubular body. The dimples are substantially resisting resilient yielding in relation to the remainder of the tubular body

  11. Peak-locking reduction for particle image velocimetry

    International Nuclear Information System (INIS)

    Michaelis, Dirk; Wieneke, Bernhard; Neal, Douglas R

    2016-01-01

    A parametric study of the factors contributing to peak-locking, a known bias error source in particle image velocimetry (PIV), is conducted using synthetic data that are processed with a state-of-the-art PIV algorithm. The investigated parameters include: particle image diameter, image interpolation techniques, the effect of asymmetric versus symmetric window deformation, number of passes and the interrogation window size. Some of these parameters are found to have a profound effect on the magnitude of the peak-locking error. The effects for specific PIV cameras are also studied experimentally using a precision turntable to generate a known rotating velocity field. Image time series recorded using this experiment show a linear range of pixel and sub-pixel shifts ranging from 0 to  ±4 pixels. Deviations in the constant vorticity field (ω z ) reveal how peak-locking can be affected systematically both by varying parameters of the detection system such as the focal distance and f -number, and also by varying the settings of the PIV analysis. A new a priori technique for reducing the bias errors associated with peak-locking in PIV is introduced using an optical diffuser to avoid undersampled particle images during the recording of the raw images. This technique is evaluated against other a priori approaches using experimental data and is shown to perform favorably. Finally, a new a posteriori anti peak-locking filter (APLF) is developed and investigated, which shows promising results for both synthetic data and real measurements for very small particle image sizes. (paper)

  12. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  13. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  14. Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

    Science.gov (United States)

    Singh, Ashutosh Kumar; Narsaria, Nidi; G R, Arun; Srivastava, Vivek

    Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstable trochanteric fractures were randomly assigned (using a sealed envelope method) to treatment with either PFN (24 patients) or PFLCP (24 patients). Perioperative data and complications were recorded. All cases were followed up for 2 years. The groups did not differ significantly (P > .05) in operative time, reduction quality, complications, hospital length of stay, union rate, or time to union. Compared with the PFLCP group, the PFN group had shorter incisions and less blood loss. Regarding functional outcomes, there was no significant difference in mean Harris Hip Score (P = .48) or Palmer and Parker mobility score (P = .58). Both PFN and PFLCP are effective in internal fixation of unstable trochanteric femur fractures.

  15. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  16. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  17. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  18. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  19. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  20. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Obituary: Martha Locke Hazen, 1931-2006

    Science.gov (United States)

    Williams, Thomas R.; Willson, Lee Anne

    2007-12-01

    Longtime Harvard Curator of Astronomical Photographs and AAVSO officer Martha Hazen passed away on 23 December 2006 at Hingham, Massachusetts, after a short illness due to acute myelogenous leukemia. One of four children of Harold Locke and Katherine (neé Salisbury) Hazen, Martha was born in Cambridge, Massachusetts, on 15 July 1931, and raised in the Town of Belmont, near Cambridge, where she lived for most of her life. Her father coined the term "servo-mechanism" while serving as an engineering professor and dean for graduate students at the Massachusetts Institute of Technology. Her mother majored in chemistry at Mount Holyoke College. After receiving an A.B. in astronomy from Mount Holyoke College in 1953, Martha earned a Ph.D. in astronomy in 1958 from the University of Michigan, defending a dissertation on the distribution of intensity in elliptical galaxies in the Virgo cluster. Martha's marriage to William Liller in 1959, and the births of two children, inevitably slowed down her progress in observational astronomy. As a research fellow of the Harvard College Observatory, Martha continued to observe two to three weeks a year in Chile, and to reduce those observations and publish the results for sixteen years. Martha's first publication, at least as far as Astrophysics Data System includes the literature, was with Alice Farnsworth on the 1952 occultations of stars by the Moon, published in the Astronomical Journal (1953). In 1958 she joined L. R. Doherty and D. H. Menzel on a short note about the calculation of line profiles in a stratified atmosphere, her only theory paper. Martha's most cited paper is "The Distribution of Intensity in Elliptical Galaxies of the Virgo Cluster," (ApJ, 132, p.306, 1960). There she acknowledges Allan Sandage for suggesting the problem and providing some of the data. Her second most cited paper is "Photometric histories of QSOs - Two QSOs with large light amplitude," (Liller, M. H. & Liller, W., ApJ (Letters), 199, p. L133-L

  2. Optimum phase noise reduction and repetition rate tuning in quantum-dot mode-locked lasers

    Energy Technology Data Exchange (ETDEWEB)

    Habruseva, T. [CAPPA, Cork Institute of Technology, Cork (Ireland); Tyndall National Institute, Lee Maltings, Cork (Ireland); Aston University, Aston Triangle, B4 7ET Birmingham (United Kingdom); Arsenijević, D.; Kleinert, M.; Bimberg, D. [Institut für Festkörperphysik, Technische Universität Berlin, Berlin (Germany); Huyet, G.; Hegarty, S. P. [CAPPA, Cork Institute of Technology, Cork (Ireland); Tyndall National Institute, Lee Maltings, Cork (Ireland)

    2014-01-13

    Competing approaches exist, which allow control of phase noise and frequency tuning in mode-locked lasers, but no judgement of pros and cons based on a comparative analysis was presented yet. Here, we compare results of hybrid mode-locking, hybrid mode-locking with optical injection seeding, and sideband optical injection seeding performed on the same quantum dot laser under identical bias conditions. We achieved the lowest integrated jitter of 121 fs and a record large radio-frequency (RF) tuning range of 342 MHz with sideband injection seeding of the passively mode-locked laser. The combination of hybrid mode-locking together with optical injection-locking resulted in 240 fs integrated jitter and a RF tuning range of 167 MHz. Using conventional hybrid mode-locking, the integrated jitter and the RF tuning range were 620 fs and 10 MHz, respectively.

  3. Injection-locking of terahertz quantum cascade lasers up to 35GHz using RF amplitude modulation.

    Science.gov (United States)

    Gellie, Pierre; Barbieri, Stefano; Lampin, Jean-François; Filloux, Pascal; Manquest, Christophe; Sirtori, Carlo; Sagnes, Isabelle; Khanna, Suraj P; Linfield, Edmund H; Davies, A Giles; Beere, Harvey; Ritchie, David

    2010-09-27

    We demonstrate that the cavity resonance frequency - the round-trip frequency - of Terahertz quantum cascade lasers can be injection-locked by direct modulation of the bias current using an RF source. Metal-metal and single-plasmon waveguide devices with roundtrip frequencies up to 35GHz have been studied, and show locking ranges above 200MHz. Inside this locking range the laser round-trip frequency is phase-locked, with a phase noise determined by the RF-synthesizer. We find a square-root dependence of the locking range with RF-power in agreement with classical injection-locking theory. These results are discussed in the context of mode-locking operation.

  4. Tool for cutting locking cups from guide tube mounting screws in a nuclear reactor

    International Nuclear Information System (INIS)

    Nee, J.D.; Hahn, J.J.

    1987-01-01

    This patent describes an apparatus for freeing a socket-head screw from a locking cup therefor in a reactor cavity, wherein the locking cup includes a fixed cylindrical side wall encircling the side surface of the screw head and an annular end wall overlying the outer end surface of the screw head. The apparatus consists of: frame means, cylindrical cutter means having a longitudinal axis and having a frustoconical cutting surface with an inner diameter less than the inner diameter of the locking cup side wall and with an outer diameter greater than the outer diameter of the locking cup side wall, and drive means carried by the frame means and coupled to the cutter means for effecting rotation thereof about the axis, the rotating cutter means are operable for severing the locking cup end wall from the locking cup side wall at the junction therebetween when the cutter means is moved against the locking cup substantially coaxially therewith

  5. Optimum phase noise reduction and repetition rate tuning in quantum-dot mode-locked lasers

    International Nuclear Information System (INIS)

    Habruseva, T.; Arsenijević, D.; Kleinert, M.; Bimberg, D.; Huyet, G.; Hegarty, S. P.

    2014-01-01

    Competing approaches exist, which allow control of phase noise and frequency tuning in mode-locked lasers, but no judgement of pros and cons based on a comparative analysis was presented yet. Here, we compare results of hybrid mode-locking, hybrid mode-locking with optical injection seeding, and sideband optical injection seeding performed on the same quantum dot laser under identical bias conditions. We achieved the lowest integrated jitter of 121 fs and a record large radio-frequency (RF) tuning range of 342 MHz with sideband injection seeding of the passively mode-locked laser. The combination of hybrid mode-locking together with optical injection-locking resulted in 240 fs integrated jitter and a RF tuning range of 167 MHz. Using conventional hybrid mode-locking, the integrated jitter and the RF tuning range were 620 fs and 10 MHz, respectively

  6. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  7. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  8. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  9. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  10. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  11. Spikes matter for phase-locked bursting in inhibitory neurons

    Science.gov (United States)

    Jalil, Sajiya; Belykh, Igor; Shilnikov, Andrey

    2012-03-01

    We show that inhibitory networks composed of two endogenously bursting neurons can robustly display several coexistent phase-locked states in addition to stable antiphase and in-phase bursting. This work complements and enhances our recent result [Jalil, Belykh, and Shilnikov, Phys. Rev. EPLEEE81539-375510.1103/PhysRevE.81.045201 81, 045201(R) (2010)] that fast reciprocal inhibition can synchronize bursting neurons due to spike interactions. We reveal the role of spikes in generating multiple phase-locked states and demonstrate that this multistability is generic by analyzing diverse models of bursting networks with various fast inhibitory synapses; the individual cell models include the reduced leech heart interneuron, the Sherman model for pancreatic beta cells, and the Purkinje neuron model.

  12. Improvement of Frequency Locking Algorithm for Atomic Frequency Standards

    Science.gov (United States)

    Park, Young-Ho; Kang, Hoonsoo; Heyong Lee, Soo; Eon Park, Sang; Lee, Jong Koo; Lee, Ho Seong; Kwon, Taeg Yong

    2010-09-01

    The authors describe a novel method of frequency locking algorithm for atomic frequency standards. The new algorithm for locking the microwave frequency to the Ramsey resonance is compared with the old one that had been employed in the cesium atomic beam frequency standards such as NIST-7 and KRISS-1. Numerical simulations for testing the performance of the algorithm show that the new method has a noise filtering performance superior to the old one by a factor of 1.2 for the flicker signal noise and 1.4 for random-walk signal noise. The new algorithm can readily be used to enhance the frequency stability for a digital servo employing the slow square wave frequency modulation.

  13. Dispersion engineering of mode-locked fibre lasers

    Science.gov (United States)

    Woodward, R. I.

    2018-03-01

    Mode-locked fibre lasers are important sources of ultrashort pulses, where stable pulse generation is achieved through a balance of periodic amplitude and phase evolutions. A range of distinct cavity pulse dynamics have been revealed, arising from the interplay between dispersion and nonlinearity in addition to dissipative processes such as filtering. This has led to the discovery of numerous novel operating regimes, offering significantly improved laser performance. In this Topical Review, we summarise the main steady-state pulse dynamics reported to date through cavity dispersion engineering, including average solitons, dispersion-managed solitons, dissipative solitons, giant-chirped pulses and similaritons. Characteristic features and the stabilisation mechanism of each regime are described, supported by numerical modelling, in addition to the typical performance and limitations. Opportunities for further pulse energy scaling are discussed, in addition to considering other recent advances including automated self-tuning cavities and fluoride-fibre-based mid-infrared mode-locked lasers.

  14. Robert Heath Lock and his textbook of genetics, 1906.

    Science.gov (United States)

    Edwards, A W F

    2013-07-01

    Robert Heath Lock (1879-1915), a Cambridge botanist associated with William Bateson and R. C. Punnett, published his book Recent Progress in the Study of Variation, Heredity, and Evolution in 1906. This was a remarkable textbook of genetics for one appearing so early in the Mendelian era. It covered not only Mendelism but evolution, natural selection, biometry, mutation, and cytology. It ran to five editions but was, despite its success, largely forgotten following Lock's early death in 1915. Nevertheless it was the book that inspired H. J. Muller to do genetics and was remembered by A. H. Sturtevant as the source of the earliest suggestion that linkage might be related to the exchange of parts between homologous chromosomes. Here we also put forward evidence that it had a major influence on the statistician and geneticist R. A. Fisher at the time he was a mathematics student at Cambridge.

  15. Phase-locking transition in a chirped superconducting Josephson resonator.

    Science.gov (United States)

    Naaman, O; Aumentado, J; Friedland, L; Wurtele, J S; Siddiqi, I

    2008-09-12

    We observe a sharp threshold for dynamic phase locking in a high-Q transmission line resonator embedded with a Josephson tunnel junction, and driven with a purely ac, chirped microwave signal. When the drive amplitude is below a critical value, which depends on the chirp rate and is sensitive to the junction critical current I0, the resonator is only excited near its linear resonance frequency. For a larger amplitude, the resonator phase locks to the chirped drive and its amplitude grows until a deterministic maximum is reached. Near threshold, the oscillator evolves smoothly in one of two diverging trajectories, providing a way to discriminate small changes in I0 with a nonswitching detector, with potential applications in quantum state measurement.

  16. Color center lasers passively mode locked by quantum wells

    International Nuclear Information System (INIS)

    Islam, M.N.; Soccolich, C.E.; Bar-Joseph, I.; Sauer, N.; Chang, T.Y.; Miller, B.I.

    1989-01-01

    This paper describes how, using multiple quantum well (MQW) saturable absorbers, the authors passively mode locked a NaCl color center laser to produce 275 fs transform-limited, pedestal-free pulses with as high as 3.7 kW peak power. The pulses are tunable from λ = 1.59 to 1.7 μm by choosing MQW's with different bandgaps. They shortened the output pulses from the laser to 25 fs using the technique of soliton compression in a fiber. The steady-state operation of the laser requires the combination of a fast saturable absorber and gain saturation. In addition to the NaCl laser, they passively mode locked a Tl 0 (1):KCl color center laser and produced -- 22 ps pulses. Although the 275 fs pulses from the NaCl laser are Gaussian, when broadened, the pulses acquire an asymmetric spectrum because of carrier-induced refractive index changes

  17. Phase Locking a Clock Oscillator to a Coherent Atomic Ensemble

    Directory of Open Access Journals (Sweden)

    R. Kohlhaas

    2015-04-01

    Full Text Available The sensitivity of an atomic interferometer increases when the phase evolution of its quantum superposition state is measured over a longer interrogation interval. In practice, a limit is set by the measurement process, which returns not the phase but its projection in terms of population difference on two energetic levels. The phase interval over which the relation can be inverted is thus limited to the interval [-π/2,π/2]; going beyond it introduces an ambiguity in the readout, hence a sensitivity loss. Here, we extend the unambiguous interval to probe the phase evolution of an atomic ensemble using coherence-preserving measurements and phase corrections, and demonstrate the phase lock of the clock oscillator to an atomic superposition state. We propose a protocol based on the phase lock to improve atomic clocks limited by local oscillator noise, and foresee the application to other atomic interferometers such as inertial sensors.

  18. John Locke on Inference and Fallacy, A Re-Appraisal

    Directory of Open Access Journals (Sweden)

    Mark Garrett Longaker

    2014-12-01

    Full Text Available John Locke, long associated with the “standard” approach to fallacies and the “logical” approach to valid inference, had both logical and dialectical reasons for favoring certain proofs and denigrating others. While the logical approach to argumentation stands forth in Locke’s philosophical writings (such as the Essay Concerning Human Understanding, a dialectical approach can be found in his contributions to public controversies regarding religion and toleration. Understanding Locke’s dialectical approach to argumentation not only makes his work more relevant to the contemporary discipline of informal logic, but this understanding also prompts a reconsideration of Locke’s rhetorical purpose. He approached argumentation dialectically (and logically because he wanted to appeal to a universal audience of free rational subjects, people not unlike the real historical audience whom Locke addressed: radical Whigs, latitudinarian Anglicans, early-Enlightenment philosophes.

  19. A novel calibration method for phase-locked loops

    DEFF Research Database (Denmark)

    Cassia, Marco; Shah, Peter Jivan; Bruun, Erik

    2005-01-01

    A novel method to calibrate the frequency response of a Phase-Locked Loop is presented. The method requires just an additional digital counter to measure the natural frequency of the PLL; moreover it is capable of estimating the static phase offset. The measured value can be used to tune the PLL ...... response to the desired value. The method is demonstrated mathematically on a typical PLL topology and it is extended to SigmaDelta fractional-N PLLs. A set of simulations performed with two different simulators is used to verify the applicability of the method.......A novel method to calibrate the frequency response of a Phase-Locked Loop is presented. The method requires just an additional digital counter to measure the natural frequency of the PLL; moreover it is capable of estimating the static phase offset. The measured value can be used to tune the PLL...

  20. Symbol lock detection implemented with nonoverlapping integration intervals

    Science.gov (United States)

    Shihabi, Mazen M. (Inventor); Hinedi, Sami M. (Inventor); Shah, Biren N. (Inventor)

    1995-01-01

    A symbol lock detector is introduced for an incoming coherent digital communication signal which utilizes a subcarrier modulated with binary symbol data, d(sub k), and known symbol interval T by integrating binary values of the signal over nonoverlapping first and second intervals selected to be T/2, delaying the first integral an interval T/2, and either summing or multiplying the second integral with the first one that preceded it to form a value X(sub k). That value is then averaged over a number M of symbol intervals to produce a static value Y. A symbol lock decision can then be made when the static value Y exceeds a threshold level delta.

  1. Foundry fabricated photonic integrated circuit optical phase lock loop.

    Science.gov (United States)

    Bałakier, Katarzyna; Fice, Martyn J; Ponnampalam, Lalitha; Graham, Chris S; Wonfor, Adrian; Seeds, Alwyn J; Renaud, Cyril C

    2017-07-24

    This paper describes the first foundry-based InP photonic integrated circuit (PIC) designed to work within a heterodyne optical phase locked loop (OPLL). The PIC and an external electronic circuit were used to phase-lock a single-line semiconductor laser diode to an incoming reference laser, with tuneable frequency offset from 4 GHz to 12 GHz. The PIC contains 33 active and passive components monolithically integrated on a single chip, fully demonstrating the capability of a generic foundry PIC fabrication model. The electronic part of the OPLL consists of commercially available RF components. This semi-packaged system stabilizes the phase and frequency of the integrated laser so that an absolute frequency, high-purity heterodyne signal can be generated when the OPLL is in operation, with phase noise lower than -100 dBc/Hz at 10 kHz offset from the carrier. This is the lowest phase noise level ever demonstrated by monolithically integrated OPLLs.

  2. Phase lock of rapid cycling synchrotron and neutron choppers

    International Nuclear Information System (INIS)

    Praeg, W.; McGhee, D.; Volk, G.

    1981-01-01

    The 500-MeV synchrotron of Argonne's Intense Pulsed Neutron Source operates at 30 Hz. Its beam spill must be locked to neutron choppers with a precision of +- 0.5 μs. A chopper and an accelerator have large and different inertias. This makes synchronization by phase lock to the 60-Hz power line extremely difficult. We solved the phasing problems by running both the Ring Magnet Power Supply (RMPS) of the synchrotron and the chopper motors from a common oscillator that is stable to 1 ppM and by controlling five quantities of the RMPS. The quantities controlled by feedback loops are dc current, injection current, ejection current, resonant frequency, and the phase shift between the synchrotron peak field and the chopper window

  3. Mode-locked solid state lasers using diode laser excitation

    Science.gov (United States)

    Holtom, Gary R [Boston, MA

    2012-03-06

    A mode-locked laser employs a coupled-polarization scheme for efficient longitudinal pumping by reshaped laser diode bars. One or more dielectric polarizers are configured to reflect a pumping wavelength having a first polarization and to reflect a lasing wavelength having a second polarization. An asymmetric cavity provides relatively large beam spot sizes in gain medium to permit efficient coupling to a volume pumped by a laser diode bar. The cavity can include a collimation region with a controlled beam spot size for insertion of a saturable absorber and dispersion components. Beam spot size is selected to provide stable mode locking based on Kerr lensing. Pulse durations of less than 100 fs can be achieved in Yb:KGW.

  4. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  5. Mode locking in overdamped charge-density-wave systems

    International Nuclear Information System (INIS)

    Alstroem, P.; Levinsen, M.T.

    1988-01-01

    We show that the rich mode-locking structure observed in overdamped charge-density-wave (CDW) systems can be understood in terms of a simple model of driven damped 'particles' without inertia in a non-sinusoidal periodic potential. The analysis shows that the nonchaotic system of a driven overdamped CDW without inertia in general has a 'close-to-chaotic' behavior in an appropriate frequency range. Our results also provide a natural basis for studies of spatially extended CDW systems. (orig.)

  6. Investigation of Mechanical Breakdowns Leading to Lock Closures

    Science.gov (United States)

    2017-06-01

    anchorage, anchor bolts, anchor bars, pins, etc. 2 Gate cracks or structural failure 2 Barge accidents 1 Electrical and power control issues 0... structural failure 7 ERDC/CERL TR-17-17 9 Cause Occurrences Barge accidents 5 Electrical and power control issues 1 Gate noise 4 Gate vibrations 4...Engineers Washington, DC 20314-1000 Under Project “ Structural Monitoring System for Lock Structures to Prevent Failure” ERDC/CERL TR-17-17 ii Abstract

  7. Architecture Without Explicit Locks for Logic Simulation on SIMD Machines

    OpenAIRE

    Cockshott, W. Paul; Chimeh, Mozhgan Kabiri

    2016-01-01

    The presentation describes an architecture for logic simulation that takes advantages of the features of multi-core SIMD architectures. It uses neither explicit locks nor queues, using instead oblivious simulation. Data structures are targeted to efficient SIMD and multi-core cache operation. We demonstrate high levels of parallelisation on Xeon Phi and AMD multi-core machines. Performance on a Xeon Phi is comparable to or better than on a 1000 core Blue Gene machine.

  8. Modelling colliding-pulse mode-locked semiconductor lasers

    DEFF Research Database (Denmark)

    Bischoff, Svend

    or to determine the optimum operation conditions. The purpose of this thesis is to elucidate some of the physics of interest in the field of semiconductor laser modelling, semiconductor optics and fiber optics. To be more specific we will investigate: The Colliding-Pulse Mode-Locked (CPM) Quantum Well (QW) laser...... diode; the excitonic semiconductor response for varying material thickness in the case of linear optics; and modulational instability of electromagnetic waves in media with spatially varying non-linearity....

  9. Quantum data locking for high-rate private communication

    OpenAIRE

    Lupo, Cosmo; Lloyd, Seth

    2015-01-01

    We show that, if the accessible information is used as a security quantifier, quantum channels with a certain symmetry can convey private messages at a tremendously high rate, as high as less than one bit below the rate of non-private classical communication. This result is obtained by exploiting the quantum data locking effect. The price to pay to achieve such a high private communication rate is that accessible information security is in general not composable. However, composable security ...

  10. Resonator coupled Josephson junctions; parametric excitations and mutual locking

    DEFF Research Database (Denmark)

    Jensen, H. Dalsgaard; Larsen, A.; Mygind, Jesper

    1991-01-01

    Self-pumped parametric excitations and mutual locking in systems of Josephson tunnel junctions coupled to multimode resonators are reported. For the very large values of the coupling parameter, obtained with small Nb-Al2O3-Nb junctions integrated in superconducting microstrip resonators, the DC I......-V characteristic shows an equidistant series of current steps generated by subharmonic pumping of the fundamental resonator mode. This is confirmed by measurement of frequency and linewidth of the emitted Josephson radiation...

  11. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    OpenAIRE

    Lokesh; Dayanand; Deepak; Hemanth

    2016-01-01

    INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articul...

  12. Hardware locks for a real-time Java chip multiprocessor

    DEFF Research Database (Denmark)

    Strøm, Torur Biskopstø; Puffitsch, Wolfgang; Schoeberl, Martin

    2016-01-01

    A software locking mechanism commonly protects shared resources for multithreaded applications. This mechanism can, especially in chip-multiprocessor systems, result in a large synchronization overhead. For real-time systems in particular, this overhead increases the worst-case execution time....... This improvement can allow a larger number of real-time tasks to be reliably scheduled on a multiprocessor real-time platform....

  13. Blocking Optimality in Distributed Real-Time Locking Protocols

    Directory of Open Access Journals (Sweden)

    Björn Bernhard Brandenburg

    2014-09-01

    Full Text Available Lower and upper bounds on the maximum priority inversion blocking (pi-blocking that is generally unavoidable in distributed multiprocessor real-time locking protocols (where resources may be accessed only from specific synchronization processors are established. Prior work on suspension-based shared-memory multiprocessor locking protocols (which require resources to be accessible from all processors has established asymptotically tight bounds of Ω(m and Ω(n maximum pi-blocking under suspension-oblivious and suspension-aware analysis, respectively, where m denotes the total number of processors and n denotes the number of tasks. In this paper, it is shown that, in the case of distributed semaphore protocols, there exist two different task allocation scenarios that give rise to distinct lower bounds. In the case of co-hosted task allocation, where application tasks may also be assigned to synchronization processors (i.e., processors hosting critical sections, Ω(Φ · n maximum pi-blocking is unavoidable for some tasks under any locking protocol under both suspension-aware and suspension-oblivious schedulability analysis, where Φ denotes the ratio of the maximum response time to the shortest period. In contrast, in the case of disjoint task allocation (i.e., if application tasks may not be assigned to synchronization processors, only Ω(m and Ω(n maximum pi-blocking is fundamentally unavoidable under suspension-oblivious and suspension-aware analysis, respectively, as in the shared-memory case. These bounds are shown to be asymptotically tight with the construction of two new distributed real-time locking protocols that ensure O(m and O(n maximum pi-blocking under suspension-oblivious and suspension-aware analysis, respectively.

  14. Single-ion quantum lock-in amplifier.

    Science.gov (United States)

    Kotler, Shlomi; Akerman, Nitzan; Glickman, Yinnon; Keselman, Anna; Ozeri, Roee

    2011-05-05

    Quantum metrology uses tools from quantum information science to improve measurement signal-to-noise ratios. The challenge is to increase sensitivity while reducing susceptibility to noise, tasks that are often in conflict. Lock-in measurement is a detection scheme designed to overcome this difficulty by spectrally separating signal from noise. Here we report on the implementation of a quantum analogue to the classical lock-in amplifier. All the lock-in operations--modulation, detection and mixing--are performed through the application of non-commuting quantum operators to the electronic spin state of a single, trapped Sr(+) ion. We significantly increase its sensitivity to external fields while extending phase coherence by three orders of magnitude, to more than one second. Using this technique, we measure frequency shifts with a sensitivity of 0.42 Hz Hz(-1/2) (corresponding to a magnetic field measurement sensitivity of 15 pT Hz(-1/2)), obtaining an uncertainty of less than 10 mHz (350 fT) after 3,720 seconds of averaging. These sensitivities are limited by quantum projection noise and improve on other single-spin probe technologies by two orders of magnitude. Our reported sensitivity is sufficient for the measurement of parity non-conservation, as well as the detection of the magnetic field of a single electronic spin one micrometre from an ion detector with nanometre resolution. As a first application, we perform light shift spectroscopy of a narrow optical quadrupole transition. Finally, we emphasize that the quantum lock-in technique is generic and can potentially enhance the sensitivity of any quantum sensor. ©2011 Macmillan Publishers Limited. All rights reserved

  15. Complexation Key to a pH Locked Redox Reaction

    Science.gov (United States)

    Rizvi, Masood Ahmad; Dangat, Yuvraj; Shams, Tahir; Khan, Khaliquz Zaman

    2016-01-01

    An unfavorable pH can block a feasible electron transfer for a pH dependent redox reaction. In this experiment, a series of potentiometric titrations demonstrate the sequential loss in feasibility of iron(II) dichromate redox reaction over a pH range of 0-4. The pH at which this reaction failed to occur was termed as a pH locked reaction. The…

  16. Hydrostatic self-locking bevel differential gear; Hydrostatisch selbstsperrendes Kegelraddifferentialgetriebe

    Energy Technology Data Exchange (ETDEWEB)

    Kalmbach, K.

    2001-07-01

    The product range of the rail vehicle industry comprises the construction of railroad material for long-distance and short-distance transport. This includes, for example, locomotives and cars, subway, light railway and tramway cars as well as rail vehicle equipment. The development of the industry is determined by the demand for transport services and government actions for the extension of railways and procurement of suitable vehicle types. In contrast to road vehicles, differential gears are only used in a negligible percentage of rail vehicles. Primarily in the short-distance rail transport sector, the demand for differential gears is growing due to increased drive power, smaller wheel diameters, lower vehicle mass with higher load capacity, the introduction of low-floor technology as well as the requirement of employing ever more quiet vehicles. In hydrostatic self-locking differential gears, oil is supplied to the gears within the differential gearbox. They only rotate relative to each other when the differential gear performs a compensation movement. In this case, oil is transported in the tooth space to the meshing of the gears, where it is displaced due to the meshing and must drain through tight gaps. The pressure generated by this process acts against the compensation movement of the gear, and the drive torque is transmitted to the wheel that has the higher friction. The achievable locking torque is linearly dependent on the differential speed of the drive wheel. This locking effect is achieved without wear-prone components and works automatically without active external intervention. The design space required corresponds to that of conventional differential gears, as the locking effect is integrated in the existing design. (orig.)

  17. Chirp of monolithic colliding pulse mode-locked diode lasers

    DEFF Research Database (Denmark)

    Hofmann, M.; Bischoff, S.; Franck, Thorkild

    1997-01-01

    Spectrally resolved streak camera measurements of picosecond pulses emitted by hybridly colliding pulse mode-locked (CPM) laser diodes are presented in this letter. Depending on the modulation frequency both blue-chirped (upchirped) and red-chirped (downchirped) pulses can be observed. The two...... different regimes and the transition between them are characterized experimentally and the behavior is explained on the basis of our model for the CPM laser dynamics. (C) 1997 American Institute of Physics....

  18. Semiconductor Ion Implanters

    International Nuclear Information System (INIS)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-01-01

    In 1953 the Raytheon CK722 transistor was priced at $7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at $6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing 'only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around $2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  19. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  1. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  2. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified...

  3. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  4. Closable container with a self-locking lid

    International Nuclear Information System (INIS)

    Paressant, Michel; Faucond, Jean; Tellier, Claude.

    1976-01-01

    This invention concerns a closable container with a self-locking lid. The invention applies in particular in automated installations, for instance for the transport of dangerous substances and notably in the nuclear area for removing radioactive waste. The purpose of the invention is therefore to propose a closable container with a lid that can close and lock automatically on the receptacle whilst allowing for easy unlocking and opening by remote means. Under the invention the container comprises a receptacle and a self-locking lid closing it, the said container being such that the edge of the lid is shut down so as to cover that of the receptacle, these two edges cooperating by means of a hooking ramp and catch fitted respectively to each of them, this gear retracting when moving over the ramp in the lid closing direction and butting against it in the reverse direction. The container has unlocking gear to clear the catch from the ramp to free its passage in the lid opening direction [fr

  5. Self-mode-locked AlGaInP-VECSEL

    Science.gov (United States)

    Bek, R.; Großmann, M.; Kahle, H.; Koch, M.; Rahimi-Iman, A.; Jetter, M.; Michler, P.

    2017-10-01

    We report the mode-locked operation of an AlGaInP-based semiconductor disk laser without a saturable absorber. The active region containing 20 GaInP quantum wells is used in a linear cavity with a curved outcoupling mirror. The gain chip is optically pumped by a 532 nm laser, and mode-locking is achieved by carefully adjusting the pump spot size. For a pump power of 6.8 W, an average output power of up to 30 mW is reached at a laser wavelength of 666 nm. The pulsed emission is characterized using a fast oscilloscope and a spectrum analyzer, demonstrating stable single-pulse operation at a repetition rate of 3.5 GHz. Intensity autocorrelation measurements reveal a FWHM pulse duration of 22 ps with an additional coherence peak on top, indicating noise-like pulses. The frequency spectrum, as well as the Gaussian beam profile and the measured beam propagation factor below 1.1, shows no influence of higher order transverse modes contributing to the mode-locked operation.

  6. Active locking and entanglement in type II optical parametric oscillators

    Science.gov (United States)

    Ruiz-Rivas, Joaquín; de Valcárcel, Germán J.; Navarrete-Benlloch, Carlos

    2018-02-01

    Type II optical parametric oscillators are amongst the highest-quality sources of quantum-correlated light. In particular, when pumped above threshold, such devices generate a pair of bright orthogonally-polarized beams with strong continuous-variable entanglement. However, these sources are of limited practical use, because the entangled beams emerge with different frequencies and a diffusing phase difference. It has been proven that the use of an internal wave-plate coupling the modes with orthogonal polarization is capable of locking the frequencies of the emerging beams to half the pump frequency, as well as reducing the phase-difference diffusion, at the expense of reducing the entanglement levels. In this work we characterize theoretically an alternative locking mechanism: the injection of a laser at half the pump frequency. Apart from being less invasive, this method should allow for an easier real-time experimental control. We show that such an injection is capable of generating the desired phase locking between the emerging beams, while still allowing for large levels of entanglement. Moreover, we find an additional region of the parameter space (at relatively large injections) where a mode with well defined polarization is in a highly amplitude-squeezed state.

  7. Crossed and Locked Quotes in a Multi-Market Simulation.

    Science.gov (United States)

    Todd, Andrew; Beling, Peter; Scherer, William

    2016-01-01

    Financial markets are often fragmented, introducing the possibility that quotes in identical securities may become crossed or locked. There are a number of theoretical explanations for the existence of crossed and locked quotes, including competition, simultaneous actions, inattentiveness, fee structure and market access. In this paper, we perform a simulation experiment designed to examine the effect of simple order routing procedures on the properties of a fragmented market consisting of a single security trading in two independent limit order books. The quotes in the two markets are connected solely by the routing decision of the market participants. We report on the health of the consolidated market as measured by the duration of crossed and locked states, as well as the spread and the volatility of transaction prices in the consolidated market. We aim to quantify exactly how the prevalence of order routing among a population of market participants affects properties of the consolidated market. Our model contributes to the zero-intelligence literature by treating order routing as an experimental variable. Additionally, we introduce a parsimonious heuristic for limit order routing, allowing us to study the effects of both market order routing and limit order routing. Our model refines intuition for the sometimes subtle relationships between the prevalence of order routing and various market measures. Our model also provides a benchmark for more complex agent-based models.

  8. True Low-Power Self-Locking Soft Actuators.

    Science.gov (United States)

    Kim, Seung Jae; Kim, Onnuri; Park, Moon Jeong

    2018-03-01

    Natural double-layered structures observed in living organisms are known to exhibit asymmetric volume changes with environmental triggers. Typical examples are natural roots of plants, which show unique self-organized bending behavior in response to environmental stimuli. Herein, light- and electro-active polymer (LEAP) based actuators with a double-layered structure are reported. The LEAP actuators exhibit an improvement of 250% in displacement and hold an object three times heavier as compared to that in the case of conventional electro-active polymer actuators. Most interestingly, the bending motion of the LEAP actuators can be effectively locked for a few tens of minutes even in the absence of a power supply. Further, the self-locking LEAP actuators show a large and reversible bending strain of more than 2.0% and require only 6.2 mW h cm -2 of energy to hold an object for 15 min at an operating voltage of 3 V. These novel self-locking soft actuators should find wide applicability in artificial muscles, biomedical microdevices, and various innovative soft robot technologies. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Silent Aortic Dissection Presenting as Transient Locked-In Syndrome

    Science.gov (United States)

    Nadour, Wadih; Goldwasser, Brian; Biederman, Robert W.; Taffe, Kevin

    2008-01-01

    Acute aortic dissection is a medical emergency. Without prompt recognition and treatment, the mortality rate is high. An atypical presentation makes timely diagnosis difficult, especially if the patient is experiencing no characteristic pain. Many patients with aortic dissection are reported to have presented with various neurologic manifestations, but none with only a presentation of transient locked-in syndrome. Herein, we report a case of completely painless aortic dissection in a woman who presented with a transient episode of anarthria, quadriplegia, and preserved consciousness. On physical examination, she had a 40-point difference in blood pressure between her left and right arms, and a loud diastolic murmur. The diagnosis of acute aortic dissection was reached via a combination of radiography, computed tomography, echocardiography, and a high index of clinical suspicion. The patient underwent emergency surgery and ultimately experienced a successful outcome. To our knowledge, this is the 1st report of aortic dissection that presented solely as locked-in syndrome. We suggest that silent aortic dissection be added to the differential diagnosis for transient locked-in syndrome. PMID:18941610

  10. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  11. Narrow Q-switching pulse width and low mode-locking repetition rate Q-switched mode locking with a new coupled laser cavity

    International Nuclear Information System (INIS)

    Peng, J Y; Zheng, Y; Shen, J P; Shi, Y X

    2013-01-01

    An original diode-pumped Q-switched and mode-locked solid state Nd:GdVO 4 laser is demonstrated. The laser operates with double saturable absorbers and a new coupled laser cavity. The Q-switching envelope width is compressed to be about 15 ns and the mode-locking repetition rate is as low as 90 MHz. (paper)

  12. CONSTRUCTION SELF-PROPELLED PNEUMOPUNCHERS WITH LOCKING MECHANISM

    Directory of Open Access Journals (Sweden)

    V. K. Perederey

    2016-01-01

    Full Text Available The paper reveals one of possible methods for higher productivity and reliability of building self-propelled pneumopunchers which are intended for making holes in soil while using trenchless method and constructing various engineering communications under car, tram and rail lines, airport runways. A new design of building pneumopuncher with increased productivity due to higher speed for hole formation in soil and its reliability has been presented in the paper. A formula for determination of displacement increment for a new pneumopuncher in comparison with the conventional one has been obtained in the paper. The paper describes a design and operation principal of the building self-propelled pneumopuncher which is equipped with a locking mechanism with the purpose to neutralize action of soil elastic forces and reactive repulsive force. The locking mechanism keeps the pneumopuncher in the hole. The pneumopuncher consists of a body with anvil, movable hammer, a manifold which is set in axial deepening of the hammer, a nut and a locking mechanism. Improvement of operational pneumopuncher reliability is attained due to the fact that the locking mechanism is made in the form of two coaxially positioned inner and outer cups having a common basis. A piston is installed in the middle of the inner cup, a spring is fixed over the piston and a rod with a breaking shoe is positioned at the end. Height of the inner cup is less the outer cup height and there is an annular cavity between them which is connected with a chamber. The chamber is formed by the piston, the inner cup and the manifold. The annular cavity through an opening in the inner cup wall, two sylphons, a channel in the nut end and an opening in the vertical wall of the manifold are connected with a chamber of operating stroke. The sylphons are placed between the outer cup and the nut, between the nut and the manifold. Differential equations for movement of pneumopuncher in soil have been

  13. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  14. A Digital Phase Lock Loop for an External Cavity Diode Laser

    International Nuclear Information System (INIS)

    Wang Xiao-Long; Tao Tian-Jiong; Cheng Bing; Wu Bin; Xu Yun-Fei; Wang Zhao-Ying; Lin Qiang

    2011-01-01

    A digital optical phase lock loop (OPLL) is implemented to synchronize the frequency and phase between two external cavity diode lasers (ECDL), generating Raman pulses for atom interferometry. The setup involves all-digital phase detection and a programmable digital proportional-integral-derivative (PID) loop in locking. The lock generates a narrow beat-note linewidth below 1 Hz and low phase-noise of 0.03rad 2 between the master and slave ECDLs. The lock proves to be stable and robust, and all the locking parameters can be set and optimized on a computer interface with convenience, making the lock adaptable to various setups of laser systems. (fundamental areas of phenomenology(including applications))

  15. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  16. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... of radiation therapy was associated with a non-significantly increased risk of reoperation after both 1-stage (HR = 1.4; 95% CI: 0.7-2.5) and 2-stage (HR = 1.6; 95% CI: 0.9-3.1) procedures. Reconstruction failure was highest (13.2%) in the 2-stage procedures with a history of radiation therapy. Breast...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  17. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  18. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  19. Nonlinear effects in defect production by atomic and molecular ion implantation

    International Nuclear Information System (INIS)

    David, C.; Dholakia, Manan; Chandra, Sharat; Nair, K. G. M.; Panigrahi, B. K.; Amirthapandian, S.; Amarendra, G.; Varghese Anto, C.; Santhana Raman, P.; Kennedy, John

    2015-01-01

    This report deals with studies concerning vacancy related defects created in silicon due to implantation of 200 keV per atom aluminium and its molecular ions up to a plurality of 4. The depth profiles of vacancy defects in samples in their as implanted condition are carried out by Doppler broadening spectroscopy using low energy positron beams. In contrast to studies in the literature reporting a progressive increase in damage with plurality, implantation of aluminium atomic and molecular ions up to Al 3 , resulted in production of similar concentration of vacancy defects. However, a drastic increase in vacancy defects is observed due to Al 4 implantation. The observed behavioural trend with respect to plurality has even translated to the number of vacancies locked in vacancy clusters, as determined through gold labelling experiments. The impact of aluminium atomic and molecular ions simulated using MD showed a monotonic increase in production of vacancy defects for cluster sizes up to 4. The trend in damage production with plurality has been explained on the basis of a defect evolution scheme in which for medium defect concentrations, there is a saturation of the as-implanted damage and an increase for higher defect concentrations

  20. The breast implant controversy.

    Science.gov (United States)

    Cook, R R; Harrison, M C; LeVier, R R

    1994-02-01

    The breast implant issue is a "bad news/good news" story. For many women with implants, the controversy has caused a fair degree of anxiety which may or may not be resolved as further information becomes available. It has also taken its toll on Dow Corning. Whole lines of medical products have been eliminated or are being phase out. The development of new medical applications has been terminated. As a consequence, employees have lost their jobs. What the effect will be on the biomedical industry as a whole remains to be seen (11). While silicones have been an important component in various medical devices, it is likely that other materials can be used as replacements. However, suppliers of non-silicone materials are also reevaluating their role in this market. For example, Du Pont, the nation's largest chemical company, has determined that the unpredictable and excessive costs of doing business with manufacturers of implantable medical devices no longer justifies the unrestricted sale of standard raw materials into this industry. Other companies are quietly following suit. On the up side, it is possible that the research being driven by this controversy will result in a greater understanding of the immunologic implications of xenobiotics, of the importance of nonbiased observations, of the need for ready access to valid data sets, and of the opportunity for valid scientific information to guide legal decisions. Only time will tell.

  1. Technology Corner: Calculating the Number of Android Lock Patterns: An Unfinished Study in Number Theory

    Directory of Open Access Journals (Sweden)

    Gary Kessler

    2013-12-01

    Full Text Available Although one is unlikely to ever want to brute-force an Android lock pattern, many do wonder about the relative strength of the lock pattern versus a multi-digit personal identification number (PIN. It becomes obvious pretty quickly that there are many more lock patterns than the 10,000 possible four-digit PINs.(see PDF for full technology corner

  2. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    Science.gov (United States)

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  3. An Herculean Mind: il problematico ruolo di Locke come precursore dell’utilitarismo

    OpenAIRE

    Russo, Raffaele

    2016-01-01

    There are, apparently, many differences between the ethical theory of Locke and the next utilitarianism of Bentham, so much so that the explicit appreciations, that the same Bentham expressed about Locke in many occasions, seem surprising.This paper examines some of the most striking differences between the two philosophies, and it does not find in the moral philosophy of Locke elements that are incompatible with utilitarianism widely understood, so that one can see in Locke’s hedonistic empi...

  4. Review of Ice-Control Methods at Lock 8, Welland Canal, Port Colborne, Ontario

    Science.gov (United States)

    2016-05-01

    passes through the first air curtain (i.e., by live video camera mounted near the bullnose with a monitor at the lock house) and activate the second...methods, including an air curtain to hold ice above the lock, bubblers and mechanical means to reduce the ice accumulation on the lock walls, and...modifications include reducing the air - curtain and bubblers nozzle size to make the flow across the manifolds more uniform. The only system that the St

  5. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  6. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  7. A New Key-lock Method for User Authentication and Access Control

    Institute of Scientific and Technical Information of China (English)

    JI Dongyao; ZHANG Futai; WANG Yumin

    2001-01-01

    We propose a new key-lock methodfor user authentication and access control based onChinese remainder theorem, the concepts of the ac-cess control matrix, key-lock-pair, time stamp, and the NS public key protocol. Our method is dynamicand needs a minimum amount of computation in thesense that it only updates at most one key/lock foreach access request. We also demonstrate how an au-thentication protocol can be integrated into the ac-cess control method. By applying a time stamp, themethod can not only withstand replay attack, butalso strengthen the authenticating mechanism, whichcould not be achieved simultaneously in previous key-lock methods.

  8. Control of integrated micro-resonator wavelength via balanced homodyne locking.

    Science.gov (United States)

    Cox, Jonathan A; Lentine, Anthony L; Trotter, Douglas C; Starbuck, Andrew L

    2014-05-05

    We describe and experimentally demonstrate a method for active control of resonant modulators and filters in an integrated photonics platform. Variations in resonance frequency due to manufacturing processes and thermal fluctuations are corrected by way of balanced homodyne locking. The method is compact, insensitive to intensity fluctuations, minimally disturbs the micro-resonator, and does not require an arbitrary reference to lock. We demonstrate long-term stable locking of an integrated filter to a laser swept over 1.25 THz. In addition, we show locking of a modulator with low bit error rate while the chip temperature is varied from 5 to 60° C.

  9. Modeling of mode-locked coupled-resonator optical waveguide lasers

    DEFF Research Database (Denmark)

    Agger, Christian; Skovgård, Troels Suhr; Gregersen, Niels

    2010-01-01

    Coupled-resonator optical waveguides made from coupled high-Q photonic crystal nanocavities are investigated for use as cavities in mode-locked lasers. Such devices show great potential in slowing down light and can serve to reduce the cavity length of a mode-locked laser. An explicit expression...... of the emerging pulse train. A range of tuning around this frequency allows for effective mode locking. Finally, noise is added to the generalized single-cavity eigenfrequencies in order to evaluate the effects of fabrication imperfections on the cold-cavity transmission properties and consequently on the locking...

  10. Phase-locking of driven vortex lattices with transverse ac force and periodic pinning

    International Nuclear Information System (INIS)

    Reichhardt, Charles; Kolton, Alejandro B.; Dominguez, Daniel; Gronbech-Jensen, Niels

    2001-01-01

    For a vortex lattice moving in a periodic array we show analytically and numerically that a new type of phase locking occurs in the presence of a longitudinal dc driving force and a transverse ac driving force. This phase locking is distinct from the Shapiro step phase locking found with longitudinal ac drives. We show that an increase in critical current and a fundamental phase-locked step width scale with the square of the driving ac amplitude. Our results should carry over to other systems such as vortex motion in Josephson-junction arrays

  11. Locking a molecular bond: A case study of CsI

    DEFF Research Database (Denmark)

    Szakács, Tamás; Amstrup, Bjarne; Gross, Peter

    1994-01-01

    This paper treats the problem of locking a molecular bond at a length other than the equilibrium distance, with the help of optical electric fields. Locking conditions for single-color fields are examined, and slowly decaying locked wave functions are sought. These were functions are then used...... as target functions in an optimal control procedure. The resultant solution is an optimal field that creates a wave function as close as possible to the target function, followed by the application of a locking single-color field that can keep a large part of this wave function at the given position...

  12. Properties of InGaAs quantum dot saturable absorbers in monolithic mode-locked lasers

    DEFF Research Database (Denmark)

    Thompson, M.G.; Marinelli, C.; Chu, Y.

    Saturable absorbers properties are characterised in monolithic mode-locked InGaAs quantum dot lasers. We analyse the impact of weak quantum confined Stark effect, fast absorber recovery time and low absorber saturation power on the mode-locking performance.......Saturable absorbers properties are characterised in monolithic mode-locked InGaAs quantum dot lasers. We analyse the impact of weak quantum confined Stark effect, fast absorber recovery time and low absorber saturation power on the mode-locking performance....

  13. The locking and unlocking thresholds for tearing modes in a cylindrical tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Wenlong [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Zhu, Ping, E-mail: pzhu@ustc.edu.cn [CAS Key Laboratory of Geospace Environment and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2016-03-15

    The locking and unlocking thresholds for tearing modes are in general different. In this work, the physics origin for this difference is illustrated from theory analysis, and a numerical procedure is developed to find both locking and unlocking thresholds. In particular, a new scaling law for the unlocking threshold that is valid in both weak and strong rotation regimes has been derived from the lowest amplitude of the RMP (resonant magnetic perturbation) allowed for the locked-mode solution. Above the unlocking threshold, the criterion for the phase-flip instability is extended to identify the entire locked-mode states. Two different regimes of the RMP amplitude in terms of the accessibility of the locked-mode states have been found. In the first regime, the locked-mode state may or may not be accessible depending on the initial conditions of an evolving island. In the second regime, the locked-mode state can always be reached regardless of the initial conditions of the tearing mode. The lowest RMP amplitude for the second regime is determined to be the mode-locking threshold. The different characteristics of the two regimes above the unlocking threshold reveal the underlying physics for the gap between the locking and unlocking thresholds and provide an explanation for the closely related and widely observed hysteresis phenomena in island evolution during the sweeping process of the RMP amplitude up and down across that threshold gap.

  14. Reusable locking tube insertion and removal fixture and method in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a locking tube insertion and removal fixture for use with a reconstitutable fuel assembly. The process includes a top nozzle with an adapter plate having at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having a hollow locking tube insertable and removable into and from a locking position in the upper end portion of the guide thimble for releasably locking the upper end portion of the guide thimble within the passageway of the top nozzle and adapter plate

  15. Research on Pin Tumbler Locks and the Characteristics of Surface Traces Formed by Unlocking Guns

    Science.gov (United States)

    Yi, Gao; Yifeng, Jin; Yanping, Bai; Hongcheng, Mei; Zhen, Xu

    2018-02-01

    In this paper, taking the structure of the pin tumbler locks and the principle of opening and closing locks as breakthrough point, we have studied the machining traces of pin tumbler components and trace characters of pin surface during normal operating. At the same time, taking the unlocking gun as an example, the paper analyzes the unlocking technology and the formation of traces, and summarizes the changing rules of the surface traces of elastic bead locks by comparing the positions and the characteristics of the traces, which provides technical support for the future study of traces of pin tumbler locks.

  16. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  17. Genomic and Functional Characterization of the Unusual pLOCK 0919 Plasmid Harboring the spaCBA Pili Cluster in Lactobacillus casei LOCK 0919

    Science.gov (United States)

    Aleksandrzak-Piekarczyk, Tamara; Koryszewska-Bagińska, Anna; Grynberg, Marcin; Nowak, Adriana; Cukrowska, Bożena; Kozakova, Hana; Bardowski, Jacek

    2016-01-01

    Here, we report the extensive bioinformatic and functional analyses of the unusual pLOCK 0919, a plasmid originating from the probiotic Lactobacillus casei LOCK 0919 strain. This plasmid is atypical because it harbors the spaCBA-srtC gene cluster encoding SpaCBA pili. We show that all other spaCBA-srtC sequences of the Lactobacillus genus that have been previously described and deposited in GenBank are present in the chromosomal DNA. Another important observation for pLOCK 0919 is that the spaCBA-srtC gene cluster and its surrounding genes are highly similar to the respective DNA region that is present in the most well-known and active SpaCBA pili producer, the probiotic Lactobacillus rhamnosus GG strain. Our results demonstrate that the spaCBA-srtC clusters of pLOCK 0919 and L. rhamnosus GG are genealogically similar, located in DNA regions that are rich in transposase genes and are poorly conserved among the publicly available sequences of Lactobacillus sp. In contrast to chromosomally localized pilus gene clusters from L. casei and Lactobacillus paracasei, the plasmidic spaC of L. casei LOCK 0919 is expressed and undergoes a slight glucose-induced repression. Moreover, results of series of in vitro tests demonstrate that L. casei LOCK 0919 has an adhesion potential, which is largely determined by the presence of the pLOCK 0919 plasmid. In particular, the plasmid occurrence positively influenced the hydrophobicity and aggregation abilities of L. casei LOCK 0919. Moreover, in vivo studies indicate that among the three Lactobacillus strains used to colonize the gastrointestinal tract of germ-free mice, already after 2 days of colonization, L. casei LOCK 0919 became the dominant strain and persisted there for at least 48 days. PMID:26637469

  18. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  19. Bouncy knee in a semi-automatic knee lock prosthesis.

    Science.gov (United States)

    Fisher, L D; Lord, M

    1986-04-01

    The Bouncy Knee concept has previously proved of value when fitted to stabilised knee units of active amputees. The stance phase flex-extend action afforded by a Bouncy Knee increased the symmetry of gait and also gave better tolerance to slopes and uneven ground. A bouncy function has now been incorporated into a knee of the semi-automatic knee lock design in a pilot laboratory trial involving six patients. These less active patients did not show consistent changes in symmetry of gait, but demonstrated an improved ability to walk on slopes and increased their walking range. Subjective response was positive, as noted in the previous trials.

  20. Quiet planting in the locked constraints satisfaction problems

    Energy Technology Data Exchange (ETDEWEB)

    Zdeborova, Lenka [Los Alamos National Laboratory; Krzakala, Florent [Los Alamos National Laboratory

    2009-01-01

    We study the planted ensemble of locked constraint satisfaction problems. We describe the connection between the random and planted ensembles. The use of the cavity method is combined with arguments from reconstruction on trees and first and second moment considerations; in particular the connection with the reconstruction on trees appears to be crucial. Our main result is the location of the hard region in the planted ensemble, thus providing hard satisfiable benchmarks. In a part of that hard region instances have with high probability a single satisfying assignment.

  1. Phase and Frequency Locked Magnetrons for SRF Sources

    International Nuclear Information System (INIS)

    Neubauer, M.; Johnson, R.P.; Popovic, M.; Moretti, A.

    2009-01-01

    Magnetrons are low-cost highly-efficient microwave sources, but they have several limitations, primarily centered about the phase and frequency stability of their output. When the stability requirements are low, such as for medical accelerators or kitchen ovens, magnetrons are the very efficient power source of choice. But for high energy accelerators, because of the need for frequency and phase stability - proton accelerators need 1-2 degrees source phase stability, and electron accelerators need .1-.2 degrees of phase stability - they have rarely been used. We describe a novel variable frequency cavity technique which will be utilized to phase and frequency lock magnetrons.

  2. Quantum data locking for high-rate private communication

    International Nuclear Information System (INIS)

    Lupo, Cosmo; Lloyd, Seth

    2015-01-01

    We show that, if the accessible information is used as a security quantifier, quantum channels with a certain symmetry can convey private messages at a tremendously high rate, as high as less than one bit below the rate of non-private classical communication. This result is obtained by exploiting the quantum data locking effect. The price to pay to achieve such a high private communication rate is that accessible information security is in general not composable. However, composable security holds against an eavesdropper who is forced to measure her share of the quantum system within a finite time after she gets it. (paper)

  3. Thermal diffusivity measurement by lock-in photothermal shadowgraph method

    Energy Technology Data Exchange (ETDEWEB)

    Cifuentes, A. [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, Ciudad de México 11500 (Mexico); Departamento de Física Aplicada I, Escuela Técnica Superior de Ingeniería, Universidad del País Vasco UPV/EHU, Alameda Urquijo s/n, 48013 Bilbao (Spain); Alvarado, S. [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, Ciudad de México 11500 (Mexico); Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200D, Heverlee B-3001 (Belgium); Cabrera, H. [Centro Multidisciplinario de Ciencias, Instituto Venezolano de Investigaciones Científicas, IVIC, Mérida 5101, Venezuela and SPIE-ICTP Anchor Research in Optics Program Lab, International Centre for Theoretical Physics (ICTP), Strada Costiera 11, Trieste (Italy); Calderón, A.; Marín, E., E-mail: emarinm@ipn.mx [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, Ciudad de México 11500 (Mexico)

    2016-04-28

    Here, we present a novel application of the shadowgraph technique for obtaining the thermal diffusivity of an opaque solid sample, inspired by the orthogonal skimming photothermal beam deflection technique. This new variant utilizes the shadow projected by the sample when put against a collimated light source. The sample is then heated periodically by another light beam, giving rise to thermal waves, which propagate across it and through its surroundings. Changes in the refractive index of the surrounding media due to the heating distort the shadow. This phenomenon is recorded and lock-in amplified in order to determine the sample's thermal diffusivity.

  4. A Quasi-Type-1 Phase-Locked Loop Structure

    DEFF Research Database (Denmark)

    Golestan, Saeed; Fernandez, Francisco Daniel Freijedo; Vidal, Ana

    2014-01-01

    The grid voltage phase and frequency are crucial information in control of most grid connected power electronic based equipment. Most often, a phase-locked loop (PLL) is employed for this purpose. A PLL is a closed-loop feedback control system that the phase of its output signal is related...... to the phase of its input signal. Arguably, the simplest PLL is a type-1 PLL. The type-1 PLLs are characterized by having only one integrator in their control loop and therefore having a high stability margin. However, they suffer from a serious drawback: they cannot achieve zero average steady-state phase...

  5. Brake lock mechanism for the two axis pointing system

    Science.gov (United States)

    Posey, Alan; Clark, Mike; Mignosa, Larry

    1991-01-01

    Six months prior to shipment of the Broadband X-ray Telescope to the Kennedy Space Center for flight aboard the Space Shuttle Columbia, a major system failure occurred. During modal survey testing of the telescope's gimbal pointing system, the roll axis brake unexpectedly released. Low level vibration and static preloads present during the modal survey were within the expected flight environment. Brake release during shuttle liftoff or ascent was an unacceptable risk to mission success; thus, a Brake Lock Mechanism (BLM) was developed.

  6. Class-A mode-locked lasers: Fundamental solutions

    Science.gov (United States)

    Kovalev, Anton V.; Viktorov, Evgeny A.

    2017-11-01

    We consider a delay differential equation (DDE) model for mode-locked operation in class-A semiconductor lasers containing both gain and absorber sections. The material processes are adiabatically eliminated as these are considered fast in comparison to the delay time for a long cavity device. We determine the steady states and analyze their bifurcations using DDE-BIFTOOL [Engelborghs et al., ACM Trans. Math. Software 28, 1 (2002)]. Multiple forms of coexistence, transformation, and hysteretic behavior of stable steady states and fundamental periodic regimes are discussed in bifurcation diagrams.

  7. A lock circuit for a multi-core processor

    DEFF Research Database (Denmark)

    2015-01-01

    An integrated circuit comprising a multiple processor cores and a lock circuit that comprises a queue register with respective bits set or reset via respective, connections dedicated to respective processor cores, whereby the queue register identifies those among the multiple processor cores...... that are enqueued in the queue register. Furthermore, the integrated circuit comprises a current register and a selector circuit configured to select a processor core and identify that processor core by a value in the current register. A selected processor core is a prioritized processor core among the cores...... configured with an integrated circuit; and a silicon die configured with an integrated circuit....

  8. Locke and Leibniz on the Balance of Reasons

    OpenAIRE

    Roinila, Markku

    2013-01-01

    One of the features of John Locke’s moral philosophy is the idea that morality is based on our beliefs concerning the future good. In An Essay Concerning Human Understanding II, xxi, §70, Locke argues that we have to decide between the probability of afterlife and our present temptations. In itself, this kind of decision model is not rare in Early Modern philosophy. Blaise Pascal’s Wager is a famous example of a similar idea of balancing between available options which Marcelo Dascal has disc...

  9. Epidural electrocorticography for monitoring of arousal in locked-in state

    Directory of Open Access Journals (Sweden)

    Alireza eGharabaghi

    2014-10-01

    Full Text Available Electroencephalography often fails to assess both the level (i.e. arousal and the content (i.e. awareness of pathologically altered consciousness in patients without motor responsiveness. This might be related to a decline of awareness, to episodes of low arousal and disturbed sleep patterns, and/or to distorting and attenuating effects of the skull and intermediate tissue on the recorded brain signals. Novel approaches are required to overcome these limitations.We introduced epidural electrocorticography (ECoG for monitoring of cortical physiology in a late-stage amytrophic lateral sclerosis patient in completely locked-in state. Despite long-term application for a period of six months, no implant-related complications occurred. Recordings from the left frontal cortex were sufficient to identify three arousal states. Spectral analysis of the intrinsic oscillatory activity enabled us to extract state-dependent dominant frequencies at < 4, ~ 7 and ~ 20 Hz, representing sleep-like periods, and phases of low and elevated arousal, respectively. In the absence of other biomarkers, ECoG proved to be a reliable tool for monitoring circadian rhythmicity, i.e. avoiding interference with the patient when he was sleeping and exploiting time windows of responsiveness. Moreover, the effects of interventions addressing the patient’s arousal, e.g. amantadine medication, could be evaluated objectively on the basis of physiological markers, even in the absence of behavioral parameters.Epidural ECoG constitutes a feasible trade-off between surgical risk and quality of recorded brain signals to gain information on the patient’s present level of arousal. This approach enables us to optimize the timing of interactions and medical interventions, all of which should take place when the patient is in a phase of high arousal. Furthermore, avoiding low-responsiveness periods will facilitate measures to implement alternative communication pathways involving brain

  10. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  11. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  12. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  13. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  14. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  15. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  16. Determination of water-lock critical value of low-permeability sandstones based on digital core

    Directory of Open Access Journals (Sweden)

    Honglin Zhu

    2016-05-01

    Full Text Available Research and development of water lock inhibiting measures is very crucial in verifying the link mechanism between the internal factors of water lock and its extent of damage. Based on conventional water-lock physics experiments, however, only the consequence of macro water lock damage can be investigated, while the microscopic mechanism cannot be studied. In this paper, 3D digital cores of low-permeability sandstones were prepared by means of high-resolution micro-CT scan, and their equivalent pore network model was built as well. Virtual “imbibition” experiments controlled by capillary force were carried out by using pore-scale flow simulation. Then the link mechanism between the microscopic internal factors (e.g. wettability, water saturation and pore–throat structure parameters and the water-lock damage degree was discussed. It is shown that the damage degree of water lock reduces gradually as the wettability transits from water wet to gas wet. Therefore, the water lock damage can be reduced effectively and gas-well productivity can be improved so long as the capillary environment is changed from strong water wettability to weak gas wettability. The more different the initial water saturation is from the irreducible water saturation, the more serious the water lock damage is. The damage degree of water lock is in a negative correlation with the coordinate number, but a positive correlation with the pore–throat ratio. Based on the existing research results, water lock tends to form in the formations composed of medium-sized throats. It is concluded that there is a critical throat radius, at which the water lock is the most serious.

  17. Adverse effects associated with ethanol catheter lock solutions: a systematic review.

    Science.gov (United States)

    Mermel, Leonard A; Alang, Neha

    2014-10-01

    Antimicrobial lock therapy has been widely utilized internationally for the prevention and management of intravascular catheter-related bloodstream infections. One of the agents commonly utilized for lock therapy is ethanol. However, a systematic review of adverse events associated with ethanol locks has not been published. PubMed was searched to collect articles published from May 2003 through March 2014. The bibliographies of relevant articles were also reviewed. In vitro studies of the mechanical properties of catheters after ethanol immersion have revealed changes predominantly in polyurethane catheters and to a lesser extent in silicone and Carbothane catheters. An elution of polymers from polyurethane and Carbothane catheters has been observed at the ethanol concentrations used in ethanol lock therapy. Ethanol above a concentration of 28% leads to plasma protein precipitation. Ethanol locks were associated with catheter occlusion in 11 studies and independently increased the risk of thrombosis compared with heparin lock in a randomized trial. Six studies noted abnormalities in catheter integrity, including one case leading to catheter embolization. Of note, five of these studies involved silicone catheters. Ethanol lock use was associated with systemic side effects in 10 studies and possible side effects in one additional study. Four studies noted liver function test abnormalities, predominantly transaminase elevation, related to ethanol lock use. However, a prospective study did not find any difference in the risk of doubling the transaminase level above the normal range during use of ethanol locks compared with not using an ethanol lock. The use of ethanol locks has been associated with structural changes in catheters, as well as the elution of molecules from the catheter polymers. Clinical studies have revealed systemic toxicity, increased catheter occlusion and breaches in catheter integrity. © The Author 2014. Published by Oxford University Press on

  18. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  19. Deep-red semiconductor monolithic mode-locked lasers

    International Nuclear Information System (INIS)

    Kong, L.; Bajek, D.; White, S. E.; Forrest, A. F.; Cataluna, M. A.; Wang, H. L.; Pan, J. Q.; Wang, X. L.; Cui, B. F.; Ding, Y.

    2014-01-01

    A deep-red semiconductor monolithic mode-locked laser is demonstrated. Multi-section laser diodes based on an AlGaAs multi-quantum-well structure were passively mode-locked, enabling the generation of picosecond optical pulses at 752 nm, at pulse repetition rates of 19.37 GHz. An investigation of the dependence of the pulse duration as a function of reverse bias revealed a predominantly exponential decay trend of the pulse duration, varying from 10.5 ps down to 3.5 ps, which can be associated with the concomitant reduction of absorption recovery time with increasing applied field. A 30-MHz-tunability of the pulse repetition rate with bias conditions is also reported. The demonstration of such a compact, efficient and versatile ultrafast laser in this spectral region paves the way for its deployment in a wide range of applications such as biomedical microscopy, pulsed terahertz generation as well as microwave and millimeter-wave generation, with further impact on sensing, imaging and optical communications

  20. Automated Identification of MHD Mode Bifurcation and Locking in Tokamaks

    Science.gov (United States)

    Riquezes, J. D.; Sabbagh, S. A.; Park, Y. S.; Bell, R. E.; Morton, L. A.

    2017-10-01

    Disruption avoidance is critical in reactor-scale tokamaks such as ITER to maintain steady plasma operation and avoid damage to device components. A key physical event chain that leads to disruptions is the appearance of rotating MHD modes, their slowing by resonant field drag mechanisms, and their locking. An algorithm has been developed that automatically detects bifurcation of the mode toroidal rotation frequency due to loss of torque balance under resonant braking, and mode locking for a set of shots using spectral decomposition. The present research examines data from NSTX, NSTX-U and KSTAR plasmas which differ significantly in aspect ratio (ranging from A = 1.3 - 3.5). The research aims to examine and compare the effectiveness of different algorithms for toroidal mode number discrimination, such as phase matching and singular value decomposition approaches, and to examine potential differences related to machine aspect ratio (e.g. mode eigenfunction shape variation). Simple theoretical models will be compared to the dynamics found. Main goals are to detect or potentially forecast the event chain early during a discharge. This would serve as a cue to engage active mode control or a controlled plasma shutdown. Supported by US DOE Contracts DE-SC0016614 and DE-AC02-09CH11466.

  1. Rehabilitation in locked-in-syndrome – a case study

    Directory of Open Access Journals (Sweden)

    Anna Grabowska

    2017-03-01

    Full Text Available Introduction: The locked-in syndrome is a neurological condition which occurs most often as a result of brainstem stroke, characterized by the presence of sustained eye opening, aphonia or severe hypophonia, quadriplegia or quadriparesis, preserved cognitive functioning, and a primary and elementary code of communication using vertical eye movements or blinking. This illness leads to complete physical disability of the person, accompanied with fully retained mental capability. Case study: The goal of the hereby work is to present a description of a case of a person with the locked-in syndrome, caused by ischemic stroke of the pons and left cerebellar hemisphere. The prognosis of improvement in LIS is bad. The patient has to adapt to the new, difficult situation that will probably accompany him for whole life. The article presents the therapeutic process from the onset through physical rehabilitation,  speech therapy and psychological  therapy until return home. The process requires patience from the patient and therapists and family members. Conclusion: Research in this area is supposed to help in planning of cooperation the entire medical team of doctors, nurses, physiotherapists, social workers, speech therapists and neuropsychologists. Interdisciplinary proceedings can greatly help to achieve even a minimal degree of independence and autonomy.

  2. Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive

    Science.gov (United States)

    Hernandez, Alan; Hess, Daniel P.

    2016-01-01

    This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.

  3. The locking-decoding frontier for generic dynamics.

    Science.gov (United States)

    Dupuis, Frédéric; Florjanczyk, Jan; Hayden, Patrick; Leung, Debbie

    2013-11-08

    It is known that the maximum classical mutual information, which can be achieved between measurements on pairs of quantum systems, can drastically underestimate the quantum mutual information between them. In this article, we quantify this distinction between classical and quantum information by demonstrating that after removing a logarithmic-sized quantum system from one half of a pair of perfectly correlated bitstrings, even the most sensitive pair of measurements might yield only outcomes essentially independent of each other. This effect is a form of information locking but the definition we use is strictly stronger than those used previously. Moreover, we find that this property is generic, in the sense that it occurs when removing a random subsystem. As such, the effect might be relevant to statistical mechanics or black hole physics. While previous works had always assumed a uniform message, we assume only a min-entropy bound and also explore the effect of entanglement. We find that classical information is strongly locked almost until it can be completely decoded. Finally, we exhibit a quantum key distribution protocol that is 'secure' in the sense of accessible information but in which leakage of even a logarithmic number of bits compromises the secrecy of all others.

  4. Locked magnetic island chains in toroidally flow damped tokamak plasmas

    International Nuclear Information System (INIS)

    Fitzpatrick, R; Waelbroeck, F L

    2010-01-01

    The physics of a locked magnetic island chain maintained in the pedestal of an H-mode tokamak plasma by a static, externally generated, multi-harmonic, helical magnetic perturbation is investigated. The non-resonant harmonics of the external perturbation are assumed to give rise to significant toroidal flow damping in the pedestal, in addition to the naturally occurring poloidal flow damping. Furthermore, the flow damping is assumed to be sufficiently strong to relax the pedestal ion toroidal and poloidal fluid velocities to fixed values determined by neoclassical theory. The resulting neoclassical ion flow causes a helical phase-shift to develop between the locked island chain and the resonant harmonic of the external perturbation. Furthermore, when this phase-shift exceeds a critical value, the chain unlocks from the resonant harmonic and starts to rotate, after which it decays away and is replaced by a helical current sheet. The neoclassical flow also generates an ion polarization current in the vicinity of the island chain which either increases or decreases the chain's radial width, depending on the direction of the flow. If the polarization effect is stabilizing, and exceeds a critical amplitude, then the helical island equilibrium becomes unstable, and the chain again decays away. The critical amplitude of the resonant harmonic of the external perturbation at which the island chain either unlocks or becomes unstable is calculated as a function of the pedestal ion pressure, the neoclassical poloidal and toroidal ion velocities and the poloidal and toroidal flow damping rates.

  5. Gamma power is phase-locked to posterior alpha activity.

    Directory of Open Access Journals (Sweden)

    Daria Osipova

    Full Text Available Neuronal oscillations in various frequency bands have been reported in numerous studies in both humans and animals. While it is obvious that these oscillations play an important role in cognitive processing, it remains unclear how oscillations in various frequency bands interact. In this study we have investigated phase to power locking in MEG activity of healthy human subjects at rest with their eyes closed. To examine cross-frequency coupling, we have computed coherence between the time course of the power in a given frequency band and the signal itself within every channel. The time-course of the power was calculated using a sliding tapered time window followed by a Fourier transform. Our findings show that high-frequency gamma power (30-70 Hz is phase-locked to alpha oscillations (8-13 Hz in the ongoing MEG signals. The topography of the coupling was similar to the topography of the alpha power and was strongest over occipital areas. Interestingly, gamma activity per se was not evident in the power spectra and only became detectable when studied in relation to the alpha phase. Intracranial data from an epileptic subject confirmed these findings albeit there was slowing in both the alpha and gamma band. A tentative explanation for this phenomenon is that the visual system is inhibited during most of the alpha cycle whereas a burst of gamma activity at a specific alpha phase (e.g. at troughs reflects a window of excitability.

  6. CMOS Optoelectronic Lock-In Amplifier With Integrated Phototransistor Array.

    Science.gov (United States)

    An Hu; Chodavarapu, Vamsy P

    2010-10-01

    We describe the design and development of an optoelectronic lock-in amplifier (LIA) for optical sensing and spectroscopy applications. The prototype amplifier is fabricated using Taiwan Semiconductor Manufacturing Co. complementary metal-oxide semiconductor 0.35-μm technology and uses a phototransistor array (total active area is 400 μm × 640μm) to convert the incident optical signals into electrical currents. The photocurrents are then converted into voltage signals using a transimpedance amplifier for subsequent convenient signal processing by the LIA circuitry. The LIA is optimized to be operational at 20-kHz modulation frequency but is operational in the frequency range from 13 kHz to 25 kHz. The system is tested with a light-emitting diode (LED) as the light source. The noise and signal distortions are suppressed with filters and a phase-locked loop (PLL) implemented in the LIA. The output dc voltage of the LIA is proportional to the incident optical power. The minimum measured dynamic reserve and sensitivity are 1.31 dB and 34 mV/μW, respectively. The output versus input relationship has shown good linearity. The LIA consumes an average power of 12.79 mW with a 3.3-V dc power supply.

  7. Injection locking method for Raman beams in atom interferometer

    Science.gov (United States)

    Zi, Fei; Deng, Jianing; Zeng, Daji; Li, Tong; Sun, Mingli; Zhang, Xian; Huang, Kaikai; Lu, Xuanhui

    2018-03-01

    We present a novel method to generate two phase-locked beams with a frequency offset of 6.834 GHz. The output of the master laser is firstly modulated by an electric optical modulator (EOM), and then further injected into an Extended Cavity Diode Lasers (ECDL) which is used to filter out the unwanted mode and amplify the laser power. By locking to the first-order lower sideband of the modulated master laser, the average variance of the phase fluctuations is 5.6 x 10-3 rad2 , which implies phase coherence of 99.44% between the master laser and the slave ECDL. The line width of the beat notes is less than 1Hz. For the long term stability, with the delicate design of the electronic controller in ECDL, the phase coherence of the two laser beams can be stabilized over 200 hours without any adjustment. The Raman system is applicable for gravity detection with a preliminary sensitivity Δg/g of 4.5 x 10-7 for interrogation time of 1500 s.

  8. Performance Characterization of Loctite (Registered Trademark) 242 and 271 Liquid Locking Compounds (LLCs) as a Secondary Locking Feature for International Space Station (ISS) Fasteners

    Science.gov (United States)

    Dube, Michael J.; Gamwell, Wayne R.

    2011-01-01

    Several International Space Station (ISS) hardware components use Loctite (and other polymer based liquid locking compounds (LLCs)) as a means of meeting the secondary (redundant) locking feature requirement for fasteners. The primary locking method is the fastener preload, with the application of the Loctite compound which when cured is intended to resist preload reduction. The reliability of these compounds has been questioned due to a number of failures during ground testing. The ISS Program Manager requested the NASA Engineering and Safety Center (NESC) to characterize and quantify sensitivities of Loctite being used as a secondary locking feature. The findings and recommendations provided in this investigation apply to the anaerobic LLCs Loctite 242 and 271. No other anaerobic LLCs were evaluated for this investigation. This document contains the findings and recommendations of the NESC investigation

  9. Development of a novel method for surgical implant design optimization through noninvasive assessment of local bone properties.

    Science.gov (United States)

    Schiuma, D; Brianza, S; Tami, A E

    2011-03-01

    A method was developed to improve the design of locking implants by finding the optimal paths for the anchoring elements, based on a high resolution pQCT assessment of local bone mineral density (BMD) distribution and bone micro-architecture (BMA). The method consists of three steps: (1) partial fixation of the implant to the bone and creation of a reference system, (2) implant removal and pQCT scan of the bone, and (3) determination of BMD and BMA of all implant-anchoring locations along the actual and alternative directions. Using a PHILOS plate, the method uncertainty was tested on an artificial humerus bone model. A cadaveric humerus was used to quantify how the uncertainty of the method affects the assessment of bone parameters. BMD and BMA were determined along four possible alternative screw paths as possible criteria for implant optimization. The method is biased by a 0.87 ± 0.12 mm systematic uncertainty and by a 0.44 ± 0.09 mm random uncertainty in locating the virtual screw position. This study shows that this method can be used to find alternative directions for the anchoring elements, which may possess better bone properties. This modification will thus produce an optimized implant design. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Navigation Conditions at Gray's Landing Locks and Dam, Monongahela River; Hydraulic Model Investigation

    National Research Council Canada - National Science Library

    Wooley, Ronald

    1998-01-01

    .... The river drains an area of 7,386 square miles and drops a total of 147 ft in its 128.7-mile length. Gray's Landing Lock and Dam is a proposed replacement structure for existing Lock and Dam 7 on the Monongahela River...

  11. Phase locking and spectral linewidth of a two-mode terahertz quantum cascade laser

    NARCIS (Netherlands)

    Baryshev, A.; Hovenier, J.N.; Adam, A.J.L.; Kašalynas, I.; Gao, J.R.; Klaassen, T.O.; Williams, B.S.; Kumar, S.; Hu, Q.; Reno, J.L.

    2006-01-01

    We have studied the phase locking and spectral linewidth of an ? 2.7?THz quantum cascade laser by mixing its two lateral lasing modes. The beat signal at about 8?GHz is compared with a microwave reference by applying conventional phase lock loop circuitry with feedback to the laser bias current.

  12. Comparison of the noise performance of 10GHz QW and QD mode-locked laser diodes

    DEFF Research Database (Denmark)

    Carpintero, Guillermo; Thompson, Mark G.; Yvind, Kresten

    2010-01-01

    This paper reports the experimental characterization of the noise performance of a quantum dot and a quantum well 10GHz passive mode locked laser diodes.......This paper reports the experimental characterization of the noise performance of a quantum dot and a quantum well 10GHz passive mode locked laser diodes....

  13. Narrow-band modulation of semiconductor lasers at millimeter wave frequencies (7100 GHz) by mode locking

    International Nuclear Information System (INIS)

    Lau, K.Y.

    1990-01-01

    This paper reports on the possibility of mode locking a semiconductor laser at millimeter wave frequencies approaching and beyond 100 GHz which was investigated theoretically and experimentally. It is found that there are no fundamental theoretical limitations in mode locking at frequencies below 100 GHz. AT these high frequencies, only a few modes are locked and the output usually takes the form of a deep sinusoidal modulation which is synchronized in phase with the externally applied modulation at the intermodal heat frequency. This can be regarded for practical purposes as a highly efficient means of directly modulating an optical carrier over a narrow band at millimeter wave frequencies. Both active and passive mode locking are theoretically possible. Experimentally, predictions on active mode locking have been verified in prior publications up to 40 GHz. For passive mode locking, evidence consistent with passive mode locking was observed in an inhomogeneously pumped GaAIAs laser at a frequency of approximately 70 GHz. A large differential gain-absorption ratio such as that present in an inhomogeneously pumped single quantum well laser is necessary for pushing the passive mode-locking frequency beyond 100 GHz

  14. An inverted-geometry, high voltage polarized electron gun with UHV load lock

    International Nuclear Information System (INIS)

    Breidenbach, M.; Foss, M.; Hodgson, J.; Kulikov, A.; Odian, A.; Putallaz, G.; Rogers, H.; Schindler, R.; Skarpaas, K.; Zolotorev, M.

    1994-01-01

    The design of a high voltage electron source with a GaAs photocathode and a load lock system is described. The inverted high voltage structure of the gun permits a compact and simple design. Test results demonstrate that the load lock system provides a reliable way to achieve high quantum efficiency of the photocathode in a high voltage device. ((orig.))

  15. Passively model-locked Nd: YAG laser with a component GaAs

    International Nuclear Information System (INIS)

    Zhang Zhuhong; Qian Liejia; Chen Shaohe; Fan Dianyuan; Mao Hongwei

    1992-01-01

    An all solid-state passively mode-locked Nd: YAG laser with a 400 μm, (100) oriented GaAs component is reported for the first time and model locked pulses with a duration of 16 ps, average energy of 10 μJ were obtained with a probability of 90%

  16. Phase locking and spectral linewidth of a two-mode terahertz quantum cascade laser

    NARCIS (Netherlands)

    Baryshev, A.; Hovenier, J. N.; Adam, A. J. L.; Kašalynas, I.; Gao, J. R.; Klaassen, T. O.; Williams, B. S.; Kumar, S.; Hu, Q.; Reno, J. L.

    2006-01-01

    We have studied the phase locking and spectral linewidth of an ˜2.7THz quantum cascade laser by mixing its two lateral lasing modes. The beat signal at about 8GHz is compared with a microwave reference by applying conventional phase lock loop circuitry with feedback to the laser bias current. Phase

  17. Locked nucleic acid (LNA): High affinity targeting of RNA for diagnostics and therapeutics

    DEFF Research Database (Denmark)

    Kauppinen, S.; Vester, Birte; Wengel, Jesper

    2005-01-01

    Locked nucleic acid (LNA) is a nucleic acid analogue containing one or more LNA nucleotide monomers with a bicyclic furanose unit locked in an RNA mimicking sugar conformation. This conformational restriction results in unprecedented hybridization affinity towards complementary single stranded RN...

  18. 78 FR 77115 - Lock 14 Hydro Partners; Notice of Application Ready for Environmental Analysis and Soliciting...

    Science.gov (United States)

    2013-12-20

    ...: Federal Power Act, 16 U.S.C. 791(a)-825(r). h. Applicant Contact: David Brown Kinloch, Lock 14 Hydro... of: (1) An existing 248-foot- long, 17-foot-high concrete lock and dam with a 319-foot-long stone...

  19. Independent tunability of the double-mode-locked cw dye laser.

    LENUS (Irish Health Repository)

    Bourkoff, E

    1979-06-01

    We report a new configuration that enables the double-mode-locked cw dye laser to be independently tunable. In addition, the output coupling at each of the two wavelengths can be independently specified. A series of oscillographs shows some interesting features unique to double mode locking and also shows the effects of varying the two cavity lengths with respect to each other.

  20. Numerical investigations on the performance of external-cavity mode-locked semiconductor lasers

    DEFF Research Database (Denmark)

    Mulet, Josep; Mørk, Jesper

    2004-01-01

    The performance of an external-cavity mode-locked semiconductor laser is analyzed theoretically and numerically. Passive mode-locking is described using a fully-distributed time-domain model including fast effects, spectral hole burning and carrier heating. We provide optimization rules in order ...