WorldWideScience

Sample records for plasma volume decrease

  1. Plasma volume changes during hypoglycaemia

    DEFF Research Database (Denmark)

    Hilsted, J; Frandsen, Henrik Lund; Christensen, N J

    1991-01-01

    -induced hypoglycaemia with total autonomic blockade (alpha-adrenoceptor blockade combined with beta-adrenoceptor blockade and atropine); and insulin-induced hypoglycaemia without any autonomic blockade. In the experiments without autonomic blockade the peripheral venous hematocrit increased, plasma volume decreased......, intravascular albumin content decreased and the transcapillary escape rate of albumin increased. In both experiments with autonomic blockade the increase in venous haematocrit was abolished, yet plasma volume decreased, intravascular albumin content decreased and the transcapillary escape rate of albumin...... increased in these experiments. Thus, the changes in plasma volume and composition in response to hypoglycaemia are due to the combined actions of adrenaline and of insulin....

  2. Plasma volume changes during hypoglycaemia

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  3. Dual effect of insulin on plasma volume and transcapillary albumin transport

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J

    1992-01-01

    vascular dilatation and increased muscle sympathetic nerve activity during a euglycaemic glucose clamp. During similar conditions insulin increased the transcapillary escape rate of albumin and reduced plasma volume. Insulin has also an indirect effect on vascular permeability during hypoglycaemia, which...... is mediated by the increase in plasma adrenaline. Adrenaline infusion increased haematocrit and decreased plasma volume and intravascular albumin mass. In contrast to insulin adrenaline did not increase the transcapillary escape rate of albumin. Total autonomic blockade during insulin-induced hypoglycaemia...... abolished the increase in haematocrit, but did not influence the decrease in plasma volume and the increase in the transcapillary escape rate of albumin. Insulin administration may also increase urinary albumin excretion, and this effect was observed during a euglycaemic clamp. The mechanism of the increase...

  4. Plasma volume, osmolality, vasopressin, and renin activity during graded exercise in man

    Science.gov (United States)

    Convertino, V. A.; Keil, L. C.; Bernauer, E. M.; Greenleaf, J. E.

    1981-01-01

    The influence of work intensity on plasma volume, osmolality, vasopressin and renin activity and the interrelationships between these responses are investigated. Plasma volume, renin activity and osmotic, sodium and arginine vasopressin concentrations were measured in venous blood samples taken from 15 healthy male subjects before and after six minutes of bicycle ergometer exercise at 100, 175 and 225 W. Plasma volume is found to decrease significantly with increasing work intensity, while increases in Na(+) concentration, osmolality and vasopressin are only observed to be significant when the work intensity exceeds 40% maximal aerobic capacity and plasma resin activity increased linearly at all work levels. In addition, significant correlations are observed between plasma volume and osmolality and sodium changes, and between vasopressin and osmolality and sodium content changes. Data thus support the hypotheses that (1) vasopressin may be the primary controlling endocrine for fluid and electrolyte levels following exercise; (2) an exercise intensity greater than 40% maximal aerobic capacity is required to stimulate vasopressin release through changes in plasma osmolality; and (3) the stimulation of the renin-angiotensin system is a more general stress response.

  5. [Measurement of maternal plasma volume during pregnancy].

    Science.gov (United States)

    Uzan, S; Beaufils, M; Uzan, M; Donsimoni, R; Mareck, A; Salat-Baroux, J; Sureau, C

    1988-02-01

    An increased maternal plasma volume (PV) is a characteristic phenomenon of normal pregnancy, which may be related to a physiological decrease of peripheral resistances. The authors have studied the plasma volume of 1,105 patients distributed as follows: normal (387), permanently hypertensive patients (84), hypertensive patients during pregnancy (390), patients with apparently isolated RCIU (154) or with a pathological past-history during previous pregnancies (90). It appears that the PV is a sign of a severe HBP, and presents a rather early and good predictive value regarding the weight of the fetus and some complications such as severe UCIU and fetal death in utero. In case of pathological past events or pre-existing hypertension, the PV enables to differentiate rather well patients who will be prone to a complicated pregnancy. In view of these results, utilization and interpretation criteria of this parameter during pregnancies with hypertension or pregnancies in which there is a suspicion or a risk of intra-uterine growth delay, are defined.

  6. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  7. Plasma volume, intravascular albumin and its transcapillary escape rate in patients with extensive skin disease

    DEFF Research Database (Denmark)

    Parving, H H; Worm, A M; Rossing, N

    1976-01-01

    Plasma volume and plasma concentration and transcapillary escape rate of albumin (TER alb), i.e. the fraction of intravascular mass of albumin that passes to the extravascular space per unit time, were determined using 125I-labelled human albumin in eight patients with extensive skin disease....... Plasma volume and plasma albumin concentration were reduced (P less than 0-05). Thus the intravascular albumin mass was moderately decreased to an average of 0-55 +/- 0-06 (s.d.) g/cm height compared with a normal mean value of 0-77 +/- 0-07 (s.d.) g/cm. This 29% decrease is statistically significant (P...... less than 0-001). The transcapillary escape rate of albumin (TER alb) was significantly elevated, mean 8-6 +/- 1-1 (s.d.) % X h-1, as compared to normal subjects, mean 5-6 +/- 1-1 (s.d.) % X h-1, (+54%, P less than 0-001). The same patients were studied again after a 1-week treatment with prednisone...

  8. Plasma Volume Expansion Resulting from Intravenous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2011-01-01

    Full Text Available Objective. To quantify the degree of plasma volume expansion that occurs during an intravenous glucose tolerance test (IVGTT. Methods. Twenty healthy volunteers (mean age, 28 years underwent IVGTTs in which 0.3 g/kg of glucose 30% was injected as a bolus over 1 min. Twelve blood samples were collected over 75 min. The plasma glucose and blood hemoglobin concentrations were used to calculate the volume distribution (Vd and the clearance (CL of both the exogenous glucose and the injected fluid volume. Results. The IVGTT caused a virtually instant plasma volume expansion of 10%. The half-life of the glucose averaged 15 min and the plasma volume expansion 16 min. Correction of the fluid kinetic model for osmotic effects after injection reduced CL for the infused volume by 85%, which illustrates the strength of osmosis in allocating fluid back to the intracellular fluid space. Simulations indicated that plasma volume expansion can be reduced to 60% by increasing the injection time from 1 to 5 min and reducing the glucose load from 0.3 to 0.2 g/kg. Conclusion. A regular IVGTT induced an acute plasma volume expansion that peaked at 10% despite the fact that only 50–80 mL of fluid were administered.

  9. Beta-Adrenergic Blockade Does not Prevent Polycythemia or Decrease in Plasma Volume in Men at 4300 m Altitude

    Science.gov (United States)

    Grover, R. F.; Selland, M. A.; McCullough, R. G.; Dahms, T. E.; Wolfel, E. E.; Butterfield, G. E.; Reeves, J. T.; Greenleaf, J. E.

    1998-01-01

    When humans ascend to high altitude (ALT) their plasma volume (PV) and total blood volume (BV) decrease during the first few days. With continued residence over several weeks, the hypoxia-induced stimulation of erythropoietin increases red cell production which tends to restore BV. Because hypoxia also activates the beta-adrenergic system, which stimulates red blood cell production, we investigated the effect of adrenergic beta-receptor inhibition with propranolol on fluid volumes and the polycythemic response in 11 healthy unacclimatized men (21-33 years old exposed to an ALT of 4300 m (barometric pressure 460 Torr) for 3 weeks on Pikes Peak, Colorado. PV was determined by the Evans blue dye method (PV(sub EB)), BV by the carbon monoxide method (BV(sub CO)), red cell volume (RCV)was calculated from hematocrit (Hct) and BV(sub CO), and serum erythropoietin concentration ([EPO]) and reticulocyte count, were also determined. All determinations were made at sea level and after 9-11 (ALT-10) and 9-20 (ALT-20) days at ALT. At sea level and ALT, six men received propranolol (pro, 240 mg/day), and five received a placebo (pla). Effective beta-blockade did not modify the mean (SE) maximal values of [EPO] [pla: 24.9 (3.5) vs pro: 24.5 (1.5) mU/ml] or reticulocyte count [pla: 2.7 (0.7) vs pro: 2.2 (0.5)%]; nor changes in PV(sub EB)[pla: -15.8 (3.8) vs pro: -19.9 (2.8)%], RCV(sub CO) [pla: +7.0 (6.7) vs pro: +10.1 (6.1)%], or BV(sub CO) [pla: -7.3 (2.3) vs pro: -7.1 (3.9)%]. In the absence of weight loss, a redistribution of body water with no net loss is implied. Hence, activation of the beta-adrenergic system did not appear to affect the hypovolemic or polycythemic responses that occurred during 3 weeks at 4300 m ALT in these subjects.

  10. Low Plasma Volume in Normotensive Formerly Preeclamptic Women Predisposes to Hypertension.

    Science.gov (United States)

    Scholten, Ralph R; Lotgering, Fred K; Hopman, Maria T; Van Dijk, Arie; Van de Vlugt, Maureen; Janssen, Mirian C H; Spaanderman, Marc E A

    2015-11-01

    Formerly preeclamptic women are at risk for cardiovascular disease. Low plasma volume may reflect latent hypertension and potentially links preeclampsia with chronic cardiovascular disease. We hypothesized that low plasma volume in normotensive formerly preeclamptic women predisposes to hypertension. We longitudinally studied n=104 formerly preeclamptic women in whom plasma volume was measured 3 to 30 months after the preeclamptic pregnancy. Cardiovascular variables were assessed at 2 points in time (3-30 months postpartum and 2-5 years thereafter). Study population was divided into low plasma volume (≤1373 mL/m(2)) and normal plasma volume (>1373 mL/m(2)). Primary end point was hypertension at the second visit: defined as ≥140 mm Hg systolic or ≥90 mm Hg diastolic. Secondary outcome of this study was change in traditional cardiovascular risk profile between visits. Variables correlating univariately with change in blood pressure between visits were introduced in regression analysis. Eighteen of 104 (17%) formerly preeclamptic women who were normotensive at first visit had hypertension at second evaluation 2 to 5 years later. Hypertension developed more often in women with low plasma volume (10/35 [29%]) than in women with normal plasma volume (8/69 [12%]; odds ratio, 3.2; 95% confidence interval, 1.4-8.6). After adjustments, relationship between plasma volume status and subsequent hypertension persisted (adjusted odds ratio, 3.0; 95% confidence interval, 1.1-8.5). Mean arterial pressure at second visit correlated inverse linearly with plasma volume (r=-0.49; Phypertension within 5 years. Women with low plasma volume have higher chance to develop hypertension than women with normal plasma volume. Clinically, follow-up of blood pressure seems warranted in women with history of preeclampsia, even when initially normotensive. © 2015 American Heart Association, Inc.

  11. Effect of Intravenous Small-Volume Hypertonic Sodium Bicarbonate, Sodium Chloride, and Glucose Solutions in Decreasing Plasma Potassium Concentration in Hyperkalemic Neonatal Calves with Diarrhea.

    Science.gov (United States)

    Trefz, F M; Constable, P D; Lorenz, I

    2017-05-01

    Hyperkalemia is a frequently observed electrolyte imbalance in dehydrated neonatal diarrheic calves that can result in skeletal muscle weakness and life-threatening cardiac conduction abnormalities and arrhythmias. Intravenous administration of a small-volume hypertonic NaHCO 3 solution is clinically more effective in decreasing the plasma potassium concentration (cK) in hyperkalemic diarrheic calves than hypertonic NaCl or glucose solutions. Twenty-two neonatal diarrheic calves with cK >5.8 mmol/L. Prospective randomized clinical trial. Calves randomly received either 8.4% NaHCO 3 (6.4 mL/kg BW; n = 7), 7.5% NaCl (5 mL/kg BW; n = 8), or 46.2% glucose (5 mL/kg BW; n = 7) IV over 5 minutes and were subsequently allowed to suckle 2 L of an electrolyte solution. Infusions with NaHCO 3 and NaCl provided an identical sodium load of 6.4 mmol/kg BW. Hypertonic NaHCO 3 infusions produced an immediate and sustained decrease in plasma cK. Hypertonic glucose infusions resulted in marked hyperglycemia and hyperinsulinemia, but cK remained unchanged for 20 minutes. Between 30 and 120 minutes after initiation of treatment, the most marked decrements in cK from baseline occurred in group NaHCO 3 , which were significantly (P < .05) larger during this period of time than in calves in group NaCl, but not group glucose. After 120 minutes, the mean decrease in cK from baseline was -26 ± 10%, -9 ± 8%, and -22 ± 6% in groups NaHCO 3 , NaCl, and glucose, respectively. Small-volume hypertonic NaHCO 3 infusions appear to have clinical advantages for the rapid resuscitation of hyperkalemic diarrheic calves, compared to hypertonic NaCl or glucose solutions. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. The volume-expanding effects of autologous liquid stored plasma following hemorrhage

    DEFF Research Database (Denmark)

    Bentzer, Peter; Thomas, Owain D; Westborg, Johan

    2012-01-01

    of plasma transfusion on plasma volume. We report a prospective interventional study in which the plasma volume-expanding effect of autologous plasma was investigated after a controlled hemorrhage. Methods. Plasma obtained by plasmapheresis from nine healthy regular blood donors was stored at 2-6°C. Five...

  13. blood and plasma volumes in normal west african dwarf sheep

    African Journals Online (AJOL)

    Dr Olaleye

    volume (PCV) and haemoglobin (Hb) values were determined as descried by Benjamin (1978) using the microhaematocrit and ... Standard dye concentration of 20 mg/ml was used for determining the dye concentration in plasma. ... Haemoglobin (Hb), Plasma Volume and Blood Volume in the West African Dwarf. Sheep.

  14. Effect of large volume paracentesis on plasma volume--a cause of hypovolemia

    International Nuclear Information System (INIS)

    Kao, H.W.; Rakov, N.E.; Savage, E.; Reynolds, T.B.

    1985-01-01

    Large volume paracentesis, while effectively relieving symptoms in patients with tense ascites, has been generally avoided due to reports of complications attributed to an acute reduction in intravascular volume. Measurements of plasma volume in these subjects have been by indirect methods and have not uniformly confirmed hypovolemia. We have prospectively evaluated 18 patients (20 paracenteses) with tense ascites and peripheral edema due to chronic liver disease undergoing 5 liter paracentesis for relief of symptoms. Plasma volume pre- and postparacentesis was assessed by a 125 I-labeled human serum albumin dilution technique as well as by the change in hematocrit and postural blood pressure difference. No significant change in serum sodium, urea nitrogen, hematocrit or postural systolic blood pressure difference was noted at 24 or 48 hr after paracentesis. Serum creatinine at 24 hr after paracentesis was unchanged but a small but statistically significant increase in serum creatinine was noted at 48 hr postparacentesis. Plasma volume changed -2.7% (n = 6, not statistically significant) during the first 24 hr and -2.8% (n = 12, not statistically significant) during the 0- to 48-hr period. No complications from paracentesis were noted. These results suggest that 5 liter paracentesis for relief of symptoms is safe in patients with tense ascites and peripheral edema from chronic liver disease

  15. A high plasma: red blood cell transfusion ratio during liver transplantation is associated with decreased blood utilization.

    Science.gov (United States)

    Pagano, M B; Metcalf, R A; Hess, J R; Reyes, J; Perkins, J D; Montenovo, M I

    2018-04-01

    During massive transfusion, the volume ratio of administered plasma (PL Vol) to red blood cell (RBC Vol) appears to be associated with reduced blood utilization and improved survival. The aim of this study was to evaluate the optimal component ratio in the setting of liver transplantation. This is a retrospective chart review of patients who underwent liver transplantation and received at least 500 ml of red blood cells from January 2013 through December 2015. Kernel smoothing analysis determined the proper component ratios to evaluate were a ≥0·85:1 ratio (high) to a ≤0·85:1 ratio (low). Two groups, plasma volume to RBC volume (PL Vol/RBC Vol) and plasma contained in the platelet units added to the plasma calculation [PL + PLT (platelet)] Vol/RBC Vol, were used to evaluate the component ratios. A total of 188 patients were included in the analysis. In the PL Vol/RBC Vol evaluation, a low ratio revealed that 1238 ml (977-1653 ml) (P ratio, in the univariable and multivariable analysis, respectively. In the PL +PLT Vol/RBC Vol evaluation, a low ratio used 734 ml (193-1275) (P = 0·008) and 886 ml (431-1340) (P ratio in the univariable and multivariable analysis, respectively. In patients undergoing liver transplantation, the transfusion of plasma to RBC ratio ≥0·85 was associated with decreased need of RBC transfusions. © 2018 International Society of Blood Transfusion.

  16. Supplementation with Folic Acid, but Not Creatine, Increases Plasma Betaine, Decreases Plasma Dimethylglycine, and Prevents a Decrease in Plasma Choline in Arsenic-Exposed Bangladeshi Adults.

    Science.gov (United States)

    Hall, Megan N; Howe, Caitlin G; Liu, Xinhua; Caudill, Marie A; Malysheva, Olga; Ilievski, Vesna; Lomax-Luu, Angela M; Parvez, Faruque; Siddique, Abu B; Shahriar, Hasan; Uddin, Mohammad N; Islam, Tariqul; Graziano, Joseph H; Gamble, Mary V

    2016-05-01

    Folic acid (FA) supplementation facilitates urinary excretion of arsenic, a human carcinogen. A better understanding of interactions between one-carbon metabolism intermediates may improve the ability to design nutrition interventions that further facilitate arsenic excretion. The objective was to determine if FA and/or creatine supplementation increase choline and betaine and decrease dimethylglycine (DMG). We conducted a secondary analysis of the Folic Acid and Creatine Trial, a randomized trial in arsenic-exposed Bangladeshi adults (n = 605, aged 24-55 y, 50.3% male) who received arsenic-removal water filters. We examined treatment effects of FA and/or creatine supplementation on plasma choline, betaine, and DMG concentrations, measured by LC-tandem mass spectrometry at baseline and at week 12. Group comparisons were between 1) 400 and 800 μg FA/d (FA400 and FA800, respectively) compared with placebo, 2) creatine (3 g/d) compared with placebo, and 3) creatine plus FA400 compared with FA400. Choline decreased in the placebo group (-6.6%; 95% CI: -10.2%, -2.9%) but did not change in the FA groups (FA400: 2.5%; 95% CI: -0.9%, 6.1%; FA800: 1.4%; 95% CI: -2.5%, 5.5%; P creatine treatment arms and their respective reference groups. Supplementation for 12 wk with FA, but not creatine, increases plasma betaine, decreases plasma DMG, and prevents a decrease in plasma choline in arsenic-exposed Bangladeshi adults. This trial was registered at clinicaltrials.gov as NCT01050556. © 2016 American Society for Nutrition.

  17. Plasma volume in acute hypoxia

    DEFF Research Database (Denmark)

    Poulsen, T D; Klausen, T; Richalet, J P

    1998-01-01

    Exposure to acute hypoxia is associated with changes in body fluid homeostasis and plasma volume (PV). This study compared a dye dilution technique using Evans' blue (PV[Evans']) with a carbon monoxide (CO) rebreathing method (PV[CO]) for measurements of PV in ten normal subjects at sea level...

  18. Coupling of RF antennas to large volume helicon plasma

    Directory of Open Access Journals (Sweden)

    Lei Chang

    2018-04-01

    Full Text Available Large volume helicon plasma sources are of particular interest for large scale semiconductor processing, high power plasma propulsion and recently plasma-material interaction under fusion conditions. This work is devoted to studying the coupling of four typical RF antennas to helicon plasma with infinite length and diameter of 0.5 m, and exploring its frequency dependence in the range of 13.56-70 MHz for coupling optimization. It is found that loop antenna is more efficient than half helix, Boswell and Nagoya III antennas for power absorption; radially parabolic density profile overwhelms Gaussian density profile in terms of antenna coupling for low-density plasma, but the superiority reverses for high-density plasma. Increasing the driving frequency results in power absorption more near plasma edge, but the overall power absorption increases with frequency. Perpendicular stream plots of wave magnetic field, wave electric field and perturbed current are also presented. This work can serve as an important reference for the experimental design of large volume helicon plasma source with high RF power.

  19. Immunoglobulin G levels during collection of large volume plasma for fractionation.

    Science.gov (United States)

    Burkhardt, Thomas; Rothe, Remo; Moog, Rainer

    2017-06-01

    There is a need of comprehensive work dealing with the quality of plasma for fractionation with respect to the IgG content as today most plasma derivates are used to treat patients with immunodeficiencies and autoimmune disorders. Therefore, a prospective study was carried out to analyse IgG levels before plasmapheresis and every 200ml collected plasma. Fifty-four experienced plasmapheresis donors were recruited for subsequent 850ml plasmapheresis using the Aurora Plasmapheresis System. Donorś peripheral blood counts were analysed before and after plasmapheresis using an electronic counter. Total protein, IgG and citrate were measured turbidometrically before, during and after apheresis as well as in the plasma product. Furthermore, platelets, red and white blood cells were analysed as parameters of product quality. An average of 2751±247ml blood was processed in 47±6min. The collected plasma volume was 850±1mL and citrate consumption was 177±15mL. A continuous drop of donors' IgG level was observed during plasmapheresis. The drop was 13% of the IgG baseline value at 800mL collected plasma. Total protein, IgG and cell counts of the plasma product met current guidelines of plasma for fractionation. Donors' IgG levels during apheresis showed a steady decrease without compromising the quality of plasma product. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Capillary plasma jet: A low volume plasma source for life science applications

    Energy Technology Data Exchange (ETDEWEB)

    Topala, I., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Alexandru Ioan Cuza University of Iasi, Faculty of Physics, Iasi Plasma Advanced Research Center (IPARC), Bd. Carol I No. 11, Iasi 700506 (Romania); Nagatsu, M., E-mail: ionut.topala@uaic.ro, E-mail: tmnagat@ipc.shizuoka.ac.jp [Graduate School of Science and Technology, Shizuoka University, 3-5-1 Johoku, Naka-ku, Hamamatsu 432-8561 (Japan)

    2015-02-02

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  1. Capillary plasma jet: A low volume plasma source for life science applications

    Science.gov (United States)

    Topala, I.; Nagatsu, M.

    2015-02-01

    In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

  2. A large volume uniform plasma generator for the experiments of electromagnetic wave propagation in plasma

    International Nuclear Information System (INIS)

    Yang Min; Li Xiaoping; Xie Kai; Liu Donglin; Liu Yanming

    2013-01-01

    A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a “black out” phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm× 260 mm× 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.

  3. Potential formation in a collisionless plasma produced in an open magnetic field in presence of volume negative ion source

    International Nuclear Information System (INIS)

    Phukan, Ananya; Goswami, K. S.; Bhuyan, P. J.

    2014-01-01

    The electric potential near a wall for a multi-species plasma with volume produced negative ions in presence of axially varying magnetic field is studied following an analytical-numerical approach. A constant negative ion source is assumed throughout the plasma volume, along with finite temperature positive ions and Boltzmann electrons. The particles are assumed to be guided by an open magnetic field that has its maximum at the centre, and field strength decreasing towards the walls. The one dimensional (1D) Poisson equation is derived using an analytical approach, and then solved numerically to study the potential profiles. Effect of (a) negative ion production rate, (b) magnetic field profile, and (c) negative ion temperature on the potential profile has been investigated. A potential peak appears near the wall when the negative ion temperature and density are sufficiently high. Also, the presence of negative ions further decreases the potential in the plasma region for a finite Debye Length (λ D )

  4. Plasma and blood volume in the calf from birth till 90 days of age

    International Nuclear Information System (INIS)

    Moellerberg, L.; Ekman, L.; Jacobsson, S.-O.

    1975-01-01

    Determinations of plasma volume were made of 9 clinically healthy Swedish Red and White calves from birth to 90 days of age by means of the isotop dilution technique. Commercially available 131 I labelled human serum albumin was used. Calculation of the total blood volume was based on the plasma volume and packed cell volume. The plasma and blood volumes increased per kg body weight in average 17 and 14 percent respectively from directly after birth to 24 hrs. old. From 1 to 90 days of age the plasma and blood volume fell steadily per kg body weight. Plasma volume expressed as a percentage of body weight was 5.3 percent at birth, 6.5 percent at 1 day old, and 4.9 percent at 90 days old. Corresponding values for blood were 8.4, 9.3 and 7.0 percent. (author)

  5. Changes in plasma volume and baroreflex function following resistance exercise

    Science.gov (United States)

    Ploutz, L. L.; Tatro, D. L.; Dudley, G. A.; Convertino, V. A.

    1993-01-01

    The dynamics of change in plasma volume (PV) and baroreflex responses have been reported over 24 h immediately following maximal cycle exercise. The purpose of this study was to determine if PV and baroreflex showed similar changes for 24 h after resistance exercise. Eight men were studied on 2 test days, 1 week apart. On 1 day, per cent change (% delta) in PV was estimated at 0,3, and 6 h after resistance exercise using haematocrit and haemoglobin. Baseline PV was measured 24 h after exercise using Evans blue dye. The carotid baroreceptor-cardiac reflex response was measured before, and 3, 6, 9, 12, and 24 h post-exercise. Each subject performed six sets of the bench press and leg press with 10 repetitions per set with a load that induced failure within each set. On a control day, the protocol was used without exercise. Plasma volume did not change during the control day. There was a 20% decrease in PV immediately post-exercise; the recovery of the PV was rapid and complete within 3 h. PV was 20% greater 24 h post-exercise than on the control day. There were no differences in any of the baroreflex measurements. Therefore, it is suggested that PV shifts may occur without altering baroreflex sensitivity.

  6. Plasma response to electron energy filter in large volume plasma device

    International Nuclear Information System (INIS)

    Sanyasi, A. K.; Awasthi, L. M.; Mattoo, S. K.; Srivastava, P. K.; Singh, S. K.; Singh, R.; Kaw, P. K.

    2013-01-01

    An electron energy filter (EEF) is embedded in the Large Volume Plasma Device plasma for carrying out studies on excitation of plasma turbulence by a gradient in electron temperature (ETG) described in the paper of Mattoo et al. [S. K. Mattoo et al., Phys. Rev. Lett. 108, 255007 (2012)]. In this paper, we report results on the response of the plasma to the EEF. It is shown that inhomogeneity in the magnetic field of the EEF switches on several physical phenomena resulting in plasma regions with different characteristics, including a plasma region free from energetic electrons, suitable for the study of ETG turbulence. Specifically, we report that localized structures of plasma density, potential, electron temperature, and plasma turbulence are excited in the EEF plasma. It is shown that structures of electron temperature and potential are created due to energy dependence of the electron transport in the filter region. On the other hand, although structure of plasma density has origin in the particle transport but two distinct steps of the density structure emerge from dominance of collisionality in the source-EEF region and of the Bohm diffusion in the EEF-target region. It is argued and experimental evidence is provided for existence of drift like flute Rayleigh-Taylor in the EEF plasma

  7. 99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

    DEFF Research Database (Denmark)

    Bonfils, Peter K; Damgaard, Morten; Stokholm, Knud H

    2012-01-01

    OBJECTIVE: Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin ((99m)Tc-HSA) with a simultaneously performed plasma volume determination...... with iodine-labeled human serum albumin ((125)I-HSA). MATERIALS AND METHODS: In 15 healthy volunteers, simultaneous plasma volume measurements with (99m)Tc-HSA and (125)I-HSA were performed after ½ hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection...... for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. RESULTS: The mean difference (bias) between plasma volume measured with (125)I-albumin and (99m)Tc-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias ±1.96 SD) ranging from -181...

  8. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    Science.gov (United States)

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Prepregnancy low-plasma volume and predisposition to preeclampsia and fetal growth restriction

    NARCIS (Netherlands)

    Scholten, R.R.; Sep, S.; Peeters, L.; Hopman, M.T.E.; Lotgering, F.K.; Spaanderman, M.E.A.

    2011-01-01

    OBJECTIVE: To estimate whether recurrence risks of preeclampsia, preterm birth, and fetal growth restriction relate to prepregnancy plasma volume. METHODS: We conducted a retrospective cohort study in 580 formerly preeclamptic women and a control group. In all women we measured plasma volume

  10. The decrease of cardiac chamber volumes and output during positive-pressure ventilation

    DEFF Research Database (Denmark)

    Kristensen, Kasper Kyhl; Ahtarovski, Kiril Aleksov; Iversen, Kasper

    2013-01-01

    the effect of PPV on the central circulation by studying cardiac chamber volumes with cardiac magnetic resonance imaging (CMR). We hypothesized that PPV lowers cardiac output (CO) mainly via the Frank-Starling relationship. In 18 healthy volunteers, cardiac chamber volumes and flow in aorta and the pulmonary...... artery were measured by CMR during PPV levels of 0, 10, and 20 cmH2O applied via a respirator and a face mask. All cardiac chamber volumes decreased in proportion to the level of PPV. Following 20-cmH2O PPV, the total diastolic and systolic cardiac volumes (±SE) decreased from 605 (±29) ml to 446 (±29......) ml (P volume decreased by 27 (±4) ml/beat; heart rate increased by 7 (±2) beats/min; and CO decreased by 1.0 (±0.4) l/min (P

  11. Moderator's view: High-volume plasma exchange: pro, con and consensus.

    Science.gov (United States)

    Kaplan, Andre A

    2017-09-01

    I have been asked to comment on the pro and con opinions regarding high-volume plasma exchange. The authors of both positions have provided cogent arguments and a reasonable approach to choosing the exchange volume for any given therapeutic plasma exchange. The major issue of relevance in this discussion is the nature of the toxins targeted for removal. These parameters include molecular weight, the apparent volume of distribution, the degree of protein binding, the biologic and chemical half-life, and the severity and rapidity of its toxicity. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  12. Supplementation with Folic Acid, but Not Creatine, Increases Plasma Betaine, Decreases Plasma Dimethylglycine, and Prevents a Decrease in Plasma Choline in Arsenic-Exposed Bangladeshi Adults123

    Science.gov (United States)

    Hall, Megan N; Liu, Xinhua; Caudill, Marie A; Malysheva, Olga; Ilievski, Vesna; Lomax-Luu, Angela M; Parvez, Faruque; Siddique, Abu B; Shahriar, Hasan; Uddin, Mohammad N; Islam, Tariqul; Graziano, Joseph H; Gamble, Mary V

    2016-01-01

    Background: Folic acid (FA) supplementation facilitates urinary excretion of arsenic, a human carcinogen. A better understanding of interactions between one-carbon metabolism intermediates may improve the ability to design nutrition interventions that further facilitate arsenic excretion. Objective: The objective was to determine if FA and/or creatine supplementation increase choline and betaine and decrease dimethylglycine (DMG). Methods: We conducted a secondary analysis of the Folic Acid and Creatine Trial, a randomized trial in arsenic-exposed Bangladeshi adults (n = 605, aged 24–55 y, 50.3% male) who received arsenic-removal water filters. We examined treatment effects of FA and/or creatine supplementation on plasma choline, betaine, and DMG concentrations, measured by LC–tandem mass spectrometry at baseline and at week 12. Group comparisons were between 1) 400 and 800 μg FA/d (FA400 and FA800, respectively) compared with placebo, 2) creatine (3 g/d) compared with placebo, and 3) creatine plus FA400 compared with FA400. Results: Choline decreased in the placebo group (−6.6%; 95% CI: −10.2%, −2.9%) but did not change in the FA groups (FA400: 2.5%; 95% CI: −0.9%, 6.1%; FA800: 1.4%; 95% CI: −2.5%, 5.5%; P DMG was greater in the FA groups (FA400: −26.7%; 95% CI: −30.9%, −22.2%; FA800: −27.8%; 95% CI: −31.8%, −23.4%) than in the placebo group (−12.3%; 95% CI: −18.1%, −6.2%; P DMG did not differ between creatine treatment arms and their respective reference groups. Conclusion: Supplementation for 12 wk with FA, but not creatine, increases plasma betaine, decreases plasma DMG, and prevents a decrease in plasma choline in arsenic-exposed Bangladeshi adults. This trial was registered at clinicaltrials.gov as NCT01050556. PMID:27052531

  13. The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

    Science.gov (United States)

    Burton, R. R.; Smith, A. H.

    1972-01-01

    Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

  14. Plasma volume methodology: Evans blue, hemoglobin-hematocrit, and mass density transformations

    Science.gov (United States)

    Greenleaf, J. E.; Hinghofer-Szalkay, H.

    1985-01-01

    Methods for measuring absolute levels and changes in plasma volume are presented along with derivations of pertinent equations. Reduction in variability of the Evans blue dye dilution technique using chromatographic column purification suggests that the day-to-day variability in the plasma volume in humans is less than + or - 20 m1. Mass density determination using the mechanical-oscillator technique provides a method for measuring vascular fluid shifts continuously for assessing the density of the filtrate, and for quantifying movements of protein across microvascular walls. Equations for the calculation of volume and density of shifted fluid are presented.

  15. Decrease in plasma high-density lipoprotein cholesterol levels at puberty in boys with delayed adolescence: correlation with plasma testosterone levels

    International Nuclear Information System (INIS)

    Kirkland, R.T.; Keenan, B.S.; Probstfield, J.L.; Patsch, W.; Lin, T.L.; Clayton, G.W.; Insull, W. Jr.

    1987-01-01

    A three-phase study tested the hypothesis that the decrease in the high-density lipoprotein cholesterol (HDL-C) level observed in boys at puberty is related to an increase in the plasma testosterone concentration. In phase I, 57 boys aged 10 to 17 years were categorized into four pubertal stages based on clinical parameters and plasma testosterone levels. These four groups showed increasing plasma testosterone values and decreasing HDL-C levels. In phase II, 14 boys with delayed adolescence were treated with testosterone enanthate. Plasma testosterone levels during therapy were in the adult male range. Levels of HDL-C decreased by a mean of 7.4 mg/dL (0.20 mmol/L) and 13.7 mg/dL (0.35 mmol/L), respectively, after the first two doses. In phase III, 13 boys with delayed adolescence demonstrated increasing plasma testosterone levels and decreasing HDL-C levels during spontaneous puberty. Levels of HDL-C and apolipoprotein A-1 were correlated during induced and spontaneous puberty. Testosterone should be considered a significant determinant of plasma HDL-C levels during pubertal development

  16. Krill oil significantly decreases 2-arachidonoylglycerol plasma levels in obese subjects

    Directory of Open Access Journals (Sweden)

    Giordano Elena

    2011-01-01

    Full Text Available Abstract We have previously shown that krill oil (KO, more efficiently than fish oil, was able to downregulate the endocannabinoid system in different tissues of obese zucker rats. We therefore aimed at investigating whether an intake of 2 g/d of either KO or menhaden oil (MO, which provides 309 mg/d of EPA/DHA 2:1 and 390 mg/d of EPA/DHA 1:1 respectively, or olive oil (OO for four weeks, is able to modify plasma endocannabinoids in overweight and obese subjects. The results confirmed data in the literature describing increased levels of endocannabinoids in overweight and obese with respect to normo-weight subjects. KO, but not MO or OO, was able to significantly decrease 2-arachidonoylglycerol (2-AG, although only in obese subjects. In addition, the decrease of 2-AG was correlated to the plasma n-6/n-3 phospholipid long chain polyunsaturated fatty acid (LCPUFA ratio. These data show for the first time in humans that relatively low doses of LCPUFA n-3 as KO can significantly decrease plasma 2-AG levels in obese subjects in relation to decrease of plasma phospholipid n-6/n-3 LCPUFA ratio. This effect is not linked to changes of metabolic syndrome parameters but is most likely due to a decrease of 2-AG biosynthesis caused by the replacement of 2-AG ultimate precursor, arachidonic acid, with n-3 PUFAs, as previously described in obese Zucker rats.

  17. Vacuum heating evaluation for plasmas of exponentially decreasing density profile

    International Nuclear Information System (INIS)

    Pestehe, S.J.; Mohammadnejad, M.

    2008-01-01

    Ultra-short pulse lasers have opened a regime of laser-plasma interaction where plasmas have scale lengths shorter than the laser wavelength and allow the possibility of generating near-solid density plasmas. The interaction of high-intensity laser beams with sharply bounded high-density and small scale length plasmas is considered. Absorption of the laser energy associated with the mechanism of dragging electrons out of the plasma into the vacuum and sending them back into the plasma with the electric field component along the density gradient, so called vacuum heating, is studied. An exponentially decreasing electron density profile is assumed. The vector potential of the electromagnetic field propagating through the plasma is calculated and the behaviour of the electric and magnetic components of the electromagnetic field is studied. The fraction of laser power absorbed in this process is calculated and plotted versus the laser beam incidence angle, illumination energy, and the plasma scale length

  18. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  19. Glucose rapidly decreases plasma membrane GLUT4 content in rat skeletal muscle.

    Science.gov (United States)

    Marette, A; Dimitrakoudis, D; Shi, Q; Rodgers, C D; Klip, A; Vranic, M

    1999-02-01

    We have previously demonstrated that chronic hyperglycemia per se decreases GLUT4 glucose transporter expression and plasma membrane content in mildly streptozotocin- (STZ) diabetic rats (Biochem. J. 284, 341-348, 1992). In the present study, we investigated the effect of an acute rise in glycemia on muscle GLUT4 and GLUT1 protein contents in the plasma membrane, in the absence of insulin elevation. Four experimental groups of rats were analyzed in the postabsorptive state: 1. Control rats. 2. Hyperglycemic STZ-diabetic rats with moderately reduced fasting insulin levels. 3. STZ-diabetic rats made normoglycemic with phlorizin treatment. 4. Phlorizin-treated (normoglycemic) STZ-diabetic rats infused with glucose for 40 min. The uniqueness of the latter model is that glycemia can be rapidly raised without any concomitant increase in plasma insulin levels. Plasma membranes were isolated from hindlimb muscle and GLUT1 and GLUT4 proteins amounts determined by Western blot analysis. As predicted, STZ-diabetes caused a significant decrease in the abundance of GLUT4 in the isolated plasma membranes. Normalization of glycemia for 3 d with phlorizin treatment restored plasma membrane GLUT4 content in muscle of STZ-diabetic rats. A sudden rise in glycemia over a period of 40 min caused the GLUT4 levels in the plasma membrane fraction to decrease to those of nontreated STZ-diabetic rats. In contrast to the GLUT4 transporter, plasma membrane GLUT1 abundance was not changed by the acute glucose challenge. It is concluded that glucose can have regulatory effect by acutely reducing plasma membrane GLUT4 protein contents in rat skeletal muscle. We hypothesize that this glucose-induced downregulation of plasma membrane GLUT4 could represent a protective mechanism against excessive glucose uptake under hyperglycemic conditions accompanied by insulin resistance.

  20. Plasma klotho levels decrease in both anorexia nervosa and obesity.

    Science.gov (United States)

    Amitani, Marie; Asakawa, Akihiro; Amitani, Haruka; Kaimoto, Kaori; Sameshima, Nanami; Koyama, Ken Ichiro; Haruta, Izumi; Tsai, Minglun; Nakahara, Toshihiro; Ushikai, Miharu; Cheng, Kai-Chun; Hamada, Satoshi; Inui, Akio

    2013-09-01

    The aim of this study was to examine the associations of klotho with body mass index (BMI) in patients with restricting-type anorexia nervosa (r-AN) and obesity. We examined plasma klotho as well as adiponectin and its isoform levels in comparison in 11 obese patients, 12 r-AN patients, and 11 control participants. Plasma klotho levels were markedly lower in the obesity and r-AN groups than in the control group. Moreover, plasma klotho levels increased significantly after the recovery of BMI in r-AN patients. Total and high-molecular-weight adiponectin levels were significantly decreased only in obesity. There was no relationship between klotho and total adiponectin levels or klotho and respective adiponectin isoform levels in the entire study population. These results suggest that klotho may reflect normal nutritional state, and that the decrease of klotho in r-AN and obesity may underlie the deteriorating processes of these disorders. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. A model for steady-state large-volume plasma generation

    International Nuclear Information System (INIS)

    Uhm, H.S.; Miller, J.D.; Schneider, R.F.

    1991-01-01

    In this paper, a simple, new scheme to generate a uniform, steady-state, large-volume plasma is presented. The weakly magnetized plasma is created by direct ionization of the background gas by low-energy electrons generated from thermionic filaments. An annular arrangement of the filaments ensures a uniform plasma density in the radial direction as predicted by theory. Experiments have been performed to characterize the plasma generated in such a configuration. In order to explain the experimental observation, we develop a bulk plasma theory based on plasma transport via cross-field diffusion. As assumed in the theoretical model, the experimental measurements indicate a uniform plasma density along the axis. Both the theory and experiment indicate that the plasma density is a function of the square of the external magnetic field. The theory also predicts the plasma density to be proportional to the neutral density to the two-thirds power in agreement with the experimental data. We also observe the experimental data to agree remarkably well with theoretical prediction for a broad range of system parameters

  2. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    Science.gov (United States)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  3. Recovery of plasma volume after 1 week of exposure at 4,350 m

    DEFF Research Database (Denmark)

    Robach, Paul; Lafforgue, Eric; Olsen, Niels Vidiendal

    2002-01-01

    Plasma volume (PV) decreases at high altitude, but is rapidly restored upon return to sea-level (RSL). The aim of this study was (1) to describe PV recovery upon RSL with concomitant changes in major fluid regulating hormones, and (2) to test the hypothesis that PV recovery is promoted...... natriuretic factor (ANF) and arginine vasopressin (AVP) were measured at rest and during exercise. The subjects were divided into two groups 1 h before RSL, one group receiving PV expansion (475+/-219 ml) to ensure normovolemia (PVX, n=6), the others serving as controls (Control, n=4). PV decreased by 13...... groups, whereas water output dropped in RSL. PVX increased urine flow rate in RSL1 compared with subjects not given PVX. The present results suggest that PV recovery during early RSL is mainly due to a decreased diuresis, promoted at least in part by changes in fluid regulating hormones. However, neither...

  4. Improved the accuracy of 99mTc-MAG3 plasma clearance method. The problem of the calculated plasma volume and its modification

    International Nuclear Information System (INIS)

    Watanabe, Nami; Komatani, Akio; Yamaguchi, Koichi; Takahashi, Kazuei

    1998-01-01

    The 99m Tc-MAG 3 plasma clearance method (MPC method), reported by Oriuchi et al., is a simple and useful count-based gamma camera method for calculating the 99m Tc-MAG 3 plasma clearance (CL MAG ). However, a discrepancy of CL MAG calculated by MPC method (MPC-CL MAG ) from the tubular extraction rate (TER) calculated by Russell's single-sample clearance determination (Russell-TER) was noted. The calculated plasma volume is assumed to be the cause. Since the plasma volume is reported to have a linear correlation with body surface area, Dissmann's formula was applied to calculate the plasma volume. Then Dissmann's formula was replaced by Ogawa's formula in the MPC method, and the procedure was then called the modified MPC method. The CL MAG were obtained using MPC method, modified MPC method and the TER was obtained Russell's method in 95 patients with urological disorders. Then the MPC-CL MAG and modified MPC-CL MAG were compared with Russell-TER. Comparison of the MPC-CL MAG with the Russell-TER demonstrated a coefficient of correlation of 0.82, but dissociation of the slope of regression lines was found between males and females. The modified MPC-CL MAG improved the coefficient of correlation to 0.92, and diminished the dissociation of the slope of regression lines between males and females. We verified that the dissociation was due to the plasma volume calculated by Ogawa's formula. Ogawa's formula included hematocrit, body weight, body height and different coefficients for gender. The plasma volume calculated by Ogawa's formula were lower in males and higher in females than that calculated by Dissmann's formula. And marked discrepancy in the plasma volume in patients with a body surface area below 0.5 m 2 was observed. So the MPC method might become more accurate by substituting Dissmann's formula for Ogawa's formula resoluting in a method that is applicable to both males and females, children and adults in clinical use. (author)

  5. Low plasma volume coincides with sympathetic hyperactivity and reduced baroreflex sensitivity in formerly preeclamptic patients.

    NARCIS (Netherlands)

    Courtar, D.A.; Spaanderman, M.E.A.; Aardenburg, R.; Janssen, B.J.; Peeters, L.L.

    2006-01-01

    BACKGROUND: Preeclampsia is associated with enhanced sympathetic activity as well as subnormal plasma volume. Meanwhile, in over 50% of these complicated pregnancies, the subnormal plasma volume has been found to persist for a prolonged period after pregnancy. The objective of this study is to test

  6. A uniform laminar air plasma plume with large volume excited by an alternating current voltage

    Science.gov (United States)

    Li, Xuechen; Bao, Wenting; Chu, Jingdi; Zhang, Panpan; Jia, Pengying

    2015-12-01

    Using a plasma jet composed of two needle electrodes, a laminar plasma plume with large volume is generated in air through an alternating current voltage excitation. Based on high-speed photography, a train of filaments is observed to propagate periodically away from their birth place along the gas flow. The laminar plume is in fact a temporal superposition of the arched filament train. The filament consists of a negative glow near the real time cathode, a positive column near the real time anode, and a Faraday dark space between them. It has been found that the propagation velocity of the filament increases with increasing the gas flow rate. Furthermore, the filament lifetime tends to follow a normal distribution (Gaussian distribution). The most probable lifetime decreases with increasing the gas flow rate or decreasing the averaged peak voltage. Results also indicate that the real time peak current decreases and the real time peak voltage increases with the propagation of the filament along the gas flow. The voltage-current curve indicates that, in every discharge cycle, the filament evolves from a Townsend discharge to a glow one and then the discharge quenches. Characteristic regions including a negative glow, a Faraday dark space, and a positive column can be discerned from the discharge filament. Furthermore, the plasma parameters such as the electron density, the vibrational temperature and the gas temperature are investigated based on the optical spectrum emitted from the laminar plume.

  7. Effect of catecholamines and insulin on plasma volume and intravascular mass of albumin in man

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1989-01-01

    1. The effect of intravenous catecholamine infusions and of intravenous insulin on plasma volume and intravascular mass of albumin was investigated in healthy males. 2. Physiological doses of adrenaline (0.5 microgram/min and 3 microgram/min) increased peripheral venous packed cell volume...... significantly; intravenous noradrenaline at 0.5 microgram/min had no effect on packed cell volume, whereas packed cell volume increased significantly at 3 micrograms of noradrenaline/min. No significant change in packed cell volume was found during saline infusion. 3. During adrenaline infusion at 6 micrograms...... in packed cell volume, plasma volume, intravascular mass of albumin and transcapillary escape rate of albumin during hypoglycaemia may be explained by the combined actions of adrenaline and insulin....

  8. Effect of Rehydration Fluid Osmolality on Plasma Volume and Vasopressin in Resting Dehydrated Men

    Science.gov (United States)

    Geelen, Ghislaine; Greenleaf, J. E.; Keil, L. C.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    Elevated plasma vasopressin concentration [PVP], which may act as a dipsogen, decreases promptly following the ingestion of fluids in many mammals including humans. The purpose for this study was to determine whether fluids of varied electrolyte and carbohydrate composition and osmolality (Osm] would modify post-drinking decreases in [PVP] which could be attributed to interaction with plasma volume (PV)- or fluid-electrolyte interactive hormones. Five men (23-41 yr, 78.0 +/- SD 8.2 kg), water deprived for 24 h, drank six fluids (12 ml/kg, at 16.5C in 4.0-6.2 min): water (30 m0sm/kg), NaCl (70 mOsm/kg), NaCl + NaCitrate (270 mOsm/kg), NaCl + 9.7% glucose (650 mOsm/kg), and two commercial drinks containing various ionic and carbohydrate contents (380 and 390 mOsm/kg). Blood (20 ml/sample) was drawn at -5 min before and at +3, +9, +15, +30, and +70 min after drinking. Heart rate, blood pressures, and plasma renin activity, {Na+], [K+], [Osm], aldosterone, atrial natriuretic peptide, and epinephrine concentrations were unchanged after drinking. Post-drinking [PVP] decreased from 1.7 - 3.7 pg/ml within 3 min with all fluids independently of their composition, [Osm], or delta PV; with maximal depression to 0.1-0.7 pg/ml (p<0.05) by 15 min. The continued [PVP] depression with all fluids from 15 to 70 min was accompanied by unchanged plasma (Osm] but 1.8-7.6% increases (p<0.05) in PV with 3) fluids (2 commercial and NaCitrate) and no change with the others. Percent changes in mean [PVP] and plasma norepinephrine concentrations [PNE] at 15 min correlated -0.70 (P<0.10) suggesting that about half the variability in [PVP I I depression was associated with [PNE]. Thus, part of the mechanism for post-drinking [PVP] depression may involve a drinking stimulated norepinephrine (neural) factor.

  9. The Effect of Ramadan Fasting and Weight-Lifting Training on Plasma Volume, Glucose and Lipids Profile of Male Weight-Lifters

    Directory of Open Access Journals (Sweden)

    Seyed Morteza Tayebi

    Full Text Available Objective(sThe purpose of the present study was to evaluate the effect of Ramadan fasting and weight-lifting training on plasma volume, glucose, and lipids profile of male weight-lifter.Materials and MethodsForty male weight-lifters were recruited and divided into 4 groups (n=10 each and as the following groups: control (C, fasting (F, training (T and fasting-training (F-T. The T and F-T groups performed weight-lifting technique trainings and hypertrophy body building (3 sessions/week, 90 min/session. All subjects were asked to complete a medical examination as well as a medical questionnaire to ensure that they were not taking any medication, were free of cardiac, respiratory, renal, and metabolic diseases, and were not using steroids. Blood samples were taken at 24 hr before and 24 hr after one month of fasting and weight-lifting exercise. The plasma volume, fasting blood sugar (FBS, lipid profiles, and lipoproteins were analyzed in blood samples. ResultsBody weight and plasma volume showed significant (P< 0.05 decrease and increase in the F group (P< 0.05 respectively. Also, a significant reduction was observed in F-T group body weight (P< 0.01. A significant increase was found in FBS level of F group (P< 0.05. The lipid profiles and lipoproteins didn’t change significantly in C, F, T and the F-T groups.ConclusionThe effect of Ramadan fasting on body weight and plasma volumes may be closely related to the nutritional diet or biochemical response to fasting.

  10. Blood and plasma volumes in normal west African dwarf sheep ...

    African Journals Online (AJOL)

    Blood and plasma volumes were determined using T-1824 in 36 normal adult West African Dwarf sheep. In the rams, dry ewes, pregnant ewes and lactating ewes, the mean values for the blood volume (ml/kg body weight) were 64.08 ± 6.11, 55.74 ± 9.31, 71.46 ± 6.46 and 147.12 ± 12.79 respectively, while the mean values ...

  11. Transport of high fluxes of hydrogen plasma in a linear plasma generator

    NARCIS (Netherlands)

    Vijvers, W.A.J.; Al, R.S.; Lopes Cardozo, N.J.; Goedheer, W.J.; Groot, de B.; Kleyn, A.W.; Meiden, van der H.J.; Peppel, van de R.J.E.; Schram, D.C.; Shumack, A.E.; Westerhout, J.; Rooij, van G.J.; Schmidt, J.; Simek, M.; Pekarek, S.; Prukner, V.

    2007-01-01

    A study was made to quantify the losses during the convective hydrogen plasma transport in the linear plasma generator Pilot-PSI due to volume recombination. A transport efficiency of 35% was achieved at neutral background pressures below ~7 Pa in a magnetic field of 1.2 T. This efficiency decreased

  12. Plasma uric acid and tumor volume are highly predictive of outcome in nasopharyngeal carcinoma patients receiving intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Lin, Hui; Lin, Huan-Xin; Ge, Nan; Wang, Hong-Zhi; Sun, Rui; Hu, Wei-Han

    2013-01-01

    The combined predictive value of plasma uric acid and primary tumor volume in nasopharyngeal carcinoma (NPC) patients receiving intensity modulated radiation therapy (IMRT) has not yet been determined. In this retrospective study, plasma uric acid level was measured after treatment in 130 histologically-proven NPC patients treated with IMRT. Tumor volume was calculated from treatment planning CT scans. Overall (OS), progression-free (PFS) and distant metastasis-free (DMFS) survival were compared using Kaplan-Meier analysis and the log rank test, and Cox multivariate and univariate regression models were created. Patients with a small tumor volume (<27 mL) had a significantly better DMFS, PFS and OS than patients with a large tumor volume. Patients with a high post-treatment plasma uric acid level (>301 μmol/L) had a better DMFS, PFS and OS than patients with a low post-treatment plasma uric acid level. Patients with a small tumor volume and high post-treatment plasma uric acid level had a favorable prognosis compared to patients with a large tumor volume and low post-treatment plasma uric acid level (7-year overall OS, 100% vs. 48.7%, P <0.001 and PFS, 100% vs. 69.5%, P <0.001). Post-treatment plasma uric acid level and pre-treatment tumor volume have predictive value for outcome in NPC patients receiving IMRT. NPC patients with a large tumor volume and low post-treatment plasma uric acid level may benefit from additional aggressive treatment after IMRT

  13. Long-term results of preventive embolization of renal angiomyolipomas: evaluation of predictive factors of volume decrease

    Energy Technology Data Exchange (ETDEWEB)

    Hocquelet, A.; Cornelis, F.; Le Bras, Y.; Meyer, M.; Tricaud, E.; Lasserre, A.S.; Grenier, N. [Centre Hospitalier Universitaire Pellegrin, Diagnostic and Therapeutic Urology and Vascular Imaging, Bordeaux (France); Ferriere, J.M.; Robert, G. [Centre Hospitalier Universitaire Pellegrin, Urology Service, Bordeaux (France)

    2014-08-15

    To evaluate the efficacy of selective arterial embolization (SAE) of angiomyolipomas based on the percentage volume reduction after embolization and to identify predictive factors of volume decrease. Patients receiving prophylactic SAE of renal angiomyolipomas were included retrospectively over 3 years. The volume change after SAE and haemorrhagic or surgical events were recorded. Initial tumour volume, percentage tumour fat content, mean tumour density, embolic agent used, number of angiomyolipomas and tuberous sclerosis disease were evaluated as predictive factors of volume decrease. A total of 19 patients with 39 angiomyolipomas were included with median follow-up of 28 months (interquartile range 21-37 months). All treatments were technically successful (92 % primary and 8 % secondary). No distal bleeding or any increase in size or surgical nephrectomy after SAE was recorded. Mean volume reduction was 72 % (±24 %). Volumes before SAE (R{sup 2} = 0.276; p = 0.001), percentage fat content (R{sup 2} = 0.612; p < 0.0001) and mean angiomyolipoma density (R{sup 2} = 0.536; p < 0.0001) were identified as predictive factors of volume decrease. In multivariate regression, only percentage fat content influenced volume decreases. SAE is an efficient treatment for angiomyolipoma devascularisation and volume reduction. A significant reduction of volume is modulated by the initial volume and tissue composition of the tumour. (orig.)

  14. Inductively coupled plasma emission spectroscopy. Part II: applications and fundamentals. Volume 2

    International Nuclear Information System (INIS)

    Boumans, P.W.J.M.

    1987-01-01

    This is the second part of the two-volume treatise by this well-known and respected author. This volume reviews applications of inductively coupled plasma atomic emission spectroscopy (ICP-AES), summarizes fundamental studies, and compares ICP-AES methods with other methods of analysis. The first six chapters are devoted to specific fields of application, including the following: metals and other industrial materials, geology, the environment, agriculture and food, biology and clinical analysis, and organic materials. The chapter on the analysis of organic materials also covers the special instrumental considerations required when organic solvents are introduced into an inductively coupled plasma. A chapter on the direct analysis of solids completes the first part of this volume. Each of the applications chapters begins with a summary of the types of samples that are encountered in that field, and the kinds of problems that an elemental analysis can help to solve. This is followed by a tutorial approach covering applicability, advantages, and limitations of the methods. The coverage is thorough, including sample handling, storage, and preparation, acid, and fusion dissolution, avoiding contamination, methods of preconcentration, the types of interferences that can be expected and ways to reduce them, and the types of ICP plasmas that are used. The second half of the volume covers fundamental studies of ICP-AES: basic processes of aerosol generation, plasma modeling and computer simulation, spectroscopic diagnostics, excitation mechanisms, and discharge characteristics. This section introduces the experimental and modeling methods that have been used to obtain fundamental information about ICPs

  15. Cardiac adaptation to pregnancy in women with a history of preeclampsia and a subnormal plasma volume.

    NARCIS (Netherlands)

    Andrietti, S.; Kruse, A.J.; Bekkers, S.C.; Sep, S.; Spaanderman, M.E.A.; Peeters, L.L.

    2008-01-01

    In former preeclamptics, a subnormal plasma volume (LPV) predisposes to hemodynamic maladaptation to pregnancy. Here, we assessed the initial cardiovascular response to pregnancy in LPV (n = 20), in former preeclamptics with normal plasma volume (NPV) (n = 35) and in parous controls (CONTR) (n = 9)

  16. Broadband frequency ECR ion source concepts with large resonant plasma volumes

    International Nuclear Information System (INIS)

    Alton, G.D.

    1995-01-01

    New techniques are proposed for enhancing the performances of ECR ion sources. The techniques are based on the use of high-power, variable-frequency, multiple-discrete-frequency, or broadband microwave radiation, derived from standard TWT technology, to effect large resonant ''volume'' ECR sources. The creation of a large ECR plasma ''volume'' permits coupling of more power into the plasma, resulting in the heating of a much larger electron population to higher energies, the effect of which is to produce higher charge state distributions and much higher intensities within a particular charge state than possible in present forms of the ECR ion source. If successful, these developments could significantly impact future accelerator designs and accelerator-based, heavy-ion-research programs by providing multiply-charged ion beams with the energies and intensities required for nuclear physics research from existing ECR ion sources. The methods described in this article can be used to retrofit any ECR ion source predicated on B-minimum plasma confinement techniques

  17. Quasilinear dynamics of a cloud of hot electrons propagating through a plasma with decreasing density and temperature

    International Nuclear Information System (INIS)

    Foroutan, G.; Khalilpour, H.; Moslehi-Fard, M.; Li, B.; Robinson, P. A.

    2008-01-01

    The effects of plasma inhomogeneities on the propagation of a cloud of hot electrons through a cold background plasma and generation of Langmuir waves are investigated using numerical simulations of the quasilinear equations. It is found that in a plasma with decreasing density the quasilinear relaxation of the electron distribution in velocity space is accelerated and the levels of the generated Langmuir waves are enhanced. The magnitude of the induced emission rate is increased and its maximum value moves to lower velocities. Due to density gradient the height of plateau shows an increase at small distances and a corresponding decrease at large distances. It is also found that in a plasma with decreasing temperature, the relaxation of the beam is retarded, the spectral density of Langmuir waves is broadened, and the height of the plateau decreases below its value in a uniform plasma. In the presence of both density and temperature gradients, at given position, the height and upper boundary of the plateau and the level of Langmuir waves are all increased at small velocities. The spatial expansion of the beam is increased by the plasma inhomogeneities, but its average velocity of propagation decreases. Initially, at a given position, the velocity at the upper boundary of the plateau is smaller in the presence of the density gradient than in the uniform plasma but the reverse is true at longer times. Due to temperature gradient, at large times and small distances, the upper boundary of the plateau is increased above its value in the uniform plasma. Because of fast relaxation, the value of the lower boundary of the plateau in the plasma with decreasing density is always less than its value in the uniform plasma. It is found that the local velocity of the beam decreases when the density gradient is present. The local velocity spread of the beam remains unchanged during the propagation of the beam in the uniform plasma, but increases in the presence of inhomogeneities.

  18. Plasma surface modification of rigid contact lenses decreases bacterial adhesion.

    Science.gov (United States)

    Wang, Yingming; Qian, Xuefeng; Zhang, Xiaofeng; Xia, Wei; Zhong, Lei; Sun, Zhengtai; Xia, Jing

    2013-11-01

    Contact lens safety is an important topic in clinical studies. Corneal infections usually occur because of the use of bacteria-carrying contact lenses. The current study investigated the impact of plasma surface modification on bacterial adherence to rigid contact lenses made of fluorosilicone acrylate materials. Boston XO and XO2 contact lenses were modified using plasma technology (XO-P and XO2-P groups). Untreated lenses were used as controls. Plasma-treated and control lenses were incubated in solutions containing Staphylococcus aureus or Pseudomonas aeruginosa. MTT colorimetry, colony-forming unit counting method, and scanning electron microscopy were used to measure bacterial adhesion. MTT colorimetry measurements showed that the optical density (OD) values of XO-P and XO2-P were significantly lower than those of XO and XO2, respectively, after incubation with S. aureus (P lenses and to the XO2-P versus XO2 lenses incubated with S. aureus (P lenses incubated with P. aeruginosa (P lenses. Plasma surface modification can significantly decrease bacterial adhesion to fluorosilicone acrylate contact lenses. This study provides important evidence of a unique benefit of plasma technology in contact lens surface modification.

  19. Plasma volume expansion does not increase maximal cardiac output or VO2 max in lowlanders acclimatized to altitude

    DEFF Research Database (Denmark)

    Calbet, José A L; Rådegran, Göran; Boushel, Robert Christopher

    2004-01-01

    liter of 6% dextran 70 (BV = 6.32 +/- 0.34 liters). PV expansion had no effect on Qmax, maximal O2 consumption (VO2), and exercise capacity. Despite maximal systemic O2 transport being reduced 19% due to hemodilution after PV expansion, whole body VO2 was maintained by greater systemic O2 extraction (P...... VO2 during exercise regardless of PV. Pulmonary ventilation, gas exchange, and acid-base balance were essentially unaffected by PV expansion. Sea......With altitude acclimatization, blood hemoglobin concentration increases while plasma volume (PV) and maximal cardiac output (Qmax) decrease. This investigation aimed to determine whether reduction of Qmax at altitude is due to low circulating blood volume (BV). Eight Danish lowlanders (3 females, 5...

  20. Convective plasma stability consistent with MHD equilibrium in magnetic confinement systems with a decreasing field

    International Nuclear Information System (INIS)

    Tsventoukh, M. M.

    2010-01-01

    A study is made of the convective (interchange, or flute) plasma stability consistent with equilibrium in magnetic confinement systems with a magnetic field decreasing outward and large curvature of magnetic field lines. Algorithms are developed which calculate convective plasma stability from the Kruskal-Oberman kinetic criterion and in which the convective stability is iteratively consistent with MHD equilibrium for a given pressure and a given type of anisotropy in actual magnetic geometry. Vacuum and equilibrium convectively stable configurations in systems with a decreasing, highly curved magnetic field are calculated. It is shown that, in convectively stable equilibrium, the possibility of achieving high plasma pressures in the central region is restricted either by the expansion of the separatrix (when there are large regions of a weak magnetic field) or by the filamentation of the gradient plasma current (when there are small regions of a weak magnetic field, in which case the pressure drops mainly near the separatrix). It is found that, from the standpoint of equilibrium and of the onset of nonpotential ballooning modes, a kinetic description of convective stability yields better plasma confinement parameters in systems with a decreasing, highly curved magnetic field than a simpler MHD model and makes it possible to substantially improve the confinement parameters for a given type of anisotropy. For the Magnetor experimental compact device, the maximum central pressure consistent with equilibrium and stability is calculated to be as high as β ∼ 30%. It is shown that, for the anisotropy of the distribution function that is typical of a background ECR plasma, the limiting pressure gradient is about two times steeper than that for an isotropic plasma. From a practical point of view, the possibility is demonstrated of achieving better confinement parameters of a hot collisionless plasma in systems with a decreasing, highly curved magnetic field than those

  1. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  2. Role of decreased Plasma Tryptophan in memory deficits observed in Type-I diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, S.; Tabassum, S.; Haider, S. [University of Karachi (Pakistan). Dept. of Biochemistry

    2013-01-15

    Objective: To investigate the relationship between plasma tryptophan and the occurrence of memory dysfunctions in male and female type 1 diabetics. Methods: The case-control study was conducted at two urban healthcare facilities in Karachi from January to June 2009, and comprised 100 diabetic subjects of among whom were 50 men and 50 women. The controls were also similar in number and gender. A questionnaire was used to evaluate the memory impairment in the subjects. Plasma tryptophan was determined by high performance liquid chromatography with ultra-violet method. Students t-test was used to analyse tryptophan data. Results: There was considerable memory impairment in the cases (n=40) compared to the controls (n=5). Results also showed a significant (p<0.01) decrease in plasma tryptophan levels in both male and female diabetic patients. Conclusions: Diabetic subjects exhibited occurrence of memory impairment with concomitant decline in plasma tryptophan levels. The findings indicate that decreased brain uptake of tryptophan and lowered brain 5-hydroxytryptamine levels may be responsible for the memory deficits seen in diabetics. (author)

  3. Role of decreased Plasma Tryptophan in memory deficits observed in Type-I diabetes

    International Nuclear Information System (INIS)

    Ahmad, S.; Tabassum, S.; Haider, S.

    2013-01-01

    Objective: To investigate the relationship between plasma tryptophan and the occurrence of memory dysfunctions in male and female type 1 diabetics. Methods: The case-control study was conducted at two urban healthcare facilities in Karachi from January to June 2009, and comprised 100 diabetic subjects of among whom were 50 men and 50 women. The controls were also similar in number and gender. A questionnaire was used to evaluate the memory impairment in the subjects. Plasma tryptophan was determined by high performance liquid chromatography with ultra-violet method. Students t-test was used to analyse tryptophan data. Results: There was considerable memory impairment in the cases (n=40) compared to the controls (n=5). Results also showed a significant (p<0.01) decrease in plasma tryptophan levels in both male and female diabetic patients. Conclusions: Diabetic subjects exhibited occurrence of memory impairment with concomitant decline in plasma tryptophan levels. The findings indicate that decreased brain uptake of tryptophan and lowered brain 5-hydroxytryptamine levels may be responsible for the memory deficits seen in diabetics. (author)

  4. Carbogen Breathing Differentially Enhances Blood Plasma Volume and 5-Fluorouracil Uptake in Two Murine Colon Tumor Models with a Distinct Vascular Structure

    Directory of Open Access Journals (Sweden)

    Hanneke W.M. van Laarhoven

    2006-06-01

    Full Text Available For the systemic treatment of colorectal cancer, 5-fluorouracil (FU-based chemotherapy is the standard. However, only a subset of patients responds to chemotherapy. Breathing of carbogen (95% O2 and 5% CO2 may increase the uptake of FU through changes in tumor physiology. This study aims to monitor in animal models in vivo the effects of carbogen breathing on tumor blood plasma volume, pH, and energy status, and on FU uptake and metabolism in two colon tumor models C38 and C26a, which differ in their vascular structure and hypoxic status. Phosphorus-31 magnetic resonance spectroscopy (MRS was used to assess tumor pH and energy status, and fluorine-19 MRS was used to follow FU uptake and metabolism. Advanced magnetic resonance imaging methods using ultrasmall particles of iron oxide were performed to assess blood plasma volume. The results showed that carbogen breathing significantly decreased extracellular pH and increased tumor blood plasma volume and FU uptake in tumors. These effects were most significant in the C38 tumor line, which has the largest relative vascular area. In the C26a tumor line, carbogen breathing increased tumor growth delay by FU. In this study, carbogen breathing also enhanced systemic toxicity by FU.

  5. Exposure to DEHP decreased four fatty acid levels in plasma of prepartum mice

    International Nuclear Information System (INIS)

    Nakashima, Ryosuke; Hayashi, Yumi; Khalequzzaman, Md.; Jia, Xiaofang; Wang, Dong; Naito, Hisao; Ito, Yuki; Kamijima, Michihiro; Gonzalez, Frank J.; Nakajima, Tamie

    2013-01-01

    Maternal exposure to di(2-ethylhexyl) phthalate (DEHP) decreased the plasma triglyceride in prepartum mice. To identify the fatty acid (FA) species involved and to understand the underlying mechanisms, pregnant Sv/129 wild-type (mPPARα), peroxisome proliferator-activated receptor α-null (Pparα-null) and humanized PPARα (hPPARα) mice were treated with diets containing 0%, 0.01%, 0.05% or 0.1% DEHP. Dams were dissected on gestational day 18 together with fetuses, and on postnatal day 2 together with newborns. n-3/n-6 polyunsaturated, saturated, and monounsaturated FAs in maternal plasma and in liver of wild-type offspring, and representative enzymes for FA desaturation and elongation in maternal liver, were measured. The plasma levels of linoleic acid, α-linolenic acid, palmitic acid and oleic acid were higher in the pregnant control mPPARa mice than in Ppara-null and hPPARa mice. DEHP exposure significantly decreased the levels of these four FAs only in pregnant mPPARα mice. Plasma levels of many FAs were higher in pregnant mice than in postpartum ones in a genotype-independent manner, while it was lower in the livers of fetuses than pups. DEHP exposure slightly increased hepatic arachidonic acid, α-linolenic acid, palmitoleic acid and oleic acid in fetuses, but not in pups. However, DEHP exposure did not clearly influence FA desaturase 1 and 2 nor elongase 2 and 5 expressions in the liver of all maternal mice. Taken together, the levels of plasma four FAs with shorter carbon chains were higher in pregnant mPPARα mice than in other genotypes, and DEHP exposure decreased these specific FA concentrations only in mPPARα mice, similarly to triglyceride levels

  6. Epidural anesthesia, hypotension, and changes in intravascular volume

    DEFF Research Database (Denmark)

    Holte, Kathrine; Foss, Nicolai B; Svensén, Christer

    2004-01-01

    receiving hydroxyethyl starch. RESULTS: Plasma volume did not change per se after thoracic epidural anesthesia despite a decrease in blood pressure. Plasma volume increased with fluid administration but remained unchanged with vasopressors despite that both treatments had similar hemodynamic effects...... constant was 56 ml/min. CONCLUSIONS: Thoracic epidural anesthesia per se does not lead to changes in blood volumes despite a reduction in blood pressure. When fluid is infused, there is a dilution, and the fluid initially seems to be located centrally. Because administration of hydroxyethyl starch......BACKGROUND: The most common side effect of epidural or spinal anesthesia is hypotension with functional hypovolemia prompting fluid infusions or administration of vasopressors. Short-term studies (20 min) in patients undergoing lumbar epidural anesthesia suggest that plasma volume may increase when...

  7. Predicted Hematologic and Plasma Volume Responses Following Rapid Ascent to Progressive Altitudes

    Science.gov (United States)

    2014-06-01

    Detection of unethical and illegal manipulation of erythrocyte volume by following changes in hemoglobin concentration ([Hb]) in elite athletes is a...tolerance to environmental extremes [2,3] and such manipulation often results in acute plasma volume (PV) loss and elevated hemoglobin concentrations [3...bodies to detect "unfair practices" in athletes seeking to gain an edge in their performance through illegal manipulation of their erythrocyte

  8. [Effects of dietary wheat gluten level on decreasing plasma homocysteine concentration in rats].

    Science.gov (United States)

    Liu, Yiqun; Han, Feng; Sun, Licui; Lu, Jiaxi; Sugiyama, Kimio; Huang, Zhenwu

    2015-05-01

    To investigate the effects of different level of casein and wheat gluten on decreasing plasma homocysteine concentration in rats. 48 rats of the Wistar were fed with different level of casein (12.5%, 25% and 50%) and wheat gluten (14.5%, 29% and 58%) diets for 14 days, and they were killed by decapitation to obtain blood and livers was subject to analysis the concentration of homocysteine, cysteine and other amino acids, as well as BHMT and CBS activities. Body weight gain in rats fed wheat gluten dietary was significantly less than casein dietary, but food intake was significantly decreased in wheat gluten group with increasing of the protein content. The plasma homocysteine concentration in rats fed wheat gluten was marketly less than casein, however plasma cysteine concentration in wheat gluten was higher than casein group. The effects of wheat gluten on plasma homocysteine concentration are mainly depends on the low contents of methionine and high cysteine content, but the low contents of lyscine and threonine are not ignored. The mainly mechanism is that the increased cysteine concentration promot enzyme activities of homocystein metabolism, and increase the consumption of homocysteine.

  9. Blood volume studies in chronic renal failure using radioactive 51Cr

    International Nuclear Information System (INIS)

    Chadda, V.S.; Mehta, S.R.; Mathur, D.

    1975-01-01

    Estimation of blood volume was carried out in 20 healthy subjects and in 25 patients suffering from chronic renal failure using radioactive 51 Cr. A detailed history, physical examination and investigations were also undertaken. On statistical evaluation, the red cell volume was diminished significantly in males and females but rise in blood volume was insignificant. Plasma volume was raised significantly in females but was insignificant in males. The reduction in red cell volume is due to reduced red cell mass because of chronic renal disease. Plasma volume may be elevated in order to compensate for decreased red cell volume. The variability in these two parameters results in variable blood volume. (author)

  10. Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Brandenburg, Sytze [KVI Center for Advanced Radiation Research, University of Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Coppes, Robert P. [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Luijk, Peter van, E-mail: p.van.luijk@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2016-01-01

    Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed the dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late

  11. Impact of diuretic treatment and sodium intake on plasma volume in patients with compensated systolic heart failure

    DEFF Research Database (Denmark)

    Bonfils, Peter K; Damgaard, Morten; Taskiran, Mustafa

    2010-01-01

    AIMS: In patients with heart failure (HF), the use of diuretics may be a double-edged sword that can alleviate symptoms of congestion, but also result in over-diuresis and intravascular volume depletion. The purpose of the present study was to examine plasma volume (PV) in HF patients receiving...... difference in PV between patients with HF and control subjects (37.3 +/- 6.0 and 40.2 +/- 5.8 mL/kg, respectively, P = 0.092) with a significant tendency towards a contraction of PV with increasing use of diuretics (P = 0.031). There was no difference in extracellular volume between patients with HF...... and control subjects (P = 0.844). NT-proBNP plasma concentrations had no correlation to either sodium excretion (P = 0.193) or PV (P = 0.471) in patients with HF. CONCLUSION: Plasma volume in patients with HF was within normal limits, but patients treated with high doses of loop-diuretics tended to have...

  12. Decrease of Plasma Glucose by Hibiscus taiwanensis in Type-1-Like Diabetic Rats

    Science.gov (United States)

    Wang, Lin-Yu; Chung, Hsien-Hui

    2013-01-01

    Hibiscus taiwanensis (Malvaceae) is widely used as an alternative herb to treat disorders in Taiwan. In the present study, it is used to screen the effect on diabetic hyperglycemia in streptozotocin-induced diabetic rats (STZ-diabetic rats). The extract of Hibiscus taiwanensis showed a significant plasma glucose-lowering action in STZ-diabetic rats. Stems of Hibiscus taiwanensis are more effective than other parts to decrease the plasma glucose in a dose-dependent manner. Oral administration of Hibiscus taiwanensis three times daily for 3 days into STZ-diabetic rats increased the sensitivity to exogenous insulin showing an increase in insulin sensitivity. Moreover, similar repeated administration of Hibiscus taiwanensis for 3 days in STZ-diabetic rats produced a marked reduction of phosphoenolpyruvate carboxykinase (PEPCK) expression in liver and an increased expression of glucose transporter subtype 4 (GLUT 4) in skeletal muscle. Taken together, our results suggest that Hibiscus taiwanensis has the ability to lower plasma glucose through an increase in glucose utilization via elevation of skeletal GLUT 4 and decrease of hepatic PEPCK in STZ-diabetic rats. PMID:23690841

  13. Altitude Acclimatization and Blood Volume: Effects of Exogenous Erythrocyte Volume Expansion

    National Research Council Canada - National Science Library

    Sawka, M

    1996-01-01

    ...: (a) altitude acclimatization effects on erythrocyte volume and plasma volume; (b) if exogenous erythrocyte volume expansion alters subsequent erythrocyte volume and plasma volume adaptations; (c...

  14. Decreased Left Putamen and Thalamus Volume Correlates with Delusions in First-Episode Schizophrenia Patients

    Directory of Open Access Journals (Sweden)

    Xiaojun Huang

    2017-11-01

    Full Text Available BackgroundDelusional thinking is one of the hallmark symptoms of schizophrenia. However, the underlying neural substrate for delusions in schizophrenia remains unknown. In an attempt to further our understanding of the neural basis of delusions, we explored gray matter deficits and their clinical associations in first-episode schizophrenia patients with and without delusions.MethodsTwenty-four first-episode schizophrenia patients with delusions and 18 without delusions as well as 26 healthy controls (HC underwent clinical assessment and whole-brain structural imaging which were acquired a 3.0 T scanner. Voxel-based morphometry was used to explore inter-group differences in gray matter volume using analysis of covariance, and Spearman correlation coefficients (rho between the Scale for the Assessment of Positive Symptoms (SAPS-delusion scores and mean regional brain volumes was obtained.ResultsPatients with delusions showed decreased brain gray matter volumes in the left putamen, thalamus, and caudate regions compared with HC. Patients with delusions also showed decreased regional volume in the left putamen and thalamus compared with patients without delusions. SAPS-delusion scores were negatively correlated with the gray matter volumes of the left putamen and thalamus.DiscussionLeft putamen and thalamus volume loss may be biological correlates of delusions in schizophrenia.

  15. Physiological adaptation of maternal plasma volume during pregnancy: a systematic review and meta-analysis.

    Science.gov (United States)

    de Haas, S; Ghossein-Doha, C; van Kuijk, S M J; van Drongelen, J; Spaanderman, M E A

    2017-02-01

    To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. We performed a meta-analysis of the current literature on plasma volume adjustments during physiological and complicated pregnancies. Literature was retrieved from PubMed (NCBI) and EMBASE (Ovid) databases. Included studies reported both reference plasma volume measurements (non-pregnant, prepregnancy or postpartum) and measurements obtained during predetermined gestational ages. Mean differences bet ween the reference and pregnancy plasma volume measurements were calculated for predefined intervals of gestational age using a random-effects model described by DerSimonian and Laird. Thirty studies were included in the meta-analysis with publication dates ranging from 1934 to 2007. Plasma volume increased in the first weeks of pregnancy, with the steepest increase occurring during the second trimester. Plasma volume continued to increase in the third trimester with a pooled maximum increase of 1.13 L (95% CI, 1.07-1.19 L), an increase of 45.6% (95% CI, 43.0-48.1%) in physiological pregnancies compared with the reference value. The plasma volume expansion in gestational hypertensive and growth-restricted pregnancies was 0.80 L (95% CI, 0.59-1.02 L), an increase of 32.3% (95% CI, 23.6-41.1%) in the third trimester, a smaller increase than in physiological pregnancies (P embarazo: una revisi\\xF3n sistemática y metaanálisis RESUMEN OBJETIVO: Describir el patrón fisiológico de los cambios en el volumen del plasma gestacional en embarazos normales con feto único y compararlo con el patrón en los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal. MÉTODOS: Se realizó un metaanálisis de la literatura actual sobre los cambios en el volumen de plasma durante

  16. Global (volume-averaged) model of inductively coupled chlorine plasma : influence of Cl wall recombination and external heating on continuous and pulse-modulated plasmas

    NARCIS (Netherlands)

    Kemaneci, E.H.; Carbone, E.A.D.; Booth, J.P.; Graef, W.A.A.D.; Dijk, van J.; Kroesen, G.M.W.

    An inductively coupled radio-frequency plasma in chlorine is investigated via a global (volume-averaged) model, both in continuous and square wave modulated power input modes. After the power is switched off (in a pulsed mode) an ion–ion plasma appears. In order to model this phenomenon, a novel

  17. Hippocampal volume is decreased in adults with hypothyroidism.

    Science.gov (United States)

    Cooke, Gillian E; Mullally, Sinead; Correia, Neuman; O'Mara, Shane M; Gibney, James

    2014-03-01

    Thyroid hormones are important for the adult brain, particularly regions of the hippocampus including the dentate gyrus and CA1 and CA3 regions. The hippocampus is a thyroid hormone receptor-rich region of the brain involved in learning and memory. Consequently, alterations in thyroid hormone levels have been reported to impair hippocampal-associated learning and memory, synaptic plasticity, and neurogenesis. While these effects have been shown primarily in developing rats, as well as in adult rats, little is known about the effects in adult humans. There are currently no data regarding structural changes in the hippocampus as a result of adult-onset hypothyroidism. We aimed to establish whether hippocampal volume was reduced in patients with untreated adult-onset hypothyroidism compared to age-matched healthy controls. High-resolution magnetization-prepared rapid acquisition with gradient echo (MPRAGE) scans were performed on 11 untreated hypothyroid adults and 9 age-matched control subjects. Hypothyroidism was diagnosed based on increased levels of thyrotropin (TSH) and reduced levels of free thyroxine (fT4). Volumetric analysis of the right and left hippocampal regions, using functional magnetic resonance imaging of the brain (FMRIB) integrated registration and segmentation tool (FIRST), demonstrated significant volume reduction in the right hippocampus in the hypothyroid patients relative to the control group. These findings provide preliminary evidence that hypothyroidism results in structural deficits in the adult human brain. Decreases in volume in the right hippocampus were evident in patients with adult-onset overt hypothyroidism, supporting some of the findings in animal models.

  18. A plasma melting technology for volume reduction of noncombustible radioactive waste in Korea

    International Nuclear Information System (INIS)

    Song, Myung Jae; Moon, Young Pyo

    1998-01-01

    In Korea, there is a strong need for the development of radioactive waste volume reduction technology. Korea Electric Power Research Institute (KEPRI) has been searching for ways to reduce the radioactive volume significantly and to produce stable waste forms. In particular, plasma treatment technology has caught KEPR's attention for treating noncombustible radwaste because this technology may far surpass conventional methods. The potential for greater control of temperature, faster reaction times, better control of processing, lower capital costs, greater throughput and more efficient use of energy is there. For the plasma melting study of noncombustible waste, KEPRI has leased a lab scale multipurpose plasma furnace system and performed preliminary tests. Using simulated noncombustible waste based on field survey data from nuclear power plants, lab scale melting experiments have been carried out. The properties of molten slag vary with additives and noncombustible waste materials. KEPRI's current study is focused on finding an optimum composition ratio of various noncombustible wastes for melting, investigating physical properties of molten slag, and obtaining operating parameters for continuous operation. (author)

  19. Lack of an association of BDNF Val66Met polymorphism and plasma BDNF with hippocampal volume and memory

    Science.gov (United States)

    Kim, Ana; Fagan, Anne M; Goate, Alison M; Benzinger, Tammie LS; Morris, John C; Head, Denise

    2015-01-01

    Brain-derived neurotrophic factor (BDNF) has been shown to be important for neuronal survival and synaptic plasticity in the hippocampus in non-human animals. The Val66Met polymorphism in the BDNF gene, involving a valine (Val) to methionine (Met) substitution at codon 66, has been associated with lower BDNF secretion in vitro. However, there have been mixed results regarding associations between either circulating BDNF or the BDNF Val66Met polymorphism with hippocampal volume and memory in humans. The current study examined the association of BDNF genotype and plasma BDNF with hippocampal volume and memory in two large independent cohorts of middle-aged and older adults (both cognitively normal and early-stage dementia). Sample sizes ranged from 123 to 649. Measures of the BDNF genotype, plasma BDNF, MRI-based hippocampal volume and memory performance were obtained from the Knight Alzheimer Disease Research Center (ADRC) and the Alzheimer’s Disease Neuroimaging Initiative (ADNI). There were no significant differences between BDNF Met+ and Met- groups on either hippocampal volume or memory in either cohort. In addition, plasma BDNF was not significantly associated with either hippocampal volume or memory in either cohort. Neither age, cognitive status nor gender moderated any of the relationships. Overall, current findings suggest that BDNF genotype and plasma BDNF may not be robust predictors for variance in hippocampal volume and memory in middle age and older adult cohorts. PMID:25784293

  20. Plasma prolactin and homovanillic acid as markers for psychopathology and abnormal movements after neuroleptic dose decrease.

    Science.gov (United States)

    Newcomer, J W; Riney, S J; Vinogradov, S; Csernansky, J G

    1992-01-01

    Plasma prolactin concentration (pPRL), plasma homovanillic acid concentration (pHVA), and symptomatology were measured in 24 male subjects with schizophrenia during maintenance haloperidol treatment. Fourteen subjects subsequently underwent 50 percent dose decreases under placebo-controlled, double-blind conditions. At baseline, a significant inverse correlation was found between pPRL and both tardive dyskinesia (TD) and "thinking disorder"; pPRL was directly correlated with negative symptoms. No such relationship was found with pHVA. In the patients who underwent a dose decrease, no relationship was found between baseline pPRL or pHVA and any clinical variable after the decrease. These data do not support the use of baseline pPRL or pHVA as markers of central dopamine function subsequent to a neuroleptic dose decrease.

  1. The influence of plasma density decreasement by pre-pulse on the laser wakefield acceleration

    Directory of Open Access Journals (Sweden)

    Ke-Gong Dong

    2011-12-01

    Full Text Available In the laser wakefield acceleration, the generation of electron beam is very sensitive to the plasma density. Not only the laser-wakefield interaction, but also the electron trapping and acceleration would be effected by the plasma density. However, the plasma density could be changed in the experiment by different reasons, which will result in the mismatch of parameters arranged initially. Forward Raman scattering spectrum demonstrated that the interaction density was decreased obviously in the experiment, which was verified by the pre-pulse conditions and two-dimensional particle-in-cell simulations. It was demonstrated that the plasma density was very important on the self-evolutions and energy coupling of laser pulse and wakefield, and eventually the energy spectrum of electron beam.

  2. Dietary Caprylic Acid (C8:0) Does Not Increase Plasma Acylated Ghrelin but Decreases Plasma Unacylated Ghrelin in the Rat

    Science.gov (United States)

    Lemarié, Fanny; Beauchamp, Erwan; Dayot, Stéphanie; Duby, Cécile; Legrand, Philippe; Rioux, Vincent

    2015-01-01

    Focusing on the caprylic acid (C8:0), this study aimed at investigating the discrepancy between the formerly described beneficial effects of dietary medium chain fatty acids on body weight loss and the C8:0 newly reported effect on food intake via ghrelin octanoylation. During 6 weeks, Sprague-Dawley male rats were fed with three dietary C8:0 levels (0, 8 and 21% of fatty acids) in three experimental conditions (moderate fat, caloric restriction and high fat). A specific dose-response enrichment of the stomach tissue C8:0 was observed as a function of dietary C8:0, supporting the hypothesis of an early preduodenal hydrolysis of medium chain triglycerides and a direct absorption at the gastric level. However, the octanoylated ghrelin concentration in the plasma was unchanged in spite of the increased C8:0 availability. A reproducible decrease in the plasma concentration of unacylated ghrelin was observed, which was consistent with a decrease in the stomach preproghrelin mRNA and stomach ghrelin expression. The concomitant decrease of the plasma unacylated ghrelin and the stability of its acylated form resulted in a significant increase in the acylated/total ghrelin ratio which had no effect on body weight gain or total dietary consumption. This enhanced ratio measured in rats consuming C8:0 was however suspected to increase (i) growth hormone (GH) secretion as an increase in the GH-dependent mRNA expression of the insulin like growth Factor 1 (IGF-1) was measured (ii) adipocyte diameters in subcutaneous adipose tissue without an increase in the fat pad mass. Altogether, these results show that daily feeding with diets containing C8:0 increased the C8:0 level in the stomach more than all the other tissues, affecting the acylated/total ghrelin plasma ratio by decreasing the concentration of circulating unacylated ghrelin. However, these modifications were not associated with increased body weight or food consumption. PMID:26196391

  3. Insomnia severity is associated with a decreased volume of the CA3/Dentate Gyrus Hippocampal Subfield

    Science.gov (United States)

    Neylan, Thomas C.; Mueller, Susanne G.; Wang, Zhen; Metzler, Thomas J.; Lenoci, Maryann; Truran, Diana; Marmar, Charles R.; Weiner, Michael W.; Schuff, Norbert

    2010-01-01

    Background Prolonged disruption of sleep in animal studies is associated with decreased neurogenesis in the dentate gyrus. Our objective was to determine if insomnia severity in a sample of PTSD and controls was associated with decreased volume in the CA3/dentate hippocampal subfield. Methods Volumes of hippocampal subfields in seventeen veteran males positive for PTSD (41 ±12 years) and nineteen age-matched male veterans negative for PTSD were measured using 4 Tesla MRI. Subjective sleep quality was measured by the Insomnia Severity Index (ISI) and the Pittsburgh Sleep Quality Index (PSQI). Results Higher scores on the ISI, indicating worse insomnia, were associated with smaller volumes of the CA3/dentate subfields (r= −.48, p < 0.01) in the combined sample. Adding the ISI score as a predictor for CA3/dentate volume to a hierarchical linear regression model after first controlling for age and PTSD symptoms accounted for a 13 % increase in incremental variance (t= −2.47, p= 0.02). Conclusions The findings indicate for the first time in humans that insomnia severity is associated with volume loss of the CA3/dentate subfields. This is consistent with animal studies showing that chronic sleep disruption is associated with decreased neurogenesis and dendritic branching in these structures. PMID:20598672

  4. Blood Volume: Importance and Adaptations to Exercise Training, Environmental Stresses and Trauma/Sickness

    Science.gov (United States)

    Sawka, Michael N.; Convertino, Victor A.; Eichner, E. Randy; Schnieder, Suzanne M.; Young, Andrew J.

    2000-01-01

    This paper reviews the influence of several perturbations (physical exercise, heat stress, terrestrial altitude, microgravity, and trauma/sickness) on adaptations of blood volume (BV), erythrocyte volume (EV), and plasma volume (PV). Exercise training can induced BV expansion; PV expansion usually occurs immediately, but EV expansion takes weeks. EV and PV expansion contribute to aerobic power improvements associated with exercise training. Repeated heat exposure induces PV expansion but does not alter EV. PV expansion does not improve thermoregulation, but EV expansion improves thermoregulation during exercise in the heat. Dehydration decreases PV (and increases plasma tonicity) which elevates heat strain and reduces exercise performance. High altitude exposure causes rapid (hours) plasma loss. During initial weeks at altitude, EV is unaffected, but a gradual expansion occurs with extended acclimatization. BV adjustments contribute, but are not key, to altitude acclimatization. Microgravity decreases PV and EV which contribute to orthostatic intolerance and decreased exercise capacity in astronauts. PV decreases may result from lower set points for total body water and central venous pressure, which EV decrease bay result form increased erythrocyte destruction. Trauma, renal disease, and chronic diseases cause anemia from hemorrhage and immune activation, which suppressions erythropoiesis. The re-establishment of EV is associated with healing, improved life quality, and exercise capabilities for these injured/sick persons.

  5. Performance of large electron energy filter in large volume plasma device

    International Nuclear Information System (INIS)

    Singh, S. K.; Srivastava, P. K.; Awasthi, L. M.; Mattoo, S. K.; Sanyasi, A. K.; Kaw, P. K.; Singh, R.

    2014-01-01

    This paper describes an in-house designed large Electron Energy Filter (EEF) utilized in the Large Volume Plasma Device (LVPD) [S. K. Mattoo, V. P. Anita, L. M. Awasthi, and G. Ravi, Rev. Sci. Instrum. 72, 3864 (2001)] to secure objectives of (a) removing the presence of remnant primary ionizing energetic electrons and the non-thermal electrons, (b) introducing a radial gradient in plasma electron temperature without greatly affecting the radial profile of plasma density, and (c) providing a control on the scale length of gradient in electron temperature. A set of 19 independent coils of EEF make a variable aspect ratio, rectangular solenoid producing a magnetic field (B x ) of 100 G along its axis and transverse to the ambient axial field (B z ∼ 6.2 G) of LVPD, when all its coils are used. Outside the EEF, magnetic field reduces rapidly to 1 G at a distance of 20 cm from the center of the solenoid on either side of target and source plasma. The EEF divides LVPD plasma into three distinct regions of source, EEF and target plasma. We report that the target plasma (n e ∼ 2 × 10 11  cm −3 and T e ∼ 2 eV) has no detectable energetic electrons and the radial gradients in its electron temperature can be established with scale length between 50 and 600 cm by controlling EEF magnetic field. Our observations reveal that the role of the EEF magnetic field is manifested by the energy dependence of transverse electron transport and enhanced transport caused by the plasma turbulence in the EEF plasma

  6. High tidal volume decreases adult respiratory distress syndrome, atelectasis, and ventilator days compared with low tidal volume in pediatric burned patients with inhalation injury.

    Science.gov (United States)

    Sousse, Linda E; Herndon, David N; Andersen, Clark R; Ali, Arham; Benjamin, Nicole C; Granchi, Thomas; Suman, Oscar E; Mlcak, Ronald P

    2015-04-01

    Inhalation injury, which is among the causes of acute lung injury and acute respiratory distress syndrome (ARDS), continues to represent a significant source of mortality in burned patients. Inhalation injury often requires mechanical ventilation, but the ideal tidal volume strategy is not clearly defined in burned pediatric patients. The aim of this study was to determine the effects of low and high tidal volume on the number of ventilator days, ventilation pressures, and incidence of atelectasis, pneumonia, and ARDS in pediatric burned patients with inhalation injury within 1 year post burn injury. From 1986 to 2014, inhalation injury was diagnosed by bronchoscopy in pediatric burned patients (n = 932). Patients were divided into 3 groups: unventilated (n = 241), high tidal volume (HTV, 15 ± 3 mL/kg, n = 190), and low tidal volume (LTV, 9 ± 3 mL/kg, n = 501). High tidal volume was associated with significantly decreased ventilator days (p tidal volume significantly decreases ventilator days and the incidence of both atelectasis and ARDS compared with low tidal volume in pediatric burned patients with inhalation injury. Therefore, the use of HTV may interrupt sequences leading to lung injury in our patient population. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Impact of Plasma Epstein-Barr Virus-DNA and Tumor Volume on Prognosis of Locally Advanced Nasopharyngeal Carcinoma

    Directory of Open Access Journals (Sweden)

    Meng Chen

    2015-01-01

    Full Text Available This retrospective study aims to examine the association of plasma Epstein-Barr virus- (EBV- DNA levels with the tumor volume and prognosis in patients with locally advanced nasopharyngeal carcinoma (NPC. A total of 165 patients with newly diagnosed locally advanced NPC were identified from September 2011 to July 2012. EBV-DNA was detected using fluorescence quantitative polymerase chain reaction (PCR amplification. The tumor volume was calculated by the systematic summation method of computer software. The median copy number of plasma EBV-DNA before treatment was 3790 copies/mL. The median gross tumor volume of the primary nasopharyngeal tumor (GTVnx, the lymph node lesions (GTVnd, and the total GTV before treatment were 72.46, 23.26, and 106.25 cm3, respectively; the EBV-DNA levels were significantly correlated with the GTVnd and the total GTV (P<0.01. The 2-year overall survival (OS rates in patients with positive and negative pretreatment plasma EBV-DNA were 100% and 98.4% (P=1.000, and the disease-free survival (DFS rates were 94.4% and 80.8% (P=0.044, respectively. These results indicate that high pretreatment plasma EBV-DNA levels in patients with locally advanced NPC are associated with the degree of lymph node metastasis, tumor burden, and poor prognosis.

  8. Electro-mechanical probe positioning system for large volume plasma device

    Science.gov (United States)

    Sanyasi, A. K.; Sugandhi, R.; Srivastava, P. K.; Srivastav, Prabhakar; Awasthi, L. M.

    2018-05-01

    An automated electro-mechanical system for the positioning of plasma diagnostics has been designed and implemented in a Large Volume Plasma Device (LVPD). The system consists of 12 electro-mechanical assemblies, which are orchestrated using the Modbus communication protocol on 4-wire RS485 communications to meet the experimental requirements. Each assembly has a lead screw-based mechanical structure, Wilson feed-through-based vacuum interface, bipolar stepper motor, micro-controller-based stepper drive, and optical encoder for online positioning correction of probes. The novelty of the system lies in the orchestration of multiple drives on a single interface, fabrication and installation of the system for a large experimental device like the LVPD, in-house developed software, and adopted architectural practices. The paper discusses the design, description of hardware and software interfaces, and performance results in LVPD.

  9. Decreased plasma neurotrophin-4/5 levels in bipolar disorder patients in mania.

    Science.gov (United States)

    Barbosa, Izabela G; Morato, Isabela B; Huguet, Rodrigo B; Rocha, Fabio L; Machado-Vieira, Rodrigo; Teixeira, Antônio L

    2014-01-01

    To evaluate two poorly explored neurotrophins (NT), NT-3 and NT-4/5, in bipolar disorder (BD). Forty patients with type I BD (18 in remission and 22 in mania) and 25 healthy controls matched for age, gender, and educational attainment were enrolled in this study. All subjects were assessed by the Mini-International Neuropsychiatric Interview; the Young Mania Rating Scale and the Hamilton Depression Rating Scale were used to evaluate severity of symptoms in BD patients. Plasma levels of NT-3 and NT-4/5 were measured by enzyme-linked immunosorbent assay (ELISA). BD patients in mania presented decreased NT-4/5 plasma levels in comparison with controls (p neurotrophin dysfunction is associated with mood states in patients with BD.

  10. Plasma properties in a large-volume, cylindrical and asymmetric radio-frequency capacitively coupled industrial-prototype reactor

    International Nuclear Information System (INIS)

    Lazović, Saša; Puač, Nevena; Spasić, Kosta; Malović, Gordana; Petrović, Zoran Lj; Cvelbar, Uroš; Mozetič, Miran; Radetić, Maja

    2013-01-01

    We have developed a large-volume low-pressure cylindrical plasma reactor with a size that matches industrial reactors for treatment of textiles. It was shown that it efficiently produces plasmas with only a small increase in power as compared with a similar reactor with 50 times smaller volume. Plasma generated at 13.56 MHz was stable from transition to streamers and capable of long-term continuous operation. An industrial-scale asymmetric cylindrical reactor of simple design and construction enabled good control over a wide range of active plasma species and ion concentrations. Detailed characterization of the discharge was performed using derivative, Langmuir and catalytic probes which enabled determination of the optimal sets of plasma parameters necessary for successful industry implementation and process control. Since neutral atomic oxygen plays a major role in many of the material processing applications, its spatial profile was measured using nickel catalytic probe over a wide range of plasma parameters. The spatial profiles show diffusion profiles with particle production close to the powered electrode and significant wall losses due to surface recombination. Oxygen atom densities range from 10 19 m −3 near the powered electrode to 10 17 m −3 near the wall. The concentrations of ions at the same time are changing from 10 16 to the 10 15 m −3 at the grounded chamber wall. (paper)

  11. Enhancement of H{sup -}/D{sup -} volume production in a double plasma type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Nishimura, Hideki; Sakiyama, Satoshi [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    H{sup -}/D{sup -} production in a pure volume source has been studied. In our double plasma type negative ion source, both energy and density of fast electrons are well controlled. With the use of this source, the enhancement of H{sup -}/D{sup -} production has been observed. Namely, under the same discharge power, the extracted H{sup -}/D{sup -} current in the double plasma operation is higher than that in the single plasma operation. At the same time, measurements of plasma parameters have been made in the source and the extractor regions for these two cases. (author)

  12. Soluble CD206 plasma levels in rheumatoid arthritis reflect decrease in disease activity

    DEFF Research Database (Denmark)

    Heftdal, Line Dam; Stengaard-Pedersen, Kristian; Ørnbjerg, Lykke Midtbøll

    2017-01-01

    internalization and degradation. The soluble form has been suggested as a biomarker of M2A-macrophage activation. The aim of this study was to investigate sCD206 plasma levels in early RA patients initiating anti-TNFα treatment. Plasma levels of sCD206 were measured by ELISA in samples from 155 early RA patients...... from baseline after 6 months. In the ADA group, however, levels remained lower than baseline throughout the treatment period. In conclusion, initially, plasma sCD206 in early RA patients decreased in accordance with disease activity and initiation of DMARD treatment. Treatment with anti-TNFα preserved......Rheumatoid arthritis (RA) is characterized by chronic joint inflammation and infiltration by activated macrophages. TNFα is a central mediator in this process. The mannose receptor, CD206, is a scavenger receptor expressed by M2A-macrophages and dendritic cells. It is involved in collagen...

  13. The component content of active particles in a plasma-chemical reactor based on volume barrier discharge

    Science.gov (United States)

    Soloshenko, I. A.; Tsiolko, V. V.; Pogulay, S. S.; Terent'yeva, A. G.; Bazhenov, V. Yu; Shchedrin, A. I.; Ryabtsev, A. V.; Kuzmichev, A. I.

    2007-02-01

    In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O3, HNO3, HNO2, N2 O5 and NO3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm-3. It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O3, HNO3, HNO2, N2O5 and NO3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values.

  14. The component content of active particles in a plasma-chemical reactor based on volume barrier discharge

    International Nuclear Information System (INIS)

    Soloshenko, I A; Tsiolko, V V; Pogulay, S S; Terent'yeva, A G; Bazhenov, V Yu; Shchedrin, A I; Ryabtsev, A V; Kuzmichev, A I

    2007-01-01

    In this paper the results of theoretical and experimental studies of the component content of active particles formed in a plasma-chemical reactor composed of a multiple-cell generator of active particles, based on volume barrier discharge, and a working chamber are presented. For calculation of the content of uncharged plasma components an approach is proposed which is based on averaging of the power introduced over the entire volume. Advantages of such an approach lie in an absence of fitting parameters, such as the dimensions of microdischarges, their surface density and rate of breakdown. The calculation and the experiment were accomplished with the use of dry air (20% relative humidity) as the plasma generating medium. Concentrations of O 3 , HNO 3 , HNO 2 , N 2 O 5 and NO 3 were measured experimentally in the discharge volume and working chamber for the residence time of particles on a discharge of 0.3 s and more and discharge specific power of 1.5 W cm -3 . It has been determined that the best agreement between the calculation and the experiment occurs at calculated gas medium temperatures in the discharge plasma of about 400-425 K, which correspond to the experimentally measured rotational temperature of nitrogen. In most cases the calculated concentrations of O 3 , HNO 3 , HNO 2 , N 2 O 5 and NO 3 for the barrier discharge and the working chamber are in fairly good agreement with the respective measured values

  15. Physiological adaptation of maternal plasma volume during pregnancy: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Haas, S.; Ghossein-Doha, C.; Kuijk, S.M. van; Drongelen, J. van; Spaanderman, M.E.A.

    2017-01-01

    OBJECTIVE: To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. METHODS: We performed a meta-analysis of

  16. Decreased maternal plasma apelin concentrations in preeclampsia.

    Science.gov (United States)

    Bortoff, Katherine D; Qiu, Chunfang; Runyon, Scott; Williams, Michelle A; Maitra, Rangan

    2012-01-01

    Preeclampsia is a hypertensive disorder that complicates 3-7% of pregnancies. The development of preeclampsia has not been completely elucidated and current therapies are not broadly efficacious. The apelinergic system appears to be involved in hypertensive disorders and experimental studies indicate a role of this system in preeclampsia. Thus, an epidemiological evaluation of apelin protein concentration in plasma was conducted in case-control study of pregnant women. Data and maternal plasma samples were collected from pregnant women with confirmed preeclampsia (n = 76) or normotensive controls (n = 79). Concentrations of apelin peptides were blindly measured using enzyme-linked immunosorbent assay. Data were subjected to statistical analyses. Plasma apelin concentrations, measured at delivery, were lower in preeclampsia cases compared with controls (mean ± standard deviation: 0.66 ± 0.29 vs. 0.78 ± 0.31 ng/mL, p = 0.02). After controlling for confounding by maternal age, smoking status, and pre-pregnancy body mass index, odds of preeclampsia were 48% lower for women with high versus low plasma apelin (≥0.73 vs. preclampsia and other hypertensive maternal disorders.

  17. Decreased right heart blood volume determined by magnetic resonance imaging: evidence of central underfilling in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Søndergaard, L; Møgelvang, J

    1995-01-01

    mL, NS), and left atrial volume (70 vs. 57 mL, P = .08) were normal or slightly increased. The right ejection fraction (68% vs. 53%, P fraction was slightly reduced (61% vs. 69%, NS). The central and arterial blood volume (CBV), assessed......Whether the central blood volume is reduced or expanded in cirrhosis is still under debate. Accordingly, the current study was undertaken to assess the volume of the heart cavities. Ten cirrhotic patients and matched controls had their right and left ventricular end-diastolic volumes (RVDV and LVDV...... as the cardiac output (CO) multiplied by the central circulation time, was significantly decreased (1.47 vs. 1.81 L, P blood volume (4.43 vs. 3.64 L, P

  18. Development of volume-reduction system for ion exchange resin using inductively coupled plasma

    International Nuclear Information System (INIS)

    Fujisawa, Morio; Katagiri, Genichi

    2002-01-01

    The spent ion exchange resin generated as radioactive waste in water purifying system at nuclear power stations or related facilities of nuclear power has been stored in the site, and its volume has been increasing year by year. We had developed a full-scale system of IC plasma volume-reduction system for the spent resin, and have performed basic performance test using some samples imitating the spent resin. As the results, the imitation of the resin can be reduced in volume by more than 90% so that the processing performance in actual scale was proved to be effective. In addition, it was clarified that the residuum after volume-reduction process is easy to mix with cement, and solidity containing 30wt% residuum provides high strength of 68 MPa. Therefore, we evaluate the application of this process to stabilization of the disposal to be very effective. (author)

  19. Electrical method for the measurements of volume averaged electron density and effective coupled power to the plasma bulk

    Science.gov (United States)

    Henault, M.; Wattieaux, G.; Lecas, T.; Renouard, J. P.; Boufendi, L.

    2016-02-01

    Nanoparticles growing or injected in a low pressure cold plasma generated by a radiofrequency capacitively coupled capacitive discharge induce strong modifications in the electrical parameters of both plasma and discharge. In this paper, a non-intrusive method, based on the measurement of the plasma impedance, is used to determine the volume averaged electron density and effective coupled power to the plasma bulk. Good agreements are found when the results are compared to those given by other well-known and established methods.

  20. Decrease in coronary vascular volume in systole augments cardiac contraction.

    Science.gov (United States)

    Willemsen, M J; Duncker, D J; Krams, R; Dijkman, M A; Lamberts, R R; Sipkema, P; Westerhof, N

    2001-08-01

    Coronary arterial inflow is impeded and venous outflow is increased as a result of the decrease in coronary vascular volume due to cardiac contraction. We evaluated whether cardiac contraction is influenced by interfering with the changes of the coronary vascular volume over the heart cycle. Length-tension relationships were determined in Tyrode-perfused rat papillary muscle and when coronary vascular volume changes were partly inhibited by filling it with congealed gelatin or perfusing it with a high viscosity dextran buffer. Also, myocyte thickening during contraction was reduced by placing a silicon tube around the muscle. Increasing perfusion pressure from 8 to 80 cmH2O, increased developed tension by approximately 40%. When compared with the low perfusion state, developed tension of the gelatin-filled vasculature was reduced to 43 +/- 6% at the muscle length where the muscle generates the largest developed tension (n = 5, means +/- SE). Dextran reduced developed tension to 73 +/- 6% (n = 6). The silicon tube, in low perfusion state, reduced the developed tension to 83 +/- 7% (n = 4) of control. Time-control and oxygen-lowering experiments show that the findings are based on mechanical effects. Thus interventions to prevent myocyte thickening reduce developed tension. We hypothesize that when myocyte thickening is prevented, intracellular pressure increases and counteracts the force produced by the contractile apparatus. We conclude that emptying of the coronary vasculature serves a physiological purpose by facilitating cardiomyocyte thickening thereby augmenting force development.

  1. Influence of an additional ballast volume on a pulsed ICP discharge

    International Nuclear Information System (INIS)

    Bogdanov, E A; Jr, C A DeJoseph; Demidov, V I; Kudryavtsev, A A; Serditov, K Yu

    2007-01-01

    A spatial and temporal numerical simulation has been carried out of a pulsed (100% modulated), rf inductively coupled plasma discharge in argon, connected to an additional (ballast) diffusion chamber of much larger volume. It is demonstrated that during the active phase, the presence of the large ballast volume has a small impact on the parameters of the plasma in the smaller discharge chamber. In this case the plasma parameters in the discharge chamber can be estimated separately from the diffusion chamber by a standard method using the characteristic ambipolar diffusion time (for example, using a global model). However, during the afterglow phase, the situation is changed significantly. In the afterglow, the densities of charged particles in the discharge chamber become lower than in the large ballast chamber due to more rapid diffusion loss. As a result, the reverse of the active phase situation occurs, namely, the plasma does not flow from the small to the large chamber, but in the opposite direction, from diffusive to discharge volume, and both the plasma density gradient and the self-consistent ambipolar electric field in the small chamber change directions. This phenomenon leads to new effects in the discharge volume, in particular a decreasing rate of decay of densities of charged particles and electron temperature. Thus, in the afterglow the presence of a large additional ballast volume has a significant impact on the plasma transport. In this case, a simple treatment of the plasma in the discharge chamber in the framework of a spatially averaged model (for example, the global model) is inadequate

  2. Factors Affecting Canagliflozin-Induced Transient Urine Volume Increase in Patients with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Tanaka, Hiroyuki; Takano, Kazuhiko; Iijima, Hiroaki; Kubo, Hajime; Maruyama, Nobuko; Hashimoto, Toshio; Arakawa, Kenji; Togo, Masanori; Inagaki, Nobuya; Kaku, Kohei

    2017-02-01

    Sodium glucose co-transporter 2 (SGLT2) inhibitors exhibit diuretic activity, which is a possible mechanism underlying the cardiovascular benefit of these inhibitors. However, the osmotic diuresis-induced increase in urine volume, and the risk of dehydration have been of concern with SGLT2 inhibitor treatment. This study aimed to investigate the mechanism underlying SGLT2 inhibitor canagliflozin-induced diuresis in Japanese type 2 diabetes mellitus (T2DM) patients. Thirteen T2DM patients received a daily oral dose of 100 mg canagliflozin before breakfast for 6 days. Blood and urine samples were collected at predetermined time points. The primary endpoint was evaluation of correlations between changes from baseline in urine volume and factors that are known to affect urine volume and between actual urine volume and these factors. Canagliflozin transiently increased urine volume and urinary sodium excretion on Day 1 with a return to baseline levels thereafter. Canagliflozin administration increased urinary glucose excretion, which was sustained during repeated-dose administration. Plasma atrial natriuretic peptide (ANP) and N-terminal pro-b-type natriuretic peptide (NT-proBNP) levels decreased, while plasma renin activity increased. On Day 1 of treatment, changes in sodium and potassium excretion were closely correlated with changes in urine output. A post hoc multiple regression analysis showed changes in sodium excretion and water intake as factors that affected urine volume change at Day 1. Furthermore, relative to that at baseline, canagliflozin decreased blood glucose throughout the day and increased plasma total GLP-1 after breakfast. Canagliflozin induced transient sodium excretion and did not induce water intake at Day 1; hence, natriuresis rather than glucose-induced osmotic diuresis may be a major factor involved in the canagliflozin-induced transient increase in urine output. In addition, canagliflozin decreased plasma ANP and NT-proBNP levels and

  3. Process automation system for integration and operation of Large Volume Plasma Device

    International Nuclear Information System (INIS)

    Sugandhi, R.; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2016-01-01

    Highlights: • Analysis and design of process automation system for Large Volume Plasma Device (LVPD). • Data flow modeling for process model development. • Modbus based data communication and interfacing. • Interface software development for subsystem control in LabVIEW. - Abstract: Large Volume Plasma Device (LVPD) has been successfully contributing towards understanding of the plasma turbulence driven by Electron Temperature Gradient (ETG), considered as a major contributor for the plasma loss in the fusion devices. Large size of the device imposes certain difficulties in the operation, such as access of the diagnostics, manual control of subsystems and large number of signals monitoring etc. To achieve integrated operation of the machine, automation is essential for the enhanced performance and operational efficiency. Recently, the machine is undergoing major upgradation for the new physics experiments. The new operation and control system consists of following: (1) PXIe based fast data acquisition system for the equipped diagnostics; (2) Modbus based Process Automation System (PAS) for the subsystem controls and (3) Data Utilization System (DUS) for efficient storage, processing and retrieval of the acquired data. In the ongoing development, data flow model of the machine’s operation has been developed. As a proof of concept, following two subsystems have been successfully integrated: (1) Filament Power Supply (FPS) for the heating of W- filaments based plasma source and (2) Probe Positioning System (PPS) for control of 12 number of linear probe drives for a travel length of 100 cm. The process model of the vacuum production system has been prepared and validated against acquired pressure data. In the next upgrade, all the subsystems of the machine will be integrated in a systematic manner. The automation backbone is based on 4-wire multi-drop serial interface (RS485) using Modbus communication protocol. Software is developed on LabVIEW platform using

  4. Process automation system for integration and operation of Large Volume Plasma Device

    Energy Technology Data Exchange (ETDEWEB)

    Sugandhi, R., E-mail: ritesh@ipr.res.in; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2016-11-15

    Highlights: • Analysis and design of process automation system for Large Volume Plasma Device (LVPD). • Data flow modeling for process model development. • Modbus based data communication and interfacing. • Interface software development for subsystem control in LabVIEW. - Abstract: Large Volume Plasma Device (LVPD) has been successfully contributing towards understanding of the plasma turbulence driven by Electron Temperature Gradient (ETG), considered as a major contributor for the plasma loss in the fusion devices. Large size of the device imposes certain difficulties in the operation, such as access of the diagnostics, manual control of subsystems and large number of signals monitoring etc. To achieve integrated operation of the machine, automation is essential for the enhanced performance and operational efficiency. Recently, the machine is undergoing major upgradation for the new physics experiments. The new operation and control system consists of following: (1) PXIe based fast data acquisition system for the equipped diagnostics; (2) Modbus based Process Automation System (PAS) for the subsystem controls and (3) Data Utilization System (DUS) for efficient storage, processing and retrieval of the acquired data. In the ongoing development, data flow model of the machine’s operation has been developed. As a proof of concept, following two subsystems have been successfully integrated: (1) Filament Power Supply (FPS) for the heating of W- filaments based plasma source and (2) Probe Positioning System (PPS) for control of 12 number of linear probe drives for a travel length of 100 cm. The process model of the vacuum production system has been prepared and validated against acquired pressure data. In the next upgrade, all the subsystems of the machine will be integrated in a systematic manner. The automation backbone is based on 4-wire multi-drop serial interface (RS485) using Modbus communication protocol. Software is developed on LabVIEW platform using

  5. Contrast media osmolality and plasma volume changes

    International Nuclear Information System (INIS)

    Hine, A.L.; Lui, D.; Dawson, P.; Middlesex Hospital, London

    1985-01-01

    A theoretical and experimental study of the plasma volume expansion consequent on the hyperosmolality of contrast media is presented. In the case of the ratio 1.5 media theory and experiment coincide closely but in the case of the ratio 3 media the observed changes exceed the predicted. It is proposed that this is due partly to the slower diffusion of the ratio 3 media out of the intravascular space and partly due to the fact that the osmotic load presented by these media is greater than would be expected from a study of their commercial solutions in which osmolality is reduced by molecular aggregation. The implications for the relative haemodynamic effects of different contrast media are discussed. The osmotic effects of contrast media also play a part in determining the image quality achievable in intravenous digital subtraction angiography (IV-DSA). It is predicted that ratio 3 contrast media will give better quality images in IV-DSA than ratio 1.5 media. (orig.)

  6. The Blood Volume of the Guinea Pig: Effects of Epinephrine and Isoproterenol upon the Red Cell and Plasma Volumes, Heart Rate, and Mean Arterial Pressure,

    Science.gov (United States)

    1987-09-01

    capillaries (4), blood volumes calculated from plasma volume measures must correct for label that has left the system between the time of the injected dose...Splenic sequestration and contraction are mediated by the autonomic nervous system and blood-borne agents (10). Sympathetic nerve fibers from the truncus...sympathlcus and parasympathetic neurons of the nervus vagus (cranial nerve X) innervate the celiac plexus (8, 11). A subdivision of the celiac plexus

  7. Changes in Plasma Copeptin Levels during Hemodialysis: Are the Physiological Stimuli Active in Hemodialysis Patients?

    Directory of Open Access Journals (Sweden)

    Esmée M Ettema

    Full Text Available Plasma levels of copeptin, a surrogate marker for the vasoconstrictor hormone arginine vasopressin (AVP, are increased in hemodialysis patients. Presently, it is unknown what drives copeptin levels in hemodialysis patients. We investigated whether the established physiological stimuli for copeptin release, i.e. plasma osmolality, blood volume and mean arterial pressure (MAP, are operational in hemodialysis patients.One hundred and eight prevalent, stable hemodialysis patients on a thrice-weekly dialysis schedule were studied during hemodialysis with constant ultrafiltration rate and dialysate conductivity in this observational study. Plasma levels of copeptin, sodium, MAP, and blood volume were measured before, during and after hemodialysis. Multivariate analysis was used to determine the association between copeptin (dependent variable and the physiological stimuli plasma sodium, MAP, excess weight as well as NT-pro-BNP immediately prior to dialysis and between copeptin and changes of plasma sodium, MAP and blood volume with correction for age, sex and diabetes during dialysis treatment.Patients were 63 ± 15.6 years old and 65% were male. Median dialysis vintage was 1.6 years (IQR 0.7-4.0. Twenty-three percent of the patients had diabetes and 82% had hypertension. Median predialysis copeptin levels were 141.5 pmol/L (IQR 91.0-244.8 pmol/L. Neither predialysis plasma sodium levels, nor NT-proBNP levels, nor MAP were associated with predialysis copeptin levels. During hemodialysis, copeptin levels rose significantly (p<0.01 to 163.0 pmol/L (96.0-296.0 pmol/L. Decreases in blood volume and MAP were associated with increases in copeptin levels during dialysis, whereas there was no significant association between the change in plasma sodium levels and the change in copeptin levels.Plasma copeptin levels are elevated predialysis and increase further during hemodialysis. Volume stimuli, i.e. decreases in MAP and blood volume, rather than osmotic

  8. Numerical analysis on the ion species ratios in a steady state hydrogen plasma

    International Nuclear Information System (INIS)

    Fukumasa, Osamu; Saeki, Setsuo; Osaki, Katashi; Sakiyama, Satoshi; Itatani, Ryohei.

    1984-07-01

    Ion species ratios in a hydrogen plasma are calculated systematically as a function of plasma parameters, i.e. the electron density, the electron temperature, the pressure of hydrogen gas and the plasma volume. Furthermore, in the present analysis, the recombination factor for hydrogen atoms at the wall surface of a vacuum vessel is treated as another plasma parameter. The most significant point is that ion species ratios depend strongly not only on plasma parameters, but also on the recombination factor. The proton ratio increases with decreasing value of the recombination factor. Primary electrons also play an important role for ion species ratios, and the presence of primary electrons causes the proton ratio to decrease. (author)

  9. Proceedings of the international symposium on environmental technologies: Plasma systems and applications. Volume 1

    International Nuclear Information System (INIS)

    Mayne, P.W.; Mulholland, J.A.

    1995-01-01

    Plasma technology is an extremely versatile and powerful means of obtaining very high temperatures that can be used in a variety of environmental situations. Since most types of waste products and contaminants can be treated effectively and efficiently, plasma systems have been developed to address the disposal and annihilation domestic of medical, hazardous, radioactive, military, and miscellaneous wastes. Plasma technologies can also be implemented to recycle and recover usable materials from metallic wastes. The International Symposium on Environmental Technologies: Plasma Systems and Applications was held at the Omni Hotel in Atlanta, Georgia on October 8--12, 1995 to bring together a large group of technical experts working on the use of plasma for solving environmental problems. The Symposium is a sequel to the 1994 Metatechnies Conference on Stabilization and Volarization of Ultimate Waste by Plasma Processes that was held in September of 1994 at Bordeaux Lac, France. The proceedings to this second international conference contain the written contributions from eleven sessions and are published in two volumes. A total of 65 papers address the use of plasma systems for environmental applications and include topics concerning the development and use of innovative technologies for waste treatment, environmental remediation, recycling, characterization of the plasma and solid residue, off-gas analyses, as well as case studies and regulatory policies

  10. Identification of lysophosphatidylcholine, γ-stearoyl (LPCD) as an endogenous Na+, K+-ATPase inhibitor in volume-expanded hog plasma

    International Nuclear Information System (INIS)

    Tamura, M.; Inagami, T.

    1986-01-01

    We have shown that the Na + , K + -ATPase inhibitory activities in the plasma of volume-expanded hog consist of multiple components. One group of the major inhibitory activities induced by intravascular saline infusion was identified as unsaturated free fatty acids. The present study was undertaken to determine the identity of the remaining Na + , K + -ATPase inhibitory activity in the plasma of volume-expanded hogs. Three peaks with ouabain displacing activity (ODA) were separated by HPLC on a reversed phase octadecyl column. The slowest eluting material which showed good solubility in water and recognizable optical absorbance at 214 nm was purified further by three additional steps of reverse phase HPLC. FAB mass spectrometry and 1 H NMR spectroscopy identified this substance as lysophosphatidylcholine, γ-stearoyl. Both purified and synthetic LPCS showed dose-dependent inhibition of Na + , K + -ATPase and displacement of [ 3 H] ouabain from the ATPase. Lysophosphatidylcholines containing either palmitoyl or myristoyl groups also exhibited the Na + , K + -ATPase inhibitory activity and the ODA. The ODA in the LPCS containing fraction increased during the saline infusion. These results indicate that LPCS is an endogenous Na + , K + -ATPase inhibitor which is induced by the expansion of plasma volume

  11. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Neurologia e Psicologia Medica]. E-mail: fgraeff@keynet.com.br; Santos, A.C. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Clinica Medica; Guimaraes, F.S. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Dept. de Farmacologia

    2003-07-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t{sub 21} = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t{sub 21} = 1.99, P = 0.06), right amygdala (8%, t{sub 21} = 1.83, P = 0.08), left amygdala (5%, t{sub 21} = 1.78, P 0.09) and left hippocampus (9%, t{sub 21} = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  12. Decreased left temporal lobe volume of panic patients measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Uchida, R.R.; Del-Ben, C.M.; Araujo, D.; Crippa, J.A.; Graeff, F.G.; Santos, A.C.; Guimaraes, F.S.

    2003-01-01

    Reported neuroimaging studies have shown functional and morphological changes of temporal lobe structures in panic patients, but only one used a volumetric method. The aim of the present study was to determine the volume of temporal lobe structures in patients with panic disorder, measured by magnetic resonance imaging. Eleven panic patients and eleven controls matched for age, sex, handedness, socioeconomic status and years of education participated in the study. The mean volume of the left temporal lobe of panic patients was 9% smaller than that of controls (t 21 = 2.37, P = 0.028). In addition, there was a trend (P values between 0.05 and 0.10) to smaller volumes of the right temporal lobe (7%, t 21 = 1.99, P = 0.06), right amygdala (8%, t 21 = 1.83, P = 0.08), left amygdala (5%, t 21 = 1.78, P 0.09) and left hippocampus (9%, t 21 = 1.93, P = 0.07) in panic patients compared to controls. There was a positive correlation between left hippocampal volume and duration of panic disorder (r = 0.67, P = 0.025), with recent cases showing more reduction than older cases. The present results show that panic patients have a decreased volume of the left temporal lobe and indicate the presence of volumetric abnormalities of temporal lobe structures. (author)

  13. Decreased material-activation of the complement system using low-energy plasma polymerized poly(vinyl pyrrolidone) coatings

    DEFF Research Database (Denmark)

    Andersen, T.E.; Kolmos, H.J.; Palarasah, Yaseelan

    2011-01-01

    In the current study we investigate the activation of blood complement on medical device silicone rubber and present a plasma polymerized vinyl pyrrolidone (ppVP) coating which strongly decreases surface-activation of the blood complement system. We show that uncoated silicone and polystyrene...... surface. The ppVP surface is furthermore characterized physically and chemically using scanning electron microscopy (SEM), x-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR), which indicates preservation of chemical functionality by the applied plasma process. Overall, the pp...

  14. The impact of maternal plasma volume expansion and antihypertensive treatment with intravenous dihydralazine on fetal and maternal hemodynamics during pre-eclampsia: a clinical, echo-Doppler and viscometric study.

    Science.gov (United States)

    Boito, S M E; Struijk, P C; Pop, G A M; Visser, W; Steegers, E A P; Wladimiroff, J W

    2004-04-01

    To establish the effects of plasma volume expansion (PVE) followed by intravenous dihydralazine (DH) administration on maternal whole blood viscosity (WBV) and hematocrit, uteroplacental and fetoplacental downstream impedance and umbilical venous (UV) volume flow in pre-eclampsia. In 13 pre-eclamptic women maternal and fetal hemodynamics were established by means of combined measurement of maternal arterial blood pressure (BP), WBV, hematocrit and uterine artery (UtA) resistance index (RI) in addition to umbilical artery (UA) pulsatility index (PI) and UV volume flow obtained from UV vessel area and UV time-averaged flow velocity. In each woman all parameters were measured four times at baseline, after PVE, after DH and 24 h after the start of treatment. Maternal diastolic BP, hematocrit and WBV display a significant reduction after PVE. In the fetus UA PI decreases significantly whereas a significant increase in UV cross-sectional area was detected. After maternal DH administration, arterial systolic and diastolic BP and UA PI show a significant decrease compared with the measurements following PVE. At 24 h, only maternal systolic and diastolic BP display a significant further decrease. No significant changes were established for the UtA RI, UV time-averaged velocity and UV volume flow during the entire study period. During pre-eclampsia, maternal PVE followed by DH administration results in a significant reduction in maternal diastolic BP, maternal hematocrit and WBV. Maternal PVE is associated with a significant increase in UV cross-sectional area and a non-significant rise of 11% in UV volume flow. Maternal DH administration does not result in any change in UV cross-sectional area. However, UA PI decreases significantly after both PVE and DH treatment. Copyright 2004 ISUOG.

  15. Analysis of red cell mass and plasma volume in patients with polycythemia vera

    International Nuclear Information System (INIS)

    Nikolova, K.; Vassileva, D.

    2006-01-01

    Full text: Polycythemia vera (PV) was first described in 1892. The primary objective during the evaluation of erythrocytosis is to ascertain the presence or absence of PV. Because of prognostic and treatment differences, PV must be distinguished from relative polycythemia and secondary erythrocytosis. A retrospective analysis of RCM and plasma volume data are presented with special attention to different methods of RCM interpretation. A total 104 patients was studied (26 women and 78 men). Measurements of RCM and plasma volume were performed using chromium-51 labeled red cells. Results were expressed in millilitres by using the actual patient weight and using body surface area. There was a high prevalence of overweight or obesity in our population. However adipose tissue is relatively avascular, can lack precision of measurement of RCM in obese individuals. Pearson et al. showed that the results from 98% of males and 99% of females fall between ± 25% of the mean value at any given surface area. Using these limits as the reference range, we accepted the diagnosis of absolute erythrocytosis when an individual measured RCM is more than 25% above their predicted value

  16. Renal function and plasma volume following ultramarathon cycling.

    Science.gov (United States)

    Neumayr, G; Pfister, R; Hoertnagl, H; Mitterbauer, G; Prokop, W; Joannidis, M

    2005-01-01

    In recreational cyclists marathon cycling influences renal function only on a minimal scale. Respective information on extreme ultramarathon cycling in better trained athletes is not available. The objective was to evaluate the renal and haematological effects of ultraendurance cycling in the world's best ultramarathon cyclists. Creatinine (CR), urea, haemoglobin (Hb), haematocrit (Hct) and plasma volume (PV) were investigated in 16 male ultramarathon cyclists during the 1st Race Across the Alps in 2001 (distance: 525 km; cumulative altitude difference: 12,600 m). All renal functional parameters were normal pre-exercise. During the race serum CR, urea and uric acid rose significantly by 33, 97 % and 18 % (p training kilometers. The serum urea/CR ratio rose above 40 in 12 athletes (75 %). Mean fractional sodium excretion and fractional uric acid excretion fell below 0.5 % (p 0.40; p training.

  17. Severe Leptospirosis with Multiple Organ Failure Successfully Treated by Plasma Exchange and High-Volume Hemofiltration

    Directory of Open Access Journals (Sweden)

    Vincent Bourquin

    2011-01-01

    Full Text Available Background. Leptospirosis is a spirochetal zoonosis with complex clinical features including renal and liver failure. Case report. We report the case of a Swiss fisherman presenting with leptospirosis. After initial improvement, refractory septic shock and severe liver and kidney failure developed. The expected mortality was estimated at 90% with clinical scores. The patient underwent plasma exchanges and high-volume hemofiltration (HVHF with complete recovery of hepatic and kidney functions. Discussion. Plasma exchanges and HVHF may confer survival benefit on patients with severe leptospirosis, refractory septic shock, and multiple-organ failure.

  18. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy

    International Nuclear Information System (INIS)

    Burnett, T.L.; Kelley, R.; Winiarski, B.; Contreras, L.; Daly, M.; Gholinia, A.; Burke, M.G.; Withers, P.J.

    2016-01-01

    Ga + Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga + FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe + Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC–Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24 h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga + FIB milling WC–Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60 nA at 30 kV. Xe + PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. - Highlights: • The uptake of dual beam FIBs has been rapid but long milling times have limited imaged volumes to tens of micron dimensions. • Emerging plasma Xe + PFIB-SEM technology offers materials removal rates at least 60× greater than conventional Ga + FIB systems with comparable or less damage. • The

  19. Gray Matter Volume Decrease Distinguishes Schizophrenia From Bipolar Offspring During Childhood and Adolescence.

    Science.gov (United States)

    Sugranyes, Gisela; de la Serna, Elena; Romero, Soledad; Sanchez-Gistau, Vanessa; Calvo, Anna; Moreno, Dolores; Baeza, Inmaculada; Diaz-Caneja, Covadonga M; Sanchez-Gutierrez, Teresa; Janssen, Joost; Bargallo, Nuria; Castro-Fornieles, Josefina

    2015-08-01

    There is increasing support toward the notion that schizophrenia and bipolar disorder share neurodevelopmental underpinnings, although areas of divergence remain. We set out to examine gray matter volume characteristics of child and adolescent offspring of patients with schizophrenia or bipolar disorder comparatively. In this 2-center study, magnetic resonance structural neuroimaging data were acquired in 198 children and adolescents (aged 6-17 years): 38 offspring of patients with schizophrenia, 77 offspring of patients with bipolar disorder, and 83 offspring of community controls. Analyses of global brain volumes and voxel-based morphometry (using familywise error correction) were conducted. There was an effect of group on total cerebral gray matter volume (F = 3.26, p = .041), driven by a decrease in offspring of patients with schizophrenia relative to offspring of controls (p = .035). At a voxel-based level, we observed an effect of group in the left inferior frontal cortex/anterior insula (F = 14.7, p bipolar disorder (p bipolar disorder and offspring of controls in either global or voxel-based gray matter volumes. This first comparative study between offspring of patients with schizophrenia and bipolar disorder suggests that gray matter volume reduction in childhood and adolescence may be specific to offspring of patients with schizophrenia; this may index a greater neurodevelopmental impact of risk for schizophrenia relative to bipolar disorder during youth. Copyright © 2015 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  20. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B.

  1. Plasma volume shifts with immersion at rest and two exercise intensities.

    Science.gov (United States)

    Ertl, A C; Bernauer, E M; Hom, C A

    1991-04-01

    Eight men were studied to determine the effect of cycling exercise on plasma volume (PV) during water immersion to the xiphoid process (WIX). In all protocols the subjects were seated upright. After 30 min of rest, subjects were immersed in 34.5 degrees C water and seated on a cycling ergometer. During three 1 h WIX protocols, subjects either remained at rest (No Ex) or pedaled from minutes 20 to 30 at 38% (Ex1) or 62% (Ex2) of peak oxygen consumption (VO2peak). Hematocrit (Hct) and hemoglobin concentration [( Hb]) from venous blood samples were compared pre-WIX and at minutes 20, 30, 40, and 60. Percent change in PV (delta PV) was calculated from pre-WIX Hct and [Hb] within each protocol. Hct and [Hb] decreased after 20 min of resting WIX (P less than 0.017). In the No Ex protocol, there were no further significant changes in these variables, with delta PV values of +10.4% at minute 20 and at a peak of +13.5% at minute 40. In Ex1 and Ex2, cycling increased Hct and [Hb] (P less than 0.01, minute 30 vs No Ex), with delta PV values at minute 30 of +3.7% and -0.9%, respectively, vs +12.8% in No Ex. Minute 60 values between protocols were not significantly different (mean delta PV of +10.8 +/- 0.6% SD). The hemodilution associated with WIX was either partially or completely attenuated by cycling exercise; the degree of hemoconcentration was related to exercise intensity. The exercise-induced hemoconcentration was reversed by 30 min of resting WIX. Exercise during WIX appears to cause similar decreases in PV, as does exercise in air provided that postural hemoconcentration prior to exercise is not already maximal.

  2. Sleep apnea termination decreases cerebral blood volume: a near-infrared spectroscopy case study

    Science.gov (United States)

    Virtanen, Jaakko; Noponen, Tommi; Salmi, Tapani; Toppila, Jussi; Meriläinen, Pekka

    2009-07-01

    Medical near-infrared spectroscopy (NIRS) can be used to estimate cerebral haemodynamic changes non-invasively. Sleep apnea is a common sleep disorder where repetitive pauses in breathing decrease the quality of sleep and exposes the individual to various health problems. We have measured oxygenated and deoxygenated haemoglobin concentration changes during apneic events in sleep from the forehead of one subject using NIRS and used principal component analysis to extract extracerebral and cortical haemodynamic changes from NIRS signals. Comparison of NIRS signals with EEG, bioimpedance, and pulse oximetry data suggests that termination of apnea leads to decreases in cerebral blood volume and flow that may be related to neurological arousal via neurovascular coupling.

  3. Study of scattering cross section of a plasma column using Green's function volume integral equation method

    Science.gov (United States)

    Soltanmoradi, Elmira; Shokri, Babak

    2017-05-01

    In this article, the electromagnetic wave scattering from plasma columns with inhomogeneous electron density distribution is studied by the Green's function volume integral equation method. Due to the ready production of such plasmas in the laboratories and their practical application in various technological fields, this study tries to find the effects of plasma parameters such as the electron density, radius, and pressure on the scattering cross-section of a plasma column. Moreover, the incident wave frequency influence of the scattering pattern is demonstrated. Furthermore, the scattering cross-section of a plasma column with an inhomogeneous collision frequency profile is calculated and the effect of this inhomogeneity is discussed first in this article. These results are especially used to determine the appropriate conditions for radar cross-section reduction purposes. It is shown that the radar cross-section of a plasma column reduces more for a larger collision frequency, for a relatively lower plasma frequency, and also for a smaller radius. Furthermore, it is found that the effect of the electron density on the scattering cross-section is more obvious in comparison with the effect of other plasma parameters. Also, the plasma column with homogenous collision frequency can be used as a better shielding in contrast to its inhomogeneous counterpart.

  4. Decreased plasma concentrations of brain-derived neurotrophic factor (BDNF) in patients with functional hypothalamic amenorrhea.

    Science.gov (United States)

    Podfigurna-Stopa, Agnieszka; Casarosa, Elena; Luisi, Michele; Czyzyk, Adam; Meczekalski, Blazej; Genazzani, Andrea Riccardo

    2013-09-01

    Functional hypothalamic amenorrhea (FHA) is a non organic, secondary amenorrhea related to gonadotropin-releasing hormone pulsatile secretion impairment. Brain-derived neurotrophic factor (BDNF), a member of the neurotrophin family of survival-promoting molecules, plays an important role in the growth, development, maintenance and function of several neuronal systems. The aim of the study was the evaluation of plasma BDNF concentrations in patients with the diagnosis of FHA. We studied 85 subjects diagnosed with FHA who were compared with 10 healthy, eumenorrheic controls with normal body mass index. Plasma BDNF and serum luteinizing hormone, follicle-stimulating hormone and estradiol (E2) concentrations were measured by immunoenzymatic method (enzyme-linked immunosorbent assay). Significantly lower concentration of plasma BDNF was found in FHA patients (196.31 ± 35.26 pg/ml) in comparison to healthy controls (407.20 ± 25.71 pg/ml; p < 0.0001). In the control group, there was a strong positive correlation between plasma BDNF and serum E2 concentrations (r = 0.92, p = 0.0001) but in FHA group it was not found. Role of BDNF in FHA is not yet fully understood. There could be found studies concerning plasma BDNF concentrations in humans and animals in the literature. However, our study is one of the first projects which describes decreased plasma BDNF concentration in patients with diagnosed FHA. Therefore, further studies on BDNF in FHA should clarify the role of this peptide.

  5. Adenocarcinomas of the esophagus: Response to chemoradiotherapy is associated with decrease of metabolic tumor volume as measured on PET-CT

    International Nuclear Information System (INIS)

    Roedl, Johannes B.; Colen, Rivka R.; Holalkere, Nagaraj S.; Fischman, Alan J.; Choi, Noah C.; Blake, Michael A.

    2008-01-01

    Purpose: We determined whether evaluation of treatment response is feasible by measuring metabolic tumor volume parameters on 18F-FDG (Fluorodeoxyglucose) PET-CT (Positron emission tomography-Computed tomography). We compared the response evaluation based on metabolic tumor volume parameters to a histopathologic and clinical response evaluation (clinical response criteria: RECIST criteria = Response evaluation criteria in solid tumors, and WHO criteria = World health organization). Patients and methods: A total of 51 study subjects with adenocarcinomas (Type I due to Siewert classification) of the esophagus underwent PET-CT scans before and after neoadjuvant chemoradiotherapy. Tumor volume, maximum and mean standardized uptake values (SUV) were assessed before and after chemoradiotherapy. Furthermore, the total lesion glycolysis (TLG) was calculated by multiplying the tumor volume by the mean SUV of the volume. Clinical response evaluation was performed with endoscopic ultrasound and CT using RECIST and WHO criteria. The reference standard for treatment response was the postsurgical histopathology. Results: The decrease of tumor volume between the pre- and post-treatment PET-CT scans was a better predictor of histopathologic response and survival than the decrease of the SUV and of the clinical response evaluation based on RECIST and WHO criteria. The highest accuracy, however, was achieved when using the TLG for the identification of treatment responders. A decrease of the TLG by >78% between pre- and post-therapy scans predicted histopathologic response with a sensitivity and specificity of 91% and 93%, respectively. Conclusions: Tumor volume and TLG can be used to assess treatment response and survival in patients with esophageal adenocarcinoma

  6. Decreased plasma ADAMTS-13 activity as a predictor of postoperative bleeding in cyanotic congenital heart disease

    Directory of Open Access Journals (Sweden)

    Rosangela P.S. Soares

    2013-04-01

    Full Text Available OBJECTIVE: To analyze the preoperative plasma antigenic concentration and activity of von Willebrand factor and its main cleaving protease ADAMTS-13 in pediatric patients with cyanotic congenital heart disease undergoing surgical treatment and investigate possible correlations with postoperative bleeding. METHODS: Plasma antigenic concentrations (von Willebrand factor:Ag and ADAMTS-13:Ag were measured using enzyme-linked immunoassays. Collagen-binding assays were developed to measure biological activities (von Willebrand factor:collagen binding and ADAMTS-13 activity. The multimeric structure of von Willebrand factor was analyzed using Western immunoblotting. Demographic, diagnostic, and general and specific laboratory data and surgery-related variables were subjected to univariate, bivariate, and multivariate analysis for the prediction of postoperative bleeding. RESULTS: Forty-eight patients were enrolled, with ages ranging from 9 months to 7.6 years (median 2.5 years. The plasma concentrations of von Willebrand factor:Ag and ADAMTS-13:Ag were decreased by 65 and 82%, respectively, in the patients compared with the controls (p<0.001. An increased density of low-molecular-weight fractions of von Willebrand factor, which are suggestive of proteolytic degradation (p = 0.0081, was associated with decreased ADAMTS-13 activity, which was likely due to ADAMTS-13 consumption (71% of controls, p = 0.0029 and decreased von Willebrand factor:collagen binding (76% of controls, p = 0.0004. Significant postoperative bleeding occurred in 13 patients. The preoperative ADAMTS-13 activity of <64.6% (mean level for the group, preoperative activated partial thromboplastin time, and the need for cardiopulmonary bypass were characterized as independent risk factors for postoperative bleeding, with respective hazard ratios of 22.35 (95% CI 1.69 to 294.79, 1.096 (95% CI 1.016 to 1.183, and 37.43 (95% CI 1.79 to 782.73. CONCLUSION: Low plasma ADAMTS-13

  7. Sodium phenylbutyrate decreases plasma branched-chain amino acids in patients with urea cycle disorders.

    Science.gov (United States)

    Burrage, Lindsay C; Jain, Mahim; Gandolfo, Laura; Lee, Brendan H; Nagamani, Sandesh C S

    2014-01-01

    Sodium phenylbutyrate (NaPBA) is a commonly used medication for the treatment of patients with urea cycle disorders (UCDs). Previous reports involving small numbers of patients with UCDs have shown that NaPBA treatment can result in lower plasma levels of the branched-chain amino acids (BCAA) but this has not been studied systematically. From a large cohort of patients (n=553) with UCDs enrolled in the Longitudinal Study of Urea Cycle Disorders, a collaborative multicenter study of the Urea Cycle Disorders Consortium, we evaluated whether treatment with NaPBA leads to a decrease in plasma BCAA levels. Our analysis shows that NaPBA use independently affects the plasma BCAA levels even after accounting for multiple confounding covariates. Moreover, NaPBA use increases the risk for BCAA deficiency. This effect of NaPBA seems specific to plasma BCAA levels, as levels of other essential amino acids are not altered by its use. Our study, in an unselected population of UCD subjects, is the largest to analyze the effects of NaPBA on BCAA metabolism and potentially has significant clinical implications. Our results indicate that plasma BCAA levels should to be monitored in patients treated with NaPBA since patients taking the medication are at increased risk for BCAA deficiency. On a broader scale, these findings could open avenues to explore NaPBA as a therapy in maple syrup urine disease and other common complex disorders with dysregulation of BCAA metabolism. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Increased CSF-BACE1 activity associated with decreased hippocampus volume in Alzheimer's disease.

    LENUS (Irish Health Repository)

    Ewers, Michael

    2012-02-01

    The enzyme beta-secretase (BACE1) is essentially involved in the production of cerebral amyloidogenic pathology in Alzheimer\\'s disease (AD). The measurement of BACE1 activity in cerebrospinal fluid (CSF) has been reported, which may render CSF measurement of BACE1 a potential biomarker candidate of AD. In order to investigate whether BACE1 protein activity is correlated with regional brain atrophy in AD, we investigated the association between CSF levels of BACE1 and MRI-assessed hippocampus volume in patients with AD (n = 30). An increase in CSF-BACE1 activity was associated with decreased left and right hippocampus volume corrected for global head volume in the AD patients. Boot-strapped regression analysis showed that increased CSF levels of BACE1 activity were associated with increased CSF concentration of total tau but not amyloid-beta1-42 in AD. White matter hyperintensities did not influence the results. BACE1 activity and protein levels were significantly increased in AD compared to 19 elderly healthy controls. Thus, the CSF biomarker candidate of BACE1 activity was associated with hippocampus atrophy in AD in a robust manner and may reflect neurotoxic amyloid-beta-related processes.

  9. Effect of focal irradiation on plasma kallikrein activity in tumor bearing rats

    International Nuclear Information System (INIS)

    Makoyo, P.O.Z.R.; West, W.L.

    1977-01-01

    The activated plasma kallikrein from tumor bearing rats before and after focal irradiation of the hind limbs was measured by the hydrolysis of 0.015M N-(p-toluene sulfonyl)-L arginine methyl ester (TAME). Blood was collected from abdominal aorta of rats anesthetized with diethyl ether into plastic tubes containing 1 volume of 3.8 percent sodium citrate for each 9 volumes. Plasma was isolated by centrifugation (2000 g) at 4 0 C. Small pieces of minced tumor tissue were inserted in a trochar and inoculated in the hind limbs of the rats. Morris hepatomas 7777 and 3924A were transplanted subcutaneously over the hind legs while Walker 256 tumor was transplanted intramuscularly in the hind limbs. Plasma kallikrein (μm TAME utilized/ml/hr) was decreased in three different groups of tumor bearing rats: Walker tumor from 207 +- 34 to 114 +- 30 Hepatoma 7777 from 219 +- 13 to 106 +- 3 and Hepatoma 3924A from 227 +- 7 to 133 +- 5. Two hours after focal irradiation (1000 R) plasma kallikrein decreased further in Walker tumor and hepatoma 7777 to 55 +- 5 and 96 +- 3.6 respectively. The plasma of tumor bearing rats becomes deficient in kallikrein at about the time metastases may be identified. The acute fall in plasma kallikrein is consistent with the overall stress mechanism

  10. Two Years of Cinacalcet Hydrochloride Treatment Decreased Parathyroid Gland Volume and Serum Parathyroid Hormone Level in Hemodialysis Patients With Advanced Secondary Hyperparathyroidism.

    Science.gov (United States)

    Yamada, Shunsuke; Tokumoto, Masanori; Taniguchi, Masatomo; Toyonaga, Jiro; Suehiro, Takaichi; Eriguchi, Rieko; Fujimi, Satoru; Ooboshi, Hiroaki; Kitazono, Takanari; Tsuruya, Kazuhiko

    2015-08-01

    The long-term effect of cinacalcet hydrochloride treatment on parathyroid gland (PTG) volume has been scarcely investigated in patients with moderate to advanced secondary hyperparathyroidism (SHPT). The present study was a prospective observational study to determine the effect of cinacalcet treatment on PTG volume and serum biochemical parameters in 60 patients with renal SHPT, already treated with intravenous vitamin D receptor activator (VDRA). Measurement of biochemical parameters and PTG volumes were performed periodically, which were analyzed by stratification into tertiles across the baseline parathyroid hormone (PTH) level or PTG volume. We also determined the factors that can estimate the changes in PTG volume and the achievement of the target PTH range by multivariable analyses. Two years of cinacalcet treatment significantly decreased the serum levels of PTH, calcium, and phosphate, followed by the improvement of achieving the target ranges for these parameters recommended by the Japanese Society for Dialysis Therapy. Cinacalcet decreased the maximal and total PTG volume by about 30%, and also decreased the serum PTH level independent of the baseline serum PTH level and PTG volume. Ten out of 60 patients showed 30% increase in maximal PTG after 2 years. Multivariable analysis showed that patients with nodular PTG at baseline and patients with higher serum calcium and PTH levels at 1 year were likely to exceed the target range of PTH at two years. In conclusion, cinacalcet treatment with intravenous VDRA therapy decreased both PTG volume and serum intact PTH level, irrespective of the pretreatment PTG status and past treatment history. © 2015 The Authors. Therapeutic Apheresis and Dialysis © 2015 International Society for Apheresis.

  11. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, T.L. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Kelley, R. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Winiarski, B. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Contreras, L. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Daly, M.; Gholinia, A.; Burke, M.G. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Withers, P.J., E-mail: P.J.Withers@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); BP International Centre for Advanced Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2016-02-15

    Ga{sup +} Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga{sup +} FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe{sup +} Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC–Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24 h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga{sup +} FIB milling WC–Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60 nA at 30 kV. Xe{sup +} PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. - Highlights: • The uptake of dual beam FIBs has been rapid but long milling times have limited imaged volumes to tens of micron dimensions. • Emerging plasma Xe{sup +} PFIB-SEM technology offers materials removal rates at least 60× greater than conventional Ga{sup +} FIB systems with

  12. Plasma diagnostics package. Volume 1: OSS-1 section

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (1) of the Plasma Diagnostics Package (PDP) final science report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-3 as a part of the Office of Space Science first payload (OSS-1). This work was performed during the period of launch, March 22, l982, through June 30, l983. During this period the primary data reduction effort consisted of processing summary plots of the data received by the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). The scientific analyses during the performance period consisted of general studies which incorporated the results of several of the PDP's instruments, detailed studies which concentrated on data from only one or two of the instruments, and joint studies of beam-plasma interactions with the OSS-1 Fast Pulse Electron Generator (FPEG) of the Vehicle Charging and Potential Investigation (VCAP). Internal reports, published papers and oral presentations which involve PDP/OSS-1 data are listed in Sections 3 and 4. A PDP/OSS-1 scientific results meeting was held at the University of Iowa on April 19-20, 1983. This meeting was attended by most of the PDP and VCAP investigators and provided a forum for discussing and comparing the various results, particularly with regard to the shuttle orbiter environment. One of the most important functional objectives of the PDP on OSS-1 was to characterize the orbiter environment.

  13. Increased ANF secretion after volume expansion is preserved in rats with heart failure

    International Nuclear Information System (INIS)

    Chien, Young Wei; Barbee, R.W.; MacPhee, A.L.; Frohlich, E.D.; Trippodo, N.C.

    1988-01-01

    To examine whether the failing heart has reached a maximal capacity to increase plasma atrial natriuretic factor (ANF) concentration, the change in plasma immunoreactive ANF, measured by radioimmunoassay level due to acute blood volume expansion was determined in conscious rats with chronic heart failure. Varying degrees of myocardial infarction and thus heart failure were induced by coronary artery ligation 3 wk before study. Compared with controls, infarcted rats had decreases in mean arterial pressure cardiac index, renal blood flow, and peak left ventricle-developed pressure after aortic occlusion, and increases in central venous pressure, left ventricular end-diastolic pressure, total peripheral resistance, plasma ANF level. Plasma ANF was correlated with infarct size, cardiac filling pressures, and left ventricle pressure-generating ability. At 5 min after 25% blood volume expansion, plasma ANF in rats with heart failure increased by 2,281 ± 345 pg/ml; the magnitude of the changes in circulating ANF and hemodynamic measurements was similar in controls. The results suggest that plasma ANF level can be used as a reliable index of the severity of heart failure, and that the capacity to increase plasma ANF concentration after acute volume expansion is preserved in rats with heart failure. There was no evidence of a relative deficiency of circulating ANF in this model of heart failure

  14. Apparent CBF decrease with normal aging due to partial volume effects: MR-based partial volume correction on CBF SPECT.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Goto, Ryoi; Nakagawa, Manabu; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2005-06-01

    Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT scanner, before and after partial volume correction (PVC) using magnetic resonance (MR) imaging. Forty-four healthy subjects (29 males and 15 females; age range, 27-64 y; mean age, 50.0 +/- 9.8 y) participated. Each MR image was segmented to yield grey and white matter images and coregistered to a corresponding SPECT image, followed by convolution to approximate the SPECT spatial resolution. PVC-SPECT images were produced using the convoluted grey matter MR (GM-MR) and white matter MR images. The age and gender effects were assessed using SPM99. Decreases with age were detected in the anterolateral prefrontal cortex and in areas along the lateral sulcus and the lateral ventricle, bilaterally, in the GM-MR images and the SPECT images. In the PVC-SPECT images, decreases in CBF in the lateral prefrontal cortex lost their statistical significance. Decreases in CBF with age found along the lateral sulcus and the lateral ventricle, on the other hand, remained statistically significant, but observation of the spatially normalized MR images suggests that these findings are associated with the dilatation of the lateral sulcus and lateral ventricle, which was not completely compensated for by the spatial normalization procedure. Our present study demonstrated that age effects on CBF in healthy subjects could reflect morphological differences with age in grey matter.

  15. Modification of the Steel Surface Treated by a Volume Discharge Plasma in Nitrogen at Atmospheric Pressure

    Science.gov (United States)

    Erofeev, M. V.; Shulepov, M. A.; Ivanov, Yu. F.; Oskomov, K. V.; Tarasenko, V. F.

    2016-03-01

    Effect of volume discharge plasma initiated by an avalanche electron beam on the composition, structure, and properties of the surface steel layer is investigated. Voltage pulses with incident wave amplitude up to 30 kV, full width at half maximum of about 4 ns, and wave front of about 2.5 ns were applied to the gap with an inhomogeneous electric field. Changes indicating the hardening effect of the volume discharge initiated by an avalanche electron beam are revealed in St3-grade steel specimens treated by the discharge of this type.

  16. Automated processing of whole blood samples into microliter aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  17. Chronic activation of plasma renin is log-linearly related to dietary sodium and eliminates natriuresis in response to a pulse change in total body sodium

    DEFF Research Database (Denmark)

    Kjolby, Mads; Bie, Peter

    2008-01-01

    rate, urine flow, plasma potassium, and plasma renin activity did not change. The results indicate that sodium excretion is controlled by neurohumoral mechanisms that are quite resistant to acute changes in plasma volume and colloid osmotic pressure and are not down-regulated within 2 h. With previous......Cl administration increased PV (+6.3-8.9%) and plasma sodium concentration (~2%) and decreased plasma protein concentration (-6.4-8.1%). Plasma ANG II and aldosterone concentrations decreased transiently. Potassium excretion increased substantially. Sodium excretion, arterial blood pressure, glomerular filtration...

  18. Prostate-specific antigen lowering effect of metabolic syndrome is influenced by prostate volume.

    Science.gov (United States)

    Choi, Woo Suk; Heo, Nam Ju; Paick, Jae-Seung; Son, Hwancheol

    2016-04-01

    To investigate the influence of metabolic syndrome on prostate-specific antigen levels by considering prostate volume and plasma volume. We retrospectively analyzed 4111 men who underwent routine check-ups including prostate-specific antigen and transrectal ultrasonography. The definition of metabolic syndrome was based on the modified Adult Treatment Panel III criteria. Prostate-specific antigen mass density (prostate-specific antigen × plasma volume / prostate volume) was calculated for adjusting plasma volume and prostate volume. We compared prostate-specific antigen and prostate-specific antigen mass density levels of participants with metabolic syndrome (metabolic syndrome group, n = 1242) and without metabolic syndrome (non-prostate-specific antigen metabolic syndrome group, n = 2869). To evaluate the impact of metabolic syndrome on prostate-specific antigen, linear regression analysis for the natural logarithm of prostate-specific antigen was used. Patients in the metabolic syndrome group had significantly older age (P prostate volume (P prostate-specific antigen (non-metabolic syndrome group vs metabolic syndrome group; 1.22 ± 0.91 vs 1.15 ± 0.76 ng/mL, P = 0.006). Prostate-specific antigen mass density in the metabolic syndrome group was still significantly lower than that in the metabolic syndrome group (0.124 ± 0.084 vs 0.115 ± 0.071 μg/mL, P = 0.001). After adjusting for age, prostate volume and plasma volume using linear regression model, the presence of metabolic syndrome was a significant independent factor for lower prostate-specific antigen (prostate-specific antigen decrease by 4.1%, P = 0.046). Prostate-specific antigen levels in patients with metabolic syndrome seem to be lower, and this finding might be affected by the prostate volume. © 2016 The Japanese Urological Association.

  19. Role of BK channels in the apoptotic volume decrease in native eel intestinal cells

    DEFF Research Database (Denmark)

    Lionetto, Maria Giulia; Giordano, Maria Elena; Calisi, Antonio

    2010-01-01

    High conductance Ca(+)-activated K(+) channels (BK channels) have previously been demonstrated in the eel intestine. They are specifically activated following a hypotonic stress and sustain Regulatory Volume Decrease (RVD). The aim of the present work was to address the possible role...... enterocytes that BK channels, which are involved in RVD in these cells, plays also a crucial role in the AVD process and in the progression of apoptosis....

  20. The loss-of-function disease-mutation G301R in the Na+/K+-ATPase α2 isoform decreases lesion volume and improves functional outcome after acute spinal cord injury in mice

    DEFF Research Database (Denmark)

    Ellman, Ditte; Isaksen, Toke Jost; Lund, Minna

    2017-01-01

    BACKGROUND: The Na(+)/K(+)-ATPases are transmembrane ion pumps important for maintenance of ion gradients across the plasma membrane that serve to support multiple cellular functions, such as membrane potentials, regulation of cellular volume and pH, and co-transport of signaling transmitters...... lesion volume compared to littermate controls (α 2(+/+) ) 7 days after SCI. The protein level of the α1 isoform was significantly increased, in contrast to the α3 isoform that significantly decreased 3 days after SCI in both α 2(+/G301R) and α 2(+/+) mice. The level of the α2 isoform was significantly...... as no apparent differences were observed in location and activation of CD45 and F4/80 positive microglia and infiltrating leukocytes. CONCLUSION: Our proof of concept study demonstrates that reduced expression of the α2 isoform in the spinal cord is protective following SCI. Importantly, the BMS and lesion...

  1. Plasma Lp-PLA2 mass and apoB-lipoproteins that carry Lp-PLA2 decrease after sodium

    NARCIS (Netherlands)

    Constantinides, Alexander; Kerstens, Michiel N.; Dikkeschei, Bert D.; van Pelt, L. Joost; Tellis, Constantinos C.; Tselepis, Alexandros D.; Dullaart, Robin P. F.

    2012-01-01

    Eur J Clin Invest 2012; 42 (11): 12351243 Abstract Background Lipoprotein-associated phospholipase A2 (Lp-PLA2) is a novel cardiovascular risk marker, which is predominantly complexed to apolipoprotein (apo) B-containing lipoproteins in human plasma. As increasing dietary sodium intake may decrease

  2. Effect of naftopidil on brain noradrenaline-induced decrease in arginine-vasopressin secretion in rats

    Directory of Open Access Journals (Sweden)

    Masaki Yamamoto

    2016-09-01

    Full Text Available Naftopidil, an α1-adrenoceptor antagonist, has been shown to inhibit nocturnal polyuria in patients with lower urinary tract symptom. However, it remains unclear how naftopidil decreases nocturnal urine production. Here, we investigated the effects of naftopidil on arginine-vasopressin (AVP plasma level and urine production and osmolality in rats centrally administered with noradrenaline (NA. NA (3 or 30 μg/kg was administered into the left ventricle (i.c.v. of male Wistar rats 3 h after naftopidil pretreatment (10 or 30 mg/kg, i.p.. Blood samples were collected from the inferior vena cava 1 h after NA administration or 4 h after peritoneal administration of naftopidil; plasma levels of AVP were assessed by ELISA. Voiding behaviors of naftopidil (30 mg/kg, i.p.-administered male Wistar rats were observed during separate light- and dark cycles. Administration of NA decreased plasma AVP levels and elevated urine volume, which were suppressed by systemic pretreatment with naftopidil (30 mg/kg, i.p.. Urine osmolality decreased 1 h after NA administration. However, naftopidil by itself had no effect on plasma AVP levels or urodynamic parameters during light- and dark cycles. Our findings suggest that systemic administration of naftopidil could prevent central noradrenergic nervous system-mediated decline in AVP secretion and increase in urine production in rats.

  3. Maternal nutritional status in early pregnancy is associated with body water and plasma volume changes in a pregnancy cohort in rural Bangladesh.

    Science.gov (United States)

    Gernand, Alison D; Christian, Parul; Schulze, Kerry J; Shaikh, Saijuddin; Labrique, Alain B; Shamim, Abu Ahmed; West, Keith P

    2012-06-01

    Plasma volume expansion has been associated with fetal growth. Our objective was to examine the associations between maternal nutritional status in early pregnancy and extracellular water (ECW), total body water (TBW), and percentage plasma volume change across pregnancy. In a subsample of 377 pregnant women participating in a cluster-randomized trial of micronutrient supplementation, hemoglobin, hematocrit, and multi-frequency bioelectrical impedance were measured at ~10, 20, and 32 wk of gestation. In early pregnancy, women were short (mean ± SD, 148.9 ± 5.3 cm) and thin (19.5 ± 2.5 kg/m(2)). In mixed-effects multiple regression models, a 1-unit higher BMI at ~10 wk was associated with higher ECW and TBW (0.27 and 0.66 kg per kg/m(2), respectively; P pregnancy BMI was negatively associated with gains in ECW and TBW (-0.06 and -0.14 kg per kg/m(2), respectively; P pregnancy have lower ECW and TBW in early, mid, and late pregnancy and lower late pregnancy plasma volume expansion, potentially increasing risk of fetal growth restriction.

  4. Quiescent plasma machine for plasma investigation

    International Nuclear Information System (INIS)

    Ferreira, J.L.

    1993-01-01

    A large volume quiescent plasma device is being developed at INPE to study Langmuir waves and turbulence generated by electron beams (E b ≤ 500 e V) interacting with plasma. This new quiescent plasma machine was designed to allow the performance of several experiments specially those related with laboratory space plasma simulation experiments. Current-driven instabilities and related phenomena such as double-layers along magnetic field lines are some of the many experiments planned for this machine. (author)

  5. Plasma diagnostics package. Volume 2: Spacelab 2 section, part A

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, l985, through June 30, l988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). The scientific analyses during the performance period consisted of follow-up studies of shuttle orbiter environment and orbiter/ionosphere interactions and various plasma particle and wave studies which dealt with data taken when the PDP was on the Remote Manipulator System (RMS) arm and when the PDP was in free flight. Of particular interest during the RMS operations and free flight were the orbiter wake studies and joint studies of beam/plasma interactions with the SL-2 Fast Pulse Electron Generator (FPEG) of the Vehicle Charging and Potential Investigation (VCAP). Internal reports, published papers and presentations which involve PDP/SL-2 data are listed in Sections 3 and 4. A PDP/SL-2 scientific results meeting was held at the University of Iowa on June 10, l986. This meeting was attended by most of the PDP and VCAP investigators and provided a forum for discussing and comparing the various results, particularly with regard to the PDP free flight.

  6. Mathematical simulation of water distillation column for decreasing volume of tritiated water

    International Nuclear Information System (INIS)

    Kinoshita, Masahiro; Naruse, Yuji

    1981-12-01

    Water distillation is an attractive method for decreasing volume of the tritiated water produced by operation of tritium facilities. The tritiated water is continuously fed to a column and it is separated into two streams. The top stream is discarded to the environment after addition of sufficient amount of uncontaminated water. The bottom stream is further treated for solidification and capsulation. The tridiagonal matrix method proved to provide surprisingly rapid convergences of the calculations. The concentration of deuterium naturally contained in the tritiated water is higher than the tritium concentration, but it was verified that presence of HDO can be ignored in the calculation. (author)

  7. Decreased plasma levels of soluble CD18 link leukocyte infiltration with disease activity in spondyloarthritis

    DEFF Research Database (Denmark)

    Kragstrup, Tue Wenzel; Jalilian, Babak; Hvid, Malene

    2014-01-01

    of arthritis patients to have anti-inflammatory functions. Here, we study the mechanisms for these alterations and their association with SpA disease activity. METHODS: Plasma levels of sCD18 in a study population with 84 SpA patients and matched healthy controls were analyzed with a time resolved......A patients compared with healthy volunteers (P levels in the HLA-B27-positive subgroup (P levels exhibited an inverse correlation with the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) (P level of morning...... immunoflourometric assay (TRIFMA). Binding of sCD18 to endothelial cells and fibroblast-like synovial cells (FLS) was studied with confocal microscopy. Shedding of CD18 from peripheral blood mononuclear cells (PBMC) was studied with flow cytometry and TRIFMA. RESULTS: Plasma levels of sCD18 were decreased in Sp...

  8. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect.

    Science.gov (United States)

    Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L

    2013-08-01

    Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Open loop control of filament heating power supply for large volume plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Sugandhi, R., E-mail: ritesh@ipr.res.in [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Srivastava, P.K.; Sanyasi, A.K. [Homi Bhabha National Institute, Mumbai 400094 (India); Srivastav, Prabhakar [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Awasthi, L.M., E-mail: kushagra.lalit@gmail.com [Institute for Plasma Research, Gandhinagar, Gujarat 382428 (India); Homi Bhabha National Institute, Mumbai 400094 (India); Mattoo, S.K. [Homi Bhabha National Institute, Mumbai 400094 (India)

    2017-02-15

    A power supply (20 V, 10 kA) for powering the filamentary cathode has been procured, interfaced and integrated with the centralized control system of Large Volume Plasma Device (LVPD). Software interface has been developed on the standard Modbus RTU communication protocol. It facilitates the dashboard for configuration, on line status monitoring, alarm management, data acquisition, synchronization and controls. It has been tested for stable operation of the power supply for the operational capabilities. The paper highlights the motivation, interface description, implementation and results obtained.

  10. Open loop control of filament heating power supply for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, R.; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2017-01-01

    A power supply (20 V, 10 kA) for powering the filamentary cathode has been procured, interfaced and integrated with the centralized control system of Large Volume Plasma Device (LVPD). Software interface has been developed on the standard Modbus RTU communication protocol. It facilitates the dashboard for configuration, on line status monitoring, alarm management, data acquisition, synchronization and controls. It has been tested for stable operation of the power supply for the operational capabilities. The paper highlights the motivation, interface description, implementation and results obtained.

  11. The correlation of plasma omentin-1 with insulin resistance in non-obese polycystic ovary syndrome.

    Science.gov (United States)

    Yang, Hai-Yan; Ma, Yan; Lu, Xin-Hong; Liang, Xing-Huan; Suo, Ying-Jun; Huang, Zhen-Xing; Lu, De-Cheng; Qin, Ying-Fen; Luo, Zuo-Jie

    2015-10-01

    Aberrant circulating adipokines are considered to be related to the pathological mechanism of polycystic ovary syndrome (PCOS). This study aims to evaluate the relationship between plasma omentin-1 levels, metabolic and hormonal parameters in the setting of non-obese Chinese women with PCOS. This was a case-controlled, cross-sectional study of 153 non-obese (BMIovary volume were analyzed in all subjects. Plasma omentin-1 levels of non-obese PCOS individuals were significantly lower than in healthy non-obese controls. Body Mass Index (BMI), homeostasis model of assessment for insulin resistance index (HOMA-IR), levels of testosterone, luteinizing hormone (LH) and follicle-stimulating hormone (FSH), LH/FSH ratio and ovary volume (OV) were significantly higher in subjects with PCOS than controls. In the HOMA-IR stratified subgroups, PCOS individuals with insulin resistance had lower omentin-1 than those without insulin resistance after BMI adjustment. Omentin-1 was negatively correlated with BMI, HOMA-IR and fasting insulin. Multiple linear regressions revealed that BMI contributed to omentin-1 levels. Ovary volume was negatively correlated to HOMA-IR but had no correlation with omentin-1. Plasma omentin-1 concentrations were decreased in the non-obese PCOS group. Insulin resistance could further decrease plasma omentin-1 in non-obese individuals with PCOS independent of BMI status. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  12. Quantitative changes in adipocyte plasma membrane in response to nutritional manipulations

    International Nuclear Information System (INIS)

    Lewis, D.S.; Masoro, E.J.; Yu, B.P.

    1981-01-01

    The effects of changes in adipocyte size and the effects of nutritional manipulations on the quantity of plasma membrane per adipocyte were investigated. A method for estimating the quantity of plasma membrane was developed based on the specific labeling of adipocyte plasma membrane protein with the nonpermeable labeling agent 125I-labeled diazotized diiodosulfanilic acid. By studying rats (ranging in age from 50 to 125 days) fed a standard laboratory chow or a low fat diet or a high fat diet, a wide range of mean fat cell sizes was obtained. It was found that as the volume of the fat cell increased, the amount of plasma membrane increased in a linear fashion and that this linear relationship had the same slope whether the size of the adipocyte increased slowly with age or rapidly in response to a high fat diet. In contrast, fasting for up to 3 days caused a marked decrease in the mean volume of the adipocytes, but either no change or much less change in the amount of plasma membrane per cell than would have been predicted from the linear relationship between adipocytes, but either no change or much less change in the amount of plasma membrane per cell than would have been predicted form the linear relationship between adipocyte volume and amount of plasma membrane per cell obtained with fed rats, i.e., adipocytes from fasted rats contain more plasma membrane per cell than do fat cells of the same size from fed rats. Neither feeding a high fat diet nor fasting caused detectable changes in the protein and lipid composition of the adipocyte plasma membrane

  13. Plasma processing for VLSI

    CERN Document Server

    Einspruch, Norman G

    1984-01-01

    VLSI Electronics: Microstructure Science, Volume 8: Plasma Processing for VLSI (Very Large Scale Integration) discusses the utilization of plasmas for general semiconductor processing. It also includes expositions on advanced deposition of materials for metallization, lithographic methods that use plasmas as exposure sources and for multiple resist patterning, and device structures made possible by anisotropic etching.This volume is divided into four sections. It begins with the history of plasma processing, a discussion of some of the early developments and trends for VLSI. The second section

  14. Renal effects of carprofen and etodolac in euvolemic and volume-depleted dogs.

    Science.gov (United States)

    Surdyk, Kathryn K; Sloan, Dawn L; Brown, Scott A

    2012-09-01

    To determine the effects of carprofen and etodolac on renal function in euvolemic dogs and dogs with extracellular fluid volume depletion induced via administration of furosemide. 12 female Beagles. Dogs received a placebo, furosemide, carprofen, etodolac, furosemide and carprofen, and furosemide and etodolac. The order in which dogs received treatments was determined via a randomization procedure. Values of urine specific gravity, various plasma biochemical variables, glomerular filtration rate (GFR [urinary clearance of creatinine]), and renal plasma flow (urinary clearance of para-aminohippuric acid) were determined before and after 8 days of drug administration. A washout time of approximately 12 days was allowed between treatment periods. Administration of furosemide, furosemide and carprofen, and furosemide and etodolac caused changes in urine specific gravity and values of plasma biochemical variables. Administration of carprofen or etodolac alone did not have a significant effect on renal plasma flow or GFR. Concurrent administration of furosemide and carprofen or furosemide and etodolac caused a significant decrease in GFR. After 12-day washout periods, mean values of GFR were similar to values before drug administration for all treatments. Results indicated GFR decreased after 8 days of concurrent administration of furosemide and carprofen or furosemide and etodolac to dogs. Administration of preferential cyclooxygenase-2 inhibitors to dogs with extracellular fluid volume depletion or to dogs treated with diuretics may transiently impair renal function.

  15. Blood Volume, Plasma Volume and Circulation Time in a High-Energy-Demand Teleost, the Yellowfin Tuna (Thunnus Albacares)

    DEFF Research Database (Denmark)

    Brill, R.W.; Cousins, K.L.; Jones, D.R.

    1998-01-01

    We measured red cell space with 51Cr-labeled red blood cells, and dextran space with 500 kDa fluorescein-isothiocyanate-labeled dextran (FITC-dextran), in two groups of yellowfin tuna (Thunnus albacares). Red cell space was 13.8+/-0.7 ml kg-1 (mean +/- s.e.m.) Assuming a whole- body hematocrit...... for albacore (Thunnus alalunga, 82-197 ml kg-1). Plasma volume within the primary circulatory system (calculated from the 51Cr-labeled red blood cell data) was 32.9+/-2.3 ml kg-1. Dextran space was 37.0+/-3.7 ml kg-1. Because 500 kDa FITC-dextran appeared to remain within the vascular space, these data imply...

  16. Pharmacokinetic profile of voriconazole in a critically ill patient on therapeutic plasma exchange

    NARCIS (Netherlands)

    Spriet, I.; Bruggemann, R.J.M.; Annaert, P.; Meersseman, P.; Wijngaerden, E. van; Lagrou, K.; Willems, L.

    2013-01-01

    BACKGROUND: Extracorporeal removal of drugs during therapeutic plasma exchange (TPE) can lead to decreased efficacy, as shown in several reports discussing altered pharmacokinetics (PKs) of antibiotics during TPE. In particular, drugs with a low volume of distribution or a high protein binding are

  17. Expansion of the cathode spot and generation of shock waves in the plasma of a volume discharge in atmospheric-pressure helium

    International Nuclear Information System (INIS)

    Omarov, O. A.; Kurbanismailov, V. S.; Arslanbekov, M. A.; Gadzhiev, M. Kh.; Ragimkhanov, G. B.; Al-Shatravi, Ali J. G.

    2012-01-01

    The expansion of the cathode spot and the generation of shock waves during the formation and development of a pulsed volume discharge in atmospheric-pressure helium were studied by analyzing the emission spectra of the cathode plasma and the spatiotemporal behavior of the plasma glow. The transition of a diffuse volume discharge in a centimeter-long gap into a high-current diffuse mode when the gas pressure increased from 1 to 5 atm and the applied voltage rose from the statistical breakdown voltage to a 100% overvoltage was investigated. Analytical expressions for the radius of the cathode spot and its expansion velocity obtained in the framework of a spherically symmetric model agree satisfactorily with the experimental data.

  18. Atmospheric pressure microwave plasma system with ring waveguide

    International Nuclear Information System (INIS)

    Liu Liang; Zhang Guixin; Zhu Zhijie; Luo Chengmu

    2007-01-01

    Some scientists used waveguide as the cavity to produce a plasma jet, while large volume microwave plasma was relatively hard to get in atmospheric pressure. However, a few research institutes have already developed devices to generate large volume of atmospheric pressure microwave plasma, such as CYRANNUS and SLAN series, which can be widely applied. In this paper, present a microwave plasma system with ring waveguide to excite large volume of atmospheric pressure microwave plasma, plot curves on theoretical disruption electric field of some working gases, emulate the cavity through software, measure the power density to validate and show the appearance of microwave plasma. At present, large volume of argon and helium plasma have already been generated steadily by atmospheric pressure microwave plasma system. This research can build a theoretical basis of microwave plasma excitation under atmospheric pressure and will be useful in study of the device. (authors)

  19. Mean platelet volume is decreased in adults with active lupus disease

    Directory of Open Access Journals (Sweden)

    Guillermo Delgado-García

    Full Text Available ABSTRACT Background: Only a few biomarkers are available for assessing disease activity in systemic lupus erythematosus (SLE. Mean platelet volume (MPV has been recently studied as an inflammatory biomarker. It is currently unclear whether MPV may also play a role as a biomarker of disease activity in adult patients with SLE. Objective: We investigated the association between MPV and disease activity in adult patients with SLE. Methods: In this retrospective study, we compared two groups of adult patients divided according to disease activity (36 per group. Subjects were age- and gender-matched. Results: MPV was significantly decreased with respect to those of inactive patients (7.16 ± 1.39 vs. 8.16 ± 1.50, p = 0.005. At a cutoff level of 8.32 fL, MPV has a sensitivity of 86% and a specificity of 41% for the detection of disease activity. A modest positive correlation was found between MPV and albumin (r = 0.407, p = 0.001, which in turn is inversely associated with disease activity. Conclusions: In summary, MPV is decreased in adult patients with active lupus disease, and positively correlated with albumin, another biomarker of disease activity. Prospective studies are needed to evaluate the prognostic value of this biomarker.

  20. Mean platelet volume is decreased in adults with active lupus disease.

    Science.gov (United States)

    Delgado-García, Guillermo; Galarza-Delgado, Dionicio Ángel; Colunga-Pedraza, Iris; Borjas-Almaguer, Omar David; Mandujano-Cruz, Ilse; Benavides-Salgado, Daniel; Martínez-Granados, Rolando Jacob; Atilano-Díaz, Alexandro

    Only a few biomarkers are available for assessing disease activity in systemic lupus erythematosus (SLE). Mean platelet volume (MPV) has been recently studied as an inflammatory biomarker. It is currently unclear whether MPV may also play a role as a biomarker of disease activity in adult patients with SLE. We investigated the association between MPV and disease activity in adult patients with SLE. In this retrospective study, we compared two groups of adult patients divided according to disease activity (36 per group). Subjects were age- and gender-matched. MPV was significantly decreased with respect to those of inactive patients (7.16±1.39 vs. 8.16±1.50, p=0.005). At a cutoff level of 8.32fL, MPV has a sensitivity of 86% and a specificity of 41% for the detection of disease activity. A modest positive correlation was found between MPV and albumin (r=0.407, p=0.001), which in turn is inversely associated with disease activity. In summary, MPV is decreased in adult patients with active lupus disease, and positively correlated with albumin, another biomarker of disease activity. Prospective studies are needed to evaluate the prognostic value of this biomarker. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  1. Production and loss of H- and D- in the volume of a plasma

    International Nuclear Information System (INIS)

    Hamilton, G.W.; Bacal, M.

    1981-01-01

    The study of the production and loss of negative ions, H - and D - , in the volume of a plasma has received considerable attention since the measurement of anomalously high densities of H - in 1977. The most probable mechanism for production is dissociative attachment (DA) to vibrationally highly-excited hydrogen molecules. New diagnostics developed for this purpose are photodetachment and the extension of coherent anti-Stokes Raman scattering (CARS) systems to the sensitivity required for low-pressure gases. Measurements and calculations indicate that the important loss mechanisms are diffusion to the walls at low densities and collisional destruction of several types at plasma densities above 10 10 cm -3 . Production mechanisms must be highly efficient to compete with the losses. It appears to be straightforward to extrapolate measurements and theory to the densities above 10 12 cm -3 that are required for an intense source of D - for neutral beam injection into magnetically-confined fusion devices

  2. Production of a rapidly rotating plasma by cross-field injection of gun-produced plasma

    International Nuclear Information System (INIS)

    Ohzu, Akira; Ikehata, Takashi; Tanabe, Toshio; Mase, Hiroshi

    1984-01-01

    Cross-field plasma injection with use of a JxB plasma gun is described as a method to produce rapidly rotating plasma in a crossed electric and magnetic field system. The rotational velocity of the plasma is seriously limited by neutrals surrounding the plasma through strong interactions at the boundary layer. The concentration of neutrals can be reduced by the injection of fully or partially ionized plasma into the discharge volume instead of filling the volume with an operating gas. With use of this method, it is observed that the rotational velocity increases by a factor of 2 to 3 when compared with the conventional method of stationary gas-filling. (author)

  3. Investigation of the Periodic Absolute Parametric Instability in a Nonuniform Cylindrical Warm Plasma Waveguide

    International Nuclear Information System (INIS)

    Zaki, N.G.

    2009-01-01

    In this paper, the effect of spatial plasma nonuniformity on periodic Absolute Parametric Instability (API) of electrostatic waves in a magnetized pump warm plasma is investigated in a cylindrical geometry. An API plays a crucial role in the processes of the energy transfer from the electromagnetic radiation to the plasma and may have an important consequences for experiments on RF plasma heating in a magnetic traps and for a laser-fusion system. In conclusion; it is found that: A) allowance for the spatial nonuniformity of the plasma density leads to A.I) localization of an unstable wave in a finite region of a plasma volume, A.2) increasing the threshold value of the pump wave amplitude above which parametric amplification occurs and A.3) decreasing the value of the growth rate of unstable waves, B) more growth rate of periodic API is decreased due to electrons warmness in comparison with the case of cold plasma, and C) Independent of the geometry of the problem ( plane or cylinder), the results of the API in a warm plasma waveguide are still valid

  4. High-sodium intake prevents pregnancy-induced decrease of blood pressure in the rat.

    Science.gov (United States)

    Beauséjour, Annie; Auger, Karine; St-Louis, Jean; Brochu, Michéle

    2003-07-01

    Despite an increase of circulatory volume and of renin-angiotensin-aldosterone system (RAAS) activity, pregnancy is paradoxically accompanied by a decrease in blood pressure. We have reported that the decrease in blood pressure was maintained in pregnant rats despite overactivation of RAAS following reduction in sodium intake. The purpose of this study was to evaluate the impact of the opposite condition, e.g., decreased activation of RAAS during pregnancy in the rat. To do so, 0.9% or 1.8% NaCl in drinking water was given to nonpregnant and pregnant Sprague-Dawley rats for 7 days (last week of gestation). Increased sodium intakes (between 10- and 20-fold) produced reduction of plasma renin activity and aldosterone in both nonpregnant and pregnant rats. Systolic blood pressure was not affected in nonpregnant rats. However, in pregnant rats, 0.9% sodium supplement prevented the decreased blood pressure. Moreover, an increase of systolic blood pressure was obtained in pregnant rats receiving 1.8% NaCl. The 0.9% sodium supplement did not affect plasma and fetal parameters. However, 1.8% NaCl supplement has larger effects during gestation as shown by increased plasma sodium concentration, hematocrit level, negative water balance, proteinuria, and intrauterine growth restriction. With both sodium supplements, decreased AT1 mRNA levels in the kidney and in the placenta were observed. Our results showed that a high-sodium intake prevents the pregnancy-induced decrease of blood pressure in rats. Nonpregnant rats were able to maintain homeostasis but not the pregnant ones in response to sodium load. Furthermore, pregnant rats on a high-sodium intake (1.8% NaCl) showed some physiological responses that resemble manifestations observed in preeclampsia.

  5. Decreased plasma thiol antioxidant barrier and selenoproteins as potential biomarkers for ongoing methylmercury intoxication and an individual protective capacity.

    Science.gov (United States)

    Usuki, Fusako; Fujimura, Masatake

    2016-04-01

    Manifestation of methylmercury (MeHg) toxicity depends on individual susceptibility to MeHg, as well as MeHg burden level. Therefore, biomarkers that reflect the protective capacity against MeHg are needed. The critical role of oxidative stress in the pathogenesis of MeHg cytotoxicity has been demonstrated. Because MeHg has high affinity for selenohydryl groups, sulfhydryl groups, and selenides, and causes posttranscriptional defects in selenoenzymes, proteins with selenohydryl and sulfhydryl groups should play a critical role in mediating MeHg-induced oxidative stress. Here, plasma oxidative stress markers and selenoproteins were investigated in MeHg-intoxicated rats showing neuropathological changes after 4 weeks of MeHg exposure. The thiol antioxidant barrier (-SHp) level significantly decreased 2 weeks after MeHg exposure, which is an early stage at which no systemic oxidative stress, histopathological changes, or clinical signs were detected. Diacron reactive oxidant metabolite (d-ROM) levels significantly increased 3 weeks after MeHg exposure, indicating the occurrence of systemic oxidative stress. Rats treated with lead acetate or cadmium chloride showed no changes in levels of -SHp and d-ROM. Selenoprotein P1 abundance significantly decreased in MeHg-treated rats, whereas it significantly increased in rats treated with Pb or Cd. Plasma selenium-dependent glutathione peroxidase (GPx3) activity also significantly decreased after MeHg exposure, whereas plasma non-selenoenzyme glutathione reductase activity significantly increased in MeHg-treated rats. The results suggest that decreased capacity of -SHp and selenoproteins (GPx3 and selenoprotein P) can be useful biomarkers of ongoing MeHg cytotoxicity and the individual protective capacity against the MeHg body burden.

  6. Changes in Peak Oxygen Uptake and Plasma Volume in Fit and Unfit Subjects Following Exposure to a Simulation of Microgravity

    National Research Council Canada - National Science Library

    Convertino, Victor

    1997-01-01

    To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak...

  7. The effect of sintering conditions and ZrN volume fraction on the mechanical properties of spark plasma sintered W/ZrN composites

    International Nuclear Information System (INIS)

    Lee, Dongju; Umer, Malik Adeel; Shin, Yoochul; Jeon, Seokwoo; Hong, Soonhyung

    2012-01-01

    Highlights: ► Effect of sintering conditions on properties of W composites was investigated. ► Effect of ZrN volume fraction on properties of W composites was investigated. ► The grain size and relative density increased with increasing sintering temperature. ► ZrN particles led to an increase in strength of W and a decrease in grain size. ► Highest flexural strength was obtained for 10 vol.% W/ZrN with lowest agglomeration. - Abstract: In an effort to improve the room temperature mechanical properties of tungsten, W/ZrN composites were fabricated by high energy ball milling followed by spark plasma sintering at temperatures in a range of 1200–1700 °C under a pressure of 50 MPa. The effects of sintering conditions and ZrN volume fraction on the mechanical properties of the W/ZrN composites were studied and the results were compared to the properties of monolithic tungsten. The grain size of monolith tungsten and W/ZrN composites was found to increase with an increase in sintering temperature and time. In the case of the W/ZrN composites, ZrN particles led to an increase in the compressive strength of tungsten and a decrease in grain size. The increase in compressive strength of the composites was attributed to a reinforcement effect of ZrN particles as well as grain size refinement according to the Hall–Petch relation. Compressive strength of the composites increased with increasing ZrN content while the flexural strength decreased for samples with ZrN content exceeding 10 vol.%. This was attributed to the effects of ZrN agglomeration within the tungsten matrix.

  8. Decreased plasma levels of the endothelial protective sphingosine-1-phosphate are associated with dengue-induced plasma leakage

    NARCIS (Netherlands)

    Michels, M.; Japtok, L.; Alisjahbana, B.; Wisaksana, R.; Sumardi, U.; Puspita, M.; Kleuser, B.; Mast, Q. de; Ven, A.J.A.M. van der

    2015-01-01

    BACKGROUND: A transient endothelial hyperpermeability is a hallmark of severe dengue infections. Sphingosine-1-phosphate (S1P) maintains vascular integrity and protects against plasma leakage. We related plasma S1P levels to dengue-induced plasma leakage and studied mechanisms that may underlie the

  9. Low and intermediate level radioactive waste processing in plasma reactor

    International Nuclear Information System (INIS)

    Sauchyn, V.; Khvedchyn, I.; Van Oost, G.

    2013-01-01

    Methods of low and intermediate level radioactive waste processing comprise: cementation, bituminization, curing in polymer matrices, combustion and pyrolysis. All these methods are limited in their application in the field of chemical, morphological, and aggregate composition of material to be processed. The thermal plasma method is one of the universal methods of RAW processing. The use of electric-arc plasma with mean temperatures 2000 - 8000 K can effectively carry out the destruction of organic compounds into atoms and ions with very high speeds and high degree of conversion. Destruction of complex substances without oxygen leads to a decrease of the volume of exhaust gases and dimension of gas cleaning system. This paper presents the plasma reactor for thermal processing of low and intermediate level radioactive waste of mixed morphology. The equipment realizes plasma-pyrolytic conversion of wastes and results in a conditioned product in a single stage. As a result, the volume of conditioned waste is significantly reduced (more than 10 times). Waste is converted into an environmentally friendly form that suits long-term storage. The leaching rate of macro-components from the vitrified compound is less than 1.10 -7 g/(cm 2 .day). (authors)

  10. Simvastatin decreases steroid production in the H295R cell line and decreases steroids and FSH in female rats

    DEFF Research Database (Denmark)

    Jensen, Anna Guldvang; Hansen, Cecilie Hurup; Weisser, Johan J

    2015-01-01

    .10-0.13μM for SV and from 0.019-0.055μM for SVA. In rats, SV decreased progestagens in ovaries, brain and plasma, and plasma FSH in the M (72.4% decrease) and H group (76.6% decrease). Because progestagens and gonadotropins are major players in fertility, administration of SV might exert negative effects...

  11. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects. Final science report

    International Nuclear Information System (INIS)

    Pickett, J.S.; Frank, L.A.; Kurth, W.S.

    1988-06-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B

  12. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  13. Colloid volume loading does not mitigate decreases in central blood volume during simulated hemorrhage while heat stressed

    DEFF Research Database (Denmark)

    Crandall, Craig G; Wilson, Thad E; Marving, Jens

    2012-01-01

    attenuates the reduction in regional blood volumes during a simulated hemorrhagic challenge imposed via lower-body negative pressure (LBNP). Seven subjects underwent 30 mmHg LBNP while normothermic, during passive heat stress (increased internal temperature ~1°C), and while continuing to be heated after...... intravenous colloid volume loading (11 ml/kg). Relative changes in torso and regional blood volumes were determined by gamma camera imaging with technetium-99m labeled erythrocytes. Heat stress reduced blood volume in all regions (ranging from 7 to 16%), while subsequent volume loading returned those values...... to normothermic levels. While normothermic, LBNP reduced blood volume in all regions (torso: 22±8%; heart: 18±6%; spleen: 15±8%). During LBNP while heat stressed, the reductions in blood volume in each region were markedly greater when compared to LBNP while normothermic (torso: 73±2%; heart: 72±3%; spleen: 72...

  14. Atmospheric Gaseous Plasma with Large Dimensions

    Science.gov (United States)

    Korenev, Sergey

    2012-10-01

    The forming of atmospheric plasma with large dimensions using electrical discharge typically uses the Dielectric Barrier Discharge (DBD). The study of atmospheric DBD was shown some problems related to homogeneous volume plasma. The volume of this plasma determines by cross section and gas gap between electrode and dielectric. The using of electron beam for volume ionization of air molecules by CW relativistic electron beams was shown the high efficiency of this process [1, 2]. The main advantage of this approach consists in the ionization of gas molecules by electrons in longitudinal direction determines by their kinetic energy. A novel method for forming of atmospheric homogeneous plasma with large volume dimensions using ionization of gas molecules by pulsed non-relativistic electron beams is presented in the paper. The results of computer modeling for delivered doses of electron beams in gases and ionization are discussed. The structure of experimental bench with plasma diagnostics is considered. The preliminary results of forming atmospheric plasma with ionization gas molecules by pulsed nanosecond non-relativistic electron beam are given. The analysis of potential applications for atmospheric volume plasma is presented. Reference: [1] S. Korenev. ``The ionization of air by scanning relativistic high power CW electron beam,'' 2002 IEEE International Conference on Plasma Science. May 2002, Alberta, Canada. [2] S. Korenev, I. Korenev. ``The propagation of high power CW scanning electron beam in air.'' BEAMS 2002: 14th International Conference on High-Power Particle Beams, Albuquerque, New Mexico (USA), June 2002, AIP Conference Proceedings Vol. 650(1), pp. 373-376. December 17.

  15. Influence of plasma molybdenizing and shot-peening on fretting damage behavior of titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chang-bin, E-mail: tcbtop@126.com [School of Metallurgy and Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055 (China); Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Liu, Dao-xin, E-mail: liudaox@nwpu.edu.cn [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Tang, Bin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Zhang, Xiao-hua [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Qin, Lin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Liu, Cheng-song [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China)

    2016-12-30

    Highlights: • Plasma molybdenizing increases FW resistance of Ti6Al4V, but reduces its FF life. • Shot-peened plasmamolybdenizing surface enhances FW and FF resistance of Ti6Al4V. • Combined treatment yields low surface-roughness & high hardness gradient distribution. • Combined treatment yields beneficial residual compressive stress & good toughness. • Anti-wear & -fatigue performance improvements for surface engineering applications. - Abstract: Effect of plasma molybdenizing and shot-peening on fretting wear and fretting fatigue behaviors of Ti6Al4V alloy was investigated. The plasma molybdenized layer composed of a dense molybdenum deposition layer and a Mo–Ti solid–solution layer can increase surface hardness by 2.8 times and cause its volume loss by fretting wear to decrease to 1/14 compared with that of the substrate. Plasma molybdenized treatment results in a significant decrease in resistance of the substrate to fretting fatigue. It is ascribed that the molybdenized layer with high hardness yields a low toughness, and its high surface roughness leads to a micro-notched effect. However, proper combination plasma molybdenizing and subsequent shot-peening may enhance the simultaneous fretting fatigue and fretting wear resistance of Ti6Al4V significantly, which can decrease the fretting wear volume loss to 1/27, and may increase the fretting fatigue life by more than 69 times. A synergistic improvement in fretting fatigue of the titanium alloy by combining surface alloying with shot-peening can be achieved. The results indicate that a beneficial residual compressive stress distribution, high surface hardness with suitable hardness gradient distribution, good apparent toughness, relatively low surface roughness, and excellent surface integrity are achieved.

  16. Plasma pro-atrial natriuretic peptide to estimate fluid balance during open and robot-assisted esophagectomy

    DEFF Research Database (Denmark)

    Strandby, Rune Broni; Ambrus, Rikard; Secher, Niels H

    2017-01-01

    BACKGROUND: It remains debated how much fluid should be administered during surgery. The atrial natriuretic peptide precursor proANP is released by atrial distension and deviations in plasma proANP are reported associated with perioperative fluid balance. We hypothesized that plasma proANP would...... decrease when the central blood volume is compromised during the abdominal part of robot-assisted hybrid (RE) esophagectomy and that a positive fluid balance would be required to maintain plasma proANP. METHODS: Patients undergoing RE (n = 25) or open (OE; n = 25) esophagectomy for gastroesophageal cancer...

  17. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, P. K., E-mail: pkumar@ipr.res.in; Singh, S. K.; Sanyasi, A. K.; Awasthi, L. M., E-mail: kushagra.lalit@gmail.com; Mattoo, S. K. [Institute for Plasma Research, Gandhinagar (India)

    2016-07-15

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  18. Pulmonary Edema and Plasma Volume Changes in Dysbarism. M.S. Thesis - Texas Univ.

    Science.gov (United States)

    Joki, J. A.

    1972-01-01

    Two groups of anesthetized, fasted pigs were utilized. One group of 13 animals (8.5 to 16.6 kilograms) was exposed to a high-pressure environment, and the other group of eight animals (6.9 to 20.0 kilograms) constituted the control group. The experimental group was subjected to an atmosphere of 90 percent nitrogen and 10 percent oxygen at a pressure of 50 psig for 30 minutes and then decompressed at a rate 10 psi/min. Plasma volumes, using both iodine-125-tagged-albumin and chromium-51-tagged-cell dilution techniques, were measured before, immediately after, and at 30 and 60 minutes after decompression. Aortic and right-ventricular systolic pressures were also recorded. At 60 minutes after decompression, blood samples were taken, the animals were sacrificed, and the water content of the lungs, kidneys, livers, and spleens was estimated by measuring tissue wet weight and dry weight. Protein extravasation and tissue blood volumes were determined by measuring the iodine-125-tagged-albumin and chromium-51-tagged-cell spaces in homo-genates of the organs under investigation.

  19. Effects of Hypertonic Saline Solution on Clinical Parameters, Serum Electrolytes and Plasma Volume in the Treatment of Haemorrhagic Septicaemia in Buffaloes

    Directory of Open Access Journals (Sweden)

    M. Arif Zafar*, G. Muhammad, Zafar Iqbal1 and M. Riaz2

    2010-04-01

    Full Text Available This study was conducted to determine the efficacy of hypertonic saline solution (HSS along with antibiotic (ceftiofur HCl and non-steroidal anti-inflammatory drug (ketoprofen in the treatment of haemorrhagic septicaemia in buffaloes. For this purpose, 50 buffaloes suffering from haemorrhagic septicaemia were randomly divided in two equal groups A and B. Group A served as control and was treated with ceftiofur HCl (IM and ketoprofen (IV @ 6 and 2 mg/Kg BW, respectively, for five days. Buffaloes of group B were administered with rapid intravenous infusion of hypertonic saline solution (7.5% NaCl @ 4 ml/Kg BW once in combination with ceftiofur HCl and ketoprofen. Animals were monitored for 24 hours after initiation of treatment. Clinical parameters, serum electrolytes, plasma volume and survival index were recorded at different intervals after treatment. Survival rate (80% in group B was significantly higher (P<0.05 than 48% in group A. The heart rate and respiration rate recovered more effectively in the buffaloes administered with treatment protocol B. Plasma volume was 98% which was almost normal within 24 hours after the infusion of hypertonic saline solution to the animals of group B. It was concluded from the study that hypertonic saline solution as an adjunct to antibiotic and a non-steroidal anti-inflammatory drug more efficiently improved respiration and heart rates and effectively restored plasma volume in resuscitating the buffaloes from haemorrhagic septicaemia than the conventional treatment.

  20. Atmospheric pressure plasma processing of polymeric materials utilizing close proximity indirect exposure

    Science.gov (United States)

    Paulauskas, Felix L.; Bonds, Truman

    2016-09-20

    A plasma treatment method that includes providing treatment chamber including an intermediate heating volume and an interior treatment volume. The interior treatment volume contains an electrode assembly for generating a plasma and the intermediate heating volume heats the interior treatment volume. A work piece is traversed through the treatment chamber. A process gas is introduced to the interior treatment volume of the treatment chamber. A plasma is formed with the electrode assembly from the process gas, wherein a reactive species of the plasma is accelerated towards the fiber tow by flow vortices produced in the interior treatment volume by the electrode assembly.

  1. Characterization of the island divertor plasma of W7-AS stellarator in the deeply detached state with volume recombination

    International Nuclear Information System (INIS)

    Ramasubramanian, N.; Koenig, R.; Feng, Y.; Giannone, L.; Grigull, P.; Klinger, T.; McCormick, K.; Thomsen, H.; Wenzel, U.

    2004-01-01

    In the high-density H-mode of the Stellarator Wendelstein 7-AS, the plasma detaches from the island divertor targets when the line-averaged density exceeds a critical value. This quasi-stationary detachment is found to be partial and shows edge-localized, poloidally asymmetric radiation. The spectroscopic characteristics of the deeply detached plasma are reported, including evidence for volume recombination. The detached plasma radiates up to 90% of the absorbed power with larger contributions from the locations close to magnetic X-points outside the divertor region. The spectral analysis of the Balmer series indicate very high densities and low temperatures at the detached regions. The results of the spectral analysis underline the importance of three-dimensional modelling. An initial comparison is made with the latest results from EMC3-EIRENE modelling. (author)

  2. Effects of plasma viscosity modulation on cardiac function during moderate hemodilution

    Directory of Open Access Journals (Sweden)

    Chatpun Surapong

    2010-01-01

    Full Text Available Background : Previous studies have found that increasing plasma viscosity as whole blood viscosity decrease has beneficial effects in microvascular hemodynamics. As the heart couples with systemic vascular network, changes in plasma and blood viscosity during hemodilution determine vascular pressure drop and flow rate, which influence cardiac function. This study aimed to investigate how changes in plasma viscosity affect on cardiac function during acute isovolemic hemodilution. Materials and Methods: Plasma viscosity was modulated by hemodilution of 40% of blood volume with three different plasma expanders (PEs. Dextran 2000 kDa (Dx2M, 6.3 cP and dextran 70 kDa (Dx70, 3.0 cP were used as high and moderate viscogenic PEs, respectively. Polyethylene glycol conjugated with human serum albumin (PEG-HSA, 2.2 cP was used as low viscogenic PE. The cardiac function was assessed using a miniaturized pressure-volume conductance catheter. Results: After hemodilution, pressure dropped to 84%, 79%, and 78% of baseline for Dx2M, Dx70 and PEG-HSA, respectively. Cardiac output markedly increased for Dx2M and PEG-HSA. Dx2M significantly produced higher stroke work relative to baseline and compared to Dx70. Conclusion: Acute hemodilution with PEG-HSA without increasing plasma viscosity provided beneficial effects on cardiac function compared to Dx70, and similar to those measured with Dx2M. Potentially negative effects of increasing peripheral vascular resistance due to the increase in plasma viscosity were prevented.

  3. IPOMOEA BATATAS SYRUP DECREASE MALONDIALDEHYDE AND INCREASE NITROUS OXIDE PLASMA LEVELS AMONGST MODERATE SMOKER WORKERS AT DENPASAR

    Directory of Open Access Journals (Sweden)

    I Dewa Ayu Intan Dwi-Primayanti

    2012-09-01

    Full Text Available Objective: Cells and tissues are continuously damaged by reactive oxygen species. Cigarette smoke is one of an exogenous source of free radical containing more than 4000 chemical compounds, that triggering the formation of free radicals related to diseases and aging process. Anthocyanins are potent antioxidants that are widely distributed in fruit, vegetables, red wines and Ipomea batatas. The aim of this study was to determine the effect of Ipomea batatas as a source of antioxidants in decreasing levels of alondialdehyde (MDA and increasing of Nitrous oxide (nitrite/nitrate/NOxplasma in moderate smokers of workers at Denpasar.Method: This was an experimental study with a pretest-posttest control groups design. There are 33 moderate smokers who were divided into three groups, control group (placebo, treatment group with 15 ml purple sweet potato syrup (P1 and 30 ml (P2, for 14 days. All groups were performed the laboratory examinations for MDA and NOx plasma before and after the treatment.Results: This study showed that there were significant differences (p<0.05 both in MDA and NOx plasma levels in the control group, P1 and P2. The decrease of MDAlevels on P1 was 35.39% and on P2 was 49.87%. The increase of NOx plasma levels was 7.78% for P1 and 14.68% for P2.Conclusion: From this study, it can be concluded that Ipomea batatas syrup contains of 8mg/mL anthocyanins, probably play a role in reducing the free radical and thus reducingthe risk of disease and slowing the aging process.

  4. Decreased Fibroblast and Increased Osteoblast Functions on Ionic Plasma Deposited Nanostructured Ti Coatings

    Directory of Open Access Journals (Sweden)

    Storey Dan

    2007-01-01

    Full Text Available AbstractBioactive coatings are in high demand to control cellular functions for numerous medical devices. The objective of this in vitro study was to characterize for the first time fibroblast (fibrous scar tissue forming cells adhesion and proliferation on an important polymeric biomaterial (silicone coated with titanium using a novel ionic plasma deposition (IPD process. Fibroblasts are one of the first anchorage-dependent cells to arrive at an implant surface during the wound healing process. Persistent excessive functions of fibroblasts have been linked to detrimental fibrous tissue formation which may cause implant failure. The IPD process creates a surface-engineered nanostructure (with features usually below 100 nm by first using a vacuum to remove all contaminants, then guiding charged metallic ions or plasma to the surface of a medical device at ambient temperature. Results demonstrated that compared to currently used titanium and uncoated silicone, silicone coated with titanium using IPD significantly decreased fibroblast adhesion and proliferation. Results also showed competitively increased osteoblast (bone-forming cells over fibroblast adhesion on silicone coated with titanium; in contrast, osteoblast adhesion was not competitively increased over fibroblast adhesion on uncoated silicone or titanium controls. In this manner, this study strongly suggests that IPD should be further studied for biomaterial applications in which fibrous tissue encapsulation is undesirable (such as for orthopedic implants, cardiovascular components, etc..

  5. Modelling of an intermediate pressure microwave oxygen discharge reactor: from stationary two-dimensional to time-dependent global (volume-averaged) plasma models

    International Nuclear Information System (INIS)

    Kemaneci, Efe; Graef, Wouter; Rahimi, Sara; Van Dijk, Jan; Kroesen, Gerrit; Carbone, Emile; Jimenez-Diaz, Manuel

    2015-01-01

    A microwave-induced oxygen plasma is simulated using both stationary and time-resolved modelling strategies. The stationary model is spatially resolved and it is self-consistently coupled to the microwaves (Jimenez-Diaz et al 2012 J. Phys. D: Appl. Phys. 45 335204), whereas the time-resolved description is based on a global (volume-averaged) model (Kemaneci et al 2014 Plasma Sources Sci. Technol. 23 045002). We observe agreement of the global model data with several published measurements of microwave-induced oxygen plasmas in both continuous and modulated power inputs. Properties of the microwave plasma reactor are investigated and corresponding simulation data based on two distinct models shows agreement on the common parameters. The role of the square wave modulated power input is also investigated within the time-resolved description. (paper)

  6. Low density lipoprotein for oxidation and metabolic studies. Isolation from small volumes of plasma using a tabletop ultracentrifuge.

    Science.gov (United States)

    Himber, J; Bühler, E; Moll, D; Moser, U K

    1995-01-01

    A rapid method is described for the isolation of small volumes of plasma low density lipoprotein (LDL) free of plasma protein contaminants using the TL-100 Tabletop Ultracentrifuge (Beckman). The isolation of LDL was achieved by a 25 min discontinuous gradient density centrifugation between the density range of 1.006 and 1.21 g/ml, recovery of LDL by tube slicing followed by a 90 min flotation step (d = 1.12 g/ml). The purity of LDL and apolipoprotein B100 (apo B100) were monitored by agarose electrophoresis, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), radial immunodiffusion and micropreparative fast protein liquid chromatography (FPLC). The ability of LDL oxidation was assessed by following absorbance at 234 nm after addition of copper ions. The functional integrity of the isolated LDL was checked by clearance kinetics after injection of [125I]-labelled LDL in estrogen-treated rats. The additional purification step led to LDL fractions free of protein contamination and left apo B100, alpha-tocopherol and beta-carotene intact. The LDL prepared in this way was free of albumin, as evident from analytic tests and from its enhanced oxidative modification by copper ions. Used for analytical purposes, this method allows LDL preparations from plasma volumes up to 570 microliters. This method is also convenient for metabolic studies in small animals, especially those relating to the determination of kinetic parameters of LDL in which LDL-apo B100 has to be specifically radiolabelled.

  7. Plasma biomarkers of decreased vesicular storage distinguish Parkinson disease with orthostatic hypotension from the parkinsonian form of multiple system atrophy.

    Science.gov (United States)

    Goldstein, David S; Kopin, Irwin J; Sharabi, Yehonatan; Holmes, Courtney

    2015-02-01

    Parkinson disease with orthostatic hypotension (PD + OH) and the parkinsonian form of multiple system atrophy (MSA-P) can be difficult to distinguish clinically. Recent studies indicate that PD entails a vesicular storage defect in catecholaminergic neurons. Although cardiac sympathetic neuroimaging by (18)F-dopamine positron emission tomography can identify decreased vesicular storage, this testing is not generally available. We assessed whether plasma biomarkers of a vesicular storage defect can separate PD + OH from MSA-P. We conceptualized that after F-dopamine injection, augmented production of F-dihydroxyphenylacetic acid (F-DOPAC) indicates decreased vesicular storage, and we therefore predicted that arterial plasma F-DOPAC would be elevated in PD + OH but not in MSA-P. We measured arterial plasma F-DOPAC after (18)F-dopamine administration (infused i.v. over 3 min) in patients with PD + OH (N = 12) or MSA-P (N = 21) and in healthy control subjects (N = 26). Peak F-DOPAC:dihydroxyphenylglycol (DHPG) was also calculated to adjust for effects of denervation on F-DOPAC production. Plasma F-DOPAC accumulated rapidly after initiation of (18)F-dopamine infusion. Peak F-DOPAC (5-10 min) in PD + OH averaged three times that in MSA-P (P 300 nCi-kg/cc-mCi, in contrast with 7 of 12 PD + OH patients (χ(2) = 16.6, P < 0.0001). DHPG was lower in PD + OH (3.83 ± 0.36 nmol/L) than in MSA-P (5.20 ± 0.29 nmol/L, P = 0.007). All MSA-P patients had peak F-DOPAC:DHPG < 60, in contrast with 9 of 12 PD + OH patients (χ(2) = 17.5, P < 0.0001). Adjustment of peak F-DOPAC for DHPG increased test sensitivity from 58 to 81% at similar high specificity. After F-dopamine injection, plasma F-DOPAC and F-DOPAC:DHPG distinguish PD + OH from MSA-P.

  8. Decreased insulin clearance in individuals with elevated 1-h post-load plasma glucose levels.

    Directory of Open Access Journals (Sweden)

    Maria Adelaide Marini

    Full Text Available Reduced insulin clearance has been shown to predict the development of type 2 diabetes. Recently, it has been suggested that plasma glucose concentrations ≥ 8.6 mmol/l (155 mg/dl at 1 h during an oral glucose tolerance test (OGTT can identify individuals at high risk for type 2 diabetes among those who have normal glucose tolerance (NGT 1 h-high. The aim of this study was to examine whether NGT 1 h-high have a decrease in insulin clearance, as compared with NGT individuals with 1-h post-load glucose <8.6 mmol/l (l (155 mg/dl, NGT 1 h-low. To this end, 438 non-diabetic White individuals were subjected to OGTT and euglycemic-hyperinsulinemic clamp to evaluate insulin clearance and insulin sensitivity. As compared with NGT 1 h-low individuals, NGT 1 h-high had significantly higher 1-h and 2-h post-load plasma glucose and 2-h insulin levels as well as higher fasting glucose and insulin levels. NGT 1 h-high exhibited also a significant decrease in both insulin sensitivity (P<0.0001 and insulin clearance (P = 0.006 after adjusting for age, gender, adiposity measures, and insulin sensitivity. The differences in insulin clearance remained significant after adjustment for fasting glucose (P = 0.02 in addition to gender, age, and BMI. In univariate analyses adjusted for gender and age, insulin clearance was inversely correlated with body weight, body mass index, waist, fat mass, 1-h and 2-h post-load glucose levels, fasting, 1-h and 2-h post-load insulin levels, and insulin-stimulated glucose disposal. In conclusion, our data show that NGT 1 h-high have a reduction in insulin clearance as compared with NGT 1 h-low individuals; this suggests that impaired insulin clearance may contribute to sustained fasting and post-meal hyperinsulinemia.

  9. Fibrinogen Reduction During Selective Plasma Exchange due to Membrane Fouling.

    Science.gov (United States)

    Ohkubo, Atsushi; Okado, Tomokazu; Miyamoto, Satoko; Hashimoto, Yurie; Komori, Shigeto; Yamamoto, Motoki; Maeda, Takuma; Itagaki, Ayako; Yamamoto, Hiroko; Seshima, Hiroshi; Kurashima, Naoki; Iimori, Soichiro; Naito, Shotaro; Sohara, Eisei; Uchida, Shinichi; Rai, Tatemitsu

    2017-06-01

    Fibrinogen is substantially reduced by most plasmapheresis modalities but retained in selective plasma exchange using Evacure EC-4A10 (EC-4A). Although EC-4A's fibrinogen sieving coefficient is 0, a session of selective plasma exchange reduced fibrinogen by approximately 19%. Here, we investigated sieving coefficient in five patients. When the mean processed plasma volume was 1.15 × plasma volume, the mean reduction of fibrinogen during selective plasma exchange was approximately 15%. Fibrinogen sieving coefficient was 0 when the processed plasma volume was 1.0 L, increasing to 0.07 when the processed plasma volume was 3.0 L, with a mean of 0.03 during selective plasma exchange. When fibrinogen sieving coefficient was 0, selective plasma exchange reduced fibrinogen by approximately 10%. Scanning electron microscopy images revealed internal fouling of EC-4A's hollow fiber membrane by substances such as fibrinogen fibrils. Thus, fibrinogen reduction by selective plasma exchange may be predominantly caused by membrane fouling rather than filtration. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  10. Plasma physics

    CERN Document Server

    Drummond, James E

    1961-01-01

    A historic snapshot of the field of plasma physics, this fifty-year-old volume offers an edited collection of papers by pioneering experts in the field. In addition to assisting students in their understanding of the foundations of classical plasma physics, it provides a source of historic context for modern physicists. Highly successful upon its initial publication, this book was the standard text on plasma physics throughout the 1960s and 70s.Hailed by Science magazine as a ""well executed venture,"" the three-part treatment ranges from basic plasma theory to magnetohydrodynamics and microwa

  11. Resistance exercise-induced fluid shifts: change in active muscle size and plasma volume

    Science.gov (United States)

    Ploutz-Snyder, L. L.; Convertino, V. A.; Dudley, G. A.

    1995-01-01

    The purpose of this study was to test the hypothesis that the reduction in plasma volume (PV) induced by resistance exercise reflects fluid loss to the extravascular space and subsequently selective increase in cross-sectional area (CSA) of active but not inactive skeletal muscle. We compared changes in active and inactive muscle CSA and PV after barbell squat exercise. Magnetic resonance imaging (MRI) was used to quantify muscle involvement in exercise and to determine CSA of muscle groups or individual muscles [vasti (VS), adductor (Add), hamstring (Ham), and rectus femoris (RF)]. Muscle involvement in exercise was determined using exercise-induced contrast shift in spin-spin relaxation time (T2)-weighted MR images immediately postexercise. Alterations in muscle size were based on the mean CSA of individual slices. Hematocrit, hemoglobin, and Evans blue dye were used to estimate changes in PV. Muscle CSA and PV data were obtained preexercise and immediately postexercise and 15 and 45 min thereafter. A hierarchy of muscle involvement in exercise was found such that VS > Add > Ham > RF, with the Ham and RF showing essentially no involvement. CSA of the VS and Add muscle groups were increased 10 and 5%, respectively, immediately after exercise in each thigh with no changes in Ham and RF CSA. PV was decreased 22% immediately following exercise. The absolute loss of PV was correlated (r2 = 0.75) with absolute increase in muscle CSA immediately postexercise, supporting the notion that increased muscle size after resistance exercise reflects primarily fluid movement from the vascular space into active but not inactive muscle.

  12. Plasma-sprayed tantalum/alumina cermets

    International Nuclear Information System (INIS)

    Kramer, C.M.

    1977-12-01

    Cermets of tantalum and alumina were fabricated by plasma spraying, with the amount of alumina varied from 0 to 65 percent (by volume). Each of four compositions was then measured for tensile strength, elastic modulus, and coefficient of thermal expansion. In general, strength and strain to failure decreased with increasing alumina content: 62 MPa for 100 percent Ta to 19 MPa for 35 v percent Ta. A maximum of 0.1 percent strain was observed for the sprayed 100 percent Ta specimens. The coefficient of thermal expansion measured for the pure Ta was 6.2 (10 -6 )/K

  13. Formation of tissue factor activity following incubation of recombinant human tissue factor apoprotein with plasma lipoproteins

    International Nuclear Information System (INIS)

    Sakai, T.; Kisiel, W.

    1990-01-01

    Incubation of recombinant human tissue factor apoprotein (Apo-TF) with human plasma decreased the recalcified clotting time of this plasma in a time-and dose-dependent manner suggesting relipidation of the Apo-TF by plasma lipoproteins. Incubation of Apo-TF with purified preparations of human very low density, low density and high density lipoproteins resulted in tissue factor activity in a clotting assay. The order of effectiveness was VLDL greater than LDL much greater than HDL. Tissue factor activity generated by incubation of a fixed amount of Apo-TF with plasma lipoproteins was lipoprotein concentration-dependent and saturable. The association of Apo-TF with lipoprotein particles was supported by gel filtration studies in which 125 I-Apo-TF coeluted with the plasma lipoprotein in the void volume of a Superose 6 column in the presence and absence of calcium ions. In addition, void-volume Apo-TF-lipoprotein fractions exhibited tissue factor activity. These results suggest that the factor VIII-bypassing activity of bovine Apo-TF observed in a canine hemophilic model may be due, in part, to its association with plasma lipoproteins and expression of functional tissue factor activity

  14. Power absorption and confinement studies of ICRF-heated plasma in JIPP T-IIU tokamak

    International Nuclear Information System (INIS)

    Ida, K.; Ogawa, Y.; Toi, K.

    1988-08-01

    The energy confinement characteristics of ICRF-heated tokamak plasmas are studied at high input power density ∼ 2 MWm -3 volume averaged, on the JIPP T-IIU device(R = 0.91 m/a = 0.23 m). High electron and ion temperatures (T e ∼ 2.5 keV, T i ∼ 2.0 keV, at each maximum) have been achieved by the operation at a plasma current I P of 280 kA, plasma line-averaged electron density n-bar e of 7 x 10 13 cm -3 and input power of 2 MW, with a suppression of total radiation loss (30 to 40 % of the total input power) by a carbon coating on the vacuum vessel. The fraction of ICRF power absorbed by the plasma, α, is determined experimentally from the decay of the stored plasma energy just after the ICRF pulse is terminated. The value of α increases slightly with increasing electron density and decreases from 90 to 70 % as the ICRF power is increased from 1 MWm -3 to 2 MWm -3 volume averaged. The global energy confinement time τ E , defined by W P /(P OH + αP rf ), decreases by a factor of 2 ∼ 3 from that in ohmic plasmas as the heating power increases up to 2 MW. It is found that the energy confinement time has a strong line-averaged electron density dependence as τ E ∝n-bar e 0.6 , which is obtained by the use of the measured absorbed power, while the Kaye-Goldston scaling predicts τ E ∝n-bar e 0.26 . (author)

  15. Anorexia Nervosa during Adolescence Is Associated with Decreased Gray Matter Volume in the Inferior Frontal Gyrus.

    Directory of Open Access Journals (Sweden)

    Takashi X Fujisawa

    Full Text Available Anorexia nervosa (AN is an eating disorder characterized by the relentless pursuit to lose weight, mostly through self-starvation, and a distorted body image. AN tends to begin during adolescence among women. However, the underlying neural mechanisms related to AN remain unclear. Using voxel-based morphometry based on magnetic resonance imaging scans, we investigated whether the presence of AN was associated with discernible changes in brain morphology. Participants were 20 un-medicated, right-handed patients with early-onset AN and 14 healthy control subjects. Group differences in gray matter volume (GMV were assessed using high-resolution, T1-weighted, volumetric magnetic resonance imaging datasets (3T Trio scanner; Siemens AG and analyzed after controlling for age and total GMV, which was decreased in the bilateral inferior frontal gyrus (IFG (left IFG: FWE corrected, p < 0.05; right IFG: uncorrected, p < 0.05 of patients with AN. The GMV in the bilateral IFG correlated significantly with current age (left IFG: r = -.481, p < .05; right IFG: r = -.601, p < .01 and was limited to the AN group. We speculate that decreased IFG volume might lead to deficits in executive functioning or inhibitory control within neural reward systems. Precocious or unbalanced neurological trimming within this particular region might be an important factor for the pathogenesis of AN onset.

  16. Decreased gray matter volume of the medial orbitofrontal cortex in panic disorder with agoraphobia: a preliminary study.

    Science.gov (United States)

    Na, Kyoung-Sae; Ham, Byung-Joo; Lee, Min-Soo; Kim, Leen; Kim, Yong-Ku; Lee, Heon-Jeong; Yoon, Ho-Kyoung

    2013-08-01

    Patients with panic disorder with agoraphobia (PDA) have clinical symptoms such as the fear of being outside or of open spaces from which escape would be difficult. Although recent neurobiological studies have suggested that fear conditioning and extinction are associated with PDA, no study has examined the possible structural abnormalities in patients with PDA. This preliminary study compares the gray matter volume among patients with PDA, those with panic disorder without agoraphobia (PDW), and healthy controls (HC) using high-resolution 3.0 T magnetic resonance imaging (MRI) with voxel-based morphometry (VBM). Compared with HC, patients with PDA showed decreased gray matter volume in their left medial orbitofrontal gyrus. However, differences were not found in the gray matter volumes of patients with PDW and whole panic disorder compared with HC. These findings suggest that the phobic avoidance found in patients with PDA arise from abnormalities in the medial orbitofrontal cortex, which plays an important role in fear extinction. Future studies should investigate the neuroanatomical substrates of PDA and distinguish them from those of PDW. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. The impact of maternal plasma volume expansion and antihypertensive treatment with intravenous dihydralazine on fetal and maternal hemodynamics during pre-eclampsia: a clinical, echo-Doppler and viscometric study.

    NARCIS (Netherlands)

    Boito, S.M.; Struijk, P.C.; Pop, G.A.M.; Visser, W. de; Steegers, E.A.P.; Wladimiroff, J.W.

    2004-01-01

    OBJECTIVES: To establish the effects of plasma volume expansion (PVE) followed by intravenous dihydralazine (DH) administration on maternal whole blood viscosity (WBV) and hematocrit, uteroplacental and fetoplacental downstream impedance and umbilical venous (UV) volume flow in pre-eclampsia.

  18. Coblation technology: plasma-mediated ablation for otolaryngology applications

    Science.gov (United States)

    Woloszko, Jean; Gilbride, Charles

    2000-05-01

    Coblation is a unique method of delivering radio frequency energy to soft tissue for applications in Otolaryngology (ENT). Using radio frequency in a bipolar mode with a conductive solution, such as saline, Coblation energizes the ions in the saline to form a small plasma field. The plasma has enough energy to break the tissue's molecular bonds, creating an ablative path. The thermal effect of this process is approximately 45 - 85 degrees Celsius, significantly lower than traditional radio-frequency techniques. Coblation has been used for Otolaryngological applications such as Uvulopalatopharyngoplasty (UPPP), tonsillectomy, turbinate reduction, palate reduction, base of tongue reduction and various Head and Neck cancer procedures. The decreased thermal effect of Coblation anecdotally has led to less pain and faster recovery for cases where tissue is excised. In cases where Coblation is applied submucosally to reduce tissue volume (inferior turbinate, soft palate), the immediate volume reduction may lead to immediate clinical benefits for the patient. Coblation is currently being tested in various clinical studies to document the benefits for otolaryngological applications.

  19. Oligonol supplementation modulates plasma volume and osmolality and sweating after heat load in humans.

    Science.gov (United States)

    Lee, JeongBeom; Shin, YoungOh; Murota, Hiroyuki

    2015-05-01

    Oligonol is a low-molecular-weight polyphenol that possesses antioxidant and anti-inflammatory properties. This study investigated the effects of Oligonol supplementation on sweating response, plasma volume (PV), and osmolality (Osm) after heat load in human volunteers. We conducted a placebo-controlled crossover trial. Participants took a daily dose of 200 mg Oligonol or placebo for 1 week. After a 2-week washout period, the subjects were switched to the other study arm. As a heat load, half-body immersion into hot water (42°C±0.5°C for 30 min) was performed in an automated climate chamber. Tympanic and mean body temperature (Tty, mTb) and whole-body sweat loss volume (WBSLV) were measured. Changes in PV, Osm, and serum levels of aldosterone and sodium were analyzed. Oligonol intake attenuated increases in Tty, mTb, and WBSLV after heat load compared with the placebo (Pbody temperature and excessive sweating under heat load in healthy humans, but interpretation of the results requires caution due to the potent diuretic effect of Oligonol.

  20. State of art data acquisition system for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, Ritesh; Srivastava, Pankaj; Sanyasi, Amulya Kumar; Srivastav, Prabhakar; Awasthi, Lalit Mohan; Mattoo, Shiban Krishna; Parmar, Vijay; Makadia, Keyur; Patel, Ishan; Shah, Sandeep

    2015-01-01

    The Large volume plasma device (LVPD) is a cylindrical device (ϕ = 2m, L = 3m) dedicated for carrying out investigations on plasma physics problems ranging from excitation of whistler structures to plasma turbulence especially, exploring the linear and nonlinear aspects of electron temperature gradient(ETG) driven turbulence, plasma transport over the entire cross section of LVPD. The machine operates in a pulsed mode with repetition cycle of 1 Hz and acquisition pulse length of duration of 15 ms, presently, LVPD has VXI data acquisition system but this is now in phasing out mode because of non-functioning of its various amplifier stages, expandability and unavailability of service support. The VXI system has limited capabilities to meet new experimental requirements in terms of numbers of channel (16), bit resolutions (8 bit), record length (30K points) and calibration support. Recently, integration of new acquisition system for simultaneous sampling of 40 channels of data, collected over multiple time scales with high speed is successfully demonstrated, by configuring latest available hardware and in-house developed software solutions. The operational feasibility provided by LabVIEW platform is not only for operating DAQ system but also for providing controls to various subsystems associated with the device. The new system is based on PXI express instrumentation bus and supersedes the existing VXI based data acquisition system in terms of instrumentation capabilities. This system has capability to measure 32 signals at 60 MHz sampling frequency and 8 signals with 1.25 GHz with 10 bit and 12 bit resolution capability for amplitude measurements. The PXI based system successfully addresses and demonstrate the issues concerning high channel count, high speed data streaming and multiple I/O modules synchronization. The system consists of chassis (NI 1085), 4 high sampling digitizers (NI 5105), 2 very high sampling digitizers (NI 5162), data streaming RAID drive (NI

  1. Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

    Directory of Open Access Journals (Sweden)

    Cécile Fanget

    Full Text Available The aim of this study was to correlate placental volumes deduced from three-dimensional ultrasound and virtual organ computer-aided analysis (VOCAL software with systemic concentrations of D-dimer and soluble endothelial protein C receptor (sEPCR.This was a monocentric experimental prospective study conducted from October 2008 to July 2009. Forty consecutive patients at risk of placental vascular pathology (PVP recurrence or occurrence were included. Placental volumes were systematically measured three times (11-14, 16-18 and 20-22 weeks of gestation (WG by two independent sonographers. D-dimers and sEPCR plasma concentrations were measured using ELISA kits (Enzyme Linked ImmunoSorbent Assay.Eleven patients had a PVP. The plasma D-dimer level was positively correlated with placental volume (r = 0.45, p < 0.001. A smaller placental volume and placental quotient was evidenced in women who developed a PVP at the three gestational ages, and the difference was more pronounced during the third exam (20 WG. No obvious correlation could be demonstrated between the development of a PVP and the levels of D-dimer and sEPCR. There was no significant difference in the values of placental volumes measured by the two sonographers.The placenta growth could be a major determinant of the elevation of D-dimer during pregnancy. Consideration of placental volume could allow for modulation of the D-dimer concentrations for restoring their clinical interest.

  2. Intravascular volume in cirrhosis. Reassessment using improved methodology

    International Nuclear Information System (INIS)

    Rector, W.G. Jr.; Ibarra, F.

    1988-01-01

    Previous studies of blood volume (BV) in cirrhosis have either not adjusted BV properly for body size; determined plasma volume from the dilution of labeled albumin 10-20 min postinjection, when some extravascular redistribution has already occurred; and/or not used the correct whole body-peripheral hematocrit ratio (0.82) in calculating whole BV from plasma volume and the peripheral hematocrit. We measured BV with attention to these considerations in 19 patients with cirrhosis and reexamined the determinants of vascular volume and the relationship between vascular volume and sodium retention. BV was calculated as plasma volume (determined from extrapolated plasma activity of intravenously injected [ 131 I]+albumin at time 0) divided by (peripheral hematocrit X 0.82). The result was expressed per kilogram dry body weight, determined by subtracting the mass of ascites (measured by isotope dilution; 1 liter = 1 kg) from the actual body weight of nonedematous patients. Measured and expressed in this way, BV correlated strongly with esophageal variceal size (r = 0.87, P less than 0.05), although not with net portal, right atrial, inferior vena caval, or arterial pressure, and was significantly greater in patients with sodium retention as compared to patients without sodium retention. The principal modifier of vascular volume in cirrhosis is vascular capacity, which is probably mainly determined by the extent of the portasystemic collateral circulation. Increased vascular volume in patients with sodium retention as compared to patients without sodium retention supports the overflow theory of ascites formation

  3. Plasma confinement

    CERN Document Server

    Hazeltine, R D

    2003-01-01

    Detailed and authoritative, this volume examines the essential physics underlying international research in magnetic confinement fusion. It offers readable, thorough accounts of the fundamental concepts behind methods of confining plasma at or near thermonuclear conditions. Designed for a one- or two-semester graduate-level course in plasma physics, it also represents a valuable reference for professional physicists in controlled fusion and related disciplines.

  4. Regulatory volume decrease in Leishmania mexicana: effect of anti-microtubule drugs

    Directory of Open Access Journals (Sweden)

    Francehuli Dagger

    2013-02-01

    Full Text Available The trypanosomatid cytoskeleton is responsible for the parasite's shape and it is modulated throughout the different stages of the parasite's life cycle. When parasites are exposed to media with reduced osmolarity, they initially swell, but subsequently undergo compensatory shrinking referred to as regulatory volume decrease (RVD. We studied the effects of anti-microtubule (Mt drugs on the proliferation of Leishmania mexicana promastigotes and their capacity to undergo RVD. All of the drugs tested exerted antiproliferative effects of varying magnitudes [ansamitocin P3 (AP3> trifluoperazine > taxol > rhizoxin > chlorpromazine]. No direct relationship was found between antiproliferative drug treatment and RVD. Similarly, Mt stability was not affected by drug treatment. Ansamitocin P3, which is effective at nanomolar concentrations, blocked amastigote-promastigote differentiation and was the only drug that impeded RVD, as measured by light dispersion. AP3 induced 2 kinetoplasts (Kt 1 nucleus cells that had numerous flagella-associated Kts throughout the cell. These results suggest that the dramatic morphological changes induced by AP3 alter the spatial organisation and directionality of the Mts that are necessary for the parasite's hypotonic stress-induced shape change, as well as its recovery.

  5. [Blood plasma volume dynamics in monkeys during immersion].

    Science.gov (United States)

    Krotov, V P; Burkovskaia, T E; Dotsenko, M A; Gordeev, Iu V; Nosovskiĭ, A M; Chel'naia, N A

    2004-01-01

    Dynamics of blood plasma volume (PV) was studied with indirect methods (hematocrit count, hemoglobin, total protein and high-molecular protein) during 9-d immersion of monkeys Macaca mulatta. The animals were donned in waterproof suits, motor restrained in space seat liners and immersed down to the xiphisternum. Two monkeys were immersed in the bath at one time. The suits were changed every day under ketamine (10 mg/kg of body mass). There were two groups with 12 animals in each. The first group was kept in the bath 3 days and the second--9 days. Prior to the experiment, the animals had been trained to stay in the seat liner put down into the dry bath. It was shown that already two days of exposure to the hydrostatic forces (approximately 15 mm Hg) and absence of negative pressure breathing reduced PV by 18-20% on the average in all animals. Subsequent PV dynamics was individual by character; however, PV deficit persisted during 4 days of immersion in the whole group. In this period, albumin filtration was increased significantly, whereas high-molecular protein filtration was increased to a less degree. During the remaining days in immersion PV regained normal values. Ten days of readaptation (reclined positioning of monkeys brought back into cage) raised VP beyond baseline values. This phenomenon can be attributed to the necessity to provide appropriate venous return and sufficient blood supply of organs and tissues following extension of blood vessels capacity.

  6. 'Memory' and sustention of microdischarges in a steady-state DBD: volume plasma or surface charge?

    International Nuclear Information System (INIS)

    Akishev, Yuri; Aponin, Gregory; Balakirev, Anton; Grushin, Mikhail; Karalnik, Vladimir; Petryakov, Alexander; Trushkin, Nikolay

    2011-01-01

    The results of a numerical study on the spatio-temporal behavior of transient microdischarges (MDs) in a steady-state dielectric barrier discharge (DBD) excited by a sinusoidal voltage are presented. MDs have a spatial 'memory'-every subsequent MD appears at exactly the same location occupied by the MD at the preceding half-period (HP). In the majority of cases each MD appears at its location only once during every HP. For such a case, the memory effect is not attributed to the residual surface charge deposited by the preceding MD but determined by the residual MD plasma column shunting the gap right up to the beginning of the next HP. In contrast to good memory in space, each individual MD has a large scatter with time in its appearance within every HP, i.e. there is no 'memory' concerning the phase of an applied voltage. This MD jittering within the period is attributed to the stochastic nature of partial surface breakdowns around the bases of the MD plasma column. Numerical calculations show that surface breakdown provides an MD current splash at every HP. Hence, in the steady-state DBD, the volume plasma is responsible for the existence of MD spatial 'memory' (i.e. where the MD appears), and the deposited surface charge is responsible for MD jittering in time (i.e. when the MD appears).

  7. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy.

    Science.gov (United States)

    Burnett, T L; Kelley, R; Winiarski, B; Contreras, L; Daly, M; Gholinia, A; Burke, M G; Withers, P J

    2016-02-01

    Ga(+) Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga(+) FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe(+) Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC-Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga(+) FIB milling WC-Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60nA at 30kV. Xe(+) PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  8. The hot plasma environment at jupiter: ulysses results.

    Science.gov (United States)

    Lanzerotti, L J; Armstrong, T P; Gold, R E; Anderson, K A; Krimigis, S M; Lin, R P; Pick, M; Roelof, E C; Sarris, E T; Simnett, G M; Maclennan, C G; Choo, H T; Tappin, S J

    1992-09-11

    Measurements of the hot plasma environment during the Ulysses flyby of Jupiter have revealed several new discoveries related to this large rotating astrophysical system. The Jovian magnetosphere was found by Ulysses to be very extended, with the day-side magnetopause located at approximately 105 Jupiter radii. The heavy ion (sulfur, oxygen, and sodium) population in the day-side magnetosphere increased sharply at approximately 86 Jupiter radii. This is somewhat more extended than the "inner" magnetosphere boundary region identified by the Voyager hot plasma measurements. In the day-side magnetosphere, the ion fluxes have the anisotropy direction expected for corotation with the planet, with the magnitude of the anisotropy increasing when the spacecraft becomes more immersed in the hot plasma sheet. The relative abundances of sulfur, oxygen, and sodium to helium decreased somewhat with decreasing radial distance from the planet on the day-side, which suggests that the abundances of the Jupiter-derived species are dependent on latitude. In the dusk-side, high-latitude region, intense fluxes of counter-streaming ions and electrons were discovered from the edge of the plasma sheet to the dusk-side magnetopause. These beams of electrons and ions were found to be very tightly aligned with the magnetic field and to be superimposed on a time- and space-variable isotropic hot plasma background. The currents carried by the measured hot plasma particles are typically approximately 1.6 x 10(-4) microamperes per square meter or approximately 8 x 10(5) amperes per squared Jupiter radius throughout the high-latitude magnetosphere volume. It is likely that the intense particle beams discovered at high Jovian latitudes produce auroras in the polar caps of the planet.

  9. Implementation of a simple electronic transfusion alert system decreases inappropriate ordering of packed red blood cells and plasma in a multi-hospital health care system.

    Science.gov (United States)

    Smith, Matthew; Triulzi, Darrell J; Yazer, Mark H; Rollins-Raval, Marian A; Waters, Jonathan H; Raval, Jay S

    2014-12-01

    Prescriber adherence to institutional blood component ordering guidelines can be low. The goal of this study was to decrease red blood cell (RBC) and plasma orders that did not meet institutional transfusion guidelines by using data within the laboratory information system to trigger alerts in the computerized order entry (CPOE) system at the time of order entry. At 10 hospitals within a regional health care system, discernment rules were created for RBC and plasma orders utilizing transfusion triggers of hemoglobin 1.6, respectively, with subsequent alert generation that appears within the CPOE system when a prescriber attempts to order RBCs or plasma on a patient whose antecedent laboratory values do not suggest that a transfusion is indicated. Orders and subsequent alerts were tracked for RBCs and plasma over evaluation periods of 15 and 10 months, respectively, along with the hospital credentials of the ordering health care providers (physician or nurse). Alerts triggered which were heeded remained steady and averaged 11.3% for RBCs and 19.6% for plasma over the evaluation periods. Overall, nurses and physicians canceled statistically identical percentages of alerted RBC (10.9% vs. 11.5%; p = 0.78) and plasma (21.3% vs. 18.7%; p = 0.22) orders. Implementing a simple evidence-based transfusion alert system at the time of order entry decreased non-evidence based transfusion orders by both nurse and physician providers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Dry etching of LaNiO3 thin films using inductively coupled plasma

    International Nuclear Information System (INIS)

    Kim, Gwan-Ha; Kim, Dong-Pyo; Kim, Kyoung-Tae; Kim, Chang-Il; Lee, Cheol-In; Kim, Tae-Hyung

    2006-01-01

    The etching characteristics of LaNiO 3 (LNO) thin films and SiO 2 in Cl 2 /Ar plasma were investigated. LNO etch rates decreased with increasing Cl 2 fraction in Ar plasma and the working pressure. Langmuir probe measurement showed a noticeable influence of Cl 2 /Ar mixing ratio on electron temperature, electron density, and ion current density. The modeling of volume kinetics for charged particles and OES measurements for neutral atoms indicated monotonous changes of both densities and fluxes of active species such as chlorine atoms and positive ions. The LNO etch rate behavior may be explained by physical mechanisms

  11. Vol. 6: Plasma Physics

    International Nuclear Information System (INIS)

    Sitenko, A.

    1993-01-01

    Problems of modern physics and the situation with physical research in Ukraine are considered. Programme of the conference includes scientific and general problems. Its proceeding are published in 6 volumes. The papers presented in this volume refer to plasma physics

  12. Study of emission of a volume nanosecond discharge plasma in xenon, krypton and argon at high pressures

    International Nuclear Information System (INIS)

    Baksht, E Kh; Lomaev, Mikhail I; Rybka, D V; Tarasenko, Viktor F

    2006-01-01

    The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude-time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ∼45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ∼130 ns. (laser applications and other topics in quantum electronics)

  13. Decreased left middle temporal gyrus volume in antipsychotic drug-naive, first-episode schizophrenia patients and their healthy unaffected siblings.

    Science.gov (United States)

    Hu, Maorong; Li, Jun; Eyler, Lisa; Guo, Xiaofeng; Wei, Qingling; Tang, Jingsong; Liu, Feng; He, Zhong; Li, Lihua; Jin, Hua; Liu, Zhening; Wang, Juan; Liu, Fang; Chen, Huafu; Zhao, Jingping

    2013-03-01

    The shared neuropathological characteristics of patients with schizophrenia and their siblings might represent intermediate phenotypes that could be used to investigate genetic susceptibility to the illness. We sought to discover gray matter volume differences in patients with schizophrenia and their unaffected siblings with voxel-based morphometry (VBM). We recruited antipsychotic drug-naive, first-episode schizophrenia (FES) patients, their unaffected siblings and age-, sex- and handedness-matched healthy controls. We used VBM to investigate differences in gray matter volume among the 3 groups. There were significant gray matter volumetric differences among the 3 groups in bilateral hippocampal and parahippocampal gyri, bilateral middle temporal gyri, and superior temporal gyri (FDR ptemporal gyrus, and volume of this region was not different between siblings and patients. Our findings confirm and extend previous VBM analyses in schizophrenia and it indicate that schizophrenia may be characterized by an abnormal development of cerebral lateralization. Furthermore, these data argue that patients and their unaffected siblings might share decreases in the gray matter volume of the left middle temporal gyrus, and this regional reduction might be a potential endophenotype for schizophrenia. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Tumor Volume Decrease via Feeder Occlusion for Treating a Large, Firm Trigone Meningioma.

    Science.gov (United States)

    Nakashima, Takuma; Hatano, Norikazu; Kanamori, Fumiaki; Muraoka, Shinsuke; Kawabata, Teppei; Takasu, Syuntaro; Watanabe, Tadashi; Kojima, Takao; Nagatani, Tetsuya; Seki, Yukio

    2018-01-01

    Trigone meningiomas are considered a surgical challenge, as they tend to be considerably large and hypervascularized at the time of presentation. We experienced a case of a large and very hard trigone meningioma that was effectively treated using initial microsurgical feeder occlusion followed by surgery in stages. A 19-year-old woman who presented with loss of consciousness was referred to our hospital for surgical treatment of a brain tumor. Radiological findings were compatible with a left ventricular trigone meningioma extending laterally in proximity to the Sylvian fissure. At initial surgery using the transsylvian approach, main feeders originating from the anterior and lateral posterior choroidal arteries were occluded at the inferior horn; however, only a small section of the tumor could initially be removed because of its firmness. Over time, feeder occlusion resulted in tumor necrosis and a 20% decrease in its diameter; the mass effect was alleviated within 1 year. The residual meningioma was then totally excised in staged surgical procedures after resection became more feasible owing to ischemia-induced partial softening of the tumor. When a trigone meningioma is large and very hard, initial microsurgical feeder occlusion in the inferior horn can be a safe and effective option, and can lead to necrosis, volume decrease, and partial softening of the residual tumor to allow for its staged surgical excision.

  15. Alterations in the regulatory volume decrease (RVD) and swelling-activated Cl- current associated with neuroendocrine differentiation of prostate cancer epithelial cells.

    NARCIS (Netherlands)

    Lemonnier, L.; Lazarenko, R.; Shuba, Y.; Thebault, S.C.; Roudbaraki, M.; Lepage, G.; Prevarskaya, N.; Skryma, R.

    2005-01-01

    Neuroendocrine (NE) differentiation of prostate epithelial/basal cells is a hallmark of advanced, androgen-independent prostate cancer, for which there is no successful therapy. Here we report for the first time on alterations in regulatory volume decrease (RVD) and its key determinant,

  16. Impact of plasma triangularity and collisionality on electron heat transport in TCV L-mode plasmas

    International Nuclear Information System (INIS)

    Camenen, Y.; Pochelon, A.; Behn, R.; Bottino, A.; Bortolon, A.; Coda, S.; Karpushov, A.; Sauter, O.; Zhuang, G.

    2007-01-01

    The impact of plasma shaping on electron heat transport is investigated in TCV L-mode plasmas. The study is motivated by the observation of an increase in the energy confinement time with decreasing plasma triangularity which may not be explained by a change in the temperature gradient induced by changes in the geometry of the flux surfaces. The plasma triangularity is varied over a wide range, from positive to negative values, and various plasmas conditions are explored by changing the total electron cyclotron (EC) heating power and the plasma density. The mid-radius electron heat diffusivity is shown to significantly decrease with decreasing triangularity and, for similar plasma conditions, only half of the EC power is required at a triangularity of -0.4 compared with +0.4 to obtain the same temperature profile. Besides, the observed dependence of the electron heat diffusivity on the electron temperature, electron density and effective charge can be grouped in a unique dependence on the plasma effective collisionality. In summary, the electron heat transport level exhibits a continuous decrease with decreasing triangularity and increasing collisionality. Local gyro-fluid and global gyro-kinetic simulations predict that trapped electron modes are the most unstable modes in these EC heated plasmas with an effective collisionality ranging from 0.2 to 1. The modes stability dependence on the plasma triangularity is investigated

  17. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  18. Renal blood flow, early distal sodium, and plasma renin concentrations during osmotic diuresis

    DEFF Research Database (Denmark)

    Leyssac, P P; Holstein-Rathlou, N H; Skøtt, O

    2000-01-01

    .6 mmHg. Urine flow increased 10-fold, and sodium excretion increased by 177%. Plasma renin concentration (PRC) increased by 58%. Renal blood flow and glomerular filtration rate decreased, however end-proximal flow remained unchanged. After a similar volume of hypotonic glucose (152 mM), ED......(NaCl) increased by 3.6 mM, (P renal hemodynamics, urine flow, sodium excretion rate, or PRC. Infusion of 300 micromol NaCl in a smaller volume caused ED(NaCl) to increase by 6.4 mM without significant changes in PRC. Urine flow and sodium excretion increased significantly...

  19. Increased concentration of vasopressin in plasma of essential fatty acid-deficient rats

    DEFF Research Database (Denmark)

    Hansen, Harald S.; Jensen, B.; Warberg, J.

    1985-01-01

    The effect of essential fatty acid deficiency (EFA-D) on the plasma concentration of arginine-vasopressin (AVP) and the urinary AVP excretion was investigated. Weanling rats were fed a fat-free diet (FF-rats). Control rats received the same diet in which 6% by wt. of sucrose was replaced by arachis...... oil. After 4-6 weeks of feeding, urine and plasma were analysed for AVP, osmolality, sodium and potassium. When compared to control rats FF-rats had decreased urine volume (6.0 ± 1.6 ml/24 hr versus 11.7 ± 3.2 ml/24 hr), increased urine osmolality (2409 ± 691 mOsm/kg versus 1260 ± 434 m...

  20. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  1. Plasma opening switch experiments on supermite

    International Nuclear Information System (INIS)

    Mendel, C.W.; Quintenz, J.P.; Rosenthal, S.E.; Savage, M.E.

    1988-01-01

    Experiments using plasma opening switches with fast field coils and plasmas injected on slow magnetic fields are described. Data showing the measurement of the field penetration into the volume that initially held the plasma fill will be shown. Assuming the plasma is mostly pushed back from the coil, rather than being penetrated by the magnetic field allows the density to be calculated, and gives densities of a few times 10 13 cm -3 for our usual operating range. The data makes it clear that the switch is open well before the initial plasma volume is completely penetrated by the magnetic fields. Additional measurements relating to the magnetic field penetration distance and physical penetration mechanism are presented. Other data presented show a magnetic insulation problem which must be solved before very large voltage multiplication can be accomplished with sufficient switch efficiency

  2. Recombinant erythropoietin acutely decreases renal perfusion and decouples the renin-angiotensin-aldosterone system.

    Science.gov (United States)

    Aachmann-Andersen, Niels J; Christensen, Soren J; Lisbjerg, Kristian; Oturai, Peter; Johansson, Pär I; Holstein-Rathlou, Niels-Henrik; Olsen, Niels V

    2018-03-01

    The effect of recombinant erythropoietin (rhEPO) on renal and systemic hemodynamics was evaluated in a randomized double-blinded, cross-over study. Sixteen healthy subjects were tested with placebo, or low-dose rhEPO for 2 weeks, or high-dose rhEPO for 3 days. Subjects refrained from excessive salt intake, according to instructions from a dietitian. Renal clearance studies were done for measurements of renal plasma flow, glomerular filtration rate (GFR) and the segmentel tubular handling of sodium and water (lithium clearance). rhEPO increased arterial blood pressure, total peripheral resistance, and renal vascular resistance, and decreased renal plasma flow in the high-dose rhEPO intervention and tended to decrease GFR. In spite of the decrease in renal perfusion, rhEPO tended to decrease reabsorption of sodium and water in the proximal tubule and induced a prompt decrease in circulating levels of renin and aldosterone, independent of changes in red blood cell mass, blood volumes, and blood pressure. We also found changes in biomarkers showing evidence that rhEPO induced a prothrombotic state. Our results suggest that rhEPO causes a direct downregulation in proximal tubular reabsorption that seems to decouple the activity of the renin-angiotensin-aldosterone system from changes in renal hemodynamics. This may serve as a negative feed-back mechanism on endogenous synthesis of EPO when circulating levels of EPO are high. These results demonstrates for the first time in humans a direct effect of rhEPO on renal hemodynamics and a decoupling of the renin-angiotensin-aldosterone system. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  3. Microwave Production of Steady State Large Volume Air Plasmas

    National Research Council Canada - National Science Library

    Brandenburg, John

    1999-01-01

    ...) and these plasmas persist for hundreds of milliseconds after power is turned off. These plasmas can be made in an inexpensive and easy to build apparatus based around a microwave oven operating at approximately 1kW and 2.45GHz...

  4. Magnetic helicity balance in the Sustained Spheromak Plasma Experiment

    International Nuclear Information System (INIS)

    Stallard, B.W.; Hooper, E.B.; Woodruff, S.; Bulmer, R.H.; Hill, D.N.; McLean, H.S.; Wood, R.D.

    2003-01-01

    The magnetic helicity balance between the helicity input injected by a magnetized coaxial gun, the rate-of-change in plasma helicity content, and helicity dissipation in electrode sheaths and Ohmic losses have been examined in the Sustained Spheromak Plasma Experiment (SSPX) [E. B. Hooper, L. D. Pearlstein, and R. H. Bulmer, Nucl. Fusion 39, 863 (1999)]. Helicity is treated as a flux function in the mean-field approximation, allowing separation of helicity drive and losses between closed and open field volumes. For nearly sustained spheromak plasmas with low fluctuations, helicity balance analysis implies a decreasing transport of helicity from the gun input into the spheromak core at higher spheromak electron temperature. Long pulse discharges with continuously increasing helicity and larger fluctuations show higher helicity coupling from the edge to the spheromak core. The magnitude of the sheath voltage drop, inferred from cathode heating and a current threshold dependence of the gun voltage, shows that sheath losses are important and reduce the helicity injection efficiency in SSPX

  5. Introduction of enteral food increases plasma GLP-2 and decreases GLP-2 receptor mRNA abundance during pig development

    DEFF Research Database (Denmark)

    Petersen, Y. M.; Hartmann, B.; Holst, Jens Juul

    2003-01-01

    increased before birth, peaked in suckling 1-d-old pigs (87 +/- 14 pmol/L, P anorexia (34 +/- 5 pmol/L, P ... in these pigs. We conclude that the introduction of enteral feeding transiently increases plasma GLP-2 concentrations and decreases small intestinal GLP-2R mRNA levels during pig development. GLP-2 may play a role in the growth of the small intestine around birth and weaning via a response to enteral nutrition....

  6. Particle melting and particle/plasma interactions in DC and RF plasmas: a modeling study. (Volumes I and II)

    International Nuclear Information System (INIS)

    Wei, D.Y.C.

    1987-01-01

    Integral process models were developed to predict particle melting in both DC and RF plasmas. Specifically, a numerical model has been developed to predict the temperature history of particles injected in a low pressure DC plasma jet. The temperature and velocity fields of the plasma jet are predicted as a free jet by solving the parabolized Navier-Stokes equations using a spatial marching scheme. Correction factors were introduced to take into account non continuum effects encountered in the low pressure environment. The plasma jet profiles as well as the particle/plasma interactions under different jet pressure ratios (from underexpanded to overexpanded) were investigated. The flow and temperature fields in the RF plasma torch are calculated using the axisymmetric Navier-Stokes equations based on the primitive variables, along with pseudo two-dimensional electromagnetic field equations. Particle trajectories and heat transfer characteristics in both DC and RF plasmas are calculated using predicted plasma jet profiles. Particle melting efficiencies in both DC and RF plasmas are evaluated and compared using model alloy systems. Based on the theoretical considerations, an alternative route of plasma spraying process (hybrid plasma spraying process) is proposed. An evaluation of particle melting in hybrid plasma jets had indicated that further improvement in deposit properties could be made

  7. Miniature Coaxial Plasma injector Diagnostics by Beam Plasma Interaction

    International Nuclear Information System (INIS)

    El-Tayeb, H.; El-Gamal, H.

    2003-01-01

    A miniature coaxial gun has been used to study the interaction between plasma beam and low density plasma formed in glow discharge. The peak discharge current flow between the coaxial electrodes was 5.25 kA as a single pulse with pulse width of 60 mu. Investigations are carried out with argon gas at pressure 0.4 Torr. The plasma stream ejected from the coaxial discharge propagates in the neutral argon atoms with mean velocity of 1.2x10 5 cm/s. The plasma stream temperature and density were 4.2 eV and 2.4x10 13 cm -3 respectively. An argon negative glow has been used as base plasma where its electron temperature and density were 2.2 eV and 6.2x10 7 cm -3 respectively. When the plasma stream propagates through the negative glow discharge region its velocity decreased to 8.8 x 10 4 cm/s and also the plasma electron temperature decreased to 3.1 eV, while the stream density remained the same. An excited wave appeared on the electric probe having frequency equal to the plasma frequency of the plasma under consideration. Simulation of the problem showed that this method could be applied for plasma diagnostics within the region of investigation. Those further studies for high temperature, dense, and magnetized plasma will be considered

  8. Paper-based plasma sanitizers.

    Science.gov (United States)

    Xie, Jingjin; Chen, Qiang; Suresh, Poornima; Roy, Subrata; White, James F; Mazzeo, Aaron D

    2017-05-16

    This work describes disposable plasma generators made from metallized paper. The fabricated plasma generators with layered and patterned sheets of paper provide a simple and flexible format for dielectric barrier discharge to create atmospheric plasma without an applied vacuum. The porosity of paper allows gas to permeate its bulk volume and fuel plasma, while plasma-induced forced convection cools the substrate. When electrically driven with oscillating peak-to-peak potentials of ±1 to ±10 kV, the paper-based devices produced both volume and surface plasmas capable of killing microbes. The plasma sanitizers deactivated greater than 99% of Saccharomyces cerevisiae and greater than 99.9% of Escherichia coli cells with 30 s of noncontact treatment. Characterization of plasma generated from the sanitizers revealed a detectable level of UV-C (1.9 nW⋅cm -2 ⋅nm -1 ), modest surface temperature (60 °C with 60 s of activation), and a high level of ozone (13 ppm with 60 s of activation). These results deliver insights into the mechanisms and suitability of paper-based substrates for active antimicrobial sanitization with scalable, flexible sheets. In addition, this work shows how paper-based generators are conformable to curved surfaces, appropriate for kirigami-like "stretchy" structures, compatible with user interfaces, and suitable for sanitization of microbes aerosolized onto a surface. In general, these disposable plasma generators represent progress toward biodegradable devices based on flexible renewable materials, which may impact the future design of protective garments, skin-like sensors for robots or prosthetics, and user interfaces in contaminated environments.

  9. Acute Experimental Hyperthyroidism Does Not Affect Basal and Volume-Induced Atrial Natriuretic Peptide Secretion in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Gregory Giamouzis

    2011-01-01

    Full Text Available Background. Excess circulating thyroid hormones are associated with increased cardiac atrial natriuretic peptide (ANP secretion but the exact mechanisms involved have not been fully elucidated in vivo. Methods. To examine whether thyroid hormone regulation of ANP secretion is the result of a direct action on the myocardium and/or of an indirect action through alterations in the peripheral circulation, plasma ANP levels (baseline and volume expansion-induced were evaluated in 14 healthy men, before and after triiodothyronine (T3 administration. Results. T3 administration was followed by a significant increase in serum T3 levels and a significant decrease in serum TSH levels, without significantly affecting ANP levels. Systemic vascular resistance, plasma rennin activity (PRA, and aldosterone (ALDO levels, as well as indices of left atrial function, were not significantly altered, despite a significant increase in cardiac output. Plasma volume expansion, induced by a 1500 ml normal saline (NSal infusion, both before and after T3 administration, was followed by a significant decrease in PRA and ALDO and a significant increase in plasma ANP levels, without significantly affecting the mean blood pressure (BP and heart rate (HR in each study period. The NSal-induced response, measured as the integrated area under the curve corrected for baseline values (-AUC, was not different after T3 administration for ANP, ALDO, PRA, HR, and mean BP. Conclusion. In vivo thyroid hormone-induced myocardial ANP secretion is the result of an indirect action mainly through hemodynamic changes that increase atrial stretch.

  10. Effect of single aerosol droplets on plasma impedance in the inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Chan, George C.-Y., E-mail: gcchan@indiana.edu; Zhu, Zhenli; Hieftje, Gary M.

    2012-10-15

    The impedance of an inductively coupled plasma was indirectly monitored by two different means-through a RF-probe coil placed inside the torch housing and from tapping the phase-detector signal of the impedance-matching network. During single-droplet introduction, temporal spikes in both the RF-probe coil and the phase-detector signals were readily observed, indicating a momentary change in plasma impedance. The changes in plasma impedance were found to be due solely to plasma perturbation by droplet introduction, and not to an artifact caused by imperfect automatic impedance matching. The temporal changes in plasma impedance were found to be directly proportional to the temporally integrated atomic emission of hydrogen, which is assumed in turn to be directly proportional to the volume of the introduced droplet. A small satellite droplet, with an estimated diameter of 27 {mu}m (i.e., {approx} 10 pL in volume), caused a readily measurable change in plasma impedance. By assuming that the change in RF-probe voltage is directly proportional to the variation in RF power delivered by the load coil, the instantaneous power change coupled to the plasma during single-droplet introduction was estimated. Typical increases in peak RF power and total energy coupled to the plasma, for a single 50-{mu}m droplet introduction, were thereby estimated to be around 8 to 11 W and 0.03 to 0.04 J, respectively. This impedance change was also exploited as a trigger to signal the droplet-introduction event into the plasma. This trigger signal was obtained through a combination of the RF-probe and the phase-detector signals and offered typical jitter from 1 to 2 ms. With the proper choice of a trigger threshold, no trigger misfire resulted and the achievable efficiencies of the trigger signal were 99.95, 97.18 and 74.33% for plasma forward power levels of 900, 1200, and 1500 W, respectively. The baseline noise on the RF-probe coil and the phase-detector signals, which increase with plasma

  11. Plasma extraction rate and collection efficiency during therapeutic plasma exchange with Spectra Optia in comparison with Haemonetics MCS+.

    Science.gov (United States)

    Lambert, Catherine; Gericke, Marion; Smith, Richard; Hermans, Cedric

    2011-01-01

    For therapeutic plasma exchange (TPE), continuous and intermittent flow separators are known to be efficient. This study was undertaken to compare the performances of the Spectra Optia, a continuous flow centrifugal apheresis system recently developed by CaridianBCT, with the Haemonetics Multicomponents System (MCS)+ apheresis system based on intermittent flow centrifugation. The primary objective of the study was to compare the time required to exchange one total plasma volume with both separators. The secondary objectives were to determine the plasma exchange efficiency, the plasma extraction rate, the percentage of target exchange volume achieved, and the loss of cellular components. The study involved prospectively paired comparison of 16 TPE on each device performed in patients with chronic diseases treated with TPE. The time required to exchange 1 total plasma volume was 182 ± 36 minutes for MCS+ procedures and 100 ± 20 minutes for the Spectra Optia procedures (P higher plasma extraction rate was achieved (30.2 ± 4.3 vs 16.8 ± 3.4 mL/min, respectively, P exchange efficiency was slightly better with the Spectra Optia compared with the MCS+ procedures (83.4 ± 7.0 vs 80.0 ± 8.5%, P higher extraction rate and exchange efficiency than the MCS+ allowing to remove the same amount of plasma in less time, by processing less blood. It also removes significantly less platelets than the MCS+ separator. Copyright © 2010 Wiley-Liss, Inc.

  12. Decreased Expression of Na+/K+-ATPase, NHE3, NBC1, AQP1 and OAT in Gentamicin-induced Nephropathy

    Science.gov (United States)

    Bae, Woo Kyun; Lee, JongUn; Park, Jeong Woo; Bae, Eun Hui; Ma, Seong Kwon; Kim, Suhn Hee

    2008-01-01

    The present study was aimed to determine whether there is an altered regulation of tubular transporters in gentamicin-induced nephropathy. Sprague-Dawley male rats (200~250 g) were subcutaneously injected with gentamicin (100 mg/kg per day) for 7 days, and the expression of tubular transporters was determined by immunoblotting and immunohistochemistry. The mRNA and protein expression of OAT was also determined. Gentamicin-treated rats exhibited significantly decreased creatinine clearance along with increased plasma creatinine levels. Accordingly, the fractional excretion of sodium increased. Urine volume was increased, while urine osmolality and free water reabsorption were decreased. Immunoblotting and immunohistochemistry revealed decreased expression of Na+/K+-ATPase, NHE3, NBC1, and AQP1 in the kidney of gentamicin-treated rats. The expression of OAT1 and OAT3 was also decreased. Gentamicin-induced nephropathy may at least in part be causally related with a decreased expression of Na+/K+-ATPase, NHE3, NBC1, AQP1 and OAT. PMID:19967075

  13. Maternal high fat diet is associated with decreased plasma n-3 fatty acids and fetal hepatic apoptosis in nonhuman primates.

    Directory of Open Access Journals (Sweden)

    Wilmon F Grant

    2011-02-01

    Full Text Available To begin to understand the contributions of maternal obesity and over-nutrition to human development and the early origins of obesity, we utilized a non-human primate model to investigate the effects of maternal high-fat feeding and obesity on breast milk, maternal and fetal plasma fatty acid composition and fetal hepatic development. While the high-fat diet (HFD contained equivalent levels of n-3 fatty acids (FA's and higher levels of n-6 FA's than the control diet (CTR, we found significant decreases in docosahexaenoic acid (DHA and total n-3 FA's in HFD maternal and fetal plasma. Furthermore, the HFD fetal plasma n-6:n-3 ratio was elevated and was significantly correlated to the maternal plasma n-6:n-3 ratio and maternal hyperinsulinemia. Hepatic apoptosis was also increased in the HFD fetal liver. Switching HFD females to a CTR diet during a subsequent pregnancy normalized fetal DHA, n-3 FA's and fetal hepatic apoptosis to CTR levels. Breast milk from HFD dams contained lower levels of eicosopentanoic acid (EPA and DHA and lower levels of total protein than CTR breast milk. This study links chronic maternal consumption of a HFD with fetal hepatic apoptosis and suggests that a potentially pathological maternal fatty acid milieu is replicated in the developing fetal circulation in the nonhuman primate.

  14. Pomegranate (Punicagranatum juice decreases lipid peroxidation, but has no effect on plasma advanced glycated end-products in adults with type 2 diabetes: a randomized double-blind clinical trial

    Directory of Open Access Journals (Sweden)

    Golbon Sohrab

    2015-09-01

    Full Text Available Introduction: Diabetes mellitus characterized by hyperglycemia could increase oxidative stress and formation of advanced glycated end-products (AGEs, which contribute to diabetic complications. The purpose of this study was to assess the effect of pomegranate juice (PJ containing natural antioxidant on lipid peroxidation and plasma AGEs in patients with type 2 diabetes (T2D. Materials and methods: In a randomized, double-blind, placebo-controlled trial, 44 patients (age range 56±6.8 years, T2D were randomly assigned to one of two groups: group A (PJ, n=22 and group B (Placebo, n=22. At the baseline and the end of 12-week intervention, biochemical markers including fasting plasma glucose, insulin, oxidative stress, and AGE markers including carboxy methyl lysine (CML and pentosidine were assayed. Results: At baseline, there were no significant differences in plasma total antioxidant capacity (TAC levels between the two groups, but malondialdehyde (MDA decreased levels were significantly different (P<0.001. After 12 weeks of intervention, TAC increased (P<0.05 and MDA decreased (P<0.01 in the PJ group when compared with the placebo group. However, no significant differences were observed in plasma concentration of CML and pentosidine between the two groups. Conclusions: The study showed that PJ decreases lipid peroxidation. Therefore, PJ consumption may delay onset of T2D complications related to oxidative stress.

  15. Physics through the 1990s: Plasmas and fluids

    International Nuclear Information System (INIS)

    1986-01-01

    This survey of plasma physics and fluid physics briefly describes present activities and recent major accomplishments. It also identifies research areas that are likely to lead to advances during the next decade. Plasma physics is divided into three major areas: general plasma physics, fusion plasma confinement and heating, and space and astrophysical plasmas. Fluid physics is treated as one topic, although it is an extremely diverse research field ranging from biological fluid dynamics to ship and aircraft performance to geological fluid dynamics. Subpanels, chosen for their technical expertise and scientific breadth, reviewed each of the four areas. The entire survey was coordinated and supervised by an Executive Committee, which is also responsible for the Executive Summary of this volume. Wherever possible, input from recent Advisory Committees was used, e.g., from the Magnetic Fusion Advisory Committee, the Space Science Board, and the Astronomy Survey Committee. This volume is organized as follows: An Introduction and Executive Summary that outlines (1) major findings and recommendations; (2) significant research accomplishments during the past decade and likely areas of future research emphasis; and (3) a brief summary of present funding levels, manpower resources, and institutional involvement; and the subpanel reports constitute Fluid Physics, General Plasma Physics, Fusion Plasma Confinement and Heating, and Space and Astrophysical Plasmas. An important conclusion of this survey is that both plasma physics and fluid physics are scientifically and intellectually well developed, and both ares are broad subdisciplines of physics. We therefore recommend that future physics surveys have separate volumes on the physics of plasmas and the physics of fluids

  16. Dusty plasma phase in a steady state plasma device

    International Nuclear Information System (INIS)

    Liang Xiaoping; Zheng Jian; Ma Jinxiu; Liu Wangdong; Zhuang Ge; Xie Jinlin; Wang Congrong; Yu Changxuan

    2000-01-01

    A DC discharge dusty plasma device used for study of waves in dusty plasma is introduced. A dusty plasma column is produced with about 30 cm in length and about 8.4 cm in diameter. The electron saturation current of Langmuir probe is obviously decreasing while the dust grains are present in the plasma. The negative charge on dust grains is directly proportional to the rotation rate of the dispenser. And the dust grains carry up to 40% of the negative charges in the whole plasma

  17. Spider phobia is associated with decreased left amygdala volume: a cross-sectional study

    Science.gov (United States)

    2013-01-01

    Background Evidence from animal and human studies imply the amygdala as the most critical structure involved in processing of fear-relevant stimuli. In phobias, the amygdala seems to play a crucial role in the pathogenesis and maintenance of the disorder. However, the neuropathology of specific phobias remains poorly understood. In the present study, we investigated whether patients with spider phobia show altered amygdala volumes as compared to healthy control subjects. Methods Twenty female patients with spider phobia and twenty age-matched healthy female controls underwent magnetic resonance imaging to investigate amygdala volumes. The amygdalae were segmented using an automatic, model-based segmentation tool (FSL FIRST). Differences in amygdala volume were investigated by multivariate analysis of covariance with group as between-subject factor and left and right amygdala as dependent factors. The relation between amygdala volume and clinical features such as symptom severity, disgust sensitivity, trait anxiety and duration of illness was investigated by Spearman correlation analysis. Results Spider phobic patients showed significantly smaller left amygdala volume than healthy controls. No significant difference in right amygdala volume was detected. Furthermore, the diminished amygdala size in patients was related to higher symptom severity, but not to higher disgust sensitivity or trait anxiety and was independent of age. Conclusions In summary, the results reveal a relation between higher symptom severity and smaller left amygdala volume in patients with spider phobia. This relation was independent of other potential confounders such as the disgust sensitivity or trait anxiety. The findings suggest that greater spider phobic fear is associated with smaller left amygdala. However, the smaller left amygdala volume may either stand for a higher vulnerability to develop a phobic disorder or emerge as a consequence of the disorder. PMID:23442196

  18. Laser optically pumped by laser-produced plasma

    International Nuclear Information System (INIS)

    Silfvast, W.T.; Wood, O.R. II.

    1975-01-01

    Laser solids, liquids and gases are pumped by a new technique in which the output from an efficient molecular laser, such as a CO 2 laser, ionizes a medium, such as xenon, into a generally cylindrical plasma volume, in proximity to the pumped laser body. Breakdown yields a visible and ultraviolet-radiation-emitting plasma in that volume to pump the laser body. The spectral radiance of the plasma is significantly higher than that produced by a dc-discharge-heated plasma at nearly all wavelengths in the plasma spectrum. The risetime of radiation from the laser-produced plasma can also be significantly shorter than that of a dc heated plasma. A further advantage resides in the fact that in some applications the attenuating walls needed by flashlamps may be eliminated with the result that laser threshold is more readily reached. Traveling wave excitation may be provided by oblique incidence of the pumping laser beam through the ionizable medium to create sequential ionization of portions of that medium along the length of the pumped laser body. (auth)

  19. The loss-of-function disease-mutation G301R in the Na+/K+-ATPase α2 isoform decreases lesion volume and improves functional outcome after acute spinal cord injury in mice.

    Science.gov (United States)

    Ellman, Ditte Gry; Isaksen, Toke Jost; Lund, Minna Christiansen; Dursun, Safinaz; Wirenfeldt, Martin; Jørgensen, Louise Helskov; Lykke-Hartmann, Karin; Lambertsen, Kate Lykke

    2017-09-08

    The Na + /K + -ATPases are transmembrane ion pumps important for maintenance of ion gradients across the plasma membrane that serve to support multiple cellular functions, such as membrane potentials, regulation of cellular volume and pH, and co-transport of signaling transmitters in all animal cells. The α 2 Na + /K + -ATPase subunit isoform is predominantly expressed in astrocytes, which us the sharp Na + -gradient maintained by the sodium pump necessary for astroglial metabolism. Prolonged ischemia induces an elevation of [Na + ] i , decreased ATP levels and intracellular pH owing to anaerobic metabolism and lactate accumulation. During ischemia, Na + /K + -ATPase-related functions will naturally increase the energy demand of the Na + /K + -ATPase ion pump. However, the role of the α 2 Na + /K + -ATPase in contusion injury to the spinal cord remains unknown. We used mice heterozygous mice for the loss-of-function disease-mutation G301R in the Atp1a2 gene (α 2 +/G301R ) to study the effect of reduced α 2 Na + /K + -ATPase expression in a moderate contusion spinal cord injury (SCI) model. We found that α 2 +/G301R mice display significantly improved functional recovery and decreased lesion volume compared to littermate controls (α 2 +/+ ) 7 days after SCI. The protein level of the α 1 isoform was significantly increased, in contrast to the α 3 isoform that significantly decreased 3 days after SCI in both α 2 +/G301R and α 2 +/+ mice. The level of the α 2 isoform was significantly decreased in α 2 +/G301R mice both under naïve conditions and 3 days after SCI compared to α 2 +/+ mice. We found no differences in astroglial aquaporin 4 levels and no changes in the expression of chemokines (CCL2, CCL5 and CXCL1) and cytokines (TNF, IL-6, IL-1β, IL-10 and IL-5) between genotypes, just as no apparent differences were observed in location and activation of CD45 and F4/80 positive microglia and infiltrating leukocytes. Our proof of concept study

  20. Effect of antenna capacitance on the plasma characteristics of an internal linear inductively coupled plasma system

    International Nuclear Information System (INIS)

    Lim, Jong Hyeuk; Kim, Kyong Nam; Park, Jung Kyun; Yeom, Geun Young

    2008-01-01

    This study examined the effect of the antenna capacitance of an inductively coupled plasma (ICP) source, which was varied using an internal linear antenna, on the electrical and plasma characteristics of the ICP source. The inductive coupling at a given rf current increased with decreasing antenna capacitance. This was caused by a decrease in the inner copper diameter of the antenna made from coaxial copper/quartz tubing, which resulted in a higher plasma density and lower plasma potential. By decreasing the diameter of the copper tube from 25 to 10 mm, the plasma density of a plasma source size of 2750x2350 mm 2 was increased from approximately 8x10 10 /cm 3 to 1.5x10 11 /cm 3 at 15 mTorr Ar and 9 kW of rf power

  1. Plasma sterol evidence for decreased absorption and increased synthesis of cholesterol in insulin resistance and obesity.

    Science.gov (United States)

    Paramsothy, Pathmaja; Knopp, Robert H; Kahn, Steven E; Retzlaff, Barbara M; Fish, Brian; Ma, Lina; Ostlund, Richard E

    2011-11-01

    The rise in LDL with egg feeding in lean insulin-sensitive (LIS) participants is 2- and 3-fold greater than in lean insulin-resistant (LIR) and obese insulin-resistant (OIR) participants, respectively. We determined whether differences in cholesterol absorption, synthesis, or both could be responsible for these differences by measuring plasma sterols as indexes of cholesterol absorption and endogenous synthesis. Plasma sterols were measured by gas chromatography-mass spectrometry in a random subset of 34 LIS, 37 LIR, and 37 OIR participants defined by the insulin sensitivity index (S(I)) and by BMI criteria selected from a parent group of 197 participants. Cholestanol and plant sterols provide a measure of cholesterol absorption, and lathosterol provides a measure of cholesterol synthesis. The mean (±SD) ratio of plasma total absorption biomarker sterols to cholesterol was 4.48 ± 1.74 in LIS, 3.25 ± 1.06 in LIR, and 2.82 ± 1.08 in OIR participants. After adjustment for age and sex, the relations of the absorption sterol-cholesterol ratios were as follows: LIS > OIR (P LIR (P OIR (P = 0.11). Lathosterol-cholesterol ratios were 0.71 ± 0.32 in the LIS participants, 0.95 ± 0.47 in the LIR participants, and 1.29 ± 0.55 in the OIR participants. After adjustment for age and sex, the relations of lathosterol-cholesterol ratios were as follows: LIS sterol concentrations were positively associated with S(I) and negatively associated with obesity, whereas lathosterol correlations were the opposite. Cholesterol absorption was highest in the LIS participants, whereas cholesterol synthesis was highest in the LIR and OIR participants. Therapeutic diets for hyperlipidemia should emphasize low-cholesterol diets in LIS persons and weight loss to improve S(I) and to decrease cholesterol overproduction in LIR and OIR persons.

  2. Flavonol-rich dark cocoa significantly decreases plasma endothelin-1 and improves cognition in urban children.

    Science.gov (United States)

    Calderón-Garcidueñas, Lilian; Mora-Tiscareño, Antonieta; Franco-Lira, Maricela; Cross, Janet V; Engle, Randall; Aragón-Flores, Mariana; Gómez-Garza, Gilberto; Jewells, Valerie; Medina-Cortina, Humberto; Solorio, Edelmira; Chao, Chih-Kai; Zhu, Hongtu; Mukherjee, Partha S; Ferreira-Azevedo, Lara; Torres-Jardón, Ricardo; D'Angiulli, Amedeo

    2013-01-01

    Air pollution exposures are linked to systemic inflammation, cardiovascular and respiratory morbidity and mortality, neuroinflammation and neuropathology in young urbanites. In particular, most Mexico City Metropolitan Area (MCMA) children exhibit subtle cognitive deficits, and neuropathology studies show 40% of them exhibiting frontal tau hyperphosphorylation and 51% amyloid-β diffuse plaques (compared to 0% in low pollution control children). We assessed whether a short cocoa intervention can be effective in decreasing plasma endothelin 1 (ET-1) and/or inflammatory mediators in MCMA children. Thirty gram of dark cocoa with 680 mg of total flavonols were given daily for 10.11 ± 3.4 days (range 9-24 days) to 18 children (10.55 years, SD = 1.45; 11F/7M). Key metabolite ratios in frontal white matter and in hippocampus pre and during cocoa intervention were quantified by magnetic resonance spectroscopy. ET-1 significantly decreased after cocoa treatment (p = 0.0002). Fifteen children (83%) showed a marginally significant individual improvement in one or both of the applied simple short memory tasks. Endothelial dysfunction is a key feature of exposure to particulate matter (PM) and decreased endothelin-1 bioavailability is likely useful for brain function in the context of air pollution. Our findings suggest that cocoa interventions may be critical for early implementation of neuroprotection of highly exposed urban children. Multi-domain nutraceutical interventions could limit the risk for endothelial dysfunction, cerebral hypoperfusion, neuroinflammation, cognitive deficits, structural volumetric detrimental brain effects, and the early development of the neuropathological hallmarks of Alzheimer's and Parkinson's diseases.

  3. Effects of intravenous administration of two volumes of calcium solution on plasma ionized calcium concentration and recovery from naturally occurring hypocalcemia in lactating dairy cows.

    NARCIS (Netherlands)

    Doze, J.G.; Donders, R.; Kolk, J.H. van der

    2008-01-01

    OBJECTIVE: To compare the effects of administration of 2 volumes of a calcium solution (calcium oxide and calcium gluconate) on plasma ionized calcium concentration (PICaC) and clinical recovery from naturally occurring hypocalcemia (NOHC; milk fever) in lactating dairy cows. ANIMALS: 123 cows with

  4. Radio frequency plasma power dependence of the moisture permeation barrier characteristics of Al2O3 films deposited by remote plasma atomic layer deposition

    International Nuclear Information System (INIS)

    Jung, Hyunsoo; Choi, Hagyoung; Lee, Sanghun; Jeon, Heeyoung; Jeon, Hyeongtag

    2013-01-01

    In the present study, we investigated the gas and moisture permeation barrier properties of Al 2 O 3 films deposited on polyethersulfone films (PES) by capacitively coupled plasma (CCP) type Remote Plasma Atomic Layer Deposition (RPALD) at Radio Frequency (RF) plasma powers ranging from 100 W to 400 W in 100 W increments using Trimethylaluminum [TMA, Al(CH 3 ) 3 ] as the Al source and O 2 plasma as the reactant. To study the gas and moisture permeation barrier properties of 100-nm-thick Al 2 O 3 at various plasma powers, the Water Vapor Transmission Rate (WVTR) was measured using an electrical Ca degradation test. WVTR decreased as plasma power increased with WVTR values for 400 W and 100 W of 2.6 × 10 −4 gm −2 day −1 and 1.2 × 10 −3 gm −2 day −1 , respectively. The trends for life time, Al-O and O-H bond, density, and stoichiometry were similar to that of WVTR with improvement associated with increasing plasma power. Further, among plasma power ranging from 100 W to 400 W, the highest power of 400 W resulted in the best moisture permeation barrier properties. This result was attributed to differences in volume and amount of ion and radical fluxes, to join the ALD process, generated by O 2 plasma as the plasma power changed during ALD process, which was determined using a plasma diagnosis technique called the Floating Harmonic Method (FHM). Plasma diagnosis by FHM revealed an increase in ion flux with increasing plasma power. With respect to the ALD process, our results indicated that higher plasma power generated increased ion and radical flux compared with lower plasma power. Thus, a higher plasma power provides the best gas and moisture permeation barrier properties

  5. ECR Plasma Photos

    International Nuclear Information System (INIS)

    Racz, R.; Biri, S.; Palinkas, J.

    2009-01-01

    Complete text of publication follows. In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from He, methane, N, O, Ne, Ar, Kr, Xe gases and from their mixtures. The effects of the main external setting parameters (gas pressure, gas composition, magnetic field, microwave power, microwave frequency) were studied to the shape, color and structure of the plasma. The double frequency mode (9+14 GHz) was also realized and photos of this special 'star-in-star' shape plasma were recorded. A study was performed to analyze and understand the color of the ECR plasmas. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas. To our best knowledge our work is the first systematic study of ECR plasmas in the visible light region. When looking in the plasma chamber of an ECRIS we can see an axial image of the plasma (figure 1) in conformity with experimental setup. Most of the quantitative information was obtained through the summarised values of the Analogue Digital Unit (ADU) of pixels. By decreasing the strength of the magnetic trap we clearly observed that the brightness of the central part of the plasma gradually decreases, i.e. the plasma becomes more and more 'empty'. Figure 2 shows a photo series of ECR plasma at decreasing axial magnetic field. The radial size of the plasma increased because of the ascendant resonant zone. By increasing the power of the injected microwave an optimum (or at least saturation) was found in the brightness of the plasma. We found correlation between the gas dosing rates and plasma intensities. When sweeping the frequency of the microwave in a wide region

  6. Atomic and plasma-material interaction data for fusion. V. 6

    International Nuclear Information System (INIS)

    1995-01-01

    Volume 6 of the supplement ''atomic and plasma-material interaction data for fusion'' to the journal ''Nuclear Fusion'' includes critical assessments and results of original experimental and theoretical studies on inelastic collision processes among the basic and dominant impurity constituents of fusion plasmas. Processes considered in the 15 papers constituting this volume are: electron impact excitation of excited Helium atoms, electron impact excitation and ionization of plasma impurity ions and atoms, electron-impurity-ion recombination and excitation, ionization and electron capture in collisions of plasma protons and impurity ions with the main fusion plasma neutral components helium and atomic and molecular hydrogen. Refs, figs, tabs

  7. Labour analgesia with intrathecal fentanyl decreases maternal stress.

    Science.gov (United States)

    Cascio, M; Pygon, B; Bernett, C; Ramanathan, S

    1997-06-01

    Lumbar epidural analgesia (LEA) decreases maternal stress as measured by maternal circulating plasma catecholamine concentrations. Intrathecal fentanyl (ITF) provides effective labour analgesia but its effect on maternal epinephrine (Epi) and norepinephrine (NE) concentrations is not known. This study assesses whether ITF reduces maternal stress in the same manner as conventional LEA. Twenty-four healthy women in active labour received either 25 micrograms ITF (n = 12) or epidural lidocaine 1.5% (n = 12) for analgesia. Venous blood samples were collected before anaesthesia and at five minute intervals for 30 min following anaesthesia for the measurement of plasma Epi and NE by high performance liquid chromatography. Maternal blood pressure (BP), heart rate (HR), visual analog scores (VAS) to pain and pruritus were recorded at the same time. Both ITF and LEA decreased pain VAS scores, maternal BP, and plasma Epi concentrations with only minimal effects on plasma NE concentrations. Intrathecal fentanyl (ITF) and LEA reduced plasma epi to a similar extent, with ITF reducing the levels slightly faster than LEA. Intrathecal fentanyl(ITF) and LEA reduced plasma Epi concentrations by 52% and 51%, respectively (P value < 0.01). We conclude that ITF is as effective as LEA in producing pain relief in the labouring patient. Intrathecal Fentanyl (ITF) is also capable of reducing maternal plasma epinephrine concentration, thus avoiding the possibly deleterious side effects of excess amounts of this catecholamine during labour.

  8. Experimental study on plasma parameters in the mushroom limiter shadow in the T-10 tokamak

    International Nuclear Information System (INIS)

    Alferov, A.A.; Vershkov, V.A.; Grashin, S.A.; Chankin, A.V.

    1988-01-01

    Plasma parameters in the shadow of mashroom limiter installed in the lower tokamak outlet are studied. Investigation into asymmetry of plasma fluxes to the ion and electrone limiter sides leads to a consumption concerning two meachanisms of its occurrance-toroidal plasma rotation and prevailing plasma departure to the wall through the external torus encirclement. Asymmetry of plasma drift potentials near the limiter observed during the experiment leads to current drift through the limiter close to Spitzer j s one. It is shown that with the increase of mean plasma density the plasma density in the limiter channels grows and its temperature is decreased so the charged particle losses for the limiter are weakly dependent on the mean density which is connected with plasma confinement degradation under the density reduction. A complete flux of charged particles to the limiter is comparable to their flux from plasma filament. Plasma flux into the channels is close to ambipolar one and the power fluxes to neutralization plates are of the order of 10 j s Te/e. Neutral gas pressure dependence in the volume under the limiter on the plasma fluxes to channels is nonlinear, the maximum pressure achieves 3x10 -2 T

  9. Thermal plasma waste treatment

    International Nuclear Information System (INIS)

    Heberlein, Joachim; Murphy, Anthony B

    2008-01-01

    Plasma waste treatment has over the past decade become a more prominent technology because of the increasing problems with waste disposal and because of the realization of opportunities to generate valuable co-products. Plasma vitrification of hazardous slags has been a commercial technology for several years, and volume reduction of hazardous wastes using plasma processes is increasingly being used. Plasma gasification of wastes with low negative values has attracted interest as a source of energy and spawned process developments for treatment of even municipal solid wastes. Numerous technologies and approaches exist for plasma treatment of wastes. This review summarizes the approaches that have been developed, presents some of the basic physical principles, provides details of some specific processes and considers the advantages and disadvantages of thermal plasmas in waste treatment applications. (topical review)

  10. Decreased endogenous progesterone and ratio of progesterone to ...

    African Journals Online (AJOL)

    Progesterone and estrogen are two steroid hormones whose exposure may decrease the risk and delay the onset of ischemic stroke. The main objective of this study was to determine the plasma level of progesterone, estrogen and ratio of progesterone/estrogen in ischemic stroke patients. The plasma levels of ...

  11. Relative blood volume changes underestimate total blood volume changes during hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; Lub-de Hooge, Marjolijn N.; Pruim, Jan; Nijnuis, Hugo; Wiersum, Anneke; de Jong, Paul E.; Huisman, Roel M.; Franssen, Casper F. M.

    Background: Measurements of relative blood volume changes (ARBV) during hemodialysis (HD) are based on hemoconcentration and assume uniform mixing of erythrocytes and plasma throughout the circulation. However, whole-body hematocrit (Ht) is lower than systemic Ht. During HD, a change in the ratio

  12. The physics of non-ideal plasma

    CERN Document Server

    Fortov, Vladimir E

    2000-01-01

    This book is devoted to the physical properties of nonideal plasma which is compressed so strongly that the effects of interparticle interactions govern the plasma behavior. The interest in this plasma was generated by the development of modern technologies and facilities whose operations were based on high densities of energy. In this volume, the methods of nonideal plasma generation and diagnostics are considered. The experimental results are given and the main theoretical models of nonideal plasma state are discussed. The problems of thermodynamics, electro-physics, optics and dynamic stabi

  13. Visualization of plasma collision phenomenon by particle based rendering

    International Nuclear Information System (INIS)

    Yamamoto, Takeshi; Takagishi, Hironori; Hasegawa, Kyoko; Nakata, Susumu; Tanaka, Satoshi; Tanaka, Kazuo

    2012-01-01

    In this paper, we visualize plasma collision phenomenon based on XYT-space (space and time) volume data for supporting research in plasma physics. We create 3D volume data in the XYT-space by piling up a time series of XY-plane photo images taken in experiment. As a result, we can visualize as one still image all the time behavior of the plasma plume. Besides, we adopt 'fused' visualization based on particle based rendering technique. Using that technique, we can easily fuse volume rendering different materials, and compare physics of different elements in flexible ways. In addition, we propose the method to generate pseudo-3D images from pictures shoot by ICCD of two perspectives on the upper and side. (author)

  14. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  15. Decrease in platelet activating factor stimulated phosphoinositide turnover during storage of human platelets in plasma

    International Nuclear Information System (INIS)

    Carter, M.G.; Shukla, S.D.

    1987-01-01

    Human platelet concentrate from the American Red Cross Blood Center was stored at 24 degree C in a shaker and aliquots were taken out at time intervals aseptically. Platelet activating factor (PAF) stimulated turnover of phosphoinositide (PPI) was monitored by assaying 32 P incorporation into phosphoinositides using platelet rich plasma (PRP). Platelets in PRP were incubated with 1 x 10 -7 M PAF at 37 degree C with gentle shaking and after 5 min their lipids were extracted and analysed by TLC for 32 P-phosphoinositides. The percent stimulation of 32 P incorporation by PAF (over control) into PPI was approximately 250, 100, 60, 25 and 20 on days 1, 2, 3, 5 and 6, respectively. This indicated a dramatic decrease in PAF responsive turnover of platelet PPI during storage. These findings have important implications in relation to PAF receptor activity and viability of platelets at different periods of storage

  16. Whole body and tissue blood volumes of two strains of rainbow trout (Oncorhynchus mykiss)

    Science.gov (United States)

    Gingerich, W.H.; Pityer, R.A.; Rach, J.J.

    1990-01-01

    1. Estimates of apparent packed cell, plasma and total blood volumes for the whole body and for 13 selected tissues were compared between Kamloops and Wytheville strains of rainbow trout (Oncorhynchus mykiss) by the simultaneous injection of two vascular tracers, radiolabeled trout erythrocytes (51Cr-RBC) and radioiodated bovine serum albumin (125I-BSA).2. Whole body total blood volume, plasma volume and packed cell volume were slightly, but not significantly greater in the Wytheville trout, whereas, the apparent plasma volumes and total blood volumes in 4 of 13 tissues were significantly greater in the Kamloops strain.3. Differences were most pronounced in highly perfused organs, such as the liver and kidney and in organs of digestion such as the stomach and intestines.4. Differences in blood volumes between the two strains may be related to the greater permeability of the vascular membranes in the Kamloops strain fish.

  17. Fuel gas production by microwave plasma in liquid

    International Nuclear Information System (INIS)

    Nomura, Shinfuku; Toyota, Hiromichi; Tawara, Michinaga; Yamashita, Hiroshi; Matsumoto, Kenya

    2006-01-01

    We propose to apply plasma in liquid to replace gas-phase plasma because we expect much higher reaction rates for the chemical deposition of plasma in liquid than for chemical vapor deposition. A reactor for producing microwave plasma in a liquid could produce plasma in hydrocarbon liquids and waste oils. Generated gases consist of up to 81% hydrogen by volume. We confirmed that fuel gases such as methane and ethylene can be produced by microwave plasma in liquid

  18. Zinc oxide nanoparticles decrease the expression and activity of plasma membrane calcium ATPase, disrupt the intracellular calcium homeostasis in rat retinal ganglion cells.

    Science.gov (United States)

    Guo, Dadong; Bi, Hongsheng; Wang, Daoguang; Wu, Qiuxin

    2013-08-01

    Zinc oxide nanoparticle is one of the most important materials with diverse applications. However, it has been reported that zinc oxide nanoparticles are toxic to organisms, and that oxidative stress is often hypothesized to be an important factor in cytotoxicity mediated by zinc oxide nanoparticles. Nevertheless, the mechanism of toxicity of zinc oxide nanoparticles has not been completely understood. In this study, we investigated the cytotoxic effect of zinc oxide nanoparticles and the possible molecular mechanism involved in calcium homeostasis mediated by plasma membrane calcium ATPase in rat retinal ganglion cells. Real-time cell electronic sensing assay showed that zinc oxide nanoparticles could exert cytotoxic effect on rat retinal ganglion cells in a concentration-dependent manner; flow cytometric analysis indicated that zinc oxide nanoparticles could lead to cell damage by inducing the overproduction of reactive oxygen species. Furthermore, zinc oxide nanoparticles could also apparently decrease the expression level and their activity of plasma membrane calcium ATPase, which finally disrupt the intracellular calcium homeostasis and result in cell death. Taken together, zinc oxide nanoparticles could apparently decrease the plasma membrane calcium ATPase expression, inhibit their activity, cause the elevated intracellular calcium ion level and disrupt the intracellular calcium homeostasis. Further, the disrupted calcium homeostasis will trigger mitochondrial dysfunction, generate excessive reactive oxygen species, and finally initiate cell death. Thus, the disrupted calcium homeostasis is involved in the zinc oxide nanoparticle-induced rat retinal ganglion cell death. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Study of 750 J plasma coaxial accelerator

    International Nuclear Information System (INIS)

    Mehanna, E.A.; Hassouba, M.A; Abd al-halim, M.A.

    2009-01-01

    A 750 J plasma coaxial accelerator is used to produce plasma using air at 0.2 torr pressure and 8 kv charging voltage. The discharge current and voltage traces showed that the total circuit inductance was about 1750 μH. The experimental results showed that the plasma sheath reached the muzzle after 6 μs with velocity equal to 4 cm/μs, after then it decreased, while the simulation model showed that the plasma sheath reaches the muzzle with velocity of 3 cm/μs and after one microsecond it increases to reach about 4 cm/μs after 12 μs then it decreased. The plasma temperature measurements showed that the plasma sheath reached the muzzle with temperature of about 9 eV and increase to reach about 12 eV after 8.5 μs then after it decrease. The simulation model showed that the plasma temperature at the muzzle is about 10.5 eV and continue to increase to reach 17.5 eV after 12 μs then it decrease

  20. Plasma Reforming of Liquid Hydrocarbon Fuels in Non-Thermal Plasma-Liquid Systems

    Science.gov (United States)

    2010-04-30

    channel with liquid wall in the microporous media under the ultrasound cavitations has shown the following: · The action of the ultrasound field in the...microporous liquid which has a very large ratio of the plasma-liquid contact surface to the plasma volume. As is known the ultrasonic (US) cavitation is a very...2) and it ran over a flat dielectric surface of the magnetostrictive transmitter (5) which produced ultrasonic (US) cavitations , so the discharge

  1. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-01-01

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  2. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masayuki, E-mail: m.takahashi@al.t.u-tokyo.ac.jp [Department of Aeronautics and Astronautics, The University of Tokyo, Bunkyo-ku 113-8656 (Japan); Ohnishi, Naofumi [Department of Aerospace Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2016-08-14

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  3. Plasma sterol evidence for decreased absorption and increased synthesis of cholesterol in insulin resistance and obesity1234

    Science.gov (United States)

    Knopp, Robert H; Kahn, Steven E; Retzlaff, Barbara M; Fish, Brian; Ma, Lina; Ostlund, Richard E

    2011-01-01

    Background: The rise in LDL with egg feeding in lean insulin-sensitive (LIS) participants is 2- and 3-fold greater than in lean insulin-resistant (LIR) and obese insulin-resistant (OIR) participants, respectively. Objective: We determined whether differences in cholesterol absorption, synthesis, or both could be responsible for these differences by measuring plasma sterols as indexes of cholesterol absorption and endogenous synthesis. Design: Plasma sterols were measured by gas chromatography–mass spectrometry in a random subset of 34 LIS, 37 LIR, and 37 OIR participants defined by the insulin sensitivity index (SI) and by BMI criteria selected from a parent group of 197 participants. Cholestanol and plant sterols provide a measure of cholesterol absorption, and lathosterol provides a measure of cholesterol synthesis. Results: The mean (±SD) ratio of plasma total absorption biomarker sterols to cholesterol was 4.48 ± 1.74 in LIS, 3.25 ± 1.06 in LIR, and 2.82 ± 1.08 in OIR participants. After adjustment for age and sex, the relations of the absorption sterol–cholesterol ratios were as follows: LIS > OIR (P LIR (P OIR (P = 0.11). Lathosterol-cholesterol ratios were 0.71 ± 0.32 in the LIS participants, 0.95 ± 0.47 in the LIR participants, and 1.29 ± 0.55 in the OIR participants. After adjustment for age and sex, the relations of lathosterol-cholesterol ratios were as follows: LIS sterol concentrations were positively associated with SI and negatively associated with obesity, whereas lathosterol correlations were the opposite. Conclusions: Cholesterol absorption was highest in the LIS participants, whereas cholesterol synthesis was highest in the LIR and OIR participants. Therapeutic diets for hyperlipidemia should emphasize low-cholesterol diets in LIS persons and weight loss to improve SI and to decrease cholesterol overproduction in LIR and OIR persons. PMID:21940599

  4. Plasma promoted manufacturing of hydrogen and vehicular applications

    Science.gov (United States)

    Bromberg, Leslie

    2003-10-01

    Plasmas can be used for promoting reformation of fuels. Plasma-based reformers developed at MIT use a low temperature, low power, low current electrical discharge to promote partial oxidation conversion of hydrocarbon fuels into hydrogen and CO. The very fuel rich mixture is hard to ignite, and the plasmatron provides a volume-ignition. To minimize erosion and to simplify the power supply, a low current high voltage discharge is used, with wide area electrodes. The plasmatron fuel reformer operates at or slightly above atmospheric pressure. The plasma-based reformer technology provides the advantages of rapid startup and transient response; efficient conversion of the fuel to hydrogen rich gas; compact size; relaxation or elimination of reformer catalyst requirements; and capability to process difficult to reform fuels. These advantages enable use of hydrogen-manufacturing reformation technology in cars using available fuels, such as gasoline and diesel. This plasma-based reformer technology can provide substantial throughputs even without the use of a catalyst. The electrical power consumption of the device is minimized by design and operational characteristics (less than 500 W peak and 200 W average). The product from these plasma reactors is a hydrogen rich mixture that can be used for combustion enhancement and emissions aftertreatment in vehicular applications. By converting a small fraction of the fuel to hydrogen rich gas, in-cylinder combustion can be improved. With minor modification of the engine, use of hydrogen rich gas results in increased fuel efficiency and decreased emissions of smog producing gases. The status of plasma based reformer technology and its application to vehicles will be described.

  5. Hemodialysis decreases serum brain-derived neurotrophic factor concentration in humans.

    Science.gov (United States)

    Zoladz, Jerzy A; Śmigielski, Michał; Majerczak, Joanna; Nowak, Łukasz R; Zapart-Bukowska, Justyna; Smoleński, Olgierd; Kulpa, Jan; Duda, Krzysztof; Drzewińska, Joanna; Bartosz, Grzegorz

    2012-12-01

    In the present study we have evaluated the effect of a single hemodialysis session on the brain-derived neurotrophic factor levels in plasma [BDNF](pl) and in serum [BDNF](s) as well as on the plasma isoprostanes concentration [F(2) isoprostanes](pl), plasma total antioxidant capacity (TAC) and plasma cortisol levels in chronic kidney disease patients. Twenty male patients (age 69.8 ± 2.9 years (mean ± SE)) with end-stage renal disease undergoing maintenance hemodialysis on regular dialysis treatment for 15-71 months participated in this study. A single hemodialysis session, lasting 4.2 ± 0.1 h, resulted in a decrease (P = 0.014) in [BDNF](s) by ~42 % (2,574 ± 322 vs. 1,492 ± 327 pg ml(-1)). This was accompanied by an increase (P 0.05) in [BDNF](pl) and the platelets count were observed after a single dialysis session. Furthermore, basal [BDNF](s) in the chronic kidney disease patients was significantly lower (P = 0.03) when compared to the age-matched control group (n = 23). We have concluded that the observed decrease in serum BDNF level after hemodialysis accompanied by elevated [F(2)-Isoprostanes](pl) and decreased plasma TAC might be caused by enhanced oxidative stress induced by hemodialysis.

  6. Flavonol-rich dark cocoa significantly decreases plasma endothelin-1 and improves cognitive responses in urban children.

    Directory of Open Access Journals (Sweden)

    Lilian eCalderon-Garciduenas

    2013-08-01

    Full Text Available Air pollution exposures are linked to systemic inflammation, cardiovascular and respiratory morbidity and mortality, neuroinflammation and neuropathology in young urbanites. In particular, most Mexico City Metropolitan Area (MCMA children exhibit subtle cognitive deficits, and neuropathology studies show 40% of them exhibiting frontal tau hyperphosphorylation and 51% amyloid-β diffuse plaques (compared to 0% in low pollution control children. We assessed whether a short cocoa intervention can be effective in decreasing plasma endothelin 1 (ET-1 and/or inflammatory mediators in MCMA children. Thirty g of dark cocoa with 680 mg of total flavonols were given daily for 10.11± 3.4 days (range 9 to 24 days to 18 children (10.55yrs, SD =1.45; 11F/7M. Key metabolite ratios in frontal white matter and in hippocampus pre and during cocoa intervention were quantified by magnetic resonance spectroscopy. ET-1 significantly decreased after cocoa treatment (p=0.0002. Fifteen children (83% showed a marginally significant individual improvement in one or both of the applied simple short memory tasks. Endothelial dysfunction is a key feature of exposure to particulate matter and decreased endothelin-1 bioavailability is likely useful for brain function in the context of air pollution. Our findings suggest that cocoa interventions may be critical for early implementation of neuroprotection of highly exposed urban children. Multi-domain nutraceutical interventions could limit the risk for endothelial dysfunction, cerebral hypoperfusion, neuroinflammation, cognitive deficits, structural volumetric detrimental brain effects, and the early development of the neuropathological hallmarks of Alzheimer’s and Parkinson’s diseases.

  7. The Effect of Inhalation Volume and Breath-Hold Duration on the Retention of Nicotine and Solanesol in the Human Respiratory Tract and on Subsequent Plasma Nicotine Concentrations During Cigarette Smoking

    Directory of Open Access Journals (Sweden)

    Armitage AK

    2014-12-01

    Full Text Available The influence of inhalation depth and breath-hold duration on the retention of nicotine and solanesol in the human respiratory tract and on nicotine uptake was studied in ten cigarette smokers. In a first series of experiments, the subjects took seven puffs from a 10 mg ‘tar’ yield, test cigarette and a fixed volume of air (0, 75, 250, 500 or 1000 mL, as required by the protocol was inhaled after each puff in order to give a controlled ‘depth’ of inhalation. The inhalation was drawn from a bag containing the required volume of air. Following a 2 s breath-hold, subjects exhaled normally, with the first exhalation after each puff passing through a single acidified filter pad for collection of the non-retained nicotine and solanesol. Blood samples were taken before and at intervals during and after smoking for the sessions with 0, 75 and 500 mL inhalation volumes for determination of plasma nicotine and carboxyhaemoglobin levels. Another series of experiments was conducted with a fixed inhalation volume (500 mL and two further breath-hold durations (0 and 10 s in addition to 2 s from above. Nicotine and solanesol retentions were measured for each breath-hold condition. The amounts of nicotine retained within the respiratory system, expressed as a percentage of the amount taken into the mouth, were consistently higher than the corresponding values for solanesol in all five inhalation conditions (0-1000 mL, 2 s breath-hold. Nicotine retention increased from 46.5% at zero inhalation to 99.5% at 1000 mL inhalation (2 s breath-hold and from 98.0% at zero breath-hold to 99.9% at 10 s breath-hold (500 mL inhalation. Solanesol retention increased from 34.2% at zero inhalation volume to 71.9% at 1000 mL inhalation (2 s breath-hold and from 51.8% at zero breath-hold to 87.6% at 10 s breath-hold (500 mL inhalation. Plasma nicotine decreased from pre-smoking levels after zero inhalation indicating that the nicotine retained within the mouth was poorly

  8. Radiofrequency power in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This document includes the various communications that were presented at the 11th topical conference on radio frequency power in plasmas which took place in Palm Springs in May 1995. It includes current diffusion studies to assess the non-inductive current deposition profiles, experiments for plasma to reach quickly an equilibrium state, and modelling of electrons in plasma. Some comparison studies also reveal the efficiency of the Quasi-Optical Grill antenna for reactor applications. Finally, a scenario for efficient mode conversion heating in the ion cyclotron range of frequency is presented. Separate abstracts were prepared for the 6 papers in this volume. (TEC).

  9. Choline concentrations are lower in postnatal plasma of preterm infants than in cord plasma.

    Science.gov (United States)

    Bernhard, Wolfgang; Raith, Marco; Kunze, Rebecca; Koch, Vera; Heni, Martin; Maas, Christoph; Abele, Harald; Poets, Christian F; Franz, Axel R

    2015-08-01

    Choline is essential to human development, particularly of the brain in the form of phosphatidylcholine, sphingomyelin and acetylcholine, for bile and lipoprotein formation, and as a methyl group donator. Choline is actively transported into the fetus, and maternal supply correlates with cognitive outcome. Interruption of placental supply may therefore impair choline homeostasis in preterm infants. Determination of postnatal plasma concentrations of choline and its derivatives betaine and dimethylglycine (DMG) in preterm infants compared to cord and maternal blood matched for postmenstrual age (PMA). We collected plasma of very low-birth-weight infants undergoing neonatal intensive care (n = 162), cord plasma of term and preterm infants (n = 176, 24-42-week PMA), serum of parturients (n = 36), and plasma of healthy premenopausal women (n = 40). Target metabolites were analyzed with tandem mass spectrometry and reported as median (25th/75th percentiles). Cord plasma choline concentration was 41.4 (31.8-51.2) µmol/L and inversely correlated with PMA. In term but not in preterm infants, cord plasma choline was lower in girls than in boys. Prenatal glucocorticoid treatment did not affect choline levels in cord plasma, whereas betaine was decreased and DMG increased. In parturients and non-pregnant women, choline concentrations were 14.1 (10.3-16.9) and 8.8 (5.7-11.2) µmol/L, respectively, whereas betaine was lowest in parturients. After delivery, preterm infant plasma choline decreased to 20.8 (16.0-27.6) µmol/L within 48 h. Betaine and DMG correlated with plasma choline in all groups. In preterm infants, plasma choline decreases to 50 % of cord plasma concentrations, reflecting choline undernourishment and postnatal metabolic adaptation, and potentially contributing to impaired outcome.

  10. Controlled fusion and plasma physics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This document presents the several speeches that took place during the 22nd European Physical Society conference on Controlled Fusion and Plasma Physics in Bournemouth, UK, between the 2nd and 7th July 1995. The talks deal with new experiments carried out on several tokamaks, particularly Tore Supra, concerning plasma confinement and fusion. Some information on specific fusion devices or tokamak devices is provided, as well as results of experiments concerning plasma instability. Separate abstracts were prepared for all the 31 papers in this volume. (TEC).

  11. Controlled fusion and plasma physics

    International Nuclear Information System (INIS)

    1995-01-01

    This document presents the several speeches that took place during the 22nd European Physical Society conference on Controlled Fusion and Plasma Physics in Bournemouth, UK, between the 2nd and 7th July 1995. The talks deal with new experiments carried out on several tokamaks, particularly Tore Supra, concerning plasma confinement and fusion. Some information on specific fusion devices or tokamak devices is provided, as well as results of experiments concerning plasma instability. Separate abstracts were prepared for all the 31 papers in this volume. (TEC)

  12. Controlled fusion and plasma physics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    This document presents the several speeches that took place during the 22nd European Physical Society conference on Controlled Fusion and Plasma Physics in Bournemouth, UK, between the 2nd and 7th July 1995. The talks deal with new experiments carried out on several tokamaks, particularly Tore Supra, concerning plasma confinement and fusion. Some information on specific fusion devices or tokamak devices is provided, as well as results of experiments concerning plasma instability. Separate abstracts were prepared for all the 31 papers in this volume. (TEC).

  13. Distribution volumes of macromolecules in human ovarian and endometrial cancers--effects of extracellular matrix structure.

    Science.gov (United States)

    Haslene-Hox, Hanne; Oveland, Eystein; Woie, Kathrine; Salvesen, Helga B; Tenstad, Olav; Wiig, Helge

    2015-01-01

    Elements of the extracellular matrix (ECM), notably collagen and glucosaminoglycans, will restrict part of the space available for soluble macromolecules simply because the molecules cannot occupy the same space. This phenomenon may influence macromolecular drug uptake. To study the influence of steric and charge effects of the ECM on the distribution volumes of macromolecules in human healthy and malignant gynecologic tissues we used as probes 15 abundant plasma proteins quantified by high-resolution mass spectrometry. The available distribution volume (VA) of albumin was increased in ovarian carcinoma compared with healthy ovarian tissue. Furthermore, VA of plasma proteins between 40 and 190 kDa decreased with size for endometrial carcinoma and healthy ovarian tissue, but was independent of molecular weight for the ovarian carcinomas. An effect of charge on distribution volume was only found in healthy ovaries, which had lower hydration and high collagen content, indicating that a condensed interstitium increases the influence of negative charges. A number of earlier suggested biomarker candidates were detected in increased amounts in malignant tissue, e.g., stathmin and spindlin-1, showing that interstitial fluid, even when unfractionated, can be a valuable source for tissue-specific proteins. We demonstrate that the distribution of abundant plasma proteins in the interstitium can be elucidated by mass spectrometry methods and depends markedly on hydration and ECM structure. Our data can be used in modeling of drug uptake, and give indications on ECM components to be targeted to increase the uptake of macromolecular substances. Copyright © 2015 the American Physiological Society.

  14. BMT decreases HFD-induced weight gain associated with decreased preadipocyte number and insulin secretion.

    Directory of Open Access Journals (Sweden)

    Saeed Katiraei

    Full Text Available Experimental bone marrow transplantation (BMT in mice is commonly used to assess the role of immune cell-specific genes in various pathophysiological settings. The application of BMT in obesity research is hampered by the significant reduction in high-fat diet (HFD-induced obesity. We set out to characterize metabolic tissues that may be affected by the BMT procedure and impair the HFD-induced response. Male C57BL/6 mice underwent syngeneic BMT using lethal irradiation. After a recovery period of 8 weeks they were fed a low-fat diet (LFD or HFD for 16 weeks. HFD-induced obesity was reduced in mice after BMT as compared to HFD-fed control mice, characterized by both a reduced fat (-33%; p<0.01 and lean (-11%; p<0.01 mass, while food intake and energy expenditure were unaffected. As compared to control mice, BMT-treated mice had a reduced mature adipocyte volume (approx. -45%; p<0.05 and reduced numbers of preadipocytes (-38%; p<0.05 and macrophages (-62%; p<0.05 in subcutaneous, gonadal and visceral white adipose tissue. In BMT-treated mice, pancreas weight (-46%; p<0.01 was disproportionally decreased. This was associated with reduced plasma insulin (-68%; p<0.05 and C-peptide (-37%; p<0.01 levels and a delayed glucose clearance in BMT-treated mice on HFD as compared to control mice. In conclusion, the reduction in HFD-induced obesity after BMT in mice is at least partly due to alterations in the adipose tissue cell pool composition as well as to a decreased pancreatic secretion of the anabolic hormone insulin. These effects should be considered when interpreting results of experimental BMT in metabolic studies.

  15. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  16. Mechanical ventilation with high tidal volumes attenuates myocardial dysfunction by decreasing cardiac edema in a rat model of LPS-induced peritonitis

    Directory of Open Access Journals (Sweden)

    Smeding Lonneke

    2012-03-01

    Full Text Available Abstract Background Injurious mechanical ventilation (MV may augment organ injury remote from the lungs. During sepsis, myocardial dysfunction is common and increased endothelial activation and permeability can cause myocardial edema, which may, among other factors, hamper myocardial function. We investigated the effects of MV with injuriously high tidal volumes on the myocardium in an animal model of sepsis. Methods Normal rats and intraperitoneal (i.p. lipopolysaccharide (LPS-treated rats were ventilated with low (6 ml/kg and high (19 ml/kg tidal volumes (Vt under general anesthesia. Non-ventilated animals served as controls. Mean arterial pressure (MAP, central venous pressure (CVP, cardiac output (CO and pulmonary plateau pressure (Pplat were measured. Ex vivo myocardial function was measured in isolated Langendorff-perfused hearts. Cardiac expression of endothelial vascular cell adhesion molecule (VCAM-1 and edema were measured to evaluate endothelial inflammation and leakage. Results MAP decreased after LPS-treatment and Vt-dependently, both independent of each other and with interaction. MV Vt-dependently increased CVP and Pplat and decreased CO. LPS-induced peritonitis decreased myocardial function ex vivo but MV attenuated systolic dysfunction Vt-dependently. Cardiac endothelial VCAM-1 expression was increased by LPS treatment independent of MV. Cardiac edema was lowered Vt-dependently by MV, particularly after LPS, and correlated inversely with systolic myocardial function parameters ex vivo. Conclusion MV attenuated LPS-induced systolic myocardial dysfunction in a Vt-dependent manner. This was associated with a reduction in cardiac edema following a lower transmural coronary venous outflow pressure during LPS-induced coronary inflammation.

  17. Activation volume and interaction of metal particulate media

    Energy Technology Data Exchange (ETDEWEB)

    Tetsukawa, Hiroki [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)]. E-mail: tetsukaw@arc.sony.co.jp; Kondo, Hirofumi [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)

    2005-09-15

    We have investigated the activation volume (V{sub ac}) and magnetostatic interaction of metal particulate (MP) media. The activation volume of MP media decreases with the decrease of physical volume (V{sub phy}) of metal particles. The activation volume and the ratio of V{sub phy}/V{sub ac} of advanced metal particles are 6x10{sup -24}m{sup 3} and 1.5, respectively. It can be predicted that the physical volume of metal particle is about 3x10{sup -24}m{sup 3} when the physical volume is equal to the activation volume. This value is agreement with the practical lower limit of physical volume of metal particle predicted by Sharrock. The negative interaction (demagnetization effect) in MP media decreases with low saturation magnetization of the metal particles, a thin magnetic layer, a high orientation of MP media, and a low packing fraction of metal particles in the MP media. The activation volume of the MP media decreased as the negative interactions decreased. In advanced MP media with low M{sub r}.t (M{sub r}=remanent magnetization and t=thickness), the influence of interaction on the activation volume is reduced.

  18. Activation volume and interaction of metal particulate media

    International Nuclear Information System (INIS)

    Tetsukawa, Hiroki; Kondo, Hirofumi

    2005-01-01

    We have investigated the activation volume (V ac ) and magnetostatic interaction of metal particulate (MP) media. The activation volume of MP media decreases with the decrease of physical volume (V phy ) of metal particles. The activation volume and the ratio of V phy /V ac of advanced metal particles are 6x10 -24 m 3 and 1.5, respectively. It can be predicted that the physical volume of metal particle is about 3x10 -24 m 3 when the physical volume is equal to the activation volume. This value is agreement with the practical lower limit of physical volume of metal particle predicted by Sharrock. The negative interaction (demagnetization effect) in MP media decreases with low saturation magnetization of the metal particles, a thin magnetic layer, a high orientation of MP media, and a low packing fraction of metal particles in the MP media. The activation volume of the MP media decreased as the negative interactions decreased. In advanced MP media with low M r .t (M r =remanent magnetization and t=thickness), the influence of interaction on the activation volume is reduced

  19. Exhaustive and stable electromembrane extraction of acidic drugs from human plasma

    DEFF Research Database (Denmark)

    Huang, Chuixiu; Gjelstad, Astrid; Seip, Knut Fredrik

    2015-01-01

    The first part of the current work systematically described the screening of different types of organic solvents as the supported liquid membrane (SLM) for electromembrane extraction (EME) of acidic drugs, including different alcohols, ketones, and ethers. Seven acidic drugs with a wide logP rang......). With this SLM, exhaustive EME was performed from diluted human plasma, and the recoveries of five out of seven analytes were over 91% after 10min EME. This approach was evaluated using HPLC-UV, and the evaluation data were found to be satisfactory...... to increasing viscosity and decreasing α and π* values. The system-current during EME was found to be dependent on the type and the volume of the SLM. In contact with human plasma, an SLM of pure 1-heptanol was unstable, and to improve stability, 1-heptanol was mixed with 2-nitrophenyl octyl ether (NPOE...

  20. TMX-U [Tandem Mirror Experiment-Upgrade]: Final report, Volume 1

    International Nuclear Information System (INIS)

    Porter, G.D.

    1988-01-01

    This paper discusses the plasma control and the physics accomplishments of the Tandem Mirror Experiment-Upgrade. This particular volume discusses potential measurements, plasma confinement, and hot electron and ion physics. 230 refs

  1. Aldosterone and mortality in hemodialysis patients: role of volume overload.

    Science.gov (United States)

    Hung, Szu-Chun; Lin, Yao-Ping; Huang, Hsin-Lei; Pu, Hsiao-Fung; Tarng, Der-Cherng

    2013-01-01

    Elevated aldosterone is associated with increased mortality in the general population. In patients on dialysis, however, the association is reversed. This paradox may be explained by volume overload, which is associated with lower aldosterone and higher mortality. We evaluated the relationship between aldosterone and outcomes in a prospective cohort of 328 hemodialysis patients stratified by the presence or absence of volume overload (defined as extracellular water/total body water >48%, as measured with bioimpedance). Baseline plasma aldosterone was measured before dialysis and categorized as low (280 pg/mL). Overall, 36% (n = 119) of the hemodialysis patients had evidence of volume overload. Baseline aldosterone was significantly lower in the presence of volume overload than in its absence. During a median follow-up of 54 months, 83 deaths and 70 cardiovascular events occurred. Cox multivariate analysis showed that by using the low aldosterone as the reference, high aldosterone was inversely associated with decreased hazard ratios for mortality (0.49; 95% confidence interval, 0.25-0.76) and first cardiovascular event (0.70; 95% confidence interval, 0.33-0.78) in the presence of volume overload. In contrast, high aldosterone was associated with an increased risk for mortality (1.97; 95% confidence interval, 1.69-3.75) and first cardiovascular event (2.01; 95% confidence interval, 1.28-4.15) in the absence of volume overload. The inverse association of aldosterone with adverse outcomes in hemodialysis patients is due to the confounding effect of volume overload. These findings support treatment of hyperaldosteronemia in hemodialysis patients who have achieved strict volume control.

  2. High-beta plasma effects in a low-pressure helicon plasma

    International Nuclear Information System (INIS)

    Corr, C. S.; Boswell, R. W.

    2007-01-01

    In this work, high-beta plasma effects are investigated in a low-pressure helicon plasma source attached to a large volume diffusion chamber. When operating above an input power of 900 W and a magnetic field of 30 G a narrow column of bright blue light (due to Ar II radiation) is observed along the axis of the diffusion chamber. With this blue mode, the plasma density is axially very uniform in the diffusion chamber; however, the radial profiles are not, suggesting that a large diamagnetic current might be induced. The diamagnetic behavior of the plasma has been investigated by measuring the temporal evolution of the magnetic field (B z ) and the plasma kinetic pressure when operating in a pulsed discharge mode. It is found that although the electron pressure can exceed the magnetic field pressure by a factor of 2, a complete expulsion of the magnetic field from the plasma interior is not observed. In fact, under our operating conditions with magnetized ions, the maximum diamagnetism observed is ∼2%. It is observed that the magnetic field displays the strongest change at the plasma centre, which corresponds to the maximum in the plasma kinetic pressure. These results suggest that the magnetic field diffuses into the plasma sufficiently quickly that on a long time scale only a slight perturbation of the magnetic field is ever observed

  3. Air spark-like plasma source for antimicrobial NOx generation

    International Nuclear Information System (INIS)

    Pavlovich, M J; Galleher, C; Curtis, B; Clark, D S; Graves, D B; Ono, T; Machala, Z

    2014-01-01

    We demonstrate and analyse the generation of nitrogen oxides and their antimicrobial efficacy using atmospheric air spark-like plasmas. Spark-like discharges in air in a 1 L confined volume are shown to generate NO x at an initial rate of about 1.5  ×  10 16 NO x molecules/J dissipated in the plasma. Such a discharge operating in this confined volume generates on the order of 6000 ppm NO x in 10 min. Around 90% of the NO x is in the form of NO 2 after several minutes of operation in the confined volume, suggesting that NO 2 is the dominant antimicrobial component. The strong antimicrobial action of the NO x mixture after several minutes of plasma operation is demonstrated by measuring rates of E. coli disinfection on surfaces and in water exposed to the NO x mixture. Some possible applications of plasma generation of NO x (perhaps followed by dissolution in water) include disinfection of surfaces, skin or wound antisepsis, and sterilization of medical instruments at or near room temperature. (paper)

  4. THERMODYNAMIC REASONS OF AGGLOMERATION OF DUST PARTICLES IN THE THERMAL DUSTY PLASMA

    Directory of Open Access Journals (Sweden)

    V.I.Vishnyakov

    2003-01-01

    Full Text Available The thermodynamic equilibrium of thermal dusty plasmas consisting of ionized gas (plasma and solid particles (dust grains, which interact with each other, is studied. The tendency of grains in dusty plasmas to agglomerate corresponds to the tendency of dusty plasmas to balanced states. When grains agglomerate, electrical perturbations generated by each grain concentrate inside the agglomerate. The plasma is perturbed only by the agglomerate's exterior surface. The greater number of possible states for electrons and ions in plasma depends on the volume of perturbation of grains. The fewer are the perturbations the greater is the amount of possible states for electrons and ions in plasma. If the grains collected from a distance smaller than 8 Debye lengths, the total volume of perturbations is minimized; the free energy of the plasma is also minimized.

  5. TMX-U [Tandem Mirror Experiment-Upgrade]: Final report, Volume 2

    International Nuclear Information System (INIS)

    Porter, G.D.

    1988-01-01

    This paper discusses the plasma control and the physics accomplishments of the Tandem Mirror Experiment-Upgrade. This particular volume discusses fueling, ion heating, Fokker-Planck modeling, plasma stability and technical development. 270 refs

  6. Effect of High-Volume Injection, Platelet-Rich Plasma, and Sham Treatment in Chronic Midportion Achilles Tendinopathy

    DEFF Research Database (Denmark)

    Boesen, Anders Ploug; Hansen, Rudi; Boesen, Morten Ilum

    2017-01-01

    with eccentric training in chronic AT seems more effective in reducing pain, improving activity level, and reducing tendon thickness and intratendinous vascularity than eccentric training alone. HVI may be more effective in improving outcomes of chronic AT than PRP in the short term. Registration: NCT02417987......BACKGROUND: Injection therapies are often considered alongside exercise for chronic midportion Achilles tendinopathy (AT), although evidence of their efficacy is sparse. PURPOSE: To determine whether eccentric training in combination with high-volume injection (HVI) or platelet-rich plasma (PRP......) injections improves outcomes in AT. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A total of 60 men (age, 18-59 years) with chronic (>3 months) AT were included and followed for 6 months (n = 57). All participants performed eccentric training combined with either (1) one HVI...

  7. The plasma-wall interaction region: a key low temperature plasma for controlled fusion

    International Nuclear Information System (INIS)

    Counsell, G F

    2002-01-01

    The plasma-wall interaction region of a fusion device provides the interface between the hot core plasma and the material surfaces. To obtain acceptably low levels of erosion from these surfaces requires most of the power leaving the core to be radiated. This is accomplished in existing devices by encouraging plasma detachment, in which the hot plasma arriving in the region is cooled by volume recombination and ion-neutral momentum transfer with a dense population of neutrals recycled from the surface. The result is a low temperature (1 eV e e >10 19 m -3 ) but weakly ionized (n 0 >10 20 m -3 , n e /n 0 <0.1) plasma found nowhere else in the fusion environment. This plasma provides many of the conditions found in industrial plasmas exploiting plasma chemistry and the presence of carbon in the region (in the form of carbon-fibre composite used in the plasma facing materials) can result in the formation of deposited hydrocarbon films. The plasma-wall interaction region is therefore among the most difficult in fusion to model, requiring an understanding of atomic, molecular and surface physics issues

  8. Comparative analysis of turbulent effects on thermal plasma characteristics inside the plasma torches with rod- and well-type cathodes

    International Nuclear Information System (INIS)

    Hur, Min; Hong, Sang Hee

    2002-01-01

    The thermal plasma characteristics inside the two non-transferred plasma torches with rod-type cathode (RTC) and well-type cathode (WTC) are analysed in conjunction with turbulent effects on them in the atmospheric-pressure conditions. A control volume method and a modified semi-implicit pressure linked equations revised algorithm are used for solving the governing equations, i.e. conservation equations of mass, momentum, and energy together with a current continuity equation for arc discharge. A cold flow analysis is introduced to find the cathode spot position in the WTC torch, and both the laminar and turbulent models are employed to gain a physical insight into the turbulent effects on the thermal plasma characteristics produced inside the two torches. The numerical analysis for an RTC torch shows that slightly different values of plasma temperature and velocity between the laminar and turbulent calculations occur and the radial temperature profiles are constricted at the axis with increasing the gas flow rate, and that the large turbulent viscosities appear mostly near the anode wall. These calculated results indicate that the turbulent effects on the thermal plasma characteristics are very weak in the whole discharge region inside the RTC torch. On the other hand, the calculated results of the two numerical simulations for a WTC torch present that the significantly different values of plasma characteristics between the two models appear in the whole torch region and the plasma temperatures decrease with increasing the gas flow rate because the relatively strong turbulent effects are prevailing in the entire interior region of the WTC torch. From the comparisons of plasma net powers calculated and measured in this work, the turbulent modelling turns out to provide the more accurately calculated results close to the measured ones compared with the laminar one, especially for the torch with WTC. This is because the turbulent effects are considerably strong in

  9. Regulatory volume decrease in isolated nematocytes is affected by crude venom from the jellyfish Pelagia noctiluca

    Directory of Open Access Journals (Sweden)

    Rossana Morabito

    2014-11-01

    Full Text Available Crude venom from nematocysts of the Scyphozoan Pelagia noctiluca possesses hemolytic and cytotoxic power on cultured cells and elicits local and systemic inflammation reactions in vivo. The ability of regulating their volume after exposure to an anisosmotic solution is a fundamental feature common to cells from vertebrates and invertebrates, including Cnidarians. The aim of the present work i s to assay whether crude venom from Pelagia noctiluca may affect the regulatory volume decrease (RVD of nematocytes isolated from the Anthozoan Aiptasia mutabilis, here employed as a cell model. For this purpose, nematocytes were isolated by 605 mM NaSCN plus 0.01 mM Ca2+ application on acontia of Aiptasia mutabilis, while crude venom was obtained by sonication of a population of, respectively, 10, 25 and 50 nematocysts/µL (n/µL. Isolated nematocytes were pre-treated for 30 min with crude venom, submitted to hypotonic stress and their osmotic response and RVD were measured optically. Our results show that, after exposure to crude venom, nematocytes were morphologically intact, as shown by the Trypan blue exclusion test, but did not exhibit RVD. This effect was dose-dependent and reversed by the ionopho re gramicidin. The last observation suggests an inhibitory effect of venom on cell membrane ion transport mechanisms involved in RVD. Further studies are needed to verify this hypothesis and ascertain if a similar effect could be observed in human cells.

  10. Plasma renin activity, aldosterone and catecholamine levels when swimming and running.

    Science.gov (United States)

    Guezennec, C Y; Defer, G; Cazorla, G; Sabathier, C; Lhoste, F

    1986-01-01

    The purpose of this study was to determine the response of plasma renin activity (PRA), plasma aldosterone concentration (PAC) and catecholamines to two graded exercises differing by posture. Seven male subjects (19-25 years) performed successively a running rest on a treadmill and a swimming test in a 50-m swimming pool. Each exercise was increased in severity in 5-min steps with intervals of 1 min. Oxygen consumption, heart rate and blood lactate, measured every 5 min, showed a similar progression in energy expenditure until exhaustion, but there was a shorter time to exhaustion in the last step of the running test. PRA, PAC and catecholamines were increased after both types of exercise. The PRA increase was higher after the running test (20.9 ng AngI X ml-1 X h-1) than after swimming (8.66 ng AngI X ml-1 X h-1). The PAC increase was slightly greater after running (123 pg X ml-1) than swimming (102 pg X ml-1), buth the difference was not significant. Plasma catecholamine was higher after the swimming test. These results suggest that the volume shift induced by the supine position and water pressure during swimming decreased the PRA response. The association after swimming compared to running of a decreased PRA and an enhanced catecholamine response rule out a strict dependence of renin release under the effect of plasma catecholamines and is evidence of the major role of neural pathways for renin secretion during physical exercise.

  11. Long-term exposure to electromagnetic radiation from mobile phones and Wi-Fi devices decreases plasma prolactin, progesterone, and estrogen levels but increases uterine oxidative stress in pregnant rats and their offspring.

    Science.gov (United States)

    Yüksel, Murat; Nazıroğlu, Mustafa; Özkaya, Mehmet Okan

    2016-05-01

    We investigated the effects of mobile phone (900 and 1800 MHz)- and Wi-Fi (2450 MHz)-induced electromagnetic radiation (EMR) exposure on uterine oxidative stress and plasma hormone levels in pregnant rats and their offspring. Thirty-two rats and their forty newborn offspring were divided into the following four groups according to the type of EMR exposure they were subjected to: the control, 900, 1800, and 2450 MHz groups. Each experimental group was exposed to EMR for 60 min/day during the pregnancy and growth periods. The pregnant rats were allowed to stand for four generations (total 52 weeks) before, plasma and uterine samples were obtained. During the 4th, 5th, and 6th weeks of the experiment, plasma and uterine samples were also obtained from the developing rats. Although uterine lipid peroxidation increased in the EMR groups, uterine glutathione peroxidase activity (4th and 5th weeks) and plasma prolactin levels (6th week) in developing rats decreased in these groups. In the maternal rats, the plasma prolactin, estrogen, and progesterone levels decreased in the EMR groups, while the plasma total oxidant status, and body temperatures increased. There were no changes in the levels of reduced glutathione, total antioxidants, or vitamins A, C, and E in the uterine and plasma samples of maternal rats. In conclusion, although EMR exposure decreased the prolactin, estrogen, and progesterone levels in the plasma of maternal rats and their offspring, EMR-induced oxidative stress in the uteri of maternal rats increased during the development of offspring. Mobile phone- and Wi-Fi-induced EMR may be one cause of increased oxidative uterine injury in growing rats and decreased hormone levels in maternal rats. TRPV1 cation channels are the possible molecular pathways responsible for changes in the hormone, oxidative stress, and body temperature levels in the uterus of maternal rats following a year-long exposure to electromagnetic radiation exposure from mobile phones and

  12. Molecular Diagnostics of Fusion and Laboratory Plasmas

    Science.gov (United States)

    Fantz, U.

    2005-05-01

    The presence of molecules in the cold scrape-off layer of fusion experiments and industrial plasmas requires an understanding of the molecular dynamics in these low temperature plasmas. Suitable diagnostic methods can provide an insight in molecular processes in the plasma volume as well as for plasma surface interactions. A very simple but powerful technique is the molecular emission spectroscopy. Spectra are obtained easily, whereas interpretation might be very complex and relies on the availability of atomic and molecular data. Examples are given for hydrogen plasmas and plasmas with hydrocarbons which both are of importance in industrial applications as well as in fusion experiments.

  13. Molecular Diagnostics of Fusion and Laboratory Plasmas

    International Nuclear Information System (INIS)

    Fantz, U.

    2005-01-01

    The presence of molecules in the cold scrape-off layer of fusion experiments and industrial plasmas requires an understanding of the molecular dynamics in these low temperature plasmas. Suitable diagnostic methods can provide an insight in molecular processes in the plasma volume as well as for plasma surface interactions. A very simple but powerful technique is the molecular emission spectroscopy. Spectra are obtained easily, whereas interpretation might be very complex and relies on the availability of atomic and molecular data. Examples are given for hydrogen plasmas and plasmas with hydrocarbons which both are of importance in industrial applications as well as in fusion experiments

  14. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  15. [Evaluation of tidal volume delivered by ventilators during volume-controlled ventilation].

    Science.gov (United States)

    Zhou, Juan; Yan, Yong; Cao, Desen

    2014-12-01

    To study the ways which ensure the delivery of enough tidal volume to patients under various conditions close to the demand of the physician. The volume control ventilation model was chosen, and the simulation lung type was active servo lung ASL 5000 or Michigan lung 1601. The air resistance, air compliance and lung type in simulation lungs were set. The tidal volume was obtained from flow analyzer PF 300. At the same tidal volume, the displaying values of tidal volume of E5, Servo i, Evital 4, and Evital XL ventilators with different lung types of patient, compliance of gas piping, leakage, gas types, etc. were evaluated. With the same setting tidal volume of a same ventilator, the tidal volume delivered to patients was different with different lung types of patient, compliance of gas piping, leakage, gas types, etc. Reducing compliance and increasing resistance of the patient lungs caused high peak airway pressure, the tidal volume was lost in gas piping, and the tidal volume be delivered to the patient lungs was decreased. If the ventilator did not compensate to leakage, the tidal volume delivered to the patient lungs was decreased. When the setting gas type of ventilator did not coincide with that applying to the patient, the tidal volume be delivered to the patient lungs might be different with the setting tidal volume of ventilator. To ensure the delivery of enough tidal volume to patients close to the demand of the physician, containable factors such as the compliance of gas piping, leakage, and gas types should be controlled.

  16. Membrane-based, sedimentation-assisted plasma separator for point-of-care applications.

    Science.gov (United States)

    Liu, Changchun; Mauk, Michael; Gross, Robert; Bushman, Frederic D; Edelstein, Paul H; Collman, Ronald G; Bau, Haim H

    2013-11-05

    Often, high-sensitivity, point-of-care (POC) clinical tests, such as HIV viral load, require large volumes of plasma. Although centrifuges are ubiquitously used in clinical laboratories to separate plasma from whole blood, centrifugation is generally inappropriate for on-site testing. Suitable alternatives are not readily available to separate the relatively large volumes of plasma from milliliters of blood that may be needed to meet stringent limit-of-detection specifications for low-abundance target molecules. We report on a simple-to-use, low-cost, pump-free, membrane-based, sedimentation-assisted plasma separator capable of separating a relatively large volume of plasma from undiluted whole blood within minutes. This plasma separator consists of an asymmetric, porous, polysulfone membrane housed in a disposable chamber. The separation process takes advantage of both gravitational sedimentation of blood cells and size exclusion-based filtration. The plasma separator demonstrated a "blood in-plasma out" capability, consistently extracting 275 ± 33.5 μL of plasma from 1.8 mL of undiluted whole blood within less than 7 min. The device was used to separate plasma laden with HIV viruses from HIV virus-spiked whole blood with recovery efficiencies of 95.5% ± 3.5%, 88.0% ± 9.5%, and 81.5% ± 12.1% for viral loads of 35,000, 3500, and 350 copies/mL, respectively. The separation process is self-terminating to prevent excessive hemolysis. The HIV-laden plasma was then injected into our custom-made microfluidic chip for nucleic acid testing and was successfully subjected to reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP), demonstrating that the plasma is sufficiently pure to support high-efficiency nucleic acid amplification.

  17. Plasmas applied atomic collision physics, v.2

    CERN Document Server

    Barnett, C F

    1984-01-01

    Applied Atomic Collision Physics, Volume 2: Plasmas covers topics on magnetically confined plasmas. The book starts by providing the history of fusion research and describing the various approaches in both magnetically and inertially confined plasmas. The text then gives a general discussion of the basic concepts and properties in confinement and heating of a plasma. The theory of atomic collisions that result in excited quantum states, particularly highly ionized impurity atoms; and diverse diagnostic topics such as emission spectra, laser scattering, electron cyclotron emission, particle bea

  18. Quark gluon plasma

    CERN Document Server

    Nayak, Tapan; Sarkar, Sourav

    2014-01-01

    At extremely high temperatures and densities, protons and neutrons may dissolve into a "soup" of quarks and gluons, called the Quark-Gluon Plasma (QGP). For a few microseconds, shortly after the Big Bang, the Universe was filled with the QGP matter. The search and study of Quark-Gluon Plasma (QGP) is one of the most fundamental research topics of our times. The QGP matter has been probed by colliding heavy ions at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, New York and the Large Hadron Collider at CERN, Geneva. By colliding heavy-ions at a speed close to that of light, scientists aim to obtain - albeit over a tiny volume of the size of a nucleus and for an infinitesimally short instant - a QGP state. This QGP state can be observed by dedicated experiments, as it reverts to hadronic matter through expansion and cooling. This volume presents some of the current theoretical and experimental understandings in the field of QGP.

  19. Interaction of nanosecond ultraviolet laser pulses with reactive dusty plasma

    International Nuclear Information System (INIS)

    Wetering, F. M. J. H. van de; Oosterbeek, W.; Beckers, J.; Nijdam, S.; Gibert, T.; Mikikian, M.; Rabat, H.; Kovačević, E.; Berndt, J.

    2016-01-01

    Even though UV laser pulses that irradiate a gas discharge are small compared to the plasma volume (≲3%) and plasma-on time (≲6 × 10 −6 %), they are found to dramatically change the discharge characteristics on a global scale. The reactive argon–acetylene plasma allows the growth of nanoparticles with diameters up to 1 μm, which are formed inside the discharge volume due to spontaneous polymerization reactions. It is found that the laser pulses predominantly accelerate and enhance the coagulation phase and are able to suppress the formation of a dust void.

  20. Specificity of direct radioimmunoassays of unconjugated estrone and estradiol-17β in plasma

    International Nuclear Information System (INIS)

    Grenier, J.; Strauss, N.; Scholler, R.

    1977-01-01

    Procedures for radioimmunoassay of estrone and estradiol-17β in plasma, which do not include a chromatographic step or even plasma extractions are now described in the literature and are recommended in most commercially available kits. Besides leading often to a systematic overestimation of estrogen concentrations, such techniques are liable to give results which are volume-dependent. Since this defect might be due to the type of antiserum used or the mode of separation of free and antibodybound steroid, the influence of plasma volume was studied, either with a modification of Castanier and Scholler method - i.e. suppression of Sephadex LH-20 chromatography -, using antisera of different types, or with estrogen kits. The separation step was a toluene extraction in the modified method, and dextran-coated charcoal or polyethylene glycol in procedures of commercial kits. The volume effect was always found, with varying degrees, according to the plasma sample. It was most marked in plasmas of hyperlipidemic patients. The addition of fatty acids, at an upper physiological dose, led to a modification of the standard curve, with over-estimation at low levels and under-estimation at high levels, resulting in calculated estrogen concentrations depending on volume. The use of highly specific antiserum as determined by cross-reaction studies with authentic steroids does not necessarily imply the possibility of performing direct assays which ought to pass the test of plasma volume effect before being accepted. (orig.) [de

  1. Propagation of high frequency electrostatic surface waves along the planar interface between plasma and dusty plasma

    Science.gov (United States)

    Mishra, Rinku; Dey, M.

    2018-04-01

    An analytical model is developed that explains the propagation of a high frequency electrostatic surface wave along the interface of a plasma system where semi-infinite electron-ion plasma is interfaced with semi-infinite dusty plasma. The model emphasizes that the source of such high frequency waves is inherent in the presence of ion acoustic and dust ion acoustic/dust acoustic volume waves in electron-ion plasma and dusty plasma region. Wave dispersion relation is obtained for two distinct cases and the role of plasma parameters on wave dispersion is analyzed in short and long wavelength limits. The normalized surface wave frequency is seen to grow linearly for lower wave number but becomes constant for higher wave numbers in both the cases. It is observed that the normalized frequency depends on ion plasma frequencies when dust oscillation frequency is neglected.

  2. Reduced and high molecular weight barley beta-glucans decrease plasma total and non-HDL-cholesterol in hypercholesterolemic Syrian golden hamsters.

    Science.gov (United States)

    Wilson, Thomas A; Nicolosi, Robert J; Delaney, Bryan; Chadwell, Kim; Moolchandani, Vikas; Kotyla, Timothy; Ponduru, Sridevi; Zheng, Guo-Hua; Hess, Richard; Knutson, Nathan; Curry, Leslie; Kolberg, Lore; Goulson, Melanie; Ostergren, Karen

    2004-10-01

    Consumption of concentrated barley beta-glucan lowers plasma cholesterol because of its soluble dietary fiber nature. The role of molecular weight (MW) in lowering serum cholesterol is not well established. Prior studies showed that enzymatic degradation of beta-glucan eliminates the cholesterol-lowering activity; however, these studies did not evaluate the MW of the beta-glucan. The current study was conducted to evaluate whether barley beta-glucan concentrates, partially hydrolyzed to reduce MW, possess cholesterol-lowering and antiatherogenic activities. The reduced MW fraction was compared with a high MW beta-glucan concentrate from the same barley flour. Concentrated beta-glucan preparations were evaluated in Syrian Golden F(1)B hamsters fed a hypercholesterolemic diet (HCD) with cholesterol, hydrogenated coconut oil, and cellulose. After 2 wk, hamsters were fed HCD or diets that contained high or reduced MW beta-glucan at a concentration of 8 g/100 g at the expense of cellulose. Decreases in plasma total cholesterol (TC) and non-HDL-cholesterol (non-HDL-C) concentrations occurred in the hamsters fed reduced MW and high MW beta-glucan diets. Plasma HDL-C concentrations did not differ. HCD-fed hamsters had higher plasma triglyceride concentrations. Liver TC, free cholesterol, and cholesterol ester concentrations did not differ. Aortic cholesterol ester concentrations were lower in the reduced MW beta-glucan-fed hamsters. Consumption of either high or reduced MW beta-glucan increased concentrations of fecal total neutral sterols and coprostanol, a cholesterol derivative. Fecal excretion of cholesterol was greater than in HCD-fed hamsters only in those fed the reduced MW beta-glucan. Study results demonstrate that the cholesterol-lowering activity of barley beta-glucan may occur at both lower and higher MW.

  3. Changes in the electro-physical properties of MCT epitaxial films affected by a plasma volume discharge induced by an avalanche beam in atmospheric-pressure air

    Science.gov (United States)

    Grigoryev, D. V.; Voitsekhovskii, A. V.; Lozovoy, K. A.; Tarasenko, V. F.; Shulepov, M. A.

    2015-11-01

    In this paper the influence of the plasma volume discharge of nanosecond duration formed in a non-uniform electric field at atmospheric pressure on samples of epitaxial films HgCdTe (MCT) films are discussed. The experimental data show that the action of pulses of nanosecond volume discharge in air at atmospheric pressure leads to changes in the electrophysical properties of MCT epitaxial films due to formation of a near-surface high- conductivity layer of the n-type conduction. The preliminary results show that it is possible to use such actions in the development of technologies for the controlled change of the properties of MCT.

  4. The 26th IEEE international conference on plasma science

    International Nuclear Information System (INIS)

    1999-01-01

    Some of the sessions covered by this conference are: Basic Processes in Fully and Partially Ionized Plasmas; Slow Wave Devices; Laser-Produced Plasma; Non-Equilibrium Plasma Processing; Space Plasmas and Partially Ionized Gases; Microwave Plasmas; Inertial Confinement Fusion; Plasma Diagnostics; Computational Plasma Physics; Microwave Systems; Laser Produced Plasmas and Dense Plasma Focus; Intense Electron and Ion Beams; Fast Wave Devices; Spherical Configurations and Ball Lightning; Thermal Plasma Chemistry and Processing and Environmental Issues in Plasma Science; Plasma, Ion, and Electron Sources; Fast Wave Devices and Intense Beams; Fast Z-pinches and X-ray Lasers; Plasma Opening Switches; Plasma for Lighting; Intense Beams; Vacuum Microwaves; Magnetic Fusion Energy; and Plasma Thrusters and Arcs. Separate abstracts were prepared for some of the papers in this volume

  5. Development and Use of the Dual-Mode Plasma Torch

    International Nuclear Information System (INIS)

    Womack, R.; Shuey, M.

    2002-01-01

    After several years of development, a commercially available high-temperature treatment system has been developed and installed that treats heterogeneous low-level radioactive waste. High temperature plasma processing, unique torch design and operating features make it feasible to achieve a volume reduced, permanent, high integrity waste form while eliminating the personnel exposure and costs associated with conventional sorting, characterizing and handling. Plasma technology can also be used to treat previous conditioned waste packages that no longer meet the current acceptance criteria for final disposal. Plasma treatment can result, in many cases, in a substantial volume reduction, which lowers the final disposal costs. This paper covers the recently patented dual mode plasma torch design(1), the lessons learned that fostered its development and the advantages it brings to radioactive waste processing. This paper also provides current full scale Plasma Arc Centrifugal Treatment (PACT) project status and how the dual mode torch is being used in the PACT system

  6. Bakery products enriched with phytosterol esters, alpha-tocopherol and beta-carotene decrease plasma LDL-cholesterol and maintain plasma beta-carotene concentrations in normocholesterolemic men and women.

    Science.gov (United States)

    Quílez, Joan; Rafecas, Magda; Brufau, Gemma; García-Lorda, Pilar; Megías, Isabel; Bulló, Mònica; Ruiz, Joan A; Salas-Salvadó, Jordi

    2003-10-01

    The hypocholesterolemic effects of phytosterols have not been evaluated in bakery products, and the addition of liposoluble antioxidants to the carrier has never been tested. We investigated the effects of consuming croissants and magdalenas (Spanish muffins) enriched with sterol esters, alpha-tocopherol and beta-carotene on plasma lipid and fat-soluble antioxidant concentrations in normocholesterolemic, habitual consumers of bakery products following their usual diet and lifestyle. Using a randomized, double-blind, placebo-controlled design, the control (C) group (n = 29) received two pieces daily (standard croissant and muffin) and the sterol ester (SE) group (n = 28), the same products with sterol esters added (3.2 g/d) for 8 wk. Total and LDL cholesterol (LDL-C) decreased in the SE group by 0.24 mmol/L (P bakery products are excellent carriers for phytosterols, and their consumption is associated with a decrease in total and LDL-C concentrations, with no changes in alpha-tocopherol and beta-carotene. The ability of bakery products to include sufficient quantities of beta-carotene to compensate for a potential deficiency, and the fact that their efficacy was not associated with the time of day at which they were consumed, are interesting findings.

  7. EDITORIAL: Plasma jets and plasma bullets Plasma jets and plasma bullets

    Science.gov (United States)

    Kong, M. G.; Ganguly, B. N.; Hicks, R. F.

    2012-06-01

    technological solution in the early to late 1990s of confining atmospheric plasmas in a small volume of plasma generation (i.e. with a small volume-to-surface ratio) and then extending it towards a downstream sample [7]-[9]. These are among the first low-temperature atmospheric plasmas aimed particularly at the exploitation of their ability to invoke the active and rich reactive chemistry close to ambient temperature. The main applications of these early devices are precision surface modification of low-temperature dielectric materials, for example thin film deposition and etching [7]-[9]. Variations of the early plasma jets include atmospheric plasma sheet jets [10] for the treatment of largely planar objects (e.g. polymeric sheets) as well as large arrays of many plasma jets for the treatment of complex-structured objects (e.g. surgical tools and open human wounds) [11]. As a material processing technology, the sub-100oC atmospheric-pressure plasma jet has benefited over the years from many innovations. Whilst a detailed account and analysis of these is clearly outside the scope of this Editorial, it is worth stating that there are different avenues with which to maintain a moderate electron density at the plasma core so as to keep the gas temperature at the sample point below a ceiling level. Most of the early studies employed excitation at radio frequencies above 10 MHz, at which electrons are largely confined in the plasma generation region, and this limits the current flow to and gas heating in the plume region of the plasma jet. Other techniques of current limitation have since been shown to be effective, including the use of dielectric barriers across a very large frequency range of 1 kHz--50 MHz, sub-microsecond pulses sustained at kHz frequencies, pulse-modulated radio frequencies and dual-frequency excitation [12]-[15]. These and other techniques have considerably advanced the atmospheric-pressure plasma jet technology. The period of some 15 years since the above

  8. Slow convection of a magnetized plasma and the earth plasma sheet

    International Nuclear Information System (INIS)

    Hruska, A.

    1980-01-01

    Stationary convection of an isotropic, infinitely conducting plasma in a magnetic field with non-trivial geometry is discussed under the assumption that the inertial term in the equation of motion may be ignored. The energy gained or lost by a volume element of plasma per unit time does not vary along the field-lines. Simple relations between the components of the current density, depending on the field-line geometry, exist. Similar relations hold for the components of the plasma velocity. The theoretical analysis is applied to the geomagnetically-quiet plasma sheet and a qualitative physical picture of the sheet is suggested. The observed structure of the sheet is compatible with Axford-Hines type of convection perhaps combined with a low-speed flow from a distant neutral point. The magnetic-field-aligned currents are driven by the deformations of the closed field-lines which are enforced by the solar wind. (orig.)

  9. Fine structures and magnetic properties of FeCo granular thin films with plasma polymerized (C4F8) n matrix

    International Nuclear Information System (INIS)

    Kakizaki, K.; Yasoshima, S.; Choi, K.-K.; Kamishima, K.; Hiratsuka, N.

    2007-01-01

    In this paper a method for polymerization of fluorocarbon gas in argon plasma to obtain a novel granular structure was reported. We prepared granular films where FeCo fine particles were distributed in plasma-polymerized fluorocarbon matrix by a facing-targets RF magnetron sputtering method, and investigated the correlation between their structures and magnetic properties. The magnetization of the films prepared with the partial pressure of fluorocarbon gas between 0 and 1.0 mTorr decreased linearly, because the FeCo content in a unit volume of a film decreased when a polymerized material was used as the matrix. However, the coercivity of the films decreased drastically with increasing the partial pressure of fluorocarbon gas above 0.4 mTorr. This is because the magnetic anisotropy of FeCo particles is decreased by the decrease of grain size. It was confirmed by a TEM observation that the FeCo-(C 4 F 8 ) n films had the granular structure which was constituted by the very fine FeCo particles and the plasma-polymerized fluorocarbon matrix. For the film deposited at the partial pressure of fluorocarbon gas of 0.4 mTorr, the size of FeCo magnetic particles is about 20 nm. On the other hand, the size of FeCo particles is decreased to about 8 nm when the film deposited at the partial pressure of fluorocarbon gas of 0.8 mTorr and its distribution is small

  10. Effects of experimentally increased protein supply to postpartum dairy cows on plasma protein synthesis, rumen tissue proliferation, and immune homeostasis

    DEFF Research Database (Denmark)

    Larsen, Mogens; Røntved, Christine Maria; Theil, Peter Kappel

    2017-01-01

    The effect of experimentally increasing the postpartum protein supply on plasma protein synthesis, rumen tissue proliferation, and immune homeostasis was studied using 8 periparturient Holstein cows in a complete randomized design. At calving, cows were assigned to abomasal infusion of water (CTRL......) or casein (CAS) in addition to a lactation diet. Casein infusion was gradually decreased from 696 ± 1 g/d at +2 d relative to calving (DRTC) to 212 ± 10 g/d at +29 DRTC to avoid excessive supply. Synthesis rate of plasma proteins was measured at –14, +4, +15, and +29 DRTC by measuring [13C]Phe isotopic...... enrichment in arterial plasma free Phe, total plasma proteins, and albumin after 3, 5, and 7 h of jugular ring[13C]Phe infusion. Plasma volume was determined at +4 and +29 DRTC by dilution of a [125I]BSA dose. Synthesis rate of tissue protein in biopsied rumen papillae was determined by measuring [13C...

  11. Finite-volume scheme for anisotropic diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Es, Bram van, E-mail: bramiozo@gmail.com [Centrum Wiskunde & Informatica, P.O. Box 94079, 1090GB Amsterdam (Netherlands); FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands" 1 (Netherlands); Koren, Barry [Eindhoven University of Technology (Netherlands); Blank, Hugo J. de [FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands" 1 (Netherlands)

    2016-02-01

    In this paper, we apply a special finite-volume scheme, limited to smooth temperature distributions and Cartesian grids, to test the importance of connectivity of the finite volumes. The area of application is nuclear fusion plasma with field line aligned temperature gradients and extreme anisotropy. We apply the scheme to the anisotropic heat-conduction equation, and compare its results with those of existing finite-volume schemes for anisotropic diffusion. Also, we introduce a general model adaptation of the steady diffusion equation for extremely anisotropic diffusion problems with closed field lines.

  12. Plasma-parameter measurements using neutral-particle-beam attenuation

    International Nuclear Information System (INIS)

    Foote, J.H.; Molvik, A.W.; Turner, W.C.

    1982-01-01

    Intense and energetic neutral-particle-beam injection used for fueling or heating magnetically confined, controlled-fusion experimental plasmas can also provide diagnostic measurements of the plasmas. The attenuation of an atomic beam (mainly from charge-exchange and ionization interactions) when passing through a plasma gives the plasma line density. Orthogonal arrays of highly collimated detectors of the secondary-electron-emission type have been used in magnetic-mirror experiments to measure neutral-beam attenuation along chords through the plasma volume at different radial and axial positions. The radial array is used to infer the radial plasma-density profile; the axial array, to infer the axial plasma-density profile and the ion angular distribution at the plasma midplane

  13. Structural imaging of the brain reveals decreased total brain and total gray matter volumes in obese but not in lean women with polycystic ovary syndrome compared to body mass index-matched counterparts.

    Science.gov (United States)

    Ozgen Saydam, Basak; Has, Arzu Ceylan; Bozdag, Gurkan; Oguz, Kader Karli; Yildiz, Bulent Okan

    2017-07-01

    To detect differences in global brain volumes and identify relations between brain volume and appetite-related hormones in women with polycystic ovary syndrome (PCOS) compared to body mass index-matched controls. Forty subjects participated in this study. Cranial magnetic resonance imaging and measurements of fasting ghrelin, leptin and glucagon-like peptide 1 (GLP-1), as well as GLP-1 levels during mixed-meal tolerance test (MTT), were performed. Total brain volume and total gray matter volume (GMV) were decreased in obese PCOS compared to obese controls (p lean PCOS and controls did not show a significant difference. Secondary analyses of regional brain volumes showed decreases in GMV of the caudate nucleus, ventral diencephalon and hippocampus in obese PCOS compared to obese controls (p lean patients with PCOS had lower GMV in the amygdala than lean controls (p PCOS, suggests volumetric reductions in global brain areas in obese women with PCOS. Functional studies with larger sample size are needed to determine physiopathological roles of these changes and potential effects of long-term medical management on brain structure of PCOS.

  14. BOOK REVIEW: Kinetic theory of plasma waves, homogeneous plasmas

    Science.gov (United States)

    Porkolab, Miklos

    1998-11-01

    The linear theory of plasma waves in homogeneous plasma is arguably the most mature and best understood branch of plasma physics. Given the recently revised version of Stix's excellent Waves in Plasmas (1992), one might ask whether another book on this subject is necessary only a few years later. The answer lies in the scope of this volume; it is somewhat more detailed in certain topics than, and complementary in many fusion research relevant areas to, Stix's book. (I am restricting these comments to the homogeneous plasma theory only, since the author promises a second volume on wave propagation in inhomogeneous plasmas.) This book is also much more of a theorist's approach to waves in plasmas, with the aim of developing the subject within the logical framework of kinetic theory. This may indeed be pleasing to the expert and to the specialist, but may be too difficult to the graduate student as an `introduction' to the subject (which the author explicitly states in the Preface). On the other hand, it may be entirely appropriate for a second course on plasma waves, after the student has mastered fluid theory and an introductory kinetic treatment of waves in a hot magnetized `Vlasov' plasma. For teaching purposes, my personal preference is to review the cold plasma wave treatment using the unified Stix formalism and notation (which the author wisely adopts in the present book, but only in Chapter 5). Such an approach allows one to deal with CMA diagrams early on, as well as to provide a framework to discuss electromagnetic wave propagation and accessibility in inhomogeneous plasmas (for which the cold plasma wave treatment is perfectly adequate). Such an approach does lack some of the rigour, however, that the author achieves with the present approach. As the author correctly shows, the fluid theory treatment of waves follows logically from kinetic theory in the cold plasma limit. I only question the pedagogical value of this approach. Otherwise, I welcome this

  15. Plasma Gelsolin Levels Decrease in Diabetic State and Increase upon Treatment with F-Actin Depolymerizing Versions of Gelsolin

    Directory of Open Access Journals (Sweden)

    Neeraj Khatri

    2014-01-01

    Full Text Available The study aims to map plasma gelsolin (pGSN levels in diabetic humans and mice models of type II diabetes and to evaluate the efficacy of gelsolin therapy in improvement of diabetes in mice. We report that pGSN values decrease by a factor of 0.45 to 0.5 in the blood of type II diabetic humans and mice models. Oral glucose tolerance test in mice models showed that subcutaneous administration of recombinant pGSN and its F-actin depolymerizing competent versions brought down blood sugar levels comparable to Sitagliptin, a drug used to manage hyperglycemic condition. Further, daily dose of pGSN or its truncated versions to diabetic mice for a week kept sugar levels close to normal values. Also, diabetic mice treated with Sitagliptin for 7 days, showed increase in their pGSN values with the decrease in blood glucose as compared to their levels at the start of treatment. Gelsolin helped in improving glycemic control in diabetic mice. We propose that gelsolin level monitoring and replacement of F-actin severing capable gelsolin(s should be considered in diabetic care.

  16. Radiative cooling of a cilindrical Z-pinch in the stage of plasma shett motion

    International Nuclear Information System (INIS)

    Gerusov, A.V.; Imshennik, V.S.

    1982-01-01

    Dinamics of a cylindrically symmetric Z-pinch in deiterium-neon mixture on the motion stage with volume radiation losses of energy of neon ions is considered. A two-temperature MHD model of Z-pinch is numerically calculated with various percentage of gases in mixture. It is found that radiation losses are essential in the dynamics of the discharqe. They decrease distribution of magnetic field and curreqt density. The temoerature of anode surface heated by absorbtion of radiation from the plasma sheath which forms in the discharge is obtained. The value of anode surface temperature prior to the arrival of the shock front is insufficient for operating of previously proposed mechanism of X-ray plasma focus regime. Another mechanism leading to X-ray regime being due to radiative cooiang as aiso suggested

  17. Decreased coenzyme Q10 concentration in plasma of children with cystic fibrosis

    NARCIS (Netherlands)

    Oudshoorn, J.H.; Lecluse, A.L.Y.; Berg, R. van den; Vaes, W.H.J.; Laag, J. van der; Houwen, R.H.J.

    2006-01-01

    OBJECTIVES: Coenzyme Q10 (CoQ10) is an effective lipophilic antioxidant and protects against lipid peroxidation by scavenging radicals. Patients with cystic fibrosis generally have fat malabsorption; thus, we hypothesized that overall plasma CoQ10 concentration in pediatric patients with cystic

  18. Sea Water Acidification Affects Osmotic Swelling, Regulatory Volume Decrease and Discharge in Nematocytes of the Jellyfish Pelagia noctiluca

    Directory of Open Access Journals (Sweden)

    Rossana Morabito

    2013-12-01

    Full Text Available Background: Increased acidification/PCO2 of sea water is a threat to the environment and affects the homeostasis of marine animals. In this study, the effect of sea water pH changes on the osmotic phase (OP, regulatory volume decrease (RVD and discharge of the jellyfish Pelagia noctiluca (Cnidaria, Scyphozoa nematocytes, collected from the Strait of Messina (Italy, was assessed. Methods: Isolated nematocytes, suspended in artificial sea water (ASW with pH 7.65, 6.5 and 4.5, were exposed to hyposmotic ASW of the same pH values and their osmotic response and RVD measured optically in a special flow through chamber. Nematocyte discharge was analyzed in situ in ASW at all three pH values. Results: At normal pH (7.65, nematocytes subjected to hyposmotic shock first expanded osmotically and then regulated their cell volume within 15 min. Exposure to hyposmotic ASW pH 6.5 and 4.5 compromised the OP and reduced or totally abrogated the ensuing RVD, respectively. Acidic pH also significantly reduced the nematocyte discharge response. Conclusion: Data indicate that the homeostasis and function of Cnidarians may be altered by environmental changes such as sea water acidification, thereby validating their use as novel bioindicators for the quality of the marine environment.

  19. Sea water acidification affects osmotic swelling, regulatory volume decrease and discharge in nematocytes of the jellyfish Pelagia noctiluca.

    Science.gov (United States)

    Morabito, Rossana; Marino, Angela; Lauf, Peter K; Adragna, Norma C; La Spada, Giuseppa

    2013-01-01

    Increased acidification/PCO2 of sea water is a threat to the environment and affects the homeostasis of marine animals. In this study, the effect of sea water pH changes on the osmotic phase (OP), regulatory volume decrease (RVD) and discharge of the jellyfish Pelagia noctiluca (Cnidaria, Scyphozoa) nematocytes, collected from the Strait of Messina (Italy), was assessed. Isolated nematocytes, suspended in artificial sea water (ASW) with pH 7.65, 6.5 and 4.5, were exposed to hyposmotic ASW of the same pH values and their osmotic response and RVD measured optically in a special flow through chamber. Nematocyte discharge was analyzed in situ in ASW at all three pH values. At normal pH (7.65), nematocytes subjected to hyposmotic shock first expanded osmotically and then regulated their cell volume within 15 min. Exposure to hyposmotic ASW pH 6.5 and 4.5 compromised the OP and reduced or totally abrogated the ensuing RVD, respectively. Acidic pH also significantly reduced the nematocyte discharge response. Data indicate that the homeostasis and function of Cnidarians may be altered by environmental changes such as sea water acidification, thereby validating their use as novel bioindicators for the quality of the marine environment. © 2014 S. Karger AG, Basel.

  20. Platelet rich plasma (PRP) induces chondroprotection via increasing autophagy, anti-inflammatory markers, and decreasing apoptosis in human osteoarthritic cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Moussa, Mayssam, E-mail: Moussa-mayssam@hotmail.com [Regenerative medicine and inflammation Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); Lajeunesse, Daniel, E-mail: daniel.lajeunesse@umontreal.ca [Research Centre in Osteoarthritis, Research Centre in Monteral University (Canada); Hilal, George, E-mail: George2266@gmail.com [Cancer and metabolism Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); El Atat, Oula, E-mail: oulaatat@hotmail.com [Regenerative medicine and inflammation Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); Haykal, Gaby, E-mail: Gaby.haykal@hdf.usj.edu.lb [Hotel Dieu de France, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); Serhal, Rim, E-mail: rim.basbous@gmail.com [Regenerative medicine and inflammation Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); Chalhoub, Antonio, E-mail: Mava.o@hotmail.com [Carantina Hospital, Beirut (Lebanon); Khalil, Charbel, E-mail: charbelk3@hotmail.com [Regenerative medicine and inflammation Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon); Alaaeddine, Nada, E-mail: Nada.aladdin@gmail.com [Regenerative medicine and inflammation Laboratory, Faculty of Medicine, Saint-Joseph University, Beirut (Lebanon)

    2017-03-01

    Objectives: Autophagy constitutes a defense mechanism to overcome aging and apoptosis in osteoarthritic cartilage. Several cytokines and transcription factors are linked to autophagy and play an important role in the degradative cascade in osteoarthritis (OA). Cell therapy such as platelet rich plasma (PRP) has recently emerged as a promising therapeutic tool for many diseases including OA. However, its mechanism of action on improving cartilage repair remains to be determined. The purpose of this study is to investigate the effect of PRP on osteoarthritic chondrocytes and to elucidate the mechanism by which PRP contributes to cartilage regeneration. Methods: Osteoarthritic chondrocytes were co-cultured with an increasing concentration of PRP obtained from healthy donors. The effect of PRP on the proliferation of chondrocytes was performed using cell counting and WST8 proliferation assays. Autophagy, apoptosis and intracellular level of IL-4, IL-10, and IL-13 were determined using flow cytometry analyses. Autophagy markers BECLIN and LC3II were also determined using quantitative polymerase chain reaction (qPCR). qPCR and ELISA were used to measure the expression of ADAMDTS-5, MMP3, MMP13, TIMP-1–2–3, aggregan, Collagen type 2, TGF-β, Cox-2, Il-6, FOXO1, FOXO3, and HIF-1 in tissues and co-cultured media. Results: PRP increased significantly the proliferation of chondrocytes, decreased apoptosis and increased autophagy and its markers along with its regulators FOXO1, FOXO3 and HIF-1 in osteoarthritic chondrocytes. Furthermore, PRP caused a dose-dependent significant decrease in MMP3, MMP13, and ADAMTS-5, IL-6 and COX-2 while increasing TGF-β, aggregan, and collagen type 2, TIMPs and intracellular IL-4, IL-10, IL-13. Conclusion: These results suggest that PRP could be a potential therapeutic tool for the treatment of OA. - Highlights: • Platelet Rich Plasma is suggested as a new treatment for osteoarthritis. • The proposed therapeutic effect is

  1. Platelet rich plasma (PRP) induces chondroprotection via increasing autophagy, anti-inflammatory markers, and decreasing apoptosis in human osteoarthritic cartilage

    International Nuclear Information System (INIS)

    Moussa, Mayssam; Lajeunesse, Daniel; Hilal, George; El Atat, Oula; Haykal, Gaby; Serhal, Rim; Chalhoub, Antonio; Khalil, Charbel; Alaaeddine, Nada

    2017-01-01

    Objectives: Autophagy constitutes a defense mechanism to overcome aging and apoptosis in osteoarthritic cartilage. Several cytokines and transcription factors are linked to autophagy and play an important role in the degradative cascade in osteoarthritis (OA). Cell therapy such as platelet rich plasma (PRP) has recently emerged as a promising therapeutic tool for many diseases including OA. However, its mechanism of action on improving cartilage repair remains to be determined. The purpose of this study is to investigate the effect of PRP on osteoarthritic chondrocytes and to elucidate the mechanism by which PRP contributes to cartilage regeneration. Methods: Osteoarthritic chondrocytes were co-cultured with an increasing concentration of PRP obtained from healthy donors. The effect of PRP on the proliferation of chondrocytes was performed using cell counting and WST8 proliferation assays. Autophagy, apoptosis and intracellular level of IL-4, IL-10, and IL-13 were determined using flow cytometry analyses. Autophagy markers BECLIN and LC3II were also determined using quantitative polymerase chain reaction (qPCR). qPCR and ELISA were used to measure the expression of ADAMDTS-5, MMP3, MMP13, TIMP-1–2–3, aggregan, Collagen type 2, TGF-β, Cox-2, Il-6, FOXO1, FOXO3, and HIF-1 in tissues and co-cultured media. Results: PRP increased significantly the proliferation of chondrocytes, decreased apoptosis and increased autophagy and its markers along with its regulators FOXO1, FOXO3 and HIF-1 in osteoarthritic chondrocytes. Furthermore, PRP caused a dose-dependent significant decrease in MMP3, MMP13, and ADAMTS-5, IL-6 and COX-2 while increasing TGF-β, aggregan, and collagen type 2, TIMPs and intracellular IL-4, IL-10, IL-13. Conclusion: These results suggest that PRP could be a potential therapeutic tool for the treatment of OA. - Highlights: • Platelet Rich Plasma is suggested as a new treatment for osteoarthritis. • The proposed therapeutic effect is

  2. Determination of free and total cyst(e)ine in plasma of dogs and cats.

    Science.gov (United States)

    Tôrres, Cristina L; Miller, Joshua W; Rogers, Quinton R

    2004-01-01

    In human blood, the amino acid cysteine forms disulfide bonds with itself and with other sulfhydryl compounds in their free form and with sulfhydryls in protein. Protein-bound cysteine is lost when plasma proteins are removed before amino acid analysis. The purpose of this study was to assess the time course and extent of cyst(e)ine (cysteine + half-cystine) loss in dog and cat plasma. An equal volume of 6% sulfosalicylic acid was added to plasma aliquots at 0, 2, 4, 10, 16, 24, 36, 48, 60, and 72 hours after separation of blood cells. Tris-2-carboxyethyl-phosphine hydrochloride (TCEP - HCl), a reducing agent, was used to regenerate total plasma cyst(e)ine after 3 months of sample storage (-20 degrees C). Initial free cyst(e)ine concentrations (mean +/- SEM) were higher in canine plasma (77 +/- 4 micromol/L) than in feline plasma (37 +/- 3 micromol/L). Free plasma cyst(e)ine concentrations in dogs and cats decreased after first-order kinetics, with a half-life of 23 and 69 hours, respectively. Total plasma cysteine after TCEP - HCl treatment was similar for dogs (290 micromol/L) and cats (296 micromol/L), but the percentage of free cysteine was higher (P = .02) in dogs (27%) than in cats (13%). Over half of the cyst(e)ine, homocysteine, cysteinylglycine, and glutathione were bound in vivo to plasma proteins. These results emphasize the importance of removing plasma proteins within 1 hour after blood collection for reliable assay of free plasma cyst(e)ine.

  3. Metrics for comparing plasma mass filters

    Energy Technology Data Exchange (ETDEWEB)

    Fetterman, Abraham J.; Fisch, Nathaniel J. [Department of Astrophysical Sciences, Princeton University, Princeton, New Jersey 08540 (United States)

    2011-10-15

    High-throughput mass separation of nuclear waste may be useful for optimal storage, disposal, or environmental remediation. The most dangerous part of nuclear waste is the fission product, which produces most of the heat and medium-term radiation. Plasmas are well-suited to separating nuclear waste because they can separate many different species in a single step. A number of plasma devices have been designed for such mass separation, but there has been no standardized comparison between these devices. We define a standard metric, the separative power per unit volume, and derive it for three different plasma mass filters: the plasma centrifuge, Ohkawa filter, and the magnetic centrifugal mass filter.

  4. Metrics for comparing plasma mass filters

    International Nuclear Information System (INIS)

    Fetterman, Abraham J.; Fisch, Nathaniel J.

    2011-01-01

    High-throughput mass separation of nuclear waste may be useful for optimal storage, disposal, or environmental remediation. The most dangerous part of nuclear waste is the fission product, which produces most of the heat and medium-term radiation. Plasmas are well-suited to separating nuclear waste because they can separate many different species in a single step. A number of plasma devices have been designed for such mass separation, but there has been no standardized comparison between these devices. We define a standard metric, the separative power per unit volume, and derive it for three different plasma mass filters: the plasma centrifuge, Ohkawa filter, and the magnetic centrifugal mass filter.

  5. Hemodynamic and ADH responses to central blood volume shifts in cardiac-denervated humans

    Science.gov (United States)

    Convertino, V. A.; Thompson, C. A.; Benjamin, B. A.; Keil, L. C.; Savin, W. M.; Gordon, E. P.; Haskell, W. L.; Schroeder, J. S.; Sandler, H.

    1990-01-01

    Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes designed to induce blood volume shifts in ten cardiac transplant recipients to assess the contribution of cardiac and vascular volume receptors in the control of ADH secretion. Each subject underwent 15 min of a control period in the seated posture, then assumed a lying posture for 30 min at 6 deg head down tilt (HDT) followed by 20 min of seated recovery. Venous blood samples and cardiac dimensions (echocardiography) were taken at 0 and 15 min before HDT, 5, 15, and 30 min of HDT, and 5, 15, and 30 min of seated recovery. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Resting plasma volume (PV) was measured by Evans blue dye and percent changes in PV during posture changes were calculated from changes in hematocrit. Heart rate (HR) and blood pressure (BP) were recorded every 2 min. Results indicate that cardiac volume receptors are not the only mechanism for the control of ADH release during acute blood volume shifts in man.

  6. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  7. Fusion Technology 1996. Proceedings. Volume 1 and 2

    International Nuclear Information System (INIS)

    Varandas, C.; Serra, F.

    1997-01-01

    The objective of these proceedings was to provide a platform for the exchange of information on the design, construction and operation of fusion experiments. The technology which is being developed for the next step devices and fusion reactors was also covered. Sections in volume 1 concern (A) first wall, divertors and vacuum systems; (B) plasma heating and control; (C) plasma engineering and control; and (D) experimental systems. The sections in volume 2 deal with (E) magnet and related power supplies; (F) fuel cycle and tritium processing systems; (G) blanket technology/materials; (H) assembly, remote handling and waste management and storage; and (I) safety and environment, and reactor studies

  8. Poloidal asymmetries in the limiter shadow plasma of the Alcator C tokamak. Volume 1

    International Nuclear Information System (INIS)

    LaBombard, B.

    1986-05-01

    This thesis investigates conditions which exist in the limiter shadow plasma of the Alcator C tokamak. The understanding of this edge plasma region is approached from both experimental and theoretical points of view. First, a general overview of edge plasma physical processes is presented. Simple edge plasma models and conditions which can theoretically result in a poloidally asymmetric edge plasma are discussed. A review of data obtained from previous diagnostics in the Alcator C edge plasma is then used to motivate the development of a new edge plasma diagnostic system (DENSEPACK) to experimentally investigate poloidal asymmetries in this region. The bulk of this thesis focuses on the marked poloidal asymmetries detected by this poloidal probe array and possible mechanisms which might support such asymmetries on a magnetic flux surface. In processing the probe data, some important considerations on fitting Langmuir probe characteristics are identified. The remainder of this thesis catalogues edge versus central plasma parameter dependences. Regression analysis techniques are applied to characterize edge density for various central plasma parameters. Edge plasma conditions during lower hybrid radio frequency heating and pellet injection are also discussed

  9. Nattokinase decreases plasma levels of fibrinogen, factor VII, and factor VIII in human subjects.

    Science.gov (United States)

    Hsia, Chien-Hsun; Shen, Ming-Ching; Lin, Jen-Shiou; Wen, Yao-Ke; Hwang, Kai-Lin; Cham, Thau-Ming; Yang, Nae-Cherng

    2009-03-01

    Nattokinase, a serine proteinase from Bacillus subtilis, is considered to be one of the most active functional ingredients found in natto. In this study, we hypothesized that nattokinase could reduce certain factors of blood clotting and lipids that are associated with an increase risk for cardiovascular disease (CVD). Thus, an open-label, self-controlled clinical trial was conducted on subjects of the following groups: healthy volunteers (Healthy Group), patients with cardiovascular risk factors (Cardiovascular Group), and patients undergoing dialysis (Dialysis Group). All subjects ingested 2 capsules of nattokinase (2000 fibrinolysis units per capsule) daily orally for 2 months. The laboratory measurements were performed on the screening visit and, subsequently, regularly after the initiation of the study. The intent-to-treat analysis was performed on all 45 enrolled subjects. By use of mixed model analysis, a significant time effect, but not group effect, was observed in the change from baseline of fibrinogen (P = .003), factor VII (P nattokinase. No significant changes of uric acid or notable adverse events were observed in any of the subjects. In summary, this study showed that oral administration of nattokinase could be considered as a CVD nutraceutical by decreasing plasma levels of fibrinogen, factor VII, and factor VIII.

  10. Predicting volume of distribution with decision tree-based regression methods using predicted tissue:plasma partition coefficients.

    Science.gov (United States)

    Freitas, Alex A; Limbu, Kriti; Ghafourian, Taravat

    2015-01-01

    Volume of distribution is an important pharmacokinetic property that indicates the extent of a drug's distribution in the body tissues. This paper addresses the problem of how to estimate the apparent volume of distribution at steady state (Vss) of chemical compounds in the human body using decision tree-based regression methods from the area of data mining (or machine learning). Hence, the pros and cons of several different types of decision tree-based regression methods have been discussed. The regression methods predict Vss using, as predictive features, both the compounds' molecular descriptors and the compounds' tissue:plasma partition coefficients (Kt:p) - often used in physiologically-based pharmacokinetics. Therefore, this work has assessed whether the data mining-based prediction of Vss can be made more accurate by using as input not only the compounds' molecular descriptors but also (a subset of) their predicted Kt:p values. Comparison of the models that used only molecular descriptors, in particular, the Bagging decision tree (mean fold error of 2.33), with those employing predicted Kt:p values in addition to the molecular descriptors, such as the Bagging decision tree using adipose Kt:p (mean fold error of 2.29), indicated that the use of predicted Kt:p values as descriptors may be beneficial for accurate prediction of Vss using decision trees if prior feature selection is applied. Decision tree based models presented in this work have an accuracy that is reasonable and similar to the accuracy of reported Vss inter-species extrapolations in the literature. The estimation of Vss for new compounds in drug discovery will benefit from methods that are able to integrate large and varied sources of data and flexible non-linear data mining methods such as decision trees, which can produce interpretable models. Graphical AbstractDecision trees for the prediction of tissue partition coefficient and volume of distribution of drugs.

  11. Experiments on screw-pinch plasmas with elongated cross section

    International Nuclear Information System (INIS)

    Lassing, H.W.

    1989-01-01

    In this thesis experiments are described carried out with SPICA II, a toroidal screw-pinch plasma device. this device is the last one in a series of plasma machines of the toroidal screw-pinch differing from its predecessor in its race-track shaped section. In devices of the type toroidal screw-pinch stable confinement is possible of plasmas with larger β values than in a tokamak discharge. In a pinch the plasma is screwed up, during the formation, in such a way that in a relatively small volume a plasma is formated with a high pressure. During the screwing up the plasma is heated by shock heating as well as adiabatic compression. With the modified snowplow model the density and temperature after the formation can be calculated, starting from the initial conditions. When all ions arrive into the plasma column, the density in the column is determined by the volume compression. First purpose of the experiments was to find a stable discharge. Subsequently discharges have been made with a high as possible β in order to investigate at which maximum β it is possible to confine screw-pinch plasmas stably. When these had been found, the nature and importance could be investigated of the processes following which the screw-pinch plasma looses its energy. (author), 75 res.; 95 figs.; 8 tabs

  12. Tokamak experimental power reactor conceptual design. Volume II

    International Nuclear Information System (INIS)

    1976-08-01

    Volume II contains the following appendices: (1) summary of EPR design parameters, (2) impurity control, (3) plasma computational models, (4) structural support system, (5) materials considerations for the primary energy conversion system, (6) magnetics, (7) neutronics penetration analysis, (8) first wall stress analysis, (9) enrichment of isotopes of hydrogen by cryogenic distillation, and (10) noncircular plasma considerations

  13. Abstracts of 13th International Congress on Plasma Physics (ICPP 2006). Published in 2 volumes

    International Nuclear Information System (INIS)

    Anon

    2006-01-01

    This report contains the presentation on the 13-th International Congress on Plasma Physics (ICPP 2006). Five main topics are covered: fundamental problems of plasma physics; fusion plasmas; plasmas in astrophysics and space physics; plasmas in applications and technologies; complex plasmas

  14. Abstracts of 13th International Congress on Plasma Physics (ICPP 2006). Published in 2 volumes

    Energy Technology Data Exchange (ETDEWEB)

    Anon,

    2006-07-01

    This report contains the presentation on the 13-th International Congress on Plasma Physics (ICPP 2006). Five main topics are covered: fundamental problems of plasma physics; fusion plasmas; plasmas in astrophysics and space physics; plasmas in applications and technologies; complex plasmas.

  15. VEGF-121 plasma level as biomarker for response to anti-angiogenetic therapy in recurrent glioblastoma.

    Science.gov (United States)

    Martini, Maurizio; de Pascalis, Ivana; D'Alessandris, Quintino Giorgio; Fiorentino, Vincenzo; Pierconti, Francesco; Marei, Hany El-Sayed; Ricci-Vitiani, Lucia; Pallini, Roberto; Larocca, Luigi Maria

    2018-05-10

    Vascular endothelial growth factor (VEGF) isoforms, particularly the diffusible VEGF-121, could play a major role in the response of recurrent glioblastoma (GB) to anti-angiogenetic treatment with bevacizumab. We hypothesized that circulating VEGF-121 may reduce the amount of bevacizumab available to target the heavier isoforms of VEGF, which are the most clinically relevant. We assessed the plasma level of VEGF-121 in a brain xenograft model, in human healthy controls, and in patients suffering from recurrent GB before and after bevacizumab treatment. Data were matched with patients' clinical outcome. In athymic rats with U87MG brain xenografts, the level of plasma VEGF-121 relates with tumor volume and it significantly decreases after iv infusion of bevacizumab. Patients with recurrent GB show higher plasma VEGF-121 than healthy controls (p = 0.0002) and treatment with bevacizumab remarkably reduced the expression of VEGF-121 in plasma of these patients (p = 0.0002). Higher plasma level of VEGF-121 was significantly associated to worse PFS and OS (p = 0.0295 and p = 0.0246, respectively). Quantitative analysis of VEGF-121 isoform in the plasma of patients with recurrent GB could be a promising predictor of response to anti-angiogenetic treatment.

  16. Oral and intraperitoneal administration of quercetin decreased lymphocyte DNA damage and plasma lipid peroxidation induced by TSA in vivo.

    Science.gov (United States)

    Chan, Shu-Ting; Lin, Yi-Chin; Chuang, Cheng-Hung; Shiau, Rong-Jen; Liao, Jiunn-Wang; Yeh, Shu-Lan

    2014-01-01

    Our previous study showed that quercetin enhances the anticancer effect of trichostatin A (TSA) in xenograft mice given quercetin intraperitoneally (10 mg/kg, 3 times/week). Herein, we investigate whether quercetin administered orally exerts such an effect and prevents the cytotoxic side effects of TSA. We found that quercetin given orally (20 and 100 mg/kg, 3 times/week) failed to enhance the antitumor effect of TSA although it increased the total quercetin concentration more than quercetin administered intraperitoneally in the plasma. The compound quercetin-3-glucuronide (Q3G) increased the most. However, quercetin administered intraperitoneally increased the total quercetin level in tumor tissues more than oral quercetin. Oral and intraperitoneal administration of quercetin similarly decreased lymphocyte DNA damage and plasma lipid peroxidation level induced by TSA. Furthermore, we found that the enhancing effect of Q3G on the antitumor effect of TSA and the incorporation of Q3G was less than that of quercetin in A549 cells. However, we found that A549 cells possessed the ability to convert Q3G to quercetin. In conclusion, different from quercetin administered intraperitoneally, quercetin administered orally failed to enhance the antitumor effect of TSA because of its metabolic conversion. However, it prevented TSA-induced DNA damage and lipid peroxidation.

  17. Nanoparticle formation in a low pressure argon/aniline RF plasma

    Science.gov (United States)

    Pattyn, C.; Kovacevic, E.; Hussain, S.; Dias, A.; Lecas, T.; Berndt, J.

    2018-01-01

    The formation of nanoparticles in low temperature plasmas is of high importance for different fields: from astrophysics to microelectronics. The plasma based synthesis of nanoparticles is a complex multi-scale process that involves a great variety of different species and comprises timescales ranging from milliseconds to several minutes. This contribution focuses on the synthesis of nanoparticles in a low temperature, low pressure capacitively coupled plasma containing mixtures of argon and aniline. Aniline is commonly used for the production of polyaniline, a material that belongs to the family of conductive polymers, which has attracted increasing interest in the last few years due to the large number of potential applications. The nanoparticles which are formed in the plasma volume and levitate there due to the collection of negative charges are investigated in this contribution by means of in-situ FTIR spectroscopy. In addition, the plasma is analyzed by means of plasma (ion) mass spectroscopy. The experiments reveal the possibility to synthesize nanoparticles both in continuous wave and in pulsed discharges. The formation of particles in the plasma volume can be suppressed by pulsing the plasma in a specific frequency range. The in-situ FTIR analysis also reveals the influence of the argon plasma on the characteristics of the nanoparticles.

  18. In vitro isotopic determination of diffusion volumes by transferrin labelled with indium 111. study of the correlation with SARI 125; Determination isotopique in vitro de volumes de diffusion par la transferrine marquee a l'indium 111. Etude de la correlation avec la SARI 125

    Energy Technology Data Exchange (ETDEWEB)

    Porot, C.L. [CHU Jean-Minjoz, Service de medecine nucleaire, 25 - Besancon (France); Angoue, O.R. [CHU Jean-Minjoz, laboratoire de biophysique et statistiques, 25 - Besancon (France); Berthetc, L.O. [CHU Jean-Minjoz, 25 - Besancon (France); Ungureanu, C.O.; Boulahdour, H.A.

    2010-07-01

    Serum albumin labeled with iodine 125 (S.A.R.I. 125) is the reference tracer used in measuring isotopic plasma volume. It has been causing a suspension of manufacturing leading to a supply disruption and resulting in the search for an alternative to measure plasma volume under consideration for measuring blood volume. Plasma transferrin labeled with indium-111 (Tf-{sup 111}In) is a potentially useful marker. To this end, we assessed the level of activity to be administered to determine a volume of distribution. The study of the correlation between the volume of distribution values obtained with S.A.R.I. 125 and Tf-{sup 111}In was then performed. Tf is an autologous protein which the labelling is easy and stable. Tf-{sup 111}In is a valid alternative to the S.A.R.I. 125 for measuring the plasma volume. The activity required for this examination shall not exceed 100 micro curies. (N.C.)

  19. Observation of a Relaxed Plasma State in a Quasi-Infinite Cylinder

    Science.gov (United States)

    Gray, T.; Brown, M. R.; Dandurand, D.

    2013-02-01

    A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v≥50km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of ∇×B=λB.

  20. Plasma arc pyrolysis of radioactive ion exchange resin

    International Nuclear Information System (INIS)

    Pickles, C.A.; Toguri, J.M.

    1992-01-01

    This paper reports on two ion exchange resins (IRN 77 and IRN 78) which were pyrolysed in a plasma-arc furnace. Both continuous and batch tests were performed. Volume reduction ratios of 10 to 1 and 10 to 3.5 were achieved for IRN 78 and IRN 77 respectively. The product of the resin pyrolysis was a char which contained the radioactive elements such as cobalt. The off-gases consisted of mainly hydrogen and carbon monoxide. There was a relatively small amount of dust in the off-gases. At the present time radioactive ion exchange resign is being kept in storage. The volume of this waste is increasing and it is important that the volume be reduce. The volume reduction ratio should be of the order of ten-to-one. Also, it is required that the radioactive elements can be collected or fixed in a form which could easily be disposed of. Plasma arc treatment offers considerable potential for the processing of the waste

  1. Radioimmunoassay of sodium cromoglycate in human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K; Gardner, J J; Lockley, W J.S.; Preston, J R; Wilkinson, D J [Fisons plc, Loughborough (UK). Pharmaceutical Div.

    1983-01-01

    A sensitive radioimmunoassay method for sodium cromoglycate in human plasma is described. The lowest quantifiable concentration of sodium cromoglycate is 0.93 nmol/l when 0.1 ml plasma samples are analysed. The range of the method is limited; both 0.01 and 0.1 ml volumes of plasma must be analysed to encompass the concentration range 0.93-139 nmol/l which may be encountered in plasma samples from patients and human volunteers. The method is specific for sodium cromoglycate as indicated by a low cross-reactivity of the anti-cromoglycate antiserum with a number of drugs.

  2. Decreases in Human Semen Quality with Age Among Healthy Men

    Energy Technology Data Exchange (ETDEWEB)

    Eskenazi, B.; Wyrobek, A.J.; Kidd, S.A.; Moore, L.; Young, S.S.; Moore, D.

    2001-12-01

    The objective of this report is to characterize the associations between age and semen quality among healthy active men after controlling for identified covariates. Ninety-seven healthy, nonsmoking men between 22 and 80 years without known fertility problems who worked for or retired from a large research laboratory. There was a gradual decrease in all semen parameters from 22-80 years of age. After adjusting for covariates, volume decreased 0.03 ml per year (p = 0.001); sperm concentration decreased 2.5% per year (p = 0.005); total count decreased 3.6% per year of age (p < 0.001); motility decreased 0.7% per year (P < 0.001); progressive motility decreased 3.1% per year (p < 0.001); and total progressively motile sperm decreased 4.8% per year (p < 0.001). In a group of healthy active men, semen volume, sperm concentration, total sperm count, and sperm motility decrease continuously between 22-80 years of age, with no evidence of a threshold.

  3. Changes with age in left ventricular function and volumes at rest and postexercise in postmenopausal women

    International Nuclear Information System (INIS)

    Yamada, Kiyoyasu; Isobe, Satoshi; Hirai, Makoto

    2006-01-01

    In postmenopausal women, it has been reported that the plasma estrogen levels diminish immediately after menopause, and that this phenomenon affects left ventricular (LV) function and volumes. However, the effects of age on LV function and volumes for a relatively short period in the postmenopausal women remain to be established. Electrocardiographically gated-myocardial single-photon emission computed tomography (SPECT) has recently provided accurate estimations of perfusion, cardiac systolic and diastolic functions. We investigated the age-related changes in LV function and volumes in postmenopausal women using electrocardiographically gated-myocardial scintigraphy. Twenty-two consecutive healthy postmenopausal women (mean age of 63.8±9.4 years, from 42 to 77 years) without cardiac disease underwent stress/rest technetium-99m tetrofosmin gated-myocardial SPECT with 16 frames per cardiac cycle at baseline and follow-up (1.0±0.3 years later). LV ejection fraction (LVEF) and LV volumes were calculated by quantitative gated SPECT (QGS) software. Fourier series were retained for the analysis of the volume curve. From this volume curve, we derived the following diastolic indices: peak filling rate (PFR) and time to PFR (TPFR). End-systolic volume index (ESVI) significantly decreased at postexercise (p=0.02) and tended to decrease at rest (p=0.06) from the baseline to the follow-up study. LVEF significantly increased at both postexercise (p=0.01) and rest (p=0.03) from the baseline to the follow-up study. The TPFR at rest tended to be prolonged from the baseline to the follow-up study (p=0.07). The absolute increase in LVEF at postexercise tended to decrease with age [4.8% (50s) vs. 3.4% (60s) vs. 1.2% (70s)]. An age-related change in cardiac performance is apparent at an approximately 1 year follow-up in postmenopausal women. In particular, the increase in LV systolic function tends to show the greatest value in the 50s subjects among the 3 generations. (author)

  4. Interface studies of N2 plasma-treated ZnSnO nanowire transistors using low-frequency noise measurements

    International Nuclear Information System (INIS)

    Kim, Seongmin; Janes, David B; Kim, Hwansoo; Ju, Sanghyun

    2013-01-01

    Due to the large surface-to-volume ratio of nanowires, the quality of nanowire–insulator interfaces as well as the nanowire surface characteristics significantly influence the electrical characteristics of nanowire transistors (NWTs). To improve the electrical characteristics by doping or post-processing, it is important to evaluate the interface characteristics and stability of NWTs. In this study, we have synthesized ZnSnO (ZTO) nanowires using the chemical vapor deposition method, characterized the composition of ZTO nanowires using x-ray photoelectron spectroscopy, and fabricated ZTO NWTs. We have characterized the current–voltage characteristics and low-frequency noise of ZTO NWTs in order to investigate the effects of interface states on subthreshold slope (SS) and the noise before and after N 2 plasma treatments. The as-fabricated device exhibited a SS of 0.29 V/dec and Hooge parameter of ∼1.20 × 10 −2 . Upon N 2 plasma treatment with N 2 gas flow rate of 40 sccm (20 sccm), the SS improved to 0.12 V/dec (0.21 V/dec) and the Hooge parameter decreased to ∼4.99 × 10 −3 (8.14 × 10 −3 ). The interface trap densities inferred from both SS and low-frequency noise decrease upon plasma treatment, with the highest flow rate yielding the smallest trap density. These results demonstrate that the N 2 plasma treatment decreases the interface trap states and defects on ZTO nanowires, thereby enabling the fabrication of high-quality nanowire interfaces. (paper)

  5. AC/DC/pulsed-power modulator for corona-plasma generation

    NARCIS (Netherlands)

    Ariaans, T.H.P.; Pemen, A.J.M.; Winands, G.J.J.; Heesch, van E.J.M.; Liu, Z.

    2009-01-01

    Gas-cleaning techniques using nonthermal plasma are slowly introduced into industry nowadays. In this paper, we present a novel power modulator for the efficient generation of large-volume corona plasma. No expensive high-voltage components are required. Switching is done at an intermediate voltage

  6. Noninductively Driven Tokamak Plasmas at Near-Unity Toroidal Beta

    International Nuclear Information System (INIS)

    Schlossberg, David J.; Bodner, Grant M.; Bongard, Michael W.; Burke, Marcus G.; Fonck, Raymond J.

    2017-01-01

    Access to and characterization of sustained, toroidally confined plasmas with a very high plasma-to-magnetic pressure ratio (β t ), low internal inductance, high elongation, and nonsolenoidal current drive is a central goal of present tokamak plasma research. Stable access to this desirable parameter space is demonstrated in plasmas with ultralow aspect ratio and high elongation. Local helicity injection provides nonsolenoidal sustainment, low internal inductance, and ion heating. Equilibrium analyses indicate β t up to ~100% with a minimum |B| well spanning up to ~50% of the plasma volume.

  7. The impact of BMI on sperm parameters and the metabolite changes of seminal plasma concomitantly.

    Science.gov (United States)

    Guo, Dan; Wu, Wei; Tang, Qiuqin; Qiao, Shanlei; Chen, Yiqiu; Chen, Minjian; Teng, Mengying; Lu, Chuncheng; Ding, Hongjuan; Xia, Yankai; Hu, Lingqing; Chen, Daozhen; Sha, Jiahao; Wang, Xinru

    2017-07-25

    The development of male infertility increased rapidly worldwide, which coinciding with the epidemic of obesity. However, the impact of weight abnormalities on sperm quality is still contestable. To assess the correlation between BMI and sperm parameters, we searched relevant articles in PubMed, Embase, Web of science, and Wanfang database published until June 2015 without language restriction. Otherwise, we also recruited some participants who attended fertility clinic as well as some general populations in this report. We performed a systematic review and meta-analysis about BMI and sperm parameters containing total sperm count, concentration, semen volume and sperm motility (overall and progressive). Metabolomic analysis of seminal plasma was performed to explore the mechanism from a new perspective. This study found standardized weighted mean differences (SMD) in sperm parameters (total sperm count, sperm concentration, and semen volume) of abnormal weight groups decreased to different degree compared to normal weight. Dose-response analysis found SMD of sperm count, sperm concentration and semen volume respectively fell 2.4%, 1.3% and 2.0% compared with normal weight for every 5-unit increase in BMI. Metabolomic analysis of seminal plasma showed that spermidine and spermine were likely to play a vital role in the spermatogenesis progress. This systematic review with meta-analysis has confirmed there was a relationship between BMI and sperm quality, suggesting obesity may be a detrimental factor of male infertility.

  8. Oral Administration of the Japanese Traditional Medicine Keishibukuryogan-ka-yokuinin Decreases Reactive Oxygen Metabolites in Rat Plasma: Identification of Chemical Constituents Contributing to Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Yosuke Matsubara

    2017-02-01

    Full Text Available Insufficient detoxification and/or overproduction of reactive oxygen species (ROS induce cellular and tissue damage, and generated reactive oxygen metabolites become exacerbating factors of dermatitis. Keishibukuryogan-ka-yokuinin (KBGY is a traditional Japanese medicine prescribed to treat dermatitis such as acne vulgaris. Our aim was to verify the antioxidant properties of KBGY, and identify its active constituents by blood pharmacokinetic techniques. Chemical constituents were quantified in extracts of KBGY, crude components, and the plasma of rats treated with a single oral administration of KBGY. Twenty-three KBGY compounds were detected in plasma, including gallic acid, prunasin, paeoniflorin, and azelaic acid, which have been reported to be effective for inflammation. KBGY decreased level of the diacron-reactive oxygen metabolites (d-ROMs in plasma. ROS-scavenging and lipid hydroperoxide (LPO generation assays revealed that gallic acid, 3-O-methylgallic acid, (+-catechin, and lariciresinol possess strong antioxidant activities. Gallic acid was active at a similar concentration to the maximum plasma concentration, therefore, our findings indicate that gallic acid is an important active constituent contributing to the antioxidant effects of KBGY. KBGY and its active constituents may improve redox imbalances induced by oxidative stress as an optional treatment for skin diseases.

  9. Equilibrium of rotating and nonrotating plasmas in tokamaks

    International Nuclear Information System (INIS)

    Pustovitov, V.D.

    2003-01-01

    One studied plasma equilibrium in tokamak in case of toroidal rotation. Rotation associated centrifugal force is shown to result in decrease of equilibrium limit as to β. One analyzes unlike opinion and considers its supports. It is shown that in possible case of local improvement of equilibrium conditions associated with special selection of profile of plasma rotation rate, the combined integral effect turns to be negative one. But in case of typical conditions, decrease of equilibrium β caused by plasma rotation is negligible one and one may ignore effect of plasma rotation on its equilibrium for hot plasma [ru

  10. Converging-barrel plasma accelerator

    International Nuclear Information System (INIS)

    Paine, T.O.

    1971-01-01

    The invention comprises a device for generating and accelerating plasma to extremely high velocity, while focusing the plasma to a decreasing cross section for attaining a very dense high-velocity plasma burst capable of causing nuclear fusion reactions. A converging coaxial accelerator-electrode configuration is employed with ''high-pressure'' gas injection in controlled amounts to achieve acceleration by deflagration and focusing by the shaped electromagnetic fields. (U.S.)

  11. Periodic long-range transport in a large volume dc glow discharge dusty plasma

    International Nuclear Information System (INIS)

    Thomas, Edward Jr.; Amatucci, William E.; Compton, Christopher; Christy, Brian; Jackson, Jon David

    2003-01-01

    In an earlier paper, the authors reported on observations of a variety of particle transport phenomena observed in DUPLEX--the DUsty PLasma EXperiment at the Naval Research Laboratory [E. Thomas, Jr., W. E. Amatucci, C. Compton, and B. Christy, Phys. Plasmas 9, 3154 (2002)]. DUPLEX is a large, transparent polycarbonate cylinder that is 40 cm in radius and 80 cm in height. dc glow discharge argon plasmas are generated in DUPLEX. In this paper, the authors expand upon one particular feature of particle transport in DUPLEX, the long-range (i.e., greater than 15 cm), periodic (T∼2.5 min) transport of suspended alumina particles through the plasma. A detailed description of this particle motion through the plasma is presented. Finally, a qualitative model describing the phenomena that lead to this transport is also given

  12. Dexamethasone decreases plasma levels of the prochiral fenbendazole and its chiral and achiral metabolites in sheep.

    Science.gov (United States)

    Sánchez, S; Small, J; Jones, D G; McKellar, Q A

    2003-07-01

    1. The effect of co-administration of either short- or long-acting formulations of DXM on hepatic function and the plasma pharmacokinetic behaviour of prochiral fenbendazole (FBZ) and its metabolites was evaluated in sheep. 2. Neither DXM treatment markedly affected any of the biochemical markers of hepatic function tested. In contrast, both formulations significantly modified the plasma pharmacokinetic behaviour of FBZ and its metabolites. 3. Plasma FBZ concentrations and the associated area under the time-concentration curves were significantly lower, although the plasma detection period was longer (72 versus 48 h) in the DXM pretreated animals compared with those given FBZ alone. 4. DXM also appeared to alter the pattern of FBZ absorption, possibly through effects on abomasal pH. The shape of the plasma concentration-time curves for oxfendazole (OFZ) and fenbendazole sulphone (FBZSO(2)) were similar to FBZ, raising the possibility that DXM treatment may have altered the liver biotransformation of the parent drug. 5. The concentrations of the (+) chiral metabolite of OFZ were significantly lower in DXM pretreated animals compared with those given FBZ alone. The trend was similar for the (-) antipode, although the differences between DXM pretreated and non-pretreated animals were not statistically significant.

  13. Monocrotophos pesticide decreases the plasma levels of total 3,3',5-triiodo-l-thyronine and alters the expression of genes associated with the thyroidal axis in female goldfish (Carassius auratus.

    Directory of Open Access Journals (Sweden)

    Xiaona Zhang

    Full Text Available Our recent study showed that monocrotophos (MCP pesticide disrupted the hypothalamic-pituitary-thyroid (HPT axis in male goldfish (Carassius auratus; however, the effects of MCP on the thyroid system in female goldfish are remain unclear. In the present study, plasma thyroid hormone (TH and thyroid-stimulating hormone (TSH levels were evaluated in female goldfish exposed to 0.01, 0.10, and 1.00 mg/L of 40% MCP-based pesticide for 21 days in a semi-static exposure system. Expression profiles of HPT axis-responsive genes, including transthyretin (ttr, deiodinases (d1, d2, and d3, tshβ, thyrotropin-releasing hormone (trh, and corticotrophin-releasing hormone (crh, were determined. The results indicated that MCP decreased the plasma levels of total 3,3',5-triiodo-l-thyronine (TT3 and the ratio of TT3 to total 3,3',5,5'-l-thyroxine (TT4, and induced alternative expression of TH-related genes. Exposure to 0.01 and 0.10 mg/L MCP pesticide resulted in the up-regulation of ttr mRNA. The reduction of plasma TT3 levels was partly attributed to an increase in the metabolism of T3 in the liver, as revealed by the highly elevated hepatic d1 and d3 mRNA levels in the MCP treatment groups, and the expression of hepatic d3 showed a negative correlation with the plasma TT3/TT4 levels in females. Moreover, the plasma TSH levels were lower in females exposed to 0.01 and 0.10 mg/L MCP pesticide, whereas the up-regulation of tshβ mRNA levels was compensated by the decreased plasma TT3 levels. These results indicated that MCP had the potential to influence several pathways of HPT axis homeostasis in female goldfish.

  14. Flute instability in the plasma shell of the earth's magnetosphere

    International Nuclear Information System (INIS)

    Ivanov, V.N.; Pokhotelov, O.A.

    1987-01-01

    In the plasma shell of the earth's magnetosphere, the surfaces of constant pressure may not coincide with surfaces of constant specific volume. This circumstance forces a reexamination of the theory for the flute instability, in which the pressure has been assumed to remain constant on surfaces of constant specific volume. The MHD equations for flute waves in a curvilinear magnetic field are used to show that an instability of a new type, with a pressure which does not remain constant on surfaces of constant specific volume, can occur in the plasma shell of the magnetosphere. An expression is derived for the growth rate of this instability. Analysis of the equation also shows that perturbations with wavelengths shorter than the ion Larmor radius are stable by virtue of magnetodrift effects. The growth rates of the flute instabilities are calculated for both a dipole magnetic field and an arbitrary magnetic-field configuration. Growth rates calculated for typical values of the characteristics of the earth's plasma shell are reported

  15. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading...... of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males...... from whom pulmonary capillary wedge pressure (PCWP), central venous pressure and SV (via thermodilution) were obtained while central blood volume was reduced via lower-body negative pressure (LBNP) during normothermia, whole-body heating (increase in blood temperature 1 degrees C), and during whole...

  16. Improvement of the mechanical properties of spark plasma sintered hap bioceramics by decreasing the grain size and by adding multi-walled carbon nanotubes

    Directory of Open Access Journals (Sweden)

    Veljović Đ.

    2013-01-01

    Full Text Available Composites based on HAP and oxidized multi-walled carbon nanotubes (o-MWCNT and monophase HAP materials were processed by spark plasma sintering. Starting from stoichiometric nano-sized HAP powder, monophase bioceramics were obtained with a density close to the theoretical one and with an average grain size of several hundred nanometers to micron dimensions. It was shown that decreasing the sintering temperature resulted in a decrease of the grain size, which affected an increase in the fracture toughness and hardness. The fracture toughness of an HAP/ o-MWCNT bioceramic processed at 900°C for only 5 min was 30 % higher than that of monophase HAP materials obtained under the same conditions. The addition of MWCNT during SPS processing of HAP materials caused a decrease in the grain size to the nano-dimension, which was one of the reasons for the improved mechanical properties. [Projekat Ministarstva nauke Republike Srbije, br. III45019 i FP7-REGPOT-2009-1 NANOTECH FTM, Grant Agreement Number: 245916

  17. On lower hybrid wave scattering by plasma density fluctuations

    International Nuclear Information System (INIS)

    Petrzilka, V.

    1988-01-01

    The scattering of lower hybrid waves on plasma density fluctuations in a thin turbulent layer at the plasma periphery is studied numerically. The lower hybrid waves are supposed to be radiated by a four-waveguide grill used on the CASTOR tokamak. A great number of calculated scattered wave spectra show that the scattered spectrum shifts to larger values of the parallel-to-magnetic-field component of the wave vector (to slower waves) with increasing central plasma density and with the decreasing safety factor at the boundary. As known, this shift of the wave spectra results in a decrease in current drive efficiency. The current drive efficiency will hence decrease with growing plasma density and with decreasing safety factor. (J.U.). 2 figs., 4 refs

  18. Effect of cesium seeding on hydrogen negative ion volume production

    International Nuclear Information System (INIS)

    Bacal, M.; Balghiti-Sube, F. El; Elizarov, L. I.; Tontegode, A. J.

    1998-01-01

    The effect of cesium vapor partial pressure on the plasma parameters has been studied in the dc hybrid negative ion source ''CAMEMBERT III.'' The cesium vapor pressure was varied up to 10 -5 Torr and was determined by a surface ionization gauge in the absence of the discharge. The negative ion relative density measured by laser photodetachment in the center of the plasma extraction region increases by a factor of four when the plasma is seeded with cesium. However the plasma density and the electron temperature (determined using a cylindrical electrostatic probe) are reduced by the cesium seeding. As a result, the negative ion density goes up by a factor of two at the lowest hydrogen pressure studied. The velocity of the directed negative ion flow to the plasma electrode, determined from two-laser beam photodetachment experiments, appears to be affected by the cesium seeding. The variation of the extracted negative ion and electron currents versus the plasma electrode bias will also be reported for pure hydrogen and cesium seeded plasmas. The cesium seeding leads to a dramatic reduction of the electron component, which is consistent with the reduced electron density and temperature. The negative ion current is enhanced and a goes through a maximum at plasma electrode bias lower than 1 V. These observations lead to the conclusion that the enhancement of pure volume production occurs in this type of plasma. Possible mechanisms for this type of volume process will be discussed

  19. Stability in high gain plasmas in DIII-D

    International Nuclear Information System (INIS)

    Lazarus, E.A.; Houlberg, W.A.; Murakami, M.; Wade, M.R.

    1996-10-01

    Fusion power gain has been increased by a factor of 3 in DIII-D plasmas through the use of strong discharge shaping and tailoring of the pressure and current density profiles. H-mode plasmas with weak or negative central magnetic shear are found to have neoclassical ion confinement throughout most of the plasma volume. Improved MHD stability is achieved by controlling the plasma pressure profile width. The highest fusion power gain Q (ratio of fusion power to input power) in deuterium plasmas was 0.0015, which extrapolates to an equivalent Q of 0.32 in a deuterium-tritium plasma and is similar to values achieved in tokamaks of larger size and magnetic fields

  20. Pharmacokinetic drivers of toxicity for basic molecules: Strategy to lower pKa results in decreased tissue exposure and toxicity for a small molecule Met inhibitor

    International Nuclear Information System (INIS)

    Diaz, Dolores; Ford, Kevin A.; Hartley, Dylan P.; Harstad, Eric B.; Cain, Gary R.; Achilles-Poon, Kirsten; Nguyen, Trung; Peng, Jing; Zheng, Zhong; Merchant, Mark; Sutherlin, Daniel P.; Gaudino, John J.; Kaus, Robert; Lewin-Koh, Sock C.; Choo, Edna F.; Liederer, Bianca M.; Dambach, Donna M.

    2013-01-01

    Several toxicities are clearly driven by free drug concentrations in plasma, such as toxicities related to on-target exaggerated pharmacology or off-target pharmacological activity associated with receptors, enzymes or ion channels. However, there are examples in which organ toxicities appear to correlate better with total drug concentrations in the target tissues, rather than with free drug concentrations in plasma. Here we present a case study in which a small molecule Met inhibitor, GEN-203, with significant liver and bone marrow toxicity in preclinical species was modified with the intention of increasing the safety margin. GEN-203 is a lipophilic weak base as demonstrated by its physicochemical and structural properties: high LogD (distribution coefficient) (4.3) and high measured pKa (7.45) due to the basic amine (N-ethyl-3-fluoro-4-aminopiperidine). The physicochemical properties of GEN-203 were hypothesized to drive the high distribution of this compound to tissues as evidenced by a moderately-high volume of distribution (Vd > 3 l/kg) in mouse and subsequent toxicities of the compound. Specifically, the basicity of GEN-203 was decreased through addition of a second fluorine in the 3-position of the aminopiperidine to yield GEN-890 (N-ethyl-3,3-difluoro-4-aminopiperidine), which decreased the volume of distribution of the compound in mouse (Vd = 1.0 l/kg), decreased its tissue drug concentrations and led to decreased toxicity in mice. This strategy suggests that when toxicity is driven by tissue drug concentrations, optimization of the physicochemical parameters that drive tissue distribution can result in decreased drug concentrations in tissues, resulting in lower toxicity and improved safety margins. -- Highlights: ► Lower pKa for a small molecule: reduced tissue drug levels and toxicity. ► New analysis tools to assess electrostatic effects and ionization are presented. ► Chemical and PK drivers of toxicity can be leveraged to improve safety.

  1. Electrical disruption in toroidal plasma of hydrogen

    International Nuclear Information System (INIS)

    Roberto, M.; Silva, C.A.B.; Goes, L.C.S.; Sudano, J.P.

    1991-01-01

    The initial phase of ionization of a toroidal plasma produced in hydrogen was investigated using zero-dimensional model. The model describes the temporal evolution of plasma by spatial medium of particle density and temperature, on whole plasma volume. The energy and particle (electrons and ions) balance equations are considered. The electron loss is due to ambipolar diffusion in the presence of magnetic field. The electron energy loss involves ionization, Coulomb interaction and diffusion. The ohmic heating converter gives the initial voltage necessary to disruption. (M.C.K.)

  2. Improvement of confinement characteristics of tokamak plasma by controlling plasma-wall interactions

    International Nuclear Information System (INIS)

    Sengoku, Seio

    1985-08-01

    Relation between plasma-wall interactions and confinement characteristics of a tokamak plasma with respect to both impurity and fuel particle controls is discussed. Following results are obtained from impurity control studies: (1) Ion sputtering is the dominant mechanism of impurity release in a steady state tokamak discharge. (2) By applying carbon coating on entire first wall of DIVA tokamak, dominant radiative region is concentrated more in boundary plasma resulting a hot peripheral plasma with cold boundary plasma. (3) A physical model of divertor functions about impurity control is empilically obtained. By a computer simulation based on above model with respect to divertor functions for JT-60 tokamak, it is found that the allowable electron temperature of the divertor plasma is not restricted by a condition that the impurity release due to ion sputtering does not increase continuously. (4) Dense and cold divertor plasma accompanied with strong remote radiative cooling was diagnosed along the magnetic field line in the simple poloidal divertor of DOUBLET III tokamak. Strong particle recycling region is found to be localized near the divertor plate. by and from particle control studies: (1) The INTOR scaling on energy confinement time is applicable to high density region when a core plasma is fueled directly by solid deuterium pellet injection in DOUBLET III tokamak. (2) As remarkably demonstrated by direct fueling with pellet injection, energy confinement characteristics can be improved at high density range by decreasing particle deposition at peripheral plasma in order to reduce plasma-wall interaction. (3) If the particle deposition at boundary layer is necessarily reduced, the electron temperature at the boundary or divertor region increases due to decrease of the particle recycling and the electron density there. (J.P.N.)

  3. Electromagnetic-wave absorption by inhomogeneous, collisional plasmas

    International Nuclear Information System (INIS)

    Gregoire, D.J.; Santoru, J.; Schumacher, R.W.

    1990-01-01

    Unmagnetized, collisional plasmas can be used as broadband EM-wave absorbers or refractors. In the absorption process, plasma electrons are first accelerated by the EM-wave fields and then collide with background-gas molecules, thereby transferring energy from the EM waves to the gas. A plasma absorber has several advantages compared to conventional materials. A plasma can be turned on and off very rapidly, thereby switching between absorbing and transparent conditions. Calculations indicate that plasma absorbers can also be tailored to provide broadband absorption (>40 dB) over multiple octaves. The authors have developed a one-dimensional model and a computer code to calculate the net power reflected from a plasma-enclosed EM-wave-reflecting target. They included three contributions to the reflected EM-wave power: reflections from the vacuum-plasma interface; reflections from the bulk plasma volume; and reflection of the attenuated EM wave that is transmitted through the plasma and reflected by the target

  4. Electromagnetic interactions in an electron-hole plasma

    International Nuclear Information System (INIS)

    1977-01-01

    Certain problems electromagnetic interactions both of external SHF radiation with an electron-hole (eh) plasma and in the plasma itself are considered. The production and properties of a non-equilibrium eh plasma in semiconductors, pinch effect in a plasma of solids, strong electric fields in a plasma of inhomogeneous semiconductors and heat effects in a semiconductor plasma are discussed. The influence of a surface, kinetics of recombination processes in the semiconductor volume and the plasma statistics the spatial distribution of carriers, current characteristics and plasma recombination radiation under the conditions of pinch effect is described. The diagnostics methods of the phenomena are presented. The behaviour of diode structures with pn transitions in strong SHF fields is discussed. Special attention is paid to collective phenomena in the plasma of semiconductor devices and the variation of carrier density in strong fields. The appearance of electromotive force in inhomogeneous diode structures placed in strong SHF fields is considered

  5. Observation of a relaxed plasma state in a quasi-infinite cylinder.

    Science.gov (United States)

    Gray, T; Brown, M R; Dandurand, D

    2013-02-22

    A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v ≥ 50 km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of [Symbol: see text] × B = λB.

  6. Substrate Effect on Plasma Clean Efficiency in Plasma Enhanced Chemical Vapor Deposition System

    Directory of Open Access Journals (Sweden)

    Shiu-Ko JangJian

    2007-01-01

    Full Text Available The plasma clean in a plasma-enhanced chemical vapor deposition (PECVD system plays an important role to ensure the same chamber condition after numerous film depositions. The periodic and applicable plasma clean in deposition chamber also increases wafer yield due to less defect produced during the deposition process. In this study, the plasma clean rate (PCR of silicon oxide is investigated after the silicon nitride deposited on Cu and silicon oxide substrates by remote plasma system (RPS, respectively. The experimental results show that the PCR drastically decreases with Cu substrate compared to that with silicon oxide substrate after numerous silicon nitride depositions. To understand the substrate effect on PCR, the surface element analysis and bonding configuration are executed by X-ray photoelectron spectroscopy (XPS. The high resolution inductively coupled plasma mass spectrometer (HR-ICP-MS is used to analyze microelement of metal ions on the surface of shower head in the PECVD chamber. According to Cu substrate, the results show that micro Cu ion and the CuOx bonding can be detected on the surface of shower head. The Cu ion contamination might grab the fluorine radicals produced by NF3 ddissociation in the RPS and that induces the drastic decrease on PCR.

  7. Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources

    International Nuclear Information System (INIS)

    Kuppel, S.; Matsushita, D.; Hatayama, A.; Bacal, M.

    2011-01-01

    This numerical study focuses on the physical mechanisms involved in the extraction of volume-produced H - ions from a steady state laboratory negative hydrogen ion source with one opening in the plasma electrode (PE) on which a dc-bias voltage is applied. A weak magnetic field is applied in the source plasma transversely to the extracted beam. The goal is to highlight the combined effects of the weak magnetic field and the PE bias voltage (upon the extraction process of H - ions and electrons). To do so, we focus on the behavior of electrons and volume-produced negative ions within a two-dimensional model using the particle-in-cell method. No collision processes are taken into account, except for electron diffusion across the magnetic field using a simple random-walk model at each time step of the simulation. The results show first that applying the magnetic field (without PE bias) enhances H - ion extraction, while it drastically decreases the extracted electron current. Secondly, the extracted H - ion current has a maximum when the PE bias is equal to the plasma potential, while the extracted electron current is significantly reduced by applying the PE bias. The underlying mechanism leading to the above results is the gradual opening by the PE bias of the equipotential lines towards the parts of the extraction region facing the PE. The shape of these lines is due originally to the electron trapping by the magnetic field.

  8. Numerical analysis of electronegative plasma in the extraction region of negative hydrogen ion sources

    Science.gov (United States)

    Kuppel, S.; Matsushita, D.; Hatayama, A.; Bacal, M.

    2011-01-01

    This numerical study focuses on the physical mechanisms involved in the extraction of volume-produced H- ions from a steady state laboratory negative hydrogen ion source with one opening in the plasma electrode (PE) on which a dc-bias voltage is applied. A weak magnetic field is applied in the source plasma transversely to the extracted beam. The goal is to highlight the combined effects of the weak magnetic field and the PE bias voltage (upon the extraction process of H- ions and electrons). To do so, we focus on the behavior of electrons and volume-produced negative ions within a two-dimensional model using the particle-in-cell method. No collision processes are taken into account, except for electron diffusion across the magnetic field using a simple random-walk model at each time step of the simulation. The results show first that applying the magnetic field (without PE bias) enhances H- ion extraction, while it drastically decreases the extracted electron current. Secondly, the extracted H- ion current has a maximum when the PE bias is equal to the plasma potential, while the extracted electron current is significantly reduced by applying the PE bias. The underlying mechanism leading to the above results is the gradual opening by the PE bias of the equipotential lines towards the parts of the extraction region facing the PE. The shape of these lines is due originally to the electron trapping by the magnetic field.

  9. The plasma properties and electron emission characteristics of near-zero differential resistance of hollow cathode-based plasma contactors with a discharge chamber

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Kan, E-mail: xiekan@bit.edu.cn [School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081 (China); Farnell, Casey C.; Williams, John D. [Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80524 (United States)

    2014-08-15

    The formation of electron emission-bias voltage (I-V) characteristics of near-zero differential resistance in the cathodic plasma contactor for bare electrodynamic tether applications, based on a hollow cathode embedded in a ring-cusp ionization stage, is studied. The existence of such an I-V regime is important to achieve low impedance performance without being affected by the space plasma properties for a cathodic plasma contactor. Experimental data on the plasma structure and properties downstream from the ionization stage are presented as functions of the xenon flow rate and the electron emission current. The electrons were emitted from the cathode to the cylindrical vacuum chamber wall (r = 0.9 m) under ≈10{sup −5 }Torr of vacuum pressure. The ring-cusp configuration selected for the plasma contactor created a 125-Gauss axial field near the cathode orifice, along with a large-volume 50-Gauss magnitude pocket in the stage. A baseline ion energy cost of ≈300 eV/ion was measured in the ionization stage when no electrons were emitted to the vacuum chamber wall. In addition, the anode fall growth limited the maximum propellant unitization to below ≈75% in the discharge loss curves for this ion stage. Detailed measurements on the plasma properties were carried out for the no-electron emission and 3 A emission conditions. The experimental data are compared with 1-D models, and the effectiveness of the model is discussed. The four key issues that played important roles in the process of building the near-zero different resistance I-V regime are: a significant amount of ionization by the emission electrons, a decrease in the number of reflected electrons in the plume, the electron-temperature increment, and low initial ion energy at the source outlet.

  10. First plasmas in the TJ-II flexible Heliac

    International Nuclear Information System (INIS)

    Alejaldre, C.; Alonso, J.; Almoguera, L.

    1999-01-01

    First plasmas have been successfully achieved in the TJ-II stellarator using electron cyclotron resonance heating (f = 53.2 GHz, P ECRH = 250 kW). Initial experiments have explored the TJ-II flexibility in a wide range of plasma volumes, different rotational transform and magnetic well values. In this paper, the main results of this campaign are presented and, in particular, the influence of plasma wall interaction phenomena on TJ-II operation is discussed briefly. (author)

  11. Rho family GTP binding proteins are involved in the regulatory volume decrease process in NIH3T3 mouse fibroblasts

    DEFF Research Database (Denmark)

    Pedersen, Stine F; Beisner, Kristine H; Willumsen, Berthe M

    2002-01-01

    The role of Rho GTPases in the regulatory volume decrease (RVD) process following osmotic cell swelling is controversial and has so far only been investigated for the swelling-activated Cl- efflux. We investigated the involvement of RhoA in the RVD process in NIH3T3 mouse fibroblasts, using wild......-type cells and three clones expressing constitutively active RhoA (RhoAV14). RhoAV14 expression resulted in an up to fourfold increase in the rate of RVD, measured by large-angle light scattering. The increase in RVD rate correlated with RhoAV14 expression. RVD in wild-type cells was unaffected by the Rho...

  12. Study on plasma melting treatment of crucibles, ceramic filter elements, asbestos, and fly ash

    International Nuclear Information System (INIS)

    Hoshi, Akiko; Nakasio, Nobuyuki; Nakajima, Mikio

    2004-01-01

    The Japan Atomic Energy Research Institute (JAERI) decided to adopt an advanced volume reduction program for low-level radioactive wastes. In this program, inorganic wastes are converted to stable glassy products suitable for disposal by a plasma melting system in the Waste Volume Reduction Facilities (WVRF). High melting point wastes such as refractories are excluded from the plasma melting treatment in the WVRF, and wastes difficult to handle such as asbestos are also excluded. However, it is describable to apply the plasma melting treatment to these wastes for stabilization and volume reduction from the viewpoint of disposal. In this paper, plasma melting test of crucibles, ceramic filter elements, asbestos, and simulated fly ashes were carried out as a part of technical support for WVRF. The plasma melting treatment was applicable for crucibles and asbestos because homogeneous and glassy products were obtained by controlling of waste and loading condition. It was found that SiC in ceramic filter elements was volatile with a plasma torch with inert gas, and adding reducer was ineffective against stabilizing volatile metals such as Zn, Pb in a solidified product in the melting test of simulated fly ash. (author)

  13. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  14. Risk of iron overload is decreased in beating heart coronary artery surgery compared to conventional bypass.

    Science.gov (United States)

    Mumby, S; Koh, T W; Pepper, J R; Gutteridge, J M

    2001-11-29

    Conventional cardiopulmonary bypass surgery (CCPB) increases the iron loading of plasma transferrin often to a state of plasma iron overload, with the presence of low molecular mass iron. Such iron is a potential risk factor for oxidative stress and microbial virulence. Here we assess 'off-pump' coronary artery surgery on the beating heart for changes in plasma iron chemistry. Seventeen patients undergoing cardiac surgery using the 'Octopus' myocardial wall stabilisation device were monitored at five time points for changes in plasma iron chemistry. This group was further divided into those (n=9) who had one- or two- (n=8) vessel grafts, and compared with eight patients undergoing conventional coronary artery surgery. Patients undergoing beating heart surgery had significantly lower levels of total plasma non-haem iron, and a decreased percentage saturation of their transferrin at all time points compared to conventional bypass patients. Plasma iron overload occurred in only one patient undergoing CCPB. Beating heart surgery appears to decrease red blood cell haemolysis, and tissue damage during the operative procedures and thereby significantly decreases the risk of plasma iron overload associated with conventional bypass.

  15. A Seemingly Simple Task: Filling a Solenoid Volume in Vacuum with Dense Plasma

    International Nuclear Information System (INIS)

    Anders, Andre; Kauffeldt, Marina; Roy, Prabir; Oks, Efim

    2010-01-01

    Space-charge neutralization of a pulsed, high-current ion beam is required to compress and focus the beam on a target for warm dense matter physics or heavy ion fusion experiments. We described attempts to produce dense plasma in and near the final focusing solenoid through which the ion beam travels, thereby providing an opportunity for the beam to acquire the necessary charge-compensating electrons. Among the options are plasma injection from four pulsed vacuum arc sources located outside the solenoid, and using a high current (> 4 kA) pulsed vacuum arc plasma from a ring cathode near the edge of the solenoid. The plasma distribution is characterized by photographic means and by an array of movable Langmuir probes. The plasma is produced at several cathode spots distributed azimuthally on the ring cathode. Beam neutralization and compression are accomplished, though issues of density, uniformity, and pulse-to-pulse reproducibly remain to be solved.

  16. Magnetohydrodynamic simulation study of plasma jets and plasma-surface contact in coaxial plasma accelerators

    Science.gov (United States)

    Subramaniam, Vivek; Raja, Laxminarayan L.

    2017-06-01

    Recent experiments by Loebner et al. [IEEE Trans. Plasma Sci. 44, 1534 (2016)] studied the effect of a hypervelocity jet emanating from a coaxial plasma accelerator incident on target surfaces in an effort to mimic the transient loading created during edge localized mode disruption events in fusion plasmas. In this paper, we present a magnetohydrodynamic (MHD) numerical model to simulate plasma jet formation and plasma-surface contact in this coaxial plasma accelerator experiment. The MHD system of equations is spatially discretized using a cell-centered finite volume formulation. The temporal discretization is performed using a fully implicit backward Euler scheme and the resultant stiff system of nonlinear equations is solved using the Newton method. The numerical model is employed to obtain some key insights into the physical processes responsible for the generation of extreme stagnation conditions on the target surfaces. Simulations of the plume (without the target plate) are performed to isolate and study phenomena such as the magnetic pinch effect that is responsible for launching pressure pulses into the jet free stream. The simulations also yield insights into the incipient conditions responsible for producing the pinch, such as the formation of conductive channels. The jet-target impact studies indicate the existence of two distinct stages involved in the plasma-surface interaction. A fast transient stage characterized by a thin normal shock transitions into a pseudo-steady stage that exhibits an extended oblique shock structure. A quadratic scaling of the pinch and stagnation conditions with the total current discharged between the electrodes is in qualitative agreement with the results obtained in the experiments. This also illustrates the dominant contribution of the magnetic pressure term in determining the magnitude of the quantities of interest.

  17. Semiconductor applications of plasma immersion ion implantation ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 25; Issue 6. Semiconductor applications of plasma immersion ion implantation technology ... Department of Electronic Science, Kurukshetra University, Kurukshetra 136 119, India ...

  18. Decreased Volume of the Cerebral Ventricles on CT Images in Gilles de la Tourette’s Syndrome

    Directory of Open Access Journals (Sweden)

    Lisbeth Regeur

    1999-01-01

    Full Text Available The aim of the present study was to estimate the volume of the ventricular system comprising lateral plus third ventricles in patients with Gilles de la Tourette's syndrome on computed tomographic (CT scannings using unbiased stereological principles and to compare that volume with a control group. We found a significantly reduced ventricular volume in 24 patients with Gilles de la Tourette's syndrome (GTS compared with 28 controls.

  19. The effects of aqueous extract of water cress on the glucose and lipid plasma in the streptozotocin induced diabetic rats

    International Nuclear Information System (INIS)

    Shahrokhi, N.; Hadad, K.

    2009-01-01

    For treating diabetic patients, different nutrients are being used in some areas of Kennan province, Nasturtium offsinallis (NF) is one of them. In current research work, effects of NF on plasma lipid and glucose levels have been assessed in diabetic rats. In this study, 60 male rats were used. All rats randomly divided into six groups, consisting of one intact non-diabetic group, and remaining 5 groups were injected subcutaneousloy of 55 mg/kg of streptozotocin to make them experimentally diabetic. Three groups of diabetic animals were eaten orally (via gavage) of low (25 mg/kg), and high (75 mg/kg) doses of aqueous extract of NF in a volume of 1.5 ml for short period (4 weeks)and long period (8-weeks) respectively. One group of diabetic animals was given 2-4U of NPH insulin intraperitoneally (IP). The last remaining group of five diabetics was given nothing at the end of each Experiment in all groups' blood glucose and lipid levels were measured. There was significant reduction of plasma glucose in treatment groups compared to diabetic group. The greatest decrease(9 6%) was observed by the high dose long term group for NF extract) that was significantly greater than the insulin group (49%) (p<0.001). There wasn't any change in diabetic animals' total cholesterol, and triglyceride levels of plasma. Both low and high doses of extracts increased LDL-cholesterol levels in diabetic animals (p<0.00 I). In diabetic animals, plasma H DL- cholesterol levels (33+-2.2) decreased by long term dose of extract. Both doses decreased plasma glucose in diabetic animal, whereas, it have not effect on plasma lipids or have negative effect, there fore this research suggested that NF extract is useful for control of blood glucose. (author)

  20. Magnetic stresses in ideal MHD plasmas

    DEFF Research Database (Denmark)

    Jensen, V.O.

    1995-01-01

    The concept of magnetic stresses in ideal MHD plasma theory is reviewed and revisited with the aim of demonstrating its advantages as a basis for calculating and understanding plasma equilibria. Expressions are derived for the various stresses that transmit forces in a magnetized plasma...... and it is shown that the resulting magnetic forces on a finite volume element can be obtained by integrating the magnetic stresses over the surface of the element. The concept is used to rederive and discuss the equilibrium conditions for axisymmetric toroidal plasmas, including the virial theorem...... and the Shafranov shift. The method had pedagogical merits as it simplifies the calculations, improves the physical understanding and facilitates an assessment of the approximations made in the calculations....

  1. Quantification of air plasma chemistry for surface disinfection

    International Nuclear Information System (INIS)

    Pavlovich, Matthew J; Clark, Douglas S; Graves, David B

    2014-01-01

    Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O 3 ) and nitrogen oxides (NO and NO 2 , or NO x ) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NO x mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications. (paper)

  2. Quantification of air plasma chemistry for surface disinfection

    Science.gov (United States)

    Pavlovich, Matthew J.; Clark, Douglas S.; Graves, David B.

    2014-12-01

    Atmospheric-pressure air plasmas, created by a variety of discharges, are promising sources of reactive species for the emerging field of plasma biotechnology because of their convenience and ability to operate at ambient conditions. One biological application of ambient-air plasma is microbial disinfection, and the ability of air plasmas to decontaminate both solid surfaces and liquid volumes has been thoroughly established in the literature. However, the mechanism of disinfection and which reactive species most strongly correlate with antimicrobial effects are still not well understood. We describe quantitative gas-phase measurements of plasma chemistry via infrared spectroscopy in confined volumes, focusing on air plasma generated via surface micro-discharge (SMD). Previously, it has been shown that gaseous chemistry is highly sensitive to operating conditions, and the measurements we describe here extend those findings. We quantify the gaseous concentrations of ozone (O3) and nitrogen oxides (NO and NO2, or NOx) throughout the established ‘regimes’ for SMD air plasma chemistry: the low-power, ozone-dominated mode; the high-power, nitrogen oxides-dominated mode; and the intermediate, unstable transition region. The results presented here are in good agreement with previously published experimental studies of aqueous chemistry and parameterized models of gaseous chemistry. The principal finding of the present study is the correlation of bacterial inactivation on dry surfaces with gaseous chemistry across these time and power regimes. Bacterial decontamination is most effective in ‘NOx mode’ and less effective in ‘ozone mode’, with the weakest antibacterial effects in the transition region. Our results underscore the dynamic nature of air plasma chemistry and the importance of careful chemical characterization of plasma devices intended for biological applications.

  3. High Throughput Plasma Water Treatment

    Science.gov (United States)

    Mujovic, Selman; Foster, John

    2016-10-01

    The troublesome emergence of new classes of micro-pollutants, such as pharmaceuticals and endocrine disruptors, poses challenges for conventional water treatment systems. In an effort to address these contaminants and to support water reuse in drought stricken regions, new technologies must be introduced. The interaction of water with plasma rapidly mineralizes organics by inducing advanced oxidation in addition to other chemical, physical and radiative processes. The primary barrier to the implementation of plasma-based water treatment is process volume scale up. In this work, we investigate a potentially scalable, high throughput plasma water reactor that utilizes a packed bed dielectric barrier-like geometry to maximize the plasma-water interface. Here, the water serves as the dielectric medium. High-speed imaging and emission spectroscopy are used to characterize the reactor discharges. Changes in methylene blue concentration and basic water parameters are mapped as a function of plasma treatment time. Experimental results are compared to electrostatic and plasma chemistry computations, which will provide insight into the reactor's operation so that efficiency can be assessed. Supported by NSF (CBET 1336375).

  4. PULSION registered HP: Tunable, High Productivity Plasma Doping

    International Nuclear Information System (INIS)

    Felch, S. B.; Torregrosa, F.; Etienne, H.; Spiegel, Y.; Roux, L.; Turnbaugh, D.

    2011-01-01

    Plasma doping has been explored for many implant applications for over two decades and is now being used in semiconductor manufacturing for two applications: DRAM polysilicon counter-doping and contact doping. The PULSION HP is a new plasma doping tool developed by Ion Beam Services for high-volume production that enables customer control of the dominant mechanism--deposition, implant, or etch. The key features of this tool are a proprietary, remote RF plasma source that enables a high density plasma with low chamber pressure, resulting in a wide process space, and special chamber and wafer electrode designs that optimize doping uniformity.

  5. Effect of 3-aminobenzamide, PARP inhibitor, on matrix metalloproteinase-9 level in plasma and brain of ischemic stroke model

    International Nuclear Information System (INIS)

    Koh, Seong-Ho; Chang, Dae-Il; Kim, Hee-Tae; Kim, Juhan; Kim, Myung-Ho; Kim, Kyung Suk; Bae, Inhee; Kim, Haekwon; Kim, Dong Won; Kim, Seung Hyun

    2005-01-01

    We investigated the effect of poly(ADP-ribose) polymerase (PARP) inhibitor on the levels of plasma and brain matrix metalloproteinase-9 (MMP-9) and the expression of nuclear factor kappa B (NF-κB) during experimental focal cerebral ischemia. The 3-aminobenzamide (3-AB), a PARP inhibitor, and saline were administered to 80 Sprague-Dawley rats [3-AB group; 5 rats for plasma sampling, 35 for brain sampling, and 40 for TTC staining] and to 85 rats (10, 35, and 40, respectively), respectively, 10 min before the occlusion of the left middle cerebral artery (MCAo) for 2 h. Infarct volume was measured by TTC staining, the serial levels of plasma and brain MMP-9 were measured by zymography just before and 2, 4, 8, 24, 48, and 72 h after MCAo, brain NF-κB activity was determined by Western blotting, and neutrophil infiltration was evaluated by assessing myeloperoxidase activity. Compared with control group, the levels of plasma and brain MMP-9, brain NF-κB, and MPO activities were significantly reduced in 3-AB group at each time point (p < 0.05). Plasma MMP-9 increased maximally at 4 h and then decreased rapidly, brain MMP-9 increased maximally at 24 h and persisted until 72 h, and NF-κB increased maximally at 24 h and then decreased slowly in both groups. Therefore, the PARP inhibitor reduces the expression of MMP-9 and NF-κB and the infiltration of neutrophils in ischemic stroke

  6. Placed in a steady magnetic field, the flux density inside a permalloy-shielded volume decreases over hours and days

    Science.gov (United States)

    Feinberg, Benedict; Gould, Harvey

    2018-03-01

    Following the application of an external magnetic field to a thin-walled demagnetized Permalloy cylinder, the magnetic flux density at the center of the shielded volume decreases by roughly 20% over periods of hours to days. We measured this effect for applied magnetic fields from 0.48 A/m to 16 A/m, the latter being comparable to the Earths magnetic field at its weakest point. Delayed changes in magnetic flux density are also observed following alternating current demagnetization. We attribute these effects to delayed changes in magnetization, which have previously been observed in thin Permalloy films and small bulk samples of ferromagnetic materials. Phenomenological models of thermal activation are discussed. Some possible effects on experiments that rely on static shielding are noted.

  7. Evaluation of plasma chemistry and haematological studies on chickens infected with Eimeria tenella and E acervulina.

    Science.gov (United States)

    Fukata, T; Komba, Y; Sasai, K; Baba, E; Arakawa, A

    1997-07-12

    Plasma chemistry and haematological studies were conducted on chickens with coccidiosis. Male White Leghorn chickens, of two weeks old, were inoculated with 5 x 10(4) Eimeria tenella sporulated oocysts or with 1 x 10(6) E acervulina sporulated oocysts. Blood samples were taken four, seven and 11 days after inoculation. A wet chemistry system was applied to measure the plasma activities of aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, gamma glutamyltransferase, creatine kinase, amylase and lactate dehydrogenase and the concentrations of creatine, total bilirubin, urate, total cholesterol, total protein, albumin, glucose and triglycerides. A dry chemistry system was applied to measure sodium, potassium, chloride and calcium. The number of red blood cells and packed cell volume were determined by a micro cell counter and blood pH was measured with a blood gas analyser. The erythrocyte count, packed cell volume, sodium and chloride levels in the chickens infected with E tenella were significantly (P < 0.05) lower than those of the uninfected controls. The significant decrease in blood pH of the chickens infected with E acervulina suggests malabsorption associated with duodenal lesions induced by the infection.

  8. Humoral Na+-K+ pump inhibitory activity in essential hypertension and in normotensive subjects after acute volume expansion

    International Nuclear Information System (INIS)

    Pamnani, M.B.; Burris, J.F.; Jemionek, J.F.; Huot, S.J.; Price, M.; Freis, E.D.; Haddy, F.J.

    1989-01-01

    Plasma from black male patients with essential hypertension was bioassayed for vascular Na+-K+ pump inhibitory activity. Halves of the same rat tail artery were incubated for two hours in boiled plasma supernates from a hypertensive patient and a paired age-, sex-, and race-matched normotensive subject and then ouabain-sensitive 86 Rb uptake was measured. Ouabain-sensitive 86 Rb uptake by their leukocytes was also measured. Eighteen pairs of subjects were studied. The uptakes were not significantly different in the hypertensive patients and control subjects. However, when we selected from the eighteen hypertensive patients, nine with low plasma renin activity on the day of the study, uptakes were reduced in the hypertensive patients relative to the paired control subjects. We also assayed plasma supernates from normotensive black and white male subjects before and after acute volume expansion (2.5 L saline IV + 1.5 L distilled water orally over a three-hour period) and from paired normotensive subjects before and after sham volume expansion and obtained a positive bioassay in the expanded subjects both on intraindividual and interindividual comparisons. These studies demonstrate increased vascular Na+-K+ pump inhibitory activity in the plasma of black male patients with low renin essential hypertension and in the plasma of normotensive subjects after acute volume expansion. The findings suggest that the inhibitory activity in the hypertensive subjects' plasma is related to volume expansion, relative or absolute

  9. Measurement of effective renal plasma flow in congestive heart failure

    International Nuclear Information System (INIS)

    Tauxe, W.N.; Dubovsky, E.V.; Mantle, J.A.; Dustan, H.P.; Logic, J.R.

    1981-01-01

    In the management of patients with congestive heart failure (CHF), it is often desirable to have precise knowledge of overall renal function, including the effective renal plasma flow (ERPF). It has long been recognized that ERPF is diminished in CHF. Since glomerular filtration rate is often decreased to a much lesser extent, other noninvasive procedures such as the measurement of creatinine clearances may not be entirely suitable. ERPF determination by the single plasma sampling (SPS) method affords a rapid, simple, noninvasive, and economical technique that is quite accurate and reproducible. A SPS method has been well-tested in patients following renal transplantation plus a wide variety of nephrological disorders. We have been concerned whether the SPS method would be valid in volume expanded patients. In 28 determinations of ERPF in patients with CHF, and in five patients who did not have CHF, we have found the SPS estimation of ERPF to yield results that are not clinically significantly different from those obtained by the detailed compartmental analysis method. The volumes of 131 I-orthoiodohippurate (OIH) distribution were found to be somewhat higher in CHF than in controls, but fractional rate constants were proportionately lower so that intercompartmental flow rates and OIH concentrations were not different from controls. Therefore, the SPS estimation of ERPF is valid in patients with CHF and may be useful in monitoring the renal effects of various hemodynamic and pharmacological interventions. (orig.)

  10. Decreased mean platelet volume in panic disorder

    Directory of Open Access Journals (Sweden)

    Göğçegöz Gül I

    2014-09-01

    Full Text Available Işil Göğçegöz Gül, Gül Eryilmaz, Eylem Özten, Gökben Hizli Sayar Neuropsychiatry Health, Practice, and Research Center, Uskudar University, Istanbul, Turkey Aim: The relationship between psychological stress and platelet activation has been widely studied. It is well known that platelets may reflect certain biochemical changes that occur in the brain when different mental conditions occur. Platelet 5-hydroxytryptamine (5-HT is also extensively studied in psychiatry. The mean platelet volume (MPV, the accurate measure of platelet size, has been considered a marker and determinant of platelet function. The aim of the present study was to search for any probable difference in the MPV of subjects with panic disorder (PD.Methods: A total of 37 drug-free subjects, aged 18 to 65 years, diagnosed with PD, with or without agoraphobia, according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth edition (DSM-IV criteria and 45 healthy control subjects were included in the study. Platelet count and MPV were measured and recorded for each subject.Results: There were no statistically significant differences between groups in terms of female/male ratio, age, or body mass index between the PD group and control group (P=0.91, P=0.82, and P=0.93, respectively. The MPV was found to be significantly lower in the PD group compared with the control group (8.8±0.9 fL vs 9.2±0.8 fL; P=0.02. All the participants had MPV values in the standard range of 6.9–10.8 fL.Conclusion: We concluded that abnormalities of the 5-HT1A receptor function in the central nervous system of subjects with a diagnosis of PD are also mirrored in as an alteration in platelet activity. Measurements of platelet activity may be used as a tool for neuropsychiatric and psychopharmacological research and for studying how certain mental diseases and medications affect the central nervous system. Keywords: 5-HT, thrombocyte, anxiety 

  11. Higher plasma motilin levels in obese patients decrease after Roux-en-Y gastric bypass surgery and regulate hunger.

    Science.gov (United States)

    Deloose, E; Janssen, P; Lannoo, M; Van der Schueren, B; Depoortere, I; Tack, J

    2016-07-01

    Motilin-induced phase III contractions of the migrating motor complex (MMC) signal hunger in healthy volunteers. The current aim was to study the role of motilin as a hunger-inducing factor in obese patients and to evaluate the effect of Roux-en-Y gastric bypass (RYGB) surgery on plasma motilin levels and hunger scores. Motilin and ghrelin plasma levels were determined during a complete MMC cycle in controls and obese patients selected for RYGB before, 6 months and 1 year after surgery. 20 min after the end of the second phase III, obese patients received an intravenous infusion of 40 mg erythromycin. Hunger was scored every 5 min. Hedonic hunger was assessed in obese patients with the Power of Food Scale questionnaire. Obesity caused a switch in the origin of phase III from antrum to duodenum. Obese patients had significantly higher motilin levels compared with controls during the MMC but tended to lack the motilin peak prior to phase III necessary to trigger hunger. Hunger scores during phase III were significantly lower in obese patients, but could be restored to control levels through the administration of a low dose of the motilin agonist, erythromycin. After RYGB surgery motilin, but not ghrelin, levels decreased in parallel with hedonic hunger scores. Motilin may be an important regulator involved in the pathogenesis of obesity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Thermal stability of a thermonuclear plasma for different confinement scaling laws

    International Nuclear Information System (INIS)

    Johner, J.

    1985-10-01

    The thermal stability of the ignition curve is investigated using a simple OD model for a temperature dependent energy confinement time (tausub(E) is proportional to 1/Tsup(γ)). The stability limit in the (ntausub(E),T) plane is also calculated for a plasma with external heating. The degradation of confinement time with increasing temperature is found to be favourable for divergence temperature and minimum temperature for stable ignition. It also decreases the external power per unit volume necessary to reach divergence. On the contrary, it is extremely unfavourable for the required μsub(E) for divergence and ignition. Detailed results are given for the special case of the Kaye-Goldston scaling (γ=1.38)

  13. Effects of foreign gases on H- formation in a magnetic multipole hydrogen plasma source

    International Nuclear Information System (INIS)

    Mosbach, T

    2005-01-01

    The effects of admixtures of argon and xenon and of nitrogen (for the purpose of comparison between atomic and molecular additives) to a given H 2 base pressure are investigated with respect to the vibrational populations of hydrogen molecules in the electronic ground state, to the density of negative ions and to the electron energy distribution function (EEDF). This work aims to unravel the influence of the vibrational population distribution and the EEDF on the formation of negative hydrogen ions in the volume of a magnetic multipole plasma source. The admixtures of these foreign gases lead to a measurable state-specific decrease in the population of the high vibrational states of the H 2 molecule. Higher states exhibit a clearly stronger decrease with increasing foreign gas partial pressure. The measured density of the negative ions decreases with increasing noble gas partial pressure, despite the fact that the low-energy fraction of the measured EEDF is modified such that the efficiency of ion formation by dissociative attachment is more favourable. The various measurements are compared for the case of the H 2 -Ar discharge, with a global model developed for the stationary plasma state. The decrease in the density of the negative ions with increasing argon admixture can be reproduced by the model with high accuracy on the basis of measured population distributions of the vibrationally excited H 2 molecules and the measured EEDF

  14. Comparison of Hippocampal Volume in Dementia Subtypes

    International Nuclear Information System (INIS)

    Vijayakumar, Avinash; Vijayakumar, Abhishek

    2012-01-01

    Aims. To examine the relationship between different types of dementia and hippocampal volume. Methods. Hippocampal volume was measured using FL3D sequence magnetic resonance imaging in 26 Alzheimer's, vascular dementia, mixed dementia, and normal pressure hydrocephalus patients and 15 healthy controls and also hippocampal ratio, analyzed. Minimental scale was used to stratify patients on cognitive function impairments. Results. Hippocampal volume and ratio was reduced by 25% in Alzheimer's disease, 21% in mixed dementia, 11% in vascular dementia and 5% in normal pressure hydrocephalus in comparison to control. Also an asymmetrical decrease in volume of left hippocampus was noted. The severity of dementia increased in accordance to decreasing hippocampal volume. Conclusion. Measurement in hippocampal volume may facilitate in differentiating different types of dementia and in disease progression. There was a correlation between hippocampal volume and severity of cognitive impairment

  15. Plasma-neutral gas interaction in a tokamak divertor: effects of hydrogen molecules and plasma recombination

    International Nuclear Information System (INIS)

    Krasheninnikov, S.I.; Pigarov, A.Yu.; Soboleva, T.K.; Sigmar, D.J.

    1997-01-01

    We investigate the influence of hydrogen molecules on plasma recombination using a collisional-radiative model for multispecies hydrogen plasmas and tokamak detached divertor parameters. The rate constant found for molecular activated recombination of a plasma can be as high as 2 x 10 -10 cm 3 /s, confirming our pervious estimates. We investigate the effects of hydrogen molecules and plasma recombination on self-consistent plasma-neutral gas interactions in the recycling region of a tokamak divertor. We treat the plasma flow in a fluid approximation retaining the effects of plasma recombination and employing a Knudsen neutral transport model for a 'gas box' divertor geometry. For the model of plasma-neutral interactions we employ we find: (a) molecular activated recombination is a dominant channel of divertor plasma recombination; and (b) plasma recombination is a key element leading to a decrease in the plasma flux onto the target and substantial plasma pressure drop which are the main features of detached divertor regimes. (orig.)

  16. Atomic and plasma-material interaction data for fusion. V. 7, part B. Particle induced erosion of Be, C and W in fusion plasmas. Part B: Physical sputtering and radiation-enhanced sublimation

    International Nuclear Information System (INIS)

    Eckstein, W.; Stephens, J.A.; Clark, R.E.H.; Davis, J.W.; Haasz, A.A.; Vietzke, E.; Hirooka, Y.

    2001-01-01

    The present volume of Atomic and Plasma-Material Interaction Data for Fusion is devoted to a critical review of the physical sputtering and radiation enhanced sublimation (RES) behaviour of fusion plasma-facing materials, in particular carbon, beryllium and tungsten. The present volume is intended to provide fusion reactor designers a detailed survey and parameterization of existing, critically assessed data for the chemical erosion of plasma-facing materials by particle impact. The survey and data compilation is presented for a variety of materials containing the elements C, Be and W (including dopants in carbon materials) and impacting plasma species. The dependencies of physical sputtering and RES yields on the material temperature, incident projectile energy, and incident flux are considered. The main data compilation is presented as separate data sheets indicating the material, impacting plasma species, experimental conditions, and parameterizations in terms of analytic functions

  17. Sheath and bulk expansion induced by RF bias in atmospheric pressure microwave plasma

    Science.gov (United States)

    Lee, Jimo; Nam, Woojin; Lee, Jae Koo; Yun, Gunsu

    2017-10-01

    A large axial volume expansion of microwave-driven plasma at atmospheric pressure is achieved by applying a low power radio frequency (RF) bias at an axial location well isolated from the original plasma bulk. The evolution of the plasma plume visualized by high speed ICCD imaging suggest that the free electrons drifting toward the bias electrode cause the prodigious expansion of the sheath, creating a stable plasma stream channel between the microwave and the RF electrodes. For argon plasma in ambient air, enhanced emissions of OH and N2 spectral lines are measured in the extended plume region, supporting the acceleration of electrons and subsequent generation of radical species. The coupling of RF bias with microwave provides an efficient way of enlarging the plasma volume and enhancing the production of radicals. Work supported by the National Research Foundation of Korea under BK21+ program and Grant No. 2015R1D1A1A01061556 (Ministry of Education).

  18. EDITORIAL: 80 Years of Plasma 80 Years of Plasma

    Science.gov (United States)

    Franklin, R. N.; Braithwaite, N. St J.

    2009-02-01

    to admission to Columbia University where he studied metallurgical engineering. After graduation, as was common at that time for able students, he was encouraged to go abroad for his doctoral work. He went to Göttingen, which was then one of the leading European universities in science, and studied under Nernst. Returning to the United States he obtained a post as a teaching assistant at the Stevens Institute of Technology, Hoboken, but the atmosphere proved too hierarchical and uncongenial for a scientist who was wanting to spread his wings. Fortunately the General Electric Company (GEC) recognized his potential; he was recruited in 1909, and remained associated with the GEC for the next 48 years. He quickly established his credentials as a research scientist and was soon given the freedom to pursue his interests wherever they took him, consistent with the overall strategy of the company. His appointment as an Associate Director at the GEC came in the same year that he introduced the term 'plasma'. Interestingly, while the term gained rapid acceptance in Europe, the associated word 'sheath', which Langmuir had already been using for several years, was translated into French, German and Russian and suffered from confusion. That confusion was there in Langmuir's writings because this ion-rich region sometimes was a region with barely any electrons and sometimes it contained a significant quantity of negative charge. The structure of the plasma-sheath and its elucidation had to await new mathematical techniques and the impact of computers as evidenced by papers in this volume and those quoted therein. It is clear that Langmuir inspired and benefited from collaboration with co-workers at the GEC, notably Kingdon, Taylor, Mott-Smith, Compton, Jones, Found, Tonks and Blodgett. In several ways he was ahead of his time in his understanding of gas discharges, and a particular example is what has since come to be known as the Bohm criterion. More than once in his plasma

  19. Decreased plasma levels of factor II + VII + X correlate with increased levels of soluble cytokine receptors in patients with malaria and meningococcal infections

    DEFF Research Database (Denmark)

    Bygbjerg, I C; Hansen, M B; Rønn, A M

    1997-01-01

    The levels of coagulation factors II + VII + X and of blood platelets (thrombocytes) as well as of cytokines and soluble cytokine receptors were studied in the patients with malaria or meningococcal infections. The coagulation factors were decreased particularly in the meningococcal patients, while...... thrombocytes were lowest in the Plasmodium falciparum malaria patients. There was no correlation between factors II + VII + X and thrombocytes, but plasma levels of coagulation factors II + VII + X were found to correlate inversely with levels of soluble interleukin-2 receptor (sIL-2R) and soluble tumour...... necrosis factor-I (sTNF-RI) in patients with malaria and meningococcal infections. Elevated sIL-2R and sTNF-RI levels and decreased coagulation factors reverted to normal within 3-5 days after initiation of therapy in P. falciparum patients followed consecutively. Estimation of coagulation factors may...

  20. High-volume plasma exchange in patients with acute liver failure: An open randomised controlled trial.

    Science.gov (United States)

    Larsen, Fin Stolze; Schmidt, Lars Ebbe; Bernsmeier, Christine; Rasmussen, Allan; Isoniemi, Helena; Patel, Vishal C; Triantafyllou, Evangelos; Bernal, William; Auzinger, Georg; Shawcross, Debbie; Eefsen, Martin; Bjerring, Peter Nissen; Clemmesen, Jens Otto; Hockerstedt, Krister; Frederiksen, Hans-Jørgen; Hansen, Bent Adel; Antoniades, Charalambos G; Wendon, Julia

    2016-01-01

    Acute liver failure (ALF) often results in cardiovascular instability, renal failure, brain oedema and death either due to irreversible shock, cerebral herniation or development of multiple organ failure. High-volume plasma exchange (HVP), defined as exchange of 8-12 or 15% of ideal body weight with fresh frozen plasma in case series improves systemic, cerebral and splanchnic parameters. In this prospective, randomised, controlled, multicentre trial we randomly assigned 182 patients with ALF to receive either standard medical therapy (SMT; 90 patients) or SMT plus HVP for three days (92 patients). The baseline characteristics of the groups were similar. The primary endpoint was liver transplantation-free survival during hospital stay. Secondary-endpoints included survival after liver transplantation with or without HVP with intention-to-treat analysis. A proof-of-principle study evaluating the effect of HVP on the immune cell function was also undertaken. For the entire patient population, overall hospital survival was 58.7% for patients treated with HVP vs. 47.8% for the control group (hazard ratio (HR), with stratification for liver transplantation: 0.56; 95% confidence interval (CI), 0.36-0.86; p=0.0083). HVP prior to transplantation did not improve survival compared with patients who received SMT alone (CI 0.37 to 3.98; p=0.75). The incidence of severe adverse events was similar in the two groups. Systemic inflammatory response syndrome (SIRS) and sequential organ failure assessment (SOFA) scores fell in the treated group compared to control group, over the study period (pHVP improves outcome in patients with ALF by increasing liver transplant-free survival. This is attributable to attenuation of innate immune activation and amelioration of multi-organ dysfunction. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  1. Progress report on nuclear science and technology in China (Vol.3). Proceedings of academic annual meeting of China Nuclear Society in 2013, No.7--nuclear fusion and plasma physics sub-volume

    International Nuclear Information System (INIS)

    2014-05-01

    Progress report on nuclear science and technology in China (Vol. 3) includes 22 articles which are communicated on the third national academic annual meeting of China Nuclear Society. There are 10 books totally. This is the seventh one, the content is about nuclear fusion and plasma physics sub-volume

  2. Peroxisome Proliferator-Activated Receptor-α Activation Decreases Mean Arterial Pressure, Plasma Interleukin-6, and COX-2 While Increasing Renal CYP4A Expression in an Acute Model of DOCA-Salt Hypertension

    Directory of Open Access Journals (Sweden)

    Dexter L. Lee

    2011-01-01

    Full Text Available Peroxisome proliferator-activated receptor-alpha (PPAR-α activation by fenofibrate reduces blood pressure and sodium retention during DOCA-salt hypertension. PPAR-α activation reduces the expression of inflammatory cytokines, such as interleukin-6 (IL-6. Fenofibrate also induces cytochrome P450 4A (CYP4A and increases 20-hydroxyeicosatetraenoic acid (20-HETE production. This study tested whether the administration of fenofibrate would reduce blood pressure by attenuating plasma IL-6 and renal expression of cyclooxygenase-2 (COX-2, while increasing expression of renal CYP4A during 7 days of DOCA-salt hypertension. We performed uni-nephrectomy on 12–14 week old male Swiss Webster mice and implanted biotelemetry devices in control, DOCA-salt (1.5 mg/g treated mice with or without fenofibrate (500 mg/kg/day in corn oil, intragastrically. Fenofibrate significantly decreased mean arterial pressure and plasma IL-6. In kidney homogenates, fenofibrate increased CYP4A and decreased COX-2 expression. There were no differences in renal cytochrome P450, family 2, subfamily c, polypeptide 23 (CYP2C23 and soluble expoxide hydrolase (sEH expression between the groups. Our results suggest that the blood pressure lowering effect of PPAR-α activation by fenofibrate involves the reduction of plasma IL-6 and COX-2, while increasing CYP4A expression during DOCA-salt hypertension. Our results may also suggest that PPAR-α activation protects the kidney against renal injury via decreased COX-2 expression.

  3. A plasma melting of noncombustible waste for vitrification

    International Nuclear Information System (INIS)

    Moon, Young Pyo; Cho, Chun Hyung; Song, Myung Jae; Han, Sang Ok

    1997-01-01

    Multi-stage experiments have been under way to develop a new technology for radioactive waste treatment to reduce volume. Korea Electric Power Research Institute(KEPRI) has been seeking various technologies in order to reduce the radioactive volume significantly and to produce very stable waste forms. Plasma melting technology which offers greater control of temperature, faster time of reaction, better control of processing, lower capital costs, greater throughput, and more efficient use of energy has caught KEPRI's attention to the noncombustible radioactive waste. For the study of plasma melting for noncombustible wastes, KEPRI leased a lab scale multi-purpose plasma furnace together with accessory facilities and performed preliminary tests. The lab scale melting experiments were carried out by using the simulated noncombustible wastes based on the field survey data from nuclear power plants. KEPRI's current study is focused to find an optimum composition ratio of various noncombustible wastes for easy melting, to investigate physical properties of molten slag, and to obtain operating parameters for continuous operations

  4. Effect of ionic and non-ionic contrast media on whole blood viscosity, plasma viscosity and hematocrit in vitro

    International Nuclear Information System (INIS)

    Aspelin, P.

    1978-01-01

    The effect of the ionic contrast media diatrizoate, iocarmate and metrizoate and the non-ionic metrizamide on whole blood viscosity, plasma viscosity and hematocrit was investigated. All the contrast media increased whole blood and plasma viscosity and reduced the hematocrit. The whole blood viscosity increased with increasing osmolality of the contrast medium solutions, whereas the plasma viscosity increased with increasing viscosity of the contrast medium solutions. The higher the osmolality of the contrast media, the lower the hematocrit became. The normal shear-thinning (decreasing viscosity with increasing shear rate) property of blood was reduced when contrast medium was added to the blood. At 50 per cent volume ratio (contrast medium to blood), the ionic contrast media converted the blood into a shear-thickening (increasing viscosity with increasing shear rate) suspension, indicating a marked rigidification of the single red cell, while the non-ionic contrast medium still produced shear-thinning, indicating less rigidification of the red cell (p<0.01). (Auth.)

  5. Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.

    Science.gov (United States)

    Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie

    2014-11-01

    Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Atomic and Plasma-Material Interaction Data for Fusion. V. 16

    International Nuclear Information System (INIS)

    Braams, B.J.; Chung, H.-K.

    2014-03-01

    A wide variety of atomic, molecular, radiative and plasma-wall interaction processes involving a mixture of atoms, ions and molecules occur in the plasmas produced in nuclear fusion experiments. In the low temperature divertor and near wall region, molecules and molecular ions are formed. The plasma particles react with electrons and with each other. Plasma modelling requires cross-sections and rate coefficients for all these processes, and in addition spectral signatures to support interpretation of data from fusion experiments. The mission of the International Atomic Energy Agency Nuclear Data Section (IAEA/NDS) in the area of atomic and molecular data is to enhance the competencies of Member States in their research into nuclear fusion through the provision of internationally recommended atomic, molecular, plasma-material interaction and material properties databases. One mechanism by which the IAEA pursues this mission is the Coordinated Research Project (CRP). The present volume of Atomic and Plasma-Material Interaction Data for Fusion contains contributions from participants in the CRP 'Atomic and Molecular Data for Plasma Modelling' (2004-2008). This CRP was concerned with data for processes in the near wall and divertor plasma and plasma-wall interaction in fusion experiments, with focus on cross-sections for molecular reactions. Participants in the CRP came from 14 different institutes, many with strong ties to fusion plasma modelling and experiment. D. Humbert of the Nuclear Data Section was scientific secretary of the CRP. Participants' contributions for this volume were collected and refereed after the conclusion of the CRP

  7. Collective phenomena in volume and surface barrier discharges

    Science.gov (United States)

    Kogelschatz, U.

    2010-11-01

    Barrier discharges are increasingly used as a cost-effective configuration to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without significant heating of the background gas. In most applications the barrier is made of dielectric material. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are devoted to biomedical applications and to plasma actuators for flow control. Sinusoidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or diffuse, laterally homogeneous discharges. The physical effects leading to collective phenomena in volume and surface barrier discharges are discussed in detail. Special attention is paid to self-organization of current filaments and pattern formation. Major similarities of the two types of barrier discharges are elaborated.

  8. Plasma exchange in the intensive care unit: Technical aspects and complications.

    Science.gov (United States)

    Lemaire, Aurélie; Parquet, Nathalie; Galicier, Lionel; Boutboul, David; Bertinchamp, Rémi; Malphettes, Marion; Dumas, Guillaume; Mariotte, Eric; Peraldi, Marie-Noëlle; Souppart, Virginie; Schlemmer, Benoit; Azoulay, Elie; Canet, Emmanuel

    2017-12-01

    Data on plasma exchange therapy in the intensive care unit (ICU) setting are scarce. We aimed to describe the technical aspects and the adverse events associated with the procedure in critically ill patients. All adult patients treated by plasma exchange in the medical ICU of the Saint-Louis university hospital between January 1, 2013 and March 31, 2015 were prospectively included. We report on 260 plasma exchange procedures performed in 50 patients. The centrifugation technique was used for 159 (61%) procedures and the filtration technique for the other 101 (39%) procedures. Both techniques had similar efficacy to treat hyperviscosity syndrome (n = 18). Seventy (26.9%) of the 260 plasma exchange procedures were reported with at least one adverse reaction. Centrifugation and filtration techniques had similar rates of adverse reactions (23.9 vs. 31.7%, P = .19). Hypotension was the most reported (n = 21, 8%) and correlates with a low hematocrit before therapy. Most complications were related to allergic reactions to the replacement fluids. Coagulation disorders depended on the type of replacement fluid. The post-exchange fibrinogen level was decreased by 54% [48;66] with albumin 5%, and 4% [-5;17] with plasma frozen within 24 h. Twenty-three (22.8%) of the 101 filtration procedures experienced filter clotting. Filter clotting was associated with a higher volume exchange prescribed when compared to procedures without filter clotting (4600 [4000;5000] ml vs. 3900 [3600;4800] ml, P < .01). Plasma exchange is a relatively safe and generally well-tolerated procedure in the ICU setting. Most adverse events are unpredictable and related to minor allergic reactions. © 2017 Wiley Periodicals, Inc.

  9. Atomic and plasma-material interaction data for fusion. V. 3

    International Nuclear Information System (INIS)

    1992-01-01

    This volume of Atomic and Plasma-Material Interaction Data for Fusion is devoted to atomic collision processes of helium atoms and of beryllium and boron atoms and ions in fusion plasmas. Most of the articles included in this volume are extended versions of the contributions presented at the IAEA experts' meetings on Atomic Data for Helium Beam Fusion Alpha Particle Diagnostics and on the Atomic Database for Beryllium and Boron, held in June 1991 at the IAEA headquarters in Vienna, or have resulted from the cross-section data analyses and evaluations performed by the working groups of these meetings. Refs, figs and tabs

  10. Spheroidization by Plasma Processing and Characterization of Stainless Steel Powder for 3D Printing

    Science.gov (United States)

    Ji, Lina; Wang, Changzhen; Wu, Wenjie; Tan, Chao; Wang, Guoyu; Duan, Xuan-Ming

    2017-10-01

    Stainless steel 316L (SS 316L) powder was spheroidized by plasma processing to improve its suitability for powder 3D printing. The obtained spheroidized (sphero) powder was characterized in terms of its crystalline phases, elemental composition, morphology, particle size and distribution, light absorption, and flow properties. The elemental composition of the sphero powder met the Chinese standard for SS 316L except for its Si content. The volume fraction of ferrite increased after plasma processing. Furthermore, plasma processing was shown to not only reduce the mean size of the particles in the size range of 10 to 100 μm but also generate particles in the size range of 0.1 to 10 μm. The smaller particles filled the voids among larger particles, increasing the powder density. The light absorption was also increased owing to enhanced internal reflection. Although the basic flow energy decreased after plasma processing, the flow function (FF) value was smaller for the sphero powder, indicating a lower flowability of the sphero powder. However, the density of SS 316L pieces printed with commercial and sphero powders was 98.76 pct and 98.16 pct of the SS 316L bulk density, respectively, indicating the suitability of the sphero powder for 3D printing despite an FF below 10.

  11. Plasma trace metals during total parenteral alimentation.

    Science.gov (United States)

    Solomons, N W; Layden, T J; Rosenberg, I H; Vo-Khactu, K; Sandstead, H H

    1976-06-01

    The plasma concentrations of the trace metals zinc and copper were studied prospectively in 13 patients with gastrointestinal diseases treated with parenteral alimentation (TPA) for periods of from 8 days to 7 1/2 weeks. Plasma copper levels fell rapidly and consistently in all patients, with an overall rate of - 11 mug per 100 ml per week. Zinc concentrations declined in 10 of 13 patients at a more gradual rate. Analysis of the standard parenteral alimentation fluids revealed zinc content equivalent to 50% of the daily requirement and a negligible content of copper. From combined analysis of plasma zinc, hair zinc, and taste acuity, there is evidence that increased utilization or redistribution within the body may effect plasma concentrations in some patients. Neither an increase in urinary excretion nor a primary decrease in plasma binding proteins appeared to be a major factor in lowering plasma trace metal concentrations. These findings indicate that a marked decrease in plasma copper is regular and a decline in plasma zinc is common during TPA using fluids unsupplemented with trace metals. Supplementation of parenteral alimentation fluids with the trace metals zinc and copper is recommended.

  12. Preparation and Performance of Plasma/Polymer Composite Coatings on Magnesium Alloy

    DEFF Research Database (Denmark)

    Bakhsheshi-Rad, H. R.; Hamzah, E.; Bagheriyan, S.

    2016-01-01

    ) that homogeneously covered the surface of the plasma layers. Contact angle measurement showed that polymer coating over plasma layers significantly decreased surface wettability. The corrosion current density (icorr) of an uncoated sample (262.7 µA/cm2) decreased to 76.9 µA/cm2 after plasma coatings were applied...

  13. Comprehensive Study of Plasma-Wall Sheath Transport Phenomena

    Science.gov (United States)

    2016-10-26

    the floating potential of wall material samples immersed in a low-temperature plasma were studied. Hysteresis is found to be due to secondary electron...continued research into plasma sheath physics. Hysteresis effects observed in the floating potential of wall material samples immersed in a low... Journal of Applied Physics, Volume 119, March 2016, pp. 113305 1-5. DISTRIBUTION A: Distribution approved for public release. 8 Figure 2

  14. Recombination of a fast expanding plasma

    International Nuclear Information System (INIS)

    Salvat, M.

    1979-05-01

    The goal of the following calculations is to determine numerically the recombination of dense plasmas (for instance of laser-produced plasmas). The recombination is computed for plasmas with initial densities of 10 24 27 [m -3 ] and with initial temperatures >= 50 eV. The ionization of the plasma remains essentially constant during the early phase of expansion. The time for which the ionization is 'frozen-in' grows with decreasing initial density and with increasing initial temperature. (orig.) [de

  15. Sixteen-Day Bedrest Significantly Increases Plasma Colloid Osmotic Pressure

    Science.gov (United States)

    Hargens, Alan R.; Hsieh, S. T.; Murthy, G.; Ballard, R. E.; Convertino, V. A.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    Upon exposure to microgravity, astronauts lose up to 10% of their total plasma volume, which may contribute to orthostatic intolerance after space flight. Because plasma colloid osmotic pressure (COP) is a primary factor maintaining plasma volume, our objective was to measure time course changes in COP during microgravity simulated by 6 deg. head-down tilt (HDT). Seven healthy male subjects (30-55 years of age) were placed in HDT for 16 days. For the purpose of another study, three of the seven subjects were chosen to exercise on a cycle ergometer on day 16. Blood samples were drawn immediately before bedrest on day 14 of bedrest, 18-24 hours following exercise while all subjects were still in HDT and 1 hour following bedrest termination. Plasma COP was measured in all 20 microliter EDTA-treated samples using an osmometer fitted with a PM 30 membrane. Data were analyzed with paired and unpaired t-tests. Plasma COP on day 14 of bedrest (29.9 +/- 0.69 mmHg) was significantly higher (p less than 0.005) than the control, pre-bedrest value (23.1 +/- 0.76 mmHg). At one hour of upright recovery after HDT, plasma COP remained significantly elevated (exercise: 26.9 +/- 0.87 mmHg; no exercise: 26.3 +/- 0.85 mmHg). Additionally, exercise had no significant effect on plasma COP 18-24 hours following exercise (exercise: 27.8 +/- 1.09 mmHg; no exercise: 27.1 +/- 0.78 mmHg). Our results demonstrate that plasma COP increases significantly with microgravity simulated by HDT. However, preliminary results indicate exercise during HDT does not significantly affect plasma COP.

  16. Fourth Latin-American workshop on plasma physics. Contributed papers

    International Nuclear Information System (INIS)

    1990-01-01

    The main goal of this series of Workshops is to provide a periodic meeting place for Latin-American researchers in plasma physics together with colleagues from other countries around the world. This volume includes the contributed papers presented at the Workshop on Plasma Physics held in Buenos Aires in 1990. The scope of the Workshop can be synthesized in the following main subjects: Tokamak experiments and theory; alternative confinement systems and basic experiments; technology and applications; general theory; astrophysical and space plasmas

  17. Development of very large helicon plasma source

    International Nuclear Information System (INIS)

    Shinohara, Shunjiro; Tanikawa, Takao

    2004-01-01

    We have developed a very large volume, high-density helicon plasma source, 75 cm in diameter and 486 cm in axial length; full width at half maximum of the plasma density is up to ∼42 cm with good plasma uniformity along the z axis. By the use of a spiral antenna located just outside the end of the vacuum chamber through a quartz-glass window, plasma can be initiated with a very low value of radio frequency (rf) power ( 12 cm -3 is successfully produced with less than several hundred Watt; achieving excellent discharge efficiency. It is possible to control the radial density profile in this device by changing the magnetic field configurations near the antenna and/or the antenna radiation-field patterns

  18. A simple high-performance liquid chromatography for the determination of linezolid in human plasma and saliva.

    Science.gov (United States)

    Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi

    2015-09-01

    Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.

  19. A new multi-line cusp magnetic field plasma device (MPD) with variable magnetic field

    Science.gov (United States)

    Patel, A. D.; Sharma, M.; Ramasubramanian, N.; Ganesh, R.; Chattopadhyay, P. K.

    2018-04-01

    A new multi-line cusp magnetic field plasma device consisting of electromagnets with core material has been constructed with a capability to experimentally control the relative volume fractions of magnetized to unmagnetized plasma volume as well as accurate control on the gradient length scales of mean density and temperature profiles. Argon plasma has been produced using a hot tungsten cathode over a wide range of pressures 5 × 10-5 -1 × 10-3 mbar, achieving plasma densities ranging from 109 to 1011 cm-3 and the electron temperature in the range 1-8 eV. The radial profiles of plasma parameters measured along the non-cusp region (in between two consecutive magnets) show a finite region with uniform and quiescent plasma, where the magnetic field is very low such that the ions are unmagnetized. Beyond that region, both plasma species are magnetized and the profiles show gradients both in temperature and density. The electrostatic fluctuation measured using a Langmuir probe radially along the non-cusp region shows less than 1% (δIisat/Iisat physics parameter space relevant to both laboratory multi-scale plasmas and astrophysical plasmas.

  20. Quark-Gluon Plasma

    CERN Document Server

    1990-01-01

    This volume contains 14 review articles on the theory and phenomenology of the creation and diagnosis of quark-gluon plasma. They are written by active investigators of in the various research topics, which range from the QCD foundation through transport theory and thermalization models to the examination of possible signatures. The monograph should be useful not only to the experienced researchers in the subject but also to newcomers.

  1. Plasma flame for mass purification of contaminated air with chemical and biological warfare agents

    International Nuclear Information System (INIS)

    Uhm, Han S.; Shin, Dong H.; Hong, Yong C.

    2006-01-01

    An elimination of airborne simulated chemical and biological warfare agents was carried out by making use of a plasma flame made of atmospheric plasma and a fuel-burning flame, which can purify the interior air of a large volume in isolated spaces such as buildings, public transportation systems, and military vehicles. The plasma flame generator consists of a microwave plasma torch connected in series to a fuel injector and a reaction chamber. For example, a reaction chamber, with the dimensions of a 22 cm diameter and 30 cm length, purifies an airflow rate of 5000 lpm contaminated with toluene (the simulated chemical agent) and soot from a diesel engine (the simulated aerosol for biological agents). Large volumes of purification by the plasma flame will free mankind from the threat of airborne warfare agents. The plasma flame may also effectively purify air that is contaminated with volatile organic compounds, in addition to eliminating soot from diesel engines as an environmental application

  2. Cerebral hematocrit decreases with hemodynamic compromise in carotid artery occlusion: a PET study.

    Science.gov (United States)

    Yamauchi, H; Fukuyama, H; Nagahama, Y; Katsumi, Y; Okazawa, H

    1998-01-01

    This study investigated whether in patients with internal carotid artery occlusion the regional cerebral hematocrit correlates with cerebral hemodynamics or metabolic state and, if so, how the regional cerebral hematocrit changes in the hemodynamically compromised region. We used positron emission tomography to study seven patients with unilateral internal carotid artery occlusion and no cortical infarction in the chronic stage. The distributions of red blood cell and plasma volumes were assessed using oxygen-15-labeled carbon monoxide and copper-62-labeled human serum albumin-dithiosemicarbazone tracers, respectively. The calculated hematocrit value was compared with the hemodynamic and metabolic parameters measured with the oxygen-15 steady-state technique. In the cerebral cortex, the value of the cerebral hematocrit varied but was correlated with the hemodynamic and metabolic status. Stepwise regression analysis revealed that the large vessel hematocrit, the cerebral metabolic rate of oxygen, and the cerebral blood flow or the oxygen extraction fraction accounted for a significant proportion of variance of the cerebral hematocrit. The oxygen extraction fraction and the cerebral metabolic rate of oxygen negatively correlated with the cerebral hematocrit, whereas the cerebral blood flow correlated positively: patients with reduced blood supply relative to metabolic demand (decreased blood flow with increased oxygen extraction fraction) showed low hematocrit values. In carotid artery occlusion in the chronic stage, regional cerebral hematocrit may vary according to cerebral hemodynamics and metabolic status. Regional cerebral hematocrit may decrease with hemodynamic compromise unless oxygen metabolism concomitantly decreases.

  3. Effect of pulmonary hyperinflation on central blood volume

    DEFF Research Database (Denmark)

    Mijacika, Tanja; Kyhl, Kasper; Frestad, Daria

    2017-01-01

    (11±7%) above the total lung capacity. All cardiac chambers decreased in volume and despite a heart rate increase of 24±29 bpm (39±50%), pulmonary blood flow decreased by 2783±1820mL (43±20%). The pulmonary transit time remained unchanged at 7.5±2.2s and pulmonary blood volume decreased by 354±176m...

  4. Chiral crossover transition in a finite volume

    Science.gov (United States)

    Shi, Chao; Jia, Wenbao; Sun, An; Zhang, Liping; Zong, Hongshi

    2018-02-01

    Finite volume effects on the chiral crossover transition of strong interactions at finite temperature are studied by solving the quark gap equation within a cubic volume of finite size L. With the anti-periodic boundary condition, our calculation shows the chiral quark condensate, which characterizes the strength of dynamical chiral symmetry breaking, decreases as L decreases below 2.5 fm. We further study the finite volume effects on the pseudo-transition temperature {T}{{c}} of the crossover, showing a significant decrease in {T}{{c}} as L decreases below 3 fm. Supported by National Natural Science Foundation of China (11475085, 11535005, 11690030, 51405027), the Fundamental Research Funds for the Central Universities (020414380074), China Postdoctoral Science Foundation (2016M591808) and Open Research Foundation of State Key Lab. of Digital Manufacturing Equipment & Technology in Huazhong University of Science & Technology (DMETKF2015015)

  5. [Extracellular fluid, plasma and interstitial volume in cirrhotic patients without clinical edema or ascites].

    Science.gov (United States)

    Noguera Viñas, E C; Hames, W; Mothe, G; Barrionuevo, M P

    1989-01-01

    Extracellular fluid volume (E.C.F.) and plasma volume (P.V.), were measured with sodium sulfate labeled with 35I and 131I human serum albumin, respectively, by the dilution technique in control subjects and in cirrhotic patients without clinical ascites or edema, renal or hepatic failure, gastrointestinal bleeding or diuretics. Results are expressed as mean +/- DS in both ml/m2 and ml/kg. In normal subjects E.C.F. (n = 8) was 7,533 +/- 817 ml/m2 (201.3 +/- 182 ml/kg), P.V. (n = 11) 1,767 +/- 337 ml/m2 (47.2 +/- 9.3 ml/kg), and interstitial fluid (I.S.F.) (n = 7) 5,758 +/- 851 ml/m2 (Table 2). In cirrhotic patients E.C.F. (n = 11) was 10,318 +/- 2,980 ml/m2 (261.7 +/- 76.8 ml/kg), P.V. (n = 12) 2,649 +/- 558 ml/m2 (67.7 +/- 15.6 ml/kg) and I.S.F. (n = 11) 7,866 +/- 2,987 ml/m2 (Table 3). Cirrhotic patients compared with normal subjects have hypervolemia due to a significant E.C.F. and P.V. expansion (p less than 0.02 and less than 0.001 respectively) (Fig. 1). Reasons for E.C.F. and P.V. abnormalities in cirrhotic patients may reflect urinary sodium retention related to portal hipertension which stimulates aldosterone release or enhanced renal tubular sensitivity to the hormone. However, it is also possible that these patients, in the presence of hypoalbuminemia (Table 1), have no clinical edema or ascites due to increased glomerular filtration, suppressed release of vasopressin, increased natriuretic factor, and urinary prostaglandin excretion, in response to the intravascular expansion, all of which increased solute and water delivery to the distal nephron and improved renal water excretion. We conclude that in our clinical experience cirrhotic patients without ascites or edema have hypervolemia because of a disturbance in E.C.F.

  6. Spatial diagnostics of the laser induced lithium fluoride plasma

    Energy Technology Data Exchange (ETDEWEB)

    Baig, M. A.; Qamar, Aisha; Fareed, M. A.; Anwar-ul-Haq, M.; Ali, Raheel [Atomic and Molecular Physics Laboratory, Department of Physics, Quaid-i-Azam University, 45320 Islamabad (Pakistan)

    2012-06-15

    We present spatial characteristics of the lithium fluoride plasma generated by the fundamental and second harmonic of a Nd:YAG laser. The plume emission has been recorded spatially using five spectrometers covering the spectral region from 200 nm to 720 nm. The electron density is measured from the Stark broadened line profile of the line at 610.37 nm, whereas the plasma temperature has been determined using the Boltzmann plot method including all the observed spectral lines of lithium. Both the plasma parameters; electron density and plasma temperature decrease with the increase of the distance from the target surface. The thermal conduction towards the target, the radiative cooling of the plasma, and the conversion of thermal energy into kinetic energy are the main mechanisms responsible for the spatially decrease of the plasma parameters.

  7. An overview of plasma-in-liquid experimental studies at the University of Michigan's Plasma Science and Technology Laboratory

    Science.gov (United States)

    Foster, John; Howard, Cameron; Sommers, Bradley

    2010-11-01

    Plasma production or plasma injection in liquid water affords one the opportunity to nonthermally inject advanced oxidation processes into water for the purpose of sterilization or chemical processing. Limitations of current injection approaches include limited throughput capacity, electrode erosion, and reduced process volume. Currently we are investigating two potential approaches to circumventing these issues. These include direct plasma injection using an underwater DBD plasma jet and the direct excitation of underwater isolated bubbles via a pulsed electric field. Presented here are results from these ongoing tests, which include a comparative study of the effectiveness of microdischarge, and plasma jet direct injection approaches on the decomposition of Methylene Blue dye. Additionally, an approach to excitation of isolated bubbles using pulsed electric fields is also discussed. Streamer propagation dynamics such as surface propagation and the observed excitation of surface waves on electrode-attached and free bubbles are also discussed.

  8. Interaction of EM Waves with Atmospheric Pressure Plasmas

    National Research Council Canada - National Science Library

    Laroussi, Mounir

    2000-01-01

    .... The focus of the main activities is the generation of large volume, non-thermal, atmospheric pressure plasmas, their diagnostics, and their interactions with EM waves and with the cells of microorganism...

  9. Insulin does not stimulate muscle protein synthesis during increased plasma branched-chain amino acids alone but still decreases whole body proteolysis in humans.

    Science.gov (United States)

    Everman, Sarah; Meyer, Christian; Tran, Lee; Hoffman, Nyssa; Carroll, Chad C; Dedmon, William L; Katsanos, Christos S

    2016-10-01

    Insulin stimulates muscle protein synthesis when the levels of total amino acids, or at least the essential amino acids, are at or above their postabsorptive concentrations. Among the essential amino acids, branched-chain amino acids (BCAA) have the primary role in stimulating muscle protein synthesis and are commonly sought alone to stimulate muscle protein synthesis in humans. Fourteen healthy young subjects were studied before and after insulin infusion to examine whether insulin stimulates muscle protein synthesis in relation to the availability of BCAA alone. One half of the subjects were studied in the presence of postabsorptive BCAA concentrations (control) and the other half in the presence of increased plasma BCAA (BCAA). Compared with that prior to the initiation of the insulin infusion, fractional synthesis rate of muscle protein (%/h) did not change (P > 0.05) during insulin in either the control (0.04 ± 0.01 vs 0.05 ± 0.01) or the BCAA (0.05 ± 0.02 vs. 0.05 ± 0.01) experiments. Insulin decreased (P BCAA (0.89 ± 0.07 vs 0.61 ± 0.03) experiments, but the change was not different between the two experiments (P > 0.05). In conclusion, insulin does not stimulate muscle protein synthesis in the presence of increased circulating levels of plasma BCAA alone. Insulin's suppressive effect on proteolysis is observed independently of the levels of circulating plasma BCAA. Copyright © 2016 the American Physiological Society.

  10. Perfect storm: Therapeutic plasma exchange for a patient with thyroid storm.

    Science.gov (United States)

    McGonigle, Andrea M; Tobian, Aaron A R; Zink, Jennifer L; King, Karen E

    2018-02-01

    Thyroid storm is a potentially lethal complication of hyperthyroidism with increased thyroid hormones and exaggerated symptoms of thyrotoxicosis. First-line therapy includes methimazole (MMI) or propylthiouracil (PTU) to block production of thyroid hormones as a bridge toward definitive surgical treatment. Untreated thyroid storm has a mortality rate of up to 30%; this is particularly alarming when patients cannot tolerate or fail pharmacotherapy, especially if they cannot undergo thyroidectomy. Therapeutic plasma exchange (TPE) is an ASFA category III indication for thyroid storm, meaning the optimum role of this therapy is not established, and there are a limited number of cases in the literature. Yet TPE can remove T3 and T4 bound to albumin, autoantibodies, catecholamines and cytokines and is likely beneficial for these patients. We report a patient with thyroid storm who could not tolerate PTU, subsequently failed therapy with MMI, and was not appropriate for thyroidectomy. TPE was therefore performed daily for 4 days (1.0 plasma volume with 5% albumin replacement and 2 U of plasma). Over the treatment course, the patient's thyroid hormones normalized and symptoms of thyroid storm largely resolved; his T3 decreased from 2.27 to 0.81 ng/mL (normal 0.8-2.0), T4 decreased from 4.8 to 1.7 ng/mL (0.8-1.8), heart rate normalized, altered mental status improved, and he converted to normal sinus rhythm. He was ultimately discharged in euthyroid state. He experienced no side effects from his TPE procedures. TPE is a safe and effective treatment for thyroid storm when conventional treatments are not successful or appropriate. © 2017 Wiley Periodicals, Inc.

  11. Large area atmospheric-pressure plasma jet

    Science.gov (United States)

    Selwyn, Gary S.; Henins, Ivars; Babayan, Steve E.; Hicks, Robert F.

    2001-01-01

    Large area atmospheric-pressure plasma jet. A plasma discharge that can be operated at atmospheric pressure and near room temperature using 13.56 MHz rf power is described. Unlike plasma torches, the discharge produces a gas-phase effluent no hotter than 250.degree. C. at an applied power of about 300 W, and shows distinct non-thermal characteristics. In the simplest design, two planar, parallel electrodes are employed to generate a plasma in the volume therebetween. A "jet" of long-lived metastable and reactive species that are capable of rapidly cleaning or etching metals and other materials is generated which extends up to 8 in. beyond the open end of the electrodes. Films and coatings may also be removed by these species. Arcing is prevented in the apparatus by using gas mixtures containing He, which limits ionization, by using high flow velocities, and by properly spacing the rf-powered electrode. Because of the atmospheric pressure operation, there is a negligible density of ions surviving for a sufficiently long distance beyond the active plasma discharge to bombard a workpiece, unlike the situation for low-pressure plasma sources and conventional plasma processing methods.

  12. Quark-gluon plasma 2

    CERN Document Server

    1995-01-01

    This is a sequel to the review volume Quark-Gluon Plasma. There are 13 articles contributed by leading investigators in the field, covering a wide range of topics about the theoretical approach to the subject. These contributions are timely reviews of nearly all the actively pursued problems, written in a pedagogical style suitable for beginners as well as experienced researchers.

  13. Investigation of high-current low pressure quasistationary volume discharge in cross-field ExH

    International Nuclear Information System (INIS)

    Bashutin, O.A.; Vovchenko, E.D.; Kirnev, G.S.

    1995-01-01

    Different types of high current discharge permitted to create large volume of high density homogeneous plasma are widely used in modern technique. Such discharges are applied as plasma emitters of charged particles and also in various technologies for sputtering, implantation and etching of materials. The results of a plasma electron density dynamics investigation of low pressure quasistationary volume discharge in cross-field E x H is described in this paper. The discharge was created in a quadrupole magnetic system with special form electrodes and has following characteristics current up to 1,8 kA, voltage on the interval 80-120 V, existence time up to 1,5 ms. The discharge conserves diffusive character of plasma and cathode layer on all current range. On a first research stage plasma parameters of discharge were determined by means of Langmuir probe, that could been used in central discharge region only, where magnetic field was equal to zero. An obtained plasma density was reached 1,5*10 15 cm -3 with electron temperature T e =10 eV. The research of discharge plasma in regions with magnetic field had required to use interferometric measurement technique

  14. Activation volume of martensitic ODS steel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. W.; Noh, S.; Kim, T. K. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Apparent activation volume as a function of temperature is 86b{sup 3}-42b{sup 3}. Activation volume decreases with increasing temperature. Activation volume changes scarcely with decreasing strain rate. Strain rate sensitivity increases with increasing temperature and decreasing strain rate. Nano-sized oxide dispersion strengthened (ODS) martensitic steel has a high strength, low thermal expansion coefficient, high thermal conductivity, and a good swelling resistance. Martensitic ODS steel is a candidate material for fuel cladding of sodium cooled fast breeder reactor (SFR). The plastic flow stress is determined through the interaction of dislocations with the obstacles encountered inside lattice. Dislocation movement through the lattice or past an obstacle requires surmounting of the energy barrier by a combination of applied stress and thermal activation. The plastic deformation of materials is a thermally activated process dependent upon time, temperature, and strain rate. Characterization of the rate controlling mechanism for plastic deformation due to dislocation motion in crystalline materials is done by the assessment of activation volume based on thermal activation analysis.

  15. Plasma atomic layer etching using conventional plasma equipment

    International Nuclear Information System (INIS)

    Agarwal, Ankur; Kushner, Mark J.

    2009-01-01

    The decrease in feature sizes in microelectronics fabrication will soon require plasma etching processes having atomic layer resolution. The basis of plasma atomic layer etching (PALE) is forming a layer of passivation that allows the underlying substrate material to be etched with lower activation energy than in the absence of the passivation. The subsequent removal of the passivation with carefully tailored activation energy then removes a single layer of the underlying material. If these goals are met, the process is self-limiting. A challenge of PALE is the high cost of specialized equipment and slow processing speed. In this work, results from a computational investigation of PALE will be discussed with the goal of demonstrating the potential of using conventional plasma etching equipment having acceptable processing speeds. Results will be discussed using inductively coupled and magnetically enhanced capacitively coupled plasmas in which nonsinusoidal waveforms are used to regulate ion energies to optimize the passivation and etch steps. This strategy may also enable the use of a single gas mixture, as opposed to changing gas mixtures between steps

  16. Thermal energy and bootstrap current in fusion reactor plasmas

    International Nuclear Information System (INIS)

    Becker, G.

    1993-01-01

    For DT fusion reactors with prescribed alpha particle heating power P α , plasma volume V and burn temperature i > ∼ 10 keV specific relations for the thermal energy content, bootstrap current, central plasma pressure and other quantities are derived. It is shown that imposing P α and V makes these relations independent of the magnitudes of the density and temperature, i.e. they only depend on P α , V and shape factors or profile parameters. For model density and temperature profiles analytic expressions for these shape factors and for the factor C bs in the bootstrap current formula I bs ∼ C bs (a/R) 1/2 β p I p are given. In the design of next-step devices and fusion reactors, the fusion power is a fixed quantity. Prescription of the alpha particle heating power and plasma volume results in specific relations which can be helpful for interpreting computer simulations and for the design of fusion reactors. (author) 5 refs

  17. Technical feasibility study on volumetric reduction of radioactive wastes using plasma technology

    Energy Technology Data Exchange (ETDEWEB)

    Prado, E.S.P.; Dellamano, J.C.; Carneiro, A.L.G.; Santos, R.C.; Potiens Junior, A.J. [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Petraconi, G., E-mail: edu.petraconi@usp.br [Instituto Tecnológico da Aeronáutica (ITA), São José dos Campos, SP (Brazil)

    2017-07-01

    The radioactive waste arising from nuclear reactors, hospitals, industry and research institutes are generated daily with a considerable amount. To final dispose of these radioactive waste safely and cost effectively, they must be transformed into physical and chemical compounds suitable for radionuclides immobilization with maximum volume and exhaust gaseous reduction. In this scope, among the promising technologies for the radioactive waste treatment, plasma technology allows reducing substantially the waste volume after exposing them to temperatures above 2,500 deg C. In the planning and management of radioactive waste, the challenges related to plasma technology are presented as a motivation factor for the possible implantation of plasma reactors in nuclear plants and research centers aiming at improving the process of radioactive waste management. (author)

  18. Technical feasibility study on volumetric reduction of radioactive wastes using plasma technology

    International Nuclear Information System (INIS)

    Prado, E.S.P.; Dellamano, J.C.; Carneiro, A.L.G.; Santos, R.C.; Potiens Junior, A.J.; Petraconi, G.

    2017-01-01

    The radioactive waste arising from nuclear reactors, hospitals, industry and research institutes are generated daily with a considerable amount. To final dispose of these radioactive waste safely and cost effectively, they must be transformed into physical and chemical compounds suitable for radionuclides immobilization with maximum volume and exhaust gaseous reduction. In this scope, among the promising technologies for the radioactive waste treatment, plasma technology allows reducing substantially the waste volume after exposing them to temperatures above 2,500 deg C. In the planning and management of radioactive waste, the challenges related to plasma technology are presented as a motivation factor for the possible implantation of plasma reactors in nuclear plants and research centers aiming at improving the process of radioactive waste management. (author)

  19. Plasma generation induced by triboelectrification

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Singh, Shailendra Vikram; Michelsen, Poul

    2009-01-01

    A gas discharge plasma can be induced by triboelectrification around a sliding contact. The detailed physical mechanism of triboelectrification is unknown, but an empirical classification scheme can be referred to in practice. It is reported that intense ultra-violet emission from a plasma...... is observed adjacent to the sliding contact, of which the location has a gap ranging from approximately 1 μm to 11 μm. When the gap is short enough, a theory predicts that the breakdown voltage can monotonically decrease with a decrease in the gap. However, when the gap is comparable to electron’s mean free...

  20. A microwave-augmented plasma torch module

    International Nuclear Information System (INIS)

    Kuo, S P; Bivolaru, Daniel; Williams, Skip; Carter, Campbell D

    2006-01-01

    A new plasma torch device which combines arc and microwave discharges to enhance the size and enthalpy of the plasma torch is described. A cylindrical-shaped plasma torch module is integrated into a tapered rectangular cavity to form a microwave adaptor at one end, which couples the microwave power injected into the cavity from the other end to the arc plasma generated by the torch module. A theoretical study of the microwave coupling from the cavity to the plasma torch, as the load, is presented. The numerical results indicate that the microwave power coupling efficiency exceeds 80%. Operational tests of the device indicate that the microwave power is coupled to the plasma torch and that the arc discharge power is increased. The addition of microwave energy enhances the height, volume and enthalpy of the plasma torch when the torch operates at a low airflow rate, and even when the flow speed is supersonic, a noticeable microwave effect on the plasma torch is observed. In addition, the present design allows the torch to be operated as both a fuel injector and igniter. Ignition of ethylene fuel injected through the centre of a tungsten carbide tube acting as the central electrode is demonstrated

  1. EXPERIMENTAL STUDY OF SHOCK WAVE DYNAMICS IN MAGNETIZED PLASMAS

    International Nuclear Information System (INIS)

    Podder, Nirmol K.

    2009-01-01

    In this four-year project (including one-year extension), the project director and his research team built a shock-wave-plasma apparatus to study shock wave dynamics in glow discharge plasmas in nitrogen and argon at medium pressure (1-20 Torr), carried out various plasma and shock diagnostics and measurements that lead to increased understanding of the shock wave acceleration phenomena in plasmas. The measurements clearly show that in the steady-state dc glow discharge plasma, at fixed gas pressure the shock wave velocity increases, its amplitude decreases, and the shock wave disperses non-linearly as a function of the plasma current. In the pulsed discharge plasma, at fixed gas pressure the shock wave dispersion width and velocity increase as a function of the delay between the switch-on of the plasma and shock-launch. In the afterglow plasma, at fixed gas pressure the shock wave dispersion width and velocity decrease as a function of the delay between the plasma switch-off and shock-launch. These changes are found to be opposite and reversing towards the room temperature value which is the initial condition for plasma ignition case. The observed shock wave properties in both igniting and afterglow plasmas correlate well with the inferred temperature changes in the two plasmas

  2. Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

    International Nuclear Information System (INIS)

    Young, Amy V.; Wortham, Angela; Wernick, Iddo; Evans, Andrew; Ennis, Ronald D.

    2011-01-01

    Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical target volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean ± standard deviation of 32 ± 9 vs. 23 ± 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 ± 3 vs. 21 ± 5 min (p = .003), 39 ± 12 vs. 30 ± 5 min (p = .055), and 29 ± 5 vs. 20 ± 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.

  3. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    International Nuclear Information System (INIS)

    Wagner, Marlies; Kyriakou, Yiannis; Mesnil de Rochemont, Richard du; Singer, Oliver C.; Berkefeld, Joachim

    2013-01-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy

  4. Role of cardiac volume receptors in the control of ADH release during acute simulated weightlessness in man

    Science.gov (United States)

    Convertino, V. A.; Benjamin, B. A.; Keil, L. C.; Sandler, H.

    1984-01-01

    Hemodynamic responses and antidiuretic hormone (ADH) were measured during body position changes, designed to induce central blood volume shifts in ten cardiac and one heart-lung transplant recipients, to assess the contribution of cardiac volume receptors in the control of ADH release during the initial acute phase of exposure to weightlessness. Each subject underwent 15 min of a sitting-control period (C) followed by 30 min of 6 deg headdown tilt (T) and 30 min of resumed sitting (S). Venous blood samples and cardiac dimensions were taken at 0 and 15 min of C; 5, 15, and 30 min of T; and 5, 15, and 30 min of S. Blood samples were analyzed for hematocrit, plasma osmolality, plasma renin activity (PRA), and ADH. Heart rate and blood pressure were recorded every two min. Plasma osmolality was not altered by posture changes. Mean left ventricular end-diastolic volume increased (P less than 0.05) from 90 ml in C to 106 ml in T and returned to 87 ml in S. Plasma ADH was reduced by 20 percent (P less than 0.05) with T, and returned to control levels with S. These responses were similar in six normal cardiac-innervated control subjects. These data may suggest that cardiac volume receptors are not the primary mechanism for the control of ADH release during acute central volume shifts in man.

  5. Decreased insulin response in dairy cows following a four-day fast to induce hepatic lipidosis.

    Science.gov (United States)

    Oikawa, S; Oetzel, G R

    2006-08-01

    Negative energy balance has been implicated in the development of fatty liver, insulin resistance, and impaired health in dairy cows. A 4-d fasting model previously was reported to increase liver triglycerides more than 2.5-fold. The purpose of the present study was to evaluate insulin response in this fasting model. Nonlactating, nonpregnant Holstein cows were fasted for 4 d (6 cows) or fed continuously as control cows (4 cows). Samples were collected 5 d before fasting, during fasting, and immediately after the 4-d fast, 8 d after the fast, and 16 d after the fast. Fasted cows had greater liver triglyceride content (49.4 vs. 16.2 mg/g, wet-weight basis) at the end of the fasting period compared with control cows. Fasted cows also had increased plasma nonesterified fatty acid (NEFA) concentrations (1.24 vs. 0.21 mmol/L) and increased plasma beta-hydroxybutyrate (BHBA) concentrations at the end of the fasting period. Liver triglyceride, plasma NEFA, and plasma BHBA in fasted cows returned to prefasting concentrations by the end of the experiment. Plasma glucose concentrations were not affected by fasting. Plasma insulin concentrations were decreased (6.3 vs. 14.1 microU/mL) and insulin-stimulated blood glucose reduction was decreased (24.9 vs. 48.6%) in the fasted cows compared with control cows at the end of the fast, indicating reduced insulin response. Insulin response was negatively correlated with plasma NEFA and liver triglycerides. Decreased insulin response may be an important complication of negative energy balance and hepatic lipidosis.

  6. plasmaFoam: An OpenFOAM framework for computational plasma physics and chemistry

    Science.gov (United States)

    Venkattraman, Ayyaswamy; Verma, Abhishek Kumar

    2016-09-01

    As emphasized in the 2012 Roadmap for low temperature plasmas (LTP), scientific computing has emerged as an essential tool for the investigation and prediction of the fundamental physical and chemical processes associated with these systems. While several in-house and commercial codes exist, with each having its own advantages and disadvantages, a common framework that can be developed by researchers from all over the world will likely accelerate the impact of computational studies on advances in low-temperature plasma physics and chemistry. In this regard, we present a finite volume computational toolbox to perform high-fidelity simulations of LTP systems. This framework, primarily based on the OpenFOAM solver suite, allows us to enhance our understanding of multiscale plasma phenomenon by performing massively parallel, three-dimensional simulations on unstructured meshes using well-established high performance computing tools that are widely used in the computational fluid dynamics community. In this talk, we will present preliminary results obtained using the OpenFOAM-based solver suite with benchmark three-dimensional simulations of microplasma devices including both dielectric and plasma regions. We will also discuss the future outlook for the solver suite.

  7. Turbulence, selective decay, and merging in the SSX plasma wind tunnel

    Science.gov (United States)

    Gray, Tim; Brown, Michael; Flanagan, Ken; Werth, Alexandra; Lukin, V.

    2012-10-01

    A helical, relaxed plasma state has been observed in a long cylindrical volume. The cylinder has dimensions L = 1 m and R = 0.08 m. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v >=50 km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. Typical plasma parameters are Ti= 25 eV, ne>=10^15 cm-3, and B = 0.25 T. The relaxed state is rapidly attained in 1--2 axial Alfv'en times after initiation of the plasma. Magnetic data is favorably compared with an analytical model. Magnetic data exhibits broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement to the minimum energy eigenstate of ∇xB = λB. While the global structure roughly corresponds to the minimum energy eigenstate for the wind tunnel geometry, the plasma is high beta (β= 0.5) and does not have a flat λ profile. Merging of two plasmoids in this configuration results in noticeably more dynamic activity compared to a single plasmoid. These episodes of activity exhibit s

  8. Early changes in volume and non-enhanced volume of acoustic neurinoma after stereotactic gamma-radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Mori, Yoshimasa; Iwakoshi, Takayasu; Niwa, Masahiro; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1994-09-01

    The effectiveness of stereotactic gamma-radiosurgery for treating acoustic neurinoma was evaluated by measuring the volumes of the tumor, non-enhanced tumor, and cerebellar edema in 13 patients with acoustic neurinoma who were followed up for 9 to 15 months (median 12.7 mos) after treatment. The tumor volume and non-enhanced volume tended to reach a maximum after 6 months, and cerebellar edema volume after 9 months, then decreased gradually thereafter. Hearing loss tended to increase gradually, but involvement of the facial nerve was transient. (author).

  9. Mineral profiling of ostrich (Struthio camelus) seminal plasma and its relationship with semen traits and collection day.

    Science.gov (United States)

    Smith, A M J; Bonato, M; Dzama, K; Malecki, I A; Cloete, S W P

    2018-06-01

    Successful assisted reproduction techniques, with specific focus on in vitro semen storage for artificial insemination, are dependent on certain key elements which includes the biochemical profiling of semen. The objective of this study was to complete an ostrich seminal plasma (SP) evaluation by inductively coupled plasma mass spectrometry (ICP-MS) among seven males at different daily intervals (day 1, 3, 7, 11, 15, 19, 21, 23, 25, 26, 27, 28) for a period of 28 days during spring (August to September) for mineral profiling. The effect of collection day and male on sperm concentration, semen volume and seminal plasma volume, was explored as well as the relationships amongst these specific sperm traits and SP minerals. Variation amongst SP mineral concentrations, accounted for by the fixed effects of sperm concentration, semen volume, seminal plasma volume, collection day and male, ranged from 18% to 77%. Male had the largest effect on variation in SP minerals, namely: phosphorus (P), potassium (K), calcium (Ca), sodium (Na), boron (B), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), molybdenum (Mo), barium (Ba), arsenic (As) and selenium (Se). Sperm concentration instigated fluctuations of P, magnesium (Mg), B, zinc (Zn), Fe, aluminium (Al), Se, manganese (Mn) and lead (Pb). Semen volume had an effect on Na, K, B, Pb and Ba while seminal plasma volume only influenced variation in Na. There were fluctuations among collection days of specific micro minerals, Ni and Mo, with initial Ni concentrations being relatively greater and Mo at lesser concentrations. Semen volume, seminal plasma volume and sperm concentration varied amongst males. Sperm concentrations during the initial collection days, 1 and 3, were less than that for days 7 to 28. Significant variation of SP minerals and sperm characteristics among ejaculates and males suggest an association of these specific elements with sperm function and are, therefore, considered to be of potential importance to

  10. Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity

    International Nuclear Information System (INIS)

    Ahmed, Shahid; Mammosser, John D.

    2015-01-01

    A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar–O 2 (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM 010 -mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper

  11. Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Shahid, E-mail: shahid.ahmed@ieee.org [BML Munjal University, Gurgaon, Haryana 123413 (India); Mammosser, John D. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2015-07-15

    A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar–O{sub 2} (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM{sub 010}-mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper.

  12. Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity

    Science.gov (United States)

    Ahmed, Shahid; Mammosser, John D.

    2015-07-01

    A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar-O2 (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM010-mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper.

  13. Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity.

    Science.gov (United States)

    Ahmed, Shahid; Mammosser, John D

    2015-07-01

    A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar-O2 (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM010-mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper.

  14. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  15. Increasing platelet concentrations in leukocyte-reduced platelet-rich plasma decrease collagen gene synthesis in tendons.

    Science.gov (United States)

    Boswell, Stacie G; Schnabel, Lauren V; Mohammed, Hussni O; Sundman, Emily A; Minas, Tom; Fortier, Lisa A

    2014-01-01

    Platelet-rich plasma (PRP) is used for the treatment of tendinopathy. There are numerous PRP preparations, and the optimal combination of platelets and leukocytes is not known. Within leukocyte-reduced PRP (lrPRP), there is a plateau effect of platelet concentration, with increasing platelet concentrations being detrimental to extracellular matrix synthesis. Controlled laboratory study. Different formulations of lrPRP with respect to the platelet:leukocyte ratio were generated from venous blood of 8 horses. Explants of the superficial digital flexor tendon were cultured in lrPRP products for 96 hours. Platelet-derived growth factor-BB (PDGF-BB), tumor necrosis factor-α (TNF-α), transforming growth factor-β1 (TGF-β1), and interleukin-1β (IL-1β) concentrations were determined in the media by enzyme-linked immunosorbent assay. Gene expression in tendon tissue for collagen type I and III (COL1A1 and COL3A1, respectively), matrix metalloproteinase-3 and -13 (MMP-3 and MMP-13, respectively), cartilage oligomeric matrix protein (COMP), and IL-1β was determined. Data were divided into 3 groups of lrPRP based on the ratio of platelets:leukocytes and evaluated to determine the effect of platelet concentration. Complete blood counts verified leukocyte reduction and platelet enrichment in all PRP preparations. In the lrPRP preparation, the anabolic growth factors PDGF-BB and TGF-β1 were increased with increasing platelet concentrations, and the catabolic cytokine IL-1β was decreased with increasing platelet concentrations. Increasing the platelet concentration resulted in a significant reduction in COL1A1 and COL3A1 synthesis in tendons. Increasing the platelet concentration within lrPRP preparations results in the delivery of more anabolic growth factors and less proinflammatory cytokines, but the biological effect on tendons is diminished metabolism as indicated by a decrease in the synthesis of both COL1A1 and COL3A1. Together, this information suggests that

  16. Plasma intermedin concentration in patients with chronic heart faliure

    International Nuclear Information System (INIS)

    Yu Xiaohua; Du Xingbang; Zhu Yunhe; Luo Lei; Zhao Changjun; Liu Yongfeng; Ren Liangping; Ren Yongsheng

    2011-01-01

    Objective: To study the clinical significance of determination of changes of plasma levels of intermedin (IMD), BNP and CRP in patients with chronic heart failure. Methods: Plasma IMD, BNP (with RIA) and CRP (with immuno-turbidity) levels were determined in 46 patients with chronic heart failure of various grades (grade I-II n=31, grade III-IV, n=15) and 42 normal controls. Results: Compared with the control group,the plasma IMD level in patients with chronic heart failure was decreased 53.2% (P<0.01), the BNP and CRP were increased 1658.5% and 80.5% respectively (each P<0.001). Compared with the grade I-II group, the plasma IMD level in grade III-IV was decreased 34.7% (P<0.05), the BNP and CRP levels in grade III-IV were increased 257.8% and 76% (all P<0.001) individually. Conclusion: Plasma intermedin concentration was significantly decreased in patients with chronic heart failure, which suggests that they play an important role in the pathogenesis of chronic heart failure. (authors)

  17. An investigation of transient pressures and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with several plasma diagnostics; they were: a rapid response pressure transducer, a magnetic field probe, a voltage probe, and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior: (1) strong axial pressure asymmetry noted early in plasma column lifetime, (2) followed by plasma heating in which there is a rapid rise in static pressure, and (3) a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating could be attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity.

  18. A partially ionized plasma modeling; Un modele de plasma partiellement ionise

    Energy Technology Data Exchange (ETDEWEB)

    Le Thanh, K.C.; Raviart, P.A

    2003-07-01

    We propose a model for the partially ionized plasma sheaths near the anode of an anodic spot electric arc where the cathode is considered as an electron emitter. A fluid description takes into account the heating and the ionization of the plasma induced by the electron beam. As physical hypothesis we assume that the condition of charge neutrality is valid. According that the electron mass can be neglected compared to the ion mass, we can assume that ions and atoms have the same velocity and the same temperature. Electrons and heavy particles are then regarded as two separate fluids coexisting in the plasma. Governing equations are then multi-fluid equations with relaxation correction to the local thermodynamic equilibrium (LTE) and heating by Joule effect. Equations are solved by an operator splitting procedure. That is we first discretize the homogeneous conservation laws (i.e. without source terms) by a finite volume method. The second step is to solve the ordinary differential system (i.e, governing equation without transport terms) with an implicit scheme. (authors)

  19. DAMAVAND - An Iranian tokamak with a highly elongated plasma cross-section

    International Nuclear Information System (INIS)

    Amrollahi, R.

    1997-01-01

    The ''DAMAVAND'' facility is an Iranian Tokamak with a highly elongated plasma cross-section and with a poloidal divertor. This Tokamak has the advantage to allow the plasma physics research under the conditions similar to those of ITER magnetic configuration. For example, the opportunity to reproduce partially the plasma disruptions without sacrificing the studies of: equilibrium, stability and control over the elongated plasma cross-section; processes in the near-wall plasma; auxiliary heating systems, etc. The range of plasma parameters, the configuration of ''DAMAVAND'' magnetic coils and passive loops, and their location within the vacuum chamber allow the creation of the plasma at the center of the vacuum chamber and the production of two poloidal volumes (upper and lower) for the divertor. (author)

  20. Therapeutic plasma exchange: a paired comparison of Fresenius AS104 vs. COBE Spectra.

    Science.gov (United States)

    Burgstaler, E A; Pineda, A A

    2001-01-01

    For therapeutic plasma exchange (TPE), continuous flow separators are known to be efficient as exemplified by Fresenius AS104 and COBE Spectra. The AS104 uses an interface monitoring system in the centrifuge during TPE, whereas Spectra uses computer algorithms to establish the plasma-cell interface. To determine the plasma collection efficiency (PLCE), anticoagulant (AC) volumes used, and platelets (PLT) lost of the AS104 and the Spectra, we performed a prospective paired comparison of 20 TPE (each machine). The study included 17 patients, 1.3 plasma volume exchanges (without AC), equal inlet rates, and AC ratio of 13:1. Processing times did not include reinfuse mode. Platelet loss was determined by sampling the collection bags. Inlet rates were between 60-110 ml/min. Diagnosis included peripheral neuropathies, TTP and cryoglobulinemia. The AS104 had significantly (P<0.0001) lower average whole blood processed (F:6,601 vs. S:8,584 ml), AC volume (F:532 vs. S:719 ml), and processing time (F:80 vs. S:102 minutes) than Spectra. The AS104 had significantly (P<0.0001) higher average plasma flow rates (F:53 vs. S:44 ml/minute), plasma collection efficiency (F:90 vs. S:69%), and platelet loss (F:2.0 vs. S:0.14 x 10(11) plt) than Spectra. Platelet loss correlated with inlet flow rate with the AS104 but not with the Spectra. The AS104 has a significantly higher collection efficiency than Spectra allowing it to remove the same amount of plasma in significantly less time, by processing significantly less blood, using significantly less AC, but removing significantly more platelets than Spectra. Copyright 2001 Wiley-Liss, Inc.

  1. Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine

    Science.gov (United States)

    Laroussi, M.; Lu, X.; Keidar, M.

    2017-07-01

    Low temperature plasmas have been used in various plasma processing applications for several decades. But it is only in the last thirty years or so that sources generating such plasmas at atmospheric pressure in reliable and stable ways have become more prevalent. First, in the late 1980s, the dielectric barrier discharge was used to generate relatively large volume diffuse plasmas at atmospheric pressure. Then, in the early 2000s, plasma jets that can launch cold plasma plumes in ambient air were developed. Extensive experimental and modeling work was carried out on both methods and much of the physics governing such sources was elucidated. Starting in the mid-1990s, low temperature plasma discharges have been used as sources of chemically reactive species that can be transported to interact with biological media, cells, and tissues and induce impactful biological effects. However, many of the biochemical pathways whereby plasma affects cells remain not well understood. This situation is changing rather quickly because the field, known today as "plasma medicine," has experienced exponential growth in the last few years thanks to a global research community that engaged in fundamental and applied research involving the use of cold plasma for the inactivation of bacteria, dental applications, wound healing, and the destruction of cancer cells/tumors. In this perspective, the authors first review the physics as well as the diagnostics of the principal plasma sources used in plasma medicine. Then, brief descriptions of their biomedical applications are presented. To conclude, the authors' personal assessment of the present status and future outlook of the field is given.

  2. Two dimensional radial gas flows in atmospheric pressure plasma-enhanced chemical vapor deposition

    Science.gov (United States)

    Kim, Gwihyun; Park, Seran; Shin, Hyunsu; Song, Seungho; Oh, Hoon-Jung; Ko, Dae Hong; Choi, Jung-Il; Baik, Seung Jae

    2017-12-01

    Atmospheric pressure (AP) operation of plasma-enhanced chemical vapor deposition (PECVD) is one of promising concepts for high quality and low cost processing. Atmospheric plasma discharge requires narrow gap configuration, which causes an inherent feature of AP PECVD. Two dimensional radial gas flows in AP PECVD induces radial variation of mass-transport and that of substrate temperature. The opposite trend of these variations would be the key consideration in the development of uniform deposition process. Another inherent feature of AP PECVD is confined plasma discharge, from which volume power density concept is derived as a key parameter for the control of deposition rate. We investigated deposition rate as a function of volume power density, gas flux, source gas partial pressure, hydrogen partial pressure, plasma source frequency, and substrate temperature; and derived a design guideline of deposition tool and process development in terms of deposition rate and uniformity.

  3. Plasma physics and controlled nuclear fusion research 1988. V.3

    International Nuclear Information System (INIS)

    1989-01-01

    Volume 3 of the proceedings of the twelfth international conference on plasma physics and controlled nuclear fusion, held in Nice, France, 12-19 October, 1988, contains papers presented on inertial fusion. Direct and indirect laser implosion experiments, programs of laser construction, computer modelling of implosions and resulting plasmas, and light ion beam fusion experiments are discussed. Refs, figs and tabs

  4. A scalable, micropore, platelet rich plasma separation device.

    Science.gov (United States)

    Dickson, Mary Nora; Amar, Levy; Hill, Michael; Schwartz, Joseph; Leonard, Edward F

    2012-12-01

    We have designed a novel, low energy platelet-rich-plasma (PRP) separator capable of producing 50 mL of PRP in 30 min, intended for military and emergency applications. Blood flows over a 3 mm length of sieve at high rates of shear. A plasma-platelet filtrate passes through the sieve's pores while erythrocytes remain. The filtrate is flowed over a second 3 mm length of smaller-pored sieve that withdraws plasma. Bulk blood volume is maintained by returning platelet-free plasma to the erythrocyte pool, enabling a nearly complete multi-pass platelet extraction. The total percentage of platelets extracted is:θ(T)=1-exp (-V(f)(T)Φ(P)/V) where V is the original plasma volume, V ( f )(T) is the total filtered volume, and ϕ ( P ) is platelet passage ratio (filtrate concentration/bulk average concentration) taken to be constant. Maximum θ(T) occurs at maximum V ( f )(T)× ϕ ( P ) Test microsieves, 3 mm long × 3 mm wide, were used. ϕ ( P ) values measured at various filtrate flow rates (20-100 uL/min) and utilizing various filter pore sizes (1.2-3.5 μm), was as high as 150 %. Maximum V ( f )(T)× ϕ ( P ) was achieved utilizing the 3.5 um filters at the highest flow rate, 100 uL/min. Erythrocyte leakages were always below 2,000/uL, far below the allowable limit stipulated by the American Association of Blood Banking. These data imply that a 13.7 cm(2) filter area is sufficient to achieve the target separation of 50 mL of platelet concentrate in 30 min. The filtration cartridge would consist of multiple microporous strips of 3 mm width arranged in parallel so that each element would see the conditions used in the prototype experiments presented here. Other microfiltration schemes suggest no method of scaling to practical levels.

  5. Effects of L-thyroxine on plasma biochemistry in broiler chicks (Gallus gallus)

    International Nuclear Information System (INIS)

    Chaudhry, M.A.; Siddiqui, Z.H.; Imran, M.; Ahsan, M.

    2009-01-01

    The effect of a single intraperitoneal injection of a low dose (1 mu g/g) and a high dose (4 mu /g) of thyroxine (T 4) were investigated with time on plasma metabolites in broiler (Hubbard) chicks. Plasma total proteins, albumin fraction, glucose and triglyceride levels were decreased significantly in both experimental groups. The plasma cholesterol values remained almost comparable with controls during the early stages of the experiment but after 72 hours of the experiment higher dose of T 4 resulted in a significant (p<0.01) decrease followed by significant (p<0.05) increase in the same experimental group. The plasma albumin fraction decreased significantly in animals injected with higher dose of T/sub 4/ after 24 hours and the same trend continue even after 72 hour of the experiment. Plasma uric acid values were significantly decreased in group administered with lower dose of T/sub 4/ after 12 hours of the post injection time. However in animals administered with higher dose of thyroid hormone reflected a significant increase in plasma uric acid levels after 12 hours of the experiment and its levels were significantly decreased after 48 hours. The results are discussed in the light of previous reports of thyroid hormones and their physiological implications in different vertebrate groups. (author)

  6. Estimation of post disruption plasma temperature for fast current quench Aditya plasma shots

    International Nuclear Information System (INIS)

    Purohit, S.; Chowdhuri, M.B.; Joisa, Y.S.; Raval, J.V.; Ghosh, J.; Jha, R.

    2013-01-01

    Characteristics of tokamak current quenches are an important issue for the determination of electromagnetic forces that act on the in-vessel components and vacuum vessel during major disruptions. It is observed that thermal quench is followed by a sharp current decay. Fast current quench disruptive plasma shots were investigated for ADITYA tokamak. The current decay time was determined for the selected shots, which were in the range of 0.8 msec to 2.5 msec. This current decay information was then applied to L/R model, frequently employed for the estimation of the current decay time in tokamak plasmas, considering plasma inductance and plasma resistivity. This methodology was adopted for the estimation of the post disruption plasma temperature using the experimentally observed current decay time for the fast current quench disruptive ADITYA plasma shots. The study reveals that for the identified shots there is a constant increase in the current decay time with the post disruption plasma temperature. The investigations also explore the behavior post disruption plasma temperature and the current decay time as a function of the edge safety factor, Q. Post disruption plasma temperature and the current decay time exhibits a decrease with the increase in the value Q. (author)

  7. Studies on the Hemodynamic Change in Cirrhosis of the Liver

    International Nuclear Information System (INIS)

    Kim, Jung Il; Lee, Jung Sang; Koh, Chang Soon

    1970-01-01

    Cardiac output, plasma volume and renal plasma flow were determined to evaluate hemodynamic changes in 29 patients with cirrhosis of the liver. The results obtained were as follows. 1) The mean plasma volume was 3793±895 ml and it was significantly higher than the normal controls. The mean blood volume (5266±1222 ml) and blood volume per kg body weight (95.7±23.41 ml) were also increased significantly. The mean plasma volume per kg body weight (69.1±19.1 ml) showed increased tendency and the mean difference between blood volume and plasma volume per kg body weight (26.4±7.05 ml) was in lower limit of normal range. 2) The mean cardiac output was 7708±2652 ml/min and it was significantly increased. The mean cardiac index (4924±1998 ml/min/M 2 ), stroke volume (96.2±34.2 ml/beat), stroke index (62.3±27.34 ml/beat/M 2 ) and fractional cardiac index (1.54±0.577) were also increased significantly. The mean total peripheral resistance was 1664±753.8 dynes sec cm -5 M 2 and it was significantly lower than the normal controls. 3) The mean renal plasma flow was 537±146.8 ml/min/1.73M 2 and it was normal to decreased tendency. The mean endogenous creatinine clearance (66.7±23.0 ml/min/1.73M 2 ) was significantly decreased. Filtration fraction was variable, but it was slightly lower than normal in most cases. The mean renal fraction of cardiac output (11.4±6.27%) was relatively decreased. 4) Although renal plasma flow was normal or decreased in general, it was definitely diminished in patients with creatinine clearance less than 60 ml/min/1.73M 2 , resistant ascites, and signs of azotemia (elevated BUN and serum creatinine). 5) Diminished glomerular filtration rate with low filtration fraction and decreased renal fraction of cardiac output observed strongly supported increased renal afferent arteriolar resistance. 6) Renal circulatory impairment preceded azotemia or oroliguria in cirrhosis. 7) Clinical findings and liver function were not correlated with

  8. Localization of waves in a fluctuating plasma

    International Nuclear Information System (INIS)

    Escande, D.F.; Souillard, B.

    1984-01-01

    We present the first application of localization theory to plasma physics: Density fluctuations induce exponential localization of longitudinal and transverse electron plasma waves, i.e., the eigenmodes have an amplitude decreasing exponentially for large distances without any dissipative mechanism in the plasma. This introduces a new mechanism for converting a convective instability into an absolute one. Localization should be observable in clear-cut experiments

  9. Sheet Fluorescence and Annular Analysis of Ultracold Neutral Plasmas

    International Nuclear Information System (INIS)

    Castro, J.; Gao, H.; Killian, T. C.

    2009-01-01

    Annular analysis of fluorescence imaging measurements on Ultracold Neutral Plasmas (UNPs) is demonstrated. Spatially-resolved fluorescence imaging of the strontium ions produces a spectrum that is Doppler-broadened due to the thermal ion velocity and shifted due to the ion expansion velocity. The fluorescence excitation beam is spatially narrowed into a sheet, allowing for localized analysis of ion temperatures within a volume of the plasma with small density variation. Annular analysis of fluorescence images permits an enhanced signal-to-noise ratio compared to previous fluorescence measurements done in strontium UNPs. Using this technique and analysis, plasma ion temperatures are measured and shown to display characteristics of plasmas with strong coupling such as disorder induced heating and kinetic energy oscillations.

  10. The observation on plasma endothelin levels in patients with graves' disease

    International Nuclear Information System (INIS)

    Hao Xiaojun; Liu Changshan; Yang Lianrong; Zhang Qiliang; Wang Honggang; Liu Xudong

    2002-01-01

    Observing the plasma endothelin levels in patients with Graves' disease to probe its clinical significance, plasma endothelin levels were measured in 55 cases of Graves' disease before and after treatment respectively, and these were compared with that of 23 health subjects. Results: plasma endothelin levels in patients with Graves' disease significantly increase, compared with heath subjects (150.4 +- 29.31 ng/L vs 42.80 +- 7.58 ng/L, P < 0.01); post-treatment endothelin levels apparently decrease (97.61 +- 15.99 ng/L vs 150.4 +- 29.31 ng/L, P < 0.01). Plasma endothelin levels in patients with Graves' disease significantly increase, and after treatment the endothelin levels decrease following decreasing of thyroid hormone level and high hemodynamics

  11. Adaptive Radiotherapy Planning on Decreasing Gross Tumor Volumes as Seen on Megavoltage Computed Tomography Images

    International Nuclear Information System (INIS)

    Woodford, Curtis; Yartsev, Slav; Dar, A. Rashid; Bauman, Glenn; Van Dyk, Jake

    2007-01-01

    Purpose: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV. Methods and Materials: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages of replanning for patients with differing GTV regression characteristics. Results: Average GTV change observed over 30 fractions was -38%, ranging from -12 to -87%. No significant correlation was observed between GTV change and patient's physical or tumor features. Patterns of GTV changes in the 17 patients could be divided broadly into three groups with distinctive potential for benefit from adaptive planning. Conclusions: Changes in GTV are difficult to predict quantitatively based on patient or tumor characteristics. If changes occur, there are points in time during the treatment course when it may be appropriate to adapt the plan to improve sparing of normal tissues. If GTV decreases by greater than 30% at any point in the first 20 fractions of treatment, adaptive planning is appropriate to further improve the therapeutic ratio

  12. An investigation of transient pressure and plasma properties in a pinched plasma column. M.S. Thesis

    Science.gov (United States)

    Stover, E. K.; York, T. M.

    1971-01-01

    The transient pinched plasma column generated in a linear Z-pinch was studied experimentally and analytically. The plasma column was investigated experimentally with the following plasma diagnostics: a special rapid response pressure transducer, a magnetic field probe, a voltage probe and discharge luminosity. Axial pressure profiles on the discharge chamber axis were used to identify three characteristic regions of plasma column behavior; they were in temporal sequence: strong axial pressure asymmetry noted early in plasma column lifetime followed by plasma heating in which there is a rapid rise in static pressure and a slight decrease static pressure before plasma column breakup. Plasma column lifetime was approximately 5 microseconds. The axial pressure asymmetry was attributed to nonsimultaneous pinching of the imploding current sheet along the discharge chamber axis. The rapid heating is attributed in part to viscous effects introduced by radial gradients in the axial streaming velocity. Turbulent heating arising from discharge current excitation of the ion acoustic wave instability is also considered a possible heating mechanism.

  13. Atmospheric and Space Sciences: Ionospheres and Plasma Environments

    Science.gov (United States)

    Yiǧit, Erdal

    2018-01-01

    The SpringerBriefs on Atmospheric and Space Sciences in two volumes presents a concise and interdisciplinary introduction to the basic theory, observation & modeling of atmospheric and ionospheric coupling processes on Earth. The goal is to contribute toward bridging the gap between meteorology, aeronomy, and planetary science. In addition recent progress in several related research topics, such atmospheric wave coupling and variability, is discussed. Volume 1 will focus on the atmosphere, while Volume 2 will present the ionospheres and the plasma environments. Volume 2 is aimed primarily at (research) students and young researchers that would like to gain quick insight into the basics of space sciences and current research. In combination with the first volume, it also is a useful tool for professors who would like to develop a course in atmospheric and space physics.

  14. Voluntary wheel running increases bile acid as well as cholesterol excretion and decreases atherosclerosis in hypercholesterolemic mice.

    Science.gov (United States)

    Meissner, Maxi; Lombardo, Elisa; Havinga, Rick; Tietge, Uwe J F; Kuipers, Folkert; Groen, Albert K

    2011-10-01

    Regular physical activity decreases the risk for atherosclerosis but underlying mechanisms are not fully understood. We questioned whether voluntary wheel running provokes specific modulations in cholesterol turnover that translate into a decreased atherosclerotic burden in hypercholesterolemic mice. Male LDLR-deficient mice (8 weeks old) had either access to a voluntary running wheel for 12 weeks (RUN) or remained sedentary (CONTROL). Both groups were fed a western-type/high cholesterol diet. Running activity and food intake were recorded. At 12 weeks of intervention, feces, bile and plasma were collected to determine fecal, biliary and plasma parameters of cholesterol metabolism and plasma cytokines. Atherosclerotic lesion size was determined in the aortic root. RUN weighed less (∼13%) while food consumption was increased by 17% (p=0.004). Plasma cholesterol levels were decreased by 12% (p=0.035) and plasma levels of pro-atherogenic lipoproteins decreased in RUN compared to control. Running modulated cholesterol catabolism by enhancing cholesterol turnover: RUN displayed an increased biliary bile acid secretion (68%, p=0.007) and increased fecal bile acid (93%, p=0.009) and neutral sterol (33%, p=0.002) outputs compared to control indicating that reverse cholesterol transport was increased in RUN. Importantly, aortic lesion size was decreased by ∼33% in RUN (p=0.033). Voluntary wheel running reduces atherosclerotic burden in hypercholesterolemic mice. An increased cholesterol turnover, specifically its conversion into bile acids, may underlie the beneficial effect of voluntary exercise in mice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Placental Underperfusion in a Rat Model of Intrauterine Growth Restriction Induced by a Reduced Plasma Volume Expansion.

    Directory of Open Access Journals (Sweden)

    Karine Bibeau

    Full Text Available Lower maternal plasma volume expansion was found in idiopathic intrauterine growth restriction (IUGR but the link remains to be elucidated. An animal model of IUGR was developed by giving a low-sodium diet to rats over the last week of gestation. This treatment prevents full expansion of maternal circulating volume and the increase in uterine artery diameter, leading to reduced placental weight compared to normal gestation. We aimed to verify whether this is associated with reduced remodeling of uteroplacental circulation and placental hypoxia. Dams were divided into two groups: IUGR group and normal-fed controls. Blood velocity waveforms in the main uterine artery were obtained by Doppler sonography on days 14, 18 and 21 of pregnancy. On day 22 (term = 23 days, rats were sacrificed and placentas and uterine radial arteries were collected. Diameter and myogenic response of uterine arteries supplying placentas were determined while expression of hypoxia-modulated genes (HIF-1α, VEGFA and VEGFR2, apoptotic enzyme (Caspase -3 and -9 and glycogen cells clusters were measured in control and IUGR term-placentas. In the IUGR group, impaired blood velocity in the main uterine artery along with increased resistance index was observed without alteration in umbilical artery blood velocity. Radial uterine artery diameter was reduced while myogenic response was increased. IUGR placentas displayed increased expression of hypoxia markers without change in the caspases and increased glycogen cells in the junctional zone. The present data suggest that reduced placental and fetal growth in our IUGR model may be mediated, in part, through reduced maternal uteroplacental blood flow and increased placental hypoxia.

  16. Numerical simulation of a novel non-transferred arc plasma torch operating with nitrogen

    International Nuclear Information System (INIS)

    Hiremath, Gavisiddayya; Kandasamy, Ramachandran; Ganesh, Ravi

    2015-01-01

    High power plasma torches with higher electro-thermal efficiency are required for industrial applications. To increase the plasma power and electrothermal efficiency, conventional torches are being modified to operate with molecular gases such as air and nitrogen. Since increasing arc current enhances the heat loss to the anode, torches are being developed to operate under high voltage and low current. The plasma flow dynamics and electromagnetic coupling with plasma flow inside the torch etc. are highly complex and knowledge on the same is required to develop high torches with higher efficiency. Unfortunately detailed experimentation on the same is very difficult. Numerical modeling and simulation is one of the best tools to understand the physics involved in such complex processes. A 2D numerical model is developed to simulate the characteristics of the plasma inside the torch. Though plasma is not in local thermodynamic equilibrium (LTE) close to the electrodes, LTE is assumed everywhere in the plasma to avoid complex and time consuming calculations. Other valid assumptions used in the model are plasma flow is optically thin, laminar and incompressible. Flow, energy and electromagnetic equations are solved with appropriate boundary conditions and volume sources using SIMPLE algorithm with finite volume method. Temperature dependent thermophysical properties of nitrogen are used for the simulations. Simulations are carried out for different experimental conditions. The effects of arc current, gas flow rate of plasma generating gas and sheath gas injected above the bottom anode on the arc voltage, electrothermal efficiency of the torch, plasma temperature and plasma velocity are simulated. Predicted results are compared with experimental results. (author)

  17. Plasma Structure and Behavior of Miniature Ring-Cusp Discharges

    Science.gov (United States)

    Mao, Hann-Shin

    Miniature ring-cusp ion thrusters provide a unique blend of high efficiencies and millinewton level thrust for future spacecraft. These thrusters are attractive as a primary propulsion for small satellites that require a high delta V, and as a secondary propulsion for larger spacecraft that require precision formation flying, disturbance rejection, or attitude control. To ensure desirable performance throughout the life of such missions, an advancement in the understanding of the plasma structure and behavior of miniature ring-cusp discharges is required. A research model was fabricated to provide a simplified experimental test bed for the analysis of the plasma discharge chamber of a miniature ion thruster. The plasma source allowed for spatially resolved measurements with a Langmuir probe along a meridian plane. Probe measurements yielded plasma density, electron temperature, and plasma potential data. The magnetic field strength was varied along with the discharge current to determine the plasma behavior under various conditions. The structure of the plasma properties were found to be independent of the discharge power under the proper scaling. It was concluded that weaker magnetic fields can improve the overall performance for ion thruster operation. To further analyze the experimental measurements, a framework was developed based on the magnetic field. A flux aligned coordinate system was developed to decouple the perpendicular and parallel plasma motion with respect to the magnetic field. This was done using the stream function and magnetic scalar potential. Magnetic formulae provided intuition on the field profiles dependence on magnet dimensions. The flux aligned coordinate system showed that the plasma was isopycnic along constant stream function values. This was used to develop an empirical relation suitable for estimating the spatial behavior and to determine the plasma volume and loss areas. The plasma geometry estimates were applied to a control volume

  18. Advanced research and development for plasma processing of polymers with combinatorial plasma-process analyzer

    International Nuclear Information System (INIS)

    Setsuhara, Yuichi; Cho, Ken; Takenaka, Kosuke; Shiratani, Masaharu; Sekine, Makoto; Hori, Masaru

    2010-01-01

    A plasma-process analyzer has been developed on the basis of combinatorial method, in which process examinations with continuous variations of plasma-process conditions can be carried out on a substrate holder with an inclined distribution of process parameters. Combinatorial plasma-process analyses have been demonstrated for examinations of plasma-polymer interactions in terms of etching characteristics and surface morphologies in order to show feasibility and effectiveness of the methodology as advanced research and development for next-generation plasma nano processes. The etching properties and surface morphologies have been investigated for polyethylene terephthalate (PET) films exposed to argon-oxygen mixture plasmas. The etching depth data obtained from three independent batches of the experiments showed universal and almost linear dependence with increasing product of (ion saturation current) x (exposure time); i.e. ion dose. Surface roughness of the polymer slightly increased with increasing ion dose, while the mean spacing after plasma exposure was found to decrease monotonically with increasing ion dose but was saturated at the level of approximately 250 nm.

  19. PREFACE: 11th Asia-Pacific Conference on Plasma Science and Technology (APCPST-11) and 25th Symposium on Plasma Science for Materials (SPSM-25)

    Science.gov (United States)

    Watanabe, Takayuki; Kaneko, Toshio; Sekine, Makoto; Tanaka, Yasunori

    2013-06-01

    The 11th Asia-Pacific Conference on Plasma Science and Technology (APCPST-11) was held in Kyoto, Japan on 2-5 October 2012 with the 25th Symposium on Plasma Science for Materials (SPSM-25). SPSM has been held annually since 1988 under the sponsorship of The 153rd Committee on Plasma Materials Science, Japan Society for the Promotion of Science (JSPS). This symposium is one of the major activities of the Committee, which is organized by researchers in academia and industry for the purpose of advancing intersectional scientific information exchange and discussion of science and technology of plasma materials processing. APCPST and SPSM are jointly held biennially to survey the current status of low temperature and thermal plasma physics and chemistry for industrial applications. The whole area of plasma processing was covered from fundamentals to applications. Previous meetings were held in China, Japan, Korea, and Australia, attended by scientists from the Asia-Pacific and other countries. The joint conference was organized in plenary lectures, invited, contributed oral presentations and poster sessions. At this meeting, we had 386 participants from 10 countries and 398 presentations, including 26 invited presentations. This year, we arranged special topical sessions that covered green innovation, life innovation, and technical reports from industry. This conference seeks to bring the plasma community together and to create a forum for discussing the latest developments and issues, the challenges ahead in the field of plasma research and applications among engineers and scientists in Asia, the Pacific Rim, as well as Europe. This volume presents 44 papers that were selected via a strict peer-review process from full papers submitted for the proceedings of the conference. The topics range from the basic physics and chemistry of plasma processing to a broad variety of materials processing and environmental applications. This volume offers an overview of recent

  20. Coil Tolerance Impact on Plasma Surface Quality for NCSX

    International Nuclear Information System (INIS)

    Brooks, Art; Reiersen, Wayne

    2003-01-01

    The successful operation of the National Compact Stellarator Experiment (NCSX) machine will require producing plasma configurations with good flux surfaces, with a minimum volume of the plasma lost to magnetic islands or stochastic regions. The project goal is to achieve good flux surfaces over 90% of the plasma volume. NCSX is a three period device designed to be operated with iota ranging from ∼0.4 on axis to ∼0.7 at the edge. The field errors of most concern are those that are resonant with 3/5 and 3/6 modes (for symmetry preserving field errors) and the 1/2 and 2/3 modes (for symmetry breaking field errors). In addition to losses inherent in the physics configuration itself, there will be losses from field errors arising from coil construction and assembly errors. Some of these losses can be recovered through the use of trim coils or correction coils. The impact of coil tolerances on plasma surface quality is evaluated herein for the NCSX design. The methods used in this evaluation are discussed. The ability of the NCSX trim coils to correct for field errors is also examined. The results are used to set coils tolerances for the various coil systems

  1. Review article: volume expansion in patients with cirrhosis

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Kiszka-Kanowitz, Marianne; Bendtsen, Flemming

    2002-01-01

    with low systemic vascular resistance, increased whole-body vascular compliance, and increased arterial compliance. The effectiveness and temporal relations of plasma/blood volume expansion depend highly on the type of load (water, saline, oncotic material, red blood cells). Patients with cirrhosis respond...... in advanced cirrhosis is qualitatively and quantitatively different from that of healthy subjects, and in those with early cirrhosis. Timely handling is essential, but difficult as it is a balance between the risks of excess extravascular volume loading and further circulatory dysfunction in these patients...

  2. Hematologic and plasma biochemical reference values in Indian peafowl (Pavo cristatus).

    Science.gov (United States)

    Samour, Jaime; Naldo, Jesus; Rahman, Habeeb; Sakkir, Mohammed

    2010-06-01

    Blood samples were collected from captive, adult, clinically normal Indian peafowl (Pavo cristatus) for hematologic and plasma biochemical analyses. Hematologic parameters investigated were total red blood cell count, hemoglobin, packed cell volume, fibrinogen, mean cell volume, mean cell hemoglobin, mean cell hemoglobin concentration, total white blood cell count, differential white blood cell count, and thrombocyte count. Plasma biochemical parameters investigated were alanine aminotransferase, alkaline phosphatase, amylase, aspartate aminotransferase, bile acids, total bilirubin, blood urea nitrogen, calcium, cholesterol, creatinine, creatine kinase, gamma glutamyltransferase, lactate dehydrogenase, glucose, iron, phosphorus, and uric acid, as well as plasma protein electrophoresis. Results were compared with values from studies done in houbara bustards (Chlamydotis undulata), kori bustards (Ardeotis kori), stone curlews (Burhinus oedicnemus), and taxonomically related species, including ring-necked pheasants (Phasianus colchicus), red-legged partridges (Alectoris rufa), Kashmir native fowl (Kashmirfavorella), and Bangladesh native, Fayoumi, and Assil fowl (Gallus domesticus).

  3. Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: analysis of human plasma and cerebrospinal fluid.

    Science.gov (United States)

    Hyung, Seok-Won; Piehowski, Paul D; Moore, Ronald J; Orton, Daniel J; Schepmoes, Athena A; Clauss, Therese R; Chu, Rosalie K; Fillmore, Thomas L; Brewer, Heather; Liu, Tao; Zhao, Rui; Smith, Richard D

    2014-11-01

    Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (depletion media can be prohibitive for larger-scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large-scale studies. We characterized the performance of a 346 μL column volume microscale depletion system, using four different flow rates to determine the most effective depletion conditions for ∼6-μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10-mL depletion column served as the control. Results showed depletion efficiency of the microscale column increased as flow rate decreased, and that our microdepletion was reproducible. In an initial application, a 600-μL sample of human cerebrospinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

  4. Electrostatic plasma lens for focusing negatively charged particle beams.

    Science.gov (United States)

    Goncharov, A A; Dobrovolskiy, A M; Dunets, S M; Litovko, I V; Gushenets, V I; Oks, E M

    2012-02-01

    We describe the current status of ongoing research and development of the electrostatic plasma lens for focusing and manipulating intense negatively charged particle beams, electrons, and negative ions. The physical principle of this kind of plasma lens is based on magnetic isolation electrons providing creation of a dynamical positive space charge cloud in shortly restricted volume propagating beam. Here, the new results of experimental investigations and computer simulations of wide-aperture, intense electron beam focusing by plasma lens with positive space charge cloud produced due to the cylindrical anode layer accelerator creating a positive ion stream towards an axis system is presented.

  5. Optimal Design of Magnetic ComponentsinPlasma Cutting Power Supply

    Science.gov (United States)

    Jiang, J. F.; Zhu, B. R.; Zhao, W. N.; Yang, X. J.; Tang, H. J.

    2017-10-01

    Phase-shifted transformer and DC reactor are usually needed in chopper plasma cutting power supply. Because of high power rate, the loss of magnetic components may reach to several kilowatts, which seriously affects the conversion efficiency. Therefore, it is necessary to research and design low loss magnetic components by means of efficient magnetic materials and optimal design methods. The main task in this paper is to compare the core loss of different magnetic material, to analyze the influence of transformer structure, winding arrangement and wire structure on the characteristics of magnetic component. Then another task is to select suitable magnetic material, structure and wire in order to reduce the loss and volume of magnetic components. Based on the above outcome, the optimization design process of transformer and dc reactor are proposed in chopper plasma cutting power supply with a lot of solutions. These solutions are analyzed and compared before the determination of the optimal solution in order to reduce the volume and power loss of the two magnetic components and improve the conversion efficiency of plasma cutting power supply.

  6. Interrelation between human fertility and seminal plasma lipids, prostaglandins and zinc

    International Nuclear Information System (INIS)

    Hafiez, A.A.; Zaki, K.; Abbas, E.Z.; Halawa, F.A.; Abdel-Azis, A.

    1986-01-01

    In adult fertile men (32), men with oligospermia (43) and men with azoospermia (31) seminal plasma lipids, prostaglandins (PG) and Zn were determined. The PGs were determined by radioimmunoassay. In oligospermia the seminal plasma levels of PGE phospholipids, triglycerides and Zn were significantly increased, while the PGF/sub 2α/ level was unchanged. In azoospermia the seminal plasma total lipids, phospholipids and cholesterol were significantly decreased, PGE revealed an insignificant decrease only

  7. Intense ion beam neutralization using underdense background plasma

    Energy Technology Data Exchange (ETDEWEB)

    Berdanier, William [Department of Physics, The University of Texas at Austin, Austin, Texas 78712 (United States); Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States); Roy, Prabir K. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Kaganovich, Igor [Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543 (United States)

    2015-01-15

    Producing an overdense background plasma for neutralization purposes with a density that is high compared to the beam density is not always experimentally possible. We show that even an underdense background plasma with a small relative density can achieve high neutralization of intense ion beam pulses. Using particle-in-cell simulations, we show that if the total plasma electron charge is not sufficient to neutralize the beam charge, electron emitters are necessary for effective neutralization but are not needed if the plasma volume is so large that the total available charge in the electrons exceeds that of the ion beam. Several regimes of possible underdense/tenuous neutralization plasma densities are investigated with and without electron emitters or dense plasma at periphery regions, including the case of electron emitters without plasma, which does not effectively neutralize the beam. Over 95% neutralization is achieved for even very underdense background plasma with plasma density 1/15th the beam density. We compare results of particle-in-cell simulations with an analytic model of neutralization and find close agreement with the particle-in-cell simulations. Further, we show experimental data from the National Drift Compression experiment-II group that verifies the result that underdense plasma can neutralize intense heavy ion beams effectively.

  8. Test accuracy of metabolic indicators in predicting decreased fertility in dairy cows

    DEFF Research Database (Denmark)

    Lomander, H; Gustafsson, H; Svensson, C

    2012-01-01

    Negative energy balance is a known risk factor for decreased fertility in dairy cows. This study evaluated the accuracy of plasma concentrations of nonesterified fatty acids (NEFA), β-hydroxybutyrate (BHBA), and insulin-like growth factor 1 (IGF-1)—factors related to negative energy balance...... was low when metabolic indicators measured as single values in early lactation were used to predict fertility in dairy cows, but accuracy was influenced by cow-level factors such as parity. The prevalence of the target condition (in this case, decreased fertility) also influences test usefulness......—in predicting decreased fertility. One plasma sample per cow was collected from 480 cows in 12 herds during the period from d 4 to 21 in milk and analyzed for NEFA, BHBA, and IGF-1. For each cow, data on breed, parity, calving date, gynecological examinations, and insemination dates were obtained. Milk samples...

  9. Adopting plasma pyrolysis for management of low-level solid radioactive waste in India

    International Nuclear Information System (INIS)

    Gupta, R.K.; Singh, A.K.; Yeotikar, R.G.; Patil, S.P.; Jha, Jyoti; Mishra, S.K.; Gandhi, K.G.; Misra, S.D.

    2010-01-01

    Since Plasma Pyrolysis of Low-Level Solid Radioactive Waste has the potential of reducing waste volumes by a factor of up to 1000:1, the new technology is seen as a sound engineering and economic option for managing voluminous low-active wastes. Development and adoption of such technique, to replace existing methods of Low-Level Solid Radioactive Waste management, is borne out of a compelling need to conserve disposal space. While Plasma-based systems are already in use for disposal of medical, toxic and other industrial wastes, the level of maturity is yet to be attained in their radioactive applications. A Prototype Plasma Pyrolysis Unit is being set up in India which, after extensive trials, will function as a full-scale plant for the volume reduction of Low-Level Solid Radioactive Wastes. This paper deals with the transition philosophy from the current techniques to the Plasma-based process. The design and engineering of the proposed facility and various system components is also briefly touched upon. (author)

  10. Measuring the equations of state in a relaxed magnetohydrodynamic plasma

    Science.gov (United States)

    Kaur, M.; Barbano, L. J.; Suen-Lewis, E. M.; Shrock, J. E.; Light, A. D.; Brown, M. R.; Schaffner, D. A.

    2018-01-01

    We report measurements of the equations of state of a fully relaxed magnetohydrodynamic (MHD) laboratory plasma. Parcels of magnetized plasma, called Taylor states, are formed in a coaxial magnetized plasma gun, and are allowed to relax and drift into a closed flux conserving volume. Density, ion temperature, and magnetic field are measured as a function of time as the Taylor states compress and heat. The theoretically predicted MHD and double adiabatic equations of state are compared to experimental measurements. We find that the MHD equation of state is inconsistent with our data.

  11. [Removal of high-abundance proteins in plasma of the obese by improved TCA/acetone precipitation method].

    Science.gov (United States)

    Wang, Jun; Feng, Liru; Yu, Wei; Xu, Jian; Yang, Hui; Liu, Xiaoli

    2013-09-01

    To develop an improved trichloroacetic acid (TCA)/acetone precipitation method for removal of high-abundance proteins in plasma of the obese. Volumes of TCA/acetone solution (1, 3, 4, 5, 6, 8, 10 and 20 times of the sample) and concentrations of TCA (10%, 30%, 50%, 60%, 70% TCA/acetone solution) have been investigated to optimize the conditions of sample preparation. SDS-PAGE were used to separate and tested proteins in the supernatant and sediment. The best concentration of the TCA/acetone solution was first determined by SDS-PAGE. The protein in precipitation from 10% TCA/acetone solution processing and the new determined concentration TCA/acetone solution processing were verified by 2-D-SDS-PAGE. And then the digested products of the protein in precipitation and supernatant by trypsin were analyzed by nano HPLC-Chip-MS/MS to verify which is the best concentration to process the plasma. The best volume of TCA/acetone is four times to sample, which less or more TCA/acetone would reduce the removal efficiency of high-abundance proteins. The concentration of TCA in acetone solution should be 60%, which may remove more high-abundance proteins in plasma than 10%, 30%, 50% TCA in acetone solution. If the TCA concentration is more than 60%, the reproducibility will be much poorer due to fast precipitation of proteins. The results of mass identification showed that human plasma prepared with 60% TCA/acetone (4 times sample volume) could be verified more low-abundance proteins than 10%. The most desirable conditions for removal of high-abundance proteins in plasma is 60% TCA/acetone (4 times sample volume), especially for the plasma of obesity.

  12. MHD instabilities and their effects on plasma confinement in the large helical device plasmas

    International Nuclear Information System (INIS)

    Toi, K.

    2002-01-01

    MHD stability of NBI heated plasmas and impacts of MHD modes on plasma confinement are intensively studied in the Large Helical Device (LHD). Three characteristic MHD instabilities were observed, that is, (1) pressure driven modes excited in the plasma edge, (2) pressure driven mode in the plasma core, and (3) Alfven eigenmodes (AEs) driven by energetic ions. MHD mode excited in the edge region accompanies multiple satellites, and is called Edge Harmonic Modes (EHMs). EHM sometimes has a bursting character. The bursting EHM transiently decreases the stored energy by about 15 percent. In the plasma core region, m=2/n=1 pressure driven mode is typically destabilized. The mode often induces internal collapse in the higher beta regime more than 1 percent. The internal collapse appreciably affects the global confinement. Energetic ion driven AEs are often detected in NBI-heated LHD plasmas. Particular AE with the frequency 8-10 times larger than TAE-frequency was detected in high beta plasmas more than 2 percent. The AE may be related to helicity-induced AE. Excitation of these three types of MHD instabilities and their impacts on plasma confinement are discussed. (author)

  13. Study on Laser Induced Plasma Produced in Liquid

    International Nuclear Information System (INIS)

    Tsuda, N.; Yamada, J.

    2003-01-01

    When an intense laser light is focused in liquid, a hot plasma is produced at the focal spot. The breakdown threshold and the transmittance of sodium choroids solution are observed using excimer laser or YAG laser. The breakdown threshold decreases with increasing NaCl concentration. Threshold intensity of plasma produced by YAG laser is lower than excimer laser. The behavior of plasma development is observed by a streak camera. The plasma produced by a YAG laser develops only backward. However, the plasma produced by excimer laser develops not only backward but also forward same as the plasma development in high-pressure gases

  14. On helicon wave induced radial plasma transport

    International Nuclear Information System (INIS)

    Petrzilka, V.

    1993-04-01

    Estimates of helicon wave induced radial plasma transport are presented. The wave induced transport grows or decreases in dependence on the sign of the azimuthal wave number; these changes in transport may play an important role in helicon wave plasma sources. (author) 5 figs., 18 refs

  15. Numerical simulation of a DC double anode arc plasma torch

    International Nuclear Information System (INIS)

    Chen Lunjiang; Tang Deli; Zhu Hailong

    2012-01-01

    A 2D axisymmetric numerical simulation of DC double anode plasma torch was done by the computational fluid dynamics (CFD) software FLUENT to improve the efficiency of the waste treatment, which is on the basis of the magnetic fluid dynamics (MHD) theory and uses the method of magnetic vector potential, and the simulation method is based on SIMPLE algorithm. The temperature and speed distributions of the plasma, and so on were obtained. The results show that the temperature of plasma decreases with increasing the axial distance, and increases with increasing the amplitude of the arc current. The velocity first increases and then decreases with the axial distance increase, and increase with the arc current increase. The temperature and the speed at the export of the plasma torch both decrease when the radial distance increases. Those results are in agreement with the experimental results. (authors)

  16. Production of a large diameter ECR plasma with low electron temperature

    International Nuclear Information System (INIS)

    Koga, Mayuko; Hishikawa, Yasuhiro; Tsuchiya, Hayato; Kawai, Yoshinobu

    2006-01-01

    A large diameter plasma over 300 mm in diameter is produced by electron cyclotron resonance (ECR) discharges using a cylindrical vacuum chamber of 400 mm in inner diameter. It is found that the plasma uniformity is improved by adding the nitrogen gas to pure Ar plasma. The electron temperature is decreased by adding the nitrogen gas. It is considered that the electron energy is absorbed in the vibrational energy of nitrogen molecules and the electron temperature decreases. Therefore, the adjunction of the nitrogen gas is considered to be effective for producing uniform and low electron temperature plasma

  17. Nocturnal polyuria and decreased serum testosterone: is there an association in men with lower urinary tract symptoms?

    Science.gov (United States)

    Kim, Jin Wook; Oh, Mi Mi; Yoon, Cheol Yong; Bae, Jae Hyun; Kim, Je Jong; Moon, Du Geon

    2014-05-01

    To investigate the putative association between nocturia and decreased serum testosterone in men with lower urinary tract symptoms. Frequency volume charts and serum testosterone levels of patients visiting the outpatient clinic for lower urinary tract symptoms were collected and analyzed. Age, prostate volume, body mass index and the presence of comorbidities were accounted for. Frequency volume charts were analyzed for pathophysiological components of nocturnal polyuria, global polyuria, decreased nocturnal bladder capacity and increased frequency to identify associated risks. Frequency volume charts were also used to chart 8-h changes of volume, frequency and capacity to identify time diurnal interactions with risk factors based on serum testosterone levels. A total of 2180 patients were enrolled in the study. Multivariate analysis showed testosterone decreased 0.142 ng/mL for every increase in nocturia, independent of other factors. Logistic regression analysis showed a significant difference between pathophysiological components. Decreased testosterone was shown to carry a significant independent risk for overall nocturia (odds ratio 1.60, 95% confidence interval 1.013-2.527, P = 0.044), and particularly nocturnal polyuria (odds ratio 1.934, 95% confidence interval 1.001-3.737, P = 0.027). Repeated measurement models showed patients with serum testosterone below 2.50 ng/mL to have a paradoxical increase in nocturnal urine volume at night. Nocturia, especially nocturnal polyuria, is associated with decreased serum testosterone. Patients with low serum testosterone show increased nocturnal urine output. © 2013 The Japanese Urological Association.

  18. Quartz-crystal microbalance study for characterizing atomic oxygen in plasma ash tools

    International Nuclear Information System (INIS)

    Srivastava, A.K.; Sakthivel, P.

    2001-01-01

    This article discusses the measurement of atomic oxygen (AO) concentrations in an oxygen discharge using a quartz-crystal microbalance (QCM). This is a device that has been previously used for monitoring thin-film deposition, among several other applications. The sensor consists of a silver-coated quartz crystal that oscillates at its specific resonant frequency (typically, at about 6 MHz), which is dependent on the mass of the crystal. When exposed to AO, the silver oxidizes rapidly, resulting in a change in its mass, and a consequent change in this frequency. The frequency change is measured with a counter, and when plotted versus time, it may be fit to a standard diffusion-limited oxide-growth model. This model is then used to determine the specific AO flux to the crystal, and by inference, to the wafer. Initial results of QCM measurements in the FusionGemini Plasma Asher (GPL TM -standard downstream microwave asher) and FusionGemini Enhanced Strip (GES TM -fluorine compatible enhanced strip asher) are presented in this article. The results indicate AO densities of the order of 10 12 cm -3 on the wafer. There is a marked increase in AO concentration with addition of nitrogen into the plasma, and a decrease in AO concentration with increasing pressure at constant flow. Effects of increasing the total plasma volume in the enhanced strip tool on AO production are discussed

  19. Atomic and molecular processes in fusion plasmas

    International Nuclear Information System (INIS)

    Kato, Daiji; Nakamura, Nobuyuki

    2013-01-01

    One of important issues concerning steady state sustainment of magnetically confined plasmas (MCPs) is distribution of impurity ions in the MCPs and radiation powers by the ions. Since tungsten divertors will be used in ITER, the primary element of heavy impurity ions would be tungsten. Tungsten cannot be fully ionized even in core plasmas of ITER. Line radiations by bound electrons of the tungsten ions following electron impact excitations decrease temperatures of the core plasmas. Thus, it is required to keep tungsten concentration in the core plasmas as small as possible. (J.P.N.)

  20. Collisionality dependent transport in TCV SOL plasmas

    DEFF Research Database (Denmark)

    Garcia, Odd Erik; Pitts, R.A.; Horacek, J.

    2007-01-01

    Results are presented from probe measurements in the low field side scrape-off layer (SOL) region of TCV during plasma current scan experiments. It is shown that with decreasing plasma current the radial particle density profile becomes broader and the fluctuation levels and turbulence driven...... radial particle flux increase. In the far SOL the fluctuations exhibit a high degree of statistical similarity and the particle density and flux at the wall radius scale inversely with the plasma current. Together with previous TCV density scan experiments, this indicates that plasma fluctuations...