WorldWideScience

Sample records for plant-incorporated protectants

  1. 40 CFR 174.525 - E. coli B-D-glucuronidase enzyme as a plant-incorporated protectant inert ingredient; exemption...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false E. coli B-D-glucuronidase enzyme as a... E. coli B-D-glucuronidase enzyme as a plant-incorporated protectant inert ingredient; exemption from the requirement of a tolerance. Residues of E. coli B-D-glucuronidase enzyme are exempt from the...

  2. Plant dynamics studies towards design of plant protection system for PFBR

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K., E-mail: natesan@igcar.gov.in [Nuclear and Safety Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Kasinathan, N.; Velusamy, K.; Selvaraj, P.; Chellapandi, P. [Nuclear and Safety Engineering Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Analysis of various design basis events in a fast breeder reactor towards design of plant protection system. Black-Right-Pointing-Pointer Plant dynamic modeling of a sodium cooled fast breeder reactor. Black-Right-Pointing-Pointer Selection of optimum set of plant parameters for considering best plant availability. - Abstract: Prototype fast breeder reactor (PFBR) is a 500 MWe (1250 MWt) liquid sodium cooled pool type reactor currently under construction in India. For a safe and efficient operation of the plant, it is necessary that the reactor is protected from all the transients that may occur in the plant. In order to accomplish this, adequate number of SCRAM parameters is required in the plant protection system with reliable instrumentation. For identifying the SCRAM parameters, the neutronic and thermal hydraulic responses of the plant for various possible events need to be established. Towards this, a one dimensional plant dynamics code DYANA-P has been developed with thermal hydraulic models for reactor core, hot and cold pools, intermediate heat exchangers, pipelines, steam generator, primary sodium circuits and secondary sodium circuits. The code also incorporates neutron kinetics and reactivity feedback models. By a comprehensive plant dynamics study an optimum list of SCRAM parameters and the maximum permissible response time for various instruments used for deriving them have been arrived at.

  3. System 80+{trademark} standard design incorporates radiation protection lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Crom, T.D.; Naugle, C.L. [Duke Engineering & Services, Inc., Charlotte, NC (United States); Turk, R.S. [ABB Combustion Engineering Nuclear Power, Windsor, CT (United States)

    1995-03-01

    Many lessons have been learned from the current generation of nuclear plants in the area of radiation protection. The following paper will outline how the lessons learned have been incorporated into the design and operational philosophy of the System 80+{trademark} Standard Design currently under development by ABB Combustion Engineering (ABB-CE) with support from Duke Engineering and Services, Inc. and Stone and Webster Engineering Corporation in the Balance-of-Plant design. The System 80+{trademark} Standard Design is a complete nuclear power plant for national and international markets, designed in direct response to utility needs for the 1990`s, and scheduled for Nuclear Regulatory Commission (NRC) Design Certification under the new standardization rule (10 CFR Part 52). System 80+{trademark} is a natural extension of System 80{sup R} technology, an evolutionary change based on proven Nuclear Steam Supply System (NSSS) in operation at Palo Verde in Arizona and under construction at Yonggwang in the Republic of Korea. The System 80+{trademark} Containment and much of the Balance of Plant design is based upon Duke Power Company`s Cherokee Plant, which was partially constructed in the late 1970`s, but, was later canceled (due to rapid declined in electrical load growth). The System 80+{trademark} Standard Design meets the requirements given in the Electric Power Research Institute (EPRI) Advanced Light Water Reactor (ALWR) Requirements Document. One of these requirements is to limit the occupational exposure to 100 person-rem/yr. This paper illustrates how this goal can be achieved through the incorporation of lessons learned, innovative design, and the implementation of a common sense approach to operation and maintenances practices.

  4. FPGA-Based Plant Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae [KEPCO E and C, Daejeon (Korea, Republic of)

    2011-08-15

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system.

  5. FPGA-Based Plant Protection System

    International Nuclear Information System (INIS)

    Lee, Yoon Hee; Ha, Jae Hong; Kim, Hang Bae

    2011-01-01

    This paper relates to a plant protection system which detects non-permissible conditions and determines initiation of protective actions for nuclear power plants (NPPs). Conventional plant protection systems were designed based on analog technologies. It is well known that existing protection systems for NPPs contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance and repair for analog-based plant protection systems may be difficult as analog parts become obsolete or difficult to obtain. Accordingly, as an alternative to the analog technology, the digitalisation of the plant protection system was required. Recently digital plant protection systems which include programmable logic controllers (PLCs) and/or computers have been introduced. However PLC or computer-based plant protection systems use an operating system and application software, and so they may result in a common mode failure when a problem occurs in the operating system or application software. Field Programmable Gate Arrays (FPGAs) are highlighted as an alternative to conventional protection or control systems. The paper presents the design of a four-channel plant protection system whose protection functions are implemented in FPGAs without any central processing unit or operating system

  6. 77 FR 12284 - Access to Confidential Business Information; Protection Strategies Incorporated

    Science.gov (United States)

    2012-02-29

    ... Business Information; Protection Strategies Incorporated AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY: EPA has authorized its contractor, Protection Strategies Incorporated (PSI) of... Business Information (CBI). DATES: Access to the confidential data occurred on or about February 16, 2012...

  7. Fire protection of nuclear power plant cable ducts

    International Nuclear Information System (INIS)

    Kandrac, J.; Lukac, L.

    1987-01-01

    Fire protection of cable ducts in the Bohunice and Dukovany V-2 nuclear power plants is of a fourtier type. The first level consists in preventive measures incorporated in the power plant design and layout. The second level consists in early detection and a quick repressive action provided by an electric fire alarm system and a stationary spray system, respectively. Fire partitions and glands represent the third level while special spray, paint and lining materials represent the fourth level of the protection. Briefly discussed are the results of an analysis of the stationary spray system and the effects reducing the efficiency of a fire-fighting action using this system. The analysis showed the need of putting off cable duct fires using mobile facilities in case the stationary spray system cannot cope any longer. (Z.M.). 3 figs., 2 refs

  8. Incorporation of mammalian actin into microfilaments in plant cell nucleus

    Directory of Open Access Journals (Sweden)

    Paves Heiti

    2004-04-01

    Full Text Available Abstract Background Actin is an ancient molecule that shows more than 90% amino acid homology between mammalian and plant actins. The regions of the actin molecule that are involved in F-actin assembly are largely conserved, and it is likely that mammalian actin is able to incorporate into microfilaments in plant cells but there is no experimental evidence until now. Results Visualization of microfilaments in onion bulb scale epidermis cells by different techniques revealed that rhodamine-phalloidin stained F-actin besides cytoplasm also in the nuclei whereas GFP-mouse talin hybrid protein did not enter the nuclei. Microinjection of fluorescently labeled actin was applied to study the presence of nuclear microfilaments in plant cells. Ratio imaging of injected fluorescent rabbit skeletal muscle actin and phalloidin staining of the microinjected cells showed that mammalian actin was able to incorporate into plant F-actin. The incorporation occurred preferentially in the nucleus and in the perinuclear region of plant cells whereas part of plant microfilaments, mostly in the periphery of cytoplasm, did not incorporate mammalian actin. Conclusions Microinjected mammalian actin is able to enter plant cell's nucleus, whereas incorporation of mammalian actin into plant F-actin occurs preferentially in the nucleus and perinuclear area.

  9. 76 FR 69722 - Access to Confidential Business Information by Protection Strategies Incorporated

    Science.gov (United States)

    2011-11-09

    ... Business Information by Protection Strategies Incorporated AGENCY: Environmental Protection Agency (EPA... Control Act (TSCA) confidential business information and to provide notice that this contract has been extended until December 31, 2011. Protection Strategies Incorporated (PSI) has been the owner of Eagle...

  10. 48 CFR 252.217-7016 - Plant protection.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Plant protection. 252.217... Clauses 252.217-7016 Plant protection. As prescribed in 217.7104(a), use the following clause: Plant Protection (DEC 1991) (a) The Contractor shall provide, for the plant and work in process, reasonable...

  11. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  12. Incorporation of plant materials in the control of root pathogens in muskmelon

    Directory of Open Access Journals (Sweden)

    Andréa Mirne de Macêdo Dantas

    2013-12-01

    Full Text Available The effect of plant materials[Sunn Hemp (Crotalaria juncea, Castor Bean (Ricinus communis L., Cassava (Manihot esculenta Crantz and Neem (Azadirachta indica] and the times of incorporation of these materials in regards to the incidence of root rot in melon was evaluated in Ceará state, Brazil. The experiment was conducted in a commercial area with a history of root pathogens in cucurbitaceae. The randomized block design was used, in a 5 x 3 factorial arrangement with four repetitions. The treatments consisted of a combination of four plant materials (sunn hemp, castor beans, cassava and neem and a control with no soil incorporation of plant material and three times of incorporation (28, 21, and 14 days before the transplanting of the seedlings. Lower incidence of root rot was observed in practically all of the treatments where materials were incorporated at different times, with variation between the materials, corresponding with the time of incorporation, in relation to the soil without plant material. The pathogens isolated from the symptomatic muskmelon plants were Fusarium solani, Macrophomina phaseolina, Monosporascus cannonballus and Rhizoctonia solani, F. solani being encountered most frequently.

  13. Environmental protection in thermal power plants

    International Nuclear Information System (INIS)

    1987-01-01

    This workbook is a compilation of the most important facts and data that are relevant today for environmental protection in thermal power plants. Unlike the other issues the text is not in the form of a random collection of data but in the form of a complete presentation. Possible elaboration projects for pupils can be easily derived from the individual sections. These deal with: the discussion about environmental protection; forest decline; sources of emission; nuisances in the Federal Republic of Germany; environmental protection in fossil-fuel power plants - clean air - cooling water utilization and water protection - noise; environmental protection in nuclear power plants - radioactive material produced in nuclear reactors and the retention of such materials - radioactive waste materials - monitoring of radioactive emissions; accessory materials and hints. (orig./HSCH) [de

  14. Fire protection at nuclear power plants

    International Nuclear Information System (INIS)

    1999-11-01

    The guide presents specific requirements for the design and implementation of fire protection arrangements at nuclear power plants and for the documents relating to the fire protection that are to be submitted to STUK (Finnish Radiation and Nuclear Safety Authority). Inspections of the fire protection arrangements to be conducted by STUK during the construction and operation of the power plants are also described in this guide. The guide can also be followed at other nuclear facilities

  15. Wind Plant Collector System Fault Protection and Coordination

    Energy Technology Data Exchange (ETDEWEB)

    Bradt, M. [IEEE PES Wind Plant Collector System Design Working Group; Behnke, M. R. [IEEE PES Wind Plant Collector System Design Working Group; Bloethe, W.G. [IEEE PES Wind Plant Collector System Design Working Group; Brooks, C. [IEEE PES Wind Plant Collector System Design Working Group; Camm, E H [IEEE PES Wind Plant Collector System Design Working Group; Dilling, W. [IEEE PES Wind Plant Collector System Design Working Group; Goltz, B. [IEEE PES Wind Plant Collector System Design Working Group; Li, J. [IEEE PES Wind Plant Collector System Design Working Group; Niemira, J. [IEEE PES Wind Plant Collector System Design Working Group; Nuckles, K. [IEEE PES Wind Plant Collector System Design Working Group; Patino, J. [IEEE PES Wind Plant Collector System Design Working Group; Reza, M [IEEE PES Wind Plant Collector System Design Working Group; Richardson, B. [IEEE PES Wind Plant Collector System Design Working Group; Samaan, N. [IEEE PES Wind Plant Collector System Design Working Group; Schoene, Jens [IEEE PES Wind Plant Collector System Design Working Group; Smith, Travis M [ORNL; Snyder, Isabelle B [ORNL; Starke, Michael R [ORNL; Walling, R. [IEEE PES Wind Plant Collector System Design Working Group; Zahalka, G. [IEEE PES Wind Plant Collector System Design Working Group

    2010-01-01

    This paper presents a summary of the most important protection and coordination considerations for wind power plants. Short-circuit characteristics of both aggregate wind plant and individual wind turbine genera- tors, as well as general interconnection protection requirements are discussed. Many factors such as security, reliability, and safety are considered for proper conservative protection of the wind power plant and individual turbines.

  16. Protected-area boundaries as filters of plant invasions.

    Science.gov (United States)

    Foxcroft, Llewellyn C; Jarošík, Vojtěch; Pyšek, Petr; Richardson, David M; Rouget, Mathieu

    2011-04-01

    Human land uses surrounding protected areas provide propagules for colonization of these areas by non-native species, and corridors between protected-area networks and drainage systems of rivers provide pathways for long-distance dispersal of non-native species. Nevertheless, the influence of protected-area boundaries on colonization of protected areas by invasive non-native species is unknown. We drew on a spatially explicit data set of more than 27,000 non-native plant presence records for South Africa's Kruger National Park to examine the role of boundaries in preventing colonization of protected areas by non-native species. The number of records of non-native invasive plants declined rapidly beyond 1500 m inside the park; thus, we believe that the park boundary limited the spread of non-native plants. The number of non-native invasive plants inside the park was a function of the amount of water runoff, density of major roads, and the presence of natural vegetation outside the park. Of the types of human-induced disturbance, only the density of major roads outside the protected area significantly increased the number of non-native plant records. Our findings suggest that the probability of incursion of invasive plants into protected areas can be quantified reliably. ©2010 Society for Conservation Biology.

  17. Fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    1992-01-01

    The Code on Design (Safety Series 50-C-D (Rev. 1)) within the NUSS (Nuclear Safety Standards) programme of the IAEA points out the necessity of measures for protecting plant items which are important to safety against fires of internal and external origin. Experience of the past two decades in the operation of nuclear power plants and modern analysis techniques confirm that fire may be a real threat to nuclear safety and should receive adequate attention from the beginning of the design process throughout the life of the plant. Within the framework of the NUSS programme, a Safety Guide on fire protection had therefore been developed to enlarge on the general requirements given in the Code. Since its first publication in 1979, there has been considerable development in protection technology and analysis methods and after the Chernobyl accident it was decided to revise the existing Guide. The present Safety Guide is intended to advise designers, safety assessors and regulators on the concept of fire protection in the design of nuclear power plants and on recommended ways of implementing the concept in some detail in practice. Figs, 1 tab

  18. Protection of warehouses and plants under capacity constraint

    International Nuclear Information System (INIS)

    Bricha, Naji; Nourelfath, Mustapha

    2015-01-01

    While warehouses may be subjected to less protection effort than plants, their unavailability may have substantial impact on the supply chain performance. This paper presents a method for protection of plants and warehouses against intentional attacks in the context of the capacitated plant and warehouses location and capacity acquisition problem. A non-cooperative two-period game is developed to find the equilibrium solution and the optimal defender strategy under capacity constraints. The defender invests in the first period to minimize the expected damage and the attacker moves in the second period to maximize the expected damage. Extra-capacity of neighboring functional plants and warehouses is used after attacks, to satisfy all customers demand and to avoid the backorders. The contest success function is used to evaluate success probability of an attack of plants and warehouses. A numerical example is presented to illustrate an application of the model. The defender strategy obtained by our model is compared to the case where warehouses are subjected to less protection effort than the plants. This comparison allows us to measure how much our method is better, and illustrates the effect of direct investments in protection and indirect protection by warehouse extra-capacities to reduce the expected damage. - Highlights: • Protection of warehouses and plants against intentional attacks. • Capacitated plant and warehouse location and capacity acquisition problem. • A non-cooperative two-period game between the defender and the attacker. • A method to evaluate the utilities and determine the optimal defender strategy. • Using warehouse extra-capacities to reduce the expected damage

  19. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  20. Radio protective effects of some medicinal plants

    International Nuclear Information System (INIS)

    Barupal, G.K.

    2012-01-01

    Many plants are known to have beneficial therapeutic effects as noted in the traditional Indian system of medicine, Ayurveda and used since time immemorial for curing diseases. Even today, nearly 70% of the world's population is dependent on plants for handling their health related problems and plants have been utilized successfully for the treatment of free radical-mediated diseases in human such as Rheumatoid arthritis, Atherosclerosis, Cancer, Alzheimer's disease, Parkinson's disease, aging and several other conditions including inflammatory diseases. Plant extracts eliciting radio protective efficacy contain a plethora of compounds including antioxidants, immunostimulants, cell proliferation stimulators, anti-inflammatory and antimicrobial agent, some of which may act in isolation as well as in combination with other constituents from the same plants. Glycyrrhiza glabra, Allium sepa, Allium sativum, Aloe arborescens, Amaranthus paniculatus, Curcuma longa, Moringa olefera and Syzygium cumini are some important radio protective plants. Alium sativum has been reported to possess antioxidant antimicrobial, antitumor, antimutagenic and anti-inflammatory properties. Aloe arborescens acts as a cell proliferate, healer and allergy reducer. Amaranthus paniculatus is used for purifying blood and treating scrofulous sores. Curcuma longa is widely used in antitumor and antibacterial activities. Leaf extract of Moringa oleifera is significantly used in nervous debility and healing of wound. Chlorella is well known nutrient dense superfood that contains 60% protein, 18 amino acids (including all the essential amino acids), more than 20 vitamins and minerals. Chlorell has been used to treat cancer and also protect the body from the effects of cancer radiation treatment due to its chlorophyll in abundance level. However they have little attention for their radio protective as well as antioxidant. There is an urgent need to develop newer, more efficient and reliable bioassays

  1. Fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    1979-01-01

    The Safety Guide gives design and some operational guidance for protection from fire and fire-related explosions in nuclear power plants (NPP). It confines itself to fire protection of items important to safety, leaving the aspects of fire protection not related to safety in NPP to be decided upon the basis of the national practices and regulations

  2. Possibilities of Botanical Insecticides in Plant Protection

    Czech Academy of Sciences Publication Activity Database

    Pavela, R.; Sajfrtová, Marie; Sovová, Helena; Bárnet, M.

    2008-01-01

    Roč. 2, č. 1 (2008), s. 16-23 ISSN 1313-2563 Grant - others:MŠk(CZ) 2B08049 Institutional support: RVO:67985858 Keywords : botanical insecticides * plant extracts * supercritical fluid extraction Subject RIV: GF - Plant Pathology, Vermin, Weed, Plant Protection

  3. Protection of nuclear power plants against external events

    International Nuclear Information System (INIS)

    Kinet, P.; Roch, R.

    1978-01-01

    The paper describes the methodology of the safety design of nuclear power plants against external events with particular emphasis of the Belgian Plants. The site analysis and potential hazards evaluation are explained. The different designs incorporating various combinations of reinforced structures and dedicated systems are analysed. The particular lay-out and systems of the Belgian Plants are explained. (author)

  4. Inventory of cassava plant protection and development projects in ...

    African Journals Online (AJOL)

    A total of 303 cassava protection and development projects were identified of which about half are plant protection-oriented. Most activities on cassava protection have been centred on biological control and host plant resistance. The least activity has been on chemical control. The applicability of the collected database is ...

  5. Protection of nuclear power plants against external events

    International Nuclear Information System (INIS)

    Suetterlin, L.

    1978-01-01

    The different aspects for the selection of external events to be accounted for in designing nuclear power plants and in defining load assumptions are illustrated: 1) In case of earthquake the severest possible events according to the state of science and technology are assumed. 2) For events where it is not or only to a certain extent possible to apply this method, e.g. in the load case airplane crash, load assumptions are defined in a combined probabilitic-deterministic way. By the example of plant protection, it is shown that by integrating all measures for protecting against interference of third parties (sabotage) or other external events, optimum protection concepts may be achieved. In all considerations on interference of third parties or other external events, one has to take into account that absolute protection is not possible. Nevertheless, it may be confirmed that nuclear power plants not only have a much higher level of protection than other, non-nuclear plants with equal or even higher potential hazard, but also that they meet the requirement not to increase significantly the current risk of society. (orig./HP) [de

  6. High-temperature gas-cooled reactor steam-cycle/cogeneration lead plant. Plant Protection and Instrumentation System design description

    International Nuclear Information System (INIS)

    1983-01-01

    The Plant Protection and Instrumentation System provides plant safety system sense and command features, actuation of plant safety system execute features, preventive features which maintain safety system integrity, and safety-related instrumentation which monitors the plant and its safety systems. The primary function of the Plant Protection and Instrumentation system is to sense plant process variables to detect abnormal plant conditions and to provide input to actuation devices directly controlling equipment required to mitigate the consequences of design basis events to protect the public health and safety. The secondary functions of the Plant Protection and Instrumentation System are to provide plant preventive features, sybsystems that monitor plant safety systems status, subsystems that monitor the plant under normal operating and accident conditions, safety-related controls which allow control of reactor shutdown and cooling from a remote shutdown area

  7. Possibilities of Botanical Insecticides in Plant Protection

    Czech Academy of Sciences Publication Activity Database

    Pavela, R.; Sajfrtová, Marie; Sovová, Helena; Bárnet, M.

    2008-01-01

    Roč. 2, č. 1 (2008), s. 16-23 ISSN 1313-2563 Grant - others:GA MŠMT(CZ) 2B08049 Institutional research plan: CEZ:AV0Z40720504 Keywords : botanical insecticides * plant exctracts * supercritical fluid extraction Subject RIV: GF - Plant Pathology, Vermin, Weed, Plant Protection

  8. Fire protection maintenance at Browns Ferry Nuclear Plant

    International Nuclear Information System (INIS)

    Kern, J.R.

    1989-01-01

    This paper describes two approaches to staffing and organizing a fire protection maintenance group. Both have been used at Browns Ferry Nuclear Plant. One takes traditional craft functions and relocates them from the plant maintenance department to the fire protection section. The other expands the role to include response to fire, medical, and hazardous material emergencies. Both approaches remove the fire protection supervisor from a purely staff role, and involve him/her in direct-line management functions. This results in improved technical direction to the craftsmen, improved quality of the work performed, and improved craft morale. It also assures the fire protection supervisor of much more detailed knowledge of the overall status of the fire protection systems

  9. Fires: what plant locations should we really protect

    International Nuclear Information System (INIS)

    Berry, D.L.

    1980-01-01

    A fire protection analysis technique was developed from earlier work involving the protection of nuclear power plants against acts of sabotage. Characteristics unique to fire phenomena were used to modify the sabotage analysis methodology. These characteristics include the effects of fuel loads, ventilation rates, heat loss areas, barrier ratings, and plant locations. The new fire analysis technique was applied to an example nuclear power plant having 85 different plant areas. It was found that some safety and nonsafety areas were both highly vulnerable to fire spread and important to overall safety, while other areas were found to be of marginal importance to fire safety

  10. Importance of plants in radiation protection

    International Nuclear Information System (INIS)

    Rawat, Shalini

    2015-01-01

    Radioactive substances from nuclear programme structures are one of the major toxicant causing serious health hazards. These manmade radiations include X-ray machines radioactive fall-outs, nuclear reactor waste, TV, computers etc. Effect of radiation may be somatic and genetic. Most genetic effects are brought by manmade radiations. Plants on one hand using the electromagnetic radiation from sun for one of the most important vital activity of earth called Photosynthesis and on the other hand protecting us from harmful radiations. There are however, many natural compounds with radio-protective activity. Such compounds include sulfhydryl-containing compounds and anti-oxidant nutrients such as vitamins C and E, beta-carotene, N-acetylcysteine and selenium, along with a range of phytochemicals found in plants such as Ginkgo biloba, Vitis vinifera (Grape), Ocimum sanctum (Tulsi or holy basil). Some plants have capacity to absorb harmful radiation of computers like Aloe, Cactus, etc. Such study can be helpful in minimizing radiation pollution. Present review paper emphasizing Botanical, Ecological and Economic aspects of some plants. (author)

  11. Human Factors Engineering Incorporated into the Carolina Power and Light company's nuclear power plant control panel modifications

    International Nuclear Information System (INIS)

    Beith, D.M.; Shoemaker, E.M.; Horn, K.; Boush, D.

    1988-01-01

    Maintaining human factors conventions/practices that were established during the Detailed Control Design Review (DCRDR), is difficult if Human Factors Engineering (HFE) is not incorporated into the plant modification process. This paper presents the approach used at Carolina Power and Light's nuclear power plants that has successfully incorporated human factors engineering into their plant modification process. An HFE Design Guide or HFE Specification was developed which is used by the design engineers or plant engineering support groups in the preparation of plant modifications

  12. Public Lakes, Private Lakeshore: Modeling Protection of Native Aquatic Plants

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.

    2013-07-01

    Protection of native aquatic plants is an important proenvironmental behavior, because plant loss coupled with nutrient loading can produce changes in lake ecosystems. Removal of aquatic plants by lakeshore property owners is a diffuse behavior that may lead to cumulative impacts on lake ecosystems. This class of behavior is challenging to manage because collective impacts are not obvious to the actors. This paper distinguishes positive and negative beliefs about aquatic plants, in models derived from norm activation theory (Schwartz, Adv Exp Soc Psychol 10:221-279, 1977) and the theory of reasoned action (Fishbein and Ajzen, Belief, attitude, intention, and behavior: an introduction to theory and research, Addison-Wesley, Boston 1975), to examine protection of native aquatic plants by Minnesota lakeshore property owners. We clarify how positive and negative evaluations of native aquatic plants affect protection or removal of these plants. Results are based on a mail survey ( n = 3,115). Results suggest that positive evaluations of aquatic plants (i.e., as valuable to lake ecology) may not connect with the global attitudes and behavioral intentions that direct plant protection or removal. Lakeshore property owners' behavior related to aquatic plants may be driven more by tangible personal benefits derived from accessible, carefully managed lakeshore than intentional action taken to sustain lake ecosystems. The limited connection of positive evaluations of aquatic plants to global attitudes and behavioral intentions may reflect either lack of knowledge of what actions are needed to protect lake health and/or unwillingness to lose perceived benefits derived from lakeshore property.

  13. Public lakes, private lakeshore: Modeling protection of native aquatic plants

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.

    2013-01-01

    Protection of native aquatic plants is an important proenvironmental behavior, because plant loss coupled with nutrient loading can produce changes in lake ecosystems. Removal of aquatic plants by lakeshore property owners is a diffuse behavior that may lead to cumulative impacts on lake ecosystems. This class of behavior is challenging to manage because collective impacts are not obvious to the actors. This paper distinguishes positive and negative beliefs about aquatic plants, in models derived from norm activation theory (Schwartz, Adv Exp Soc Psychol 10:221–279, 1977) and the theory of reasoned action (Fishbein and Ajzen, Belief, attitude, intention, and behavior: an introduction to theory and research, Addison-Wesley, Boston 1975), to examine protection of native aquatic plants by Minnesota lakeshore property owners. We clarify how positive and negative evaluations of native aquatic plants affect protection or removal of these plants. Results are based on a mail survey (n = 3,115). Results suggest that positive evaluations of aquatic plants (i.e., as valuable to lake ecology) may not connect with the global attitudes and behavioral intentions that direct plant protection or removal. Lakeshore property owners’ behavior related to aquatic plants may be driven more by tangible personal benefits derived from accessible, carefully managed lakeshore than intentional action taken to sustain lake ecosystems. The limited connection of positive evaluations of aquatic plants to global attitudes and behavioral intentions may reflect either lack of knowledge of what actions are needed to protect lake health and/or unwillingness to lose perceived benefits derived from lakeshore property.

  14. Screening agrochemicals as potential protectants of plants against ozone phytotoxicity

    International Nuclear Information System (INIS)

    Saitanis, Costas J.; Lekkas, Dimitrios V.; Agathokleous, Evgenios; Flouri, Fotini

    2015-01-01

    We tested seven contemporary agrochemicals as potential plant protectants against ozone phytotoxicity. In nine experiments, Bel-W3 tobacco plants were experienced weekly exposures to a) 80 nmol mol −1 of ozone-enriched or ozone-free air in controlled environment chambers, b) an urban air polluted area, and c) an agricultural-remote area. Ozone caused severe leaf injury, reduced chlorophylls' and total carotenoids' content, and negatively affected photosynthesis and stomatal conductance. Penconazole, (35% ± 8) hexaconazole (28% ± 5) and kresoxim-methyl (28% ± 15) showed higher plants’ protection (expressed as percentage; mean ± s.e.) against ozone, although the latter exhibited a high variability. Azoxystrobin (21% ± 15) showed lower protection efficacy and Benomyl (15% ± 9) even lower. Trifloxystrobin (7% ± 11) did not protect the plants at all. Acibenzolar-S-methyl + metalaxyl-M (Bion MX) (−6% ± 17) exhibited the higher variability and contrasting results: in some experiments it showed some protection while in others it intensified the ozone injury by causing phytotoxic symptoms on leaves, even in control plants. - Highlights: • Penconazole and hexaconazole offered some protection to plants against ozone. • Bion MX fungicide caused phytotoxic symptoms to Bel-W3 tobacco plants. • Stomatal conductance was reduced in ozone-fumigated plants. - Seven agrochemicals were assessed as potential protectants against ozone phytotoxicity – triazoles fungicides were the most effective

  15. Screening agrochemicals as potential protectants of plants against ozone phytotoxicity.

    Science.gov (United States)

    Saitanis, Costas J; Lekkas, Dimitrios V; Agathokleous, Evgenios; Flouri, Fotini

    2015-02-01

    We tested seven contemporary agrochemicals as potential plant protectants against ozone phytotoxicity. In nine experiments, Bel-W3 tobacco plants were experienced weekly exposures to a) 80 nmol mol(-1) of ozone-enriched or ozone-free air in controlled environment chambers, b) an urban air polluted area, and c) an agricultural-remote area. Ozone caused severe leaf injury, reduced chlorophylls' and total carotenoids' content, and negatively affected photosynthesis and stomatal conductance. Penconazole, (35% ± 8) hexaconazole (28% ± 5) and kresoxim-methyl (28% ± 15) showed higher plants' protection (expressed as percentage; mean ± s.e.) against ozone, although the latter exhibited a high variability. Azoxystrobin (21% ± 15) showed lower protection efficacy and Benomyl (15% ± 9) even lower. Trifloxystrobin (7% ± 11) did not protect the plants at all. Acibenzolar-S-methyl + metalaxyl-M (Bion MX) (-6% ± 17) exhibited the higher variability and contrasting results: in some experiments it showed some protection while in others it intensified the ozone injury by causing phytotoxic symptoms on leaves, even in control plants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Particular features of fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    Krueger, W.

    1985-01-01

    The particular features of fire protection in nuclear power plants that are connected with the need to ensure nuclear and radiation safety even during an emergency are outlined followed by the recommendation to lay them down in special fire protection standards. These, in conjunction with comprehensive fire hazard analyses, could serve to work out complex concepts for the fire protection of individual nuclear power plants. Such concepts would be very useful for review and assessment of the fire protection design during the licensing process and for later inspections. (author)

  17. Research directions in plant protection chemistry

    Directory of Open Access Journals (Sweden)

    Andras Szekacs

    2017-09-01

    Full Text Available This Opinion paper briefly summarizes the views of the authors on the directions of research in the area of plant protection chemistry. We believe these directions need to focus on (1 the discovery of new pesticide active ingredients, and (2 the protection of human health and the environment. Research revenues are discussed thematically in topics of target site identification, pesticide discovery, environmental aspects, as well as keeping track with the international trends. The most fundamental approach, target site identification, covers both computer-aided molecular design and research on biochemical mechanisms. The discovery of various classes of pesticides is reviewed including classes that hold promise to date, as well as up-to-date methods of innovation, e.g. utilization of plant metabolomics in identification of novel target sites of biological activity. Environmental and ecological aspects represent a component of increasing importance in pesticide development by emphasizing the need to improve methods of environmental analysis and assess ecotoxicological side-effects, but also set new directions for future research. Last, but not least, pesticide chemistry and biochemistry constitute an integral part in the assessment of related fields of plant protection, e.g. agricultural biotechnology, therefore, issues of pesticide chemistry related to the development and cultivation of genetically modified crops are also discussed.

  18. Protection Ability Comparison of Several Mosquito Repellent Lotion Incorporated with Essential Oils of Mosquito Repellent Plants

    Directory of Open Access Journals (Sweden)

    Pramono Putro Utomo

    2014-12-01

    Full Text Available Most mosquito repellent lotions available on the market today contain the active ingredient diethyltoluamide (DEET which is very harmful to the skin. Natural mosquito repellent research using various essential oils (geranium oil, lemon oil, citronella oil and lavender oil as the active ingredient and the addition of aloe vera gel as a moisturizer has been done on a laboratory scale. The purpose of this study was to compare the protection ability of the mosquito repellent plants in Indonesia. The results showed that geranium oil, lemongrass oil, lavender oil and lemon oil could act as mosquito repellent. Best lotion formula all containing 15% essential oils have the effectiveness above 50% until the sixth hour were geranium oil, citronella oil and lavender oil while lemon oil only giving effectiveness above 50% until the second hour.

  19. Dehydrins Impart Protection against Oxidative Stress in Transgenic Tobacco Plants.

    Science.gov (United States)

    Halder, Tanmoy; Upadhyaya, Gouranga; Basak, Chandra; Das, Arup; Chakraborty, Chandrima; Ray, Sudipta

    2018-01-01

    Environmental stresses generate reactive oxygen species (ROS) which might be detrimental to the plants when produced in an uncontrolled way. However, the plants ameliorate such stresses by synthesizing antioxidants and enzymes responsible for the dismutation of ROS. Additionally, the dehydrins were also able to protect the inactivation of the enzyme lactate dehydrogenase against hydroxyl radicals (OH ⋅ ) generated during Fenton's reaction. SbDhn1 and SbDhn2 overexpressing transgenic tobacco plants were able to protect against oxidative damage. Transgenic tobacco lines showed better photosynthetic efficiency along with high chlorophyll content, soluble sugar and proline. However, the malonyl dialdehyde (MDA) content was significantly lower in transgenic lines. Experimental evidence demonstrates the protective effect of dehydrins on electron transport chain in isolated chloroplast upon methyl viologen (MV) treatment. The transgenic tobacco plants showed significantly lower superoxide radical generation () upon MV treatment. The accumulation of the H 2 O 2 was also lower in the transgenic plants. Furthermore, in the transgenic plants the expression of ROS scavenging enzymes was higher compared to non-transformed (NT) or vector transformed (VT) plants. Taken together these data, during oxidative stress dehydrins function by scavenging the () directly and also by rendering protection to the enzymes responsible for the dismutation of () thereby significantly reducing the amount of hydrogen peroxides formed. Increase in proline content along with other antioxidants might also play a significant role in stress amelioration. Dehydrins thus function co-operatively with other protective mechanisms under oxidative stress conditions rendering protection in stress environment.

  20. Provision of operational radiation protection services at nuclear power plants

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of this publication is to provide practical guidance on establishing and maintaining a radiation protection programme for a nuclear power plant that is consistent with the optimization process recommended in the Basic Safety Standards. This publication is written with a view to providing guidance to every person associated with the radiation protection programme for a nuclear power plant and develops the theme that radiation protection requires the commitment of all plant staff, including higher levels of executive management. 12 refs, 2 figs

  1. Design and implementation of an advanced protection system for the Shin-Kori 3 and 4 nuclear power plant

    International Nuclear Information System (INIS)

    Kim, Yonghak; Choi, Woongseock; Kwon, Jongsoo; Wilkosz, Stephen J.; Ridolfo, Charles F.; Yanosy, Paul L.

    2008-01-01

    The Nuclear Power Industry is currently embracing modern digital technology for upgrades to existing Instrumentation and Control (I and C) infrastructures as well as for incorporation into the next generation of new plants which will be coming 'on-line' during the next decade. This technology is being fully exploited for the next generation of advanced plant protection systems which will be initially deployed on the Shin-Kori 3 and 4 Nuclear Power Plant in the Republic of Korea. The system design for this plant protection system is being performed by the Korea Power Engineering Company (KOPEC) and builds upon the past generation of digital safety systems which were initially implemented at Ulchin 5 and 6. The advanced protection system is an evolution of this existing design and includes a number of improved operating attributes including: · Integration of Reactor Protection, Engineered Safety Features Actuation, and Qualified Indication and Alarm functions which were previously implemented by separate systems in the past. · Use of a 'soft control' interface which provides convenient accessibility to the safety systems from 'operator workstations' · Implementation of a Large Display Panel (LDP) which provides a consistent and constant representation of the overall plant state and of the plant safety status. The equipment for the advanced plant protection system is being provided by Westinghouse Electric Company (WEC) and utilizes the Westinghouse 'Common Q' Standardized qualified platform (where 'Q' denotes 'qualified'). The 'Common Q' platform is comprised of commercially dedicated Programmable Logic Controllers (PLC's), color-graphic Flat Panel Displays (FPD's) with integral touch screens, and high speed data communication links. It is a mature product that is in wide use for a number of safety-related applications. Among its key attributes are: · High overall system availability, which is achieved via use of a multiple channel configuration that is tolerant

  2. Radiation protection by medicinal plants

    International Nuclear Information System (INIS)

    Jagetia, Ganesh Chandra

    2002-01-01

    The development of effective non-toxic radioprotective agents is of considerable interest in the improvement of radiotherapy of cancer and protection against unplanned exposures. The synthetic drugs developed in post-world war II have had serious constrains in clinical applicable due to their toxicity at the optimal protective dose. Search for non-toxic protectors from natural sources have indicated that some of the commonly used medicinal plants and the poly herbal formulation could prove to be valuable sources of clinically useful radioprotectors as their ratio of effective dose to toxic dose is very high

  3. Programmed system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Jover, Pierre.

    1980-06-01

    The progress in the field of microprocessors and large scale integration circuits, have incited to introduce this new technologies into nuclear power plant protection system. The hardware and software design principles are briefly listed; then, a quad-redundant protection system for 1300 MWe PWR, developed in France is described [fr

  4. Developing a stochastic parameterization to incorporate plant trait variability into ecohydrologic modeling

    Science.gov (United States)

    Liu, S.; Ng, G. H. C.

    2017-12-01

    The global plant database has revealed that plant traits can vary more within a plant functional type (PFT) than among different PFTs, indicating that the current paradigm in ecohydrogical models of specifying fixed parameters based solely on plant functional type (PFT) could potentially bias simulations. Although some recent modeling studies have attempted to incorporate this observed plant trait variability, many failed to consider uncertainties due to sparse global observation, or they omitted spatial and/or temporal variability in the traits. Here we present a stochastic parameterization for prognostic vegetation simulations that are stochastic in time and space in order to represent plant trait plasticity - the process by which trait differences arise. We have developed the new PFT parameterization within the Community Land Model 4.5 (CLM 4.5) and tested the method for a desert shrubland watershed in the Mojave Desert, where fixed parameterizations cannot represent acclimation to desert conditions. Spatiotemporally correlated plant trait parameters were first generated based on TRY statistics and were then used to implement ensemble runs for the study area. The new PFT parameterization was then further conditioned on field measurements of soil moisture and remotely sensed observations of leaf-area-index to constrain uncertainties in the sparse global database. Our preliminary results show that incorporating data-conditioned, variable PFT parameterizations strongly affects simulated soil moisture and water fluxes, compared with default simulations. The results also provide new insights about correlations among plant trait parameters and between traits and environmental conditions in the desert shrubland watershed. Our proposed stochastic PFT parameterization method for ecohydrological models has great potential in advancing our understanding of how terrestrial ecosystems are predicted to adapt to variable environmental conditions.

  5. The Society for Radiological Protection: incorporated by Royal Charter. How it was achieved

    International Nuclear Information System (INIS)

    Hunt, John; Scott, John

    2008-01-01

    The Society for Radiological Protection (the Society) began to consider the potential for incorporation by Royal Charter, an important goal for many professional bodies in the UK, in the mid-1980s. Impetus grew during the 1990s; contributing to this in 1998 was the Society's new status as direct UK IRPA associate. In 2002, to emphasise that the Society is active over all sectors of radiation protection, sectorial committees were established, dealing with professional interests in the component sectors. Application for a Charter begins with a Memorandum to Her Majesty the Queen's Privy Council Office (PCO) with details of the Society, its achievements and why grant of a Charter would be in the public interest. The Society prepared a Memorandum and submitted it to the PCO in 2003. In 2004, the application was declined for several reasons, which were then considered. Contacts in Government Departments were briefed on the Society's activities. The Society and the Institute of Radiation Protection (IRP) had been considering amalgamation, and in 2005 the annual general meetings of the Society and IRP agreed to proposals for a merger. A new Memorandum was submitted to the PCO in 2005, and early in 2006 it was accepted. It was then necessary to draft a Charter and a Petition to HM the Queen in Council. One of the opportunities incorporated in the Charter is the provision to award the title 'Chartered Radiation Protection Professional' with the post-nominal letters 'CRadP' to suitable members. Draft documents were presented to the Society's 2007 annual general meeting, and passed through Society's governance procedures. Public consultation by the PCO took place during summer 2007. On 10 October 2007 an order granting a Charter of Incorporation was approved at the Privy Council held by the Queen. The Charter was presented to the Society on 11 December 2007. (author)

  6. Absorption of plant-incorporated nuclear fuel cycle elements from the gastro-intestinal tract

    International Nuclear Information System (INIS)

    Sullivan, M.F.; Garland, T.R.; Cataldo, D.A.; Schreckhise, R.G.

    1979-01-01

    Soybean plants (Glycine max cv Williams) grown hydroponically on solutions containing ammonium pertechnetate ( 95 Tcsup(m)O - 4 ) were fed to rats (omnivores) and guinea pigs (herbivores). Absorption of plant-incorporated technetium was compared with absorption of inorganic 95 Tcsup(m) from a gavaged solution or with absorption of 95 Tcsup(m) added to non-radioactive soybean tissues. In a second study absorption of plutonium from alfalfa (Medicago sativa cv Ladak) grown on soil amended with either 238 Pu nitrate or 238 Pu-DTPA was compared with absorption of gavaged 238 Pu solutions and 238 Pu mixed with non-radioactive alfalfa. Incorporation of 95 Tcsup(m) into soybean tissues resulted in decreased absorption by both animal species. In contrast, incorporation of 238 Pu in alfalfa resulted in an increased absorption when compared with controls that were administered inorganic 238 Pu. These results suggest that organic binding may alter, in either direction, absorption of nuclear fuel cycle elements. (author)

  7. Study on aging management of fire protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Fang Huasong; Du Yu; Li Jianwen; Shi Haining; Tu Fengsheng

    2010-01-01

    Fire prevention, fire fighting and fire automatic alarms are three aspects which be included in fire protection system in nuclear power plants. The fire protection system can protect personnel, equipment etc in the fire, so their performance will have a direct influence on the safe operation in nuclear power plants. The disabled accidents caused by aging have happened continuously with the extension of time in the fire protection system, which is the major security risk during the running time in nuclear power plants. In view of the importance of fire protection system and the severity of aging problems, the aging are highly valued by the plant operators and related organizations. Though the feedback of operating experience in nuclear power plant, the impact of the fire-fighting equipment aging on system performance and reliability be assessed, the aging sensitive equipment be selected to carry out the aging analysis and to guide the management and maintenance to guarantee the healthy operation in life time of fire protection system in nuclear power plant. (authors)

  8. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  9. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  10. Protective role of plants against harmful radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gautam, Shreesh Kumar; Kumar, Pawan; Singh, Abhishek; Kumar, Vikas; Bharti, Navaldey [Department of Applied Plant Science-Horticulture, Babasaheb Bhimrao Ambedkar University, Lucknow (India)

    2012-07-01

    The rapid technological advancement has increased human exposure to ionizing radiations enormously. Ionizing radiations produces deleterious effects in the living organisms. Widespread use of radiation in diagnosis therapy, industry, energy sector and inadvertent exposure during air and space travel, nuclear accidents and nuclear terror attacks requires safeguard against human exposures. Lead shielding and other physical measures can be used in such situations but with difficulty to manage; thus pharmacological intervention could be the most prudent strategy to protect humans against the harmful effect of ionizing radiations. These pharmacological agents are radioprotectives; The development of radioprotective agents has been the subject of intense research in view of their potential for use within a radiation environment. However, no ideal, safe synthetic radio protectors are available to date, so the search for alternative sources including plants has been ongoing. In Ayurveda, the traditional Indian system of medicine, several plants have been used to treat free radical-mediated ailments and, therefore, it is logical to expect that such plants may also render some protection against radiation damage. This all is due to antioxidant enzymes, nitroxides, and melatonin, antiemetic, anti-inflammatory. haemopoitic and immunostimulant compounds. Some of the plants which are found to be radioprotective are Centella asiatica, Ginkgo biloba, Hippophae rhamnoides, Ocimum sanctum, Podophyllurn hexandrum, Tinospora cordifolia, Emblica officinalis, Phyllanthus amarus, etc. So there is an urgent need to identify and characterize the many of the plants in relation to the radioprotection. Besides these medicinal plants there are also some fruits and vegetables which are having good response against harmful radiations such as Kiwifruit Actinidia deliciosa (Actinidaceae), Cape Gooseberry Physalis peruviana (Solanaceae). They protect against the radiation-induced damage by

  11. Protective role of plants against harmful radiation

    International Nuclear Information System (INIS)

    Gautam, Shreesh Kumar; Kumar, Pawan; Singh, Abhishek; Kumar, Vikas; Bharti, Navaldey

    2012-01-01

    The rapid technological advancement has increased human exposure to ionizing radiations enormously. Ionizing radiations produces deleterious effects in the living organisms. Widespread use of radiation in diagnosis therapy, industry, energy sector and inadvertent exposure during air and space travel, nuclear accidents and nuclear terror attacks requires safeguard against human exposures. Lead shielding and other physical measures can be used in such situations but with difficulty to manage; thus pharmacological intervention could be the most prudent strategy to protect humans against the harmful effect of ionizing radiations. These pharmacological agents are radioprotectives; The development of radioprotective agents has been the subject of intense research in view of their potential for use within a radiation environment. However, no ideal, safe synthetic radio protectors are available to date, so the search for alternative sources including plants has been ongoing. In Ayurveda, the traditional Indian system of medicine, several plants have been used to treat free radical-mediated ailments and, therefore, it is logical to expect that such plants may also render some protection against radiation damage. This all is due to antioxidant enzymes, nitroxides, and melatonin, antiemetic, anti-inflammatory. haemopoitic and immunostimulant compounds. Some of the plants which are found to be radioprotective are Centella asiatica, Ginkgo biloba, Hippophae rhamnoides, Ocimum sanctum, Podophyllurn hexandrum, Tinospora cordifolia, Emblica officinalis, Phyllanthus amarus, etc. So there is an urgent need to identify and characterize the many of the plants in relation to the radioprotection. Besides these medicinal plants there are also some fruits and vegetables which are having good response against harmful radiations such as Kiwifruit Actinidia deliciosa (Actinidaceae), Cape Gooseberry Physalis peruviana (Solanaceae). They protect against the radiation-induced damage by

  12. Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components

    International Nuclear Information System (INIS)

    Sinha, A.K.; Mitra, A.K.; Bhakta, U.C.; Sanyal, S.K.

    2000-01-01

    Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are also not feasible. Under such circumstances the applications of cathodic protection provides a long term solution the design of cathodic protection, for such applications differs from the commonly employed cathodic protection for cross-country pipelines and submerged structures due to other complexities in the plant region and maintenance of the applied system. The present paper intends to discuss the applications of cathodic protection with suitable anti-corrosive coatings for protection of various power plant components and the specific features of each type of application. (author)

  13. Wind Power Plant Control Optimisation with Incorporation of Wind Turbines and STATCOMs

    DEFF Research Database (Denmark)

    Petersen, Lennart; Kryezi, Fitim; Iov, Florin

    2015-01-01

    This paper addresses a detailed design and tuning of a wind power plant slope voltage control with reactive power contribution of wind turbines and STATCOMS. First, small-signal models of a single wind turbine and the whole wind power plant are developed, being appropriate for voltage control...... assessment. An exemplary wind power plant located in the United Kingdom and the corresponding grid code requirements are used as a base case. The final design and tuning process of the voltage controller results in a guidance, proposed for this particular control architecture. It provides qualitative...... outcomes regarding the impact of system delays, grid conditions and various operating conditions of the wind power plant, with and without incorporation of STATCOMS....

  14. Safety guide on fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    1976-01-01

    The purpose of the Safety Guide is to give specific design and operational guidance for protection from fire and explosion in nuclear power plants, based on the general guidance given in the relevant sections of the 'Safety Code of Practice - Design' and the 'Safety Code of Practice - Operation' of the International Atomic Energy Agency. The guide will confine itself to fire protection of safety systems and items important to safety, leaving the non-safety matters of fire protection in nuclear power plants to be decided upon the basis of the various available national and international practices and regulations. (HP) [de

  15. Problems of New Plant Variety Protection System in China and Countermeasures

    OpenAIRE

    GUAN, Yuwu

    2013-01-01

    Protection of new plant varieties has been long neglected in China, which has already restricted agricultural technological renovation, and influenced export of Chinese agricultural products. The current scientific and technological management system is not favorable for the output of right of new plant variety, and high cost of protecting new plant varieties directly results in agricultural researchers’ ignorance of right of new plant variety. Major causes were concluded as poor intellectu...

  16. A new career path in radiation protection training. Certified power plant shift supervisor. Radiation protection

    International Nuclear Information System (INIS)

    Terbeek, Christoph

    2011-01-01

    Apart from theoretical knowledge, effective day-to-day radiation protection operations also require a certain measure of practical experience. Therefore, the professional degree of 'Certified Radiation Worker', issued by the Chamber of Industry and Commerce (CIC) Aachen, Germany, established at an early stage. In order to provide experienced radiation protection specialists with an attractive career path, POWERTECH TRAINING CENTER e.V., in co-operation with VGB PowerTech. e.V., the Paul Scherrer Institute (Switzerland) and the Swiss Atomic Energy Agency (ENSI), has devised a new power plant shift supervisor training course specialising in radiation protection. The vocational training degree called 'Certified Power Plant Shift Supervisor - Radiation Protection' is awarded after successful completion of the advanced training examination conducted by the CIC in Essen, Germany. (orig.)

  17. Protecting chemical plants against terrorist attacks: a review

    NARCIS (Netherlands)

    Khakzad Rostami, N.; Reniers, G.L.L.M.E.

    2015-01-01

    Protection of hazardous establishments such as chemical plants intentional incidents has drawn attention from safety and security experts since 9/11 terrorist attacks in the U.S. Although major steps have been taken since, the recent intentional incidents in two chemical plants in France in June and

  18. Hazard rate for a two-channel protective system subject to a high demand rate

    International Nuclear Information System (INIS)

    Oliveira, L.F.; Youngblood, R.; Melo, P.F.F.

    1989-01-01

    A basic figure of merit associated with a protective system for an industrial plant is the number of accidents expected to occur in the plant within a given period of time, with the system installed. By definition, in a plant equipped with a protective system, an accident can only happen if an initiating event (a demand) occurs while the protective system is unavailable, that is, while it is in one of its possible failed states. This means that the hazard rate or accident frequency depends on the demand rate and on the unavailability of the protective systems. It has long been recognized that the demand rate influences the unavailability of the protective system, and practical expressions incorporating that effect have been developed for single-channel (Lees, 1982) and multi-channel (Kumamoto and Henley 1978) protective systems. The effect has also been incorporated into a Markovian treatment of a plant protection system (Papazoglou and Cho, 1985). In a previous paper (Oliveira and Netto, 1987) a Markovian approach was used to derive analytical expressions for the evaluation of the plant hazard rate for a single-channel protective system, properly accounting for the effects of the demand and the repair rates. In this paper the authors present an extension of that model to the case of a plant equipped with a two-channel protective system

  19. Protective Effect against Oxidative Stress in Medicinal Plant Extracts

    International Nuclear Information System (INIS)

    Kim, Jeong Hee; Lee, Eun Ju; Shin, Dong O; Hong, Sung Eun; Kim, Jin Kyu

    2000-01-01

    Protective effect of medicinal plant extracts against oxidative stress were screened in this study. Methanol extracts from 48 medicinal plants, which were reported to have antioxidative or anti-inflammatory effect were prepared and screened for their protective activity against chemically-induced and radiation-induced oxidative stress by using MTT assay. Thirty three samples showed protective activity against chemically-induced oxidative stress in various extent. Among those samples, extract of Glycyrrhiza uralensis revealed the strongest activity (25.9% at 100 μg/ml) with relatively lower cytotoxicity. Seven other samples showed higher than 20% protection at 100 μg/ml. These samples were tested for protection activity against radiation-induced oxidative stress. Methanol extract of Alpina officinarum showed the highest activity (17.8% at 20 μg/ml). Five fractions were prepared from the each 10 methanol extracts which showed high protective activity against oxidative stress. Among those fraction samples butanol fractions of Areca catechu var. dulcissima and Spirodela polyrrhiza showed the highest protective activities (78.8% and 77.2%, respectively, at 20 μg/ml)

  20. Course in fire protection training for nuclear power plant personnel

    International Nuclear Information System (INIS)

    Walker, K.L.; Bates, E.F.; Randall, J.D.

    1979-01-01

    Proposed Regulatory Guide 1.120, entitled ''Fire Protection Guidelines for Nuclear Power Plants,'' provides detailed requirements for the overall fire protection programs at nuclear power plant sites in the United States. An essential element in such a program in the training of plant fire brigade personnel is the use of proper firefighting techniques and equipment. The Texas A and M University Nuclear Science Center (NSC) in conjunction with the Fire Protection Training Division of the Texas Engineering Extension Service has developed a one-week course to meet this training need. The program emphasizes hands-on exercises. The course is designed for up to 18 students with all protective clothing provided. Fire instructors are certified by the State of Texas, and registered nuclear engineers and certified health physicists supervise the radiological safety exercises. The first course was conducted during the week of January 8--12, 1979

  1. Using Tradtional Ecological Knowledge to Protect Wetlands: the Swinomish Tribe's Wetland Cultural Assessment Project

    Science.gov (United States)

    Mitchell, T.

    2017-12-01

    "Traditional" wetland physical assessment modules do not adequately identify Tribal cultural values of wetlands and thus wetlands may not be adequately protected for cultural uses. This Swinomish Wetlands Cultural Assessment Project has developed a cultural resource scoring module that can be incorporated into wetland assessments to better inform wetland protections. Local native knowledge was gathered about the traditional uses of 99 native wetland plant species. A cultural scoring matrix was developed based on the presence of traditionally used plants in several use categories including: construction, ceremonial, subsistence, medicinal, common use, plant rarity, and place of value for each wetland. The combined score of the cultural and physcial modules provides an overall wetland score that relates to proscribed buffer protection widths. With this local native knowledge incorporated into wetland assessments, we are protecting and preserving Swinomish Reservation wetlands for both cultural uses and ecological functionality through the Tribe's wetland protection law.

  2. Radiological respiratory protection in Angra-1 Nuclear Power Plant

    International Nuclear Information System (INIS)

    Amaral, Marcos A. do

    1996-01-01

    The present paper has the purpose to describe the actual situation of the Radiological respiratory Protection in Angra I Nuclear Power Plant, the difficulties found and the goals to achieve, in order of the radiological protection excellence. (author)

  3. Fire protection guidelines for nuclear power plants

    International Nuclear Information System (INIS)

    1976-06-01

    Guidelines acceptable to the NRC staff for implementing in the development of a fire protection program for nuclear power plants. The purpose of the fire protection program is to ensure the capability to shut down the reactor and maintain it in a safe shutdown condition and to minimize radioactive releases to the environment in the event of a fire. If designs or methods different from the guidelines presented herein are used, they must provide fire protection comparable to that recommended in the guidelines. Suitable bases and justification should be provided for alternative approaches to establish acceptable implementaion of General Design Criterion 3

  4. Design aspects of radiation protection for nuclear power plants

    International Nuclear Information System (INIS)

    1985-01-01

    This Safety Guide deals with the provisions to be made in the design of thermal neutron reactor power plants to protect site personnel and the public from undue exposure to ionizing radiation during operational states and accident conditions. The effective radiation protection is a combination of good design, high quality construction and proper operation. The document gives guidance on how to satisfy the objectives contained in Subsection 2.2 and Section 9 of the Code of Practice on Design for Safety of Nuclear Power Plants

  5. Analysis of fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    Hosser, D.; Schneider, U.

    1982-01-01

    Regulations and test specifications for fire prevention in nuclear power plants are presented as well as the fire protection measures in a newly constructed nuclear power plant. Although the emphasis is placed differently, all rules are based on the following single measures: Fire prevention, fire detection, fire fighting, fire checking, attack, flight, and rescue, organisational measures. (orig./GL) [de

  6. Official control of plant protection products in Poland: detection of illegal products.

    Science.gov (United States)

    Miszczyk, Marek; Płonka, Marlena; Stobiecki, Tomasz; Kronenbach-Dylong, Dorota; Waleczek, Kazimierz; Weber, Roland

    2018-04-03

    Market presence of illegal and counterfeit pesticides is now a global problem. According to data published in 2012 by the European Crop Protection Association (ECPA), illegal products represent over 10% of the global market of plant protection products. Financial benefits are the main reason for the prevalence of this practice. Counterfeit and illegal pesticides may contain substances that may pose a threat to the environment, crops, animals, and humans, inconsistent with the label and registration dossier. In Poland, action against illegal and counterfeit plant protection products is undertaken by the Main Inspectorate of Plant Health and Seed Inspection (PIORiN), the police, the prosecution, and the pesticide producers. Results of chemical analyses carried out by the Institute of Plant Protection - National Research Institute Sośnicowice Branch, Pesticide Quality Testing Laboratory (PQTL IPP-NRI Sosnicowice Branch) indicate that a majority of illegal pesticides in Poland are detected in the group of herbicides. Products from parallel trade tend to have the most irregularities. This article describes the official quality control system of plant protection products in Poland and presents the analytical methods for testing pesticides suspected of adulteration and recent test results.

  7. Regulatory Guidance for Lightning Protection in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kisner, Roger A.; Wilgen, John B.; Ewing, Paul D.; Korsah, Kofi; Antonescu, Christina E.

    2006-01-01

    Oak Ridge National Laboratory (ORNL) was engaged by the U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research (RES) to develop the technical basis for regulatory guidance to address design and implementation practices for lightning protection systems in nuclear power plants (NPPs). Lightning protection is becoming increasingly important with the advent of digital and low-voltage analog systems in NPPs. These systems have the potential to be more vulnerable than older analog systems to the resulting power surges and electromagnetic interference (EMI) when lightning strikes facilities or power lines. This paper discusses the technical basis for guidance to licensees and applicants covered in Regulatory Guide (RG) 1.204, Guidelines for Lightning Protection of Nuclear Power Plants, issued August 2005. RG 1.204 describes guidance for practices that are acceptable to the NRC staff for protecting nuclear power structures and systems from direct lightning strikes and the resulting secondary effects.

  8. Radiation protection during operation of nuclear power plants

    International Nuclear Information System (INIS)

    1983-01-01

    This Guide describes a Radiation Protection Programme for nuclear power plants. It includes: (1) An outline of the basic principles as well as practical aspects of the programme; (2) A description of the responsibilities of the operating organization to establish an effective programme based upon these principles; (3) A description of the administrative and technical measures to establish and implement the programme. This Guide also deals with the operational aspects to be considered by the operating organization in reviewing design in order to facilitate implementation of the Radiation Protection Programme. This Guide covers the requirements for a Radiation Protection Programme for all operational states of the nuclear power plant. It also includes guidelines for handling planned special exposures and for coping with unplanned exposures and contamination of personnel, areas, and equipment. Additional information concerning emergency situations involving releases of radioactive materials is given in Safety Guides 50-SG-O6, ''Preparedness of the Operating Organization (Licensee) for Emergencies at Nuclear Power Plants'', and 50-SG-G6, ''Preparedness of Public Authorities for Emergencies at Nuclear Power Plants''. This Guide covers the principles of dose limitation to site personnel and to the public, but it does not include detailed instructions on the techniques used for the actual measurement and evaluation of the exposures. This Guide does not include detailed instructions on environmental surveys, but it does mention principal steps in environmental monitoring which may be required for confirmation of the acceptability of radioactive discharges

  9. Protection and environmental supervision activities at ROMAG PROD Plant

    International Nuclear Information System (INIS)

    Chilom, Rodica

    2002-01-01

    The protection and environmental supervision activity at ROMAG PROD heavy water plant is embodied in the very production process. The environmental supervision is done by: 1. the sensing system for H 2 S which monitors H 2 S and other gases 24 h/day on three zones of production storage and transport of H 2 S; 2. daily tightness checking of the installations working with H 2 S; 3. daily analytical checking of the air and water pollutants at seven air sampling checking points in dwelled zones, at the industrial area boundary and at purification stations and water waste discharge points. The water and air environmental components are protected through safe operation of the heavy water installations and of the flue gas installation. The water protection is ensured through optimal operation of the purification facilities, namely: the purification of the water resulting from the isotopic exchange; acid water neutralization station which process the waste water collected from the whole plant; neutralization reservoir for water resulting from ionic exchange; purification station of the sulfate waters resulting from the H 2 S fabrications installation; mud pool. The ROMAG PROD Plant operates according to the ISO 9001 and ISO 14001 standards and reports regularly its activity to the Environmental Protection and Water System Management Authority

  10. Plant nematodes in South Africa. 11. Checklist of plant nematodes of the protected areas of KwaZulu-Natal

    Directory of Open Access Journals (Sweden)

    Mariette Marais

    2013-03-01

    Full Text Available Nematodes are some of the most abundant soil organisms and are an essential part of soil ecology. These organisms are used as indicator organisms and can be linked to soil health. Biological collections contain vast amounts of data, with the National Collection of Nematodes housed at the Plant Protection Research Institute, Agricultural Research Council being no different. During the digitising of the collection a number of unpublished records of plant nematodes reported from protected areas in KwaZulu-Natal were found in the South African Plant-Parasitic Nematode Survey database. A total of 222 plant nematode species belonging to 39 genera were reported from the province, with only 94 of these species reported from the protected areas and 172 and 159 species reported from uncultivated (outside the protected areas and cultivated areas, respectively. Only nine species, Criconema silvum, Criconema talanum, Helicotylenchus marethae, Ogma dracomontanum, Ogma louisi, Ogma ueckermanni, Paralongidorus deborae, Trichodorus rinae and Xiphinemella marindae were described from protected areas, whilst O. dracomontanum, P. deborae and T. rinae were subsequently also reported from other provinces. Conservation implications: A higher degree of diversity of nematodes was observed in the unprotected areas of the province. The observation suggests that nematode fauna, and by implication also other invertebrates, are not adequately protected.

  11. Plant nematodes in South Africa. 11. Checklist of plant nematodes of the protected areas of KwaZulu-Natal

    Directory of Open Access Journals (Sweden)

    Mariette Marais

    2013-02-01

    Full Text Available Nematodes are some of the most abundant soil organisms and are an essential part of soil ecology. These organisms are used as indicator organisms and can be linked to soil health. Biological collections contain vast amounts of data, with the National Collection of Nematodes housed at the Plant Protection Research Institute, Agricultural Research Council being no different. During the digitising of the collection a number of unpublished records of plant nematodes reported from protected areas in KwaZulu-Natal were found in the South African Plant-Parasitic Nematode Survey database. A total of 222 plant nematode species belonging to 39 genera were reported from the province, with only 94 of these species reported from the protected areas and 172 and 159 species reported from uncultivated (outside the protected areas and cultivated areas, respectively. Only nine species, Criconema silvum, Criconema talanum, Helicotylenchus marethae, Ogma dracomontanum, Ogma louisi, Ogma ueckermanni, Paralongidorus deborae, Trichodorus rinae and Xiphinemella marindae were described from protected areas, whilst O. dracomontanum, P. deborae and T. rinae were subsequently also reported from other provinces. Conservation implications: A higher degree of diversity of nematodes was observed in the unprotected areas of the province. The observation suggests that nematode fauna, and by implication also other invertebrates, are not adequately protected.

  12. Training of fire protection personnel in nuclear power plants

    International Nuclear Information System (INIS)

    Blaser, W.

    1980-01-01

    Training of fire protection personnel in nuclear power plants is divided up in three categories: training of fire protection commissioners which is mostly carried out externally; training of fire fighting personnel in the form of basic and repeated training usually by the fire protection commissioner; training of other employers with regard to behaviour in case of fire and during work involving a fire hazard. (orig.) [de

  13. 7 CFR 371.3 - Plant protection and quarantine.

    Science.gov (United States)

    2010-01-01

    ...) Regulating the field release into the environment, interstate movement, and importation of genetically modified organisms. (7) Serving as a member of the North American Plant Protection Organization (NAPPO...

  14. Support of protective work of human error in a nuclear power plant

    International Nuclear Information System (INIS)

    Yoshizawa, Yuriko

    1999-01-01

    The nuclear power plant human factor group of the Tokyo Electric Power Co., Ltd. supports various protective work of human error conducted at the nuclear power plant. Its main researching theme are studies on human factor on operation of a nuclear power plant, and on recovery and common basic study on human factor. In addition, on a base of the obtained informations, assistance to protective work of human error conducted at the nuclear power plant as well as development for its actual use was also promoted. Especially, for actions sharing some dangerous informations, various assistances such as a proposal on actual example analytical method to effectively understand a dangerous information not facially but faithfully, construction of a data base to conveniently share such dangerous information, and practice on non-accident business survey for a hint of effective promotion of the protection work, were promoted. Here were introduced on assistance and investigation for effective sharing of the dangerous informations for various actions on protection of human error mainly conducted in nuclear power plant. (G.K.)

  15. Radiological protection and nuclear power plants

    International Nuclear Information System (INIS)

    Delpla, M.

    Dosimetric results obtained inside and outside nuclear power plants are examined with a review to proposing revision of the radiological protection standards. Dose limits are considered with regard to leukemia and genetic effects. Other topics discussed are: observed collective damage and mean risk; lethal exposure; healing and sign change of additional risk; and genetic effects of radiation on mice

  16. 78 FR 55765 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Science.gov (United States)

    2013-09-11

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Draft..., ``Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN-FIRE).'' In... caused by impaired fire protection features at nuclear power plants. The report documents the history of...

  17. Plant protection in post-Soviet Kazakhstan: the loss of an ecological perspective

    NARCIS (Netherlands)

    Toleubayev, K.

    2009-01-01

    This thesis examines why and how plant protection issues are embedded in political, economic and social contexts. It analyses the domain of plant protection in Kazakhstan under two different socio-economic and political formations, namely the Soviet period before 1991 and the post-Soviet period

  18. Corrosion protection pays off for coal-fired power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, T.

    2006-11-15

    Zinc has long been used to hot-dip galvanise steel to deliver protection in harsh environments. Powder River Basin or eastern coal-fired plants benefit from using galvanized steel for conveyors, vibratory feeders, coal hoppers, chutes, etc. because maintenance costs are essentially eliminated. When life cycle costs for this process are compared to an alternative three-coal paint system for corrosion protection, the latter costs 5-10 times more than hot-dip galvanizing. An AEP Power Plant in San Juan, Puerto Rico and the McDuffie Coal Terminal in Mobile, AL, USA have both used hot-dip galvanized steel. 1 fig., 1 tab.

  19. 78 FR 45573 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Science.gov (United States)

    2013-07-29

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Notice of... Nuclear Power Plant Fire Protection (CARMEN-FIRE), Draft Report for Comment.'' DATES: Comments on this... caused by impaired fire protection features at nuclear power plants. The report documents the history of...

  20. Biochemical analysis of plant protection afforded by a nonpathogenic endophytic mutant of Colletotrichum magna

    Energy Technology Data Exchange (ETDEWEB)

    Redman, R.S.; Rodriguez, R.J. (Geological Survey, Seattle, WA (United States) Univ. of Washington, Seattle, WA (United States). Dept. of Botany); Clifton, D.R.; Morrel, J.; Brown, G. (Geological Survey, Seattle, WA (United States)); Freeman, S. (Volcani Center, Bet Dagan (Israel). Dept. of Plant Pathology)

    1999-02-01

    A nonpathogenic mutant of Colletotrichum magna (path-1) was previously shown to protect watermelon (Citrullus lanatus) and cucumber (Cucumis sativus) seedlings from anthracnose disease elicited by wild-type C. magna. Disease protection was observed in stems of path-1-colonized cucurbits but not in cotyledons, indicating that path-1 conferred tissue-specific and/or localized protection. Plant biochemical indicators of a localized and systemic (peroxidase, phenylalanine ammonia-lyase, lignin, and salicylic acid) plant-defense response were investigated in anthracnose-resistant and-susceptible cultivars of cucurbit seedlings exposed to four treatments: (1) water (control), (2) path-1 conidia, (3) wild-type conidia, and (4) challenge conditions (inoculation into path-1 conidia for 48 h and then exposure to wild-type conidia). Collectively, these analyses indicated that disease protection in path-1-colonized plants was correlated with the ability of these plants to mount a defense response more rapidly and to equal or greater levels than plants exposed to wild-type C. magna alone. Watermelon plants colonized with path-1 were also protected against disease caused by Colletotrichum orbiculare and Fusarium oxysporum. A model based on the kinetics of plant-defense activation is presented to explain the mechanism of path-1-conferred disease protection.

  1. 45 CFR 670.25 - Designation of specially protected species of native mammals, birds, and plants.

    Science.gov (United States)

    2010-10-01

    ... native mammals, birds, and plants. 670.25 Section 670.25 Public Welfare Regulations Relating to Public... Protected Species of Mammals, Birds, and Plants § 670.25 Designation of specially protected species of native mammals, birds, and plants. The following species has been designated as Specially Protected...

  2. Laws and ordinances on electric arc protection. Electric arc protection of electric plants; Gesetze und Verordnungen zur Stoerlichtbogensicherheit. Stoerlichtbogensicherheit von elektrischen Betriebsstaetten

    Energy Technology Data Exchange (ETDEWEB)

    Bernards, Stefan; Buenger, Stefan; Grote, Martin [Fritz Driescher KG - Spezialfabrik fuer Elektrizitaetswerksbedarf GmbH und Co., Wegberg (Germany); Boettcher, Lutz-Michael [Ingenieurbuero Boettcher-Consult, Schulzendorf (Germany); Weck, Karl-Heinz [Forschungsgemeinschaft fuer Elektrische Anlagen und Stromwirtschaft (FGH e.V.), Mannheim (Germany)

    2011-02-28

    With the publication of the new standards IEC 62271-200/VDE 0671 part 200-2003: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV, and IEC 62271-202/VDE 0671 part 202-2007: High voltage/low voltage prefabricated substations and their revision, the fundamentals of arc protection qualification of plants and stations were redefined with a view to personnel protection. In the case of new transformer stations, the application of these standards is state of the art. The publications and the application of the new standards for staff protection, plant protection and object protection via electric arc qualification has raised questions concerning the safety of older plants and stations, modernization, reconstruction, enhancement, maintenance, and the re-use of used stations and plants.

  3. Carbon steel protection in G.S. [Girldler sulphide] plants: Pt. 7

    International Nuclear Information System (INIS)

    Lires, Osvaldo; Delfino, Cristina; Rojo, Enrique.

    1989-01-01

    In order to protect carbon steel towers and piping of a GS experimental heavy water plant against corrosion produced by the action of aqueous solutions of hydrogen sulphide, a method, elsewhere published, was developed. Carbon steel exposed to saturated aqueous solutions of hydrogen sulphide forms iron sulphide scales. In oxygen free solutions, evolution of corrosion follows the sequence mackinawite → cubic ferrous sulphide → troilite → pyrrotite → pyrite. Scales formed by pyrrotite and pyrite are the most protective layers (these are obtained at 130 deg C, 2 MPa for a period of 14 days). During a plant shutdown procedures, the carbon steel protected with those scales is exposed to water and highly humid air; under such conditions oxidation is unavoidable. Later, treatment in plant conditions does not regenerate scales because the composition of regenerated scales involves more soluble iron sulphides such as mackinawite and troilite. Therefore, it is not recommendable to expose the protective scales to atmospherical conditions. (Author)

  4. Modernization of the WWER 440/230 nuclear power plant environmental protection system

    Energy Technology Data Exchange (ETDEWEB)

    Mikheev, N.V.; Kamenskaya, A.N.; Kulyukhin, S.A.; Novichenko, V.L.; Rumer, I.A. [Russian Academy of Sciences, Institute of Physical Chemistry, Moscow (Russian Federation); Antonov, B.V.; Kornienko, A.G.; Meshkov, V.M.; Rogov, M.F. [Rosenergoatom Concern, Moscow (Russian Federation)

    2001-07-01

    The papers reports a new approach to the problem of increasing environmental protection during severe accidents at WWER 440/230 nuclear power plants. The environmental protection system that we propose has three, not two protection levels, and can be introduced with minor modernization of the equipment available at WWER 440/230 nuclear power plants: 1. a jet-vortex condenser; 2. the sprinkler system; 3. a sorption module. The proposed modernization not only makes it possible to avoid emergency discharge of radioactive air and steam mix into the environment under any accident scenario, but also would substantially contribute to the safety of WWER 440/230 nuclear power plants. (author)

  5. Lightning protection of oil and gas industrial plants

    Energy Technology Data Exchange (ETDEWEB)

    Bouquegneau, Christian [Polytechnical University of Mons (Belgium)

    2007-07-01

    The paper brings some cases and presents the general principles, what the IEC 62305 international standard says, the warning and avoidance and the conclusion about lightning protection of oil and gas industrial plants.

  6. Incorporation of natural radionuclides and rare earth element into a salt tolerant plant

    International Nuclear Information System (INIS)

    Summerton, A.P.

    1992-01-01

    A highly salt tolerant shrub, samphire (Halosarcia halocnemoides), found growing in the solid alkaline residues in an evaporation pond at a former uranium and monazite treatment plant, has been analysed for natural radionuclides and rare earths. The data obtained have been copared with that for plants from the local natural environment. Vegetation-to-soil concentration ratios have been determined. The radionuclide concentration ratios for samples from the contaminated site are similar to those from the natural environment. Significant differences have been noted in the case of the rare earth elements with an apparent preferential incorporation of the light rare earth elements into the plant growing in the chemical residues. (author) 10 refs.; 1 fig.; 2 tabs

  7. Preferential campesterol incorporation into various tissues in apolipoprotein E*3-Leiden mice consuming plant sterols or stanols

    NARCIS (Netherlands)

    Plat, J.; Jong, A.de; Volger, O.L.; Princen, H.M.G.; Mensink, R.P.

    2008-01-01

    Intestinal absorption of plant sterols and stanols is much lower as compared with that of cholesterol; and therefore, serum concentrations are low. Circulating plant sterols and stanols are incorporated into tissues. However, hardly any data are available about tissue distributions of individual

  8. Plant protection means used in organic farming throughout the European Union.

    Science.gov (United States)

    Matyjaszczyk, Ewa

    2018-03-01

    Following the obligatory implementation of integrated pest management in the European Union (EU), the plant protection means suitable for application in organic agriculture attracted the attention of quite a wide group of potential users. In spite of the common rules of organic production, as well as the uniform principles of placing plant protection products on the market, the availability of products that can be legally used in organic crop protection differs significantly among the Member States. There is a uniform list of 10 basic substances that can be used in the protection of organic crops throughout the entire EU. Twelve Member States have official registers of plant protection products for use in organic agriculture, and the total number of qualified products per country varies from 11 in Lithuania to 576 in Italy. Some products that improve plant vigour or resistance and may be of use in protection of organic crops are placed on the market as biostimulants. They fall under the law that governs fertilisers and the systems of their registration vary widely among the Member States. In addition, there exist a number of products that have been legally introduced onto the markets of some Member States without registration as a consequence of a loophole in the law. The use of unregistered products in organic agriculture raises some doubts, but currently it seems that there is no legal basis on which to explicitly prohibit the practice. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Summary report of workshop on sabotage protection in nuclear power plant design

    International Nuclear Information System (INIS)

    1977-02-01

    During the Summer of 1976, Sandia Laboratories hosted a workshop on Sabotage Protection in Nuclear Power Plant Design in which 11 consultants from the nuclear power industry participated. Each consultant is highly qualified and experienced in nuclear power plant design. The objective of the workshop was to identify practicable design measures which could be employed in future nuclear power plants to provide increased protection against sabotage. The report summarizes the conclusions and recommendations of the workshop

  10. Relay Protection Coordination for Photovoltaic Power Plant Connected on Distribution Network

    OpenAIRE

    Nikolovski, Srete; Papuga, Vanja; Knežević, Goran

    2014-01-01

    This paper presents a procedure and computation of relay protection coordination for a PV power plant connected to the distribution network. In recent years, the growing concern for environment preservation has caused expansion of photovoltaic PV power plants in distribution networks. Numerical computer simulation is an indispensable tool for studying photovoltaic (PV) systems protection coordination. In this paper, EasyPower computer program is used with the module Power Protector. Time-curr...

  11. Fire protection in nuclear power plants

    International Nuclear Information System (INIS)

    Wright, H.A.

    1981-01-01

    This lecture describes briefly the chronological order of events which may arise for a very serious emergency situation in a nuclear power plant for which preparations should be made even though the situation has an extremely low probability of happening. The planning and preparedness required are expected to cope with a whole spectrum of emergency situations, from minor accidents to serious plant failures which also lead to releases of significant quantities of radioactive material beyond the site boundary. Fire protection aspects will be briefly covered, and some guidance will be provided on exercises to ensure the plans are feasible and the appropriate personnel and facilities are in a satisfactory state of preparedness. (orig./RW)

  12. Radiation protection of population under normal operation conditions of nuclear power plants

    International Nuclear Information System (INIS)

    Kunz, Eh.; Shvets, I.

    1976-01-01

    Evolution of shielding is defined in short; approaches suggested for applying in radiation protection or being used are evaluated and classified. Modern views analysis of a risk of biological irradiation consequences in public approaches to health protection in connection with the technical progress side by side with provision of separate persons protection requires attentin to the nuclear power plants protection optimization. Protection optimization suggests the analysis of separate components of technology and protection systems, used materials and constructive solutions, maintenance rules and operating load with respect to environmental discharge of radioactive products. It is expedient to carry out similtaneously the similar analysis with respect to the nuclear power plant personnel irradiation, as separate measures can affect both personnel and population irradiation [ru

  13. Protective clothing use at the Savannah River Plant Nuclear Facility

    International Nuclear Information System (INIS)

    Cabbil, C.C.

    1987-01-01

    The mission of the Savannah River Plant in producing nuclear materials does pose some unique protective clothing and equipment requirements not usually seen in the general industry. In addition to protection from the chemicals and physical agents encountered, radioactive hazards must also be managed. This paper describes the protective clothing and respiratory protection used at SRP, and focuses particularly on the development of a new plastic suit. 5 refs., 7 figs., 3 tabs

  14. Wind Power Plant Grounding, Overvoltage Protection, and Insulation Coordination

    Energy Technology Data Exchange (ETDEWEB)

    Camm, E H [IEEE PES Wind Plant Collector System Design Working Group; Behnke, M. R. [IEEE PES Wind Plant Collector System Design Working Group; Bolado, O. [IEEE PES Wind Plant Collector System Design Working Group; Bollen, M. [IEEE PES Wind Plant Collector System Design Working Group; Bradt, M. [IEEE PES Wind Plant Collector System Design Working Group; Brooks, C. [IEEE PES Wind Plant Collector System Design Working Group; Dilling, W. [IEEE PES Wind Plant Collector System Design Working Group; Edds, M. [IEEE PES Wind Plant Collector System Design Working Group; Hejdak, W. J. [IEEE PES Wind Plant Collector System Design Working Group; Houseman, D. [IEEE PES Wind Plant Collector System Design Working Group; Klein, S. [IEEE PES Wind Plant Collector System Design Working Group; Li, Fangxing [ORNL; Li, J. [IEEE PES Wind Plant Collector System Design Working Group; Maibach, P. [IEEE PES Wind Plant Collector System Design Working Group; Nicolai, T. [IEEE PES Wind Plant Collector System Design Working Group; Pasupulati, S. V. [IEEE PES Wind Plant Collector System Design Working Group; Patino, J. [IEEE PES Wind Plant Collector System Design Working Group; Samaan, N. [IEEE PES Wind Plant Collector System Design Working Group; Saylors, S. [IEEE PES Wind Plant Collector System Design Working Group; Siebert, T. [IEEE PES Wind Plant Collector System Design Working Group; Smith, Travis M [ORNL; Starke, Michael R [ORNL; Walling, R. [IEEE PES Wind Plant Collector System Design Working Group

    2009-01-01

    Proper insulation coordination is critical to achieving expected life from wind plant equipment. The collector systems of large wind plants require the application of surge arresters to protect the equipment insulation from transient overvoltages. The application of surge arresters is constrained by maximum operating and temporary overvoltage levels. This paper provides a tutorial description of the process of selecting and applying surge arresters to wind plant medium voltage collector systems, with emphasis on the peculiar properties of this application.

  15. Plant foods and plant-based diets: protective against childhood obesity?

    Science.gov (United States)

    Newby, P K

    2009-05-01

    The objective of this article is to review the epidemiologic literature examining the role of plant foods and plant-based diets in the prevention of childhood obesity. Available data suggest a protective effect of ready-to-eat cereal on risk of obesity, although prospective studies are still needed. Studies on fruit and vegetables; grains other than cereal; high-protein foods, including beans, legumes, and soy; fiber; and plant-based dietary patterns are inconsistent or generally null. The evidence base is limited, and most studies are fraught with methodologic limitations, including cross-sectional design, inadequate adjustment for potential confounders, and lack of consideration of reporting errors, stage of growth, and genetic influences. Well-designed prospective studies are needed. The lack of evidence showing an association between plant-based diets and childhood obesity does not mean that such diets should not be encouraged. Plant foods are highlighted in the Dietary Guidelines for Americans, and children do not meet the current recommendations for most plant foods. Although the advice to consume a plant-based, low-energy-dense diet is sound, ethical questions arise concerning the relatively high price of these diets in the United States and the way in which such diets are perceived in other parts of the world. Reducing the burden of childhood obesity, eliminating health disparities, and preventing the further spread of the disease around the globe will require not only policy interventions to ensure that plant foods are affordable and accessible to children of all income levels but also awareness of sociocultural norms that affect consumption.

  16. Physical protection of nuclear power plants-technical and legal aspects

    International Nuclear Information System (INIS)

    Castro Martins, O.J. de.

    1978-04-01

    The nuclear power plants are defined according to the definitions included in the Brazilian legislation and international conventions and their physical protection is analysed. Besides, the differences and the relations among nuclear security, safeguards and physical protection are established. (A.L.) [pt

  17. Nuclear power plant fire protection: philosophy and analysis

    International Nuclear Information System (INIS)

    Berry, D.L.

    1980-05-01

    This report combines a fire severity analysis technique with a fault tree methodology for assessing the importance to nuclear power plant safety of certain combinations of components and systems. Characteristics unique to fire, such as propagation induced by the failure of barriers, have been incorporated into the methodology. By applying the resulting fire analysis technique to actual conditions found in a representative nuclear power plant, it is found that some safety and nonsafety areas are both highly vulnerable to fire spread and impotant to overall safety, while other areas prove to be of marginal importance. Suggestions are made for further experimental and analytical work to supplement the fire analysis method

  18. 40 CFR 174.526 - Hygromycin B phosphotransferase (APH4) marker protein in all plants; exemption from the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Hygromycin B phosphotransferase (APH4) marker protein in all plants; exemption from the requirement of a tolerance. 174.526 Section 174.526 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PROCEDURES AND REQUIREMENTS FOR PLANT-INCORPORATED...

  19. 2-Fluoro-L-Fucose Is a Metabolically Incorporated Inhibitor of Plant Cell Wall Polysaccharide Fucosylation

    Science.gov (United States)

    Wallace, Ian S.

    2015-01-01

    The monosaccharide L-fucose (L-Fuc) is a common component of plant cell wall polysaccharides and other plant glycans, including the hemicellulose xyloglucan, pectic rhamnogalacturonan-I (RG-I) and rhamnogalacturonan-II (RG-II), arabinogalactan proteins, and N-linked glycans. Mutations compromising the biosynthesis of many plant cell wall polysaccharides are lethal, and as a result, small molecule inhibitors of plant cell wall polysaccharide biosynthesis have been developed because these molecules can be applied at defined concentrations and developmental stages. In this study, we characterize novel small molecule inhibitors of plant fucosylation. 2-fluoro-L-fucose (2F-Fuc) analogs caused severe growth phenotypes when applied to Arabidopsis seedlings, including reduced root growth and altered root morphology. These phenotypic defects were dependent upon the L-Fuc salvage pathway enzyme L-Fucose Kinase/ GDP-L-Fucose Pyrophosphorylase (FKGP), suggesting that 2F-Fuc is metabolically converted to the sugar nucleotide GDP-2F-Fuc, which serves as the active inhibitory molecule. The L-Fuc content of cell wall matrix polysaccharides was reduced in plants treated with 2F-Fuc, suggesting that this molecule inhibits the incorporation of L-Fuc into these polysaccharides. Additionally, phenotypic defects induced by 2F-Fuc treatment could be partially relieved by the exogenous application of boric acid, suggesting that 2F-Fuc inhibits RG-II biosynthesis. Overall, the results presented here suggest that 2F-Fuc is a metabolically incorporated inhibitor of plant cellular fucosylation events, and potentially suggest that other 2-fluorinated monosaccharides could serve as useful chemical probes for the inhibition of cell wall polysaccharide biosynthesis. PMID:26414071

  20. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  1. Bio-based resistance inducers for sustainable plant protection against pathogens

    Czech Academy of Sciences Publication Activity Database

    Burketová, Lenka; Trdá, Lucie; Ott, P.G.; Valentová, O.

    2015-01-01

    Roč. 33, č. 6 (2015), s. 994-1004 ISSN 0734-9750 R&D Projects: GA MŠk(CZ) LD14056 Institutional support: RVO:61389030 Keywords : Induced resistance * Elicitor * Chitosan Subject RIV: GF - Plant Pathology, Vermin, Weed, Plant Protection Impact factor: 9.848, year: 2015

  2. PWR plant operator training used full scope simulator incorporated MAAP model

    International Nuclear Information System (INIS)

    Matsumoto, Y.; Tabuchi, T.; Yamashita, T.; Komatsu, Y.; Tsubouchi, K.; Banka, T.; Mochizuki, T.; Nishimura, K.; Iizuka, H.

    2015-01-01

    NTC makes an effort with the understanding of plant behavior of core damage accident as part of our advanced training. For the Fukushima Daiichi Nuclear Power Station accident, we introduced the MAAP model into PWR operator training full scope simulator and also made the Severe Accident Visual Display unit. From 2014, we will introduce new training program for a core damage accident with PWR operator training full scope simulator incorporated the MAAP model and the Severe Accident Visual Display unit. (author)

  3. Oak Ridge Y-12 Plant groundwater protection program management plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    The Oak Ridge Y- 1 2 Plant (Y-12 Plant) is owned by the United States Department of Energy (DOE) and managed by Lockheed Martin Energy Systems, Inc. (Energy Systems) under contract No. DE-AC05-84OR21400. The Y-12 Plant Groundwater Protection Program (GWPP), which was initiated in 1975, provides for the protection of groundwater resources consistent with Federal, State, and local regulations, and in accordance with DOE orders and Energy Systems policies and procedures. The Y-12 Plant is located in Anderson County, Tennessee, and is within the corporate limits of the City of Oak Ridge. The Y-12 Plant is one of three major DOE complexes that comprise the 37,000-acre Oak Ridge Reservation (ORR) located in Anderson and Roane counties. The Y-12 Plant is located in Bear Creek Valley at an elevation of about 950 feet (ft) above sea level. Bear Creek Valley is bounded on the northwest and southeast, and is isolated from populated areas of Oak Ridge, by parallel ridges that rise about 300 ft above the valley floor. The Y-12 Plant and its fenced buffer area are about 0.6 mile wide by 3.2 miles long and cover approximately 4,900 acres. The main industrialized section encompasses approximately 800 acres.

  4. Oak Ridge Y-12 Plant groundwater protection program management plan

    International Nuclear Information System (INIS)

    1996-06-01

    The Oak Ridge Y- 1 2 Plant (Y-12 Plant) is owned by the United States Department of Energy (DOE) and managed by Lockheed Martin Energy Systems, Inc. (Energy Systems) under contract No. DE-AC05-84OR21400. The Y-12 Plant Groundwater Protection Program (GWPP), which was initiated in 1975, provides for the protection of groundwater resources consistent with Federal, State, and local regulations, and in accordance with DOE orders and Energy Systems policies and procedures. The Y-12 Plant is located in Anderson County, Tennessee, and is within the corporate limits of the City of Oak Ridge. The Y-12 Plant is one of three major DOE complexes that comprise the 37,000-acre Oak Ridge Reservation (ORR) located in Anderson and Roane counties. The Y-12 Plant is located in Bear Creek Valley at an elevation of about 950 feet (ft) above sea level. Bear Creek Valley is bounded on the northwest and southeast, and is isolated from populated areas of Oak Ridge, by parallel ridges that rise about 300 ft above the valley floor. The Y-12 Plant and its fenced buffer area are about 0.6 mile wide by 3.2 miles long and cover approximately 4,900 acres. The main industrialized section encompasses approximately 800 acres

  5. Ageing study of protection automation components of Olkiluoto nuclear power plant

    International Nuclear Information System (INIS)

    Simola, K.; Haenninen, S.

    1993-07-01

    A study on ageing of reactor protection system of the Olkiluoto nuclear power plant is described. The objective of the study was to present an ageing analysis approach and apply in to the automation chains of reactor protection system of the Olkiluoto nuclear power plant. The study includes the measuring instrumentation, the protection logics, and the control electronics of some pumps and valves. The analysis is based on the information collected on the structure of the system, environmental conditions and maintenance practices of components, and operating experience. Based on this information, the possible ageing effects of equipment and their safety significance are evaluated. (orig.). (15 refs., 16 figs., 12 tabs.)

  6. Measures of radiation protection in the operation of nuclear power plants in the German Democratic Republic

    International Nuclear Information System (INIS)

    Richter, D.; Schreiter, W.

    1975-11-01

    A survey is given on the provisions concerning (a) radiation protection at nuclear power plants in the GDR including the instructions applying within the plant, (b) the organization of radiation protection services, and (c) the measures of radiation protection surveillance inside and outside the plant during operation. (author)

  7. 5-Point programme for sustainable plant protection.

    Science.gov (United States)

    Frische, Tobias; Egerer, Sina; Matezki, Steffen; Pickl, Christina; Wogram, Jörn

    2018-01-01

    This position paper intends to stimulate a profound rethinking of contemporary agricultural practice. We criticise the current intensity of chemical plant protection in Germany as ecologically unsustainable and thus threatening the achievement of key targets of environmental protection and nature conservation policies. In the first part of the paper, we provide background information on the use of plant protection products (PPP) in German agriculture, the role of agricultural policy, European pesticide legislation, the principles of and framework for environmental risk assessment and risk management of PPP, as well as environmental effects of PPP. The second part is presented against the backdrop of the European "Sustainable Use Directive" (2009/128/EC). This directive requires that "Member States shall adopt National Action Plans to set up their quantitative objectives, targets, measures, and timetables to reduce risks and impacts of pesticide use on human health and the environment and to encourage the development and introduction of integrated pest management and of alternative approaches or techniques to reduce dependency on the use of pesticides." Reflecting on the corresponding debate in Germany, we suggest the following five key principles for a sustainable use of PPP and provide recommendations for their implementation: (1) minimising use; (2) identifying, quantifying, and communicating risks; (3) optimising risk management; (4) compensating for unavoidable effects; (5) internalising external costs.

  8. LMFBR plant design features for sodium spill and fire protection

    International Nuclear Information System (INIS)

    Palm, R.E.

    1982-01-01

    Design features have been developed for an LMFBR plant to protect the concrete structures from potential liquid spills and fires and prevent sodium-concrete reactions. The inclusion of these features in the plant design reduces the severity of design basis accident conditions imposed on containment and other critical plant structures. Steel liners are provided in cells containing radioactive sodium systems, and catch pans are located in non-radioactive sodium system cells. The design requirements and descriptions of each of these protective features are presented. The loading conditions, analytical approach and numerical results are also included. Design of concrete cell structures that are subject to high temperature effects from sodium spills is discussed. The structural design considers the influence of high temperature on design properties of concrete and carbon steel materials based on results of a comprehensive test program. The development of these design features and high temperature design considerations for the Clinch River Breeder Reactor Plant (CRBRP) are presented in this paper

  9. War protected underground siting of nuclear power plants -a summary

    International Nuclear Information System (INIS)

    1974-06-01

    In connection with studies concerning the need of war protected nuclear power production the technical and economical conditions with war protection of nuclear power plants have been studied within CDL. Comprehensively one have shown that no technical construction obstacles for siting a nuclear power plant underground exist that the additional costs for underground siting with price level mid 1973 are some 175-250 MSwCr (In today's price level 250 MSwCr will probably correspond to some 300 MSwCr per unit) and that the construction time is some one year longer than for an above ground plant. A study ought to examine more closely the consequences of underground siting from a radiological point of view and what demands on that occasion ought to be put on the technical design. (author)

  10. Development and implementation of a comprehensive groundwater protection program at the Savannah River Plant

    International Nuclear Information System (INIS)

    Gordon, D.E.

    1984-01-01

    The major goals of the groundwater protection program are to evaluate the impact on groundwater quality as a result of Savannah River Plant operations, to take corrective measures as required to restore or protect groundwater quality, and to ensure that future operations do not adversely affect the quality or availability of the groundwater resources at the site. The specific elements of this program include (1) continuation of an extensive groundwater monitoring program, (2) assessment of waste disposal sites for impacts on groundwater quality, (3) implementation of mitigative actions, as required, to restore or protect groundwater quality, (4) incorporation of groundwater protection concepts in the design of new production and waste management facilities, and (5) review of site utilization of groundwater resources to ensure compatibility with regional needs. The major focal points of the groundwater protection program are the assessment of waste disposal sites for impacts on groundwater quality and the implementation of remedial action projects. Many locations at SRP have been used as waste disposal sites for a variety of liquid and solid wastes. Field investigations are ongoing to determine the nature and extent of any contamination in the sediments and groundwater at these waste sites on a priority basis. Remedial action has been initiated. Certain aspects of the groundwater protection program have been identified as key to the success in achieving the desired objectives. Key elements of the program have included early identification of all the potential sources for groundwater contamination, development of an overall strategy for waste site assessment and mitigation, use of a flexible computerized system for data base management, and establishing good relationships with regulatory agencies. 10 references, 6 figures, 4 tables

  11. 40 CFR 174.510 - Bacillus thuringiensis Cry1Ac protein in all plants; exemption from the requirement of a tolerance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Bacillus thuringiensis Cry1Ac protein in all plants; exemption from the requirement of a tolerance. 174.510 Section 174.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PROCEDURES AND REQUIREMENTS FOR PLANT-INCORPORATED PROTECTANTS Tolerances...

  12. 40 CFR 174.511 - Bacillus thuringiensis Cry1Ab protein in all plants; exemption from the requirement of a tolerance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Bacillus thuringiensis Cry1Ab protein in all plants; exemption from the requirement of a tolerance. 174.511 Section 174.511 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PROCEDURES AND REQUIREMENTS FOR PLANT-INCORPORATED PROTECTANTS Tolerances...

  13. Forum for fire protection and safety in power plants[Norway

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The conference contains 16 presentations on topics in the fields of fire protection and safety in plants in Western Norway, reorganization and reconstruction of power systems and plants in Norway, various aspects of risk and vulnerability analysis, technological aspects of plant management and construction and problems and risks with particularly transformers. Some views on challenges of the fire departments and the new Norwegian regulations for electrical power supply systems are included. One presentation deals with challenges for Icelandic power production plants.

  14. Plant invasions in protected areas of tropical pacific islands, with special reference to Hawaii

    Science.gov (United States)

    Hughes, R. Flint; Meyer, Jean-Yves; Loope, Lloyd L.

    2013-01-01

    Isolated tropical islands are notoriously vulnerable to plant invasions. Serious management for protection of native biodiversity in Hawaii began in the 1970s, arguably at Hawaii Volcanoes National Park. Concerted alien plant management began there in the 1980s and has in a sense become a model for protected areas throughout Hawaii and Pacific Island countries and territories. We review the relative successes of their strategies and touch upon how their experience has been applied elsewhere. Protected areas in Hawaii are fortunate in having relatively good resources for addressing plant invasions, but many invasions remain intractable, and invasions from outside the boundaries continue from a highly globalised society with a penchant for horticultural novelty. There are likely few efforts in most Pacific Islands to combat alien plant invasions in protected areas, but such areas may often have fewer plant invasions as a result of their relative remoteness and/or socio-economic development status. The greatest current needs for protected areas in this region may be for establishment of yet more protected areas, for better resources to combat invasions in Pacific Island countries and territories, for more effective control methods including biological control programme to contain intractable species, and for meaningful efforts to address prevention and early detection of potential new invaders.

  15. 2-Fluoro-L-Fucose Is a Metabolically Incorporated Inhibitor of Plant Cell Wall Polysaccharide Fucosylation.

    Directory of Open Access Journals (Sweden)

    Jose A Villalobos

    Full Text Available The monosaccharide L-fucose (L-Fuc is a common component of plant cell wall polysaccharides and other plant glycans, including the hemicellulose xyloglucan, pectic rhamnogalacturonan-I (RG-I and rhamnogalacturonan-II (RG-II, arabinogalactan proteins, and N-linked glycans. Mutations compromising the biosynthesis of many plant cell wall polysaccharides are lethal, and as a result, small molecule inhibitors of plant cell wall polysaccharide biosynthesis have been developed because these molecules can be applied at defined concentrations and developmental stages. In this study, we characterize novel small molecule inhibitors of plant fucosylation. 2-fluoro-L-fucose (2F-Fuc analogs caused severe growth phenotypes when applied to Arabidopsis seedlings, including reduced root growth and altered root morphology. These phenotypic defects were dependent upon the L-Fuc salvage pathway enzyme L-Fucose Kinase/ GDP-L-Fucose Pyrophosphorylase (FKGP, suggesting that 2F-Fuc is metabolically converted to the sugar nucleotide GDP-2F-Fuc, which serves as the active inhibitory molecule. The L-Fuc content of cell wall matrix polysaccharides was reduced in plants treated with 2F-Fuc, suggesting that this molecule inhibits the incorporation of L-Fuc into these polysaccharides. Additionally, phenotypic defects induced by 2F-Fuc treatment could be partially relieved by the exogenous application of boric acid, suggesting that 2F-Fuc inhibits RG-II biosynthesis. Overall, the results presented here suggest that 2F-Fuc is a metabolically incorporated inhibitor of plant cellular fucosylation events, and potentially suggest that other 2-fluorinated monosaccharides could serve as useful chemical probes for the inhibition of cell wall polysaccharide biosynthesis.

  16. Concept for the Emergency Protection in the Vicinity of Nuclear Power Plants

    International Nuclear Information System (INIS)

    1998-03-01

    In 1991, the Swiss Federal Nuclear Safety Inspectorate (HSK) issued a concept of the regulations for the cloud phase 1 of an nuclear power plant accident in Switzerland valid at that time in co-operation with the Federal Commission for AC Protection (KOMAC) and the Swiss Federal Nuclear Safety Commission (KSA). This concept replaced the version of 1977, which then formed the basis for emergency preparedness in Switzerland. Legal changes, such as the civil protection legislation and the ordinance on the distribution of iodine tablets to the population, as well as experience gained from the emergency exercises necessitated a revision of the existing concept. The present concept is issued by the Federal Commission for AC Protection (KOMAC) and deals with all phases of an accident sequence in a Swiss nuclear power plant focussing on the pre- and cloud phase. It also gives an overview of responsibilities and alert procedures for accidents at foreign nuclear power plants and other nuclear installations, as well as of accidents in connection with transportation of radioactive materials. The concept is designed to help the federal and cantonal authorities in the vicinity of nuclear power plants in charge of emergency protection in preparing their emergency procedure specifications, and in the realisation of the readiness for emergencies. Furthermore, it shall serve the cantons as a guideline for the preparation of emergency specifications for the communities. The concept is based on the assumption that the executive bodies and emergency forces provided for the general civil protection are employed in case of an accident at a nuclear power plant. (authors)

  17. Fault Transient Analysis and Protection Performance Evaluation within a Large-scale PV Power Plant

    Directory of Open Access Journals (Sweden)

    Wen Jinghua

    2016-01-01

    Full Text Available In this paper, a short-circuit test within a large-scale PV power plant with a total capacity of 850MWp is discussed. The fault currents supplied by the PV generation units are presented and analysed. According to the fault behaviour, the existing protection coordination principles with the plant are considered and their performances are evaluated. Moreover, these protections are examined in simulation platform under different operating situations. A simple measure with communication system is proposed to deal with the foreseeable problem about the current protection scheme in the PV power plant.

  18. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    Energy Technology Data Exchange (ETDEWEB)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables.

  19. Chemical form of technetium in corn (Zea mays) and the gastrointestinal absorption of plant-incorporated Tc by laboratory rats

    International Nuclear Information System (INIS)

    Garten, C.T. Jr.; Myttenaere, C.; Vandecasteele, C.M.; Kirchmann, R.; Van Bruwaene, R.

    1984-01-01

    The food chain availability of technetium incorporated into plant tissue, its chemical form in corn leaves, and the potential for gastrointestinal absorption of plant-incorporated technetium was investigated. Technetium-95m was incorporated into corn leaves via root uptake. Chemical fractionation of the /sup 95m/Tc in leaves showed that 60% was extractable with boiling ethanol and weak mineral acids. The remainder was associated with cell walls and was extractable by harsh chemical treatment. Gel permeation chromatography of the cytosol, indicated that 50% of the /sup 95m/Tc co-chromatographed with anionic pertechnetate; however, it was impossible to distinguish if this pure pertechnetate or technetium complexed with organic molecules. Technetium-95m was administered to laboratory rats in a single dose as: (1) intravenous injection of pertechnetate, (2) pertechnetate mixed with standard laboratory food, and (3) a meal containing /sup 95m/Tc biologically incorporated into corn leaves. High concentrations of /sup 95m/Tc were found in the thyroids, hair, kidneys, and liver of rats. Technetium rapidly disappeared from the liver, kidneys, and other tissues, but remained in the thyroids and hair. Urinary excretion of technetium decreased, and fecal excretion increased when technetium was fed to rats as a /sup 95m/Tc incorporated into corn leaves. The percent of the administered dose absorbed into thyroid gland and the kidneys was less when technetium was biologically incorporated into corn leaves than when pertechnetate was mixed with food. Biological incorporation of technetium into plants appears to reduce its potential for food chain transfer by decreasing its availability for gastrointestinal absorption. 5 references, 4 figures, 3 tables

  20. Herbicidal Activity of Coumarin When Applied as a Pre-plant Incorporated into Soil

    Directory of Open Access Journals (Sweden)

    Amir-Hossein NAZEMI

    2015-06-01

    Full Text Available Due to having a short half-life and novel site of action, the herbicidal potential of natural compounds are lionized. Coumarin is a secondary metabolite from Lavandula sp., family Lamiacae. The impact of eight concentrations of coumarin (0, 100, 200, 400, 800, 1600, 3200 and 6400 ppm were separately used as a pre-plant incorporated into soil on six plant species under greenhouse conditions. Generally, coumarin had phytotoxic effect against all plant species. The phytotoxic effect was concentration-dependent. The high concentrations could inhibit the emergence of seedlings (probably by stopping germination of seeds. Based on ED50 parameter, the ranking of plant species for tolerance to coumarin was S. halepense > Z. mays > C. album > A. retroflexus > E. cruss-gali > P. oleracea. Based on selectivity index, coumarin at a concentration of 365.69 ppm can control P. oleracea without damaging Z. mays, whereas any concentration it cannot control other weeds without damaging Z. mays.

  1. Cooperation of nuclear, thermal and hydroelectric power plants in the power system

    International Nuclear Information System (INIS)

    1984-01-01

    The conference heard 36 papers of which 23 were incorporated in INIS. The subjects discussed were: the development of power industry in Czechoslovakia, methods of statistical analysis of data regarding nuclear power plant operation, the incorporation of WWER nuclear power plants in the power supply system, the standardization of nuclear power plants, the service life of components, use of nuclear energy sources, performance of the reactor accident protection system, the use of nuclear power and heating plants in Hungary, risk analysis, optimization of nuclear power plants, accidents caused by leakage of the primary and secondary circuit. (J.P.)

  2. A study of a high temperature nuclear power plant incorporating a non-integrated indirect cycle gas turbine

    International Nuclear Information System (INIS)

    Sarlos, G.; Helbling, W.; Zollinger, E.; Gregory, N.; Luchsinger, H.

    1982-04-01

    In connection with the HHT-project, the Swiss Federal Institute for Reactor Research has performed a study of a 1640-MWth HTR-plant incorporating a non-integrated indirect cycle gas turbine with two-stage intercooling, as a possibility of simplifying and reducing the cost of the HHT-demonstration plant. In this paper, the plant design is described and compared with the HHT-demonstration plant (a CCGT integrated plant with single stage intercooling). Also included is an evaluation of the various advantages and disadvantages of this design together with the presentation of some of the sensitivity results. (Auth.)

  3. Report on task I: fire protection system study

    International Nuclear Information System (INIS)

    Bernard, E.A.; Cano, G.L.

    1977-02-01

    This study (1) evaluates, on a comparative basis, the national and international regulatory and insurance standards that serve as guidance for fire protection within the nuclear power industry; (2) analyzes the recommendations contained in the major reports on the Browns Ferry Fire; (3) proposes quantitative safety goals and evaluation methods for Nuclear Power Plant Fire Protection Systems (NPPFPS); (4) identifies potential improvements that may be incorporated into NPPFPS; and (5) recommends a plan of action for continuation of the fire protections systems study

  4. Ecosystem-Based Incorporation of Nectar-Producing Plants for Stink Bug Parasitoids

    Directory of Open Access Journals (Sweden)

    Glynn Tillman

    2017-06-01

    Full Text Available Adult parasitoids of pest insects rely on floral resources for survival and reproduction, but can be food-deprived in intensively managed agricultural systems lacking these resources. Stink bugs are serious pests for crops in southwest Georgia. Provisioning nectar-producing plants for parasitoids of stink bugs potentially can enhance biocontrol of these pests. Knowledge of spatial and temporal availability and distribution of stink bugs in host plants is necessary for appropriate timing and placement of flowering plants in agroecosystems. Stink bugs move between closely associated host plants throughout the growing season in response to deteriorating suitability of their host plants. In peanut-cotton farmscapes, stink bugs develop in peanut, and subsequently the adults disperse into adjacent cotton. Parasitism of Nezara viridula (L. adults by Trichopoda pennipes (F. at the peanut-cotton interface was significantly higher in cotton with a strip of milkweed or buckwheat between the two crops than in cotton alone. Milkweed and buckwheat also provided nectar to a wide range of insect pollinators. Monarch butterflies fed on milkweed. When placed between peanut and cotton, a strip of soybean was an effective trap crop for cotton, reducing economic damage. Incorporation of buckwheat near soybean enhanced parasitism of Euschistus servus (Say eggs by Telenomus podisi Ashmead in cotton. In conclusion, nectar provision enhances biocontrol of stink bugs, acts together with other management tactics for stink bug control, and aids in conservation of natural enemies, insect pollinators, and the monarch butterfly.

  5. ECOTOXICITY AND PHYTOTOXICITY OF PLANT PROTECTION PRODUCTS TO RHIZOSPHERE FUNGI AND WINTER WHEAT SEEDLINGS

    Directory of Open Access Journals (Sweden)

    Anna Daria Stasiulewicz-Paluch

    2015-11-01

    Full Text Available Registration of plant protection products involves the analysis of their effects on soil microorganisms. The residues of plant protection products penetrate the soil, but their impact on fungi remains scarcely researched. In this study, the influence of selected plant protection products on the abundance of rhizosphere-dwelling fungi and the growth of winter wheat seedlings was evaluated under greenhouse conditions. The analysed plant protection products had an inhibitory effect on the growth of filamentous fungi in the rhizosphere, whereas yeasts were resistant to those products applied to soil. Tebuconazole exerted the strongest suppressive effect on the growth of filamentous fungi, and propiconazole was characterized by the greatest phytotoxic activity against winter wheat seedlings. Azoxystrobin had the weakest ecotoxic and phytotoxic effects, and its application to soil usually led to a rapid increase in the counts of fungi of the genus Acremonium.

  6. Protective action alternatives for accidents at nuclear power plants

    International Nuclear Information System (INIS)

    Tingle, A.; Pratt, W.T.; McGuire, S.A.

    1987-06-01

    Protective action calculations have been performed for five different light water reactors (LWRs) and containment designs using high and low fission product releases for early and late containment failures for each plant. These fission product release estimates were obtained from studies performed for the recently published ''Reactor Risk Reference Document'' (NUREG-1150). Five protective actions were considered for the risks of exceeding various dose levels to the red marrow versus centerline distance from the plants using site-specific meteorology. The strategies considered were 4 hours of normal activity, basement sheltering, large building sheltering, evacuation at release, and evacuation 1 hour after release. The evacuations were computed using 10 mph evacuation speed for all sites. Additional calculations were performed for the dose contributions due to the cloud, ground, and inhalation pathways

  7. Regulatory inspections in nuclear plants in the field of radiation protection

    International Nuclear Information System (INIS)

    Hort, M.; Fuchsova, D.

    2014-01-01

    State Office for Nuclear Safety executes state administration and performs inspections at peaceful use of nuclear energy and ionizing radiation in the field of radiation protection and nuclear safety. Inspections on radiation protection at nuclear power plants are secured by inspectors of the Department of Radiation Protection in Fuel Cycle, who work at the Regional centre Brno and Ceske Budejovice. (authors)

  8. Fire protection programme during construction of the Chashma nuclear power plant

    International Nuclear Information System (INIS)

    Mian Umer, M.

    1998-01-01

    A clear view is given of several measures that have been taken with regard to fire prevention, protection and fire fighting during all phases of the construction, installation and commissioning of the Chasma nuclear power plant to protect personnel and equipment so that any delays in plant operation as a result of fire incident can be avoided. These measures include the precautions taken, the provisions made for fire extinguishers and hydrants, and the setting up of a fire brigade. An overview is also given of the fire incidents that have occurred. (author)

  9. Fire protection guidelines for nuclear power plants, June 1976

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Guidelines acceptable to the NRC staff for implementing in the development of a fire protection program for nuclear power plants. The purpose of the fire protection program is to ensure the capability to shut down the reactor and maintain it in a safe shutdown condition and to minimize radioactive releases to the environment in the event of a fire. If designs or methods different from the guidelines presented herein are used, they must provide fire protection comparable to that recommended in the guidelines. Suitable bases and justification should be provided for alternative approaches to establish acceptable implementation of General Design Criterion 3

  10. Man as a protective barrier in nuclear power plants

    International Nuclear Information System (INIS)

    Fechner, J.B.

    1980-01-01

    Evaluation of nuclear power plant incidents frequently reveals man as a major element of risk. Yet, in a nuclear power plant man has the function of an important protective barrier, either by maintaining the plant, by detecting and limiting faults or incidents, or by taking proper measures in accidents. This is true despite, or perhaps because of, the high degree of plant automation. For this reason, it is indispensable that a high level of engineered plant safeguards be accompanied by a minimum of faults contributed by human action. This implies that the staff and their working conditions must meet the same stringent safety requirements as the nuclear power plant proper. Reactor manufacturers, nuclear power plant operators and the responsible authorities try to optimize this human contribution. The Federal Ministry of the Interior, through its Special Technical Guidelines and its continuation training measures, occupies an important position in this respect. Further measures and ordinances are being prepared by that Ministry. (orig.) [de

  11. Engineered chitosan based nanomaterials: Bioactivities, mechanisms and perspectives in plant protection and growth.

    Science.gov (United States)

    Kumaraswamy, R V; Kumari, Sarita; Choudhary, Ram Chandra; Pal, Ajay; Raliya, Ramesh; Biswas, Pratim; Saharan, Vinod

    2018-07-01

    Excessive use of agrochemicals for enhancing crop production and its protection posed environmental and health concern. Integration of advanced technology is required to realize the concept of precision agriculture by minimizing the input of pesticides and fertilizers per unit while improving the crop productivity. Notably, chitosan based biodegradable nanomaterials (NMs) including nanoparticles, nanogels and nanocomposites have eventually proceeded as a key choice in agriculture due to their inimitable properties like antimicrobial and plant growth promoting activities. The foreseeable role of chitosan based NMs in plants might be in achieving sustainable plant growth through boosting the intrinsic potential of plants. In-spite of the fact that chitosan based NMs abode immense biological activities in plants, these materials have not yet been widely adopted in agriculture due to poor understanding of their bioactivity and modes of action towards pathogenic microbes and in plant protection and growth. To expedite the anticipated claims of chitosan based NMs, it is imperative to line up all the possible bioactivities which denote for sustainable agriculture. Herein, we have highlighted, in-depth, various chitosan based NMs which have been used in plant growth and protection mainly against fungi, bacteria and viruses and have also explained their modes of action. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. 40 CFR 76.4 - Incorporation by reference.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Incorporation by reference. 76.4 Section 76.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.4 Incorporation by reference. (a) The...

  13. Estimation of reliability on digital plant protection system in nuclear power plants using fault simulation with self-checking

    International Nuclear Information System (INIS)

    Lee, Jun Seok; Kim, Suk Joon; Seong, Poong Hyun

    2004-01-01

    Safety-critical digital systems in nuclear power plants require high design reliability. Reliable software design and accurate prediction methods for the system reliability are important problems. In the reliability analysis, the error detection coverage of the system is one of the crucial factors, however, it is difficult to evaluate the error detection coverage of digital instrumentation and control system in nuclear power plants due to complexity of the system. To evaluate the error detection coverage for high efficiency and low cost, the simulation based fault injections with self checking are needed for digital instrumentation and control system in nuclear power plants. The target system is local coincidence logic in digital plant protection system and a simplified software modeling for this target system is used in this work. C++ based hardware description of micro computer simulator system is used to evaluate the error detection coverage of the system. From the simulation result, it is possible to estimate the error detection coverage of digital plant protection system in nuclear power plants using simulation based fault injection method with self checking. (author)

  14. Part 2: Conserving and Planting Trees at Development Sites

    Science.gov (United States)

    Karen Cappiella; Tom Schueler; Tiffany Wright

    2006-01-01

    This manual presents specific ways to enable developers, engineers or landscape architects to incorporate more trees into a development site. The proposed approach focuses on protecting existing trees, planting trees in storm water treatment practices, and planting trees in other open spaces at the development site. This manual introduces conceptual designs for storm...

  15. Radiation protection aspects in decommissioning of a fuel reprocessing plant

    International Nuclear Information System (INIS)

    Kotrappa, P.; Joshi, P.P.; Theyyunni, T.K.; Sidhwa, B.M.; Nadkarni, M.N.

    1980-01-01

    The decontamination of a fuel reprocessing plant which underwent partial decommissioning is described. The following radiation protection aspects of the work are discussed: dismantling and removal of process vessels, columns and process off-gas filters; decontamination of various process areas; and management of liquid and solid wastes. The work was completed safely by using personnel protective equipment such as plastic suits and respirators (gas, particulate and fresh air). Total dose commitment for this work was around 3000 man-rems, including dose received by staff for certain jobs related to the operation of a section of the plant. The external dose was kept below the annual limit of 5000 mrems for any individual. No internal contamination incident occurred which caused a dose commitment in excess of 10% of the annual limit. The fact that all the work was completed by the staff normally associated with the operation of the plant contributed significantly to the management and control of personnel exposures. (H.K.)

  16. NON-TARGET AND ECOSYSTEM IMPACTS FROM GENETICALLY MODIFIED CROPS CONTAINING PLANT INCORPORATED PROTECTANTS (PIPS)

    Science.gov (United States)

    The risk of unintended and unexpected adverse impacts on non-target organisms and ecosystems is a key issue in environmental risk assessment of PIP crop plants. While there has been considerable examination of the effects of insect resistant crops on certain non-target organisms...

  17. Fish scale collagen sponge incorporated with Macrotyloma uniflorum plant extract as a possible wound/burn dressing material.

    Science.gov (United States)

    Muthukumar, Thangavelu; Prabu, P; Ghosh, Kausik; Sastry, Thotapalli Parvathaleswara

    2014-01-01

    Application of plant extracts for the burn/wound treatment is followed over the decades as a common practice and it is an important aspect in clinical management. In this study porous collagen sponges (CS) were prepared using fish scales and were incorporated with mupirocin (CSM) and extracts of Macrotyloma uniflorum (CSPE) separately to impart antimicrobial activity to the sponges. The results showed that the addition of plant extract increased the tensile strength of CSPE and stability against collagenase enzyme. FTIR studies have shown the incorporation of plant extract in CSPE, SEM studies have revealed the porous nature of the sponges and XRD patterns have shown the retention of collagen triple helical structure even after the addition of plant extract. CSPE and CSM have exhibited antimicrobial properties. The sponges prepared were analysed for their in vitro biocompatibility studies using fibroblasts and keratinocyte cell lines and the results have shown their biocompatible nature. Based on the results obtained, CS, CSM and CSPE may be tried as a burn/wound dressing materials, initially, in small animals in vivo. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Component protection based automatic control

    International Nuclear Information System (INIS)

    Otaduy, P.J.

    1992-01-01

    Control and safety systems as well as operation procedures are designed on the basis of critical process parameters limits. The expectation is that short and long term mechanical damage and process failures will be avoided by operating the plant within the specified constraints envelopes. In this paper, one of the Advanced Liquid Metal Reactor (ALMR) design duty cycles events is discussed to corroborate that the time has come to explicitly make component protection part of the control system. Component stress assessment and aging data should be an integral part of the control system. Then transient trajectory planning and operating limits could be aimed at minimizing component specific and overall plant component damage cost functions. The impact of transients on critical components could then be managed according to plant lifetime design goals. The need for developing methodologies for online transient trajectory planning and assessment of operating limits in order to facilitate the explicit incorporation of damage assessment capabilities to the plant control and protection systems is discussed. 12 refs

  19. Chemical plant protection outlays in vast areas farming at the beginning of 21st century

    Directory of Open Access Journals (Sweden)

    Maria Golinowska

    2009-01-01

    Full Text Available In 2008, several investigations were conducted in the area of chemical plant protection outlays in two vast area farms where simplified system of farming was applied. Analysed outlays consisted of: use of pesticides in kilograms of active substance per 1 ha and real costs of plant protection procedures. Profitability of the outlay was identified with approximate indicator of outlay E1 and E2. The research showed that farm during plant production use from 1 to 10.28 kg AS/ha. Costs of these procedures ranged from 100.50 to 1253.84 PLN/ha depending on the cultivated plant. Profitability of plant protection procedures in wheat and rape cultivation was at the same level in both farms. The highest profitability was reached by maize cultivation.

  20. Recent digital control and protection retrofits in power plants

    International Nuclear Information System (INIS)

    Fournier, R.D.; Hammer, M.; Smith, J.E.

    1987-01-01

    Digital computers are now being retrofitted to all types of power plants, replacing analog equipment and solving problems such as equipment obsolescence and low reliability. Three diverse examples of retrofits are presented in this paper, representing trends in man/machine interface design at an oil-fired plant, protection system in pressurized heavy-water reactors, and control systems in light water reactors (LWRs). The examples have been chosen to illustrate diverse reasons for the retrofits and the benefits derived. The cases presented report retrofits at Northern States Power's Monticello boiling water reactor, New Brunswick Electric Power Commission's (NBEPC's) Point Lepreau Nuclear Generating Station, and finally NBEPC's oil-fired plant at Courtney Bay

  1. Flood protection of Crystal River Unit 3 Nuclear Plant

    International Nuclear Information System (INIS)

    Noble, R.M.; Simpson, B.

    1975-01-01

    To satisfy U.S. Atomic Energy Commission (AEC) safety criteria, a required evaluation of the worst site-related flood is performed for the Crystal River Plant, located on the Gulf Coast of Florida, the probable maximum stillwater flood levels are likely to be a result of the probable maximum hurricane. Flood protection requirements for the Crystal River Plant are determined by considering the most severe combination of probable maximum hurricane parameters for the Gulf Coast Region. These parameters are used as input to a model of hurricane surge generation and attendant wave activity in order to determine the maximum flood levels at the Crystal River Plant. 4 refs

  2. Reliability Analysis Study of Digital Reactor Protection System in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Guo, Xiao Ming; Liu, Tao; Tong, Jie Juan; Zhao, Jun

    2011-01-01

    The Digital I and C systems are believed to improve a plants safety and reliability generally. The reliability analysis of digital I and C system has become one research hotspot. Traditional fault tree method is one of means to quantify the digital I and C system reliability. Review of advanced nuclear power plant AP1000 digital protection system evaluation makes clear both the fault tree application and analysis process to the digital system reliability. One typical digital protection system special for advanced reactor has been developed, which reliability evaluation is necessary for design demonstration. The typical digital protection system construction is introduced in the paper, and the process of FMEA and fault tree application to the digital protection system reliability evaluation are described. Reliability data and bypass logic modeling are two points giving special attention in the paper. Because the factors about time sequence and feedback not exist in reactor protection system obviously, the dynamic feature of digital system is not discussed

  3. System and Software Design for the Plant Protection System for Shin-Hanul Nuclear Power Plant Units 1 and 2

    International Nuclear Information System (INIS)

    Hwang, In Seok; Kim, Young Geul; Choi, Woong Seock; Sohn, Se Do

    2015-01-01

    The Reactor Protection System(RPS) protects the core fuel design limits and reactor coolant system pressure boundary for Anticipated Operational Occurrences (AOOs), and provides assistance in mitigating the consequences of Postulated Accidents (PAs). The ESFAS sends the initiation signals to Engineered Safety Feature - Component Control System (ESF-CCS) to mitigate consequences of design basis events. The Common Q platform Programmable Logic Controller (PLC) was used for Shin-Wolsung Nuclear Power Plant Units 1 and 2 and Shin-Kori Nuclear Power Plant Units 1, 2, 3 and 4 since Digital Plant Protection System (DPPS) based on Common Q PLC was applied for Ulchin Nuclear Power Plant Units 5 and 6. The PPS for Shin-Hanul Nuclear Power Plant Units 1 and 2 (SHN 1 and 2) was developed using POSAFE-Q PLC for the first time for the PPS. The SHN1 and 2 PPS was delivered to the sites after completion of Man Machine Interface System Integrated System Test (MMIS-IST). The SHN1 and 2 PPS was developed to have the redundancy in each channel and to use the benefits of POSAFE-Q PLC, such as diagnostic and data communication. The PPS application software was developed using ISODE to minimize development time and human errors, and to improve software quality, productivity, and reusability

  4. System and Software Design for the Plant Protection System for Shin-Hanul Nuclear Power Plant Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Seok; Kim, Young Geul; Choi, Woong Seock; Sohn, Se Do [KEPCO EnC, Daejeon (Korea, Republic of)

    2015-10-15

    The Reactor Protection System(RPS) protects the core fuel design limits and reactor coolant system pressure boundary for Anticipated Operational Occurrences (AOOs), and provides assistance in mitigating the consequences of Postulated Accidents (PAs). The ESFAS sends the initiation signals to Engineered Safety Feature - Component Control System (ESF-CCS) to mitigate consequences of design basis events. The Common Q platform Programmable Logic Controller (PLC) was used for Shin-Wolsung Nuclear Power Plant Units 1 and 2 and Shin-Kori Nuclear Power Plant Units 1, 2, 3 and 4 since Digital Plant Protection System (DPPS) based on Common Q PLC was applied for Ulchin Nuclear Power Plant Units 5 and 6. The PPS for Shin-Hanul Nuclear Power Plant Units 1 and 2 (SHN 1 and 2) was developed using POSAFE-Q PLC for the first time for the PPS. The SHN1 and 2 PPS was delivered to the sites after completion of Man Machine Interface System Integrated System Test (MMIS-IST). The SHN1 and 2 PPS was developed to have the redundancy in each channel and to use the benefits of POSAFE-Q PLC, such as diagnostic and data communication. The PPS application software was developed using ISODE to minimize development time and human errors, and to improve software quality, productivity, and reusability.

  5. 40 CFR 174.524 - Glyphosate Oxidoreductase GOX or GOXv247 in all plants; exemption from the requirement of a...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Glyphosate Oxidoreductase GOX or... REQUIREMENTS FOR PLANT-INCORPORATED PROTECTANTS Tolerances and Tolerance Exemptions § 174.524 Glyphosate... Glyphosate Oxidoreductase GOX or GOXv247 enzyme in all plants are exempt from the requirement of a tolerance...

  6. An analysis of the development and application of plant protection UAV based on advanced materials

    Science.gov (United States)

    Huang, Yuan-hui; Wei, Neng; Quan, Zhi-cheng; Huang, Yu-rong

    2018-06-01

    The development and application of a number of advanced materials plant protection unmanned aerial vehicle (UAV) is an important part of the comprehensive production of agricultural modernization. The paper is taken as an example of Guangxi No. 1 agricultural service aviation science and Technology Co., Ltd. This paper introduces the internal and external environment of the research and development of the plant protection UAV for the advanced materials of the company. The external environment focuses on the role of the plant protection UAV on the development of the agricultural mechanization; the internal environment focuses on the advantages of the UAV in technology research, market promotion and application, which is imperative. Finally, according to the background of the whole industry, we put forward some suggestions for the developing opportunities and challenges faced by plant protection UAV, hoping to proving some ideas for operators, experts and scholars engaged in agricultural industry.

  7. Modelling of core protection and monitoring system for PWR nuclear power plant simulator

    International Nuclear Information System (INIS)

    Jung Kun Lee; Byoung Sung Han

    1997-01-01

    A nuclear power plant simulator was developed for Younggwang units 3 and 4 nuclear power plant (YGN Nos 3 and 4) in Korea; it has been in operation on training center since November 1996. The core protection calculator (CPC) and the core operating limit supervisory system (COLSS) for the simulator were also developed. The CPC is a digital computer-based core protection system, which performs on-line calculation of departure from nucleate boiling ratio (DNBR) and local power density (LPD). It initiates reactor trip when the core conditions exceed designated DNBR or LPD limitations. The COLSS is designed to assist operators by implementing the limiting conditions for operations in the technical specifications. With these systems, it is possible to increase capacity factor and safety of nuclear power plants, because the COLSS data can show accurate operation margin to plant operators and the CPC can protect reactor core. In this study, the function of CPC/COLSS is analyzed in detail, and then simulation model for CPC/COLSS is presented based on the function. Compared with the YGN Nos 3 and 4 plant operation data and CEDIPS/COLSS FORTRAN code test results, the predictions with the model show reasonable results. (Author)

  8. Protection against internal fires and explosions in the design of nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Experience of the past two decades in the operation of nuclear power plants and modern analysis techniques confirm that fire may be a real threat to nuclear safety and should receive adequate attention from the beginning of the design process throughout the life of the plant. Within the framework of the NUSS programme, a Safety Guide on fire protection had therefore been developed to enlarge on the general requirements given in the Code. Since its first publication in 1979, there has been considerable development in protection technology and analysis methods and after the Chernobyl accident it was decided to revise the existing Guide. This Safety Guide supplements the requirements established in Safety of Nuclear Power Plants: Design. It supersedes Safety Series No. 50-SG-D2 (Rev. 1), Fire Protection in Nuclear Power Plants: A Safety Guide, issued in 1992.The present Safety Guide is intended to advise designers, safety assessors and regulators on the concept of fire protection in the design of nuclear power plants and on recommended ways of implementing the concept in some detail in practice

  9. SEVESO: which protections for plants?

    International Nuclear Information System (INIS)

    Jouette, Isabelle

    2015-01-01

    As some recent incidents resulted in a decision to strengthen the control of SEVESO-classified sites in order to prevent malevolent and terrorist acts, this article recalls the origin of the SEVESO directive which aims at preventing major industrial risks, briefly indicates organisational measures which must me implemented on these sites (1171 sites are classified in France, an 670 as particularly dangerous), and measures taken after an explosion in a petrochemical plant in southern France (in Berre). The next part proposes an overview of the legal context and measures of protection of nuclear installations against malevolent acts, as these installations are outside the scope of the Seveso directive but depend on a specific regulation

  10. Increase of power and efficiency of the 900 MW supercritical power plant through incorporation of the ORC

    Science.gov (United States)

    Ziółkowski, Paweł; Mikielewicz, Dariusz; Mikielewicz, Jarosław

    2013-12-01

    The objective of the paper is to analyse thermodynamical and operational parameters of the supercritical power plant with reference conditions as well as following the introduction of the hybrid system incorporating ORC. In ORC the upper heat source is a stream of hot water from the system of heat recovery having temperature of 90 °C, which is additionally aided by heat from the bleeds of the steam turbine. Thermodynamical analysis of the supercritical plant with and without incorporation of ORC was accomplished using computational flow mechanics numerical codes. Investigated were six working fluids such as propane, isobutane, pentane, ethanol, R236ea and R245fa. In the course of calculations determined were primarily the increase of the unit power and efficiency for the reference case and that with the ORC.

  11. Human cultured cells are capable to incorporate isolated plant mitochondria loaded with exogenous DNA

    Directory of Open Access Journals (Sweden)

    Laktionov P. P.

    2012-07-01

    Full Text Available Aim. To investigate the possibility of human cultured cells to incorporate isolated mitochondria together with exogenous DNA introduced into organelles. Methods. Two approaches were used for this purpose, fluorescent labelling of mitochondria and/or DNA with subsequent analysis of the cells subjected to incubation by microscopy or by quantitative PCR. Results. We have shown that human cultured cells lines, HeLa and HUVEC, are capable to uptake isolated plant mitochondria and that this process depends on the incubation time and concentration of organelles present in medium. The incorporated mitochondria can serve as vehicles to deliver exogenous DNA into human cells, this DNA is then distributed in different cell compartments. Conclusions. These results are preliminary and need further investigations, including testing the possibility of human cells to incorporate the mitochondria of human or animal origin and creating genetic construction which could provide certain selectivity or stability of the transferred exogenous DNA upon cell uptake of the mitochondria as vectors.

  12. Guidelines for training and qualification of radiological protection technicians

    International Nuclear Information System (INIS)

    1987-08-01

    These guidelines, used in combination with plant-specific job analysis, provide the framework for a training and qualification program for radiological protection technicians at nuclear power plants. Radiological protection technicians are defined as those individuals, both plant and contractor, who will be engaged in the evaluation of radiological conditions in the nuclear plant and the implementation of the necessary radiological safety measures as they apply to nuclear plant workers and members of the general public. An important aspect of this work is recognizing and handling unusual situations involving radioactivity, including incidents related to degraded core conditions. These guidelines incorporate the results of an industry-wide job analysis and task analysis (JTA) combined with industry operating experience review. However, the industry-wide analyses did not identify all important academic and fundamental knowledge and skills. Further in-depth analysis by subject matter experts produced additional knowledge and skills that were added to these guidelines. All utilities should use these guidelines in conjunction with plant-specific and industry-wide JTA results to develop or validate their radiological protection technician training program. Plant-specific information should be used to establish appropriate training program content. This plant-specific information should reflect unique job duties, equipment, operating experience, and trainee entry-level qualifications. Revisions to these guidelines should be reviewed for applicability and incorporated into the training program using each utility's training system development (TSD) procedures. Plant-specific job analysis and task analysis data is essential to the development of performance-based training programs. These analyses are particularly useful in selecting tasks for training and in developing on-the-job training (OJT), laboratory training, and mock-up training. Qualification programs based on these

  13. Organisation of radiation protection at Sizewell Nuclear Power Plant in the UK. Report n. 290

    International Nuclear Information System (INIS)

    Crouail, P.; Jeannin, B.; Lefaure, C.; Panisset, L.

    2004-01-01

    This report first describes the organisation and management of radiation protection at Sizewell Nuclear Power Plant (UK): general organisation, organisation of the radiation protection department, goals of radiation protection at plant and corporate levels, measurement of radiation protection performance, presence of health physicists in the plant, national and international comparisons. Then, it addresses the training of workers and radiation protection specialists with respect to radiation protection, the management of zoning and surveillance (action to address the radiation risk and the contamination risk). It describes the relationships of Health physicists with contractors and other workers teams, and the relationships with safety authorities. It indicates the different outages of this organisation: general planning, information sheets, physicists work planning, reviews and meetings. It describes the management of personal dosimetry with radiation work permits and actions aimed at the reduction of doses during various operations. The last part proposes a feedback experience report and evokes the generated database, and addresses events reporting

  14. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    International Nuclear Information System (INIS)

    1993-01-01

    The DOE has mandated in DOE Order 5400.1 that its operations will be conducted in an environmentally safe manner. The Waste Isolation Pilot Plant (WIPP) will comply with DOE Order 5400.1 and will conduct its operations in a manner that ensures the safety of the environment and the public. This document outlines how the WIPP will protect and preserve groundwater within and surrounding the WIPP facility. Groundwater protection is just one aspect of the WIPP environmental protection effort. The WIPP groundwater surveillance program is designed to determine statistically if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will be determined and appropriate corrective action initiated

  15. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Washington TRU Solutions

    2002-09-24

    U.S. Department of Energy (DOE) Order 5400.1, General Environmental Protection Program, requires each DOE site to prepare a Groundwater Protection Management Program Plan. This document fulfills the requirement for the Waste Isolation Pilot Plant (WIPP). This document was prepared by the Hydrology Section of the Westinghouse TRU Solutions LLC (WTS) Environmental Compliance Department, and it is the responsibility of this group to review the plan annually and update it every three years. This document is not, nor is it intended to be, an implementing document that sets forth specific details on carrying out field projects or operational policy. Rather, it is intended to give the reader insight to the groundwater protection philosophy at WIPP.

  16. Program of social protection for Chornobyl nuclear power plant staff and Slavutich town residents in the aftermath of the plant shutdown

    International Nuclear Information System (INIS)

    Komarov, V.A.

    2001-01-01

    In order to solve social issues related to ChNPP shutdown, the Ukrainian Government approved 'Program of Social Protection for Chornobyl Nuclear Power Plant Staff and Slavutich Town Residents in Aftermath of Plant Shutdown' on 29 November 2000. The Program Objective is to ensure social protection and support of well being of ChNPP staff and Slavutich town residents after the plant shutdown. Preserve and develop town infrastructure. Create compensatory jobs; efficiently manage human resources; provide social allowances and guarantees to the ChNPP staff that is being released, and Slavutich town residents

  17. Proposal for guidelines for the physical protection of nuclear materials, plants and transports in Denmark

    International Nuclear Information System (INIS)

    1978-03-01

    The guidelines are based on recommendations in the IAEA's ''Physical Protection of Nuclear Material,'' INFCIRC/225/rev.1. In accordance with practice in other countries, the guidelines give more detailed requirements for the protection of reactor plants than those given in the IAEA's present recommendations, which put more emphasis on the protection of nuclear materials. The measures to be taken for nuclear plants, or nuclear transports, are proposed made to fit the potential risk that the more closely defined actions imply. It is suggested that the more detailed rules for the scope of the protection of plants or materials should be laid down by the National Agency on the basis of recommendations made by the Inspectorate of Nuclear Installations, which in turn are based on the safety documentation of the plant/material owners. It is further proposed that the National Agency, again on a recommendation from the Inspectorate, should lay down more detailed guidelines for the reporting of changes in stocks or transports of nuclear materials. (author)

  18. Application of Digital Technology for the Plant Protection System in Ulchin Nuclear Power Plant Units 5 and 6

    International Nuclear Information System (INIS)

    Deucksoo, Lee; Insik, Kim

    2006-01-01

    Since the completion of construction of Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4), the first units of the OPR (Optimized Power Reactor) series, various advanced design features have been incorporated to the following OPRs. The Ulchin Nuclear Power Plant Units 5 and 6(UCN 5 and 6) which started commercial operation in Korea from 2004 and 2005 respectively, are designed to provide improvements in safety, reliability and costs by applying both advanced proven technology and experiences gained from the construction and operation of the previous OPRs. Among those improvements, the digital plant protection system (DPPS) and the digital engineered safety feature actuation system (DESFAS) are the key elements to the UCN 5 and 6 designs. The DPPS and DESFAS utilizing the digital computer technology offer a solution to the obsolescence problem of analog system. These features also provide the potential for additional benefits such as ease of maintenance, increased performance, reduction of internal and external cross channel wiring, improvement of the surveillance testability and flexibility of control logic programming change. During the initial design stage, the Korean regulatory body had evaluated these design concepts intensively and concluded it to be acceptable for the safety point of view. Also, in-depth review on the detailed design and the special evaluation/audit for the software design process has been performed to secure the quality of the software. As a result, every issue raised during licensing review has been clarified and the operating licenses for the UCN 5 and 6 were issued in October, 2003 and October, 2004 respectively, by the government. In this paper, design characteristics of the UCN 5 and 6 are introduced, and advanced design features and implementation process are presented focused on the DPPS/DESFAS with some benefit analysis results. (authors)

  19. Plant protection under conditions of radioactive contamination of agricultural lands

    International Nuclear Information System (INIS)

    Filipas, A.S.; Oulianenko, L.N.; Pimenov, E.P.

    1995-01-01

    Increasing influence of anthropogenic contaminants as well as substantiated risk of the action of ionizing radiation on agroecosystems suggest the necessity of studying both the state of separate components of cenosis and search for methods on retention of ecosystem stability as a whole. In this case it should be taken into account that by retention of resistance of living organisms to the action of stress agents not only genetically conditioned potential but induction of protective reactions at the expense of ecogene action is of deciding significance as well. Protection of agricultural plants on the territories subjected to radioactive contamination resulting from the ChNPP accident brings attention of research works to a series of problems, the main one being the minimization of pesticide use by the total ecologization of technological processes, in plant growing. But an ordinary discontinuance of conducting protective chemical measures leads to growth in the number of harmful organisms in crop sowings and as a consequence an increase of crop loss and decrease of its quality. It is possible to solve this problem by introduction of measures increasing the resistance of agricultural plants to the action of unfavorable factors of environment. Application of biologically active substances (BAS) of natural and synthetic nature for incrustation of seeds fits into these methods. For the territories with increased content of radionuclides and especially by their rehabilitation the methods of preventive treatments directed to retarding the development of harmful organisms in crop sowings and excluding subsequent technological operations on chemical protection of sowings takes on special significance as it is directly connected with the problem of radiation burden on workers of agroindustrial complex

  20. Optimization of radiological protection in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    O'Donnell, P.; Amor, I.; Butragueno, J.L.

    1997-01-01

    Optimizing the radiological protection of occupationally exposed nuclear power plant workers has become one further item in what is called the safety culture. Spanish facilities are implementing programme with this in mind, grounded on a personal motivation policy with the backing of a suitable organizational structure. (Author)

  1. Protected-area boundaries as filters of plant invasions

    Czech Academy of Sciences Publication Activity Database

    Foxcroft, L. C.; Jarošík, Vojtěch; Pyšek, Petr; Richardson, D. M.; Rouget, M.

    2010-01-01

    Roč. 25, č. 2 (2010), s. 400-405 ISSN 0888-8892 R&D Projects: GA MŠk LC06073; GA ČR GA206/09/0563 Grant - others: European Comission(XE) KBBE-212459 Institutional research plan: CEZ:AV0Z60050516 Keywords : protected areas * invasive plants * Kruger National Park Subject RIV: EF - Botanics Impact factor: 4.894, year: 2010

  2. Variation in the effectiveness of biotic defence: the case of an opportunistic ant-plant protection mutualism.

    Science.gov (United States)

    Giusto, Bruno; Anstett, Marie-Charlotte; Dounias, Edmond; McKey, Doyle B

    2001-11-01

    Benefits to plants in facultative ant protection mutualisms are highly variable. This allows examination of the sources of this variation and the mechanisms by which ants protect plants. We studied opportunistic interactions between ants and an extrafloral nectary-bearing vine, Dioscorea praehensilis, during 3 different years. Variation in plant protection among years was striking. Several factors affected the effectiveness of the biotic defence. Stems recently emerged from the underground tuber were self-supporting, contacting no other plants and encountering few foraging ants. Stems then became lianescent, and contact with supporting plants greatly increased ant recruitment. Both species and number of ant workers influenced the effect of ants on the major herbivore, the chrysomelid beetle Lilioceris latipennis. Protective actions included limitation of oviposition (reduction in the number of eggs laid on the plant) and predation, leading to increased larval mortality. The probability of successful predation was strongly dependent on larval size. If temporarily low ant-patrolling activity allows larvae to grow beyond a critical size, their mechanical (thick integument) or chemical (plant-derived compounds in a fecal shield) defences become more effective against ants. Secondary metabolites derived from the host plant thus appear to be important for the anti-predator mechanisms of this beetle, being necessary for its survival and reproduction on a host plant that actively recruits ants as a biotic defence against herbivores.

  3. Strategy and system of fire protection at Guangdong Daya Bay Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zhou Weihong

    1999-12-01

    The fire protection is an important safety issue of nuclear power utilities. The author depicts the strategy and management system of fire protection implemented successfully at Guangdong Daya Bay Nuclear Power Plant of China

  4. Studies on tritium incorporation into wheat plants after short-term exposure to atmospheric tritium

    International Nuclear Information System (INIS)

    Diabate, S.; Strack, S.; Raskob, W.

    1996-01-01

    The paper summarizes the results of a series of laboratory experiments to study the uptake, loss, conversion and translocation of tritium in wheat plants following a short-term exposure to atmospheric tritiated water vapour (HTO) under laboratory conditions. The experiments were accompanied by the development of a Plant-OBT-Model to calculate the tritium behaviour in wheat. Exposures of potted plants were carried out between anthesis and maturity, under day conditions at two different light intensities (900 μmol m -2 s -1 and 120 μmol m -2 s -1 photosynthetic active radiation) and under night conditions. In leaves, the tritium uptake into tissue water tritium (TWT) was about four times lower under night conditions than day conditions. Organically bound tritium (OBT) was generated in leaves, stems and ears under day as well as under night conditions. The initial relative OBT concentrations in leaves observed under night conditions were about 50% of those under day conditions. OBT was translocated into the grain in dependence on the growth rate of the grain. Due to incorporation of new organic matter with lower OBT concentration into the grain, the specific OBT concentrations decreased slightly until harvest but the total OBT was rather constant. Once translocation to grain has taken place, OBT is lost only slowly. The growth of the plants has been calibrated with the measured growth data of winter wheat and spring wheat. Subsequently, the tritium incorporation was calibrated using the results of the exposure experiments in the same year. The final OBT concentration in the grain can be predicted with sufficient precision. However, the modelling of the OBT formation and turnover processes right after exposure to tritium needs improvement. A comprehensive validation of the model with independent data sets is still necessary. (J.P.N.)

  5. Software V ampersand V methods for digital plant protection system

    International Nuclear Information System (INIS)

    Kim, Hung-Jun; Han, Jai-Bok; Chun, Chong-Son; Kim, Sung; Kim, Kern-Joong.

    1997-01-01

    Careful thought must be given to software design in the development of digital based systems that play a critical role in the successful operation of nuclear power plants. To evaluate the software verification and validation methods as well as to verify its system performance capabilities for the upgrade instrumentation and control system in the Korean future nuclear power plants, the prototype Digital Plant, Protection System (DPPS) based on the Programmable Logic Controller (PLC) has been constructed. The system design description and features are briefly presented, and the software design and software verification and validation methods are focused. 6 refs., 2 figs

  6. Diurnal adjustment in ultraviolet sunscreen protection is widespread among higher plants.

    Science.gov (United States)

    Barnes, Paul W; Flint, Stephan D; Tobler, Mark A; Ryel, Ronald J

    2016-05-01

    The accumulation of ultraviolet (UV)-absorbing compounds (flavonoids and related phenylpropanoids) in the epidermis of higher plants reduces the penetration of solar UV radiation to underlying tissues and is a primary mechanism of acclimation to changing UV conditions resulting from ozone depletion and climate change. Previously we reported that several herbaceous plant species were capable of rapid, diurnal adjustments in epidermal UV transmittance (T UV), but how widespread this phenomenon is among plants has been unknown. In the present study, we tested the generality of this response by screening 37 species of various cultivated and wild plants growing in four locations spanning a gradient of ambient solar UV and climate (Hawaii, Utah, Idaho and Louisiana). Non-destructive measurements of adaxial T UV indicated that statistically significant midday decreases in T UV occurred in 49 % of the species tested, including both herbaceous and woody growth forms, and there was substantial interspecific variation in the magnitude of these changes. In general, plants in Louisiana exhibited larger diurnal changes in T UV than those in the other locations. Moreover, across all taxa, the magnitude of these changes was positively correlated with minimum daily air temperatures but not daily UV irradiances. Results indicate that diurnal changes in UV shielding are widespread among higher plants, vary both within and among species and tend to be greatest in herbaceous plants growing in warm environments. These findings suggest that plant species differ in their UV protection "strategies" though the functional and ecological significance of this variation in UV sunscreen protection remains unclear at present.

  7. Inflammatory Effects of the Plant Protection Product Stifenia (FEN560 on Vertebrates

    Directory of Open Access Journals (Sweden)

    Olivier Lamotte

    2017-04-01

    Full Text Available Plant defense stimulators (PDSs rely on the activation of plant innate immunity in order to protect crops against various pests. These molecules are thought to be a safer alternative to classical plant protection products. Given that innate immune systems share common features in plants and vertebrates, PDS can potentially cross-react with innate immunity of non-target organisms. To test this hypothesis, we studied effects of the commercial PDS Stifenia (FEN560, which is composed of crushed fenugreek seeds. We tested various concentrations of Stifenia (0.03–1 mg mL−1 on human peripheral blood mononuclear cells and checked, 20 h later, cell metabolic activity (MA using XTT assay, cell death by flow cytometry analysis, and IL-1β inflammatory cytokine released in the culture medium using ELISA. Stifenia induced a general decrease of the cell MA, which was concomitant with a dose-dependent release of IL-1β. Our results highlight the activation of human immune cells. The inflammatory effect of Stifenia was partially inhibited by pan-caspase inhibitor. Accordingly, Stifenia induced the release of p20 caspase-1 fragment into the culture medium suggesting the involvement of the NLRP3 inflammasome. Furthermore, we observed that Stifenia can induce cell death. We also tested the effect of Stifenia on Zebrafish larvae. After 24 h of exposure, Stifenia induced a dose-dependent IL-1β and TNFα gene expression. The human-cell-based approach developed in this work revealed a high sensitivity concerning inflammatory properties of a plant protection product. These tests could be routinely used to screen the potential adverse effects of this type of compounds. Finally, our results suggest a potential danger of using extensively certain PDS for crop protection.

  8. Coil protection for a utility scale superconducting magnetic energy storage plant

    International Nuclear Information System (INIS)

    Loyd, R.J.; Schoenung, S.M.; Rogers, J.D.; Hassenzahl, W.V.; Purcell, J.R.

    1986-01-01

    Superconducting Magnetic Energy Storage (SMES) is proposed for electric utility load leveling. Attractive costs, high diurnal energy efficiency (≥ 92%), and rapid response are advantages relative to other energy storage technologies. Recent industry-led efforts have produced a conceptual design for a 5000 MWh/1000 MW energy storage plant which is technically feasible at commercially attractive estimated costs. The SMES plant design includes a protection system which prevents damage to the magnetic coil if events require a rapid discharge of stored energy. This paper describes the design and operation of the coil protection system, which is primarily passive and uses the thermal capacity of the coil itself to absorb the stored electromagnetic energy

  9. Advanced digital PWR plant protection system based on optimal estimation theory

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1981-04-01

    An advanced plant protection system for the Loss-of-Fluid Test (LOFT) reactor plant is described and evaluated. The system, based on a Kalman filter estimator, is capable of providing on-line estimates of such critical variables as fuel and cladding temperature, departure from nucleate boiling ratio, and maximum linear heat generation rate. The Kalman filter equations are presented, as is a description of the LOFT plant dynamic model inherent in the filter. Simulation results demonstrate the performance of the advanced system

  10. Stabilization of heavy metals in fired clay brick incorporated with wastewater treatment plant sludge: Leaching analysis

    Science.gov (United States)

    Kadir, A. A.; Hassan, M. I. H.; Salim, N. S. A.; Sarani, N. A.; Ahmad, S.; Rahmat, N. A. I.

    2018-04-01

    Wastewater treatment sludge or known as sewage sludge is regarded as the residue and produced by the sedimentation of the suspended solid during treatment at the wastewater treatment plant. As such, this sludge was gained from the separation process of the liquids and solids. This sludge wastes has becomes national issues in recent years due to the increasing amount caused by population and industrialization growth in Malaysia. This research was conducted to fully utilize the sludge that rich in dangerous heavy metals and at the same time act as low cost alternative materials in brick manufacturing. The investigation includes determination of heavy metal concentration and chemical composition of the sludge, physical and mechanical properties. Wastewater treatment sludge samples were collected from wastewater treatment plant located in Johor, Malaysia. X-Ray Fluorescence was conducted to determine the heavy metals concentration of wastewater treatment sludge. Different percentage of sludges which are 0%, 1%, 5%, 10%, and 20%, has been incorporated into fired clay brick. The leachability of heavy metals in fired clay brick that incorporated with sludge were determined by using Toxicity Characteristic Leaching Procedure (TCLP) and Synthetic Precipitation Leachability Procedure (SPLP) that has been analyzed by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The results show a possibility to stabilize the heavy metals in fired clay brick incorporated with wastewater treatment sludge. 20% of the sludge incorporated into the brick is the most suitable for building materials as it leached less heavy metals concentration and complying with USEPA standard.

  11. Design concepts to enhance nuclear power plant protection

    International Nuclear Information System (INIS)

    Ericson, D.M. Jr.; Varnado, G.B.

    1980-01-01

    Using a modern design for a nuclear power plant as a point of departure, this study examines the enhancement of protection which may be achieved by changes to the design. These changes include concepts such as complete physical separation of redundant trains of safety equipment, hardened enclosures for water storage tanks, and hardened shutdown heat removal systems. The degree of enhancement (value) is examined in terms such as the potential reduction in the number of vital areas and the increase in probability of adversary sequence interruption. The impacts considered include constraints imposed upon operations and maintenance personnel and increased capital and operating costs. The study concludes that structural design changes alone do not provide significant increases in protection

  12. Leachability of fired clay brick incorporating with sewage sludge waste

    Science.gov (United States)

    Kadir, Aeslina Abdul; Salim, Nurul Salhana Abdul; Sarani, Noor Amira; Rahmat, Nur Aqma Izurin; Abdullah, Mohd Mustafa Al Bakri

    2017-09-01

    Sewage sludge is sewerage from wastewater treatment plants that generates millions tons of sludge ever year. Regarding this activity, it causes lack management of waste which is harmful to the surrounding conditions. Therefore, this study is focuses on the incorporation of sewage sludge waste into fired clay brick to provide an option of disposal method, producing adequate quality of brick as well as limiting the heavy metal leachability to the environment. Sewage sludge brick (SSB) mixtures were incorporated with 0%, 1%, 5%, 10%, 20% and 30% of sewage sludge waste (SSW). Heavy metals of crushed SSB were determined by using Toxicity Characteristic Leaching Procedure (TCLP) according to Method 1311 of United State Environment Protection Agency (USEPA) standard. From the results obtained, up to 20% of SSW could be incorporated into fired clay brick and comply with the USEPA standard. Therefore, this study revealed that by incorporating SSW into fired clay brick it could be an alternative method to dispose the SSW and also could act as a replacement material for brick manufacturing with appropriate mix and design.

  13. Earthquake protection of nuclear power plant equipment

    Energy Technology Data Exchange (ETDEWEB)

    Nawrotzki, Peter [GERB Vibration Control Systems, Berlin (Germany)

    2010-05-15

    Power plant machinery can be dynamically decoupled from the substructure by the effective use of helical steel springs and viscous dampers. Turbine foundations, boiler feed pumps and other machine foundations benefit from this type of elastic support systems to mitigate the transmission of operational vibration. The application of these devices may also be used to protect against earthquakes and other catastrophic events, i.e. airplane crash, of particular importance in nuclear facilities. This article illustrates basic principles of elastic support systems and applications on power plant buildings in medium and high seismic areas. Spring-damper combinations with special stiffness properties are used to reduce seismic acceleration levels of turbine components and other safety or non-safety related structures. For turbine buildings, the integration of the turbine substructure into the machine building can further reduce stress levels in all structural members. (orig.)

  14. Earthquake protection of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Nawrotzki, Peter

    2010-01-01

    Power plant machinery can be dynamically decoupled from the substructure by the effective use of helical steel springs and viscous dampers. Turbine foundations, boiler feed pumps and other machine foundations benefit from this type of elastic support systems to mitigate the transmission of operational vibration. The application of these devices may also be used to protect against earthquakes and other catastrophic events, i.e. airplane crash, of particular importance in nuclear facilities. This article illustrates basic principles of elastic support systems and applications on power plant buildings in medium and high seismic areas. Spring-damper combinations with special stiffness properties are used to reduce seismic acceleration levels of turbine components and other safety or non-safety related structures. For turbine buildings, the integration of the turbine substructure into the machine building can further reduce stress levels in all structural members. (orig.)

  15. Uptake and distribution of combined nitrogen and its incorporation into seeds of nodulated soybean plants as revealed by 15N studies

    International Nuclear Information System (INIS)

    Rabie, R.K.; Arima, Yasuhiro; Kumazawa, Kikuo

    1980-01-01

    Pot experiments were carried out with soybean plants grown with N-free solution, then supplied with NO 3 - or NH 4 + before 15 N administration, in order to study the uptake, distribution and redistribution of absorbed nitrogen. To determine the utilization and incorporation of combined nitrogen to the yield of seeds, as influenced by the form of N and application time, another series of experiments was carried out, in which the plants were grown with N-free solution, then 15 N was fed as 15 NO 3 - or 15 NH 4 + at pod setting stage (PS) or initial pod filling stage (IPF). By comparing the nitrate-treated plants (Nt plants) with the ammonia-treated ones (Am plants), and the treatment at PS with that at IPF, the following results were obtained. Nt plants accumulated larger amount of dry matters in respective plant parts than Am plants, particularly in the pods, and it was proved that the pods were the active sinks for newly metabolized nitrate. Both 15 N abundance and 15 N incorporation in the whole plants were much higher in Nt plants, and those in respective plant parts except nodules were also higher in Nt plants. Large part of the 15 N in roots was redistributed to the top parts in Nt plants, while large part of the absorbed N was distributed to the nodules in Am plants. Some more results are reported. (Kako, I.)

  16. Periodic inspections of lightning protection systems in intermediate storage facilities of nuclear technological plants

    International Nuclear Information System (INIS)

    Witzel, Andre; Schulz, Olav

    2013-01-01

    Especially for nuclear technological plants, periodic inspections of lightning protection systems are of great importance. This article shows the sequence of maintenance programs using the examples of the intermediate storage facilities of the nuclear technological plants Grohnde and Unterweser as well as the central intermediate storage facility in Gorleben and gives a description of the extensive measures of inspecting the external and internal lightning protection and the global earth termination system.

  17. Incorporation of 14CO2 by illuminated intact leaves of bean (PHASEOLUS VULGARIS) plants

    International Nuclear Information System (INIS)

    Andrade, A.G. de

    1980-01-01

    Bean plants were grown in hydroponic nutrient solution, maintained in controlled environment. Measurements of the photosynthetic activity using the method of 14 CO 2 incorporation in intact leaves with portable equipment were made on the central leaflet of the first trifoliate leaf except when the effect of leaf age was studied in which case all central leaflets of the same branch were used. The data obtained indicated differences in the photosynthetic efficiency of bean (Phaseolus vulgaris) cultivars. Relative differences in RuDP carboxylase activity in the crude extracts of leaves, leaf area and leaf chlorophyll content were also observed. Rates of 14 CO 2 incorporation at saturating light varied from 14.94 to 22.96 mg CO 2 .dm -2 .h and the 6 studied cultivars could be divided into two classes: Classe 1 (above 20 mg CO 2 .dm -2 .h): Pirata-1, Rosinha G-2, and Pintadinho Precoce; Classe 2 (below 20 mg CO 2 .dm - 2 .h): Carioca, Rosinha Precoce and Pintado. Plants of the same cultivar showed a relatively high variability and a strong dependence in relation to environmental conditions. Differences among cultivars in relation to RuDP carboxylase activity, leaf area and leaf age were correlated to photosynthetic rate. (Author) [pt

  18. Review of the radiation protection calculations for the encapsulation plant

    International Nuclear Information System (INIS)

    Ranta-aho, A.

    2008-09-01

    The radiation protection calculations of the encapsulation plant have been carried out with the MCNP5 Monte Carlo code. The focus of the study has been in the parts of the encapsulation plant where the spent fuel is handled after discharge from the transportation casks i.e. the fuel handling cell, the fuel drying station, the canister transfer corridor, the welding chamber, the weld inspection room, the canister buffer storage and the canister lift. The protection against radiation hazard has been mainly designed with thick concrete walls. Additionally, the entrances to the rooms with shielding requirements have been equipped with mazes. The present design excludes doors with shielding properties. The aim of this work was to verify and evaluate the necessary wall thicknesses and the functioning of the mazes in the current design. The calculations verified that for the most parts of the facility, the currently designed walls thicknesses provide adequate protection against radiation from the different spent fuel assembly configurations. Some corrective actions however seem necessary in order to stay clearly below desired radiation limits. For the most parts the functioning of the mazes was inadequate. In some of the cases a different design of the maze will be sufficient action but in some cases the radiation protection can only be secured by heavy doors for practical reasons. (orig.)

  19. Laboratory evaluation of four medicinal plants as protectants against ...

    African Journals Online (AJOL)

    The petroleum ether extract of four medicinal plants; Aristolochia ringens (Vahl), Allium sativum (L), Ficus exasperata (L) and Garcinia kola (H), were evaluated as grain protectant against the maize weevil, Sitophilus zeamais (Mots) in the laboratory at 0.5, 1.0 and 1.5% (w/v) concentrations. Parameters assessed were adult ...

  20. Incorporation of Socio-Economic Features' Ranking in Multicriteria Analysis Based on Ecosystem Services for Marine Protected Area Planning.

    Directory of Open Access Journals (Sweden)

    Michelle E Portman

    Full Text Available Developed decades ago for spatial choice problems related to zoning in the urban planning field, multicriteria analysis (MCA has more recently been applied to environmental conflicts and presented in several documented cases for the creation of protected area management plans. Its application is considered here for the development of zoning as part of a proposed marine protected area management plan. The case study incorporates specially-explicit conservation features while considering stakeholder preferences, expert opinion and characteristics of data quality. It involves the weighting of criteria using a modified analytical hierarchy process. Experts ranked physical attributes which include socio-economically valued physical features. The parameters used for the ranking of (physical attributes important for socio-economic reasons are derived from the field of ecosystem services assessment. Inclusion of these feature values results in protection that emphasizes those areas closest to shore, most likely because of accessibility and familiarity parameters and because of data biases. Therefore, other spatial conservation prioritization methods should be considered to supplement the MCA and efforts should be made to improve data about ecosystem service values farther from shore. Otherwise, the MCA method allows incorporation of expert and stakeholder preferences and ecosystem services values while maintaining the advantages of simplicity and clarity.

  1. Improvement of fire protection measures for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Improvements of fire protection measures for nuclear power plants were performed as following items: Development of fire hazard analysis method. Application of developed Fire Dynamic Tool to actual plants (FDT{sup S}), With regard to fire tests for the fire data acquisition, cable fire test and High Energy Arcing Faults (HEAF) fire test were performed. Implementation of fire hazard analysis code and simulation were performed as following items: Fire analysis codes FDS, SYLVIA, and CFAST were implemented in order to analyze the fire progression phenomena. Trial simulation of HEAF accident of Onagawa NPP in Tohoku earthquake. (author)

  2. Improvement of fire protection measures for nuclear power plants

    International Nuclear Information System (INIS)

    2012-01-01

    Improvements of fire protection measures for nuclear power plants were performed as following items: Development of fire hazard analysis method. Application of developed Fire Dynamic tool to actual plants, With regard to fire tests for the fire data acquisition, cable fire test and oil fire test were performed. Implementation of fire hazard analysis code and simulation were performed as following items: Fire analysis codes FDS, SYLVIA, CFAST were implemented in order to analyze the fire progression phenomena, Trial simulation of fire hazard as Metal-Clad Switch Gear Fire of ONAGAWA NPP in Tohoku earthquake (HEAF accident). (author)

  3. The potential impact of invasive woody oil plants on protected areas in China under future climate conditions.

    Science.gov (United States)

    Dai, Guanghui; Yang, Jun; Lu, Siran; Huang, Conghong; Jin, Jing; Jiang, Peng; Yan, Pengbo

    2018-01-18

    Biodiesel produced from woody oil plants is considered a green substitute for fossil fuels. However, a potential negative impact of growing woody oil plants on a large scale is the introduction of highly invasive species into susceptible regions. In this study, we examined the potential invasion risk of woody oil plants in China's protected areas under future climate conditions. We simulated the current and future potential distributions of three invasive woody oil plants, Jatropha curcas, Ricinus communis, and Aleurites moluccana, under two climate change scenarios (RCP2.6 and RCP8.5) up to 2050 using species distribution models. Protected areas in China that will become susceptible to these species were then identified using a spatial overlay analysis. Our results showed that by 2050, 26 and 41 protected areas would be threatened by these invasive woody oil plants under scenarios RCP2.6 and RCP8.5, respectively. A total of 10 unique forest ecosystems and 17 rare plant species could be potentially affected. We recommend that the invasive potential of woody oil plants be fully accounted for when developing forest-based biodiesel, especially around protected areas.

  4. Interactions among predators and plant specificity protect herbivores from top predators.

    Science.gov (United States)

    Bosc, Christopher; Pauw, Anton; Roets, Francois; Hui, Cang

    2018-05-04

    The worldwide loss of top predators from natural and agricultural systems has heightened the need to understand how important they are in controlling herbivore abundance. The effect of top predators on herbivore species is likely to depend on 1) the importance of the consumption of intermediate predators by top predators (intra-guild predation; IGP), but also on 2) plant specificity by herbivores, because specialists may defend themselves better (enemy-free space; EFS). Insectivorous birds, as top predators, are generally known to effectively control herbivorous insects, despite also consuming intermediate predators such as spiders, but how this effect varies among herbivore species in relation to the cascading effects of IGP and EFS is not known. To explore this, we excluded birds from natural fynbos vegetation in South Africa using large netted cages and recorded changes in abundance relative to control plots for 199 plant-dwelling intermediate predator and 341 herbivore morpho-species that varied in their estimated plant specificity. We found a strong negative effect of birds on the total abundance of all intermediate predators, with especially clear effects on spiders (strong IGP). In contrast with previous studies, which document a negative effect of birds on herbivores, we found an overall neutral effect of birds on herbivore abundance, but the effect varied among species: some species were negatively affected by birds, suggesting that they were mainly consumed by birds, whereas others, likely released from spiders by IGP, were positively affected. Some species were also effectively neutrally affected by birds. These tended to be more specialized to plants compared to the other species, which may imply that some plant specialists benefited from protection provided by EFS from both birds and spiders. These results suggest that the response of herbivore species to top predators may depend on cascading effects of interactions among predators and on their degree

  5. Advanced digital instrumentation and control system for nuclear power plant protection

    International Nuclear Information System (INIS)

    Sabino, D.

    1997-01-01

    The Diverse Protection System (DPS) is described. The DPS is a state-of-the-art digital protection system developed as a back-up to the primary reactor protection system at the Temelin nuclear power plant, featuring a compact hardware design based on VMEbus technology. This technology allows for ease in adding or modifying the number and type of input modules and processors. The DPS software is written in a high level language suitable for safety critical applications. The software is both modular and configurable allowing for potential future modifications and software reuse

  6. Health protection and industrial safety. Nuclear power plants

    International Nuclear Information System (INIS)

    1987-03-01

    The standard applies to components of the primary circuit including its auxiliary facilities, and of the secondary circuit of nuclear power plants with pressurized water reactors; to lifting gear and load take-ups for the transport of nuclear fuel and primary circuit components; to elevators within the containment, electrical installations, and piping and valves of radiation protection monitoring equipment. Part 1 defines the terms and specifies engineered safety requirements

  7. Novel roles for genetically modified plants in environmental protection

    Czech Academy of Sciences Publication Activity Database

    Macek, Tomáš; Kotrba, Pavel; Svatoš, Aleš; Nováková, Martina; Demnerová, K.; Macková, Martina

    2008-01-01

    Roč. 26, č. 3 (2008), s. 146-152 ISSN 0167-7799 R&D Projects: GA AV ČR IAA4055204; GA MŠk 1M06030 Institutional research plan: CEZ:AV0Z40550506 Keywords : transgenic plant * environmental protection * insect pheromone * phytoremediation Subject RIV: EI - Biotechnology ; Bionics Impact factor: 6.624, year: 2008

  8. THE USE OF PLANTS TO PROTECT PLANTS AND FOOD AGAINST FUNGAL PATHOGENS: A REVIEW.

    Science.gov (United States)

    Shuping, D S S; Eloff, J N

    2017-01-01

    Plant fungal pathogens play a crucial role in the profitability, quality and quantity of plant production. These phytopathogens are persistent in avoiding plant defences causing diseases and quality losses around the world that amount to billions of US dollars annually. To control the scourge of plant fungal diseases, farmers have used fungicides to manage the damage of plant pathogenic fungi. Drawbacks such as development of resistance and environmental toxicity associated with these chemicals have motivated researchers and cultivators to investigate other possibilities. Several databases were accessed to determine work done on protecting plants against plant fungal pathogens with plant extracts using search terms "plant fungal pathogen", "plant extracts" and "phytopathogens". Proposals are made on the best extractants and bioassay techniques to be used. In addition to chemical fungicides, biological agents have been used to deal with plant fungal diseases. There are many examples where plant extracts or plant derived compounds have been used as commercial deterrents of fungi on a large scale in agricultural and horticultural setups. One advantage of this approach is that plant extracts usually contain more than one antifungal compound. Consequently the development of resistance of pathogens may be lower if the different compounds affect a different metabolic process. Plants cultivated using plants extracts may also be marketed as organically produced. Many papers have been published on effective antimicrobial compounds present in plant extracts focusing on applications in human health. More research is required to develop suitable, sustainable, effective, cheaper botanical products that can be used to help overcome the scourge of plant fungal diseases. Scientists who have worked only on using plants to control human and animal fungal pathogens should consider the advantages of focusing on plant fungal pathogens. This approach could not only potentially increase

  9. [Storage of plant protection products in farms: minimum safety requirements].

    Science.gov (United States)

    Dutto, Moreno; Alfonzo, Santo; Rubbiani, Maristella

    2012-01-01

    Failure to comply with requirements for proper storage and use of pesticides in farms can be extremely hazardous and the risk of accidents involving farm workers, other persons and even animals is high. There are still wide differences in the interpretation of the concept of "securing or making safe", by workers in this sector. One of the critical points detected, particularly in the fruit sector, is the establishment of an adequate storage site for plant protection products. The definition of "safe storage of pesticides" is still unclear despite the recent enactment of Legislative Decree 81/2008 regulating health and work safety in Italy. In addition, there are no national guidelines setting clear minimum criteria for storage of plant protection products in farms. The authors, on the basis of their professional experience and through analysis of recent legislation, establish certain minimum safety standards for storage of pesticides in farms.

  10. Polyamine Spermine Protects Young Pea Plants Against Ultraviolet-C Radiation

    International Nuclear Information System (INIS)

    Todorovska, D.; Katerova, Z.; Shopova, E.; Nikolova, A.; Georgieva, N.; Sergiev, I.

    2013-01-01

    The effects of ultraviolet-C - UV-C irradiation and polyamine spermine on the content of some stress marker and non-enzymatic antioxidants in leaves of young pea plants were investigated. UV-C irradiation led to a decrease in pea fresh weight, the content of leaf pigments and free proline, accompanied with an increase in malondialdehyde. The initial augmentation in the free thiol levels was transient in UV-C treated plants and finally a substantial decrease was found. Spermine led to a significant augmentation of free thiols and proline content along with a decline in total phenols, but these alterations diminished during the experimental period. Based on comparative analyses of the results obtained for plants treated with UV-C and polyamine, it could be concluded that preliminary application of spermine protects pea plants against irradiation, by maintaining normal plant growth, stabilizing cell membranes and activating non-enzymatic antioxidants

  11. Trends in radiation protection: possible effects on fusion power plant design

    International Nuclear Information System (INIS)

    Eurajoki, Tapani; Frias, Manuel Pascual; Orlandi, Sergio

    2003-01-01

    Since the design of fusion power plants involves long-term issues, ranging over several decades, it is useful to try to foresee under what kind of regulations the first fusion plants are to be operated. Application of present radiological regulations and practice to a fusion power plant concept is considered. The current design phase of fusion power plants motivates the top-down dose assessment, but it is crucial to aim at bottom-up assessments to ensure radiation doses as low as reasonably achievable. Since several issues, relating both to our knowledge on radiation as well as to the practice of radiation protection, may change in the future, it is necessary to continuously follow the development in the further design of fusion power plants

  12. Habitat models to assist plant protection efforts in Shenandoah National Park, Virginia, USA

    Science.gov (United States)

    Van Manen, F.T.; Young, J.A.; Thatcher, C.A.; Cass, W.B.; Ulrey, C.

    2005-01-01

    During 2002, the National Park Service initiated a demonstration project to develop science-based law enforcement strategies for the protection of at-risk natural resources, including American ginseng (Panax quinquefolius L.), bloodroot (Sanguinaria canadensis L.), and black cohosh (Cimicifuga racemosa (L.) Nutt. [syn. Actaea racemosa L.]). Harvest pressure on these species is increasing because of the growing herbal remedy market. We developed habitat models for Shenandoah National Park and the northern portion of the Blue Ridge Parkway to determine the distribution of favorable habitats of these three plant species and to demonstrate the use of that information to support plant protection activities. We compiled locations for the three plant species to delineate favorable habitats with a geographic information system (GIS). We mapped potential habitat quality for each species by calculating a multivariate statistic, Mahalanobis distance, based on GIS layers that characterized the topography, land cover, and geology of the plant locations (10-m resolution). We tested model performance with an independent dataset of plant locations, which indicated a significant relationship between Mahalanobis distance values and species occurrence. We also generated null models by examining the distribution of the Mahalanobis distance values had plants been distributed randomly. For all species, the habitat models performed markedly better than their respective null models. We used our models to direct field searches to the most favorable habitats, resulting in a sizeable number of new plant locations (82 ginseng, 73 bloodroot, and 139 black cohosh locations). The odds of finding new plant locations based on the habitat models were 4.5 (black cohosh) to 12.3 (American ginseng) times greater than random searches; thus, the habitat models can be used to improve the efficiency of plant protection efforts, (e.g., marking of plants, law enforcement activities). The field searches also

  13. An Improved Setpoint Determination Methodology for the Plant Protection System Considering Beyond Design Basis Events

    International Nuclear Information System (INIS)

    Lee, C.J.; Baik, K.I.; Baek, S.M.; Park, K.-M.; Lee, S.J.

    2013-06-01

    According to the nuclear regulations and industry standards, the trip setpoint and allowable value for the plant protection system have been determined by considering design basis events. In order to improve the safety of a nuclear power plant, an attempt has been made to develop an improved setpoint determination methodology for the plant protection system trip parameter considering not only a design basis event but also a beyond design basis event. The results of a quantitative evaluation performed for the Advanced Power Reactor 1400 nuclear power plant in Korea are presented herein. The results confirmed that the proposed methodology is able to improve the nuclear power plant's safety by determining more reasonable setpoints that can cover beyond design basis events. (authors)

  14. 40 CFR 59.412 - Incorporations by reference.

    Science.gov (United States)

    2010-07-01

    ... Test Method for Chemical Resistance of Coatings Used in Light-Water Nuclear Power Plants, incorporation by reference approved for § 59.401, Nuclear coating. (5) ASTM Method D 4082-89, Standard Test Method for Effects of Gamma Radiation on Coatings for Use in Light-Water Nuclear Power Plants, incorporation...

  15. A development of digital plant protection system architecture

    International Nuclear Information System (INIS)

    Seong, S. H.; Park, H. Y.; Kim, D. H.; Seo, Y. S.; Gu, I. S.

    2000-01-01

    The digital plant protection system (DPPS) which have a large number of advantages compared to current analog protection system has been developed in various field. The major disadvantages of digital system are, however, vulnerable to faults of processor and software. To overcome the disadvantages, the concept of segment and partition in a channel has been developed. Each segment in a channel is divided from sensor to reactor trip and engineered safety features, which is based on the functional diversity of input signals against the various plant transient phenomena. Each partition allocates the function module to an independent processing module in order to process and isolate the faults of each module of a segment. A communication system based on the deterministic protocol with the predictable and hard real-time characteristics has been developed in order to link the various modules within a segment. The self-diagnostics including online test and periodic test procedures are developed in order to increase the safety, reliability and availability of DPPS. The developed DPPS uses the off-the-shelf DSP (digital signal processor) and adopts VME bus architecture, which have sufficient operation experience in the industry. The verification and validation and quality assurance of software has been developed and the architecture and protocol of deterministic communication system has been researched

  16. Evaluation of Applicability for the Core Protection Method with 4-Channel CEA Positions to OPR-1000 Plants

    International Nuclear Information System (INIS)

    Koo, B. S.; Cho, J. Y.; Song, J. S.

    2008-05-01

    To increase the applicability of research results established during the process of integral reactor development program, a new core protection method with 4-channel CEA positions was applied to the domestic commercial plants and its feasibility was evaluated. To achieve above object, state-of-the-art related to core protection system was analyzed as followings: - Unusual CPC operating experience in Korea - Evaluate the proposals of CPC improvement suggested by CPC Task Force Team - Review the conventional CPC used in Yonggwang and Ulchin plants - Review the Common-Q CPC to be implemented in Shin-Kori Units 1 and 2 - Evaluate the SENTINEL core protection system in US and COPS core protection system in Germany - Examine the applied patents in Korea, US and Japan - Analyze the copyright for computer programs used in core protection system design and license agreement for PWR technology between Westinghouse and Korea. In addition, study for the formation of system, design requirement, algorithm improvement and enhancement of operator interface was performed to apply the newly suggested core protection method to the commercial plants. By adopting this method, it is expected that unnecessary channel of reactor trips will be decreased considerably. Although change of system including CEA must be set forth as a prerequisite to apply this method to the domestic commercial plants as well as scheduled plants, this study suggests the strategy and direction for the development of core protection system in domestic. This study, moreover, will provide the valuable information as a basic data in establishing the detailed development plan for the advanced core protection system in the future

  17. Greater Focus Needed on Alien Plant Impacts in Protected Areas

    Czech Academy of Sciences Publication Activity Database

    Hulme, P. E.; Pyšek, Petr; Pergl, Jan; Jarošík, Vojtěch; Schaffner, U.; Vila, M.

    2014-01-01

    Roč. 7, č. 5 (2014), s. 459-466 ISSN 1755-263X R&D Projects: GA ČR(CZ) GAP504/11/1028 Institutional support: RVO:67985939 Keywords : plant invasions * impact * protected areas Subject RIV: EF - Botanics Impact factor: 7.241, year: 2014

  18. Burst protected nuclear reactor plant with PWR

    International Nuclear Information System (INIS)

    Harand, E.; Michel, E.

    1978-01-01

    In the PWR, several integrated components from the steam raising unit and the main coolant pump are grouped around the reactor pressure vessel in a multiloop circuit and in a vertical arrangement. For safety reasons all primary circuit components and pipelines are situated in burst protection covers. To reduce the area of the plant straight tube steam raising units with forced circulation are used as steam raising units. The boiler pumps are connected to the vertical tubes and to the pressure vessel via double pipelines made as twin chamber pipes. (DG) [de

  19. Quantitative evaluation of physical protection system in nuclear power plant

    International Nuclear Information System (INIS)

    Sun Yahua; Li Bin; Li Shiju

    2009-01-01

    Based on the prompt detection analysis, this paper introduced one analysis model of intrusion path in nuclear power plant by means of morphology analysis and developed the evaluation software for path model analysis of physical protection system. Quantitative analysis on three elements (detection, delay, and response) of physical protection system was presented with an imaginary intrusion event example in Mac Arthur nuclear center. The results indicated that the path prompt detection analysis worked effectively to find the weak point of the physical protection system in NPP, and meantime we can also get the high cost-effectiveness improved measures. It is an effective approach to evaluate the overall performance of the system. (authors)

  20. Fish protection at steam-electric power plants: alternative screening devices

    International Nuclear Information System (INIS)

    Cannon, J.B.

    1978-01-01

    Since the enactment of the Federal Water Pollution Control Act Amendments of 1972, very few innovations have surfaced that advance the state of intake technology for fish protection at steam-electric power plants. After careful examination of basic hydrology, hydraulics, and ecology of the source water body is completed and after a suitable location for the intake is established, the design process reduces to the development of proper screening techniques and to the provision of a means of preventing resident and migratory species from entering the intake structure. As a result of this design process, three basic fish protection concepts have evolved: fish deterrence, fish collection and removal, and fish diversion. Intake screening devices that protect fish are discussed

  1. Radiation protection in connection with the decommissioning of nuclear plants

    International Nuclear Information System (INIS)

    1997-04-01

    This document presents the SSI preliminary views and position concerning the decommissioning of nuclear plants. To prevent the exposure of the decommissioning personnel and the general public to unacceptable levels of radiation and to protect the environment and future generations, it is SSI's task to formulate and issue the necessary terms and regulations with which the reactor licensees must comply during the decommissioning work. The views and principles presented here are the basis of SSI's continued work on guidelines and regulations for the decommissioning of nuclear plants

  2. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  3. Electric protections based in microprocessors in power plants; Protecciones electricas basadas en microprocesadores en centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Libreros, Domitilo; Castanon Jimenez, Jose Ismael [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    This article is centered around the substitution of the conventional electric protections of a power plant in connection type unit for protections based in microprocessors. A general model of conventional protection of a power plant is described and the number of analogic and digital signals that intervene in that model are quantified. A model is setup for power plant protection with microprocessors, analyzing each one of the modules that would form it. Finally, the algorithms to carry on such protection are presented. [Espanol] Este articulo se centra en torno a la sustitucion de las protecciones electricas convencionales de una central generadora en conexion tipo unidad por protecciones basadas en microprocesadores. Se describe el modelo general de proteccion convencional de una central generadora y se cuantifica el numero de senales analogicas y digitales que interviene en dicho modelo. Se propone un modelo para proteccion de centrales generadoras mediante microprocesadores, analizandose cada uno de los modulos que lo conformarian. Finalmente, se presentan los algoritmos para realizar dicha proteccion.

  4. 76 FR 20368 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Science.gov (United States)

    2011-04-12

    ... Leader, Sacramento National Wildlife Refuge Complex, U.S. Fish and Wildlife Service, 752 County Road 99W... old and eroding, it plays a key role in protecting the PCGID-PID pumping plant. As the bank erodes... interdisciplinary team began studies to examine measures to protect the PCGID-PID pumping plant and fish screen...

  5. Nuclear power plant component protection

    International Nuclear Information System (INIS)

    Michel, E.; Ruf, R.; Dorner, H.

    1976-01-01

    Described is a nuclear power plant installation which includes a concrete biological shield forming a pit in which a reactor pressure vessel is positioned. A steam generator on the outside of the shield is connected with the pressure vessel via coolant pipe lines which extend through the shield, the coolant circulation being provided by a coolant pump which is also on the outside of the shield. To protect these components on the outside of the shield and which are of mainly or substantially cylindrical shape, semicylindrical concrete segments are interfitted around them to form complete outer cylinders which are retained against outward separation radially from the components, by rings of high tensile steel which may be interspaced so closely that they provide, in effect, an outer steel cylinder. The invention is particularly applicable to pressurized-water coolant reactor installations

  6. Seaweed Polysaccharides and Derived Oligosaccharides Stimulate Defense Responses and Protection Against Pathogens in Plants

    Directory of Open Access Journals (Sweden)

    Alejandra Moenne

    2011-11-01

    Full Text Available Plants interact with the environment by sensing “non-self” molecules called elicitors derived from pathogens or other sources. These molecules bind to specific receptors located in the plasma membrane and trigger defense responses leading to protection against pathogens. In particular, it has been shown that cell wall and storage polysaccharides from green, brown and red seaweeds (marine macroalgae corresponding to ulvans, alginates, fucans, laminarin and carrageenans can trigger defense responses in plants enhancing protection against pathogens. In addition, oligosaccharides obtained by depolymerization of seaweed polysaccharides also induce protection against viral, fungal and bacterial infections in plants. In particular, most seaweed polysaccharides and derived oligosaccharides trigger an initial oxidative burst at local level and the activation of salicylic (SA, jasmonic acid (JA and/or ethylene signaling pathways at systemic level. The activation of these signaling pathways leads to an increased expression of genes encoding: (i Pathogenesis-Related (PR proteins with antifungal and antibacterial activities; (ii defense enzymes such as pheylalanine ammonia lyase (PAL and lipoxygenase (LOX which determine accumulation of phenylpropanoid compounds (PPCs and oxylipins with antiviral, antifugal and antibacterial activities and iii enzymes involved in synthesis of terpenes, terpenoids and/or alkaloids having antimicrobial activities. Thus, seaweed polysaccharides and their derived oligosaccharides induced the accumulation of proteins and compounds with antimicrobial activities that determine, at least in part, the enhanced protection against pathogens in plants.

  7. Radiological protection in nuclear power plants

    International Nuclear Information System (INIS)

    Zorrilla R, S.

    2008-12-01

    This presentation sharing experiences which correspond to the nuclear power plant of Laguna Verde. This nuclear power plant is located at level 2 of four possible, in the classification performance of the World Association of Nuclear Operators (WANO), which means the mexican nuclear power plant is classified in terms of its performance indicators and above the average achieved by their counterparts americans and canadians. In the national context, the nuclear power plant of Laguna Verde has also been honored with several awards such as the National Quality Award, the Clean Industry Certificate, the distinction of Environmental Excellence and others of similar importance. For the standards of WANO, the basic idea is that there are shortcomings in one of nuclear power plant concern to all partners. The indicators used for the classification will always go beyond more compliance with regulations, which are assumed, and rather assume come or a path to excellence. Among the most important indicators are: the collective dose, the percentage of areas declared as contaminated, the number, type and tendency of contamination personal cases, the number of dosimetry alarms, the number of unplanned exposures, loss control of high radiation areas and the release of contaminated material outside the restricted areas. Furthermore, as already indicated, nuclear power plants are of special care situations, such as, carrying out work in areas with radiation fields of more than 15 mSv h -1 , the movement of spent fuel in the reload floor. The consideration of the minimum total effective dose equivalent as a criterion for prescribing tools that reduce exposures, but may increase the external cases of contaminated casualties, the experience in portals such as workers subject to radiology, where exposure in industrial radiography, and so on. Special mention deserve the conditions generated during fuel reload stops, which causes a massive personnel movement, working simultaneously on

  8. Plant Control Concept for the Sodium Cooled Fast Reactor

    International Nuclear Information System (INIS)

    Kim, Eui Kwang; Kim, S. O.

    2010-12-01

    A power plant is designed for incorporation into a utility's grid system and follows the load demand through the steam generator, intermediate heat exchanger(IHX), from the nuclear core. During the load-following transients, various plant parameters must be controlled to protect the reactor core and other components in the plant. The purpose of this report is to review design considerations to establish SFR plant control and to design plant control concepts. The governing equations and solution procedure of the computer code to calculate plant temperature conditions during the part-load operation was reviewed and 4 types of plant operation concepts were designed, and the results of the calculations were compared

  9. Radiation protection aspects of design for nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    . The IAEA takes seriously the enduring challenge for users and regulators everywhere: that of ensuring a high level of safety in the use of nuclear materials and radiation sources around the world. Their continuing utilization for the benefit of humankind must be managed in a safe manner, and the IAEA safety standards are designed to facilitate the achievement of that goal. This Safety Guide has been prepared as a part of the IAEA programme on safety standards for nuclear power plants. It includes recommendations on how to satisfy the requirements established in the Safety Requirements publication on the Safety of Nuclear Power Plants: Design. It addresses the provisions that should be made in the design of nuclear power plants in order to protect site personnel, the public and the environment against radiological hazards for operational states, decommissioning and accident conditions. The recommendations on radiation protection provided in this Safety Guide are consistent with the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS), which were jointly sponsored by the Food and Agriculture Organization of the United Nations (FAO), the IAEA, the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO). This Safety Guide supersedes Safety Series No. 50-SG-D9, Design Aspects of Radiation Protection for Nuclear Power Plants, published in 1985. Effective radiation protection is a combination of good design, high quality construction and proper operation. Procedures that address the radiation protection aspects of operation are covered in the Safety Guide on Radiation Protection and Radioactive Waste Management in the operation of Nuclear Power Plants

  10. Protection Performance Simulation of Coal Tar-Coated Pipes Buried in a Domestic Nuclear Power Plant Using Cathodic Protection and FEM Method

    Energy Technology Data Exchange (ETDEWEB)

    Chang, H. Y.; Lim, B. T.; Kim, K. S.; Kim, J. W.; Park, H. B. [KEPCO Engineering and Construction Company, Gimcheon (Korea, Republic of); Kim, Y. S.; Kim, K. T. [Andong National University, Andong (Korea, Republic of)

    2017-06-15

    Coal tar-coated pipes buried in a domestic nuclear power plant have operated under the cathodic protection. This work conducted the simulation of the coating performance of these pipes using a FEM method. The pipes, being ductile cast iron have been suffered under considerably high cathodic protection condition beyond the appropriate condition. However, cathodic potential measured at the site revealed non-protected status. Converting from 3D CAD data of the power plant to appropriate type for a FEM simulation was conducted and cathodic potential under the applied voltage and current was calculated using primary and secondary current distribution and physical conditions. FEM simulation for coal tar-coated pipe without defects revealed over-protection condition if the pipes were well-coated. However, the simulation for coal tar-coated pipes with many defects predict that the coated pipes may be severely degraded. Therefore, for high risk pipes, direct examination and repair or renewal of pipes are strongly recommended.

  11. Fire protection requirements of the insurance industry and their impact on nuclear power plant design and construction

    International Nuclear Information System (INIS)

    Deitchman, J.V.; King, W.T. Jr.; Nashman, T.A.

    1976-01-01

    The insurance industry, with its wealth of knowledge and experience in the fire protection area and with preservation of its funds at stake, has always been heavily involved in the fire protection programs of nuclear power plants. Since it was concerned with property preservation in addition to nuclear safety, the insurance industry placed more detailed emphasis on fire protection requirements than did the nuclear regulatory bodies. Since the Browns Ferry fire, however, the insurance industry, the Nuclear Regulatory Commission, the Advisory Committee on Reactor Safeguards and the utilities themselves have re-examined their approaches to fire protection. A more coordinated approach seems to have emerged, which is based largely upon insurance industry specifications and guidelines. The paper briefly summarizes the fire protection requirements of the insurance industry as they apply to nuclear power plants. Some of the ways these requirements affect project planning, plant design, and construction timing are reviewed, as well as some of the more controversial fire protection areas

  12. Radiation safety and protection on the nuclear power plants

    International Nuclear Information System (INIS)

    Nosovskij, A.V.; Bogorad, V.I.; Vasil'chenko, V.N.; Klyuchnikov, A.A.; Litvinskaya, T.V.; Slepchenko, A.Yu.

    2008-01-01

    The main issues of the radiation safety and protection provision on the nuclear power plants are considered in this monograph. The description of the basic sources of the radiation danger on NPPs, the principles, the methods and the means of the safety and radiation monitoring provision are shown. The special attention is paid to the issues of the ionizing radiation regulation

  13. Radiation protection service for a nucleonic control system of continuous casting plant after events of accident

    International Nuclear Information System (INIS)

    Chakrabarti, Santanu; Massand, O.P.

    1998-01-01

    Extensive use of nucleonic control systems like level controllers was observed during radiation protection surveys in industries such as refineries, steel plants etc., located in the eastern region of India. There were two accidents at continuous casting plant in 1995 which affected the nucleonic control system installed in 1992. The authorities contacted Bhabha Atomic Research Centre (BARC) for radiation protection surveys for the involved nucleonic gauges. The present paper describes the radiation protection services rendered by BARC during such accidents. (author)

  14. Improvements done at Heavy Water Plant (Manuguru) to increase the standards of environmental protection

    International Nuclear Information System (INIS)

    Rama Rao, V.V.S.; Gupta, R.V.; Pandey, B.L.

    1997-01-01

    The Heavy Water Plant at Manuguru is designed to produce 185 MTY of nuclear grade heavy water based on bithermal H 2 S-H 2 O exchange process and handles large inventory of H 2 S gas (about 400 MT). As H 2 S gas is very toxic, corrosive and hazardous in nature, extreme care has been taken in the design of plant, selection of equipment and materials adhering to stringent fabrication procedures and codes to ensure the production of heavy water in a safe manner. This paper highlights the improvements done at Heavy Water Plant (Manuguru) to increase the standards of environmental protection. The safety assessment of a hazardous plant is a continuous process. Apart from the extreme care taken in the design, construction, commissioning and operation of the plant, review of each and every safety related unusual occurrence by various levels of review committees as stipulated and speedy implementation of the recommendations goes in a long way in increasing the standards of environmental protection

  15. Incorporation of {sup 137}Cs by tropical tree species and its correlation with plant physiology

    Energy Technology Data Exchange (ETDEWEB)

    Cid, Alberto Silva; Anjos, Roberto Meigikos dos; Macario, K.D.; Veiga, R.; Ayubi, J. Juri; Lacerda, T. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Instituto de Fisica; Zamboni, C.B.; Medeiros, I.M.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN- SP), Sao Paulo, SP (Brazil); Velasco, H.; Rizzotto, M. [Universidad Nacional de San Luis (UNSL) (Argentina). Instituto de Matematica Aplicada San Luis; Audicio, P. [Facultad de Ciencias (UDELAR), Montevideo (Uruguay). Centro de Investigaciones Nucleares

    2011-07-01

    Environmental phenomena associated with potential releases of radionuclides to terrestrial ecosystems have attracted the interest of several researches around the world. However, such interest has not been focused exclusively in its effects on human health. Several radionuclides have also been used as tracers of physicochemical or biological phenomena. These studies depend on both the development of auxiliary analysis techniques, which help to improve the results of traditional methods, and the production of additional data, so that a wide variety of natural processes can be understood. In this sense, the same radiometric results can be analyzed or interpreted from different viewpoints, allowing the interdisciplinary understanding of the overall structure of terrestrial ecosystems. {sup 137}Cs, for example, is one of the main fission products of nuclear reactors and atmospheric nuclear testing that is persistent in the biosphere because of its half-life of 30.2 years and biological mobility. This radionuclide remains in the top soil due to fixation and adsorption to clay minerals and organic matter, persisting in the root zone of plant for a long period of time. As its chemical behavior is similar to other monovalent inorganic cations (such as NH{sup +}{sub 4} , Na{sup +} and K{sup +}), Cs{sup +} can be readily absorbed by roots and translocated to the aboveground parts of plant. In this work, concentrations of {sup 137}Cs{sup +}, K{sup +} and Na{sup +} in fruits of lemon (Citrus limon B.) and coconut (Cocos nucifera L.) were measured by both gamma spectrometry and neutron activation analysis, with the aim to understand the behavior of monovalent inorganic cations in tropical plants as well as the plant ability to store these elements. In contrast to K{sup +} and Na{sup +}, Cs{sup +} is not an essential element to plants. However, our results have shown that {sup 137}Cs{sup +} incorporation to vegetal tissues is positively correlated to K{sup +} distribution inside

  16. Advanced digital instrumentation and control system for nuclear power plant protection

    Energy Technology Data Exchange (ETDEWEB)

    Sabino, D [VVER Engineering, Westinghouse Electric Corporation (United States)

    1998-12-31

    The Diverse Protection System is a back-up to the Primary Reactor Protection System developed for use at the Temelin nuclear power plant. The DPS is a digital system which provides a wealth of benefits from today`s advanced technology. These benefits include a compact hardware design with high performance microprocessors and a structured software design using a high level language. An overview of the DPS functions, hardware and software is provided. (author). 1 fig., 1 tab.

  17. Optimization of fire protection measures and quality controls in nuclear power plants

    International Nuclear Information System (INIS)

    Brenig, H.; Holtschmidt, H.; Liemersdorf, H.; Suetterlin, L.; Dobbernack, R.; Hahn, C.; Hosser, D.; Kordina, K.; Schneider, U.; Sprey, W.; Wesche, H.

    1985-09-01

    This study presents theoretical and experimental investigations on the evaluation of fire hazards and the optimization of fire protection measures in German nuclear power plants. Differences between the method presented here and the US ''Fire Hazard Analysis'' result from the inclusion of the stringent redundancy concept of German nuclear power plants and the emphasis placed on passive structural fire protection measures. The method includes a time-dependent quantification of fire-specific event sequences. Fire occurrence frequencies and the reliabilities of active fire protection measures were derived from German experiences and literature abroad. The reliability data of passive fire protection measures were obtained by an evaluation of experiments and probabilistic analyses. For the calculation of fire sequences fundamental experiments were taken into consideration. For the quantification of the time-dependent event trees a methodology was applied which permits an evaluation of the influence of the individual measures. The consequences of fire were investigated for ten fire events identified as decisive, and the fire sequence paths important in terms of safety were quantified. Their annual frequencies are within a range of 10 -3 to 8.10 -6 . (orig./HP) [de

  18. Incorporation of a recombinant Eimeria maxima IMP1 antigen into nanoparticles confers protective immunity against E. maxima challenge infection

    Science.gov (United States)

    The purpose of this study was to determine if incorporating a recombinant Eimeria maxima protein, namely rEmaxIMP1, into gold nanoparticles (NP) could improve the level of protective immunity against E. maxima challenge infection. Recombinant EmaxIMP1 was expressed in Escherchia coli as a poly-His f...

  19. Suggestions of radiation protection instruments in ships used for transporting spent fuel elements from nuclear power plants to central stores and further to fuel reprocessing plants

    International Nuclear Information System (INIS)

    Warenmo, G.

    1979-01-01

    Some radiation protection measures are necessary in ships which will be used for transporting spent fuel elements from nuclear power plants to central stores and further to fuel reprocessing plants in order to protect the crew from unnecessarily high radiation doses and to ensure that not allowable values occur. Such measures are discussed in this report as well as suitable radiation protection instruments for such ships. (E.R.)

  20. Added value by rule IEC61850. Modernizing the electrical protection of Gundremmingen nuclear power plant

    International Nuclear Information System (INIS)

    Hoetzel, A.; Willems, D.; Maier, K.L.; Herrmann, H.J.; Einsiedler, G.

    2006-01-01

    After many years in operation the large power plant generating units B and C at Gundremmingen nuclear power plant are due for inspection and maintenance, which also requires modernizing the electrical protection. Unlike the construction of new power plants, additional constraints apply to modernization in existing plants. The new solution has to fit as seamlessly as possible into the existing units, such as signaling systems with their multitude of signaling contacts and printers, or the connection to the power plant automation system. Apart from purely technical requirements, economic factors such as short standstill times, limited budgets or phased conversions also influence the choice of a suitable solution. Planning, construction and commissioning of the electrical generating unit protection was implemented by the Secondary Systems Technology Center, a technical department of RWE-Rhein-Ruhr Netzservice GmbH, in coordination with the operator. (orig.)

  1. Plant invasion science in protected areas: progress and priorities

    Czech Academy of Sciences Publication Activity Database

    Foxcroft, L. C.; Pyšek, Petr; Richardson, D. M.; Genovesi, P.; MacFadyen, S.

    2017-01-01

    Roč. 19, č. 5 (2017), s. 1353-1378 ISSN 1387-3547 R&D Projects: GA ČR GB14-36079G Grant - others:AV ČR(CZ) AP1002 Program:Akademická prémie - Praemium Academiae Institutional support: RVO:67985939 Keywords : plant invasions * global patterns * protected areas Subject RIV: EH - Ecology, Behaviour OBOR OECD: Biodiversity conservation Impact factor: 2.473, year: 2016

  2. Optimization of redundancy by using genetic algorithm for reliability of plant protection system

    International Nuclear Information System (INIS)

    Yoo, D. W.; Seong, S. H.; Kim, D. H.; Park, H. Y.; Gu, I. S.

    2000-01-01

    The design and development of a reliable protection system has been becoming a key issue in industry field because the reliability of system is considered as an important factor to perform the system's function successfully. Plant Protection System(PPS) guarantees the safety of plant by accident detection and control action against the transient conditions of plant. This paper presents the analysis of PPS reliability and the formal problem statement about optimal redundancy based on the reliability of PPS. And the optimization problem is solved by genetic algorithm. The genetic algorithm is a useful tool to solve the problems, in the case of large searching, complex gradient, existence local minimum. The effectiveness of the proposed optimization technique is proved by the target reliability of one channel of PPS, using the failure rate based on the MIL-HDBK-217

  3. Reliability data of fire protection equipment and features in German nuclear power plants

    International Nuclear Information System (INIS)

    Roewekamp, M.; Riekert, T.; Sehrbrock, W.

    1997-01-01

    In order to perform probabilistic fire safety analyses, a comprehensive data base is needed including physical characteristics of fire compartments and their inventory, fire occurrence frequencies, technical reliability data for all fire-related equipment, human actions and human error probabilities, etc. In order to provide updated and realistic reliability data, the operational behaviour of different fire protection features in two German nuclear power plants was analysed in the framework of the study presented here. The analyses are based on the examination of reported results of the regular inspection and maintenance programs for nuclear power plants. Besides a plant specific assessment of the reliability data a generic assessment for an application as input data for fault tree analyses in the framework of probabilistic risk studies for other German plants was carried out. The analyses of failures and unavailabilities gave the impression that most of them are single failures without relevance for the plant safety. The data gained from NPPs were compared to reliability data of the German insurance companies for the same protection features installed in non-nuclear installations and to older nuclear specific reliability data. This comparison showed up a higher reliability. (orig.) [de

  4. How nitric oxide donors can protect plants in a changing environment: what we know so far and perspectives

    Directory of Open Access Journals (Sweden)

    Amedea B. Seabra

    2016-12-01

    Full Text Available The free radical nitric oxide (NO plays important roles in plant growth and defense. Owing to its small size and lipophilicity, NO acts as a crucial signaling molecule in plants, crossing cell membranes and enhancing cell communication. Indeed, NO donors have been shown to modulate a variety of physiological processes, such as plant greening, seed germination, iron homeostasis and mitochondrial respiration. Recently, several papers have reported the protective actions upon application of low molecular weight NO donors in plants under abiotic stress. Exogenous NO is able to improve plant tolerance to several abiotic stresses, such as drought, salinity, metal toxicity, and extreme temperatures. This protection is assigned to the NO-mediated redox signaling in plants, which involves interplay with reactive oxygen species and modulation of gene expression and protein function. This review reports and discusses the recent advantages, pitfalls, challenges, and perspectives in the applications of low molecular weight NO donors in plants under abiotic stress. The combination of nanotechnology and NO donors as an efficient approach to protect plants under challenging environments is also discussed.

  5. Security aspects and radiological protection analyzed in the Semi-industrial irradiation plant in Peru

    International Nuclear Information System (INIS)

    Del Valle O, C.

    1996-01-01

    The safety aspects and the radiological protection analyzed on regular and emergency operation of a multipurpose irradiation plant PIMU are shown. All its design requirements are described following a strict safety philosophy. The plant is classified into the generic category IV for storage in pool panoramic irradiators. This paper studies every aspect related to a safety operation of the gamma's facility, PIMU, being used as reference in order to obtain the corresponding licensing. Aspects related to the regular and safety operation of the whole plant are taken into account, so all the possible emergency cases and their respective answers will be known, analyzing cases and causes of accidents, as well as references to the program of radiological protection. Registers and documents are written in order to be used at the plant, all the lineament for the development of a good preventive and corrective maintenance are given, observing all the necessary adjustments. A list of the principal examinations of the technical condition of the plant is presented. (author). 2 refs

  6. Vehicle bomb protection for nuclear power plants

    International Nuclear Information System (INIS)

    James, J.W.; Veatch, J.D.; Goldman, L.; Massa, R.

    1989-01-01

    The six-step methodology presented in this paper can be applied to nuclear power reactors to provide protection measures and considerations against vehicle bomb threats. The methodology provides a structured framework for examining the potential vulnerability of a plant to a postulated vehicle bomb and for developing contingency planning strategies for dealing with such a possibility. The six steps are as follows: (1) identify system options available to establish and maintain a safe reactor shutdown; (2) identify buildings or other structures containing critical components and equipment associated with each system option; (3) determine survival envelopes for the system options; (4) review site features to determine vehicle access approach paths and distances as they relate to the survival envelopes; (5) identify measures to limit or thwart vehicle access, and protect and preserve preferred system options; (6) prepare contingency plans and make advance arrangements for implementation of contingency measures for a vehicle bomb attack. Portions of this methodology related to blast effects from vehicle bombs on power reactor components are implemented using BombCAD, a proprietary computer-aided design (CAD)-based blast effects analysis technique

  7. Cernavoda nuclear power plant: Modifications in the fire protection measures of the CANDU 6 standard design

    International Nuclear Information System (INIS)

    Covalschi, V.

    1998-01-01

    Having as purpose the improvement of fire safety at the Cernavoda NPP - both in the prevention and the protection aspects in the case of fire - we implemented some modifications in the CANDU 6 standard design. These improvements are inspired, mainly, from two sources: the world-wide achievements in the field of fire protection techniques, introduced in nuclear power plants since the middle of 70's, when the CANDU 6 design was completed; the national practice and experience in fire protection, usually applied in industrial objectives (conventional power plants, in particular). The absence of any incident may be considered as a proof of the efficiency of the implemented fire preventing and protection measures. (author)

  8. Fabrication of nanoporous Sr incorporated TiO{sub 2} coating on 316L SS: Evaluation of bioactivity and corrosion protection

    Energy Technology Data Exchange (ETDEWEB)

    Anne Pauline, S. [Department of Chemistry, Anna University, Chennai 600025 (India); Kamachi Mudali, U. [Corrosion Science and Technology Section, IGCAR, Kalpakkam 603102 (India); Rajendran, N., E-mail: nrajendran@annauniv.edu [Department of Chemistry, Anna University, Chennai 600025 (India)

    2013-10-01

    In this paper, nanoporous TiO{sub 2} and Sr-incorporated TiO{sub 2} coated 316L SS were prepared by sol–gel methodology. The effect of Sr incorporation into TiO{sub 2} coating on bioactivity and corrosion resistance was investigated. Attenuated total reflectance–Fourier transform infrared (ATR–FTIR) spectroscopy, X-ray diffraction analysis (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) results obtained after in vitro bioactivity test confirm the excellent growth of crystalline hydroxyapatite (HAp) over nanoporous Sr-incorporated TiO{sub 2} coated 316L SS which may be attributed to the slow and steady release of Sr ions from the coatings. The electrochemical evaluation of the coatings confirms that Sr-incorporated TiO{sub 2} coating offer excellent protection to 316L SS by acting as a barrier layer. The results showed that the incorporation of Sr enhanced both bioactivity and corrosion resistance of 316L SS. Hence Sr-incorporated TiO{sub 2} coated 316L SS is a promising material for orthopaedic implant applications. - Highlights: • Nanoporous Sr-incorporated TiO{sub 2} coatings were successfully fabricated on 316L SS. • The coatings have excellent adhesion to the substrate and appreciable Vickers micro hardness value. • Sr-incorporated TiO{sub 2} coated specimens exhibited excellent hydroxyapatite growth due to slow release of Sr from the coating. • Sr incorporation enhances the corrosion resistance of TiO{sub 2} coating.

  9. Predicting the presence and cover of management relevant invasive plant species on protected areas.

    Science.gov (United States)

    Iacona, Gwenllian; Price, Franklin D; Armsworth, Paul R

    2016-01-15

    Invasive species are a management concern on protected areas worldwide. Conservation managers need to predict infestations of invasive plants they aim to treat if they want to plan for long term management. Many studies predict the presence of invasive species, but predictions of cover are more relevant for management. Here we examined how predictors of invasive plant presence and cover differ across species that vary in their management priority. To do so, we used data on management effort and cover of invasive plant species on central Florida protected areas. Using a zero-inflated multiple regression framework, we showed that protected area features can predict the presence and cover of the focal species but the same features rarely explain both. There were several predictors of either presence or cover that were important across multiple species. Protected areas with three days of frost per year or fewer were more likely to have occurrences of four of the six focal species. When invasive plants were present, their proportional cover was greater on small preserves for all species, and varied with surrounding household density for three species. None of the predictive features were clearly related to whether species were prioritized for management or not. Our results suggest that predictors of cover and presence can differ both within and across species but do not covary with management priority. We conclude that conservation managers need to select predictors of invasion with care as species identity can determine the relationship between predictors of presence and the more management relevant predictors of cover. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Safety analysis of an expert reactor protection system in nuclear power plants

    International Nuclear Information System (INIS)

    El-Kafas, A.A.

    1997-01-01

    The purpose of the dissertation is to develop real time expert reactor protection system (ERPS) for operational safety of pressurized water reactor nuclear power plant. The system is developed to diagnose plant failures and for identification plant transients (with and without scram). For this erps, probabilistic safety analysis techniques are used to check the availability and priority of the recommended safety system in case of plant accidents. The real - time information during transients and accidents can be obtained to assess the operator in his decision - making. Also, the ERPS is able to give advice for the reactor operator to take the appropriate corrective action during abnormal situations. 5-15 figs., 42 refs

  11. Applying formal method to design of nuclear power plant embedded protection system

    International Nuclear Information System (INIS)

    Kim, Jin Hyun; Kim, Il Gon; Sung, Chang Hoon; Choi, Jin Young; Lee, Na Young

    2001-01-01

    Nuclear power embedded protection systems is a typical safety-critical system, which detects its failure and shutdowns its operation of nuclear reactor. These systems are very dangerous so that it absolutely requires safety and reliability. Therefore nuclear power embedded protection system should fulfill verification and validation completely from the design stage. To develop embedded system, various V and V method have been provided and especially its design using Formal Method is studied in other advanced country. In this paper, we introduce design method of nuclear power embedded protection systems using various Formal-Method in various respect following nuclear power plant software development guideline

  12. Incorporation of oxygen contribution by plant roots into classical dissolved oxygen deficit model for a subsurface flow treatment wetland.

    Science.gov (United States)

    Bezbaruah, Achintya N; Zhang, Tian C

    2009-01-01

    It has been long established that plants play major roles in a treatment wetland. However, the role of plants has not been incorporated into wetland models. This study tries to incorporate wetland plants into a biochemical oxygen demand (BOD) model so that the relative contributions of the aerobic and anaerobic processes to meeting BOD can be quantitatively determined. The classical dissolved oxygen (DO) deficit model has been modified to simulate the DO curve for a field subsurface flow constructed wetland (SFCW) treating municipal wastewater. Sensitivities of model parameters have been analyzed. Based on the model it is predicted that in the SFCW under study about 64% BOD are degraded through aerobic routes and 36% is degraded anaerobically. While not exhaustive, this preliminary work should serve as a pointer for further research in wetland model development and to determine the values of some of the parameters used in the modified DO deficit and associated BOD model. It should be noted that nitrogen cycle and effects of temperature have not been addressed in these models for simplicity of model formulation. This paper should be read with this caveat in mind.

  13. Safety and environmental protection - realization efforts regarding the authorization of power engineering plants

    International Nuclear Information System (INIS)

    Dreyhaupt, F.J.

    1982-01-01

    As to power plants the author calls special attention to three statements concerning questions on safety and environmental protection which play a decisive part in authorizing conventional and nuclear facilities. After investigating the most important legal fundamental principles for the authorization of power engineering plants, the Atomic Act and the Federal Immission Protection Act, the author discusses the problems that arise with the application of the authorization procedures. The reasons which can be made responsible for the long running periods of the authorization procedures and therewith of the realization of the site installation work are given. Finally, the author describes and judges the outlines of regulations for large scale furnaces and for the TA-air supplementary clause. (orig.) [de

  14. An evaluation method of fault-tolerance for digital plant protection system in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Jun Seok; Kim, Man Cheol; Seong, Poong Hyun; Kang, Hyun Gook; Jang, Seung Cheol

    2005-01-01

    In recent years, analog based nuclear power plant (NPP) safety related instrumentation and control (I and C) systems have been replaced to modern digital based I and C systems. NPP safety related I and C systems require very high design reliability compare to the conventional digital systems so that reliability assessment is very important. In the reliability assessment of the digital system, fault tolerance evaluation is one of the crucial factors. However, the evaluation is very difficult because the digital system in NPP is very complex. In this paper, the simulation based fault injection technique on simplified processor is used to evaluate the fault-tolerance of the digital plant protection system (DPPS) with high efficiency with low cost

  15. Inactivated recombinant plant virus protects dogs from a lethal challenge with canine parvovirus.

    Science.gov (United States)

    Langeveld, J P; Brennan, F R; Martínez-Torrecuadrada, J L; Jones, T D; Boshuizen, R S; Vela, C; Casal, J I; Kamstrup, S; Dalsgaard, K; Meloen, R H; Bendig, M M; Hamilton, W D

    2001-06-14

    A vaccine based upon a recombinant plant virus (CPMV-PARVO1), displaying a peptide derived from the VP2 capsid protein of canine parvovirus (CPV), has previously been described. To date, studies with the vaccine have utilized viable plant chimaeric particles (CVPs). In this study, CPMV-PARVO1 was inactivated by UV treatment to remove the possibility of replication of the recombinant plant virus in a plant host after manufacture of the vaccine. We show that the inactivated CVP is able to protect dogs from a lethal challenge with CPV following parenteral immunization with the vaccine. Dogs immunized with the inactivated CPMV-PARVO1 in adjuvant displayed no clinical signs of disease and shedding of CPV in faeces was limited following CPV challenge. All immunized dogs elicited high titres of peptide-specific antibody, which neutralized CPV in vitro. Levels of protection, virus shedding and VP2-specific antibody were comparable to those seen in dogs immunized with the same VP2- peptide coupled to keyhole limpet hemocyanin (KLH). Since plant virus-derived vaccines have the potential for cost-effective manufacture and are not known to replicate in mammalian cells, they represent a viable alternative to current replicating vaccine vectors for development of both human and veterinary vaccines.

  16. Radiation protection aspects in the design of nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2008-01-01

    . The IAEA takes seriously the enduring challenge for users and regulators everywhere: that of ensuring a high level of safety in the use of nuclear materials and radiation sources around the world. Their continuing utilization for the benefit of humankind must be managed in a safe manner, and the IAEA safety standards are designed to facilitate the achievement of that goal. This Safety Guide has been prepared as a part of the IAEA programme on safety standards for nuclear power plants. It includes recommendations on how to satisfy the requirements established in the Safety Requirements publication on the Safety of Nuclear Power Plants: Design. It addresses the provisions that should be made in the design of nuclear power plants in order to protect site personnel, the public and the environment against radiological hazards for operational states, decommissioning and accident conditions. The recommendations on radiation protection provided in this Safety Guide are consistent with the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS), which were jointly sponsored by the Food and Agriculture Organization of the United Nations (FAO), the IAEA, the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO). This Safety Guide supersedes Safety Series No. 50-SG-D9, Design Aspects of Radiation Protection for Nuclear Power Plants, published in 1985. Effective radiation protection is a combination of good design, high quality construction and proper operation. Procedures that address the radiation protection aspects of operation are covered in the Safety Guide on Radiation Protection and Radioactive Waste Management in the operation of Nuclear Power Plants

  17. Amphibians and plant-protection products: what research and action is needed?

    Science.gov (United States)

    Aldrich, Annette; Junghans, Marion; Aeberli, Caroline; Brühl, Carsten A; Streissl, Franz; Schmidt, Benedikt R

    2016-01-01

    The majority of Swiss amphibians are threatened. There is a range of factors which have been discussed as possible causes for their decline, including plant protection products (PPPs). The influence of PPPs on amphibian populations has not yet been studied to any great extent, neither for active ingredients nor for the wetting agents, breakdown products or tank mixtures. A further topic of discussion was how to better protect amphibians by reducing their exposure to PPPs in agricultural fields. Experts at a workshop concluded that further research is needed.

  18. The regulatory evaluation of radiation protection training programmes at Canadian nuclear power plants

    International Nuclear Information System (INIS)

    Legare, M.; Tennant, D.

    1996-01-01

    The responsibility for providing the necessary assurance that the use of nuclear energy in Canada does not pose undue risk to health, safety, security and the environment is vested with the Atomic Energy Control Board (AECB). This responsibility has led the Operator Certification Division of the AECB to develop methods to obtain assurance that nuclear power plant operations personnel are well trained and adequately competent to perform their duties. The features of the AECB approach to evaluation of training programmes based on a systematic approach to training is described. An overview of the Canadian nuclear power plants' radiation protection qualification levels is given. The developing evaluation process is contributing to the improvement of licensee radiation protection training programmes. This is making possible the transfer of part of the responsibility for licensed personnel radiation protection qualification assessment to the licensees, thus enabling a reduction in the operator certification division formal qualification activities. (author)

  19. Safety design of Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Ouyang Yu; Zhang Lian; Du Shenghua; Zhao Jiayu

    1984-01-01

    Safety issues have been greatly emphasized through the design of the Qinshan Nuclear Power Plant. Reasonable safety margine has been taken into account in the plant design parameters, the design incorporated various safeguard systems, such as engineering safety feature systems, safety protection systems and the features to resist natural catastrophes, e. g. earthquake, hurricanes, tide and so on. Preliminary safety analysis and environmental effect assessment have been done and anti-accident provisions and emergency policy were carefully considered. Qinshan Nuclear Power Plant safety related systems are designed in accordance with the common international standards established in the late 70's, as well as the existing engineering standard of China

  20. TECHNICAL AND TECHNOLOGICAL ASPECTS IN PLANT PROTECTION IN THE PRECISION FARMING SYSTEM

    Directory of Open Access Journals (Sweden)

    Mladen Jurišić

    2015-06-01

    Full Text Available The basic premise of precision farming as a larger amount of information is its availability to the farmer in making decision. Direct comparison of perennial parameters obtained from the plot results in purposefully, argumentative and optimal use of resources for work (while keeping in mind the ecological impact. Today, the development of satellite navigation technology and monitoring of agricultural machinery, and reducing the cost of these devices again revived the question of the precision agriculture application. Advanced farmers in developed agricultural countries already regularly apply some of the technological possibilities of precision farming. Precision agriculture and plant protection allow the farmer realizing high incomes while keeping safe natural resources. Using modern GIS technology machines collect data directly from the plot using sensors and integrate themselves into the data processing system. Processed information is used by a farmer taking GreenStar system for the new planned operation and achieving significant time and money spare. Precision agriculture offers the possibility of optimal care of each plant, not just the average, or the entire field. Low risk investments are one of the main factors of choice precise plant protection. The use of pilotless aircrafts remote sensing allow fast and economical obtaining data and sufficient precision information. Using modern technology such as Variable Rate Application (applying a variable volume and GreenStar software package it is possible to regulate the amount of care and protection.

  1. Incorporation Between AHP and N-TSP for Plant Surveillance Routing with Multiple Constraints

    International Nuclear Information System (INIS)

    Djoko Hari Nugroho

    2002-01-01

    This paper observed plant on-line surveillance routing for maintenance management with multiple constraints using TSP (Traveling Salesman Problem). In the research N-TSP (nomadic TSP) type was used. In this case, on-line surveillance could be implemented on moving robot. Route for preventive maintenance management was observed sequentially per stage using multiple constraints (a) distance between components, and (b) failure probability of components using AHP (Analytical Hierarchy Process). Simulation was observed utilizing DURESS as a complex system. The simulation result showed that the route with single constraint distance between components represents the sequence of 1 - 6 - 2 - 4 - 3 - 5. Routing for DURESS with multiple constraints using incorporation of AHP and TSP showed that the first priority in the route is flow sensor FB2 with the value of comparation of 0.1042. The next priority is sequentially FB1, FA2, FA1, FA, FB, VB, VA, VA1, VA2, VB1, VB2, pump B, pump A, FR1, FR2, reservoir 2, and reservoir 1. Numerical experiment obtained that the incorporation between AHP and N-TSP has successfully constructed the surveillance routing with multiple constraints. (author)

  2. Inspection of fire protection measures and fire fighting capability at nuclear power plants. A publication within the NUSS programme

    International Nuclear Information System (INIS)

    1994-01-01

    The present publication has been developed with the help of experts from regulatory, operating and engineering organizations, all with practical experience in the field of fire protection of nuclear power plants. The publication outlines practices for inspecting the fire protection measures at nuclear power plants in accordance with Safety Series No.50-SG-D2(Rev.1), Fire Protection in Nuclear Power Plants, and includes a comprehensive fire safety inspection checklist of the specific elements to be addressed when evaluating the adequacy and effectiveness of the fire protection measures and manual fire fighting capability available at operating nuclear power plants. The publication will be useful not only to regulators and safety assessors but also to operators and designers. The book addresses a specialized topic and it is recommended that it be used in conjunction with Safety Guide No.50-SG-D2(Rev.1)

  3. Soil microflora and enzyme activities in rhizosphere of Transgenic Bt cotton hybrid under different intercropping systems and plant protection schedules

    Science.gov (United States)

    Biradar, D. P.; Alagawadi, A. R.; Basavanneppa, M. A.; Udikeri, S. S.

    2012-04-01

    Field experiments were conducted over three rainy seasons of 2005-06 to 2007-08 on a Vertisol at Dharwad, Karnataka, India to study the effect of intercropping and plant protection schedules on productivity, soil microflora and enzyme activities in the rhizosphere of transgenic Bt cotton hybrid. The experiment consisted of four intercropping systems namely, Bt cotton + okra, Bt cotton + chilli, Bt cotton + onion + chilli and Bt cotton + redgram with four plant protection schedules (zero protection, protection for Bt cotton, protection for intercrop and protection for both crops). Observations on microbial populations and enzyme activities were recorded at 45, 90, 135 and 185 (at harvest) days after sowing (DAS). Averaged over years, Bt cotton + okra intercropping had significantly higher total productivity than Bt cotton + chilli and Bt cotton + redgram intercropping system and was similar to Bt cotton + chilli + onion intercropping system. With respect to plant protection schedules for bollworms, protection for both cotton and intercrops recorded significantly higher yield than the rest of the treatments. Population of total bacteria, fungi, actinomycetes, P-solubilizers, free-living N2 fixers as well as urease, phosphatase and dehydrogenase enzyme activities increased up to 135 days of crop growth followed by a decline. Among the intercropping systems, Bt cotton + chilli recorded significantly higher population of microorganisms and enzyme activities than other cropping systems. While Bt cotton with okra as intercrop recorded the least population of total bacteria and free-living N2 fixers as well as urease activity. Intercropping with redgram resulted in the least population of actinomycetes, fungi and P-solubilizers, whereas Bt cotton with chilli and onion recorded least activities of dehydrogenase and phosphatase. Among the plant protection schedules, zero protection recorded maximum population of microorganisms and enzyme activities. This was followed by the

  4. Radiation protection programme at Krsko nuclear power plant

    International Nuclear Information System (INIS)

    Breznik, B.

    1996-01-01

    Krsko NPP, a Westinghouse two-loop PWR of 632 M We power, is in commercial operation since 1982. Reduction of radioactive releases to the environment and the reduction of doses to workers is the basic goal in the plant radiological protection. The radiation protection programme is established to ensure that the radiation exposures to workers and members of the public are minimized according to the As Low As Reasonably Achievable approach and controlled in accordance with international safety standards and Slovenian regulations. The basis for the operational and technical measures has been provided according to the industrial good practice. The effluent control is based on the Standard Radioactive Effluent Technical Specifications, and environmental surveillance is established according to the programme defined by the regulations. The dose constraints and performance indicators are used to assure the effectiveness of the radiation protection programme and provide a convenient follow-up tool. The monitoring programme results of each year show that there is no measurable dose to the public due to radioactive releases. The commitment to the dose burden of any member of a critical group is assessed to be below the dose constraint. Individual and collective doses of the workers are within a range typical for the PWRs of a similar type. (author)

  5. Safety analysis of an expert reactor protection system in nuclear power plants

    International Nuclear Information System (INIS)

    EL-Kafas, A.E.A.E.

    1996-01-01

    the purpose of the dissertation is to develop a real time expert reactor protection system (ERPS) for operational safety of pressurized water reactor nuclear power plant. The system is developed to diagnose plant failures and for identification of plant transients (with and without scram). for this ERPS. probabilistic safety analysis techniques are used to check the availability and priority of the recommended safety system in case of plant accidents . the real- time information during transients and accidents can be obtained to asses the operator in his decision - making . Also, the ERPS is able to give advice for the reactor operator to take the appropriate corrective action during abnormal situations. The system model consists of the dynamic differential equations for reactor core, pressurizer, steam generator, turbine and generator, piping and plenums. The system of equations can be solved by appropriate codes also displayed directly from sensors of the plant. All scenarios of transients, accidents and fault tress for plant systems are learned to ERPS

  6. Studies in biogas technology. Part 4. A noval biogas plant incorporating a solar water-heater and solar still

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, A K.N. [Indian Inst. of Science, Bangalore; Prasad, C R; Sathyanarayan, S R.C.; Rajabapaiah, P

    1979-09-01

    A reduction in the heat losses from the top of the gas holder of a biogas plant has been achieved by the simple device of a transparent cover. The heat losses thus prevented have been deployed to heat a water pond formed on the roof of the gas holder. This solar-heated water is mixed with the organic input for hot-charging of the biogas plant. To test whether the advantages indicated by a thermal analysis can be realized in practice, a biogas plant of the ASTRA design was modified to incorporate a roof-top water-heater. The operation of such a modified plant, even under worst case conditions, shows a significant improvement in the gas yield compared to the unmodified plant. Hence, the innovation reported here may lead to drastic reductions in the sizes and therefore costs of biogas plants. By making the transparent cover assume a tent-shape, the roof-top solar heater can serve the additional function of a solar still to yield distilled water. The biogas plant-cum-solar still described here is an example of a spatially integrated hybrid device which is extremely cost-effective.

  7. Radiation protection training for personnel at light-water-cooled nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Section 19.12 Instructions to Workers, of 10 CFR Part 19, Notices, Instructions, and Reports to Workers; Inspections, requires that individuals be given instruction in radiation protection that is commensurate with the potential radiation protection problems they may encounter in restricted areas as defined in para. 19.3(e) of 10 CFR Part 19. Para. 20.1(c) of 10 CFR Part 20, Standards for Protection Against Radiation, states that occupational radiation exposure should be kept as low as is reasonably achievable (ALARA). Appropriate training is an essential aspect of an ALARA program. This guide describes a radiation protection training program consistent with the ALARA objective and acceptable to the NRC staff for meeting the training requirements of 10 CFR Part 19 with respect to individuals that enter restricted areas at nuclear power plants

  8. Carbon steel protection in G.S. [Girldler sulphide] plants: Pt.9

    International Nuclear Information System (INIS)

    Rojo, Enrique.

    1990-01-01

    In heavy water plants that use the bithermal exchange H 2 S-H 2 O, a protective scale against corrosion is formed by the action of a solution of H 2 S at high temperature for a tile between 10 to 14 days. Exposure to humid air during plant shutdown produces an oxidation of the scale. The reexposure to the H 2 S-H 2 O at low temperature do not regenerate the original properties of the scale. It was concluded that a relative humidity of 50 % was enough to exclude the oxidation for a period of several months. (Author) [es

  9. Safety and Radiation Protection at Swedish Nuclear Power Plants 2007

    Energy Technology Data Exchange (ETDEWEB)

    2008-07-01

    The safety level of the plants is maintained at an acceptable level. SKI has in its regulatory supervision not found any known deficiencies in the barriers which could result in release of radioactive substances in excess of the permitted levels. SKI considers that improvements have been implemented during the year in the management, control and following up of safety work at the plants. In some cases, SKI has imposed requirements that improvements be made. Extensive measures are under way at the nuclear power plants to comply with the safety requirements in SKI's regulations, SKIFS 2004:2 concerning the design and construction of nuclear power reactors, and the stricter requirements regarding physical protection. Concurrently preparations are underway at eight of the ten units for thermal power increases. At the Forsmark plant considerable efforts have been during the year to correct the deficiencies in the safety culture and quality assurance system that became apparent in 2006. A programme to improve the execution of activities has been established in accordance with SKI's decision. SKI considers that the plant has developed in a positive direction but that there are further possibilities for improvement with regard to internal control. This is amongst other things concerns the areas internal auditing, independent safety review function, and working methods. SKI has had special supervision of the plant since 28 September, 2006. At the Oskarshamn plant work has been carried out to improve the organisation and routines in several areas. The plant has established routines which provide the basis to ensure that decisions are taken in a stringent manner. The quality assurance system has a clearer structure and there is a better defined division of work. Some measures remain to be dealt with in 2008. The Ringhals plant has also worked with attitudes to routines and internal control. SKI considers that the measures have good prerequisites to provide a

  10. State-of-the-art explosion protection for dedusting of coal grinding plants; Explosionsschutz fuer die Entstaubung von Kohlemahlanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Neuhaus, Tim [Intensiv-Filter GmbH und Co. KG, Velbert-Langenberg (Germany). Development; Schrooten, Theo [Intensiv-Filter GmbH und Co. KG, Velbert-Langenberg (Germany). Technology Dept.; Baldauf, Joerg [Thorwesten Vent GmbH, Beckum (Germany). Sales

    2010-07-01

    With dedusting of coal grinding plants, the state of the technology is determined by the explosion protection measures, the filtration performance and the design of the plant. To ensure safe operation of a plant, only certified and tested concepts and components should be used for its design and manufacture. With plants protected against explosion, such issues will always affect the plant's resistance, its explosion relief venting and its explosion decoupling systems. Economic factors, where the aim is minimising the filter level and lean design, should not be forgotten with dedusting and it is important that plants are aligned to the latest state of technological development. With their years of experience and continuing development in the area of dedusting for coal grinding plants, Intensiv-Filter and Thorwesten Vent have succeeded in implementing the state of the art. (orig.)

  11. ECONOMIC MODEL AND TOOLS OF THE AIR PROTECTION MANAGEMENT BASED ON THE EXAMPLE OF A COKING PLANT

    Directory of Open Access Journals (Sweden)

    Danuta Hilse

    2014-10-01

    Full Text Available Legal-economic models of the air protection management at the Polish industrial plants, which take into account the regulations of the Act on “Environment protection law”, are far from being perfect. It is particularly noticeable in the coking industry where chargeable pollutions are chosen selectively, and unitary rates of emission charges are agreed at random. Tax deductions are not granted either to producers of fuel coke for reduction of pollutants emission in municipal-housing management after replacing coal with fuel coke. The proposed new economic model of the air protection management at coking plants eliminates the existing shortcomings.

  12. Ultraviolet-B-effects on plants: Spectra of harmful effects, primary damage and UV protective mechanisms

    International Nuclear Information System (INIS)

    Wellmann, E.; Beggs, C.; Moehle, B.; Schneider-Ziebert, U.; Steinmetz, V.; Koch, U.

    1986-01-01

    In two model systems of higher plants, damage caused by ultraviolet-B-radiation was analysed as to its mechanism of action and the spectral quantum efficiency. These investigations were to provide information on the relevance of such UV effects in cases of increased ultraviolet-B-irradiation owing to the destruction of ozone. The results indicate the very high tolerance of the plants to ultraviolet-B-radiation which obviously is the result of very effective protective mechanisms, and show at the same time that potential damage must already be reckoned with, given the current share of ultraviolet-B-radiation in solar radiation. Should ultraviolet-B-radiation be increased, then indirect damage to the plant from the destruction of ultraviolet protective mechanisms through UV-B-radiation will probably constitute a particular risk. (orig./MG) [de

  13. Material protection control and accounting program activities at the Urals electrochemical integrated plant

    International Nuclear Information System (INIS)

    McAllister, S.

    1997-01-01

    The Urals Electrochemical Integrated Plant (UEIP) is the Russian Federation's largest uranium enrichment plant and one of three sites in Russia blending high enriched uranium (HEU) into commercial grade low enriched uranium. UEIP is located approximately 70 km north of Yekaterinburg in the closed city of Novouralsk (formerly Sverdlovsk- 44). DOE's MPC ampersand A program first met with UEIP in June of 1996, however because of some contractual issues the work did not start until September of 1997. The six national laboratories participating in DOE's Material Protection Control and Accounting program are cooperating with UEIP to enhance the capabilities of the physical protection, access control, and nuclear material control and accounting systems. The MPC ampersand A work at UEIP is expected to be completed during fiscal year 2001

  14. Guideline on radiation protection requirements for ionizing radiation shielding in nuclear power plants

    International Nuclear Information System (INIS)

    1988-01-01

    The guideline which entered into force on 1 May 1988 stipulates the radiation protection requirements for shielding against ionizing radiation to be met in the design, construction, commissioning, operation, and decommissioning of nuclear power plants

  15. Kainic Acid-Induced Excitotoxicity Experimental Model: Protective Merits of Natural Products and Plant Extracts

    Directory of Open Access Journals (Sweden)

    Nur Shafika Mohd Sairazi

    2015-01-01

    Full Text Available Excitotoxicity is well recognized as a major pathological process of neuronal death in neurodegenerative diseases involving the central nervous system (CNS. In the animal models of neurodegeneration, excitotoxicity is commonly induced experimentally by chemical convulsants, particularly kainic acid (KA. KA-induced excitotoxicity in rodent models has been shown to result in seizures, behavioral changes, oxidative stress, glial activation, inflammatory mediator production, endoplasmic reticulum stress, mitochondrial dysfunction, and selective neurodegeneration in the brain upon KA administration. Recently, there is an emerging trend to search for natural sources to combat against excitotoxicity-associated neurodegenerative diseases. Natural products and plant extracts had attracted a considerable amount of attention because of their reported beneficial effects on the CNS, particularly their neuroprotective effect against excitotoxicity. They provide significant reduction and/or protection against the development and progression of acute and chronic neurodegeneration. This indicates that natural products and plants extracts may be useful in protecting against excitotoxicity-associated neurodegeneration. Thus, targeting of multiple pathways simultaneously may be the strategy to maximize the neuroprotection effect. This review summarizes the mechanisms involved in KA-induced excitotoxicity and attempts to collate the various researches related to the protective effect of natural products and plant extracts in the KA model of neurodegeneration.

  16. Multiple stress by repeated use of plant protection products in agricultural areas

    NARCIS (Netherlands)

    Luttik, R.; Zorn, M.I.; Brock, T.C.M.; Roex, E.W.M.; Linden, van der A.M.A.

    2017-01-01

    Current risk assessment of plant protection products is performed on a formulated-product-by-formulated-product basis and does not take into account the fact that products may be mixed and/or that different products are used sequentially within a growing season. This report evaluates three

  17. Proposal of a concept and reliability analysis for a fusion plant magnet protection system

    International Nuclear Information System (INIS)

    Schnauder, H.; Pamfilie, E.

    1993-05-01

    The unavailability for the current switch down in case of a demand in the magnet coils of a fusion demonstration plant must be decreased by a few orders of magnitude as compared to the one of experimental facilities. The safety requirements to prevent initiation of event sequences which might lead to the release of radioactivity and energy by the plant must be fulfilled with the same standards as applied in a normally applicable plant. On the basis of this proven technology a general usable magnet protection system will be proposed, which achieves some considerable improvements in the failure detectability as compared to the conventional protection systems. It will be demonstrated by fault tree analysis that the principal demands on safety can be satisfied by that approach. The improvements are achieved by the use of an additional microprocessor supported system for failure detection without being used for initiation of any safety related actions. An influence on a safety action by the additional system therefore is excluded. (orig.) [de

  18. Transport, acceptance, storage and handling of the itens of nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    The norm aiming to establish the requirements applied to workers or organizations which participate of the activities of transport, acceptance, storage and handling of important itens for safety of nuclear power plants, is presented. The established requirements treat of protection and control necessary to assure that the quality of important itens for safety be it preserved from the end of fabrication until their incorporation to nuclear power plant. (M.C.K.) [pt

  19. Radiation protection measures for reduction of incorporations of iodine-131 by the staff of a radionuclide therapy ward

    International Nuclear Information System (INIS)

    Petzold, J.; Meyer, K.; Lincke, T.; Sabri, O.; Alborzi, H.; Lorenz, J.; Schoenmuth, T.; Keller, A.

    2009-01-01

    The air in patient's rooms with thyroid therapies is loaded with iodine 131, which is to be seen as a cause for the incorporation of iodine 131 by the staff. The patients exhale a part of the iodine applied for their intended radionuclide therapy. The activity is concentrated in the saliva and, thereby, the breath air is moistened and iodine reaches the exhaled and compartment air. The detection of iodine in the form of contaminations and/or incorporations with the staff succeeds only after a longer stay in the patient's room. With this, a clear relation between the particular type of work performed in the room and therapy of malignant thyroid disease with high amounts of radioactivity can be found. The measured values of incorporations, obtained with an whole-body counter, are in the range of up to 400Bq. The activity concentration in the compartment air some hours after application of the therapeutic activity reaches a maximum and then decreases with a half-life of about 15 hours. As a protection measure we asked the patients wearing a mask up to 30 hours after application to (orig.)

  20. Safety and Radiation Protection at Swedish Nuclear Power Plants 2007

    International Nuclear Information System (INIS)

    2008-01-01

    The safety level of the plants is maintained at an acceptable level. SKI has in its regulatory supervision not found any known deficiencies in the barriers which could result in release of radioactive substances in excess of the permitted levels. SKI considers that improvements have been implemented during the year in the management, control and following up of safety work at the plants. In some cases, however, SKI has imposed requirements that improvements be made. Extensive measures are under way at the nuclear power plants to comply with the safety requirements in SKI's regulations, SKIFS 2004:2 concerning the design and construction of nuclear power reactors, and the stricter requirements regarding physical protection. Concurrently preparations are underway at eight of the ten units for thermal power increases. At the Forsmark plant considerable efforts have been during the year to correct the deficiencies in the safety culture and quality assurance system that became apparent in 2006. A programme to improve the execution of activities has been established in accordance with SKI's decision. SKI considers that the plant has developed in a positive direction but that there are further possibilities for improvement with regard to internal control. This is amongst other things concerns the areas internal auditing, independent safety review function, and working methods. SKI has had special supervision of the plant since 28 September, 2006. At the Oskarshamn plant work has been carried out to improve the organisation and routines in several areas. The plant has established routines which provide the basis to ensure that decisions are taken in a stringent manner. The quality assurance system has a clearer structure and there is a better defined division of work. Some measures remain however to be dealt with in 2008. The Ringhals plant has also worked with attitudes to routines and internal control. SKI considers that the measures have good prerequisites to provide a

  1. Development of digital plant protection system for Korean Next Generation Reactor

    International Nuclear Information System (INIS)

    Suk-Joon Park

    1998-01-01

    A Digital Plant Protection System (DPPS) for Korean Next Generation Reactor (KNGR) is being developed using the Programmable Logic Controller (PLC) technology. For the design verification, the development of the DPPS prototype is progressing at this time. The prototype hardware equipment is installed and software coding is started. DPPS software is being coded by strict software V and V activities and function block language that uses simple graphical symbols. By adopting the PLC technology, the design of DPPS is possible to take full advantages in areas such as automatic testing, simplified calibration, improved isolation between redundant channels, reduced internal and external wiring and increased plant availability. (author)

  2. An Extended Chemical Plant Environmental Protection Game on Addressing Uncertainties of Human Adversaries

    Science.gov (United States)

    Wang, Rongxiao; Chen, Feiran; Wang, Yiping; Qiu, Xiaogang

    2018-01-01

    Chemical production activities in industrial districts pose great threats to the surrounding atmospheric environment and human health. Therefore, developing appropriate and intelligent pollution controlling strategies for the management team to monitor chemical production processes is significantly essential in a chemical industrial district. The literature shows that playing a chemical plant environmental protection (CPEP) game can force the chemical plants to be more compliant with environmental protection authorities and reduce the potential risks of hazardous gas dispersion accidents. However, results of the current literature strictly rely on several perfect assumptions which rarely hold in real-world domains, especially when dealing with human adversaries. To address bounded rationality and limited observability in human cognition, the CPEP game is extended to generate robust schedules of inspection resources for inspection agencies. The present paper is innovative on the following contributions: (i) The CPEP model is extended by taking observation frequency and observation cost of adversaries into account, and thus better reflects the industrial reality; (ii) Uncertainties such as attackers with bounded rationality, attackers with limited observation and incomplete information (i.e., the attacker’s parameters) are integrated into the extended CPEP model; (iii) Learning curve theory is employed to determine the attacker’s observability in the game solver. Results in the case study imply that this work improves the decision-making process for environmental protection authorities in practical fields by bringing more rewards to the inspection agencies and by acquiring more compliance from chemical plants. PMID:29584679

  3. An Extended Chemical Plant Environmental Protection Game on Addressing Uncertainties of Human Adversaries.

    Science.gov (United States)

    Zhu, Zhengqiu; Chen, Bin; Qiu, Sihang; Wang, Rongxiao; Chen, Feiran; Wang, Yiping; Qiu, Xiaogang

    2018-03-27

    Chemical production activities in industrial districts pose great threats to the surrounding atmospheric environment and human health. Therefore, developing appropriate and intelligent pollution controlling strategies for the management team to monitor chemical production processes is significantly essential in a chemical industrial district. The literature shows that playing a chemical plant environmental protection (CPEP) game can force the chemical plants to be more compliant with environmental protection authorities and reduce the potential risks of hazardous gas dispersion accidents. However, results of the current literature strictly rely on several perfect assumptions which rarely hold in real-world domains, especially when dealing with human adversaries. To address bounded rationality and limited observability in human cognition, the CPEP game is extended to generate robust schedules of inspection resources for inspection agencies. The present paper is innovative on the following contributions: (i) The CPEP model is extended by taking observation frequency and observation cost of adversaries into account, and thus better reflects the industrial reality; (ii) Uncertainties such as attackers with bounded rationality, attackers with limited observation and incomplete information (i.e., the attacker's parameters) are integrated into the extended CPEP model; (iii) Learning curve theory is employed to determine the attacker's observability in the game solver. Results in the case study imply that this work improves the decision-making process for environmental protection authorities in practical fields by bringing more rewards to the inspection agencies and by acquiring more compliance from chemical plants.

  4. An Extended Chemical Plant Environmental Protection Game on Addressing Uncertainties of Human Adversaries

    Directory of Open Access Journals (Sweden)

    Zhengqiu Zhu

    2018-03-01

    Full Text Available Chemical production activities in industrial districts pose great threats to the surrounding atmospheric environment and human health. Therefore, developing appropriate and intelligent pollution controlling strategies for the management team to monitor chemical production processes is significantly essential in a chemical industrial district. The literature shows that playing a chemical plant environmental protection (CPEP game can force the chemical plants to be more compliant with environmental protection authorities and reduce the potential risks of hazardous gas dispersion accidents. However, results of the current literature strictly rely on several perfect assumptions which rarely hold in real-world domains, especially when dealing with human adversaries. To address bounded rationality and limited observability in human cognition, the CPEP game is extended to generate robust schedules of inspection resources for inspection agencies. The present paper is innovative on the following contributions: (i The CPEP model is extended by taking observation frequency and observation cost of adversaries into account, and thus better reflects the industrial reality; (ii Uncertainties such as attackers with bounded rationality, attackers with limited observation and incomplete information (i.e., the attacker’s parameters are integrated into the extended CPEP model; (iii Learning curve theory is employed to determine the attacker’s observability in the game solver. Results in the case study imply that this work improves the decision-making process for environmental protection authorities in practical fields by bringing more rewards to the inspection agencies and by acquiring more compliance from chemical plants.

  5. Phytochemicals of Brassicaceae in plant protection and human health--influences of climate, environment and agronomic practice.

    Science.gov (United States)

    Björkman, Maria; Klingen, Ingeborg; Birch, Andrew N E; Bones, Atle M; Bruce, Toby J A; Johansen, Tor J; Meadow, Richard; Mølmann, Jørgen; Seljåsen, Randi; Smart, Lesley E; Stewart, Derek

    2011-05-01

    In this review, we provide an overview of the role of glucosinolates and other phytochemical compounds present in the Brassicaceae in relation to plant protection and human health. Current knowledge of the factors that influence phytochemical content and profile in the Brassicaceae is also summarized and multi-factorial approaches are briefly discussed. Variation in agronomic conditions (plant species, cultivar, developmental stage, plant organ, plant competition, fertilization, pH), season, climatic factors, water availability, light (intensity, quality, duration) and CO(2) are known to significantly affect content and profile of phytochemicals. Phytochemicals such as the glucosinolates and leaf surface waxes play an important role in interactions with pests and pathogens. Factors that affect production of phytochemicals are important when designing plant protection strategies that exploit these compounds to minimize crop damage caused by plant pests and pathogens. Brassicaceous plants are consumed increasingly for possible health benefits, for example, glucosinolate-derived effects on degenerative diseases such as cancer, cardiovascular and neurodegenerative diseases. Thus, factors influencing phytochemical content and profile in the production of brassicaceous plants are worth considering both for plant and human health. Even though it is known that factors that influence phytochemical content and profile may interact, studies of plant compounds were, until recently, restricted by methods allowing only a reductionistic approach. It is now possible to design multi-factorial experiments that simulate their combined effects. This will provide important information to ecologists, plant breeders and agronomists. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Novel enabling technologies of gene isolation and plant transformation for improved crop protection

    Energy Technology Data Exchange (ETDEWEB)

    Torok, Tamas

    2013-02-04

    Meeting the needs of agricultural producers requires the continued development of improved transgenic crop protection products. The completed project focused on developing novel enabling technologies of gene discovery and plant transformation to facilitate the generation of such products.

  7. Safety and radiation protection in Indian nuclear power plants

    International Nuclear Information System (INIS)

    Ghadge, S.G.

    2008-01-01

    Full text: Nuclear energy, an important option for electricity generation is environment friendly, technologically proven, economically competitive and associated with the advantages of energy security and diversity. At present, India has an installed nuclear power generation capacity of 4120 M We with 6 more reactors are under construction/ commissioning at 4 sites. Nuclear power program, in India, as of now is primarily based on pressurized heavy water technology and these reactors are designed with safety features, such as, independent and diverse shut down systems, emergency core cooling system, double containment; pressure suppression pool etc. The principles of redundancy, diversity, fail-safe and passive systems are used in the design. The fundamental safety objective is to protect people and the environment from harmful effects of ionizing radiation. In this regard the prime responsibility for safety rests with the organization responsible for facilities and activities that give rise to radiation risks and is achieved by establishing and maintaining the necessary competence, providing adequate training and information, establishing procedures and arrangements to maintain safety under all conditions; verifying appropriate design and the adequate quality of facilities and activities and of their associated equipment; ensuring the safe control of all radioactive material that is used, produced, stored or transported, ensuring the safe control of all radioactive waste that is generated. 'Radiation Protection for Nuclear Facilities', issued by Atomic Energy Regulatory Board (the regulatory authority for NPPs in India) is the basic document for following radiation protection procedures in NPPs. Approved work procedures for all radiation jobs exist. Pre job briefing and post job analysis are carried out. Radiation protection is integrated with plant operation. Radiation levels indicate the performance of several systems. Several measures are adopted in design and

  8. Cathodic corrosion protection for the inside areas of metallic plants (KKS-I); Kathodischer Korrosionsschutz fuer die Innenflaechen von metallischen Anlagen (KKS-I)

    Energy Technology Data Exchange (ETDEWEB)

    Tenzer, Norbert [TZ-International Corrosion Consulting, Hagen (Germany)

    2012-07-01

    Cathodic corrosion protection for the inside areas of metallic plants (KKS-I) is a worldwide used technology in order to afford a safe protection of metallic plans against corrosion. This technology is used for plants in the treatment and storage of drinking water, for containers and reaction vessels in the chemical industry, for plants in the oil and gas industry as well as for containers and large-dimension pipelines containing seawater for the cooling of air liquefaction plants, power plants and seawater desalination plants, for examples. Furthermore, there exist further special applications for wastewater systems and biogas plants. The general description of the KKS-I shall supply the information to the operators of appropriate plants, that the cathodic corrosion protection also offers a wide range of applications for the protection of the inside areas of the plants against corrosion. Beside the previously mentioned standard areas of application there exist manifold further possibilities of application for metallic plants. It has to be emphasized that there are application possibilities not only for unalloyed or low alloy steels but also for stainless steels, aluminium, lead, copper, titanium and zinc. The regulation DIN EN 12499 firstly edited in 2003 contains the fundamentals, areas of application and specifications.

  9. Commonalty initiatives in US nuclear power plants to improve radiation protection culture and worker efficiency

    International Nuclear Information System (INIS)

    Wood, W.; Miller, D.

    2003-01-01

    Many US nuclear power plants have learned that common procedures, policies, instrumentation, tools and work practices achieve improvements to the radiation protection culture. Significant worker efficiency achievements are accomplished especially during refuelling outages. This paper discusses commonalty initiatives currently being implemented at many US Plants to address management challenges presented by deregulation of the US electric industry, reduction in the pool of outage contractors and aging of the experienced radiation worker population. The new INPO 2005 dose goals of 650 person-mSv/year for PWRs and 1200 person-mSv/yr for PWRs will require new approaches to radiation protection management to achieve these challenging goals by 2005. (authors)

  10. Analysis of interference on over-temperature protection value ΔT in nuclear power plant

    International Nuclear Information System (INIS)

    Chen Yongwei; Fu Jingqiang

    2015-01-01

    In nuclear power plant, the over-temperature protection value ΔT prevents nucleate from boiling and protects the fuel cladding. This paper focused on the fluctuation of ΔT, which is one of the common-mode failures. After sensitivity analysis and simulations of explanatory variables on over-temperature protection value, the sources and objects of the interference are located. And according to investigations on the fluctuation phenomena, the cable layout design defects are confirmed as the causes. The solutions were thus given and successfully verified by on-site implementation. (authors)

  11. Playing Chemical Plant Environmental Protection Games with Historical Monitoring Data.

    Science.gov (United States)

    Zhu, Zhengqiu; Chen, Bin; Reniers, Genserik; Zhang, Laobing; Qiu, Sihang; Qiu, Xiaogang

    2017-09-29

    The chemical industry is very important for the world economy and this industrial sector represents a substantial income source for developing countries. However, existing regulations on controlling atmospheric pollutants, and the enforcement of these regulations, often are insufficient in such countries. As a result, the deterioration of surrounding ecosystems and a quality decrease of the atmospheric environment can be observed. Previous works in this domain fail to generate executable and pragmatic solutions for inspection agencies due to practical challenges. In addressing these challenges, we introduce a so-called Chemical Plant Environment Protection Game (CPEP) to generate reasonable schedules of high-accuracy air quality monitoring stations (i.e., daily management plans) for inspection agencies. First, so-called Stackelberg Security Games (SSGs) in conjunction with source estimation methods are applied into this research. Second, high-accuracy air quality monitoring stations as well as gas sensor modules are modeled in the CPEP game. Third, simplified data analysis on the regularly discharging of chemical plants is utilized to construct the CPEP game. Finally, an illustrative case study is used to investigate the effectiveness of the CPEP game, and a realistic case study is conducted to illustrate how the models and algorithms being proposed in this paper, work in daily practice. Results show that playing a CPEP game can reduce operational costs of high-accuracy air quality monitoring stations. Moreover, evidence suggests that playing the game leads to more compliance from the chemical plants towards the inspection agencies. Therefore, the CPEP game is able to assist the environmental protection authorities in daily management work and reduce the potential risks of gaseous pollutants dispersion incidents.

  12. Playing Chemical Plant Environmental Protection Games with Historical Monitoring Data

    Science.gov (United States)

    Reniers, Genserik; Zhang, Laobing; Qiu, Xiaogang

    2017-01-01

    The chemical industry is very important for the world economy and this industrial sector represents a substantial income source for developing countries. However, existing regulations on controlling atmospheric pollutants, and the enforcement of these regulations, often are insufficient in such countries. As a result, the deterioration of surrounding ecosystems and a quality decrease of the atmospheric environment can be observed. Previous works in this domain fail to generate executable and pragmatic solutions for inspection agencies due to practical challenges. In addressing these challenges, we introduce a so-called Chemical Plant Environment Protection Game (CPEP) to generate reasonable schedules of high-accuracy air quality monitoring stations (i.e., daily management plans) for inspection agencies. First, so-called Stackelberg Security Games (SSGs) in conjunction with source estimation methods are applied into this research. Second, high-accuracy air quality monitoring stations as well as gas sensor modules are modeled in the CPEP game. Third, simplified data analysis on the regularly discharging of chemical plants is utilized to construct the CPEP game. Finally, an illustrative case study is used to investigate the effectiveness of the CPEP game, and a realistic case study is conducted to illustrate how the models and algorithms being proposed in this paper, work in daily practice. Results show that playing a CPEP game can reduce operational costs of high-accuracy air quality monitoring stations. Moreover, evidence suggests that playing the game leads to more compliance from the chemical plants towards the inspection agencies. Therefore, the CPEP game is able to assist the environmental protection authorities in daily management work and reduce the potential risks of gaseous pollutants dispersion incidents. PMID:28961188

  13. Playing Chemical Plant Environmental Protection Games with Historical Monitoring Data

    Directory of Open Access Journals (Sweden)

    Zhengqiu Zhu

    2017-09-01

    Full Text Available The chemical industry is very important for the world economy and this industrial sector represents a substantial income source for developing countries. However, existing regulations on controlling atmospheric pollutants, and the enforcement of these regulations, often are insufficient in such countries. As a result, the deterioration of surrounding ecosystems and a quality decrease of the atmospheric environment can be observed. Previous works in this domain fail to generate executable and pragmatic solutions for inspection agencies due to practical challenges. In addressing these challenges, we introduce a so-called Chemical Plant Environment Protection Game (CPEP to generate reasonable schedules of high-accuracy air quality monitoring stations (i.e., daily management plans for inspection agencies. First, so-called Stackelberg Security Games (SSGs in conjunction with source estimation methods are applied into this research. Second, high-accuracy air quality monitoring stations as well as gas sensor modules are modeled in the CPEP game. Third, simplified data analysis on the regularly discharging of chemical plants is utilized to construct the CPEP game. Finally, an illustrative case study is used to investigate the effectiveness of the CPEP game, and a realistic case study is conducted to illustrate how the models and algorithms being proposed in this paper, work in daily practice. Results show that playing a CPEP game can reduce operational costs of high-accuracy air quality monitoring stations. Moreover, evidence suggests that playing the game leads to more compliance from the chemical plants towards the inspection agencies. Therefore, the CPEP game is able to assist the environmental protection authorities in daily management work and reduce the potential risks of gaseous pollutants dispersion incidents.

  14. Do fungivores trigger the transfer of protective metabolites from host plants to arbuscular mycorrhizal hyphae?

    Science.gov (United States)

    Duhamel, Marie; Pel, Roel; Ooms, Astra; Bücking, Heike; Jansa, Jan; Ellers, Jacintha; van Straalen, Nico M; Wouda, Tjalf; Vandenkoornhuyse, Philippe; Kiers, E Toby

    2013-09-01

    A key objective in ecology is to understand how cooperative strategies evolve and are maintained in species networks. Here, we focus on the tri-trophic relationship between arbuscular mycorrhizal (AM) fungi, host plants, and fungivores to ask if host plants are able to protect their mutualistic mycorrhizal partners from being grazed. Specifically, we test whether secondary metabolites are transferred from hosts to fungal partners to increase their defense against fungivores. We grew Plantago lanceolata hosts with and without mycorrhizal inoculum, and in the presence or absence of fungivorous springtails. We then measured fungivore effects on host biomass and mycorrhizal abundance (using quantitative PCR) in roots and soil. We used high-performance liquid chromatography to measure host metabolites in roots, shoots, and hyphae, focusing on catalpol, aucubin, and verbascoside. Our most striking result was that the metabolite catalpol was consistently found in AM fungal hyphae in host plants exposed to fungivores. When fungivores were absent, catalpol was undetectable in hyphae. Our results highlight the potential for plant-mediated protection of the mycorrhizal hyphal network.

  15. Development and validation of advanced oxidation protective coatings for super critical steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, M.B.; Scheefer, M. [Alstom Power Ltd., Rugby (United Kingdom); Agueero, A. [Instituto Nacional de Tecnica Aerospacial (INTA) (Spain); Allcock, B. [Monitor Coatings Ltd. (United Kingdom); Norton, B. [Indestructible Paints Ltd. (United Kingdom); Tsipas, D.N. [Aristotle Univ. of Thessaloniki (Greece); Durham, R. [FZ Juelich (Germany); Xiang, Z. [Northumbria Univ. (United Kingdom)

    2006-07-01

    Increasing the efficiency of coal-fired power plant by increasing steam temperatures and pressures brings benefits in terms of cheaper electricity and reduced emissions, particularly CO{sub 2}. In recent years the development of advanced 9%Cr ferritic steels with improved creep strength has enabled power plant operation at temperatures in excess of 600 C, such that these materials are being exploited to construct a new generation of advanced coalfired plant. However, the move to higher temperatures and pressures creates an extremely hostile oxidising environment. To enable the full potential of the new steels to be achieved, it is vital that protective coatings are developed, validated under high temperature steam and applied to candidate components from the steam path. This paper reviews recent work conducted within the Framework V project ''Coatings for Supercritical Steam Cycles'' (SUPERCOAT) to develop and demonstrate advanced slurry and thermal spray coatings capable of providing steam oxidation protection at temperatures in excess of 620 C and up to 300 bar. The programme of work has demonstrated the feasibility of applying a number of candidate coatings to steam turbine power plant components and has generated long-term steam oxidation rate and failure data that underpin the design and application work packages needed to develop and establish this technology for new and retrofit plant. (orig.)

  16. Nanotechnology based surface treatments for corrosion protection and deposit control of power plant equipment. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-05-15

    Nanotechnology can provide possibilities for obtaining new valuable information regarding performance and corrosion protection in power plants. In general the desired performance of the contact surfaces is an easy-to-release effect. This is in order to prolong the time interval between cleaning periods or make the cleaning procedures easier and less expensive. Corrosion protection is also desired in order to extend the life time of various parts in the power plants and thus optimize the energy output and overall efficiency of the plant. Functional sol-gel coating based on nanotechnology is tested in a variety of conditions. Applications of functional sol-gel coatings were performed in the condenser and on seven air preheaters at Fynsvaerket, Odense, with corrosion protection as the main issue. Coatings with easy-to-clean effects were tested in the Flue Gas Desulphurization plant at Nordjyllandsvaerket, Aalborg, with the aim of reducing gipsum deposit. Thermo stabilized coatings were tested on tube bundles between in the passage from the 1st to 2end pass and on the wall between 1st and 2end pass at Amagervaerket, Copenhagen, and in the boiler at Haderslev CHP plant. The objective of this test were reducing deposits and increasing corrosion protection. The tested coatings were commercial available coatings and coatings developed in this project. Visual inspections have been performed of all applications except at Nordjyllandsvaerket. Corrosion assessment has been done at DTU - Mechanical Engineering. The results range from no difference between coated and uncoated areas to some improvements. At Amagervaerket the visual assessment showed in general a positive effect with a sol-gel hybrid system and a commercial system regarding removal of deposits. The visual assessment of the air preheaters at Fynsvaerket indicates reduced deposits on a sol-gel nanocomposite coated air preheater compared to an uncoated air preheater. (Author)

  17. 78 FR 16705 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Science.gov (United States)

    2013-03-18

    ...-FF08RSRC00] Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/ Fish Screen Facility Protection... removal and management of invasive plant species would occur at the Riparian Sanctuary. No active... impact statement and environmental impact report (EIS/EIR) for the Llano Seco Riparian Sanctuary Unit...

  18. 77 FR 26569 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Science.gov (United States)

    2012-05-04

    ...-FF08RSRC00] Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/ Fish Screen Facility Protection... would occur at the Riparian Sanctuary. No active restoration of native plants would occur. Maintenance... statement and environmental impact report (EIS/EIR) for the Llano Seco Riparian Sanctuary Unit Restoration...

  19. Application of fault tree methodology to modeling of the AP1000 plant digital reactor protection system

    International Nuclear Information System (INIS)

    Teolis, D.S.; Zarewczynski, S.A.; Detar, H.L.

    2012-01-01

    The reactor trip system (RTS) and engineered safety features actuation system (ESFAS) in nuclear power plants utilizes instrumentation and control (IC) to provide automatic protection against unsafe and improper reactor operation during steady-state and transient power operations. During normal operating conditions, various plant parameters are continuously monitored to assure that the plant is operating in a safe state. In response to deviations of these parameters from pre-determined set points, the protection system will initiate actions required to maintain the reactor in a safe state. These actions may include shutting down the reactor by opening the reactor trip breakers and actuation of safety equipment based on the situation. The RTS and ESFAS are represented in probabilistic risk assessments (PRAs) to reflect the impact of their contribution to core damage frequency (CDF). The reactor protection systems (RPS) in existing nuclear power plants are generally analog based and there is general consensus within the PRA community on fault tree modeling of these systems. In new plants, such as AP1000 plant, the RPS is based on digital technology. Digital systems are more complex combinations of hardware components and software. This combination of complex hardware and software can result in the presence of faults and failure modes unique to a digital RPS. The United States Nuclear Regulatory Commission (NRC) is currently performing research on the development of probabilistic models for digital systems for inclusion in PRAs; however, no consensus methodology exists at this time. Westinghouse is currently updating the AP1000 plant PRA to support initial operation of plants currently under construction in the United States. The digital RPS is modeled using fault tree methodology similar to that used for analog based systems. This paper presents high level descriptions of a typical analog based RPS and of the AP1000 plant digital RPS. Application of current fault

  20. 75 FR 56096 - Access to Confidential Business Information by Industrial Economics Incorporated

    Science.gov (United States)

    2010-09-15

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPPT-2003-0004; FRL-8845-1] Access to Confidential Business Information by Industrial Economics Incorporated AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY: EPA has authorized contractor, Industrial Economics Incorporated (IEI) of...

  1. Radiological respiratory protection in Angra-1 Nuclear Power Plant; Protecao respiratoria radiologica na Usina Nuclear de Angra

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Marcos A. do [Furnas Centrais Eletricas S.A., Angra dos Reis, RJ (Brazil). Central Nuclear de Angra I. Div. de Protecao Radiologica e Ambiental

    1996-07-01

    The present paper has the purpose to describe the actual situation of the Radiological respiratory Protection in Angra I Nuclear Power Plant, the difficulties found and the goals to achieve, in order of the radiological protection excellence. (author)

  2. Safeguards and security modeling for electrochemical plants

    International Nuclear Information System (INIS)

    Cipiti, B.B.; Duran, F.A.; Mendoza, L.A.; Parks, M.J.; Dominguez, D.; Le, T.D.

    2013-01-01

    Safeguards and security design for reprocessing plants can lead to excessive costs if not incorporated early in the design process. The design for electrochemical plants is somewhat uncertain since these plants have not been built at a commercial scale in the past. The Separation and Safeguards Performance Model (SSPM), developed at Sandia National Laboratories, has been used for safeguards design and evaluation for multiple reprocessing plant types. The SSPM includes the following capabilities: -) spent fuel source term library, -) mass tracking of elements 1-99 and bulk solid/liquids, -) tracking of heat load and activity, -) customisable measurement points, -) automated calculation of ID and error propagation, -) alarm conditions and statistical tests, and -) user-defined diversion scenarios. Materials accountancy and process monitoring data can provide more timely detection of material loss specifically to protect against the insider threat. While the SSPM is capable of determining detection probabilities and examining detection times for material loss scenarios, it does not model the operations or spatial effects for a plant design. The STAGE software was chosen to model the physical protection system. STAGE provides a framework to create end-to-end scalable force-on-force combat simulations. It allows for a complete 3D model of a facility to be designed along with the design of physical protection elements. This software, then, can be used to model operations and response for various material loss scenarios. The future integration of the SSPM model data with the STAGE software will provide a more complete analysis of diversion scenarios to assist plant designers

  3. Safeguards and security modeling for electrochemical plants

    Energy Technology Data Exchange (ETDEWEB)

    Cipiti, B.B.; Duran, F.A.; Mendoza, L.A.; Parks, M.J.; Dominguez, D.; Le, T.D. [Sandia National Laboratories, PO Box 5800 MS 0747, Albuquerque, NM 87185 (United States)

    2013-07-01

    Safeguards and security design for reprocessing plants can lead to excessive costs if not incorporated early in the design process. The design for electrochemical plants is somewhat uncertain since these plants have not been built at a commercial scale in the past. The Separation and Safeguards Performance Model (SSPM), developed at Sandia National Laboratories, has been used for safeguards design and evaluation for multiple reprocessing plant types. The SSPM includes the following capabilities: -) spent fuel source term library, -) mass tracking of elements 1-99 and bulk solid/liquids, -) tracking of heat load and activity, -) customisable measurement points, -) automated calculation of ID and error propagation, -) alarm conditions and statistical tests, and -) user-defined diversion scenarios. Materials accountancy and process monitoring data can provide more timely detection of material loss specifically to protect against the insider threat. While the SSPM is capable of determining detection probabilities and examining detection times for material loss scenarios, it does not model the operations or spatial effects for a plant design. The STAGE software was chosen to model the physical protection system. STAGE provides a framework to create end-to-end scalable force-on-force combat simulations. It allows for a complete 3D model of a facility to be designed along with the design of physical protection elements. This software, then, can be used to model operations and response for various material loss scenarios. The future integration of the SSPM model data with the STAGE software will provide a more complete analysis of diversion scenarios to assist plant designers.

  4. Safety Evaluation of Full Digital Plant Protection System of Shin-Kori 3 and 4 in Korea

    International Nuclear Information System (INIS)

    Koh, J. S.; Kim, D. I.; Jeong, C. H.; Park, H. S.; Ji, S. H.; Kang, Y. D.; Park, G. Y.

    2009-01-01

    Keeping pace with the emerging trend of digital computer technologies, KHNP has utilized full digital plant protection system into the design of I and C systems at SKN 3 and 4. This paper presents safety review activities and results related to digital plant protection systems during the licensing of construction permit for the Shin-Kori 3 and 4(SKN 3 and 4) in Korea. The major licensing issues regarding the digital systems were software quality and cyber security during planning stage, system integrity with fail-safe design, EMI equipment qualification of digital systems, FPGA qualification and communication independence between safety and non-safety System. This paper addresses our approach to evaluate full digital protection systems with revised safety review guidelines and the resulting discussion to resolve the licensing issues

  5. Lessons Learned in Protection of the Public for the Accident at the Fukushima Daiichi Nuclear Power Plant.

    Science.gov (United States)

    Callen, Jessica; Homma, Toshimitsu

    2017-06-01

    What insights can the accident at the Fukushima Daiichi nuclear power plant provide in the reality of decision making on actions to protect the public during a severe reactor and spent fuel pool emergency? In order to answer this question, and with the goal of limiting the consequences of any future emergencies at a nuclear power plant due to severe conditions, this paper presents the main actions taken in response to the emergency in the form of a timeline. The focus of this paper is those insights concerning the progression of an accident due to severe conditions at a light water reactor nuclear power plant that must be understood in order to protect the public.

  6. Computer aided radiation protection system at Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Ishida, J.; Saruta, J.; Yonezawa, R.

    1996-01-01

    Radiation control for workers and workforce has been carried out strictly and effectively taking into account ALARA principle at Tokai Reprocessing Plant (TRP) which has treated about 860 tons of irradiated fuels by now since 1977. The outline of radiation control method at TRP has already been described. This paper briefly describes our experiences and the capabilities of Radiological Information Management System (RIMS) for the safety operation of TRP, followed by radiation exposure control and activity discharge control as examples. By operating the RIMS, the conditions of workplace such as dose equivalent rate and air-contamination are easily and rapidly grasped to take prompt countermeasures for radiological protection, localization and elimination of contamination, and also the past experience data are properly applied to new radiological works to reduce exposures associated with routine and special repetitive maintenance operations at TRP. Finally, authors would like to emphasize that the form and system for radiological control of reprocessing plant has been established throughout our 15-year-experience at TRP. (author)

  7. Development of digital plant protection system for Korean Next Generation Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Suk-Joon [NSSS Engineering and Development Division, Korea Power Engineering Company, Taejon (Korea, Republic of)

    1998-10-01

    A Digital Plant Protection System (DPPS) for Korean Next Generation Reactor (KNGR) is being developed using the Programmable Logic Controller (PLC) technology. For the design verification, the development of the DPPS prototype is progressing at this time. The prototype hardware equipment is installed and software coding is started. DPPS software is being coded by strict software V and V activities and function block language that uses simple graphical symbols. By adopting the PLC technology, the design of DPPS is possible to take full advantages in areas such as automatic testing, simplified calibration, improved isolation between redundant channels, reduced internal and external wiring and increased plant availability. (author) 8 refs, 4 figs, 3 tabs

  8. Decentralized Coordination of Load Shedding and Plant Protection Considering High Share of RESs

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    variable using voltage drop data coordinated with plant protection scheme. A frequency anti stalling scheme is developed to interrupt more load feeders in case of frequency stall between consecutive set points. This time-based approach adjusts the time delay of the relay stages to disconnect the feeders...... with more voltage drop first, in order to bring the frequency back to the permissible range before the tolerable time period of plant protection relays is over. The load curtailment is stopped to avoid over LS, if the proposed algorithm recognizes that the frequency reaches the safe region in time based......This paper estimates the average Rate of Change of Frequency (ROCOF) following islanding and/or cascading event/s using inflection points of frequency profile. Moreover, a frequency collapse barrier scheme is set up by tuning the frequency set points of Load Shedding (LS) relays as a dynamic...

  9. Safeguarding aspects of large-scale commercial reprocessing plants

    International Nuclear Information System (INIS)

    1979-03-01

    The paper points out that several solutions to the problems of safeguarding large-scale plants have been put forward: (1) Increased measurement accuracy. This does not remove the problem of timely detection. (2) Continuous in-process measurement. As yet unproven and likely to be costly. (3) More extensive use of containment and surveillance. The latter appears to be feasible but requires the incorporation of safeguards into plant design and sufficient redundancy to protect the operators interests. The advantages of altering the emphasis of safeguards philosophy from quantitative goals to the analysis of diversion strategies should be considered

  10. IRSN's Position on Safety and Radiation Protection at Nuclear Power Plants in France, 2012

    International Nuclear Information System (INIS)

    2014-01-01

    After working a year to consolidate the data, the annual report on the radiation protection and safety of nuclear power plants in France gives the IRSN's independent point of view on all progress and problems concerning safety and radiation protection encountered in the French nuclear power plant fleet in 2012. The first part of the report presents the main trends that emerge from IRSN's overall assessment of the radiation protection and safety performance of currently operating nuclear power plants for the year 2012. The year 2012 has witnessed an increase in the total number of significant events. However, IRSN notes the absence in 2012 of incidents with a potentially significant impact on nuclear power plant safety, the surrounding environment or nearby communities in a context of large-scale personnel renewal. This increase can mainly be explained by EDF's implementation of an improved nonconformance detection and handling procedure which led to the identification, in 2012, of various non-conformances presumably present for several years but previously undetected. With regard to radiation protection, IRSN notes that the effective dose received by the majority of exposed workers over a period of 12 consecutive months is below the annual public radiation dose limit. Faults may occur with nuclear power plant equipment or reactor monitoring systems. Given the standardisation of EDF nuclear power plant reactors, such faults may affect an entire reactor series or even the entire reactor fleet. A few examples deemed particularly significant by IRSN are presented in the second part of this report. French nuclear reactors are subject to modifications throughout their operating lives, particularly with a view to ensuring continuous safety improvement, this is the subject of the third part of the report. Most of these modifications are the result of studies conducted within the framework of ten-yearly safety reviews, leading to the definition and

  11. Weed control by direct injection of plant protection products according to specific situations

    Directory of Open Access Journals (Sweden)

    Krebs, Mathias

    2016-02-01

    Full Text Available Precision Farming in agriculture allows a site-specific management of the crop. The aim of plant protection is to apply plant protection products (PPP according to the site specific requirements on the field. Within the context of a research program to promote innovation, a sprayer with direct injection of plant protection products was developed. The direct injection offers site specific spraying of different individual PPP in a single pass. The sprayer prototype is equipped with a special spray boom combining three nozzle lines. In order to prevent delay times, the nozzle lines are preloaded before spraying. First results for weed control from test stand measurements and field trials showed that the injection pumps work with high accuracy. The prototype can be used without delay times site specific with up to three different herbicides. Field trials for site-specific weed control in winter wheat demonstrate the applicability of the system under practical conditions. By treatment of subareas herbicides and therefore costs could be saved. A reduction in yield compared with the conventionally treated field areas could not be ascertained. Also an efficacy reduction through washout of active ingredient from target surfaces due to simultaneous use of all three nozzle lines with up to 1050 l/ha application rate could not be detected. At high water spray rates, the efficacy effect occurs delayed. Overall, the newly developed direct injection system proved fieldabillity during the first tests. So weed control can be carried out situation-responsive, which can save herbicides and environmental impacts are reduced.

  12. Refurbishing the reactor protection systems of VVER-440/230 and VVER-1000/320 nuclear power plants with exclusively digital IandC systems

    International Nuclear Information System (INIS)

    Martin, M.

    1997-01-01

    The refurbishment of reactor protection systems of nuclear power plants is based on two sets of requirements: engineering aspects such as performance, qualification and licensing, as well as interfaces to other systems; and cost-benefit relationships, ease of service and maintenance as well as installation during scheduled outages. A number of WWER-440 and WWER-1000 nuclear plants have announced their intention to refurbish their protection systems. Since 1994, these plants have been placing orders with Siemens for new protection systems, including the neutron flux monitoring system utilizing the advanced system TELEPERM XS. This exclusively digital IandC system provides an excellent foundation for the remaining plant service life

  13. Radiation Protection and Radioactive Waste Management in the Operation of Nuclear Power Plants. Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2010-01-01

    The purpose of this Safety Guide is to provide recommendations to the regulatory body, focused on the operational aspects of radiation protection and radioactive waste management in nuclear power plants, and on how to ensure the fulfilment of the requirements established in the relevant Safety Requirements publications. It will also be useful for senior managers in licensee or contractor organizations who are responsible for establishing and managing programmes for radiation protection and for the management of radioactive waste. This Safety Guide gives general recommendations for the development of radiation protection programmes at nuclear power plants. The issues are then elaborated by defining the main elements of a radiation protection programme. Particular attention is paid to area classification, workplace monitoring and supervision, application of the principle of optimization of protection (also termed the 'as low as reasonably achievable' (ALARA) principle), and facilities and equipment. This Safety Guide covers all the safety related aspects of a programme for the management of radioactive waste at a nuclear power plant. Emphasis is placed on the minimization of waste in terms of both activity and volume. The various steps in predisposal waste management are covered, namely processing (pretreatment, treatment and conditioning), storage and transport. Releases of effluents, the application of authorized limits and reference levels are discussed, together with the main elements of an environmental monitoring programme

  14. Effect of bacterial contamination on the incorporation of radioactive phosphate in plant r-RNA

    Energy Technology Data Exchange (ETDEWEB)

    Koleva, S; Khanymova, T; Marinova, E; Varadinova, S

    1974-01-01

    It is ascertained that the amount of bacterial colonies in root tips of maize seedlings (Wisconsin 641 AA) constitutes approximately 4.5x10/sup 7/ per gram of fresh weight, 90% of the bacterial colonies being various pseudomonas. In the case when plant RNA is labelled with /sup 32/P, the bacteria take up a large amount of phosphate. Owing to this, the RNA isolated from the root tips and fractionated in agar gel, in addition to 25S and 18S r-RNA of the plant cell cytoplasma contains also 23S and 16S of the bacterial r-RNA. Chloramphenicol at a concentration of 50/cm/sup 3/ does not suppress the incorporation of /sup 32/P by the bacteria. The pseudomonas strains isolated are almost insensitive to chloramphenicol and a number of other antibiotics, such as penicyllin, erythromycin, neomycin and oxacylin. This results, as well as the results, obtained by other researchers, indicate that antibiotics do not suppress effectively the action of bacterial contamination if plant RNA is labelled. Furtheremore, some of them, as streptomycin, for instance, if employed at higher concentrations inhibit the growth of the plant cell. Of all asceptic agents (hypochlorite, ethanol, sulphuric acid, etc.), used for surface sterilization, best results in the elimination of bacterial infection on maize seeds have been obtained with 0.1% HgCl/sub 2/ after treatment for 2 min. In spite of the elimination of the bacterial contamination with HgCl/sub 2/,the RNA from the elongated cells, labelled with /sup 32/P for an hour, is distributed into four fractions in the agar gel conversely to the RNA isolated from dividing cells, where only the two 25S and 18S fractions of plant cytoplasmic r-RNA are observed. An assumption is made that the two more fast-moving r-RNA fractions, as compared with 25S and 18S of plant r-RNA, isolated from elongating cells, originate from subcellular organelles, since the mitochondria and the proplstids are fully differentiated during the phase of the elongation of the

  15. SRP groundwater protection implementation plan. Draft

    International Nuclear Information System (INIS)

    1983-01-01

    Maintaining the quality of the Savannah River Plant environment and protecting offsite areas from the impact of facility operations were recognized as important goals prior to site startup. Monitoring programs were initiated in the Savannah River and on the site to establish baseline conditions before facility operations began. These programs by plant personnel and other scientific groups have been significantly expanded during the 30 years of operation. Monitoring results cover airborne effluents and surface and subsurface waters. Analyses include both radioactive and nonradioactive species. These programs have established the Savannah River site as one of the most extensively monitored locations in the world. These activities are the foundation of a broad based environmental program which has consistently demonstrated the negligible environmental impact of the site's operations on the general public. In addition to the extensive monitoring program, many advances in effluent treatment technology have been incorporated in plant facilities. There is no immediate threat of any kind to the on- or offsite population

  16. Evidence for a universal pathway of abscisic acid biosynthesis in higher plants from 18O incorporation patterns

    International Nuclear Information System (INIS)

    Zeevaart, J.A.D.; Heath, T.G.; Gage, D.A.

    1989-01-01

    Previous labeling studies of abscisic acid (ABA) with 18 O 2 have been mainly conducted with water-stressed leaves. In this study, 18 O incorporation into ABA of stressed leaves of various species was compared with 18 O labeling of ABA of turgid leaves and of fruit tissue in different stages of ripening. In stressed leaves of all six species investigated, avocado (Persea americana), barley (Hordeum vulgare), bean (Phaseolus vulgaris), cocklebur (Xanthium strumarium), spinach (Spinacia oleracea), and tobacco (Nicotiana tabacum), 18 O was most abundant in the carboxyl group, whereas incorporation of a second and third 18 O in the oxygen atoms on the ring of ABA was much less prominent after 24 h in 18 O 2 . ABA from turgid bean leaves showed significant 18 O incorporation, again with highest 18 O enrichment in the carboxyl group. On the basis of 18 O-labeling patterns observed in ABA from different tissues it is concluded that, despite variations in precusor pool sizes and intermediate turnover rates, there is a universal pathway of ABA biosynthesis in higher plants which involves cleavage of a larger precursor molecule, presumably an oxygenated carotenoid

  17. Nitrate Protects Cucumber Plants Against Fusarium oxysporum by Regulating Citrate Exudation.

    Science.gov (United States)

    Wang, Min; Sun, Yuming; Gu, Zechen; Wang, Ruirui; Sun, Guomei; Zhu, Chen; Guo, Shiwei; Shen, Qirong

    2016-09-01

    Fusarium wilt causes severe yield losses in cash crops. Nitrogen plays a critical role in the management of plant disease; however, the regulating mechanism is poorly understood. Using biochemical, physiological, bioinformatic and transcriptome approaches, we analyzed how nitrogen forms regulate the interactions between cucumber plants and Fusarium oxysporum f. sp. cucumerinum (FOC). Nitrate significantly suppressed Fusarium wilt compared with ammonium in both pot and hydroponic experiments. Fewer FOC colonized the roots and stems under nitrate compared with ammonium supply. Cucumber grown with nitrate accumulated less fusaric acid (FA) after FOC infection and exhibited increased tolerance to chemical FA by decreasing FA absorption and transportation in shoots. A lower citrate concentration was observed in nitrate-grown cucumbers, which was associated with lower MATE (multidrug and toxin compound extrusion) family gene and citrate synthase (CS) gene expression, as well as lower CS activity. Citrate enhanced FOC spore germination and infection, and increased disease incidence and the FOC population in ammonium-treated plants. Our study provides evidence that nitrate protects cucumber plants against F. oxysporum by decreasing root citrate exudation and FOC infection. Citrate exudation is essential for regulating disease development of Fusarium wilt in cucumber plants. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Aspects of the incorporation of spatial data into radioecological and restoration analysis

    International Nuclear Information System (INIS)

    Beresford, N.A.; Wright, S.M.; Howard, B.J.; Crout, N.M.J.; Arkhipov, A.; Voigt, G.

    2002-01-01

    In the last decade geographical information systems have been increasingly used to incorporate spatial data into radioecological analysis. This has allowed the development of models with spatially variable outputs. Two main approaches have been adopted in the development of spatial models. Empirical Tag based models applied across a range of spatial scales utilize underlying soil type maps and readily available radioecological data. Soil processes can also be modelled to allow the dynamic prediction of radionuclide soil to plant transfer. We discuss a dynamic semi-mechanistic radiocaesium soil to plant-transfer model, which utilizes readily available spatially variable soil parameters. Both approaches allow the identification of areas that may be vulnerable to radionuclide deposition, therefore enabling the targeting of intervention measures. Improved estimates of radionuclide fluxes and ingestion doses can be achieved by incorporating spatially varying inputs such as agricultural production and dietary habits in to these models. In this paper, aspects of such models, including data requirements, implementation and outputs are discussed and critically evaluated. The relative merits and disadvantages of the two spatial model approaches adopted within radioecology are discussed. We consider the usefulness of such models to aid decision-makers and access the requirements and potential of further application within radiological protection. (author)

  19. Topical radiation protection questions of use of agricultural land in the environs of nuclear power plants

    International Nuclear Information System (INIS)

    Carach, J.; Csupka, S.; Petrasova, M.

    1982-01-01

    A survey is presented of the problems of the use of agricultural land in the environs of nuclear power plants. The analysis of emission activity in nuclear power plants presently under construction shows that for normal operation no precautions are necessary. For accidents, specific health protection measures are planned. (author)

  20. Regulatory aspects of radiation protection in Indian nuclear plants

    International Nuclear Information System (INIS)

    Chander, Vipin; Pawar, S.K.; Duraisamy, S.

    2012-01-01

    Atomic Energy Act of 1962 covers the radiation safety aspects in the development, control and use of atomic energy. To carry out certain regulatory and safety functions under this act, Atomic Energy Regulatory Board (AERB) was constituted in November 15, 1983. Operating Nuclear Power Plants (NPPs) account for about 60% of occupational collective dose and about 65% of the number of radiation workers in the nuclear fuel cycle facilities. Therefore radiation protection aspects in NPPs are of prime importance. In 1970s and 1980s the high radiation exposures in NPPs was an issue with TAPS-1 and 2 reaching annual collective dose of 50 Person-Sv. In response to this, AERB constituted an expert committee to investigate the possibility of reducing collective doses in NPPs in 1988. Subsequently the recommendations of this committee were implemented in all NPPs. In 1990, International Commission on Radiological Protection (ICRP) recommended a downward revision of occupational dose limit to 20 mSv/yr from the earlier limit of 50 mSv/yr. Regulatory body endorsed these recommendations and gradually brought down the annual dose limits from 40 mSv in 1991 to 30 mSv in 1994 with the limit of 100 mSv averaged over a five year period in line with ICRP recommendations. Over the years, the regulatory body has put in place a sound regulatory frame work and mechanism to ensure adequate protection of occupational workers, members of public and environment due to operation of NPPs. Vast experiences in the field of radiation protection vis-à-vis stringent regulatory requirements such as review of exposure cases and special regulatory inspections during Biennial Shut Down (BSD) has helped in downward trends in occupational and public doses. This paper highlights the role of regulatory body in controlling the radiation doses to both occupational workers and members of public in the NPPs through a three-tier review system. The regulatory oversight, inspections and reviews has resulted in

  1. Carbon steel protection in G.S. [Girldler sulphide] plants: Pt. 8

    International Nuclear Information System (INIS)

    Lires, Osvaldo; Delfino, Cristina; Rojo, Enrique.

    1990-01-01

    In order to protect carbon steel of towers and piping of a GS experimental heavy water plant against corrosion produced by the action of aqueous solutions of hydrogen sulphide, a method, elsewhere published, was developed. Carbon steel exposed to saturated aqueous solutions of hydrogen sulphide forms iron sulphide scales. In oxygen free solutions, evolution of corrosion follows the sequence mackinawate → cubic ferrous sulphide → troilite → pyrrotite → pyrite. Scales formed by pyrrotite and pyrite are the most protective layers (these are obtained at 130 deg C, 2 MPa for a period of 14 days). Pyrite formation is favoured by an oxidizing agent presence that allows the oxidation of sulphur ions to disulphur ions. Elemental sulphur or oxygen were used as oxidating agents. Variation and operational parameters such as concentration, temperature, pH, aggregate time, etc. were studied. Though little improvement on protective scales quality was observed, results do not justify operational troubles and the additional costs and effort involved. (Author)

  2. Testing methodology of embedded software in digital plant protection system

    International Nuclear Information System (INIS)

    Seong, Ah Young; Choi, Bong Joo; Lee, Na Young; Hwang, Il Soon

    2001-01-01

    It is necessary to assure the reliability of software in order to digitalize RPS(Reactor Protection System). Since RPS causes fatal damage on accidental cases, it is classified as Safety 1E class. Therefore we propose the effective testing methodology to assure the reliability of embedded software in the DPPS(Digital Plant Protection System). To test the embedded software effectively in DPPS, our methodology consists of two steps. The first is the re-engineering step that extracts classes from structural source program, and the second is the level of testing step which is composed of unit testing, Integration Testing and System Testing. On each testing step we test the embedded software with selected test cases after the test item identification step. If we use this testing methodology, we can test the embedded software effectively by reducing the cost and the time

  3. Agroecological Importance of the Protective Forest Plantings in Lower Volga Region

    Directory of Open Access Journals (Sweden)

    Ivantsova Elena Anatolyevna

    2014-12-01

    Full Text Available The positive role of protective forest plantings in maintaining the stability of biotic communities and ensuring stabilization of a phytosanitary situation in the agricultural and woodland landscape of steppe and semiarid zones of Lower Volga region is established. The analysis of long-term data testifies that in general, the number of a harmful complex on fields of winter wheat (Triticum and brown mustard (Brassica juncea in the system of forest strips is lower than in opened agrocoenosis in average by 20,6 % and 16,2 %, respectively. The regularities of distribution of harmful and useful insects in corn and mustard agrocoenosis are noted. The obtained data on distribution of harmful insects and their concentration in a forested field gives the grounds to include regional processings of agrocoenosis of agricultural and woodland landscape in the system of protective measures. It is established that the existence of fields afforestation in Volgograd region creates the favorable conditions for development and accumulation of entomophages in fields. It leads to restriction of mass reproduction of harmful insects and to the decrease in their injuriousness. The essential distinctions in distribution and development of diseases in the agrocoenosis protected by forest plantings and the treeless fields are revealed. The maximal values of development of a complex of diseases on winter wheat are observed in zones, adjacent to forest strips (I and III, minimum – in the middle of a field. The estimated values of development of diseases in forested field is less, and in certain cases it slightly differs from the data obtained in a treeless field.

  4. Intercropping System for Protection the Potato Plant from Insect Infestation

    Directory of Open Access Journals (Sweden)

    Aziza Sharaby

    2015-06-01

    Full Text Available The use of intercropping system provides an option for insect control for organic farmers that are limited in their chemical use. Additionally, intercropping systems can be attractive to conventional growers as a cost-effective insect control solution. A study was carried out for two seasons 2011-2012 and 2012-2013 to evaluate the effect of intercropping of potato (Solanum tuberosum L. with onion (Allium cepa L. on whitefly (Bemicia tabasi Gennadius and aphids’ Myzus persicae Sulz. and Aphis gossypii Glover infestation in potato fields. Results indicated that intercropping significantly reduced potato plant infestation with whitefly by 42.7, 51.3% while it was 62.69% reduction with aphids during the two successive winter seasons than when potato plants were cultivated alone. Therefore, intercropping could be recommended as a protection method of reducing pest population in the fields.

  5. Photosynthetic incorporation of 14C by Stevia rebaudiana

    International Nuclear Information System (INIS)

    Ferraresi, M. de L.; Ferraresi Filho, O.; Bracht, A.

    1985-01-01

    The photosynthetic incorporation of 14 by Stevia rebaudiana specimens was investigated. The 14 C incorporation, when the isotope was furnished to the plant in form of 14 CO 2 , was rapid. After 24 hours, the radioactivity has been incorporated into a great number of compounds including pigments, terpenes, glucose, cellulose and also stevioside and its derivatives. (M.A.C.) [pt

  6. Hexanoic acid protects tomato plants against Botrytis cinerea by priming defence responses and reducing oxidative stress.

    Science.gov (United States)

    Finiti, Ivan; de la O Leyva, María; Vicedo, Begonya; Gómez-Pastor, Rocío; López-Cruz, Jaime; García-Agustín, Pilar; Real, Maria Dolores; González-Bosch, Carmen

    2014-08-01

    Treatment with the resistance priming inducer hexanoic acid (Hx) protects tomato plants from Botrytis cinerea by activating defence responses. To investigate the molecular mechanisms underlying hexanoic acid-induced resistance (Hx-IR), we compared the expression profiles of three different conditions: Botrytis-infected plants (Inf), Hx-treated plants (Hx) and Hx-treated + infected plants (Hx+Inf). The microarray analysis at 24 h post-inoculation showed that Hx and Hx+Inf plants exhibited the differential expression and priming of many Botrytis-induced genes. Interestingly, we found that the activation by Hx of other genes was not altered by the fungus at this time point. These genes may be considered to be specific targets of the Hx priming effect and may help to elucidate its mechanisms of action. It is noteworthy that, in Hx and Hx+Inf plants, there was up-regulation of proteinase inhibitor genes, DNA-binding factors, enzymes involved in plant hormone signalling and synthesis, and, remarkably, the genes involved in oxidative stress. Given the relevance of the oxidative burst occurring in plant-pathogen interactions, the effect of Hx on this process was studied in depth. We showed by specific staining that reactive oxygen species (ROS) accumulation in Hx+Inf plants was reduced and more restricted around infection sites. In addition, these plants showed higher ratios of reduced to oxidized glutathione and ascorbate, and normal levels of antioxidant activities. The results obtained indicate that Hx protects tomato plants from B. cinerea by regulating and priming Botrytis-specific and non-specific genes, preventing the harmful effects of oxidative stress produced by infection. © 2013 BSPP AND JOHN WILEY & SONS LTD.

  7. Vital area identification software VIP for the physical protection of nuclear power plants

    International Nuclear Information System (INIS)

    Jung, Woo Sik; Park, Chang Kue; Yang, Joon Eon

    2004-01-01

    There are two major factors to be considered for the physical protection of nuclear power plants. They are a design basis threat (DBT) and the vital area identification (VAI). The DBT has been considered as 'the maximum credible threat.' The vital area is defined as 'an area inside a protected area containing equipment, systems or devices, or nuclear materials, the sabotage of which could directly or indirectly lead to unacceptable radiological consequences.' For the VAI of nuclear power plants, a software VIP (Vital area Identification Package based on PSA method) is being developed. The VIP is based on the current probabilistic safety assessment (PSA) techniques. The PSA method, including internal as well as external events, is known as the most complete and consistent method for identifying various accident sequences that might result in a core melt and radioactive material release to the environment. Thus, the VIP employs a fault tree analysis method in the PSA and utilizes the PSA results

  8. Fire protection for nuclear power plants. Part 1. Fundamental approaches. Version 6/99

    International Nuclear Information System (INIS)

    1999-06-01

    The KTA nuclear safety code sets out the fundamental approaches and principles for the prevention of fires in nuclear power plants, addressing aspects such as initiation, spreading, and effects of a fire: (a) Fire load and ignition sources, (b) structural and plant engineering conditions, (c) ways and means relating to fire call and fire fighting. Relevant technical and organisational measures are defined. Scope and quality of fire prevention measures to be taken, as well the relevant in-service inspection activities are determined according to the protective goals pursued in each case. (orig./CB) [de

  9. Lightning protection design of nuclear power plants. KTA safety code, version 6/99

    International Nuclear Information System (INIS)

    1999-06-01

    This KTA safety code does not cover calculation methods for determination of lightning-induced voltage inputs to control room systems within the reactor building, as the literature presents a variety of applicable methods, which however cannot be directly applied to any power plant, due to the great diversity of geometries of the electrical systems and control room systems in nuclear power plants. Compliance with the design requirements of this safety code for shielding of buildings, and installation and shielding of cables, can be considered to offer the appropriate protection. (orig./CB) [de

  10. Technical methods for a risk-informed, performance-based fire protection program at nuclear power plants

    International Nuclear Information System (INIS)

    Dey, M.K.

    1998-01-01

    This paper presents a technical review and examination of technical methods that are available for developing a risk-informed, performance-based fire protection program at a nuclear plant. The technical methods include ''engineering tools'' for examining the fire dynamics of fire protection problems, reliability techniques for establishing an optimal fire protection surveillance program, fire computer codes for analyzing important fire protection safety parameters, and risk-informed approaches that can range from drawing qualitative insights from risk information to quantifying the risk impact of alternative fire protection approaches. Based on this technical review and examination, it is concluded that methods for modeling fires, and reliability and fire PRA analyses are currently available to support the initial implementation of simple risk-informed, performance-based approaches in fire protection programs. (author)

  11. Technical methods for a risk-informed, performance-based fire protection program at nuclear power plants

    International Nuclear Information System (INIS)

    Dey, M.K.

    2000-01-01

    This paper presents a technical review and examination of technical methods that are available for developing a risk-informed, performance-based fire protection program at a nuclear plant. The technical methods include 'engineering tools' for examining the fire dynamics of fire protection problems, reliability techniques for establishing an optimal fire protection surveillance program, fire computer codes for analyzing important fire protection safety parameters, and risk-informed approaches that can range from drawing qualitative insights from risk information to quantifying the risk impact of alternative fire protection approaches. Based on this technical review and examination, it is concluded that methods for modeling fires, and reliability and fire probabilistic risk analyses (PRA) are currently available to support the initial implementation of simple risk-informed, performance-based approaches in fire protection programs. (orig.) [de

  12. Heat inactivation of leaf phosphoenolpyruvate carboxylase: Protection by aspartate and malate in C4 plants.

    Science.gov (United States)

    Rathnam, C K

    1978-01-01

    The activity of phosphoenolpyruvate (PEP) carboxylase EC 4.1.1.31 in leaf extracts of Eleusine indica L. Gaertn., a C4 plant, exhibited a temperature optimum of 35-37° C with a complete loss of activity at 50° C. However, the enzyme was protected effectively from heat inactivation up to 55° C by L-aspartate. Activation energies (Ea) for the enzyme in the presence of aspartate were 2.5 times lower than that of the control enzyme. Arrhenius plots of PEP carboxylase activity (±aspartate) showed a break in the slope around 17-20° C with a 3-fold increase in the Ea below the break. The discontinuity in the slopes was abolished by treating the enzyme extracts with Triton X-100, suggesting that PEP carboxylase in C4 plants is associated with lipid and may be a membrane bound enzyme. Depending upon the species, the major C4 acid formed during photosynthesis (malate or aspartate) was found to be more protective than the minor C4 acid against the heat inactivation of their PEP carboxylase. Oxaloacetate, the reaction product, was less effective compared to malate or aspartate. Several allosteric inhibitors of PEP carboxylase were found to be moderately to highly effective in protecting the C4 enzyme while its activators showed no significant effect. PEP carboxylase from C3 species was not protected from thermal inactivation by the C4 acids. The physiological significance of these results is discussed in relation to the high temperature tolerance of C4 plants.

  13. Radiation protection - Revision of French radiation protection regulations (1988)

    International Nuclear Information System (INIS)

    Mayoux, J.C.

    1989-01-01

    This article analyses the recent amendments to the 1966 and 1975 Decrees on general radiation protection principles and radiation protection of workers in large nuclear installations respectively and also describes national radiation protection law. In particular, the amendments incorporate the revised EURATOM basic radiation protection standards and the new international units (sievert and becquerel replace rem and curie) in the Decrees. (NEA) [fr

  14. A relay rack for a control and protection system for nuclear reactors

    International Nuclear Information System (INIS)

    Miyata, Yasuyuki; Oda, Noriaki; Akiyama, Toyoshi

    1975-01-01

    It is obvious that all the equipment in the various systems that constitute a nuclear power plant must exhibit the highest levels of reliability, but the reactor control and protection system is of vital importance, and thus it requires a particularly thorough approach, incorporating redundancy, independence and separation. The paper describes the functions, construction and specifications of the relay rack - one of the most important items of equipment for reactor control and protection in a generating facility using a pressurized-water reactor - and it gives details of the extent to which these three requirements are satisfied. (author)

  15. Incorporating organizational factors into probabilistic safety assessment of nuclear power plants through canonical probabilistic models

    Energy Technology Data Exchange (ETDEWEB)

    Galan, S.F. [Dpto. de Inteligencia Artificial, E.T.S.I. Informatica (UNED), Juan del Rosal, 16, 28040 Madrid (Spain)]. E-mail: seve@dia.uned.es; Mosleh, A. [2100A Marie Mount Hall, Materials and Nuclear Engineering Department, University of Maryland, College Park, MD 20742 (United States)]. E-mail: mosleh@umd.edu; Izquierdo, J.M. [Area de Modelado y Simulacion, Consejo de Seguridad Nuclear, Justo Dorado, 11, 28040 Madrid (Spain)]. E-mail: jmir@csn.es

    2007-08-15

    The {omega}-factor approach is a method that explicitly incorporates organizational factors into Probabilistic safety assessment of nuclear power plants. Bayesian networks (BNs) are the underlying formalism used in this approach. They have a structural part formed by a graph whose nodes represent organizational variables, and a parametric part that consists of conditional probabilities, each of them quantifying organizational influences between one variable and its parents in the graph. The aim of this paper is twofold. First, we discuss some important limitations of current procedures in the {omega}-factor approach for either assessing conditional probabilities from experts or estimating them from data. We illustrate the discussion with an example that uses data from Licensee Events Reports of nuclear power plants for the estimation task. Second, we introduce significant improvements in the way BNs for the {omega}-factor approach can be constructed, so that parameter acquisition becomes easier and more intuitive. The improvements are based on the use of noisy-OR gates as model of multicausal interaction between each BN node and its parents.

  16. Incorporating organizational factors into probabilistic safety assessment of nuclear power plants through canonical probabilistic models

    International Nuclear Information System (INIS)

    Galan, S.F.; Mosleh, A.; Izquierdo, J.M.

    2007-01-01

    The ω-factor approach is a method that explicitly incorporates organizational factors into Probabilistic safety assessment of nuclear power plants. Bayesian networks (BNs) are the underlying formalism used in this approach. They have a structural part formed by a graph whose nodes represent organizational variables, and a parametric part that consists of conditional probabilities, each of them quantifying organizational influences between one variable and its parents in the graph. The aim of this paper is twofold. First, we discuss some important limitations of current procedures in the ω-factor approach for either assessing conditional probabilities from experts or estimating them from data. We illustrate the discussion with an example that uses data from Licensee Events Reports of nuclear power plants for the estimation task. Second, we introduce significant improvements in the way BNs for the ω-factor approach can be constructed, so that parameter acquisition becomes easier and more intuitive. The improvements are based on the use of noisy-OR gates as model of multicausal interaction between each BN node and its parents

  17. Using Patents to Protect Traditional Knowledge on the Medicinal Uses of Plants in South Africa

    Directory of Open Access Journals (Sweden)

    Emeka Polycarp Amechi

    2015-06-01

    Full Text Available The movement towards the protection of traditional knowledge particularly on the medicinal uses of plants (TKMUP in South Africa reflects a global albeit belated interest in the protection of traditional knowledge associated with biological resources. Hence, it was not surprising South Africa like most developing nation, sought in response to instances of the misappropriation of its TKMUP and other TK associated with its biological resources, to provide a measure of protection for such knowledge using the intellectual property (IP system. This is evident in the adoption of the Policy Framework for the Protection of Indigenous Knowledge through the Intellectual Property System in 2008 which identified patent as one of the major IP tools in the protection of the TK. The Policy Framework represents a paradigmatic shift from South Africa’s earlier sceptical and dialectical approach to, and experience with the IP system in context of TK. This paper therefore examines the benefits and challenges involved in using the patent system in the protection of TK particularly those relating to the medicinal uses of plants (TKMUP. Such examination became necessary as South Africa’s natural capital of biological diversity, together with its wealth of indigenous TK, has been recognised as an important resource base for promoting economic growth through biological innovations under the recently adopted Bio-economy Strategy. It finds that patents offer a great potential in not only protecting TKMUP from misappropriation, but also in promoting the commercialisation of innovative TKMUP or inventions based on or derived from TKMUP in South Africa. However, this can only be possible if the challenges identified in this paper can be successfully navigated.

  18. Carbon steel protection in G.S. (Girlder sulfide) plants. CITROSOLV process influence. Pt. 6

    International Nuclear Information System (INIS)

    Lires, O.A.; Burkart, A.L.; Delfino, C.A.; Rojo, E.A.

    1988-01-01

    In order to protect carbon steel towers and piping of Girlder sulfide (G.S.) experimental heavy water plants against corrosion produced by the action of aqueous solutions of hydrogen sulfides, a method, previously published, was developed. Carbon steel, exposed to saturated aqueous solutions of hydrogen sulfide, forms iron sulfide scales. In oxygen free solutions evolution of corrosion follows the sequence: mackinawite → cubic ferrous sulfide → troilite → pyrrotite → pyrite. Scales formed by pyrrotite-pyrite or pyrite are the most protective layers (these are obtained at 130 deg C, 2 MPa, for periods of 14 days). CITROSOLV Process (Pfizer) is used to descaling and passivating stainless steel plant's components. This process must be used in mixed (carbon steel - stainless steel) circuits and may cause the formation of magnetite scales over the carbon steel. The influence of magnetite in the pyrrotite-pyrite scales formation is studied in this work. (Author) [es

  19. The humic acids from vermicompost protect rice (Oryza sativa L.) plants against a posterior hidric stress

    International Nuclear Information System (INIS)

    Guridi-Izquierdo, Fernando; Martínez-Balmori, Dariellys; Rosquete-Bassó, Mayelín; Calderín-García, Andrés; Louro-Berbara, Ricardo L.

    2017-01-01

    The humic acids (HA) from two different vermicompost were extracted, isolated, purified and partially characterized, to evaluate their possible protection in rice (Oryza sativa L.) plants against an hydric stress. Differences in elemental composition, as the coagulation threshold value and E4/E6 relation in their UV-Vis spectra were found. Two concentrations (40 and 60 mg L-1) of both HA were included in the nutritive solutions for rice plants in controlled conditions. It was verified that the previous treatment with the HA during six days stimulated the root biomass production. Later the HA were excluded and was an hydric deficit induced by adding polietilenglicol (PEG-6000) in the initially treated plants and in a group of those used as control. After 96 hours of this final condition the net radical biomass, the photosynthetic pigments content and the root membrane permeability were evaluated. In the plants previously treated with HA (at the concentration 60 mg HA L-1), the root membrane permeability, the net radical biomass production and the “a” chlorophyll content had no differences when compared with those without stress. It was concluded that the previous treatment with the HA protected the rice plants against a posterior hydric stress that was induced. (author)

  20. International guidelines for fire protection at nuclear installations including nuclear fuel plants, nuclear fuel stores, teaching reactors, research establishments

    International Nuclear Information System (INIS)

    The guidelines are recommended to designers, constructors, operators and insurers of nuclear fuel plants and other facilities using significant quantities of radioactive materials including research and teaching reactor installations where the reactors generally operate at less than approximately 10 MW(th). Recommendations for elementary precautions against fire risk at nuclear installations are followed by appendices on more specific topics. These cover: fire protection management and organization; precautions against loss during construction alterations and maintenance; basic fire protection for nuclear fuel plants; storage and nuclear fuel; and basic fire protection for research and training establishments. There are numerous illustrations of facilities referred to in the text. (U.K.)

  1. Real-time corrosion control system for cathodic protection of buried pipes for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Tae; Kim, Hae Woong; Kim, Young Sik [School of Materials Science and Engineering, Andong National University, Andong (Korea, Republic of); Chang, Hyun Young; Lim, Bu Taek; Park, Heung Bae [Power Engineering Research Institute, KEPCO Engineering and Construction Company, Seongnam (Korea, Republic of)

    2015-02-15

    Since the operation period of nuclear power plants has increased, the degradation of buried pipes gradually increases and recently it seems to be one of the emerging issues. Maintenance on buried pipes needs high quality of management system because outer surface of buried pipe contacts the various soils but inner surface reacts with various electrolytes of fluid. In the USA, USNRC and EPRI have tried to manage the degradation of buried pipes. However, there is little knowledge about the inspection procedure, test and manage program in the domestic nuclear power plants. This paper focuses on the development and build-up of real-time monitoring and control system of buried pipes. Pipes to be tested are tape-coated carbon steel pipe for primary component cooling water system, asphalt-coated cast iron pipe for fire protection system, and pre-stressed concrete cylinder pipe for sea water cooling system. A control system for cathodic protection was installed on each test pipe which has been monitored and controlled. For the calculation of protection range and optimization, computer simulation was performed using COMSOL Multiphysics (Altsoft co.)

  2. Real-time corrosion control system for cathodic protection of buried pipes for nuclear power plant

    International Nuclear Information System (INIS)

    Kim, Ki Tae; Kim, Hae Woong; Kim, Young Sik; Chang, Hyun Young; Lim, Bu Taek; Park, Heung Bae

    2015-01-01

    Since the operation period of nuclear power plants has increased, the degradation of buried pipes gradually increases and recently it seems to be one of the emerging issues. Maintenance on buried pipes needs high quality of management system because outer surface of buried pipe contacts the various soils but inner surface reacts with various electrolytes of fluid. In the USA, USNRC and EPRI have tried to manage the degradation of buried pipes. However, there is little knowledge about the inspection procedure, test and manage program in the domestic nuclear power plants. This paper focuses on the development and build-up of real-time monitoring and control system of buried pipes. Pipes to be tested are tape-coated carbon steel pipe for primary component cooling water system, asphalt-coated cast iron pipe for fire protection system, and pre-stressed concrete cylinder pipe for sea water cooling system. A control system for cathodic protection was installed on each test pipe which has been monitored and controlled. For the calculation of protection range and optimization, computer simulation was performed using COMSOL Multiphysics (Altsoft co.)

  3. Installation and commissioning of operation nuclear power plant reactor protection system modernization project

    International Nuclear Information System (INIS)

    Lu Weiwei

    2010-01-01

    Qinshan Nuclear Power Plant is the first nuclear power plant in mainland China; it is also the first one which realizes the modernization of analog technology based Reactor Protection System in the operation nuclear power plant of China. The implementation schedule is the shortest one which use same digital technology platform (TELEPERM XS of AREVA NP) to modifying the safety class I and C system in the world, the whole project spent 28 months from equipment contract signed to putting system into operation. It open up a era for operation nuclear power plant using mature digital technology to make safety class I and C system modernization in China. The important practical significance of this successful project is very obvious. This article focus on two important project stage--equipment installation and system commissioning, it is based on a large number of engineering implementation fact, it covers the problems and solutions happened during the installation and commission. The purpose of the article is to share the experience and lessons of safety I and C system modernization for other operation nuclear power plant. (authors)

  4. Survey of protected vascular plants on the Oak Ridge Reservation, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Awl, D.J.; Pounds, L.R.; Rosensteel, B.A.; King, A.L.; Hamlett, P.A.

    1996-06-01

    Vascular plant surveys were initiated during fiscal year 1992 by the environmentally sensitive areas program to determine the baseline condition of threatened and endangered (T&E) vascular plant species on the Oak Ridge Reservation (ORR). T&E species receive protection under federal and state regulations. In addition, the National Environmental Policy Act (NEPA) requires that federally-funded projects avoid or mitigate impacts to listed species. T&E plant species found on or near the U.S. Department of Energy`s (DOE) Oak Ridge Reservation (ORR) are identified. Twenty-eight species identified on the ORR are listed by the Tennessee Department of Environment and Conservation as either endangered, threatened, or of special concern. Four of these have been under review by the U.S. Fish and Wildlife Service for possible listing (listed in the formerly-used C2 candidate category). Additional species listed by the state occur near and may be present on the ORR. A range of habitats support the rare taxa on the ORR: river bluffs, sinkholes, calcareous barrens, wetlands, utility corridors, and forests. The list of T&E plant species and their locations on the ORR should be considered provisional because the entire ORR has not been surveyed, and state and federal status of all species continues to be updated. The purpose of this document is to present information on the listed T&E plant species currently known to occur on the ORR as well as listed species potentially occurring on the ORR based on geographic range and habitat availability. For the purpose of this report, {open_quotes}T&E species{close_quotes} include all federal- and state-listed species, including candidates for listing, and species of special concern. Consideration of T&E plant habitats is an important component of resource management and land-use planning; protection of rare species in their natural habitat is the best method of ensuring their long-term survival.

  5. Survey of protected vascular plants on the Oak Ridge Reservation, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Awl, D.J.; Pounds, L.R.; Rosensteel, B.A.; King, A.L.; Hamlett, P.A.

    1996-06-01

    Vascular plant surveys were initiated during fiscal year 1992 by the environmentally sensitive areas program to determine the baseline condition of threatened and endangered (T ampersand E) vascular plant species on the Oak Ridge Reservation (ORR). T ampersand E species receive protection under federal and state regulations. In addition, the National Environmental Policy Act (NEPA) requires that federally-funded projects avoid or mitigate impacts to listed species. T ampersand E plant species found on or near the U.S. Department of Energy's (DOE) Oak Ridge Reservation (ORR) are identified. Twenty-eight species identified on the ORR are listed by the Tennessee Department of Environment and Conservation as either endangered, threatened, or of special concern. Four of these have been under review by the U.S. Fish and Wildlife Service for possible listing (listed in the formerly-used C2 candidate category). Additional species listed by the state occur near and may be present on the ORR. A range of habitats support the rare taxa on the ORR: river bluffs, sinkholes, calcareous barrens, wetlands, utility corridors, and forests. The list of T ampersand E plant species and their locations on the ORR should be considered provisional because the entire ORR has not been surveyed, and state and federal status of all species continues to be updated. The purpose of this document is to present information on the listed T ampersand E plant species currently known to occur on the ORR as well as listed species potentially occurring on the ORR based on geographic range and habitat availability. For the purpose of this report, open-quotes T ampersand E speciesclose quotes include all federal- and state-listed species, including candidates for listing, and species of special concern. Consideration of T ampersand E plant habitats is an important component of resource management and land-use planning; protection of rare species in their natural habitat is the best method of ensuring their

  6. Estimating the energy independence of a municipal wastewater treatment plant incorporating green energy resources

    International Nuclear Information System (INIS)

    Chae, Kyu-Jung; Kang, Jihoon

    2013-01-01

    Highlights: • We estimated green energy production in a municipal wastewater treatment plant. • Engineered approaches in mining multiple green energy resources were presented. • The estimated green energy production accounted for 6.5% of energy independence in the plant. • We presented practical information regarding green energy projects in water infrastructures. - Abstract: Increasing energy prices and concerns about global climate change highlight the need to improve energy independence in municipal wastewater treatment plants (WWTPs). This paper presents methodologies for estimating the energy independence of a municipal WWTP with a design capacity of 30,000 m 3 /d incorporating various green energy resources into the existing facilities, including different types of 100 kW photovoltaics, 10 kW small hydropower, and an effluent heat recovery system with a 25 refrigeration ton heat pump. It also provides guidance for the selection of appropriate renewable technologies or their combinations for specific WWTP applications to reach energy self-sufficiency goals. The results showed that annual energy production equal to 107 tons of oil equivalent could be expected when the proposed green energy resources are implemented in the WWTP. The energy independence, which was defined as the percent ratio of green energy production to energy consumption, was estimated to be a maximum of 6.5% and to vary with on-site energy consumption in the WWTP. Implementing green energy resources tailored to specific site conditions is necessary to improve the energy independence in WWTPs. Most of the applied technologies were economically viable primarily because of the financial support under the mandatory renewable portfolio standard in Korea

  7. Aging assessment of surge protective devices in nuclear power plants

    International Nuclear Information System (INIS)

    Davis, J.F.; Subudhi, M.; Carroll, D.P.

    1996-01-01

    An assessment was performed to determine the effects of aging on the performance and availability of surge protective devices (SPDs), used in electrical power and control systems in nuclear power plants. Although SPDs have not been classified as safety-related, they are risk-important because they can minimize the initiating event frequencies associated with loss of offsite power and reactor trips. Conversely, their failure due to age might cause some of those initiating events, e.g., through short circuit failure modes, or by allowing deterioration of the safety-related component(s) they are protecting from overvoltages, perhaps preventing a reactor trip, from an open circuit failure mode. From the data evaluated during 1980--1994, it was found that failures of surge arresters and suppressers by short circuits were neither a significant risk nor safety concern, and there were no failures of surge suppressers preventing a reactor trip. Simulations, using the ElectroMagnetic Transients Program (EMTP) were performed to determine the adequacy of high voltage surge arresters

  8. Protection of nuclear power plants against external disasters

    International Nuclear Information System (INIS)

    Cottrell, W.B.

    1975-04-01

    A bibliography and a compilation of articles on the protection of nuclear power plants from external disasters are presented. The subject matter includes tornadoes and high winds, floods and high waves, earthquakes, plane crashes, sabotage and diversion, acts of war, and other disasters. The articles included in this compilation are primarily review articles on various topics selected from Nuclear Safety. Relevant AEC regulations, rulings, and regulatory guides are also included where appropriate. The bibliography with each section includes all recent literature on each topic, each with its own key-word, author, and permured title index. In addition, a brief commentary serves as an introduction to the report as well as to place its varied contents in perspective. An overall index to all textural material is also provided. (U.S.)

  9. Oral delivery of ACE2/Ang-(1-7) bioencapsulated in plant cells protects against experimental uveitis and autoimmune uveoretinitis.

    Science.gov (United States)

    Shil, Pollob K; Kwon, Kwang-Chul; Zhu, Ping; Verma, Amrisha; Daniell, Henry; Li, Qiuhong

    2014-12-01

    Hyperactivity of the renin-angiotensin system (RAS) resulting in elevated Angiotensin II (Ang II) contributes to all stages of inflammatory responses including ocular inflammation. The discovery of angiotensin-converting enzyme 2 (ACE2) has established a protective axis of RAS involving ACE2/Ang-(1-7)/Mas that counteracts the proinflammatory and hypertrophic effects of the deleterious ACE/AngII/AT1R axis. Here we investigated the hypothesis that enhancing the systemic and local activity of the protective axis of the RAS by oral delivery of ACE2 and Ang-(1-7) bioencapsulated in plant cells would confer protection against ocular inflammation. Both ACE2 and Ang-(1-7), fused with the non-toxic cholera toxin subunit B (CTB) were expressed in plant chloroplasts. Increased levels of ACE2 and Ang-(1-7) were observed in circulation and retina after oral administration of CTB-ACE2 and Ang-(1-7) expressing plant cells. Oral feeding of mice with bioencapsulated ACE2/Ang-(1-7) significantly reduced endotoxin-induced uveitis (EIU) in mice. Treatment with bioencapsulated ACE2/Ang-(1-7) also dramatically decreased cellular infiltration, retinal vasculitis, damage and folding in experimental autoimmune uveoretinitis (EAU). Thus, enhancing the protective axis of RAS by oral delivery of ACE2/Ang-(1-7) bioencapsulated in plant cells provide an innovative, highly efficient and cost-effective therapeutic strategy for ocular inflammatory diseases.

  10. Volatile Semiochemical Mediated Plant Defense in Cereals: A Novel Strategy for Crop Protection

    Directory of Open Access Journals (Sweden)

    Amanuel Tamiru

    2017-09-01

    Full Text Available Plants have evolved highly intriguing ways of defending themselves against insect attacks, including through emission of defense volatiles. These volatiles serve the plant’s defense by directly repelling phytophagous insects and/or indirectly through attracting natural enemies antagonistic to the herbivores. Several laboratory studies established the potential of improving plant resistance against insect attacks by manipulating the plant-derived volatile semiochemicals emissions. Yet, more efforts need to be conducted to translate the promising laboratory studies to fight economically-important crop pests under real field conditions. This is needed to address an increasing demand for alternative pest control options driven by ecological and environmental costs associated with the use of broad-spectrum insecticides. The practical examples discussed in this review paper demonstrate the real prospect of exploiting an inducible and constitutive plant volatile semiochemicals for developing novel and ecologically-sustainable pest management strategies to protect cereal crops from damaging insect pests.

  11. Protective effects of some medicinal plants from Lamiaceae family against beta-amyloid induced toxicity in PC12 cell

    Directory of Open Access Journals (Sweden)

    Balali P

    2012-10-01

    Full Text Available Background: Excessive accumulation of beta-amyliod peptide (Aβ, the major component of senile plaques in Alzheimer's disease (AD, causes neuronal cell death through induction of oxidative stress. Therefore, antioxidants may be of use in the treatment of AD. The medicinal plants from the Lamiaceae family have been widely used in Iranian traditional medicine. These plants contain compounds with antioxidant activity and some species in this family have been reported to have neuroprotective properties. In the present study, methanolic extract of seven plants from salvia and satureja species were evaluated for their protective effects against beta-amyloid induced neurotoxicity.Methods: Aerial parts of the plants were extracted with ethyl acetate and methanol, respectively, by percolation at room temperature and subsequently, methanolic extracts of the plants were prepared. PC12 cells were incubated with different concentrations of the extracts in culture medium 1h prior to incubation with Aβ. Cell toxicity was assessed 24h after addition of Aβ by MTT assay.Results: Satureja bachtiarica, Salvia officinalis and Salvia macrosiphon methanolic extracts exhibited high protective effects against Aβ induced toxicity (P<0.001. Protective effects of Satureja bachtiarica and Salvia officinalis were dose-dependent.Conclusion: The main constituents of these extracts are polyphenolic and flavonoid compounds such as rosmarinic acid, naringenin, apigenin and luteolin which have antioxidant properties and may have a role in neuroprotection. Based on neuroprotective effect of these plants against Aβ induced toxicity, we recommend greater attention to their use in the treatment of Alzheimer disease.

  12. Development of bricks with incorporation of coal ash and sludge from water treatment plant

    International Nuclear Information System (INIS)

    Silva, Mauro Valerio da

    2011-01-01

    Sludge from treatment water Brazilian plant station are, frequently, disposed and launched directly in the water bodies, causing a negative impact in the environment. Also, coal ashes is produced by burning of coal in coal-fired power stations and is the industrial solid waste most generated in southern Brazil: approximately 4 million tons/y. The efficient disposal of coal ashes is an issue due to its massive volume and harmful risks to the environment. The aim of this work was study the feasibility of incorporating these two industrial wastes in a mass used in the manufacture of ecological bricks. Samples of fly ashes from a cyclone filter from a coal-fired power plant located at Figueira County in Parana State, Brazil and waterworks sludge of Terra Preta County in Sao Paulo State, Brazil, were used in the study. Fly ash-sludge and fly ash-sludge-soil-cement bricks were molded and tested, according to the Brazilians Standards. The materials were characterized by physical-chemical analysis, X-ray diffraction, thermal analysis, morphological analysis, Fourier transform infrared spectroscopy and granulometric analysis. The results indicate that the waterworks sludge and coal ashes have potential to be used on manufacturing soil-cement pressed bricks according to the of Brazilians Standards NBR 10836/94. (author)

  13. INTEGRATED SYSTEMS IN PLANT PROTECTION MANAGEMENT: FIRE BLIGHT OF ROSACEOUS PLANTS (Erwinia amylovora (Burrill - Winslow IN AN APPLE ORCHARD IN SIBIU COUNTY

    Directory of Open Access Journals (Sweden)

    Maria TĂNASE

    2013-12-01

    Full Text Available Integrated protection represents a modern approach, denoting a protection strategy of agro-ecosystems; and it represents a complex system employing all appropriate methods in a manner as consistent and smooth as possible, in order to maintain the biocenotic balance of agrosystems and to keep pathogens at a level at which they do not cause economic damage (so-called level of eco-efficiency. A biocenotic approach to issues of agrosystem protection against disease attack requires an acknowledgement of all aspects regarding the evolution of pests in time and space, so as to be able to intervene at the right time with all possible means. And such protection measures are not supposed to restrain existing tendencies in the agrosystem. Therefore, this implies the awareness that any applied protection measures do not affect solely a certain pathogen, but the entire plant and animal community, as well as the soil and water.

  14. Correlating activity incorporation with properties of oxide films formed on material samples exposed to BWR and PWR coolants in Finnish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bojinov, M.; Kinnunen, P.; Laitinen, T.; Maekelae, K.; Saario, T.; Sirkiae, P. [VTT Industrial Systems, Espoo (Finland); Buddas, T.; Halin, M.; Kvarnstroem, R.; Tompuri, K. [Fortum Power and Heat Oy, Loviisa Power Plant, Loviisa (Finland); Helin, M.; Muttilainen, E.; Reinvall, A. [Teollisuuden Voima Oy, Olkiluoto (Finland)

    2002-07-01

    The extent of activity incorporation on primary circuit surfaces in nuclear power plants is connected to the chemical composition of the coolant, to the corrosion behaviour of the material surfaces and to the structure and properties of oxide films formed on circuit surfaces due to corrosion. Possible changes in operational conditions may induce changes in the structure of the oxide films and thus in the rate of activity incorporation. To predict these changes, experimental correlations between water chemistry, oxide films and activity incorporation, as well as mechanistic understanding of the related phenomena need to be established. In order to do this, flow-through cells with material samples and facilities for high-temperature water chemistry monitoring have been installed at Olkiluoto unit 1 (BWR) and Loviisa unit 1 (PWR) in spring 2000. The cells are being used for two major purposes: To observe the changes in the structure and activity levels of oxide films formed on material samples exposed to the primary coolant. Correlating these observations with the abundant chemical and radiochemical data on coolant composition, dose rates etc. collected routinely by the plant, as well as with high-temperature water chemistry monitoring data such as the corrosion potentials of relevant material samples, the redox potential and the high-temperature conductivity of the primary coolant. We describe in this paper the scope of the work, give examples of the observations made and summarize the results on oxide films that have been obtained during one full fuel cycle at both plants. (authors)

  15. Insights from a reliability review of digital plant protection system

    International Nuclear Information System (INIS)

    Kim, I.S.; Hwang, S.W.; Kim, B.S.; Jeong, C.H.; Oh, S.H.

    2001-01-01

    The full text follows: As part of the design efforts for Ulchin nuclear power plant units 5 and 6 of Korea, a reliability analysis of digital plant protection system (DPPS) was performed by ABB-CE. An independent review of the DPPS reliability analysis was undertaken by Hanyang University to assist Korea Institute of Nuclear Safety (KINS), the nuclear regulatory body of Korea, in evaluating the design acceptability of the digital system. The DPPS is designed to encompass both reactor trip function and ESFAS (engineered safety feature actuation system) initiation function. The major methods used by the ABB-CE to assess the Ulchin 5-6 DPPS reliability are failure mode and effect analysis (FMEA) and fault tree analysis. Hence, our independent review was conducted focusing on: -) the establishment of review criteria based on various sources, such as the standard review plan of KINS, 10CFR50 Appendix A, IEEE standards 279, 577, and 603; -) the suitability of the FMEA and fault tree analysis for the Ulchin 5-6 DPPS, including the specific methods used (e.g., for human reliability analysis and common-cause failure analysis), the assumptions made (e.g., with respect to test frequency and watchdog timer coverage), and the data employed (e.g., CCF parameter, human error probability, and processor failure rate); and -) the design acceptability of the DPPS especially as compared to the analog plant protection system from a reliability and safety perspective. The paper shall also discuss key issues requiring further in-depth investigation, such as reliability of programmable logic controllers (PLCs), coverage factor of watchdog timers, and susceptibility of redundant digital units to common cause failure. Sensitivity analyses were carried out to investigate the impact of several parameters of special interest, like the coverage factor of watchdog timer and human error probability (e.g. an operator error to manually trip the reactor, or to mis-calibrate the trip parameters) on

  16. Analytic study for physical protection system (PPS) in nuclear power plants (NPPs)

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Tae Ho, E-mail: thw@snu.ac.kr

    2013-12-15

    Highlights: • The physical protection system (PPS) is investigated. • General NPPs are modeled in the study. • Possible terror cases, likelihood, and consequence are studied. • PPS is constructed by analytical methods. - Abstract: The nuclear safeguard is analyzed in the aspect of the physical protection system (PPS) in nuclear power plants (NPPs). The PPS is reviewed and its related terror scenarios are investigated. The PPS is developed using analytical methods. In the terror scenarios, there are 8 possible cases for the terror attacks to the NPPs. Then, the likelihood of terror is classified by the general terror incidents. The consequence of terror is classified by Design Basis Threat (DBT) of the International Atomic Energy Agency (IAEA) scale. The physical protection method is suggested by defense-in-depth constraints and severe accident countermeasures. Finally, the advanced PPS is constructed, which could be used for the preparation for the possible terror attacks in the NPPs.

  17. Analytic study for physical protection system (PPS) in nuclear power plants (NPPs)

    International Nuclear Information System (INIS)

    Woo, Tae Ho

    2013-01-01

    Highlights: • The physical protection system (PPS) is investigated. • General NPPs are modeled in the study. • Possible terror cases, likelihood, and consequence are studied. • PPS is constructed by analytical methods. - Abstract: The nuclear safeguard is analyzed in the aspect of the physical protection system (PPS) in nuclear power plants (NPPs). The PPS is reviewed and its related terror scenarios are investigated. The PPS is developed using analytical methods. In the terror scenarios, there are 8 possible cases for the terror attacks to the NPPs. Then, the likelihood of terror is classified by the general terror incidents. The consequence of terror is classified by Design Basis Threat (DBT) of the International Atomic Energy Agency (IAEA) scale. The physical protection method is suggested by defense-in-depth constraints and severe accident countermeasures. Finally, the advanced PPS is constructed, which could be used for the preparation for the possible terror attacks in the NPPs

  18. Radiological protection of the unborn child. Recommendation of the Commission on Radiological Protection and scientific grounds

    International Nuclear Information System (INIS)

    Sarenio, O.

    2006-01-01

    The Commission on Radiological Protection was asked to give advice on the practical implications of the absorption of the maximum possible activity values that, under the Radiological Protection Ordinance, may be incorporated in women of child-bearing age occupationally exposed to radiation with regard to incorporation monitoring and compliance with the dose limit for the protection of the unborn child. An unborn child's conceivable level of exposure to radiation in the least favourable case due to continuous and single incorporations of radionuclides in the mother was determined on a nuclide-specific basis by the Federal Office for Radiation Protection with the aid of the mathematical metabolic models provided in ICRP 88. At the proposal of the Commission on Radiological Protection, the Federal Office for Radiation Protection considered the following very conservative scenarios: - the mother's maximum possible exposure due to a continuous intake of activity over 10 years prior to the pregnancy and in the first 10 weeks postconception based on the limits set out in the Radiological Protection Ordinance; - the mother's maximum possible exposure due to a single intake at the most unfavourable time in the first 10 weeks postconception based on the limits set out in the Radiological Protection Ordinance. Examination of these scenarios found that, with a few exceptions, the dose to the unborn child attributable to the incorporation of radiation in the mother summed up over 70 years is less than that to the mother. The committed effective dose to the unborn child from certain radionuclides may exceed the value of 1 mSv when the dose to the mother reaches the maximum limit. The Commission on Radiological Protection was therefore asked 1. to examine whether compliance with the limit of 1 mSv effective dose is sufficient for the protection of the unborn child or whether any additional limitation is required for individual organs, 2. to discuss the implications for

  19. Antelope bitterbrush reestablishment: a case study of plant size and browse protection effects.

    Science.gov (United States)

    G. Randy Johnson; Joel P. Okula

    2006-01-01

    After an intense stand-replacement fire in south-central Oregon, 1-y-old (1+0) bareroot seedlings of antelope bitterbrush (Purshia tridentata (Pursh) DC. [Rosaceae]) were outplanted over a 4-y period. Paired-plots were established to examine the benefits of protecting the plants from damage due to animal browsing with Vexar mesh tubing. In the first...

  20. 77 FR 59758 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection..., (RCRA), allows the Environmental Protection Agency (EPA) to authorize State hazardous waste management... codification of the authorized Idaho hazardous waste management program and incorporates by reference...

  1. 75 FR 17737 - Industrial Economics, Incorporated; Transfer of Data

    Science.gov (United States)

    2010-04-07

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPP-2010-0194; FRL-8820-2] Industrial Economics... (CBI) by the submitter, will be transferred to Industrial Economics, Incorporated in accordance with 40 CFR 2.307(h)(3) and 2.308(i)(2). Industrial Economics, Incorporated has been awarded multiple...

  2. GIS - An open window for environmental protection at nuclear power plants

    International Nuclear Information System (INIS)

    Zaplaic, M.; Iliuta, S.; Zaplaic, T.; Dragomir, A.; Zisu, D.; Deneanu, A.

    2008-01-01

    Full text: GIS platforms provide a useful tool to organize, analyze and illustrate geographically linked data. The combination between layers of general interest (traffic, water bodies, land cover, territorially - administrative units, landscape, a.s.o.) and those concerning the environmental protection at nuclear plants (industrial perimeter, pollution sources, risk zones, radioactivity maps based on monitoring data, etc.) could be used to illustrate potential or actual impacts, to assist risk analysis and emergency planning, and to facilitate the decision making. (authors)

  3. Physics contributions to radiation protection in nuclear power plants

    International Nuclear Information System (INIS)

    Krueger, F.W.

    1980-01-01

    Physical research and physical methods can essentially contribute to radiation protection in nuclear power plants. With their aid, properties of radiation sources can be determined, and calculations of radiation shields can be performed. In the present paper, such tasks are analyzed, the state of the art of their solution is evaluated, and trends of further work are shown. Focal points of the present study are the calculation of properties of radiation sources outside the reactor (fission products, activated corrosion products, decontamination facilities for contaminated media), exact and engineering methods for calculating radiation fields also in inhomogeneous shields, and classification of concretes for gamma-ray shielding. Objectives, possibilities, and problems of standardization of such activities are discussed. (author)

  4. The Application of Regulating Plant Growth into Protective Engineering of The Western Mansions Area in The Old Summer Palace

    Science.gov (United States)

    Cong, W.; Song, Y.

    2015-08-01

    The Western Mansions (Xīyáng Lóu) in the Old Summer Palace (Yuánmíngyuán ) are extremely valuable set of heritage. When it was first conceived and constructed, it was an important part of the successful exchange between Chinese and the Western cultures. It marked the entry of European architecture and the art of gardening into Chinese royal gardens. Therefore, the Western Mansions occupies a vital position in the garden history of China and even the world. Since the 1980s, the Administrative Office of the Old Summer Place (Yuánmíngyuán) had cleared and reorganized the Western Mansions relics. But currently, both the protection and display of the Western Mansions are far from satisfactory. With regards to the outlook of the cultural relics, there is cracking and collapses, relics are damaged by tourists, there is rainwater erosion, plant aggression, pollutants, weathering, crumbling and other threats. This is caused by the improper protective measures and the yearslong erosion through natural causes. Therefore, in order to protect the important heritage and show people the situation of the plant growth. As the basis of the copper planting, the historical conditions of planting can be speculated at the time of the western building, which become an important basis for the recovery of history. This paper also further researches on the informationg of plant form in history,to avoid destabilising the heritage.Some destruction from plant growth can be controled.

  5. Impacts of recreation and tourism on plant biodiversity and vegetation in protected areas in Australia.

    Science.gov (United States)

    Pickering, Catherine Marina; Hill, Wendy

    2007-12-01

    This paper reviews recent research into the impact of recreation and tourism in protected areas on plant biodiversity and vegetation communities in Australia. Despite the international significance of the Australian flora and increasing visitation to protected areas there has been limited research on recreational and tourism impacts in Australia. As overseas, there are obvious direct impacts of recreation and tourism such as clearing of vegetation for infrastructure or damage from trampling, horse riding, mountain biking and off road vehicles. As well, there are less obvious but potentially more severe indirect impacts. This includes self-propagating impacts associated with the spread of some weeds from trails and roads. It also includes the severe impact on native vegetation, including many rare and threatened plants, from spread of the root rot fungus Phytopthora cinnamomi. This review highlights the need for more recreational ecology research in Australia.

  6. PLANT PROTECTION PRODUCT RESIDUES IN APPLES, CAULIFLOWER, CEREALS, GRAPE, LETTUCE, PEAS, PEPPERS, POTATOES AND STRAWBERRIES OF THE SLOVENE ORIGIN IN 2006

    Directory of Open Access Journals (Sweden)

    Helena BAŠA ČESNIK

    2010-02-01

    Full Text Available In the year 2006, 181 apple, cauliflower, cereal, grape, lettuce, pea, pepper, potato and strawberry samples from Slovene producers were analysed for plant protection product residues. The samples were analysed for the presence of 86 different active compounds using four analytical methods. In nine samples (5.0 % exceeded maximum residue levels (MRLs were determined which is comparable with the results of the monitoring of plant protection product residues in products of plant origin in the European union, Norway, Iceland and Liechtenstein in 2005 (4.9 %.

  7. Research and engineering application of coordinated instrumentation control and protection technology between reactor and steam turbine generator on nuclear power plant

    International Nuclear Information System (INIS)

    Sun Xingdong

    2014-01-01

    The coordinated instrumentation control and protection technology between reactor and steam turbine generator (TG) usually is very significant and complicated for a new construction of nuclear power plant, because it carries the safety, economy and availability of nuclear power plant. Based on successful practice of a nuclear power plant, the experience on interface design and hardware architecture of coordinated instrumentation control and protection technology between reactor and steam turbine generator was abstracted and researched. In this paper, the key points and engineering experience were introduced to give the helpful instructions for the new project. (author)

  8. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    International Nuclear Information System (INIS)

    2005-01-01

    The DOE established the Groundwater Monitoring Program (GMP) (WP 02-1) to monitor groundwater resources at WIPP. In the past, the GMP was conducted to establish background data of existing conditions of groundwater quality and quantity in the WIPP vicinity, and to develop and maintain a water quality database as required by regulation. Today the GMP is conducted consistent with 204.1.500 NMAC (New Mexico Administrative Code), 'Adoption of 40 CFR [Code of Federal Regulations] Part 264,'specifically 40 CFR 264.90 through 264.101. These sections of 20.4.1 NMAC provide guidance for detection monitoring of groundwater that is, or could be, affected by waste management activities at WIPP. Detection monitoring at WIPP is designed to detect contaminants in the groundwater long before the general population is exposed. Early detection will allow cleanup efforts to be accomplished before any exposure to the general population can occur. Title 40 CFR Part 264, Subpart F, stipulates minimum requirements of Resource Conservation and Recovery Act of 1976 (42 United States Code [U.S.C.] 6901 et seq.) (RCRA) groundwater monitoring programs including the number and location of monitoring wells; sampling and reporting schedules; analytical methods and accuracy requirements; monitoring parameters; and statistical treatment of monitoring data. This document outlines how WIPP intends to protect and preserve groundwater within the WIPP Land Withdrawal Area (WLWA). Groundwater protection is just one aspect of the WIPP environmental protection effort. An overview of the entire environmental protection effort can be found in DOE/WIPP 99-2194, Waste Isolation Pilot Plant Environmental Monitoring Plan. The WIPP GMP is designed to statistically determine if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will then be determined and the appropriate corrective action(s) initiated.

  9. Waste Isolation Pilot Plant Groundwater Protection Management Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    Washington Regulatory and Environmental Services

    2005-07-01

    The DOE established the Groundwater Monitoring Program (GMP) (WP 02-1) to monitor groundwater resources at WIPP. In the past, the GMP was conducted to establish background data of existing conditions of groundwater quality and quantity in the WIPP vicinity, and to develop and maintain a water quality database as required by regulation. Today the GMP is conducted consistent with 204.1.500 NMAC (New MexicoAdministrative Code), "Adoption of 40 CFR [Code of Federal Regulations] Part 264,"specifically 40 CFR §264.90 through §264.101. These sections of 20.4.1 NMAC provide guidance for detection monitoring of groundwater that is, or could be, affected by waste management activities at WIPP. Detection monitoring at WIPP is designed to detect contaminants in the groundwater long before the general population is exposed. Early detection will allow cleanup efforts to be accomplished before any exposure to the general population can occur. Title 40 CFR Part 264, Subpart F, stipulates minimum requirements of Resource Conservation and Recovery Act of 1976 (42 United States Code [U.S.C.] §6901 et seq.) (RCRA) groundwater monitoring programs including the number and location of monitoring wells; sampling and reporting schedules; analytical methods and accuracy requirements; monitoring parameters; and statistical treatment of monitoring data. This document outlines how WIPP intends to protect and preserve groundwater within the WIPP Land Withdrawal Area (WLWA). Groundwater protection is just one aspect of the WIPP environmental protection effort. An overview of the entire environmental protection effort can be found in DOE/WIPP 99-2194, Waste Isolation Pilot Plant Environmental Monitoring Plan. The WIPP GMP is designed to statistically determine if any changes are occurring in groundwater characteristics within and surrounding the WIPP facility. If a change is noted, the cause will then be determined and the appropriate corrective action(s) initiated.

  10. Catch the Best: Novel Screening Strategy to Select Stress Protecting Agents for Crop Plants

    Directory of Open Access Journals (Sweden)

    Christin Zachow

    2013-11-01

    Full Text Available Climate change increases stress levels for crops and affects the economic and environmental aspects of agricultural management systems. The application of stress tolerance-mediating microorganisms is an auspicious strategy for improving crop protection, and as such, we developed a direct selection strategy to obtain cultivable microorganisms from promising bioresources using the bait plants, maize, oilseed rape, sorghum and sugar beet. Alpine mosses, lichens and primrose were selected as bioresources, as each is adapted to adverse environmental conditions. A 10% crop-specific selection was found for bait plant rhizosphere communities using cultivation-independent fingerprints, and their potential role as stress protecting agents (SPA was evaluated following the cultivation of captured bacteria. In addition to assays identifying phytopathogen antagonism and plant growth promotion capacities, our evaluation included those that test the ability to allocate nutrients. Moreover, we developed new assays to measure tolerance in diverse stress conditions. A score scheme was applied to select SPAs with desired properties, and three Pseudomonas species with pronounced antagonistic activity that showed elevated tolerance to desiccation and an improved seed germination rate were subsequently chosen. Screening for environmentally-conditioned and host-adapted microorganisms provides a novel tool for target-oriented exploitation of microbial bioresources for the management of ecofriendly crops facing biotic and abiotic stresses.

  11. Modelling plant invasion pathways in protected areas under climate change: implication for invasion management

    Directory of Open Access Journals (Sweden)

    C.-J. Wang

    2017-12-01

    Full Text Available Global climate change may enable invasive plant species (IPS to invade protected areas (PAs, but plant invasion on a global scale has not yet been explicitly addressed. Here, we mapped the potential invasion pathways for IPS in PAs across the globe and explored potential factors determining the pathways of plant invasion under climate change. We used species distribution modelling to estimate the suitable habitats of 386 IPS and applied a corridor analysis to compute the potential pathways of IPS in PAs under climate change. Subsequently, we analysed the potential factors affecting the pathways in PAs. According to our results, the main potential pathways of IPS in PAs are in Europe, eastern Australia, New Zealand, southern Africa, and eastern regions of South America and are strongly influenced by changes in temperature and precipitation. Protected areas can play an important role in preventing and controlling the spread of IPS under climate change. This is due to the fact that measures are taken to monitor climate change in detail, to provide effective management near or inside PAs, and to control the introduction of IPS with a high capacity for natural dispersal. A review of conservation policies in PAs is urgently needed.

  12. Effects of ionizing radiation on plants and animals at levels implied by current radiation protection standards

    International Nuclear Information System (INIS)

    1992-01-01

    The 1977 Recommendations of the International Commission on Radiological Protection stated that the commission believes that if man is adequately protected from radiation, other organisms are also likely to be sufficiently protected. The present report examines this statement by considering the effects of ionizing radiation on animals and plants in both terrestrial and aquatic ecosystems. The conclusions are that chronic dose rates of IMGy.d -1 or less are unlikely to cause measurable deleterious effects in terrestrial populations, and that in the aquatic environment limiting chronic dose rates to 10MGy.d -1 to the maximally exposed individuals would provide adequate protection for the population. Thus specific radiation protection standards for non-human organisms are not needed. 193 refs, 2 figs, 7 tabs

  13. Identification of the protective effects of traditional medicinal plants against SDS-induced Drosophila gut damage.

    Science.gov (United States)

    Zhou, Yang; Liu, Zonglin; Chen, Yuchen; Jin, Li Hua

    2016-10-01

    Traditional medicinal plants are widely used as immunomodulatory medicines that help improve health. A total of 50 different plants used for the treatment of toxicity were screened for their in vivo protective effects. Flies were fed a standard cornmeal-yeast medium (control group) or the standard medium containing medicinal plant extracts (experimental groups). Assessment of the survival rate was performed by feeding flies with toxic compounds. Gut epithelial cells were analyzed for cell proliferation and death by green fluorescent protein antibodies and 7-aminoactinomycin D staining under the microscope. The expression of antimicrobial peptides (AMPs) was evaluated by the quantitative polymerase chain reaction and the results revealed that after feeding the flies with toxic compounds, aqueous extracts from Codonopsis pilosula (Franch.) Nannf ( C. pilosula ), Saussurea lappa (Decne.) C.B.Clarke ( S. lappa ), Imperata cylindrica Beauv.var. major (Nees) C.E. Hubb. ( I. cylindrical var. major ) and Melia toosendan Sied. Et Zucc. ( M.toosendan ) increased the fly survival rate, reduced epithelial cell death and improved gut morphology. In addition, C. pilosula extracts induced the antimicrobial peptide levels (Dpt and Mtk) following treatment with sodium dodecyl sulfate (SDS). However, these extracts were not observed to increase SDS-induced cell proliferation in vivo . These results indicate that there are strong protective effects in extracts of C. pilosula , S. lappa , I. cylindrical var. major and M. toosendan on Drosophila intestinal cells among 50 medicinal plants.

  14. Evidence for a universal pathway of abscisic acid biosynthesis in higher plants from sup 18 O incorporation patterns

    Energy Technology Data Exchange (ETDEWEB)

    Zeevaart, J.A.D.; Heath, T.G.; Gage, D.A. (Michigan State University, East Lansing (USA))

    1989-12-01

    Previous labeling studies of abscisic acid (ABA) with {sup 18}O{sub 2} have been mainly conducted with water-stressed leaves. In this study, {sup 18}O incorporation into ABA of stressed leaves of various species was compared with {sup 18}O labeling of ABA of turgid leaves and of fruit tissue in different stages of ripening. In stressed leaves of all six species investigated, avocado (Persea americana), barley (Hordeum vulgare), bean (Phaseolus vulgaris), cocklebur (Xanthium strumarium), spinach (Spinacia oleracea), and tobacco (Nicotiana tabacum), {sup 18}O was most abundant in the carboxyl group, whereas incorporation of a second and third {sup 18}O in the oxygen atoms on the ring of ABA was much less prominent after 24 h in {sup 18}O{sub 2}. ABA from turgid bean leaves showed significant {sup 18}O incorporation, again with highest {sup 18}O enrichment in the carboxyl group. On the basis of {sup 18}O-labeling patterns observed in ABA from different tissues it is concluded that, despite variations in precusor pool sizes and intermediate turnover rates, there is a universal pathway of ABA biosynthesis in higher plants which involves cleavage of a larger precursor molecule, presumably an oxygenated carotenoid.

  15. Architectural and structural engineering aspects of protective design for nuclear power plants against terrorist attack

    International Nuclear Information System (INIS)

    Musacchio, J.M.; Rozen, A.

    1987-01-01

    This paper presents the results of several threat studies which have been performed, provides collective data on costs, and discusses, in a general sense, architectural/structural aspects of passive protection design measures which have been developed and utilized at several nuclear power plants. By combining relevant architectural and structural measures in the standard design, it is possible to substantially reduce the vulnerability of nuclear power plants to terrorist attack and the estimated damage to a manageable level with a minimal investment. (orig./HP)

  16. Radiation protection program applied to occupationally exposed individuals at the IPEN/CNEN-SP pilot plant in the 1980s for natural uranium compounds

    International Nuclear Information System (INIS)

    Silva, Teresinha de Moraes da; Sordi, Gian Maria A.A.; Vasques, Francisco Mário Feijó

    2017-01-01

    The work evidences the chemical processing of natural uranium from the yellowcake phase to the production of UF 6 natural uranium hexafluoride, a process carried out at the IPEN/CNEN-SP pilot plant. Radiation protection management was intended to monitor occupationally exposed individuals - IOEs, the workplace and the environment. An individual monitoring program for IOEs was developed for both external irradiation and incorporation of radioactive material. The IOEs were monitored externally with film-type dosimeters and the in vitro method was applied internally for urine analysis. For the workplace the monitoring program for equipment and floors was developed, determining the exposure rate from the process equipment, surface contamination expressed in Bq.cm -2 in equipment and floors, complemented by the air monitoring program both for the worker as well as for the workplace. Cellulose filters with aerodynamic diameter of 0.3 micron to 8.0 micron were used

  17. The Material Protection, Control and Accounting Sustainability Program Implementation at the Electrochemical Plant

    International Nuclear Information System (INIS)

    Sirotenko, Vladimir; Antonov, Eduard; Sirotenko, Alexei; Kukartsev, Alexander; Krivenko, Vladimir; Dabbs, Richard D.; Carroll, Michael F.; Garrett, Albert G.; Patrick, Scott W.; Ku, Esther M.

    2008-01-01

    Joint efforts by the Electrochemical Plant (ECP) in Zelenogorsk, Russia, and the United States Department of Energy National Nuclear Security Administration (US DOE/NNSA) Material Protection, Control and Accounting (MPC and A) Program to upgrade ECP security systems began in 1996. The commissioning of major MPC and A systems at ECP occurred in December 2004. Since that time, the US Project Team (USPT) and ECP personnel have focused jointly on the development and implementation of an enterprise-wide MPC and A Sustainability Program (SP) that address the seven essential MPC and A Program sustainability elements. This paper describes current operational experience at the ECP with the full implementation of the site SP utilizing an earned-value methodology. In support of this site program, ECP has established a Document Control Program (DCP) for sustainability-related documents; developed a robust master Work Breakdown Structure (WBS) that outlines all ECP MPC and A sustainability activities; and chartered an Enterprise-Wide Sustainability Working Group (ESWG) The earned value methodology uses ECP-completed (and USPT-verified) analyses to assess project performance on a quarterly basis. The MPC and A SP, presently operational through a contract between ECP and the Los Alamos National Laboratory (LANL), incorporates the seven essential MPC and A Program sustainability elements and governs all sustainability activities associated with MPC and A systems at ECP. The site SP is designed to ensure over the near term the upgraded MPC and A systems continuous operation at ECP as funding transitions from US-assisted to fully Russian supported and sustained

  18. Scientific Opinion addressing the state of the science on risk assessment of plant protection products for in-soil organisms

    DEFF Research Database (Denmark)

    EFSA PPR Panel (EFSA Panel on Plant Protection Products and their Residues); Ockleford, Colin; Adriaanse, Paulien

    2017-01-01

    Following a request from EFSA, the Panel on Plant Protection Products and their Residues developed an opinion on the science behind the risk assessment of plant protection products for in-soil organisms. The current risk assessment scheme is reviewed, taking into account new regulatory frameworks...... exposure routes for in-soil organisms and the potential direct and indirect effects is proposed. In order to address species recovery and long-term impacts of PPPs, the use of population models is also proposed....... and scientific developments. Proposals are made for specific protection goals for in-soil organisms being key drivers for relevant ecosystem services in agricultural landscapes such as nutrient cycling, soil structure, pest control and biodiversity. Considering the time-scales and biological processes related...

  19. Incorporation of Fe3O4/CNTs nanocomposite in an epoxy coating for corrosion protection of carbon steel

    Science.gov (United States)

    Pham, Gia Vu; Truc Trinh, Anh; To, Thi Xuan Hang; Duong Nguyen, Thuy; Trang Nguyen, Thu; Hoan Nguyen, Xuan

    2014-09-01

    In this study Fe3O4/CNTs composite with magnetic property was prepared by attaching magnetic nanoparticles (Fe3O4) to carbon nanotubes (CNTs) by hydrothermal method. The obtained Fe3O4/CNTs composite was characterized by Fourier transform infrared (FTIR) spectroscopy, powder x-ray diffraction and transmission electron microscopy. The Fe3O4/CNTs composite was then incorporated into an epoxy coating at concentration of 3 wt%. Corrosion protection of epoxy coating containing Fe3O4/CNTs composite was evaluated by electrochemical impedance spectroscopy and adhesion measurement. The impedance measurements show that Fe3O4/CNTs composite enhanced the corrosion protection of epoxy coating. The corrosion resistance of the carbon steel coated by epoxy coating containing Fe3O4/CNTs composite was significantly higher than that of carbon steel coated by clear epoxy coating and epoxy coating containing CNTs. FE-SEM photographs of fracture surface of coatings showed good dispersion of Fe3O4/CNTs composite in the epoxy matrix.

  20. Incorporation of Fe3O4/CNTs nanocomposite in an epoxy coating for corrosion protection of carbon steel

    International Nuclear Information System (INIS)

    Pham, Gia Vu; Trinh, Anh Truc; Hang To, Thi Xuan; Nguyen, Thuy Duong; Nguyen, Thu Trang; Nguyen, Xuan Hoan

    2014-01-01

    In this study Fe 3 O 4 /CNTs composite with magnetic property was prepared by attaching magnetic nanoparticles (Fe 3 O 4 ) to carbon nanotubes (CNTs) by hydrothermal method. The obtained Fe 3 O 4 /CNTs composite was characterized by Fourier transform infrared (FTIR) spectroscopy, powder x-ray diffraction and transmission electron microscopy. The Fe 3 O 4 /CNTs composite was then incorporated into an epoxy coating at concentration of 3 wt%. Corrosion protection of epoxy coating containing Fe 3 O 4 /CNTs composite was evaluated by electrochemical impedance spectroscopy and adhesion measurement. The impedance measurements show that Fe 3 O 4 /CNTs composite enhanced the corrosion protection of epoxy coating. The corrosion resistance of the carbon steel coated by epoxy coating containing Fe 3 O 4 /CNTs composite was significantly higher than that of carbon steel coated by clear epoxy coating and epoxy coating containing CNTs. FE-SEM photographs of fracture surface of coatings showed good dispersion of Fe 3 O 4 /CNTs composite in the epoxy matrix. (paper)

  1. Risk exposures for human ornithosis in a poultry processing plant modified by use of personal protective equipment: an analytical outbreak study.

    Science.gov (United States)

    Williams, C J; Sillis, M; Fearne, V; Pezzoli, L; Beasley, G; Bracebridge, S; Reacher, M; Nair, P

    2013-09-01

    Ornithosis outbreaks in poultry processing plants are well-described, but evidence for preventive measures is currently lacking. This study describes a case-control study into an outbreak of ornithosis at a poultry processing plant in the East of England, identified following three employees being admitted to hospital. Workers at the affected plant were recruited via their employer, with exposures assessed using a self-completed questionnaire. Cases were ascertained using serological methods or direct antigen detection in sputum. 63/225 (28%) staff participated, with 10% of participants showing evidence of recent infection. Exposure to the killing/defeathering and automated evisceration areas, and contact with viscera or blood were the main risk factors for infection. Personal protective equipment (goggles and FFP3 masks) reduced the effect of exposure to risk areas and to self-contamination with potentially infectious material. Our study provides some evidence of effectiveness for respiratory protective equipment in poultry processing plants where there is a known and current risk of ornithosis. Further studies are required to confirm this tentative finding, but in the meantime respiratory protective equipment is recommended as a precautionary measure in plants where outbreaks of ornithosis occur.

  2. Paraheliotropism can protect water-stressed bean (Phaseolus vulgaris L.) plants against photoinhibition.

    Science.gov (United States)

    Pastenes, Claudio; Porter, Victor; Baginsky, Cecilia; Horton, Peter; González, Javiera

    2004-12-01

    In order to estimate the importance of leaf movements on photosynthesis in well-watered and water-stressed field grown bean cultivars (Arroz Tuscola (AT), Orfeo INIA (OI), Bayos Titan (BT), and Hallados Dorado (HD)), CO2 assimilation, leaf temperature, and capacity for the maximum quantum yield recovery, measured as Fv/Fm, were assessed. Leaf water potential was lower in water-stressed compared to control plants throughout the day. Water status determined a decrease in the CO2 assimilation and stomatal conductance as light intensity and temperature increased up to maximal intensities at midday. Both parameters were lower in stressed compared to control plants. Even though high light intensity and water-stress induced stomatal closure is regarded as a photoinhibitory condition, the recovery of variable to maximal fluorescence (Fv/Fm) after 30min of darkness was nearly constant in both water regimes. In fact, higher values were observed in OI and AT when under stress. Photochemical and non-photochemical fluorescence quenching resulted in minor changes during the day and were similar between watered and stressed plants. It is concluded that paraheliotropism, present in the four bean cultivars, efficiently protects stressed plants from photoinhibition in the field and helps maintain leaf temperatures far below the ambient temperatures, however, it may also be responsible for low CO2 assimilation rates in watered plants.

  3. Insights of the periodic reviews regarding the physical protection of nuclear power plants designed to earlier standards

    International Nuclear Information System (INIS)

    Hagemann, A.

    2001-01-01

    Among other prerequisites for licensing a nuclear activity, the German Atomic Energy Act stipulates that the necessary physical protection against malevolent acts has to be approved before granting a license. This is required for nuclear power plants in paragraph 7 of the Atomic Energy Act. The licenses for nuclear power plants designed to earlier standards were granted about 20 years ago and more. All NPPs are under the supervision of the Supervisory Authority in order to ensure that all conditions of the license are met during the whole plant operation period. The 'Periodic Safety Review', PSR, is designated to provide the Supervisory Authority with additional information on the safety status. One part of the PSR is the 'Deterministic Security Analysis', DSA. The subject of the DSA is the actual physical protection of a NPP. The following document outlines the experiences gained during the evaluation of DSA reports by GRS as an external expert organisation under contract of the Supervisory Authorities. (author)

  4. Insights of the periodic reviews regarding the physical protection of nuclear power plants designed to earlier standards

    Energy Technology Data Exchange (ETDEWEB)

    Hagemann, A. [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Cologne (Germany)

    2001-07-01

    Among other prerequisites for licensing a nuclear activity, the German Atomic Energy Act stipulates that the necessary physical protection against malevolent acts has to be approved before granting a license. This is required for nuclear power plants in paragraph 7 of the Atomic Energy Act. The licenses for nuclear power plants designed to earlier standards were granted about 20 years ago and more. All NPPs are under the supervision of the Supervisory Authority in order to ensure that all conditions of the license are met during the whole plant operation period. The 'Periodic Safety Review', PSR, is designated to provide the Supervisory Authority with additional information on the safety status. One part of the PSR is the 'Deterministic Security Analysis', DSA. The subject of the DSA is the actual physical protection of a NPP. The following document outlines the experiences gained during the evaluation of DSA reports by GRS as an external expert organisation under contract of the Supervisory Authorities. (author)

  5. Synergism in mutations induction in Tradescantia by plants protection agents acting jointly with ionizing radiation

    International Nuclear Information System (INIS)

    Cebulska-Wasilewska, A.; Smagala, J.

    1990-01-01

    Tradescantia was first treated by plants protection agents such as: Ambusz, Afalton, Ripcord, Decis, deltametryne and after that irradiated with X radiation. The synergism of both factors was observed. The mutation frequency dependence on radiation doses was studied. 7 figs., 4 refs. (A.S.)

  6. Application of crime countermeasures for the protection of nuclear materials

    International Nuclear Information System (INIS)

    Bean, C.H.

    1975-01-01

    Federal regulations prepared by the Nuclear Regulatory Commission and published in the Federal Register require licensees to take appropriate action to protect the health and safety of the public from unauthorized use of special nuclear material (SNM), which includes plutonium, uranium-233, and highly enriched uranium. Crime countermeasures for compliance with these regulations are an important part of the guidance that is provided by the NRC's Office of Standards Development. The use of crime countermeasures and protective devices is intended to prevent the unauthorized diversion of material and to aid in the detection of diversion should it be attempted. Plant and equipment designs should incorporate both electronic and physical security measures for protection of SNM. This applies to facilities and equipment for reprocessing, fabrication, and transportation of SNM. The protection systems include physical barriers, access controls, intrusion detection devices, surveillance devices, central alarm stations, communications, and response capability. Acceptable security measures and devices applicable to protected areas, material access areas, vital areas, vital equipment, and transportation vehicles have been presented in Regulatory Guides. (U.S.)

  7. Safety philosophy in upgrading the EBR-II plant protection system

    International Nuclear Information System (INIS)

    Sackett, J.I.

    1976-01-01

    The EBR-II plant protection system (PPS) has been substantially modified, upgrading its performance to more fully comply with modern safety philosophy and criteria. The upgrading effort required that the total reactor system be evaluated for possible faults and that a PPS be designed to accommodate them. The result was deletion of a number of existing trip functions and upgrading of others. Particular attention was given to loss of primary pumping power and reactivity insertion events. The design and performance criteria for the PPS has been more firmly established, understanding of the PPS function has been improved and the reactor has been subjected to fewer spurious trips, improving operational reliability

  8. Nuclear safety and radiation protection report of the Tricastin power plant - 2013

    International Nuclear Information System (INIS)

    2014-01-01

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Tricastin nuclear power plant (INB 87 and 88, Saint-Paul-Trois-Chateaux, Drome (FR)). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2013, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, The radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions

  9. Nuclear safety and radiation protection report of the Tricastin power plant - 2014

    International Nuclear Information System (INIS)

    2015-01-01

    This safety report was established under the article 21 of the French law no. 2006-686 of June 13, 2006 relative to nuclear safety and information transparency. It presents, first, the facilities of the Tricastin nuclear power plant (INB 87 and 88, Saint-Paul-Trois-Chateaux, Drome (FR)). Then, the nuclear safety and radiation protection measures taken regarding the facilities are reviewed: nuclear safety definition, radiation protection of intervening parties, safety and radiation protection improvement paths, crisis management, external and internal controls, technical situation of facilities, administrative procedures in progress. The incidents and accidents which occurred in 2014, are reported as well as the radioactive and non-radioactive (chemical, thermal) effluents discharge in the environment. Finally, the radioactive materials and wastes generated by the facilities are presented and sorted by type of waste, quantities and type of conditioning. Other environmental impacts (noise) are presented with their mitigation measures. Actions in favour of transparency and public information are presented as well. The document concludes with a glossary and a list of recommendations from the Committees for health, safety and working conditions

  10. A Study on Salt Attack Protection of Structural and Finishing Materials in Power Plant Structures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, W.B.; Kweon, K.J.; Suh, Y.P.; Nah, H.S.; Lee, K.J.; Park, D.S.; Jo, Y.K. [Korea Electric Power Research Institute, Taejeon (Korea, Republic of)

    1997-12-31

    This is a final report written by both KEPRI and KICT as a co-operative research titled {sup A} study on Salt Protection of Structural and Finishings in Power Plant Structures{sup .} This study presented the methods to prevent the chloride-induced corrosion of power plant structures through collection and analysis of research datum relating to design, construction and maintenance for the prevention of structural and finishing materials, thru material performance tests for anti-corrosion under many kinds of chloride-induced corrosion environments. As a result, this study proposed the guidelines for design, construction and maintenance of power plant structures due to chloride-induced corrosion. (author). 257 refs., 111 figs., 86 tabs.

  11. A Study on Salt Attack Protection of Structural and Finishing Materials in Power Plant Structures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, W B; Kweon, K J; Suh, Y P; Nah, H S; Lee, K J; Park, D S; Jo, Y K [Korea Electric Power Research Institute, Taejeon (Korea, Republic of)

    1998-12-31

    This is a final report written by both KEPRI and KICT as a co-operative research titled {sup A} study on Salt Protection of Structural and Finishings in Power Plant Structures{sup .} This study presented the methods to prevent the chloride-induced corrosion of power plant structures through collection and analysis of research datum relating to design, construction and maintenance for the prevention of structural and finishing materials, thru material performance tests for anti-corrosion under many kinds of chloride-induced corrosion environments. As a result, this study proposed the guidelines for design, construction and maintenance of power plant structures due to chloride-induced corrosion. (author). 257 refs., 111 figs., 86 tabs.

  12. Creating space for ‘informal’ seed systems in a plant variety protection system that is based on UPOV 1991

    NARCIS (Netherlands)

    Jonge, de B.; Munyi, P.

    2017-01-01

    Summary
    Plant variety protection (PVP) gives a right holder
    (breeder) the possibility to exclude others from using his
    or her invention (plant variety) for a particular period.
    African regional organizations are currently establishing
    PVP systems that are in line with the

  13. Responsive Polymers for Crop Protection

    Directory of Open Access Journals (Sweden)

    Serban F. Peteu

    2010-08-01

    Full Text Available This review outlines the responsive polymer methods currently in use with their potential application to plant protection and puts forward plant-specific mechanisms as stimuli in newly devised methods for smart release of crop protection agents (CPAs. CPAs include chemicals (fungicides, insecticides, herbicides, biochemicals (antibiotics, RNA-based vaccines for plant viruses, semiochemicals (pheromones, repellents, allomones, microbial pesticides, growth regulators (insect and plant or micronutrients, all with crop protection effects. This appraisal focuses on emerging uses of polymer nano-encapsulated CPAs. Firstly, the most interesting advances in controlled release methods are critically discussed with their advantages and drawbacks. Secondly, several plant-specific stimuli-based smart methods are anticipated for use alongside the polymer nano- or micro-capsules. These new CPA release methods are designed to (i protect plants against infection produced by fungi or bacteria, and (ii apply micro-nutrients when the plants need it the most. Thus, we foresee (i the responsive release of nano- encapsulated bio-insecticides regulated by plant stress enzymes, and (ii the delivery of micro-nutrients synchronized by the nature or intensity of plant root exudates. Such continued advances of nano-scale smart polymer-based CPAs for the protection of crops herald a “small revolution” for the benefit of sustainable agriculture.

  14. Radiation and Environmental Protection Programme for the First Upcoming Nuclear Power Plant in Indonesia

    International Nuclear Information System (INIS)

    Syahrir

    2007-01-01

    Indonesia plans to operate the first nuclear power plant (NPP) by 2016. A radiation and environmental protection arrangement for NPPs is part of the whole safety system which is embedded in every practice involved radiation exposure to workers and members of public. A radiation and environmental protection programme for the NPP should adhere to international standards and mainstream in order to be acceptable to the public and international communities. International Atomic Energy Agency (IAEA) has recommended a radiation protection standard for NPPs as studied in this paper. Focus is given to the operational aspects of radiation protection program and discharge control to the environment. Some documents related to Safety Analysis Reports were used as working examples on its implementation. The study includes the classification of working areas and access control; local rules and supervision of work; work planning and work permits; protective clothing and protective equipment; facilities, shielding and equipment; application of the principle of optimization of protection; and removal or reduction in intensity of sources of radiation. The radiological protection aspects blend together in the whole NPP practices, each individual has his/her own responsibility in association with the radiation protection program implementation. It also present in the whole steps of NPP preparation up to its decommissioning. Promise on safety improvement and significant dose reduction in the recent development in NPP technology should scrutinized so that the option of proven technology as required in commercial power reactor licensing considers this tendency. (author)

  15. Fire protection of safe shutdown capability at commercial nuclear power plants

    International Nuclear Information System (INIS)

    Sullivan, K.

    1993-01-01

    The comprehensive industrial safety standards and codes that exist today have evolved from lessons learned through past experience, research results, and improvements in technological capabilities. The current requirements for fire safety features of commercial nuclear power stations operated in the U.S. are a notable example of this practice. Although fire protection has always been an important design requirement, from the aftermath of a serious fire that occurred in 1975 at the Browns Ferry plant, it was learned that the life safety and property protection concerns of the major fire insurance underwriters may not sufficiently encompass nuclear safety issues, particularly with regard to the potential for fire damage to result in the common mode failure of redundant trains of systems, and composites important to the safe shutdown of the reactor. Following its investigations into the Browns Ferry fire, the Nuclear Regulatory Commission (NRC) promulgated guidance documents, which ultimately developed into mandatory regulations, necessary to assure the implementation of a fire protection program that would address nuclear safety concerns. The new criteria that evolved, contain prescriptive design features, as well as personnel and administrative requirements the Commission determined to be necessary to provide a defense-in-depth level of protection against the hazards of fire and its associated effects on safety related equipment. These criteria are primarily contained in Appendix R of Title 10 to the Code of Federal Regulations (10 CFR 50)

  16. Direct imaging of glycans in Arabidopsis roots via click labeling of metabolically incorporated azido-monosaccharides.

    Science.gov (United States)

    Hoogenboom, Jorin; Berghuis, Nathalja; Cramer, Dario; Geurts, Rene; Zuilhof, Han; Wennekes, Tom

    2016-10-10

    Carbohydrates, also called glycans, play a crucial but not fully understood role in plant health and development. The non-template driven formation of glycans makes it impossible to image them in vivo with genetically encoded fluorescent tags and related molecular biology approaches. A solution to this problem is the use of tailor-made glycan analogs that are metabolically incorporated by the plant into its glycans. These metabolically incorporated probes can be visualized, but techniques documented so far use toxic copper-catalyzed labeling. To further expand our knowledge of plant glycobiology by direct imaging of its glycans via this method, there is need for novel click-compatible glycan analogs for plants that can be bioorthogonally labelled via copper-free techniques. Arabidopsis seedlings were incubated with azido-containing monosaccharide analogs of N-acetylglucosamine, N-acetylgalactosamine, L-fucose, and L-arabinofuranose. These azido-monosaccharides were metabolically incorporated in plant cell wall glycans of Arabidopsis seedlings. Control experiments indicated active metabolic incorporation of the azido-monosaccharide analogs into glycans rather than through non-specific absorption of the glycan analogs onto the plant cell wall. Successful copper-free labeling reactions were performed, namely an inverse-electron demand Diels-Alder cycloaddition reaction using an incorporated N-acetylglucosamine analog, and a strain-promoted azide-alkyne click reaction. All evaluated azido-monosaccharide analogs were observed to be non-toxic at the used concentrations under normal growth conditions. Our results for the metabolic incorporation and fluorescent labeling of these azido-monosaccharide analogs expand the possibilities for studying plant glycans by direct imaging. Overall we successfully evaluated five azido-monosaccharide analogs for their ability to be metabolically incorporated in Arabidopsis roots and their imaging after fluorescent labeling. This expands

  17. Mathematical verification of a nuclear power plant protection system function with combined CPN and PVS

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Seo Ryong; Son, Han Seong; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1999-12-31

    In this work, an automatic software verification method for Nuclear Power Plant (NPP) protection system is developed. This method utilizes Colored Petri Net (CPN) for modeling and Prototype Verification System (PVS) for mathematical verification. In order to help flow-through from modeling by CPN to mathematical proof by PVS, a translator has been developed in this work. The combined method has been applied to a protection system function of Wolsong NPP SDS2(Steam Generator Low Level Trip) and found to be promising for further research and applications. 7 refs., 10 figs. (Author)

  18. Mathematical verification of a nuclear power plant protection system function with combined CPN and PVS

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Seo Ryong; Son, Han Seong; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    In this work, an automatic software verification method for Nuclear Power Plant (NPP) protection system is developed. This method utilizes Colored Petri Net (CPN) for modeling and Prototype Verification System (PVS) for mathematical verification. In order to help flow-through from modeling by CPN to mathematical proof by PVS, a translator has been developed in this work. The combined method has been applied to a protection system function of Wolsong NPP SDS2(Steam Generator Low Level Trip) and found to be promising for further research and applications. 7 refs., 10 figs. (Author)

  19. Application of the lines of protection concept to the HTGR-SC/C

    International Nuclear Information System (INIS)

    1981-09-01

    This study of the application of the line of protection (LOP) concept to high temperature gas-cooled reactors (HTGRs) was motivated by a desire to develop a simple and straightforward HTGR safety concept that embodies many of the more complicated and seemingly conflicting concepts facing nuclear industry safety today. These concepts include: (1) defense in depth; (2) design basis events; (3) core damage events (degraded cores); (4) probabilistic analysis and risk assessment; (5) numerical safety goals; and (6) plant investment protection. The LOP concept described herein attempts to incorporate many of the important principles of each into a cohesive framework which provides an overall logic, meaning, and direction for conducting HTGR design and research activities

  20. Subcomponent vaccine based on CTA1-DD adjuvant with incorporated UreB class II peptides stimulates protective Helicobacter pylori immunity.

    Science.gov (United States)

    Nedrud, John G; Bagheri, Nayer; Schön, Karin; Xin, Wei; Bergroth, Hilda; Eliasson, Dubravka Grdic; Lycke, Nils Y

    2013-01-01

    A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB). The protective efficacy of the selected peptides together with cholera toxin (CT) was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD) that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform.

  1. Comparison of Authorization/Registration/Notification Processes among Biocidal Products, Cosmetics, Plant Protection Products and Human Medicinal Products

    OpenAIRE

    Söyleriz, Yüksel

    2015-01-01

    In this study, comparison of the authorization/registration/notification processes of biocidal products, cosmetics, plant protection products and medicinal products are made and in this respect, the situation in EU is assessed.

  2. Security-by-design approach of the KALIMER 600 SFR plant

    International Nuclear Information System (INIS)

    So, Dong Sup; Lee, Yong Bum

    2012-01-01

    Security measures as well as safety and safeguards measures should be incorporated and addressed early in the design process to enhance the cost effectiveness of a PPS (Physical Protection System). Safety, security, operations, and safeguards design teams and regulators need to be flexible and perform 'trade studies' on the available options. In this paper, SBD (Security by Design) measures in the design phase of the KALIMER 600 SFR (Sodium Cooled Reactor) plant are identified and discussed qualitatively

  3. Foaming in Hanford River Protection Project Waste Treatment Plant LAW Evaporation Processes - FY01 Summary Report

    International Nuclear Information System (INIS)

    Calloway, T.B.

    2002-01-01

    The LAW evaporation processes currently being designed for the Hanford River Protection Project Waste Treatment Plant are subject to foaming. Experimental simulant studies have been conducted in an effort to achieve an effective antifoam agent suitable to mitigate such foaming

  4. Radiation protection aspects of the repair work at Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Bujtas, T.; Nenyei, A.

    2006-01-01

    On the Unit 2 at Paks Nuclear Power Plant accident occurred on 10th April 2003. Thirty fuel assemblies damaged in the cleaning tank installed in the Pit No. 1. Due to the accident casing of the fuel elements and uranium-dioxide pellets inside them damaged. The scratched fuel assemblies and nuclear fuel fragments should be removed and safely deposited. In order to restore the operational condition of the Pit No. 1 a lot of complicated activities with radiation hazard should be implemented. These tasks bring up both technical difficulties and serious radiation protection problems, and it is essential to resolve them in order to reduce radiation exposure of the working personnel and to minimize the amount of off-site radioactive releases.There was a serious incident (An INES level 3 event) at Paks Nuclear Power plant in april 10, 2003. (TRA)

  5. Environmental impact assessment of nuclear desalination plant at KANUPP

    International Nuclear Information System (INIS)

    Sleem, M.

    2010-01-01

    A Nuclear Desalination Demonstration Plant (NDDP) of 1600 m/sup 3//d capacity is being installed at Karachi Nuclear Power Plant (KANUPP). A Nuclear Desalination Plant (NDP) can impact the aquatic environment mainly by subjecting the aquatic life to possible temperature increase and salinity changes in the vicinity of the cooling water and brine discharges. Any wastewater effluent, which will be discharged from the NDDP, may have some adverse effects on the marine life and general environment. In order to protect the environment and comply with the requirement of the Pakistan Environmental Protection Agency (PEPA) an Environmental Impact Assessment (EIA) for the discharged effluent from NDDP was carried out. In the present work baseline study was carried out for project location, climate, water resources, and ecology. Checklist has been prepared for identification of possible environmental impacts of the project and marked as insignificant, small, moderate or major impact. Appropriate mitigation measures have been recommended that can be incorporated into the intended program to minimize environmental impacts identified during the assessment. Specific conclusions of the study and recommendations have also been provided in this paper.

  6. PLANT PROTECTION PRODUCT RESIDUES IN AGRICULTURAL PRODUCTS OF SLOVENE ORIGIN FOUND IN 2008

    Directory of Open Access Journals (Sweden)

    Helena BAŠA ČESNIK

    2012-01-01

    Full Text Available In the year 2008, 166 apple, bean, carrot, cucumber, lettuce, pear, potato and spinach samples from Slovene producers were analysed for plant protection product residues. The samples were analysed for the presence of 158 different active compounds using three analytical methods. In two samples (1.2% exceeded maximum residue levels (MRLs were determined which is better than the results of the monitoring of pesticide residues in the products of plant origin in the 27 European Union, Member States (EU MS and 2 European Free Trade Association (EFTA States: Norway and Iceland in 2008 (2.2%. The most frequently found active substance in agricultural products was dithiocarbamates. Products which contained 4 or more active substances per sample were apples and pears.

  7. Nuclear power plant fire protection: fire detection (subsystems study Task 2)

    International Nuclear Information System (INIS)

    Berry, D.L.

    1977-12-01

    This report examines the adequacy of fire detection in the context of nuclear power plant safety. Topics considered are: (1) establishing area detection requirements, (2) selecting specific detector types, (3) locating and spacing detectors, and (4) performing installation tests and maintenance. Based on a thorough review of fire detection codes and standards and fire detection literature, the report concludes that current design and regulatory guidelines alone are insufficient to ensure satisfactory fire detection system performance. To assure adequate fire detection, this report recommends the use of in-place testing of detectors under conditions expected to occur normally in areas being protected

  8. Physical protection of power reactors

    International Nuclear Information System (INIS)

    Darby, J.L.

    1979-01-01

    Sandia Laboratories has applied a systematic approach to designing physical protection systems for nuclear facilities to commercial light-water reactor power plants. A number of candidate physical protection systems were developed and evaluated. Focus is placed on the design of access control subsystems at each of three plant layers: the protected area perimeter, building surfaces, and vital areas. Access control refers to barriers, detectors, and entry control devices and procedures used to keep unauthorized personnel and contraband out of the plant, and to control authorized entry into vital areas within the plant

  9. USE OF SAPROPHYTIC FUNGI SPECIMENS AS A PLANT PROTECTION AGENTS IN TOMATOE PLANTATION

    Directory of Open Access Journals (Sweden)

    Katarzyna Bandurska

    2015-07-01

    Full Text Available The purpose of this study was to determine the effects of the Trichoderma spp. fungi on the conditions and health of tomato plants. The experiments were conducted in pot cultures and controlled conditions. Commercial formula TRIFENDER containing Trichoderma asperellum spores and isolated from garden soil strain T12 Trichoderma viride were used. In one embodiment, the plants were treated with pathogenic strain of Fusarium sp. that commonly damages crops and against which the whole arsenal of chemicals is used. Preparations obtained from isolated and multiplied fungal cultures were used for the treatment of the above-ground (spraying and under-ground (sprinkling parts of tomatoes. Influence of the Trichoderma fungi was determined by comparing the presence of necrosis on leaves in various groups of cultivated tomatoes compared to control samples. The development of seedlings was checked by measuring the length of plants and the weight of fresh and dry plants. The results demonstrated the protective role of Trichoderma spp. fungi in relation to the Fusarium sp.. Leaves of tomato treated with solutions of saprophytic fungi had a statistically significant lower amount of necrotic changes caused by the pathogen. More effective in this regard was uncommercial isolate of T. viride. Formulation used in the experiments Trifender and isolate T. viride statistically significant influence on the growth and development of the tomato plants as evidenced by increased compared to the control fresh and dry weight of plants.

  10. Fire protection of safe shutdown capability at commercial nuclear power plants

    International Nuclear Information System (INIS)

    Sullivan, K.

    1993-01-01

    The comprehensive industrial safety standards and codes that exist today have evolved from lessons learned through past experience, research results, and improvements in technological capabilities. The current requirements for fire safety features of commercial nuclear power stations operated in the US are a notable example of this practice. Although fire protection has always been an important design requirement, from the aftermath of a serious fire that occurred in 1975 at the Browns Ferry plant, it was learned that the life safety and property protection concerns of the major fire insurance underwriters may not sufficiently encompass nuclear safety issues, particularly with regard to the potential for fire damage to result in the common mode failure of redundant trains of systems, and components important to the safe shutdown of the reactor. Following its investigations into the Browns Ferry fire, the Nuclear Regulatory Commission (NRC) promulgated guidance documents, which ultimately developed into mandatory regulations, necessary to assure the implementation of a fire protection program that would address nuclear safety concerns. The new criteria that evolved, contain prescriptive design features, as well as personnel and administrative requirements the Commission determined to be necessary to provide a defense-in-depth level of protection against the hazards of fire and its associated effects on safety related equipment. These criteria are primarily contained in Appendix R of Title 10 to the Code of Federal Regulations (10 CFR 50). Since 1983, various members of the Department of Nuclear Energy (DNE) at Brookhaven National Laboratory (BNL) have provided technical assistance to the Nuclear Regulatory Commission (NRC) in support of its evaluations of fire protection features implemented at commercial nuclear power stations operated in the US. This paper presents a discussion of the insights gained by the author during his active participation in this area

  11. Subcomponent vaccine based on CTA1-DD adjuvant with incorporated UreB class II peptides stimulates protective Helicobacter pylori immunity.

    Directory of Open Access Journals (Sweden)

    John G Nedrud

    Full Text Available A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB. The protective efficacy of the selected peptides together with cholera toxin (CT was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform.

  12. Development of a methodology for the evaluation of radiation protection performance and management in nuclear power plants

    International Nuclear Information System (INIS)

    Schieber, Caroline; Bataille, Celine; Cordier, Gerard; Delabre, Herve; Jeannin, Bernard

    2008-01-01

    This paper describes a specific methodology adopted by Electricite de France to perform the evaluation of radiation protection performance and management within its 19 nuclear power plants. The results obtained in 2007 are summed up. (author)

  13. NMR analysis of lignins in CAD-deficient plants. Part 1. Incorporation of hydroxycinnamaldehydes and hydroxybenzaldehydes into lignins.

    Science.gov (United States)

    Kim, Hoon; Ralph, John; Lu, Fachuang; Ralph, Sally A; Boudet, Alain M; MacKay, John J; Sederoff, Ronald R; Ito, Takashi; Kawai, Shingo; Ohashi, Hideo; Higuchi, Takayoshi

    2003-01-21

    Peroxidase/H2O2-mediated radical coupling of 4-hydroxycinnamaldehydes produces 8-O-4-, 8-5-, and 8-8-coupled dehydrodimers as has been documented earlier, as well as the 5-5-coupled dehydrodimer. The 8-5-dehydrodimer is however produced kinetically in its cyclic phenylcoumaran form at neutral pH. Synthetic polymers produced from mixtures of hydroxycinnamaldehydes and normal monolignols provide the next level of complexity. Spectral data from dimers, oligomers, and synthetic polymers have allowed a more substantive assignment of aldehyde components in lignins isolated from a CAD-deficient pine mutant and an antisense-CAD-downregulated transgenic tobacco. CAD-deficient pine lignin shows enhanced levels of the typical benzaldehyde and cinnamaldehyde end-groups, along with evidence for two types of 8-O-4-coupled coniferaldehyde units. The CAD-downregulated tobacco also has higher levels of hydroxycinnamaldehyde and hydroxybenzaldehyde (mainly syringaldehyde) incorporation, but the analogous two types of 8-O-4-coupled products are the dominant features. 8-8-Coupled units are also clearly evident. There is clear evidence for coupling of hydroxycinnamaldehydes to each other and then incorporation into the lignin, as well as for the incorporation of hydroxycinnamaldehyde monomers into the growing lignin polymer. Coniferaldehyde and sinapaldehyde (as well as vanillin and syringaldehyde) co-polymerize with the traditional monolignols into lignins and do so at enhanced levels when CAD-deficiency has an impact on the normal monolignol production. The implication is that, particularly in angiosperms, the aldehydes behave like the traditional monolignols and should probably be regarded as authentic lignin monomers in normal and CAD-deficient plants.

  14. beta-aminobutyric acid protects Brassica napus plants from infection by Leptosphaeria maculans. Resistance induction or a direct antifungal effect?

    Czech Academy of Sciences Publication Activity Database

    Šašek, Vladimír; Nováková, Miroslava; Dobrev, Petre; Valentová, O.; Burketová, Lenka

    2012-01-01

    Roč. 133, č. 1 (2012), s. 279-289 ISSN 0929-1873 R&D Projects: GA ČR GA522/08/1581; GA MZe QH72117 Institutional research plan: CEZ:AV0Z50380511 Keywords : Antimicrobial * BTH * Gene expression Subject RIV: GF - Plant Pathology, Vermin, Weed, Plant Protection Impact factor: 1.610, year: 2012

  15. EFSA Guidance Document on the risk assessment of plant protection products on bees (Apis mellifera, Bombus spp. and solitary bees)

    NARCIS (Netherlands)

    Arnold, G.; Boesten, J.J.T.I.; Clook, M.

    2013-01-01

    The Guidance Document is intended to provide guidance for notifiers and authorities in the context of the review of plant protection products (PPPs) and their active substances under Regulation (EC) 1107/2009. The scientific opinion on the science behind the development of a risk assessment of plant

  16. Is an ecosystem services-based approach developed for setting specific protection goals for plant protection products applicable to other chemicals?

    Science.gov (United States)

    Maltby, Lorraine; Jackson, Mathew; Whale, Graham; Brown, A Ross; Hamer, Mick; Solga, Andreas; Kabouw, Patrick; Woods, Richard; Marshall, Stuart

    2017-02-15

    Clearly defined protection goals specifying what to protect, where and when, are required for designing scientifically sound risk assessments and effective risk management of chemicals. Environmental protection goals specified in EU legislation are defined in general terms, resulting in uncertainty in how to achieve them. In 2010, the European Food Safety Authority (EFSA) published a framework to identify more specific protection goals based on ecosystem services potentially affected by plant protection products. But how applicable is this framework to chemicals with different emission scenarios and receptor ecosystems? Four case studies used to address this question were: (i) oil refinery waste water exposure in estuarine environments; (ii) oil dispersant exposure in aquatic environments; (iii) down the drain chemicals exposure in a wide range of ecosystems (terrestrial and aquatic); (iv) persistent organic pollutant exposure in remote (pristine) Arctic environments. A four-step process was followed to identify ecosystems and services potentially impacted by chemical emissions and to define specific protection goals. Case studies demonstrated that, in principle, the ecosystem services concept and the EFSA framework can be applied to derive specific protection goals for a broad range of chemical exposure scenarios. By identifying key habitats and ecosystem services of concern, the approach offers the potential for greater spatial and temporal resolution, together with increased environmental relevance, in chemical risk assessments. With modifications including improved clarity on terminology/definitions and further development/refinement of the key concepts, we believe the principles of the EFSA framework could provide a methodical approach to the identification and prioritization of ecosystems, ecosystem services and the service providing units that are most at risk from chemical exposure. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights

  17. PRN 2007-2: Guidance on Small-Scale Field Testing and Low-level Presence in Food of Plant-Incorporated Protectants (PIPs)

    Science.gov (United States)

    This notice clarifies how EPA ensures the safety of residues of PIPs possibly present in food or feed and when a tolerance or tolerance exemption would be required for field tests for biotechnology-derived food and feed crop plants containing PIPs.

  18. Extensions and renovations of reactor protection systems

    International Nuclear Information System (INIS)

    Hellmerichs, K.

    1985-01-01

    Increase of requirements by the authorities as to the design of reactor protection systems affected in the last years not only plans being under construction, but also resulted in partly spacious extensions and renovations. While working on the extensions and renovations a lot of problems arose: far-reaching performance of newest guidelines and rules in spite of old plant concepts; partly higher degree of redundancy requirements of the new systems in contrast to the present systems; use of present safeguard systems for new accident countermeasures; designation of priorities between present and new functions, especially in view of fault behaviour of present systems; adaptation of the new I and C equipment to the present signalisation-, operation- and information-arrangements under consideration of the present operational philosophy; spatial incorporation of new equipments; construction as to time without expanding of the planned refuelling phases. Because the KWU has planned and constructed such alterations in nearly 10 plants a lot of experience has been gathered. (author)

  19. Survey results of corroding problems at biological treatment plants, Stage II Protection of concrete - State of the Art

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Ylva (CBI, Boraas (Sweden)); Henriksson, Gunilla (SP, Boraas (Sweden))

    2011-07-01

    A pilot study on the degradation and corrosion of concrete in biological treatment plants was conducted in 2009/2010 in a Waste Refinery Project WR-27 'Survey results of corroding problems at biological treatment plants'. The results showed that the concrete does not have sufficient resistance in the current aggressive plant environment. Furthermore, it is stated that some form of surface protection system is needed to ensure the good performance of concrete constructions, and that the system must withstand the aggressive environment and the traffic that occurs on site. Consequently, a new study was proposed in order to develop specifications for surface protection of concrete in aggressive food waste environments. Results from that study are presented in this report. The report includes various types of waterproofing/protection coating for concrete in biological treatment plants. A number of proposals from the industry are presented in the light of results from project WR-27, i.e., the materials must, among other things, withstand the aggressive leachate from waste food at temperatures up to 70 deg C, and some degree of wear. Some systems are compared in terms of technical material properties as reported by the manufacturer. It turns out that different testing methods were used, and the test results are thus generally not directly comparable. A proposal for a test program has been developed, focusing on chemical resistance and wear resistance. A test solution corresponding to leachate is specified. Laboratory tests for verification of the proposed methodology and future requirements are proposed, as well as test sites and follow-up in the field

  20. Physicochemical and Antioxidant Properties of Chitosan Films Incorporated with Cinnamon Oil

    Directory of Open Access Journals (Sweden)

    Marco A. López-Mata

    2015-01-01

    Full Text Available Chitosan films (CF with cinnamon bark oil (CO incorporated at 0% (control, 0.25%, 0.5%, and 1.0% v/v were prepared by an emulsion method. The films were characterized based on their physical properties (solubility, water vapor permeability, optical property, and microstructure and antioxidant properties (DPPH, ABTS, and its protective effects on human erythrocytes. The results showed that the incorporation of 0.5 and 1.0% of CO into the CF significantly decreased its solubility to 22% of the control (p<0.05. The water vapor permeability of the CF-CO was significantly reduced to 40% with low concentrations of CO (0.25% incorporated into the CF. In general, the films presented a yellow coloration and an increase in transparency with the incorporation of CO into the CF. It was also observed that the incorporation of CO increased the antioxidant activity between 6.0-fold and 14.5-fold compared to the control, and the protective capacity against erythrocyte hemolysis increased by as much as 80%.

  1. Surface treatments for material protection in nuclear power plants

    International Nuclear Information System (INIS)

    De, P.K.; Gadiyar, H.S.

    1987-01-01

    The paper highlights some of the surface treatment methods used in nuclear power plants to improve their performance. The corrosion resistance of zirconium alloys results from the formation of an adherent and protective film of ZrO 2 . Graphite coating of zircaloy-2 cladding minimizes the susceptibility to environmental induced cracking. Magnetite formation during the hot conditioning operation improves the corrosion resistance of carbon steel as well as controls the spread of radioactivity. It has been illustrated how the surface treatment is helpful for redistributing residual stress to facilitate conversion of tensile stress to compressive stress to mitigate failures due to stress corrosion and fatigue corrosion. Inhibitors and passivators can modify the surface conditions (in situ) of condenser tubes and cooling water systems. These aspects have been dealt in the text of the paper. (author). 8 refs., 3 figures

  2. The adhesion characteristics of protective coating materials for the containment structure in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Sang-Kook; Shin, Jae-Chul

    2003-01-01

    Protective coating materials used in the containment structures should be durable for the designed 30 to 40 year lifetime of a nuclear power plant. At the present, these materials have not yet been developed. Therefore it is very important to keep the durability of the protective coating materials through persistent maintenance, and in order to achieve this, understanding the adhesion characteristics of the coating materials is of utmost importance. Therefore, this study attempts to find any methods for durability maintenance of these protective coating materials. To accomplish these aims, this study applied an experimental deterioration environment condition relevant to Loss of Coolant Accident (LOCA) and Main Steam Line Break (MSLB), categorized as of Design Basis Accident (DBA), onto steel liner plate specimens covered with protective coating materials. Adhesion tests were performed on these deteriorated coating materials to characterize the physical properties and through these tests, the quantitative adhesion characteristics according to the history of deterioration environment were found

  3. Verification Results of Safety-grade Optical Modem for Core Protection Calculator (CPC) in Korea Standard Nuclear Power Plant (KSNP)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jangyeol; Son, Kwangseop; Lee, Youngjun; Cheon, Sewoo; Cha, Kyoungho; Lee, Jangsoo; Kwon, Keechoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    We confirmed that the coverage criteria for a safety-grade optical modem of a Core Protection Calculator is satisfactory using a traceability analysis matrix between high-level requirements and lower-level system test case data set. This paper describes the test environment, test components and items, a traceability analysis, and system tests as a result of system verification and validation based on Software Requirement Specifications (SRS) for a safety-grade optical modem of a Core Protection Calculator (CPC) in a Korea Standard Nuclear Power Plant (KSNP), and Software Design Specifications (SDS) for a safety-grade optical modem of a CPC in a KSNP. All tests were performed according to the test plan and test procedures. Functional testing, performance testing, event testing, and scenario based testing for a safety-grade optical modem of a Core Protection Calculator in a Korea Standard Nuclear Power Plant as a thirty-party verifier were successfully performed.

  4. Radiation protection in Baden-Wuerttemberg

    International Nuclear Information System (INIS)

    1978-01-01

    The tasks of radiation protection and nuclear safety to be looked after by the land Baden-Wuerttemberg consist essentially in licensing and control activities carried out by the Federal Government. With regard to radiation protection the focal points of the second medium-term programme of the Laender Government Baden-Wuerttemberg are: 1. the technical development plan 'power plant sites', 2. construction of nuclear power plants in the borderline areas of neighbouring foreign countries, 3. disposal of radioactive waste, 4. pollution protection measures against nuclear power plants, 5. safety measures when dealing with radioactive materials outside nuclear power plants. (GL) [de

  5. Early incorporation and distribution of 14C-photosynthates after 14C-feeding for a brief period in tea plant

    International Nuclear Information System (INIS)

    Hakamata, Katsuhiro

    1981-01-01

    In order to clarify the early incorporation and distribution of 14 C-photosynthetic products in tea plants after 14 C-feeding for a brief period, 14 C-tracer experiments were performed, using the winter leaves, first crop shoots and young tea plants of a cultivar, Yabukita. As the results of the experiment on leaf disks by 14 C-Feeding for one minute, the 14 C-activity in the ethanol soluble fraction distributed in the anionic, cationic and neutral fractions in this order. When the time of feeding was extended to 10 min, the distribution in the cationic fraction decreased, and that in the neutral fraction increased. In the experiment on shoots, after the end of 10 min assimulation, the 14 C-activity in the ethanol soluble fraction distributed in the neutral, cationic and anionic fractions in this order. In course of time, the distribution in the cationic and anionic fractions decreased, and that in the neutral fraction increased. As the results of 14 C-feeding to young tea plants for 2.5 hours, 70 - 95% of the 14 C-activity in the ethanol soluble fraction distributed in the neutral fraction. Sucrose seemed to be the primary and early product of photosynthesis, and might be the principal carbohydrate form of translocation and reserve in tea plants. Raffinose and stachyose played almost the same role as sucrose. (Kako, I.)

  6. Radiation protection and environmental monitoring in the area of the Asse shaft plant

    International Nuclear Information System (INIS)

    Meyer, H.; Mueller-Lyda, I.

    1990-08-01

    Personnel monitoring has been carried through in compliance with the Radiation Protection Ordinance. Environmental monitoring including measurement of local doses, local dose rates, and airborne radioactivity in the shaft has been made according to the provisions for radiation protection at the place of work. Maximum permissible personal doses or activity levels for occupationally exposed persons have not been exceeded in the reporting period. Exhaust air monitoring detected the nuclides H-3, C-14, Pb-210, and the short-lived daughter products of Rn-222 and Rn-220. The activity concentrations in the environment, determined from the measured annual release values, for some part have been lower than the average of natural concentrations of said nuclides. The radiation exposure due to emissions, measured at the least favourable point in the environment, has been far below the limits set by the Radiation Protection Ordinance. In conclusion: The radiation exposure of the personnel and of the population in the area of the Asse shaft plant due to the storage of radioactive is low, compared to the natural radiation exposure. (orig.) [de

  7. Radiation protection and environmental monitoring in the area of the Asse shaft plant

    International Nuclear Information System (INIS)

    Mueller-Lyda, I.; Meyer, H.

    1989-06-01

    Personnel monitoring has been carried through in compliance with the Radiation Protection Ordinance. Environmental monitoring including measurement of local doses, local dose rates, and airborne radioactivity in the shaft has been made according to the provisions for radiation protection at the place of work. Maximum permissible personal doses or activity levels for occupationally exposed persons have not been exceeded in the reporting period. Exhaust air monitoring detected the nuclides H-3, C-14, Pb-210, and the short-lived daughter products of Rn-222 and Rn-220. The activity concentrations in the environment, determined from the measured annual release values, for some part have been lower than the average of natural concentrations of said nuclides. The radiation exposure due to emissions, measured at the least favourable point in the environment, has been far below the limits set by the Radiation Protection Ordinance. In conclusion: The radiation exposure of the personnel and of the population in the area of the Asse shaft plant due to the storage of radioactive is low, compared to the natural radiation exposure. (orig.) [de

  8. [Study on standards for safe and health-protective zone in firework plant].

    Science.gov (United States)

    Wu, Y; Wang, Q; Shi, J; Shao, Q

    1999-03-30

    A retrospective investigation on technology and situation in the production of fireworks, the cause and hazard consequences of accidents in blossom firework enterprises was carried out. The risk factors and their origins, the potential effects on surrounding environments and residents, the manufacture processes producing special potential energy in these enterprises were summarized and assessed. In addition, the consequences of explosive fire accidents were assessed retrospectively by the principle of explosion mechanics and Hopkinson Scaling Law. The safe and health-protective zone of the blossom firework plant was suggested.

  9. Design of reactor protection systems for HTR plants generating electric power and process heat problems and solutions

    International Nuclear Information System (INIS)

    Craemer, B.; Dahm, H.; Spillekothen, H.G.

    1982-06-01

    The design basis of the reactor protection system (RPS) for HTR plants generating process heat and electric power is briefly described and some particularities of process heat plants are indicated. Some particularly important or exacting technical measuring positions for the RPS of a process heat HTR with 500 MWsub(th) power (PNP 500) are described and current R + D work explained. It is demonstrated that a particularly simple RPS can be realized in an HTR with modular design. (author)

  10. Study of the Effect of Sol pH and Nanoclay Incorporation on the Corrosion Protection Performance of a Silane Sol-Gel Coating

    Directory of Open Access Journals (Sweden)

    Najmeh Asadi

    2014-06-01

    Full Text Available This work is aimed to evaluate the role of nanoclay in the protective performance of an eco-friendly silane sol-gel layer applied on mild steel substrate in 0.1M sodium chloride solution. At the first step, the effect of pH of the silane solution, consisting of a mixture of γ-glycidoxypropiltrimethoxysilane and methyltriethoxysilane and tetraethoxysilane, on the coating performance was evaluated through electrochemical noise measurements. The values of characteristic charge as a parameter extracted from shot noise theory revealed that the sol pH determining the rate of hydrolysis can play an important role in the corrosion protection behavior of silane coatings. Then, the influence of clay nanoparticles on the corrosion protective performance of the hybrid silane film was studied through taking advantage of electrochemical techniques, including electrochemical impedance spectroscopy and polarization curves, as well as surface analysis methods. The obtained electrochemical data including the values of charge transfer resistance, coating resistance, low frequency impedance and corrosion current density showed that the silane sol gel film in the presence of clay nanoparticles can present an improved corrosion protection. The behavior was connected to an enhancement in the coating barrier properties. Moreover, FESEM and water contact angle confirmed the higher reticulation in case of the coating incorporating nanoclay.

  11. Assessing plant protection practices using pressure indicator and toxicity risk indicators: analysis of therelationship between these indicators for improved risk management, application in viticulture.

    Science.gov (United States)

    Oussama, Mghirbi; Kamel, Ellefi; Philippe, Le Grusse; Elisabeth, Mandart; Jacques, Fabre; Habiba, Ayadi; Jean-Paul, Bord

    2015-06-01

    The excessive use of plant protection products (PPPs) has given rise to issues of public and environmental health because of their toxicity. Reducing the use of toxic PPPs and replacing them with products that are less toxic for human health and the environment have become socially, environmentally and economically indispensable. In this article, we assess the plant protection practices of a small group of winegrowers practicing "integrated agriculture" in the south of France, in order to measure the benefit of using toxicity risk indicators as a decision-support tool for different players in land management. An analysis of plant protection practices using indicators of the risk to operator health and the environment (IRSA, IRTE), together with a frequency-of-treatment indicator (TFI), enabled us to (i) show the variability of these indicators depending on the production system and farmers' pesticide use strategies and (ii) calculate correlations between these indicators. This analysis of plant protection practices at different scales (farm, field), carried out in collaboration with the growers, enabled us to perform an initial validation of decision-support tools for determining risk management strategies regarding the use of pesticides.

  12. Design concepts for the reactor protection and control process instrumentation digital upgrade project at the Donald C. Cook Nuclear Plant units 1 and 2

    International Nuclear Information System (INIS)

    Carruth, R.C.; Sotos, W.G.

    1996-01-01

    As the nation's nuclear power plants age, the need to consider upgrading of their electronic protection and control systems becomes more urgent. Hardware obsolescence and mechanical wear out resulting from frequent calibration and surveillance play a major role in defining their useful life. At Cook Nuclear Plant, a decision was made to replace a major portion of the plant's protection and control systems with newer technology. This paper describes the engineering processes involved in this successful upgrade and explains the basis for many decisions made while performing the digital upgrade

  13. 78 FR 76317 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Science.gov (United States)

    2013-12-17

    ...-FF08RSRC00] Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/ Fish Screen Facility Protection... and Wildlife (CDFW), announce that the record of decision (ROD) for the Llano Seco Riparian Sanctuary...: www.fws.gov/refuge/sacramento river/ and http://www.riverpartners.org/where-we-work/sanctuary...

  14. Conceptual Framework for Physical Protection Against Sabotage Considering Plant-specific Radiological Consequences

    International Nuclear Information System (INIS)

    Lee, Joung Hoon; Yu, Dong Han

    2010-01-01

    According to the Generation IV (Gen IV) Technology Roadmap, Gen IV nuclear energy systems (NESs) should highlight proliferation resistance and physical protection (PR and PP) as one of the four goals along with sustainability, safety and reliability, and economics. Especially, physical protection (PP) is the typical important characteristic of an NES that impedes the theft of materials suitable for nuclear explosives or radiation dispersal devices (RDD) and the sabotage of facilities and transportation by subnation entities and other non-Host State adversaries. These two subjects have been studied separately. Proliferation is commonly considered as an international concern and the past work on the PR assessments can be found. On the other hands, PP is regarded as a State security concern, much of which is classified and facility-dependent. Recently, more concern has been focused on the PP design and regulation because of rapid environment changes including radiological consequences by internal sabotage and nuclear terrorism by RDDs. The current PP Regulation has been applied intensively to the existing nuclear facilities and could be a possible guidance for the future GEN-IV NESs. This paper first reviews the IAEA guide document, INFCIRC/225, which was accepted as the standard international guideline in the physical protection area. It has been updated several times up to now, and is undergoing another revision. The paper introduces current substantial changes in the document regarding PP including the national nuclear security and sabotage in the nuclear facilities. Then, it presents a conceptual framework for physical protection against sabotage considering plant-specific radiological consequence after malicious acts within certain vital areas. The framework combines the newly developed method of vital area identification, the current PSA level 2 works, and physical protection concepts. This would help to improve a design concept of new physical protection

  15. Conceptual Framework for Physical Protection Against Sabotage Considering Plant-specific Radiological Consequences

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joung Hoon; Yu, Dong Han [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2010-10-15

    According to the Generation IV (Gen IV) Technology Roadmap, Gen IV nuclear energy systems (NESs) should highlight proliferation resistance and physical protection (PR and PP) as one of the four goals along with sustainability, safety and reliability, and economics. Especially, physical protection (PP) is the typical important characteristic of an NES that impedes the theft of materials suitable for nuclear explosives or radiation dispersal devices (RDD) and the sabotage of facilities and transportation by subnation entities and other non-Host State adversaries. These two subjects have been studied separately. Proliferation is commonly considered as an international concern and the past work on the PR assessments can be found. On the other hands, PP is regarded as a State security concern, much of which is classified and facility-dependent. Recently, more concern has been focused on the PP design and regulation because of rapid environment changes including radiological consequences by internal sabotage and nuclear terrorism by RDDs. The current PP Regulation has been applied intensively to the existing nuclear facilities and could be a possible guidance for the future GEN-IV NESs. This paper first reviews the IAEA guide document, INFCIRC/225, which was accepted as the standard international guideline in the physical protection area. It has been updated several times up to now, and is undergoing another revision. The paper introduces current substantial changes in the document regarding PP including the national nuclear security and sabotage in the nuclear facilities. Then, it presents a conceptual framework for physical protection against sabotage considering plant-specific radiological consequence after malicious acts within certain vital areas. The framework combines the newly developed method of vital area identification, the current PSA level 2 works, and physical protection concepts. This would help to improve a design concept of new physical protection

  16. Micro processors for plant protection

    International Nuclear Information System (INIS)

    McAffer, N.T.C.

    1976-01-01

    Micro computers can be used satisfactorily in general protection duties with economic advantages over hardwired systems. The reliability of such protection functions can be enhanced by keeping the task performed by each protection micro processor simple and by avoiding such a task being dependent on others in any substantial way. This implies that vital work done for any task is kept within it and that any communications from it to outside or to it from outside are restricted to those for controlling data transfer. Also that the amount of this data should be the minimum consistent with satisfactory task execution. Technology is changing rapidly and devices may become obsolete and be supplanted by new ones before their theoretical reliability can be confirmed or otherwise by field service. This emphasises the need for users to pool device performance data so that effective reliability judgements can be made within the lifetime of the devices. (orig.) [de

  17. Incorporation of severe accidents in the licensing of nuclear power plants

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout; Rabello, Sidney Luiz

    2011-01-01

    Severe accidents are the result of multiple faults that occur in nuclear power plants as a consequence from the combination of latent failures and active faults, such as equipment, procedures and operator failures, which leads to partial or total melting of the reactor core. Regardless of active and latent failures related to the plant management and maintenance, aspects of the latent failures related to the plant design still remain. The lessons learned from the TMI accident in the U.S.A., Chernobyl in the former Soviet Union and, more recently, in Fukushima, Japan, suggest that severe accidents must necessarily be part of design-basis of nuclear power plants. This paper reviews the normative basis of the licensing of nuclear power plants concerning to severe accidents in countries having nuclear power plants under construction or in operation. It was addressed not only the new designs of nuclear power plants in the world, but also the design changes in plants that are in operation for decades. Included in this list are the Brazilian nuclear power plants, Angra-1, Angra-2, and Angra-3. This paper also reviews the current status of licensing in Brazil and Brazilian standards related to severe accidents. It also discusses the impact of severe accidents in the emergency plans of nuclear power plants. (author)

  18. Incorporation of severe accidents in the licensing of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Marco Antonio Bayout; Rabello, Sidney Luiz, E-mail: bayout@cnen.gov.b, E-mail: sidney@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN) Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Severe accidents are the result of multiple faults that occur in nuclear power plants as a consequence from the combination of latent failures and active faults, such as equipment, procedures and operator failures, which leads to partial or total melting of the reactor core. Regardless of active and latent failures related to the plant management and maintenance, aspects of the latent failures related to the plant design still remain. The lessons learned from the TMI accident in the U.S.A., Chernobyl in the former Soviet Union and, more recently, in Fukushima, Japan, suggest that severe accidents must necessarily be part of design-basis of nuclear power plants. This paper reviews the normative basis of the licensing of nuclear power plants concerning to severe accidents in countries having nuclear power plants under construction or in operation. It was addressed not only the new designs of nuclear power plants in the world, but also the design changes in plants that are in operation for decades. Included in this list are the Brazilian nuclear power plants, Angra-1, Angra-2, and Angra-3. This paper also reviews the current status of licensing in Brazil and Brazilian standards related to severe accidents. It also discusses the impact of severe accidents in the emergency plans of nuclear power plants. (author)

  19. Protective effects of plant seed extracts against amyloid β-induced neurotoxicity in cultured hippocampal neurons.

    Science.gov (United States)

    Okada, Yoshinori; Okada, Mizue

    2013-04-01

    Alzheimer's disease (AD) is characterized by large deposits of amyloid β (Aβ) peptide. Aβ is known to increase reactive oxygen species (ROS) production in neurons, leading to cell death. In this study, we screened 15 plant seeds' aqueous extracts (PSAE) for inhibitory effects on Aβ (25-35)-induced cell death using hippocampus neurons (HIPN). Fifteen chosen plants were nine medical herbs (Japanese honeywort, luffa, rapeseed, Chinese colza, potherb mustard, Japanese radish, bitter melon, red shiso, corn, and kaiware radish) and six general commercial plants (common bean, komatsuna, Qing geng cai, bell pepper, kale, and lettuce). PSAE were measured for total phenolic content (TPC) with the Folin-Ciocalteu method, and the 2-diphenyl-1-picryl-hydrazyl (DPPH) radical scavenging effect of each seed extract was measured. To find a protectant against Aβ-induced oxidative stress, we screened 15 PSAE using a 2', 7'-dichlorofluorescein diacetate assay. To further unravel the anti-inflammatory effects of PSAE on Aβ-induced inflammation, PSAE were added to HIPN. The neuroprotective effects of the PSAE were evaluated by Cell Counting Kit-8 assay, measuring the cell viability in Aβ-induced HIPN. TPC of 15 PSAE was in the range of 0.024-1.96 mg of chlorogenic acid equivalents/gram. The aqueous extracts showed antioxidant activities. Furthermore, intracellular ROS accumulation resulting from Aβ treatment was reduced when cells were treated with some PSAE. Kale, bitter melon, kaiware radish, red shiso, and corn inhibited tumor necrosis factor-alpha secretion by the Aβ-stimulated neurons and all samples except Japanese honeywort showed enhancement of cell survival. From these results, we suggest that some plant seed extracts offer protection against Aβ-mediated cell death.

  20. The System 80+ Standard Plant design control document. Volume 15

    International Nuclear Information System (INIS)

    1997-01-01

    This Design Control Document (DCD) is a repository of information comprising the System 80+trademark Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ''Tier 1''] and the Approved Design Material (ADM) [i.e., ''Tier 2''] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume contains all five parts of section 12 (Radiation Protection) of the ADM Design and Analysis. Topics covered are: ALARA exposures; radiation sources; radiation protection; dose assessment; and health physics program. All six parts and appendices A and B for section 13 (Conduct of Operations) of the ADM Design and Analysis are also contained in this volume. Topics covered are: organizational structure; training program; emergency planning; review and audit; plant procedures; industrial security; sabotage protection (App 13A); and vital equipment list (App 13B)

  1. Application of radioisotopes in plant protection

    International Nuclear Information System (INIS)

    Pothiraj, G.; Pavani, Lalitha; Allimuthu, Elangovan; Yadav, Ranjeet Singh

    2017-01-01

    There are concerns that continuous uses of pesticides have negative impacts on the environment and it also results in development of resistance against pesticides in many insect species. Radioactive exposure improves quality and productivity of agricultural products along with insect, pest and disease management. They are helpful in study of optimum utilization of insecticides and pesticides in cultivated crops without harmful effects to plants and other living organisms. The control of plant virus diseases is one of the greatest problems of our day. Aphids feeding on plants containing 32 P become radioactive and retain the label for some weeks which helps in monitoring their movement. Sterile Insect Technique (SIT) proposed by Knipling in 1955, relies on application of ionizing radiation as a means to effectively sterilize male insects without affecting their ability to function in the field and successfully mate with wild female insects. This technique involves release of large numbers of sterile male insects of the target species in the field crop. With relevance to plant pathogens, radioisotopes are used to measure the spread of the plant diseases. (author)

  2. Occupational Radiological Protection Principles and Criteria for Designing New Nuclear Power Plants

    International Nuclear Information System (INIS)

    2010-01-01

    Global demand for electricity continues to grow and numerous new nuclear power plants (NPPs) are being planned or constructed in NEA member countries. Most of these new NPPs will be of the third generation, and will be designed for as long as 80 years of operation. The successful design, construction and operation of these plants will depend broadly on appropriately implementing the lessons from experience accumulated to date. This case study introduces a policy and technical framework that may be used when formulating technical assistance and guidance for senior managers of NPPs, designers, manufacturers, contractors and authorities responsible for regulating occupational radiation exposure. It is aimed in particular at assisting design and license assessments of new NPPs. Although not targeting the needs of countries introducing nuclear power for the first time, this case study can also provide valuable input on occupational radiological protection issues for the implementation of new nuclear energy programmes

  3. International network on incorporation of ageing effects into PSA

    International Nuclear Information System (INIS)

    Kirchsteiger, C.; Patrik, M.

    2006-01-01

    This paper describes the background and status of a new International Network on ''Incorporating Ageing Effects into Probabilistic Safety Assessment''. The Joint Research Centre (JRC) of the European Commission organized in September 2004 the kickoff meeting of this Network at JRC's Institute for Energy in Petten, Netherlands, with the aims to open the APSA Network, to start discussion of ageing issues in relation to incorporating ageing effects into PSA tools and to come to consensus on objectives and work packages of the Network, taking into account the specific expectations of potential Network partners. The presentations and discussions at the meeting confirmed the main conclusion from the previously organized PSAM 7 pre-conference workshop on ''Incorporating PSA into Ageing Management'', Budapest, June 2004, namely that incorporating ageing effects into PSA seems to be more and more a hot topic particularly for risk assessment and ageing management of nuclear power plants operating at advanced age (more than 25-30 years) and for the purpose of plant life extension. However, it also appeared that, especially regarding the situation in Europe, at present there are several on-going feasibility or full studies in this area, but not yet a completed Ageing PSA leading to applications. The project's working method is a NETWORK of operators, industry, research, academia and consultants with an active interest in the area (physical networking via a series of workshops and virtual networking via the Internet). The resulting knowledge should help PSA developers and users to incorporate the effects of equipment ageing into current PSA tools and models, to identify and/or develop most effective corresponding methods, to focus on dominant ageing contributors and components and to promote the use of PSA for ageing management of Nuclear Power Plants. (orig.)

  4. Incorporation of epidemiological findings into radiation protection standards.

    Science.gov (United States)

    Goldsmith, J R

    In standard setting there is a tendency to use data from experimental studies in preference to findings from epidemiological studies. Yet the epidemiological studies are usually the first and at times the only source of data on such critical effects as cancer, reproductive failure, and chronic cardiac and cardiovascular disease in exposed humans. A critique of the protection offered by current and proposed standards for ionizing and non-ionizing radiation illustrates some of the problems. Similar problems occur with water and air pollutants and with occupational exposures of many types. The following sorts of problems were noted: (a) Consideration of both thermal and non-thermal effects especially of non-ionizing radiation. (b) Interpretation of non-significant results as equivalent to no effect. (c) Accepting author's interpretation of a study, rather than examining its data independently for evidence of hazard. (d) Discounting data on unanticipated effects because of poor fit to preconceptions. (e) Dependence on threshold assumptions and demonstrations of dose-response relationships. (f) Choice of insensitive epidemiological indicators and procedures. (g) Consideration of each study separately, rather than giving weight to the conjunction of evidence from all available studies. These problems may be minimized by greater involvement of epidemiologists and their professional organizations in decisions about health protection.

  5. Companion Protease Inhibitors for the In Situ Protection of Recombinant Proteins in Plants.

    Science.gov (United States)

    Robert, Stéphanie; Jutras, Philippe V; Khalf, Moustafa; D'Aoust, Marc-André; Goulet, Marie-Claire; Sainsbury, Frank; Michaud, Dominique

    2016-01-01

    We previously described a procedure for the use of plant protease inhibitors as "companion" accessory proteins to prevent unwanted proteolysis of clinically useful recombinant proteins in leaf crude protein extracts (Benchabane et al. Methods Mol Biol 483:265-273, 2009). Here we describe the use of these inhibitors for the protection of recombinant proteins in planta, before their extraction from leaf tissues. A procedure is first described involving inhibitors co-expressed along-and co-migrating-with the protein of interest in host plant cells. An alternative, single transgene scheme is then described involving translational fusions of the recombinant protein and companion inhibitor. These approaches may allow for a significant improvement of protein steady-state levels in leaves, comparable to yield improvements observed with protease-deficient strains of less complex protein expression hosts such as E. coli or yeasts.

  6. Computer Security: Protect your plant: a "serious game" about control system cyber-security

    CERN Multimedia

    Stefan Lueders, Computer Security Team

    2015-01-01

    Control system cyber-security is attracting increasing attention: from cybercriminals, from the media and from security researchers.   After the legendary “Stuxnet” attacks of 2010 against an Iranian uranium enrichment plant, the infiltration of Saudi Aramco in 2012, and most recently the hacking of German blast furnaces, we should be prepared. Just imagine what would happen if hackers turned off the lights in Geneva and the Pays-de-Gex for a month? (“Hacking control systems, switching lights off!"). Or if attackers infiltrated CERN’s accelerator or experiment control systems and stopped us from pursuing our core business: delivering beams and recording particle collisions (“Hacking control systems, switching... accelerators off?"). Now you can test your ability to protect an industrial plant against cyber-threats! The Computer Security Team, in collaboration with Kaspersky Lab, is organising a so-...

  7. Phosphorus supply, arbuscular mycorrhizal fungal species, and plant genotype impact on the protective efficacy of mycorrhizal inoculation against wheat powdery mildew.

    Science.gov (United States)

    Mustafa, G; Randoux, B; Tisserant, B; Fontaine, J; Magnin-Robert, M; Lounès-Hadj Sahraoui, A; Reignault, Ph

    2016-10-01

    A potential alternative strategy to chemical control of plant diseases could be the stimulation of plant defense by arbuscular mycorrhizal fungi (AMF). In the present study, the influence of three parameters (phosphorus supply, mycorrhizal inoculation, and wheat cultivar) on AMF protective efficiency against Blumeria graminis f. sp. tritici, responsible for powdery mildew, was investigated under controlled conditions. A 5-fold reduction (P/5) in the level of phosphorus supply commonly recommended for wheat in France improved Funneliformis mosseae colonization and promoted protection against B. graminis f. sp. tritici in a more susceptible wheat cultivar. However, a further decrease in P affected plant growth, even under mycorrhizal conditions. Two commercially available AMF inocula (F. mosseae, Solrize®) and one laboratory inoculum (Rhizophagus irregularis) were tested for mycorrhizal development and protection against B. graminis f. sp. tritici of two moderately susceptible and resistant wheat cultivars at P/5. Mycorrhizal levels were the highest with F. mosseae (38 %), followed by R. irregularis (19 %) and Solrize® (SZE, 8 %). On the other hand, the highest protection level against B. graminis f. sp. tritici was obtained with F. mosseae (74 %), followed by SZE (58 %) and R. irregularis (34 %), suggesting that inoculum type rather than mycorrhizal levels determines the protection level of wheat against B. graminis f. sp. tritici. The mycorrhizal protective effect was associated with a reduction in the number of conidia with haustorium and with an accumulation of polyphenolic compounds at B. graminis f. sp. tritici infection sites. Both the moderately susceptible and the most resistant wheat cultivar were protected against B. graminis f. sp. tritici infection by F. mosseae inoculation at P/5, although the underlying mechanisms appear rather different between the two cultivars. This study emphasizes the importance of taking into account the considered

  8. Quantitative Resistance to Plant Pathogens in Pyramiding Strategies for Durable Crop Protection

    Directory of Open Access Journals (Sweden)

    Marie-Laure Pilet-Nayel

    2017-10-01

    Full Text Available Quantitative resistance has gained interest in plant breeding for pathogen control in low-input cropping systems. Although quantitative resistance frequently has only a partial effect and is difficult to select, it is considered more durable than major resistance (R genes. With the exponential development of molecular markers over the past 20 years, resistance QTL have been more accurately detected and better integrated into breeding strategies for resistant varieties with increased potential for durability. This review summarizes current knowledge on the genetic inheritance, molecular basis, and durability of quantitative resistance. Based on this knowledge, we discuss how strategies that combine major R genes and QTL in crops can maintain the effectiveness of plant resistance to pathogens. Combining resistance QTL with complementary modes of action appears to be an interesting strategy for breeding effective and potentially durable resistance. Combining quantitative resistance with major R genes has proven to be a valuable approach for extending the effectiveness of major genes. In the plant genomics era, improved tools and methods are becoming available to better integrate quantitative resistance into breeding strategies. Nevertheless, optimal combinations of resistance loci will still have to be identified to preserve resistance effectiveness over time for durable crop protection.

  9. Open gas exchange system for simultaneous determination of the apparent CO2 assimilation by means of URAS technique and incorporation of 14C into plants

    International Nuclear Information System (INIS)

    Schumann, F.; Merbach, W.; Freye, E.; Schilling, G.

    1988-01-01

    Apparent CO 2 assimilation and 14 C incorporation into intact plants (Hordeum distichon L., Beta vulgaris L., and Vicia faba L.) were simultaneously measured on the same leaf, using a simple combination of the URAS technique (infrared absorption recorder) and 14 CO 2 fumigation in an open system. As a result of 14 C discrimination during the CO 2 incorporation and respiration losses during harvest and post-harvest treatment, the 14 C method gave always lower CO 2 assimilation values (by 17 to 25%) than the URAS technique. Nevertheless, the results obtained by both methods were closely correlated. Therefore, for quantifying the assimilated CO 2 properly and simultaneously tracing the assimilates synthesized from CO 2 , it is not sufficient to measure solely 14 C incorporation, but to combine both techniques. The system presented is qualified to meet these requirements. (author)

  10. Projected range contractions of European protected oceanic montane plant communities: focus on climate change impacts is essential for their future conservation.

    Science.gov (United States)

    Hodd, Rory L; Bourke, David; Skeffington, Micheline Sheehy

    2014-01-01

    Global climate is rapidly changing and while many studies have investigated the potential impacts of this on the distribution of montane plant species and communities, few have focused on those with oceanic montane affinities. In Europe, highly sensitive bryophyte species reach their optimum occurrence, highest diversity and abundance in the north-west hyperoceanic regions, while a number of montane vascular plant species occur here at the edge of their range. This study evaluates the potential impact of climate change on the distribution of these species and assesses the implications for EU Habitats Directive-protected oceanic montane plant communities. We applied an ensemble of species distribution modelling techniques, using atlas data of 30 vascular plant and bryophyte species, to calculate range changes under projected future climate change. The future effectiveness of the protected area network to conserve these species was evaluated using gap analysis. We found that the majority of these montane species are projected to lose suitable climate space, primarily at lower altitudes, or that areas of suitable climate will principally shift northwards. In particular, rare oceanic montane bryophytes have poor dispersal capacity and are likely to be especially vulnerable to contractions in their current climate space. Significantly different projected range change responses were found between 1) oceanic montane bryophytes and vascular plants; 2) species belonging to different montane plant communities; 3) species categorised according to different biomes and eastern limit classifications. The inclusion of topographical variables in addition to climate, significantly improved the statistical and spatial performance of models. The current protected area network is projected to become less effective, especially for specialised arctic-montane species, posing a challenge to conserving oceanic montane plant communities. Conservation management plans need significantly

  11. Projected range contractions of European protected oceanic montane plant communities: focus on climate change impacts is essential for their future conservation.

    Directory of Open Access Journals (Sweden)

    Rory L Hodd

    Full Text Available Global climate is rapidly changing and while many studies have investigated the potential impacts of this on the distribution of montane plant species and communities, few have focused on those with oceanic montane affinities. In Europe, highly sensitive bryophyte species reach their optimum occurrence, highest diversity and abundance in the north-west hyperoceanic regions, while a number of montane vascular plant species occur here at the edge of their range. This study evaluates the potential impact of climate change on the distribution of these species and assesses the implications for EU Habitats Directive-protected oceanic montane plant communities. We applied an ensemble of species distribution modelling techniques, using atlas data of 30 vascular plant and bryophyte species, to calculate range changes under projected future climate change. The future effectiveness of the protected area network to conserve these species was evaluated using gap analysis. We found that the majority of these montane species are projected to lose suitable climate space, primarily at lower altitudes, or that areas of suitable climate will principally shift northwards. In particular, rare oceanic montane bryophytes have poor dispersal capacity and are likely to be especially vulnerable to contractions in their current climate space. Significantly different projected range change responses were found between 1 oceanic montane bryophytes and vascular plants; 2 species belonging to different montane plant communities; 3 species categorised according to different biomes and eastern limit classifications. The inclusion of topographical variables in addition to climate, significantly improved the statistical and spatial performance of models. The current protected area network is projected to become less effective, especially for specialised arctic-montane species, posing a challenge to conserving oceanic montane plant communities. Conservation management plans need

  12. An expert system design incorporating fuzzy logic for diagnosing heat imbalances in a nuclear power plant

    International Nuclear Information System (INIS)

    Guth, M.A.S.

    1987-01-01

    This paper presents an expert system for diagnosing problems in the interface between the heat exchanger and the core of a nuclear power plant for a hypothetical pressurized water reactor (PWR). The expert system has a production rule backward-chaining-based architecture, and the knowledge base incorporates four kinds of information. First, the structural relationship between causes and consequences is given by nuclear engineering experts. Second, numerical values for the initiating events can be taken from observed performance of the reactor under normal conditions. Third, the causes of particular events are ranked in order of their likelihood based on a combination of a priori knowledge about the reactor design and actual data on the incidence of component failures. Fourth, Bellman-Zadeh Fuzzy Logic is introduced to maintain truth values for expert system rules that hold with varying degrees of certainty

  13. Incorporation of carbohydrate residues into peroxidase isoenzymes in horseradish roots.

    Science.gov (United States)

    Lew, J Y; Shannon, L M

    1973-11-01

    Sliced root tissue of the horseradish plant (Armoracia rusticana), when incubated with mannose-U-(14)C, incorporated radioactivity into peroxidase isoenzymes. Over 90% of the radioactivity in the highly purified peroxidase isoenzymes was present in the neutral sugar residues of the molecule, i.e. fucose, arabinose, xylose, mannose. When the root slices were incubated simultaneously with leucine-4,5-(3)H and mannose-U-(14)C, cycloheximide strongly inhibited leucine incorporation into the peptide portion of peroxidase isoenzymes but had little effect on the incorporation of (14)C into the neutral sugars. These results indicated that synthesis of the peptide portion of peroxidase was completed before the monosaccharide residues were attached to the molecule. This temporal relationship between the synthesis of protein and the attachment of carbohydrate residues in the plant glycoprotein, horseradish peroxidase, appears to be similar to that reported for glycoprotein biosynthesis in many mammalian systems.

  14. United States Department of Energy's reactor core protection evaluation methodology for fires at RBMK and VVER nuclear power plants. Revision 1

    International Nuclear Information System (INIS)

    1997-06-01

    This document provides operators of Soviet-designed RBMK (graphite moderated light water boiling water reactor) and VVER (pressurized light water reactor) nuclear power plants with a systematic Methodology to qualitatively evaluate plant response to fires and to identify remedies to protect the reactor core from fire-initiated damage

  15. Thermal spraying of corrosion protection layers in biogas plants; Erzeugung von Korrosionsschutzschichten fuer Bioenergieanlagen mittels Thermischen Spritzens

    Energy Technology Data Exchange (ETDEWEB)

    Crimmann, P.; Dimaczek, G.; Faulstich, M. [ATZ Entwicklungszentrum, Sulzbach-Rosenberg (Germany)

    2004-07-01

    Corrosion in plants for the energetic conversion of biomass is a severe problem that often causes premature damage of components. Thermal spraying is a process for the creation of corrosion protection layer. An advantage of thermal spraying is that as well as each material can be used as layer material. First practical results demonstrated that thermal spraying has the potential to create coatings to protect components against high temperature corrosion as well as biocorrosion. Layer materials are for example nickel base alloys (high temperature corrosion) and titan alloys (biocorrosion). Further investigations are necessary in order to examine whether cost-efficient coatings also contribute to the corrosion protection (e.g. polymer materials against biocorrosion). (orig.)

  16. Radiation protection for repairs of reactor's internals at the 2nd Unit of the Nuclear Power Plant Temelin

    International Nuclear Information System (INIS)

    Zapletal, P.; Konop, R.; Koc, J.; Kvasnicka, O.; Hort, M.

    2011-01-01

    This presentation describes the process and extent of repairs of the 2 nd unit of the Nuclear power plant Temelin during the shutdown of the reactor. All works were optimized in terms of radiation protection of workers.

  17. New approach to the problem of increasing the environmental protection during a severe accident at a nuclear power plant

    International Nuclear Information System (INIS)

    Kulyukhin, S.A.; Mikheev, N.B.; Kamenskaya, A.N.; Rumer, I.A.; Kazakevich, M.Z.; Novichenko, V.L.

    1996-01-01

    Although the probability of severe accidents is very low (less than 10 -5 ), these accidents have very hazardous consequences and can lead to an extensive contamination of the territory with radioactive compounds (e.g., Chernobyl accident in 1986). To minimize the consequences of such accidents at nuclear power plants (NPP), much attention is being given to operational safety issues. Particular emphasis has been placed on the in-depth protection, i.e., a multilevel protection. In order to increase the efficiency of available systems of environmental protection in both operating and projected NPPs, we have developed a new concept based on the use of man-made hydrophilic aerosols that can form mixed aerosol particles with radio-aerosols. The fundamental investigations performed have shown that the resulting mixed aerosols incorporate radio-aerosols with particle size less that 0.1 μm. These radio-aerosols acquire the properties of the macro-aerosols; i.e., hydrophobic aerosols become hydrophilic. The use of hydrophilic macro-aerosols allows the scrubber efficiency to be increased with respect to hydrophobic cesium aerosols (with particle size less than 0.1μ) by a factor of more than 50. Simultaneously, for operating NPPs supplied with under-containment pressure-relief system, we suggest a decontamination setup of a new type. This setup can work both of the decontamination of the vapor-air flow cesium and iodine radio-aerosols is 10 5 - 10 7 . As to the NPP projects now under development, the use of man-made aerosols under the containment at the time of an accident will allow the sedimentation rate of radio-aerosols to be significantly increased, and this will ensure a rapid removal of radioactivity from under the containment. Our investigations have shown that ammonium chloride increases the sedimentation rate of nano-metric cesium radio-aerosol particles by a factor of more than 100. Thus, an almost complete trapping of radio-aerosols through the use of man

  18. Incorporation of tritium due to foliar exposure in certain vegetation

    International Nuclear Information System (INIS)

    Iyengar, T.S.; Sadarangani, S.H.; Vaze, P.K.; Soman, S.D.

    1981-01-01

    Tritium uptake, release and incorporation patterns through the foliage of seedlings of certain edible vegetation were investigated, for exposure periods ranging from an hour to about 20 hours. A large number of plants belonging to the family of lettuce (Lactuca sativa L.), cabbage (Brassica Oleracea L.) and capsicum (Capsicum fruitescens L.) were exposed to tritiated air under dynamic and static conditions. The half times for tissue-free-water-tritium (TFWT) were found to be about 46 and 32 minutes for capsicum and lettuce and 45 minutes for cabbage. Tissue-bound-tritium (TBT) in the seedlings and the grown plants showed different incorporation rates as a result of foliar exposure. The relative concentration factors were larger by a factor of ten for TFWT in the leaves of the grown plants than in the shoots of the seedlings. However, tissue-bound-tritium concentration values in the shoots/stems of the young and grown plants were of the same order, as related to the tissue-free-water-tritium concentrations. Thus the study indicates a larger translocation of tritium from aqueous to organic phase in the leaves of the grown plants than in the shoots of young seedlings. (auth.)

  19. Protective effects of plant seed extracts against amyloid β-induced neurotoxicity in cultured hippocampal neurons

    Directory of Open Access Journals (Sweden)

    Yoshinori Okada

    2013-01-01

    Full Text Available Aim: Alzheimer′s disease (AD is characterized by large deposits of amyloid β (Aβ peptide. Aβ is known to increase reactive oxygen species (ROS production in neurons, leading to cell death. In this study, we screened 15 plant seeds′ aqueous extracts (PSAE for inhibitory effects on Aβ (25-35-induced cell death using hippocampus neurons (HIPN. Materials and Methods: Fifteen chosen plants were nine medical herbs (Japanese honeywort, luffa, rapeseed, Chinese colza, potherb mustard, Japanese radish, bitter melon, red shiso, corn, and kaiware radish and six general commercial plants (common bean, komatsuna, Qing geng cai, bell pepper, kale, and lettuce. PSAE were measured for total phenolic content (TPC with the Folin-Ciocalteu method, and the 2-diphenyl-1-picryl-hydrazyl (DPPH radical scavenging effect of each seed extract was measured. To find a protectant against Aβ-induced oxidative stress, we screened 15 PSAE using a 2′, 7′-dichlorofluorescein diacetate assay. To further unravel the anti-inflammatory effects of PSAE on Aβ-induced inflammation, PSAE were added to HIPN. The neuroprotective effects of the PSAE were evaluated by Cell Counting Kit-8 assay, measuring the cell viability in Aβ-induced HIPN. Results: TPC of 15 PSAE was in the range of 0.024-1.96 mg of chlorogenic acid equivalents/gram. The aqueous extracts showed antioxidant activities. Furthermore, intracellular ROS accumulation resulting from Aβ treatment was reduced when cells were treated with some PSAE. Kale, bitter melon, kaiware radish, red shiso, and corn inhibited tumor necrosis factor-alpha secretion by the Aβ-stimulated neurons and all samples except Japanese honeywort showed enhancement of cell survival. Conclusion: From these results, we suggest that some plant seed extracts offer protection against Aβ-mediated cell death.

  20. CHALLENGES AND OPPORTUNITIES--INTEGRATED LIFE-CYCLE OPTIMIZATION INITIATIVES FOR THE HANFORD RIVER PROTECTION PROJECT--WASTE TREATMENT PLANT

    International Nuclear Information System (INIS)

    Auclair, K. D.

    2002-01-01

    This paper describes the ongoing integrated life-cycle optimization efforts to achieve both design flexibility and design stability for activities associated with the Waste Treatment Plant at Hanford. Design flexibility is required to support the Department of Energy Office of River Protection Balance of Mission objectives, and design stability to meet the Waste Treatment Plant construction and commissioning requirements in order to produce first glass in 2007. The Waste Treatment Plant is a large complex project that is driven by both technology and contractual requirements. It is also part of a larger overall mission, as a component of the River Protection Project, which is driven by programmatic requirements and regulatory, legal, and fiscal constraints. These issues are further complicated by the fact that both of the major contractors involved have a different contract type with DOE, and neither has a contract with the other. This combination of technical and programmatic drivers, constraints, and requirements will continue to provide challenges and opportunities for improvement and optimization. The Bechtel National, Inc. team is under contract to engineer, procure, construct, commission and test the Waste Treatment Plant on or ahead of schedule, at or under cost, and with a throughput capacity equal to or better than specified. The Department of Energy is tasked with the long term mission of waste retrieval, treatment, and disposal. While each mission is a compliment and inextricably linked to one another, they are also at opposite ends of the spectrum, in terms of expectations of one another. These mission requirements, that are seemingly in opposition to one another, pose the single largest challenge and opportunity for optimization: one of balance. While it is recognized that design maturation and optimization are the normal responsibility of any engineering firm responsible for any given project, the aspects of integrating requirements and the management

  1. Protected air-cooled condenser for the Clinch River Breeder Reactor Plant

    International Nuclear Information System (INIS)

    Louison, R.; Boardman, C.E.

    1981-01-01

    The long term residual heat removal for the Clinch River Breeder Reactor Plant (CRBRP) is accomplished through the use of three protected air-cooled condensers (PACC's) each rated at 15M/sub t/ following a normal or emergency shutdown of the reactor. Steam is condensed by forcing air over the finned and coiled condenser tubes located above the steam drums. The steam flow is by natural convection. It is drawn to the PACC tube bundle for the steam drum by the lower pressure region in the tube bundle created from the condensing action. The concept of the tube bundle employs a unique patented configuration which has been commercially available through CONSECO Inc. of Medfore, Wisconsin. The concept provides semi-parallel flow that minimizes subcooling and reduces steam/condensate flow instabilities that have been observed on other similar heat transfer equipment such as moisture separator reheaters (MSRS). The improved flow stability will reduce temperature cycling and associated mechanical fatigue. The PACC is being designed to operate during and following the design basis earthquake, depressurization from the design basis tornado and is housed in protective building enclosure which is also designed to withstand the above mentioned events

  2. Equivalent Modeling of DFIG-Based Wind Power Plant Considering Crowbar Protection

    Directory of Open Access Journals (Sweden)

    Qianlong Zhu

    2016-01-01

    Full Text Available Crowbar conduction has an impact on the transient characteristics of a doubly fed induction generator (DFIG in the short-circuit fault condition. But crowbar protection is seldom considered in the aggregation method for equivalent modeling of DFIG-based wind power plants (WPPs. In this paper, the relationship between the growth of postfault rotor current and the amplitude of the terminal voltage dip is studied by analyzing the rotor current characteristics of a DFIG during the fault process. Then, a terminal voltage dip criterion which can identify crowbar conduction is proposed. Considering the different grid connection structures for single DFIG and WPP, the criterion is revised and the crowbar conduction is judged depending on the revised criterion. Furthermore, an aggregation model of the WPP is established based on the division principle of crowbar conduction. Finally, the proposed equivalent WPP is simulated on a DIgSILENT PowerFactory platform and the results are compared with those of the traditional equivalent WPPs and the detailed WPP. The simulation results show the effectiveness of the method for equivalent modeling of DFIG-based WPP when crowbar protection is also taken into account.

  3. The use of plants to protect plants and food against fungal pathogens

    African Journals Online (AJOL)

    Background: Plant fungal pathogens play a crucial role in the profitability, quality and quantity of plant production. These phytopathogens are persistent in avoiding plant defences causing diseases and quality losses around the world that amount to billions of US dollars annually. To control the scourge of plant fungal ...

  4. 75 FR 70235 - Access to Confidential Business Information by Industrial Economics, Incorporated

    Science.gov (United States)

    2010-11-17

    ... Industrial Economics, Incorporated AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Access to Data and Request for Comments. SUMMARY: EPA will authorize its contractor, Industrial Economics... Contracts Nos. GS-10F-0061N (EP10H000898) and EP-W-06- 065/0013, Industrial Economics, Incorporated (IEc...

  5. 75 FR 1053 - Access to Confidential Business Information by Industrial Economics, Incorporated

    Science.gov (United States)

    2010-01-08

    ... Industrial Economics, Incorporated AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Access to Data and Request for Comments. SUMMARY: EPA will authorize its contractor, Industrial Economics... Contracts No. EP-W-6-065 and EP07H000213, Industrial Economics, Incorporated (IEc) will assist the Office of...

  6. Tobacco expressing pap1 increases the responses to par and uv-a by enhancing soluble sugars and flavonoids and elevating plant protections

    International Nuclear Information System (INIS)

    Sompornpailin, K.; Kanthang, S.

    2015-01-01

    Five lines of transgenic tobacco over-expressing Production of Anthocyanin Pigment 1 (PAP1) cDNA were analysis of metabolic response against the radiation and their protection of the plant under tissue culture condition. PAP1 transgenic and wild type (WT) plants were treated with the radiations of photosynthetically activate radiation (PAR) or PAR combined with UV-A. All lines of transgenic significantly increased in amounts of p-coumaric acid, naringenin apigenin more than WT under both treatments. Additional UV-A radiating to plant rose up kaempferol content in WT plant (1.5 times) and in PAP1 transgenics (1.8 times). These transgenic plants treated under both conditions had also increased anthocyanin substances (pelargonidin) with significant value after compared to WT. Content of total soluble sugar (TSS) was related to the content of total flavonoids in transgenic. PAR combined with UV-A had a lower induction of the electrolyte leakage percentage and malondialdehyde (MDA) level in the transgenic leaf tissue compared to WT tissue. The metabolic substance levels were considered on its protection of plant cells. In transgenic tissue, the enhancement of apigenin level strongly diminished the increase level of electrolyte leakage while the levels of TSS, p-coumaric acid and naringinin less affected. Moreover, the increase levels of kaempferol and pelargonidin associated with the decrease level of MDA, while the TSS level reversely responded. The PAP1 transgenic increased response of light by adaptation of their metabolites (TSS, p-coumaric acid and flavonoids) consequently enhance parameter indicating protections of the cell. (author)

  7. Regulation of non-relevant metabolites of plant protection products in drinking and groundwater in the EU: Current status and way forward.

    Science.gov (United States)

    Laabs, V; Leake, C; Botham, P; Melching-Kollmuß, S

    2015-10-01

    Non-relevant metabolites are defined in the EU regulation for plant protection product authorization and a detailed definition of non-relevant metabolites is given in an EU Commission DG Sanco (now DG SANTE - Health and Food Safety) guidance document. However, in water legislation at EU and member state level non-relevant metabolites of pesticides are either not specifically regulated or diverse threshold values are applied. Based on their inherent properties, non-relevant metabolites should be regulated based on substance-specific and toxicity-based limit values in drinking and groundwater like other anthropogenic chemicals. Yet, if a general limit value for non-relevant metabolites in drinking and groundwater is favored, an application of a Threshold of Toxicological Concern (TTC) concept for Cramer class III compounds leads to a threshold value of 4.5 μg L(-1). This general value is exemplarily shown to be protective for non-relevant metabolites, based on individual drinking water limit values derived for a set of 56 non-relevant metabolites. A consistent definition of non-relevant metabolites of plant protection products, as well as their uniform regulation in drinking and groundwater in the EU, is important to achieve legal clarity for all stakeholders and to establish planning security for development of plant protection products for the European market. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Thematic strategy on sustainable use of plant protection products. Prospects and requirements for transferring proposals for plant protection products to biocides

    Energy Technology Data Exchange (ETDEWEB)

    Gartiser, Stefan [Hydrotox GmbH, Freiburg im Breisgau (Germany); Lueskow, Heike [Institut fuer Oekologie und Politik GmbH (OEKOPOL), Hamburg (Germany); Gross, Rita [Oeko-Institut e.V. - Institut fuer Angewandte Oekologie e.V., Freiburg im Breisgau (Germany)

    2012-03-15

    The sustainable use of pesticides pursues, independent of the authorisation of single products, the aim to minimise existing environmental risks of pesticide use and therefore contribute to the reduction of its impact on the environmental protection goals. The Thematic Strategy (TS) and the Framework Directive 2009/128/EC (FWD) on sustainable use of pesticides have so far only been implemented for plant protection products (PPP). For biocides there exists no harmonised approach. Within the project the possibilities and requirements for transferring measures of the FWD to the biocide area have been analysed, with specific focus on wood preservatives, insecticides, and antifouling products. Several biocidal active substances are found in the outlets of sewage treatment plants and in surface water, but an inventory of the present environmental impact as well as reliable data on biocide consumption and use patterns, which could be used to identify key action areas, are generally missing. These data are urgently needed for the development of suitable indicators and the definition of the objectives. Sustainable use of biocides addresses the three issues; social, environmental and economic impact at which the ecological background assigns the borderline and beam barrier of the economic and social development. A systematic analysis of the instruments for improving sustainable use of pesticides described in TS and FWD indicated that many issues can be transferred to the biocide area. This concerns e.g. education and training, requirements for sales, the establishment of awareness programmes, control of the machinery for biocide application, the development of best practice standards based on integrated pest management principles, and the collection of statistics on biocide consumption. Some biocide specific characteristics need to be considered: E.g. unlike PPP, the intended use of some biocides is to be directly applied in water bodies or indoors. Furthermore for some

  9. The occurence of rare and protected plant species on the peat bog near Lake Bikcze (Łęczyńsko-Włodawskie Lakeland

    Directory of Open Access Journals (Sweden)

    Magdalena Pogorzelec

    2012-12-01

    Full Text Available This paper presents the results of a pilot field study, conducted in July 2007, designed to make floristic evaluation of the peat bog area adjacent to the western shore of Lake Bikcze (Łęczyńsko-Włodawskie Lakeland. The main aim of the study was to confirm the occurrence of populations of rare and legally protected plant species in this area and to identify, on a preliminary basis, habitat conditions in their stands. The occurrence of populations of the following strictly protected plant species: Betula humilis, Salix lapponum, Salix myrtilloides, Carex limosa, Drosera intermedia, Drosera rotundifolia, Dactylorhiza incarnata; and partially protected species: Menyanthes trifoliata, has been confirmed in the studied peat bog. Both an investigation of abiotic factors, conducted in situ, and an analysis of the species composition of the flora in terms of habitat preferences of particular groups of taxa have shown that the described rare plant species find suitable conditions for their growth and development in the studied peat bog.

  10. Role of marine macroalgae in plant protection & improvement for sustainable agriculture technology

    Directory of Open Access Journals (Sweden)

    Seham M. Hamed

    2018-03-01

    Full Text Available Marine macroalgae are plant-like organisms with simple internal structures that generally live in coastal areas. They mainly include different communities of red, brown and green macroalgae. Marine macroalgae commonly occupy intertidal and sublittoral-to-littoral zones on rocks and other hard substrata. They are considered to be an excellent natural biosource in different aspects of agricultural fields. They have great proficiency in improving soil physical and chemical properties. Marine macroalgae are also characterized by producing a large array of biologically active biocidal substances against plant-infecting pathogens. Unfortunately, most available literatures on marine macroalgae and their derivatives mainly focused on their pharmaceutical applications but their potential utilization in sustainable agriculture development is still often regarded as a secondary goal. However, a relatively considerable dataset on marine macroalgae showed that they could play a major role in plant protection and improvement. This review summarizes different aspects of potential macroalgal applications in agriculture. Commercial production and exploitation of specific compounds with interesting biotechnological importance from marine macroalgae including microbicides, nematicides, insecticides, biofertilizers, biostimulators and soil conditioners are highlighted and discussed in detail. Bioactive compounds like fatty acids (in particular polyunsaturated fatty acids (PUFAs, proteins (amino acids, bioflavonoids, sulfated polysaccharides, carotenoids, polyphenols and carbohydrates are considered to have bactericidal, antiviral and fungicidal effects against some plant-infecting pathogens. These biocontrol agents provide multiple benefits and act as useful pointers for improving cultivation practices in diverse habitats. Marine macroalgae can be generally considered as promising multifunctional bioinoculants and ecofriendly environmental tools in recent trends

  11. Basic safety principles of KLT-40C reactor plants

    International Nuclear Information System (INIS)

    Beliaev, V.; Polunichev, V.

    2000-01-01

    The KLT-40 NSSS has been developed for a floating power block of a nuclear heat and power station on the basis of ice-breaker-type NSSS (Nuclear Steam Supply System) with application of shipbuilding technologies. Basic reactor plant components are pressurised water reactor, once-through coil-type steam generator, primary coolant pump, emergency protection rod drive mechanisms of compensate group-electromechanical type. Basic RP components are incorporated in a compact steam generating block which is arranged within metal-water shielding tank's caissons. Domestic regulatory documents on safety were used for the NSSS design. IAEA recommendations were also taken into account. Implementation of basic safety principles adopted presently for nuclear power allowed application of the KLT-40C plant for a floating power unit of a nuclear co-generation station. (author)

  12. A comparative study among fossil fuel power plants in PJM and California ISO by DEA environmental assessment

    International Nuclear Information System (INIS)

    Sueyoshi, Toshiyuki; Goto, Mika

    2013-01-01

    This study compares among fossil fuel power plants in PJM and California ISO by their unified (operational and environmental) performance. DEA (Data Envelopment Analysis) is used as a methodology. For comparative analysis, DEA incorporates strategic concepts such as natural and managerial disposability into the computational process. This study explores both how to measure Returns to Scale (RTS) under natural disposability and how to measure Damages to Scale (DTS) under managerial disposability. This empirical study obtains two implications on US energy policy. One of the two policy implications is that California ISO outperforms PJM in terms of the three unified efficiency measures. The result implies that strict regulation on undesirable outputs, as found in California, is important in enhancing the performance of US fossil fuel power plants. Thus, it is necessary for federal and local governments to regulate the fossil fuel power plants under the strict implementation of environmental protection. Under such a policy direction, it is possible for US fossil fuel power plants to attain economic prosperity (by enhancing their operational efficiencies) and to satisfy environmental regulation (by enhancing their environmental efficiencies). The other policy implication is that coal-fired and gas-fired power plants in PJM and California ISO need to reduce their operational sizes or introduce technology innovation on desirable and undesirable outputs and/or new management for environmental protection within their operations. Meanwhile, oil-fired power plants may increase their operational sizes if they can introduce technology innovation and new management on undesirable outputs. - Highlights: • This study compares fossil fuel power plants in PJM and California ISO. • California ISO outperforms PJM in terms of their unified efficiency measures. • Regulation by Clean Air Act is important for environmental protection. • Fossil fuel power plants need technology

  13. [Plant protection products and their residues : Aspects of consumer safety in context of the new EU regulations].

    Science.gov (United States)

    Banasiak, U; Michalski, B; Pfeil, R; Solecki, R

    2010-06-01

    The law regulating plant protection products (PPP) in the European Union (EU) was fundamentally revised through the introduction of Regulation (EC) No. 1107/2009 which is due to enter into force on 14 June 2011. EU-wide harmonized maximum residue levels (MRLs) for the active substances of PPP in foods are laid down in Regulation (EC) No. 396/2005 and apply since entry into force of the regulation on 1 September 2008. The goal of both regulations is to strengthen the level of consumer protection. PPP are subject to a strict assessment of active substances, which is regulated at the EU level as well as an authorization procedure in the EU Member States. Prior to application for authorization of a PPP, the active substance(s) it contains must be included in a positive list. Tests regarding the toxicity and residue behavior of PPP must be conducted by the applicant, and the respective documents must be submitted to the authorities for evaluation. Following review of the required data, toxicological threshold values are derived, consumer exposure is assessed, and the risk to health is evaluated. The goal of this evaluation is to ensure that the use of PPP according to good plant protection practice does not have any harmful effects on human health.

  14. IRSN's Position on Safety and Radiation Protection at Nuclear Power Plants in France in 2013

    International Nuclear Information System (INIS)

    2015-01-01

    This report does not find any notable change in significant safety-related events from the previous report in 2012. Nevertheless, it confirms the increase in the number of significant radiation protection-related events observed since 2010. IRSN notes that the overwhelming majority of events that occurred in 2013 had no significant impact on plant safety and no consequences for the health of workers and the public. The analysis confirms that EDF's efforts appear to be successful in handling the main causes of certain types of events such as periodic tests that had been increasing in recent years. Nevertheless, vigilance over organizational and human aspects is still necessary during a period of significant staff turnover. IRSN has highlighted the considerable progress protecting nuclear plants from internal and external hazards that led or will lead EDF to implement modifications to its reactors. Finally, IRSN continues to pay particular attention to EDF's efforts to improve reactor safety as a result of stress tests performed after the disaster at the Fukushima-Daiichi Nuclear Power Plant in Japan on 11 March 2011. In the report, IRSN also provides its analysis of several events and anomalies that it considered the most significant in 2013

  15. Thermodynamic analysis and economic evaluation of a 1000 MW bituminous coal fired power plant incorporating low-temperature pre-drying (LTPD)

    International Nuclear Information System (INIS)

    Xu, Cheng; Xu, Gang; Zhu, Mingming; Dong, Wei; Zhang, Yang; Yang, Yongping; Zhang, Dongke

    2016-01-01

    Highlights: • An improved design of coal pre-drying using flue gas waste heat was proposed. • 0.4% energy efficiency increase was achieved with the proposed system. • The additional net economic benefit of the proposed system is $1.91 M per year. • Proposed concept can be widely applied to improve coal-fired power plant efficiency. - Abstract: Low-temperature pre-drying (LTPD) of lignite has been identified as an effective approach to improve the efficiency of lignite fired power plants. In this study, an improved concept for the pre-drying of medium moisture bituminous coals using flue gas waste heat was proposed and its feasibility was assessed. In the proposed configuration, the boiler exhaust flue gas is drawn to dryers to heat and pre-dry the raw coal, removing a large proportion of the coal moisture and leading to an improvement in the energy efficiency of the power plant. Thermodynamic analysis and economic evaluation were performed based on a typical 1000 MW bituminous coal fired power plant incorporating the proposed LTPD concept. The results showed that the net power plant efficiency gain is as much as 0.4 percentage point with additional net power output of 9.3 MW as compared to the reference plant without coal pre-drying. This was attributed to the reduction in the moisture content from 10.3 to 2.7 wt%. The additional net economic benefit attained due to the coal pre-drying was estimated to reach $1.91 M per year. This work provides a broadly applicable and economically feasible approach to further improve the energy efficiency of power plants firing coals with medium moisture contents.

  16. Computerized reactor protection and safety related systems in nuclear power plants. Proceedings of a specialists' meeting. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Though the majority of existing control and protection systems in nuclear power plants use old analogue technology and design philosophy, the use of computers in safety and safety related systems is becoming a current practice. The Specialists Meeting on ''Computerized Reactor Protection and Safety Related Systems in Nuclear Power Plants'' was organized by IAEA (jointly by the Division of Nuclear Power and the Fuel Cycle and the Division of Nuclear Installation Safety), in co-operation with Paks Nuclear Power Plant in Hungary and was held from 27-29 October 1997 in Budapest, Hungary. The meeting focused on computerized safety systems under refurbishment, software reliability issues, licensing experiences and experiences in implemented computerized safety and safety related systems. Within a meeting programme a technical visit to Paks NPP was organized. The objective of the meeting was to provide an international forum for the presentation and discussion on R and D, in-plant experiences in I and C important to safety, backfits and arguments for and reservations against the digital safety systems. The meeting was attended by 70 participants from 16 countries representing NPPs and utility organizations, design/engineering, research and development, and regulatory organizations. In the course of 4 sessions 25 technical presentations were made. The present volume contains the papers presented by national delegates and the conclusions drawn from the final general discussion

  17. Radiation protection measures in case of 125I incorporation

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    Thyroid measurements were performed on members of the scientific staff in the whole body counter of the Giessen Radiation Center with an aluminium encapsulated 3'' x 3'' dia. NaI(T1) detector; the personnel under investigation comprised those persons who either handled major quantities of 125 I or worked in the controlled area. The measuring setup, phantom calibration and the limits of measurement that can be attained are discussed. In a few cases of incorporation the effective halflife was determined. The radiation exposure was calculated by the absorbed fractions concept. A hazard is encountered almost exclusively in the iodization of the test substances. (orig./HP) [de

  18. Safety and environmental aspects of deuterium--tritium fusion power plants: work shop summary

    International Nuclear Information System (INIS)

    1978-05-01

    In September of 1977 a workshop was held on the safety and environmental aspects of fusion power plants to consider potential safety and environmental problems of fusion power plants and to reveal solutions or methods of solving those problems. The objective was to promote incorporation of safety and environmental protection into reactor design, thereby reducing the expense and delay of backfitting safety systems after reactor designs are complete. A dialogue was established between fusion reactor designers and safety and environmental researchers. Four topics, each with several subdivisions, were selected for discussion: radiation exposure, accidents, environmental effects, and plant safety. For each topic, discussion focused on the significance of the problem, and adequacy of current technology to solve the problem, design solutions available and research needed to solve the problem

  19. Creating an agricultural world order: regional plant protection problems and international phytopathology, 1878-1939.

    Science.gov (United States)

    Castonguay, Stéphane

    2010-01-01

    Beginning in 1878 with the International Phylloxera Convention of Berne, international conventions have sought to relieve national agricultural industries from two specific burdens. First, by defining phytosanitary practices to be enforced by national plant protection services, these conventions attempted to prevent the introduction of plant diseases and pests into national territories from which they were previously absent. Second, by standardizing these practices - especially through the design of a unique certificate of inspection - the conventions attempted to eliminate barriers such as quarantines affection international agricultural trade. The succession of phytopathological conventions seemed to epitomize the coalescence of an international community against agricultural pests. What actually coalesced was bio-geopolitics wherein plant pathologists and economic entomologists from North America and the British Empire questioned the so-called internationality of the environmental and economic specificities of continental European agriculture, embodied in "international" conventions. Although an international phenomenon, the dissemination of agricultural pests provided opportunities for cooperation on a strictly regional albeit transnational basis that pitted bio-geopolitical spaces against each other. This article retraces the formation of these spaces by analyzing the deliberations of committees and congresses that gathered to define an international agricultural order based on the means to prevent the spread of plant diseases and pests.

  20. Advanced digital technology - improving nuclear power plant performance through maintainability

    International Nuclear Information System (INIS)

    Ford, J.L.; Senechal, R.R.; Altenhein, G.D.; Harvey, R.P.

    1998-01-01

    In today's energy sector there is ever increasing pressure on utilities to operate power plants at high capacity factors. To ensure nuclear power is competitive into the next century, it is imperative that strategic design improvements be made to enhance the performance of nuclear power plants. There are a number of factors that affect a nuclear power plant's performance; lifetime maintenance is one of the major contributors. The maturing of digital technology has afforded ABB the opportunity to make significant design improvements in the area of maintainability. In keeping with ABB's evolutionary advanced nuclear plant design approach, digital technology has systematically been incorporated into the control and protection systems of the most recent Korean nuclear units in operation and under construction. One example of this was the multi-functional design team approach that was utilized for the development of ABB's Digital Plant Protection System (DPPS). The design team consisted of engineers, maintenance technicians, procurement specialists and manufacturing personnel in order to provide a complete perspective on all facets of the design. The governing design goals of increased reliability and safety, simplicity of design, use of off-the-shelf products and reduced need for periodic surveillance testing were met with the selection of proven ABB-Advant Programmable Logic Controllers (PLCs) as the heart of the DPPS. The application of digital PLC technology allows operation for extended periods without requiring routine maintenance or re-calibration. A well documented commercial dedication program approved by the United States Nuclear Regulatory Commission (US NRC) as part of the System 80+ TM Advanced Light Water Reactor Design Certification Program, allowed the use of off-the shelf products in the design of the safety protection system. In addition, a number of mechanical and electrical improvements were made which support maintainability. The result is a DPPS

  1. IRSN's viewpoint on the safety and radiation protection of French nuclear power plants in 2007

    International Nuclear Information System (INIS)

    2009-01-01

    This report presents the viewpoint of the IRSN on the safety and radiation protection of EDF's nuclear power plants (NPPs) in operation during 2007. It does not aim to be exhaustive but rather to highlight the points the IRSN considers important for safety. Contributing to maintaining a high level of safety and radiation protection in nuclear facilities in service is one of the seven challenges of the objectives contract signed between the French Government and the IRSN. Safety demands constant vigilance on the part of all the players involved. It is never definitively acquired and must remain a priority and continuously progress, with the plant operator remaining the first entity responsible for the safety of its facility. For the IRSN, part of this mission firstly involves carefully examining and taking into consideration national and international experience feedback, and new scientific knowledge resulting from research. The implementation of improvements, whether technical or organizational or relating to human skills, then comes secondly. This report comprises four sections. In the first section, the IRSN presents the main trends that emerged from its overall review of the safety of the in-service nuclear power plants. The second section addresses the events that have marked the year due to their impact on safety. It also presents a synthesis of the radiation protection events. The third section is devoted to anomalies displaying a generic nature for several power plants. The last section covers the significant changes implemented or scheduled. These are generally modifications or plans of action intended to improve safety performance in the operation or design of the facilities. In spite of sometimes significant disparities in the results between power plants, the IRSN draws the following conclusions from its global review of the year 2007. First of all, no event had serious consequences in the fields of either safety or radioprotection. This good result must

  2. Safety and Radiation Protection at Swedish Nuclear Power Plants 2005

    International Nuclear Information System (INIS)

    2006-05-01

    -to-date and documented safety analyses must be prepared and actively be included in both the preventive safety work and in connection with plant modifications. The licensees have implemented design analysis projects for a long period of time and clarified and stringent regulations for safety analyses have entered into force in 2005. As a result, updated safety reports exist for many of the facilities and schedules exist for the supplementary work that remains to be done. SKI's reinforced supervision of Barsebaeck 2 continued until the closure of the reactor on May 31, 2005. In SKI's opinion, BKAB mainly handled the lengthy facility closure in a satisfactory manner. The handling of nuclear waste at the nuclear facilities has mainly functioned well. The same applies to the operation of the Repository for Low and Intermediate-level Operational Waste (SFR-1) and the Central Interim Storage Facility for Spent Nuclear Fuel (CLAB). The overall evaluation of the Swedish Radiation Protection Authority (SSI) is that radiation protection at Swedish nuclear power plants has functioned well in 2005. The total radiation dose to the personnel at Swedish nuclear power plants was 9.2 manSv, which agrees with the average value of the total radiation doses over the last five years (9 manSv). No-one received a radiation dose in excess of the established dose limits and the radiation levels in the facilities are largely unchanged compared with previous years. The radiation doses to the public from the Swedish nuclear power plants continue to be low. SSI considers that continuous work is also needed in the future at the facilities to further reduce radioactive releases by applying the best available technique (BAT) and other measures. The control measurements that SSI is conducting on environmental samples from around the nuclear power facilities as well as on radioactive releases to water show a good agreement with the licensees' own measurements

  3. Safety and Radiation Protection at Swedish Nuclear Power Plants 2005

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-15

    other things. Up-to-date and documented safety analyses must be prepared and actively be included in both the preventive safety work and in connection with plant modifications. The licensees have implemented design analysis projects for a long period of time and clarified and stringent regulations for safety analyses have entered into force in 2005. As a result, updated safety reports exist for many of the facilities and schedules exist for the supplementary work that remains to be done. SKI's reinforced supervision of Barsebaeck 2 continued until the closure of the reactor on May 31, 2005. In SKI's opinion, BKAB mainly handled the lengthy facility closure in a satisfactory manner. The handling of nuclear waste at the nuclear facilities has mainly functioned well. The same applies to the operation of the Repository for Low and Intermediate-level Operational Waste (SFR-1) and the Central Interim Storage Facility for Spent Nuclear Fuel (CLAB). The overall evaluation of the Swedish Radiation Protection Authority (SSI) is that radiation protection at Swedish nuclear power plants has functioned well in 2005. The total radiation dose to the personnel at Swedish nuclear power plants was 9.2 manSv, which agrees with the average value of the total radiation doses over the last five years (9 manSv). No-one received a radiation dose in excess of the established dose limits and the radiation levels in the facilities are largely unchanged compared with previous years. The radiation doses to the public from the Swedish nuclear power plants continue to be low. SSI considers that continuous work is also needed in the future at the facilities to further reduce radioactive releases by applying the best available technique (BAT) and other measures. The control measurements that SSI is conducting on environmental samples from around the nuclear power facilities as well as on radioactive releases to water show a good agreement with the licensees' own measurements.

  4. Sulfur mineralization of different plant materials labelled with 35 S

    International Nuclear Information System (INIS)

    Abreu Junior, Cassio H.

    1993-01-01

    This study was carried out, in green house conditions, with the objective of evaluating the effect of incorporation in soil of different plant materials labelled with 35 S and of incubation periods on the availability of sulfur to the bean test plants and on the dynamic of this element in the soil. The bean test plants dry matter yield ranged from 2.00 to 3.79 g/plant, the S content and absorption ranged from 118.20 to 194.04 mg/100 g and 2.61 to 6.34 mg/plant respectively. The 35 S derived from the incorporated bean plant material contributed with 12 to 256% of total S absorbed by bean test plant; rice plant material contributed with 12 to 22%; soybean plant material contributed 11 to 18%; corn plant material at rate of 7 g with, 11 to 19% and corn at rate of 3.5 g; with 7 to 1%. Plant material incorporation showed 35 S using efficiency by bean test plant of 21.41 to 9.94% by incorporated rice plant material, of 16.12 to 7.79% by rice material, of 13.11 to 6.49% by soybean material, of 10.24 to 6.21% by corn at rate of 3.5 g and of 7.41 to 3.81% by corn at rate of 7 g.Incorporated plant material with C/S relationship near 120, such as bean and rice, promoted desirable and favorable alteration in soil, while materials with C/S higher than 250, such as soybean and corn, led to unsatisfactory and undesirable alteration. The characteristic of incorporated plant materials which more affected its behavior was the C/S relationship, which depended on its physiological stage on collect timing. (author)

  5. Protection of plants from ambient ozone by applications of ethylenediurea (EDU): A meta-analytic review

    International Nuclear Information System (INIS)

    Feng Zhaozhong; Wang Shuguang; Szantoi, Zoltan; Chen Shuai; Wang Xiaoke

    2010-01-01

    A meta-analysis was conducted to quantitatively assess the effects of ethylenediurea (EDU) on ozone (O 3 ) injury, growth, physiology and productivity of plants grown in ambient air conditions. Results indicated that EDU significantly reduced O 3 -caused visible injury by 76%, and increased photosynthetic rate by 8%, above-ground biomass by 7% and crop yield by 15% in comparison with non-EDU treated plants, suggesting that ozone reduces growth and yield under current ambient conditions. EDU significantly ameliorated the biomass and yield of crops and grasses, but had no significant effect on tree growth with an exception of stem diameter. EDU applied as a soil drench at a concentration of 200-400 mg/L has the highest positive effect on crops grown in the field. Long-term research on full-grown tree species is needed. In conclusion, EDU is a powerful tool for assessing effects of ambient [O 3 ] on vegetation. - EDU effectively protect plants against ambient ozone.

  6. Decreasing water availability across the globe improves the effectiveness of protective ant-plant mutualisms: a meta-analysis.

    Science.gov (United States)

    Leal, Laura C; Peixoto, Paulo E C

    2017-08-01

    Abiotic conditions can increase the costs of services and/or the benefits of rewards provided by mutualistic partners. Consequently, in some situations, the outcome of mutualisms can move from beneficial to detrimental for at least one partner. In the case of protective mutualisms between ant bodyguards and plants bearing extrafloral nectaries (EFNs), plants from arid environments face a trade-off between EFN production and maintenance and water and carbon economy. This trade-off may increase EFN costs and decrease their value as a defensive strategy to plants in such environments. Despite this, the presence of EFNs is an ubiquitous trait in plants from arid environments, suggesting that they provide greater benefits to plants in these environments to compensate for their higher costs. We used a meta-analysis to investigate if such benefits do increase with decreasing water availability and the possible underlying causes (such as ant behaviour or ant diversity). As predicted, ant effect on EFN plants performance increased as mean annual precipitation decreased. We also found that the frequency of dominant ants on EFN plants increased in drier areas. Due to the more aggressive behaviour of dominant ants, we suggest that they represent an important factor shaping the adaptive value of EFNs to plants in arid environments. © 2016 Cambridge Philosophical Society.

  7. Protection, interlocks and diagnostics

    CERN Document Server

    Griffiths, S A; White, C; Theed, J E

    2006-01-01

    When designing any power converter it is essential to assess and incorporate adequate protection. The main objective is to offer a solution which is safe, reliable and repairable and that achieves its specification within budget. The level of protection found within each converter varies widely and will depend on the topology employed, its application and rating. This document is a guide to the types of protection engineers should consider mainly when designing power converters, as protection added during construction or after installation will always be expensive.

  8. Reduced risk insecticides to control scale insects and protect natural enemies in the production and maintenance of urban landscape plants.

    Science.gov (United States)

    Frank, Steven D

    2012-04-01

    Armored scale insects are among the most difficult to manage and economically important arthropod pests in the production and maintenance of urban landscape plants. This is because of morphological traits that protect them from contact insecticides. I compared initial and season-long control of euonymus scale, Unaspis euonymi Comstock (Hemiptera: Diaspidae), by reduced-risk insecticides (insect growth regulators [IGRs], neonicotinoids, spirotetramat) to determine if they controlled scale as well as more toxic insecticides such as the organophosphate, acephate, and pyrethroid, bifenthrin. I also evaluated how these insecticides affected natural enemy abundance on experimental plants and survival when exposed to insecticide residue. All insecticides tested reduced first generation euonymus scale abundance. In 2009, reinfestation by second generation euonymus scale was highest on plants treated with acetamiprid and granular dinotefuran. In 2010, systemic neonicotinoids and spirotetramat prevented cottony cushion scale infestation 133 d after treatment whereas scale readily infested plants treated with bifenthrin and horticultural oil. Encarsia spp. and Cybocephalus spp. abundance was related to scale abundance. These natural enemies were generally less abundant than predicted by scale abundance on granular dinotefuran treated plants and more abundant on granular thiamethoxam treated plants. Bifenthrin residue killed 90-100% of O. insidiosus and E. citrina within 24 h. My results indicate that reduced risk insecticides can provide season-long scale control with less impact on natural enemies than conventional insecticides. This could have economic and environmental benefits by reducing the number of applications necessary to protect nursery and landscape plants from scale.

  9. Radiation protective clothing

    International Nuclear Information System (INIS)

    Ijiri, Yasuo; Fujinuma, Tadashi; Aso, Tsutomu.

    1991-01-01

    The present invention concerns radiation protective clothings suitable for medical protective clothings, aprons, etc. A primary sheet comprises a lead-incorporated organic polymer layer having a less frictional layer on one side and a contamination-resistant layer on the other side. A secondary sheet comprises a lead-incorporated organic polymer layer having a less frictional layer on one side and a comfortable skin-feeling layer on the other side. The less frictional layers of the primary and the secondary layer are laminated so as to be in contact with each other. Then, they are formed so that the comfortable skin-feeling layer of the secondary sheet is on the inner side, in other words, on the side of a wearer, and the contamination-resistant layer of the primary sheet is on the outer side. With such a constitution, although it involves the lead-incorporated organic polymer sheets of a large weight, it is comfortable to wear because of excellent flexibility and causes less feeling of fatigue even during wearing for a long period of time. (I.N.)

  10. 76 FR 58807 - An Assessment of Decision-Making Processes: Evaluation of Where Land Protection Planning Can...

    Science.gov (United States)

    2011-09-22

    ...: Evaluation of Where Land Protection Planning Can Incorporate Climate Change Information-- Release of Final... Protection Planning can Incorporate Climate Change Information, (EPA/600/R-09/142F). The document was... goal of this report is to evaluate where land protection planning can incorporate climate change...

  11. Focus radiation protection

    International Nuclear Information System (INIS)

    Ebermann, Lutz

    2016-01-01

    The publication of the Bundesamt fuer Strahlenschutz on radiation protection covers the following issues: (i) exposure from natural sources: health hazard due to radon, radiation protection in residential homes, radon in Germany, natural raw materials in industrial processes; (ii) clearance of radioactive wastes: clearance in the frame of nuclear power plant dismantling, the situation in Germany and Europe; (iii) emergency management: principles of radiation protection, fictive sequence of accident events; (iiii) other actual radiation protection topics: more limits - more protection? radiation protection in medicine, occupational radiation protection.

  12. The knowledge-based off-site emergency response system for a nuclear power plant

    International Nuclear Information System (INIS)

    Ho, L.W.; Loa, W.W.; Wang, C.L.

    1987-01-01

    A knowledge-based expert system for a nuclear power plant off-site emergency response system is described. The system incorporates the knowledge about the nuclear power plant behaviours, site environment and site geographic factors, etc. The system is developed using Chinshan nuclear power station of Taipower Company, Taiwan, ROC as a representative model. The objectives of developing this system are to provide an automated intelligent system with functions of accident simulation, prediction and with learning capabilities to supplement the actions of the emergency planners and accident managers in order to protect the plant personnel and the surrounding population, and prevent or mitigate property damages resulting from the plant accident. The system is capable of providing local and national authorities with rapid retrieval data from the site characteristics and accident progression. The system can also provide the framework for allocation of available resources and can handle the uncertainties in data and models

  13. Observations on physical protection methods for protecting against unauthorized acts by an insider

    International Nuclear Information System (INIS)

    Ericson, D.M.; Goldman, L.A.; Lobner, R.R.

    1983-01-01

    Two basic approaches have evolved over the past several years for physical protection against sabotage by insiders. One, area-type physical protection, involves the use of access controls at area boundaries. Current practices at nuclear power plants generally fall into this category. The second, component-level physical protection, involves hardware at individual components as well as access controls at the boundary. The area-type physical protection concepts include team, area, and operational zoning. Team zoning requires the formation of multiperson teams that must be used to gain access to vital areas. Area zoning divides the plant into two or more zones, each of which is operated and maintained by separate, dedicated teams. Operational zoning is a closed-loop access control system that permits an initial vital area access, but blocks access to certain other vital areas until the operability of equipment in the first area is verified by test or inspection. Component-level physical protection is also a closed-loop system in which both area and component access are monitored. Each of the above measures can provide effective protection against an insider in certain instances, but each has weaknesses that must be recognized. An approach for protection against the insider is to take the most promising features of each of the above physical protection measures and supplement these capabilities with damage control and design changes as appropriate for a particular plant

  14. In the right place at the right time: habitat representation in protected areas of South American Nothofagus-dominated plants after a dispersal constrained climate change scenario.

    Directory of Open Access Journals (Sweden)

    Diego Alarcón

    Full Text Available In order to assess the effects of climate change in temperate rainforest plants in southern South America in terms of habitat size, representation in protected areas, considering also if the expected impacts are similar for dominant trees and understory plant species, we used niche modeling constrained by species migration on 118 plant species, considering two groups of dominant trees and two groups of understory ferns. Representation in protected areas included Chilean national protected areas, private protected areas, and priority areas planned for future reserves, with two thresholds for minimum representation at the country level: 10% and 17%. With a 10% representation threshold, national protected areas currently represent only 50% of the assessed species. Private reserves are important since they increase up to 66% the species representation level. Besides, 97% of the evaluated species may achieve the minimum representation target only if the proposed priority areas were included. With the climate change scenario representation levels slightly increase to 53%, 69%, and 99%, respectively, to the categories previously mentioned. Thus, the current location of all the representation categories is useful for overcoming climate change by 2050. Climate change impacts on habitat size and representation of dominant trees in protected areas are not applicable to understory plants, highlighting the importance of assessing these effects with a larger number of species. Although climate change will modify the habitat size of plant species in South American temperate rainforests, it will have no significant impact in terms of the number of species adequately represented in Chile, where the implementation of the proposed reserves is vital to accomplish the present and future minimum representation. Our results also show the importance of using migration dispersal constraints to develop more realistic future habitat maps from climate change predictions.

  15. System for the sealing of containers and pipelines, especially in nuclear power plants

    International Nuclear Information System (INIS)

    Gross, R.

    1976-01-01

    In order to seal containers and pipelines especially in nuclear power plants, it is suggested to incorporate hollow bodies of an elastic material in the pipeline connections which can be blown up by pressure-gas and which are placed for sealing on the inner walls of the pipe. During a longer shutdown, system parts can thus be protected from corrosion. Various forms of such cavities are shown in design examples. The sealed sections can be filled with inert gas (nitrogen). (RW/LH) [de

  16. System for the sealing of containers and pipelines, especially in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Gross, R

    1976-01-22

    In order to seal containers and pipelines especially in nuclear power plants, it is suggested to incorporate hollow bodies of an elastic material in the pipeline connections which can be blown up by pressure-gas and which are placed for sealing on the inner walls of the pipe. During a longer shutdown, system parts can thus be protected from corrosion. Various forms of such cavities are shown in design examples. The sealed sections can be filled with inert gas (nitrogen).

  17. Risk assessment of the biological plant protection product Turex 50 WG, with the organism Bacillus thuringiensis ssp. aizawai CG-91. Opinion of the Panel on Plant Protection Products of the Norwegian Scientific Committee for Food Safety

    OpenAIRE

    Källqvist, Torsten; Dirven, Hubert; Gjøen, Tor; Tronsmo, Arne; Yazdankhah, Siamak Pour; Rivedal, Edgar; Borgå, Katrine; Eklo, Ole Martin; Grung, Merete; Lyche, Jan Ludvig; Låg, Marit; Nilsen, Asbjørn Magne; Sverdrup, Line Emilie

    2016-01-01

    Bacillus thuringiensis are anaerobic, gram-positive bacteria that produce parasporal crystalline protein inclusions, δ-endotoxin, which are toxic to certain invertebrates, especially larvae belonging to the insect orders Coleoptera, Diptera and Lepidoptera. Different strains of Bacillus thuringiensis have therefore a long standing history as plant protective insecticides in many countries, but have not been approved for use in Norway. The Norwegian Scientific Committee for Food Safety (Vitens...

  18. 40 CFR 194.5 - Publications incorporated by reference.

    Science.gov (United States)

    2010-07-01

    .... Nuclear Regulatory Commission, NUREG-1297 “Peer Review for High-Level Nuclear Waste Repositories... Characterization of High-Level Nuclear Waste Repositories” (excluding section 2.1 (b) and (c)); IBR approved for... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Publications incorporated by reference...

  19. Small hydropower plants in Switzerland: definition of spatial priorities, taking into account the conflicting interests of power production and protection of the environment

    International Nuclear Information System (INIS)

    Wehse, Heiko; Pazhepurackel, Vinitha

    2012-01-01

    Due to the promotion of small hydropower plants in Switzerland, a lot of new projects have been planned. This leads to conflicts of interests, especially between ecology and power production. Where should new power plants be built, and which rivers should be protected from any further impact ? In this paper a methodology is developed in order to find answers to those questions. It confronts the oppositional interests for the use and protection of rivers in a transparent way. By doing so, it is hoped to rationalize conflicts. The methodology should help the authorities to evaluate new projects, and it is a basis for regional strategies of river use and protection. The method was tested in collaboration with the cantonal authority of Bern to classify all the rivers of the canton (12'000 km) [Conseil-executif du canton de Berne 2009]. For each river section, the different interests were identified. It has been adapted for the canton of Fribourg to classify the river reaches where new plants are planned [Wehse 2010]. In 2011 the swiss confederation has published a recommendation for the cantonal and communal authorities, concerning the elaboration of cantonal strategies for the use and protection of the rivers [Wehse 2011], which is based on the same method. (authors)

  20. Investigation of the flora, life forms and chorotypes of the plants in the Meymand Protected Area, Kohkilouyeh va Boyer Ahmad provice, Iran

    Directory of Open Access Journals (Sweden)

    Ali-Asghar Naghipour Borj

    2014-11-01

    Full Text Available Floristic studies have great importance as it represent the existence and the status of all plant species in an area. This study aimed to investigate the flora of Meymand Protected Area, located in central Zagros and in Kohkilouyeh va Boyer Ahmad provice with an elevation range of 1806 to 2730 meters from sea level. Plant families, genera and species were identified using taxonomic methods and available resources. According to the results, the flora of this area included 279 plant species belonging to 198 genera from 48 families. The richest families were Asteraceae with 50 species (17.9%, Poaceae, Lamiaceae with each 23 species (8.2% and Fabaceae with 22 species (7.8%. The dominance of hemicryptophytes and therophytes (totally, 82% life forms in the flora, were the characteristics of mountainous regions in central part of Iran. The high proportion of hemicryptophytes plants in the flora also indicated the dominance of a cold and montinious climates in the study area. The chorotypes of plants species showed that 57 percent (160 species of the plant species belonged to Irano-Touranian zone but other remaining species (119 speciecs grew in other geobotanical zones too. There were 5 vulnerable, 24 lower risks and 1 data deficient species in this protected area.

  1. Insect repellent activity of medicinal plant oils against Aedes aegypti (Linn.), Anopheles minimus (Theobald) and Culex quinquefasciatus Say based on protection time and biting rate.

    Science.gov (United States)

    Phasomkusolsil, Siriporn; Soonwera, Mayura

    2010-07-01

    This study investigated insect bite protection and length of the protection with 30 repellents which were divided into 3 categories: plant oil, essential oil and essential oil with ethyl alcohol, tested against three mosquito species, Aedes aegypti, Anopheles minimus and Culex quinquefasciatus, under laboratory conditions. The plant oil group was comprised of Phlai (Zingiber cassumunar) and Sweet basil (Ocimum basilicum). Both substances were effective as repellents and feeding deterrents against An. minimus (205 minutes protection time and a biting rate of 0.9%), Cx. quinquefasciatus (165 minutes protection time and 0.9% biting rate) and Ae. aegypti (90 minutes protection time and 0.8% biting rate). Essential oil from citronella grass (Cymbopogon nardus) exhibited protection against biting from all 3 mosquito species: for An. minimus, Cx. quinquefasciatus and Ae. aegypti, the results were 130 minutes and 0.9%, 140 minutes and 0.8%, and 115 minutes and 0.8%, respectively. The period of protection time against Ae. aegypti for all repellent candidates tested was lower than the Thai Industrial Standards Institute (TISI) determined time of greater than 2 hours.

  2. Endophytes: exploitation as a tool in plant protection

    Directory of Open Access Journals (Sweden)

    Devanushi Dutta

    2014-10-01

    Full Text Available Endophytes are symptomless fungal or bacterial microorganisms found in almost all living plant species reported so far. They are the plant-associated microbes that form symbiotic association with their host plants by colonizing the internal tissues, which has made them valuable for agriculture as a tool in improving crop performance. Many fungal endophytes produce secondary metabolites such as auxin, gibberellin etc that helps in growth and development of the host plant. Some of these compounds are antibiotics having antifungal, antibacterial and insecticidal properties, which strongly inhibit the growth of other microorganisms, including plant pathogens. This article reviews the endophyte isolated from different plants, mode of endophytic infection and benefits derived by the host plant as a result of endophytism.

  3. 75 FR 45583 - New York: Incorporation by Reference of State Hazardous Waste Management Program

    Science.gov (United States)

    2010-08-03

    ...: Incorporation by Reference of State Hazardous Waste Management Program AGENCY: Environmental Protection Agency... authorized hazardous waste program which is set forth in the regulations entitled ``Approved State Hazardous Waste Management Programs'', New York's authorized hazardous waste program. EPA will incorporate by...

  4. 77 FR 59879 - Idaho: Incorporation by Reference of Approved State Hazardous Waste Management Program

    Science.gov (United States)

    2012-10-01

    ...: Incorporation by Reference of Approved State Hazardous Waste Management Program AGENCY: Environmental Protection... ``Approved State Hazardous Waste Management Programs,'' Idaho's authorized hazardous waste program. The EPA... Federal Register, the EPA is codifying and incorporating by reference the State's hazardous waste program...

  5. The responsibilities of the in-plant environmental protection officer under civil law and under criminal law

    International Nuclear Information System (INIS)

    Salje, P.

    1993-01-01

    The scope of responsibilities of the in-plant environmental protection officer covers a wide range of tasks: Water protection, waste management, control of emissions for air pollution abatement, emergency preparedness, radiological protection. What are the consequences for the EP officer in case of neglect? This is the topic of the contribution, discussed from the viewpoint of criminal law and private law. The criminal liability of the EP officer results from the EP officer committing an offence either by wilful act or by neglect, it, in the latter case, the officer is in a warranty position. Under private law, the EP officer is subject to third party liability within the framework defined by Paragraph 823 BGB. There is no possibility for him to claim restriction of liability refering to the enhanced risks involved in his job. Hence a sound professional indemnity insurance is recommendable. (orig.) [de

  6. New risk indicator approach for Operators, Workers, Bystanders and Residents for a sustainable use of plant protection products

    NARCIS (Netherlands)

    Sacchettini, G.; Calliera, M.; Marchis, A.; Glass, R.; Ellis, C.B.; Machera, K.; Gerritsen-Ebben, R.; Spanoghe, P.; Capri, E.

    2015-01-01

    In 2009, the European Union adopted the Directive on Sustainable Use of pesticides (SUD, Directive 2009/128/EC) establishing a framework for achieving a sustainable use of Plant Protection Products (PPPs) through reducing the risks and impacts of PPP use on human health and the environment,

  7. Hanford Waste Simulants Created to Support the Research and Development on the River Protection Project - Waste Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Eibling, R.E.

    2001-07-26

    The development of nonradioactive waste simulants to support the River Protection Project - Waste Treatment Plant bench and pilot-scale testing is crucial to the design of the facility. The report documents the simulants development to support the SRTC programs and the strategies used to produce the simulants.

  8. Safety assessment and feeding value for pigs, poultry and ruminant animals of pest protected (Bt plants and herbicide tolerant (glyphosate, glufosinate plants: interpretation of experimental results observed worldwide on GM plants

    Directory of Open Access Journals (Sweden)

    Aimé Aumaitre

    2010-01-01

    Full Text Available New varieties of plants resistant to pests and/or tolerant to specific herbicides such as maize, soybean, cotton, sugarbeets, canola, have been recently developed by using genetic transformation (GT. These plants contain detectable specificactive recombinant DNA (rDNA and their derived protein. Since they have not been selected for a modification oftheir chemical composition, they can be considered as substantially equivalent to their parents or to commercial varietiesfor their content in nutrients and anti-nutritional factors. However, insect protected maize is less contaminated by mycotoxinsthan its parental counterpart conferring a higher degree of safety to animal feeds. The new feeds, grain and derivatives,and whole plants have been intensively tested in vivo up to 216 days for their safety and their nutritional equivalencefor monogastric farm animals (pig, poultry and ruminants (dairy cows, steers, lambs. The present article is basedon the interpretation and the summary of the scientific results published in original reviewed journals either as full papers(33 or as abstracts (33 available through September 2003. For the duration of the experiments adapted to the species,feed intake, weight gain, milk yield and nutritional equivalence expressed as feed conversion and/or digestibility of nutrientshave never been affected by feeding animals diets containing GT plants. In addition, in all the experimental animals,the body and carcass composition, the composition of milk and animal tissues, as well as the sensory properties of meatare not modified by the use of feeds derived from GT plants. Furthermore, the health of animals, their physiological characteristicsand the survival rate are also not affected.The presence of rDNA and derived proteins can be recognized and quantified in feeds in the case of glyphosate resistant soybeanand canola and in the case of insect protected maize. However, rDNA has never been recovered either in milk, or in

  9. Incorporating the soil environment and microbial community into plant competition theory.

    Science.gov (United States)

    Ke, Po-Ju; Miki, Takeshi

    2015-01-01

    Plants affect microbial communities and abiotic properties of nearby soils, which in turn influence plant growth and interspecific interaction, forming a plant-soil feedback (PSF). PSF is a key determinant influencing plant population dynamics, community structure, and ecosystem functions. Despite accumulating evidence for the importance of PSF and development of specific PSF models, different models are not yet fully integrated. Here, we review the theoretical progress in understanding PSF. When first proposed, PSF was integrated with various mathematical frameworks to discuss its influence on plant competition. Recent theoretical models have advanced PSF research at different levels of ecological organizations by considering multiple species, applying spatially explicit simulations to examine how local-scale predictions apply to larger scales, and assessing the effect of PSF on plant temporal dynamics over the course of succession. We then review two foundational models for microbial- and litter-mediated PSF. We present a theoretical framework to illustrate that although the two models are typically presented separately, their behavior can be understood together by invasibility analysis. We conclude with suggestions for future directions in PSF theoretical studies, which include specifically addressing microbial diversity to integrate litter- and microbial-mediated PSF, and apply PSF to general coexistence theory through a trait-based approach.

  10. Incorporating the soil environment and microbial community into plant competition theory

    Science.gov (United States)

    Ke, Po-Ju; Miki, Takeshi

    2015-01-01

    Plants affect microbial communities and abiotic properties of nearby soils, which in turn influence plant growth and interspecific interaction, forming a plant-soil feedback (PSF). PSF is a key determinant influencing plant population dynamics, community structure, and ecosystem functions. Despite accumulating evidence for the importance of PSF and development of specific PSF models, different models are not yet fully integrated. Here, we review the theoretical progress in understanding PSF. When first proposed, PSF was integrated with various mathematical frameworks to discuss its influence on plant competition. Recent theoretical models have advanced PSF research at different levels of ecological organizations by considering multiple species, applying spatially explicit simulations to examine how local-scale predictions apply to larger scales, and assessing the effect of PSF on plant temporal dynamics over the course of succession. We then review two foundational models for microbial- and litter-mediated PSF. We present a theoretical framework to illustrate that although the two models are typically presented separately, their behavior can be understood together by invasibility analysis. We conclude with suggestions for future directions in PSF theoretical studies, which include specifically addressing microbial diversity to integrate litter- and microbial-mediated PSF, and apply PSF to general coexistence theory through a trait-based approach. PMID:26500621

  11. Incorporating the soil environment and microbial community into plant competition theory

    Directory of Open Access Journals (Sweden)

    Po-Ju eKe

    2015-10-01

    Full Text Available Plants affect microbial communities and abiotic properties of nearby soils, which in turn influence plant growth and interspecific interaction, forming a plant-soil feedback (PSF. PSF is a key determinant influencing plant population dynamics, community structure, and ecosystem functions. Despite accumulating evidence for the importance of PSF and development of specific PSF models, different models are not yet fully integrated. Here, we review the theoretical progress in understanding PSF. When first proposed, PSF was integrated with various mathematical frameworks to discuss its influence on plant competition. Recent theoretical models have advanced PSF research at different levels of ecological organizations by considering multiple species, applying spatially explicit simulations to examine how local-scale predictions apply to larger scales, and assessing the effect of PSF on plant temporal dynamics over the course of succession. We then review two foundational models for microbial- and litter-mediated PSF. We present a theoretical framework to illustrate that although the two models are typically presented separately, their behavior can be understood together by invasibility analysis. We conclude with suggestions for future directions in PSF theoretical studies, which include specifically addressing microbial diversity to integrate litter- and microbial-mediated PSF, and apply PSF to general coexistence theory through a trait-based approach.

  12. Integration of Plant Defense Traits with Biological Control of Arthropod Pests: Challenges and Opportunities.

    Science.gov (United States)

    Peterson, Julie A; Ode, Paul J; Oliveira-Hofman, Camila; Harwood, James D

    2016-01-01

    Crop plants exhibit a wide diversity of defensive traits and strategies to protect themselves from damage by herbivorous pests and disease. These defensive traits may be naturally occurring or artificially selected through crop breeding, including introduction via genetic engineering. While these traits can have obvious and direct impacts on herbivorous pests, many have profound effects on higher trophic levels, including the natural enemies of herbivores. Multi-trophic effects of host plant resistance have the potential to influence, both positively and negatively, biological control. Plant defense traits can influence both the numerical and functional responses of natural enemies; these interactions can be semiochemically, plant toxin-, plant nutrient-, and/or physically mediated. Case studies involving predators, parasitoids, and pathogens of crop pests will be presented and discussed. These diverse groups of natural enemies may respond differently to crop plant traits based on their own unique biology and the ecological niches they fill. Genetically modified crop plants that have been engineered to express transgenic products affecting herbivorous pests are an additional consideration. For the most part, transgenic plant incorporated protectant (PIP) traits are compatible with biological control due to their selective toxicity to targeted pests and relatively low non-target impacts, although transgenic crops may have indirect effects on higher trophic levels and arthropod communities mediated by lower host or prey number and/or quality. Host plant resistance and biological control are two of the key pillars of integrated pest management; their potential interactions, whether they are synergistic, complementary, or disruptive, are key in understanding and achieving sustainable and effective pest management.

  13. Integration of plant defense traits with biological control of arthropod pests: challenges and opportunities

    Directory of Open Access Journals (Sweden)

    Julie A Peterson

    2016-11-01

    Full Text Available Crop plants exhibit a wide diversity of defensive traits and strategies to protect themselves from damage by herbivorous pests and disease. These defensive traits may be naturally occurring or artificially selected through crop breeding, including introduction via genetic engineering. While these traits can have obvious and direct impacts on herbivorous pests, many have profound effects on higher trophic levels, including the natural enemies of herbivores. Multi-trophic effects of host plant resistance have the potential to influence, both positively and negatively, biological control. Plant defense traits can influence both the numerical and functional responses of natural enemies; these interactions can be semiochemically-, plant toxin-, plant nutrient-, and/or physically-mediated. Case studies involving predators, parasitoids, and pathogens of crop pests will be presented and discussed. These diverse groups of natural enemies may respond differently to crop plant traits based on their own unique biology and the ecological niches they fill. Genetically modified crop plants that have been engineered to express transgenic products affecting herbivorous pests are an additional consideration. For the most part, transgenic plant incorporated protectant (PIP traits are compatible with biological control due to their selective toxicity to targeted pests and relatively low non-target impacts, although transgenic crops may have indirect effects on higher trophic levels and arthropod communities mediated by lower host or prey number and/or quality. Host plant resistance and biological control are two of the key pillars of integrated pest management; their potential interactions, whether they are synergistic, complementary, or disruptive, are key in understanding and achieving sustainable and effective pest management.

  14. Acute phytotoxicity of seven metals alone and in mixture: Are Italian soil threshold concentrations suitable for plant protection?

    International Nuclear Information System (INIS)

    Baderna, Diego; Lomazzi, Eleonora; Pogliaghi, Alberto; Ciaccia, Gianluca; Lodi, Marco; Benfenati, Emilio

    2015-01-01

    Metals can pollute soils in both urban and rural areas with severe impacts on the health of humans, plants and animals living there. Information on metal toxicity is therefore important for ecotoxicology. This study investigated the phytotoxicity of different metals frequently found as pollutants in soils: arsenic, cadmium, chromium, lead, mercury, nickel and zinc. Cucumber (Cucumis sativus), sorghum (Sorghum saccharatum) and cress (Lepidium sativum) seeds were used as models for other plants used in human nutrition such as cereals, rice, fruits and vegetables. The 72-h germination rate and root elongations were selected as short-term ecotoxicological endpoints in seeds exposed to single metals and mixtures. Metals were spiked onto OECD standard soils in concentrations comparable to current Italian contamination threshold concentrations for residential and commercial soils. Arsenic, chromium, mercury and nickel were the most toxic metals in our experimental conditions, particularly to cress seeds (5.172, 152 and 255.4 mg/kg as 72 h IC50 for arsenic, mercury and nickel respectively). Italian limits were acceptable for plant protection only for exposure to each metal alone but not for the mixtures containing all the metals concentrations expected by their respective legislative threshold. The effects of the mixture were class-specific: trends were comparable in dicots but different in monocots. The response induced by the mixture at high concentrations differed from that theoretically obtainable by summing the effects of the individual metals. This might be due to partial antagonism of the metals in soil or to the formation of complexes between the metals, which reduce the bioavailability of the pollutants for plants. - Graphical abstract: Metals investigated: Arsenic, Cadmium, Chromium, Lead, Mercury, Nickel and Zinc. - Highlights: • The short-term phytotoxicity of seven metals was investigated with 3 higher plants. • Italian limits for arsenic and nickel in

  15. Acute phytotoxicity of seven metals alone and in mixture: Are Italian soil threshold concentrations suitable for plant protection?

    Energy Technology Data Exchange (ETDEWEB)

    Baderna, Diego, E-mail: diego.baderna@marionegri.it; Lomazzi, Eleonora; Pogliaghi, Alberto; Ciaccia, Gianluca; Lodi, Marco; Benfenati, Emilio

    2015-07-15

    Metals can pollute soils in both urban and rural areas with severe impacts on the health of humans, plants and animals living there. Information on metal toxicity is therefore important for ecotoxicology. This study investigated the phytotoxicity of different metals frequently found as pollutants in soils: arsenic, cadmium, chromium, lead, mercury, nickel and zinc. Cucumber (Cucumis sativus), sorghum (Sorghum saccharatum) and cress (Lepidium sativum) seeds were used as models for other plants used in human nutrition such as cereals, rice, fruits and vegetables. The 72-h germination rate and root elongations were selected as short-term ecotoxicological endpoints in seeds exposed to single metals and mixtures. Metals were spiked onto OECD standard soils in concentrations comparable to current Italian contamination threshold concentrations for residential and commercial soils. Arsenic, chromium, mercury and nickel were the most toxic metals in our experimental conditions, particularly to cress seeds (5.172, 152 and 255.4 mg/kg as 72 h IC50 for arsenic, mercury and nickel respectively). Italian limits were acceptable for plant protection only for exposure to each metal alone but not for the mixtures containing all the metals concentrations expected by their respective legislative threshold. The effects of the mixture were class-specific: trends were comparable in dicots but different in monocots. The response induced by the mixture at high concentrations differed from that theoretically obtainable by summing the effects of the individual metals. This might be due to partial antagonism of the metals in soil or to the formation of complexes between the metals, which reduce the bioavailability of the pollutants for plants. - Graphical abstract: Metals investigated: Arsenic, Cadmium, Chromium, Lead, Mercury, Nickel and Zinc. - Highlights: • The short-term phytotoxicity of seven metals was investigated with 3 higher plants. • Italian limits for arsenic and nickel in

  16. Evaluation of Control and Protection System for Loss of Electrical Power Supply System of Water-Cooling Nuclear Power Plant

    International Nuclear Information System (INIS)

    Suhaemi, Tjipta; Djen Djen; Setyono; Jambiar, Riswan; Rozali, Bang; Setyo P, Dwi; Tjahyono, Hendro

    2000-01-01

    Evaluation of control and protection system for loss of electrical power supply system of water-cooled nuclear power plant has been done. The loss of electrical power supply. The accident covered the loss of external electrical load and loss of ac power to the station auxiliaries. It is analysed by studying and observing the mechanism of electrical power system and mechanism of related control and protection system. The are two condition used in the evaluation i e without turbine trip and with turbine trip. From the evaluation it is concluded that the control and protection system can handled the failure caused by the loss of electrical power system

  17. Flora, life form and chorology of plants of the Helali protected area in Khorasan-e Razavi province

    Directory of Open Access Journals (Sweden)

    Fatemeh Sokhanvar

    2013-11-01

    Full Text Available “Helali protected area” has been officially announced as a no-hunting zone since 1997 and then, became a protected area in 2006. This area with ca. 63495 hectares, is located in the west of Gonabad and southeast of Bajestan, Khorasan-e Razavi province. The area includes mountains, plains and foothills and has a dry and desert climate with warm summers and cold winters based on De Martonne’s aridity index. In investigation of the flora, 318 vascular plant species belonging to 205 genera and 53 families were identified. The most dominant families were Asteraceae, Poaceae, and Brassicaceae with 53, 30, and 26 plant species, respectively. Chorological classification of the flora showed that the majority of the species (56.3% belonged to the Irano-Turanian region. Pluri-regional, cosmopolitan and sub-cosmopolitan elements made up 14.1% of the flora which reflected a disturbance history in the area. Therophytes (47.5% and hemicryptophytes (26.1% were the most important life forms according to Raunkiaer classification.

  18. Safety and Radiation Protection at Swedish Nuclear Power Plants 2004

    International Nuclear Information System (INIS)

    2005-05-01

    Government are part of the reason and will be a feature of the next ten-year period. Furthermore, in new regulations, SKI has introduced more stringent requirements on facility design and construction, based on the experience that has been accumulated since nuclear power was introduced in Sweden. At the same time, the power companies intend to implement power uprating at several of the reactors, which will require extensive safety reviews. Major power uprates require a large amount of analysis work and refurbishment at the facilities in order to take into account increased capacity requirements on safety systems and other factors. During the year, the work on the new regulations for physical protection intensified and a revised draft of regulations and general recommendations has been subjected to a formal review by licensees concerned. During the year, SKI initiated an investigation into how maintenance strategies have developed at Swedish nuclear power plants since the deregulation of the Swedish electricity market in the mid-nineties. The investigation shows that the rate of change over the past five-year period has been faster than during the previous five to ten-year period. Changes have occurred with respect to strategy and organization. Deregulation has been the most important driving force for internal improvements. One conclusion is that the changes have contributed to the learning and development of both individuals and organization. Furthermore, there is no sign of a negative impact on reactor safety. In SKI's opinion, the maintenance activity is extremely important to safety, and supervision will focus on work loads, responsibilities and roles, work satisfaction and motivation, maintenance procedures as well as the possible impact of the combination of financial pressure and a high rate of change. During the year, it was announced that Barsebaeck 2 would be closed down at the end of May 2005. SKI will continue to maintain intensified supervision, which means a

  19. Training in radiation protection of workers at Electricite de France nuclear power plants

    International Nuclear Information System (INIS)

    Aye, Louis

    1980-01-01

    The safety of workers and the population is a major concern of the nuclear industry. In order to carry out its programme of PWR power plants, Electricite de France has largely developed the training in radiation protection of its personnel. Operation workers now represent some 5000 persons; they first receive a formation organized at the national level consisting in training courses, which are completed and continued on the spot. The training makes a wide use of audiovisuals; it is checked by tests and leads to better qualification. Close coordination is sought with outside competent organizations [fr

  20. Regulatory point of view on defense in depth approach to fire protection in nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Rinta-Filppula, Samu; Lehto, Matti; Vaelikangas, Pekka [Radiation and Nuclear Safety Authority STUK, Helsinki (Finland)

    2015-12-15

    The defense-in-depth (DiD) principle is a relatively new approach to fire protection design, even though DiD has been used in nuclear power plant (NPP) safety evaluation and design for decades (IAEA 75-INSAG-3, Rev. 1/INSAG-12). It is the main design criterion in fire protection in the latest edition of Finnish Radiation and Nuclear Safety Authority (STUK) issued guide YVL B.8 for the fire protection in nuclear facilities. The DiD approach to fire protection consists of four levels of defense: preventing the ignition of fires, detecting and extinguishing of ignited fires, preventing fire growth and spreading, confining the fire so that safety functions can be performed irrespective of the effects of the fire. The design of fire protection should take all these levels into account so that fire protection is well balanced and not dependent on a single fire protection factor or level of DiD. Despite being central to the design of fire protection, corresponding evaluations of DiD are done according to more or less unambiguous methods. The main goal of this study is to start the development of such, as much as possible, unambiguous systematic and logical method. First issue then is to build a picture of how fire safety features are executed on different levels of DiD and what is the corresponding safety importance to NPP. The Loviisa NPP was studied as an example case due to a long history of fire safety improvements since commissioning in 1977. The improvements are sorted qualitatively by their means of fire safety impact and level of DiD approach to fire protection and general plant DiD. The correspondence between the two DiD principles is an interesting issue which is discussed in this paper. Finally, Fire PRA is used to determine the safety importance of the improvements. The method proposed for the evaluation of DiD approach to fire protection is a combined ignition root cause analysis - event tree of fire scenario - consequential failure modes and effects analysis