WorldWideScience

Sample records for pit-tag detection studies

  1. Guidelines for calculating and enhancing detection efficiency of PIT tag interrogation systems

    Science.gov (United States)

    Connolly, Patrick J.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  2. Guidelines to indirectly measure and enhance detection efficiency of stationary PIT tag interrogation systems in streams

    Science.gov (United States)

    Connolly, Patrick J.; Wolf, Keith; O'Neal, Jennifer S.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  3. PIT-tagged particle study of bed mobility in a Maine salmon river impacted by logging activities

    Science.gov (United States)

    Thompson, D. M.; Fixler, S. A.; Roberts, K. E.; McKenna, M.; Marshall, A. E.; Koenig, S.

    2017-12-01

    Presenting an interim report on a study on the Narraguagus River in Maine, which utilizes laser total stations cross-sectional surveys and tracking of passive integrated transponder (PIT) tags embedded in glass spheres to document changes in channel-bed characteristics associated with large wood (LW) additions and natural spawning activities. In 2016, work was initiated to monitor changes in bed elevation and sediment mobility with the addition of LW to the Narraguagus River as part of a restoration effort. Ten cross-sections, spaced 5-m apart, were established and surveyed with a laser total station in each of three different study reaches. The study sites include a control reach, a section with anticipated spawning activities and a site with ongoing LW placement. A grid of 200 glass spheres embedded with PIT tags, with twenty alternating 25-mm and 40-mm size particles equally spaced along each of the ten transects, were placed to serve as point sensors to detect sediment mobilization within each reach. In 2017, the site was revisited to determine if differences in PIT-tagged tracer particle mobilization reflect locations were LW was added and places where Atlantic salmon (Salmo salar) and sea lamprey (Petromyzon marinus) construct spawning redds. The positions of PIT-tagged tracer particles was recorded, but particles were not disturbed or uncovered to permit study of potential reworking of buried tracer particles the following year. Full tracer particle recovery will be determined in 2018 to determine if depths of tracer burial and changes in bed elevation vary among places near redds, LW and main channel locations. The data will be used to determine if salmon redds are preferentially located in either places with greater evidence of sediment reworking or alternatively in stable areas? The study will help determine the degree of bed disruption associated with spawning activities and whether LW placement encourages similar sediment mobilization processes.

  4. Raft and floating radio frequency identification (RFID) antenna systems for detecting and estimating abundance of PIT-tagged fish in rivers

    Science.gov (United States)

    Fetherman, Eric R.; Avila, Brian W.; Winkelman, Dana L.

    2016-01-01

    Portable radio frequency identification (RFID) PIT tag antenna systems are increasingly being used in studies examining aquatic animal movement, survival, and habitat use, and their design flexibility permits application in a wide variety of settings. We describe the construction, use, and performance of two portable floating RFID PIT tag antenna systems designed to detect fish that were unavailable for recapture using stationary antennas or electrofishing. A raft antenna system was designed to detect and locate PIT-tagged fish in relatively long (i.e., ≥10 km) river reaches, and consisted of two antennas: (1) a horizontal antenna (4 × 1.2 m) installed on the bottom of the raft and used to detect fish in shallower river reaches (<1 m), and (2) a vertical antenna (2.7 × 1.2 m) for detecting fish in deeper pools (≥1 m). Detection distances of the horizontal antenna were between 0.7 and 1.0 m, and detection probability was 0.32 ± 0.02 (mean ± SE) in a field test using rocks marked with 32-mm PIT tags. Detection probability of PIT-tagged fish in the Cache la Poudre River, Colorado, using the raft antenna system, which covered 21% of the wetted area, was 0.14 ± 0.14. A shore-deployed floating antenna (14.6 × 0.6 m), which covered 100% of the wetted area, was designed for use by two operators for detecting and locating PIT-tagged fish in shorter (i.e., <2 km) river reaches. Detection distances of the shore-deployed floating antenna were between 0.7 and 0.8 m, and detection probabilities during field deployment in the St. Vrain River exceeded 0.52. The shore-deployed floating antenna was also used to estimate abundance of PIT-tagged fish. Results suggest that the shore-deployed floating antenna could be used as an alternative to estimating abundance using traditional sampling methods such as electrofishing.

  5. Raft and floating radio frequency identification (RFID) antenna systems for detecting and estimating abundance of PIT-tagged fish in rivers

    Science.gov (United States)

    Fetherman, Eric R.; Avila, Brian W.; Winkelman, Dana L.

    2016-01-01

    Portable radio frequency identification (RFID) PIT tag antenna systems are increasingly being used in studies examining aquatic animal movement, survival, and habitat use, and their design flexibility permits application in a wide variety of settings. We describe the construction, use, and performance of two portable floating RFID PIT tag antenna systems designed to detect fish that were unavailable for recapture using stationary antennas or electrofishing. A raft antenna system was designed to detect and locate PIT-tagged fish in relatively long (i.e., ≥10 km) river reaches, and consisted of two antennas: (1) a horizontal antenna (4 × 1.2 m) installed on the bottom of the raft and used to detect fish in shallower river reaches (raft antenna system, which covered 21% of the wetted area, was 0.14 ± 0.14. A shore-deployed floating antenna (14.6 × 0.6 m), which covered 100% of the wetted area, was designed for use by two operators for detecting and locating PIT-tagged fish in shorter (i.e., <2 km) river reaches. Detection distances of the shore-deployed floating antenna were between 0.7 and 0.8 m, and detection probabilities during field deployment in the St. Vrain River exceeded 0.52. The shore-deployed floating antenna was also used to estimate abundance of PIT-tagged fish. Results suggest that the shore-deployed floating antenna could be used as an alternative to estimating abundance using traditional sampling methods such as electrofishing.

  6. PIT-tagging method for small fishes: A case study using sandeel ( Ammodytes tobianus )

    DEFF Research Database (Denmark)

    Jørgensen, Michelle Grace Pinto; Deurs, Mikael van; Butts, Ian

    2017-01-01

    Passive integrated transponder (PIT) tags are commonly used to assess fish movement for use in fisheries management. Here, we investigated physiological and behavioral effects of tagging on sandeels (Ammodytes tobianus) using PIT tags constituting 2.1 ± 0.9% of their body weight. Swimming stamina...

  7. PIT Tagging Anurans

    Science.gov (United States)

    McCreary, Brome

    2008-01-01

    The following video demonstrates a procedure to insert a passive integrated transponder (PIT) tag under the skin of an anuran (frog or toad) for research and monitoring purposes. Typically, a 12.5 mm tag (0.5 in.) is used to uniquely identify individual anurans as smal as 40 mm (1.6 in.) in length from snout to vent. Smaller tags are also available and allow smaller anurans to be tagged. The procedure does not differ for other sizes of tages or other sizes of anurans. Anyone using this procedure should ensure that the tag is small enough to fit easily behind the sacral hump of the anuran, as shown in this video.

  8. Sex identification and PIT-tagging: tools and prospects for studying intersexual differences in freshwater fishes

    DEFF Research Database (Denmark)

    Hulthén, K.; Chapman, B.B.; Nilsson, P.A.

    2014-01-01

    the probability of survival within the size range tagged (119–280 m ), nor were there differences in timing of migration the following season between individuals sexed and tagged in spring and individuals tagged in autumn (i.e. outside the reproductive period). Also, a similar per cent of R. rutilus sexed...... and tagged in spring and tagged in autumn migrated the following season (34·5 and 34·7%). Moreover, long-term recapture data revealed no significant differences in body condition between R. rutilus individuals sexed and tagged in spring, individuals tagged in autumn and unmanipulated individuals....... The observed sex ratio of recaptured fish did not differ from the expected values of equal recapture rates between males and females. Hence, there is no observable evidence for an adverse effect of tagging close to the reproductive period and therefore this method is suitable for studying intersexual...

  9. Big Creek Pit Tags

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The BCPITTAGS database is used to store data from an Oncorhynchus mykiss (steelhead/rainbow trout) population dynamics study in Big Creek, a coastal stream along the...

  10. Comparative Performance of Acoustic-tagged and PIT-tagged Juvenile Salmonids

    Energy Technology Data Exchange (ETDEWEB)

    Hockersmith, Eric E.; Brown, Richard S.; Liedtke, Theresa L.

    2008-02-01

    Numerous research tools and technologies are currently being used to evaluate fish passage and survival to determine the impacts of the Federal Columbia River Power System (FCRPS) on endangered and threatened juvenile salmonids, including PIT tags, balloon tags, hydroacoustic evaluations, radio telemetry, and acoustic telemetry. Each has advantages and disadvantages, but options are restricted in some situations because of limited capabilities of a specific technology, lack of detection capability downstream, or availability of adequate numbers of fish. However, there remains concern about the comparative effects of the tag or the tagging procedure on fish performance. The recently developed Juvenile Salmonid Acoustic Telemetry System (JSATS) acoustic transmitter is the smallest active acoustic tag currently available. The goal of this study was to determine whether fish tagged with the JSATS acoustic-telemetry tag can provide unbiased estimates of passage behavior and survival within the performance life of the tag. We conducted both field and laboratory studies to assess tag effects. For the field evaluation we released a total of 996 acoustic-tagged fish in conjunction with 21,026 PIT-tagged fish into the tailrace of Lower Granite Dam on 6 and 13 May. Travel times between release and downstream dams were not significantly different for the majority of the reaches between acoustic-tagged and PIT-tagged fish. In addition to the field evaluation, a series of laboratory experiments were conducted to determine if growth and survival of juvenile Chinook salmon surgically implanted with acoustic transmitters is different than untagged or PIT tagged juvenile Chinook salmon. Only yearling fish with integrated and non-integrated transmitters experienced mortalities, and these were low (<4.5%). Mortality among sub-yearling control and PIT-tag treatments ranged up to 7.7% while integrated and non-integrated treatments had slightly higher rates (up to 8.3% and 7

  11. Cormorant predation on PIT-tagged lake fish

    DEFF Research Database (Denmark)

    Skov, Christian; Jepsen, Niels; Baktoft, Henrik

    2014-01-01

    The present study use data from recovered PIT (Passive Integrated Transponder) tags to explore species-and size-specific annual predation rates by cormorants on three common lacustrine fishes (size range 120-367 mm) in a European lake; roach (Rutilus rutilus), common bream (Abramis brama) and perch...... (Perca fluviatilis). In addition, we quantify the level of age/size truncation that cormorant predation could introduce in a population of perch, an important fish for recreational angling as well as for trophic interactions and ecosystem function in European lakes. Based on three years of PIT tagging...... of fish in Lake Viborg and subsequent recoveries of PIT tags from nearby cormorant roosting and breeding sites, we show that cormorants are major predators of roach, bream and perch within the size groups we investigated and for all species larger individuals had higher predation rates. Perch appear...

  12. Tracing the contribution of debris flow-dominated channels to gravel-bed torrential river channel: implementing pit-tags in the upper Guil River (French Alps)

    Science.gov (United States)

    Arnaud-Fassetta, Gilles; Lissak, Candide; Fort, Monique; Bétard, François; Carlier, Benoit; Cossart, Etienne; Madelin, Malika; Viel, Vincent; Charnay, Bérengère; Bletterie, Xavier

    2014-05-01

    In the upper, wider reaches of Alpine valleys, shaping of active channels is usually subject to rapid change. It mostly depends upon hydro-climatic variability, runoff concentration and sediment supply, and may result in alternating sequences of fluvial and debris-flow pulses, as recorded in alluvial fans and terraces. Our study, carried in the frame of SAMCO (ANR) project, focuses on the upper Guil River Valley (Queyras, Southern French Alps) cut into the slaty shale "schistes lustrés". Steep, lower order drains carry a contrasted solid discharge, including predominantly sandy-loam particles mixed with gravels and boulders (sandstone schists, ophiolites). Abundant sediment supply by frost shattering, snow avalanche and landslides is then reworked during snowmelt or summer storm runoff events, and may result in catastrophic, very destructive floods along the main channel, as shown by historical records. Following the RI-30 year 2000 flood, our investigations included sediment budgets, i.e. balance of erosion and deposition, and the mapping of the source, transport and storage of various sediments (talus, colluvium, torrential fans, terraces). To better assess sediment fluxes and sediment delivery into the main channel network, we implemented tracers (pit-tags) in selected sub-catchments, significantly contributing to the sediment yield of the valley bottoms during the floods and/or avalanches: Maloqueste, Combe Morel, Bouchouse and Peyronnelle catchments. The first three are direct tributaries of the Guil River whereas the Peyronnelle is a left bank tributary of the Peynin River, which joins the Guil River via an alluvial cone with high human and material stakes. The Maloqueste and the Combe Morel are two tributaries facing each other in the Guil valley, representing a double lateral constraint for the road during flood events of the Guil River. After pit-tag initialisation in laboratory, we set them up along the four tributaries: Maloqueste (20 pit-tags), Combe

  13. Novel Use of PIT Tags in Sea Cucumbers: Promising Results with the Commercial Species Cucumaria frondosa.

    Directory of Open Access Journals (Sweden)

    Bruno L Gianasi

    Full Text Available The lack of a reliable and innocuous mark-recapture method has limited studies that would provide essential information for the management of commercial sea cucumbers. Tagging sea cucumbers is notoriously difficult because of their plastic nature and autolysis capacities. The markers that have so far been tested, mainly on or through the body wall, were either lost rapidly or had major drawbacks (e.g. suitable only for batch identification, requiring complex analysis, causing infections, necrosis, behavioural changes and mortality. The present study explored the efficacy of passive integrated transponder (PIT tags for individually marking sea cucumbers by assessing retention rates and long-term side effects of tags inserted in previously unstudied tissues/organs. Individuals of the species Cucumaria frondosa were tagged in the body wall, aquapharyngeal bulb and at the base of the oral tentacles. They were monitored closely for evidence of stress, infection, change in feeding and spawning behaviour and tag retention rate. Implanting the tag in an oral tentacle to reach the hydrovascular system of the aquapharyngeal bulb achieved the best retention rates in full-size individuals: from a maximum of 92% after 30 days to 68% at the end of the experimental period (300 days. Efficacy was lower in smaller individuals (84% after 30 d and 42% after 300 d. Following a slight increase in cloacal movements for 15 h post tagging, no side effect was noted in sea cucumbers tagged in the aquapharyngeal bulb via the tentacles. Feeding and spawning behaviours were not affected and no signs of infections or abnormal cell development in the vicinity of the tags were observed. This study indicates that marking sea cucumbers with 8.2 mm long PIT tags implanted via the oral tentacle is an effective technique, yielding relatively high retention rates over long periods without any detectable physiological or behavioural effects.

  14. PTAGIS - Development of Large PIT-Tag Antennas to Estimate Migration Timing and Survival for Adult Salmonids near Pile Dikes in the Columbia River Estuary

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — We continued research and development of a passive PIT-tag detection system along a pile dike in the estuary (rkm 70). Target fish for this system are returning...

  15. Comparative Survival Study (CSS) of Hatchery PIT-tagged Spring/Summer Chinook; Migration Years 1997-2002 Mark/Recapture Activities and Bootstrap Analysis, 2003-2004 Biennial Report.

    Energy Technology Data Exchange (ETDEWEB)

    Berggren, Thomas J.; Franzoni, Henry; Basham, Larry R. (Columbia Basin Fish and Wildlife Authority, Fish Passage Center, Portland, OR)

    2003-11-01

    The Comparative Survival Study (CSS) was initiated in 1996 as a multi-year program of the fishery agencies and tribes to estimate survival rates over different life stages for spring and summer Chinook (hereafter, Chinook) produced in major hatcheries in the Snake River basin and from selected hatcheries in the lower Columbia River. Much of the information evaluated in the CSS is derived from fish tagged with Passive Integrated Transponder (PIT) tags. A comparison of survival rates of Chinook marked in two different regions (which differ in the number of dams Chinook have to migrate through) provides insight into the effects of the Snake/Columbia hydroelectric system (hydrosystem). The CSS also compares the smolt-to-adult survival rates (SARs) for Snake River Chinook that were transported versus those that migrated in-river to below Bonneville Dam. Additional comparisons can be made within in-river experiences as well as comparison between the different collector projects from which smolts are transported. CSS also compares survival rates for wild Snake River spring and summer Chinook. These comparisons generate information regarding the relative effects of the current management actions used to recover this listed species. Scientists and managers have recently emphasized the importance of delayed hydrosystem mortality to long-term management decisions. Delayed hydrosystem mortality may be related to the smolts experience in the Federal Columbia River Power System, and could occur for both smolts that migrate in-river and smolts that are transported. The CSS PIT tag information on in-river survival rates and smolt-to-adult survival rates (SARs) of transported and in-river fish are relevant to estimation of ''D'', which partially describes delayed hydrosystem mortality. The parameter D is the differential survival rate of transported fish relative to fish that migrate in-river, as measured from below Bonneville Dam to adults returning to Lower

  16. Scanning for PIT-tagged flatfish in a coastal area using a sledge equipped with an RFID antenna

    DEFF Research Database (Denmark)

    Sparrevohn, Claus Reedtz; Aarestrup, Kim; Stenberg, Claus

    2014-01-01

    A radio frequency identification (RFID) antenna system, build into a sledge that can be towed behind a vessel like a trawl and thereby has the potential to detect the position of a passive inductor technology (PIT)-tagged fish in a wide variety of habitats, is presented. By scanning for hatchery...

  17. The application of PIT tags to measure transport of detrital coral fragments on a fringing reef: Majuro Atoll, Marshall Islands

    Science.gov (United States)

    Ford, Murray R.

    2014-06-01

    Passive integrated transponder (PIT) tags are a radio-frequency identification device widely used as a machine-readable identification tool in fisheries research. PIT tags have also been employed, to a lesser extent, to track the movement of gravel-sized clasts within fluvial and coastal systems. In this study, PIT tags were inserted into detrital coral fragments and used to establish source-sink transport pathways on a fringing reef on Majuro Atoll in the Marshall Islands. Results suggest the transport of gravel-sized material on the inter-tidal reef flat is exclusively across-reef towards the lagoon. Considerable variation in the distance travelled by fragments was observed. Fragments were largely intact and visually recognisable after almost 5 months on the reef flat. However, the branches of some recovered fragments had broken off and corallite abrasion was observed in recovered fragments. This study indicates that PIT tags are an inexpensive and powerful new addition to the suite of sediment transport and taphonomic tools for researchers working within coral reef systems.

  18. Methow and Columbia Rivers studies: summary of data collection, comparison of database structure and habitat protocols, and impact of additional PIT tag interrogation systems to survival estimates, 2008-2012

    Science.gov (United States)

    Martens, Kyle D.; Tibbits, Wesley T.; Watson, Grace A.; Newsom, Michael A.; Connolly, Patrick J.

    2014-01-01

    designed to show some initial analysis and to disseminate summary information that could potentially be used in ongoing modeling efforts by USGS, Reclamation, and University of Idaho. The second chapter documents the database of fish and habitat data collected by USGS from 2004 through 2012 and compares USGS habitat protocols to the Columbia Habitat Monitoring Program (CHaMP) protocol. The third chapter is a survival analysis of fish moving through Passive Integrated Transponder (PIT) tag interrogation systems in the Methow and Columbia Rivers. It examines the effects of adding PIT tags and/or PIT tag interrogation systems on survival estimates of juvenile steelhead and Chinook salmon.

  19. Smolt migration characteristics and mainstem Snake and Columbia River detection rates of pit-tagged Grande Ronde and Imnaha River naturally produced spring chinook salmon. 1993, 1994 and 1995 annual reports

    International Nuclear Information System (INIS)

    Walters, T.R.; Carmichael, R.W.; Keefe, M.L.; Sankovich, P.

    1997-01-01

    This reports on the second, third, and fourth years of a multi-year study to assess smolt migration characteristics and cumulative detection rates of naturally produced spring chinook salmon (Oncorhynchus tshawytscha) from Northeast Oregon streams. The goal of this project is to develop an understanding of interpopulational and interannual variation in several early life history parameters of naturally produced spring and summer chinook salmon in the Grande Ronde and Imnaha River subbasins. This project will provide information to assist chinook salmon population recovery efforts. Specific populations included in the study are: (1) Catherine Creek; (2) Upper Grande Ronde River; (3) Lostine River; (4) Imnaha River; (5) Wenaha River; and (6) Minam River. In this document, the authors present findings and activities from research completed in 1993, 1994, and 1995

  20. PIT Tag data - Monitoring the migrations of wild Snake River spring/summer Chinook salmon juveniles

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This is an ongoing Bonneville Power Administration funded project to annually collect, PIT tag, and release wild Chinook salmon parr in up to 17 streams of the...

  1. Design and Analysis of Salmonid Tagging Studies in the Columbia Basin, Volume XIII; Appraisal of System-Wide Survival Estimation of Snake River Yearling Chinook Salmon Released in 1997 and 1988, Using PIT-Tags Recovered from Caspian Tern and Double-Crested Cormorant Breeding Colonies on Rice Island, 1997-1998 Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Skalski, John R.; Perez-Comas, Jose A. (University of Washington, School of Fisheries, Seattle, WA)

    2000-05-01

    PIT-tags recovered from tern and cormorant breeding colonies at Rice Island and observations from the interrogation systems at John Day and Bonneville Dams were incorporated into survival analyses. Whether the estimates for the upper reaches of the system, between Lower Granite and McNary Dams were as expected (with weighted averages S{sub LGR-LGS} = 0.996, S{sub LGS-LMN} = 0.837, and S{sub LMN-McN} = 0.941), those for the lower reaches, between John Day and Bonneville Dams, appeared positively biased with survival estimates typically greater than 1. Their weighted averages were S{sub McN-JDA} = 0.707 and S{sub JDA-BON} = 1.792 for 1997 releases. For the 1998 releases, they were S{sub McN-JDA} = 0.795 and S{sub JDA-BON} = 1.312. If the estimates for the lower reaches were biased, the estimates for the whole project would also be biased (S{sub LGR-BON} = 0.819). We determined that bias could have arisen if the terns and cormorants of Rice Island fished for salmon yearlings in waters of the BON-Rice reach at low rates (M{sub BON-Rice} {le} 0.2), and the rates of tag-deposition and tag-detection were low (R{sub D} x R{sub R} {le} 0.4). Moreover, unknown levels of uncensored post-detection mortality and scavenging of previously dead salmon yearlings may have also added to the bias.

  2. Use of PIT tag and underwater video recording in assessing estuarine fish movement in a high intertidal mangrove and salt marsh creek

    Science.gov (United States)

    Meynecke, Jan-Olaf; Poole, Geoffrey C.; Werry, Jonathan; Lee, Shing Yip

    2008-08-01

    We assessed movement patterns in relation to habitat availability (reflected by the extent of tidal flooding) for several commercially and recreationally important species in and out of a small mangrove creek within the subtropical Burrum River estuary (25°10'S 152°37'E) in Queensland, Australia. Movement patterns of Acanthopagrus australis, Pomadasys kaakan, Lutjanus russelli and Mugil cephalus were examined between December 2006 and April 2007 using a stationary passive integrated transponder (PIT) system adapted for saline environments (30-38 ppt) and underwater digital video cameras (DVCs). This is the second known application of a stationary PIT tag system to studying fish movement in estuarine environments. The transponder system was set in place for 104 days and recorded >5000 detections. Overall 'recapture' rate of tagged fish by the transponder system was >40%. We used PIT tags implanted in a total of 75 fish from a tidal creek connected to the main channel of the estuary. We also developed a high-resolution digital elevation (2.5 m cell size) model of the estuary derived from airborne light detection and ranging (LIDAR) and aerial imagery to estimate inundation dynamics within the tidal creek, and related the timing of inundation in various habitats to the timing of fish immigration to and emigration from the creek. Over 50% of all tagged fish were moving in and out of the creek at a threshold level when 50% of the mangrove forest became flooded. Individuals of all four species moved into and out of the tidal creek repeatedly at different times depending on species and size, indicating strong residential behaviour within the estuary. The main activity of fishes was at night time. Manual interpretation of video from >700 fish sightings at three different mangrove sites confirmed the findings of the stationary PIT system, that the function of shelter vs food in mangrove habitat may be size dependent. Our established techniques assess the spatial ecology

  3. Using RFID and PIT tags to Quantify Bedload Transport in the Oregon Coast Range

    Science.gov (United States)

    Sanfilippo, J.; Lancaster, S. T.

    2017-12-01

    Introducing the methods, issues, and data collection techniques and interpretation over one water year using RFID (radio frequency identification) and PIT (passive integrated transponder) tags in Oak Creek, near Corvallis Oregon. We constructed an RFID four-antenna array that runs off of a single radiofrequency reader via a multiplexer board. Using 4 grain sizes we tagged 990 individual rocks, roughly 250 in of each four size ranges (8-16mm, 16-32mm, 32-64mm, 64-128mm). Using 12 mm and 23 mm PIT tags during 1 water year the antennas logged 477 tracer passage events. To calculate bedload transport for each size range, at each antenna, interarrival times yield count rates when combined with grain size fractions of the bed and tracer concentrations, yield bedload transport for each size class. We calculated transport rates for five events of varying magnitude and found that PIT tag RFID method under predicts transport between 1 and 3 orders of magnitude.

  4. Salmon Supplementation Studies in Idaho Rivers; Field Activities Conducted on Clear and Pete King Creeks, 2001 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Gass, Carrie; Olson, Jim M. (US Fish and Wildlife Service, idaho Fishery Resource Office, Ahsahka, ID)

    2004-11-01

    In 2001 the Idaho Fisheries Resource Office continued as a cooperator on the Salmon Supplementation Studies in Idaho Rivers (ISS) project on Pete King and Clear creeks. Data relating to supplementation treatment releases, juvenile sampling, juvenile PIT tagging, brood stock spawning and rearing, spawning ground surveys, and snorkel surveys were used to evaluate project data points and augment past data. Due to low adult spring Chinook returns to Kooskia National Fish Hatchery (KNFH) in brood year 1999 there was no smolt supplementation treatment release into Clear Creek in 2001. A 17,014 spring Chinook parr supplementation treatment (containing 1000 PIT tags) was released into Pete King Creek on July 24, 2001. On Clear Creek, there were 412 naturally produced spring Chinook parr PIT tagged and released. Using juvenile collection methods, Idaho Fisheries Resource Office staff PIT tagged and released 320 naturally produced spring Chinook pre-smolts on Clear Creek, and 16 natural pre-smolts on Pete King Creek, for minimum survival estimates to Lower Granite Dam. There were no PIT tag detections of brood year 1999 smolts from Clear or Pete King creeks. A total of 2261 adult spring Chinook were collected at KNFH. Forty-three females were used for supplementation brood stock, and 45 supplementation (ventral fin-clip), and 45 natural (unmarked) adults were released upstream of KNFH to spawn naturally. Spatial and temporal distribution of 37 adults released above the KNFH weir was determined through the use of radio telemetry. On Clear Creek, a total of 166 redds (8.2 redds/km) were observed and data was collected from 195 carcasses. Seventeen completed redds (2.1 redds/km) were found, and data was collected data from six carcasses on Pete King Creek.

  5. Efficiency of Portable Antennas for Detecting Passive Integrated Transponder Tags in Stream-Dwelling Salmonids.

    Directory of Open Access Journals (Sweden)

    Nolan P Banish

    Full Text Available Portable antennas have become an increasingly common technique for tracking fish marked with passive integrated transponder (PIT tags. We used logistic regression to evaluate how species, fish length, and physical habitat characteristics influence portable antenna detection efficiency in stream-dwelling brown trout (Salmo trutta, bull trout (Salvelinus confluentus, and redband trout (Oncorhynchus mykiss newberrii marked with 12-mm PIT tags. We redetected 56% (20/36 of brown trout, 34% (68/202 of bull trout, and 33% (20/61 of redband trout after a recovery period of 21 to 46 hours. Models indicate support for length and species and minor support for percent boulder, large woody debris, and percent cobble as parameters important for describing variation in detection efficiency, although 95% confidence intervals for estimates were large. The odds of detecting brown trout (1.5 ± 2.2 [mean ± SE] are approximately four times as high as bull trout (0.4 ± 1.6 or redband trout (0.3 ± 1.8 and species-specific differences may be related to length. Our reported detection efficiency for brown trout falls within the range of other studies, but is the first reported for bull trout and redband trout. Portable antennas may be a relatively unbiased way of redetecting varying sizes of all three salmonid species.

  6. Efficiency of portable antennas for detecting passive integrated transponder tags in stream-dwelling salmonids

    Science.gov (United States)

    Banish, Nolan P.; Burdick, Summer M.; Moyer, Katherine R.

    2016-01-01

    Portable antennas have become an increasingly common technique for tracking fish marked with passive integrated transponder (PIT) tags. We used logistic regression to evaluate how species, fish length, and physical habitat characteristics influence portable antenna detection efficiency in stream-dwelling brown trout (Salmo trutta), bull trout (Salvelinus confluentus), and redband trout (Oncorhynchus mykiss newberrii) marked with 12-mm PIT tags. We redetected 56% (20/36) of brown trout, 34% (68/202) of bull trout, and 33% (20/61) of redband trout after a recovery period of 21 to 46 hours. Models indicate support for length and species and minor support for percent boulder, large woody debris, and percent cobble as parameters important for describing variation in detection efficiency, although 95% confidence intervals for estimates were large. The odds of detecting brown trout (1.5 ± 2.2 [mean ± SE]) are approximately four times as high as bull trout (0.4 ± 1.6) or redband trout (0.3 ± 1.8) and species-specific differences may be related to length. Our reported detection efficiency for brown trout falls within the range of other studies, but is the first reported for bull trout and redband trout. Portable antennas may be a relatively unbiased way of redetecting varying sizes of all three salmonid species.

  7. Fall transport - A study to compare smolt-to-adult return rates (SARs) of Snake River fall Chinook salmon under alternative transport and dam operational strategies

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This U.S. Army Corps of Engineers (USACE)-funded study that began in 2005 compares the SARs of PIT tagged juvenile hatchery Snake River fall Chinook that are split...

  8. Salmon Supplementation Studies in Idaho Rivers; Idaho Supplementation Studies, 2000-2001 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, Chris; Tabor, R.A.; Kinzer, Ryan (Nez Perce Tribe, Department of Fisheries Resource Management, Lapwai, ID)

    2003-04-01

    This report summarizes brood year 1999 juvenile production and emigration data and adult return information for 2000 for streams studied by the Nez Perce Tribe for the cooperative Idaho Salmon Supplementation Studies in Idaho Rivers (ISS) project. In order to provide inclusive juvenile data for brood year 1999, we include data on parr, presmolt, smolt and yearling captures. Therefore, our reporting period includes juvenile data collected from April 2000 through June 2001 for parr, presmolts, and smolts and through June 2002 for brood year 1999 yearling emigrants. Data presented in this report include; fish outplant data for treatment streams, snorkel and screw trap estimates of juvenile fish abundance, juvenile emigration profiles, juvenile survival estimates to Lower Granite Dam (LGJ), redd counts, and carcass data. There were no brood year 1999 treatments in Legendary Bear or Fishing Creek. As in previous years, snorkeling methods provided highly variable population estimates. Alternatively, rotary screw traps operated in Lake Creek and the Secesh River provided more precise estimates of juvenile abundance by life history type. Juvenile fish emigration in Lake Creek and the Secesh River peaked during July and August. Juveniles produced in this watershed emigrated primarily at age zero, and apparently reared in downstream habitats before detection as age one or older fish at the Snake and Columbia River dams. Over the course of the ISS study, PIT tag data suggest that smolts typically exhibit the highest relative survival to Lower Granite Dam (LGJ) compared to presmolts and parr, although we observed the opposite trend for brood year 1999 juvenile emigrants from the Secesh River. SURPH2 survival estimates for brood year 1999 Lake Creek parr, presmolt, and smolt PIT tag groups to (LGJ) were 27%, 39%, and 49% respectively, and 14%, 12%, and 5% for the Secesh River. In 2000, we counted 41 redds in Legendary Bear Creek, 4 in Fishing Creek, 5 in Slate Creek, 153 in the

  9. Evaluation of PIT-tagging in cyprinids

    DEFF Research Database (Denmark)

    Skov, Christian; Brodersen, J.; Brönmark, C.

    2005-01-01

    Laboratory and field experiments were used to investigate how different marking procedures, with 23 mm PIT (passive integrated transponders) - tags. affected mortality, body condition and tag expulsion in small roach Rutilus rutilus and rudd Scardinus erythrophthalmus (117 to 163 mm total length...

  10. Salmon Supplementation Studies in Idaho Rivers; Field Activities Conducted on Clear and Pete King Creeks, 2002 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Bretz, Justin K.; Olson, Jill M. (US Fish and Wildlife Service, Idaho Fishery Resource Office, Ahsahka, ID)

    2003-03-01

    In 2002 the Idaho Fisheries Resource Office continued working as a cooperator on the Salmon Supplementation Studies in Idaho Rivers (ISS) project on Pete King and Clear creeks. Data relating to supplementation treatment releases, juvenile sampling, juvenile PIT tagging, broodstock spawning and rearing, spawning ground surveys, and snorkel surveys were used to evaluate the project data points and augment past data. Supplementation treatments included the release of 51,329 left ventral-clipped smolts into Clear Creek (750 were PIT tagged), and 12,000 unmarked coded-wire tagged parr into Pete King Creek (998 were PIT tagged). Using juvenile collection methods, Idaho Fisheries Resource Office staff PIT tagged and released 579 naturally produced spring chinook juveniles in Clear Creek, and 54 on Pete King Creek, for minimum survival estimates to Lower Granite Dam. For Clear Creek, minimum survival estimates to Lower Granite Dam of hatchery produced supplementation and naturally produced PIT tagged smolts, were 36.0%, and 53.1%, respectively. For Pete King Creek, minimum survival estimates to Lower Granite Dam, of hatchery produced supplementation smolts and naturally produced smolts PIT tagged as parr and presmolts, were 18.8%, and 8.3%, respectively. Adults collected for broodstock in 2002 represented the final adult broodstock group collected for the ISS project. Twenty-six ventral clipped, and 28 natural adult spring chinook were transported above the weir. Monitoring and evaluation of spawning success was continued on Clear and Pete King creeks. A total of 69 redds were counted and 79 carcasses were recovered on Clear Creek. Two redds were observed and no carcasses were collected on Pete King Creek.

  11. Identification of individual foothill yellow-legged frogs (Rana boylii) using chin pattern photographs: a non-invasive and effective method for small population studies

    Science.gov (United States)

    K.R. Marlow; K.D. Wiseman; Clara Wheeler; J.E.  Drennan; R.E.  Jackman

    2016-01-01

    The ability to identify individual animals is a valuable tool in the study of amphibian population dynamics, movement ecology, social behavior, and habitat use. Numerous methods of marking amphibians have been employed including the use of passive integrated transponder (PIT) tags, radio-transmitters, elastomers, branding, and mutilation techniques such as toe...

  12. The design and analysis of salmonid tagging studies in the Columbia Basin. Volume 2: Estimating salmonid survival with combined PIT-CWT tagging. Technical report

    International Nuclear Information System (INIS)

    Newman, K.

    1997-06-01

    Passive Integrated Transponder (PIT) tags and Coded Wire Tags (CWTs) in combination can provide information about salmonid survival that single tag releases may not. The release and recapture protocol affects which survival and recapture rates can be estimated and the precision of the estimates. For the particular case of Columbia river salmonids tagged with both PIT tags and CWTs, three different release and recapture protocols were evaluated. This report addresses the need to study the fate of salmon smolt in-river and their subsequent return as adults. Double-tagging procedures are investigated where PIT-tags would be used to provide in-river survival data during smolt outmigrations and coded-wire tags (CWT) used to provide adult return information. This report provides statistical models for the analysis of the joint data as well as recommendations on optimal tagging studies. Study costs and stress on smolt can be reduced by only PIT-tagging a subset of all the fish coded-wire-tagged, while retaining the information content and sampling precision

  13. Study to Determine the Biological Feasibility of a New Fish Tagging System : Annual Report 1983.

    Energy Technology Data Exchange (ETDEWEB)

    Prentice, Earl F.; Park, D.L.

    1984-05-01

    Pacific salmon are tagged or marked as a critical part of numerous research and management studies. A new tag called the PIT (passive integrated transponder) tag measuring 7.5 mm long by 1.5 mm in diameter has a great potential for marking fish if it proves to be biologically compatible. A study was conducted to evaluate the potential of the PIT tag for marking salmonids. The objectives of the first year's research were to determine: (1) the anatomical areas in which the tag could be placed; (2) tissue response to the tag; and (3) tag retention. Juvenile coho, Oncorhynchus kisutch, and chinook O. tshawytscha, salmon and adult chinook salmon held at Manchester or Big Beef Creek, Washington, were used as test animals. Juvenile salmon were injected with sham PIT tags in the body cavity and opercular, dorsal, and caudal masculature. The fish ranged in length from 126 to 212 mm. Observations based on three tests, from 44 to 102 days long, indicated that the dorsal musculature and body cavity were the best locations to inject the tag from biological and social standpoints. Sham PIT tags were injected into the nose; body cavity; and opercular, dorsal, and caudal musculature of jack chinook salmon. The test was conducted for 23 days. Although all five anatomical areas were acceptable from a technical standpoint, the body cavity appeared to be the best area for tag placement. Initial test results with the Sham PIT tag were very encouraging. Apparently the PIT tag can be successfully injected into and carried by salmon, making it a potentially useful tool for fisheries biologists. 5 refs., 8 figs., 6 tabs.

  14. Fall Chinook Salmon Survival and Supplementation Studies in the Snake River Reservoirs, 1996 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Williams, John G.; Bjornn (Bjomn), Theodore C.

    1998-05-01

    In 1996, the National Marine Fisheries Service, the Nez Perce Tribe, and the U.S. Fish and Wildlife Service completed the second year of cooperative research to investigate migrational characteristics of subyearling fall chinook salmon in the Snake River Basin. In spring and early summer, we captured natural subyearling fall chinook salmon by beach seine, PIT tagged them, and released them in two reaches of the Snake River. Also, subyearling fall chinook salmon reared at Lyons Ferry Hatchery were PIT tagged at the hatchery, transported, and released weekly at Pittsburg Landing on the Snake River and Big Canyon Creek on the Clearwater River to collect data on survival detection probabilities, and travel time.

  15. Radiofrequency identification technology and sea turtles

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This study investigated the compatibility of various PIT tag scanner technologies and available PIT tag frequencies, as well as testing the read depth potential of...

  16. Survival Estimates for the Passage of Spring-Migrating Juvenile Salmonids through Snake and Columbia River Dams and Reservoirs, 2001-2002 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Zabel, Richard; Williams, John G.; Smith, Steven G. (Northwest and Alaska Fisheries Science Center, Fish Ecology Division, Seattle, WA)

    2002-06-01

    In 2001, the National Marine Fisheries Service and the University of Washington completed the ninth year of a study to estimate survival and travel time of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake and Columbia Rivers. All estimates were derived from passive integrated transponder (PIT)-tagged fish. We PIT tagged and released at Lower Granite Dam a total of 17,028 hatchery and 3,550 wild steelhead. In addition, we utilized fish PIT tagged by other agencies at traps and hatcheries upstream of the hydropower system and sites within the hydropower system. PIT-tagged smolts were detected at interrogation facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day, and Bonneville Dams and in the PIT-tag detector trawl operated in the Columbia River estuary. Survival estimates were calculated using the Single-Release Model. Primary research objectives in 2001 were to: (1) estimate reach and project survival and travel time in the Snake and Columbia Rivers throughout the yearling chinook salmon and steelhead migrations; (2) evaluate relationships between survival estimates and migration conditions; and (3) evaluate the survival-estimation models under prevailing conditions. This report provides reach survival and travel time estimates for 2001 for PIT-tagged yearling chinook salmon and steelhead (hatchery and wild) in the Snake and Columbia Rivers. Results are reported primarily in the form of tables and figures with a minimum of text. More details on methodology and statistical models used are provided in previous reports cited in the text. Results for summer-migrating chinook salmon will be reported separately.

  17. Introduction to SURPH.1 analysis of release-recapture data for survival studies

    International Nuclear Information System (INIS)

    Smith, S.G.; Skalski, J.R.; Schlechte, J.W.; Hoffmann, A.; Cassen, V.

    1994-12-01

    Program SURPH is the culmination of several years of research to develop a comprehensive computer program to analyze survival studies of fish and wildlife populations. Development of this software was motivated by the advent of the PIT-tag (Passive Integrated Transponder) technology that permits the detection of salmonid smolt as they pass through hydroelectric facilities on the Snake and Columbia Rivers in the Pacific Northwest. Repeated detections of individually tagged smolt and analysis of their capture-histories permits estimates of downriver survival probabilities. Eventual installation of detection facilities at adult fish ladders will also permit estimation of ocean survival and upstream survival of returning salmon using the statistical methods incorporated in SURPH.1. However, the utility of SURPH.1 far exceeds solely the analysis of salmonid tagging studies. Release-recapture and radiotelemetry studies from a wide range of terrestrial and aquatic species have been analyzed using SURPH.1 to estimate discrete time survival probabilities and investigate survival relationships. The interactive computing environment of SURPH.1 was specifically developed to allow researchers to investigate the relationship between survival and capture processes and environmental, experimental and individual-based covariates. Program SURPH.1 represents a significant advancement in the ability of ecologists to investigate the interplay between morphologic, genetic, environmental and anthropogenic factors on the survival of wild species. It is hoped that this better understanding of risk factors affecting survival will lead to greater appreciation of the intricacies of nature and to improvements in the management of wild resources. This technical report is an introduction to SURPH.1 and provides a user guide for both the UNIX and MS-Windows reg-sign applications of the SURPH software

  18. Steelhead Supplementation Studies in Idaho Rivers: To evaluate the feasibility of using artificial production to increase natural steelhead populations and to collect baseline life history, genetic, and disease data from natural steelhead populations. 1993 Annual report

    International Nuclear Information System (INIS)

    Byrne, A.

    1996-01-01

    The Steelhead Supplementation Study was designed to evaluate the feasibility of using artificial production to increase natural steelhead Oncorhynchus mykiss populations and to collect baseline life history, genetic, and disease data from natural steelhead populations. To evaluate supplementation, the authors focused their experimental design on post-release survival, reproductive success, long-term fitness, and ecological interactions. They began field experiments in 1993 by outplanting hatchery adults and fingerlings to assess reproductive fitness and long-term survival. They snorkeled eight streams to estimate juvenile steelhead densities, recorded temperatures in 17 streams, and tagged natural steelhead in six streams with Passive Integrated Transponder (PIT) tags

  19. Idaho supplementation studies. Annual progress report, January 1--December 31, 1993

    International Nuclear Information System (INIS)

    Leitzinger, E.J.; Plaster, K.; Hassemer, P.; Sankovich, P.

    1996-12-01

    Idaho Supplementation Studies (ISS) will help determine the utility of supplementation as a potential recovery tool for decimated stocks of spring and summer chinook salmon, Oncorhynchus tshawytscha, in Idaho as part of a program to protect, mitigate, and enhance fish and wildlife affected by the development and operation of hydroelectric power plants on the Columbia River. The objectives are to: (1) monitor and evaluate the effects of supplementation on presmolt and smolt numbers and spawning escapements of naturally produced salmon; (2) monitor and evaluate changes in natural productivity and genetic composition of target and adjacent populations following supplementation; and (3) determine which supplementation strategies provide the quickest and highest response in natural production without adverse effects on productivity. Field work began in 1991 with the collection of baseline data from treatment and some control streams. Full implementation began in 1992 with baseline data collection on treatment and control streams and releases of supplementation fish into several treatment streams. Field methods included snorkeling to estimate chinook salmon parr populations, PIT tagging summer parr to estimate parr-to-smolt survival, multiple redd counts to estimate spawning escapement and collect carcass information. Screw traps were used to trap and PIT tag outmigrating chinook salmon during the spring and fall outmigration. Weirs were used to trap and enumerate returning adult salmon in select drainages

  20. Numerical Study on POSRV Leak Detection

    International Nuclear Information System (INIS)

    Ko, Yong Sang; Baik, Se Jin; Cho, Yoon Jae; Yune, Seok Jeong; Kim, Eun Kee

    2015-01-01

    This study shows that the selected temperature measuring locations on the discharge lines of MV, MOPV, SLPV0 and SLPV1 are adequate for POSRV leakage detection. The analyzed temperature can be used as an alarm setpoint for leakage detection. Spring-Loaded Pilot Valve (SLPV) acts as a Reactor Coolant Pressure Boundary (RCPB) isolator in the closed position during the normal operation, but it opens automatically when the system pressure increases to its set pressure. The POSRVs shall be closed tightly to maintain the integrity of RCPB during the normal operation. Leakage through the RCPB is limited extremely. Each POSRV has several discharge lines for MV and auxiliary valves. Temperature instruments are installed on each discharge lines for leakage detection. In this study, Computational Fluid Dynamics (CFD) analyses using FLUENT are conducted to evaluate the temperature measurement for POSRV leakage detection. The followings are concluded from this study: 1) The determined temperature measuring points are adequate for effective leak detection, which are at the downstream of the first bend of each discharge line as close as to the discharge nozzle. 2) The alarm set point for detecting a leak is adequate and can be determined with considering the analysis results. 3) The temperature rise is sufficiently high to detect a small leakage. 4) The temperature sensing method is appropriate for finding a valve leakage

  1. COMPARATIVE STUDY ON SPECIFIC AND EARLY DETECTION ...

    African Journals Online (AJOL)

    The objective of this study was to compare the sensitivity and specificity of smear and culture methods with rapid serological EIA myco kits manufactured by Omega diagnostics, for the early detection of Mycobacterium tuberculosis (MTB) complex. Sera from various categories of smear and culture results were compared ...

  2. Failure detection studies by layered neural network

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Seker, S.; Turkcan, E.

    1991-06-01

    Failure detection studies by layered neural network (NN) are described. The particular application area is an operating nuclear power plant and the failure detection is of concern as result of system surveillance in real-time. The NN system is considered to be consisting of 3 layers, one of which being hidden, and the NN parameters are determined adaptively by the backpropagation (BP) method, the process being the training phase. Studies are performed using the power spectra of the pressure signal of the primary system of an operating nuclear power plant of PWR type. The studies revealed that, by means of NN approach, failure detection can effectively be carried out using the redundant information as well as this is the case in this work; namely, from measurement of the primary pressure signals one can estimate the primary system coolant temperature and hence the deviation from the operational temperature state, the operational status identified in the training phase being referred to as normal. (author). 13 refs.; 4 figs.; 2 tabs

  3. The design and analysis of salmonid tagging studies in the Columbia Basin. Volume 10: Instructional guide to using program CaptHist to create SURPH files for survival analysis using PTAGIS data files

    International Nuclear Information System (INIS)

    Westhagen, P.; Skalski, J.

    1997-12-01

    The SURPH program is a valuable tool for estimating survivals and capture probabilities of fish outmigrations on the Snake and Columbia Rivers. Using special data files, SURPH computes reach to reach statistics for any release group passing a system of detection sites. Because the data must be recorded for individual fish, PIT tag data is best suited for use as input. However, PIT tag data as available from PTAGIS comes in a form that is not ready for use as SURPH input. SURPH requires a capture history for each fish. A capture history consists of a series of fields, one for each detection site, that has a code for whether the fish was detected and returned to the river, detected and removed, or not detected. For the PTAGIS data to be usable by SURPH it must be pre-processed. The data must be condensed down to one line per fish with the relevant detection information from the PTAGIS file represented compactly on each line. In addition, the PTAGIS data file coil information must be passed through a series of logic algorithms to determine whether or not a fish is returned to the river after detection. Program CaptHist was developed to properly pre-process the PTAGIS data files for input to program SURPH. This utility takes PTAGIS data files as input and creates a SURPH data file as well as other output including travel time records, detection date records, and a data error file. CaptHist allows a user to download PTAGIS files and easily process the data for use with SURPH

  4. Summary of PWR leak detection studies

    International Nuclear Information System (INIS)

    Cho, J.H.; Elia, F.A. Jr.

    1986-01-01

    Thermal-hydraulic analysis can be used to determine the location and magnitude of leaks inside and location of leaks outside a pressurized water reactor (PWR) containment as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside containment. Plant-specific analyses are utilized to predict change in parameters such as local dew point temperature, relative humidity, dry bulb temperature, and flow rate to sump for various leak rates and enthalpies. These parameter responses are then programmed into the plant computer and instrumentation is provided for area monitoring. The actual inputs are continuously monitored and compared to the predicted plant responses to identify the leak location and quantify the leak. This study concludes that a system that monitors dew point (or relative humidity) and dry bulb temperature changes together with the flow rate to the sump will provide the capability to both locate and quantify a leak inside a containment, while a system that monitors dew point temperature (or relative humidity) changes will provide the capability to locate a leak outside a containment

  5. Estimating disperser abundance using open population models that incorporate data from continuous detection PIT arrays

    Science.gov (United States)

    Dzul, Maria C.; Yackulic, Charles B.; Korman, Josh

    2017-01-01

    Autonomous passive integrated transponder (PIT) tag antenna systems continuously detect individually marked organisms at one or more fixed points over long time periods. Estimating abundance using data from autonomous antennae can be challenging, because these systems do not detect unmarked individuals. Here we pair PIT antennae data from a tributary with mark-recapture sampling data in a mainstem river to estimate the number of fish moving from the mainstem to the tributary. We then use our model to estimate abundance of non-native rainbow trout Oncorhynchus mykiss that move from the Colorado River to the Little Colorado River (LCR), the latter of which is important spawning and rearing habitat for federally-endangered humpback chub Gila cypha. We estimate 226 rainbow trout (95% CI: 127-370) entered the LCR from October 2013-April 2014. We discuss the challenges of incorporating detections from autonomous PIT antenna systems into mark-recapture population models, particularly in regards to using information about spatial location to estimate movement and detection probabilities.

  6. Detect and Avoid (DAA) Automation Maneuver Study

    Science.gov (United States)

    2017-02-01

    GUY A. FRENCH JOSEPH C. PRICE, MAJ, USAF Work Unit Manager Acting Chief, Supervisory Control and Cognition Branch Supervisory Control and Cognition...19a. NAME OF RESPONSIBLE PERSON (Monitor) a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified Guy French 19b. TELEPHONE...the ability to detect and safely avoid other aircraft in flight ( Cook & Davis, 2013). In order to increase UAS flight safety and support UAS

  7. Detectable perfusion changes in MAG3 studies

    International Nuclear Information System (INIS)

    Shuter, B.; Bernar, A.; Roach, P.

    1998-01-01

    Full text: The use of 120 MBq 99m Tc-MAG 3 instead of 600 MBq 99m Tc-DTPA in renal imaging has degraded the images obtained during the perfusion phase. An increase of the minimum detectable change (MDC) in blood flow (BF) would also be expected. In transplant patients, renal BF is an important factor in patient management and the MDC should be small to allow early detection of reduced perfusion. We determined the mean and coefficient of variation (CoV: standard deviation/mean) of three renal perfusion indices as a function of counts in the time-activity curves (TACs). Transplant patients were given a dose of about 300 MBq of 99m Tc-MAG3 and images acquired at 8 fps for 60s. TACs made up from 8, 4, 2 or I images per second allowed calculation of renal perfusion indices as if doses of 300, 150, 75 and 38 MBq had been administered. Perfusion indices based on area under the TACs up to the arterial peak (API), the maximum slopes of the TACs (SPI) and the maximum slope of renal TAC and height of arterial TAC (BPI) were calculated by our routine renal software package. As the administered dose decreased, the CoV rose for all indices, least for BPI and most for API. BPI CoV increased from ∼10% at 300 MBq to 20% at 75 MBq, but API CoV rose from 6% to 46%. Mean BPI was stable over the dose range, but mean API showed a systematic increase of about 50% over the 300 MBq result. We conclude that at 120 MBq the MDC (expressed as 2*CoV) in BF is 30-60%, whereas at 600 MBq it may be as low as 10%, allowing earlier confident detection of a change in BF. The BPI was the preferred perfusion index as its mean value changed little and it had the least CoV at lower activities. The data also imply that relative kidney perfusion in the one individual will be much less accurate with 120 MBq of MAG 3

  8. Wildlife Contact Rates at Artificial Feeding Sites in Texas

    Science.gov (United States)

    Campbell, Tyler A.; Long, David B.; Shriner, Susan A.

    2013-06-01

    Given the popularity of feeding white-tailed deer ( Odocoileus virginianus) in Texas and the increasing amount of corn that is distributed, more information is needed on the impacts of this activity on non-target wildlife. Our objectives were to report visitation, intra- and interspecific contact, and contact rates of wildlife at artificial feeding sites in Texas. Our study was conducted at three sites in Kleberg and Nueces counties, Texas. We trapped animals from February to April and August to September, 2009 and marked animals with passive integrated transponder (PIT) tags. At each site and season, we placed one feeder system containing a PIT tag reader within 600 m of trap locations. Readers detected PIT tags from a distance of 25 cm. We determined a contact event to occur when two different PIT tags were detected by feeder systems within 5 s. We recorded 62,719 passes by raccoons ( Procyon lotor), 103,512 passes by collared peccaries ( Pecari tajacu), 2,923 passes by feral swine ( Sus scrofa), 1,336 passes by fox squirrels ( Sciurus niger), and no passes by opossums ( Didelphis virginiana) at feeder systems. For site-season combinations in which contact events occurred, we found intraspecific contact rates (contacts per day) for raccoons, collared peccaries, and feral swine to be 0.81-124.77, 0.69-38.08, and 0.0-0.66, respectively. Throughout our study we distributed ~2,625 kg of whole kernel corn, which resulted in 6,351 contact events between marked wildlife (2.4 contacts per kg of corn). If 136 million kg of corn is distributed in Texas annually, we would expect >5.2 billion unnatural contact events between wildlife would result from this activity each year in Texas. Consequently, we do not believe that it is wise for natural resource managers to maintain artificial feeding sites for white-tailed deer or other wildlife due to pathogen transmission risks.

  9. A study of malware detection on smart mobile devices

    Science.gov (United States)

    Yu, Wei; Zhang, Hanlin; Xu, Guobin

    2013-05-01

    The growing in use of smart mobile devices for everyday applications has stimulated the spread of mobile malware, especially on popular mobile platforms. As a consequence, malware detection becomes ever more critical in sustaining the mobile market and providing a better user experience. In this paper, we review the existing malware and detection schemes. Using real-world malware samples with known signatures, we evaluate four popular commercial anti-virus tools and our data shows that these tools can achieve high detection accuracy. To deal with the new malware with unknown signatures, we study the anomaly based detection using decision tree algorithm. We evaluate the effectiveness of our detection scheme using malware and legitimate software samples. Our data shows that the detection scheme using decision tree can achieve a detection rate up to 90% and a false positive rate as low as 10%.

  10. A comprehensive study of sparse codes on abnormality detection

    DEFF Research Database (Denmark)

    Ren, Huamin; Pan, Hong; Olsen, Søren Ingvor

    2017-01-01

    Sparse representation has been applied successfully in abnor-mal event detection, in which the baseline is to learn a dic-tionary accompanied by sparse codes. While much empha-sis is put on discriminative dictionary construction, there areno comparative studies of sparse codes regarding abnormal-ity...... detection. We comprehensively study two types of sparsecodes solutions - greedy algorithms and convex L1-norm so-lutions - and their impact on abnormality detection perfor-mance. We also propose our framework of combining sparsecodes with different detection methods. Our comparative ex-periments are carried...

  11. Studying Irony Detection Beyond Ironic Criticism: Let's Include Ironic Praise

    Directory of Open Access Journals (Sweden)

    Richard Bruntsch

    2017-04-01

    Full Text Available Studies of irony detection have commonly used ironic criticisms (i.e., mock positive evaluation of negative circumstances as stimulus materials. Another basic type of verbal irony, ironic praise (i.e., mock negative evaluation of positive circumstances is largely absent from studies on individuals' aptitude to detect verbal irony. However, it can be argued that ironic praise needs to be considered in order to investigate the detection of irony in the variety of its facets. To explore whether the detection ironic praise has a benefit beyond ironic criticism, three studies were conducted. In Study 1, an instrument (Test of Verbal Irony Detection Aptitude; TOVIDA was constructed and its factorial structure was tested using N = 311 subjects. The TOVIDA contains 26 scenario-based items and contains two scales for the detection of ironic criticism vs. ironic praise. To validate the measurement method, the two scales of the TOVIDA were experimentally evaluated with N = 154 subjects in Study 2. In Study 3, N = 183 subjects were tested to explore personality and ability correlates of the two TOVIDA scales. Results indicate that the co-variance between the ironic TOVIDA items was organized by two inter-correlated but distinct factors: one representing ironic praise detection aptitude and one representing ironic criticism detection aptitude. Experimental validation showed that the TOVIDA items truly contain irony and that item scores reflect irony detection. Trait bad mood and benevolent humor (as a facet of the sense of humor were found as joint correlates for both ironic criticism and ironic praise detection scores. In contrast, intelligence, trait cheerfulness, and corrective humor were found as unique correlates of ironic praise detection scores, even when statistically controlling for the aptitude to detect ironic criticism. Our results indicate that the aptitude to detect ironic praise can be seen as distinct from the aptitude to detect ironic

  12. Contribution to the physical study of sheath failure detections

    International Nuclear Information System (INIS)

    Mangin, Jean-Paul

    1968-11-01

    As the study of an installation aimed at the detection of sheath failure requires the knowledge of a great number of data related to all the fields of nuclear technology (fission mechanisms, sheath failure mechanisms, recoil of fission products, distribution of the heat transfer fluid in the reactor, techniques of measurement of beta and gamma neutrons, nuclear safety, and so on), this report aims at highlighting some specific issues, more particularly those related to sensors based on delayed neutrons. After having recalled the principles of sheath failure detection, the author presents the various aspects of the study of the formation of fission products and of their passage into the heat transfer fluid: detection by using delayed neutrons, detection by electrostatic collection, passage of fuel fission products into the coolant (recoil, corrosion, gaseous diffusion in the fuel), formation of fission products in the fuel (fission product efficiency). He reports the study of the transport of fission products by the coolant from their place of birth to the place of measurement. He presents the system of measurement by detection of delayed neutrons and by electrostatic collection, reports a sensitivity calculation, a background noise assessment, the determination of detection threshold, and the application of sensitivity and detection thresholds calculations [fr

  13. A simulation study comparing aberration detection algorithms for syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Painter Ian

    2007-03-01

    Full Text Available Abstract Background The usefulness of syndromic surveillance for early outbreak detection depends in part on effective statistical aberration detection. However, few published studies have compared different detection algorithms on identical data. In the largest simulation study conducted to date, we compared the performance of six aberration detection algorithms on simulated outbreaks superimposed on authentic syndromic surveillance data. Methods We compared three control-chart-based statistics, two exponential weighted moving averages, and a generalized linear model. We simulated 310 unique outbreak signals, and added these to actual daily counts of four syndromes monitored by Public Health – Seattle and King County's syndromic surveillance system. We compared the sensitivity of the six algorithms at detecting these simulated outbreaks at a fixed alert rate of 0.01. Results Stratified by baseline or by outbreak distribution, duration, or size, the generalized linear model was more sensitive than the other algorithms and detected 54% (95% CI = 52%–56% of the simulated epidemics when run at an alert rate of 0.01. However, all of the algorithms had poor sensitivity, particularly for outbreaks that did not begin with a surge of cases. Conclusion When tested on county-level data aggregated across age groups, these algorithms often did not perform well in detecting signals other than large, rapid increases in case counts relative to baseline levels.

  14. Canine scent detection of canine cancer: a feasibility study

    OpenAIRE

    Dorman,David; Foster,Melanie; Fernhoff,Katherine; Hess,Paul

    2017-01-01

    David C Dorman,1 Melanie L Foster,2 Katherine E Fernhoff,1 Paul R Hess2 1Department of Molecular and Biomedical Sciences, 2Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, USA Abstract: The scent detection prowess of dogs has prompted interest in their ability to detect cancer. The purpose of this study was to determine whether dogs could use olfactory cues to discriminate urine samples collected from dogs that did or did not have ...

  15. Nanobarcoding for improved nanoparticle detection in nanomedical biodistribution studies

    Science.gov (United States)

    Eustaquio, Trisha

    Determination of the fate of nanoparticles (NPs) in a biological system, or NP biodistribution, is critical in evaluating a NP formulation for nanomedicine. Unlike small-molecule drugs, NPs impose unique challenges in the design of appropriate biodistribution studies due to their small size and subsequent detection signal. Current methods to determine NP biodistribution are greatly inadequate due to their limited detection thresholds. There is an overwhelming need for a sensitive and efficient imaging-based method that can (1) detect and measure small numbers of NPs of various types, ideally single NPs, (2) associate preferential NP uptake with histological cell type by preserving spatial information in samples, and (3) allow for relatively quick and accurate NP detection in in vitro (and possibly ex vivo) samples for comprehensive NP biodistribution studies. Herein, a novel method for improved NP detection is proposed, coined "nanobarcoding." Nanobarcoding utilizes a non-endogenous oligonucleotide, or "nanobarcode" (NB), conjugated to the NP surface to amplify the detection signal from a single NP via in situ polymerase chain reaction (ISPCR), and this signal amplification will facilitate rapid and precise detection of single NPs inside cells over large areas of sample such that more sophisticated studies can be performed on the NP-positive subpopulation. Moreover, nanobarcoding has the potential to be applied to the detection of more than one NP type to study the effects of physicochemical properties, targeting mechanisms, and route of entry on NP biodistribution. The nanobarcoding method was validated in vitro using NB-functionalized superparamagnetic iron oxide NPs (NB-SPIONs) as the model NP type for improved NP detection inside HeLa human cervical cancer cells, a cell line commonly used for ISPCR-mediated detection of human papilloma virus (HPV). Nanotoxicity effects of NB-SPIONs were also evaluated at the single-cell level using LEAP (Laser-Enabled Analysis

  16. Scientific Uncertainties in Climate Change Detection and Attribution Studies

    Science.gov (United States)

    Santer, B. D.

    2017-12-01

    It has been claimed that the treatment and discussion of key uncertainties in climate science is "confined to hushed sidebar conversations at scientific conferences". This claim is demonstrably incorrect. Climate change detection and attribution studies routinely consider key uncertainties in observational climate data, as well as uncertainties in model-based estimates of natural variability and the "fingerprints" in response to different external forcings. The goal is to determine whether such uncertainties preclude robust identification of a human-caused climate change fingerprint. It is also routine to investigate the impact of applying different fingerprint identification strategies, and to assess how detection and attribution results are impacted by differences in the ability of current models to capture important aspects of present-day climate. The exploration of the uncertainties mentioned above will be illustrated using examples from detection and attribution studies with atmospheric temperature and moisture.

  17. THE ACOUSTIC DETECTION OF INTRACRANIAL ANEURYSMS - A CLINICAL-STUDY

    NARCIS (Netherlands)

    VANBRUGGEN, AC; MOOIJ, JJA; JOURNEE, HL

    1991-01-01

    A new recording method for the acoustical detection of intracranial aneurysms is presented. A study examining the capability of the method to discriminate between patients with an aneurysm and control patients by a simple, objective parameter is reported. Sound signals were recorded over the eyes,

  18. Soybean allergen detection methods--a comparison study

    DEFF Research Database (Denmark)

    Pedersen, M. Højgaard; Holzhauser, T.; Bisson, C.

    2008-01-01

    Soybean containing products are widely consumed, thus reliable methods for detection of soy in foods are needed in order to make appropriate risk assessment studies to adequately protect soy allergic patients. Six methods were compared using eight food products with a declared content of soy...

  19. Quench detection, protection and simulation studies on SST-1 magnets

    International Nuclear Information System (INIS)

    Sharma, Aashoo N.; Khristi, Yohan; Pradhan, Subrata; Doshi, Kalpesh; Prasad, Upendra; Banaudha, Moni; Varmora, Pankaj; Praghi, Bhadresh R.

    2015-01-01

    Steady-state Superconducting Tokamak-1 (SST-1) is India's first tokamak with superconducting toroidal field (TF) and Poloidal Field (PF) magnets. These magnets are made with NbTi based Cable-In-Conduit-Conductors. The quench characteristic of SST-1 CICC has been extensively studied both analytically and using simulation codes. Dedicated experiments like model coil test program, TF coil test program and laboratory experiments were conducted to fully characterize the performance of the CICC and the magnets made using this CICC. Results of quench experiments performed during these tests have been used to design the SST-1 quench detection and protection system. Simulation results of TF coil quenches and slow propagation quench of TF busbars have been used to further optimize these systems during the SST-1 tokamak operation. Redundant hydraulic based quench detection is also proposed for the TF coil quench detection. This paper will give the overview of these development and simulation activities. (author)

  20. Fall detection using supervised machine learning algorithms: A comparative study

    KAUST Repository

    Zerrouki, Nabil; Harrou, Fouzi; Houacine, Amrane; Sun, Ying

    2017-01-01

    Fall incidents are considered as the leading cause of disability and even mortality among older adults. To address this problem, fall detection and prevention fields receive a lot of intention over the past years and attracted many researcher efforts. We present in the current study an overall performance comparison between fall detection systems using the most popular machine learning approaches which are: Naïve Bayes, K nearest neighbor, neural network, and support vector machine. The analysis of the classification power associated to these most widely utilized algorithms is conducted on two fall detection databases namely FDD and URFD. Since the performance of the classification algorithm is inherently dependent on the features, we extracted and used the same features for all classifiers. The classification evaluation is conducted using different state of the art statistical measures such as the overall accuracy, the F-measure coefficient, and the area under ROC curve (AUC) value.

  1. Fall detection using supervised machine learning algorithms: A comparative study

    KAUST Repository

    Zerrouki, Nabil

    2017-01-05

    Fall incidents are considered as the leading cause of disability and even mortality among older adults. To address this problem, fall detection and prevention fields receive a lot of intention over the past years and attracted many researcher efforts. We present in the current study an overall performance comparison between fall detection systems using the most popular machine learning approaches which are: Naïve Bayes, K nearest neighbor, neural network, and support vector machine. The analysis of the classification power associated to these most widely utilized algorithms is conducted on two fall detection databases namely FDD and URFD. Since the performance of the classification algorithm is inherently dependent on the features, we extracted and used the same features for all classifiers. The classification evaluation is conducted using different state of the art statistical measures such as the overall accuracy, the F-measure coefficient, and the area under ROC curve (AUC) value.

  2. [Study on spectral detection of green plant target].

    Science.gov (United States)

    Deng, Wei; Zhao, Chun-jiang; He, Xiong-kui; Chen, Li-ping; Zhang, Lu-da; Wu, Guang-wei; Mueller, J; Zhai, Chang-yuan

    2010-08-01

    Weeds grow scatteredly in fields, where many insentient objects exist, for example, withered grasses, dry twig and barriers. In order to improve the precision level of spraying, it is important to study green plant detecting technology. The present paper discussed detecting method of green plant by using spectral recognizing technology, because of the real-time feature of spectral recognition. By analyzing the reflectivity difference between each of the two sides of the "red edge" of the spectrum from plants and surrounding environment, green plant discriminat index (GPDI) is defined as the value which equals the reflectivity ratio at the wavelength of 850 nm divided by the reflectivity ratio at the wavelength of 650 nm. The original spectral data of green plants and the background were measured by using the handhold FieldSpec 3 Spectroradiometer manufactured by ASD Inc. in USA. The spectral data were processed to get the reflectivity of each measured objects and to work out the GPDI thereof as well. The classification model of green plant and its background was built up using decision tree method in order to obtain the threshold of GPDI to distinguish green plants and the background. The threshold of GPDI was chosen as 5.54. The detected object was recognized as green plant when it is GPDI>GPDITH, and vice versa. Through another test, the accuracy rate was verified which was 100% by using the threshold. The authors designed and developed the green plant detector based on single chip microcomputer (SCM) "AT89S51" and photodiode "OPT101" to realize detecting green plants from the background. After passing through two optical filters, the center wavelengths of which are 650 and 850 nm respectively, the reflected light from measured targets was detected by two photodiodes and converted into electrical signals. These analog signals were then converted to digital signals via an analog-to-digital converter (ADS7813) after being amplified by a signal amplifier (OP400

  3. Wave study of compound eyes for efficient infrared detection

    Science.gov (United States)

    Kilinc, Takiyettin Oytun; Hayran, Zeki; Kocer, Hasan; Kurt, Hamza

    2017-08-01

    Improving sensitivity in the infrared spectrum is a challenging task. Detecting infrared light over a wide bandwidth and at low power consumption is very important. Novel solutions can be acquired by mimicking biological eyes such as compound eye with many individual lenses inspired from the nature. The nature provides many ingenious approaches of sensing and detecting the surrounding environment. Even though compound eye consists of small optical units, it can detect wide-angle electromagnetic waves and it has high transmission and low reflection loss. Insects have eyes that are superior compared to human eyes (single-aperture eyes) in terms of compactness, robustness, wider field of view, higher sensitivity of light intensity and being cheap vision systems. All these desired properties are accompanied by an important drawback: lower spatial resolution. The first step to investigate the feasibility of bio-inspired optics in photodetectors is to perform light interaction with the optical system that gather light and detect it. The most common method used in natural vision systems is the ray analysis. Light wave characteristics are not taken into consideration in such analyses, such as the amount of energy at the focal point or photoreceptor site, the losses caused by reflection at the interfaces and absorption cannot be investigated. In this study, we present a bio-inspired optical detection system investigated by wave analysis. We numerically model the wave analysis based on Maxwell equations from the viewpoint of efficient light detection and revealing the light propagation after intercepting the first interface of the eye towards the photoreceptor site.

  4. An exploration study to detect important factors influencing insurance firms

    Directory of Open Access Journals (Sweden)

    Farzaneh Soleimani

    2013-11-01

    Full Text Available The recent trend on competition among insurance firms has increased motivation to look for important factors influencing this industry. In this paper, we present an empirical investigation to find important factors shaping this industry. The proposed study designs a questionnaire in Likert scale and, using principal component analysis, detects important factors on the success of this industry. Cronbach alpha is calculated as 0.849, and Kaiser-Meyer-Olkin and Bartlett's Test are calculated as 0.873 and 12744 with (Sig. =0.000, respectively. The study has detected four important factors including quality of service casualties, sales improvement and advertisement, quality of issuance of insurance policies and quality of work force.

  5. Studies on neutron detection with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Khouri, M.C.; Vilela, E.C.; Andrade, C. de.

    1993-03-01

    The detection of thermal and fast neutrons was studied. For thermal neutrons, alpha sensitive plastic was used in order to register the products of nuclear reactions taking place in boron and /or lithium converters. Fast neutrons produce recoil tracks within the detector. In the present case, CR-39 and Makrofol E were used. Chemical and electrochemical etching processes were used for thermal and fast neutron detectors, respectively. (F.E.). 6 refs, 4 figs, 6 tabs

  6. An exploration study to detect important factors influencing insurance firms

    OpenAIRE

    Farzaneh Soleimani; Fattaneh Alizadeh Meshkani; Abdullah Naami

    2013-01-01

    The recent trend on competition among insurance firms has increased motivation to look for important factors influencing this industry. In this paper, we present an empirical investigation to find important factors shaping this industry. The proposed study designs a questionnaire in Likert scale and, using principal component analysis, detects important factors on the success of this industry. Cronbach alpha is calculated as 0.849, and Kaiser-Meyer-Olkin and Bartlett's Test are calculated as ...

  7. Methow River Studies, Washington: abundance estimates from Beaver Creek and the Chewuch River screw trap, methodology testing in the Whitefish Island side channel, and survival and detection estimates from hatchery fish releases, 2013

    Science.gov (United States)

    Martens, Kyle D.; Fish, Teresa M.; Watson, Grace A.; Connolly, Patrick J.

    2014-01-01

    , leaving one large pool near the bottom of the side channel and several shallow isolated pools that may or may not go dry. In seasonally connected side channels, juvenile salmonid survival in pools less than 100 cm average depth was lower than in pools greater than 100 cm average depth (Martens and Connolly, 2014). In this report, we document our field work and analysis completed in 2013. During 2013, USGS sampling efforts were focused on resampling of three reaches in Beaver Creek, testing methodology in the Whitefish Island side channel, conducting hatchery survival estimates, and operating a screw trap on the Chewuch River (funded by Yakama Nation; fig. 1). The Beaver Creek sampling effort was a revisit of three index sites sampled continuously from 2004 to 2007 to look at the fish response to barrier removal. Methodology testing in Whitefish Island side channel was done to determine the best method for evaluating fish populations after restoration efforts in side channels (previous sampling methods were determined to be ineffective after pools were deepened). Hatchery survival estimates were completed to monitor fish survival in the Methow and Columbia Rivers, while the screw trap was operated to estimate migrating fish populations in the Chewuch River and track passive integrated transponder (PIT)-tagged fish. In addition, we maintained a network of PIT-tag interrogation systems (PTIS), assisted Reclamation with fish removal events associated with stream restoration (two people for 9 days; 14 percent of summer field season), and conducted a stream metabolism study designed to help parameterize and calibrate the stream productivity model (Bellmore and others, 2014) with model validation.

  8. Tricuspid insufficiency detected by equilibrium gated radionuclide study

    International Nuclear Information System (INIS)

    Handler, B.; Pavel, D.G.; Lam, W.; Byrom, E.; Swiryn, S.; Pietras, R.; Rosen, K.M.

    1981-01-01

    The results of a gated radionuclide cardiac study are reported in a patient with biventricular failure and tricuspid insufficiency demonstrated by clinical evaluation, M-mode and 2-D sector echocardiography, and cardia catheterization. The processed gated radionuclide cardiac study showed a left ventricular/right ventricular stroke volume ratio of 0.5; expansion of the hepatic blood pool demonstrated by hepatic time activity curve and calculation of an '''expansion fraction''; and synchronous changes of count rate of the atrial and hepatic regions detected by phase analysis

  9. Canine scent detection of canine cancer: a feasibility study

    Directory of Open Access Journals (Sweden)

    Dorman DC

    2017-10-01

    Full Text Available David C Dorman,1 Melanie L Foster,2 Katherine E Fernhoff,1 Paul R Hess2 1Department of Molecular and Biomedical Sciences, 2Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, USA Abstract: The scent detection prowess of dogs has prompted interest in their ability to detect cancer. The purpose of this study was to determine whether dogs could use olfactory cues to discriminate urine samples collected from dogs that did or did not have urinary tract transitional cell carcinoma (TCC, at a rate greater than chance. Dogs with previous scent training (n=4 were initially trained to distinguish between a single control and a single TCC-positive urine sample. All dogs acquired this task (mean =15±7.9 sessions; 20 trials/session. The next training phase used four additional control urine samples (n=5 while maintaining the one original TCC-positive urine sample. All dogs quickly acquired this task (mean =5.3±1.5 sessions. The last training phase used multiple control (n=4 and TCC-positive (n=6 urine samples to promote categorical training by the dogs. Only one dog was able to correctly distinguish multiple combinations of TCC-positive and control urine samples suggesting that it mastered categorical learning. The final study phase evaluated whether this dog would generalize this behavior to novel urine samples. However, during double-blind tests using two novel TCC-positive and six novel TCC-negative urine samples, this dog did not indicate canine TCC-positive cancer samples more frequently than expected by chance. Our study illustrates the need to consider canine olfactory memory and the use of double-blind methods to avoid erroneous conclusions regarding the ability of dogs to alert on specimens from canine cancer patients. Our results also suggest that sample storage, confounding odors, and other factors need to be considered in the design of future studies that evaluate the detection of

  10. Studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Hayashi, S.H.; Harasawa, S.; Tomura, K.

    1992-01-01

    Studies on fuel failure detection have been made since 1986 in Rikkyo Research Reactor. One of the methods is the monitoring of the trace concentration of fission products appearing in the air on the surface of the water tank of the reactor. The interested radionuclides here are 89 Rb and 138 Cs, which are the daughter nuclides of the FP rare gas nuclides, 89 Kr and 138 Xe, respectively and have the half lives of 15.2 min and 32.2 min respectively. They are detected on a filter paper attached on a conventional dust sampler, by sucking the air of the surface of the water for 15 ∼ 30 min during reactor operation (100 kW). In this presentation are reported the results of an attempt to increase the sensitivity of detecting these nuclides by introducing nitrogen gas bubbles into the water. The bubbling of the gas increased the sensitivity as much as several times compared with the case without bubbling. These measurements are giving us the 'background' concentration, the order of which is almost unchanged for these several years, --in 10 -6 Bq/cm 3 . The origin of these nuclides is considered to be not from the fuel but from the uranium contained as an impurity in the reactor material in the core. (author)

  11. Webcams for Bird Detection and Monitoring: A Demonstration Study

    Directory of Open Access Journals (Sweden)

    Willem W. Verstraeten

    2010-04-01

    Full Text Available Better insights into bird migration can be a tool for assessing the spread of avian borne infections or ecological/climatologic issues reflected in deviating migration patterns. This paper evaluates whether low budget permanent cameras such as webcams can offer a valuable contribution to the reporting of migratory birds. An experimental design was set up to study the detection capability using objects of different size, color and velocity. The results of the experiment revealed the minimum size, maximum velocity and contrast of the objects required for detection by a standard webcam. Furthermore, a modular processing scheme was proposed to track and follow migratory birds in webcam recordings. Techniques such as motion detection by background subtraction, stereo vision and lens distortion were combined to form the foundation of the bird tracking algorithm. Additional research to integrate webcam networks, however, is needed and future research should enforce the potential of the processing scheme by exploring and testing alternatives of each individual module or processing step.

  12. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  13. An exploration study to detect important barriers for knowledge management

    Directory of Open Access Journals (Sweden)

    Jalil Ghafourian

    2014-01-01

    Full Text Available This paper presents an empirical investigation to find the important factors influencing implementation of knowledge management in revenue agencies in Iran. The proposed study designs a questionnaire and distributes it among some experts and, using principal component analysis, the study detects important barriers for knowledge management implications. The study selects 170 people from 880 regular employees who work for revenue agency and distributes the questionnaire designed in Likert scale. Cronbach alpha has been determined as 0.70, which is well above the minimum acceptable level. In terms of knowledge management, the study determines six factors including support for creativity and innovation, knowledge sharing, trust, employee promotion plan, mission and training programs and they represent 66.57% of the described factors. In addition, in terms of barriers, job security, cultural issues, individual differences, infrastructure, organizational structure and lack of vision are the most important issues representing 61.98% of the factors.

  14. Sensitivity of MRI in detecting alveolar infiltrates. Experimental studies

    International Nuclear Information System (INIS)

    Biederer, J.; Busse, I.; Grimm, J.; Reuter, M.; Heller, M.; Muhle, C.; Freitag, S.

    2002-01-01

    Purpose: An experimental study using porcine lung explants and a dedicated chest phantom to evaluate the signal intensity of artificial alveolar infiltrates with T 1 - and T 2 -weighted MRI sequences. Material and Methods: 10 porcine lung explants were intubated, transferred into the cavity of a MRI-compatible chest phantom and inflated by continuous evacuation of the artificial pleural space. All lungs were examined with MRI at 1.5 T before and after intra-tracheal instillation of either 100 or 200 ml gelatine-stabilised liquid to simulate alveolar infiltrates. MR-examination comprised gradient echo (2D- and 3D-GRE) and fast spin echo sequences (T 2 -TSE and T 2 -HASTE). The signal intensity of lung parenchyma was evaluated at representative cross sections using a standardised scheme. Control studies were acquired with helical CT. Results: The instilled liquid caused patchy confluent alveolar infiltrates resembling the findings in patients with pneumonia or ARDS. CT revealed typical ground-glass opacities. Before the application of the liquid, only T 2 -HASTE and T 2 -TSE displayed lung parenchyma signals with a signal/noise ratio of 3.62 and 1.39, respectively. After application of the liquid, both T 2 -weighted sequences showed clearly visible infiltrates with an increase in signal intensity of approx. 30% at 100 ml (p 2 -weighted sequences detects artificial alveolar infiltrates with high signal intensity and may be a highly sensitive tool to detect pneumonia in patients. (orig.) [de

  15. Isotopically modified nanoparticles for enhanced detection in bioaccumulation studies

    Science.gov (United States)

    Misra, S.K.; Dybowska, A.; Berhanu, D.; Croteau, M.-N.; Luoma, S.N.; Boccaccini, A.R.; Valsami-Jones, E.

    2012-01-01

    This work presents results on synthesis of isotopically enriched (99% 65Cu) copper oxide nanoparticles and its application in ecotoxicological studies. 65CuO nanoparticles were synthesized as spheres (7 nm) and rods (7 ?? 40 nm). Significant differences were observed between the reactivity and dissolution of spherical and rod shaped nanoparticles. The extreme sensitivity of the stable isotope tracing technique developed in this study allowed determining Cu uptake at exposure concentrations equivalent to background Cu concentrations in freshwater systems (0.2-30 ??g/L). Without a tracer, detection of newly accumulated Cu was impossible, even at exposure concentrations surpassing some of the most contaminated water systems (>1 mg/L). ?? 2011 American Chemical Society.

  16. [Advance on study development of detection of ciguatoxins].

    Science.gov (United States)

    Yuan, Jianhui; Zhao, Kunshan; Zhuang, Zhixiong

    2007-11-01

    Ciguatoxin may be a terrible coral fish toxin that can result in poisoning in people who eat fish containing ciguatoxin. Being lack of a convenient and accurate detection method for ciguatoxin, Ciguatera fish poisoning have occurred from time to time. To provide references for detection and prevention of ciguatera fish poisoning, in this paper, the current detection methods of ciguatoxin were reviewed.

  17. Multivariate Alteration Detection (MAD) and MAF Postprocessing in Multispectral, Bitemporal Image Data: New Approaches to Change Detection Studies

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Conradsen, Knut; Simpson, James J.

    1998-01-01

    type analyses of simple difference images. Case studies with AHVRR and Landsat MSS data using simple linear stretching and masking of the change images show the usefulness of the new MAD and MAF/MAD change detection schemes. Ground truth observations confirm the detected changes. A simple simulation...

  18. Biological Detection System Technologies Technology and Industrial Base Study. A Primer on Biological Detection Technologies

    National Research Council Canada - National Science Library

    2001-01-01

    .... and Canadian military personnel. In light of these concerns both defense departments have increased efforts to develop and field biological agent detection systems to help protect their military forces and fixed assets...

  19. Detecting rare variants in case-parents association studies.

    Directory of Open Access Journals (Sweden)

    Kuang-Fu Cheng

    Full Text Available Despite the success of genome-wide association studies (GWASs in detecting common variants (minor allele frequency ≥0.05 many suggested that rare variants also contribute to the genetic architecture of diseases. Recently, researchers demonstrated that rare variants can show a strong stratification which may not be corrected by using existing methods. In this paper, we focus on a case-parents study and consider methods for testing group-wise association between multiple rare (and common variants in a gene region and a disease. All tests depend on the numbers of transmitted mutant alleles from parents to their diseased children across variants and hence they are robust to the effect of population stratification. We use extensive simulation studies to compare the performance of four competing tests: the largest single-variant transmission disequilibrium test (TDT, multivariable test, combined TDT, and a likelihood ratio test based on a random-effects model. We find that the likelihood ratio test is most powerful in a wide range of settings and there is no negative impact to its power performance when common variants are also included in the analysis. If deleterious and protective variants are simultaneously analyzed, the likelihood ratio test was generally insensitive to the effect directionality, unless the effects are extremely inconsistent in one direction.

  20. Experimental study for sensorless broken bar detection in induction motors

    International Nuclear Information System (INIS)

    Calis, Hakan; Cakir, Abduelkadir

    2008-01-01

    This study presents experimental results of sensorless broken bar detection in induction motors based on fluctuations of the stator current zero crossing instants before actual breakdown occurs. These fluctuations are sensed by a microcontroller (μC), and transferred to a computer for monitoring the amplitude changes on specific frequency components using fast Fourier transformation algorithms. The motor current signal is also monitored for verification purposes. The main reasons of rotor faults are broken bars, end ring faults and bearing faults. Most recent efforts are focusing on current spectrum analysis, as the current signal is easily accessible for all induction motors. Instead of sampling motor current with a high resolution analog to digital converter, zero crossing instants are recorded as the waveforms cross zero. Fluctuations in the intervals between successive zero crossings of the three phase current waveforms are analyzed in the frequency domain. Broken bars and end ring breakages, supply unbalances, rotor eccentricities and shaft misalignment faults are distinguished by monitoring amplitude changes of the 2sf, f r , and 2f spectral components, where s is the motor slip, f is supply frequency and f r is rotor speed. Appearance of only the 2sf component in zero crossing times (ZCT) of the signal spectrum implies rotor faults. The 2f component occurs only when supply is unbalanced or in the case of stator winding faults. Separation of these two faults is implemented by monitoring both components. In addition, when there is additional rotor eccentricity due to bearing deterioration or shaft misalignment, it is also necessary to monitor the f r fault signature component to distinguish mixed faults. It may be necessary to include additional signals such as motor vibration or temperature to extend the reliability of the fault detection system for critical machines

  1. Experimental studies of the acoustic detection of particle showers

    International Nuclear Information System (INIS)

    Sulak, L.R.; Bowen, T.; Pifer, B.

    1977-01-01

    The scale and characteristics required of a detector that will measure ultrahigh-energy cosmic ray neutrino interactions have been studied in detail. Results obtained to date in observing acoustic signals from hadronic showers both at Brookhaven National Laboratory (BNL) and Harvard University are reported. It is suggested that ultrasonic particle detection is possible, currently down to the level of 10 14 eV. This simple, inexpensive technique may be ideal for observing the secondaries produced in a massive (10 9 ton) neutrino detector. Three experimental tests were performed to determine if showers produce detectable sonic signals as recently predicted. One at the 200-MeV linac at BNL used heavily ionizing protons stopping in water (range = 30 cm) with total energy depositions between 10 19 and 20 21 eV and deposition times ranging from 3 μs to 200 μs. The diameter of the beam was fixed at 6 cm (a characteristic time of 30 μs). A similar test was done at the 160-MeV cyclotron at Harvard, where the energy deposition could be decreased to 10 15 eV. A third test was done with minimum ionizing protons from the 28-GeV fast extracted beam at BNL. As in the BNL linac test, the beam could not be tuned below energy depositions of 10 19 . Typically 3 x 10 11 protons traversed 30 cm of water during a deposition time of 2 μs with a beam diameter variable between 5 and 20 cm

  2. Delayed neutron detection in canning burst detection studies (1961); Etude sur la detection des neutrons differes en vue de la detection des ruptures de gaines (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Perlini, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    This paper describes a theoretical and experimental study on the detection of neutrons present in the primary cooling circuit of a reactor cooled by heavy or light water, with a view to the installation of a canning burst detection unit. The concentration of background neutrons is first calculated, taking into account the neutrons from nitrogen 17 decay, and the photoneutrons produced by the decay of nitrogen 16 and sodium 24. The emission of delayed fission neutrons, originating at a given crack in the canning, has been estimated. Using the D{sub 2}O circuit of the pile EL-3, three units have been developed by means of which the following three types of detector may be compared: 1) BF{sub 3} proportional counter 2) Boron scintillator 3) Fission chamber Under the present experimental conditions the BF{sub 3} counter gave the best results. The influence on these detectors of the {gamma} flux, which in certain cases reaches 200 R/h, is analysed. Finally a calibration is carried out with an experimental crack of 30 mm{sup 2} of uranium exposed to a flux of 5.8 x 10{sup 13} n.cm{sup -2}.s{sup -1}. The sensitivity obtained with the BF{sub 3} counter during this test is 2 counts/s per mm{sup 2} of exposed uranium. (author) [French] Le present rapport est une etude theorique et experimentale sur la detection des neutrons presents dans le circuit primaire de refroidissement d'un reacteur refrigere par l'eau lourde ou l'eau legere, en vue d'une installation de detection de ruptures de gaines. On fait d'abord un calcul sur la concentration des neutrons de bruit de fond en tenant compte: des neutrons de decroissance de l'azote 17 et des photoneutrons produits par les decroissances de l'azote 16 et du sodium 24. L'emission des neutrons differes de fission, qui ont pour origine une fissure de gaine donnee, a ete evaluee. Utilisant le circuit D{sub 2}O de la pile EL3, trois installations ont ete mises au point permettant de comparer les trois types de detecteurs suivants: 1

  3. A Comparative Study of Data Mining Algorithms for High Detection Rate in Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Nabeela Ashraf

    2018-01-01

    Full Text Available Due to the fast growth and tradition of the internet over the last decades, the network security problems are increasing vigorously. Humans can not handle the speed of processes and the huge amount of data required to handle network anomalies. Therefore, it needs substantial automation in both speed and accuracy. Intrusion Detection System is one of the approaches to recognize illegal access and rare attacks to secure networks. In this proposed paper, Naive Bayes, J48 and Random Forest classifiers are compared to compute the detection rate and accuracy of IDS. For experiments, the KDD_NSL dataset is used.

  4. A study of the laser power online detecting

    Science.gov (United States)

    Zhang, Qiue; Zhang, Rong; Li, Yongzheng

    2008-12-01

    This article introduced a fundamental of new intelligent instruments. It can be used in laser power online detecting. Based in this theory, we have made a new intelligent mini-power meter. The device adopt SPCE061A MPU to control and process the all detected data, Its CPU core is used 16-bits MPU, it is a perfect unit in industry field. It can process complicated digital signals. Its detecting parts adopt high-speed responding and high-sensitive photoelectric dynatron 3DU13 to detecting the beam's output. It respond spectrum is from 0.4 to 1.1µm, can detect any other laser source's online detecting. Which locate in this spectrum range, optical design is made up of 45 degrees high reflect device and dark body scattering structure. The detector receive a little scatter light, use on-chip ADC to sampling the detector's output. By subsection, insert value linearity, proportion calculate to beam's output powers. And then real-time to displaying by LCD. It can communicate to PC by RS232. By communicate to upper instrument and others, the users can use detected data to achieve laser power's closed-loop control, to control laser source's real time output correctly and calibrating by itself. This mini-power meter need use standard power meter to calibrate in installing, after this process, the device can detect laser power's output from 1 to 200 watts correctly. It error is less than 5 percent.

  5. Additive Manufacturing Materials Study for Gaseous Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Steer, C.A.; Durose, A.; Boakes, J. [AWE Aldermaston, Reading, Berkshire, RG7 4PR (United Kingdom)

    2015-07-01

    Additive manufacturing (AM) techniques may lead to improvements in many areas of radiation detector construction; notably the rapid manufacturing time allows for a reduced time between prototype iterations. The additive nature of the technique results in a granular microstructure which may be permeable to ingress by atmospheric gases and make it unsuitable for gaseous radiation detector development. In this study we consider the application of AM to the construction of enclosures and frames for wire-based gaseous radiation tracking detectors. We have focussed on oxygen impurity ingress as a measure of the permeability of the enclosure, and the gas charging and discharging curves of several simplistic enclosure shapes are reported. A prototype wire-frame is also presented to examine structural strength and positional accuracy of an AM produced frame. We lastly discuss the implications of this study for AM based radiation detection technology as a diagnostic tool for incident response scenarios, such as the interrogation of a suspect radiation-emitting package. (authors)

  6. Mobility Spectrometer Studies on Hydrazine and Ammonia Detection

    Science.gov (United States)

    Niu, William; Eiceman, Gary; Szumlas, Andrew; Lewis, John

    2011-01-01

    An airborne vapor analyzer for detecting sub- to low- parts-per-million (ppm) hydrazine in the presence of higher concentration levels of ammonia has been under development for the Orion program. The detector is based on ambient pressure ionization and ion mobility characterization. The detector encompasses: 1) a membrane inlet to exclude particulate and aerosols from the analyzer inlet; 2) a method to separate hydrazine from ammonia which would otherwise lead to loss of calibration and quantitative accuracy for the hydrazine determination; and 3) response and quantitative determinations for both hydrazine and ammonia. Laboratory studies were made to explore some of these features including mobility measurements mindful of power, size, and weight issues. The study recommended the use of a mobility spectrometer of traditional design with a reagent gas and equipped with an inlet transfer line of bonded phase fused silica tube. The inlet transfer line provided gas phase separation of neutrals of ammonia from hydrazine at 50 C simplifying significantly the ionization chemistry that underlies response in a mobility spectrometer. Performance of the analyzer was acceptable between ranges of 30 to 80 C for both the pre-fractionation column and the drift tube. An inlet comprised of a combined membrane with valve-less injector allowed high speed quantitative determination of ammonia and hydrazine without cross reactivity from common metabolites such as alcohols, esters, and aldehydes. Preliminary test results and some of the design features are discussed.

  7. Additive Manufacturing Materials Study for Gaseous Radiation Detection

    International Nuclear Information System (INIS)

    Steer, C.A.; Durose, A.; Boakes, J.

    2015-01-01

    Additive manufacturing (AM) techniques may lead to improvements in many areas of radiation detector construction; notably the rapid manufacturing time allows for a reduced time between prototype iterations. The additive nature of the technique results in a granular microstructure which may be permeable to ingress by atmospheric gases and make it unsuitable for gaseous radiation detector development. In this study we consider the application of AM to the construction of enclosures and frames for wire-based gaseous radiation tracking detectors. We have focussed on oxygen impurity ingress as a measure of the permeability of the enclosure, and the gas charging and discharging curves of several simplistic enclosure shapes are reported. A prototype wire-frame is also presented to examine structural strength and positional accuracy of an AM produced frame. We lastly discuss the implications of this study for AM based radiation detection technology as a diagnostic tool for incident response scenarios, such as the interrogation of a suspect radiation-emitting package. (authors)

  8. The detection and study of pre-planetary disks

    Science.gov (United States)

    Sargent, A. I.; Beckwith, S. V. W.

    1994-01-01

    A variety of evidence suggests that at least 50% of low-mass stars are surrounded by disks of the gas and dust similar to the nebula that surrounded the Sun before the formation of the planets. The properties of these disks may bear strongly on the way in which planetary systems form and evolve. As a result of major instrumental developments over the last decade, it is now possible to detect and study the circumstellar environments of the very young, solar-type stars in some detail, and to compare the results with theoretical models of the early solar system. For example, millimeter-wave aperture synthesis imaging provides a direct means of studying in detail the morphology, temperature and density distributions, velocity field and chemical constituents in the outer disks, while high resolution, near infrared spectroscopy probes the inner, warmer parts; the emergence of gaps in the disks, possibly reflecting the formation of planets, may be reflected in the variation of their dust continuum emission with wavelength. We review progress to date and discuss likely directions for future research.

  9. Detection of intracavitary masses on gated scans: a phantom study

    International Nuclear Information System (INIS)

    Cho, B.; Yasuda, Tsunehiro; Moore, R.H.; Boucher, C.A.; Strauss, H.W.

    1987-01-01

    A series of 1.5, 2.0 and 3.0 cm diameter paraffin balls were placed on a 3 cm tether within a simulated left ventricular balloon phantom to determine the maximal balloon volume that permitted identification of the lesion. When images were recorded with the phantom stationary, the lesions could be detected at 100, 280 and 360 ml volumes, respectively. When the phantom was set in motion with a fixed 80 ml stroke volume, the lesions were detected at 120, 320 and 360 ml, respectively. These findings suggest that gating does not decrease lesion detection even when the lesion is freely mobile, and a 1.5 cm lesion would be difficult to detect in an enlarged ventricle, but 2 and 3 cm lesions could be detected even in the presence of moderate ventricular enlargement. (author)

  10. Imaging studies and biomarkers to detect clinically meaningful vesicoureteral reflux

    Directory of Open Access Journals (Sweden)

    Michaella Maloney Prasad

    2017-06-01

    Full Text Available The work-up of a febrile urinary tract infection is generally performed to detect vesicoureteral reflux (VUR and its possible complications. The imaging modalities most commonly used for this purpose are renal-bladder ultrasound, voiding cystourethrogram and dimercapto-succinic acid scan. These studies each contribute valuable information, but carry individual benefits and limitations that may impact their efficacy. Biochemical markers are not commonly used in pediatric urology to diagnose or differentiate high-risk disease, but this is the emerging frontier, which will hopefully change our approach to VUR in the future. As it becomes more apparent that there is tremendous clinical variation within grades of VUR, the need to distinguish clinically significant from insignificant disease grows. The unfortunate truth about VUR is that recommendations for treatment may be inconsistent. Nuances in clinical decision-making will always exist, but opinions for medical versus surgical intervention should be more standardized, based on risk of injury to the kidney.

  11. Development and evaluation of a boat-mounted RFID antenna for monitoring freshwater mussels

    Science.gov (United States)

    Fischer, Jesse R.; Neebling, Travis E.; Quist, Michael C.

    2012-01-01

    Development of radio frequency identification (RFID) technology and passive integrated transponder (PIT) tags has substantially increased the ability of researchers and managers to monitor populations of aquatic organisms. However, use of transportable RFID antenna systems (i.e., backpack-mounted) is currently limited to wadeable aquatic environments (RFID antenna to detect individually PIT-tagged benthic aquatic organisms (mussels). We evaluated the effects of tag orientation on detection distances in water with a 32-mm half-duplex PIT tag. Detection distances up to 50 cm from the antenna coils were obtained, but detection distance was dependent on tag orientation. We also evaluated detection distance of PIT tags beneath the sediment to simulate detection of burrowing mussels with 23- and 32-mm tags. In sand substrate, the maximum detection distance varied from 3.5 cm and 4.5 cm (vertical tag orientation) to 24.7 cm and 39.4 cm (45° tag orientation) for the 23- and 32-mm PIT tags, respectively. Our results suggest a 1.4-m total detection width for tagged mussels on the substrate surface by the boat-mounted antenna system regardless of tag orientation. However, burrowed mussels may require multiple passes to increase detection that would be influenced by depth, tag orientation, and tag size. Construction of the boat-mounted antenna was relatively low in cost (<500 USD) and had several advantages (less labor and time intensive, increased safety) over traditional mussel sampling techniques (diving, snorkeling) in nonwadeable habitats.

  12. Study of detection probability from lesion by scintiscanning

    International Nuclear Information System (INIS)

    Silva, D.C. da; Dias-Neto, A.L.

    1992-01-01

    The importance of work with the information density parameter in scintiscanning is described, fixing the minimum values of information density, above of which the existent injuries are not detected, allowing also the reproducibility of the examination. (C.G.C.)

  13. Comparative study of angio genesis radiopharmaceuticals for melanoma detection

    International Nuclear Information System (INIS)

    Oliveira, Erica Aparecida de

    2011-01-01

    Early diagnosis and treatment of melanoma, a cutaneous tumor with a serious prognosis, is extremely important for optimal clinical outcome. Phage display peptide libraries are a useful screening resource for identifying bioactive peptides that interact with cancer targets. The aim of this study was the evaluation of two technetium-99m tracers for angio genesis detection in melanoma model, using cyclic peguilated pentapeptide with RGD and NGR motifs conjugated with bifunctional chelator MAG3. The conjugated peptides (10 μL of a μg/μL solution) were labeled with technetium-99m using a sodium tartrate buffer. Radiochemical evaluation was done by ITLC and confirmed by HPLC. Partition coefficient was determined and internalization assays were performed in two melanoma cells (B16F10 and SKMEL28). Biodistribution evaluation of the tracers was done in healthy animals at different times and also in mice bearing the tumor cells at 120 min post injection. Blocking studies were also conducted by co-injection of cold peptides. The conjugated showed the same profile in many evaluations. They were radiolabeled with high radiochemical purity (>97%). Both were hydrophilic, with preferential renal excretion. Tumor uptake was higher for human melanoma cells than for murinic melanoma cells, specially for 99m Tc-MAG3-PEG 8 -c(RGDyK) (7.85±±2.34 %ID/g) at 120 min post injection. The performance of 99m Tc-MAG 3 -PEG 8 -c(RGDyk) was much better than NGR tracer concerning human melanoma uptake and might be considered in future investigations focusing radiotracers for melanoma diagnosis. (author)

  14. MCNP to study the BF3 detection efficiency

    International Nuclear Information System (INIS)

    Castro, Vinicius A.; Cavalieri, Tassio A.; Siqueira, Paulo T.D.; Fedorenko, Giuliana G.; Coelho, Paulo R.P.; Madi Filho, Tufic

    2011-01-01

    One of the main parameters to monitor on the employment of the Boron Neutron Capture Therapy (BNCT) is the thermal neutron flux. It can be performed by different techniques such as the activation analysis and the detection by a Boron Trifluoride detector (BF 3 ). BF 3 detector is a real time neutron flux detector which retrieves results in real time. It is however necessary to study the efficiency of the BF 3 detectors when they are exposed to fields of different neutron energy spectra. BF 3 is known to have high efficiency for thermal neutrons (with energy up to 0.5 eV) due the presence of 10 B atoms in the detector. However, one must also understand how this detector interacts with other neutron energy ranges (epithermal and fast). This work shows the experiment and a set of associated simulations carried out in order to evaluate the BF 3 detector efficiency dependence on neutron energy spectra. A set of experiments was conducted in which a BF 3 detector was submitted to different mixed fields (field containing gamma rays and neutrons). These fields were generated by the interposition of paraffin layers with distinct thicknesses between the Am-Be source and the BF 3 detector. The BF 3 detector responses were recorded according to the number of paraffin planes used. MCNP simulations were also performed to study the detector responses on such experimental conditions. It has been possible to achieve the intended goal of evaluating the BF 3 detector response to different mixed irradiation fields. (author)

  15. Early complication detection after colorectal surgery (CONDOR): study protocol for a prospective clinical diagnostic study

    NARCIS (Netherlands)

    Kornmann, Verena; van Ramshorst, Bert; van Dieren, Susan; van Geloven, Nanette; Boermeester, Marja; Boerma, Djamila

    2016-01-01

    Anastomotic leakage is one of the most feared complications following colorectal surgery with a high morbidity and mortality rate. Multiple risk factors have been identified, but leakage still occurs. Early detection is crucial in order to reduce morbidity and mortality. The aim of this study is to

  16. Studies on defect detectability in banded stainless steel tubes

    International Nuclear Information System (INIS)

    Shyamsunder, M.T.; Rao, B.P.C.; Babu Rao, C.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    During inspection of one batch of stainless steel cladding tubes, a few of the tubes gave rise to continuous large amplitude indications throughout the length of the tube. It was observed that the presence of any defects in such tubes would be impossible to detect, due to the poor signal-to-noise ratio. Detailed investigations regarding the surface profile of the tubes were carried out using a novel technique called the projected interferometry method revealed periodic diametral variations and the same were further confirmed by cross sectional profiling. The feasibility of detecting defects in such banded tubes, using eddy current testing were carried out on tubes with artificial defects. This paper discusses the use of three different eddy current methods and their relative performances for inspection. The specific advantages of the phased array eddy current testing method in unambiguous defect detection in situations similar to the one encountered during the present investigations are also discussed. (author)

  17. Subepidermal moisture detection of heel pressure injury: The pressure ulcer detection study outcomes.

    Science.gov (United States)

    Bates-Jensen, Barbara M; McCreath, Heather E; Nakagami, Gojiro; Patlan, Anabel

    2018-04-01

    We examined subepidermal moisture (SEM) and visual skin assessment of heel pressure injury (PrI) among 417 nursing home residents in 19 facilities over 16 weeks. Participants were older (mean age 77 years), 58% were female, over half were ethnic minorities (29% African American, 12% Asian American, 21% Hispanic), and at risk for PrI (mean Braden Scale Risk score = 15.6). Blinded concurrent visual assessments and SEM measurements were obtained at heels weekly. Visual skin damage was categorised as normal, erythema, stage 1 PrI, deep tissue injury (DTI) or stage 2 or greater PrI. PrI incidence was 76%. Off-loading occurred with pillows (76% of residents) rather than heel boots (21%) and often for those with DTI (91%). Subepidermal moisture was measured with a device where higher readings indicate greater moisture (range: 0-70 tissue dielectric constant), with normal skin values significantly different from values in the presence of skin damage. Subepidermal moisture was associated with concurrent damage and damage 1 week later in generalised multinomial logistic models adjusting for age, diabetes and function. Subepidermal moisture detected DTI and differentiated those that resolved, remained and deteriorated over 16 weeks. Subepidermal moisture may be an objective method for detecting PrI. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  18. A study on obstacle detection method of the frontal view using a camera on highway

    Science.gov (United States)

    Nguyen, Van-Quang; Park, Jeonghyeon; Seo, Changjun; Kim, Heungseob; Boo, Kwangsuck

    2018-03-01

    In this work, we introduce an approach to detect vehicles for driver assistance, or warning system. For driver assistance system, it must detect both lanes (left and right side lane), and discover vehicles ahead of the test vehicle. Therefore, in this study, we use a camera, it is installed on the windscreen of the test vehicle. Images from the camera are used to detect three lanes, and detect multiple vehicles. In lane detection, line detection and vanishing point estimation are used. For the vehicle detection, we combine the horizontal and vertical edge detection, the horizontal edge is used to detect the vehicle candidates, and then the vertical edge detection is used to verify the vehicle candidates. The proposed algorithm works with of 480 × 640 image frame resolution. The system was tested on the highway in Korea.

  19. Monitoring the Migrations of Wild Snake River Spring/Summer Chinook Salmon Smolts, 2002-2003 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Achord, Stephen; McNatt, Regan A.; Hockersmith, Eric E. (National Marine Fisheries Service, Northwest Fisheries Science Center, Fish Ecology Division, Seattle, WA)

    2004-04-01

    Prior to 1992, decisions on dam operations and use of stored water relied on recoveries of branded hatchery fish, index counts at traps and dams, and flow patterns at the dams. The advent of PIT-tag technology provided the opportunity to precisely track the smolt migrations of many wild stocks as they pass through the hydroelectric complex and other monitoring sites on their way to the ocean. With the availability of the PIT tag, a more complete approach to these decisions was undertaken starting in 1992 with the addition of PIT-tag detections of several wild spring and summer chinook salmon stocks at Lower Granite Dam. Using data from these detections, we initiated development of a database on wild fish, addressing several goals of the Columbia River Basin Fish and Wildlife Program of the Pacific Northwest Electric Power Planning Council and Conservation Act (NPPC 1980). Section 304(d) of the program states, ''The monitoring program will provide information on the migrational characteristics of the various stocks of salmon and steelhead within the Columbia Basin.'' Further, Section 201(b) urges conservation of genetic diversity, which will be possible only if wild stocks are preserved. Section 5.9A.1 of the 1994 Fish and Wildlife Program states that field monitoring of smolt movement will be used to determine the best timing for water storage releases and Section 5.8A.8 states that continued research is needed on survival of juvenile wild fish before they reach the first dam with special attention to water quantity, quality, and several other factors. The goals of this ongoing study are as follows (1) Characterize the migration timing and estimate parr-to-smolt survival of different stocks of wild Snake River spring/summer chinook salmon smolts at Lower Granite Dam. (2) Determine whether consistent migration patterns are apparent. (3) Determine what environmental factors influence these patterns. (4) Characterize the migrational behavior and

  20. Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt

    Science.gov (United States)

    Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong

    2017-07-01

    Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.

  1. Study of cosmic ray nuclei detection by an image calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Casolino, M.; Sparvoli, R.; Morselli, A.; Picozza, P. [Rome Univ. `Tor Vergata` (Italy)]|[INFN, Sezione Univ. `Tor Vergata` Rome (Italy); Ozerov, Yu.V.; Zemskov, V.M.; Zverev, V.G.; Galper, A.M. [Moscow Engineering Physics Institute, Moscow (Russian Federation); Carlson, P. [Royal Institute of Technology, Stockholm (Sweden); Fuglesang, C. [ESA-EAC, Cologne (Germany)

    1995-09-01

    It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

  2. Molecular approaches to detect and study the organisms causing ...

    African Journals Online (AJOL)

    This review will summarise the molecular approaches used to detect and analyse the genomes of Babesia bovis, B. bigemina and Anaplasma marginale which cause bovine babesiosis and anaplasmosis. These tick borne diseases are widely distributed in Africa, Asia, Australia, and Central and South America and for ...

  3. Study of the casting speedy radiation-detection system

    International Nuclear Information System (INIS)

    Tan Xiaochun; Huang Junqing; Shi Xianbei; Zhao Gang; Wang Liping

    2001-01-01

    The paper introduces the design of the launching speedy radiation-detection system. It consists of launcher, semiconductor detector, microprocessor and communicator. It can give the intensity, position, time of radiation. The paper discusses the function, composition, principle, speciality and technical problem of this system

  4. NIR spectrometry for counterfeit drug detection - A feasibility study

    DEFF Research Database (Denmark)

    Rodionova, O.Y.; Houmøller, Lars P.; Pomerantsev, A.L.

    2005-01-01

    for mathematical data processing for false drugs detection is demonstrated. Also, multivariate hyperspectral image analysis is applied providing additional diagnostic information. Hyperspectral imaging is becoming a useful diagnostic tool for identifying non-homogeneous spatial regions of drug formulation. Two...... types of drugs are used to demonstrate the applicability of these approaches....

  5. Rapid detection of exotic Lymantriids and Scolytids pilot study

    Science.gov (United States)

    Mary Ellen Dix

    2003-01-01

    Exotic invasive species, inadvertently introduced into North America through importation and travel, are threatening the integrity of North American forest ecosystems. The National Invasive Species Council in their 2001 Strategic Plan identified a collaborative program for early detection, diagnosis and response to high-risk, exotic, invasive insects, pathogens and...

  6. Study on high power ultraviolet laser oil detection system

    Science.gov (United States)

    Jin, Qi; Cui, Zihao; Bi, Zongjie; Zhang, Yanchao; Tian, Zhaoshuo; Fu, Shiyou

    2018-03-01

    Laser Induce Fluorescence (LIF) is a widely used new telemetry technology. It obtains information about oil spill and oil film thickness by analyzing the characteristics of stimulated fluorescence and has an important application in the field of rapid analysis of water composition. A set of LIF detection system for marine oil pollution is designed in this paper, which uses 355nm high-energy pulsed laser as the excitation light source. A high-sensitivity image intensifier is used in the detector. The upper machine sends a digital signal through a serial port to achieve nanoseconds range-gated width control for image intensifier. The target fluorescence spectrum image is displayed on the image intensifier by adjusting the delay time and the width of the pulse signal. The spectral image is coupled to CCD by lens imaging to achieve spectral display and data analysis function by computer. The system is used to detect the surface of the floating oil film in the distance of 25m to obtain the fluorescence spectra of different oil products respectively. The fluorescence spectra of oil products are obvious. The experimental results show that the system can realize high-precision long-range fluorescence detection and reflect the fluorescence characteristics of the target accurately, with broad application prospects in marine oil pollution identification and oil film thickness detection.

  7. Computed tomography with energy-resolved detection: a feasibility study

    Science.gov (United States)

    Shikhaliev, Polad M.

    2008-03-01

    The feasibility of computed tomography (CT) with energy-resolved x-ray detection has been investigated. A breast CT design with multi slit multi slice (MSMS) data acquisition was used for this study. The MSMS CT includes linear arrays of photon counting detectors separated by gaps. This CT configuration allows for efficient scatter rejection and 3D data acquisition. The energy-resolved CT images were simulated using a digital breast phantom and the design parameters of the proposed MSMS CT. The phantom had 14 cm diameter and 50/50 adipose/glandular composition, and included carcinoma, adipose, blood, iodine and CaCO3 as contrast elements. The x-ray technique was 90 kVp tube voltage with 660 mR skin exposure. Photon counting, charge (energy) integrating and photon energy weighting CT images were generated. The contrast-to-noise (CNR) improvement with photon energy weighting was quantified. The dual energy subtracted images of CaCO3 and iodine were generated using a single CT scan at a fixed x-ray tube voltage. The x-ray spectrum was electronically split into low- and high-energy parts by a photon counting detector. The CNR of the energy weighting CT images of carcinoma, blood, adipose, iodine, and CaCO3 was higher by a factor of 1.16, 1.20, 1.21, 1.36 and 1.35, respectively, as compared to CT with a conventional charge (energy) integrating detector. Photon energy weighting was applied to CT projections prior to dual energy subtraction and reconstruction. Photon energy weighting improved the CNR in dual energy subtracted CT images of CaCO3 and iodine by a factor of 1.35 and 1.33, respectively. The combination of CNR improvements due to scatter rejection and energy weighting was in the range of 1.71-2 depending on the type of the contrast element. The tilted angle CZT detector was considered as the detector of choice. Experiments were performed to test the effect of the tilting angle on the energy spectrum. Using the CZT detector with 20° tilting angle decreased the

  8. The detection of hepatocellular carcinoma (HCC) from patients' breath using canine scent detection: a proof-of-concept study.

    Science.gov (United States)

    Kitiyakara, Taya; Redmond, Susan; Unwanatham, Nattawut; Rattanasiri, Sasivimol; Thakkinstian, Amarin; Tangtawee, Pongsatorn; Mingphruedhi, Somkit; Sobhonslidsuk, Abhasnee; Intaraprasong, Pongphob; Kositchaiwat, Chomsri

    2017-09-13

    Patients with hepatocellular carcinoma (HCC) have poor outcomes as a result of late detection of the disease. We investigated the possibility of using smell detection by dogs for detecting HCC from the breath of patients. Patients whose diagnosis of HCC was confirmed histologically or radiologically according to the American Association for the Study of Liver Diseases criteria had breaths collected using face masks and transported to the study test site. The numbering of the HCC samples was sent in a sealed envelope to blind the dog trainer during testing but allow for correct rewarding of the dog afterwards. One golden retriever was trained to detect HCC with positive feedback using known samples of HCC and healthy controls in a step-wise manner. The controls were selected from hospital staff and relatives of patients who were not involved in the study. They were questioned about the risks of their disease before selection. When the trainer was confident that the dog could recognize the HCC scent, blind testing was performed using 1 HCC : 3 healthy controls per test run. Once the dog signaled on a specimen, it was given a reward. The correct-detection rate was compared to the theoretical detection rate expected based on chance of 25% using the statistical one-sample test of proportions. Thirty-seven HCC patients were tested. The patients had a mean age of 58 years and 21/37 were male. Seventeen patients had hepatitis B and 14 patients had hepatitis C. Twenty-six patients had one HCC lesion; four patients had two lesions in the liver, whilst seven had many lesions. The number of patients in the very early, early, intermediate, advanced, and terminal stages of the Barcelona Clinic Liver Cancer classification was 5, 9, 21, 1, and 1, respectively. The dog detected correctly in 29 runs. The sensitivity for canine detection was 78% (95% CI: 62%-90%). Compared to the 25% correct indication expected based on chance, this was statistically significant (p canine olfaction

  9. Study on UPF Harmonic Current Detection Method Based on DSP

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H J [Northwestern Polytechnical University, Xi' an 710072 (China); Pang, Y F [Xi' an University of Technology, Xi' an 710048 (China); Qiu, Z M [Xi' an University of Technology, Xi' an 710048 (China); Chen, M [Northwestern Polytechnical University, Xi' an 710072 (China)

    2006-10-15

    Unity power factor (UPF) harmonic current detection method applied to active power filter (APF) is presented in this paper. The intention of this method is to make nonlinear loads and active power filter in parallel to be an equivalent resistance. So after compensation, source current is sinusoidal, and has the same shape of source voltage. Meanwhile, there is no harmonic in source current, and the power factor becomes one. The mathematic model of proposed method and the optimum project for equivalent low pass filter in measurement are presented. Finally, the proposed detection method applied to a shunt active power filter experimental prototype based on DSP TMS320F2812 is developed. Simulation and experiment results indicate the method is simple and easy to implement, and can obtain the real-time calculation of harmonic current exactly.

  10. Comparative study of thermoluminescence detection methods for irradiated spices

    International Nuclear Information System (INIS)

    Kawamura, Y.; Kojima, K.; Sugita, T.; Yamada, T.; Saito, Y.

    1995-01-01

    The thermoluminescence (TL) detection methods for irradiated spices were compared using spice samples obtained on the Japanese market, irradiated at doses of 1, 5, 10 and 30 kGy and stored for 1 year before analysis. The TL intensities of irradiated spices were stable for 1 year after irradiation. Measurement with whole samples failed to identify irradiated samples. Minerals were separated from spices in sodium tungstate saturated solution and/or sodium polytungstate solution. The TL intensity of minerals which had undergone irradiation was significantly increased for all samples. However, the ranges of TL intensity of irradiated and unirradiated samples overlapped. Clear discrimination has been obtained between the TL ratios of irradiated and unirradiated spices by using normalized measurement with reirradiation. The detection limit in terms of irradiation dose is 1 kGy even in a sample that has been irradiated 1 year prior to analysis. Normalization is the best technique currently available for thermoluminescence analysis to identify irradiated spices

  11. Study on loss detection algorithms using tank-monitoring data

    International Nuclear Information System (INIS)

    Suzuki, Mitsutoshi; Hori, Masato; Nagaoka, Shinichi; Kimura, Takashi

    2009-01-01

    An application of solution monitoring to material balance evaluation has been investigated with actual data from the Solution Monitoring Management System (SMMS) in the Tokai Reprocessing Plant (TRP). Loss detection capabilities of the proposed multivariate statistical methods are examined numerically for a simulated loss corresponding to parameters of a significant quantity in the wait mode. Multiscale statistical analysis as well as multivariate cumulative sum analysis are successfully used to demonstrate the protracted-loss detection. Because the actual tank data is composed of records in both the wait and transfer modes, the tank-to-tank transferring data is extracted from the sequence of monitoring data, and the error model effectiveness is evaluated in comparison with calculations. Although the data taken from the SMMS does not describe the entire solution process, an extended application of solution monitoring to the nuclear material accounting is advanced using the plant data, and future research subjects are described. (author)

  12. Microbiological studies for the detection of irradiated food

    International Nuclear Information System (INIS)

    Abd-Elbary, N.A.

    2001-01-01

    the exposure of food to ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests, and to extend shelf life, thereby contributing to a safer and more plentiful food supply. to ensure free consumer choice, irradiated food will be labeled as such, and to enforce labeling, analytical methods to detect the irradiation treatment in the food product itself are desirable, in particular, there is a need for simple and rapid screening methods for the control of irradiated food.this investigation has been carried out in an effect to design reliable methods for detecting whether or not a food has been irradiated . attempts have been made to apply microbiological and biological form measurement

  13. Leak detection, monitoring, and mitigation technology trade study update

    International Nuclear Information System (INIS)

    HERTZEL, J.S.

    1998-01-01

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful

  14. Accounting for imperfect detection in Hill numbers for biodiversity studies

    Science.gov (United States)

    Broms, Kristin M.; Hooten, Mevin B.; Fitzpatrick, Ryan M.

    2015-01-01

    Hill numbers unify biodiversity metrics by combining several into one expression. For example, species richness, Shannon's diversity index and the Gini–Simpson index are a few of the most used diversity measures, and they can be expressed as Hill numbers. Traditionally, Hill numbers have been calculated from relative abundance data, but the expression has been modified to use incidence data as well. We demonstrate an approach for estimating Hill numbers using an occupancy modelling framework that accounts for imperfect detection.

  15. Studying Fake News via Network Analysis: Detection and Mitigation

    OpenAIRE

    Shu, Kai; Bernard, H. Russell; Liu, Huan

    2018-01-01

    Social media for news consumption is becoming increasingly popular due to its easy access, fast dissemination, and low cost. However, social media also enable the wide propagation of "fake news", i.e., news with intentionally false information. Fake news on social media poses significant negative societal effects, and also presents unique challenges. To tackle the challenges, many existing works exploit various features, from a network perspective, to detect and mitigate fake news. In essence...

  16. Leak detection, monitoring, and mitigation technology trade study update

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document is a revision and update to the initial report that describes various leak detection, monitoring, and mitigation (LDMM) technologies that can be used to support the retrieval of waste from the single-shell tanks (SST) at the Hanford Site. This revision focuses on the improvements in the technical performance of previously identified and useful technologies, and it introduces new technologies that might prove to be useful.

  17. Feasibility Study On Missile Launch Detection And Trajectory Tracking

    Science.gov (United States)

    2016-09-01

    Feature (SURF) detection, and Kalman filtering are frequently used for object tracking. These methods have been applied frequently on video records...missile by processing the thermal imagery from the thermal-imaging sensor, which captures the temperature gradient of the surroundings within its field of...view. As the missile’s propulsion motor emits gases at high temperature to generate the thrust required for its flight, the heat 2 signature of

  18. Multimodal UAV detection: study of various intrusion scenarios

    Science.gov (United States)

    Hengy, Sebastien; Laurenzis, Martin; Schertzer, Stéphane; Hommes, Alexander; Kloeppel, Franck; Shoykhetbrod, Alex; Geibig, Thomas; Johannes, Winfried; Rassy, Oussama; Christnacher, Frank

    2017-10-01

    Small unmanned aerial vehicles (UAVs) are becoming increasingly popular and affordable the last years for professional and private consumer market, with varied capacities and performances. Recent events showed that illicit or hostile uses constitute an emergent, quickly evolutionary threat. Recent developments in UAV technologies tend to bring autonomous, highly agile and capable unmanned aerial vehicles to the market. These UAVs can be used for spying operations as well as for transporting illicit or hazardous material (smuggling, flying improvised explosive devices). The scenario of interest concerns the protection of sensitive zones against the potential threat constituted by small drones. In the recent past, field trials were carried out to investigate the detection and tracking of multiple UAV flying at low altitude. Here, we present results which were achieved using a heterogeneous sensor network consisting of acoustic antennas, small FMCW RADAR systems and optical sensors. While acoustics and RADAR was applied to monitor a wide azimuthal area (360°), optical sensors were used for sequentially identification. The localization results have been compared to the ground truth data to estimate the efficiency of each detection system. Seven-microphone acoustic arrays allow single source localization. The mean azimuth and elevation estimation error has been measured equal to 1.5 and -2.5 degrees respectively. The FMCW radar allows tracking of multiple UAVs by estimating their range, azimuth and motion speed. Both technologies can be linked to the electro-optical system for final identification of the detected object.

  19. Disease prevalence and the index of detectability: a survey of studies of lung cancer detection by chest radiography

    Science.gov (United States)

    Kundel, Harold L.

    2000-04-01

    A survey of 12 studies of lung cancer detection with cancer prevalence ranging from 0.9 to 476 cancers per 1000 showed that the unit-slope index of detectability, d', decreased from a high value of 3.9 at low prevalence to 1.4 at high prevalence. A proposed explanation is that the readers are operating on an ROC curve with a slope that is less than unity approximating 0.6. On such a curve, a shift to more stringent criteria that occurs with decreasing prevalence in order to minimize false positives, would result in a increased unity- slope d'.

  20. Colonial waterbird predation on Lost River and Shortnose suckers in the Upper Klamath Basin

    Science.gov (United States)

    Evans, Allen F.; Hewitt, David A.; Payton, Quinn; Cramer, Bradley M.; Collis, Ken; Roby, Daniel D.

    2016-01-01

    We evaluated predation on Lost River Suckers Deltistes luxatus and Shortnose Suckers Chasmistes brevirostris by American white pelicans Pelecanus erythrorhynchos and double-crested cormorants Phalacrocorax auritus nesting at mixed-species colonies in the Upper Klamath Basin of Oregon and California during 2009–2014. Predation was evaluated by recovering (detecting) PIT tags from tagged fish on bird colonies and calculating minimum predation rates, as the percentage of available suckers consumed, adjusted for PIT tag detection probabilities but not deposition probabilities (i.e., probability an egested tag was deposited on- or off-colony). Results indicate that impacts of avian predation varied by sucker species, age-class (adult, juvenile), bird colony location, and year, demonstrating dynamic predator–prey interactions. Tagged suckers ranging in size from 72 to 730 mm were susceptible to cormorant or pelican predation; all but the largest Lost River Suckers were susceptible to bird predation. Minimum predation rate estimates ranged annually from <0.1% to 4.6% of the available PIT-tagged Lost River Suckers and from <0.1% to 4.2% of the available Shortnose Suckers, and predation rates were consistently higher on suckers in Clear Lake Reservoir, California, than on suckers in Upper Klamath Lake, Oregon. There was evidence that bird predation on juvenile suckers (species unknown) in Upper Klamath Lake was higher than on adult suckers in Upper Klamath Lake, where minimum predation rates ranged annually from 5.7% to 8.4% of available juveniles. Results suggest that avian predation is a factor limiting the recovery of populations of Lost River and Shortnose suckers, particularly juvenile suckers in Upper Klamath Lake and adult suckers in Clear Lake Reservoir. Additional research is needed to measure predator-specific PIT tag deposition probabilities (which, based on other published studies, could increase predation rates presented herein by a factor of roughly 2

  1. Early pest detection in soy plantations from hyperspectral measurements: a case study for caterpillar detection

    Science.gov (United States)

    Tailanián, Matías; Castiglioni, Enrique; Musé, Pablo; Fernández Flores, Germán.; Lema, Gabriel; Mastrángelo, Pedro; Almansa, Mónica; Fernández Liñares, Ignacio; Fernández Liñares, Germán.

    2015-10-01

    Soybean producers suffer from caterpillar damage in many areas of the world. Estimated average economic losses are annually 500 million USD in Brazil, Argentina, Paraguay and Uruguay. Designing efficient pest control management using selective and targeted pesticide applications is extremely important both from economic and environmental perspectives. With that in mind, we conducted a research program during the 2013-2014 and 2014-2015 planting seasons in a 4,000 ha soybean farm, seeking to achieve early pest detection. Nowadays pest presence is evaluated using manual, labor-intensive counting methods based on sampling strategies which are time consuming and imprecise. The experiment was conducted as follows. Using manual counting methods as ground-truth, a spectrometer capturing reflectance from 400 to 1100 nm was used to measure the reflectance of soy plants. A first conclusion, resulting from measuring the spectral response at leaves level, showed that stress was a property of plants since different leaves with different levels of damage yielded the same spectral response. Then, to assess the applicability of unsupervised classification of plants as healthy, biotic-stressed or abiotic-stressed, feature extraction and selection from leaves spectral signatures, combined with a Supported Vector Machine classifier was designed. Optimization of SVM parameters using grid search with cross-validation, along with classification evaluation by ten-folds cross-validation showed a correct classification rate of 95%, consistently on both seasons. Controlled experiments using cages with different numbers of caterpillars--including caterpillar-free plants--were also conducted to evaluate consistency in trends of the spectral response as well as the extracted features.

  2. Long-term follow-up of the TIPS early detection in psychosis study

    DEFF Research Database (Denmark)

    Simonsen, Erik; Hegelstad, Wenche ten Welden; Larsen, Tor Ketil

    2012-01-01

    ill patients dropping out of the study in the usual-detection area. Except for higher levels of excitative symptoms in the early-detection area, there were no symptom differences between the groups. Early-detection recovery rates were higher largely because of higher employment rates for patients...

  3. Microbeam recoil detection for hydration of minerals studies

    Energy Technology Data Exchange (ETDEWEB)

    Sie, S H; Suter, G F [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.; Chekhmir, A; Green, T H [Macquarie Univ., North Ryde, NSW (Australia)

    1994-12-31

    The glancing angle geometry is chosen to enable application of the elastic recoil detection microanalysis on thick geological samples, for hydrogen content determination. Simultaneous PIXE measurements can be used to eliminate the problem of uncertainties in beam charge collection. The method is applied to determine the hydration characteristics of silicates, produced experimentally at high pressure and temperature simulating the lower crust and upper mantle conditions. Preliminary results show that the technique can be applied readily on a microscopic (<100 {mu}m) scale for determination of H at fraction of atomic percent level. 9 refs., 3 figs.

  4. Microbeam recoil detection for hydration of minerals studies

    Energy Technology Data Exchange (ETDEWEB)

    Sie, S.H.; Suter, G.F. [CSIRO, North Ryde, NSW (Australia). Exploration and Mining Div.; Chekhmir, A.; Green, T.H. [Macquarie Univ., North Ryde, NSW (Australia)

    1993-12-31

    The glancing angle geometry is chosen to enable application of the elastic recoil detection microanalysis on thick geological samples, for hydrogen content determination. Simultaneous PIXE measurements can be used to eliminate the problem of uncertainties in beam charge collection. The method is applied to determine the hydration characteristics of silicates, produced experimentally at high pressure and temperature simulating the lower crust and upper mantle conditions. Preliminary results show that the technique can be applied readily on a microscopic (<100 {mu}m) scale for determination of H at fraction of atomic percent level. 9 refs., 3 figs.

  5. Indirect Detection Analysis: Wino Dark Matter Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Hryczuk, Andrzej [Munich, Tech. U.; Cholis, Ilias [Fermilab; Iengo, Roberto [SISSA, Trieste; Tavakoli, Maryam [IPM, Tehran; Ullio, Piero [INFN, Trieste

    2014-07-15

    We perform a multichannel analysis of the indirect signals for the Wino Dark Matter, including one-loop electroweak and Sommerfeld enhancement corrections. We derive limits from cosmic ray antiprotons and positrons, from continuum galactic and extragalactic diffuse γ-ray spectra, from the absence of γ-ray line features at the galactic center above 500 GeV in energy, from γ-rays toward nearby dwarf spheroidal galaxies and galaxy clusters, and from CMB power-spectra. Additionally, we show the future prospects for neutrino observations toward the inner Galaxy and from antideuteron searches. For each of these indirect detection probes we include and discuss the relevance of the most important astrophysical uncertainties that can impact the strength of the derived limits. We find that the Wino as a dark matter candidate is excluded in the mass range bellow simeq 800 GeV from antiprotons and between 1.8 and 3.5 TeV from the absence of a γ-ray line feature toward the galactic center. Limits from other indirect detection probes confirm the main bulk of the excluded mass ranges.

  6. Physicochemical studies for detection of irradiated dry date fruits

    International Nuclear Information System (INIS)

    Farag, S.E.A.; El-Salhy, F.T.; Nassef, A.E.; El-beltagy, A.E.; Moharram, H.A.

    2005-01-01

    The kinetic of the water absorption properties of a selected varieties from the Egyptian dry date fruits were carried out. Sakoti, shamia bida, sokaria, candela and malkabee varieties were used to get an idea about their water absorption properties. Malkabee variety was selected for irradiation at different doses of 0.5, 1, 2, 3, 4 and 5 KGy. In order to obtain a fast, reliable and easy techniques for detecting irradiated dates, several physico-chemical and ultrastructural properties were elucidated in this investigation. Regarding to water absorption, the statistical analysis of the water absorption data revealed that, the amount of water absorption (g water/g dry solid) was decreased with increasing the irradiation doses. This phenomena was confirmed when SEM technique was applied, since irradiation caused shrinkage and reduction in the inner cells. The colour indices were measured by colour analyzer (hunter colorimeter). An inversely proportional relationship was observed between the hue angle and the progress in the irradiation dose, In contrast, direct proportional relationship is strongly observed when the color combination a/b was measured. From the chemical analysis point of view, it was observed that irradiation lowered the amount of total sugars by enhanced reducing sugars. From elucidating the physico-chemical properties of the irradiation date palm, it is now possible to establish a stainable fast, reliable and cheap detection method that could be used to distinguish between the irradiated and non-irradiated dry date fruits

  7. Study on detection method of irradiated frozen foods and others

    International Nuclear Information System (INIS)

    Miyahara, Makoto; Toyoda, Masatake; Saito, Yukio

    1997-01-01

    As detection method of the irradiated foods has history of 20 years, it is said that it has no finished chemical method, which is longed to construct as soon as possible. Up-to-date, many kinds of chemical detection methods have been proposed, the o-tyrosine method thought to be hopeful for the irradiated frozen foods among them was selected to investigate. In this method, phenyl alanine is oxidized with a radical formed on irradiation to tyrosine. The o-tyrosine out of the formed isomers is analyzed quantitatively. When irradiation γ-ray to foods, it was found that amounts of o-tyrosine increased to reach about 2 or 3 times of original amounts. This result was also found to agree with the result reported at the ADMIT conference. Furthermore, possibility of judgement using this method was also shown because of difference on 2 or 3 times of o-tyrosine amounts between unirradiated and over 5 kGy irradiated foods. (G.K.)

  8. Field and laboratory notes on development of a PIT-tag system for spillways - Research and Development of New Marking and Monitoring Technologies

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project addresses how to expand the current fish-tracking technologies to enable the fisheries community to successfully carry out the actions, research, and...

  9. Spatio-temporal variability in movement, age, and growth of mountain whitefish (Prosopium williamsoni) in a river network based upon PIT tagging and otolith chemistry

    Science.gov (United States)

    Benjamin, Joseph R.; Wetzel, Lisa A.; Martens, Kyle D.; Larsen, Kimberly; Connolly, Patrick J.

    2013-01-01

    Connectivity of river networks and the movements among habitats can be critical for the life history of many fish species, and understanding of the patterns of movement is central to managing populations, communities, and the landscapes they use. We combined passive integrated transponder tagging over 4 years and strontium isotopes in otoliths to demonstrate that 25% of the mountain whitefish (Prosopium williamsoni) sampled moved between the Methow and Columbia rivers, Washington, USA. Seasonal migrations downstream from the Methow River to the Columbia River to overwinter occurred in autumn and upstream movements in the spring. We observed migration was common during the first year of life, with migrants being larger than nonmigrants. However, growth between migrants and nonmigrants was similar. Water temperature was positively related to the proportion of migrants and negatively related to the timing of migration, but neither was related to discharge. The broad spatio-temporal movements we observed suggest mountain whitefish, and likely other nonanadromous fish, require distant habitats and also suggests that management and conservation strategies to keep connectivity of large river networks are imperative.

  10. Revealing hidden covariation detection: evidence for implicit abstraction at study.

    Science.gov (United States)

    Rossnagel, C S

    2001-09-01

    Four experiments in the brain scans paradigm (P. Lewicki, T. Hill, & I. Sasaki, 1989) investigated hidden covariation detection (HCD). In Experiment 1 HCD was found in an implicit- but not in an explicit-instruction group. In Experiment 2 HCD was impaired by nonholistic perception of stimuli but not by divided attention. In Experiment 3 HCD was eliminated by interspersing stimuli that deviated from the critical covariation. In Experiment 4 a transfer procedure was used. HCD was found with dissimilar test stimuli that preserved the covariation but was almost eliminated with similar stimuli that were neutral as to the covariation. Awareness was assessed both by objective and subjective tests in all experiments. Results suggest that HCD is an effect of implicit rule abstraction and that similarity processing plays only a minor role. HCD might be suppressed by intentional search strategies that induce inappropriate aggregation of stimulus information.

  11. An ESR study on the detection of irradiated red lentil

    International Nuclear Information System (INIS)

    Ercan, I.; Eken, M.

    2001-01-01

    The purpose of this work is to investigate in detail detection of irradiated red lentil. In this way, red lentil powder was analysed by using Bruker EMX ESR spectrometer before and after irradiation between the doses 1-9 kGy at ambient conditions. It was observed that seeds of non-irradiated and irradiated red lentil have a signal having six lines due to Mn''+''2 content. However hull of the red lentil has a single line whose origin is still unknown. Besides, this signal has superposed with the radiation induced one. It was also found that the intensity of radiation induced signal was decreased logarithmically in time, and the change in the intensity was minimal at low doses

  12. Study on visual detection method for wind turbine blade failure

    Science.gov (United States)

    Chen, Jianping; Shen, Zhenteng

    2018-02-01

    Start your abstract here…At present, the non-destructive testing methods of the wind turbine blades has fiber bragg grating, sound emission and vibration detection, but there are all kinds of defects, and the engineering application is difficult. In this regard, three-point slope deviation method, which is a kind of visual inspection method, is proposed for monitoring the running status of wind turbine blade based on the image processing technology. A better blade image can be got through calibration, image splicing, pretreatment and threshold segmentation algorithm. Design of the early warning system to monitor wind turbine blade running condition, recognition rate, stability and impact factors of the method were statistically analysed. The experimental results shown showed that it has highly accurate and good monitoring effect.

  13. Detecting SYN flood attacks via statistical monitoring charts: A comparative study

    KAUST Repository

    Bouyeddou, Benamar

    2017-12-14

    Accurate detection of cyber-attacks plays a central role in safeguarding computer networks and information systems. This paper addresses the problem of detecting SYN flood attacks, which are the most popular Denial of Service (DoS) attacks. Here, we compare the detection capacity of three commonly monitoring charts namely, a Shewhart chart, a Cumulative Sum (CUSUM) control chart and exponentially weighted moving average (EWMA) chart, in detecting SYN flood attacks. The comparison study is conducted using the publicly available benchmark datasets: the 1999 DARPA Intrusion Detection Evaluation Datasets.

  14. Evaluation of 3M molecular detection assay (MDA) Salmonella for the detection of Salmonella in selected foods: collaborative study.

    Science.gov (United States)

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2013-01-01

    The 3M Molecular Detection Assay (MDA) Salmonella is used with the 3M Molecular Detection System for the detection of Salmonella spp. in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Salmonella target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Salmonella method was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG 4.05), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products for raw ground beef and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the POD of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive

  15. Study of TeV range cosmic ray detection with Cherenkov imaging techniques

    International Nuclear Information System (INIS)

    Ansari, R.; Gaillard, J.M.; Parrour, G.

    1992-03-01

    The Monte Carlo study of cosmic ray detection in the TeV energy range has been triggered by the authors' interest in the ARTEMIS (Antimatter Research Through the Earth Moon Ion Spectrometer) proposal. The properties of cosmic ray showers detected by Cherenkov imaging in the visible domain are studied. The detection sensitivity and the accuracy of the reconstruction of the parent particle direction using Cherenkov imaging are discussed. The backbone of the study is the atmospheric shower Monte Carlo generator developed by A.M. Hillas. A comparison between nucleon and photon induced showers of Cherenkov detection is also included. (R.P.) 14 refs., 48 figs., 3 tabs

  16. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    OpenAIRE

    Marie Sylvianne Rabodoarivelo; A Brandao; M C Cergole Novella; A G C. Bombonatte; B Imperiale; N Rakotosamimanana; N Morcillo; V Rasolofo; J C Palomino; A Martin

    2018-01-01

    Background: In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. Methods: This was a multicenter study. Molecular detection of ...

  17. RECENT SUSPECT CASES AND A PILOT DETECTION STUDY

    Directory of Open Access Journals (Sweden)

    KOZUBÍKOVÁ E.

    2006-01-01

    Full Text Available There are only very limited reports about the occurrence of the crayfish plague in Czechia. In recent years, mass mortalities of Astacus spp. with symptoms of possible crayfish plague were noticed in three streams in the country – two in Central Bohemia (1998-9 and one in Silesia (2004. Three dead individuals from the last outbreak were examined for the presence of the crayfish plague pathogen, Aphanomyces astaci, by observation of the presence of hyphae in their cuticle and by a PCR-based diagnostic method. In all three cases the detection was positive. Although causes of mass mortalities from two other localities lack such a direct confirmation, the indirect evidence supports the same conclusion. The main potential vector of A. astaci in Czechia is the American spiny-cheeck crayfish Orconectes limosus, widespread in large rivers of the western part of the country and in various isolated standing waters. Using the same molecular method, we investigated the presence of A. astaci in living O. limosus individuals from six localities (three running and three standing waters. The analysis indicated the presence of the pathogen in animals from five out of six investigated Orconectes populations. One of them is present in the stream where two European Astacus species had gone extinct in 1998-9. Our results suggest that the crayfish plague is still present in Czechia, and that populations of O. limosus represent a reservoir for the crayfish plague pathogen, which directly endangers populations of the native crayfish.

  18. Study of noninvasive detection of latent fingerprints using UV laser

    Science.gov (United States)

    Li, Hong-xia; Cao, Jing; Niu, Jie-qing; Huang, Yun-gang; Mao, Lin-jie; Chen, Jing-rong

    2011-06-01

    Latent fingerprints present a considerable challenge in forensics, and noninvasive procedure that captures a digital image of the latent fingerprints is significant in the field of criminal investigation. The capability of photography technologies using 266nm UV Nd:YAG solid state laser as excitation light source to provide detailed images of unprocessed latent fingerprints is demonstrated. Unprocessed latent fingerprints were developed on various non-absorbent and absorbing substrates. According to the special absorption, reflection, scattering and fluorescence characterization of the various residues in fingerprints (fatty acid ester, protein, and carbosylic acid salts etc) to the UV light to weaken or eliminate the background disturbance and increase the brightness contrast of fingerprints with the background, and using 266nm UV laser as excitation light source, fresh and old latent fingerprints on the surface of four types of non-absorbent objects as magazine cover, glass, back of cellphone, wood desktop paintwork and two types of absorbing objects as manila envelope, notebook paper were noninvasive detected and appeared through reflection photography and fluorescence photography technologies, and the results meet the fingerprint identification requirements in forensic science.

  19. Basic study for tsunami detection with DBF ocean radar

    International Nuclear Information System (INIS)

    Sakai, Shin'ichi; Matsuyama, Masafumi; Okuda, Kouzou; Uehara, Fumihiro

    2015-01-01

    To develop early tsunami warning system utilizing ocean radars, the evaluation of the variety of measuring coverage and data accuracy is indispensable in real oceans. The field observation was carried out at 5 minutes interval with two digital beam forming ocean radars with VHF band from 2012 to 2014 in the sea of Enshu. The high data acquisition areas are found in the extent of 17 km off the coast on a hill site and of 13 km on a low ground site. The measured current by the ocean radar were well correlated with that by the current-meter in the depth of 2 m near the coast with the correlation coefficient of ∼0.6. It is inferred that the main factor of difference in both data sets was due to the presence of wind-driven current through the multi-regression analysis with both current data and wind data. In addition, the order of the temporal current deviations as to the representative time-scale of one hour is about 5 cm/s under the ordinary sea conditions, which suggest that ocean radars could sufficiently detect the current deviation due to grant tsunami. (author)

  20. A Study on Current Status of Detection Technology and Establishment of National Detection Regime against Nuclear/Radiological Terrorism

    International Nuclear Information System (INIS)

    Kwak, Sung Woo; Jang, Sung Soon; Lee, Joung Hoon; Yoo, Ho Sik

    2009-01-01

    Since 1990s, some events - detection of a dirty bomb in a Russian nation park in 1995, 9/11 terrorist attack to WTC in 2001, discovery of Al-Qaeda's experimentation to build a dirty bomb in 2003 etc - have showed that nuclear or radiological terrorism relating to radioactive materials (hereinafter 'radioactive materials' is referred to as 'nuclear material, nuclear spent fuel and radioactive source') is not incredible but serious and credible threat. Thus, to respond to the new threat, the international community has not only strengthened security and physical protection of radioactive materials but also established prevention of and response to illicit trafficking of radioactive materials. In this regard, our government has enacted or revised the national regulatory framework with a view to improving security of radioactive materials and joined the international convention or agreement to meet this international trend. For the purpose of prevention of nuclear/radiological terrorism, this paper reviews physical characteristics of nuclear material and existing detection instruments used for prevention of illicit trafficking. Finally, national detection regime against nuclear/radiological terrorism based on paths of the smuggled radioactive materials to terrorist's target building/area, national topography and road networks, and defence-in-depth concept is suggested in this paper. This study should contribute to protect people's health, safety and environment from nuclear/radiological terrorism

  1. Survival estimates for the passage of juvenile salmonids through Snake River dams and reservoirs, 1996. Annual report

    International Nuclear Information System (INIS)

    Smith, S.G.; Muir, W.D.; Hockersmith, E.E.; Achord, S.; Eppard, M.B.; Ruehle, T.E.; Williams, J.G.

    1998-02-01

    In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the major portion of their juvenile migrations. Specific research objectives in 1996 were to (1) estimate reach and project survival in the Snake River using the Single-Release and Paired-Release Models throughout the yearling chinook salmon and steelhead migrations, (2) evaluate the performance of the survival-estimation models under prevailing operational and environmental conditions in the Snake River, and (3) synthesize results from the 4 years of the study to investigate relationships between survival probabilities, travel times, and environmental factors such as flow levels and water temperature

  2. Survival Estimates for the Passage of Juvenile Salmonids through Snake River Dams and Reservoirs, 1996 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Steven G.

    1998-02-01

    In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the major portion of their juvenile migrations. Specific research objectives in 1996 were to (1) estimate reach and project survival in the Snake River using the Single-Release and Paired-Release Models throughout the yearling chinook salmon and steelhead migrations, (2) evaluate the performance of the survival-estimation models under prevailing operational and environmental conditions in the Snake River, and (3) synthesize results from the 4 years of the study to investigate relationships between survival probabilities, travel times, and environmental factors such as flow levels and water temperature.

  3. An in-depth study of sparse codes on abnormality detection

    DEFF Research Database (Denmark)

    Ren, Huamin; Pan, Hong; Olsen, Søren Ingvor

    2016-01-01

    Sparse representation has been applied successfully in abnormal event detection, in which the baseline is to learn a dictionary accompanied by sparse codes. While much emphasis is put on discriminative dictionary construction, there are no comparative studies of sparse codes regarding abnormality...... are carried out from various angles to better understand the applicability of sparse codes, including computation time, reconstruction error, sparsity, detection accuracy, and their performance combining various detection methods. The experiment results show that combining OMP codes with maximum coordinate...

  4. Can Markers Detect Contract Cheating? Results from a Pilot Study

    Science.gov (United States)

    Dawson, Phillip; Sutherland-Smith, Wendy

    2018-01-01

    Contract cheating is the purchasing of custom-made university assignments with the intention of submitting them. Websites providing contract cheating services often claim this form of cheating is undetectable, and no published research has examined this claim. This paper documents a pilot study where markers were paid to mark a mixture of real…

  5. A study to detect important factors influencing purchasing product: A case study of home appliances

    Directory of Open Access Journals (Sweden)

    Amir Ghafurian Shagerdi

    2013-07-01

    Full Text Available Home appliances are among basic requirements of anyone in the world and it is always important to find out about factors influencing this industry. Therefore, the purpose of this study is to provide a comprehensive model to detect major factors influencing on consumer purchasing intention. For this purpose, the proposed study designs a questionnaire and distributes it among 400 customers who have some experiences on purchasing home appliances in city of Tehran, Iran, recently. Cronbach alpha was calculated for all components of the survey and they were all well above the minimum acceptable level. We analyzed the data using structural equation modeling via LISREL and the results of this survey show that brand familiarity, brand trust, and perceived value have significant positive effects on consumers purchase intention.

  6. The evaluator effect in usability studies: Problem detection and severity judgments

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability studies are commonly used in industry and applied in research as a yardstick for other usability evaluation methods. Though usability studies have been studied extensively, one potential threat to their reliability has been left virtually untouched: the evaluator effect. In this study......, four evaluators individually analyzed four videotaped usability test sessions. Only 20% of the 93 detected problems were detected by all evaluators, and 46% were detected by only a single evaluator. From the total set of 93 problems the evaluators individually selected the ten problems they considered...... most severe. None of the selected severe problems appeared on all four evaluators’ top-10 lists, and 4 of the 11 problems that were considered severe by more than one evaluator were only detected by one or two evaluators. Thus, both detection of usability problems and selection of the most severe...

  7. An exploration study to detect important factors influencing internet marketing: A case study of food industry

    Directory of Open Access Journals (Sweden)

    Shadan Vahabzadeh

    2013-06-01

    Full Text Available Internet marketing plays an important role on profitability of organizations, it can build a bridge between customers and business owners and anyone could purchase products and services through internet. In this paper, we present an empirical investigation to detect important factors influencing internet marketing on Iranian food industry, named Shahrvand. The proposed study selects 280 out of 1040 managers who were involved in this industry during the year of 2012. Structural equation modeling has been performed to detect important factors including internal/external factors, ease of use and electronic marketing. Cronbach alphas have been calculated for these four items were mostly above 0.80, which validated the overall questionnaire of the survey. The results indicate that among internal factors, knowledge management, organizational culture and resources influence on acceptance of internet marketing, while these factors do not show any meaningful impact on ease of use. In addition, external factors including trend on market growth, competition and infrastructure influence on ease of use and acceptance of internet marketing but infrastructure and competition do not impact on ease of internet marketing.

  8. Simplified detection system for neuroreceptor studies in the human brain

    International Nuclear Information System (INIS)

    Bice, A.N.; Wagner, H.N. Jr.; Frost, J.J.

    1986-01-01

    A simple, inexpensive dual-detector system has been developed for measurement of positronemitting receptor-binding drugs in the human brain. This high efficiency coincidence counting system requires that only a few hundred microcuries of labeled drug be administered to the subject, thereby allowing for multiple studies without an excessive radiation dose. Measurement of the binding of [11C]carfentanil, a high affinity synthetic opiate, to opiate receptors in the presence and in the absence of a competitive opiate antagonist indicates the potential utility of this system for estimating different degrees of receptor occupation in the human brain

  9. Detecting congenital malformations - Lessons learned from the Mpepu study, Botswana.

    Directory of Open Access Journals (Sweden)

    Gbolahan Ajibola

    Full Text Available A large and increasing number of HIV-infected women are conceiving on antiretroviral treatment (ART. While most antiretrovirals are considered safe in pregnancy, monitoring for rare pregnancy and infant adverse outcomes is warranted.We conducted a retrospective secondary analysis nested within a clinical trial of infant cotrimoxazole vs. placebo prophylaxis in Botswana (the Mpepu Study. Infants were examined at birth, and at least every 3 months through 18 months of age. Abnormal physical findings and diagnostic testing revealing malformations were documented. Post hoc, a geneticist classified all reported malformations based on available documentation. Structural malformations with surgical, medical or cosmetic importance were classified as major malformations. We present a descriptive analysis of identified malformations.Between 2011 and 2014, 2,933 HIV-infected women who enrolled in the Mpepu study delivered 2,971 live-born infants. Study staff conducted 2,944 (99% newborn exams. One thousand eighty-eight (38% women were taking ART at conception; 1,147 (40% started ART during pregnancy; 442 (15% received zidovudine monotherapy; and 223 (7% received no antiretroviral during pregnancy. Of 33 reported anomalies, 25 (76% met congenital malformations criteria, 10 (30% were classified as major malformations, 4 (40% of which were identified after the birth exam.Our results highlight the importance of staff training on identification of congenital malformations, programmatic monitoring beyond the birth examination and the value of geneticist involvement in the malformations classification process in resource-limited settings. These elements will be important to fully define antiretroviral drug safety in pregnancy.Surveillance systems for monitoring the safety of antiretroviral use during pregnancy among HIV-infected women in resource-limited setting are lacking. The World Health Organization's published programmatic recommendations for such

  10. Clinical studies of 57Co-BLM for tumor detection

    International Nuclear Information System (INIS)

    Lee, Jhin Oh; Ryu, Yong Wun; Kim, Jang Hee

    1986-12-01

    Investigation with 57 Co-Bleomycin in patients with the various cancers and in tumor bearing animals are described. In the patients, 57 Co-Bleomycin appears to be one of the useful tumor-seeking radiopharmaceuticals, and worth applicable to clinical uses. Labelled yield of 57 Co-Bleo. was about 97% by thin layer chromatography. The pyrogen free tests were performed to meet U.S.P. critical ranges. In clinical studies with 57 Co-Bleo, 4 cases out of 5 patients with lung cancer, 2 cases among 3 thyroid cancer patients, and all 3 hepatoma patients showed positive tumor scans. The patients with stomach cancer, and the esophageal cancer showed false negative scintigraphy. A case with pulmonary tuberculosis showed a positive scan while liver abscess showed a negative picture. The merits of 57 Co-Bleomycin scintigraphy seems to be its relatively high affinity to tumors and low radiation hazard in spite of long physical half life. (Author)

  11. Study of the effect of environmental impact on land mine detection using nuclear techniques

    International Nuclear Information System (INIS)

    Aziz, M.; Massoud, E.

    2005-01-01

    Parameters that affect the accuracy of landmine detection using nuclear methods were analyzed. The influence of the soil type and water content on the detection processes were studied by calculating the backscattered neutron and gamma - rays at the detector. The difference at the detector between mines and several organic objects were calculated and analyzed

  12. Prospective comparative study of spiral computer tomography and magnetic resonance imaging for detection of hepatocellular carcinoma

    NARCIS (Netherlands)

    Stoker, J.; Romijn, M. G.; de Man, R. A.; Brouwer, J. T.; Weverling, G. J.; van Muiswinkel, J. M.; Zondervan, P. E.; Laméris, J. S.; Ijzermans, J. N. M.

    2002-01-01

    Background: Hepatocellular carcinoma (HCC) is often detected at a relatively late stage when tumour size prohibits curative surgery. Screening to detect HCC at an early stage is performed for patients at risk. Aim: The aim of this study was to compare prospectively the diagnostic accuracy and

  13. An Empirical Research Study of the Efficacy of Two Plagiarism-Detection Applications

    Science.gov (United States)

    Hill, Jacob D.; Page, Elaine Fetyko

    2009-01-01

    This article describes a study of the two most popular plagiarism-detection software platforms available on today's market--Turnitin (http://www.turnitin.com/static/index.html) and SafeAssign (http://www.safeassign.com/). After a brief discussion of plagiarism's relevance to librarians, the authors examine plagiarism-detection methodology and…

  14. MD2036: UFO Dynamics Studies and UFO Fast Detection

    CERN Document Server

    Belanger, Philippe; Valette, Matthieu; Lindstrom, Bjorn Hans Filip; Grob, Laura Katharina; Schmidt, Rudiger; Wollmann, Daniel

    2017-01-01

    UFOs are one of the remaining unknown related to LHC operation. Therefore, improving the understanding of UFO dynamics and validating the developed models against direct beam measurements is of fundamental importance in view of LHC operation at 7 TeV and with HL-LHC beam intensities. If not understood, UFOs could also be a showstopper for future machines such as FCC. This MD demonstrates new methods to study the dynamic behaviour of a calibrated UFO, simulated by the interaction of wire scanners with the beam. The events created during the MD were monitored using diamond BLMs in IR7, providing bunch-by-bunch resolution measurements. The analysis presented herein shows that blown-up bunches can be used to identify the plane of movement of UFOs, that bunch profiles and bunch sizes can be measured with dBLMs with good precision, that simulation of expected losses are in good agreement with measurements for oscillating bunches and that the space resolution of the acquisition system used during the MD is about 10 ...

  15. Studies on Methods for Detection of Salmonella SP. in Meat with Regard to Equivalency and Compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, P.; Smulders, F. J.M. [Institute for Meat Hygiene, Meat Technology and Food Science, University for Veterinary Medicine, Vienna (Austria); Girma, Z. [Addis Ababa University, Debre Zeit (Ethiopia); Farghaly, R. [South Valley University, Qena (Egypt)

    2005-01-15

    This contribution summarizes research activities on the evaluation of methods for detection of Salmonella in meat, especially poultry. The following items were under study: (1) studies on motility media for detection of Salmonella spp.: evaluation of MSRV media of different manufacturers; evaluation of novobiocine supplementation to MSRV and DIASALM media; abuse studies of incubation temperature; comparison of DIASALM medium vs. MSRV; (2) Salmonella antigen detection by a commercial EIA (Vidas System). The findings and information from other sources (references, technical papers) are to be combined in a database to give a comprehensive overview on the currently applied methodology. Basic considerations on the structure of this database are demonstrated. (author)

  16. The Power of Phase I Studies to Detect Clinical Relevant QTc Prolongation: A Resampling Simulation Study

    Directory of Open Access Journals (Sweden)

    Georg Ferber

    2015-01-01

    Full Text Available Concentration-effect (CE models applied to early clinical QT data from healthy subjects are described in the latest E14 Q&A document as promising analysis to characterise QTc prolongation. The challenges faced if one attempts to replace a TQT study by thorough ECG assessments in Phase I based on CE models are the assurance to obtain sufficient power and the establishment of a substitute for the positive control to show assay sensitivity providing protection against false negatives. To demonstrate that CE models in small studies can reliably predict the absence of an effect on QTc, we investigated the role of some key design features in the power of the analysis. Specifically, the form of the CE model, inclusion of subjects on placebo, and sparse sampling on the performance and power of this analysis were investigated. In this study, the simulations conducted by subsampling subjects from 3 different TQT studies showed that CE model with a treatment effect can be used to exclude small QTc effects. The number of placebo subjects was also shown to increase the power to detect an inactive drug preventing false positives while an effect can be underestimated if time points around tmax are missed.

  17. Survival estimates for the passage of juvenile chinook salmon through Snake River dams and reservoirs. Annual report 1993

    International Nuclear Information System (INIS)

    Iwamoto, R.N.; Muir, W.D.; Sandford, B.P.; McIntyre, K.W.; Frost, D.A.; Williams, J.G.; Smith, S.G.; Skalski, J.R.

    1994-04-01

    A pilot study was conducted to estimate survival of hatchery-reared yearling chinook salmon through dams and reservoirs on the Snake River. The goals of the study were to: (1) field test and evaluate the Single-Release, Modified-Single-Release, and Paired-Release Models for the estimation of survival probabilities through sections of a river and hydroelectric projects; (2) identify operational and logistical constraints to the execution of these models; and (3) determine the usefulness of the models in providing estimates of survival probabilities. Field testing indicated that the numbers of hatchery-reared yearling chinook salmon needed for accurate survival estimates could be collected at different areas with available gear and methods. For the primary evaluation, seven replicates of 830 to 1,442 hatchery-reared yearling chinook salmon were purse-seined from Lower Granite Reservoir, PIT tagged, and released near Nisqually John boat landing (River Kilometer 726). Secondary releases of PIT-tagged smolts were made at Lower Granite Dam to estimate survival of fish passing through turbines and after detection in the bypass system. Similar secondary releases were made at Little Goose Dam, but with additional releases through the spillway. Based on the success of the 1993 pilot study, the authors believe that the Single-Release and Paired-Release Models will provide accurate estimates of juvenile salmonid passage survival for individual river sections, reservoirs, and hydroelectric projects in the Columbia and Snake Rivers

  18. Survival Estimates for the Passage of Juvenile Chinook Salmon through Snake River Dams and Reservoirs, 1993 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, Robert N.; Sandford, Benjamin P.; McIntyre, Kenneth W.

    1994-04-01

    A pilot study was conducted to estimate survival of hatchery-reared yearling chinook salmon through dams and reservoirs on the Snake River. The goals of the study were to: (1) field test and evaluate the Single-Release, Modified-Single-Release, and Paired-Release Models for the estimation of survival probabilities through sections of a river and hydroelectric projects; (2) identify operational and logistical constraints to the execution of these models; and (3) determine the usefulness of the models in providing estimates of survival probabilities. Field testing indicated that the numbers of hatchery-reared yearling chinook salmon needed for accurate survival estimates could be collected at different areas with available gear and methods. For the primary evaluation, seven replicates of 830 to 1,442 hatchery-reared yearling chinook salmon were purse-seined from Lower Granite Reservoir, PIT tagged, and released near Nisqually John boat landing (River Kilometer 726). Secondary releases of PIT-tagged smolts were made at Lower Granite Dam to estimate survival of fish passing through turbines and after detection in the bypass system. Similar secondary releases were made at Little Goose Dam, but with additional releases through the spillway. Based on the success of the 1993 pilot study, the authors believe that the Single-Release and Paired-Release Models will provide accurate estimates of juvenile salmonid passage survival for individual river sections, reservoirs, and hydroelectric projects in the Columbia and Snake Rivers.

  19. A study on multi-data source fusion method for petroleum pipeline leak detection

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wei; Zhang, Laibin [Research Center of Oil and Gas Safety Engineering Technology, China University of Petroleum, Beijing, (China)

    2010-07-01

    The detection of leaks on petroleum pipeline is a very important safety issue. Several studies were commissioned to develop new monitoring procedures for leakage detection. This paper sets out a new leak detection process. The approach developed took into consideration steady and transient states. The study investigated leak diagnosis problems in product pipelines using multi-sensor measurements (pressure, flux, density and temperature). The information collected from each sensor was considered as pieces of evidence that describe the operational conditions of the pipeline. The Dempster-Shafer (D-S) theory is used to associate multi-sensor data to pipe health indices. Experimental pressure and flow rate data were recorded using a Pipeline Leak Detection System (PLDS) acquisition card and used to verify the accuracy and reliability of this new detection method. The results showed that the degree of credibility was a high as 0.877. It was also found that multi-feature information fusion improves recognition of pipeline conditions.

  20. Preliminary study on detection of irradiated foodstuffs from the Romanian market

    International Nuclear Information System (INIS)

    Cutrubinis, Mihalis; Chirita, Daniel; Savu, Diana; Elisabeta Secu, Corina; Mihai, Radu; Secu, Mihai; Ponta, Corneliu

    2007-01-01

    In order to fulfil the European task for market survey in food irradiation the first Romanian laboratory for detection of irradiated foodstuffs was established at IRASM Irradiation Centre. In this preliminary study, a wide range of Romanian food samples (spices, vegetables and meat) gamma irradiated at IRASM have been studied using different detection methods: (1) DNA comet assay, (2) thermoluminescence (TL) and (3) electron spin resonance (ESR) for foodstuffs containing bone or cellulose. The results suggest that there is no general available detection method and there is no perfect detection method. In conclusion, in order to carry out a correct identification of radiation treatment of a food sample it is recommended to use at least two standardised detection methods

  1. Camera trap arrays improve detection probability of wildlife: Investigating study design considerations using an empirical dataset.

    Science.gov (United States)

    O'Connor, Kelly M; Nathan, Lucas R; Liberati, Marjorie R; Tingley, Morgan W; Vokoun, Jason C; Rittenhouse, Tracy A G

    2017-01-01

    Camera trapping is a standard tool in ecological research and wildlife conservation. Study designs, particularly for small-bodied or cryptic wildlife species often attempt to boost low detection probabilities by using non-random camera placement or baited cameras, which may bias data, or incorrectly estimate detection and occupancy. We investigated the ability of non-baited, multi-camera arrays to increase detection probabilities of wildlife. Study design components were evaluated for their influence on wildlife detectability by iteratively parsing an empirical dataset (1) by different sizes of camera arrays deployed (1-10 cameras), and (2) by total season length (1-365 days). Four species from our dataset that represented a range of body sizes and differing degrees of presumed detectability based on life history traits were investigated: white-tailed deer (Odocoileus virginianus), bobcat (Lynx rufus), raccoon (Procyon lotor), and Virginia opossum (Didelphis virginiana). For all species, increasing from a single camera to a multi-camera array significantly improved detection probability across the range of season lengths and number of study sites evaluated. The use of a two camera array increased survey detection an average of 80% (range 40-128%) from the detection probability of a single camera across the four species. Species that were detected infrequently benefited most from a multiple-camera array, where the addition of up to eight cameras produced significant increases in detectability. However, for species detected at high frequencies, single cameras produced a season-long (i.e, the length of time over which cameras are deployed and actively monitored) detectability greater than 0.75. These results highlight the need for researchers to be critical about camera trap study designs based on their intended target species, as detectability for each focal species responded differently to array size and season length. We suggest that researchers a priori identify

  2. Camera trap arrays improve detection probability of wildlife: Investigating study design considerations using an empirical dataset.

    Directory of Open Access Journals (Sweden)

    Kelly M O'Connor

    Full Text Available Camera trapping is a standard tool in ecological research and wildlife conservation. Study designs, particularly for small-bodied or cryptic wildlife species often attempt to boost low detection probabilities by using non-random camera placement or baited cameras, which may bias data, or incorrectly estimate detection and occupancy. We investigated the ability of non-baited, multi-camera arrays to increase detection probabilities of wildlife. Study design components were evaluated for their influence on wildlife detectability by iteratively parsing an empirical dataset (1 by different sizes of camera arrays deployed (1-10 cameras, and (2 by total season length (1-365 days. Four species from our dataset that represented a range of body sizes and differing degrees of presumed detectability based on life history traits were investigated: white-tailed deer (Odocoileus virginianus, bobcat (Lynx rufus, raccoon (Procyon lotor, and Virginia opossum (Didelphis virginiana. For all species, increasing from a single camera to a multi-camera array significantly improved detection probability across the range of season lengths and number of study sites evaluated. The use of a two camera array increased survey detection an average of 80% (range 40-128% from the detection probability of a single camera across the four species. Species that were detected infrequently benefited most from a multiple-camera array, where the addition of up to eight cameras produced significant increases in detectability. However, for species detected at high frequencies, single cameras produced a season-long (i.e, the length of time over which cameras are deployed and actively monitored detectability greater than 0.75. These results highlight the need for researchers to be critical about camera trap study designs based on their intended target species, as detectability for each focal species responded differently to array size and season length. We suggest that researchers a priori

  3. Detection of radiation treatment of dry plant extracts by thermoluminescence and pulsed photostimulated luminescence. Comparative study

    International Nuclear Information System (INIS)

    Lehner, K.; Malec-Czechowska, K.; Stachowicz, W.; Guzik, G.

    2009-01-01

    Results of the examination of the variety of dry plant extracts (Thyme extract, Celery seed extract, Artichoke extract, Citrus aurantium extract and others) by two different detection methods are described. Both PSL and TL methods are presented and discussed. Comparative study based on the analysis of the results obtained by thermoluminescence (TL) and photostimulated luminescence (PSL) measurements delivered the arguments that preselection of detection methods based on model studies is rational to be adapted in analytical laboratories specialized in the detection of irradiated foods. (authors)

  4. Comparative study of adaptive-noise-cancellation algorithms for intrusion detection systems

    International Nuclear Information System (INIS)

    Claassen, J.P.; Patterson, M.M.

    1981-01-01

    Some intrusion detection systems are susceptible to nonstationary noise resulting in frequent nuisance alarms and poor detection when the noise is present. Adaptive inverse filtering for single channel systems and adaptive noise cancellation for two channel systems have both demonstrated good potential in removing correlated noise components prior detection. For such noise susceptible systems the suitability of a noise reduction algorithm must be established in a trade-off study weighing algorithm complexity against performance. The performance characteristics of several distinct classes of algorithms are established through comparative computer studies using real signals. The relative merits of the different algorithms are discussed in the light of the nature of intruder and noise signals

  5. Study of gamma detection capabilities of the REWARD mobile spectroscopic system

    Science.gov (United States)

    Balbuena, J. P.; Baptista, M.; Barros, S.; Dambacher, M.; Disch, C.; Fiederle, M.; Kuehn, S.; Parzefall, U.

    2017-07-01

    REWARD is a novel mobile spectroscopic radiation detector system for Homeland Security applications. The system integrates gamma and neutron detection equipped with wireless communication. A comprehensive simulation study on its gamma detection capabilities in different radioactive scenarios is presented in this work. The gamma detection unit consists of a precise energy resolution system based on two stacked (Cd,Zn)Te sensors working in coincidence sum mode. The volume of each of these CZT sensors is 1 cm3. The investigated energy windows used to determine the detection capabilities of the detector correspond to the gamma emissions from 137Cs and 60Co radioactive sources (662 keV and 1173/1333 keV respectively). Monte Carlo and Technology Computer-Aided Design (TCAD) simulations are combined to determine its sensing capabilities for different radiation sources and estimate the limits of detection of the sensing unit as a function of source activity for several shielding materials.

  6. Understanding environmental DNA detection probabilities: A case study using a stream-dwelling char Salvelinus fontinalis

    Science.gov (United States)

    Wilcox, Taylor M; Mckelvey, Kevin S.; Young, Michael K.; Sepulveda, Adam; Shepard, Bradley B.; Jane, Stephen F; Whiteley, Andrew R.; Lowe, Winsor H.; Schwartz, Michael K.

    2016-01-01

    Environmental DNA sampling (eDNA) has emerged as a powerful tool for detecting aquatic animals. Previous research suggests that eDNA methods are substantially more sensitive than traditional sampling. However, the factors influencing eDNA detection and the resulting sampling costs are still not well understood. Here we use multiple experiments to derive independent estimates of eDNA production rates and downstream persistence from brook trout (Salvelinus fontinalis) in streams. We use these estimates to parameterize models comparing the false negative detection rates of eDNA sampling and traditional backpack electrofishing. We find that using the protocols in this study eDNA had reasonable detection probabilities at extremely low animal densities (e.g., probability of detection 0.18 at densities of one fish per stream kilometer) and very high detection probabilities at population-level densities (e.g., probability of detection > 0.99 at densities of ≥ 3 fish per 100 m). This is substantially more sensitive than traditional electrofishing for determining the presence of brook trout and may translate into important cost savings when animals are rare. Our findings are consistent with a growing body of literature showing that eDNA sampling is a powerful tool for the detection of aquatic species, particularly those that are rare and difficult to sample using traditional methods.

  7. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    Directory of Open Access Journals (Sweden)

    Marie Sylvianne Rabodoarivelo

    2018-01-01

    Full Text Available Background: In low-income countries, rapid detection of tuberculosis (TB drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF and isoniazid (INH resistance. Methods: This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. Results: From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Conclusion: Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  8. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study.

    Science.gov (United States)

    Rabodoarivelo, Marie Sylvianne; Brandao, A; Cergole Novella, M C; C Bombonatte, A G; Imperiale, B; Rakotosamimanana, N; Morcillo, N; Rasolofo, V; Palomino, J C; Martin, A

    2018-01-01

    In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  9. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    International Nuclear Information System (INIS)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; You, Joshua H.; Lee, Ji Yong; Whang, Kum

    2010-01-01

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  10. Study on judgement baseline for XRF on-line detection system

    International Nuclear Information System (INIS)

    Zhang Quanshi; Bao Min

    2000-01-01

    Based on the Signal Detection Theory (SDT) and the statistics principle, the choice method of judgement baseline was studied. According to the characteristics of X-ray Fluorescence (XRF) spectra in the on-line detection system, the calculation methods for the characteristic peak of the element-tagged and background were carried out. The complex judgement baseline were rationally selected after a lot of experiments and analyzing. The operating results of near one year show that it is available

  11. Can Self-Censorship in News Media be Detected Algorithmically? A Case Study in Latin America

    OpenAIRE

    Tao, Rongrong; Zhou, Baojian; Chen, Feng; Liu, Naifeng; Mares, David; Butler, Patrick; Ramakrishnan, Naren

    2016-01-01

    Censorship in social media has been well studied and provides insight into how governments stifle freedom of expression online. Comparatively less (or no) attention has been paid to detecting (self) censorship in traditional media (e.g., news) using social media as a bellweather. We present a novel unsupervised approach that views social media as a sensor to detect censorship in news media wherein statistically significant differences between information published in the news media and the co...

  12. Detection of relapse in early stage Hodgkin's disease: role of routine follow up studies

    International Nuclear Information System (INIS)

    Torrey, Margaret J.; Poen, Joseph C.; Hoppe, Richard T.

    1995-01-01

    Purpose: To examine the costs and benefits of an established practice of routine follow-up in a cohort of patients treated with radiation therapy for early stage Hodgkin's disease. Materials and Methods: We retrospectively examined patterns of follow-up and methods of relapse detection among 709 patients with Ann Arbor Stage I-II Hodgkin's disease treated with sub-total lymphoid irradiation (STLI) or total lymphoid irradiation (TLI) between 1969-1994. We determined the probability of relapse detection for each of 7 routine follow up procedures, compared their relative costs, and determined the impact of each procedure on the likelihood of overall survival following salvage therapy. Results: Relapse has occurred in 157 patients (22%) at a median 1.9 years (range 0-13 years) following treatment. 133 relapses (85%) occurred during the first 5 years of follow. Detailed information concerning the method of relapse detection was available on 107 patients. These 107 patients form the basis of this analysis. Relapse was identified by history (Hx) alone in 55% of patients, physical exam (PE) in 14%, chest x-ray (CXR) in 23% and abdominal x-ray (KUB) in 7%. Only one relapse (1%) was identified by a routine laboratory study - erythrocyte sedimentation rate (ESR). The rate of relapse detection was highest for a combination of history and physical exam (78/10,000 exams) followed by CXR (26/10,000 exams), KUB (10/10,000 exams) and ESR (1/10,000 tests). Complete blood count (CBC) and serum chemistries were never the primary factor in detecting HD relapse. Radiographs accounted for greater than 60% of charges while laboratory studies and physician charges accounted for approximately 20% each. The projected charges (1994 dollars) of relapse detection by routine follow up Hx and PE was [dollar]10,600 compared with [dollar]68,200 for CXR, [dollar]141,800 for KUB and [dollar]156,400 for ESR. 10 year actuarial survival following salvage therapy was 65% overall, 65% for patients in whom

  13. Detection of relapse in early stage Hodgkin's disease: role of routine follow up studies

    Energy Technology Data Exchange (ETDEWEB)

    Torrey, Margaret J; Poen, Joseph C; Hoppe, Richard T

    1995-07-01

    Purpose: To examine the costs and benefits of an established practice of routine follow-up in a cohort of patients treated with radiation therapy for early stage Hodgkin's disease. Materials and Methods: We retrospectively examined patterns of follow-up and methods of relapse detection among 709 patients with Ann Arbor Stage I-II Hodgkin's disease treated with sub-total lymphoid irradiation (STLI) or total lymphoid irradiation (TLI) between 1969-1994. We determined the probability of relapse detection for each of 7 routine follow up procedures, compared their relative costs, and determined the impact of each procedure on the likelihood of overall survival following salvage therapy. Results: Relapse has occurred in 157 patients (22%) at a median 1.9 years (range 0-13 years) following treatment. 133 relapses (85%) occurred during the first 5 years of follow. Detailed information concerning the method of relapse detection was available on 107 patients. These 107 patients form the basis of this analysis. Relapse was identified by history (Hx) alone in 55% of patients, physical exam (PE) in 14%, chest x-ray (CXR) in 23% and abdominal x-ray (KUB) in 7%. Only one relapse (1%) was identified by a routine laboratory study - erythrocyte sedimentation rate (ESR). The rate of relapse detection was highest for a combination of history and physical exam (78/10,000 exams) followed by CXR (26/10,000 exams), KUB (10/10,000 exams) and ESR (1/10,000 tests). Complete blood count (CBC) and serum chemistries were never the primary factor in detecting HD relapse. Radiographs accounted for greater than 60% of charges while laboratory studies and physician charges accounted for approximately 20% each. The projected charges (1994 dollars) of relapse detection by routine follow up Hx and PE was [dollar]10,600 compared with [dollar]68,200 for CXR, [dollar]141,800 for KUB and [dollar]156,400 for ESR. 10 year actuarial survival following salvage therapy was 65% overall, 65% for patients in whom

  14. A detection system for charged-particle decay studies with a continuous-implantation method

    Energy Technology Data Exchange (ETDEWEB)

    Sun, L.J. [China Institute of Atomic Energy, Beijing 102413 (China); Xu, X.X., E-mail: xuxinxing@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Lin, C.J., E-mail: cjlin@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Wang, J.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Fang, D.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Z.H. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, Y.T. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, J. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Yang, L.; Ma, N.R. [China Institute of Atomic Energy, Beijing 102413 (China); Wang, K. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Zang, H.L. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, H.W.; Li, C.; Shi, C.Z.; Nie, M.W.; Li, X.F.; Li, H. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Ma, J.B.; Ma, P. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); and others

    2015-12-21

    A new detection system with high detection efficiency and low detection threshold has been developed for charged-particle decay studies, including β-delayed proton, α decay or direct proton emission from proton-rich nuclei. The performance was evaluated by using the β-delayed proton emitter {sup 24}Si produced by projectile fragmentation at the First Radioactive Ion Beam Line in Lanzhou. Under a continuous-beam mode, the isotopes of interest were implanted into two double-sided silicon strip detectors, where the subsequent decays were measured and correlated to the preceding implantations by using position and time information. The system allows us to measure protons with energies down to about 200 keV without obvious β background in the proton spectrum. Further application of the detection system can be extended to the measurements of β-delayed proton decay and the direct proton emission of more exotic proton-rich nuclei.

  15. Feasibility Study on Passive-radar Detection of Space Targets Using Spaceborne Illuminators of Opportunity

    Directory of Open Access Journals (Sweden)

    Jiang Tie-zhen

    2015-01-01

    Full Text Available Space target surveillance generally uses active radars. To take full advantage of passive radars, the idea of using spaceborne illuminators of opportunity for space target detection is presented in this paper. Analysis of the detectable time and direct wave suppression shows that passive radar using spaceborne illuminators of opportunity can effectively detect a Low-Earth-Orbit (LEO target. Meanwhile, Ku and L band bi-static radar cross section of passive radars that use spaceborne illuminators of opportunity are presented by simulation, providing the basis of choosing space target forward scatter. Finally the key parameters, mainly system gain, accumulation time and radiation source selection are studied. Results show that system size using satellite TV signals as illuminators of opportunity is relatively small. These encouraging results should stimulate the development of passive radar detection of space targets using spaceborne illuminators of opportunity.

  16. Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography

    International Nuclear Information System (INIS)

    Park, Hee Sang; Choi, Man Yong; Park, Jeong Hak; Lee, Seung Seok; Huh, Yong Hak; Lee, Bo Young; Jae Seong

    2012-01-01

    This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of 10 μm fine hair cracks. but, ultrasound infrared thermography technique was defect detected

  17. Results of Automated Retinal Image Analysis for Detection of Diabetic Retinopathy from the Nakuru Study, Kenya

    DEFF Research Database (Denmark)

    Juul Bøgelund Hansen, Morten; Abramoff, M. D.; Folk, J. C.

    2015-01-01

    Objective Digital retinal imaging is an established method of screening for diabetic retinopathy (DR). It has been established that currently about 1% of the world's blind or visually impaired is due to DR. However, the increasing prevalence of diabetes mellitus and DR is creating an increased...... workload on those with expertise in grading retinal images. Safe and reliable automated analysis of retinal images may support screening services worldwide. This study aimed to compare the Iowa Detection Program (IDP) ability to detect diabetic eye diseases (DED) to human grading carried out at Moorfields...... predictive value of IDP versus the human grader as reference standard. Results Altogether 3,460 participants were included. 113 had DED, giving a prevalence of 3.3%(95% CI, 2.7-3.9%). Sensitivity of the IDP to detect DED as by the human grading was 91.0%(95% CI, 88.0-93.4%). The IDP ability to detect DED...

  18. A New Study of Two Divergence Metrics for Change Detection in Data Streams

    KAUST Repository

    Qahtan, Abdulhakim Ali Ali; Wang, Suojin; Carroll, Raymond; Zhang, Xiangliang

    2014-01-01

    Streaming data are dynamic in nature with frequent changes. To detect such changes, most methods measure the difference between the data distributions in a current time window and a reference window. Divergence metrics and density estimation are required to measure the difference between the data distributions. Our study shows that the Kullback-Leibler (KL) divergence, the most popular metric for comparing distributions, fails to detect certain changes due to its asymmetric property and its dependence on the variance of the data. We thus consider two metrics for detecting changes in univariate data streams: a symmetric KL-divergence and a divergence metric measuring the intersection area of two distributions. The experimental results show that these two metrics lead to more accurate results in change detection than baseline methods such as Change Finder and using conventional KL-divergence.

  19. A New Study of Two Divergence Metrics for Change Detection in Data Streams

    KAUST Repository

    Qahtan, Abdulhakim Ali Ali

    2014-08-01

    Streaming data are dynamic in nature with frequent changes. To detect such changes, most methods measure the difference between the data distributions in a current time window and a reference window. Divergence metrics and density estimation are required to measure the difference between the data distributions. Our study shows that the Kullback-Leibler (KL) divergence, the most popular metric for comparing distributions, fails to detect certain changes due to its asymmetric property and its dependence on the variance of the data. We thus consider two metrics for detecting changes in univariate data streams: a symmetric KL-divergence and a divergence metric measuring the intersection area of two distributions. The experimental results show that these two metrics lead to more accurate results in change detection than baseline methods such as Change Finder and using conventional KL-divergence.

  20. Preliminary study on the detection of irradiated food containing bone by ESR spectroscopy

    International Nuclear Information System (INIS)

    Zhao Yongfu; Ha Yiming; Liu Ting; Wang Rongfu; Wang Changbao

    2007-01-01

    Electron spin resonance (ESR) spectroscopy is one of the most effective technique for detection of irradiated food containing bone. It was found that the radiation -induced ESR signal (Spectrum, g factor and peak-to-peak line width AH) in bone before and after irradiation was significantly different and could be easily distinguished from the endogenous ESR signal. Sample preparation studies showed vacuum drying and grinding at frozen temperature was an ideal method. A linear relationship was observed between ESR signal intensity and the absorbed dose (0.3-10.1kGy). It can be proposed that 0.5kGy absorbed doses can be detected by ESR for irradiated food containing bone though detecting sensitivity is very different at the same irradiated dosage with different food such as pork, beef, duck, chicken and fish. The ultimate purpose of this work is to establish a national criterion for detection of irradiated foodstuffs by use of ESR. (authors)

  1. Preliminary study of the use of radiotracers for leak detection in industrial applications

    International Nuclear Information System (INIS)

    Wetchagarun, S; Petchrak, A; Tippayakul, C

    2015-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH 4 Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system. (paper)

  2. Awareness on cytology procedure in oral cancer detection among undergraduates: An institutional study.

    Science.gov (United States)

    Ramesh, Gayathri; Pathak, Rajeev; Pathak, Sunita; Raj, Amrita; Kumar, Amit; Katiyar, Anuradha

    2017-11-01

    The screening and the early detection of the premalignant and malignant lesions are the only means for controlling the oral cancer which is known to be one of the leading causes for mortality worldwide. Oral exfoliative cytology though not a substitute for biopsy can be a powerful tool for its early detection. Dental Surgeons can play a great role in this direction. The present study was undertaken to assess the self-reported knowledge and attitude regarding the early detection of oral cancer and exfoliative cytology among the undergraduates of Rama Dental College, Kanpur. A pretested questionnaire based cross sectional study consisting of twenty four questions was conducted among hundred randomly selected students from third year, final year and intern's batch. According to 73% of students biopsy was the special test done in oral cancer detection and only 59% had heard regarding oral cytology technique. Formalin was the fixative known for cytology smears among 61%. Significance of toluidine blue staining was not known by 62%. Seventy seven percent of students were not aware about classes of cytology reporting. Eighty six percent of students felt that the adequacy of training in cytology was lagging. This survey identified an existing gap in the knowledge among the dental students regarding cytology as a diagnostic aid in oral cancer detection. This emphasizes the need to provide training for undergraduates at clinical level on regular basis and also through CDE and oral can-cer detection workshops.

  3. Preliminary study of the use of radiotracers for leak detection in industrial applications

    Science.gov (United States)

    Wetchagarun, S.; Petchrak, A.; Tippayakul, C.

    2015-05-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.

  4. Clinical study of 67Ga labelled human fibrinogen for detection of thrombi

    International Nuclear Information System (INIS)

    Katsuura, Yutaka

    1988-01-01

    The usefulness to detect thrombi by Ga-67 labelled human fibrinogen (Ga-F) was investigated in 22 patients with various diseases who had thrombi or were suspected to have thrombi. In 5 of 9 patients with aortic aneurysm, images of thrombi were obtained by Ga-F. In 1 of 2 patients with myocardial infarction, left ventricular thrombi were detected. In 1 of 5 patients with mitral stenosis, left atrial thrombus was recognized. Of these patients, in 2 patients who have no evidence of thrombi confirmed at another methods, thrombi were detected by Ga-F. In 6 out of 8 patients with thrombi confirmed at echocardiography or computed tomography, thrombi were detected by Ga-F. In these patients, 2 patients with negative images were treated by antithromboticdrugs. In 7 patients, both Ga-F and In-111 labelled platelets (In-P) were comparatively studied simultaniuosly. No difference in the sensitivity of the detection of thrombi were recognized between two groups. The images of thrombi by both Ga-F and In-P were detected positively in 3 patients and were not found in 4 patients. However, the handling of Ga-F method was much easier than that of In-P method. In conclusion, Ga-F could be useful for the detection of thrombi in various thrombotic diseases. Fibrinogen kinetic studies using Ga-F were performed. Fibrinogen turnover rates (FTR) in the cases with positive image by Ga-F were higher than those in the cases with Ga-F negative image. (positive : 24.3 ± 9.5 mg/kg/day, negative : 19.7 ± 8.5 mg/kg/day) The results of kinetic studies by Ga-F were similar to those by 1 - 125 fibrinogen. (author)

  5. Detection of pulmonary fat embolism with dual-energy CT: an experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhou, Chang Sheng; Zhao, Yan E.; Han, Zong Hong; Qi, Li; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Mangold, Stefanie; Ball, B.D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-04-15

    To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. (orig.)

  6. Studies on modeling to failed fuel detection system response in LMFBR

    International Nuclear Information System (INIS)

    Miyazawa, T.; Saji, G.; Mitsuzuku, N.; Hikichi, T.; Odo, T.; Rindo, H.

    1981-05-01

    Failed Fuel Detection (FFD) system with Fission Products (FP) detection is considered to be the most promissing method, since FP provides direct information against fuel element failure. For designing FFD system and for evaluating FFD signals, some adequate FFD signal response to fuel failure have been required. But few models are available in nowadays. Thus Power Reactor and Nuclear Fuel Development Corporation (PNC) had developed FFD response model with computer codes, based on several fundamental investigations on FP release and FP behavior, and referred to foreign country experiences on fuel failure. In developing the model, noble gas and halogen FP release and behavior were considered, since FFD system would be composed of both cover gas monitoring and delayed neutron monitoring. The developed model can provide typical fuel failure response and detection limit which depends on various background signals at cover gas monitoring and delayed neutron monitoring. According to the FFD response model, we tried to assume fuel failure response and detection limit at Japan experimental fast reactor ''JOYO''. The detection limit of JOYO FFD system was estimated by measuring the background signals. Followed on the studies, a complete computer code has been now made with some improvement. On the paper, the details of the model, out line of developed computer code, status of JOYO FFD system, and trial assumption of JOYO FFD response and detection limit. (author)

  7. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    Science.gov (United States)

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  8. Detection of methylated CDO1 in plasma of colorectal cancer; a PCR study.

    Directory of Open Access Journals (Sweden)

    Keishi Yamashita

    Full Text Available BACKGROUND: Cysteine biology is important for the chemosensitivity of cancer cells. Our research has focused on the epigenetic silencing of cysteine dioxygenase type 1 (CDO1 in colorectal cancer (CRC. In this study, we describe detection of CDO1 methylation in the plasma of CRC patients using methylation specific PCR (Q-MSP and extensive analysis of the PCR reaction. METHODS: DNA was extracted from plasma, and analysed for methylation of the CDO1 gene using Q-MSP. The detection rate of CDO1 gene methylation was calculated and compared with that of diluted DNA extracted from "positive control" DLD1 cells. CDO1 gene methylation in the plasma of 40 CRC patients that were clinicopathologically analysed was then determined. RESULTS: (1 The cloned sequence analysis detected 93.3% methylation of the promoter CpG islands of the CDO1 gene of positive control DLD1 cells and 4.7% methylation of the negative control HepG2 CDO1 gene. (2 DLD1 CDO1 DNA could not be detected in this assay if the extracted DNA was diluted ∼1000 fold. The more DNA that was used for the PCR reaction, the more effectively it was amplified in Q-MSP. (3 By increasing the amount of DNA used, methylated CDO1 could be clearly detected in the plasma of 8 (20% of the CRC patients. However, the percentage of CRC patients detected by methylated CDO1 in plasma was lower than that detected by CEA (35.9% or CA19-9 (23.1% in preoperative serum. Combination of CEA/CA19-9 plus plasma methylated CDO1 could increase the rate of detection of curable CRC patients (39.3% as compared to CEA/CA19-9 (25%. CONCLUSION: We have described detection of CDO1 methylation in the plasma of CRC patients. Although CDO1 methylation was not detected as frequently as conventional tumor markers, analysis of plasma CDO1 methylation in combination with CEA/CA19-9 levels increases the detection rate of curable CRC patients.

  9. Early detection of pharmacovigilance signals with automated methods based on false discovery rates: a comparative study.

    Science.gov (United States)

    Ahmed, Ismaïl; Thiessard, Frantz; Miremont-Salamé, Ghada; Haramburu, Françoise; Kreft-Jais, Carmen; Bégaud, Bernard; Tubert-Bitter, Pascale

    2012-06-01

    Improving the detection of drug safety signals has led several pharmacovigilance regulatory agencies to incorporate automated quantitative methods into their spontaneous reporting management systems. The three largest worldwide pharmacovigilance databases are routinely screened by the lower bound of the 95% confidence interval of proportional reporting ratio (PRR₀₂.₅), the 2.5% quantile of the Information Component (IC₀₂.₅) or the 5% quantile of the Gamma Poisson Shrinker (GPS₀₅). More recently, Bayesian and non-Bayesian False Discovery Rate (FDR)-based methods were proposed that address the arbitrariness of thresholds and allow for a built-in estimate of the FDR. These methods were also shown through simulation studies to be interesting alternatives to the currently used methods. The objective of this work was twofold. Based on an extensive retrospective study, we compared PRR₀₂.₅, GPS₀₅ and IC₀₂.₅ with two FDR-based methods derived from the Fisher's exact test and the GPS model (GPS(pH0) [posterior probability of the null hypothesis H₀ calculated from the Gamma Poisson Shrinker model]). Secondly, restricting the analysis to GPS(pH0), we aimed to evaluate the added value of using automated signal detection tools compared with 'traditional' methods, i.e. non-automated surveillance operated by pharmacovigilance experts. The analysis was performed sequentially, i.e. every month, and retrospectively on the whole French pharmacovigilance database over the period 1 January 1996-1 July 2002. Evaluation was based on a list of 243 reference signals (RSs) corresponding to investigations launched by the French Pharmacovigilance Technical Committee (PhVTC) during the same period. The comparison of detection methods was made on the basis of the number of RSs detected as well as the time to detection. Results comparing the five automated quantitative methods were in favour of GPS(pH0) in terms of both number of detections of true signals and

  10. Accuracy of spirometry for detection of asthma: a cross-sectional study.

    Science.gov (United States)

    Meneghini, Andréa Cristina; Paulino, Ana Carolina Botto; Pereira, Luciano Penha; Vianna, Elcio Oliveira

    2017-01-01

    Asthma is a chronic inflammatory disease with airway hyperresponsiveness. Spirometry is the most commonly used test among asthmatic patients. Another functional test used for diagnosing asthma is the bronchial challenge test. The aim of this study was to analyze the accuracy of spirometry for detecting asthma in the general population. Cross-sectional study with data analysis to evaluate the accuracy of spirometry through calculating sensitivity, specificity and predictive values and through the kappa agreement test. Subjects who constituted a birth cohort were enrolled at the age of 23 to 25 years. Spirometric abnormality was defined as reduced forced expiratory volume in one second, i.e. lower than 80% of the predicted value. Measurement of bronchial responsiveness was performed by means of the bronchial challenge test with methacholine. The gold-standard diagnosis of asthma was defined as the presence of bronchial hyperresponsiveness in association with respiratory symptoms. Asthma was detected in 200 subjects (10.4%) out of the sample of 1922 individuals. Spirometric abnormality was detected in 208 subjects (10.9%) of the sample. The specificity of spirometric abnormality for detecting asthma was 90%, sensitivity was 23%, positive predictive value was 22%, and negative predictive value was 91%. The kappa test revealed weak agreement of 0.13 (95% confidence interval, CI: 0.07-0.19) between spirometry and the diagnosis of asthma. Spirometry, as a single test, has limitations for detecting asthma in the general population.

  11. Detection of gas molecules on single Mn adatom adsorbed graphyne: a DFT-D study

    Science.gov (United States)

    Lu, Zhansheng; Lv, Peng; Ma, Dongwei; Yang, Xinwei; Li, Shuo; Yang, Zongxian

    2018-02-01

    As one of the prominent applications in intelligent systems, gas sensing technology has attracted great interest in both industry and academia. In the current study, the pristine graphyne (GY) without and with a single Mn atom is investigated to detect the gas molecules (CO, CH4, CO2, NH3, NO and O2). The pristine GY is promising to detect O2 molecules because of its chemical adsorption on GY with large electron transfer. The great stability of the Mn/GY is found, and the Mn atom prefers to anchor at the alkyne ring as a single atom. Upon single Mn atom anchoring, the sensitivity and selectivity of GY based gas sensors is significantly improved for various molecules, except CH4. The recovery time of the Mn/GY after detecting the gas molecules may help to appraise the detection efficiency for the Mn/GY. The current study will help to understand the mechanism of detecting the gas molecules, and extend the potentially fascinating applications of GY-based materials.

  12. A subtraction pipeline for automatic detection of new appearing multiple sclerosis lesions in longitudinal studies

    Energy Technology Data Exchange (ETDEWEB)

    Ganiler, Onur; Oliver, Arnau; Diez, Yago; Freixenet, Jordi; Llado, Xavier [University of Girona, VICOROB Computer Vision and Robotics Group, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Beltran, Brigitte [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2014-05-15

    Time-series analysis of magnetic resonance images (MRI) is of great value for multiple sclerosis (MS) diagnosis and follow-up. In this paper, we present an unsupervised subtraction approach which incorporates multisequence information to deal with the detection of new MS lesions in longitudinal studies. The proposed pipeline for detecting new lesions consists of the following steps: skull stripping, bias field correction, histogram matching, registration, white matter masking, image subtraction, automated thresholding, and postprocessing. We also combine the results of PD-w and T2-w images to reduce false positive detections. Experimental tests are performed in 20 MS patients with two temporal studies separated 12 (12M) or 48 (48M) months in time. The pipeline achieves very good performance obtaining an overall sensitivity of 0.83 and 0.77 with a false discovery rate (FDR) of 0.14 and 0.18 for the 12M and 48M datasets, respectively. The most difficult situation for the pipeline is the detection of very small lesions where the obtained sensitivity is lower and the FDR higher. Our fully automated approach is robust and accurate, allowing detection of new appearing MS lesions. We believe that the pipeline can be applied to large collections of images and also be easily adapted to monitor other brain pathologies. (orig.)

  13. A FEASIBILITY STUDY ON USE OF GENERIC MOBILE LASER SCANNING SYSTEM FOR DETECTING ASPHALT PAVEMENT CRACKS

    Directory of Open Access Journals (Sweden)

    X. Chen

    2016-06-01

    Full Text Available This study aims to automatically detect pavement cracks on urban roads by employing the 3D point clouds acquired by a mobile laser scanning (MLS system. Our method consists of four steps: ground point filtering, high-pass convolution, matched filtering, and noise removal. First, a voxel-based upward growing method is applied to construct Digital Terrain Model (DTM of the road surface. Then, a high-pass filter convolutes the DTM to detect local elevation changes that may embed cracking information. Next, a two-step matched filter is applied to extract crack features. Lastly, a noise removal process is conducted to refine the results. Instead of using MLS intensity, this study takes advantages of the MLS elevation information to perform automated crack detection from large-volume, mixed-density, unstructured MLS point clouds. Four types of cracks including longitudinal, transvers, random, and alligator cracks are detected. Our results demonstrated that the proposed method works well with the RIEGL VMX-450 point clouds and can detect cracks in moderate-to-severe severity (13 - 25 mm within a 200 m by 30 m urban road segment located in Kingston, Ontario, at one time. Due to the resolution capability, small cracks with slight severity remain unclear in the MLS point cloud.

  14. Incidentally detected thyrotoxicosis-etiology and natural course: A study from Central Kerala

    Directory of Open Access Journals (Sweden)

    Rajeev Philip

    2016-01-01

    Full Text Available Context: Thyrotoxicosis is a common clinical problem, and the most common cause of thyrotoxicosis is Graves′ disease and is 4 times more common than the other causes combined. Of late, the number of people incidentally detected to have biochemical thyrotoxicosis is increasing, and most patients are detected during health checkups, pregnancy planning, and surgical fitness. There are no data on the etiology and natural course of such cases and no guidelines for evaluation of such patients. Aims: The aim of this study is to evaluate the cause of thyrotoxicosis in patients incidentally detected to have biochemical thyrotoxicosis and to study the natural course of illness of these patients. Subjects and Methods: All patients who were incidentally detected to have biochemical thyrotoxicosis (during health checkups, pregnancy planning, and surgical fitness were included and studied. Patients who had symptoms of thyrotoxicosis, or patients in whom thyrotoxicosis was suspected by the treating doctor were excluded from the study. All patients underwent an ultrasound thyroid and thyroid scan, and treatment was decided based on the results. All patients were followed up for a minimum period of 3 months. Results: A total of 57 patients were studied. The average age of the study population was 32.8 years, with male:female ratio of 1:3.3. Of 57 patients, 52 (91% had subacute thyroiditis as the cause of thyrotoxicosis while Graves′ disease was seen in 9%. None had toxic adenoma or toxic multinodular goiter. In the patients with subacute thyroiditis, 47 became euthyroid and 5 became subclinically hypothyroid (Stage b. Conclusions: The majority of patients with incidentally detected thyrotoxicosis had thyroiditis as the cause, which reverted to euthyroid state in most of the cases. Based on the study, it seems prudent to wait and follow up this group of patients rather than start antithyroid drugs, especially if facilities for uptake scan are not available or

  15. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    OpenAIRE

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat cont...

  16. Lung cancer detection with digital chest tomosynthesis: first round results from the SOS observational study.

    Science.gov (United States)

    Bertolaccini, Luca; Viti, Andrea; Tavella, Chiara; Priotto, Roberto; Ghirardo, Donatella; Grosso, Maurizio; Terzi, Alberto

    2015-04-01

    Baseline results of the Studio OSservazionale (SOS), observational study, a single-arm observational study of digital chest tomosynthesis for lung cancer detection in an at-risk population demonstrated a detection rate of lung cancer comparable to that of studies that used low dose CT scan (LDCT). We present the results of the first round. Totally 1,703 out of 1,843 (92%) subjects who had a baseline digital chest tomosynthesis underwent a first round reevaluation after 1 year. At first round chest digital tomosynthesis, 13 (0.7%) subjects had an indeterminate nodule larger than 5 mm and underwent low-dose CT scan for nodule confirmation. PET/CT study was obtained in 10 (0.5%) subjects and 2 subjects had a low-dose CT follow up. Surgery, either video-assisted thoracoscopic or open surgery for indeterminate pulmonary nodules was performed in 10 (0.2%) subjects. A lung cancer was diagnosed and resected in five patients. The lung cancer detection rate at first round was 0.3% (5/1,703). The detection rate of lung cancer at first round for tomosynthesis is comparable to rates reported for CT. In addition, results of first round digital chest tomosynthesis confirm chest tomosynthesis as a possible first-line lung cancer-screening tool.

  17. A Study on Damage Detection Using Output-Only Modal Data

    DEFF Research Database (Denmark)

    Kharrazi, M. K. H.; Ventura, Carlos E.; Brincker, Rune

    2002-01-01

    detection using output-only data from the vibration study. A one-third scale model of a four story steel frame at the University of British Columbia was used as the test specimen. A series of forced and ambient vibration tests on this frame for various levels of damage were conducted. Damage was simulated...

  18. Natural history of breast cancers detected in the Swedish mammography screening programme: a cohort study

    DEFF Research Database (Denmark)

    Zahl, Per-Henrik; Gøtzsche, Peter C; Mæhlen, Jan

    2011-01-01

    The natural history of screen-detected breast cancers is not well understood. A previous analysis of the incidence change during the introduction of the Norwegian screening programme in the late 1990s suggested that the natural history of many screen-detected invasive breast cancers is to regress...... spontaneously but the study was possibly confounded by use of hormone replacement therapy in the population. We did a similar analysis of data collected during an earlier period when few women were exposed to hormone replacement therapy....

  19. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation (least squares and filtering) methods

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the Primary circuit water inventory of a pressurized water reactor. A reference model is developed for the development of an automatic system ensuring detection and real-time diagnostic. The methods to our application are statistical tests and adapted a pattern recognition method. The estimation of the detected anomalies is treated by the least square fit method, and by filtering. A new projected optimization method with superlinear convergence is developed in this framework, and a segmented linearization of the model is introduced, in view of a multiple filtering. 46 refs [fr

  20. Idaho Steelhead Monitoring and Evaluation Studies : Annual Progress Report 2007.

    Energy Technology Data Exchange (ETDEWEB)

    Copeland, Timothy; Putnam, Scott

    2008-12-01

    The goal of Idaho Steelhead Monitoring and Evaluation Studies is to collect monitoring data to evaluate wild and natural steelhead populations in the Clearwater and Salmon river drainages. During 2007, intensive population data were collected in Fish Creek (Lochsa River tributary) and Rapid River (Little Salmon River tributary); extensive data were collected in other selected spawning tributaries. Weirs were operated in Fish Creek and Rapid River to estimate adult escapement and to collect samples for age determination and genetic analysis. Snorkel surveys were conducted in Fish Creek, Rapid River, and Boulder Creek (Little Salmon River tributary) to estimate parr density. Screw traps were operated in Fish Creek, Rapid River, Secesh River, and Big Creek to estimate juvenile emigrant abundance, to tag fish for survival estimation, and to collect samples for age determination and genetic analysis. The estimated wild adult steelhead escapement in Fish Creek was 81 fish and in Rapid River was 32 fish. We estimate that juvenile emigration was 24,127 fish from Fish Creek; 5,632 fish from Rapid River; and 43,674 fish from Big Creek. The Secesh trap was pulled for an extended period due to wildfires, so we did not estimate emigrant abundance for that location. In cooperation with Idaho Supplementation Studies, trap tenders PIT tagged 25,618 steelhead juveniles at 18 screw trap sites in the Clearwater and Salmon river drainages. To estimate age composition, 143 adult steelhead and 5,082 juvenile steelhead scale samples were collected. At the time of this report, 114 adult and 1,642 juvenile samples have been aged. Project personnel collected genetic samples from 122 adults and 839 juveniles. We sent 678 genetic samples to the IDFG Eagle Fish Genetics Laboratory for analysis. Water temperature was recorded at 37 locations in the Clearwater and Salmon river drainages.

  1. Proof-of-concept experimental study of damage detection of concrete piles using embedded piezoceramic transducers

    International Nuclear Information System (INIS)

    Wang, R L; Gu, H; Song, G; Mo, Y L

    2013-01-01

    This paper presents a proof-of-concept experimental study of an innovative active-sensing approach for damage detection of concrete piles by using embedded piezoceramic transducers. In the proposed active-sensing approach, one piezoceramic transducer is used as an actuator to generate a stress wave to propagate through the concrete pile and the other distributed piezoceramic transducers are used as sensors to detect the wave response. Cracks or damage inside the concrete structure act as stress relief in the wave propagation path. The amplitude of the wave and the transmission energy will decrease due to the existence of cracks or damage. Experiments were performed on two bored piles instrumented with embedded piezoceramic transducers. The experimental results demonstrate the effectiveness of the proposed approach for pile damage detection. (fast track communication)

  2. Experimental study on flaw detectability of remote field eddy current testing

    International Nuclear Information System (INIS)

    Kamimura, T.; Fukui, S.; Iwahashi, Y.; Yamada, H.

    1988-01-01

    For the purpose of comprehending the effect in practical use of the remote field eddy current (RFEC) testing that becomes noticeable for the ISI technique of steel tubes, its flaw detectability was clarified through a model test. This study used straight and bending tubes of 3.8 mm in wall thickness and 31.8 mm in outside diameter. These tubes were inspected from their inside. After relations among the pickup coil output, coil distance, testing frequency, etc. were measured, a probe of the practical use type was manufactured to investigate its flaw detectability by means of simulated flaws. The authors discuss how it has been found that light local wall thinning on the outside surfaces can be detected by this technique and its effect in practical use can be expected with small influences due to magnetic permeability variations of tube materials, bending of tubes, etc

  3. Contribution to the study of a new X-ray detection method for medical imaging

    International Nuclear Information System (INIS)

    Bouteiller, Patrick.

    1977-01-01

    The present work is part of a joint effort to develop a quick and efficient tomographic technique. Our research is devoted to the feasibility of a new detection method applicable to such apparatus with a view to the short- or medium-term industrial development of these techniques. Following an outline of the basic principles of this image reconstruction method the fundamental parameters governing the choice of detection system are defined. Part two gives results relating to the first solutions examined and to their limits and disadvantages from the viewpoint of a possible industrial application. Part three reports and justifies, both theoretically and experimentally, a choice of detection method using a high-pressure gas ionisation chamber. Part four describes our participation in the building of an industrial prototype and the additional problems encountered. The final part deals with possibilities of improving the system either by perfecting the above methods or after studies on new structures developed in the laboratory [fr

  4. Thin layer chromatographic method for the detection of uric acid: collaborative study.

    Science.gov (United States)

    Thrasher, J J; Abadie, A

    1978-07-01

    A collaborative study has been completed on an improved method for the detection and confirmation of uric acid from bird and insect excreta. The proposed method involves the lithium carbonate solubilization of the suspect excreta material, followed by butanol-methanol-water-acetic acid thin layer chromatography, and trisodium phosphate-phosphotungstic acid color development. The collaborative tests resulted in 100% detection of uric acid standard at the 50 ng level and 75% detection at the 20-25 ng level. No false positives were reported during tests of compounds similar to uric acid. The proposed method has been adopted official first action; the present official final action method, 44.161, will be retained for screening purposes.

  5. Study of relationship between MUF correlation and detection sensitivity of statistical analysis

    International Nuclear Information System (INIS)

    Tamura, Toshiaki; Ihara, Hitoshi; Yamamoto, Yoichi; Ikawa, Koji

    1989-11-01

    Various kinds of statistical analysis are proposed to NRTA (Near Real Time Materials Accountancy) which was devised to satisfy the timeliness goal of one of the detection goals of IAEA. It will be presumed that different statistical analysis results will occur between the case of considered rigorous error propagation (with MUF correlation) and the case of simplified error propagation (without MUF correlation). Therefore, measurement simulation and decision analysis were done using flow simulation of 800 MTHM/Y model reprocessing plant, and relationship between MUF correlation and detection sensitivity and false alarm of statistical analysis was studied. Specific character of material accountancy for 800 MTHM/Y model reprocessing plant was grasped by this simulation. It also became clear that MUF correlation decreases not only false alarm but also detection probability for protracted loss in case of CUMUF test and Page's test applied to NRTA. (author)

  6. Preliminary study of diagnostic workstation with different matrix size for detection of small pulmonary nodules

    International Nuclear Information System (INIS)

    Wu Jie; Wang Xuejian; Wang Bo; Tong Juan; Wei Yuqing; Shen Guiquan; Wang Limei; Cao Jun; Sui He

    2004-01-01

    Objective: To assess the influence in detecting small pulmonary nodules (SPNs) on soft-copy images displayed with different matrix sizes. Methods: Seventy-six chest compute radiographs were selected for the study. Of the 76 test images, 36 pulmonary nodules smaller than 20 mm in diameter were proven by CT, which were further divided into two groups: 1.0-2.0 cm and Z values and standard error of three kinds of view system for individual observers. Results: For 1.0-2.0 cm group, the mean A Z values were 0.7936 for DRCS with 2-fold magnification and window technique, 0.8225 for 1 K monitor with 2-fold magnification and window technique, and 0.8367 for 2 K monitor without magnification; for Z values increased slightly as the display matrix size improved, but there were no significant differences among the three sets in the detection of SPNs in the ROC analyses. Conclusion: It is acceptable to detect small pulmonary nodules of 1.0-2.0 cm in diameter on 1 K monitor and DRCS with magnification. High resolution diagnostic workstation is recommended for detecting small pulmonary nodules <1.0 cm in diameter. Reasonable equipment for the detection of subtle abnormality may result in better cost-efficacy and diagnostic accuracy

  7. In-vitro studies of change in edge detection with changes in bone density

    International Nuclear Information System (INIS)

    Pocock, N.; Noakes, K.; Griffiths, M.

    1999-01-01

    Full text: Dual energy X-ray absorptiometry (DXA) requires edge detection software to identify the skeletal regions for quantitation of bone mineral density (BMD) and bone mineral content (BMC). As bone mass decreases, the detection of bone edges becomes more difficult and this potentially could cause errors in DXA estimations of areal BMD or BMC. To address this issue, we have used an in-vitro model to study the effects of 'bone loss' on calculated bone area, BMD and BMC. Multiple vertebral phantoms, of equal cross-sectional area but incrementally decreased areal BMD, were constructed using calcium sulphate hemihydrate. The weight of each phantom vertebra, measured accurately using an electronic balance, was used as an index of its true 'bone mass equivalent' (BME). The phantoms were scanned and analysed in the lumbar spine mode using a Lunar DPX-L (L) and Hologic QDR-1000 (H). The changes in BME were compared to changes in measured area, BMC and areal BMD. The results demonstrate that, in an in-vitro model, as bone mass decreases, measured bone area and consequently BMC will decrease as the edge detection algorithms have greater difficulty in detecting the true edges. In conclusion, in an in-vitro model, the DXA edge detection algorithms will underestimate bone area as bone mass decreases. This has potential implications for monitoring changes in bone mass in vivo

  8. Study on Method of Geohazard Change Detection Based on Integrating Remote Sensing and GIS

    International Nuclear Information System (INIS)

    Zhao, Zhenzhen; Yan, Qin; Liu, Zhengjun; Luo, Chengfeng

    2014-01-01

    Following a comprehensive literature review, this paper looks at analysis of geohazard using remote sensing information. This paper compares the basic types and methods of change detection, explores the basic principle of common methods and makes an respective analysis of the characteristics and shortcomings of the commonly used methods in the application of geohazard. Using the earthquake in JieGu as a case study, this paper proposes a geohazard change detection method integrating RS and GIS. When detecting the pre-earthquake and post-earthquake remote sensing images at different phases, it is crucial to set an appropriate threshold. The method adopts a self-adapting determination algorithm for threshold. We select a training region which is obtained after pixel information comparison and set a threshold value. The threshold value separates the changed pixel maximum. Then we apply the threshold value to the entire image, which could also make change detection accuracy maximum. Finally, we output the result to the GIS system to make change analysis. The experimental results show that this method of geohazard change detection based on integrating remote sensing and GIS information has higher accuracy with obvious advantages compared with the traditional methods

  9. Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Lell, M.; Boehner, C.; Bautz, W.A.; Mertelmeier, T.

    2006-01-01

    Purpose: To compare the sensitivity of conventional two-dimensional (2D) projection imaging with tomosynthesis with respect to the detectability of mammographic phantom lesions. Materials and Methods: Using a breast tomosynthesis prototype based on a commercial FFDM system (Siemens MAMMOMAT Novation DR ), but modified for a wide angle tube motion and equipped with a fast read-out amorphous selenium detector, we acquired standard 2D images and tomosynthesis series of projection views. We used the Wisconsin mammographic random phantom, model RMI 152A. The anode filter combinations Mo/Mo and W/Rh at two different doses were used as typical radiographic techniques. Slice images through the phantom parallel to the detector were reconstructed with a distance of 1 mm employing a filtered back-projection algorithm. The image data sets were read by five radiologists and evaluated with respect to the detectability of the phantom details. Results: For all studied radiographic techniques, the detection rate in the tomosynthesis mode was 100%, i.e. 75 true positive findings out of 75 possible hits. In contrast, the conventional projection mode yielded a detection rate between 80 and 93% (corresponding to 60 and 70 detected details) depending on the dose and X-ray spectrum. Conclusion: Tomosynthesis has the potential to increase the sensitivity of digital mammography. Overlapping structures from out-of-plane tissue can be removed in the tomosynthesis reconstruction process, thereby enhancing the diagnostic accuracy. (orig.)

  10. Study on the defects detection in composites by using optical position and infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Kwn, Koo Ahn; Choi, Man Yong; Park, Jeong Hak; Choi, Won Jae [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, Hee Sang [Dept. of Research and Development, Korea Research Institute of Smart Material and Structures System Association, Daejeon (Korea, Republic of)

    2016-04-15

    Non-destructive testing methods for composite materials (e.g., carbon fiber-reinforced and glass fiber-reinforced plastic) have been widely used to detect damage in the overall industry. This study detects defects using optical infrared thermography. The transient heat transport in a solid body is characterized by two dynamic quantities, namely, thermal diffusivity and thermal effusivity. The first quantity describes the speed with thermal energy diffuses through a material, whereas the second one represents a type of thermal inertia. The defect detection rate is increased by utilizing a lock-in method and performing a comparison of the defect detection rates. The comparison is conducted by dividing the irradiation method into reflection and transmission methods and the irradiation time into 50 mHz and 100 mHz. The experimental results show that detecting defects at 50 mHz is easy using the transmission method. This result implies that low-frequency thermal waves penetrate a material deeper than the high-frequency waves.

  11. A comparison study on algorithms of detecting long forms for short forms in biomedical text

    Directory of Open Access Journals (Sweden)

    Wu Cathy H

    2007-11-01

    Full Text Available Abstract Motivation With more and more research dedicated to literature mining in the biomedical domain, more and more systems are available for people to choose from when building literature mining applications. In this study, we focus on one specific kind of literature mining task, i.e., detecting definitions of acronyms, abbreviations, and symbols in biomedical text. We denote acronyms, abbreviations, and symbols as short forms (SFs and their corresponding definitions as long forms (LFs. The study was designed to answer the following questions; i how well a system performs in detecting LFs from novel text, ii what the coverage is for various terminological knowledge bases in including SFs as synonyms of their LFs, and iii how to combine results from various SF knowledge bases. Method We evaluated the following three publicly available detection systems in detecting LFs for SFs: i a handcrafted pattern/rule based system by Ao and Takagi, ALICE, ii a machine learning system by Chang et al., and iii a simple alignment-based program by Schwartz and Hearst. In addition, we investigated the conceptual coverage of two terminological knowledge bases: i the UMLS (the Unified Medical Language System, and ii the BioThesaurus (a thesaurus of names for all UniProt protein records. We also implemented a web interface that provides a virtual integration of various SF knowledge bases. Results We found that detection systems agree with each other on most cases, and the existing terminological knowledge bases have a good coverage of synonymous relationship for frequently defined LFs. The web interface allows people to detect SF definitions from text and to search several SF knowledge bases. Availability The web site is http://gauss.dbb.georgetown.edu/liblab/SFThesaurus.

  12. Concept Study of Multi Sensor Detection Imaging and Explosive Confirmation of Mines

    National Research Council Canada - National Science Library

    Stolarczyk, Larry

    1998-01-01

    ...) cannot detect non-metallic mines and detection sensitivity degrades in magnetic soil. Because metal detection sensitivity can be increased to detect low metal content in some non-metallic mines, some alarms significantly increase...

  13. Detecting Smoking Events Using Accelerometer Data Collected Via Smartwatch Technology: Validation Study.

    Science.gov (United States)

    Cole, Casey A; Anshari, Dien; Lambert, Victoria; Thrasher, James F; Valafar, Homayoun

    2017-12-13

    Smoking is the leading cause of preventable death in the world today. Ecological research on smoking in context currently relies on self-reported smoking behavior. Emerging smartwatch technology may more objectively measure smoking behavior by automatically detecting smoking sessions using robust machine learning models. This study aimed to examine the feasibility of detecting smoking behavior using smartwatches. The second aim of this study was to compare the success of observing smoking behavior with smartwatches to that of conventional self-reporting. A convenience sample of smokers was recruited for this study. Participants (N=10) recorded 12 hours of accelerometer data using a mobile phone and smartwatch. During these 12 hours, they engaged in various daily activities, including smoking, for which they logged the beginning and end of each smoking session. Raw data were classified as either smoking or nonsmoking using a machine learning model for pattern recognition. The accuracy of the model was evaluated by comparing the output with a detailed description of a modeled smoking session. In total, 120 hours of data were collected from participants and analyzed. The accuracy of self-reported smoking was approximately 78% (96/123). Our model was successful in detecting 100 of 123 (81%) smoking sessions recorded by participants. After eliminating sessions from the participants that did not adhere to study protocols, the true positive detection rate of the smartwatch based-detection increased to more than 90%. During the 120 hours of combined observation time, only 22 false positive smoking sessions were detected resulting in a 2.8% false positive rate. Smartwatch technology can provide an accurate, nonintrusive means of monitoring smoking behavior in natural contexts. The use of machine learning algorithms for passively detecting smoking sessions may enrich ecological momentary assessment protocols and cessation intervention studies that often rely on self

  14. THE ANALYSIS OF DETECTIVE GENRE IN MEDIA STUDIES IN THE STUDENT AUDIENCE

    Directory of Open Access Journals (Sweden)

    Alexander Fedorov

    2011-11-01

    Full Text Available Development of skills for the critical analysis of media texts - an important task of media education. However, media literacy practice shows that students have the problems with the discussion / analysis of entertainment genres in the early stages of media studies, for example, the difficulties in the process of understanding and interpreting the author's conception, plot and genre features. This article substantiates the methodological approaches to the analysis skills of detective/thriller genre in media studies in the student audience.

  15. Breast density and mode of detection in relation to breast cancer specific survival: a cohort study

    International Nuclear Information System (INIS)

    Olsson, Åsa; Sartor, Hanna; Borgquist, Signe; Zackrisson, Sophia; Manjer, Jonas

    2014-01-01

    The aim of this study was to examine breast density in relation to breast cancer specific survival and to assess if this potential association was modified by mode of detection. An additional aim was to study whether the established association between mode of detection and survival is modified by breast density. The study included 619 cases from a prospective cohort, The Malmö Diet and Cancer Study. Breast density estimated qualitatively, was analyzed in relation to breast cancer death, in non-symptomatic and symptomatic women, using Cox regression calculating hazard ratios (HR) with 95% confidence intervals. Adjustments were made in several steps for; diagnostic age, tumour size, axillary lymph node involvement, grade, hormone receptor status, body mass index (baseline), diagnostic period, use of hormone replacement therapy at diagnosis and mode of detection. Detection mode in relation to survival was analyzed stratified for breast density. Differences in HR following different adjustments were analyzed by Freedmans%. After adjustment for age and other prognostic factors, women with dense, as compared to fatty breasts, had an increased risk of breast cancer death, HR 2.56:1.07-6.11, with a statistically significant trend over density categories, p = 0.04. In the stratified analysis, the effect was less pronounced in non-symptomatic women, HR 2.04:0.49-8.49 as compared to symptomatic, HR 3.40:1.06-10.90. In the unadjusted model, symptomatic women had a higher risk of breast cancer death, regardless of breast density. Analyzed by Freedmans%, age, tumour size, lymph nodes, grade, diagnostic period, ER and PgR explained 55.5% of the observed differences in mortality between non-symptomatic and symptomatic cases. Additional adjustment for breast density caused only a minor change. High breast density at diagnosis may be associated with decreased breast cancer survival. This association appears to be stronger in women with symptomatic cancers but breast density could

  16. Data-driven drug safety signal detection methods in pharmacovigilance using electronic primary care records: A population based study

    Directory of Open Access Journals (Sweden)

    Shang-Ming Zhou

    2017-04-01

    Data-driven analytic methods are a valuable aid to signal detection of ADEs from large electronic health records for drug safety monitoring. This study finds the methods can detect known ADE and so could potentially be used to detect unknown ADE.

  17. Amplitude Integrated Electroencephalography Compared With Conventional Video EEG for Neonatal Seizure Detection: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Rakshasbhuvankar, Abhijeet; Rao, Shripada; Palumbo, Linda; Ghosh, Soumya; Nagarajan, Lakshmi

    2017-08-01

    This diagnostic accuracy study compared the accuracy of seizure detection by amplitude-integrated electroencephalography with the criterion standard conventional video EEG in term and near-term infants at risk of seizures. Simultaneous recording of amplitude-integrated EEG (2-channel amplitude-integrated EEG with raw trace) and video EEG was done for 24 hours for each infant. Amplitude-integrated EEG was interpreted by a neonatologist; video EEG was interpreted by a neurologist independently. Thirty-five infants were included in the analysis. In the 7 infants with seizures on video EEG, there were 169 seizure episodes on video EEG, of which only 57 were identified by amplitude-integrated EEG. Amplitude-integrated EEG had a sensitivity of 33.7% for individual seizure detection. Amplitude-integrated EEG had an 86% sensitivity for detection of babies with seizures; however, it was nonspecific, in that 50% of infants with seizures detected by amplitude-integrated EEG did not have true seizures by video EEG. In conclusion, our study suggests that amplitude-integrated EEG is a poor screening tool for neonatal seizures.

  18. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub [Yonsei University, Department of Radiology, Wonju College of Medicine, Wonju (Korea, Republic of); You, Joshua H. [Center for Health, Wellness, Fitness, Prevention, and Healing Across the Life Span, Department of Physical Therapy, Graduate School of Rehabilitation Science, Yonsei University, Center for Movement Impairment Solutions, Wonju City (Korea, Republic of); Lee, Ji Yong [Yonsei University, Department of Neurology, Wonju College of Medicine, Wonju (Korea, Republic of); Whang, Kum [Yonsei University, Department of Neurosurgery, Wonju College of Medicine, Wonju (Korea, Republic of)

    2010-12-15

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P < 0.01. There was no significant statistical difference in the accuracy (91.79% vs. 93.23% in regional cerebral blood volume; 92.26% vs. 95.31% in regional cerebral blood flow; 89.17% vs. 92.71% in mean transit time; 89.76% vs. 92.19% in time to peak; P > 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  19. The occipital cortex in detection and categorisation abilities: an fMRI study in hemianopia

    International Nuclear Information System (INIS)

    Perez, C.; Coubard, O.; Cavezian, C.; Gout, O.; Chokron, S.; Peyrin, C.; Andersson, F.; Doucet, G.

    2011-01-01

    Complete text of publication follows: Previous studies have shown that the right and left hemispheres are predominant for detection and categorization tasks, respectively. This asymmetry appears to be instantiated at a processing stage as early as the occipital cortex. The present study was intended to assess the cerebral network responsible for natural scenes perception in hemianopic patients suffering from an occipital cortex lesion. One Left and one Right hemianopic patient (LH or RH; respectively right and left occipital damage) were compared with 14 healthy controls in detection and categorisation tasks of natural scenes. Both tasks were performed in a 1.5 T scanner to collect anatomical and functional data. In healthy controls, occipital activation was observed in the extra-striate areas of both hemispheres in the detection task but only of the left hemisphere in the categorization task. The LH (patient showed a bilateral occipital activation in both tasks. while, the RH patient showed unilateral right (intact) occipital activation in both tasks. These results highlight the importance of the perceptual task (detection vs. categorization) on the hemispheric asymmetry. They also suggest that different cortical reorganisations take place depending on the occipital lesion side

  20. A Feasibility Study on Timber Damage Detection Using Piezoceramic-Transducer-Enabled Active Sensing

    Directory of Open Access Journals (Sweden)

    Jicheng Zhang

    2018-05-01

    Full Text Available In recent years, piezoelectric-based transducers and technologies have made significant progress towards structural health monitoring and damage evaluation for various metal and concrete structures. Timber is still commonly used as a construction material in practical engineering; however, there is a lack of research on the health monitoring of timber-based structures using piezoelectric-based transducers and methods. This paper conducts a feasibility study on timber damage detection using surface-mounted piezoelectric patches, which enable the stress-wave-based active sensing approach. Typical damage modes in timber frame structures, such as surface cracks and holes, were investigated in this study. In the active sensing approach, one piezoceramic transducer is used as an actuator to generate stress waves, which propagate along the surface of the timber structure, and other piezoceramic transducers function as sensors to detect the propagating stress waves. Defects, such as a crack or a hole, induce additional attenuation to the propagating stress wave. Based on this attenuation, the proposed method can detect the defects using the wavelet-packet-based damage index, demonstrating its implementation potential for real-time timber damage detection.

  1. Optically Detected Magnetic Resonance and Thermal Activation Spectroscopy Study of Organic Semiconductors

    International Nuclear Information System (INIS)

    Chang-Hwan Kim

    2003-01-01

    Organic electronic materials are a new class of emerging materials. Organic light emitting devices (OLEDs) are the most promising candidates for future flat panel display technologies. The photophysical characterization is the basic research step one must follow to understand this new class of materials and devices. The light emission properties are closely related to the transport properties of these materials. The objective of this dissertation is to probe the relation between transport and photophysical properties of organic semiconductors. The transport characteristics were evaluated by using thermally stimulated current and thermally stimulated luminescence techniques. The photoluminescence detected magnetic resonance and photoluminescence quantum yield studies provide valuable photophysical information on this class of materials. OLEDs are already in the market. However, detailed studies on the degradation mechanisms are still lacking. Since both optically detected magnetic resonance and thermal activation spectroscopy probe long-lived defect-related states in organic semiconductors, the combined study generates new insight on the OLED operation and degradation mechanisms

  2. Optically Detected Magnetic Resonance and Thermal Activation Spectroscopy Study of Organic Semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Hwan [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    Organic electronic materials are a new class of emerging materials. Organic light emitting devices (OLEDs) are the most promising candidates for future flat panel display technologies. The photophysical characterization is the basic research step one must follow to understand this new class of materials and devices. The light emission properties are closely related to the transport properties of these materials. The objective of this dissertation is to probe the relation between transport and photophysical properties of organic semiconductors. The transport characteristics were evaluated by using thermally stimulated current and thermally stimulated luminescence techniques. The photoluminescence detected magnetic resonance and photoluminescence quantum yield studies provide valuable photophysical information on this class of materials. OLEDs are already in the market. However, detailed studies on the degradation mechanisms are still lacking. Since both optically detected magnetic resonance and thermal activation spectroscopy probe long-lived defect-related states in organic semiconductors, the combined study generates new insight on the OLED operation and degradation mechanisms.

  3. Can iridology detect susceptibility to cancer? A prospective case-controlled study.

    Science.gov (United States)

    Münstedt, Karsten; El-Safadi, Samer; Brück, Friedel; Zygmunt, Marek; Hackethal, Andreas; Tinneberg, Hans-Rudolf

    2005-06-01

    This prospective case-control study aimed to investigate the value of iridology as a diagnostic tool in detecting some common cancers. One hundred ten (110) subjects were enrolled in the study: 68 subjects had histologically proven cancers of the breast, ovary, uterus, prostate, or colorectum, and 42 were control subjects. All subjects were examined by an experienced practitioner of iridology, who was unaware of their gender or medical details. He was allowed to suggest up to five diagnoses for each subject and his results were then compared with each subject's medical diagnosis to determine the accuracy of iridology in detecting malignancy. Iridology identified the correct diagnosis in only 3 cases (sensitivity, 0.04). Iridology was of no value in diagnosing the cancers investigated in this study.

  4. Design study and comparative evaluation of JSFR failed fuel detection system

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, K.; Chikazawa, Y.; Ishikawa, N. [Japan Atomic Energy Agency JAEA, 4002 Narita, Oarai, Higashi-ibaraki-gun, Ibaraki 311-1393 (Japan); Kubo, S. [Japan Atomic Power Company JAPC (Japan); Okazaki, H.; Mito, M. [Mitsubishi FBR Systems, Inc. MFBR (Japan); Tozawa, K. [Fuji Electric Co., Ltd. (Japan); Hayashi, M. [MitsubishiElectric Corporation (Japan)

    2012-07-01

    A conceptual design study of an advanced sodium-cooled fast reactor JSFR has progressed in the 'Fast Reactor Cycle Technology Development (FaCT) 'project in Japan. JSFR has two failed fuel detection systems in the core. One is a failed fuel detection (FFD) system which continuously monitors a fission product from failed fuel subassembly. The other is a failed fuel detection and location (FFDL) system which locates when it receives signals from FFD. The FFD system consists of a FFD-DN which detects delayed neutron (DN) in sodium and a FFD-CG which detects fission products in the cover gas of the reactor vessel. In this study, requirements to the FFD-DN and the FFD-DN design to meet the requirements were investigated for the commercial and demonstration JSFR. In the commercial JSFR, a sampling type FFD which collects sodium from the reactor vessel by sampling lines for DN detectors was adopted. The performances have been investigated and confirmed by a fluid analysis in the reactor upper plenum. In the demonstration JSFR, the performance of DN detectors installed on the primary cold-leg piping has been confirmed. For the FFDL systems, experiences in the previous fast reactors and the R and D of FFDL system for JSFR were investigated. This study focuses on the Selector-Valve and the Tagging-Gas FFDL systems. Operation experiences of the Selector-valve FFDL system were accumulated in PFR and Phenix. Tagging-gas system experiences were accumulated in EBR-II and FFTF. The feasibility of both FFDL systems for JSFR was evaluated. (authors)

  5. Magnetic resonance (MR) colonography in the detection of colorectal lesions: a systematic review of prospective studies

    International Nuclear Information System (INIS)

    Zijta, Frank M.; Bipat, Shandra; Stoker, Jaap

    2010-01-01

    To determine the diagnostic accuracy of MR-colonography for the detection of colorectal lesions. A comprehensive literature search was performed for comparative MR-colonography studies, published between May 1997 and February 2009, using the MEDLINE, EMBASE and Cochrane databases. We included studies if MR-colonography findings were prospectively compared with conventional colonoscopy in (a)symptomatic patients. Two reviewers independently extracted study design characteristics and data for summarising sensitivity and specificity. Heterogeneity in findings between studies was tested using I 2 test statistics. Sensitivity and specificity estimates with 95% confidence intervals (CI) were calculated on per patient basis and summary sensitivity on per polyp basis, using bivariate and univariate statistical models. Thirty-seven studies were found to be potentially relevant and 13 fulfilled the inclusion criteria. The study population comprised 1,285 patients with a mean disease prevalence of 44% (range 22-63%). Sensitivity for the detection of CRC was 100%. Significant heterogeneity was found for overall per patient sensitivity and specificity. For polyps with a size of 10 mm or larger, per patient sensitivity and specificity estimates were 88% (95% CI 63-97%; I 2 = 37%) and 99% (95% CI 95-100%; I 2 = 60%). On a per polyp basis, polyps of 10 mm or larger were detected with a sensitivity of 84% (95% CI 66-94%; I 2 = 51%). The data were too heterogeneous for polyps smaller than 6 mm and 6-9 mm. MR-colonography can accurately detect colorectal polyps more than 10 mm in size. (orig.)

  6. A comparative study of the detectability of TMJ radiographic techniques for artificial mandibular condylar lesions

    International Nuclear Information System (INIS)

    Jeong, Hee Jeong; Jung, Yeon Hwa; Cho, Bong Hae

    1997-01-01

    The purpose of this study was to evaluate the detectability of various radiographic techniques for mandibular condylar lesions. Erosive lesion, osteophyte and flattening were formed on the artificial mandibular condyle, and panoramic, transcranial, transorbital radiography, lateral and frontal tomography were taken. The results were as follows; 1. The detectability for erosive lesions was superior in the order of frontal tomography (96%), lateral tomography (78%), transorbital (59%), transcranial (56%) and panoramic (48%) radiography. 2. The location of erosive lesion that showed the highest detectability was the medial third in panoramic, the lateral third in transcranial, the central portion of anteroposterior direction in transorbital, the central portion of mediolateral direction and the posterior third in lateral tomography. Frontal tomography disclosed all erosive lesions except one anterolateral lesion. 3. The detectability of osteophyte was 100% in lateral tomography, 78% in transcranial and 56% in panoramic radiography. 4. For flattening, lateral tomography showed the flattened condyle, but both panoramic and transcranial views showed only decreased bone density without the change of condylar shape.

  7. Neural Bases of Unconscious Error Detection in a Chinese Anagram Solution Task: Evidence from ERP Study.

    Directory of Open Access Journals (Sweden)

    Hua-Zhan Yin

    Full Text Available In everyday life, error monitoring and processing are important for improving ongoing performance in response to a changing environment. However, detecting an error is not always a conscious process. The temporal activation patterns of brain areas related to cognitive control in the absence of conscious awareness of an error remain unknown. In the present study, event-related potentials (ERPs in the brain were used to explore the neural bases of unconscious error detection when subjects solved a Chinese anagram task. Our ERP data showed that the unconscious error detection (UED response elicited a more negative ERP component (N2 than did no error (NE and detect error (DE responses in the 300-400-ms time window, and the DE elicited a greater late positive component (LPC than did the UED and NE in the 900-1200-ms time window after the onset of the anagram stimuli. Taken together with the results of dipole source analysis, the N2 (anterior cingulate cortex might reflect unconscious/automatic conflict monitoring, and the LPC (superior/medial frontal gyrus might reflect conscious error recognition.

  8. Simulation study of melanoma detection in human skin tissues by laser-generated surface acoustic waves.

    Science.gov (United States)

    Chen, Kun; Fu, Xing; Dorantes-Gonzalez, Dante J; Lu, Zimo; Li, Tingting; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2014-01-01

    Air pollution has been correlated to an increasing number of cases of human skin diseases in recent years. However, the investigation of human skin tissues has received only limited attention, to the point that there are not yet satisfactory modern detection technologies to accurately, noninvasively, and rapidly diagnose human skin at epidermis and dermis levels. In order to detect and analyze severe skin diseases such as melanoma, a finite element method (FEM) simulation study of the application of the laser-generated surface acoustic wave (LSAW) technique is developed. A three-layer human skin model is built, where LSAW’s are generated and propagated, and their effects in the skin medium with melanoma are analyzed. Frequency domain analysis is used as a main tool to investigate such issues as minimum detectable size of melanoma, filtering spectra from noise and from computational irregularities, as well as on how the FEM model meshing size and computational capabilities influence the accuracy of the results. Based on the aforementioned aspects, the analysis of the signals under the scrutiny of the phase velocity dispersion curve is verified to be a reliable, a sensitive, and a promising approach for detecting and characterizing melanoma in human skin.

  9. UAS imaging for automated crop lodging detection: a case study over an experimental maize field

    Science.gov (United States)

    Chu, Tianxing; Starek, Michael J.; Brewer, Michael J.; Masiane, Tiisetso; Murray, Seth C.

    2017-05-01

    Lodging has been recognized as one of the major destructive factors for crop quality and yield, particularly in corn. A variety of contributing causes, e.g. disease and/or pest, weather conditions, excessive nitrogen, and high plant density, may lead to lodging before harvesting season. Traditional lodging detection strategies mainly rely on ground data collection, which is insufficient in efficiency and accuracy. To address this problem, this research focuses on the use of unmanned aircraft systems (UAS) for automated detection of crop lodging. The study was conducted over an experimental corn field at the Texas A and M AgriLife Research and Extension Center at Corpus Christi, Texas, during the growing season of 2016. Nadir-view images of the corn field were taken by small UAS platforms equipped with consumer grade RGB and NIR cameras on a per week basis, enabling a timely observation of the plant growth. 3D structural information of the plants was reconstructed using structure-from-motion photogrammetry. The structural information was then applied to calculate crop height, and rates of growth. A lodging index for detecting corn lodging was proposed afterwards. Ground truth data of lodging was collected on a per row basis and used for fair assessment and tuning of the detection algorithm. Results show the UAS-measured height correlates well with the ground-measured height. More importantly, the lodging index can effectively reflect severity of corn lodging and yield after harvesting.

  10. A primitive study on unsupervised anomaly detection with an autoencoder in emergency head CT volumes

    Science.gov (United States)

    Sato, Daisuke; Hanaoka, Shouhei; Nomura, Yukihiro; Takenaga, Tomomi; Miki, Soichiro; Yoshikawa, Takeharu; Hayashi, Naoto; Abe, Osamu

    2018-02-01

    Purpose: The target disorders of emergency head CT are wide-ranging. Therefore, people working in an emergency department desire a computer-aided detection system for general disorders. In this study, we proposed an unsupervised anomaly detection method in emergency head CT using an autoencoder and evaluated the anomaly detection performance of our method in emergency head CT. Methods: We used a 3D convolutional autoencoder (3D-CAE), which contains 11 layers in the convolution block and 6 layers in the deconvolution block. In the training phase, we trained the 3D-CAE using 10,000 3D patches extracted from 50 normal cases. In the test phase, we calculated abnormalities of each voxel in 38 emergency head CT volumes (22 abnormal cases and 16 normal cases) for evaluation and evaluated the likelihood of lesion existence. Results: Our method achieved a sensitivity of 68% and a specificity of 88%, with an area under the curve of the receiver operating characteristic curve of 0.87. It shows that this method has a moderate accuracy to distinguish normal CT cases to abnormal ones. Conclusion: Our method has potentialities for anomaly detection in emergency head CT.

  11. Simulation study of melanoma detection in human skin tissues by laser-generated surface acoustic waves

    Science.gov (United States)

    Chen, Kun; Fu, Xing; Dorantes-Gonzalez, Dante J.; Lu, Zimo; Li, Tingting; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2014-07-01

    Air pollution has been correlated to an increasing number of cases of human skin diseases in recent years. However, the investigation of human skin tissues has received only limited attention, to the point that there are not yet satisfactory modern detection technologies to accurately, noninvasively, and rapidly diagnose human skin at epidermis and dermis levels. In order to detect and analyze severe skin diseases such as melanoma, a finite element method (FEM) simulation study of the application of the laser-generated surface acoustic wave (LSAW) technique is developed. A three-layer human skin model is built, where LSAW's are generated and propagated, and their effects in the skin medium with melanoma are analyzed. Frequency domain analysis is used as a main tool to investigate such issues as minimum detectable size of melanoma, filtering spectra from noise and from computational irregularities, as well as on how the FEM model meshing size and computational capabilities influence the accuracy of the results. Based on the aforementioned aspects, the analysis of the signals under the scrutiny of the phase velocity dispersion curve is verified to be a reliable, a sensitive, and a promising approach for detecting and characterizing melanoma in human skin.

  12. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study.

    Science.gov (United States)

    Proescholdt, Martin A; Faltermeier, Rupert; Bele, Sylvia; Brawanski, Alexander

    2017-01-01

    Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca), correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp). In this study we compared the results of the sca with the pressure reactivity index (PRx), an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc). The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data.

  13. Detection of Impaired Cerebral Autoregulation Using Selected Correlation Analysis: A Validation Study

    Directory of Open Access Journals (Sweden)

    Martin A. Proescholdt

    2017-01-01

    Full Text Available Multimodal brain monitoring has been utilized to optimize treatment of patients with critical neurological diseases. However, the amount of data requires an integrative tool set to unmask pathological events in a timely fashion. Recently we have introduced a mathematical model allowing the simulation of pathophysiological conditions such as reduced intracranial compliance and impaired autoregulation. Utilizing a mathematical tool set called selected correlation analysis (sca, correlation patterns, which indicate impaired autoregulation, can be detected in patient data sets (scp. In this study we compared the results of the sca with the pressure reactivity index (PRx, an established marker for impaired autoregulation. Mean PRx values were significantly higher in time segments identified as scp compared to segments showing no selected correlations (nsc. The sca based approach predicted cerebral autoregulation failure with a sensitivity of 78.8% and a specificity of 62.6%. Autoregulation failure, as detected by the results of both analysis methods, was significantly correlated with poor outcome. Sca of brain monitoring data detects impaired autoregulation with high sensitivity and sufficient specificity. Since the sca approach allows the simultaneous detection of both major pathological conditions, disturbed autoregulation and reduced compliance, it may become a useful analysis tool for brain multimodal monitoring data.

  14. A Pilot Study of Pedestrians with Visual Impairments Detecting Traffic Gaps and Surges Containing Hybrid Vehicles.

    Science.gov (United States)

    Emerson, Robert Wall; Naghshineh, Koorosh; Hapeman, Julie; Wiener, William

    2011-03-01

    The increasing number of hybrid and quiet internal combustion engine vehicles may impact the travel abilities of pedestrians who are blind. Pedestrians who rely on auditory cues for structuring their travel may face challenges in making crossing decisions in the presence of quiet vehicles. This article describes results of initial studies looking at the crossing decisions of pedestrians who are blind at an uncontrolled crossing (no traffic control) and a light controlled intersection. The presence of hybrid vehicles was a factor in each situation. At the uncontrolled crossing, Toyota hybrids were most difficult to detect but crossing decisions were made more often in small gaps ended by a Honda hybrid. These effects were seen only at speed under 20 mph. At the light controlled intersection, parallel surges of traffic were most difficult to detect when made up only of a Ford Escape hybrid. Results suggest that more controlled studies of vehicle characteristics impacting crossing decisions of pedestrians who are blind are warranted.

  15. Quench Detection and Magnet Protection Study for MFTF. LLL final review

    International Nuclear Information System (INIS)

    1979-06-01

    The results of a Quench Detection and Magnet Protection Study for MFTF are summarized. The study was directed toward establishing requirements and guidelines for the electronic package used to protect the MFTF superconducting magnets. Two quench detection schemes were analyzed in detail, both of which require a programmable quench detector. Hardware and software recommendations for the quench detector were presented as well as criteria for dumping the magnet energy in the event of a quench. Overall magnet protection requirements were outlined in a detailed Failure Mode Effects and Criticality analysis, (FMECA). Hardware and software packages compatible with the FMECA were recommended, with the hardware consisting of flexible, dedicated intelligent modules specifically designed for magnet protection

  16. Ion generation and CPC detection efficiency studies in sub 3-nm size range

    Energy Technology Data Exchange (ETDEWEB)

    Kangasluoma, J.; Junninen, H.; Sipilae, M.; Kulmala, M.; Petaejae, T. [Department of Physics, P.O. Box 64, 00014, University of Helsinki, Helsinki (Finland); Lehtipalo, K. [Department of Physics, P.O. Box 64, 00014, University of Helsinki, Helsinki (Finland); Airmodus Ltd., Finland, Gustaf Haellstroemin katu 2 A, 00560 Helsinki (Finland); Mikkilae, J.; Vanhanen, J. [Airmodus Ltd., Finland, Gustaf Haellstroemin katu 2 A, 00560 Helsinki (Finland); Attoui, M. [University Paris Est Creteil, University Paris-Diderot, LISA, UMR CNRS 7583 (France); Worsnop, D. [Department of Physics, P.O. Box 64, 00014, University of Helsinki, Helsinki (Finland) and Aerodyne Research Inc., Billerica, MA (United States)

    2013-05-24

    We studied the chemical composition of commonly used condensation particle counter calibration ions with a mass spectrometer and found that in our calibration setup the negatively charged ammonium sulphate, sodium chloride and tungsten oxide are the least contaminated whereas silver on both positive and negative and the three mentioned earlier in positive mode are contaminated with organics. We report cut-off diameters for Airmodus Particle Size Magnifier (PSM) 1.1, 1.3, 1.4, 1.6 and 1.6-1.8 nm for negative sodium chloride, ammonium sulphate, tungsten oxide, silver and positive organics, respectively. To study the effect of sample relative humidity on detection efficiency of the PSM we used different humidities in the differential mobility analyzer sheath flow and found that with increasing relative humidity also the detection efficiency of the PSM increases.

  17. Ion generation and CPC detection efficiency studies in sub 3-nm size range

    International Nuclear Information System (INIS)

    Kangasluoma, J.; Junninen, H.; Sipilä, M.; Kulmala, M.; Petäjä, T.; Lehtipalo, K.; Mikkilä, J.; Vanhanen, J.; Attoui, M.; Worsnop, D.

    2013-01-01

    We studied the chemical composition of commonly used condensation particle counter calibration ions with a mass spectrometer and found that in our calibration setup the negatively charged ammonium sulphate, sodium chloride and tungsten oxide are the least contaminated whereas silver on both positive and negative and the three mentioned earlier in positive mode are contaminated with organics. We report cut-off diameters for Airmodus Particle Size Magnifier (PSM) 1.1, 1.3, 1.4, 1.6 and 1.6-1.8 nm for negative sodium chloride, ammonium sulphate, tungsten oxide, silver and positive organics, respectively. To study the effect of sample relative humidity on detection efficiency of the PSM we used different humidities in the differential mobility analyzer sheath flow and found that with increasing relative humidity also the detection efficiency of the PSM increases.

  18. Modeling and Simulation Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

    Energy Technology Data Exchange (ETDEWEB)

    Ely, James H.; Siciliano, Edward R.; Swinhoe, Martyn T.; Lintereur, Azaree T.

    2013-01-01

    This report details the results of the modeling and simulation work accomplished for the ‘Neutron Detection without Helium-3’ project during the 2011 and 2012 fiscal years. The primary focus of the project is to investigate commercially available technologies that might be used in safeguards applications in the relatively near term. Other technologies that are being developed may be more applicable in the future, but are outside the scope of this study.

  19. Dental Hygiene Faculty Calibration Using Two Accepted Standards for Calculus Detection: A Pilot Study.

    Science.gov (United States)

    Santiago, Lisa J; Freudenthal, Jacqueline J; Peterson, Teri; Bowen, Denise M

    2016-08-01

    Faculty calibration studies for calculus detection use two different standards for examiner evaluation, yet the only therapeutic modality that can be used for nonsurgical periodontal treatment is scaling/root debridement or planing. In this study, a pretest-posttest design was used to assess the feasibility of faculty calibration for calculus detection using two accepted standards: that established by the Central Regional Dental Testing Service, Inc. (CRDTS; readily detectible calculus) and the gold standard for scaling/root debridement (root roughness). Four clinical dental hygiene faculty members out of five possible participants at Halifax Community College agreed to participate. The participants explored calculus on the 16 assigned teeth (64 surfaces) of four patients. Calculus detection scores were calculated before and after training. Kappa averages using CRDTS criteria were 0.561 at pretest and 0.631 at posttest. Kappa scores using the scaling/root debridement or planing standard were 0.152 at pretest and 0.271 at posttest. The scores indicated improvement from moderate (Kappa=0.41-0.60) to substantial agreement (Kappa=0.61-0.80) following training using the CRDTS standard. Although this result differed qualitatively and Kappas were significantly different from 0, the differences for pre- to post-Kappas for patient-rater dyads using CRDTS were not statistically significant (p=0.778). There was no difference (p=0.913) in Kappa scores pre- to post-training using the scaling/root debridement standard. Despite the small number of participants in this study, the results indicated that training to improve interrater reliability to substantial agreement was feasible using the CRDTS standard but not using the gold standard. The difference may have been due to greater difficulty in attaining agreement regarding root roughness. Future studies should include multiple training sessions with patients using the same standard for scaling/root debridement used for

  20. X-rays detection system to obtain digital imagines for the study of artworks

    International Nuclear Information System (INIS)

    Bolanos, L.; Cabal, A. E.; Diaz, A.; Ramello, L.; Prino, F.; Giubellino, P.; Marzari-Chiesa, A.; Grybos, P.; Maj, P.; Gambaccini, M.; Petrucci, F.; Albertin, F.

    2008-01-01

    X-ray radiography plays an important role in the study of artworks. It particularly provides information on the origin, authenticity, painting technique, material conditions and its conservation history. This article describes a system based on semiconductor microstrip detector for obtaining X-ray images using the k-edge logarithmic substraction technique. The system has been characterized and the first images of its application for pigment detection are shown. (Author)

  1. Detection of the corrosion in reinforced concrete with GPR: the case study of the Park Guell

    Science.gov (United States)

    Sossa, Viviana; Perez-Gracia, Vega; Gonzalez-Drigo, Ramon; Caselles, Oriol; Clapes, Jaume

    2017-04-01

    Detection of corrosion is important in cultural heritage assessment. Many structures contain metallic targets embedded in masonry or mortar, and corrosion cab cause important damage. However, detection using non-destructive methods is difficult and highly localized, providing in most cases incomplete results. In order to obtain a more extended analysis, GPR was applied and evaluated to detect damage as consequence of corrosion. This technique is a non-destructive method that covers a large area of study while other methods are constrained to a small areas or specific points. Therefore, some controlled laboratory tests were designed to determine possible differences in radargrams obtained in the case of corroded and non-corroded targets. These analysis allowed to observe that the corrosion seems to increase the attenuation of the radar signal, being difficult to detect targets near the damaged bars. The results were applied to study the mosaic roofs in the Park Guell, in Barcelona. This park is one of the most important Modernista (Art Noveau) complex in Barcelona. It is characterized by structures with roofs and banks with tessellation. Some of these structures are most likely supported by metal elements, and seepage cause important damage observed over the tessellation. The objective of the study was to define the possible existence of those metallic targets, determining their location. And, in the case of existence of metallic elements, defining which are the zones more affected by corrosion. The results demonstrates the existence of metallic supports in many parts, as well as some defined areas that could be damaged. Acknowledgement: This work has been partially funded by the Spanish Government and by the European Commission with FEDER funds, through the research projects CGL2011-23621 and CGL2015-65913-P. The study is also a contribution to the EU funded COST Action TU1208, "Civil Engineering Applications of Ground Penetrating Radar", to the working group 2.2.

  2. Study of a high surface gas triode for detecting atomic or nuclear particles

    International Nuclear Information System (INIS)

    Lansiart, A.

    1967-06-01

    A triode filled with xenon at atmospheric pressure can be used as an X-ray detector since it produces an appreciable amount of light per quantum absorbed. Various methods are described for studying and reducing the deadtime after the passage of a spark. This detector can be used in medicine for the detection of tumours and also for the rapid recording of diffraction diagrams. (author) [fr

  3. Neuropathic pain and use of PainDETECT in patients with fibromyalgia: a cohort study

    OpenAIRE

    Gauffin, Jarno; Hankama, Tiina; Kautiainen, Hannu; Hannonen, Pekka; Haanp??, Maija

    2013-01-01

    Abstract Backround Fibromyalgia has a plethorae of symptoms, which can be confusing and even misleading. Accurate evaluation is necessary when patients with fibromyalgia are treated. Different types of instruments are available for the clinicians to supplement evaluation. Our objective was to study the applicability of the PainDETECT instrument to screen neuropathic pain in patients with fibromyalgia. Methods 158 patients with primary fibromyalgia underwent a neurological examination includin...

  4. Caenorhabditis elegans Egg-Laying Detection and Behavior Study Using Image Analysis

    Directory of Open Access Journals (Sweden)

    Palm Megan

    2005-01-01

    Full Text Available Egg laying is an important phase of the life cycle of the nematode Caenorhabditis elegans (C. elegans. Previous studies examined egg-laying events manually. This paper presents a method for automatic detection of egg-laying onset using deformable template matching and other morphological image analysis techniques. Some behavioral changes surrounding egg-laying events are also studied. The results demonstrate that the computer vision tools and the algorithm developed here can be effectively used to study C. elegans egg-laying behaviors. The algorithm developed is an essential part of a machine-vision system for C. elegans tracking and behavioral analysis.

  5. Study of cartridge rupture detection installations; Contribution a l'etude des installations de detection de ruptures de gaine

    Energy Technology Data Exchange (ETDEWEB)

    Graftieaux, J; Douet, P; Roguin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    Very numerous physical or technological parameters are involved in the preparation of projects for can rupture detection installations. These parameters are connected essentially with the design of the reactor, the detector used, the disposition of the pneumatic circuits, the type of fuel and the safety required. The present report analyses the main problems arising and their mutual compatibilities; it defines a certain number of ideas which had up till now been accepted implicitly in the design. (authors) [French] De tres nombreux parametres physiques ou technologiques interviennent dans l'etablissement du projet d'une installation de detection de ruptures de gaines. Ces parametres decoulent essentiellement de la conception de la pile, du detecteur utilise, de l'organisation des circuits pneumatiques, du type du combustible et de la securite souhaitee. Le present document analyse les principaux problemes qui se posent ainsi que leurs compatibilites reciproques et precise un certain nombre de notions jusqu'alors admises implicitement lors de l'etablissement des projets. (auteurs)

  6. Volatile Organic Compound (VOC) Analysis For Disease Detection: Proof Of Principle For Field Studies Detecting Paratuberculosis And Brucellosis

    Science.gov (United States)

    Knobloch, Henri; Köhler, Heike; Nicola, Commander; Reinhold, Petra; Turner, Claire; Chambers, Mark

    2009-05-01

    A proof of concept investigation was performed to demonstrate that two independent infectious diseases of cattle result in different patterns of volatile organic compounds (VOC) in the headspace of serum samples detectable using an electronic nose (e-nose). A total of 117 sera from cattle naturally infected with Mycobacterium avium subsp. paratuberculosis (paraTB, n = 43) or Brucella sp. (n = 26) and sera from corresponding control animals (n = 48) were randomly and analysed blind to infection status using a ST214 e-nose (Scensive Ltd, Leeds, UK). Samples were collected under non-standardised conditions on different farms from the UK (brucellosis) and Germany (paraTB). The e-nose could differentiate the sera from brucellosis infected, paraTB infected and healthy animals at the population level, but the technology used was not suitable for determination of the disease status of individual animals. Nevertheless, the data indicate that there are differences in the sensor responses depending on the disease status, and therefore, it shows the potential of VOC analysis from serum headspace samples for disease detection.

  7. Lie detection based on nonverbal expressions - study of the Czech Republic Police employees

    Directory of Open Access Journals (Sweden)

    Hedvika Boukalová

    2014-12-01

    Full Text Available Lie detection based on nonverbal behavior is not a standard method, it is an intuitive process, applied by lay persons, but also professionals. Some of the major sources (e.g. widespread Interrogation Manual by F. Inbau et al., 2004 offer clear recommendations about the nonverbal behavior of liars to investigators of serious crime. These findings are not supported by the research, moreover they can lead to lowering the ability to detect lie (Blair, Kooi 2004. Another topic is mapping the skills of professionals (police officers, members of the secret services and non-specialists to detect lies by nonverbal signs. Across the studies (with few exceptions a low performance in the task of detecting lies by nonverbal expressions (Ekman P., 1996; Vrij, 2004 and others is found. The levels of success are usually around the level of chance. The potential reasons for such results are analyzed (e.g. Blair, Kooi, 2004. However a group of psychologists led by P. Ekman and M. O'Sullivan (O'Sullivan, 2007 managed to find in their years lasting research a group of people whose ability to detect lies is well above the population average. This group is diverse in terms of age, interests and professions, all of them come from the USA. There were certain common features found in this group and also a focus on similar phenomena in the detection of lying. The main goal and research question is to find out: what is the success rate of differentiation between lies and truths in this specific professional group of Czech population, is it the same or different from the results reported in the context of available resources. The research will focus on the ability of respondents to determine the truth or deceit on the basis of non-verbal and paraverbal expressions of observed subjects, with focus on specific professional groups - mainly police workers. We assume, that the police officers are frequently in the contact with people, who are not willing to reveal critical

  8. Calculus detection calibration among dental hygiene faculty members utilizing dental endoscopy: a pilot study.

    Science.gov (United States)

    Partido, Brian B; Jones, Archie A; English, Dana L; Nguyen, Carol A; Jacks, Mary E

    2015-02-01

    Dental and dental hygiene faculty members often do not provide consistent instruction in the clinical environment, especially in tasks requiring clinical judgment. From previous efforts to calibrate faculty members in calculus detection using typodonts, researchers have suggested using human subjects and emerging technology to improve consistency in clinical instruction. The purpose of this pilot study was to determine if a dental endoscopy-assisted training program would improve intra- and interrater reliability of dental hygiene faculty members in calculus detection. Training included an ODU 11/12 explorer, typodonts, and dental endoscopy. A convenience sample of six participants was recruited from the dental hygiene faculty at a California community college, and a two-group randomized experimental design was utilized. Intra- and interrater reliability was measured before and after calibration training. Pretest and posttest Kappa averages of all participants were compared using repeated measures (split-plot) ANOVA to determine the effectiveness of the calibration training on intra- and interrater reliability. The results showed that both kinds of reliability significantly improved for all participants and the training group improved significantly in interrater reliability from pretest to posttest. Calibration training was beneficial to these dental hygiene faculty members, especially those beginning with less than full agreement. This study suggests that calculus detection calibration training utilizing dental endoscopy can effectively improve interrater reliability of dental and dental hygiene clinical educators. Future studies should include human subjects, involve more participants at multiple locations, and determine whether improved rater reliability can be sustained over time.

  9. A study of the transferability of influenza case detection systems between two large healthcare systems.

    Science.gov (United States)

    Ye, Ye; Wagner, Michael M; Cooper, Gregory F; Ferraro, Jeffrey P; Su, Howard; Gesteland, Per H; Haug, Peter J; Millett, Nicholas E; Aronis, John M; Nowalk, Andrew J; Ruiz, Victor M; López Pineda, Arturo; Shi, Lingyun; Van Bree, Rudy; Ginter, Thomas; Tsui, Fuchiang

    2017-01-01

    This study evaluates the accuracy and transferability of Bayesian case detection systems (BCD) that use clinical notes from emergency department (ED) to detect influenza cases. A BCD uses natural language processing (NLP) to infer the presence or absence of clinical findings from ED notes, which are fed into a Bayesain network classifier (BN) to infer patients' diagnoses. We developed BCDs at the University of Pittsburgh Medical Center (BCDUPMC) and Intermountain Healthcare in Utah (BCDIH). At each site, we manually built a rule-based NLP and trained a Bayesain network classifier from over 40,000 ED encounters between Jan. 2008 and May. 2010 using feature selection, machine learning, and expert debiasing approach. Transferability of a BCD in this study may be impacted by seven factors: development (source) institution, development parser, application (target) institution, application parser, NLP transfer, BN transfer, and classification task. We employed an ANOVA analysis to study their impacts on BCD performance. Both BCDs discriminated well between influenza and non-influenza on local test cases (AUCs > 0.92). When tested for transferability using the other institution's cases, BCDUPMC discriminations declined minimally (AUC decreased from 0.95 to 0.94, pdetection performance in two large healthcare systems in two geographically separated regions, providing evidentiary support for the use of automated case detection from routinely collected electronic clinical notes in national influenza surveillance. The transferability could be improved by training Bayesian network classifier locally and increasing the accuracy of the NLP parser.

  10. Improving early detection initiatives: a qualitative study exploring perspectives of older people and professionals.

    Science.gov (United States)

    Lette, Manon; Stoop, Annerieke; Lemmens, Lidwien C; Buist, Yvette; Baan, Caroline A; de Bruin, Simone R

    2017-06-23

    A wide range of initiatives on early detection and intervention have been developed to proactively identify problems related to health and wellbeing in (frail) older people, with the aim of supporting them to live independently for as long as possible. Nevertheless, it remains unclear what the best way is to design such initiatives and how older people's needs and preferences can be best addressed. This study aimed to address this gap in the literature by exploring: 1) older people's perspectives on health and living environment in relation to living independently at home; 2) older people's needs and preferences in relation to initiating and receiving care and support; and 3) professionals' views on what would be necessary to enable the alignment of early detection initiatives with older people's own needs and preferences. In this qualitative study, we conducted semi-structured interviews with 36 older people and 19 professionals in proactive elderly care. Data were analysed using the framework analysis method. From the interviews with older people important themes in relation to health and living environment emerged, such as maintaining independence, appropriate housing, social relationships, a supporting network and a sense of purpose and autonomy. Older people preferred to remain self-sufficient, and they would rather not ask for help for psychological or social problems. However, the interviews also highlighted that they were not always able or willing to anticipate future needs, which can hinder early detection or early intervention. At the same time, professionals indicated that older people tend to over-estimate their self-reliance and therefore advocated for early detection and intervention, including social and psychological issues. Older people have a broad range of needs in different domains of life. Discrepancies exist between older people and professionals with regard to their views on timing and scope of early detection initiatives. This study aimed

  11. Self administered cognitive screening test (TYM) for detection of Alzheimer’s disease: cross sectional study

    Science.gov (United States)

    Pengas, George; Dawson, Kate; Clatworthy, Philip

    2009-01-01

    Objective To evaluate a cognitive test, the TYM (“test your memory”), in the detection of Alzheimer’s disease. Design Cross sectional study. Setting Outpatient departments in three hospitals, including a memory clinic. Participants 540 control participants aged 18-95 and 139 patients attending a memory clinic with dementia/amnestic mild cognitive impairment. Intervention Cognitive test designed to use minimal operator time and to be suitable for non-specialist use. Main outcome measures Performance of normal controls on the TYM. Performance of patients with Alzheimer’s disease on the TYM compared with age matched controls. Validation of the TYM with two standard tests (the mini-mental state examination (MMSE) and the Addenbrooke’s cognitive examination-revised (ACE-R)). Sensitivity and specificity of the TYM in the detection of Alzheimer’s disease. Results Control participants completed the TYM with an average score of 47/50. Patients with Alzheimer’s disease scored an average of 33/50. The TYM score shows excellent correlation with the two standard tests. A score of ≤42/50 had a sensitivity of 93% and specificity of 86% in the diagnosis of Alzheimer’s disease. The TYM was more sensitive in detection of Alzheimer’s disease than the mini-mental examination, detecting 93% of patients compared with 52% for the mini-mental state exxamination. The negative and positive predictive values of the TYM with the cut off of ≤42 were 99% and 42% with a prevalence of Alzheimer’s disease of 10%. Thirty one patients with non-Alzheimer dementias scored an average of 39/50. Conclusions The TYM can be completed quickly and accurately by normal controls. It is a powerful and valid screening test for the detection of Alzheimer’s disease. PMID:19509424

  12. Visual acuity measures do not reliably detect childhood refractive error--an epidemiological study.

    Directory of Open Access Journals (Sweden)

    Lisa O'Donoghue

    Full Text Available PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

  13. Challenges in detecting HIV persistence during potentially curative interventions: a study of the Berlin patient.

    Directory of Open Access Journals (Sweden)

    Steven A Yukl

    Full Text Available There is intense interest in developing curative interventions for HIV. How such a cure will be quantified and defined is not known. We applied a series of measurements of HIV persistence to the study of an HIV-infected adult who has exhibited evidence of cure after allogeneic hematopoietic stem cell transplant from a homozygous CCR5Δ32 donor. Samples from blood, spinal fluid, lymph node, and gut were analyzed in multiple laboratories using different approaches. No HIV DNA or RNA was detected in peripheral blood mononuclear cells (PBMC, spinal fluid, lymph node, or terminal ileum, and no replication-competent virus could be cultured from PBMCs. However, HIV RNA was detected in plasma (2 laboratories and HIV DNA was detected in the rectum (1 laboratory at levels considerably lower than those expected in ART-suppressed patients. It was not possible to obtain sequence data from plasma or gut, while an X4 sequence from PBMC did not match the pre-transplant sequence. HIV antibody levels were readily detectable but declined over time; T cell responses were largely absent. The occasional, low-level PCR signals raise the possibility that some HIV nucleic acid might persist, although they could also be false positives. Since HIV levels in well-treated individuals are near the limits of detection of current assays, more sensitive assays need to be developed and validated. The absence of recrudescent HIV replication and waning HIV-specific immune responses five years after withdrawal of treatment provide proof of a clinical cure.

  14. Fiber optic fluorescence detection of low-level porphyrin concentrations in preclinical and clinical studies

    Science.gov (United States)

    Mang, Thomas S.; McGinnis, Carolyn; Khan, S.

    1990-07-01

    A significant clinical problem in the local treatment of cutaneous metastases of breast cancer (by any modality--surgery, radiation therapy or photodynainic therapy) is the fact that the disease almost always extends beyond the boundary of visible lesions in the form of microscopic deposits. These deposits may be distant from the site of visible disease but are often in close proximity to it and are manifested sooner or later by the development of recurrent lesions at the border of the treated area, thus the "marginal miss" in radiation therapy, the "rim recurrence" in photodynamic therapy, and the "incisional recurrence" following surgical excision. More intelligent use of these treatment modalities demands the ability to detect microscopic deposits of tumor cells using non-invasive methodology. In vivo fluorescence measurements have been made possible by the development of an extremely sensitive fiber optic in vivo fluorescence photometer. The instrument has been used to verify that fluorescence correlated with injected porphyrin levels in various tissues. The delivery of light to excite and detect background fluorescence as well as photosensitizer fluorescence in tissues has been accomplished using two HeNe lasers emitting at 632.8 nm and 612 nm delivered through a single quartz fiber optic. Chopping at different frequencies, contributions of fluorescence may be separated. Fluorescence is picked up via a 400 micron quartz fiber optic positioned appropriately near the target tissue. Validation of these levels was made by extraction of the drug from the tissues with resultant quantitation. Recently, an extensive study was undertaken to determine if fluorescence could be used for the detection of occult, clinically non-palpable metastases in the lymph node of rats. This unique model allowed for the detection of micrometastases in lymph nodes using very low injected doses of the photosensitizer Photofrin II. Data obtained revealed the ability to detect on the order

  15. A study of the transferability of influenza case detection systems between two large healthcare systems.

    Directory of Open Access Journals (Sweden)

    Ye Ye

    Full Text Available This study evaluates the accuracy and transferability of Bayesian case detection systems (BCD that use clinical notes from emergency department (ED to detect influenza cases.A BCD uses natural language processing (NLP to infer the presence or absence of clinical findings from ED notes, which are fed into a Bayesain network classifier (BN to infer patients' diagnoses. We developed BCDs at the University of Pittsburgh Medical Center (BCDUPMC and Intermountain Healthcare in Utah (BCDIH. At each site, we manually built a rule-based NLP and trained a Bayesain network classifier from over 40,000 ED encounters between Jan. 2008 and May. 2010 using feature selection, machine learning, and expert debiasing approach. Transferability of a BCD in this study may be impacted by seven factors: development (source institution, development parser, application (target institution, application parser, NLP transfer, BN transfer, and classification task. We employed an ANOVA analysis to study their impacts on BCD performance.Both BCDs discriminated well between influenza and non-influenza on local test cases (AUCs > 0.92. When tested for transferability using the other institution's cases, BCDUPMC discriminations declined minimally (AUC decreased from 0.95 to 0.94, p<0.01, and BCDIH discriminations declined more (from 0.93 to 0.87, p<0.0001. We attributed the BCDIH decline to the lower recall of the IH parser on UPMC notes. The ANOVA analysis showed five significant factors: development parser, application institution, application parser, BN transfer, and classification task.We demonstrated high influenza case detection performance in two large healthcare systems in two geographically separated regions, providing evidentiary support for the use of automated case detection from routinely collected electronic clinical notes in national influenza surveillance. The transferability could be improved by training Bayesian network classifier locally and increasing the

  16. First detections of nebula with the Fermi-Large Area Telescope and study of their pulsars

    International Nuclear Information System (INIS)

    Grondin, M.H.

    2010-07-01

    The Fermi Gamma-ray Space Telescope was launched on 2008 June 11, carrying the Large Area Telescope (LAT), sensitive to gamma-rays in the 20 MeV - 300 GeV energy range. The Crab Nebula had been detected and studied in the 70 MeV - 30 GeV band using the CGRO-EGRET experiment, but no pulsar wind nebula (PWN) had ever been firmly identified in the high energy gamma-ray domain. PWNe are powered by the constant injection of a relativistic wind of electrons and positrons from their central pulsars. These charged particles are accelerated at the shock front forming the PWN and emit photons which can be observed along the entire electromagnetic spectrum, including the high energy gamma-ray domain. Data provided by the Fermi-LAT during the first two years of the mission have allowed the detection and the identification of three PWNe and their associated pulsars (Crab Nebula, Vela X and MSH 15-52) as well as the PWN HESS J1825-137 discovered by ground-based experiments sensitive to very high energy gamma-rays. Results of temporal, spectral and morphological analyses of the pulsar/PWN systems detected by Fermi- LAT, as well as results of systematic studies performed first around every gamma-ray pulsar detected by the LAT and secondly around every very high energy source identified as a PWN or a PWN candidate are presented in this dissertation. These studies bring new insights and constraints on the physical properties of the sources as well as on emitting processes in pulsar magnetospheres and in PWNe. (author)

  17. Preferential Hyperacuity Perimeter (PreView PHP) for detecting choroidal neovascularization study.

    Science.gov (United States)

    Alster, Yair; Bressler, Neil M; Bressler, Susan B; Brimacombe, Judith A; Crompton, R Michael; Duh, Yi-Jing; Gabel, Veit-Peter; Heier, Jeffrey S; Ip, Michael S; Loewenstein, Anat; Packo, Kirk H; Stur, Michael; Toaff, Techiya

    2005-10-01

    To assess the ability of the Preferential Hyperacuity Perimeter (PreView PHP; Carl Zeiss Meditec, Dublin, CA) to detect recent-onset choroidal neovascularization (CNV) resulting from age-related macular degeneration (AMD) and to differentiate it from an intermediate stage of AMD. Prospective, comparative, concurrent, nonrandomized, multicenter study. Eligible participants' study eyes had a corrected visual acuity of 20/160 or better and either untreated CNV from AMD diagnosed within the last 60 days or an intermediate stage of AMD. After obtaining consent, visual acuity with habitual correction, masked PHP testing, stereoscopic color fundus photography, and fluorescein angiography were performed. Photographs and angiograms were evaluated by graders masked to diagnosis and PHP results. The reading center's diagnosis determined if the patient was categorized as having intermediate AMD or neovascular AMD. A successful study outcome was defined a priori as a sensitivity of at least 80% and a specificity of at least 80%. Of 185 patients who gave consent to be enrolled, 11 (6%) had PHP results judged to be unreliable. An additional 52 were not included because they did not meet all eligibility criteria. Of the remaining 122 patients, 57 had an intermediate stage of AMD and 65 had neovascular AMD. The sensitivity to detect newly diagnosed CNV using PHP testing was 82% (95% confidence interval [CI], 70%-90%). The specificity to differentiate newly diagnosed CNV from the intermediate stage of AMD using PHP testing was 88% (95% CI, 76%-95%). Preferential Hyperacuity Perimeter testing can detect recent-onset CNV resulting from AMD and can differentiate it from an intermediate stage of AMD with high sensitivity and specificity. These data suggest that monitoring with PHP should detect most cases of CNV of recent onset with few false-positive results at a stage when treatment usually would be beneficial. Thus, this monitoring should be considered in the management of the

  18. Results of Automated Retinal Image Analysis for Detection of Diabetic Retinopathy from the Nakuru Study, Kenya.

    Science.gov (United States)

    Hansen, Morten B; Abràmoff, Michael D; Folk, James C; Mathenge, Wanjiku; Bastawrous, Andrew; Peto, Tunde

    2015-01-01

    Digital retinal imaging is an established method of screening for diabetic retinopathy (DR). It has been established that currently about 1% of the world's blind or visually impaired is due to DR. However, the increasing prevalence of diabetes mellitus and DR is creating an increased workload on those with expertise in grading retinal images. Safe and reliable automated analysis of retinal images may support screening services worldwide. This study aimed to compare the Iowa Detection Program (IDP) ability to detect diabetic eye diseases (DED) to human grading carried out at Moorfields Reading Centre on the population of Nakuru Study from Kenya. Retinal images were taken from participants of the Nakuru Eye Disease Study in Kenya in 2007/08 (n = 4,381 participants [NW6 Topcon Digital Retinal Camera]). First, human grading was performed for the presence or absence of DR, and for those with DR this was sub-divided in to referable or non-referable DR. The automated IDP software was deployed to identify those with DR and also to categorize the severity of DR. The primary outcomes were sensitivity, specificity, and positive and negative predictive value of IDP versus the human grader as reference standard. Altogether 3,460 participants were included. 113 had DED, giving a prevalence of 3.3% (95% CI, 2.7-3.9%). Sensitivity of the IDP to detect DED as by the human grading was 91.0% (95% CI, 88.0-93.4%). The IDP ability to detect DED gave an AUC of 0.878 (95% CI 0.850-0.905). It showed a negative predictive value of 98%. The IDP missed no vision threatening retinopathy in any patients and none of the false negative cases met criteria for treatment. In this epidemiological sample, the IDP's grading was comparable to that of human graders'. It therefore might be feasible to consider inclusion into usual epidemiological grading.

  19. Estimating movement and survival rates of a small saltwater fish using autonomous antenna receiver arrays and passive integrated transponder tags

    Science.gov (United States)

    Rudershausen, Paul J.; Buckel, Jeffery A.; Dubreuil, Todd; O'Donnell, Matthew J.; Hightower, Joseph E.; Poland, Steven J.; Letcher, Benjamin H.

    2014-01-01

    We evaluated the performance of small (12.5 mm long) passive integrated transponder (PIT) tags and custom detection antennas for obtaining fine-scale movement and demographic data of mummichog Fundulus heteroclitus in a salt marsh creek. Apparent survival and detection probability were estimated using a Cormack Jolly Seber (CJS) model fitted to detection data collected by an array of 3 vertical antennas from November 2010 to March 2011 and by a single horizontal antenna from April to August 2011. Movement of mummichogs was monitored during the period when the array of vertical antennas was used. Antenna performance was examined in situ using tags placed in wooden dowels (drones) and in live mummichogs. Of the 44 tagged fish, 42 were resighted over the 9 mo monitoring period. The in situ detection probabilities of the drone and live mummichogs were high (~80-100%) when the ambient water depth was less than ~0.8 m. Upstream and downstream movement of mummichogs was related to hourly water depth and direction of tidal current in a way that maximized time periods over which mummichogs utilized the intertidal vegetated marsh. Apparent survival was lower during periods of colder water temperatures in December 2010 and early January 2011 (median estimate of daily apparent survival = 0.979) than during other periods of the study (median estimate of daily apparent survival = 0.992). During late fall and winter, temperature had a positive effect on the CJS detection probability of a tagged mummichog, likely due to greater fish activity over warmer periods. During the spring and summer, this pattern reversed possibly due to mummichogs having reduced activity during the hottest periods. This study demonstrates the utility of PIT tags and continuously operating autonomous detection systems for tracking fish at fine temporal scales, and improving estimates of demographic parameters in salt marsh creeks that are difficult or impractical to sample with active fishing gear.

  20. Parametric Study of Defect Detection in Pipes with Bend Using Guided Ultrasonic Waves

    Directory of Open Access Journals (Sweden)

    Jack Tan Jin

    2016-01-01

    Full Text Available The propagation behaviour of guided ultrasonic waves in a steel pipe with welded bend is studied by finite element simulation. The effectiveness of the longitudinal L(0,2 and torsional T(0,1 guided waves in detecting circumferential cut near the weld is investigated. In order to identify the presence of the defect, the reflection strength due to the cut is studied. The geometry of the weld is constructed based on common V-bevel butt joints and the anisotropy of the 316L stainless steel weld is included to correctly predict the scattering of ultrasonic waves. The finite element model is built to allow high accuracy. Detection of small circumferential cut (up to 60° circumferential extent can be achieved with longitudinal L(0,2 mode. Detection of moderate to large circumferential cut can be achieved by torsional T(0,1 or longitudinal L(0,2 modes, with T(0,1 mode preferred due to its less mode conversion to higher order modes.

  1. Study of optical confinement of quantum cascade lasers and applications to detection

    International Nuclear Information System (INIS)

    Moreau, Virginie

    2008-01-01

    Quantum cascade lasers have been invented in 1994 and they have already established themselves as the semiconductor laser source of choice in the mid- and far-infrared ranges of the electromagnetic spectrum. As most molecules of chemical interest exhibit roto-vibrational transitions in these spectral ranges, quantum cascade lasers are especially suited for applications such as spectroscopy, trace gas detection or medical imaging. One of the current leading research axis targets the device optimization and miniaturization, with possible applications in detection microsystems. This PhD thesis work focused on the study and optimization of the vertical optical confinement in quantum cascade lasers featuring optical waveguides without top cladding layers. These structures are interesting because they are compatible with two different guiding mechanisms at the same time, i.e. surface-plasmons and air confinement. The study of the characteristics of the optical mode and of the electrical current dispersion allowed us to conceive original structures which open new perspectives, for instance in the domain of analytic detection in a fluidic environment. Furthermore, we have shown that the observation by near field microscopy is a powerful tool to characterize and understand quantum cascade lasers. Finally, we have laid the foundations for the optimization of miniaturized arrays of single-mode lasers based on photonic crystal technology. (author) [fr

  2. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  3. A comparative study on methods of improving SCR for ship detection in SAR image

    Science.gov (United States)

    Lang, Haitao; Shi, Hongji; Tao, Yunhong; Ma, Li

    2017-10-01

    Knowledge about ship positions plays a critical role in a wide range of maritime applications. To improve the performance of ship detector in SAR image, an effective strategy is improving the signal-to-clutter ratio (SCR) before conducting detection. In this paper, we present a comparative study on methods of improving SCR, including power-law scaling (PLS), max-mean and max-median filter (MMF1 and MMF2), method of wavelet transform (TWT), traditional SPAN detector, reflection symmetric metric (RSM), scattering mechanism metric (SMM). The ability of SCR improvement to SAR image and ship detection performance associated with cell- averaging CFAR (CA-CFAR) of different methods are evaluated on two real SAR data.

  4. Study of surface functionalization on IDE by using 3-aminopropyl triethoxysilane (APTES) for cervical cancer detection

    Science.gov (United States)

    Raqeema, S.; Hashim, U.; Azizah, N.

    2016-07-01

    This paper presented the study of surface functionalization on IDE by using 3-Aminopropyl triethoxysilane (APTES). The DNA nanochip based interdigitated (IDE) has been proposed to optimized the sensitivity of the device due to the cervical cancer detection. The DNA nanochip will be more efficient using surface modification of TiO2 nanoparticles with 3-Aminopropyl triethoxysilane (APTES). Furthermore, APTES gain the better functionalization of the adsorption mechanism on IDE. The combination of the DNA probe and the HPV target will produce more sensitivity and speed of the DNA nanochip due to their properties. The IDE has been characterized using current-voltage (IV) measurement. This functionalization of the surface would be applicable, sensitive, selective and low cost for cervical cancer detection.

  5. Experimental study on the detection of free fluids and gases in waste packages by acoustic methods

    International Nuclear Information System (INIS)

    Eisenblaetter, J.; Schaefer, P.; Weib, R.

    1992-01-01

    The objective of the project was to evaluate the potential and the limits of various nondestructive methods for testing the contents of 200-litre drums filled with radioactive waste. The following test problems were to be studied: 1. Detection of free water on the surface of the waste matrix (concrete); 2. Determination of the waste matrix level; 3. Determination of internal gas pressure. The following methods were found to be suitable: For Test problem 1: Measurement of Lamb wave attenuation, Acoustic impedance measurement (AIM) and Analysis of swash sound; For Test problem 2: Acoustic impedance measurement (AIM) and Measurement of Lamb wave attenuation; For Test problem 3: A method of pressure compensation and Analysis of cover resonances after striking the cover. It was not possible, however, to detect the concrete level by localisation of friction points using acoustic emission methods. 53 figs

  6. Experimental Study on Corrosion Detection of Aluminum Alloy Using Lamb Wave Mixing Technique

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heeung; Lee, Jaesun; Cho, Younho [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2016-11-15

    In this study, the Lamb wave mixing technique, which is basised on advanced research on the nonlinear bulk wave mixing technique, is applied for corrosion detection. To demonstrate the validity of the Lamb wave mixing technique, an experiment was performed with normal and corroded specimens. Comparison group in an experimentation are selected to mode and frequency with dominant in-plane displacement and out-of-plane displacement of Lamb waves. The results showed that the Lamb wave mixing technique can monitor corrosion defects, and it has a trend similar to that of the conventional Lamb wave technique. It was confirmed that the dominant displacement and mode matching the theory were generated. Flaw detectability is determined depending on displacement ratio instead of using the measurement method and mode selection.

  7. Plan of studies on fuel failure detection in Rikkyo Research Reactor

    International Nuclear Information System (INIS)

    Matsuura, T.; Nagahara, T.; Hattori, M.; Kawaguchi, K.

    1987-01-01

    Studies on fuel failure detection in Rikkyo Research Reactor have recently been begun in the following four approaches. (1) Accumulation of the data on the concentration of the short-lived radioactivity originating from FP rare gases contained in the air on the water surface of the reactor tank. (2) Accumulation of the data on the concentration of FP (especially 131 I) in the water of the reactor tank. (3) Design and preparation of a ''sniffer'' by which the location of the failed fuel element can be detected, when some anomaly is found in the above two routine measurements. (4) Design and preparation of a vessel containing a fuel element, which can be useful both for ''sipping'' inspection of the fuel element and for storage of the damaged fuel element. In this paper, an outline of the above approaches and the results of some preliminary experiments are reported. (author)

  8. Association Between Screen-Detected Gallstone Disease and Cancer in a Cohort Study

    DEFF Research Database (Denmark)

    Shabanzadeh, Daniel Mønsted; Sørensen, Lars Tue; Jørgensen, Torben

    2017-01-01

    , sigmoid colon, and rectal cancers were not associated with gallstone disease. Breast cancer had a weak association with gallstone disease depending on other factors (10.6% of patients with gallstone disease vs 7.41% without; hazard ratio, 1.44; 95% confidence interval, 0.99-2.11). Pooled...... ratio, 1.50; 95% confidence interval, 1.12-2.01). Right-side colon cancer was also associated with gallstone disease (2.57% of patients with gallstone disease vs 0.96% without; hazard ratio, 2.04; 95% confidence interval, 1.10-3.78). Pancreatic, esophageal, gastric, pooled colorectal, left-side colon...... nongastrointestinal and prostate cancers were not associated with gallstone disease. Conclusions: Screen-detected gallstone disease in the general population is associated with pooled gastrointestinal and right-side colon cancers. These associations are not due to detection bias or cholecystectomy. Further studies...

  9. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation methods (least error squares and filtering)

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the ''primary coolant circuit inventory monitoring'' of a pressurized water reactor. A reference model is developed in view of an automatic system ensuring detection and diagnostic in real time. The methods used for the present application are statistical tests and a method related to pattern recognition. The estimation of failures detected, difficult owing to the non-linearity of the problem, is treated by the least error squares method of the predictor or corrector type, and by filtering. It is in this frame that a new optimized method with superlinear convergence is developed, and that a segmented linearization of the model is introduced, in view of a multiple filtering [fr

  10. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  11. Detection of patient psychological distress and longitudinal patient-doctor relationships: a cross-sectional study.

    Science.gov (United States)

    Ridd, Matthew; Lewis, Glyn; Peters, Tim J; Salisbury, Chris

    2012-03-01

    Psychological distress in patients who attend their GP is thought to be under-recognised. However, it is likely that both disclosure and detection are influenced by how well the patient and doctor know each another. To examine whether patient-doctor depth of relationship is associated with identification of psychological distress. Cross-sectional study in general practices in and around Bristol, England. Patients (aged ≥16 years) were asked to complete a questionnaire and consent to their electronic medical records being reviewed. Study GPs independently assessed patient psychological distress. Multivariable logistic regression was used to look for associations between patient-doctor depth of relationship and GP detection of patient psychological distress (defined according to the 12-item General Health Questionnaire, GHQ-12). There were 643 eligible appointments with 31 GPs. In total, 541 (84.1%) patients returned questionnaires and 490 (76.2%) consented to their records being reviewed. Patient-doctor depth of relationship was not associated with GP detection of mild to severe patient psychological distress (adjusted odds ratio [OR] 0.94, 95% CI = 0.87 to 1.02) but, in secondary analyses, it was associated with the identification of moderate to severe distress (adjusted OR 1.13, 95% CI = 1.02 to 1.26). GPs reported more patient psychological distress in patients who reported a greater depth of relationship but this did not relate to patients' GHQ-12 scores. Evidence to support an association between patient-doctor depth of relationship and improved GP detection of patients with psychological distress was weak, except in those patients who GPs thought were more distressed. GPs may overestimate emotional distress in patients who report deeper patient-doctor relationships.

  12. Detection of patient psychological distress and longitudinal patient–doctor relationships: a cross-sectional study

    Science.gov (United States)

    Ridd, Matthew; Lewis, Glyn; Peters, Tim J; Salisbury, Chris

    2012-01-01

    Background Psychological distress in patients who attend their GP is thought to be under-recognised. However, it is likely that both disclosure and detection are influenced by how well the patient and doctor know each another. Aim To examine whether patient–doctor depth of relationship is associated with identification of psychological distress. Design and setting Cross-sectional study in general practices in and around Bristol, England. Method Patients (aged ≥16 years) were asked to complete a questionnaire and consent to their electronic medical records being reviewed. Study GPs independently assessed patient psychological distress. Multivariable logistic regression was used to look for associations between patient–doctor depth of relationship and GP detection of patient psychological distress (defined according to the 12-item General Health Questionnaire, GHQ-12). Results There were 643 eligible appointments with 31 GPs. In total, 541 (84.1%) patients returned questionnaires and 490 (76.2%) consented to their records being reviewed. Patient–doctor depth of relationship was not associated with GP detection of mild to severe patient psychological distress (adjusted odds ratio [OR] 0.94, 95% CI = 0.87 to 1.02) but, in secondary analyses, it was associated with the identification of moderate to severe distress (adjusted OR 1.13, 95% CI = 1.02 to 1.26). GPs reported more patient psychological distress in patients who reported a greater depth of relationship but this did not relate to patients' GHQ-12 scores. Conclusion Evidence to support an association between patient–doctor depth of relationship and improved GP detection of patients with psychological distress was weak, except in those patients who GPs thought were more distressed. GPs may overestimate emotional distress in patients who report deeper patient–doctor relationships. PMID:22429433

  13. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Science.gov (United States)

    Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung

    2017-01-01

    To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  14. Neuropathic pain and use of PainDETECT in patients with fibromyalgia: a cohort study.

    Science.gov (United States)

    Gauffin, Jarno; Hankama, Tiina; Kautiainen, Hannu; Hannonen, Pekka; Haanpää, Maija

    2013-02-14

    Fibromyalgia has a plethorae of symptoms, which can be confusing and even misleading. Accurate evaluation is necessary when patients with fibromyalgia are treated. Different types of instruments are available for the clinicians to supplement evaluation. Our objective was to study the applicability of the PainDETECT instrument to screen neuropathic pain in patients with fibromyalgia. 158 patients with primary fibromyalgia underwent a neurological examination including bedside sensory testing. They also fulfilled four questionnaires: PainDETECT, Beck depression inventory IA (BDI IA), Fibromyalgia Impact Questionnaire (FIQ) and a self-made questionnaire regarding present pain and pain relieving methods of the patients. The results of the clinical evaluation and questionnaires were then compared. Clinically verified neuropathic pain was diagnosed in 53/158 [34% (95% Cl: 26 to 41)] patients. The ROC curve achieved a maximum Youden´s index at score of 17 when sensitivity was 0.79 (95% Cl: 0.66 to 0.89) and specificity 0.53 (95% Cl: 0.43 to 0.63). The PainDETECT total score (OR: 1.14 95% Cl: 1.06 to 1.22), FM as the worst current pain (OR: 0.31; 95% 0.16 to 0.62), body mass index (BMI) (OR: 1.05; 95% Cl: 1.00 to 1.11) and the intensity of current pain (OR: 1.20; 95% Cl: 1.01 to 1.41) were significantly associated with the presence of neuropathic pain in univariate analyses. This study highlights the importance of thorough clinical examination. The Neuropathic pain screening tool PainDETECT is not as useful in patients with fibromyalgia as in patients with uncompromised central pain control.

  15. Neuropathic pain and use of PainDETECT in patients with fibromyalgia: a cohort study

    Directory of Open Access Journals (Sweden)

    Gauffin Jarno

    2013-02-01

    Full Text Available Abstract Backround Fibromyalgia has a plethorae of symptoms, which can be confusing and even misleading. Accurate evaluation is necessary when patients with fibromyalgia are treated. Different types of instruments are available for the clinicians to supplement evaluation. Our objective was to study the applicability of the PainDETECT instrument to screen neuropathic pain in patients with fibromyalgia. Methods 158 patients with primary fibromyalgia underwent a neurological examination including bedside sensory testing. They also fulfilled four questionnaires: PainDETECT, Beck depression inventory IA (BDI IA, Fibromyalgia Impact Questionnaire (FIQ and a self-made questionnaire regarding present pain and pain relieving methods of the patients. The results of the clinical evaluation and questionnaires were then compared. Results Clinically verified neuropathic pain was diagnosed in 53/158 [34% (95% Cl: 26 to 41] patients. The ROC curve achieved a maximum Youden´s index at score of 17 when sensitivity was 0.79 (95% Cl: 0.66 to 0.89 and specificity 0.53 (95% Cl: 0.43 to 0.63. The PainDETECT total score (OR: 1.14 95% Cl: 1.06 to 1.22, FM as the worst current pain (OR: 0.31; 95% 0.16 to 0.62, body mass index (BMI (OR: 1.05; 95% Cl: 1.00 to 1.11 and the intensity of current pain (OR: 1.20; 95% Cl: 1.01 to 1.41 were significantly associated with the presence of neuropathic pain in univariate analyses. Conclusion This study highlights the importance of thorough clinical examination. The Neuropathic pain screening tool PainDETECT is not as useful in patients with fibromyalgia as in patients with uncompromised central pain control.

  16. Feasibility study on RI biochip Application to detection of risk factors of atherosclerosis

    International Nuclear Information System (INIS)

    Ko, Kyong Cheol; Choi, Mi Hee; Park, Sang Hyun; Cho, Kyung Hyun; Lee, Ki Teak

    2009-01-01

    Microarrays can be used to screen thousands of binding events in a parallel and high throughput fashion and are of major importance in discase diagnosis and drug discovery. The use of radioisotope is conventionally regarded as one of the most sensitive detection methods. Atherosclerosis is a common disorder affecting arterial blood vessels. It happens when fat, cholesterol, and other substances made in the arterial blood vessels form a hard substances called plaque. Lipoprotein-associated phospholipase A 2 (Lp-PLA 2 ), a phospholipase A 2 enzyme, is used as a marker for cardiac disease. The detection of Lp-PLA 2 was accomplished by using radioactive [ 3 H-acetyl] PAF as a substrate and a feasibility study on RI biochip application to detection of Lp-PLA 2 , a risk factors of atherosclerosis was performed. Inhibitive activity of a native plant extract was also determined by using the RI biochip. It was found to be applicable to a high-throughput screening of inhibitors for developing atherosclerosis therapeutic agents

  17. The study on the lidar's detection limit for Iodine Gas

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-lyul; Baik, Seung-Hoon; Park, Seung-Kyu; Park, Nak-Gyu; Ahn, Yong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A powerful and reliable tool for range-resolved remote sensing of gas concentrations that has proven its capabilities in a variety of studies is the differential absorption lidar (DIAL). Differential absorption lidar (DIAL) is frequently used for atmospheric gas monitoring to detect impurities such as nitrogen dioxide, sulfur dioxide, iodine, and ozone. DIAL can measure air pollutant concentrations with a high spatial resolution by adopting two laser systems with different degrees of absorption between the two different wavelengths. The absorption of the reference wavelength is very weak, while the absorption of the other wavelength is very strong. In this paper, we measured the limit of detection capability of our designed DIAL system. The DIAL measurements were performed using a target iodine cell in the laboratory. We confirmed that the concentration of iodine gas ratio increased after the laser passed through the iodine cell. The system of DIAL(Differential Absorption Lidar) was effective to detect the iodine gas. We obtained the signals from the iodine target cell and the lidar signal from the iodine target cell was proportional to frequency locking ratios.

  18. Study on Analysis and Pattern Recognition of the Manifestation of the Pulse Detection of Cerebrovascular Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jing, J; Wang, Y C; Hong, W X; Zhang, W P [Department of Biomedical Engineering, University of Yanshan, Qinhuangdao, Hebei Province, 066004 (China)

    2006-10-15

    Cerebrovascular Disease (CVD) is also called stroke in Traditional Chinese Medicine (TCM). CVD is a kind of frequent diseases with high incidence, high death rate, high deformity rate and high relapse rate. The pathogenesis of CVD has relation to many factors. In modern medicine, we can make use of various instruments to check many biochemical parameters. However, at present, the early detection of CVD can mostly be done artificially by specialists. In TCM the salted expert can detect the state of a CVD patient by felling his (or her) pulse. It is significant to apply the modern information and engineering techniques to the early discovery of CVD. It is also a challenge to do this in fact. In this paper, the authors presented a detection method of CVD basing on analysis and pattern recognition of Manifestation of the Pulse of TCM using wavelet technology and Neural Networks. Pulse signals from normal health persons and CVD patients were studied comparatively. This research method is flexible to deal with other physiological signals.

  19. Prognosis of screen-detected breast cancers: results of a population based study

    Directory of Open Access Journals (Sweden)

    Rashid Ivan

    2006-01-01

    Full Text Available Abstract Background The reduced mortality rate from breast carcinoma among women offered screening mammography is demonstrated after 15–20 years of follow-up. However, the assessment of 5-year overall and event-free survival could represent an earlier measure of the efficacy of mammography screening program (MSP. Methods All cases of breast cancer diagnosed in the Province of Modena between years 1996 and 2000 in women aged 50 to 69 years, were identified through the Modena Cancer Registry (MCR. Stage of disease and treatment information were obtained from clinical records. All the events occurring up to June 30, 2003 were retrieved by experienced monitors. Five-year overall and event-free survival were the principal end-points of the study. Results During a 5-year period, 587 primary breast cancers were detected by the MSP and 471 primary breast cancers were diagnosed out of the MSP. The screen-detected breast cancers were smaller, more likely node negative, with low histological grade, low proliferative activity and positive receptors status. Furthermore, the breast cancer diagnosed through the MSP more frequently received a conservative surgery. The 5-year survival rate was 94% in the screen-detected group, versus 84% in the other group (p = 0.0001. The rate of 5-year event-free survival was 89% and 75% for the MSP participants and not participants, respectively (p = 0.0001. Conclusions Our data confirm a favourable outcome of screen-detected breast cancers in terms of five-year overall and event-free survival, which reflect the good quality assurance parameters of the MSP. Finally, a cancer registry should be implemented in every area covered by screening programs.

  20. Literature study regarding fire protection in nuclear power plants. Part 2: Fire detection and -extinguishing systems

    International Nuclear Information System (INIS)

    Isaksson, S.

    1996-01-01

    This literature study has been made on behalf of the Swedish Nuclear Power Inspectorate. The aim is to describe different aspects of fire protection in nuclear power plants. Detection and extinguishing systems in Swedish nuclear power plants have only to a limited extent been designed after functional demands, such as a maximum acceptable damage or a maximum time to detect a fire. The availability of detection systems is difficult to assess, partly because of lack of statistics. The user interface is very important in complex systems as nuclear plants. An extinguishing system designed according to the insurance companies' regulations will only fulfill the basic demands. It should be noted that normal sprinkler design does not aim for extinguishing fires, the objective is to control fire until manual extinguishment is possible. There is a great amount of statistics on wet and dry pipe sprinkler systems, while statistics are more scarce for deluge systems. The statistics on the reliability of gaseous extinguishing systems have been found very scarce. A drawback of these systems is that they are normally designed for one shot only. There are both traditional and more recent extinguishing systems that can replace halons. From now on there will be a greater need for a thorough examination of the properties needed for the individual application and a quantification of the acceptable damage. There are several indications on the importance of a high quality maintenance program as well as carefully developed routines for testing and surveillance to ensure the reliability of detection and extinguishing systems. 78 refs, 8 figs, 10 tabs

  1. Collaborative study of a qualitative TLC-method for detection of antioxidants (BHA, BHT, gallates and NDGA) in food

    DEFF Research Database (Denmark)

    Guldborg, Merethe

    1981-01-01

    -proposed method, and an official French method. After extraction, the compounds are detected by TLC. Being a qualitative method the probability of obtaining correct results is a measure of the goodness of the method, and the study examines the influence on the probability of the following 3 factors: type...... of antioxidant, type of food, and concentration of antioxidant. From the study is was concluded that the method worked quite well for BHA, with a detection limit about 15 mg/kg, whereas it worked badly for BHT, the detection limit being higher than 30 mg/kg. For the gallates and NDGA the detection limit was 30...

  2. Studies of ground-state dynamics in isolated species by ionization-detected stimulated Raman techniques

    Energy Technology Data Exchange (ETDEWEB)

    Felker, P.M. [Univ. of California, Los Angeles (United States)

    1993-12-01

    First, the author aims to develop methods of nonlinear Raman spectroscopy for application in studies of sparse samples. Second, the author wishes to apply such methods to structural and dynamical studies of species (molecules, complexes, and clusters) in supersonic molecular beams. In the past year, the author has made progress in several areas. The first pertains to the application of mass-selective ionization-detected stimulated Raman spectroscopies (IDSRS) to the size-specific vibrational spectroscopy of solute-solvent{sub n} clusters. The second involves the application of IDSRS methods to studies of jet-cooled benzene clusters. The third pertains to the use of IDSRS methods in the study of intermolecular vibrational transitions in van der Waals complexes.

  3. Semi-automatic detection and correction of body organ motion, particularly cardiac motion in SPECT studies

    International Nuclear Information System (INIS)

    Quintana, J.C.; Caceres, F.; Vargas, P.

    2002-01-01

    Aim: Detect patient motion during SPECT imaging. Material and Method: SPECT study is carried out on a patient's body organ, such as the heart, and frame of image data are thereby acquired. The image data in these frames are subjected to a series of mappings and computations, from which frame containing a significant quantity of organ motion can be identified. Quantification of motion occurs by shifting some of the mapped data within a predetermined range, and selecting that data shift which minimizes the magnitude of a motion sensitive mathematical function. The sensitive mathematical function is constructed from all set of image frames using the pixel data within a region covering the body organ. Using cine display of planar image data, the operator defines the working region by marking two points, which define two horizontal lines covering the area of the body organ. This is the only operator intervention. The mathematical function integrates pixel data from all set of image frames and therefore does not use derivatives which may cause distortion in noisy data. Moreover, as a global function, this method is superior than that using frame-to-frame cross-correlation function to identify motion between adjacent frames. Using standard image processing software, the method was implemented computationally. Ten SPECT studies with movement (Sestamibi cardiac studies and 99m-ECD brain SPECT studies) were selected plus two others with no movement. The acquisition SPECT protocol for the cardiac study was as follow: Step and shoot mode, non-circular orbit, 64 stops 20s each, 64x64x16 matrix and LEHR colimator. For the brain SPECT, 128 stops over 360 0 were used. Artificial vertical displacements (±1-2 pixels) over several frames were introduced in those studies with no movement to simulate patient motion. Results: The method was successfully tested in all cases and was capable to recognize SPECT studies with no body motion as well as those with body motion (both from the

  4. Stream computing for biomedical signal processing: A QRS complex detection case-study.

    Science.gov (United States)

    Murphy, B M; O'Driscoll, C; Boylan, G B; Lightbody, G; Marnane, W P

    2015-01-01

    Recent developments in "Big Data" have brought significant gains in the ability to process large amounts of data on commodity server hardware. Stream computing is a relatively new paradigm in this area, addressing the need to process data in real time with very low latency. While this approach has been developed for dealing with large scale data from the world of business, security and finance, there is a natural overlap with clinical needs for physiological signal processing. In this work we present a case study of streams processing applied to a typical physiological signal processing problem: QRS detection from ECG data.

  5. Study on the solid state track detector with controllable detection sensitivity

    International Nuclear Information System (INIS)

    Tsuruta, Takao; Koguchi, Yasuhiro; Ashida, Taro

    2003-01-01

    In a study aimed at the determination of threshold vale for detection of heavy ions, several types of copolymers of DAP and CR-39 have been irradiated with several kinds of ions at the middle-energy port and bio-port of National Institute of Radiological Sciences-Heavy Ion Medical Accelerator in Chiba (NIRS-HIMAC). As a results, the thresholds are 55, 99, 124 and 224 keV/μm in water for 50%, 60%, 70% and 80% of DAP concentration, respectively. (author)

  6. Comparative Study of Parametric and Non-parametric Approaches in Fault Detection and Isolation

    DEFF Research Database (Denmark)

    Katebi, S.D.; Blanke, M.; Katebi, M.R.

    This report describes a comparative study between two approaches to fault detection and isolation in dynamic systems. The first approach uses a parametric model of the system. The main components of such techniques are residual and signature generation for processing and analyzing. The second...... approach is non-parametric in the sense that the signature analysis is only dependent on the frequency or time domain information extracted directly from the input-output signals. Based on these approaches, two different fault monitoring schemes are developed where the feature extraction and fault decision...

  7. Dual-mode endomicroscopy for detection of epithelial dysplasia in the mouth: a descriptive pilot study

    Science.gov (United States)

    Bodenschatz, Nico; Poh, Catherine F.; Lam, Sylvia; Lane, Pierre; Guillaud, Martial; MacAulay, Calum E.

    2017-08-01

    Dual-mode endomicroscopy is a diagnostic tool for early cancer detection. It combines the high-resolution nuclear tissue contrast of fluorescence endomicroscopy with quantified depth-dependent epithelial backscattering as obtained by diffuse optical microscopy. In an in vivo pilot imaging study of 27 oral lesions from 21 patients, we demonstrate the complementary diagnostic value of both modalities and show correlations between grade of epithelial dysplasia and relative depth-dependent shifts in light backscattering. When combined, the two modalities provide diagnostic sensitivity to both moderate and severe epithelial dysplasia in vivo.

  8. Study of hydrogenated amorphous silicon devices under intense electric field: application to nuclear detection

    International Nuclear Information System (INIS)

    Ilie, A.

    1996-01-01

    The goal of this work was the study, development and optimization of hydrogenated amorphous silicon (a-Si:H) devices for use in detection of ionizing radiation in applications connected to the nuclear industry. Thick p-i-n devices, capable of withstanding large electric fields (up to 10 6 V/cm) with small currents (nA/cm 2 ), were proposed and developed. In order to decrease fabrication time, films were made using the 'He diluted' PECVD process and compared to standard a-Si:H films. Aspects connected to specific detector applications as well as to the fundamental physics of a-Si:H were considered: the internal electric field technique, in which the depletion charge was measured as a function of the applied bias voltage; study of the leakage current of p-i-n devices permitted us to demonstrate different regimes: depletion, field-enhanced thermal generation and electronic injection across the p layer. The effect of the electric field on the thermal generation of the carriers was studied considering the Poole-Frenkel and tunneling mechanisms. A model was developed taking under consideration the statistics of the correlated states and electron-phonon coupling. The results suggest that mechanisms not included in the 'standard model' of a Si:h need to be considered, such as defect relaxation, a filed-dependent mobility edge etc...; a new metastable phenomenon, called 'forming', induced by prolonged exposure to a strong electric field, was observed and studied. It is characterized by marked decrease of the leakage current and the detector noise, and increase in the breakdown voltage, as well as an improvement of carrier collection efficiency. This forming process appears to be principally due to an activation of the dopants in the p layer; finally, the capacity of thick p-i-n a Si:H devices to detect ionizing radiation has been evaluated. We show that it is possible, with 20-50 micron thick p-i-n devices, to detect the full spectrum of alpha and beta particles. With an

  9. Numerical Study of Plasmonic Efficiency of Gold Nanostripes for Molecule Detection

    Directory of Open Access Journals (Sweden)

    Thomas Grosges

    2015-01-01

    Full Text Available In plasmonics, the accurate computation of the electromagnetic field enhancement is necessary in determining the amplitude and the spatial extension of the field around nanostructures. Here, the problem of the interaction between an electromagnetic excitation and gold nanostripes is solved. An optimization scheme, including an adaptive remeshing process with error estimator, is used to solve the problem through a finite element method. The variations of the electromagnetic field amplitude and the plasmonic active zones around nanostructures for molecule detection are studied in this paper taking into account the physical and geometrical parameters of the nanostripes. The evolution between the sizes and number of nanostripes is shown.

  10. Numerical Study of Plasmonic Efficiency of Gold Nanostripes for Molecule Detection

    Science.gov (United States)

    2015-01-01

    In plasmonics, the accurate computation of the electromagnetic field enhancement is necessary in determining the amplitude and the spatial extension of the field around nanostructures. Here, the problem of the interaction between an electromagnetic excitation and gold nanostripes is solved. An optimization scheme, including an adaptive remeshing process with error estimator, is used to solve the problem through a finite element method. The variations of the electromagnetic field amplitude and the plasmonic active zones around nanostructures for molecule detection are studied in this paper taking into account the physical and geometrical parameters of the nanostripes. The evolution between the sizes and number of nanostripes is shown. PMID:25734184

  11. Generation, detection and spectroscopic studies of high-frequency nonequilibrium phonons in crystals

    International Nuclear Information System (INIS)

    Dennis, W.M.; Yen, W.M.

    2007-01-01

    In this article we will review studies conducted in the past two decades on the dynamic properties of high-frequency (THz) phonons generated monochromatically with high power far infrared (FIR) laser pulses using defect-induced phonon absorption and detected using a vibronic sideband spectrometer fashioned after that devised by Kaplyanskii, the honoree of this special issue. The temporal and spectral evolution of the phonon signature provides information on the mechanisms that dominate the relaxation of high-frequency phonons in real crystals

  12. Study on loss detection algorithms for tank monitoring data using multivariate statistical analysis

    International Nuclear Information System (INIS)

    Suzuki, Mitsutoshi; Burr, Tom

    2009-01-01

    Evaluation of solution monitoring data to support material balance evaluation was proposed about a decade ago because of concerns regarding the large throughput planned at Rokkasho Reprocessing Plant (RRP). A numerical study using the simulation code (FACSIM) was done and significant increases in the detection probabilities (DP) for certain types of losses were shown. To be accepted internationally, it is very important to verify such claims using real solution monitoring data. However, a demonstrative study with real tank data has not been carried out due to the confidentiality of the tank data. This paper describes an experimental study that has been started using actual data from the Solution Measurement and Monitoring System (SMMS) in the Tokai Reprocessing Plant (TRP) and the Savannah River Site (SRS). Multivariate statistical methods, such as a vector cumulative sum and a multi-scale statistical analysis, have been applied to the real tank data that have superimposed simulated loss. Although quantitative conclusions have not been derived for the moment due to the difficulty of baseline evaluation, the multivariate statistical methods remain promising for abrupt and some types of protracted loss detection. (author)

  13. Enhanced detection and study of murine norovirus-1 using a more efficient microglial cell line

    Directory of Open Access Journals (Sweden)

    Lu Yuanan

    2009-11-01

    Full Text Available Abstract Background Human Noroviruses are the predominant cause of non-bacterial gastroenteritis worldwide. To facilitate prevention and control, a norovirus isolated from mice can provide a model to understand human noroviruses. To establish optimal viral infectivity conditions for murine noroviruses, several cell lines of hematopoietic lineage, including murine BV-2, RAW 264.7, and TIB, as well as human CHME-5, were tested comparatively for their sensitivity to murine norovirus-1. Results Except for CHME-5, all three murine-derived cell lines were susceptible to MNV infection. Viral infection of these cells was confirmed by RT-PCR. Using both viral plaque and replication assays, BV-2 and RAW 264.7 cells were determined to have comparable sensitivities to MNV-1 infection. Comparisons of cell growth characteristics, general laboratory handling and potential in-field applications suggest the use of BV-2 to be more advantageous. Conclusion Results obtained from these studies demonstrate that an immortalized microglial cell line can support MNV-1 replication and provides a more efficient method to detect and study murine noroviruses, facilitating future investigations using MNV-1 as a model to study, detect, and control Human Norovirus.

  14. On the direct detection of multi-component dark matter: sensitivity studies and parameter estimation

    Science.gov (United States)

    Herrero-Garcia, Juan; Scaffidi, Andre; White, Martin; Williams, Anthony G.

    2017-11-01

    We study the case of multi-component dark matter, in particular how direct detection signals are modified in the presence of several stable weakly-interacting-massive particles. Assuming a positive signal in a future direct detection experiment, stemming from two dark matter components, we study the region in parameter space where it is possible to distinguish a one from a two-component dark matter spectrum. First, we leave as free parameters the two dark matter masses and show that the two hypotheses can be significantly discriminated for a range of dark matter masses with their splitting being the critical factor. We then investigate how including the effects of different interaction strengths, local densities or velocity dispersions for the two components modifies these conclusions. We also consider the case of isospin-violating couplings. In all scenarios, we show results for various types of nuclei both for elastic spin-independent and spin-dependent interactions. Finally, assuming that the two-component hypothesis is confirmed, we quantify the accuracy with which the parameters can be extracted and discuss the different degeneracies that occur. This includes studying the case in which only a single experiment observes a signal, and also the scenario of having two signals from two different experiments, in which case the ratios of the couplings to neutrons and protons may also be extracted.

  15. Effectiveness of reactive case detection for malaria elimination in three archetypical transmission settings: a modelling study.

    Science.gov (United States)

    Gerardin, Jaline; Bever, Caitlin A; Bridenbecker, Daniel; Hamainza, Busiku; Silumbe, Kafula; Miller, John M; Eisele, Thomas P; Eckhoff, Philip A; Wenger, Edward A

    2017-06-12

    Reactive case detection could be a powerful tool in malaria elimination, as it selectively targets transmission pockets. However, field operations have yet to demonstrate under which conditions, if any, reactive case detection is best poised to push a region to elimination. This study uses mathematical modelling to assess how baseline transmission intensity and local interconnectedness affect the impact of reactive activities in the context of other possible intervention packages. Communities in Southern Province, Zambia, where elimination operations are currently underway, were used as representatives of three archetypes of malaria transmission: low-transmission, high household density; high-transmission, low household density; and high-transmission, high household density. Transmission at the spatially-connected household level was simulated with a dynamical model of malaria transmission, and local variation in vectorial capacity and intervention coverage were parameterized according to data collected from the area. Various potential intervention packages were imposed on each of the archetypical settings and the resulting likelihoods of elimination by the end of 2020 were compared. Simulations predict that success of elimination campaigns in both low- and high-transmission areas is strongly dependent on stemming the flow of imported infections, underscoring the need for regional-scale strategies capable of reducing transmission concurrently across many connected areas. In historically low-transmission areas, treatment of clinical malaria should form the cornerstone of elimination operations, as most malaria infections in these areas are symptomatic and onward transmission would be mitigated through health system strengthening; reactive case detection has minimal impact in these settings. In historically high-transmission areas, vector control and case management are crucial for limiting outbreak size, and the asymptomatic reservoir must be addressed through

  16. An information-gain approach to detecting three-way epistatic interactions in genetic association studies

    DEFF Research Database (Denmark)

    Hu, Ting; Chen, Yuanzhu; Kiralis, Jeff W

    2013-01-01

    Background Epistasis has been historically used to describe the phenomenon that the effect of a given gene on a phenotype can be dependent on one or more other genes, and is an essential element for understanding the association between genetic and phenotypic variations. Quantifying epistasis......-way epistasis. Methods Such a measure is based on information gain, and is able to separate all lower order effects from pure three-way epistasis. Results Our method was verified on synthetic data and applied to real data from a candidate-gene study of tuberculosis in a West African population....... In the tuberculosis data, we found a statistically significant pure three-way epistatic interaction effect that was stronger than any lower-order associations. Conclusion Our study provides a methodological basis for detecting and characterizing high-order gene-gene interactions in genetic association studies....

  17. A comparative study of cultural methods for the detection of Salmonella in feed and feed ingredients

    Directory of Open Access Journals (Sweden)

    Haggblom Per

    2009-02-01

    Full Text Available Abstract Background Animal feed as a source of infection to food producing animals is much debated. In order to increase our present knowledge about possible feed transmission it is important to know that the present isolation methods for Salmonella are reliable also for feed materials. In a comparative study the ability of the standard method used for isolation of Salmonella in feed in the Nordic countries, the NMKL71 method (Nordic Committee on Food Analysis was compared to the Modified Semisolid Rappaport Vassiliadis method (MSRV and the international standard method (EN ISO 6579:2002. Five different feed materials were investigated, namely wheat grain, soybean meal, rape seed meal, palm kernel meal, pellets of pig feed and also scrapings from a feed mill elevator. Four different levels of the Salmonella serotypes S. Typhimurium, S. Cubana and S. Yoruba were added to each feed material, respectively. For all methods pre-enrichment in Buffered Peptone Water (BPW were carried out followed by enrichments in the different selective media and finally plating on selective agar media. Results The results obtained with all three methods showed no differences in detection levels, with an accuracy and sensitivity of 65% and 56%, respectively. However, Müller-Kauffmann tetrathionate-novobiocin broth (MKTTn, performed less well due to many false-negative results on Brilliant Green agar (BGA plates. Compared to other feed materials palm kernel meal showed a higher detection level with all serotypes and methods tested. Conclusion The results of this study showed that the accuracy, sensitivity and specificity of the investigated cultural methods were equivalent. However, the detection levels for different feed and feed ingredients varied considerably.

  18. Studies on L-histidine capped Ag and Au nanoparticles for dopamine detection

    Energy Technology Data Exchange (ETDEWEB)

    Nivedhini Iswarya, Chandrasekaran; Kiruba Daniel, S.C.G. [Division of Nanoscience and Technology, Anna University-BIT Campus, Tiruchirappalli 620024 (India); Sivakumar, Muthusamy, E-mail: muthusiva@gmail.com [Division of Nanoscience and Technology, Anna University-BIT Campus, Tiruchirappalli 620024 (India); Department of Chemistry, Anna University-BIT Campus, Tiruchirappalli 620024 (India)

    2017-06-01

    This work demonstrates the effective surface functionalization of Ag, Au and bimetallic Ag-Au nanoparticles using L-histidine for colorimetric detection of dopamine (DA) which plays majorly in recognizing the neurological disorder. L-Histidine (L-His) capped Ag, Au, and bimetallic Ag-Au nanoparticles are characterized using physico-chemical techniques. The optical behaviour of nanoparticles has been analysed at various time intervals using UV–Vis absorption spectroscopy. FT-IR results provide the evidence of chemical bonding between L-histidine and metal nanoparticles. Its structure with the capping of L-His was clearly shown in HR-TEM images. The average size of nanoparticles has calculated from TEM image fringes are 11 nm, 5 nm and 6.5 nm respectively, matches with crystals size calculated from X-ray diffraction pattern. Enhanced optical nature of nanoparticles provides the best platform to develop a colorimetric-based biosensor for DA detection. After addition of DA, a rapid colour change has been noted in colloids of nanoparticles. The substantial changes in absorbance and λ{sub max} in metal nanoparticles respect to DA concentration have been observed and formulated. This is one of the successive methods for trace level determination of DA and will be going to a significant material for designing biosensor to determine DA in real extracellular body fluids. - Highlights: • L-His functionalized Ag, Au and bimetallic Ag-Au nanoparticles were prepared and its properties were studied. • L-His based Ag, Au, Ag-Au nanoparticles have characterized by spectroscopy, XRD and microscopic studies. • Enhanced optical nature of nanoparticles delivers the best platform to develop a biosensor for DA detection. • For qualitative determination of dopamine, SPR of metal nanoparticles plays a major role in dopamine determination. • This basic finding can be utilized for further identification of imbalanced DA concentration in body fluids.

  19. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    Science.gov (United States)

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  20. Nuclear power plant fire protection: fire detection (subsystems study Task 2)

    International Nuclear Information System (INIS)

    Berry, D.L.

    1977-12-01

    This report examines the adequacy of fire detection in the context of nuclear power plant safety. Topics considered are: (1) establishing area detection requirements, (2) selecting specific detector types, (3) locating and spacing detectors, and (4) performing installation tests and maintenance. Based on a thorough review of fire detection codes and standards and fire detection literature, the report concludes that current design and regulatory guidelines alone are insufficient to ensure satisfactory fire detection system performance. To assure adequate fire detection, this report recommends the use of in-place testing of detectors under conditions expected to occur normally in areas being protected

  1. A Pilot Study of Pedestrians with Visual Impairments Detecting Traffic Gaps and Surges Containing Hybrid Vehicles

    Science.gov (United States)

    Emerson, Robert Wall; Naghshineh, Koorosh; Hapeman, Julie; Wiener, William

    2010-01-01

    The increasing number of hybrid and quiet internal combustion engine vehicles may impact the travel abilities of pedestrians who are blind. Pedestrians who rely on auditory cues for structuring their travel may face challenges in making crossing decisions in the presence of quiet vehicles. This article describes results of initial studies looking at the crossing decisions of pedestrians who are blind at an uncontrolled crossing (no traffic control) and a light controlled intersection. The presence of hybrid vehicles was a factor in each situation. At the uncontrolled crossing, Toyota hybrids were most difficult to detect but crossing decisions were made more often in small gaps ended by a Honda hybrid. These effects were seen only at speed under 20 mph. At the light controlled intersection, parallel surges of traffic were most difficult to detect when made up only of a Ford Escape hybrid. Results suggest that more controlled studies of vehicle characteristics impacting crossing decisions of pedestrians who are blind are warranted. PMID:21379367

  2. Experimental study on early detection of alloxan-induced pulmonary injury by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Awai, Kazuo; Fukuda, Hiroshi; Nakamura, Susumu; Fujikawa, Koichi; Utsumi, Toshio; Kajima, Toshio; Azuma, Kazuyoshi; Ito, Katsuhide.

    1995-01-01

    We studied the early detection of alloxan-induced pulmonary injury by magnetic resonance imaging in vivo. Permeability edema was induced in ten rats by intravenous injection of alloxan at 100 mg/Kg. T1-and T2-weighted images were acquired in five rats every 30 min for 120 min after alloxan injection. Five rats served as controls. The rats were sacrificed immediately after imaging and examined microscopically. CT images were also acquired in five rats every 30 min for 120 min after alloxan injection. Five rats served as controls. The rats were sacrificed immediately after imaging, and the wet-to-dry ratio of the lung was measured. In T1-weighted images, relative signal intensity from the lung with permeability edema rose from 30 min to 120 min, and was greater than that from normal lung every time. In T2-weighted images, there was no statistically significant difference in relative signal intensity of the lung between permeability edema and the control during 120 min. In CT images, there was also no statistically significant difference in lung density between permeability edema and the control during 120 min. There was no statistically significant difference in the wet-to-dry lung ratio between edematous lung and normal lung. In histological study, mild congestion and interstitial edema were observed in edematous lung. These results suggest the potential capability of MR imaging in detecting the early phase of permeability pulmonary edema. (author)

  3. A Longitudinal Study of Adenoma Detection Rate in Gastroenterology Fellowship Training.

    Science.gov (United States)

    Gianotti, Robert J; Oza, Sveta Shah; Tapper, Elliot B; Kothari, Darshan; Sheth, Sunil G

    2016-10-01

    Current guidelines suggest that a gastroenterology fellow in training needs to perform 140 colonoscopies to achieve competency. Data are limited regarding adenoma detection rate (ADR) in fellowship. To assess how fellow ADR correlates with number of colonoscopies performed. We performed a retrospective study examining consecutive colonoscopies performed by gastroenterology fellows. Fellow ADR before and after the 140 procedure benchmark was compared to colonoscopies performed by attending only with whom these fellows trained. A threshold for ideal procedure count was performed using ROC analysis. We analyzed 2021 average-risk colonoscopies performed by 10 gastroenterology fellows under the supervision of an attending physician. When fellows had performed 140 colonoscopies under attending supervision (p = 0.02). The ADR of fellows who had performed >140 colonoscopies under attending supervision was greater than that of attending-only colonoscopies (36 vs. 25 %, p 325 (male patients) and 539 (female patients) colonoscopies was determined to be ideal for achieving adequate ADR based on ROC analysis. Our data suggest that ADR increases after fellows perform >140 colonoscopies under attending supervision, and thereafter surpasses the ADR of attending-only colonoscopies. Some of the differences may be driven by detection of small adenomas. The findings of this study suggest that a higher threshold for number of colonoscopies performed under attending supervision may be needed to achieve adequate ADR during fellowship prior to independent practice.

  4. Study on the Spectrophotometric Detection of Free Fatty Acids in Palm Oil Utilizing Enzymatic Reactions

    Directory of Open Access Journals (Sweden)

    Nur Hidayah Azeman

    2015-07-01

    Full Text Available In this paper, a comprehensive study has been made on the detection of free fatty acids (FFAs in palm oil via an optical technique based on enzymatic aminolysis reactions. FFAs in crude palm oil (CPO were converted into fatty hydroxamic acids (FHAs in a biphasic lipid/aqueous medium in the presence of immobilized lipase. The colored compound formed after complexation between FHA and vanadium (V ion solution was proportional to the FFA content in the CPO samples and was analyzed using a spectrophotometric method. In order to develop a rapid detection system, the parameters involved in the aminolysis process were studied. The utilization of immobilized lipase as catalyst during the aminolysis process offers simplicity in the product isolation and the possibility of conducting the process under extreme reaction conditions. A good agreement was found between the developed method using immobilized Thermomyces lanuginose lipase as catalyst for the aminolysis process and the Malaysian Palm Oil Board (MPOB standard titration method (R2 = 0.9453.

  5. Real time deforestation detection using ann and satellite images the Amazon rainforest study case

    CERN Document Server

    Nunes Kehl, Thiago; Roberto Veronez, Maurício; Cesar Cazella, Silvio

    2015-01-01

    The foremost aim of the present study was the development of a tool to detect daily deforestation in the Amazon rainforest, using satellite images from the MODIS/TERRA sensor and Artificial Neural Networks. The developed tool provides parameterization of the configuration for the neural network training to enable us to select the best neural architecture to address the problem. The tool makes use of confusion matrices to determine the degree of success of the network. A spectrum-temporal analysis of the study area was done on 57 images from May 20 to July 15, 2003 using the trained neural network. The analysis enabled verification of quality of the implemented neural network classification and also aided in understanding the dynamics of deforestation in the Amazon rainforest, thereby highlighting the vast potential of neural networks for image classification. However, the complex task of detection of predatory actions at the beginning, i.e., generation of consistent alarms, instead of false alarms has not bee...

  6. A Feasibility Study on Detection of Insider Threats based on Human Bio-signals

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Young A; Yim, Man-Sung [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    The insider threat means that trusted workers in an organization might carry out harmful acts from the negligent use of classified data to potentially sabotage the workplace. Surveys and studies conducted over the last decade have consistently shown the critical nature of the insider threats problem, in both government and private sectors. The shortcomings of existing systems, such as mental self-assessment and peer review, are very subjective, biased-assessments and employed infrequently. To overcome these limitations, this study investigates the feasibility of detecting and predicting an insider threat by using human biodata, from smart wearable devices. This paper showed the feasibility of predicting and detecting insider threats using EEG, GSR and ECG signals. In the section 2.1, two research hypotheses were established to identify the significant difference on EEG, GSR and ECG signals when the subject decided bad action and is the placed in deceit situation. These hypotheses were tested using two kinds of pilot experiments in the form of input (stimulus) and output (checking response of physiological signals and reaction time)

  7. Comparative Study of Contour Detection Evaluation Criteria Based on Dissimilarity Measures

    Directory of Open Access Journals (Sweden)

    Bruno Emile

    2008-04-01

    Full Text Available We present in this article a comparative study of well-known supervised evaluation criteria that enable the quantification of the quality of contour detection algorithms. The tested criteria are often used or combined in the literature to create new ones. Though these criteria are classical ones, none comparison has been made, on a large amount of data, to understand their relative behaviors. The objective of this article is to overcome this lack using large test databases both in a synthetic and a real context allowing a comparison in various situations and application fields and consequently to start a general comparison which could be extended by any person interested in this topic. After a review of the most common criteria used for the quantification of the quality of contour detection algorithms, their respective performances are presented using synthetic segmentation results in order to show their performance relevance face to undersegmentation, oversegmentation, or situations combining these two perturbations. These criteria are then tested on natural images in order to process the diversity of the possible encountered situations. The used databases and the following study can constitute the ground works for any researcher who wants to confront a new criterion face to well-known ones.

  8. Contribution to the study of position sensitive detectors with high spatial resolution for thermal neutron detection

    International Nuclear Information System (INIS)

    Idrissi Fakhr-Eddine, Abdellah.

    1978-01-01

    With a view to improving the spatial resolution of the localization of thermal neutrons, the work covers four position sensitive detectors: - 800 cell multi-detectors (1 dimension), - linear 'Jeu de Jacquet' detectors (1 dimension) - Multi-detector XYP 128x128 (2 dimensions), - 'Jeu de Jacquet' detector with 2 dimensions. Mention is made of the various position finding methods known so far, as well as the reasons for selecting BF 3 as detector gas. A study is then made of the parameters of the multiwire chamber whose principle will form the basis of most of the position detecting appliances subsequently dealt with. Finally, a description is given of the detection tests of the thermal neutrons in the multiwire chamber depending on the pressure, a parameter that greatly affects the accuracy of the position finding. The single dimension position tests on two kinds of appliance, the 800 cell multi-detector for the wide angle diffraction studies, and the linear 'Jeu de Jacquet' detector designed for small angle diffraction are mentioned. A description is then given of two position appliances with two dimensions; the multi-detector XYP 128x128 and the two dimensional 'Jeu de Jacquet' detector. In the case of this latter detector, only the hoped for characteristics are indicated [fr

  9. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study.

    Science.gov (United States)

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-07-07

    To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ(2) test. A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the negative predictive

  10. Using linked hospitalisation data to detect nursing sensitive outcomes: a retrospective cohort study.

    Science.gov (United States)

    Schreuders, Louise Winton; Bremner, Alexandra P; Geelhoed, Elizabeth; Finn, Judith

    2014-03-01

    Nursing sensitive outcomes are adverse patient health outcomes that have been shown to be associated with nursing care. Researchers have developed specific algorithms to identify nursing sensitive outcomes using administrative data sources, although contention still surrounds the ability to adjust for pre-existing conditions. Existing nursing sensitive outcome detection methods could be improved by using look-back periods that incorporate relevant health information from patient's previous hospitalisations. Retrospective cohort study at three tertiary metropolitan hospitals in Perth, Western Australia. The objective of this research was to explore the effect of using linked hospitalisation data on estimated incidence rates of eleven adverse nursing sensitive outcomes by retrospectively extending the timeframe during which relevant patient disease information may be identified. The research also explored whether patient demographics and/or the characteristics of their hospitalisations were associated with nursing sensitive outcomes. During the 5 year study period there were 356,948 hospitalisation episodes involving 189,240 patients for a total of 2,493,654 inpatient days at the three tertiary metropolitan hospitals. There was a reduction in estimated rates for all nursing sensitive outcomes when a look-back period was applied to identify relevant health information from earlier hospitalisations within the preceding 2 years. Survival analysis demonstrates that the majority of relevant patient disease information is identified within approximately 2 years of the baseline nursing sensitive outcomes hospitalisation. Compared to patients without, patients with nursing sensitive outcomes were significantly more likely to be older (70 versus 58 years), female, have Charleson comorbidities, be direct transfers from another hospital, have a longer inpatient stay and spend time in intensive care units (p≤0.001). The results of this research suggest that nursing sensitive

  11. Outlier detection by robust Mahalanobis distance in geological data obtained by INAA to provenance studies

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Jose O. dos, E-mail: osmansantos@ig.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Sergipe (IFS), Lagarto, SE (Brazil); Munita, Casimiro S., E-mail: camunita@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Soares, Emilio A.A., E-mail: easoares@ufan.edu.br [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil). Dept. de Geociencias

    2013-07-01

    The detection of outlier in geochemical studies is one of the main difficulties in the interpretation of dataset because they can disturb the statistical method. The search for outliers in geochemical studies is usually based in the Mahalanobis distance (MD), since points in multivariate space that are a distance larger the some predetermined values from center of the data are considered outliers. However, the MD is very sensitive to the presence of discrepant samples. Many robust estimators for location and covariance have been introduced in the literature, such as Minimum Covariance Determinant (MCD) estimator. When MCD estimators are used to calculate the MD leads to the so-called Robust Mahalanobis Distance (RD). In this context, in this work RD was used to detect outliers in geological study of samples collected from confluence of Negro and Solimoes rivers. The purpose of this study was to study the contributions of the sediments deposited by the Solimoes and Negro rivers in the filling of the tectonic depressions at Parana do Ariau. For that 113 samples were analyzed by Instrumental Neutron Activation Analysis (INAA) in which were determined the concentration of As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, U, Yb, Ta, Tb, Th and Zn. In the dataset was possible to construct the ellipse corresponding to robust Mahalanobis distance for each group of samples. The samples found outside of the tolerance ellipse were considered an outlier. The results showed that Robust Mahalanobis Distance was more appropriate for the identification of the outliers, once it is a more restrictive method. (author)

  12. Outlier detection by robust Mahalanobis distance in geological data obtained by INAA to provenance studies

    International Nuclear Information System (INIS)

    Santos, Jose O. dos; Munita, Casimiro S.; Soares, Emilio A.A.

    2013-01-01

    The detection of outlier in geochemical studies is one of the main difficulties in the interpretation of dataset because they can disturb the statistical method. The search for outliers in geochemical studies is usually based in the Mahalanobis distance (MD), since points in multivariate space that are a distance larger the some predetermined values from center of the data are considered outliers. However, the MD is very sensitive to the presence of discrepant samples. Many robust estimators for location and covariance have been introduced in the literature, such as Minimum Covariance Determinant (MCD) estimator. When MCD estimators are used to calculate the MD leads to the so-called Robust Mahalanobis Distance (RD). In this context, in this work RD was used to detect outliers in geological study of samples collected from confluence of Negro and Solimoes rivers. The purpose of this study was to study the contributions of the sediments deposited by the Solimoes and Negro rivers in the filling of the tectonic depressions at Parana do Ariau. For that 113 samples were analyzed by Instrumental Neutron Activation Analysis (INAA) in which were determined the concentration of As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, U, Yb, Ta, Tb, Th and Zn. In the dataset was possible to construct the ellipse corresponding to robust Mahalanobis distance for each group of samples. The samples found outside of the tolerance ellipse were considered an outlier. The results showed that Robust Mahalanobis Distance was more appropriate for the identification of the outliers, once it is a more restrictive method. (author)

  13. Usual normalization strategies for gene expression studies impair the detection and analysis of circadian patterns.

    Science.gov (United States)

    Figueredo, Diego de Siqueira; Barbosa, Mayara Rodrigues; Coimbra, Daniel Gomes; Dos Santos, José Luiz Araújo; Costa, Ellyda Fernanda Lopes; Koike, Bruna Del Vechio; Alexandre Moreira, Magna Suzana; de Andrade, Tiago Gomes

    2018-03-01

    Recent studies have shown that transcriptomes from different tissues present circadian oscillations. Therefore, the endogenous variation of total RNA should be considered as a potential bias in circadian studies of gene expression. However, normalization strategies generally include the equalization of total RNA concentration between samples prior to cDNA synthesis. Moreover, endogenous housekeeping genes (HKGs) frequently used for data normalization may exhibit circadian variation and distort experimental results if not detected or considered. In this study, we controlled experimental conditions from the amount of initial brain tissue samples through extraction steps, cDNA synthesis, and quantitative real time PCR (qPCR) to demonstrate a circadian oscillation of total RNA concentration. We also identified that the normalization of the RNA's yield affected the rhythmic profiles of different genes, including Per1-2 and Bmal1. Five widely used HKGs (Actb, Eif2a, Gapdh, Hprt1, and B2m) also presented rhythmic variations not detected by geNorm algorithm. In addition, the analysis of exogenous microRNAs (Cel-miR-54 and Cel-miR-39) spiked during RNA extraction suggests that the yield was affected by total RNA concentration, which may impact circadian studies of small RNAs. The results indicate that the approach of tissue normalization without total RNA equalization prior to cDNA synthesis can avoid bias from endogenous broad variations in transcript levels. Also, the circadian analysis of 2 -Cycle threshold (Ct) data, without HKGs, may be an alternative for chronobiological studies under controlled experimental conditions.

  14. Experimental imaging study of 99Tcm-ciprofloxacin in detection of infection

    International Nuclear Information System (INIS)

    He Wei; Chen Shaoliang; Mao Jinlei; Jiang Maosong

    2008-01-01

    Objective: Most of the current imaging agents fox inflammatory and(or) infectious dis- eases are not specific enough. It was studied that using ciprofloxacin(an antibiotics)labeled with 99 Tc m for a novel imaging agent detected inflammatory and(or) infectious foci in vivo. Methods: In this investigation, the biological properties were evaluated by pharmacologic experiments. The end points of this study were two. One was to study the biodistribution of 99 Tc m labeled ciprofloxacin (an antibiotics)in vivo. The other was to understand the potential role of 99 Tc m -ciprofloxacin in detecting inflammatory and(or) infectious foci in rabbit models. The biodistribution of 99 Tc m -ciprofloxacin was studied in mice models. Scintigraphy of 99 Tc m -ciprofloxacin was performed in rabbit models. Results: The labeling rate was over 90%. The dissociation of 99 Tc m ciprofloxacin was minimal within 8 h at room temperature. After intravenous injection, rapid plasma clearance and renal clearance were observed. Kidney, liver and spleen were the target organs for the accumulation of injected 99 Tc m -ciprofloxacin. In the infectious rabbit models (n=3), accumulation of 99 Tc m -ciprofloxacin was found at the infective lesion (left thigh). The dynamic study showed that the optimal acquisition time for 99 Tc m ciprofloxacin imaging was at 3 h after injection. Moreover, images could still be positive at 24 h after injection. Notably, little 99 Tc m -ciprofloxacin accumulation was observed at the inflammation foci in above rabbit models. Conclusion: 99 Tc m -ciprofloxacin could be a potential imaging agent for infectious rather than inflammatory disease in vivo in the future. (authors)

  15. Applications of a single-molecule detection in early disease diagnosis and enzymatic reaction study

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jiangwei [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    Various single-molecule techniques were utilized for ultra-sensitive early diagnosis of viral DNA and antigen and basic mechanism study of enzymatic reactions. DNA of human papilloma virus (HPV) served as the screening target in a flow system. Alexa Fluor 532 (AF532) labeled single-stranded DNA probes were hybridized to the target HPV-16 DNA in solution. The individual hybridized molecules were imaged with an intensified charge-coupled device (ICCD) in two ways. In the single-color mode, target molecules were detected via fluorescence from hybridized probes only. This system could detect HPV-16 DNA in the presence of human genomic DNA down to 0.7 copy/cell and had a linear dynamic range of over 6 orders of magnitude. In the dual-color mode, fluorescence resonance energy transfer (FRET) was employed to achieve zero false-positive count. We also showed that DNA extracts from Pap test specimens did not interfere with the system. A surface-based method was used to improve the throughput of the flow system. HPV-16 DNA was hybridized to probes on a glass surface and detected with a total internal reflection fluorescence (TIRF) microscope. In the single-probe mode, the whole genome and target DNA were fluorescently labeled before hybridization, and the detection limit is similar to the flow system. In the dual-probe mode, a second probe was introduced. The linear dynamic range covers 1.44-7000 copies/cell, which is typical of early infection to near-cancer stages. The dual-probe method was tested with a crudely prepared sample. Even with reduced hybridization efficiency caused by the interference of cellular materials, we were still able to differentiate infected cells from healthy cells. Detection and quantification of viral antigen with a novel single-molecule immunosorbent assay (SMISA) was achieved. Antigen from human immunodeficiency virus type 1(HIV-1) was chosen to be the target in this study. The target was sandwiched between a monoclonal capture antibody and a

  16. A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection

    International Nuclear Information System (INIS)

    Liu, Yang; Zhang, Yingchun

    2014-01-01

    Magnetic resonance electrical impedance tomography (MREIT) is an imaging technique that reconstructs the conductivity distribution inside the subject using magnetic flux density or current density measurements acquired by a magnetic resonance imaging system. Since the primary prostate cancer diagnostic method, prostate biopsy, has limited accuracy in cancer diagnosis and malignant tissues have shown significantly different electrical properties from normal or benign tissues, MREIT has potential application in prostate cancer detection. The feasibility of utilizing MREIT in detecting prostate cancer was evaluated via a series of well-designed computer simulations in the present study. MREIT techniques with three different electrode configurations (external, trans-rectal, and trans-urethral electrode arrays) and two different reconstruction algorithms (J-substitution algorithm and harmonic B z  algorithm) were successfully developed. The performance of different MREIT techniques were evaluated and compared based on the imaging accuracy of the reconstructed conductivity distribution in the prostate. Without the presence of noise, the external MREIT achieves a better imaging accuracy than the two endo-MREIT (trans-rectal and trans-urethral) techniques, while the trans-urethral MREIT achieves the best imaging accuracy in noisy environments. We also found that the J-substitution reconstruction algorithm consistently offered better imaging accuracy than the harmonic B z  algorithm. When Gaussian distributed random noise with a standard deviation of 0.25 nT was added, the relative errors (RE) between the reconstructed and target conductivity distributions inside the prostate were observed to be 14.18% and 17.35% by the trans-urethral MREIT with the J-substitution and harmonic B z  algorithms respectively. The lower REs of 9.64% and 11.17% were achieved respectively when the standard deviation of noise was reduced to 0.05 nT. The simulation results demonstrate the

  17. CT and pathologic studies in detecting hepatic involvement of malignant lymphoma

    International Nuclear Information System (INIS)

    Okazaki, Atsushi; Niibe, Hideo; Mitsuhashi, Norio

    1985-01-01

    In order to determine the value of CT in detecting lymphomatous involvement of the liver, 57 autopsied cases (48 cases of non-Hodgkin lymphoma and 9 of Hodgkin's disease) were analyzed in detail. Additionally, 90 recent cases of abdominal CT with liver study in the initial staging were reviewed and 6 cases in which the liver had been examined within 2 weeks before autopsy were compared for macroscopic and pathologic findings. The following results were obtained. 1) Autopsy findings in 57 cases of malignant lymphoma. (1) Hepatic involvement was demonstrated in 56% of the patients with non-Hodgkin lymphoma and in 67% of those with Hodgkin's disease. (2) Of these patients with hepatic involvement, intrahepatic nodular lesions over 1.0cm in diameter were macroscopically identified in 22% of the cases of non-Hodgkin lymphoma and 33% of those with Hodgkin's disease. (3) Lymphomatous involvements were seen in many organs in the cases of hepatic involvement. 2) CT examinations of 90 cases for the initial staging showed no significant abnormality in the liver or spleen. 3) Of the 6 cases in which the liver was examined by CT within about 2 weeks before autopsy, lymphomatous involvemet was pathologically diagnosed in 5. Of these, only one having multiple nodules larger than the tip of a thumb was correctly diagnosed by CT. 4) Hepatic involvement of lymphoma was thought to be the end stage, and minimal or early disease was detected in the region of Glisson's capsule. The above findings indicate that early hepatic involvement is not likely to be detected by CT at the present time. (author)

  18. Studies on Microbiological and Biological Methods for Detection of Irradiated Food

    International Nuclear Information System (INIS)

    Ibrahim, H.M.A.

    2013-01-01

    The main aim of this study is to evaluate a microbiological and biological methods used for the detection of irradiated foods in Egypt. The microbiological methods included were shift in microflora load and direct epifluroescent filter technique compared with aerobic plate count (DEFT/APC), while the biological method was DNA comet assay. The selected foods were black, strawberry, fresh-and frozen-de boned chicken. The samples of these foods were exposed to different doses of gamma radiation according to the purpose of irradiation for each food. The results indicated that the characteristics of microbial population of all irradiated samples have been changed. The very lower count of viable bacterial count (APC) and mold and yeasts counts in the samples than the reported normal count as well as the absence of Gram- negative bacteria and Enterobacteriaceae group from these samples could be used as an indication for radiation treatment of these foods. The large difference between microbial counts obtained by DEFT test and that obtained by APC test could also be used for screening radiation treatment of these foods. Photographic and image analysis of DNA comet assay showed that irradiation of these foods caused damage to the food cells DNA (fragmentation) at different levels according to the doses used and kind of foods. This DNA damage can be followed or described by DNA comet assay test. On the basis of comet assay, the discrimination between unirradiated and irradiated food samples was very possible. In general the results showed that DEFT/APC method had the potential to detect irradiated food samples either at zero time of storage or throughout the storage period post- irradiation. DNA comet assay as a rapid, simple and inexpensive screening test approved to be successful for detection of irradiated food samples under investigation. Determination of rough applied irradiation dose is possible if photographic analysis is combined with image analysis

  19. Study of a proportional chamber for the detection of muons in the CELLO experiment

    International Nuclear Information System (INIS)

    Durand, Alain.

    1978-01-01

    The physics of e + e - interactions that the CELLO experiment is proposing to do requires good μ detection. For this, the prototype of a wire type proportional chamber with integrated logical system read-out is under study. The various phenomena that govern the working of a wire type proportional chamber are recalled first of all. Section II deals with the various working and read-out modes. Section III is devoted to the description of the method chosen and its advantages. In Sections IV and V, the two more specifically studied read-out methods are presented and it is shown that the read-out method by delay line proves to be much more delicate to use than the integrated electronic method finally selected [fr

  20. Can Remote Sensing Detect Aquifer Characteristics?: A Case Study in the Guarani Aquifer System

    Science.gov (United States)

    Richey, A. S.; Thomas, B.; Famiglietti, J. S.

    2013-12-01

    Global water supply resiliency depends on groundwater, especially regions threatened by population growth and climate change. Aquifer characteristics, even as basic as confined versus unconfined, are necessary to prescribe regulations to sustainably manage groundwater supplies. A significant barrier to sustainable groundwater management exists in the difficulties associated with mapping groundwater resources and characteristics at a large spatial scale. This study addresses this challenge by investigating if remote sensing, including with NASA's Gravity Recovery and Climate Experiment (GRACE), can detect and quantify key aquifer parameters and characteristics. We explore this through a case study in the Guarani Aquifer System (GAS) of South America, validating our remote sensing-based findings against the best available regional estimates. The use of remote sensing to advance the understanding of large aquifers is beneficial to sustainable groundwater management, especially in a trans-boundary system, where consistent information exchange can occur within hydrologic boundaries instead of political boundaries.

  1. Can DMCO Detect Visual Field Loss in Neurological Patients? A Secondary Validation Study

    DEFF Research Database (Denmark)

    Olsen, Ane Sophie; Steensberg, Alvilda Thougaard; la Cour, Morten

    2017-01-01

    Unrecognized visual field loss is caused by a range of blinding eye conditions as well as serious brain diseases. The commonest cause of asymptomatic visual field loss is glaucoma. No screening tools have been proven cost-effective. Damato Multifixation Campimetry Online (DMCO), an inexpensive...... online test, has been evaluated as a future cost-beneficial tool to detect glaucoma. To further validate DMCO, this study aimed to test DMCO in a preselected population with neurological visual field loss. Methods : The study design was an evaluation of a diagnostic test. Patients were included...... if they had undergone surgery for epilepsy during 2011-2014, resulting in visual field loss. They were examined with DMCO and results were compared with those obtained with the Humphrey Field Analyzer (30:2 SITA-Fast). DMCO sensitivity and specificity were estimated with 95% confidence intervals. Results...

  2. Detection of alpha particles by means of zinc sulphide screens. Study of their characteristics

    International Nuclear Information System (INIS)

    Gaeta, R.; Manero, F.

    1959-01-01

    A method of SZn(Ag) screens preparation in order to detect alpha particles is described. The behaviour of the luminophore in a scintillometer is primarily studied and followed by experimental methods in the preparation of screens with the specific qualities required. A sedimentation technic of SZn(Ag) deposition has been employed, and followed by pressing in hot. The variation of impulse size with the massif thickness of luminophore has been studied, and found a maximum value for 6,5 mg/cm 2 in unpressed screens and 6 mg/cm 2 in the pressed ones. The plateau curves present flat areas till 450 volts. The background in source absence is below 0.5 impulse/minute. (Author) 19 refs

  3. Study of the photo-detection efficiency of FBK High-Density silicon photomultipliers

    International Nuclear Information System (INIS)

    Zappalà, G.; Regazzoni, V.; Acerbi, F.; Ferri, A.; Gola, A.; Paternoster, G.; Zorzi, N.; Piemonte, C.

    2016-01-01

    This work presents a study of the factors contributing to the Photo-Detection Efficiency of Silicon Photomultipliers (SiPMs): Quantum Efficiency, Triggering Probability and Fill Factor. Two different SiPM High-Density technologies are tested, NUV-HD, based on n-on-p junction, and RGB-HD, based on p-on-n junction, developed at FBK, Trento. The quantum efficiency was measured on photodiodes produced along with the SiPMs. The triggering probability, as a function of wavelength and bias voltage, was measured on circular Single Photon Avalanche Diodes (SPADs) with 100% fill factor. Square SPADs, having the same layout of single SiPM cells, were studied to measure the effective fill factor and compare it to the nominal value. The comparison of the circular and square SPADs allows to get the transition region size between the effective active area of the cell and the one defined by the layout.

  4. A study on the diagnosis for power transformer by ultrasonic wave detection(2)

    International Nuclear Information System (INIS)

    Lee, Sang Guk; Gil Doo Song

    2003-01-01

    The objectives of this study is to develop a device which could diagnose periodically the degradation of power transformer using ultrasonic signal through ultrasonic transducer attached surface of power transformer. And also it makes possible to reduce power failure time due to the power transformer fault and makes power system more reliable. Ultrasonic diagnostic device for power transformer was developed through this study. The developed device will contributed to early detection of fault and its location in the power transformer while it is operated, and also to extension of transformer life cycle, localization of this device will be reduced it's cost down compared with off shore. This device consisted of a new diagnostic algorithm is well suited for the power transformer which could found out some fault during the operation of on line monitoring system. This system could be extended to the general industrial plant utilizing the accumulated diagnostic technique.

  5. A study on the diagnosis for power transformer by Ultrasonic wave detection (2)

    International Nuclear Information System (INIS)

    Lee, Sang Guk; Gil, Doo Song

    2003-01-01

    The objectives of this study is to develop a device which could diagnosis periodically the degradation of power transformer using ultrasonic signal through ultrasonic transducer attached surface of power transformer. And also it makes possible to reduce power failure time due to the power transformer fault and makes power system more reliable. Ultrasonic diagnostic device for power transformer was developed through this study. The developed device will contributed to early detection of fault and its location in the power transformer while it is operated, and also to extension of transformer life cycle, localization of this device will be reduced it's cost down compared with off shore. This device consisted of a new diagnostic algorithm is well suited for the power transformer which could found out some fault during the operation of on line monitoring system. This system could be extended to the general industrial plant utilizing the accumulated diagnostic technique.

  6. A pilot study on the use of optical spectroscopy to detection of liver fibrosis

    International Nuclear Information System (INIS)

    Fabila, A; La Rosa, J. de; Stolik, S.; Escobedo, C.; Suarez Alvarez, K.; Lopez Navarrete, G.

    2012-01-01

    In this paper we present the preliminary study to evaluate the use of optical spectroscopy as a tool to detect liver fibrosis. In vivo fluorescence and diffuse reflectance spectra were acquired from male rats in which fibrosis were induced by means of carbon tetrachloride. Spectral measurements were obtained using a portable system with an excitation source of 365 nm and a fiber-optic probe. The livers from rats with fibrosis showed an increase in fluorescence and diffuse reflectance intensity when compared to normal liver tissue. A support vector machine discrimination algorithm based on fluorescence and diffuse reflectance intensities at 493 and 365 nm was developed. This algorithm yields a sensitivity and specificity of 88% and 94%, respectively, in differentiating fibrotic liver from normal liver tissue. the results obtained in this study suggest that optical spectroscopy could be worthy of further exploration in patients. (Author)

  7. A detailed study of the generation of optically detectable watermarks using the logistic map

    International Nuclear Information System (INIS)

    Mooney, Aidan; Keating, John G.; Heffernan, Daniel M.

    2006-01-01

    A digital watermark is a visible, or preferably invisible, identification code that is permanently embedded in digital media, to prove owner authentication and provide protection for documents. Given the interest in watermark generation using chaotic functions a detailed study of one chaotic function for this purpose is performed. In this paper, we present an approach for the generation of watermarks using the logistic map. Using this function, in conjunction with seed management, it is possible to generate chaotic sequences that may be used to create highpass or lowpass digital watermarks. In this paper we provide a detailed study on the generation of optically detectable watermarks and we provide some guidelines on successful chaotic watermark generation using the logistic map, and show using a recently published scheme, how care must be taken in the selection of the function seed

  8. A Study of Storage Ring Requirements for an Explosive Detection System Using NRA Method

    CERN Document Server

    Wang, Tai-Sen

    2005-01-01

    The technical feasibility of an explosives detection system based on the nuclear resonance absorption (NRA) of gamma rays in nitrogen-rich materials was demonstrated at Los Alamos National Laboratory (LANL) in 1993 by using an RFQ proton accelerator and a tomographic imaging prototype.* The study is being continued recently to examine deployment of such an active interrogation system in realistic scenarios. The approach is to use a cyclotron and electron-cooling-equipped storage rings(s) to provide the high quality and high current proton beam needed in a practical application. In this work, we investigate the storage ring requirements for a variant of the airport luggage inspection system considered in the earlier LANL experiments. Estimations are carried out based on the required inspection throughput, the gamma ray yield, the proton beam emittance growth due to scattering with the photon-production target, beam current limit in the storage ring, and the electron cooling rate. Studies using scaling and reas...

  9. Baseline Face Detection, Head Pose Estimation, and Coarse Direction Detection for Facial Data in the SHRP2 Naturalistic Driving Study

    Energy Technology Data Exchange (ETDEWEB)

    Paone, Jeffrey R [ORNL; Bolme, David S [ORNL; Ferrell, Regina Kay [ORNL; Aykac, Deniz [ORNL; Karnowski, Thomas Paul [ORNL

    2015-01-01

    Keeping a driver focused on the road is one of the most critical steps in insuring the safe operation of a vehicle. The Strategic Highway Research Program 2 (SHRP2) has over 3,100 recorded videos of volunteer drivers during a period of 2 years. This extensive naturalistic driving study (NDS) contains over one million hours of video and associated data that could aid safety researchers in understanding where the driver s attention is focused. Manual analysis of this data is infeasible, therefore efforts are underway to develop automated feature extraction algorithms to process and characterize the data. The real-world nature, volume, and acquisition conditions are unmatched in the transportation community, but there are also challenges because the data has relatively low resolution, high compression rates, and differing illumination conditions. A smaller dataset, the head pose validation study, is available which used the same recording equipment as SHRP2 but is more easily accessible with less privacy constraints. In this work we report initial head pose accuracy using commercial and open source face pose estimation algorithms on the head pose validation data set.

  10. Optically Detected Magnetic Resonance Studies on π-conjugated semiconductor systems

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Ying [Iowa State Univ., Ames, IA (United States)

    2011-01-01

    Optically Detected Magnetic Resonance (ODMR) techniques were used to investigate the dynamics of excitons and charge carriers in π-conjugated organic semiconductors. Degradation behavior of the negative spin-1/2 electroluminescence-detected magnetic resonance (ELDMR) was observed in Alq3 devices. The increase in the resonance amplitude implies an increasing bipolaron formation during degradation, which might be the result of growth of charge traps in the device. The same behavior of the negative spin-1/2 ELDMR was observed in 2wt% Rubrene doped Tris(8-hydroxyquinolinato)aluminium (Alq3) devices. However, with increasing injection current, a positive spin-1/2 ELDMR, together with positive spin 1 triplet powder patterns at ΔmS=±1 and ΔmS=±2, emerges. Due to the similarities in the frequency dependences of single and double modulated ELDMR and the photoluminescence-detected magnetic resonance (PLDMR) results in poly[2-methoxy-5-(2 -ethyl-hexyloxy)-1,4-phenyl ene vinylene] (MEH-PPV) films, the mechanism for this positive spin-1/2 ELDMR was assigned to enhanced triplet-polaron quenching under resonance conditions. The ELDMR in rubrene doped Alq3 devices provides a path to investigate charge distribution in the device under operational conditions. Combining the results of several devices with different carrier blocking properties and the results from transient EL, it was concluded trions not only exist near buffer layer but also exist in the electron transport layer. This TPQ model can also be used to explain the positive spin-1/2 PLDMR in poly(3-hexylthiophene) (P3HT) films at low temperature and in MEH-PPV films at various temperatures up to room temperature. Through quantitative analysis, TE-polaron quenching (TPQ) model is shown having the ability to explain most behaviors of the positive spin-1/2 resonance. Photocurrent detected magnetic resonance (PCDMR) studies on MEH-PPV devices revealed a novel transient resonance signal. The signal

  11. Sacroiliitis detected by bone scintiscanning: a clinical, radiological, and scintigraphic follow-up study

    International Nuclear Information System (INIS)

    Chalmers, I.M.; Lentle, B.C.; Percy, J.S.; Russell, A.S.

    1979-01-01

    Twenty-four patients had abnormal sacroiliac joints detected by quantitative sacroiliac scintigraphy but no radiological evidence of sacroiliitis on original investigation. They were studied again after intervals of 12 to 36 months. Four patients developed radiological change. Two young, HLA B27-positive men had undoubted ankylosing spondylitis, and a young woman had possible ankylosing spondylitis. A middle-aged man had changes that could be attributed to post-traumatic osteoarthrosis. Of the remaining 20 cases, 15 had symptoms and signs suggestive of inflammatory disease of the axial skeleton (and peripheral arthropathy in 5 cases). The sexes were affected equally (8 females, 7 Males), and only 2 of the 15 were B27-positive. The response to anti-inflammatory medication was generally good to excellent, and scintiscans tended to improve. Of the remaining 5 patients, 3 had mechanical or traumatic problems, and in 2 there was no explanation for the abnormal sacroiliac scintiscan. It is concluded that quantitative sacroiliac scintigraphy may detect ankylosing spondylitis prior to the development of radiological change and that it can identify an organic basis for backache in patients with a spondylitis-like syndrome. The clinical circumstances must be taken into account, as scintigraphic abnormalities are not diagnostic of any specific disease entity. (author)

  12. Study of mitochondria D-loop gene to detect the heterogeneity of gemak in Turnicidae family

    Science.gov (United States)

    Setiati, N.; Partaya

    2018-03-01

    As a part of life biodiversity, birds in Turnicidae family should be preserved from the extinction and its type heterogeneity decline. One effort for giving the strategic base of plasma nutfah conservation is through genetic heterogeneity study. The aim of the research is to analyze D-loop gen from DNA mitochondria of gemak bird in Turnicidae family molecularly. From the result of the analysis, it may be known the genetic heterogeneity of gemak bird based on the sequence of D-loop gen. The collection of both types of gemak of Turnicidae family is still easy since we can find them in ricefield area after harvest particularly for Gemakloreng (Turnix sylvatica), it means while gemak tegalan (Turnixsusciator) is getting difficult to find. Based on the above DNA quantification standard, the blood sample of Gemak in this research is mostly grouped into pure blood (ranges from 1,63 – 1,90), and it deserves to be used for PCR analysis. The sequencing analysis has not detected the sequence of nucleotide completely. However, it indicates sequence polymorphism of base as the arranger of D-loop gen. D-loop gen may identify genetic heterogeneity of gemak bird of Turnicidae family, but it is necessary to perform further sequencing analysis with PCR-RFLP technique. This complete nucleotide sequence is obtained and easy to detect after being cut restriction enzyme.

  13. Biomarker Detection in Association Studies: Modeling SNPs Simultaneously via Logistic ANOVA

    KAUST Repository

    Jung, Yoonsuh; Huang, Jianhua Z.; Hu, Jianhua

    2014-01-01

    In genome-wide association studies, the primary task is to detect biomarkers in the form of Single Nucleotide Polymorphisms (SNPs) that have nontrivial associations with a disease phenotype and some other important clinical/environmental factors. However, the extremely large number of SNPs comparing to the sample size inhibits application of classical methods such as the multiple logistic regression. Currently the most commonly used approach is still to analyze one SNP at a time. In this paper, we propose to consider the genotypes of the SNPs simultaneously via a logistic analysis of variance (ANOVA) model, which expresses the logit transformed mean of SNP genotypes as the summation of the SNP effects, effects of the disease phenotype and/or other clinical variables, and the interaction effects. We use a reduced-rank representation of the interaction-effect matrix for dimensionality reduction, and employ the L 1-penalty in a penalized likelihood framework to filter out the SNPs that have no associations. We develop a Majorization-Minimization algorithm for computational implementation. In addition, we propose a modified BIC criterion to select the penalty parameters and determine the rank number. The proposed method is applied to a Multiple Sclerosis data set and simulated data sets and shows promise in biomarker detection.

  14. Transcranial vibro-acoustography can detect traumatic brain injury, in-vivo: Preliminary studies.

    Science.gov (United States)

    Suarez, Martin W; Dever, David D; Gu, Xiaohan; Ray Illian, P; McClintic, Abbi M; Mehic, Edin; Mourad, Pierre D

    2015-08-01

    Vibro-acoustography (VA) uses two or more beams of confocal ultrasound to generate local vibrations within their target tissue through induction of a time-dependent radiation force whose frequency equals that of the difference of the applied frequencies. While VA has proven effective for assaying the mechanical properties of clinically relevant tissue such as breast lesions and tissue calcifications, its application to brain remains unexplored. Here we investigate the ability of VA to detect acute and focal traumatic brain injury (TBI) in-vivo through the use of transcranially delivered high-frequency (2 MHz) diagnostic focused ultrasound to rat brain capable of generating measurable low-frequency (200-270 kHz) acoustic emissions from outside of the brain. We applied VA to acute sham-control and TBI model rats (sham N=6; TBI N=6) and observed that acoustic emissions, captured away from the site of TBI, had lower amplitudes for TBI as compared to sham-TBI animals. The sensitivity of VA to acute brain damage at frequencies currently transmittable across human skulls, as demonstrated in this preliminary study, supports the possibility that the VA methodology may one day serve as a technique for detecting TBI. Copyright © 2015. Published by Elsevier B.V.

  15. Single Sensor Gait Analysis to Detect Diabetic Peripheral Neuropathy: A Proof of Principle Study

    Directory of Open Access Journals (Sweden)

    Patrick Esser

    2018-01-01

    Full Text Available This study explored the potential utility of gait analysis using a single sensor unit (inertial measurement unit [IMU] as a simple tool to detect peripheral neuropathy in people with diabetes. Seventeen people (14 men aged 63±9 years (mean±SD with diabetic peripheral neuropathy performed a 10-m walk test instrumented with an IMU on the lower back. Compared to a reference healthy control data set (matched by gender, age, and body mass index both spatiotemporal and gait control variables were different between groups, with walking speed, step time, and SDa (gait control parameter demonstrating good discriminatory power (receiver operating characteristic area under the curve >0.8. These results provide a proof of principle of this relatively simple approach which, when applied in clinical practice, can detect a signal from those with known diabetes peripheral neuropathy. The technology has the potential to be used both routinely in the clinic and for tele-health applications. Further research should focus on investigating its efficacy as an early indicator of or effectiveness of the management of peripheral neuropathy. This could support the development of interventions to prevent complications such as foot ulceration or Charcot's foot.

  16. Single Sensor Gait Analysis to Detect Diabetic Peripheral Neuropathy: A Proof of Principle Study.

    Science.gov (United States)

    Esser, Patrick; Collett, Johnny; Maynard, Kevin; Steins, Dax; Hillier, Angela; Buckingham, Jodie; Tan, Garry D; King, Laurie; Dawes, Helen

    2018-02-01

    This study explored the potential utility of gait analysis using a single sensor unit (inertial measurement unit [IMU]) as a simple tool to detect peripheral neuropathy in people with diabetes. Seventeen people (14 men) aged 63±9 years (mean±SD) with diabetic peripheral neuropathy performed a 10-m walk test instrumented with an IMU on the lower back. Compared to a reference healthy control data set (matched by gender, age, and body mass index) both spatiotemporal and gait control variables were different between groups, with walking speed, step time, and SDa (gait control parameter) demonstrating good discriminatory power (receiver operating characteristic area under the curve >0.8). These results provide a proof of principle of this relatively simple approach which, when applied in clinical practice, can detect a signal from those with known diabetes peripheral neuropathy. The technology has the potential to be used both routinely in the clinic and for tele-health applications. Further research should focus on investigating its efficacy as an early indicator of or effectiveness of the management of peripheral neuropathy. This could support the development of interventions to prevent complications such as foot ulceration or Charcot's foot. Copyright © 2018 Korean Diabetes Association.

  17. Biomarker Detection in Association Studies: Modeling SNPs Simultaneously via Logistic ANOVA

    KAUST Repository

    Jung, Yoonsuh

    2014-10-02

    In genome-wide association studies, the primary task is to detect biomarkers in the form of Single Nucleotide Polymorphisms (SNPs) that have nontrivial associations with a disease phenotype and some other important clinical/environmental factors. However, the extremely large number of SNPs comparing to the sample size inhibits application of classical methods such as the multiple logistic regression. Currently the most commonly used approach is still to analyze one SNP at a time. In this paper, we propose to consider the genotypes of the SNPs simultaneously via a logistic analysis of variance (ANOVA) model, which expresses the logit transformed mean of SNP genotypes as the summation of the SNP effects, effects of the disease phenotype and/or other clinical variables, and the interaction effects. We use a reduced-rank representation of the interaction-effect matrix for dimensionality reduction, and employ the L 1-penalty in a penalized likelihood framework to filter out the SNPs that have no associations. We develop a Majorization-Minimization algorithm for computational implementation. In addition, we propose a modified BIC criterion to select the penalty parameters and determine the rank number. The proposed method is applied to a Multiple Sclerosis data set and simulated data sets and shows promise in biomarker detection.

  18. A Study for Parametric Morphogeometric Operators to Assist the Detection of Keratoconus

    Directory of Open Access Journals (Sweden)

    Laurent Bataille

    2017-12-01

    Full Text Available The aim of this study is to describe a new keratoconus detection method based on the analysis of certain parametric morphogeometric operators extracted from a custom patient-specific three-dimensional (3D model of the human cornea. A corneal geometric reconstruction is firstly performed using zonal functions and retrospective Scheimpflug tomography data from 107 eyes of 107 patients. The posterior corneal surface is later analysed using an optimised computational geometry technique and the morphology of healthy and keratoconic corneas is characterized by means of geometric variables. The performance of these variables as predictors of a new geometric marker is assessed through a receiver operating characteristic (ROC curve analysis and their correlations are analysed through Pearson or Spearman coefficients. The posterior apex deviation variable shows the best keratoconus diagnosis capability. However, the strongest correlations in both healthy and pathological corneas are provided by the metrics directly related to the thickness as the sagittal plane area at the apex and the sagittal plane area at the minimum thickness point. A comparison of the screening of keratoconus provided by the Sirius topographer and the detection of corneal ectasia using the posterior apex deviation parameter is also performed, demonstrating the accuracy of this characterization as an effective marker of the diagnosis and ectatic disease progression.

  19. Detection of memory impairment in a community-based system: a collaborative study.

    Science.gov (United States)

    Kiral, Kahraman; Ozge, Aynur; Sungur, Mehmet Ali; Tasdelen, Bahar

    2013-05-01

    The ability to distinguish between older people with cognitive impairment and those who age in a healthy manner is crucial because cognitive impairment may be a precursor to full-blown dementia. Therefore, an early diagnosis of cognitive impairment is important. However, patients are often admitted to a hospital only when they already have a serious cognitive impairment. Consequently, cooperative studies between clinics and community-based organizations may assist hospitals in detecting early cognitive impairment. This article examines how community-based organizations can contribute to the early diagnosis of dementia. A cooperation model between the Neurology Department of Mersin University Hospital and the Mersin branch of the Alzheimer's Association was developed. Trained professionals used a neuropsychological battery to evaluate 50 individuals at the Mersin branch of the Alzheimer's Association in Turkey. Individuals whose performance fell below the average (1 standard deviation or less) were subsequently referred to the hospital. On the basis of the neurological and neuropsychological assessments, 11 participants were placed in the mild cognitive impairment group and 39 were placed in the healthy group. The results suggest that the Standardized Mini-Mental State Examination and the Three Words-Three Shapes Test are useful tools for detecting early memory impairments in a community-based setting.

  20. Performance of an artificial neural network for vertical root fracture detection: an ex vivo study.

    Science.gov (United States)

    Kositbowornchai, Suwadee; Plermkamon, Supattra; Tangkosol, Tawan

    2013-04-01

    To develop an artificial neural network for vertical root fracture detection. A probabilistic neural network design was used to clarify whether a tooth root was sound or had a vertical root fracture. Two hundred images (50 sound and 150 vertical root fractures) derived from digital radiography--used to train and test the artificial neural network--were divided into three groups according to the number of training and test data sets: 80/120,105/95 and 130/70, respectively. Either training or tested data were evaluated using grey-scale data per line passing through the root. These data were normalized to reduce the grey-scale variance and fed as input data of the neural network. The variance of function in recognition data was calculated between 0 and 1 to select the best performance of neural network. The performance of the neural network was evaluated using a diagnostic test. After testing data under several variances of function, we found the highest sensitivity (98%), specificity (90.5%) and accuracy (95.7%) occurred in Group three, for which the variance of function in recognition data was between 0.025 and 0.005. The neural network designed in this study has sufficient sensitivity, specificity and accuracy to be a model for vertical root fracture detection. © 2012 John Wiley & Sons A/S.

  1. Detection of residual packets in cocaine body packers: low accuracy of abdominal radiography - a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Rousset, Pascal; Vadrot, Dominique; Revel, Marie-Pierre [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Radiology, Paris (France); Universite Paris-Descartes, Paris (France); Chaillot, Pierre-Fleury [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Radiology, Paris (France); Audureau, Etienne [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Biostatistics and Epidemiology, Paris (France); Universite Paris-Descartes, Paris (France); Rey-Salmon, Caroline; Becour, Bertrand [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Forensic, Paris (France); Fitton, Isabelle [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Europeen Georges Pompidou, Department of Radiology, Paris (France)

    2013-08-15

    To evaluate the accuracy of abdominal radiography (AXR) for the detection of residual cocaine packets by comparison with computed tomography (CT). Over a 1-year period unenhanced CT was systematically performed in addition to AXR for pre-discharge evaluation of cocaine body packers. AXR and CT were interpreted independently by two radiologists blinded to clinical outcome. Patient and packet characteristics were compared between the groups with residual portage and complete decontamination. Among 138 body packers studied, 14 (10 %) had one residual packet identified on pre-discharge CT. On AXR, at least one reader failed to detect the residual packet in 10 (70 %) of these 14 body packers. The sensitivity and specificity of AXR were 28.6 % (95 % CI: 8.4-58.1) and 100.0 % (95 % CI: 97.0-100.0) for reader 1 and 35.7 % (95 % CI: 12.8-64.9) and 97.6 % (95 % CI: 93.1-99.5) for reader 2. There were no significant patient or packet characteristics predictive of residual portage or AXR false negativity. All positive CT results were confirmed by delayed expulsion or surgical findings, while negative results were confirmed by further surveillance. Given the poor performance of AXR, CT should be systematically performed to ensure safe hospital discharge of cocaine body packers. (orig.)

  2. Detection of residual packets in cocaine body packers: low accuracy of abdominal radiography - a prospective study

    International Nuclear Information System (INIS)

    Rousset, Pascal; Vadrot, Dominique; Revel, Marie-Pierre; Chaillot, Pierre-Fleury; Audureau, Etienne; Rey-Salmon, Caroline; Becour, Bertrand; Fitton, Isabelle

    2013-01-01

    To evaluate the accuracy of abdominal radiography (AXR) for the detection of residual cocaine packets by comparison with computed tomography (CT). Over a 1-year period unenhanced CT was systematically performed in addition to AXR for pre-discharge evaluation of cocaine body packers. AXR and CT were interpreted independently by two radiologists blinded to clinical outcome. Patient and packet characteristics were compared between the groups with residual portage and complete decontamination. Among 138 body packers studied, 14 (10 %) had one residual packet identified on pre-discharge CT. On AXR, at least one reader failed to detect the residual packet in 10 (70 %) of these 14 body packers. The sensitivity and specificity of AXR were 28.6 % (95 % CI: 8.4-58.1) and 100.0 % (95 % CI: 97.0-100.0) for reader 1 and 35.7 % (95 % CI: 12.8-64.9) and 97.6 % (95 % CI: 93.1-99.5) for reader 2. There were no significant patient or packet characteristics predictive of residual portage or AXR false negativity. All positive CT results were confirmed by delayed expulsion or surgical findings, while negative results were confirmed by further surveillance. Given the poor performance of AXR, CT should be systematically performed to ensure safe hospital discharge of cocaine body packers. (orig.)

  3. Nuclear medicine studies for the detection and metabolism of fibrinopeptide A

    International Nuclear Information System (INIS)

    Stehle, G.

    1982-01-01

    A modified method of the double antibody radioimmunoassay for the detection of Fibrinopeptide A (FPA) is presented. The change is primarily a shortening in time needed for this method from 15 to 4 hours by means of the substitution of the second antibody donkey for the second antibody goat with a simultaneous improvement of the specificity and an optimization of the conformity of the measured FPA concentrations. The second part of this work reports on the behaviour of FPA in vitro and in vivo in rabbits. The in vitro studies with 125I-FPA showed that there is no definite affinity of the peptide for blood components, that as a result of losses during the preparation the immunoreactivity of only 60% of the FPA can be determined with the IRA, and that 125I-FPA only loosely accumulates on proteins. The effective half-lives in blood of 25'' (α), 7' (β), 30' (γ) and 180' (δ) were determined. Weak metabolic reactions result in the indicator substance being stably present in the circ evenuation after 60', but it is quickly eliminated from the blood. An activity maximum was detected through scintigraphy shortly after the tracer dose in the heart, liver and kidneys, but after that it dropped exponentially and there was an increased concentration in the bladder after glomerular siltration in the kidneys. As a result of enzymatic processes in the tubulus of the kidney there is a higher portion of fragmented peptide in the urin than simultaneously in the plasma. (TRV) [de

  4. Rapid detection of bacteria in drinking water and water contamination case studies

    Science.gov (United States)

    Deininger, Rolf A.; Lee, Jiyoung; Clark, Robert M.

    2011-12-01

    Water systems are inherently vulnerable to physical, chemical and biologic threats that might compromise a systems' ability to reliably deliver safe water. The ability of a water supply to provide water to its customers can be compromised by destroying or disrupting key physical elements of the water system. However, contamination is generally viewed as the most serious potential terrorist threat to water systems. Chemical or biologic agents could spread throughout a distribution system and result in sickness or death among the consumers and for some agents the presence of the contaminant might not be known until emergency rooms report an increase in patients with a particular set of symptoms. Even without serious health impacts, just the knowledge that a water system had been breached could seriously undermine consumer confidence in public water supplies. Therefore, the ability to rapidly detect contamination, especially microbiological contamination, is highly desirable. The authors summarize water contamination case studies and discuss a technique for identifying microbiological contamination based on ATP bioluminescence. This assay allows an estimation of bacterial populations within minutes and can be applied using a local platform. Previous ATP-based methods requires one hour, one liter of water, and has a sensitivity of 100000 cells for detection. The improved method discussed here is 100 times more sensitive, requires one-hundredth of the sample volume, and is over 10 times faster than standard method. This technique has a great deal of potential for application in situations in which a water system has been compromised.

  5. Preliminary study on detection technology of the cladding weld of spent fuel storage pool

    Science.gov (United States)

    Qi, Pan; Cui, Hongyan; Feng, Meiming; Shao, Wenbin; Liao, Shusheng; Li, Wei

    2018-04-01

    As the first barrier of the Spent fuel storage pool, the steel cladding using different sizes (length×width) of 304L stainless steel with 3˜6mm thickness plate argon arc welded together which is direct contacted with boric acid water. Environmental humidity between the back of steel cladding and concrete, makes phosphate, chloride ion overflowed from the concrete that corroded on the weld zone with different mechanism. Part of the corrosion defects can penetrate leaded to leakage of boric acid water in penetration position accelerated crack propagation. In view of the above situation and combined with the actual needs of the power plant, the development of effective underwater nondestructive testing means of the weld area for periodic inspection and monitoring is necessary. A single method may lead to the missing of defects detection due to weld reinforcement unpolished. In this paper, eddy current array (ARRAY) and Alternating Current Field Measurement (ACFM) are adapted to test the limit sensitivity and resolution through by the specimens with artificial defects which make their detection abilities close to satisfy engineering requirements. The preliminary study found that Φ0.5mm through-wall hole and with 2mm length and 0.3mm width through-wall crack in the weld can be good inspected.

  6. Suma-alpha software description. Study of its applications to detection problems and environmental radioactivity measurements

    International Nuclear Information System (INIS)

    Gasco, C.; Perez, C.

    2010-01-01

    Software named suma-espectros has been developed by TECNASA/CIEMAT for adding counts automatically from the alpha spectra, energy to energy, with the purpose of: evaluating real background of alpha spectrometers, studying its temporal variations, increasing the possibilities of isotopes detection -where it has been impossible to detect due elapsed time of the measurement- and implementing other applications. The programme is written in Visual-Basic and it can export data to Excel spreadsheets for later treatment. The software has established by default a channels range for adding the counts energy by energy but it can be adapted to the analysis of different isotopes and backgrounds simply changing a text file that is incorporated to the programme. The description of the programme management is described for whoever can realise its applications immediately. This software has the advantage of emitting an add-spectrum in cnf format that is used by alpha analyst (Genie 2K) for de convoluting spectra or doing calculations. (Author) 3 refs.

  7. Early detection of COPD: a case finding study in general practice.

    Science.gov (United States)

    Vandevoorde, Jan; Verbanck, Sylvia; Gijssels, Lieve; Schuermans, Daniel; Devroey, Dirk; De Backer, Joan; Kartounian, Jan; Vincken, Walter

    2007-03-01

    To estimate the prevalence of undiagnosed chronic obstructive pulmonary disease (COPD) in a population of general practice patients at risk for developing COPD. A further aim was to evaluate the presence of respiratory symptoms as a predictor for the diagnosis of COPD. This study was conducted by eight general practitioners (GP) in six semi-rural general practices. During two consecutive months all patients attending their GP were included if they met the following criteria: current smokers between 40 and 70 yr of age, and a smoking history of at least 15 pack-years. A questionnaire regarding smoking history, respiratory symptoms, exposure to dust or chemical fumes, and history of respiratory diseases was completed for all patients. Subjects without known COPD were invited for spirometric testing. Off the 146 general practice patients included, 17.1% already had an established COPD diagnosis. Screening by spirometry revealed a 46.6% prevalence of COPD. Underdiagnosis of COPD was more frequent in the younger age categories (40-49 Yr; 50-59 Yr). Objective wheezing was the only sign that was significantly more frequent in COPD patients than in non-COPD patients (Pfatigue than newly detected patients. Almost half of a general practice population of current smokers between 40 and 70 years of age, with a smoking history of at least 15 pack-years, was diagnosed with COPD, and roughly two thirds of these were newly detected as a result of the case finding programme.

  8. Irish study of high-density Schizophrenia families: Field methods and power to detect linkage

    Energy Technology Data Exchange (ETDEWEB)

    Kendler, K.S.; Straub, R.E.; MacLean, C.J. [Virginia Commonwealth Univ., Richmond, VA (United States)] [and others

    1996-04-09

    Large samples of multiplex pedigrees will probably be needed to detect susceptibility loci for schizophrenia by linkage analysis. Standardized ascertainment of such pedigrees from culturally and ethnically homogeneous populations may improve the probability of detection and replication of linkage. The Irish Study of High-Density Schizophrenia Families (ISHDSF) was formed from standardized ascertainment of multiplex schizophrenia families in 39 psychiatric facilities covering over 90% of the population in Ireland and Northern Ireland. We here describe a phenotypic sample and a subset thereof, the linkage sample. Individuals were included in the phenotypic sample if adequate diagnostic information, based on personal interview and/or hospital record, was available. Only individuals with available DNA were included in the linkage sample. Inclusion of a pedigree into the phenotypic sample required at least two first, second, or third degree relatives with non-affective psychosis (NAP), one of whom had schizophrenia (S) or poor-outcome schizoaffective disorder (PO-SAD). Entry into the linkage sample required DNA samples on at least two individuals with NAP, of whom at least one had S or PO-SAD. Affection was defined by narrow, intermediate, and broad criteria. 75 refs., 6 tabs.

  9. Expert opinion on detecting and treating depression in palliative care: A Delphi study

    Directory of Open Access Journals (Sweden)

    Hotopf Matthew

    2011-05-01

    Full Text Available Abstract Background There is a dearth of data regarding the optimal method of detecting and treating depression in palliative care. This study applied the Delphi method to evaluate expert opinion on choice of screening tool, choice of antidepressant and choice of psychological therapy. The aim was to inform the development of best practice recommendations for the European Palliative Care Research Collaborative clinical practice guideline on managing depression in palliative care. Methods 18 members of an international, multi-professional expert group completed a structured questionnaire in two rounds, rating their agreement with proposed items on a scale from 0-10 and annotating with additional comments. The median and range were calculated to give a statistical average of the experts' ratings. Results There was contention regarding the benefits of screening, with 'routine informal asking' (median 8.5 (0-10 rated more highly than formal screening tools such as the Hospital Anxiety and Depression Scale (median 7.0 (1-10. Mirtazapine (median 9 (7-10 and citalopram (median 9 (5-10 were the considered the best choice of antidepressant and cognitive behavioural therapy (median 9.0 (3-10 the best choice of psychological therapy. Conclusions The range of expert ratings was broad, indicating discordance in the views of experts. Direct comparative data from randomised controlled trials are needed to strengthen the evidence-base and achieve clarity on how best to detect and treat depression in this setting.

  10. A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria.

    Science.gov (United States)

    Parija, S C; Dhodapkar, Rahul; Elangovan, Subashini; Chaya, D R

    2009-01-01

    Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC), plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman's stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman's thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.

  11. A comparative study of blood smear, QBC and antigen detection for diagnosis of malaria

    Directory of Open Access Journals (Sweden)

    Parija S

    2009-04-01

    Full Text Available Rapid diagnosis is prerequisite for effective treatment and reducing mortality and morbidity of malaria. This study was taken up to compare the efficacy of various methods available, i.e., thick and thin smear, quantitative buffy coat (QBC, plasmodium lactate dehydrogenase and aldolase in blood of patient. A total of 411 samples were collected from patients presenting with classic symptoms of malaria. For traditional microscopy; thick and thin smears were prepared and stained with Leishman′s stain, taking thick smear as gold standard, thin smear had a sensitivity and specificity of 54.8% and 100%, respectively. QBC and antigen detection was done using commercially available kits; out of 411 samples, QBC and Malariagen were positive in 66 and 62 cases, with a sensitivity of 78% and 75%, respectively. Leishman′s thick smear, although cost effective, is difficult to interpret for inexperienced microscopists; so if facilities are available, QBC should be used for routine diagnosis. In places where facilities are not available, rapid, simple and easy to interpret antigen detection test can be used despite low sensitivity.

  12. Urine colorimetry to detect Low rifampin exposure during tuberculosis therapy: a proof-of-concept study.

    Science.gov (United States)

    Zentner, Isaac; Schlecht, Hans P; Khensouvann, Lorna; Tamuhla, Neo; Kutzler, Michele; Ivaturi, Vijay; Pasipanodya, Jotam G; Gumbo, Tawanda; Peloquin, Charles A; Bisson, Gregory P; Vinnard, Christopher

    2016-06-01

    The cost and complexity of current approaches to therapeutic drug monitoring during tuberculosis (TB) therapy limits widespread use in areas of greatest need. We sought to determine whether urine colorimetry could have a novel application as a form of therapeutic drug monitoring during anti-TB therapy. Among healthy volunteers, we evaluated 3 dose sizes of rifampin (150 mg, 300 mg, and 600 mg), performed intensive pharmacokinetic sampling, and collected a timed urine void at 4 h post-dosing. The absorbance peak at 475 nm was measured after rifamycin extraction. The optimal cutoff was evaluated in a study of 39 HIV/TB patients undergoing TB treatment in Botswana. In the derivation study, a urine colorimetric assay value of 4.0 × 10(-2) Abs, using a timed void 4 h after dosing, demonstrated a sensitivity of 92 % and specificity of 60 % to detect a peak rifampin concentration (Cmax) under 8 mg/L, with an area under the ROC curve of 0.92. In the validation study, this cutoff was specific (100 %) but insensitive (28 %). We observed similar test characteristics for a target Cmax target of 6.6 mg/L, and a target area under the drug concentration-versus-time curve (AUC0-8) target of 24.1 mg•hour/L. The urine colorimetric assay was specific but insensitive to detect low rifampin serum concentrations among HIV/TB patients. In future work we will attempt to optimize sampling times and assay performance, with the goal of delivering a method that can translate into a point-of-care assessment of rifampin exposure during anti-TB therapy.

  13. Detection of lung cancer on the chest radiograph: a study on observer performance

    International Nuclear Information System (INIS)

    Quekel, Lorentz G.B.A.; Kessels, Alphons G.H.; Goei, Reginald; Engelshoven, Joseph M.A. van

    2001-01-01

    Study objectives: to study the validity and observers consistency in the detection of lung cancer on the chest radiograph. Materials and methods: the chest radiographs of 100 clinical cases were interpreted by 14 observers. The radiographs were obtained from 30 patients with initially missed but histopathologically proven non-small cell lung cancer (NSCLC), 35 patients with other cardiopulmonary diseases and 35 patients with no abnormalities. The observers consisted of ten experienced radiologists, two-experienced chest physicians and two residents in radiology. All observers were unaware of the study design. The validity and observer consistency was determined for each observer. Results: the mean sensitivity and specificity of the ten radiologists were 0.36 and 0.90. For the two chest physicians, the mean sensitivity and specificity were 0.29 and 0.96. For the two residents in radiology, mean sensitivity and specificity were 0.25 and 0.94. The mean interobserver kappa and mean intraobserver kappa for the radiologists were 0.38 and 0.54. For the two chest physicians, the mean interobserver kappa was 0.43, while the intraobserver kappa was 0.59. For the two residents in radiology, mean interobserver kappa was 0.35 and the intraobserver kappa was 0.42. There was no significant relation between the consistency parameters and validity parameters. The interobserver and intraobserver kappa values showed good correlation. Conclusion: the validity of the chest radiograph and observers consistency in the detection of nodular lung cancer varies widely. The level of experience is likely to influence the diagnostic performance

  14. Real time hybridization studies by resonant waveguide gratings using nanopattern imaging for Single Nucleotide Polymorphism detection

    KAUST Repository

    Bougot-Robin, Kristelle

    2013-12-20

    2D imaging of biochips is particularly interesting for multiplex biosensing. Resonant properties allow label-free detection using the change of refractive index at the chip surface. We demonstrate a new principle of Scanning Of Resonance on Chip by Imaging (SORCI) based on spatial profiles of nanopatterns of resonant waveguide gratings (RWGs) and its embodiment in a fluidic chip for real-time biological studies. This scheme allows multiplexing of the resonance itself by providing nanopattern sensing areas in a bioarray format. Through several chip designs we discuss resonance spatial profiles, dispersion and electric field distribution for optimal light-matter interaction with biological species of different sizes. Fluidic integration is carried out with a black anodized aluminum chamber, advantageous in term of mechanical stability, multiple uses of the chip, temperature control and low optical background. Real-time hybridization experiments are illustrated by SNP (Single Nucleotide Polymorphism) detection in gyrase A of E. coli K12, observed in evolution studies of resistance to the antibiotic ciprofloxacin. We choose a 100 base pairs (bp) DNA target (∼30 kDa) including the codon of interest and demonstrate the high specificity of our technique for probes and targets with close affinity constants. This work validates the safe applicability of our unique combination of RWGs and simple instrumentation for real-time biosensing with sensitivity in buffer solution of ∼10 pg/mm2. Paralleling the success of RWGs sensing for cells sensing, our work opens new avenues for a large number of biological studies. © 2013 Springer Science+Business Media.

  15. Optimal search strategies for detecting cost and economic studies in EMBASE

    Directory of Open Access Journals (Sweden)

    Haynes R Brian

    2006-06-01

    Full Text Available Abstract Background Economic evaluations in the medical literature compare competing diagnosis or treatment methods for their use of resources and their expected outcomes. The best evidence currently available from research regarding both cost and economic comparisons will continue to expand as this type of information becomes more important in today's clinical practice. Researchers and clinicians need quick, reliable ways to access this information. A key source of this type of information is large bibliographic databases such as EMBASE. The objective of this study was to develop search strategies that optimize the retrieval of health costs and economics studies from EMBASE. Methods We conducted an analytic survey, comparing hand searches of journals with retrievals from EMBASE for candidate search terms and combinations. 6 research assistants read all issues of 55 journals indexed by EMBASE for the publishing year 2000. We rated all articles using purpose and quality indicators and categorized them into clinically relevant original studies, review articles, general papers, or case reports. The original and review articles were then categorized for purpose (i.e., cost and economics and other clinical topics and depending on the purpose as 'pass' or 'fail' for methodologic rigor. Candidate search strategies were developed for economic and cost studies, then run in the 55 EMBASE journals, the retrievals being compared with the hand search data. The sensitivity, specificity, precision, and accuracy of the search strategies were calculated. Results Combinations of search terms for detecting both cost and economic studies attained levels of 100% sensitivity with specificity levels of 92.9% and 92.3% respectively. When maximizing for both sensitivity and specificity, the combination of terms for detecting cost studies (sensitivity increased 2.2% over the single term but at a slight decrease in specificity of 0.9%. The maximized combination of terms

  16. Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Shane M. Summers, MD, RDMS

    2016-03-01

    Full Text Available Introduction: Bedside thoracic ultrasound (US can rapidly diagnose pneumothorax (PTX with improved accuracy over the physical examination and without the need for chest radiography (CXR; however, US is highly operator dependent. A computerized diagnostic assistant was developed by the United States Army Institute of Surgical Research to detect PTX on standard thoracic US images. This computer algorithm is designed to automatically detect sonographic signs of PTX by systematically analyzing B-mode US video clips for pleural sliding and M-mode still images for the seashore sign. This was a pilot study to estimate the diagnostic accuracy of the PTX detection computer algorithm when compared to an expert panel of US trained physicians. Methods: This was a retrospective study using archived thoracic US obtained on adult patients presenting to the emergency department (ED between 5/23/2011 and 8/6/2014. Emergency medicine residents, fellows, attending physicians, physician assistants, and medical students performed the US examinations and stored the images in the picture archive and communications system (PACS. The PACS was queried for all ED bedside US examinations with reported positive PTX during the study period along with a random sample of negatives. The computer algorithm then interpreted the images, and we compared the results to an independent, blinded expert panel of three physicians, each with experience reviewing over 10,000 US examinations. Results: Query of the PACS system revealed 146 bedside thoracic US examinations for analysis. Thirteen examinations were indeterminate and were excluded. There were 79 true negatives, 33 true positives, 9 false negatives, and 12 false positives. The test characteristics of the algorithm when compared to the expert panel were sensitivity 79% (95 % CI [63-89] and specificity 87% (95% CI [77-93]. For the 20 images scored as highest quality by the expert panel, the algorithm demonstrated 100% sensitivity

  17. Marine migrations in anadromous brown trout (Salmo trutta). Fjord residency as a possible alternative in the continuum of migration to the open sea

    DEFF Research Database (Denmark)

    Del Villar, Diego; Aarestrup, Kim; Skov, Christian

    2014-01-01

    with acoustic and PIT-tags in the river Villestrup (Denmark) to study the initial postsmolt marine behaviour within a fjord system. We found that the strategies of the sea migrants vary: some stay in the fjord, while others migrate to the sea, suggesting that partial migration occurs even in the marine...

  18. Evaluation of Dual Frequency Identification Sonar (DIDSON) for Monitoring Pacific Lamprey Passage Behavior at Fishways of Bonneville Dam, 2011

    Science.gov (United States)

    2012-01-01

    Mundy’s Welding and the University of Idaho machine shop who went out of their way to manufacture and modify our sampling gear. We also thank R. Poulin, C...Columbia River: 2008 radiotelemetry and half- duplex PIT tag studies. Technical Report 2009-8 of Idaho Cooperative Fish and Wildlife Research Unit to U.S

  19. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet.

    Science.gov (United States)

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.

  20. Comparative Study of Outlier Detection Algorithms via Fundamental Analysis Variables: An Application on Firms Listed in Borsa Istanbul

    Directory of Open Access Journals (Sweden)

    Senol Emir

    2016-04-01

    Full Text Available In a data set, an outlier refers to a data point that is considerably different from the others. Detecting outliers provides useful application-specific insights and leads to choosing right prediction models. Outlier detection (also known as anomaly detection or novelty detection has been studied in statistics and machine learning for a long time. It is an essential preprocessing step of data mining process. In this study, outlier detection step in the data mining process is applied for identifying the top 20 outlier firms. Three outlier detection algorithms are utilized using fundamental analysis variables of firms listed in Borsa Istanbul for the 2011-2014 period. The results of each algorithm are presented and compared. Findings show that 15 different firms are identified by three different outlier detection methods. KCHOL and SAHOL have the greatest number of appearances with 12 observations among these firms. By investigating the results, it is concluded that each of three algorithms makes different outlier firm lists due to differences in their approaches for outlier detection.

  1. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    Directory of Open Access Journals (Sweden)

    Reiko Sawada

    2017-06-01

    Full Text Available Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food, low-fat food (i.e., Japanese diet, and non-food (i.e., kitchen utensils targets within crowds of non-food distractors (i.e., cars. Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.

  2. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    Science.gov (United States)

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection. PMID:28690568

  3. [A review on studies and applications of near infrared spectroscopy technique(NIRS) in detecting quality of hay].

    Science.gov (United States)

    Ding, Wu-Rong; Gan, You-Min; Guo, Xu-Sheng; Yang, Fu-Yu

    2009-02-01

    The quality of hay can directly affect the price of hay and also livestock productivity. Many kinds of methods have been developed for detecting the quality of hay and the method of near infrared spectroscopy (NIRS) has been widely used with consideration of its fast, effective and nondestructive characteristics during detecting process. In the present paper, the feasibility and effectiveness of application of NIRS to detecting hay quality were expounded. Meanwhile, the advance in the study of using NIRS to detect chemical compositions, extent of incursion by epiphyte, amount of toxicant excreted by endogenetic epiphyte and some minim components that can not be detected by using chemical methods were also introduced detailedly. Based on the review of the progresses in using NIRS to detect the quality of hay, it can be concluded that using NIRS to detect hay quality can avoid the disadvantages of time wasting, complication and high cost when using traditional chemical method. And for better utilization of NIRS in practice, some more studies still need to be implemented to further perfect and improve the utilization of NIRS for detecting forage quality, and more accurate modes and systematic analysis software need to be established in times to come.

  4. Studies on the detection of erythrocytic antibodies with a radioimmuno-antiglobulin assay

    International Nuclear Information System (INIS)

    Djibey, I.M.

    1979-01-01

    The RIA with I-125-anti-IgG and I-125-anti-C3b was used. Various factors in RIA were tested for the purpose of optimisation. As a rule, incomplete anti-D (test serum of one charge) was used. Anti-Kell was used for specific problems. After optimisation of the method, patient sera were studied which contained auto- or allo-antibodies in the fresh state. More significant findings were obtained with the direct RIAGT. Indirect methods did not show a clearly enhanced detection sensitivity of erythrocyte autoantibodies, but they may serve for a closer investigation of diffuse reactions of patient sera in the enzyme test. The direct RIA is clearly of advantage in cases in which the complement Coombs test alone is positive. (orig./MG) [de

  5. Gold-silica nanocomposites for the detection of human ovarian cancer cells: a preliminary study

    International Nuclear Information System (INIS)

    Mishra, Y K; Mohapatra, S; Avasthi, D K; Kabiraj, D; Lalla, N P; Pivin, J C; Sharma, Himani; Kar, Rajarshi; Singh, Neeta

    2007-01-01

    We report the structural and optical properties of Au nanoparticles embedded in a silica matrix synthesized by atom beam co-sputtering. The presence of surface plasmon resonant absorption indicates the formation of Au nanoparticles. Transmission electron microscopy (TEM) studies show the presence of Au nanoparticles with an average size ranging from ∼1.8 to 5.4 nm with narrow size distributions depending on the relative areas of Au and SiO 2 . We discuss the process of nucleation and growth of Au nanoparticles in the nanocomposite films formed by co-sputtering. The present method of nanoparticle synthesis is compared with other ion beam based techniques such as ion implantation and ion beam mixing. Preliminary experiments for the detection of human ovarian cancer cells using these Au nanoparticles are described

  6. Study and characterization of III-V semiconductor materials for applications in ionizing radiation detection

    International Nuclear Information System (INIS)

    Moulin, H.

    1989-11-01

    The photoconduction in the bulk of the gallium arsenide (GaAs) and of the indium phosphide doped with iron (InP:Fe) is investigated. These semiconductor materials are to be applied in X rays detection. The photoconduction theory and the physical characteristics of those materials are reviewed. The computer simulation models for studying the photoconductor responses to the radiation pulses are described. The experimental results are discussed. They include the following aspects: the characterization of the GaAs and InP:Fe, in the obscurity, as a function of the polarized electric field and of the neutrons dose; the characterization under X ray. Continuous X rays and pulsed synchrotron radiation are applied [fr

  7. Study on detecting leachate leakage of municipal solid waste landfill site.

    Science.gov (United States)

    Liu, Jiangang; Cao, Xianxian; Ai, Yingbo; Zhou, Dongdong; Han, Qiting

    2015-06-01

    The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7. © The Author(s) 2015.

  8. A study to detect factors influencing the formation of loyal customers’ mental image

    Directory of Open Access Journals (Sweden)

    Erfan Sobhaninia

    2014-01-01

    Full Text Available Understanding customers’ behavior normally helps planning better marketing strategies, which could lead to an increase in market share and profitability. Loyal customers are always considered as the most important assets for any firm. This paper presents a survey to detect factors influencing the formation of loyal customers’ mental image. The proposed study uses factor analysis to determine these factors by designing a questionnaire and distributing among some loyal customers who do banking business in Bank Melli Iran located in city of Tehran, Iran. The results indicate that there were eight important factors influencing customer loyalty including social status, business identity, brand strength, the contract role, organizational benefit, consumer rights, organizational image and supporting power.

  9. Study of thermoluminescence emissions of dosimetric phosphors; the detection of intermediate neutrons

    International Nuclear Information System (INIS)

    Santos, E.N. dos.

    1979-01-01

    Thermally stimulated luminescence (TSL) studies have been carried out in cold-pressed CaSO 4 +DY 2 O 3 +KCl (specimen 1) and natural CaF 2 +DY 2 O 3 + KCl (specimen 2) polycrystaline samples. The ratios of the TSL sensivities of specimens 1 and 2 relative to that of 6 LiF:Mg;Ti (TLD-600) are found to be 24 and 3, respectively. The minimum detectable neutron fluence has been determined to be approximately 3.5X10 5 n/cm 2 . The determination of the effective half-life of the TSL emission lead to the identification of the isotope responsible for the self-irradiation of the specimens: 165 66 DY. (F.E.) [pt

  10. Study and realization of a detection apparatus for the Grenoble magnetic spectrometer

    International Nuclear Information System (INIS)

    Burel, J.-P.

    1975-01-01

    Two multiwire proportional chambers were studied for a magnetic spectrometer. The first one is constructed for visualization of the attenuated beam at the place of the target. The sensitive area is 4x4cm 2 . The anode wires are 0.020mm diameter, gold plated tungsten, 2mm spaced. Each cathode plane wires are connected to a 20 units-5ns delay line. The planes are 3.2mm spaced. The spatial resolution obtained is better than 0.3mm. The second chamber is placed at the focal plane of the spectrometer. The sensitive area is 50x5cm 2 . The horizontal position detection uses an original charge-division system with four chains of capacitors. The particle position results of the center of gravity calculus of different amplified pulses. An electronic circuit has been constructed and the result is directly stored in a memory unit. The spatial resolution obtained is 0.4mm [fr

  11. P-N defect in GaNP studied by optically detected magnetic resonance

    International Nuclear Information System (INIS)

    Chen, W.M.; Thinh, N.Q.; Vorona, I.P.; Buyanova, I.A.; Xin, H.P.; Tu, C.W.

    2003-01-01

    We provide experimental evidence for an intrinsic defect in GaNP from optically detected magnetic resonance (ODMR). This defect is identified as a P-N complex, exhibiting hyperfine structure due to interactions with a nuclear spin I=((1)/(2)) of one P atom and also a nuclear spin I=1 due to one N atom. The introduction of the defect is assisted by the incorporation of N within the studied N composition range of up to 3.1%, under non-equilibrium growth conditions during gas-source molecular beam epitaxy. The corresponding ODMR spectrum was found to be isotropic, suggesting an A 1 symmetry of the defect state. The localization of the electron wave function at the P-N defect in GaNP is found to be even stronger than that for the isolated P Ga antisite in its parent binary compound GaP

  12. Detection and identification of nitrogen defects in nanodiamond as studied by EPR

    Energy Technology Data Exchange (ETDEWEB)

    Soltamova, A.A.; Ilyin, I.V. [Ioffe Physical Technical Institute, Politechnicheskaya, 26, St. Petersburg 194021 (Russian Federation); Baranov, P.G., E-mail: pavel.baranov@mail.ioffe.r [Ioffe Physical Technical Institute, Politechnicheskaya, 26, St. Petersburg 194021 (Russian Federation); Vul' , A.Ya.; Kidalov, S.V.; Shakhov, F.M. [Ioffe Physical Technical Institute, Politechnicheskaya, 26, St. Petersburg 194021 (Russian Federation); Mamin, G.V.; Orlinskii, S.B.; Silkin, N.I.; Salakhov, M.Kh. [Kazan State University, Federal Center of Shared Usage for Physicochemical Measurements, Kazan 420008 (Russian Federation)

    2009-12-15

    Electron paramagnetic resonance (EPR) and electron spin echo (ESE) at X-band and at high-frequency W-band (95 GHz) have been used to study defects in natural diamond nanocrystals, detonation nanodiamond (ND) with a size of approx4.5 nm and detonation ND after high-temperature, high-pressure sintering with a size of approx8.5 nm. Atomic nitrogen centers N{sup 0} and nitrogen pairs N{sub 2}{sup +} have been detected and identified and their structure has been unambiguously determined by means of the high frequency EPR and ESE in natural diamond nanocrystals. In detonation ND and detonation ND after sintering atomic nitrogen centers N{sup 0} have been discovered in nanodiamond core. In addition EPR signal of multi-vacancy centers with spin 3/2 seems to be observed in diamond core of detonation ND.

  13. The Impact of an ECV Service is Limited by Antenatal Breech Detection: A Retrospective Cohort Study.

    Science.gov (United States)

    Hemelaar, Joris; Lim, Lee N; Impey, Lawrence W

    2015-06-01

    External cephalic version (ECV) reduces the chance of breech presentation at term birth and lowers the chance of a cesarean delivery. ECV services are now in place in many units in the United Kingdom but their effectiveness is unknown. The aim of this study was to investigate the reasons for breech presentation at term birth. We performed a retrospective cohort study of 394 consecutive babies who were in breech presentation at term birth in a large United Kingdom maternity unit that offers ECV. The cohort was analyzed over two time periods 10 years apart: 1998-1999 and 2008-2009. Only 33.8 percent of women had undergone a (failed) ECV attempt. This low proportion was mainly because breech presentation was not diagnosed antenatally (27.9%). Other contributing factors were: ECV not offered by clinicians (12.2%), ECV declined by women (14%), and contraindications to ECV (10.7%). Over the 10-year period, the proportion of breech presentations that were not diagnosed antenatally increased from 23.2 to 32.5 percent (p = 0.04), which constituted 52.8 percent of women who had not undergone an ECV attempt in 2008-2009. Failure of clinicians to offer ECV reduced from 21.6 to 3.0 percent (p = 0.0001) and the proportion of women declining ECV decreased from 19.1 to 9.0 percent (p = 0.005). Overall, ECV attempts increased from 28.9 to 38.5 percent (p = 0.05). Although ECV counseling, referral, and attempt rates have increased, failure to detect breech presentation antenatally is the principal barrier to successful ECV. Improved breech detection would have a greater impact than methods to increase ECV success rates. © 2015 Wiley Periodicals, Inc.

  14. Studies of Ink Trapping III Direct Detection of Small Air Bubbles in Ink Layer

    Directory of Open Access Journals (Sweden)

    Ikuo Naito

    2006-12-01

    Full Text Available Ink trappings were studied by using polyethylene terephthalate (PET film with black inks for offset proofing and synthetic paper. By observing printed matter from reverse side through the PET film, we detected many air bubbles in the ink layer and between the ink layer and the PET film. They are classified roughly to two groups, small number of large ones (φ = 2 - 5 μm and many small ones (φ = 0.5 - 1.0 μm. The former ones were fixed air bubbles during the trapping. The latter ones decreased according to increase the amount of ink trapped (y. Because number of the air bubbles (Nair bubble increased with increasing the ink distribution time, they seemed to be yielded by suspension of air into the ink layer during ink distribution. By observing printed surface, we also detected many ink peaks (immediately after the trapping and pinholes (at 24 h. The numbers of the ink peaks and pinholes (Nink peak and Npinhole, respectively decreased also with increasing the y value and increased with increasing the ink distribution time. We studied effects of nip width on these values (distribution time = 2 min.; nip width = 2, 3 and 4 mm. The Nair bubble value decreased with increasing nip width contrary to increase the Nink peak and Npinhole values. The effects can be represented by differences in the values of 2 and 4 mm nip widths. At y = 2 gm-2, the difference in the Nair bubble value is about one third (synthetic paper ink or a half (offset proofing ink of the difference in the Nink peak values.

  15. SOPROCARE - 450 nm wavelength detection tool for microbial plaque and gingival inflammation: a clinical study

    Science.gov (United States)

    Rechmann, P.; Liou, Shasan W.; Rechmann, Beate M.; Featherstone, John D.

    2014-02-01

    Gingivitis due to microbial plaque and calculus can lead over time if left untreated to advanced periodontal disease with non-physiological pocket formation. Removal of microbial plaque in the gingivitis stage typically achieves gingival health. The SOPROCARE camera system emits blue light at 450 nm wavelength using three blue diodes. The 450 nm wavelength is located in the non-ionizing, visible spectral wavelength region and thus is not dangerous. It is assumed that using the SOPROCARE camera in perio-mode inflamed gingiva can easily be observed and inflammation can be scored due to fluorescence from porphyrins in blood. The assumption is also that illumination of microbial plaque with blue light induces fluorescence due to the bacteria and porphyrin content of the plaque and thus can help to make microbial plaque and calculus visible. Aim of the study with 55 subjects was to evaluate the ability of the SOPROCARE fluorescence camera system to detect, visualize and allow scoring of microbial plaque in comparison to the Turesky modification of the Quigley and Hein plaque index. A second goal was to detect and score gingival inflammation and correlated the findings to the Silness and Löe gingival inflammation index. The study showed that scoring of microbial plaque as well as gingival inflammation levels similar to the established Turesky modified Quigley Hein index and the Silness and Löe gingival inflammation index can easily be done using the SOPROCARE fluorescence system in periomode. Linear regression fits between the different clinical indices and SOPROCARE scores in fluorescence perio-mode revealed the system's capacity for effective discrimination between scores.

  16. Detection of microsleep events in a car driving simulation study using electrocardiographic features

    Directory of Open Access Journals (Sweden)

    Lenis Gustavo

    2016-09-01

    Full Text Available Microsleep events (MSE are short intrusions of sleep under the demand of sustained attention. They can impose a major threat to safety while driving a car and are considered one of the most significant causes of traffic accidents. Driver’s fatigue and MSE account for up to 20% of all car crashes in Europe and at least 100,000 accidents in the US every year. Unfortunately, there is not a standardized test developed to quantify the degree of vigilance of a driver. To account for this problem, different approaches based on biosignal analysis have been studied in the past. In this paper, we investigate an electrocardiographic-based detection of MSE using morphological and rhythmical features. 14 records from a car driving simulation study with a high incidence of MSE were analyzed and the behavior of the ECG features before and after an MSE in relation to reference baseline values (without drowsiness were investigated. The results show that MSE cannot be detected (or predicted using only the ECG. However, in the presence of MSE, the rhythmical and morphological features were observed to be significantly different than the ones calculated for the reference signal without sleepiness. In particular, when MSE were present, the heart rate diminished while the heart rate variability increased. Time distances between P wave and R peak, and R peak and T wave and their dispersion increased also. This demonstrates a noticeable change of the autonomous regulation of the heart. In future, the ECG parameter could be used as a surrogate measure of fatigue.

  17. Versatile single-molecule multi-color excitation and detection fluorescence setup for studying biomolecular dynamics

    KAUST Repository

    Sobhy, M. A.

    2011-11-07

    Single-molecule fluorescence imaging is at the forefront of tools applied to study biomolecular dynamics both in vitro and in vivo. The ability of the single-molecule fluorescence microscope to conduct simultaneous multi-color excitation and detection is a key experimental feature that is under continuous development. In this paper, we describe in detail the design and the construction of a sophisticated and versatile multi-color excitation and emission fluorescence instrument for studying biomolecular dynamics at the single-molecule level. The setup is novel, economical and compact, where two inverted microscopes share a laser combiner module with six individual laser sources that extend from 400 to 640 nm. Nonetheless, each microscope can independently and in a flexible manner select the combinations, sequences, and intensities of the excitation wavelengths. This high flexibility is achieved by the replacement of conventional mechanical shutters with acousto-optic tunable filter (AOTF). The use of AOTF provides major advancement by controlling the intensities, duration, and selection of up to eight different wavelengths with microsecond alternation time in a transparent and easy manner for the end user. To our knowledge this is the first time AOTF is applied to wide-field total internal reflection fluorescence (TIRF) microscopy even though it has been commonly used in multi-wavelength confocal microscopy. The laser outputs from the combiner module are coupled to the microscopes by two sets of four single-mode optic fibers in order to allow for the optimization of the TIRF angle for each wavelength independently. The emission is split into two or four spectral channels to allow for the simultaneous detection of up to four different fluorophores of wide selection and using many possible excitation and photoactivation schemes. We demonstrate the performance of this new setup by conducting two-color alternating excitation single-molecule fluorescence resonance energy

  18. Methods for the Detection, Study, and Dynamic Profiling of O-GlcNAc Glycosylation.

    Science.gov (United States)

    Thompson, John W; Griffin, Matthew E; Hsieh-Wilson, Linda C

    2018-01-01

    The addition of O-linked β-N-acetylglucosamine (O-GlcNAc) to serine/threonine residues of proteins is a ubiquitous posttranslational modification found in all multicellular organisms. Like phosphorylation, O-GlcNAc glycosylation (O-GlcNAcylation) is inducible and regulates a myriad of physiological and pathological processes. However, understanding the diverse functions of O-GlcNAcylation is often challenging due to the difficulty of detecting and quantifying the modification. Thus, robust methods to study O-GlcNAcylation are essential to elucidate its key roles in the regulation of individual proteins, complex cellular processes, and disease. In this chapter, we describe a set of chemoenzymatic labeling methods to (1) detect O-GlcNAcylation on proteins of interest, (2) monitor changes in both the total levels of O-GlcNAcylation and its stoichiometry on proteins of interest, and (3) enable mapping of O-GlcNAc to specific serine/threonine residues within proteins to facilitate functional studies. First, we outline a procedure for the expression and purification of a multiuse mutant galactosyltransferase enzyme (Y289L GalT). We then describe the use of Y289L GalT to modify O-GlcNAc residues with a functional handle, N-azidoacetylgalactosamine (GalNAz). Finally, we discuss several applications of the copper-catalyzed azide-alkyne cycloaddition "click" reaction to attach various alkyne-containing chemical probes to GalNAz and demonstrate how this functionalization of O-GlcNAc-modified proteins can be used to realize (1)-(3) above. Overall, these methods, which utilize commercially available reagents and standard protein analytical tools, will serve to advance our understanding of the diverse and important functions of O-GlcNAcylation. © 2018 Elsevier Inc. All rights reserved.

  19. Motion detection and correction for dynamic 15O-water myocardial perfusion PET studies

    International Nuclear Information System (INIS)

    Naum, Alexandru; Laaksonen, Marko S.; Oikonen, Vesa; Teraes, Mika; Jaervisalo, Mikko J.; Knuuti, Juhani; Tuunanen, Helena; Nuutila, Pirjo; Kemppainen, Jukka

    2005-01-01

    Patient motion during dynamic PET studies is a well-documented source of errors. The purpose of this study was to investigate the incidence of frame-to-frame motion in dynamic 15 O-water myocardial perfusion PET studies, to test the efficacy of motion correction methods and to study whether implementation of motion correction would have an impact on the perfusion results. We developed a motion detection procedure using external radioactive skin markers and frame-to-frame alignment. To evaluate motion, marker coordinates inside the field of view were determined in each frame for each study. The highest number of frames with identical spatial coordinates during the study were defined as ''non-moved''. Movement was considered present if even one marker changed position, by one pixel/frame compared with reference, in one axis, and such frames were defined as ''moved''. We tested manual, in-house-developed motion correction software and an automatic motion correction using a rigid body point model implemented in MIPAV (Medical Image Processing, Analysis and Visualisation) software. After motion correction, remaining motion was re-analysed. Myocardial blood flow (MBF) values were calculated for both non-corrected and motion-corrected datasets. At rest, patient motion was found in 18% of the frames, but during pharmacological stress the fraction increased to 45% and during physical exercise it rose to 80%. Both motion correction algorithms significantly decreased (p<0.006) the number of moved frames and the amplitude of motion (p<0.04). Motion correction significantly increased MBF results during bicycle exercise (p<0.02). At rest or during adenosine infusion, the motion correction had no significant effects on MBF values. Significant motion is a common phenomenon in dynamic cardiac studies during adenosine infusion but especially during exercise. Applying motion correction for the data acquired during exercise clearly changed the MBF results, indicating that motion

  20. Experimental study on detection of electrostatic discharges generated by polymer granules inside a metal silo

    Science.gov (United States)

    Choi, Kwangseok; Mogami, Tomofumi; Suzuki, Teruo

    2014-04-01

    To detect electrostatic discharges generated by polymer granules within a metal silo, we developed a novel and simple electrostatic discharge detector that utilizes a photosensor. The novel detector consists of a photosensor module in a metal cylinder, an optical band-pass filter, a quartz glass, a power supply, an amplifier for the photosensor module, and a digital oscilloscope. In this study, we conducted experiments at a real pneumatic powder transport facility that includes a metal silo to evaluate the novel detector using polypropylene granules. To determine the performance of the novel detector, we observed the electrostatic discharge within the metal silo using a conventional image intensifier system. The results obtained from the experiments show that the novel detector worked well in this study. The signals obtained with the novel detector were identical to the electrostatic discharges obtained with the conventional image intensifier system. The greatest advantage of this novel detector is that it is effective even when placed under external lights. In addition, the influence of various optical band-pass filters on the performance of the novel detector was discussed. Our study confirmed that an optical band-pass filter with a center wavelength of λ 330 nm (λ1/2: 315-345 nm) was the best performer among the optical band-pass filters used in this study.

  1. A feasibility study of stateful automaton packet inspection for streaming application detection systems

    Science.gov (United States)

    Tseng, Kuo-Kun; Lo, Jiao; Liu, Yiming; Chang, Shih-Hao; Merabti, Madjid; Ng, Felix, C. K.; Wu, C. H.

    2017-10-01

    The rapid development of the internet has brought huge benefits and social impacts; however, internet security has also become a great problem for users, since traditional approaches to packet classification cannot achieve satisfactory detection performance due to their low accuracy and efficiency. In this paper, a new stateful packet inspection method is introduced, which can be embedded in the network gateway and used by a streaming application detection system. This new detection method leverages the inexact automaton approach, using part of the header field and part of the application layer data of a packet. Based on this approach, an advanced detection system is proposed for streaming applications. The workflow of the system involves two stages: the training stage and the detection stage. In the training stage, the system initially captures characteristic patterns from a set of application packet flows. After this training is completed, the detection stage allows the user to detect the target application by capturing new application flows. This new detection approach is also evaluated using experimental analysis; the results of this analysis show that this new approach not only simplifies the management of the state detection system, but also improves the accuracy of data flow detection, making it feasible for real-world network applications.

  2. Quantitative analysis of stress thallium-201 studies: comparison of SPET and planar imaging in the detection of CAD

    International Nuclear Information System (INIS)

    Ziada, G.; Hayat, N.; Abdel-Dayem, H.M.; Hassan, I.

    1986-01-01

    The value of thallium-201 tomographic sections in the detection of coronary artery disease is illustrated by comparing visual interpretation (VTS) and quantitative analysis (QTS) with visual planar study (VPS) and quantitative analysis of planar study (QPS), referring to coronary angiography (CA) as the standard technique. It is concluded that visual assessment of single photon emission tomography (VTS) is more valuable than all other techniques (VPS, QPS and QTS) for detecting and localizing coronary artery disease. (UK)

  3. Asymmetrical flow field-flow fractionation with on-line detection for drug transfer studies: a feasibility study

    DEFF Research Database (Denmark)

    Hinna, A.; Steiniger, F.; Hupfeld, S.

    2014-01-01

    Knowledge about drug retention within colloidal carriers is of uppermost importance particularly if drug targeting is anticipated. The aim of the present study was to evaluate asymmetrical flow field-flow fractionation (AF4) with on-line UV/VIS drug quantification for its suitability to determine...... both release and transfer of drug from liposomal carriers to a model acceptor phase consisting of large liposomes. The hydrophobic porphyrin 5,10,15,20-tetrakis(4-hydroxyphenyl)21H,23H-porphine (p-THPP), a fluorescent dye with an absorbance maximum in the visible range and structural similarity...... channel geometries. Drug quantification by on-line absorbance measurements was established by comprehensive evaluation of the size-dependent turbidity contribution in on-line UV/VIS detection and by comparison with off-line results obtained for the respective dye-loaded donor formulations (dissolved...

  4. A Study to Determine the Biological Feasibility of a New Fish Tagging System : Annual Report 1990-1993.

    Energy Technology Data Exchange (ETDEWEB)

    Prentice, Earl F.; Maynard, D.J.; Downing, S.L. (and others)

    1994-01-01

    In 1983, the National Marine Fisheries Service (NMFS) began a multiyear cooperative research program with the Bonneville Power Administration (BPA) to evaluate a new miniaturized identification system that could be used with salmonids. The system is referred to as the passive-integrated-transponder (PIT) tagging and interrogation system. The program has focused on determining the effects of PIT tags on juvenile and adult salmonids, as well as the development and evaluation of tagging and interrogation methods. Earlier results of the program have been reported in annual reports and journal articles cited in this report. This report covers the work per formed from 1990 through 1993. For convenience, the report is divided into three sections: (1) Interrogation and separation systems at Columbia River Basin dams; (2) Systems development and evaluation; and (3) Information and technology transfer.

  5. Computerized detection of masses on mammograms: A comparative study of two algorithms

    International Nuclear Information System (INIS)

    Tiedeu, A.; Kom, G.; Kom, M.

    2007-02-01

    In this paper, we implement and carry out the comparison of two methods of computer-aided-detection of masses on mammograms. The two algorithms basically consist of 3 steps each: segmentation, binarization and noise suppression but using different techniques for each step. A database of 60 images was used to compare the performance of the two algorithms in terms of general detection efficiency, conservation of size and shape of detected masses. (author)

  6. Ultrasonography in Detection of Vaginal Foreign Bodies in Girls: A Retrospective Study.

    Science.gov (United States)

    Yang, Xiuzhen; Sun, Liying; Ye, Jingjing; Li, Xiaoying; Tao, Ran

    2017-12-01

    In this study we investigated the sonographic features of vaginal foreign bodies in girls and the diagnostic role of combined transperineal and transabdominal ultrasonography in the detection of vaginal foreign bodies in this population. DESIGN, SETTING, PARTICIPANTS, INTERVENTIONS, AND MAIN OUTCOME MEASURES: A retrospective review of the records of 249 girls seen in the outpatient pediatric and adolescent gynecology clinic of our hospital and referred to our department for sonographic evaluation of suspected vaginal foreign bodies between 2013 and 2016 was performed. All patients were transperineally and transabdominally scanned using an ultrasound machine with 3-MHz and 7.5-MHz transducers. The sonographic features of the detected foreign bodies were recorded and reported. All patients also underwent pelvic radiography. The presence of foreign bodies was confirmed using vaginoscopy. Two hundred forty-nine patients were included in this study, and vaginal foreign bodies were detected in 181 patients. Vaginal foreign bodies often present in girls aged from 2 to 12 years old. The most common vaginal foreign bodies were toilet paper, beads, small parts of toys, cap of water color brush, and crayons. The overall sensitivity, specificity, positive and negative predictive values of transperineal/transabdominal sonography in the diagnosis of vaginal foreign bodies were 81%, 53%, 82%, and 51%, respectively. The sensitivity, specificity, and positive and negative predictive values of transabdominal sonography were 33%, 49%, 63%, and 21%, respectively. The sensitivity, specificity, and positive and negative predictive values of transperineal sonography were 64%, 49%, 77%, and 33%, respectively. Abnormal findings were detected using x-ray in only 43 of the 181 cases (23.7%). The sensitivity, specificity, and positive and negative predictive values of x-ray were 24%, 91%, 88%, and 31%, respectively. The size of the foreign bodies ranged from 2 mm to 35 mm. For foreign

  7. Real-time porphyrin detection in plaque and caries: a case study

    Science.gov (United States)

    Timoshchuk, Mari-Alina I.; Ridge, Jeremy S.; Rugg, Amanda L.; Nelson, Leonard Y.; Kim, Amy S.; Seibel, Eric J.

    2015-02-01

    An ultrathin scanning fiber endoscope, originally developed for cancer diagnosis, was used in a case study to locate plaque and caries. The imaging system incorporated software mitigation of background auto-fluorescence (AF). In conventional fluorescence imaging, varying AF across a tooth surface can mask low-level porphyrin signals. Laser-induced auto-fluorescence signals of dental tissue excited using a 405-nm laser typically produce fluorescence over a wavelength range extending from 440-nm to 750-nm. Anaerobic bacterial metabolism produces various porphyrin species (eg. protoporphyrin IX) that are located in carious enamel, dentin, gingivitis sites, and plaque. In our case study, these porphyrin deposits remained as long as one day after prophylaxis. Imaging the tooth surface using 405-nm excitation and subtracting the natural AF enhances the image contrast of low-level porphyrin deposits, which would otherwise be masked by the high background AF. In a case study, healthy tissues as well as sites of early and advanced caries formations were scanned for visual and quantitative signs of red fluorescence associated with porphyrin species using a background mitigation algorithm. Initial findings show increasing amplitudes of red fluorescence as caries severity increases from early to late stages. Sites of plaque accumulation also displayed red fluorescence similar to that found in carious dental tissue. The use of real-time background mitigation of natural dental AF can enhance the detection of low porphyrin concentrations that are indicators of early stage caries formation.

  8. Red fluorescence imaging for dental plaque detection and quantification: pilot study

    Science.gov (United States)

    Liu, Zhao; Gomez, Juliana; Khan, Soniya; Peru, Debbie; Ellwood, Roger

    2017-09-01

    The red fluorescence of dental plaque originating from porphyrins in oral bacteria may allow visualization, detection, and scoring of plaque without disclosing agents. Two studies were conducted. The first included 24 healthy participants who abstained from oral hygiene for 24 h. Dental plaque was collected from tooth surfaces, and a 10% solution was prepared. These were scanned by a molecular spectrometer to identify the optimum excitation and emission wavelengths of plaque for developing a red fluorescence imaging system. Fourteen healthy subjects completed the second study. After a washout period (1 week), participants had a prophylaxis at baseline and abstained from oral hygiene during the study. They were monitored using the fluorescence imaging system at baseline, 24 h, and 48 h. A dentist clinically assessed plaque after disclosing and on red fluorescence images. Three descriptors were extracted from images and a RUSBoost classifier derived computer fluorescence scores through cross-validation. Red fluorescence plaque levels increased during the 48-h accumulation. Plaque progression was identified by dentist assessment and computer analysis, presenting significant differences between visits at tooth and subject levels (phygiene assessment.

  9. Initial study with Tc99m antigranulocyte antibody (MAK-47) in detection sources of infection

    International Nuclear Information System (INIS)

    Cwikla, J.B.; Buscombe, J.R.; Hilson, A.J.; Janoki, G.A.

    1997-01-01

    Antigranulocytes antibodies (AGAB) are antibodies directed against glycoprotein on the surface of granulocytes and as such provides in vivo cell labelling. They are easily labelled with Tc99m and comes a one step labelling technique. 20 patients have been studied 1 h and 4-6 hours after administration of 200 MBq of Tc99m AGAB (MAK-47). Less then 0.5 mg of antibody was given to each patients. Sites of uptake and outside of the reticular-endothelial system were reported as showing positive accumulation. Clinical results were confirmed by microbiological, pathological examinations, clinical follow-up and autopsy. There were 8 patients who had sites of infection confirmed by additional examination. All patients were visualized by Tc99m AGAB (MAK-47). There were 4 cases of osteomyelitis and septic arthritis and 4 cases of focal intra-abdominal infection. Two patients had uptake in non-infected/inflammatory arthritis, both in the knee. The remaining patients had true negative studies. The diagnostic accuracy of this study was as follows: sensitivity 100%, specificity 83%, positive predictive value (PPV) was 80% and negative predictive value (NPV) was 100%. Antigranulocyte antibody (MAK-47) seems to by promising tool in detecting focal infection in bone and soft tissue, except physiological accumulation in some parts of the body. It should be considered that antibodies can have non-specific uptake in non-infected, inflammation sites. It is easy to use and no had allergic reaction and HAMA antibody (human antimouse antibody). (author)

  10. Detection and characterization of interleukin-6 gene variants in Canis familiaris: association studies with periodontal disease.

    Science.gov (United States)

    Morinha, Francisco; Albuquerque, Carlos; Requicha, João; Dias, Isabel; Leitão, José; Gut, Ivo; Guedes-Pinto, Henrique; Viegas, Carlos; Bastos, Estela

    2011-10-10

    Periodontal disease (PD) is the most common inflammatory disease of the oral cavity of domestic carnivores. In Human Medicine molecular genetics research showed that several genes play a role in the predisposition and progression of this complex disease, primarily through the regulation of inflammatory mediators, but the exactly mechanisms are poorly understood. This study aims to contribute to the characterization of the genetic basis of PD in the dog, a classically accepted model in Periodontology. We searched for genetic variations in the interleukin-6 (IL6) gene, in order to verify its association with PD in a case-control study including 25 dogs in the PD case group and 45 dogs in the control group. We indentified and characterized three new genetic variations in IL6 gene. No statistically significant differences were detected between the control and PD cases groups. Our results do not support an evidence for a major role contribution of these variants in the susceptibility to PD in the analyzed population. Nevertheless, the sequence variant I/5_g.105G>A leads to an amino acid change (arginine to glutamine) and was predicted to be possibly damaging to the IL6 protein. A larger cohort and functional studies would be of extreme importance in a near future to understand the possible role of IL6 variants in this disease. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Study on Detection and Localization Algorithm of Traffic Signs from Natural Scenes

    Directory of Open Access Journals (Sweden)

    Xian-Zhong Han

    2014-08-01

    Full Text Available Automatic detection and location of traffic signs is an important part of intelligent transportation, especially for unmanned vehicle technology research. For the morphological feature of China road traffic signs, we propose a traffic sign detection method based on color segmentation and shape analysis. Firstly, in order to solve the problems of traffic signs color cast, distortion, and cross-color in natural scenes, the images are processed by white balance, Retinex color enhancement, and affine transformation. Then, the type of traffic signs is discriminated and detected, according to the color and shape characteristics of traffic signs. The experimental results show that this method can effectively detect and recognize traffic signs.

  12. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    International Nuclear Information System (INIS)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-01-01

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection

  13. Early Detection of Plant Equipment Failures: A Case Study in Just-in-Time Maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Parlos, Alexander G.; Kim, Kyusung; Bharadwaj, Raj M.

    2001-06-17

    The development and testing of a model-based fault detection system for electric motors is briefly presented. The fault detection system was developed using only motor nameplate information. The fault detection results presented utilize only motor voltage and current sensor information, minimizing the need for expensive or intrusive sensors. Dynamic recurrent neural networks are used to predict the input-output response of a three-phase induction motor while using an estimate of the motor speed signal. Multiresolution (or wavelet) signal-processing techniques are used in combination with more traditional methods to estimate fault features for use in winding insulation and motor mechanical and electromechanical failure detection.

  14. Simulation study of a hydrostat design for detecting underground leakage of water supply using neutron backscattering

    International Nuclear Information System (INIS)

    Kurosawa, Tadahiro; Nakamura, Takashi; Suzuki, Takashi; Okano, Yasuhiro; Chisaka, Haruo

    1998-01-01

    We have embarked upon the development of a new detection method for underground water leakage using a neutron backscattering system. We have estimated the performance capabilities of such a system using Monte Carlo simulation. It is indicated that a leak which results in 40% water content in the surrounding soils could be detected at depths of up to 40 cm from the surface to the center of the source of leakage. This new detection system could be useful as a hydrostat of underground water supply in noisy areas such as Tokyo, in place of presently-used hydrostats which are based on detection of changes in sound

  15. A comparative study of standard vs. high definition colonoscopy for adenoma and hyperplastic polyp detection with optimized withdrawal technique.

    Science.gov (United States)

    East, J E; Stavrindis, M; Thomas-Gibson, S; Guenther, T; Tekkis, P P; Saunders, B P

    2008-09-15

    Colonoscopy has a known miss rate for polyps and adenomas. High definition (HD) colonoscopes may allow detection of subtle mucosal change, potentially aiding detection of adenomas and hyperplastic polyps. To compare detection rates between HD and standard definition (SD) colonoscopy. Prospective, cohort study with optimized withdrawal technique (withdrawal time >6 min, antispasmodic, position changes, re-examining flexures and folds). One hundred and thirty patients attending for routine colonoscopy were examined with either SD (n = 72) or HD (n = 58) colonoscopes. Groups were well matched. Sixty per cent of patients had at least one adenoma detected with SD vs. 71% with HD, P = 0.20, relative risk (benefit) 1.32 (95% CI 0.85-2.04). Eighty-eight adenomas (mean +/- standard deviation 1.2 +/- 1.4) were detected using SD vs. 93 (1.6 +/- 1.5) with HD, P = 0.12; however more nonflat, diminutive (9 mm) hyperplastic polyps was 7% (0.09 +/- 0.36). High definition did not lead to a significant increase in adenoma or hyperplastic polyp detection, but may help where comprehensive lesion detection is paramount. High detection rates appear possible with either SD or HD, when using an optimized withdrawal technique.

  16. [Study on Ammonia Emission Rules in a Dairy Feedlot Based on Laser Spectroscopy Detection Method].

    Science.gov (United States)

    He, Ying; Zhang, Yu-jun; You, Kun; Wang, Li-ming; Gao, Yan-wei; Xu, Jin-feng; Gao, Zhi-ling; Ma, Wen-qi

    2016-03-01

    It needs on-line monitoring of ammonia concentration on dairy feedlot to disclose ammonia emissions characteristics accurately for reducing ammonia emissions and improving the ecological environment. The on-line monitoring system for ammonia concentration has been designed based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology combining with long open-path technology, then the study has been carried out with inverse dispersion technique and the system. The ammonia concentration in-situ has been detected and ammonia emission rules have been analyzed on a dairy feedlot in Baoding in autumn and winter of 2013. The monitoring indicated that the peak of ammonia concentration was 6.11 x 10(-6) in autumn, and that was 6.56 x 10(-6) in winter. The concentration results show that the variation of ammonia concentration had an obvious diurnal periodicity, and the general characteristic of diurnal variation was that the concentration was low in the daytime and was high at night. The ammonia emissions characteristic was obtained with inverse dispersion model that the peak of ammonia emissions velocity appeared at noon. The emission velocity was from 1.48 kg/head/hr to 130.6 kg/head/hr in autumn, and it was from 0.004 5 kg/head/hr to 43.32 kg/head/hr in winter which was lower than that in autumn. The results demonstrated ammonia emissions had certain seasonal differences in dairy feedlot scale. In conclusion, the ammonia concentration was detected with optical technology, and the ammonia emissions results were acquired by inverse dispersion model analysis with large range, high sensitivity, quick response without gas sampling. Thus, it's an effective method for ammonia emissions monitoring in dairy feedlot that provides technical support for scientific breeding.

  17. Nonintrusive tools to detect salts contamination in masonry: case study of Fontaine-Chaalis church

    Science.gov (United States)

    Giovannacci, David; Brissaud, Didier; Mertz, Jean-Didier; Mouhoubi, Kamel; Bodnar, Jean-Luc

    2017-07-01

    Such developments come from conservation experts in the community of cultural heritage - encompassing artworks, museum artifacts or historical monuments - for less intrusive and non-destructive tools to gain information about the subject. Increasingly the demand is for information regarding internal structures and indications of life histories and behaviors of an object. As it is well known, the deterioration due to the capillary rise of water through the walls is a very widespread problem. In this paper, a study of Stimulated Infrared thermography and Evanescent-Field Dielectrometry was applied to a non-destructive mapping, in situ, and in a semi-quantitative way the distribution of water, salt and the structural deterioration induced in a wall of the 13th century of the abbey's church of Chaalis. Complementarity of the both techniques will be underlined. The Stimulated Infra-Red Thermography (SIRT) is a contact free technique and allows the detection of plaster layers delamination of masonry. Evanescent-Field Dielectrometry (EFD) is a recent diagnostic method based on dielectric spectroscopy at microwave frequency. The measuring instrument is a portable resonant microwave device for mapping the water content and salinity on flat surface up to a depth of 2-3 cm in real time, in a non-destructive way. The method detects the water content and salt concentration in frescoes and walls by estimating the dielectric properties of tested porous materials that is viewed as a "binary" dielectric mixture consisting of bulk material and water, by the contrast between the dielectric constant of a dry material and water. According to the resolution of the optics, the SIRT has a less lateral resolution and more limited in depth, but it is easy to implement and can be used on-site, like in scaffolding conditions. Moreover, this technique gives an overview at a larger scale (metric) than EFD (centimetric).

  18. Study of MR sequence in detecting hyaline cartilage defects of the knee joint

    International Nuclear Information System (INIS)

    Li Songbai; He Cuiju; Sun Wenge; Li Chunkui; Qi Xixun; Li Yanliang; Xu Ke; Bai Xizhuang; Wu Zhenhua

    2003-01-01

    Objective: To evaluate the value of various MR imaging sequences for detecting hyaline cartilage defects. Methods: Ten animal models of cartilage defect were established in 5 pig knees. 5 knees were examined with nine different MR sequences. The signal noise ratio of cartilage and contrast noise ratio were calculated and compared between cartilage and adjacent tissue. Measurement of the defect depth and width on the imaging was correlated with the actual measurement before imaging. 23 patients with hyaline cartilage defects of the knee were evaluated with MR imaging. All these patients underwent subsequent arthroscopy. MR imaging protocol included the selected sequences in the experimental study. Results: The cartilage SNR was better in FSE PD, FS 3D FSPGR, and FS FSE PD sequences. CNR between cartilage and subcartilaginous bone was best in FS 3D FSPGR and FS FSE PD sequences. CNR between cartilage and joint fluid was best in FS 3D FSPGR and FS FSE T 2 WI sequences. CNR between cartilage and meniscus and ligament was best in FS 3D FSPGR, FS FSE PD, SE T 1 WI, and IR TI700 sequences. CNR between cartilage and fat was best in FS 3D FSPGR and SE T 1 WI sequences. The width and depth correlation was best in IR TI700 sequence, which showed the statistical significance (P 2 WI sequence, 68%, 99%, and 0.74, respectively with IR TI700 sequence. Conclusion: The sensitivity of FS 3D FSPGR sequence in detecting hyaline cartilage defect is the highest. T 1 WI of spin echo sequence and T 2 WI/PDWI of fast spin-echo with fat saturation should be the standard sequence in the examination of knee joint. T 1 WI of IR sequence has potential clinical value for cartilage examination

  19. Detection of antibodies against Paracoccidioides brasiliensis melanin in in vitro and in vivo studies during infection.

    Science.gov (United States)

    Urán, Martha E; Nosanchuk, Joshua D; Restrepo, Angela; Hamilton, Andrew J; Gómez, Beatriz L; Cano, Luz E

    2011-10-01

    Several cell wall constituents, including melanins or melanin-like compounds, have been implicated in the pathogenesis of a wide variety of microbial diseases caused by diverse species of pathogenic bacteria, fungi, and helminthes. Among these microorganisms, the dimorphic fungal pathogen Paracoccidioides brasiliensis produces melanin in its conidial and yeast forms. In the present study, melanin particles from P. brasiliensis were injected into BALB/c mice in order to produce monoclonal antibodies (MAbs). We identified five immunoglobulin G1 (IgG1) κ-chain and four IgM melanin-binding MAbs. The five IgG1 κ-chain isotypes are the first melanin-binding IgG MAbs ever reported. The nine MAbs labeled P. brasiliensis conidia and yeast cells both in vitro and in pulmonary tissues. The MAbs cross-reacted with melanin-like purified particles from other fungi and also with commercial melanins, such as synthetic and Sepia officinalis melanin. Melanization during paracoccidioidomycosis (PCM) was also further supported by the detection of IgG antibodies reactive to melanin from P. brasiliensis conidia and yeast in sera and bronchoalveolar lavage fluids from P. brasiliensis-infected mice, as well as in sera from human patients with PCM. Serum specimens from patients with other mycoses were also tested for melanin-binding antibodies by enzyme-linked immunosorbent assay, and cross-reactivities were detected for melanin particles from different fungal sources. These results suggest that melanin from P. brasiliensis is an immunologically active fungal structure that activates a strong IgG humoral response in humans and mice.

  20. Whole Genome Association Study to Detect Single Nucleotide Polymorphisms for Behavior in Sapsaree Dog (

    Directory of Open Access Journals (Sweden)

    J. H. Ha

    2015-07-01

    Full Text Available The purpose of this study was to characterize genetic architecture of behavior patterns in Sapsaree dogs. The breed population (n = 8,256 has been constructed since 1990 over 12 generations and managed at the Sapsaree Breeding Research Institute, Gyeongsan, Korea. Seven behavioral traits were investigated for 882 individuals. The traits were classified as a quantitative or a categorical group, and heritabilities (h2 and variance components were estimated under the Animal model using ASREML 2.0 software program. In general, the h2 estimates of the traits ranged between 0.00 and 0.16. Strong genetic (rG and phenotypic (rP correlations were observed between nerve stability, affability and adaptability, i.e. 0.9 to 0.94 and 0.46 to 0.68, respectively. To detect significant single nucleotide polymorphism (SNP for the behavioral traits, a total of 134 and 60 samples were genotyped using the Illumina 22K CanineSNP20 and 170K CanineHD bead chips, respectively. Two datasets comprising 60 (Sap60 and 183 (Sap183 samples were analyzed, respectively, of which the latter was based on the SNPs that were embedded on both the 22K and 170K chips. To perform genome-wide association analysis, each SNP was considered with the residuals of each phenotype that were adjusted for sex and year of birth as fixed effects. A least squares based single marker regression analysis was followed by a stepwise regression procedure for the significant SNPs (p<0.01, to determine a best set of SNPs for each trait. A total of 41 SNPs were detected with the Sap183 samples for the behavior traits. The significant SNPs need to be verified using other samples, so as to be utilized to improve behavior traits via marker-assisted selection in the Sapsaree population.

  1. Visual attention measures predict pedestrian detection in central field loss: a pilot study.

    Science.gov (United States)

    Alberti, Concetta F; Horowitz, Todd; Bronstad, P Matthew; Bowers, Alex R

    2014-01-01

    The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT) and static attention (Useful Field of View; UFOV) were predictive of the ability of people with central field loss (CFL) to detect pedestrian hazards in simulated driving. 11 people with bilateral CFL (visual acuity 20/30-20/200) and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT) and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests). Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision). UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse) (84% and 97%, respectively; p = 0.001). For CFL participants, higher proportions of timely reactions correlated significantly with higher (better) MOT speed thresholds (r = 0.73, p = 0.01), with better performance on the UFOV divided and selective attention subtests (r = -0.66 and -0.62, respectively, pattention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks.

  2. A combination test for detection of gene-environment interaction in cohort studies.

    Science.gov (United States)

    Coombes, Brandon; Basu, Saonli; McGue, Matt

    2017-07-01

    Identifying gene-environment (G-E) interactions can contribute to a better understanding of disease etiology, which may help researchers develop disease prevention strategies and interventions. One big criticism of studying G-E interaction is the lack of power due to sample size. Studies often restrict the interaction search to the top few hundred hits from a genome-wide association study or focus on potential candidate genes. In this paper, we test interactions between a candidate gene and an environmental factor to improve power by analyzing multiple variants within a gene. We extend recently developed score statistic based genetic association testing approaches to the G-E interaction testing problem. We also propose tests for interaction using gene-based summary measures that pool variants together. Although it has recently been shown that these summary measures can be biased and may lead to inflated type I error, we show that under several realistic scenarios, we can still provide valid tests of interaction. These tests use significantly less degrees of freedom and thus can have much higher power to detect interaction. Additionally, we demonstrate that the iSeq-aSum-min test, which combines a gene-based summary measure test, iSeq-aSum-G, and an interaction-based summary measure test, iSeq-aSum-I, provides a powerful alternative to test G-E interaction. We demonstrate the performance of these approaches using simulation studies and illustrate their performance to study interaction between the SNPs in several candidate genes and family climate environment on alcohol consumption using the Minnesota Center for Twin and Family Research dataset. © 2017 WILEY PERIODICALS, INC.

  3. The New Worlds Observer: Direct Detection and Study of Exoplanets from the Habitable Zone Outward

    Science.gov (United States)

    Cash, Webster C.; New Worlds Study Team

    2009-01-01

    Direct detection and spectroscopic study of the planets around the nearby stars is generally recognized as a prime goal of astronomy. The New Worlds Observer mission concept is being studied as an Astrophysics Strategic Mission Concept Study for this purpose. NWO features two spacecraft: a general purpose 4m telescope that operates from the UV to the Near IR, and a starshade, a flower-shaped occulter about 50m in diameter flying in alignment about 70,000km away. Our study shows this is the most effective way to map nearby planetary systems. Images will show dust and debris down to a fraction of our zodiacal light level. Planets fainter than the Earth can be seen from the Habitable Zone outward, at distances up to 20pc. High throughput and low noise enable immediate follow-up spectroscopy of discovered planets. NWO can discover many more Earth-like planets than all competing approaches including astrometric, interferometric, and internal coronagraphic. Within hours of discovery, a high quality spectrum can determine the true nature of the exoplanet and open the search for biomarkers and life. Over half of the time will be spent with the starshade in transit to the next target. During those times the telescope will be available to for general astrophysics purposes. Operating from the ultraviolet to the near infrared, this will be a true HST follow-on. The study shows all needed technologies already exist. The cost scales primarily with telescope size. The mission is definitely within the financial and technical reach of NASA for the coming decade.

  4. Improving Focal Depth Estimates: Studies of Depth Phase Detection at Regional Distances

    Science.gov (United States)

    Stroujkova, A.; Reiter, D. T.; Shumway, R. H.

    2006-12-01

    The accurate estimation of the depth of small, regionally recorded events continues to be an important and difficult explosion monitoring research problem. Depth phases (free surface reflections) are the primary tool that seismologists use to constrain the depth of a seismic event. When depth phases from an event are detected, an accurate source depth is easily found by using the delay times of the depth phases relative to the P wave and a velocity profile near the source. Cepstral techniques, including cepstral F-statistics, represent a class of methods designed for the depth-phase detection and identification; however, they offer only a moderate level of success at epicentral distances less than 15°. This is due to complexities in the Pn coda, which can lead to numerous false detections in addition to the true phase detection. Therefore, cepstral methods cannot be used independently to reliably identify depth phases. Other evidence, such as apparent velocities, amplitudes and frequency content, must be used to confirm whether the phase is truly a depth phase. In this study we used a variety of array methods to estimate apparent phase velocities and arrival azimuths, including beam-forming, semblance analysis, MUltiple SIgnal Classification (MUSIC) (e.g., Schmidt, 1979), and cross-correlation (e.g., Cansi, 1995; Tibuleac and Herrin, 1997). To facilitate the processing and comparison of results, we developed a MATLAB-based processing tool, which allows application of all of these techniques (i.e., augmented cepstral processing) in a single environment. The main objective of this research was to combine the results of three focal-depth estimation techniques and their associated standard errors into a statistically valid unified depth estimate. The three techniques include: 1. Direct focal depth estimate from the depth-phase arrival times picked via augmented cepstral processing. 2. Hypocenter location from direct and surface-reflected arrivals observed on sparse

  5. An experimental study of UWB device-free person detection and ranging

    NARCIS (Netherlands)

    Kilic, Y.; Wymeersch, Henk; Meijerink, Arjan; Bentum, Marinus Jan; Scanlon, W.G.

    2013-01-01

    Passive person detection and localization is an emerging area in UWB localization systems, whereby people are not required to carry any UWB ranging device. Based on experimental data, we propose a novel method to detect static persons in the absence of template waveforms, and to compute distances to

  6. Oxidative stress and pathogenic attack in plants, studied by laser based photoacoustic trace gas detection

    NARCIS (Netherlands)

    Santosa, Ignatius Edi

    2002-01-01

    Photoacoustic detection has proven to be a sensitive method, which is suitable for trace gas measurement. In this thesis, we improved the photoacoustic detection system to measure new biologically interesting gases, ethane (C2H6) and nitric oxide (NO). A new design of grating holder is incorporated

  7. Natural history of breast cancers detected in the Swedish mammography screening programme: a cohort study

    DEFF Research Database (Denmark)

    Zahl, Per-Henrik; Gøtzsche, Peter C; Mæhlen, Jan

    2011-01-01

    The natural history of screen-detected breast cancers is not well understood. A previous analysis of the incidence change during the introduction of the Norwegian screening programme in the late 1990s suggested that the natural history of many screen-detected invasive breast cancers is to regress...

  8. On the Evaluation of Outlier Detection: Measures, Datasets, and an Empirical Study Continued

    DEFF Research Database (Denmark)

    Campos, G. O.; Zimek, A.; Sander, J.

    2016-01-01

    The evaluation of unsupervised outlier detection algorithms is a constant challenge in data mining research. Little is known regarding the strengths and weaknesses of different standard outlier detection models, and the impact of parameter choices for these algorithms. The scarcity of appropriate...... are available online in the repository at: http://www.dbs.ifi.lmu.de/research/outlier-evaluation/...

  9. Understanding environmental DNA detection probabilities: A case study using a stream-dwelling char Salvelinus fontinalis

    Science.gov (United States)

    Taylor M. Wilcox; Kevin S. McKelvey; Michael K. Young; Adam J. Sepulveda; Bradley B. Shepard; Stephen F. Jane; Andrew R. Whiteley; Winsor H. Lowe; Michael K. Schwartz

    2016-01-01

    Environmental DNA sampling (eDNA) has emerged as a powerful tool for detecting aquatic animals. Previous research suggests that eDNA methods are substantially more sensitive than traditional sampling. However, the factors influencing eDNA detection and the resulting sampling costs are still not well understood. Here we use multiple experiments to derive...

  10. Detecting SYN flood attacks via statistical monitoring charts: A comparative study

    KAUST Repository

    Bouyeddou, Benamar; Harrou, Fouzi; Sun, Ying; Kadri, Benamar

    2017-01-01

    Accurate detection of cyber-attacks plays a central role in safeguarding computer networks and information systems. This paper addresses the problem of detecting SYN flood attacks, which are the most popular Denial of Service (DoS) attacks. Here, we

  11. On resilience studies of system detection and recovery techniques against stealthy insider attacks

    Science.gov (United States)

    Wei, Sixiao; Zhang, Hanlin; Chen, Genshe; Shen, Dan; Yu, Wei; Pham, Khanh D.; Blasch, Erik P.; Cruz, Jose B.

    2016-05-01

    With the explosive growth of network technologies, insider attacks have become a major concern to business operations that largely rely on computer networks. To better detect insider attacks that marginally manipulate network traffic over time, and to recover the system from attacks, in this paper we implement a temporal-based detection scheme using the sequential hypothesis testing technique. Two hypothetical states are considered: the null hypothesis that the collected information is from benign historical traffic and the alternative hypothesis that the network is under attack. The objective of such a detection scheme is to recognize the change within the shortest time by comparing the two defined hypotheses. In addition, once the attack is detected, a server migration-based system recovery scheme can be triggered to recover the system to the state prior to the attack. To understand mitigation of insider attacks, a multi-functional web display of the detection analysis was developed for real-time analytic. Experiments using real-world traffic traces evaluate the effectiveness of Detection System and Recovery (DeSyAR) scheme. The evaluation data validates the detection scheme based on sequential hypothesis testing and the server migration-based system recovery scheme can perform well in effectively detecting insider attacks and recovering the system under attack.

  12. A microcosting study of diagnostic tests for the detection of coronary artery disease in the Netherlands

    International Nuclear Information System (INIS)

    Tan, S.S.; Oppe, M.; Zoet-Nugteren, S.K.; Niezen, R.A.; Kofflard, M.J.M.; Ten Cate, F.J.; Roijen, L. Hakkaart-van

    2009-01-01

    Objective: The primary aim of the present study was to calculate the actual costs of four diagnostic tests for the detection of coronary artery disease in the Netherlands using a microcosting methodology. As a secondary objective, the cost effectiveness of eight diagnostic strategies was examined, using microcosting and reimbursement fees subsequently as the cost estimate. Design: A multicenter, retrospective cost analysis from a hospital perspective. Setting: The study was conducted in three general hospitals in the Netherlands for 2006. Interventions: Exercise electrocardiography (exECG), stress echocardiography (sECHO), single-photon emission computed tomography (SPECT) and coronary angiography (CA). Results: The actual costs of exECG, sECHO, SPECT and CA were Euro 33, 216, 614 and 1300 respectively. For all diagnostic tests, labour and indirect cost components (overheads and capital) together accounted for over 75% of the total costs. Consumables played a relatively important role in SPECT (14%). Hotel and nutrition were only applicable to SPECT and CA. Diagnostic services were solely performed for CA, but their costs were negligible (2%). Using microcosting estimates, exECG-sECHO-SPECT-CA was the most and CA the least cost effective strategy ( Euro 397 and 1302 per accurately diagnosed patient). Using reimbursement fees, exECG-sECHO-CA was most and SPECT-CA least cost effective ( Euro 147 and 567 per accurately diagnosed patient). Conclusions: The use of microcosting estimates instead of reimbursement fees led to different conclusions regarding the relative cost effectiveness of alternative strategies.

  13. Validation of a knowledge-based boundary detection algorithm: a multicenter study

    International Nuclear Information System (INIS)

    Groch, M.W.; Erwin, W.D.; Murphy, P.H.; Ali, A.; Moore, W.; Ford, P.; Qian Jianzhong; Barnett, C.A.; Lette, J.

    1996-01-01

    A completely operator-independent boundary detection algorithm for multigated blood pool (MGBP) studies has been evaluated at four medical centers. The knowledge-based boundary detector (KBBD) algorithm is nondeterministic, utilizing a priori domain knowledge in the form of rule sets for the localization of cardiac chambers and image features, providing a case-by-case method for the identification and boundary definition of the left ventricle (LV). The nondeterministic algorithm employs multiple processing pathways, where KBBD rules have been designed for conventional (CONV) imaging geometries (nominal 45 LAO, nonzoom) as well as for highly zoomed and/or caudally tilted (ZOOM) studies. The resultant ejection fractions (LVEF) from the KBBD program have been compared with the standard LVEF calculations in 253 total cases in four institutions, 157 utilizing CONV geometry and 96 utilizing ZOOM geometries. The criteria for success was a KBBD boundary adequately defined over the LV as judged by an experienced observer, and the correlation of KBBD LVEFs to the standard calculation of LVEFs for the institution. The overall success rate for all institutions combined was 99.2%, with an overall correlation coefficient of r=0.95 (P<0.001). The individual success rates and EF correlations (r), for CONV and ZOOM geometers were: 98%, r=0.93 (CONV) and 100%, r=0.95 (ZOOM). The KBBD algorithm can be adapted to varying clinical situations, employing automatic processing using artificial intelligence, with performance close to that of a human operator. (orig.)

  14. Detecting Interplanetary Dust Particles with Radars to Study the Dynamics at the Edge of the Space

    Science.gov (United States)

    Janches, Diego

    2015-01-01

    The Earth's mesosphere is the region of the atmosphere between approximately 60-120 km altitude, where the transition from hydrodynamic flow to molecular diffusion occurs. It is highly dynamic region where turbulence by wave braking is produced and energy is deposited from sources from both, below and above this altitude range. Because aircraft and nearly all balloons reach altitudes below approximately 50 km and orbital spacecrafts are well above approximately 400 km, the mesosphere has only been accessed through the use of sounding rockets or remote sensing techniques, and as a result, it is the most poorly understood part of the atmosphere. In addition, millions of Interplanetary Dust Particles (IDPs) enter the atmosphere. Within the mesosphere most of these IDPs melt or vaporize as a result of collisions with the air particles producing meteors that can be detected with radars. This provides a mean to study the dynamics of this region. In this lecture the basic principles of the utilization of meteor radars to study the dynamics of the mesosphere will be presented. A system overview of these systems will be provided as well as discuss the advantages/disadvantages of these systems, provide details of the data processing methodology and give a brief overview of the current status of the field as well as the vision for the next decade.

  15. A Study of Storage Ring Requirements for an Explosive Detection System Using NRA Method.

    Energy Technology Data Exchange (ETDEWEB)

    Wang, T. F. (Tai-Sen F.); Kwan, T. J. T. (Thomas J. T.)

    2005-01-01

    The technical feasibility of an explosives detection system based on the nuclear resonance absorption (NRA) of gamma rays in nitrogen-rich materials was demonstrated at Los Alamos National Laboratory (LANL) in 1993 by using an RFQ proton accelerator and a tomographic imaging prototype. The study is being continued recently to examine deployment of such an active interrogation system in realistic scenarios. The approach is to use an accelerator and electron-cooling-equipped storage rings(s) to provide the high quality and high current proton beam needed in a practical application. In this work, we investigate the requirements on the storage ring(s) with external gamma-ray-production target for a variant of the airport luggage inspection system considered in the earlier LANL experiments. Estimations are carried out based on the required inspection throughput, the gamma ray yield, the proton beam emittance growth due to scatters with the photon-production target, beam current limit in the storage ring, and the electron-cooling rate. Studies using scaling and reasonable parameter values indicate that it is possible to use no more than a few storage rings per inspection station in a practical NRA luggage inspection complex having more than ten inspection stations.

  16. Microwave Radiometers for Fire Detection in Trains: Theory and Feasibility Study

    Directory of Open Access Journals (Sweden)

    Federico Alimenti

    2016-06-01

    Full Text Available This paper introduces the theory of fire detection in moving vehicles by microwave radiometers. The system analysis is discussed and a feasibility study is illustrated on the basis of two implementation hypotheses. The basic idea is to have a fixed radiometer and to look inside the glass windows of the wagon when it passes in front of the instrument antenna. The proposed sensor uses a three-pixel multi-beam configuration that allows an image to be formed by the movement of the train itself. Each pixel is constituted by a direct amplification microwave receiver operating at 31.4 GHz. At this frequency, the antenna can be a 34 cm offset parabolic dish, whereas a 1 K brightness temperature resolution is achievable with an overall system noise figure of 6 dB, an observation bandwidth of 2 GHz and an integration time of 1 ms. The effect of the detector noise is also investigated and several implementation hypotheses are discussed. The presented study is important since it could be applied to the automatic fire alarm in trains and moving vehicles with dielectric wall/windows.

  17. Anthropometric and performance measures to study talent detection in youth volleyball.

    Science.gov (United States)

    Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia

    2017-12-01

    The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.

  18. An experimental study of 99Tcm-HL91 in detection of myocardial viability

    International Nuclear Information System (INIS)

    Xu Tao; Liu Baoping; Meng Yubao; Sun Bingqi; Niu Guangjun; Han Xingmin; Yuan Qiao

    2005-01-01

    Objective: To investigate whether 99 Tc m -4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime (HL91) can be used to distinguish ischemic myocardium segments from infarction segments. Methods: Twenty-five acute myocardial infarction patients (≤6 weeks) and 5 old myocardial infarction patients (> 6 weeks) were included in the study. All the study patients underwent 99 Tc m -HL91 and 99 Tc m -methoxyisobutylisonitrile (MIBI) imaging intervented and unintervented with nitroglycerin, and the myocardium segments were divided into three groups according to 99 Tc m -MIBI imaging results: normal, ischemic, and infarction myocardium segments. The difference of the radial counts of 99 Tc m -HL91 in three groups were analyzed after the imaging with 99 Tc m -HL91. Results: 1) In acute myocardial infarction patients, the accumulation rates of 99 Tc m -HL91 was 95% in normal segment group, 157% in ischemic group, 93% in infarction group. The accumulation rates of 99 Tc m -HL91 in the ischemic group was higher than that in the normal group and infarction group. 2)In old myocardial infarction patients, the accumulation rates of 99 Tc m -HL91 were of no difference among the normal, ischemic, and infarction groups. Conclusion: 99 Tc m -HL91 is a potential marker for detecting the ischemic myocardial tissue. (authors)

  19. Snake scales, partial exposure, and the Snake Detection Theory: A human event-related potentials study

    Science.gov (United States)

    Van Strien, Jan W.; Isbell, Lynne A.

    2017-01-01

    Studies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to partially exposed snake models and scale patterns on the snake skin. Here, we examined whether snake skin patterns and partially exposed snakes elicit a larger EPN in humans. In Task 1, we employed pictures with close-ups of snake skins, lizard skins, and bird plumage. In task 2, we employed pictures of partially exposed snakes, lizards, and birds. Participants watched a random rapid serial visual presentation of these pictures. The EPN was scored as the mean activity (225–300 ms after picture onset) at occipital and parieto-occipital electrodes. Consistent with previous studies, and with the Snake Detection Theory, the EPN was significantly larger for snake skin pictures than for lizard skin and bird plumage pictures, and for lizard skin pictures than for bird plumage pictures. Likewise, the EPN was larger for partially exposed snakes than for partially exposed lizards and birds. The results suggest that the EPN snake effect is partly driven by snake skin scale patterns which are otherwise rare in nature. PMID:28387376

  20. Study and optimization of the ionisation channel in the Edelweiss dark matter direct detection experiment

    International Nuclear Information System (INIS)

    Censier, B.

    2006-02-01

    The EDELWEISS experiment is aiming at the detection of Weakly Interactive Massive Particles (WIMPs), today's most favoured candidates for solving the dark matter issue. Background ionising particles are identified thanks to the simultaneous measurement of heat and ionisation in the detectors. The main limitation to this method is coming from the ionisation measurement, charge collection being less efficient in some part of the detectors known as 'dead' areas. The specificity of the measurement is due to the use of very low temperatures and low collection fields. This thesis is dedicated to the study of carrier trapping. It involves time-resolved charge measurements as well as a simulation code adapted to the specific physical conditions. We first present results concerning charge trapping at the free surfaces of the detectors. Our method allows to build a surface-charge in a controlled manner by irradiation with a strong radioactive source. This charge is then characterised with a weaker source which acts as a probe. In a second part of the work, bulk-trapping characteristics are deduced from charge collection efficiency measurements, and by an original method based on event localisation in the detector. The results show that a large proportion of the doping impurities are ionised, as indicated independently by the study of degradation by space-charge build-up. In this last part, near-electrodes areas are found to contain large densities of charged trapping centres, in connection with dead-layer effects. (author)

  1. Experimental Studies on Damage Detection in Frame Structures Using Vibration Measurements

    Directory of Open Access Journals (Sweden)

    Giancarlo Fraraccio

    2010-01-01

    Full Text Available This paper presents an experimental study of frequency and time domain identification algorithms and discusses their effectiveness in structural health monitoring of frame structures using acceleration input and response data. Three algorithms were considered: 1 a frequency domain decomposition algorithm (FDD, 2 a time domain Observer Kalman IDentification algorithm (OKID, and 3 a subsequent physical parameter identification algorithm (MLK. Through experimental testing of a four-story steel frame model on a uniaxial shake table, the inherent complications of physical instrumentation and testing are explored. Primarily, this study aims to provide a dependable first-order and second-order identification of said test structure in a fully instrumented state. Once the characteristics (i.e. the stiffness matrix for a benchmark structure have been determined, structural damage can be detected by a change in the identified structural stiffness matrix. This work also analyzes the stability of the identified structural stiffness matrix with respect to fluctuations of input excitation magnitude and frequency content in an experimental setting.

  2. A study of the early detection of insect infestations and density/distribution of host plants. [Rio Grande

    Science.gov (United States)

    Hart, W. G. (Principal Investigator); Ingle, S. J.; Davis, M. R.

    1975-01-01

    The author has identified the following significant results. With comparative observations of film types and seasonal influences on reflectance characteristics, many crop varieties can be identified. This study shows that citrus, sugar cane, brush, some winter vegetables, and grain crops could be identified. Vegetative patterns in border areas can be detected. This information can be useful in detecting avenues of entry of pest species and areas of stress that require vigilance in stopping the spread of destructive species. Influence of some environmental factors on crops that may be confused with pest injury, or related factors, can be detected and identified with Skylab data (S-190B).

  3. Evaluation of Modification of the 3M™ Molecular Detection Assay (MDA) Salmonella Method (2013.09) for the Detection of Salmonella in Selected Foods: Collaborative Study.

    Science.gov (United States)

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathon; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2014-01-01

    The 3M(™) Molecular Detection Assay (MDA) Salmonella utilizes isothermal amplification of nucleic acid sequences with high specificity, efficiency, rapidity and bioluminescence to detect amplification of Salmonella spp. in food, food-related, and environmental samples after enrichment. A method modification and matrix extension study of the previously approved AOAC Official Method(SM) 2013.09 was conducted, and approval of the modification was received on March 20, 2014. Using an unpaired study design in a multilaboratory collaborative study, the 3M MDA Salmonella method was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.05 (2011), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish Products for raw ground beef and the U.S. Food and Drug Administration (FDA)/Bacteriological Analytical Manual (BAM) Chapter 5, Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the LPODs of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were

  4. Detection of genetically modified rice: Collaborative validation study of a PCR based detection of genetically modified rice Oryza sativa commercially available in Saudi Arabia

    OpenAIRE

    Ibrahim, Mohamed; Alaraidh, Ibrahim; Amid, Azura; Farouk, Abd-El Aziem; Bazaid, Salih; Greiner, Ralf; Alghunaim, Abdullah

    2011-01-01

    A collaborative trial study has been conducted for validation of an extraction method and a subsequent PCR for  the detection of transgenic rice sold in Saudi Arabia. The tests were carried out in Saudi Arabia using Real-Time PCR and the positive samples were validated in another lab in Malaysia using PCR and agarose gel visualization.  The samples were tested for the existence of the NOS Terminator. A total of 150 samples were tested out of which three samples tested positi...

  5. Spatiotemporal Change Detection Using Landsat Imagery: the Case Study of Karacabey Flooded Forest, Bursa, Turkey

    Science.gov (United States)

    Akay, A. E.; Gencal, B.; Taş, İ.

    2017-11-01

    This short paper aims to detect spatiotemporal detection of land use/land cover change within Karacabey Flooded Forest region. Change detection analysis applied to Landsat 5 TM images representing July 2000 and a Landsat 8 OLI representing June 2017. Various image processing tools were implemented using ERDAS 9.2, ArcGIS 10.4.1, and ENVI programs to conduct spatiotemporal change detection over these two images such as band selection, corrections, subset, classification, recoding, accuracy assessment, and change detection analysis. Image classification revealed that there are five significant land use/land cover types, including forest, flooded forest, swamp, water, and other lands (i.e. agriculture, sand, roads, settlement, and open areas). The results indicated that there was increase in flooded forest, water, and other lands, while the cover of forest and swamp decreased.

  6. Study to Determine the Biological Feasibility of a New Fish Tagging System, 1998-2000 Progress Report.

    Energy Technology Data Exchange (ETDEWEB)

    Downing, Sandra L.

    2001-05-01

    Since 1984, the National Marine Fisheries Service (NMFS) in cooperation with the Bonneville Power Administration (BPA) has conducted an ongoing research and development project to expand and improve technology for Passive-Integrated-Transponder tags (PIT tags) throughout the Columbia River Basin (CRB). Work conducted as part of this project during 1999-2000 was divided into six individual projects, which are covered separately in this report.

  7. Psychotic Experiences and Working Memory: A Population-Based Study Using Signal-Detection Analysis.

    Directory of Open Access Journals (Sweden)

    Rodolfo Rossi

    Full Text Available Psychotic Experiences (PEs during adolescence index increased risk for psychotic disorders and schizophrenia in adult life. Working memory (WM deficits are a core feature of these disorders. Our objective was to examine the relationship between PEs and WM in a general population sample of young people in a case control study. 4744 individuals of age 17-18 from Bristol and surrounding areas (UK were analyzed in a cross-sectional study nested within the Avon Longitudinal Study of Parents and Children (ALSPAC birth cohort study. The dependent variable was PEs, assessed using the semi-structured Psychosis-Like Symptom Interview (PLIKSi. The independent variable was performance on a computerized numerical n-back working memory task. Signal-Detection Theory indices, including standardized hits rate, false alarms rate, discriminability index (d' and response bias (c from 2-Back and 3-Back tasks were calculated. 3576 and 3527 individuals had complete data for 2-Back and 3-Back respectively. Suspected/definite PEs prevalence was 7.9% (N = 374. Strongest evidence of association was seen between PEs and false alarms on the 2-Back, (odds ratio (OR = 1.17 [95% confidence intervals (CI 1.01, 1.35] and 3-back (OR = 1.35 [1.18, 1.54] and with c (OR = 1.59 [1.09, 2.34], and lower d' (OR = 0.76 [0.65, 0.89], on the 3-Back. Adjustment for several potential confounders, including general IQ, drug exposure and different psycho-social factors, and subsequent multiple imputation of missing data did not materially alter the results. WM is impaired in young people with PEs in the general population. False alarms, rather than poor accuracy, are more closely related to PEs. Such impairment is consistent with different neuropsychological models of psychosis focusing on signal-to-noise discrimination, probabilistic reasoning and impaired reality monitoring as a basis of psychotic symptoms.

  8. Remote sensing and spatial analysis based study for detecting deforestation and the associated drivers

    Science.gov (United States)

    El-Abbas, Mustafa M.; Csaplovics, Elmar; Deafalla, Taisser H.

    2013-10-01

    Nowadays, remote-sensing technologies are becoming increasingly interlinked to the issue of deforestation. They offer a systematized and objective strategy to document, understand and simulate the deforestation process and its associated causes. In this context, the main goal of this study, conducted in the Blue Nile region of Sudan, in which most of the natural habitats were dramatically destroyed, was to develop spatial methodologies to assess the deforestation dynamics and its associated factors. To achieve that, optical multispectral satellite scenes (i.e., ASTER and LANDSAT) integrated with field survey in addition to multiple data sources were used for the analyses. Spatiotemporal Object Based Image Analysis (STOBIA) was applied to assess the change dynamics within the period of study. Broadly, the above mentioned analyses include; Object Based (OB) classifications, post-classification change detection, data fusion, information extraction and spatial analysis. Hierarchical multi-scale segmentation thresholds were applied and each class was delimited with semantic meanings by a set of rules associated with membership functions. Consequently, the fused multi-temporal data were introduced to create detailed objects of change classes from the input LU/LC classes. The dynamic changes were quantified and spatially located as well as the spatial and contextual relations from adjacent areas were analyzed. The main finding of the present study is that, the forest areas were drastically decreased, while the agrarian structure in conversion of forest into agricultural fields and grassland was the main force of deforestation. In contrast, the capability of the area to recover was clearly observed. The study concludes with a brief assessment of an 'oriented' framework, focused on the alarming areas where serious dynamics are located and where urgent plans and interventions are most critical, guided with potential solutions based on the identified driving forces.

  9. True Detective

    OpenAIRE

    Gajhede, Andreas; Westmark, [No Value; Bantoulidis, Georgios

    2016-01-01

    This paper examines the HBO’s television-series True Detective, a 2014 crime drama, attempting to point out the central elements of detective-fiction, to be found in its narrative. True Detective narrative is a heavy text with a number of references from various well-known, non-adjacent texts within the field of weird fiction, horror fiction and detective fiction. Therefore, the case study of this research will focus on narratological and literary analysis, in order to discover the predominan...

  10. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    Science.gov (United States)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  11. Value of esophagus cinescintigraphy in adult patients (study of esophageal transit and detection of gastroesophageal reflux. Investigation of 52 patients

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, J.; Sauvan, R.; Dupin, B.; Guidicelli, R.; Fuentes, P.; Reboud, E.

    1985-01-01

    Using scintigraphic techniques oesophageal transit was studied in 47 patients and gastro-oesophageal reflux was evaluated in 41 patients. The comparison of these investigations with oesophageal manometry, acid reflux test and endoscopy emphasized the value of the simple and noninvasive scintigraphic methods. Radionuclide oesophageal transit detected a higher incidence of esophageal motor abnormality than the other methods. Gastroesophageal (GE) scintiscanning detected GE reflux accurately, rapidly and with greater sensitivity than the other diagnostic techniques.

  12. Value of esophagus cinescintigraphy in adult patients (study of esophageal transit and detection of gastroesophageal reflux). Investigation of 52 patients

    International Nuclear Information System (INIS)

    Pasquier, J.; Sauvan, R.; Dupin, B.; Guidicelli, R.; Fuentes, P.; Reboud, E.

    1985-01-01

    Using scintigraphic techniques oesophageal transit was studied in 47 patients and gastro-oesophageal reflux was evaluated in 41 patients. The comparison of these investigations with oesophageal manometry, acid reflux test and endoscopy emphasized the value of the simple and noninvasive scintigraphic methods. Radionuclide oesophageal transit detected a higher incidence of esophageal motor abnormality than the other methods. Gastroesophageal (GE) scintiscanning detected GE reflux accurately, rapidly and with greater sensitivity than the other diagnostic techniques [fr

  13. Shallow Transits—Deep Learning. I. Feasibility Study of Deep Learning to Detect Periodic Transits of Exoplanets

    Science.gov (United States)

    Zucker, Shay; Giryes, Raja

    2018-04-01

    Transits of habitable planets around solar-like stars are expected to be shallow, and to have long periods, which means low information content. The current bottleneck in the detection of such transits is caused in large part by the presence of red (correlated) noise in the light curves obtained from the dedicated space telescopes. Based on the groundbreaking results deep learning achieves in many signal and image processing applications, we propose to use deep neural networks to solve this problem. We present a feasibility study, in which we applied a convolutional neural network on a simulated training set. The training set comprised light curves received from a hypothetical high-cadence space-based telescope. We simulated the red noise by using Gaussian Processes with a wide variety of hyper-parameters. We then tested the network on a completely different test set simulated in the same way. Our study proves that very difficult cases can indeed be detected. Furthermore, we show how detection trends can be studied and detection biases quantified. We have also checked the robustness of the neural-network performance against practical artifacts such as outliers and discontinuities, which are known to affect space-based high-cadence light curves. Future work will allow us to use the neural networks to characterize the transit model and identify individual transits. This new approach will certainly be an indispensable tool for the detection of habitable planets in the future planet-detection space missions such as PLATO.

  14. An experimental study on damage detection of structures using a timber beam

    International Nuclear Information System (INIS)

    Choi, Fook Choon; Li, Jianchun; Samali, Bijan; Crews, Keith

    2007-01-01

    Using vibration methods for the damage detection and structural health monitoring in bridge structures is rapidly developing. However, very little work has so far been reported on timber bridges. This paper intends to address such shortcomings by experimental investigation on a timber beam using a vibration based method to detect damage. A promising damage detection algorithm based on modal strain energy was adopted and modified to locate/evaluate damage. A laboratory investigation was conducted on a timber beam inflicted with various damage scenarios using modal tests. The modal parameters obtained from the undamaged and damaged state of the test beam were used in the computation of damage index, were then applied using a damage detection algorithm utilising modal strain energy and a statistical approach to detect location of damage. A mode shape reconstruction technique was used to enhance the capability of the damage detection algorithm with limited number of sensors. The test results and analysis show that location of damage can be accurately identified with limited sensors. The modified method is less dependent on the number of modes selected and can detect damage with a higher degree of confidence

  15. A study of earthquake-induced building detection by object oriented classification approach

    Science.gov (United States)

    Sabuncu, Asli; Damla Uca Avci, Zehra; Sunar, Filiz

    2017-04-01

    Among the natural hazards, earthquakes are the most destructive disasters and cause huge loss of lives, heavily infrastructure damages and great financial losses every year all around the world. According to the statistics about the earthquakes, more than a million earthquakes occur which is equal to two earthquakes per minute in the world. Natural disasters have brought more than 780.000 deaths approximately % 60 of all mortality is due to the earthquakes after 2001. A great earthquake took place at 38.75 N 43.36 E in the eastern part of Turkey in Van Province on On October 23th, 2011. 604 people died and about 4000 buildings seriously damaged and collapsed after this earthquake. In recent years, the use of object oriented classification approach based on different object features, such as spectral, textural, shape and spatial information, has gained importance and became widespread for the classification of high-resolution satellite images and orthophotos. The motivation of this study is to detect the collapsed buildings and debris areas after the earthquake by using very high-resolution satellite images and orthophotos with the object oriented classification and also see how well remote sensing technology was carried out in determining the collapsed buildings. In this study, two different land surfaces were selected as homogenous and heterogeneous case study areas. In the first step of application, multi-resolution segmentation was applied and optimum parameters were selected to obtain the objects in each area after testing different color/shape and compactness/smoothness values. In the next step, two different classification approaches, namely "supervised" and "unsupervised" approaches were applied and their classification performances were compared. Object-based Image Analysis (OBIA) was performed using e-Cognition software.

  16. An empirical study to detect effective factors to increase number of moviegoers

    Directory of Open Access Journals (Sweden)

    Yasaman Giyahi

    2012-08-01

    Full Text Available In this paper, we present an empirical study to detect important factors, which could increase the number of moviegoers. The study distributes a questionnaire among different people at four age groups including 35.2% (men, and 64.8% (women, most of them are single (between 21 to 30 years living at 3- to 4-member families, holding BA degree with 4 to 7 million Rials monthly salary. Inferential statistics tests, including Kolmogorov–Smirnov, binominal or ratio, Chi Square and Friedman, show that type of story, genre and artists, casts are considered as the most important factors in selection of film while quality of sound, seat comfort, ventilation of cinema hall are regarded as the most important factors in selection of cinema. In addition, cinema is not predominant pastime or hobby of individuals during holidays and existence of more attractive pastimes than cinema is the most important factor, which hinders individuals from going to cinema. Individuals go to cinema fewer than three times a year, primarily during the afternoon of holidays at the weekend. TV teasers and word of mouth advertisements are the most significant publicity tools for those individuals who intend to go to cinema halls. These two factors, i.e. TV teasers and word of mouth advertisements, are the most significant sources of studying individuals for the selection of film. Individuals almost select their favorite movies before going to cinema and if ticket is finished at the box office of cinema, they suspend watching film in another time and finally, they re-plan watching film. It should be noted that satisfaction of individuals from cinema is much more effective than their satisfaction from film.

  17. Study of cumulative fatigue damage detection for used parts with nonlinear output frequency response functions based on NARMAX modelling

    Science.gov (United States)

    Huang, Honglan; Mao, Hanying; Mao, Hanling; Zheng, Weixue; Huang, Zhenfeng; Li, Xinxin; Wang, Xianghong

    2017-12-01

    Cumulative fatigue damage detection for used parts plays a key role in the process of remanufacturing engineering and is related to the service safety of the remanufactured parts. In light of the nonlinear properties of used parts caused by cumulative fatigue damage, the based nonlinear output frequency response functions detection approach offers a breakthrough to solve this key problem. First, a modified PSO-adaptive lasso algorithm is introduced to improve the accuracy of the NARMAX model under impulse hammer excitation, and then, an effective new algorithm is derived to estimate the nonlinear output frequency response functions under rectangular pulse excitation, and a based nonlinear output frequency response functions index is introduced to detect the cumulative fatigue damage in used parts. Then, a novel damage detection approach that integrates the NARMAX model and the rectangular pulse is proposed for nonlinear output frequency response functions identification and cumulative fatigue damage detection of used parts. Finally, experimental studies of fatigued plate specimens and used connecting rod parts are conducted to verify the validity of the novel approach. The obtained results reveal that the new approach can detect cumulative fatigue damages of used parts effectively and efficiently and that the various values of the based nonlinear output frequency response functions index can be used to detect the different fatigue damages or working time. Since the proposed new approach can extract nonlinear properties of systems by only a single excitation of the inspected system, it shows great promise for use in remanufacturing engineering applications.

  18. Inversion Algorithms and PS Detection in SAR Tomography, Case Study of Bucharest City

    Directory of Open Access Journals (Sweden)

    C. Dănişor

    2016-06-01

    Full Text Available Synthetic Aperture Radar (SAR tomography can reconstruct the elevation profile of each pixel based on a set of co-registered complex images of a scene. Its main advantage over classical interferometric methods consists in the capability to improve the detection of single persistent scatterers as well as to enable the detection of multiple scatterers interfering within the same pixel. In this paper, three tomographic algorithms are compared and applied to a dataset of 32 images to generate the elevation map of dominant scatterers from a scene. Targets which present stable proprieties over time - Persistent Scatterers (PS are then detected based on reflectivity functions reconstructed with Capon filtering.

  19. A qualitative study examining the experience of primary care dentists in the detection and management of potentially malignant lesions. 1. Factors influencing detection and the decision to refer.

    Science.gov (United States)

    Brocklehurst, P R; Baker, S R; Speight, P M

    2010-01-23

    Many oral squamous cell carcinomas present as late stage disease and so the detection of early and pre-malignancy is considered to be of paramount importance. The majority of research examining primary care dentists' experience of the detection and management of early disease has been undertaken using questionnaires, with the inherent bias this introduces. The aim of this study was to use qualitative methods to develop a richer account of practitioners' views about screening and what factors influence the decision to refer a patient. Semi-structured interviews were undertaken with eighteen dentists in Sheffield, transcribed and analysed using thematic analysis. Ten codes were identified according to the aims of the study and organized into four overarching themes. Although many dentists were screening regularly, some did not appear to be adopting a rigorous and systematic approach. A number of participants also placed more reliance on 'classical' presentations rather than the more varied presentation of potentially malignant lesions and were more influenced by the clinical history of the lesion rather than risk factors. Overall, the present research suggests that for some dentists, more rigour is required when examining for early disease.

  20. Detecting rater bias using a person-fit statistic: a Monte Carlo simulation study.

    Science.gov (United States)

    Aubin, André-Sébastien; St-Onge, Christina; Renaud, Jean-Sébastien

    2018-04-01

    With the Standards voicing concern for the appropriateness of response processes, we need to explore strategies that would allow us to identify inappropriate rater response processes. Although certain statistics can be used to help detect rater bias, their use is complicated by either a lack of data about their actual power to detect rater bias or the difficulty related to their application in the context of health professions education. This exploratory study aimed to establish the worthiness of pursuing the use of l z to detect rater bias. We conducted a Monte Carlo simulation study to investigate the power of a specific detection statistic, that is: the standardized likelihood l z person-fit statistics (PFS). Our primary outcome was the detection rate of biased raters, namely: raters whom we manipulated into being either stringent (giving lower scores) or lenient (giving higher scores), using the l z statistic while controlling for the number of biased raters in a sample (6 levels) and the rate of bias per rater (6 levels). Overall, stringent raters (M = 0.84, SD = 0.23) were easier to detect than lenient raters (M = 0.31, SD = 0.28). More biased raters were easier to detect then less biased raters (60% bias: 62, SD = 0.37; 10% bias: 43, SD = 0.36). The PFS l z seems to offer an interesting potential to identify biased raters. We observed detection rates as high as 90% for stringent raters, for whom we manipulated more than half their checklist. Although we observed very interesting results, we cannot generalize these results to the use of PFS with estimated item/station parameters or real data. Such studies should be conducted to assess the feasibility of using PFS to identify rater bias.

  1. Detection of a random signal in a multi-channel environment: a performance study

    International Nuclear Information System (INIS)

    Frenzel, K.Z.

    1986-01-01

    Performance of the optimal (likelihood ratio) test and suboptimal tests, including the normalized cross correlator and two energy detectors are compared for problems involving non-gaussian as well as gaussian statistics. Also, optimal one-channel processing is compared to optimal two-channel processing for equivalent total signal-to-noise ratios. Receiver operator characteristics (ROC) curves obtained by a combination of simulation and analytic methods are used to evaluate the performance of the processors. It was found that two-channel processing helps the detection performance the most when the noise levels are uncertain. This was true for all signal and noise densities studied. In cases where the noise levels and channel attenuations are known, or when only the attenuations are uncertain, the performance using optimal one-channel processing was close to that found using optimal two-channel processing. When comparing optimal processors to the three suboptimal processors, it was found that when the noise level in each channel is very uncertain, the performance of the normalized cross correlator is much closer to the optimal than that of either of the energy detectors. If, however, the noise levels are know with a fair degree of certainty, the performance of the energy detectors improves considerably, in some cases approaching the optimal performance

  2. Shear wave elastography for detection of prostate cancer: A preliminary study

    International Nuclear Information System (INIS)

    Woo, Sung Min; Kim, Sang Youn; Cho, Jeong Yeon; KIm, Seung Hyup

    2014-01-01

    To assess the diagnostic value of shear wave elastography (SWE) for prostate cancer detection. In this retrospective study, 87 patients with the suspicion of prostate cancer (prostate-specific antigen > 4 ng/mL and abnormal digital rectal examination) underwent a protocol-based systematic 12-core biopsy followed by targeted biopsy at hypoechoic areas on grey-scale ultrasound. Prior to biopsy, SWE was performed by placing two circular 5 mm-sized regions of interest (ROIs) along the estimated biopsy tract in each sector and one ROI for hypoechoic lesions. SWE parameters, S (mean stiffness) and R (mean stiffness ratio), were calculated and compared regarding different histopathologic tissues and their accuracy for diagnosing prostate cancer was analyzed. SWE parameters were correlated with Gleason score and were compared between indolent ( 43.9 kPa and 60.8%, 66.4%, and 0.653, respectively, for R > 3. Both, S and R showed a significant correlation with Gleason score (r ≥ 0.296, p ≤ 0.008) and were significantly different between indolent and aggressive prostate cancer (p ≤ 0.006). Shear wave elastographic parameters are significantly different between prostate cancer and benign prostate tissue and correlate with Gleason score.

  3. Detection of rib fractures in an abused infant using digital radiography: a laboratory study

    International Nuclear Information System (INIS)

    Kleinman, Paul K.; O'Connor, Brian; Nimkin, Katherine; Rayder, Shawn M.; Spevak, Melissa R.; Belanger, Patricia L.; Getty, David J.; Karellas, Andrew

    2002-01-01

    To assess the diagnostic performance of digital radiography using charge-coupled device (CCD) technology in the detection of rib fracture in infant abuse.Materials and methods. Four fractured posterior rib arcs and eight normal ribs removed at autopsy from a 10-month-old abused infant were radiographed using a CCD prototype, four clinical film-screen systems, and direct-exposure film. Each rib was viewed with these six systems in nine different projections. The resultant 648 images were assessed for probability of fracture (0-100%) by four pediatric radiologists. The calculated area under the resultant ROC curves (A z ) for the CCD was compared with those obtained with direct-exposure, high-detail, medium and fast film-screen radiographic systems. The mean A z for the CCD (0.937) fell within the range of the high-detail systems (0.934-0.940) and was significantly higher (p 20 line pairs per millimeter) the CCD performance was comparable (A z =0.944 vs. 0.937). The similar performance can be explained by the higher contrast resolution of the digital technology. This study indicates that in the ex vivo setting, digital radiology can perform comparably to high-detail film-screen imaging. The findings suggest that digital radiography has the potential to replace film-screen imaging in the evaluation of inflicted skeletal injury in infants. (orig.)

  4. A study on the artificial interproximal caries detection with the digital radiography

    International Nuclear Information System (INIS)

    Kwon, Ki Jeong; Hwang, Eui Hwan; Lee, Sang Rae

    1994-01-01

    The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit -DX compatible, video camera (VM-S8200, Hitachi Co., Japan), and color monitor (Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC (analog to digital converter) was used, and spatial resolution has 256 gray levels. The obtained results were as follows: 1. at the condition of under exposure, the radiographs were superior to the images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with the normal enamel.

  5. Preliminary Study of 13C/12C Application for the Detection of Adulterated Honey

    International Nuclear Information System (INIS)

    Loestanatjaroen, S.

    2014-01-01

    Honey and pollen in natural products derived from the same plant both share the same carbon source; as a result their 13 C isotope signature should be identical. The majority of honey adulteration in Thailand was done particularly by adding cheap sugars such as high sucrose cane syrup (HSCS). The accepted differences in 13 C/ 12 C between honey and its associated protein extract is -1δ/ο deviation, which provides the international benchmark of 7% C4 sugar addition. This study reports the preliminary detection of adulterated Thai honey samples by using isotope ratio mass spectrometer coupled to elemental analyzer (EAIRMS). The 5 Thailand honey samples and the pure honey were adulterated with HSCS dilution as: 0, 0.5, 1, 5, 7, 10, 15 and 50%, respectively. The results were found that two of the Thai honey samples and of 10, 15, and 50% dilution were adulterated. The result of analyzed cane sugar of ten replicates were found -11.2 and -10.8 δdeviation, respectively.

  6. Probability of detection - Comparative study of computed and film radiography for high-energy applications

    International Nuclear Information System (INIS)

    Venkatachalam, R.; Venugopal, M.; Prasad, T.

    2007-01-01

    Full text of publication follows: Suitability of computed radiography with Ir-192, Co-60 and up to 9 MeV x-rays for weld inspections is of importance to many heavy engineering and aerospace industries. CR is preferred because of lesser exposure and processing time as compared to film based radiography and also digital images offers other advantages such as image enhancements, quantitative measurements and easier archival. This paper describes systemic experimental approaches and image quality metrics to compare imaging performance of CR with film-based radiography. Experiments were designed using six-sigma methodology to validate performance of CR for steel thickness up to 160 mm with Ir- 192, Co-60 and x-ray energies varying from 100 kV up to 9 MeV. Weld specimens with defects such as lack of fusion, penetration, cracks, concavity, and porosities were studied for evaluating radiographic sensitivity and imaging performance of the system. Attempts were also made to quantify probability of detection using specimens with artificial and natural defects for various experimental conditions and were compared with film based systems. (authors)

  7. A Comparative Study of Anomaly Detection Techniques for Smart City Wireless Sensor Networks.

    Science.gov (United States)

    Garcia-Font, Victor; Garrigues, Carles; Rifà-Pous, Helena

    2016-06-13

    In many countries around the world, smart cities are becoming a reality. These cities contribute to improving citizens' quality of life by providing services that are normally based on data extracted from wireless sensor networks (WSN) and other elements of the Internet of Things. Additionally, public administration uses these smart city data to increase its efficiency, to reduce costs and to provide additional services. However, the information received at smart city data centers is not always accurate, because WSNs are sometimes prone to error and are exposed to physical and computer attacks. In this article, we use real data from the smart city of Barcelona to simulate WSNs and implement typical attacks. Then, we compare frequently used anomaly detection techniques to disclose these attacks. We evaluate the algorithms under different requirements on the available network status information. As a result of this study, we conclude that one-class Support Vector Machines is the most appropriate technique. We achieve a true positive rate at least 56% higher than the rates achieved with the other compared techniques in a scenario with a maximum false positive rate of 5% and a 26% higher in a scenario with a false positive rate of 15%.

  8. Vision-based Detection of Acoustic Timed Events: a Case Study on Clarinet Note Onsets

    Science.gov (United States)

    Bazzica, A.; van Gemert, J. C.; Liem, C. C. S.; Hanjalic, A.

    2017-05-01

    Acoustic events often have a visual counterpart. Knowledge of visual information can aid the understanding of complex auditory scenes, even when only a stereo mixdown is available in the audio domain, \\eg identifying which musicians are playing in large musical ensembles. In this paper, we consider a vision-based approach to note onset detection. As a case study we focus on challenging, real-world clarinetist videos and carry out preliminary experiments on a 3D convolutional neural network based on multiple streams and purposely avoiding temporal pooling. We release an audiovisual dataset with 4.5 hours of clarinetist videos together with cleaned annotations which include about 36,000 onsets and the coordinates for a number of salient points and regions of interest. By performing several training trials on our dataset, we learned that the problem is challenging. We found that the CNN model is highly sensitive to the optimization algorithm and hyper-parameters, and that treating the problem as binary classification may prevent the joint optimization of precision and recall. To encourage further research, we publicly share our dataset, annotations and all models and detail which issues we came across during our preliminary experiments.

  9. A study of soil moisture variability for landmine detection by the neutron technique

    Directory of Open Access Journals (Sweden)

    Avdić Senada

    2007-01-01

    Full Text Available This paper is focused on the space and temporal variability of soil moisture experimental data acquired at a few locations near landmine fields in the Tuzla Canton, as well as on the quantification of the statistical nature of soil moisture data on a small spatial scale. Measurements of soil water content at the surface were performed by an electro-magnetic sensor over 1 25, and 100 m2 grids, at intervals of 0.2, 0.5, and 1 m, respectively. The sampling of soil moisture at different spatial resolutions and over different grid sizes has been investigated in order to achieve the quantification of the statistical nature of soil moisture distribution. The statistical characterization of spatial variability was performed through variogram and correlogram analysis of measurement results. The temporal variability of the said samples was examined over a two-season period. For both sampling periods, the spatial correlation length is about 1 to 2 m, respectively, or less. Thus, sampling should be done on a larger spatial scale, in order to capture the variability of the investigated areas. Since the characteristics of many landmine sensors depend on soil moisture, the results of this study could form a useful data base for multisensor landmine detection systems with a promising performance.

  10. Non-invasive detection of periodontal disease using diffuse reflectance spectroscopy: a clinical study

    Science.gov (United States)

    Prasanth, Chandra Sekhar; Betsy, Joseph; Subhash, Narayanan; Jayanthi, Jayaraj L.; Prasanthila, Janam

    2012-03-01

    In clinical diagnostic procedures, gingival inflammation is considered as the initial stage of periodontal breakdown. This is often detected clinically by bleeding on probing as it is an objective measure of inflammation. Since conventional diagnostic procedures have several inherent drawbacks, development of novel non-invasive diagnostic techniques assumes significance. This clinical study was carried out in 15 healthy volunteers and 25 patients to demonstrate the applicability of diffuse reflectance (DR) spectroscopy for quantification and discrimination of various stages of inflammatory conditions in periodontal disease. The DR spectra of diseased lesions recorded using a point monitoring system consisting of a tungsten halogen lamp and a fiber-optic spectrometer showed oxygenated hemoglobin absorption dips at 545 and 575 nm. Mean DR spectra on normalization shows marked differences between healthy and different stages of gingival inflammation. Among the various DR intensity ratios investigated, involving oxy Hb absorption peaks, the R620/R575 ratio was found to be a good parameter of gingival inflammation. In order to screen the entire diseased area and its surroundings instantaneously, DR images were recorded with an EMCCD camera at 620 and 575 nm. We have observed that using the DR image intensity ratio R620/R575 mild inflammatory tissues could be discriminated from healthy with a sensitivity of 92% and specificity of 93%, and from moderate with a sensitivity of 83% and specificity of 96%. The sensitivity and specificity obtained between moderate and severe inflammation are 82% and 76% respectively.

  11. Experimental study on visual detection for fatigue of fixed-position staff.

    Science.gov (United States)

    Nie, Baisheng; Huang, Xin; Chen, Yang; Li, Anjin; Zhang, Ruming; Huang, Jinxin

    2017-11-01

    Fatigue can lead to decreased work performance and poorer safety and health condition. Fatigue is ubiquitous in production and in life, while the research on it is mainly concentrated in the automotive driving, aircraft piloting and other fields, and it is insufficient to study on the fatigue of fixed-position staff. This paper puts forward a non-contact visual image method, which can monitor the extent of fatigue of fixed-position staff. Fatigue threshold used in judgment is obtained by processing the recorded data of visual images of the experimental subjects when fatiguing and by analyzing eye closure time, percentage of eyelid closure (PERCLOS) value, frequency and number of blinks. The results show that there is significant difference among the four indicators before and after experiment subjects undergo fatigue. The fatigue of experimental subjects is obvious when eye closure time is 3.5 s/min, PERCLOS value 6%, and blink frequency 0.4 times/s. This provides a reference for a wider range of detection of fatigue and a method for avoiding mistakes and accidents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Automatic detection of hemorrhagic pericardial effusion on PMCT using deep learning - a feasibility study.

    Science.gov (United States)

    Ebert, Lars C; Heimer, Jakob; Schweitzer, Wolf; Sieberth, Till; Leipner, Anja; Thali, Michael; Ampanozi, Garyfalia

    2017-12-01

    Post mortem computed tomography (PMCT) can be used as a triage tool to better identify cases with a possibly non-natural cause of death, especially when high caseloads make it impossible to perform autopsies on all cases. Substantial data can be generated by modern medical scanners, especially in a forensic setting where the entire body is documented at high resolution. A solution for the resulting issues could be the use of deep learning techniques for automatic analysis of radiological images. In this article, we wanted to test the feasibility of such methods for forensic imaging by hypothesizing that deep learning methods can detect and segment a hemopericardium in PMCT. For deep learning image analysis software, we used the ViDi Suite 2.0. We retrospectively selected 28 cases with, and 24 cases without, hemopericardium. Based on these data, we trained two separate deep learning networks. The first one classified images into hemopericardium/not hemopericardium, and the second one segmented the blood content. We randomly selected 50% of the data for training and 50% for validation. This process was repeated 20 times. The best performing classification network classified all cases of hemopericardium from the validation images correctly with only a few false positives. The best performing segmentation network would tend to underestimate the amount of blood in the pericardium, which is the case for most networks. This is the first study that shows that deep learning has potential for automated image analysis of radiological images in forensic medicine.

  13. Face repetition detection and social interest: An ERP study in adults with and without Williams syndrome.

    Science.gov (United States)

    Key, Alexandra P; Dykens, Elisabeth M

    2016-12-01

    The present study examined possible neural mechanisms underlying increased social interest in persons with Williams syndrome (WS). Visual event-related potentials (ERPs) during passive viewing were used to compare incidental memory traces for repeated vs. single presentations of previously unfamiliar social (faces) and nonsocial (houses) images in 26 adults with WS and 26 typical adults. Results indicated that participants with WS developed familiarity with the repeated faces and houses (frontal N400 response), but only typical adults evidenced the parietal old/new effect (previously associated with stimulus recollection) for the repeated faces. There was also no evidence of exceptional salience of social information in WS, as ERP markers of memory for repeated faces vs. houses were not significantly different. Thus, while persons with WS exhibit behavioral evidence of increased social interest, their processing of social information in the absence of specific instructions may be relatively superficial. The ERP evidence of face repetition detection in WS was independent of IQ and the earlier perceptual differentiation of social vs. nonsocial stimuli. Large individual differences in ERPs of participants with WS may provide valuable information for understanding the WS phenotype and have relevance for educational and treatment purposes.

  14. Study of Behavior and detection of radon in environmental samples by scintillation method. Application for radium

    International Nuclear Information System (INIS)

    ZAFIMANJATO, J.L.R.

    2007-01-01

    Radon is considered as the major source of radiological exposure of natural radiations to the population. On an international scale, it represents about the half of exposures of natural radiation sources (UNSCEAR, 1993) Radon gets into human body with inhaled air and sometimes with drinking water. Then, the objective of this work is to know the radon concentrations in water and in indoor atmosphere, and the risk in order to set up a method of monitoring and to identify high radon level areas. A specific method of detection using liquid scintillation with special emphasis on α/β discrimination, the use of solvent extractive and enrichment of radionuclides have been developed for the determination of both 222 Rn and 226 Ra in water. The method is simple, rapid and sensitive. In a pilot project for a monitoring of drinking water in Madagascar, it was shown that the proposed method was suitable for a large scale monitoring and routine analysis. Considerable concentrations of radon were found in water and air samples from Vinaninkarena. Radon concentrations obtained by in situ and in laboratory measurements have been compared to the results of an international intercomparison campaigns organised by the German Society for Liquid Scintillation Spectrometry in 2011. A theoretical study of the behavior of radon is porous material containing radium is detailed in order to describe its exhalation phenomena. An assessment model of the dose due to ingestion and liberation of radon from water is presented and compared with other models especially to the Crawford Brown's model. [fr

  15. A Comparative Study of Anomaly Detection Techniques for Smart City Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Victor Garcia-Font

    2016-06-01

    Full Text Available In many countries around the world, smart cities are becoming a reality. These cities contribute to improving citizens’ quality of life by providing services that are normally based on data extracted from wireless sensor networks (WSN and other elements of the Internet of Things. Additionally, public administration uses these smart city data to increase its efficiency, to reduce costs and to provide additional services. However, the information received at smart city data centers is not always accurate, because WSNs are sometimes prone to error and are exposed to physical and computer attacks. In this article, we use real data from the smart city of Barcelona to simulate WSNs and implement typical attacks. Then, we compare frequently used anomaly detection techniques to disclose these attacks. We evaluate the algorithms under different requirements on the available network status information. As a result of this study, we conclude that one-class Support Vector Machines is the most appropriate technique. We achieve a true positive rate at least 56% higher than the rates achieved with the other compared techniques in a scenario with a maximum false positive rate of 5% and a 26% higher in a scenario with a false positive rate of 15%.

  16. Detecting hepatic steatosis using ultrasound-induced thermal strain imaging: an ex vivo animal study

    International Nuclear Information System (INIS)

    Mahmoud, Ahmed M; Ding, Xuan; Dutta, Debaditya; Kim, Kang; Singh, Vijay P

    2014-01-01

    ± 0.037%). Using histology as a gold standard to classify mouse livers, US-TSI had a sensitivity and specificity of 70% and 90%, respectively. The area under the receiver operating characteristic curve was 0.775. This ex vivo study demonstrates the feasibility of using US-TSI to detect fatty livers and warrants further investigation of US-TSI as a diagnostic tool for hepatic steatosis. (paper)

  17. Part I: A comparative study of bismuth-modified screen-printed electrodes for lead detection

    Energy Technology Data Exchange (ETDEWEB)

    Calvo Quintana, Josefina [Dipartimento di Scienze e Tecnologie Chimiche, Universita di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome (Italy); Consorzio Interuniversitario Biostrutture e Biosistemi ' INBB' , Viale Medaglie d' Oro 305, 00136 Rome (Italy); Arduini, Fabiana, E-mail: fabiana.arduini@uniroma2.it [Dipartimento di Scienze e Tecnologie Chimiche, Universita di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome (Italy); Consorzio Interuniversitario Biostrutture e Biosistemi ' INBB' , Viale Medaglie d' Oro 305, 00136 Rome (Italy); Amine, Aziz [Faculte des Sciences et Techniques, B.P.146, Mohammadia, Morocco, Rome (Italy); Punzo, Francesco; Destri, Giovanni Li [LAMSUN and CSGI at Dipartimento di Scienze Chimiche, Universita degli Studi di Catania, Viale A. Doria 6, 95125, Catania (Italy); Bianchini, Chiara [Dipartimento di Ingegneria Chimica Materiali Ambienti dell' Universita degli Studi ' La Sapienza' di Roma, via Eudossiana 18, 00184 Rome (Italy); Zane, Daniela; Curulli, Antonella [Istituto per lo Studio dei Materiali Nanostrutturati (ISMN)-CNR,via del Castro Laurenziano 7, 00161 Rome (Italy); Palleschi, Giuseppe; Moscone, Danila [Dipartimento di Scienze e Tecnologie Chimiche, Universita di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome (Italy); Consorzio Interuniversitario Biostrutture e Biosistemi ' INBB' , Viale Medaglie d' Oro 305, 00136 Rome (Italy)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer 'In situ' Bi-SPE has higher sensitivity than 'ex situ' Bi-SPE and 'Bi{sub 2}O{sub 3} bulk' SPE. Black-Right-Pointing-Pointer Electrochemical treatment of SPE before Bi film deposition allows one to reach low LOD. Black-Right-Pointing-Pointer The linearity of Pb{sup 2+} in HCl and HClO{sub 4} is greatly affected by the ionic strength. Black-Right-Pointing-Pointer Satisfactory values of the recovery percentage were obtained in drinking water samples. - Abstract: Lead determination was carried out in the frame of the European Union project Biocop ( (www.biocop.org)) using a bismuth-modified screen-printed electrode (Bi-SPE) and the stripping analysis technique. In order to choose a sensitive Bi-SPE for lead detection, an analytical comparative study of electrodes modified by Bi using 'in situ', 'ex situ' and 'bulk' procedures was carried out. On the basis of the results obtained, we confirmed that the 'in situ' procedure resulted in better analytical performances with respect to not only 'ex situ' but also to 'Bi{sub 2}O{sub 3} bulk' modified electrodes, allowing for a linear range of lead ion concentration from 0.5 to 100 {mu}g L{sup -1} and a detection limit of 0.15 {mu}g L{sup -1}. We demonstrated that, before the Bi film deposition, an oxidative electrochemical pre-treatment of the working electrode could be useful because it eliminates traces of lead in the graphite-ink, as shown with stripping measurements. It also improves the electrochemical performance of the electrodes as demonstrated with Electrochemical Impedance Spectroscopy (EIS) measurements. The influence of different analytical parameters, such as the electrolyte solution composition (acetate buffer, chloridric acid, nitric acid, perchloric acid) and the ionic strength was investigated in order to evaluate how to treat the sample before the analysis. The morphology of

  18. Part I: A comparative study of bismuth-modified screen-printed electrodes for lead detection

    International Nuclear Information System (INIS)

    Calvo Quintana, Josefina; Arduini, Fabiana; Amine, Aziz; Punzo, Francesco; Destri, Giovanni Li; Bianchini, Chiara; Zane, Daniela; Curulli, Antonella; Palleschi, Giuseppe; Moscone, Danila

    2011-01-01

    Highlights: ► “In situ” Bi-SPE has higher sensitivity than “ex situ” Bi-SPE and “Bi 2 O 3 bulk” SPE. ► Electrochemical treatment of SPE before Bi film deposition allows one to reach low LOD. ► The linearity of Pb 2+ in HCl and HClO 4 is greatly affected by the ionic strength. ► Satisfactory values of the recovery percentage were obtained in drinking water samples. - Abstract: Lead determination was carried out in the frame of the European Union project Biocop ( (www.biocop.org)) using a bismuth-modified screen-printed electrode (Bi-SPE) and the stripping analysis technique. In order to choose a sensitive Bi-SPE for lead detection, an analytical comparative study of electrodes modified by Bi using “in situ”, “ex situ” and “bulk” procedures was carried out. On the basis of the results obtained, we confirmed that the “in situ” procedure resulted in better analytical performances with respect to not only “ex situ” but also to “Bi 2 O 3 bulk” modified electrodes, allowing for a linear range of lead ion concentration from 0.5 to 100 μg L −1 and a detection limit of 0.15 μg L −1 . We demonstrated that, before the Bi film deposition, an oxidative electrochemical pre-treatment of the working electrode could be useful because it eliminates traces of lead in the graphite-ink, as shown with stripping measurements. It also improves the electrochemical performance of the electrodes as demonstrated with Electrochemical Impedance Spectroscopy (EIS) measurements. The influence of different analytical parameters, such as the electrolyte solution composition (acetate buffer, chloridric acid, nitric acid, perchloric acid) and the ionic strength was investigated in order to evaluate how to treat the sample before the analysis. The morphology of prepared “in situ” Bi-SPEs was also characterized by Atomic Force Microscopy (AFM). Finally, the Bi-SPEs were used to determine the concentration of lead ions in tap and commercial water

  19. Theoretical study and experimental detection of cavitation phenomena in Liquid Lithium Target Facility for IFMIF

    International Nuclear Information System (INIS)

    Orco, G. Dell; Horiike, H.; Ida, M.; Nakamura, H.

    2006-01-01

    In the IFMIF (International Fusion Materials Irradiation Facility) testing facility, the required high energy neutrons emission will be produced by reaction of two D + beams with a free surface liquid Lithium jet target flowing along concave back-wall at 20 m/s. The Lithium height in the experimental loop and its relevant static pressure, the high flow velocities and the presence of several devices for the flow control and the pressure reduction increase the risk of cavitation onset in the target system. Special attention has to be taken in the primary pump, in the flow straightener, in the nozzle and their interconnections where the local pressure decreases and/or velocity increases or flow separations could promote the emission of cavitation vapour bubbles. The successive bubble re-implosions, in the higher pressure liquid bulk, could activate material erosion and transportation of activated particulates. These bubbles, if emitted close to the free jet flow, could also procure hydraulic instability and disturbance of the neutron field in the D + beams-Lithium target zone. Therefore, the cavitation risk must be properly foreseen along the whole IFMIF Lithium target circuit and its occurrence at different operating condition should be also monitored by special instrumentation. ENEA, in close cooperation with JAEA, has demonstrated the capability to detect the onset of the cavitation noises in liquid Lithium, by using the ENEA patented accelerometric gauge called CASBA-2000, during hydraulic test campaigns carried-out at Osaka University Lithium facility on a straight mock-up of the IFMIF back plate target. Comparison with the Thoma' cavitation similitude criteria have also determined the critical threshold limit for the estimation of the onset. Theoretical study on the conditions of cavitations generation in the IFMIF Lithium Target Circuit were also launched between ENEA and JAEA aiming at analysing the risk of the cavitation occurrence in the Lithium flow by

  20. Visual attention measures predict pedestrian detection in central field loss: a pilot study.

    Directory of Open Access Journals (Sweden)

    Concetta F Alberti

    Full Text Available The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT and static attention (Useful Field of View; UFOV were predictive of the ability of people with central field loss (CFL to detect pedestrian hazards in simulated driving.11 people with bilateral CFL (visual acuity 20/30-20/200 and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests. Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision.UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse (84% and 97%, respectively; p = 0.001. For CFL participants, higher proportions of timely reactions correlated significantly with higher (better MOT speed thresholds (r = 0.73, p = 0.01, with better performance on the UFOV divided and selective attention subtests (r = -0.66 and -0.62, respectively, p<0.04, with better contrast sensitivity scores (r = 0.54, p = 0.08 and smaller scotomas (r = -0.60, p = 0.05.Our results suggest that brief laboratory-based tests of visual attention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks.

  1. Real time hybridization studies by resonant waveguide gratings using nanopattern imaging for Single Nucleotide Polymorphism detection

    KAUST Repository

    Bougot-Robin, Kristelle; Kodzius, Rimantas; Yue, Weisheng; Chen, Longqing; Li, Shunbo; Zhang, Xixiang; Bé nisty, Henri; Wen, Weijia

    2013-01-01

    2D imaging of biochips is particularly interesting for multiplex biosensing. Resonant properties allow label-free detection using the change of refractive index at the chip surface. We demonstrate a new principle of Scanning Of Resonance on Chip

  2. Plagiarism by Adult Learners Online: A case study in detection and remediation

    Directory of Open Access Journals (Sweden)

    Christine Jocoy

    2006-06-01

    Full Text Available Detecting and combating plagiarism from Web-based sources is a concern for administrators and instructors involved in online distance education. In this paper, we quantify copy-and-paste plagiarism among adult learners in an online geography course offered through Penn State’s World Campus Geographic Information Systems (GIS certificate program. We also evaluate the effectiveness of an “expectation management” strategy intended to discourage adult learners from unintentional violations. We found that while manual methods detected plagiarism in only about 3 percent of assignments, Turnitin.com revealed a 13 percent plagiarism rate among the same assignments. Our attempts to increase awareness and manage expectations decreased infractions measurably, but not significantly. In contrast, Turnitin.com substantially improved our ability to detect infractions. We conclude that raising awareness and managing expectations about plagiarism may be worthwhile, but is no substitute for systematic detection and vigilant enforcement, even among adult learners.

  3. Comparative study of methods of detection of hepatitis ′B′ surface antigen (HBsAg.

    Directory of Open Access Journals (Sweden)

    Parab V

    1989-04-01

    Full Text Available The serum samples were collected from 52 patients of acute viral hepatitis and 235 hospital staff from Kasturba Hospital for Infectious Diseases. HBsAg was detected in their sera by counter-immuno-electrophoresis (CIEP, reverse passive hemogglutination (RPHA and by micro-enzyme-linked-immunosorbent assay (ELISA technique. Among the patients, HBsAg was detected in 12 cases (23% by CIEP, in 18 cases (34% by RPHA and in 23 patients (45% by ELISA. In the hospital staff, HBsAg was detected in 4 samples (1.7% by CIEP, in 8 samples (3.5% by RPHA and in 32 samples (13.5% by ELISA. Thus ELISA was found to be the most sensitive technique in detecting HBsAg.

  4. Detecting COPD exacerbations early using daily telemonitoring of symptoms and k-means clustering: a pilot study.

    Science.gov (United States)

    Sanchez-Morillo, Daniel; Fernandez-Granero, Miguel Angel; Jiménez, Antonio León

    2015-05-01

    COPD places an enormous burden on the healthcare systems and causes diminished health-related quality of life. The highest proportion of human and economic cost is associated with admissions for acute exacerbation of respiratory symptoms (AECOPD). Since prompt detection and treatment of exacerbations may improve outcomes, early detection of AECOPD is a critical issue. This pilot study was aimed to determine whether a mobile health system could enable early detection of AECOPD on a day-to-day basis. A novel electronic questionnaire for the early detection of COPD exacerbations was evaluated during a 6-months field trial in a group of 16 patients. Pattern recognition techniques were applied. A k-means clustering algorithm was trained and validated, and its accuracy in detecting AECOPD was assessed. Sensitivity and specificity were 74.6 and 89.7 %, respectively, and area under the receiver operating characteristic curve was 0.84. 31 out of 33 AECOPD were early identified with an average of 4.5 ± 2.1 days prior to the onset of the exacerbation that was considered the day of medical attendance. Based on the findings of this preliminary pilot study, the proposed electronic questionnaire and the applied methodology could help to early detect COPD exacerbations on a day-to-day basis and therefore could provide support to patients and physicians.

  5. Study on the Application of an Ultra-High-Frequency Fractal Antenna to Partial Discharge Detection in Switchgears

    Directory of Open Access Journals (Sweden)

    Chenguo Yao

    2013-12-01

    Full Text Available The ultra-high-frequency (UHF method is used to analyze the insulation condition of electric equipment by detecting the UHF electromagnetic (EM waves excited by partial discharge (PD. As part of the UHF detection system, the UHF sensor determines the detection system performance in signal extraction and recognition. In this paper, a UHF antenna sensor with the fractal structure for PD detection in switchgears was designed by means of modeling, simulation and optimization. This sensor, with a flat-plate structure, had two resonance frequencies of 583 MHz and 732 MHz. In the laboratory, four kinds of insulation defect models were positioned in the testing switchgear for typical PD tests. The results show that the sensor could reproduce the electromagnetic waves well. Furthermore, to optimize the installation position of the inner sensor for achieving best detection performance, the precise simulation model of switchgear was developed to study the propagation characteristics of UHF signals in switchgear by finite-difference time-domain (FDTD method. According to the results of simulation and verification test, the sensor should be positioned at the right side of bottom plate in the front cabinet. This research established the foundation for the further study on the application of UHF technique in switchgear PD online detection.

  6. Study on Leak Detection of the Pipeline System by Acoustic Emission

    International Nuclear Information System (INIS)

    Yoon, D. J.; Kim, C. J.

    1987-01-01

    Leak detection testing for the pipeline system was performed by the acoustic emission method. It was found that the detected signal spectrum was influenced by the frequency response of sensors and pressure changes. AE parameters and frequency spectrum distributions were used to analyze the leak signals. The slope rise time of AE parameters were the important factors for distinguishing leak signals. The amplitude of leak signal was more affected by the changes of leak, rate and pressure than those of leak type

  7. A study on gold detection in Wenyu gold mine with XRF techniques

    International Nuclear Information System (INIS)

    Liu Liuchun

    1988-01-01

    A portable X ray fluorescence analyzer was used for detecting fluorcescent X rays from the elements associated with gold ores. Fe, As and Ni were chosen to be the indicator elements to analyse rock samples in Wenyu gold mine. Optimum indicators were determined, and it had proved to be successful to detect gold indirectly by measuring the yields of characteristic X rays of the elements. The method provided also valuable information on geology mapping and deposits forming environment

  8. DNA detection in tooth exposed to different temperatures: An in vitro study

    Directory of Open Access Journals (Sweden)

    Rama Raju Devaraju

    2014-01-01

    Full Text Available Introduction: Human identification is an important field of study and research in forensic science and aims at establishing human identity. Several biological materials such as bone, hair, a biopsy sample, saliva and blood have been employed in isolation of DNA for human identification. It is possible to obtain DNA from virtually all human body tissues with variations in the quantity and quality of the DNA extracted from each tissue. Aims and Objectives: A study was carried out in our department to detect the presence of DNA from burnt teeth samples at various temperatures and to highlight the importance of DNA obtained from tooth in identifying a deceased in fire accidents. Materials and Methods: The work included 13 extracted teeth of patients who were indicated for therapeutic extraction and those who were diagnosed clinically and radiographically with caries and periodontitis who were indicated for extraction. Out of the 13 extracted teeth, two were decayed (One had class I dental caries C 1 and the other was grossly decayed C 2 , four were periodontally compromised teeth and the other seven were therapeutically extracted. The freshly extracted teeth were immediately subjected to varying temperatures, from 100°C to 800°C using a Delta burnout furnace for 15-20 minutes. They were cryogenically crushed using a mortar and pestle to make samples of the tooth, which were analysed for DNA. Results: When teeth were incinerated from 100°C-800°C, genomic DNA was obtained only between 100°C and 300°C whereas it was not obtained above this temperature. When the teeth were incinerated from 300°C to 800°C mtDNA was extracted from 300°C to 700°C, but no DNA was obtained above 700°C. Conclusion: Teeth are good sources for DNA, even in cases where the specimens are highly decomposed.

  9. Prospective study of device-related complications in intensive care unit detected by virtual autopsy.

    Science.gov (United States)

    Wichmann, D; Heinemann, A; Zähler, S; Vogel, H; Höpker, W; Püschel, K; Kluge, S

    2018-06-01

    There has been increasing use of invasive techniques, such as extracorporeal organ support, in intensive care units (ICU), and declining autopsy rates. Thus, new measures are needed to maintain high-quality standards. We investigated the potential of computed tomography (CT)-based virtual autopsy to substitute for medical autopsy in this setting. We investigated the potential of virtual autopsy by post-mortem CT to identify complications associated with medical devices in a prospective study of patients who had died in the ICU. Clinical records were reviewed to determine the number and types of medical devices used, and findings from medical and virtual autopsies, related and unrelated to the medical devices, were compared. Medical and virtual autopsies could be performed in 61 patients (Group M/V), and virtual autopsy only in 101 patients (Group V). In Group M/V, 41 device-related complications and 30 device malpositions were identified, but only with a low inter-method agreement. Major findings unrelated to a device were identified in about 25% of patients with a high level of agreement between methods. In Group V, 8 device complications and 36 device malpositions were identified. Device-related complications are frequent in ICU patients. Virtual and medical autopsies showed clear differences in the detection of complications and device malpositions. Both methods should supplement each other rather than one alone for quality control of medical devices in the ICU. Further studies should focus on the identification of special patient populations in which virtual autopsy might be of particular benefit. NCT01541982. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  10. Consumers' experiences and values in conventional and alternative medicine paradigms: a problem detection study (PDS

    Directory of Open Access Journals (Sweden)

    Emmerton Lynne

    2012-04-01

    Full Text Available Abstract Background This study explored consumer perceptions of complementary and alternative medicine (CAM and relationships with CAM and conventional medicine practitioners. A problem detection study (PDS was used. The qualitative component to develop the questionnaire used a CAM consumer focus group to explore conventional and CAM paradigms in healthcare. 32 key issues, seven main themes, informed the questionnaire (the quantitative PDS component - 36 statements explored using five-point Likert scales. Results Of 300 questionnaires distributed (Brisbane, Australia, 83 consumers responded. Results indicated that consumers felt empowered by using CAM and they reported positive relationships with CAM practitioners. The perception was that CAM were used most effectively as long-term therapy (63% agreement, but that conventional medicines would be the best choice for emergency treatment (81% agreement. A majority (65% reported that doctors appeared uncomfortable about consumers' visits to CAM practitioners. Most consumers (72% believed that relationships with and between health practitioners could be enhanced by improved communication. It was agreed that information sharing between consumers and healthcare practitioners is important, and reported that "enough" information is shared between CAM practitioners and consumers. Consumers felt comfortable discussing their medicines with pharmacists, general practitioners and CAM practitioners, but felt most comfortable with their CAM practitioners. Conclusions This PDS has emphasized the perceived importance of open communication between consumers, CAM and conventional providers, and has exposed areas where CAM consumers perceive that issues exist across the CAM and conventional medicine paradigms. There is a lot of information which is perceived as not being shared at present and there are issues of discomfort and distrust which require resolution to develop concordant relationships in healthcare

  11. Detecting early egocentric and allocentric impairments deficits in Alzheimer's disease: an experimental study with virtual reality.

    Science.gov (United States)

    Serino, Silvia; Morganti, Francesca; Di Stefano, Fabio; Riva, Giuseppe

    2015-01-01

    Several studies have pointed out that egocentric and allocentric spatial impairments are one of the earliest manifestations of Alzheimer's Disease (AD). It is less clear how a break in the continuous interaction between these two representations may be a crucial marker to detect patients who are at risk to develop dementia. The main objective of this study is to compare the performances of participants suffering from amnestic mild cognitive impairment (aMCI group), patients with AD (AD group) and a control group (CG), using a virtual reality (VR)-based procedure for assessing the abilities in encoding, storing and syncing different spatial representations. In the first task, participants were required to indicate on a real map the position of the object they had memorized, while in the second task they were invited to retrieve its position from an empty version of the same virtual room, starting from a different position. The entire procedure was repeated across three different trials, depending on the object location in the encoding phase. Our finding showed that aMCI patients performed significantly more poorly in the third trial of the first task, showing a deficit in the ability to encode and store an allocentric viewpoint independent representation. On the other hand, AD patients performed significantly more poorly when compared to the CG in the second task, indicating a specific impairment in storing an allocentric viewpoint independent representation and then syncing it with the allocentric viewpoint dependent representation. Furthermore, data suggested that these impairments are not a product of generalized cognitive decline or of general decay in spatial abilities, but instead may reflect a selective deficit in the spatial organization Overall, these findings provide an initial insight into the cognitive underpinnings of amnestic impairment in aMCI and AD patient exploiting the potentiality of VR.

  12. Predictive error detection in pianists: A combined ERP and motion capture study

    Directory of Open Access Journals (Sweden)

    Clemens eMaidhof

    2013-09-01

    Full Text Available Performing a piece of music involves the interplay of several cognitive and motor processes and requires extensive training to achieve a high skill level. However, even professional musicians commit errors occasionally. Previous event-related potential (ERP studies have investigated the neurophysiological correlates of pitch errors during piano performance, and reported pre-error negativity already occurring approximately 70-100 ms before the error had been committed and audible. It was assumed that this pre-error negativity reflects predictive control processes that compare predicted consequences with actual consequences of one’s own actions. However, in previous investigations, correct and incorrect pitch events were confounded by their different tempi. In addition, no data about the underlying movements were available. In the present study, we exploratively recorded the ERPs and 3D movement data of pianists’ fingers simultaneously while they performed fingering exercises from memory. Results showed a pre-error negativity for incorrect keystrokes when both correct and incorrect keystrokes were performed with comparable tempi. Interestingly, even correct notes immediately preceding erroneous keystrokes elicited a very similar negativity. In addition, we explored the possibility of computing ERPs time-locked to a kinematic landmark in the finger motion trajectories defined by when a finger makes initial contact with the key surface, that is, at the onset of tactile feedback. Results suggest that incorrect notes elicited a small difference after the onset of tactile feedback, whereas correct notes preceding incorrect ones elicited negativity before the onset of tactile feedback. The results tentatively suggest that tactile feedback plays an important role in error-monitoring during piano performance, because the comparison between predicted and actual sensory (tactile feedback may provide the information necessary for the detection of an

  13. Wireless sensing without sensors—an experimental study of motion/intrusion detection using RF irregularity

    International Nuclear Information System (INIS)

    Lee, Pius W Q; Tan, Hwee-Pink; Seah, Winston K G; Yao, Zexi

    2010-01-01

    Motion and intrusion detection are often cited as wireless sensor network (WSN) applications with typical configurations comprising clusters of wireless nodes equipped with motion sensors to detect human motion. Currently, WSN performance is subjected to several constraints, namely radio irregularity and finite on-board computation/energy resources. Radio irregularity in radio frequency (RF) propagation rises to a higher level in the presence of human activity due to the absorption effect of the human body. In this paper, we investigate the feasibility of monitoring RF transmission for the purpose of intrusion detection through experimentation. With empirical data obtained from the Crossbow TelosB platform in several different environments, the impact of human activity on the signal strength of RF signals in a WSN is evaluated. We then propose a novel approach to intrusion detection by turning a constraint in WSN, namely radio irregularity, into an advantage for the purpose of intrusion detection, using signal fluctuations to detect the presence of human activity within the WSN. Unlike RF fingerprinting, the 'intruders' here neither transmit nor receive any RF signals. By enabling existing wireless infrastructures to serve as intrusion detectors instead of deploying numerous costly sensors, this approach shows great promise for providing novel solutions

  14. Relationship of external fish condition to pathogen prevalence and out-migration survival in juvenile steelhead

    Science.gov (United States)

    Hostetter, N.J.; Evans, A.F.; Roby, D.D.; Collis, K.; Hawbecker, M.; Sandford, B.P.; Thompson, D.E.; Loge, F.J.

    2011-01-01

    Understanding how the external condition of juvenile salmonids is associated with internal measures of health and subsequent out-migration survival can be valuable for population monitoring programs. This study investigated the use of a rapid, nonlethal, external examination to assess the condition of run-of-the-river juvenile steelhead Oncorhynchus mykiss migrating from the Snake River to the Pacific Ocean. We compared the external condition (e.g., body injuries, descaling, external signs of disease, fin damage, and ectoparasite infestations) with (1) the internal condition of a steelhead as measured by the presence of selected pathogens detected by histopathology and polymerase chain reaction analysis and (2) out-migration survival through the Snake and Columbia rivers as determined by passive integrated transponder (PIT) tag technology. The results from steelhead captured and euthanized (n = 222) at Lower Monumental Dam on the lower Snake River in 2008 indicated that external condition was significantly correlated with selected measures of internal condition. The odds of testing positive for a pathogen were 39.2, 24.3, and 5.6 times greater for steelhead with severe or moderate external signs of disease or more than 20% descaling, respectively. Capture-recapture models of 22,451 PIT-tagged steelhead released at Lower Monumental Dam in 2007-2009 indicated that external condition was significantly correlated with juvenile survival. The odds of outmigration survival for steelhead with moderate or severe external signs of disease, more than 20% descaling, or severe fin damage were 5.7, 4.9, 1.6, and 1.3 times lower, respectively, than those for steelhead without these external conditions. This study effectively demonstrated that specific measures of external condition were associated with both the internal condition and out-migration survival of juvenile steelhead. ?? American Fisheries Society 2011.

  15. A Feasibility Study on the Automatic Detection of Atrial Fibrillations using an Unobtrusive Bed-Mounted Sensor

    NARCIS (Netherlands)

    Brueser, C.; Zink, M.D.H.; Winter, S.; Schauerte, P.; Leonhardt, S.

    2012-01-01

    We present a feasibility study on the automatic detection of atrialfibrillations (AF) from a cardiac vibration signal (ballistocardiogram). Signals were recorded by means of an electromechanical foil attached to a bed’s mattress. A clinical study with 10 AF patients wasconducted to assess whether

  16. Identification of Swallowing Tasks from a Modified Barium Swallow Study That Optimize the Detection of Physiological Impairment

    Science.gov (United States)

    Hazelwood, R. Jordan; Armeson, Kent E.; Hill, Elizabeth G.; Bonilha, Heather Shaw; Martin-Harris, Bonnie

    2017-01-01

    Purpose: The purpose of this study was to identify which swallowing task(s) yielded the worst performance during a standardized modified barium swallow study (MBSS) in order to optimize the detection of swallowing impairment. Method: This secondary data analysis of adult MBSSs estimated the probability of each swallowing task yielding the derived…

  17. Study of electromagnetic noise influence on quench detection system under different discharge conditions for EAST

    International Nuclear Information System (INIS)

    Hu, Yanlan; Li, Jiangang; Shen, Biao; Lv, Huanyu; Xiao, Y.Z.

    2013-01-01

    Highlights: ► Reliable quench detection in EAST is a key issue for steady-state operation. ► The electromagnet noise interference associated with detection signals under different discharge conditions are evaluated. ► The effective measures have been realized on detection systems. ► Recently upgrade work has been done, especially for the optimization of ACS and false FSDS were reduced greatly. -- Abstract: EAST is the first Tokamak device whose toroidal and poloidal magnet are superconducting. The enormous magnetic field energy stored in the magnet system will transfer into thermal energy and cause the damage of superconducting magnet, if a quench happened. Therefore, reliable quench detection is a key issue for steady-state operation. In addition to electromagnetic noise from poloidal magnet fields and plasma current which will experience fast current ramp rate, radio frequency noise from heating system also have some interference on quench detection system to a certain degree. The most difficult point for quench detection system is required to have more detail evaluation on electromagnetic noise interference. Recently experiments have been carried out successfully in EAST device. The steady-state operation with 1 MA of plasma current and more than 100-s plasma duration has been obtained. In the paper, the electromagnetic noise interference on quench detection system under different discharge conditions are analyzed and relative process methods are also introduced. The technological experience and experimental data are significant for the constructing ITER and similar superconducting device have been mentioned which will supply significant technological experience and experimental data for constructing ITER and similar superconducting device

  18. Making great leaps forward: Accounting for detectability in herpetological field studies

    Science.gov (United States)

    Mazerolle, Marc J.; Bailey, Larissa L.; Kendall, William L.; Royle, J. Andrew; Converse, Sarah J.; Nichols, James D.

    2007-01-01

    Detecting individuals of amphibian and reptile species can be a daunting task. Detection can be hindered by various factors such as cryptic behavior, color patterns, or observer experience. These factors complicate the estimation of state variables of interest (e.g., abundance, occupancy, species richness) as well as the vital rates that induce changes in these state variables (e.g., survival probabilities for abundance; extinction probabilities for occupancy). Although ad hoc methods (e.g., counts uncorrected for detection, return rates) typically perform poorly in the face of no detection, they continue to be used extensively in various fields, including herpetology. However, formal approaches that estimate and account for the probability of detection, such as capture-mark-recapture (CMR) methods and distance sampling, are available. In this paper, we present classical approaches and recent advances in methods accounting for detectability that are particularly pertinent for herpetological data sets. Through examples, we illustrate the use of several methods, discuss their performance compared to that of ad hoc methods, and we suggest available software to perform these analyses. The methods we discuss control for imperfect detection and reduce bias in estimates of demographic parameters such as population size, survival, or, at other levels of biological organization, species occurrence. Among these methods, recently developed approaches that no longer require marked or resighted individuals should be particularly of interest to field herpetologists. We hope that our effort will encourage practitioners to implement some of the estimation methods presented herein instead of relying on ad hoc methods that make more limiting assumptions.

  19. Effects of platooning on signal-detection performance, workload, and stress: A driving simulator study.

    Science.gov (United States)

    Heikoop, Daniël D; de Winter, Joost C F; van Arem, Bart; Stanton, Neville A

    2017-04-01

    Platooning, whereby automated vehicles travel closely together in a group, is attractive in terms of safety and efficiency. However, concerns exist about the psychological state of the platooning driver, who is exempted from direct control, yet remains responsible for monitoring the outside environment to detect potential threats. By means of a driving simulator experiment, we investigated the effects on recorded and self-reported measures of workload and stress for three task-instruction conditions: (1) No Task, in which participants had to monitor the road, (2) Voluntary Task, in which participants could do whatever they wanted, and (3) Detection Task, in which participants had to detect red cars. Twenty-two participants performed three 40-min runs in a constant-speed platoon, one condition per run in counterbalanced order. Contrary to some classic literature suggesting that humans are poor monitors, in the Detection Task condition participants attained a high mean detection rate (94.7%) and a low mean false alarm rate (0.8%). Results of the Dundee Stress State Questionnaire indicated that automated platooning was less distressing in the Voluntary Task than in the Detection Task and No Task conditions. In terms of heart rate variability, the Voluntary Task condition yielded a lower power in the low-frequency range relative to the high-frequency range (LF/HF ratio) than the Detection Task condition. Moreover, a strong time-on-task effect was found, whereby the mean heart rate dropped from the first to the third run. In conclusion, participants are able to remain attentive for a prolonged platooning drive, and the type of monitoring task has effects on the driver's psychological state. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Prevalence of abnormalities in knees detected by MRI in adults without knee osteoarthritis: population based observational study (Framingham Osteoarthritis Study).

    Science.gov (United States)

    Guermazi, Ali; Niu, Jingbo; Hayashi, Daichi; Roemer, Frank W; Englund, Martin; Neogi, Tuhina; Aliabadi, Piran; McLennan, Christine E; Felson, David T

    2012-08-29

    To examine use of magnetic resonance imaging (MRI) of knees with no radiographic evidence of osteoarthritis to determine the prevalence of structural lesions associated with osteoarthritis and their relation to age, sex, and obesity. Population based observational study. Community cohort in Framingham, MA, United States (Framingham osteoarthritis study). 710 people aged >50 who had no radiographic evidence of knee osteoarthritis (Kellgren-Lawrence grade 0) and who underwent MRI of the knee. Prevalence of MRI findings that are suggestive of knee osteoarthritis (osteophytes, cartilage damage, bone marrow lesions, subchondral cysts, meniscal lesions, synovitis, attrition, and ligamentous lesions) in all participants and after stratification by age, sex, body mass index (BMI), and the presence or absence of knee pain. Pain was assessed by three different questions and also by WOMAC questionnaire. Of the 710 participants, 393 (55%) were women, 660 (93%) were white, and 206 (29%) had knee pain in the past month. The mean age was 62.3 years and mean BMI was 27.9. Prevalence of "any abnormality" was 89% (631/710) overall. Osteophytes were the most common abnormality among all participants (74%, 524/710), followed by cartilage damage (69%, 492/710) and bone marrow lesions (52%, 371/710). The higher the age, the higher the prevalence of all types of abnormalities detectable by MRI. There were no significant differences in the prevalence of any of the features between BMI groups. The prevalence of at least one type of pathology ("any abnormality") was high in both painful (90-97%, depending on pain definition) and painless (86-88%) knees. MRI shows lesions in the tibiofemoral joint in most middle aged and elderly people in whom knee radiographs do not show any features of osteoarthritis, regardless of pain.

  1. Recruitment in a Colorado population of big brown bats: Breeding probabilities, litter size, and first-year survival

    Science.gov (United States)

    O'Shea, T.J.; Ellison, L.E.; Neubaum, D.J.; Neubaum, M.A.; Reynolds, C.A.; Bowen, R.A.

    2010-01-01

    We used markrecapture estimation techniques and radiography to test hypotheses about 3 important aspects of recruitment in big brown bats (Eptesicus fuscus) in Fort Collins, Colorado: adult breeding probabilities, litter size, and 1st-year survival of young. We marked 2,968 females with passive integrated transponder (PIT) tags at multiple sites during 2001-2005 and based our assessments on direct recaptures (breeding probabilities) and passive detection with automated PIT tag readers (1st-year survival). We interpreted our data in relation to hypotheses regarding demographic influences of bat age, roost, and effects of years with unusual environmental conditions: extreme drought (2002) and arrival of a West Nile virus epizootic (2003). Conditional breeding probabilities at 6 roosts sampled in 2002-2005 were estimated as 0.64 (95% confidence interval [95% CI] = 0.530.73) in 1-year-old females, but were consistently high (95% CI = 0.940.96) and did not vary by roost, year, or prior year breeding status in older adults. Mean litter size was 1.11 (95% CI = 1.051.17), based on examination of 112 pregnant females by radiography. Litter size was not higher in older or larger females and was similar to results of other studies in western North America despite wide variation in latitude. First-year survival was estimated as 0.67 (95% CI = 0.610.73) for weaned females at 5 maternity roosts over 5 consecutive years, was lower than adult survival (0.79; 95% CI = 0.770.81), and varied by roost. Based on model selection criteria, strong evidence exists for complex roost and year effects on 1st-year survival. First-year survival was lowest in bats born during the drought year. Juvenile females that did not return to roosts as 1-year-olds had lower body condition indices in late summer of their natal year than those known to survive. ?? 2009 American Society of Mammalogists.

  2. Prevalence of diabetic retinopathy in screening-detected diabetes mellitus: results from the Gutenberg Health Study (GHS).

    Science.gov (United States)

    Ponto, Katharina A; Koenig, Jochem; Peto, Tunde; Lamparter, Julia; Raum, Philipp; Wild, Philipp S; Lackner, Karl J; Pfeiffer, Norbert; Mirshahi, Alireza

    2016-09-01

    Individuals with type 2 diabetes mellitus may experience an asymptomatic period of hyperglycaemia, and complications may already be present at the time of diagnosis. We aimed to determine the prevalence of diabetic retinopathy in patients with newly diagnosed (screening-detected) type 2 diabetes. The Gutenberg Health Study is a population-based study with 15,010 participants aged between 35 and 74 years. We determined the weighted prevalence of diabetic retinopathy by assessing fundus photographs. Screening-detected type 2 diabetes was defined as an HbA1c concentration of 6.5% (47.5 mmol/mol) or more, no medical diagnosis of diabetes and no intake of insulin or oral glucose-lowering agents. Of 14,948 participants, 1377 (9.2%) had diabetes mellitus. Of these, 347 (25.2%) had newly diagnosed type 2 diabetes detected by the screening. Overall, the weighted prevalence of screening-detected type 2 diabetes was 2.1%. Fundus photos were evaluable for 285 (82.1%) participants with newly diagnosed diabetes. The weighted prevalence of diabetic retinopathy in screening-detected type 2 diabetes was 13.0%; 12% of participants had a mild non-proliferative diabetic retinopathy and 0.6% had a moderate non-proliferative diabetic retinopathy. Diabetic retinopathy was proliferative in 0.3%. No cases of severe non-proliferative diabetic retinopathy or diabetic maculopathy were found. Thirty (14.9%) of 202 and six (7.2%) of 83 individuals with and without concomitant arterial hypertension, respectively, had diabetic retinopathy (OR 2.54, 95% CI 1.06, 7.14). Visual acuity did not differ between individuals with and without diabetic retinopathy . In this large European study, the prevalence of diabetic retinopathy in screening-detected type 2 diabetes was 13%. Only a very small proportion of participants with detected diabetic retinopathy needed treatment.

  3. Improvements in balance control in individuals with PCS detected following vestibular training: A case study.

    Science.gov (United States)

    Prangley, Alyssa; Aggerholm, Mathew; Cinelli, Michael

    2017-10-01

    Concussed individuals have been found to experience balance deficits in the anterior-posterior (AP) direction as indicated by greater Center of Pressure (COP) displacement and velocity. One possible reason for this change in balance control could be due to damage to the lateral vestibulospinal tract which sends signals to control posterior muscles, specifically ankle extensors leading to compensatory torques about the ankle. The purpose of the study was to quantify balance assessments in individuals experiencing persistent post-concussion symptoms (PCS) to determine balance control changes following a vestibular training intervention. Participants (N=6,>26days symptomatic), were tested during their first appointment with a registered physiotherapist (PT) and during each follow up appointment. Participants were prescribed balance, visual, and neck strengthening exercises by the PT that were to be completed daily between bi-weekly appointments. Balance assessments were quantified using a Nintendo Wii board to record ground reaction forces. Participants completed 4 balance assessments: 1) Romberg stance eyes open (REO); 2) Romberg stance eyes closed (REC); 3) single leg stance eyes open (SEO); and 4) single leg stance eyes closed (SEC). The balance assessments were conducted on both a firm and compliant surfaces. Significant improvements in balance control were noted in ML/AP displacement and velocity of COP for both SEC and Foam REC conditions, with additional improvements in AP velocity of COP for Foam REC and in ML displacement of COP during Foam SEC. Overall, findings indicate that objectively quantifying balance changes for individuals experiencing persistent PCS allows for a more sensitive measure of balance and detects changes unrecognizable to the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The study on the factors for detection of renal stone on ultrasound

    International Nuclear Information System (INIS)

    Sim, Hyun Sun; Jung, Hong Ryang; Lim, Cheong Hwan

    2006-01-01

    Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. The stone was place on sponge examined in a water bath with a 3.5 MHz or 7.5 HMz transducer (LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. 1) Average echo level was 98 for low total gain (10 dB) and was 142 for high total gain (40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range (42 dB) and was 101 for high dynamic range (72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency (7.5 MHz) than low frequency (3.5 MHz) and it is not distorted. The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis

  5. High-throughput screening of saliva for early detection of oral cancer: a pilot study.

    Science.gov (United States)

    Szanto, I; Mark, L; Bona, A; Maasz, G; Sandor, B; Gelencser, G; Turi, Z; Gallyas, F

    2012-04-01

    The success of tumour therapy depends considerably on early diagnosis. Therefore, we aimed to develop a widely available, cheap, non-invasive, high-throughput method suitable for screening high-risk populations, at least, for early signs of malignant transformation in the oral cavity. First, in order to identify suitable tumour marker candidates, we compared the protein patterns of five selected saliva samples obtained from healthy controls and tumour patients after electrophoretic separation, excised the bands that were consistently up-r