  1. Simulation of Electron Behavior in PIG Ion Source for 9MeV Cyclotron

    CERN Document Server

    Ghergherehchi, Mitra; Yeon, Yeong- Heum; Chai, Jong- Seo

    2013-01-01

    In this paper, we focus on a PIG source for producing intense H-ions inside a 9MeV cyclotron. The properties of the PIG ion source were simulated for a variety of electric field distributions and magnetic field strengths using CST Particle Studio. After analyzing secondary electron emission (SEE) as a function of both magnetic and electric field strengths, we found that for the modeled PIG geometry a magnetic field strength of 0.2 T provided the best results in term of number of secondary electrons. Furthermore, at 0.2 T the number of secondary electrons proved to be greatest regardless of the cathode potential. Also the modified PIG ion source with quartz insulation tubes was tested in KIRAMS-13 cyclotron by varying gas flow rate and arc current, respectively. The capacity of the designed ion source was also demonstrated by producing plasma inside the constructed 9MeV cyclotron. As a result, the ion source is verified to be capable to produce intense H- beam and high ion beam current for the desired 9 MeV cy...

  2. Effect of resonant microwave power on a PIG ion source. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Brown, I.G.; Galvin, J.E.; Gavin, B.F.; MacGill, R.A.

    1984-08-01

    We have investigated the effect of applying microwave power at the electron cyclotron frequency on the characteristics of the ion beam extracted from a hot-cathode PIG ion source. No change was seen in the ion charge state distribution. A small but significant reduction in the beam noise level was seen, and it is possible that the technique may find application in situations where beam quiescence is important. 32 refs., 2 figs.

  3. Effect of resonant microwave power on a PIG ion source. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Brown, I.G.; Galvin, J.E.; Gavin, B.F.; MacGill, R.A.

    1984-08-01

    We have investigated the effect of applying microwave power at the electron cyclotron frequency on the characteristics of the ion beam extracted from a hot-cathode PIG ion source. No change was seen in the ion charge state distribution. A small but significant reduction in the beam noise level was seen, and it is possible that the technique may find application in situations where beam quiescence is important. 32 refs., 2 figs.

  4. A preliminary study of a negative hydrogen PIG-type ion source for the compact cyclotron

    Institute of Scientific and Technical Information of China (English)

    YANG Zhen; LONG Ji-Dong; DONG Pan; WANG Tao; WEI Tao; HE Xiao-Zhong; ZHANG Kai-Zhi; SHI Jin-Shui

    2012-01-01

    A Penning ion gauge (PIG)-type ion source has been used for the generation of negative hydrogen ions (H-) as the internal ion source of the compact cyclotron.The discharge characteristics of the ion source are systematically studied for hydrogen operation at different discharge currents and gas flow rates on the prototype cyclotron.The preliminary study results for the low DC voltage H- extraction measurements are presented in this paper.The H- beam current is measured by the order of magnitude from several tens to hundreds of microamperes at different parameter conditions.The discussion and analysis for the experimental results are good for improving the design and working stability of the ion source.

  5. Using the Orbit Tracking Code Z3CYCLONE to Predict the Beam Produced by a Cold Cathode PIG Ion Source for Cyclotrons under DC Extraction

    CERN Document Server

    Forringer, Edward

    2005-01-01

    Experimental measurements of the emittance and luminosity of beams produced by a cold-cathode Phillips Ionization Guage (PIG) ion source for cyclotrons under dc extraction are reviewed. (The source being studied is of the same style as ones that will be used in a series of 250 MeV proton cyclotrons being constructed for cancer therapy by ACCEL Inst, Gmbh, of Bergisch Gladbach, Germany.) The concepts of 'plasma boundary' and 'plasma temperature' are presented as a useful set of parameters for describing the initial conditions used in computational orbit tracking. Experimental results for r-pr and z-pz emittance are compared to predictions from the MSU orbit tracking code Z3CYCLONE with results indicating that the code is able to predict the beam produced by these ion sources with adequate accuracy such that construction of actual cyclotrons can proceed with reasonably prudent confidence that the cyclotron will perform as predicted.

  6. Electron Beam Ion Sources

    OpenAIRE

    Zschornacka, G.; Schmidt, M.; Thorn, A.

    2014-01-01

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviole...

  7. Multicusp ion sources (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N. (Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (United States))

    1994-04-01

    During the last decade, different types of multicusp ion sources, such as high current, high concentration H[sup +], H[sup +][sub 2], or N[sup +] ion sources, negative ion sources, radio-frequency-driven sources, and high charge state ion sources have been developed at the Lawrence Berkeley Laboratory. This article reviews the history of the research and development of these ion sources and their applications.

  8. Ion Source DECRIS-3

    CERN Document Server

    Efremov, A; Lebedev, A N; Loginov, V N; Yazvitsky, N Yu

    1999-01-01

    The ECR ion source DECRIS-3 is the copy of the mVINIS ion source which was designed and built in Dubna for the TESLA Accelerator Installation (Belgrade, Yugoslavia) in 1997. The assembly of the source was completely finished in the end of 1998 and then it was installed at the FLNR ECR test bench. The source was successfully tested with some gases and metals by using the MIVOC technique. In nearest future the source will be capable of ECR plasma heating using two different frequencies simultaneously. We are also going to use the DECRIS-3 ion source to design 1+ -> n+ technique for the DRIBs (Dubna Radioactive Ion Beams) project.

  9. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  10. Peristaltic ion source

    Energy Technology Data Exchange (ETDEWEB)

    Brown, I.G.; Anders, A.; Anders, S.; Dickinson, M.R.; MacGill, R.A.

    1995-08-01

    Conventional ion sources generate energetic ion beams by accelerating the plasma-produced ions through a voltage drop at the extractor, and since it is usual that the ion beam is to propagate in a space which is at ground potential, the plasma source is biased at extractor voltage. For high ion beam energy the plasma source and electrical systems need to be raised to high voltage, a task that adds considerable complexity and expense to the total ion source system. The authors have developed a system which though forming energetic ion beams at ground potential as usual, operates with the plasma source and electronics at ground potential also. Plasma produced by a nearby source streams into a grided chamber that is repetitively pulsed from ground to high positive potential, sequentially accepting plasma into its interior region and ejecting it energetically. They call the device a peristaltic ion source. In preliminary tests they`ve produced nitrogen and titanium ion beams at energies from 1 to 40 keV. Here they describe the philosophy behind the approach, the test embodiment that they have made, and some preliminary results.

  11. Radio frequency ion source

    CERN Document Server

    Shen Guan Ren; Gao Fu; LiuNaiYi

    2001-01-01

    The study on Radio Frequency Ion Source is mainly introduced, which is used for CIAE 600kV ns Pulse Neutron Generator; and obtained result is also presented. The RF ion source consists of a diameter phi 25 mm, length 200 mm, coefficient of expansion =3.5 mA, beam current on target >=1.5 mA, beam spot =100 h.

  12. Lithium ion sources

    Science.gov (United States)

    Roy, Prabir K.; Greenway, Wayne G.; Grote, Dave P.; Kwan, Joe W.; Lidia, Steven M.; Seidl, Peter A.; Waldron, William L.

    2014-01-01

    A 10.9 cm diameter lithium alumino-silicate ion source has been chosen as a source of ˜100mA lithium ion current for the Neutralized Drift Compression Experiment (NDCX-II) at LBNL. Research and development was carried out on lithium alumino-silicate ion sources prior to NDCX-II source fabrication. Space-charge-limited emission with the current density exceeding 1 mA/cm2 was measured with 0.64 cm diameter lithium alumino-silicate ion sources at 1275 °C. The beam current density is less for the first 10.9 cm diameter NDCX-II source, and it may be due to an issue of surface coverage. The lifetime of a thin coated (on a tungsten substrate) source is varied, roughly 40-50 h, when pulsed at 0.05 Hz and with pulse length of 6μs each, i.e., a duty factor of 3×10-7, at an operating temperature of 1250-1275 °C. The 10.9 cm diameter source lifetime is likely the same as of a 0.64 cm source, but the lifetime of a source with a 2 mm diameter (without a tungsten substrate) is 10-15 h with a duty factor of 1 (DC extraction). The lifetime variation is dependent on the amount of deposition of β-eucryptite mass, and the surface temperature. The amount of mass deposition does not significantly alter the current density. More ion source work is needed to improve the large source performance.

  13. Lithium ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Prabir K., E-mail: pkroy@lbl.gov [Lawrence Berkeley National Laboratory (LBNL), One Cyclotron Road, Berkeley, California CA-94720 (United States); Greenway, Wayne G. [Lawrence Berkeley National Laboratory (LBNL), One Cyclotron Road, Berkeley, California CA-94720 (United States); Grote, Dave P. [Lawrence Livermore National Laboratory LLC, CA-94550 (United States); Kwan, Joe W.; Lidia, Steven M.; Seidl, Peter A.; Waldron, William L. [Lawrence Berkeley National Laboratory (LBNL), One Cyclotron Road, Berkeley, California CA-94720 (United States)

    2014-01-01

    A 10.9 cm diameter lithium alumino-silicate ion source has been chosen as a source of ∼100mA lithium ion current for the Neutralized Drift Compression Experiment (NDCX-II) at LBNL. Research and development was carried out on lithium alumino-silicate ion sources prior to NDCX-II source fabrication. Space-charge-limited emission with the current density exceeding 1 mA/cm{sup 2} was measured with 0.64 cm diameter lithium alumino-silicate ion sources at 1275 °C. The beam current density is less for the first 10.9 cm diameter NDCX-II source, and it may be due to an issue of surface coverage. The lifetime of a thin coated (on a tungsten substrate) source is varied, roughly 40–50 h, when pulsed at 0.05 Hz and with pulse length of 6μs each, i.e., a duty factor of 3×10{sup −7}, at an operating temperature of 1250–1275 °C. The 10.9 cm diameter source lifetime is likely the same as of a 0.64 cm source, but the lifetime of a source with a 2 mm diameter (without a tungsten substrate) is 10–15 h with a duty factor of 1 (DC extraction). The lifetime variation is dependent on the amount of deposition of β-eucryptite mass, and the surface temperature. The amount of mass deposition does not significantly alter the current density. More ion source work is needed to improve the large source performance.

  14. Microwave Discharge Ion Sources

    CERN Document Server

    Celona, L

    2013-01-01

    This chapter describes the basic principles, design features and characteristics of microwave discharge ion sources. A suitable source for the production of intense beams for high-power accelerators must satisfy the requirements of high brightness, stability and reliability. The 2.45 GHz off-resonance microwave discharge sources are ideal devices to generate the required beams, as they produce multimilliampere beams of protons, deuterons and singly charged ions. A description of different technical designs will be given, analysing their performance, with particular attention being paid to the quality of the beam, especially in terms of its emittance.

  15. A negative ion source for alkali ions

    NARCIS (Netherlands)

    Vermeer, A.; Zwol, N.A. van

    1980-01-01

    An ion source is described which delivers negative alkali ions. With this source, which consists of a duoplasmatron and a charge exchange canal with alkali vapour, negative Li, Na and K ions are produced. The oven in which alkali metals are evaporated can reach temperatures up to 575°C.

  16. A negative ion source for alkali ions

    NARCIS (Netherlands)

    Vermeer, A.; Zwol, N.A. van

    1980-01-01

    An ion source is described which delivers negative alkali ions. With this source, which consists of a duoplasmatron and a charge exchange canal with alkali vapour, negative Li, Na and K ions are produced. The oven in which alkali metals are evaporated can reach temperatures up to 575°C.

  17. Novel laser ion sources

    CERN Document Server

    Fournier, P; Kugler, H; Lisi, N; Scrivens, R; Rodríguez, F V; Düsterer, S; Sauerbrey, R; Schillinger, H; Theobald, W; Veisz, L; Tisch, J W G; Smith, R A

    2000-01-01

    Development in the field of high-power laser systems with repetition rates of several Hz and energies of few joules is highly active and opening, giving new possibilities for the design of laser ions sources. Preliminary investigations on the use of four different laser and target configurations are presented: (1) A small CO/sub 2/ laser (100 mJ, 10.6 mu m) focused onto a polyethylene target to produce C ions at 1 Hz repetition rate (CERN). (2) An excimer XeCl laser (6 J, 308 nm) focused onto solid targets (Frascati). (3) A femtosecond Ti: sapphire laser (250 mJ, 800 nm) directed onto a solid targets (Jena). (4) A picosecond Nd: yttrium-aluminum-garnet (0.3 J, 532 nm) focused into a dense medium of atomic clusters and onto solid targets (London). The preliminary experimental results and the most promising schemes will be discussed with respect to the scaling of the production of high numbers of highly charged ions. Different lasers are compared in terms of current density at 1 m distance for each charge state...

  18. Ion sources for ion implantation technology (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Shigeki, E-mail: sakai-shigeki@nissin.co.jp; Hamamoto, Nariaki; Inouchi, Yutaka; Umisedo, Sei; Miyamoto, Naoki [Nissin Ion Equipment co., ltd, 575 Kuze-Tonoshiro-cho Minami-ku, Kyoto 601-8205 (Japan)

    2014-02-15

    Ion sources for ion implantation are introduced. The technique is applied not only to large scale integration (LSI) devices but also to flat panel display. For LSI fabrication, ion source scheduled maintenance cycle is most important. For CMOS image sensor devices, metal contamination at implanted wafer is most important. On the other hand, to fabricate miniaturized devices, cluster ion implantation has been proposed to make shallow PN junction. While for power devices such as silicon carbide, aluminum ion is required. For doping processes of LCD fabrication, a large ion source is required. The extraction area is about 150 cm × 10 cm, and the beam uniformity is important as well as the total target beam current.

  19. Ion sources for cyclotron applications

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; Bachman, D.A.; McDonald, D.S.; Young, A.T.

    1992-07-01

    The use of a multicusp plasma generator as an ion source has many advantages. The development of both positive and negative ion beams based on the multicusp source geometry is presented. It is shown that these sources can be operated at steady state or cw mode. As a result they are very suitable for cyclotron operations.

  20. Operation of ECR Ion Source

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In 2001, ECR ion source was operated for HIRFL about 5138 hours and 8 species of ion beams, such as ~(12)C~(4+), ~(12)C~(5+), ~(36)Ar~(11+),~(13)C~(4+),~(40)Ca~(11+),~(40)Ar~(11+),~(56)Fe~(10+) and ~(18)O~(6+) were provided. Among these ions,~(56)Fe~(10+)is a new ion beam. In this period, 14 experiments of heavy ion physics application and nuclear research were finished.

  1. Ion sources for heavy ion fusion (invited)

    Science.gov (United States)

    Yu, Simon S.; Eylon, S.; Chupp, W.; Henestroza, E.; Lidia, S.; Peters, C.; Reginato, L.; Tauschwitz, A.; Grote, D.; Deadrick, F.

    1996-03-01

    The development of ion sources for heavy ion fusion will be reported with particular emphasis on a recently built 2 MV injector. The new injector is based on an electrostatic quadrupole configuration, and has produced pulsed K+ ions of 950 mA peak from a 6.7 in. curved alumino silicate source. The ion beam has reached 2.3 MV with an energy flatness of ±0.2% over 1 μs. The measured normalized edge emittance of less than 1 π mm mrad is close to the source temperature limit. The design, construction, performance, and comparisons with three-dimensional particle-in-cell simulations will be described.

  2. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source.

    Science.gov (United States)

    Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W

    2012-06-01

    The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

  3. Hooded arc ion-source

    CERN Multimedia

    1972-01-01

    The positioning system for the hooded arc ion-source, shown prior to mounting, consists of four excentric shafts to locate the ion-source and central electrodes. It will be placed on the axis of the SC and introduced into the vacuum tank via the air locks visible in the foreground.

  4. Gas and metal ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Oaks, E. [High Current Electronics Institute, Tomsk (Russian Federation)]|[State Academy of Control System and Radioelectronics, Tomsk (Russian Federation); Yushkov, G. [High Current Electronics Institute, Tomsk (Russian Federation)

    1996-08-01

    The positive ion sources are now of interest owing to both their conventional use, e.g., as injectors in charged-particle accelerators and the promising capabilities of intense ion beams in the processes related to the action of ions on various solid surfaces. For industrial use, the sources of intense ion beams and their power supplies should meet the specific requirements as follows: They should be simple, technologically effective, reliable, and relatively low-cost. Since the scanning of an intense ion beam is a complicated problem, broad ion beams hold the greatest promise. For the best use of such beams it is desirable that the ion current density be uniformly distributed over the beam cross section. The ion beam current density should be high enough for the treatment process be accomplished for an acceptable time. Thus, the ion sources used for high-current, high-dose metallurgical implantation should provide for gaining an exposure dose of {approximately} 10{sup 17} cm{sup {minus}2} in some tens of minutes. So the average ion current density at the surface under treatment should be over 10{sup {minus}5} A/cm{sup 2}. The upper limit of the current density depends on the admissible heating of the surface under treatment. The accelerating voltage of an ion source is dictated by its specific use; it seems to lie in the range from {approximately}1 kV (for the ion source used for surface sputtering) to {approximately}100 kV and over (for the ion sources used for high-current, high-dose metallurgical implantation).

  5. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  6. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  7. Alternative fat sources to animal fat for pigs

    DEFF Research Database (Denmark)

    Lauridsen, Charlotte; Christensen, Thomas Bruun; Halekoh, Ulrich

    2007-01-01

    The use of fats and oils in diets for pigs is of great importance due to their high energy value. As a consequence of the BSE-crisis in the European Union, the amount of animal fat available for animal feeds has been reduced, and alternative fat sources are of increasing importance. In this paper......% of either animal fat, palm oil mix, palm oil, vegetable oil mix, coconut oil, or rapeseed oil were tested in weaned and growing pigs. It was concluded that several vegetable fat sources (palm oil mix, palm oil, coconut oil, rapeseed oil) could be used as alternatives to animal fat in pig feed, whereas fat...

  8. Advanced penning ion source

    Energy Technology Data Exchange (ETDEWEB)

    Schenkel, Thomas; Ji, Qing; Persaud, Arun; Sy, Amy V.

    2016-11-01

    This disclosure provides systems, methods, and apparatus for ion generation. In one aspect, an apparatus includes an anode, a first cathode, a second cathode, and a plurality of cusp magnets. The anode has a first open end and a second open end. The first cathode is associated with the first open end of the anode. The second cathode is associated with the second open end of the anode. The anode, the first cathode, and the second cathode define a chamber. The second cathode has an open region configured for the passage of ions from the chamber. Each cusp magnet of the plurality of cusp magnets is disposed along a length of the anode.

  9. Cold Strontium Ion Source for Ion Interferometry

    Science.gov (United States)

    Jackson, Jarom; Durfee, Dallin

    2015-05-01

    We are working on a cold source of Sr Ions to be used in an ion interferometer. The beam will be generated from a magneto-optical trap (MOT) of Sr atoms by optically ionizing atoms leaking out a carefully prepared hole in the MOT. A single laser cooling on the resonant transition (461 nm) in Sr should be sufficient for trapping, as we've calculated that losses to the atom beam will outweigh losses to dark states. Another laser (405 nm), together with light from the trapping laser, will drive a two photon transition in the atom beam to an autoionizing state. Supported by NSF Award No. 1205736.

  10. Laser ion source for high brightness heavy ion beam

    Science.gov (United States)

    Okamura, M.

    2016-09-01

    A laser ion source is known as a high current high charge state heavy ion source. However we place great emphasis on the capability to realize a high brightness ion source. A laser ion source has a pinpoint small volume where materials are ionized and can achieve quite uniform low temperature ion beam. Those features may enable us to realize very small emittance beams. In 2014, a low charge state high brightness laser ion source was successfully commissioned in Brookhaven National Laboratory. Now most of all the solid based heavy ions are being provided from the laser ion source for regular operation.

  11. The DCU laser ion source.

    Science.gov (United States)

    Yeates, P; Costello, J T; Kennedy, E T

    2010-04-01

    Laser ion sources are used to generate and deliver highly charged ions of various masses and energies. We present details on the design and basic parameters of the DCU laser ion source (LIS). The theoretical aspects of a high voltage (HV) linear LIS are presented and the main issues surrounding laser-plasma formation, ion extraction and modeling of beam transport in relation to the operation of a LIS are detailed. A range of laser power densities (I approximately 10(8)-10(11) W cm(-2)) and fluences (F=0.1-3.9 kJ cm(-2)) from a Q-switched ruby laser (full-width half-maximum pulse duration approximately 35 ns, lambda=694 nm) were used to generate a copper plasma. In "basic operating mode," laser generated plasma ions are electrostatically accelerated using a dc HV bias (5-18 kV). A traditional einzel electrostatic lens system is utilized to transport and collimate the extracted ion beam for detection via a Faraday cup. Peak currents of up to I approximately 600 microA for Cu(+) to Cu(3+) ions were recorded. The maximum collected charge reached 94 pC (Cu(2+)). Hydrodynamic simulations and ion probe diagnostics were used to study the plasma plume within the extraction gap. The system measured performance and electrodynamic simulations indicated that the use of a short field-free (L=48 mm) region results in rapid expansion of the injected ion beam in the drift tube. This severely limits the efficiency of the electrostatic lens system and consequently the sources performance. Simulations of ion beam dynamics in a "continuous einzel array" were performed and experimentally verified to counter the strong space-charge force present in the ion beam which results from plasma extraction close to the target surface. Ion beam acceleration and injection thus occur at "high pressure." In "enhanced operating mode," peak currents of 3.26 mA (Cu(2+)) were recorded. The collected currents of more highly charged ions (Cu(4+)-Cu(6+)) increased considerably in this mode of operation.

  12. Pig Ascaris: an important source of human ascariasis in China.

    Science.gov (United States)

    Zhou, Chunhua; Li, Min; Yuan, Keng; Deng, Shoulong; Peng, Weidong

    2012-08-01

    The aim of the present study is to detect the frequency and distribution of cross infection and hybridization of human and pig Ascaris in China. Twenty high polymorphic microsatellite loci were selected to screen 258 Ascaris worms from humans and pigs from six provinces in China. The software programs Structure, Baps and Newhybrids were used to determine the case of cross infection and hybridization of human and pig Ascaris. Results showed that cross infection was detected in all sampled locations and of the total 20 cross infection cases, 19 were indentified as human infections by pure-bred pig type Ascaris in contrast to only one case of pig infection by pure-bred human type Ascaris. Similar to the findings in cross infection, hybrid Ascaris was also detected in all locations and both host species and most of hybrids (95%) were detected from human host. The distribution of cross infection and hybrids showed significant difference between the two host species and among three categories of genotype in terms of G1, G2 and G3, and also between the south and north regions (for hybrids only). The results strongly suggest pig Ascaris as an important source of human ascariasis in endemic area where both human and pig Ascaris exist. In consideration of current control measures for human ascariasis targeting only infected people, it is urgently needed to revise current control measures by adding a simultaneous treatment to infected pigs in the sympatric endemics. The knowledge on cross transmission and hybridization between human and pig Ascaris is important not only for public health, but also for the understanding of genetic evolution, taxonomy and molecular epidemiology of Ascaris.

  13. Characterization of ISOLDE ion source and ion source chemistry

    CERN Document Server

    Barbeau, Marion

    2014-01-01

    This report presents results of measurements made with the ISOLDE OFF-LINE mass separator [1]. The first part shows measurements of the ionization characteristics of noble gases in a VADIS ion source. The goal of the measurements was to determine the dependency of the extractable current of first and second noble gases ions with the electron energy. In the second part, investigation on in-target chemistry are presented. Here, the effect of injected sulfur hexafluoride ($SF_6$) on the release of oxygen from aluminium oxide ($Al_2 O_3$) was studied.

  14. Alternative fat sources to animal fat for pigs

    OpenAIRE

    Lauridsen, Charlotte; Christensen, Thomas Bruun; Halekoh, Ulrich; Jensen, Søren Krogh

    2007-01-01

    The use of fats and oils in diets for pigs is of great importance due to their high energy value. As a consequence of the BSE-crisis in the European Union, the amount of animal fat available for animal feeds has been reduced, and alternative fat sources are of increasing importance. In this paper, we review our main findings on the effects of diets with different fat sources on apparent fat digestibility in pigs. A method for quantitative measurement of fat extraction from feed and faeces has...

  15. Improvement of penning ion sources

    CERN Document Server

    Bizyukov, A A; Kashaba, A Y; Sereda, K N

    2000-01-01

    It is shown that the loss of a longitudinal symmetry of magnetic field distribution in respect to the centre of the Penning discharge system causes change of electrostatic potential distribution in the discharge gap leads to appearance of asymmetry of current magnitude to the cathodes of the Penning cell,change of magnitude of current density and energy distribution of the ion beam extracted in a longitudinal direction.The use of an inhomogeneous magnetic field which is longitudinally asymmetrical concerning electrodes of the system allows to increase current efficiency of Penning ion sources from 0,2 to 0,55.

  16. Laser ion source studies at CERN

    CERN Document Server

    Tambini, J

    1995-01-01

    The plasma produced when a powerful laser pulse is focused onto a target surface in vacuum can provide a copious source of highly charged ions. Ions can then be extracted from the plasma to form a high current, short pulse length ion beam. Experimental laser ion sources have been the subject of investigation in medical physics and particle accelerator applications; a laser ion source is an option for the injection system of heavy ions for the Large Hadron Collider at CERN where a high intensity lead ion beam is required. This paper describes work carried out at CERN to develop a CO2 laser ion source.

  17. Cassava leaves as protein source for pigs in Central Vietnam

    NARCIS (Netherlands)

    2007-01-01

    The aim of the studies described in this thesis was to evaluate the use of cassava leaves as protein sources for pigs when used at high levels in the diet, either in fresh form or with simplified methods of processing. In twenty cassava varieties taken from the upper part of the plant at the root

  18. Nanobeam production with the multicusp ion source

    Science.gov (United States)

    Lee, Y.; Ji, Q.; Leung, K. N.; Zahir, N.

    2000-02-01

    A 1.8-cm-diam multicusp ion source to be used for focused ion beam applications has been tested for Xe, He, Ne, Ar, and Kr ions. The extractable ion and electron currents were measured. The extractable ion current is similar for all these ion species except for Ne+, but the extractable electron current behaves quite differently. The multicusp ion source will be used with a combined extractor-collimator electrode system that can provide a few hundred nA of Xe+ or Kr+ ions. Ion optics computation indicates that these beams can be further focused with an electrostatic column to a beam spot size of ˜100 nm.

  19. Control System of the H~- Ion Source

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The control system is of primary importance to the accelerator operation. This paper presents a brief introduction to the new ion source control system. The research is to build a new H- ion source based on

  20. Ion optics of RHIC electron beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Okamura, M.; Raparia, D.; Ritter, J.; Tan, Y. [Brookhaven National Laboratory, Upton, New York 11973 (United States); Kuznetsov, G. [Budker Institute of Nuclear Physics, Novosibirsk 630090 (Russian Federation)

    2012-02-15

    RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

  1. Multicusp sources for ion beam projection lithography

    Science.gov (United States)

    Lee, Y.; Gough, R. A.; Kunkel, W. B.; Leung, K. N.; Vujic, J.; Williams, M. D.; Wutte, D.; Zahir, N.

    1998-02-01

    Multicusp ion sources are capable of producing positive and negative ions with good beam quality and low energy spread. The ion energy spread of multicusp sources has been measured by three different techniques. The axial ion energy spread has been reduced by introducing a magnetic filter inside the multicusp source chamber which adjusts the plasma potential distribution. The axial energy spread is further reduced by optimizing the source configuration. Values as low as 0.8 eV have been achieved.

  2. Bioavailability of zinc from different sources in pigs.

    Science.gov (United States)

    Nitrayova, S; Windisch, W; von Heimendahl, E; Müller, A; Bartelt, J

    2012-12-01

    In contrast to inorganic Zn, organic Zn sources are absorbed via peptide or AA transport systems resulting in a higher digestibility and availability. Bioavailability of organically bound Zn seems also to be influenced by the type of complex being used. Forty-two gilts (Large white × Landrace) with initial BW of 24 ± 1.4 kg were allotted to 6 treatments of 7 pigs each. Pigs were fed diets based on corn (Zea mays), barley (Hordeum vulgare), and soybean (Glycine max) meal containing either low or high Zn supplementation with ZnO, Zn-Met 1:2 complex, Zn-Gly, Zn proteinate (Zn-Prot), or Zn-yeast. Diets were fed during a 10-d adaptation followed by a 4-d quantitative collection. Daily feed allowance was restricted to 1400 g/pig. Pigs were weighed at the start and end of adaptation and collection and feed consumption was monitored daily. Dietary Zn addition was 10 and 100 mg/kg feed for ZnO and 10 mg/kg feed for other Zn sources. Corresponding ADG ranged from 437 to 587 g with the lowest (P may reduce Zn excretion, which consequently may lower the environmental impact.

  3. Liquid metal ion source assembly for external ion injection into an electron string ion source (ESIS)

    Energy Technology Data Exchange (ETDEWEB)

    Segal, M. J., E-mail: mattiti@gmail.com [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); University of Cape Town, Rondebosch, Cape Town 7700 (South Africa); Bark, R. A.; Thomae, R. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Donets, E. E.; Donets, E. D.; Boytsov, A.; Ponkin, D.; Ramsdorf, A. [Joint Institute for Nuclear Research, Joloit-Curie 6, 141980 Dubna, Moscow Region (Russian Federation)

    2016-02-15

    An assembly for a commercial Ga{sup +} liquid metal ion source in combination with an ion transportation and focusing system, a pulse high-voltage quadrupole deflector, and a beam diagnostics system has been constructed in the framework of the iThemba LABS (Cape Town, South Africa)—JINR (Dubna, Russia) collaboration. First, results on Ga{sup +} ion beam commissioning will be presented. Outlook of further experiments for measurements of charge breeding efficiency in the electron string ion source with the use of external injection of Ga{sup +} and Au{sup +} ion beams will be reported as well.

  4. Recent progress in heavy ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Clark, D.J.

    1977-03-01

    A summary is given of the progress during the last several years in the technology of sources of high charge state positive heavy ions and negative heavy ions. Subjects covered include recent results in ECR and EBIS source development and comparison of various source types for high charge state heavy ions.

  5. A Multicusp Ion Source for Radioactive Ion Beams

    Science.gov (United States)

    Wutte, D.; Freedman, S.; Gough, R.; Lee, Y.; Leitner, M.; Leung, K. N.; Lyneis, C.; Picard, D. S.; Sun, L.; Williams, M. D.; Xie, Z. Q.

    1997-05-01

    In order to produce a radioactive ion beam of (14)O+, a 10-cm-diameter, 13.56 MHz radio frequency (rf) driven multicusp ion source is now being developed at Lawrence Berkeley National Laboratory. In this paper we describe the specific ion source design and the basic ion source characteristics using Ar, Xe and a 90types of measurements have been performed: extractable ion current, ion species distributions, gas efficiency, axial energy spread and ion beam emittance measurements. The source can generate ion current densities of approximately 60 mA/cm2 . In addition the design of the ion beam extraction/transport system for the actual experimental setup for the radioactive beam line will be presented.

  6. Laser ion source for isobaric heavy ion collider experiment.

    Science.gov (United States)

    Kanesue, T; Kumaki, M; Ikeda, S; Okamura, M

    2016-02-01

    Heavy-ion collider experiment in isobaric system is under investigation at Relativistic Heavy Ion Collider. For this experiment, ion source is required to maximize the abundance of the intended isotope. The candidate of the experiment is (96)Ru + (96)Zr. Since the natural abundance of particular isotope is low and composition of isotope from ion source depends on the composites of the target, an isotope enriched material may be needed as a target. We studied the performance of the laser ion source required for the experiment for Zr ions.

  7. Ion transport from plasma ion source at ISOLTRAP

    CERN Document Server

    Steinsberger, Timo Pascal

    2017-01-01

    In this report, my work as CERN Summer Student at the ISOLTRAP experiment at ISOLDE is described. A new plasma ion source used as oine source for calibration and implemented before my arrival was commissioned and transportation settings for the produced ions to the ion traps were found. The cyclotron frequencies of 40Ar and the xenon isotopes 129-132Xe were measured using time-of-flight and phase-imaging ion-cyclotron-resonance mass spectroscopy.

  8. Compact RF ion source for industrial electrostatic ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyeok-Jung, E-mail: hjkwon@kaeri.re.kr; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub [Korea Multi-purpose Accelerator Complex, Korea Atomic Energy Research Institute, Gyeongsangbukdo 38180 (Korea, Republic of)

    2016-02-15

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  9. The Physics and Technology of Ion Sources

    CERN Document Server

    2004-01-01

    The first edition of this title has become a well-known reference book on ion sources. The field is evolving constantly and rapidly, calling for a new, up-to-date version of the book. In the second edition of this significant title, editor Ian Brown, himself an authority in the field, compiles yet again articles written by renowned experts covering various aspects of ion source physics and technology. The book contains full chapters on the plasma physics of ion sources, ion beam formation, beam transport, computer modeling, and treats many different specific kinds of ion sources in sufficient detail to serve as a valuable reference text

  10. Multicusp sources for ion beam lithography applications

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; Herz, P.; Kunkel, W.B.; Lee, Y.; Perkins, L.; Pickard, D.; Sarstedt, M.; Weber, M.; Williams, M.D.

    1995-05-01

    Application of the multicusp source for Ion Projection Lithography is described. It is shown that the longitudinal energy spread of the positive ions at the extraction aperture can be reduced by employing a magnetic filter. The advantages of using volume-produced H{sup {minus}} ions for ion beam lithography is also discussed.

  11. Multicusp sources for ion beam lithography applications

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; Herz, P.; Kunkel, W.B.; Lee, Y.; Perkins, L.; Pickard, D.; Sarstedt, M.; Weber, M.; Williams, M.D. [Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (United States)

    1995-11-01

    Application of the multicusp source for ion projection lithography is described. It is shown that the longitudinal energy spread of the positive ions at the extraction aperture can be reduced by employing a magnetic filter. The advantages of using volume-produced H{sup {minus}} ions for ion beam lithography are also discussed. {copyright} {ital 1995} {ital American} {ital Vacuum} {ital Society}

  12. Production and ion-ion cooling of highly charged ions in electron string ion source.

    Science.gov (United States)

    Donets, D E; Donets, E D; Donets, E E; Salnikov, V V; Shutov, V B; Syresin, E M

    2009-06-01

    The scheme of an internal injection of Au atoms into the working space of the "Krion-2" electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au51+ were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au51+ ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

  13. Laser ion source with solenoid field

    Science.gov (United States)

    Kanesue, Takeshi; Fuwa, Yasuhiro; Kondo, Kotaro; Okamura, Masahiro

    2014-11-01

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 1011, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  14. The physics of Electron Beam Ion Sources

    Energy Technology Data Exchange (ETDEWEB)

    Stockli, M.P.; Cocke, C.L.

    1990-01-01

    There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th[sup 80+] and Xe[sup 53+]. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

  15. The physics of Electron Beam Ion Sources

    Energy Technology Data Exchange (ETDEWEB)

    Stockli, M.P.; Cocke, C.L.

    1990-12-31

    There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th{sup 80+} and Xe{sup 53+}. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.

  16. A Plasma Ion Source for ISOLTRAP

    CERN Document Server

    Skov, Thomas Guldager

    2016-01-01

    In this report, my work testing the new Penning ion source as a summer student at ISOLTRAP is described. The project was composed of three stages: (1) Setting up a test laboratory in building 275, (2) characterizing the ion source, and (3) implementing and testing the source in the ISOLTRAP setup. After setting up the test laboratory, the ion source was tested in a constant pressure environment with produced ion currents in the range of nA . An extensive scan of the source ion current versus operating parameters (pressure, voltage) was performed. A setup with pulsed gas flow was also tested, allowing a reduction of the gas load on the vacuum system. The behavior of the ion source together with the ISOLTRAP setup was also investigated, allowing to understand current limitations and future directions of improvement.

  17. Ion beam measurements at the superconducting ECR ion source SECRAL

    Energy Technology Data Exchange (ETDEWEB)

    Maeder, Jan; Rossbach, Jon; Lang, Ralf; Maimone, Fabio; Spaedtke, Peter; Tinschert, Klaus [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Sun, Liangting; Cao, Yun; Zhao, Hongwei [Institute of Modern Physics, Lanzhou, GS (China)

    2009-08-15

    Measurement of the charge-state distribution, the beam profile, the beam emittance of the named ion source are presented. Furthermore computer simulations of the magnetic flux-density distribution in this source are described. (HSI)

  18. CSNS H- ion source test stand

    Institute of Scientific and Technical Information of China (English)

    WU Xiao-Bing; ZHANG Jun-Song; ZHANG Hua-Shun; ZHAO Fu-Xiang; OUYANG Hua-Fu; CHI Yun-Long; HE Wei; HUANG Tao; LI Gang; LIU Ying-Man; LU Yan-Hua; XU Tao-Guang

    2011-01-01

    The Penning surface plasma source is adopted as the China Spallation Neutron Source (CSNS) H- ion source. The designed energy and beam current of the source are 50 keV and 20 mA, respectively, with a normalized root mean square(norm·rms.)emittance of 0.2πmm·mrad.The construction of a H-ion source test stand has been completed, and the commissioning of the source is in progress. Stable H- ion beams with energy of 50 keV and current up to 50 mA are attained. Emittance measurement for the H- beam is being prepared.

  19. Multicusp sources for ion beam projection lithography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.; Gough, R.A.; Kunkel, W.B.; Leung, K.N.; Vujic, J.; Williams, M.D.; Wutte, D.; Zahir, N. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    1998-02-01

    Multicusp ion sources are capable of producing positive and negative ions with good beam quality and low energy spread. The ion energy spread of multicusp sources has been measured by three different techniques. The axial ion energy spread has been reduced by introducing a magnetic filter inside the multicusp source chamber which adjusts the plasma potential distribution. The axial energy spread is further reduced by optimizing the source configuration. Values as low as 0.8 eV have been achieved. {copyright} {ital 1998 American Institute of Physics.}

  20. 11. international conference on ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Leitner, D.; Lyneis, C.; Cheng, D.; Galloway, M.L.; Leitner, M.; Todd, D.S.; Ciavola, G.; Gammino, S.; Celona, L.; Ando, L.; Torrisi, L.; Cavenago, M.; Galata, A.; Spaedtke, P.; Tinschert, K.; Lang, R.; Iannucci, R.; Leroy, R.; Barue, C.; Hitz, D.; Koivisto, H.; Suominen, P.; Tarvainen, O.; Beijers, H.; Brandenburg, S.; Vanrooyen, D.; Hillo, C.; Kuchler, D.; Homeyer, H.; Rohrich, J.; Schachter, L.; Dobrescu, S.; Nakagawa, T.; Higurashi, Y.; Kidera, M.; Aihara, T.; Kase, M.; Goto, A.; Yang, Y.; Zhao, H.W.; Zhang, Z.M.; Zhang, X.Z.; Guo, X.H.; He, W.E.; Sun, L.T.; Yuan, P.; Song, M.T.; Xie, Z.Q.; Cao, Y.; Zhan, W.L.; Wei, B.W.; Bricault, P.; Lau, C.; Essabaa, S.; Cheikh Mhamed, M.; Bajeat, O.; Ducourtieux, M.; Lefort, H.; Panteleev, V.N.; Barzakh, A.E.; Fedorov, D.V.; Ionan, A.M.; Mezilev, K.A.; Moroz, F.V.; Orlov, S.Y.; Volkov, Y.M.; Andrighetto, A.; Lhersonneau, G.; Rizzi, V.; Tecchio, L.B.; Dubois, M.; Gaubert, G.; Jardins, P.; Lecesne, N.; Leroy, R.; Pacquet, J.Y.; Saint Laurent, M.G.; Villari, A.C.O.; Bajeat, O.; Essabaa, S.; Lau, C.; Menna, M.; Franberg, H.; Ammann, M.; Gdggeler, H.W.; Koster, U.; Allen, F.; Biedermann, C.; Radtke, R.; Ames, F.; Baartman, R.; Bricault, P.; Jayamanna, K.; Lamy, T.; McDonald, M.; Olivo, M.; Schmorl, P.; Yuan, D.H.L.; Asaji, T.; Sasaki, H.; Kato, Y.; Atabaev, B.; Radjabov, S.S.; Akhmadjanova, M.K.; Yuzikaeva, F.R.; Baoqun, Cui; Liqiang, Li; Yingjun, Ma; Shengyun, Zhu; Cong, Jiang

    2005-07-01

    This document gathers the summaries of the presentations made at ICIS05 (international conference on ion sources). It can be organized into 3 main topics: 1) 'fundamentals and theory' that deals with plasma, beam extraction, transport and emittance, diagnostics and simulation; 2) 'various types of ion sources' that include ECRIS, EBIS, microwave, negative, radioactive, polarized and laser ion sources, and charge breeders; and 3) 'ion sources and applications' in fields like accelerator injection, fusion energy, space propulsion, mass spectrometry, and neutron and cluster and rare nuclide production.

  1. Electron beam ion source and electron beam ion trap (invited).

    Science.gov (United States)

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  2. Electron beam ion source and electron beam ion trap (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Reinard [Scientific Software Service, Kapellenweg 2a, D-63571 Gelnhausen (Germany); Kester, Oliver [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2010-02-15

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not ''sorcery'' but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  3. Nanobeam production with the multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States); Ji, Q. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States); Leung, K. N. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States); Zahir, N. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    2000-02-01

    A 1.8-cm-diam multicusp ion source to be used for focused ion beam applications has been tested for Xe, He, Ne, Ar, and Kr ions. The extractable ion and electron currents were measured. The extractable ion current is similar for all these ion species except for Ne{sup +}, but the extractable electron current behaves quite differently. The multicusp ion source will be used with a combined extractor-collimator electrode system that can provide a few hundred nA of Xe{sup +} or Kr{sup +} ions. Ion optics computation indicates that these beams can be further focused with an electrostatic column to a beam spot size of {approx}100 nm. (c) 2000 American Institute of Physics.

  4. Cobalt alloy ion sources for focused ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Muehle, R.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Zimmermann, P. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Cobalt alloy ion sources have been developed for silicide formation by focused ion beam implantation. Four eutectic alloys AuCo, CoGe, CoY and AuCoGe were produced by electron beam welding. The AuCo liquid alloy ion source was investigated in detail. We have measured the emission current stability, the current-voltage characteristics, and the mass spectrum as a function of the mission current. (author) 1 fig., 2 refs.

  5. Electron string ion sources for carbon ion cancer therapy accelerators

    CERN Document Server

    Boytsov, A Yu; Donets, E D; Donets, E E; Katagiri, K; Noda, K; Ponkin, D O; Ramzdorf, A Yu; Salnikov, V V; Shutov, V B

    2015-01-01

    The Electron String type of Ion Sources (ESIS) was developed, constructed and tested first in the Joint Institute for Nuclear Research. These ion sources can be the appropriate sources for production of pulsed C4+ and C6+ ion beams which can be used for cancer therapy accelerators. In fact the test ESIS Krion-6T already now at the solenoid magnetic field only 4.6 T provides more than 10^10 C4+ ions per pulse and about 5*10^9 C6+ ions per pulse. Such ion sources could be suitable for application at synchrotrons. It was also found, that Krion-6T can provide more than 10^11 C6+ ions per second at 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. As for production of 11C radioactive ion beams ESIS can be the most economic kind of ion source. To proof that the special cryogenic cell for pulse injection of gaseous species into electron string was successfully tested using the ESIS Krion-2M.

  6. Negative Ion Confinement in the Multicusp Ion Source

    Science.gov (United States)

    Khodadadi Azadboni, Fatemeh; Sedaghatizade, Mahmood

    2010-04-01

    To optimize the negative ion source and generate intense beams of negative ions, understanding of transport properties of both electrons and negative ions is indispensable. Transport process of negative hydrogen ions (H-) in a multicusp H- source, has been simulated by three-dimensional Femlab simulation software. Multipolar plasma confinement is known to result in enhanced plasma density, homogeneous plasma of a large volume, and quiescent plasmas. The effect of plasma confinement by applying multi-polar magnetic field was investigated. Results are obtained for ten different configurations of permanent magnet and discussed. Full line cusps are found to give optimum plasma density. Negative ions created on the sidewall hardly can reach the center of the source due to trapping by the multicusp magnetic field. As a result, H- ions created on the sidewall do not have a significant effect on the H- current.

  7. ION SOURCES FOR ENERGY EXTREMES OF ION IMPLANTATION.

    Energy Technology Data Exchange (ETDEWEB)

    HERSCHCOVITCH,A.; JOHNSON, B.M.; BATALIN, V.A.; KROPACHEV, G.N.; KUIBEDA, R.P.; KULEVOY, T.V.; KOLOMIETS, A.A.; PERSHIN, V.I.; PETRENKO, S.V.; RUDSKOY, I.; SELEZNEV, D.N.; BUGAEV, A.S.; GUSHENETS, V.I.; LITOVKO, I.V.; OKS, E.M.; YUSHKOV, G. YU.; MASEUNOV, E.S.; POLOZOV, S.M.; POOLE, H.J.; STOROZHENKO, P.A.; SVAROVSKI, YA.

    2007-08-26

    For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques, which meet the two energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of Antimony and Phosphorous ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb{sup 4+}, Sb{sup 5+}, and Sb{sup 6+} respectively. For low energy ion implantation our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA of positive Decaborane ions were extracted at 10 keV and smaller currents of negative Decaborane ions were also extracted. Additionally, Boron current fraction of over 70% was extracted from a Bemas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

  8. Ion sources for energy extremes of ion implantation.

    Science.gov (United States)

    Hershcovitch, A; Johnson, B M; Batalin, V A; Kropachev, G N; Kuibeda, R P; Kulevoy, T V; Kolomiets, A A; Pershin, V I; Petrenko, S V; Rudskoy, I; Seleznev, D N; Bugaev, A S; Gushenets, V I; Litovko, I V; Oks, E M; Yushkov, G Yu; Masunov, E S; Polozov, S M; Poole, H J; Storozhenko, P A; Svarovski, A Ya

    2008-02-01

    For the past four years a joint research and development effort designed to develop steady state, intense ion sources has been in progress with the ultimate goal to develop ion sources and techniques that meet the two energy extreme range needs of meV and hundreads of eV ion implanters. This endeavor has already resulted in record steady state output currents of high charge state of antimony and phosphorus ions: P(2+) [8.6 pmA (particle milliampere)], P(3+) (1.9 pmA), and P(4+) (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb(3+)Sb(4+), Sb(5+), and Sb(6+) respectively. For low energy ion implantation, our efforts involve molecular ions and a novel plasmaless/gasless deceleration method. To date, 1 emA (electrical milliampere) of positive decaborane ions was extracted at 10 keV and smaller currents of negative decaborane ions were also extracted. Additionally, boron current fraction of over 70% was extracted from a Bernas-Calutron ion source, which represents a factor of 3.5 improvement over currently employed ion sources.

  9. CERN PS laser ion source development

    CERN Document Server

    Fournier, P; Haseroth, H; Khomenko, S; Kondrashev, S A; Kugler, H; Lisi, N; Lombardi, A M; Makarov, K; Meyer, C; Ostroumov, P N; Pirkl, Werner; Rörich, V; Roudskoy, I; Satov, Yu A; Schnuriger, J C; Scrivens, R; Sharkov, B Yu; Shumshurov, A V; Stepanov, A; Tenishev, V; Varelá-Rodriguez, F

    1999-01-01

    CERN, together with ITEP and TRINITI (Russia), is developing a CO2 laser ion source. The key design parameters are: 1.4 1010 ions of Pb25+ in a pulse of 5.5 ms, with a 4-rms emittance of 0.2 10-6 rad m, working at a repetition rate of 1 Hz. This device is considered as one candidate source for LHC heavy ion operation. The status of the laser development, the experimental set-up of the source consisting of the target area and its illumination, the plasma expansion area and extraction, beam transport and ion pre-acceleration by an RFQ, will be given.

  10. Laser Ion Source Project at IGISOL

    Energy Technology Data Exchange (ETDEWEB)

    Nieminen, A. [University of Manchester, Department of Physics and Astronomy (United Kingdom); Moore, I. D., E-mail: iain.moore@php.jyu.fi [University of Jyvaeskylae, Department of Physics (Finland); Billowes, J.; Campbell, P.; Flanagan, K. T. [University of Manchester, Department of Physics and Astronomy (United Kingdom); Geppert, Ch. [University of Mainz, Institut fuer Physik (Germany); Huikari, J.; Jokinen, A. [University of Jyvaeskylae, Department of Physics (Finland); Kessler, T. [University of Mainz, Institut fuer Physik (Germany); Marsh, B. [University of Manchester, Department of Physics and Astronomy (United Kingdom); Penttilae, H.; Rinta-Antila, S. [University of Jyvaeskylae, Department of Physics (Finland); Tordoff, B. [University of Manchester, Department of Physics and Astronomy (United Kingdom); Wendt, K. D. A. [University of Mainz, Institut fuer Physik (Germany); Aystoe, J. [University of Jyvaeskylae, Department of Physics (Finland)

    2005-04-15

    The application of laser ionisation is being developed for the IGISOL mass separator facility in Jyvaeskylae, Finland. The conceived laser ion source will have two independent pulsed laser systems based on all solid-state lasers and dye lasers for maximal coverage of ionisation schemes throughout the periodic table. A laser ion source trap, LIST, method will be pursued for optimal selectivity.

  11. GANIL Workshop on Ion Sources; Journees Sources d'Ions

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Renan [Grand Accelerateur National d' Ions Lourds (GANIL), 14 - Caen (France)

    1999-07-01

    The proceedings of the GANIL Workshop on Ion Sources held at GANIL - Caen on 18-19 March 1999 contains 13 papers aiming at improving the old source operation and developing new types of sources for nuclear research and studies of ion physics. A number of reports are devoted to applications like surface treatment, ion implantation or fusion injection. The 1+{yields}n+ transformation, charged particle transport in ECR sources, addition of cesium and xenon in negative ion sources and other basic issues in ion sources are also addressed.

  12. Mass spectrometry in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Mullan, A.A. (Applied Physical Science, University of Ulster, Coleraine (Northern Ireland)); Graham, W.G. (Physics Department, Queen' s University, Belfast, (Northern Ireland))

    1990-08-05

    Mass spectrometry has been used for the detection of positive and negative ions in a multicusp ion source operating with both hydrogen and deuterium gas. The mass spectrometer operation has been optimized and it is shown that applying ion extraction voltages can disturb the discharge. Using this technique combined with a Langmuir probe technique we are able to study the positive ionic fractions present when operating with both gases (and the negative ion densities.)

  13. Peltier Refrigerators for Molecular Ion Sources

    Science.gov (United States)

    Hershcovitch, Ady

    2008-11-01

    Molecular ion sources have been considered for various applications. In particular, there is considerable effort to develop decaborane and octadecaborane ion sources for the semiconductor industry. Since the invention of the transistor, the trend has been to miniaturize semiconductor devices. As semiconductors become smaller (and get miniaturized), ion energy needed for implantation decreases, since shallow implantation is desired. But, due to space charge (intra-ion repulsion) effects, forming and transporting ion beams becomes a rather difficult task. These problems associated with lower energy ion beams limit implanter ion currents, thus leading to low production rates. One way to tackle the space charge problem is to use singly charged molecular ions. A crucial aspect in generating large molecular ion beam currents is ion source temperature control. Peltier coolers, which have in the past successfully utilized in BaF2 and CSI gamma ray detectors, may be ideal for this application. Clogging prevention of molecular ion sources is also a hurdle, which was overcome with special slots. Both topics are to be presented.

  14. Radio frequency multicusp ion source development (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    1996-03-01

    The radio-frequency (rf) driven multicusp source was originally developed for use in the Superconducting Super Collider injector. It has been demonstrated that the source can meet the H{sup {minus}} beam current and emittance requirements for this application. By employing a porcelain-coated antenna, a clean plasma discharge with very long-life operation can be achieved. Today, the rf source is used to generate both positive and negative hydrogen ion beams and has been tested in various particle accelerator laboratories throughout the world. Applications of this ion source have been extended to other fields such as ion beam lithography, oil-well logging, ion implantation, accelerator mass spectrometry and medical therapy machines. This paper summarizes the latest rf ion source technology and development at the Lawrence Berkeley National Laboratory. {copyright} {ital 1996 American Institute of Physics.}

  15. Radio frequency multicusp ion source development (invited)

    Science.gov (United States)

    Leung, K. N.

    1996-03-01

    The radio-frequency (rf) driven multicusp source was originally developed for use in the Superconducting Super Collider injector. It has been demonstrated that the source can meet the H- beam current and emittance requirements for this application. By employing a porcelain-coated antenna, a clean plasma discharge with very long-life operation can be achieved. Today, the rf source is used to generate both positive and negative hydrogen ion beams and has been tested in various particle accelerator laboratories throughout the world. Applications of this ion source have been extended to other fields such as ion beam lithography, oil-well logging, ion implantation, accelerator mass spectrometry and medical therapy machines. This paper summarizes the latest rf ion source technology and development at the Lawrence Berkeley National Laboratory.

  16. CSNS H^- ion source test stand

    Institute of Scientific and Technical Information of China (English)

    吴小兵; 张俊嵩; 张华顺; 赵富祥; 欧阳华甫; 池云龙; 何伟; 黄涛; 李刚; 刘应满; 卢艳华; 徐韬光

    2011-01-01

    The Penning surface plasma source is adopted as the China Spallation Neutron Source (CSNS) H^- ion source. The designed energy and beam current of the source are 50 keV and 20 mA, respectively, with a normalized root mean square (norm. rms.) emittance of

  17. Performance of an inverted ion source

    Energy Technology Data Exchange (ETDEWEB)

    Salvadori, M. C.; Teixeira, F. S.; Sgubin, L. G.; Araujo, W. W. R.; Spirin, R. E. [Institute of Physics, University of Sao Paulo, C.P. 66318, CEP 05315-970, Sao Paulo S.P. (Brazil); Oks, E. M. [State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Brown, I. G. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2013-02-15

    Whereas energetic ion beams are conventionally produced by extracting ions (say, positive ions) from a plasma that is held at high (positive) potential, with ion energy determined by the potential drop through which the ions fall in the beam formation electrode system, in the device described here the plasma and its electronics are held at ground potential and the ion beam is formed and injected energetically into a space maintained at high (negative) potential. We refer to this configuration as an 'inverted ion source.' This approach allows considerable savings both technologically and economically, rendering feasible some ion beam applications, in particular small-scale ion implantation, that might otherwise not be possible for many researchers and laboratories. We have developed a device of this kind utilizing a metal vapor vacuum arc plasma source, and explored its operation and beam characteristics over a range of parameter variation. The downstream beam current has been measured as a function of extraction voltage (5-35 kV), arc current (50-230 A), metal ion species (Ti, Nb, Au), and extractor grid spacing and beamlet aperture size (3, 4, and 5 mm). The downstream ion beam current as measured by a magnetically-suppressed Faraday cup was up to as high as 600 mA, and with parametric variation quite similar to that found for the more conventional metal vapor vacuum arc ion source.

  18. Plasma-Based Ion Beam Sources

    Energy Technology Data Exchange (ETDEWEB)

    Loeb, H. W.

    2005-07-01

    Ion beam sources cover a broad spectrum of scientific and technical applications delivering ion currents between less than 1 mA and about 100 A at acceleration voltages between 100 V and 100 kV. The ions are mostly generated by electron collisions in a gas discharge and then extracted from the discharge plasma, focused and post-accelerated by single- or multi-aperture electrode systems. Some important applications require the neutralization of the exhausted beam either by charge exchange or by admixture of electrons. In the first part of the paper, the theory of ionization by electron impact, the energy and carrier balances in the plasma, and the extraction and focusing mechanisms will be outlined. The principles of the preferred gas discharges and of the ion beam sources based on them are discussed; i.e. of the Penning, bombardment, arc, duoplasmatron, radio frequency, and microwave types. In the second part of the paper, the special requirements of the different applications are described together with the related source hardware. One distinguishes: 1. Single-aperture ion sources producing protons, heavy ions, isotope ions, etc. for particle accelerators, ion microprobes, mass spectrometers, isotope separators, etc.; quality determinative quantities are brightness, emittance, energy width, etc. 2. Broad-beam multi-aperture injector sources for fusion machines with positive or negative deuterium ions; very high beam densities, small portions of molecular ions, flat beam profiles with small divergence angles, etc. are required. 3. Broad-beam multi-aperture ion thrusters for space propulsion operated with singly charged xenon ions; high efficiencies, reliable operation, and long lifetimes are most important. Spin-offs are applied in industry for material processing. Referring to these applications, the following sources will be described in some detail: 1. Cold cathode and filament driven sources, capillary arc and plasmatron types, microwave and ECR-sources. 2

  19. Ion Sources for MedAustron

    CERN Document Server

    Lettry, J; Wallner, J; Sargsyan, E; CERN. Geneva. BE Department

    2010-01-01

    The MedAustron Ion therapy center will be constructed in Wiener Neustadt (Austria) in the vicinity of Vienna. Its accelerator complex consists of four ion sources, a linear accelerator, a synchrotron and a beam delivery system to the three medical treatment rooms and to the research irradiation room. The ion sources shall deliver beams of H31+, C4+ and light ions with utmost reliability and stability. This paper describes the features of the ion sources presently planned for the MedAustron facility; such as ion source main parameters, gas injection, temperature control and cooling systems. A dedicated beam diagnostics technique is proposed in order to characterize ECR ions beams; in the first drift region after the ion source, a fraction of the mixed beam is selected via moveable aperture. With standard beam diagnostics, we then aim to produce position-dependant observables such as ion-current density, beam energy distribution and emittance for each charge states to be compared to simulations of ECR e-heating...

  20. New Developments of a Laser Ion Source for Ion Synchrotrons

    CERN Document Server

    Kondrashev, S; Konukov, K; Sharkov, B Yu; Shumshurov, A V; Camut, O; Chamings, J A; Kugler, H; Scrivens, R; Charushin, A; Makarov, K; Satov, Yu; Smakovskii, Yu

    2004-01-01

    Laser Ion Sources (LIS) are well suited to filling synchrotron rings with highly charged ions of almost any element in a single turn injection mode. We report the first measurements of the LIS output parameters for Pb27+ ions generated by the new 100 J/1 Hz Master Oscillator - Power Amplifier CO2-laser system. A new LIS has been designed, built and tested at CERN, as an ion source for ITEP-TWAC accelerator/accumulator facility, and as a possible future source for an upgrade of the Large Hadron Collider (LHC) injector chain. The use of the LIS based on 100 J/1 Hz CO2-laser together with the new ion LINAC, as injector for ITEP-TWAC project, is discussed..

  1. The Frankfurt RF-driven ion source

    CERN Document Server

    Beller, Peter; Klein, H; Maaser, A; Volk, K; Weber, M

    2000-01-01

    An RF-driven volume ion source based on the high efficiency ion source (HIEFS) has been developed at the Institut fuer Angewandte Physik in Frankfurt. The RF-driven ion source operates at a frequency of 3.5 MHz with a maximum duty factor of 10%. Using an 11 kW RF-amplifier a He sup + -beam with a current of 82 mA as well as an oxygen beam with a current of 39 mA and an O sup + -fraction of 90% could be extracted. Experiments were done to study the operating conditions of the ion source. For the working gases helium and oxygen the emission current density in dependence on several ion source parameters was investigated. Furthermore, the energy distribution of the electrons and ions in the plasma as well as the beam composition for several working gases were studied. This article will give a detailed description of the ion source and the experimental setup. In addition, various dependencies between the plasma parameters and the emission current density, the energy distribution of electrons and ions and the beam ...

  2. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Weber, M.; Williams, M.D.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 micron patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  3. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  4. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Weber, M.; Williams, M.D. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    1996-03-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma. {copyright} {ital 1996 American Institute of Physics.}

  5. Beam emittance measurements on multicusp ion sources

    Science.gov (United States)

    Sarstedt, M.; Lee, Y.; Leung, K. N.; Perkins, L. T.; Pickard, D. S.; Weber, M.; Williams, M. D.

    1996-03-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma.

  6. Characteristics of MINI ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Yuichi; Yokota, Watalu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A very compact electron cyclotron resonance ion source (MINI ECR) was manufactured to extend available energy ranges of ion beams by applying multiply charged ions to electrostatic accelerators. The magnetic field to confine a plasma is formed only by small permanent magnets and the microwave power up to 15 W is generated by a compact transistor amplifier in order to install the ion source at a narrow high-voltage terminal where the electrical power feed is restricted. The magnet assembly is 12 cm in length and 11 cm in diameter, and forms a mirror field with the maximum strength of 0.55 T. The total power consumption of the source is below 160 W. The performance of the source was tested in a bench stand. The results of Ar, Xe, O, and N ion generation are reported in this paper. (author)

  7. An ion-optical bench for testing ion source lenses

    Science.gov (United States)

    Stoffels, J. J.; Ells, D. R.

    1988-06-01

    An ion-optical bench has been designed and constructed to obtain experimental data on the focusing properties of ion lenses in three dimensions. The heart of the apparatus is a position-sensitive detector (PSD) that gives output signals proportional to the x and y positions of each ion impact. The position signals can be displayed on an oscilloscope screen and analyzed by a two-parameter pulse-height analyzer, thereby giving a visual picture of the ion beam cross section and intensity distribution. The PSD itself is mounted on a track and is movable during operation from a position immediately following the ion lens to 30 cm away. This enables the rapid collection of accurate data on the intensity distribution and divergence angles of ions leaving the source lens. Examples of ion lens measurements are given.

  8. Review of polarized ion sources (invited).

    Science.gov (United States)

    Zelenski, A

    2010-02-01

    Recent progress in polarized ion sources development is reviewed. New techniques for production of polarized H(-) ion (proton), D(-) (D(+)), and (3)He(++) ion beams are discussed. Feasibility studies of these techniques are in progress at BNL and other laboratories. Polarized deuteron beams will be required for the polarization program at the Dubna Nuclotron and at the deuteron electric dipole moment experiment at BNL. Experiments with polarized (3)He(++) ion beams are a part of the experimental program at the future electron ion collider.

  9. Composition and biogas yield of a novel source segregation system for pig excreta

    NARCIS (Netherlands)

    Vu, Phuong T.; Melse, Roland W.; Zeeman, Grietje; Groot Koerkamp, Peter W.G.

    2016-01-01

    The performance of a novel source segregation method for pig excreta (a V-shaped conveyor belt underneath the slatted pen floor) was compared to conventional separation methods for pig slurry (screw press, centrifugation, flocculation with/without centrifugation). For the source segregation

  10. Composition and biogas yield of a novel source segregation system for pig excreta

    NARCIS (Netherlands)

    Vu, Phuong T.; Melse, Roland W.; Zeeman, Grietje; Groot Koerkamp, Peter W.G.

    2016-01-01

    The performance of a novel source segregation method for pig excreta (a V-shaped conveyor belt underneath the slatted pen floor) was compared to conventional separation methods for pig slurry (screw press, centrifugation, flocculation with/without centrifugation). For the source segregation syste

  11. Electrospray ion source with reduced analyte electrochemistry

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary J

    2013-07-30

    An electrospray ion (ESI) source and method capable of ionizing an analyte molecule without oxidizing or reducing the analyte of interest. The ESI source can include an emitter having a liquid conduit, a working electrode having a liquid contacting surface, a spray tip, a secondary working electrode, and a charge storage coating covering partially or fully the liquid contacting surface of the working electrode. The liquid conduit, the working electrode and the secondary working electrode can be in liquid communication. The electrospray ion source can also include a counter electrode proximate to, but separated from, said spray tip. The electrospray ion source can also include a power system for applying a voltage difference between the working electrodes and a counter-electrode. The power system can deliver pulsed voltage changes to the working electrodes during operation of said electrospray ion source to minimize the surface potential of the charge storage coating.

  12. The prototype of radioactive ion source

    CERN Document Server

    Aleksandrov, A V; Kot, N K; Andrighetto, A; Stroe, L

    2001-01-01

    The design and experimental results of the RIB source prototype are presented.A source will have the container of sup 2 sup 3 sup 5 U compounds heated up to 2200-2500 degree C. Vapors of uranium fission obtained when the ion source is irradiated by the high-energy neutron flux, are then ionized and extracted from the source. In the experiments with the prototype loaded by sup 1 sup 2 C the source working temperature 2700 degree C was reached, the carbon ion current 10 nA was obtained. The total operation time of more than 100 hours with no performance degradation was demonstrated.

  13. Development of a microwave ion source for ion implantations

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, N., E-mail: Nbk-Takahashi@shi.co.jp; Murata, H.; Kitami, H.; Mitsubori, H.; Sakuraba, J.; Soga, T.; Aoki, Y.; Katoh, T. [Technology Research Center, Sumitomo Heavy Industries Ltd., Yokosuka, Kanagawa 237-8555 (Japan)

    2016-02-15

    A microwave ion source is expected to have a long lifetime, as it has fewer consumables. Thus, we are in the process of developing a microwave ion source for ion implantation applications. In this paper, we report on a newly developed plasma chamber and the extracted P{sup +} beam currents. The volume of the plasma chamber is optimized by varying the length of a boron nitride block installed within the chamber. The extracted P{sup +} beam current is more than 30 mA, at a 25 kV acceleration voltage, using PH{sub 3} gas.

  14. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  15. H- ion source developments at the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Welton, Robert F [ORNL; Stockli, Martin P [ORNL; Murray Jr, S N [ORNL; Pennisi, Terry R [ORNL; Han, Baoxi [ORNL; Kang, Yoon W [ORNL; Goulding, Richard Howell [ORNL; Crisp, Danny W [ORNL; Sparks, Dennis O [ORNL; Luciano, Nicholas P [ORNL; Carmichael, Justin R [ORNL; Carr, Jr, Jerry [ORNL

    2008-01-01

    The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H- beam currents than can be produced from conventional ion sources such as the base line SNS source. H- currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with an rms emittance of 0.20-0.35 Pi mm mrad and a ~7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on RF excitation. First, the performance characteristics of an external antenna source based on an Al2O3 plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H- ion source will also be presented.

  16. High current ion source development at Frankfurt

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1995-11-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H{sup -}-sources each delivering a 70 mA H{sup -}-beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs.

  17. Enhancing the performances of ECR Ion Sources

    Energy Technology Data Exchange (ETDEWEB)

    Alton, G.D.; Liu, Y.

    1999-03-29

    The performances of ECR ion sources can be enhanced in the spatial domain by tailoring the central magnetic field so that it is uniformly distributed over a large plasma volume and is of magnitude so as to be in resonance with single frequency microwave radiation. Analogously, the performances of conventional minimum-B ECR ion sources can be enhanced in the frequency domain by injecting multiple discrete frequency or broadband microwave radiation into their plasma volumes. In this report, examples of both the spatial-and frequency-domain techniques will be given. For example, the design aspects of an all permanent-magnet ''volume-type'' (spatial-domain) ECR ion source will be described and the effects of injecting multiple frequencies (frequency-domain) on the charge-state-distributions extracted from a conventional minimum-B ECR ion source will be presented.

  18. A negative ion source test facility

    Science.gov (United States)

    Melanson, S.; Dehnel, M.; Potkins, D.; Theroux, J.; Hollinger, C.; Martin, J.; Philpott, C.; Stewart, T.; Jackle, P.; Williams, P.; Brown, S.; Jones, T.; Coad, B.; Withington, S.

    2016-02-01

    Progress is being made in the development of an Ion Source Test Facility (ISTF) by D-Pace Inc. in collaboration with Buckley Systems Ltd. in Auckland, NZ. The first phase of the ISTF is to be commissioned in October 2015 with the second phase being commissioned in March 2016. The facility will primarily be used for the development and the commercialization of ion sources. It will also be used to characterize and further develop various D-Pace Inc. beam diagnostic devices.

  19. A negative ion source test facility

    Energy Technology Data Exchange (ETDEWEB)

    Melanson, S.; Dehnel, M., E-mail: morgan@d-pace.com; Potkins, D.; Theroux, J.; Hollinger, C.; Martin, J.; Stewart, T.; Jackle, P.; Withington, S. [D-Pace, Inc., P.O. Box 201, Nelson, British Columbia V1L 5P9 (Canada); Philpott, C.; Williams, P.; Brown, S.; Jones, T.; Coad, B. [Buckley Systems Ltd., 6 Bowden Road, Mount Wellington, Auckland 1060 (New Zealand)

    2016-02-15

    Progress is being made in the development of an Ion Source Test Facility (ISTF) by D-Pace Inc. in collaboration with Buckley Systems Ltd. in Auckland, NZ. The first phase of the ISTF is to be commissioned in October 2015 with the second phase being commissioned in March 2016. The facility will primarily be used for the development and the commercialization of ion sources. It will also be used to characterize and further develop various D-Pace Inc. beam diagnostic devices.

  20. Negative ion source with external RF antenna

    Science.gov (United States)

    Leung, Ka-Ngo; Hahto, Sami K.; Hahto, Sari T.

    2007-02-13

    A radio frequency (RF) driven plasma ion source has an external RF antenna, i.e. the RF antenna is positioned outside the plasma generating chamber rather than inside. The RF antenna is typically formed of a small diameter metal tube coated with an insulator. An external RF antenna assembly is used to mount the external RF antenna to the ion source. The RF antenna tubing is wound around the external RF antenna assembly to form a coil. The external RF antenna assembly is formed of a material, e.g. quartz, which is essentially transparent to the RF waves. The external RF antenna assembly is attached to and forms a part of the plasma source chamber so that the RF waves emitted by the RF antenna enter into the inside of the plasma chamber and ionize a gas contained therein. The plasma ion source is typically a multi-cusp ion source. A converter can be included in the ion source to produce negative ions.

  1. Energy spread of ion beams generated in multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Herz, P.; Kunkel, W.B. [and others

    1995-04-01

    For the production of future microelectronics devices, various alternate methods are currently being considered to replace the presently used method of lithography with ion beam lithography. One of these methods is the Ion Projection Lithography (IPL), which aims at the possibility of projecting sub-0.25 {mu}m patterns of a stencil mask onto a wafer substrate. In order to keep the chromatic aberrations below 25 nm, an ion source which delivers a beam with energy spread of less than 3 eV is desired. For this application, multicusp ion sources are being considered. We measure the longitudinal energy spread of the plasma ions by using a two-grid electrostatic energy analyzer. The energy spread of the extracted beam is measured by a high-voltage retarding-field energy analyzer. In order to obtain the transverse ion temperature, a parallel-plate scanner is being set up to study the beam emittance. In this paper, comparisons are made for different ion source configurations.

  2. Polarized ion source operation at IUCF

    Energy Technology Data Exchange (ETDEWEB)

    Derenchuk, V. [Indiana University Cyclotron Facility, Bloomington, Indiana 47408 (United States); Belov, A. [Institute for Nuclear Research of the Russian Academy of Sciences, Moscow, 117312, Russian Federation (Russian Federation); Brown, R.; Collins, J.; Sowinski, J.; Stephenson, E.; Wedekind, M. [Indiana University Cyclotron Facility, Bloomington, Indiana 47408 (United States)

    1995-07-15

    The IUCF high intensity polarized ion source (HIPIOS), based on the source in operation at TUNL (1) and employing cold ({similar_to}30 K) atomic beam technology with an electron cyclotron resonance ionizer, has recently delivered beam to the first users. The results of the development work required to make the source operate reliably, with reasonable beam parameters are described. Methods used to measure the polarization and possible sources of unpolarized background are also discussed.

  3. Molecular ion sources for low energy semiconductor ion implantation (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, A., E-mail: hershcovitch@bnl.gov [Brookhaven National Laboratory, Upton, New York 11973 (United States); Gushenets, V. I.; Bugaev, A. S.; Oks, E. M.; Vizir, A.; Yushkov, G. Yu. [High Current Electronics Institute, Siberian Branch of Russian Academy of Sciences, Tomsk 634055 (Russian Federation); Seleznev, D. N.; Kulevoy, T. V.; Kozlov, A.; Kropachev, G. N.; Kuibeda, R. P.; Minaev, S. [Institute for Theoretical and Experimental Physics, Moscow 117218 (Russian Federation); Dugin, S.; Alexeyenko, O. [State Scientific Center of the Russian Federation State Research Institute for Chemistry and Technology of Organoelement Compounds, Moscow (Russian Federation)

    2016-02-15

    Smaller semiconductors require shallow, low energy ion implantation, resulting space charge effects, which reduced beam currents and production rates. To increase production rates, molecular ions are used. Boron and phosphorous (or arsenic) implantation is needed for P-type and N-type semiconductors, respectively. Carborane, which is the most stable molecular boron ion leaves unacceptable carbon residue on extraction grids. A self-cleaning carborane acid compound (C{sub 4}H{sub 12}B{sub 10}O{sub 4}) was synthesized and utilized in the ITEP Bernas ion source resulting in large carborane ion output, without carbon residue. Pure gaseous processes are desired to enable rapid switch among ion species. Molecular phosphorous was generated by introducing phosphine in dissociators via 4PH{sub 3} = P{sub 4} + 6H{sub 2}; generated molecular phosphorous in a pure gaseous process was then injected into the HCEI Calutron-Bernas ion source, from which P{sub 4}{sup +} ion beams were extracted. Results from devices and some additional concepts are described.

  4. Laser ion source for particle accelerators

    CERN Document Server

    Sherwood, T R

    1995-01-01

    There is an interest in accelerating atomic nuclei to produce particle beams for medical therapy, atomic and nuclear physics, inertial confinement fusion and particle physics. Laser Ion Sources, in which ions are extracted from plasma created when a high power density laser beam pulse strikes a solid surface in a vacuum, are not in common use. However, some new developments in which heavy ions have been accelerated show that such sources have the potential to provide the beams required for high-energy accelerator systems.

  5. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.

    Science.gov (United States)

    Kondo, K; Yamamoto, T; Sekine, M; Okamura, M

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  6. Negative hydrogen ion sources for accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, D.P.; /Fermilab; Peters, J.; /DESY; Sherman, J.; /Los Alamos

    2005-08-01

    A variety of H{sup -} ion sources are in use at accelerator laboratories around the world. A list of these ion sources includes surface plasma sources with magnetron, Penning and surface converter geometries as well as magnetic-multipole volume sources with and without cesium. Just as varied is the means of igniting and maintaining magnetically confined plasmas. Hot and cold cathodes, radio frequency, and microwave power are all in use, as well as electron tandem source ignition. The extraction systems of accelerator H{sup -} ion sources are highly specialized utilizing magnetic and electric fields in their low energy beam transport systems to produce direct current, as well as pulsed and/or chopped beams with a variety of time structures. Within this paper, specific ion sources utilized at accelerator laboratories shall be reviewed along with the physics of surface and volume H{sup -} production in regard to source emittance. Current research trends including aperture modeling, thermal modeling, surface conditioning, and laser diagnostics will also be discussed.

  7. Sensory analysis of meat from pigs fed with diets containing different microbial biomasses as protein source

    NARCIS (Netherlands)

    Veldman, M.; Schelvis-Smit, A.A.M.

    2004-01-01

    This study was carried out to evaluate the effects of using PL73 and PT73 as a dietary protein source in pig diets at a level of 12% over the body weight range of about 30 to 105 kg on the sensory quality of the meat obtained from these pigs.

  8. Saddle antenna radio frequency ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Dudnikov, V., E-mail: vadim@muonsinc.com; Johnson, R. [Muons, Inc., Batavia, Illinois 60510 (United States); Murray, S.; Pennisi, T.; Santana, M.; Piller, C.; Stockli, M.; Welton, R. [ORNL, Oak Ridge, Tennessee 37831 (United States); Breitschopf, J. [TLU, Seguin, Texas 78155 (United States); Dudnikova, G. [UMD, College Park, Maryland 32611 (United States); Institute of Computational Technologies SBRAS, Novosibirsk (Russian Federation)

    2016-02-15

    Existing RF ion sources for accelerators have specific efficiencies for H{sup +} and H{sup −} ion generation ∼3–5 mA/cm{sup 2} kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) surface plasma source (SPS) described here was developed to improve H{sup −} ion production efficiency, reliability, and availability. In SA RF ion source, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm{sup 2} kW. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power ∼1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with ∼4 kW RF. Continuous wave (CW) operation of the SA SPS has been tested on the test stand. The general design of the CW SA SPS is based on the pulsed version. Some modifications were made to improve the cooling and cesiation stability. CW operation with negative ion extraction was tested with RF power up to ∼1.2 kW in the plasma with production up to Ic = 7 mA. A stable long time generation of H{sup −} beam without degradation was demonstrated in RF discharge with AlN discharge chamber.

  9. Liquid metal ion source analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Marriott, P.

    1986-06-14

    An analysis system for angular and mass resolved energy distribution measurements of liquid metal ion source beams has been constructed. The energy analyser has been calibrated, and preliminary on-axis energy distribution measurements of a gallium source operating between 0.26 and 30.0 ..mu..A have been made. These results closely agree with measurements reported by other workers, confirming the unusual FWHM behaviour of gallium sources below approx. 2 ..mu..A.

  10. Design study of primary ion provider for relativistic heavy ion collider electron beam ion source.

    Science.gov (United States)

    Kondo, K; Kanesue, T; Tamura, J; Okamura, M

    2010-02-01

    Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

  11. Ion source based on the cathodic arc

    Science.gov (United States)

    Sanders, David M.; Falabella, Steven

    1994-01-01

    A cylindrically symmetric arc source to produce a ring of ions which leave the surface of the arc target radially and are reflected by electrostatic fields present in the source to a point of use, such as a part to be coated. An array of electrically isolated rings positioned in the source serves the dual purpose of minimizing bouncing of macroparticles and providing electrical insulation to maximize the electric field gradients within the source. The source also includes a series of baffles which function as a filtering or trapping mechanism for any macroparticles.

  12. Vacuum arc ion source development at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Spaedtke, P.; Emig, H.; Wolf, B.H. [GSI Darmstadt (Germany)

    1996-08-01

    Ion beams produced by the Mevva ion source are well suited for the injection into a synchrotron accelerator due to the low repetition rate (0.2 ... 5 Hz, the higher repetition rate is for the optimization of the linear accelerator only) and the short pulse length (up to 0.5ms). From the beginning of the authors experience with the Mevva ion source at GSI they tried to improve the reliability of pulse-to-pulse reproducibility and to minimize the noise on the extracted ion beam. For accelerator application this is highly necessary, otherwise the accelerator tuning and optimization becomes very difficult or even impossible. Already the beam transport becomes difficult for a noisy beam, because space charge compensation can be destroyed (at least partially). Furthermore a noisy dc-beam results in some rf-buckets which might be even empty.

  13. LINAC4 - The Ion Source

    CERN Document Server

    Haugaa, Olav

    2013-01-01

    My summer student project has been split in three parts. During the first 4-5 weeks I was involved in the design of the filtermagnets for the IS02 with the simulation tool Opera. After this, I have performed data analysis of the plasma light emission in the IS01 source with the software Matlab and I took part in the development of a Fortran code for plasma simulations. In all projects, understanding plasma physics has been essential and the learning outcome related to this field has been very high.

  14. Plasma ion sources and ion beam technology inmicrofabrications

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Lili [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 μm-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance (25

  15. Beam investigations at a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H. (Institut fuer Angewandte Physik der Johann Wolfgang Goethe-Universitaet, Robert-Mayer-Strasse 2-4, D-6000 Frankfurt am Main (Germany)); Leung, K.N. (Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (United States))

    1992-04-01

    In cooperation with the Lawrence Berkeley Laboratory, a multicusp ion source has been investigated. The goal of these investigations is to generate a nearly pure atomic nitrogen (N{sup +}) ion beam. To achieve this, the discharge chamber is divided into two parts of different plasma parameters by means of a filter magnetic field. As beam diagnostics, a bending magnet and a faraday cup have been used. Measurements of the beam current density and the ion composition for a wide range of discharge conditions have been performed. By using a Langmuir probe, we have performed measurements of electron temperature and electron density.

  16. Ion source design for industrial applications

    Science.gov (United States)

    Kaufman, H. R.; Robinson, R. S.

    1981-01-01

    The more frequently used design techniques for the components of broad-beam electron bombardment ion sources are discussed. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, the cathodes, and the magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. A comparison is made between two-grid and three-grid optics. The designs presented are representative of current technology and are adaptable to a wide range of configurations.

  17. Ion plating with an induction heating source

    Science.gov (United States)

    Spalvins, T.; Brainard, W. A.

    1976-01-01

    Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

  18. Ion source design for industrial applications

    Science.gov (United States)

    Kaufman, H. R.; Robinson, R. S.

    1981-01-01

    The more frequently used design techniques for the components of broad-beam electron bombardment ion sources are discussed. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, the cathodes, and the magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. A comparison is made between two-grid and three-grid optics. The designs presented are representative of current technology and are adaptable to a wide range of configurations.

  19. Optical surfacing via linear ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Lixiang, E-mail: wulx@hdu.edu.cn [Key Lab of RF Circuits and Systems of Ministry of Education, Zhejiang Provincial Key Lab of LSI Design, Microelectronics CAD Center, College of Electronics and Information, Hangzhou Dianzi University, Hangzhou (China); Wei, Chaoyang, E-mail: siomwei@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Shao, Jianda, E-mail: jdshao@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China)

    2017-04-15

    We present a concept of surface decomposition extended from double Fourier series to nonnegative sinusoidal wave surfaces, on the basis of which linear ion sources apply to the ultra-precision fabrication of complex surfaces and diffractive optics. The modified Fourier series, or sinusoidal wave surfaces, build a relationship between the fabrication process of optical surfaces and the surface characterization based on power spectral density (PSD) analysis. Also, we demonstrate that the one-dimensional scanning of linear ion source is applicable to the removal of mid-spatial frequency (MSF) errors caused by small-tool polishing in raster scan mode as well as the fabrication of beam sampling grating of high diffractive uniformity without a post-processing procedure. The simulation results show that optical fabrication with linear ion source is feasible and even of higher output efficiency compared with the conventional approach.

  20. The RHIC polarized H- ion source

    Science.gov (United States)

    Zelenski, A.; Atoian, G.; Raparia, D.; Ritter, J.; Steski, D.

    2016-02-01

    A novel polarization technique had been successfully implemented for the Relativistic Heavy Ion Collider (RHIC) polarized H- ion source upgrade to higher intensity and polarization. In this technique, a proton beam inside the high magnetic field solenoid is produced by ionization of the atomic hydrogen beam (from external source) in the He-gaseous ionizer cell. Further proton polarization is produced in the process of polarized electron capture from the optically pumped Rb vapor. The use of high-brightness primary beam and large cross sections of charge-exchange cross sections resulted in production of high intensity H- ion beam of 85% polarization. The source very reliably delivered polarized beam in the RHIC Run-2013 and Run-2015. High beam current, brightness, and polarization resulted in 75% polarization at 23 GeV out of Alternating Gradient Synchrotron (AGS) and 60%-65% beam polarization at 100-250 GeV colliding beams in RHIC.

  1. Numerical Simulation Multicomponent Ion Beam Transport form ECR Ion Source

    Institute of Scientific and Technical Information of China (English)

    MaLei; SongMingtao; ZhangZimin; CaoYun

    2003-01-01

    In order to simulate the transport of multi-components ion beam extracted from an ECR ion source, we have developed a multi-charged ion beam transport program named MCIBS 1.0. The program is dedicated to numerical simulation of the behavior of highly-charged ion beam and optimization of beam optics in transport lines and is realized on a PC with Windows user interface of Microsoft Visual Basic. Among all the ions with different charge states in the beam, the exchanges of electrons between highly charged ions and low charged ions or neutral,atoms of residual gas are taken into account by using classical Molecular Over-barrier Model and Monte Carlo method. An advanced Windows graphical interface makes it; comfortable and friendly for the user to operate in an interactive mode. The present program is used for the numerical calculation and optimization of beam optics in a transport line consisting of various magnetic elements, such as dipole magnet, quadrupole and so on. It is possible to simultaneously simulate 200,000 particles, in a transport line of 340 m at most, and show every particle orbit. Beam cross section graphics and emittance phase pictures can be also shown at any position in the transport line.

  2. Low energy ion beam dynamics of NANOGAN ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sarvesh, E-mail: sarvesh@iuac.res.in; Mandal, A.

    2016-04-01

    A new low energy ion beam facility (LEIBF) has been developed for providing the mass analyzed highly charged intense ion beams of energy ranging from a few tens of keV to a few MeV for atomic, molecular and materials sciences research. The new facility consists of an all permanent magnet 10 GHz electron cyclotron resonance (ECR) ion source (NANOGAN) installed on a high voltage platform (400 kV) which provides large currents of multiply charged ion beams. Higher emittance at low energy of intense ion beam puts a tremendous challenge to the beam optical design of this facility. The beam line consists of mainly the electrostatic quadrupoles, an accelerating section, analyzing cum switching magnet and suitable beam diagnostics including vacuum components. The accelerated ion beam is analyzed for a particular mass to charge (m/q) ratio as well as guided to three different lines along 75°, 90° and 105° using a large acceptance analyzing cum switching magnet. The details of transverse beam optics to all the beam lines with TRANSPORT and GICOSY beam optics codes are being described. Field computation code, OPERA 3D has been utilized to design the magnets and electrostatic quadrupoles. A theoretical estimation of emittance for optimized geometry of ion source is given so as to form the basis of beam optics calculations. The method of quadrupole scan of the beam is used to characterize the emittance of the final beam on the target. The measured beam emittance increases with m/q ratios of various ion beams similar to the trend observed theoretically.

  3. Negative Ion Sources: Magnetron and Penning

    CERN Document Server

    Faircloth, D C

    2013-01-01

    The history of the magnetron and Penning electrode geometry is briefly outlined. Plasma generation by electrical discharge-driven electron impact ionization is described and the basic physics of plasma and electrodes relevant to magnetron and Penning discharges are explained. Negative ions and their applications are introduced, along with their production mechanisms. Caesium and surface production of negative ions are detailed. Technical details of how to build magnetron and Penning surface plasma sources are given, along with examples of specific sources from around the world. Failure modes are listed and lifetimes compared.

  4. Recent negative ion source activity at JYFL

    Science.gov (United States)

    Kalvas, T.; Tarvainen, O.; Komppula, J.; Laitinen, M.; Sajavaara, T.; Koivisto, H.; Jokinen, A.; Dehnel, M. P.

    2013-02-01

    A filament-powered multicusp ion source for production of H- has been developed for the Jyväskylä Pelletron accelerator for use in ion beam lithography and particle induced X-ray emission applications. The source can be considered conventional with the exception of the filter field being created with an electric magnet for continuous adjustability. A permanent magnet dipoleantidipole electron dump is integrated in the puller electrode. The source provides 50 μA H- beam at 10 keV energy with 0.019 mm mrad 95 % normalized rms emittance through a 2 mm aperture. Lower emittance is achievable by changing the plasma electrode insert to a smaller aperture one if application requires. A new commercial MCC30/15 cyclotron has been installed at the Jyväskylä accelerator laboratory providing 30MeV H+ and 15Mev D+ for use in nuclear physics experiments and applications. The ion source delivered with the cyclotron is a a filament-powered multicusp source capable of about 130 h continuous operation at 1 mA H- output between filament changes. The ion source is located in the cyclotron vault and therefore a significant waiting time for the vault cooldown is required before filament change is possible. This kind of operation is not acceptable as 350 h and longer experiments are expected. Therefore a project for developing a CW 13.56 MHz RF ion source has been initiated. A planar RF antenna replacing the filament back plate of the existing TRIUMF-type ion source has been used in the first tests with 240 μA of H- and 21 mA of electrons measured at 1.5 kW of RF power. Tests with higher RF power levels were prevented by electron beam induced sparking. A new plasma chamber has been built and a new extraction is being designed for the RF ion source. The extraction code IBSimu has recently gone through a major update on how smooth electrode surfaces are implemented in the Poisson solvers. This has made it possible to implement a fast multigrid solver with low memory consumption. Also

  5. rf improvements for Spallation Neutron Source H-ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yoon W [ORNL; Fuja, Raymond E [ORNL; Goulding, Richard Howell [ORNL; Hardek, Thomas W [ORNL; Lee, Sung-Woo [ORNL; McCarthy, Mike [ORNL; Piller, Chip [ORNL; Shin, Ki [ORNL; Stockli, Martin P [ORNL; Welton, Robert F [ORNL

    2010-01-01

    The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering 38 mA H beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride AlN plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier. 2010 American Institute of Physics.

  6. Development of laser ion source for heavy ion applications

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Shinji, E-mail: shibuya@aec-beam.co.jp [Accelerator Engineering Corporation, 3-8-5 Konakadai, Inage-ku, Chiba 263-0043 (Japan); Hattori, Toshiyuki, E-mail: thattori@nr.titech.ac.jp [Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan); Hayashizaki, Noriyosu, E-mail: nhayashi@nr.titech.ac.jp [Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550 (Japan); Kashiwagi, Hirotsugu, E-mail: hirotsugu.kashiwagi@jaea.go.jp [Japan Atomic Energy Agency, 1233 Watanuki-machi, Takasaki-shi, Gunma 370-1292 (Japan); Maruyama, Toshiyuki, E-mail: t-maruyama@toyama-jp.com [Toyama Co., Ltd., 4-13-16 Hibarigaoka, Zama-shi, Kanagawa 252-0003 (Japan); Mochizuki, Tetsuro, E-mail: Mochizuki@toyama-jp.com [Toyama Co., Ltd., 4-13-16 Hibarigaoka, Zama-shi, Kanagawa 252-0003 (Japan); Momota, Sadao, E-mail: momota.sadao@kochi-tech.ac.jp [Kochi University of Technology, 185 Tosa-yamada-cyo, Kami-shi, Kochi 782-8502 (Japan); Nakagawa, Jun, E-mail: nakagawa@toyama-jp.com [Toyama Co., Ltd., 4-13-16 Hibarigaoka, Zama-shi, Kanagawa 252-0003 (Japan); Takeuchi, Takeshi, E-mail: aec2g@nirs.go.jp [Accelerator Engineering Corporation, 3-8-5 Konakadai, Inage-ku, Chiba 263-0043 (Japan)

    2011-12-15

    We have been developing a high-performance laser ion source (LIS) for practical applications since 2009. Ideally, the LIS should generate a carbon beam with a peak current of 20 mA and a pulse duration of over 1 {mu}s. We selected a Nd:YAG laser with a Gaussian-coupled resonator as the laser source based on our experience of generating high-charge-state ion beams. This laser can produce fundamental pulses with a power of 650 mJ and durations of about 6 ns. The graphite target used is 10 cm high and 10 cm in diameter, as it can be irradiated with up to 10{sup 5} laser shots. The maximum extraction voltage was designed to be 50 kV. We have already finished designing the LIS and we commenced fabrication. We intend to measure the source performance by performing plasma and beam tests up to the end of March 2011.

  7. A new approach to endocochlear potential and potassium ion concentration measures in mini pig models

    Institute of Scientific and Technical Information of China (English)

    Lili Ren a; Ling Zhang b; Weiwei Guo a; Wei Sun c; Shiming Yang a

    2014-01-01

    Mini pig models are large mammals and their ears are more similar with human beings in structure and development than other animals. However, the study on porcine ears is still in the initial stage and there is no description of an ideal operation approach to endocochlear potential and potassium ion concentration measurements. In this article, we describe a pre-auricular surgical approach to access the middle and inner ear for endocochlear potential and potassium ion concentration measures in mini pig models. Ten one-week old normal mini pigs were used in the study. The bulla of the temporal bone was accessed via a pre-auricular approach for endocochlear potential and potassium ion concentration measurements. The condition of the animals during the first posteexperiment 24 h was observed. One animal died during surgery. The pre-auricular approach improved protection and preservation of relevant nervous and vascular elements including the facial nerve and carotid ar-tery. So, the pre-auricular approach can be used for endocochlear potential and potassium ion concentration measurements with improved nerve and artery preservation mini pigs.

  8. Development of versatile multiaperture negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Cavenago, M.; Minarello, A.; Sattin, M. [INFN-LNL, v.le dell' Universita n 2, I-35020, Legnaro (PD) Italy (Italy); Serianni, G.; Antoni, V.; Bigi, M.; Pasqualotto, R.; Recchia, M.; Veltri, P.; Agostinetti, P.; Barbisan, M.; Baseggio, L.; Cervaro, V.; Degli Agostini, F.; Franchin, L.; Laterza, B.; Ravarotto, D.; Rossetto, F.; Zaniol, B.; Zucchetti, S. [Consorzio RFX, Associazione Euratom-ENEA sulla fusione, c.so S. Uniti 4, 35127 Padova (Italy); and others

    2015-04-08

    Enhancement of negative ion sources for production of large ion beams is a very active research field nowadays, driven from demand of plasma heating in nuclear fusion devices and accelerator applications. As a versatile test bench, the ion source NIO1 (Negative Ion Optimization 1) is being commissioned by Consorzio RFX and INFN. The nominal beam current of 135 mA at −60 kV is divided into 9 beamlets, with multiaperture extraction electrodes. The plasma is sustained by a 2 MHz radiofrequency power supply, with a standard matching box. A High Voltage Deck (HVD) placed inside the lead shielding surrounding NIO1 contains the radiofrequency generator, the gas control, electronics and power supplies for the ion source. An autonomous closed circuit water cooling system was installed for the whole system, with a branch towards the HVD, using carefully optimized helical tubing. Insulation transformer is installed in a nearby box. Tests of several magnetic configurations can be performed. Status of experiments, measured spectra and plasma luminosity are described. Upgrades of magnetic filter, beam calorimeter and extraction grid and related theoretical issues are reviewed.

  9. Development of versatile multiaperture negative ion sources

    Science.gov (United States)

    Cavenago, M.; Serianni, G.; Antoni, V.; Bigi, M.; De Muri, M.; Pasqualotto, R.; Recchia, M.; Veltri, P.; Agostinetti, P.; Barbisan, M.; Baseggio, L.; Cervaro, V.; Cazzador, M.; Degli Agostini, F.; Franchin, L.; Kulevoy, T.; Laterza, B.; Mimo, A.; Minarello, A.; Petrenko, S.; Ravarotto, D.; Rossetto, F.; Sattin, M.; Zaniol, B.; Zucchetti, S.

    2015-04-01

    Enhancement of negative ion sources for production of large ion beams is a very active research field nowadays, driven from demand of plasma heating in nuclear fusion devices and accelerator applications. As a versatile test bench, the ion source NIO1 (Negative Ion Optimization 1) is being commissioned by Consorzio RFX and INFN. The nominal beam current of 135 mA at -60 kV is divided into 9 beamlets, with multiaperture extraction electrodes. The plasma is sustained by a 2 MHz radiofrequency power supply, with a standard matching box. A High Voltage Deck (HVD) placed inside the lead shielding surrounding NIO1 contains the radiofrequency generator, the gas control, electronics and power supplies for the ion source. An autonomous closed circuit water cooling system was installed for the whole system, with a branch towards the HVD, using carefully optimized helical tubing. Insulation transformer is installed in a nearby box. Tests of several magnetic configurations can be performed. Status of experiments, measured spectra and plasma luminosity are described. Upgrades of magnetic filter, beam calorimeter and extraction grid and related theoretical issues are reviewed.

  10. Design of Magnetic Field System for Calutron Ion Source Set

    Institute of Scientific and Technical Information of China (English)

    REN; Xiu-yan; ZENG; Zi-qiang

    2013-01-01

    The Calutron ion source is the most important equipment of EMIS,and the structure of the ion source is more complicated.Because the parameter of each part is interrelate,as experiment and test set,It is very convenient to adjust the parameter of ion source and make the ion source get a good quality.Magnetic field system is the leading and necessary auxiliary equipment of the Calutron ion source

  11. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    P Kumar; G Rodrigues; U K Rao; C P Safvan; D Kanjilal; A Roy

    2002-11-01

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion beams ranging from a few keV to a few MeV for research in materials sciences, atomic and molecular physics is described. One of the important features of this facility is the availability of relatively large currents of multiply charged positive ions from an electron cyclotron resonance (ECR) source placed entirely on a high voltage platform. All the electronic and vacuum systems related to the ECR source including 10 GHz ultra high frequency (UHF) transmitter, high voltage power supplies for extractor and Einzel lens are placed on a high voltage platform. All the equipments are controlled using a personal computer at ground potential through optical fibers for high voltage isolation. Some of the experimental facilities available are also described.

  12. Effects of dietary pH and phosphorus source on performance, gastrointestinal tract digesta, and bone measurements of weanling pigs.

    Science.gov (United States)

    Straw, M L; Kornegay, E T; Evans, J L; Wood, C M

    1991-11-01

    Crossbred pigs (n = 144, average age and weight = 28 +/- 3 d, 7.5 kg) were used in two 6-wk trials to assess the effects of dietary pH and P source on growth performance, gastrointestinal digesta pH and chloride ion concentration (Cl-), and bone characteristics. Treatments were randomly allotted within blocks (based on weight within gender) to a 3 x 2 factorial arrangement with three dietary pH levels (5.4, 6.0, and 6.7) and two P sources: dicalcium phosphate (DCP) and defluorinated phosphate (DFP). Pigs fed the pH 6.7 diet had reduced ADG (P less than .01) and average daily feed intakes (ADFI; P less than .001) during wk 1 to 3 and overall compared with pigs fed the pH 6.0 diet, but ADG and ADFI were not affected when the pH 5.4 diet was fed. There was a dietary pH x P source interaction (P less than .05) for ADFI. Pigs had decreased ADFI as dietary pH was increased from 6.0 to 6.7 for both DCP and DFP, but ADFI was similar for the pH 6.0 and 5.4 diets with DFP, whereas ADFI was greater for the pH 5.4 diet with DCP. Dietary pH did not influence ADFI:ADG ratio (F:G; P greater than .05), and P source had no effect (P greater than .05) on either ADG, ADFI, or F:G.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Main magnetic focus ion source with the radial extraction of ions

    CERN Document Server

    Ovsyannikov, V P

    2015-01-01

    In the main magnetic focus ion source, atomic ions are produced in the local ion trap created by the rippled electron beam in focusing magnetic field. Here we present the novel modification of the room-temperature hand-size device, which allows the extraction of ions in the radial direction perpendicular to the electron beam across the magnetic field. The detected X-ray emission evidences the production of Ir$^{44+}$ and Ar$^{16+}$ ions. The ion source can operate as the ion trap for X-ray spectroscopy, as the ion source for the production of highly charged ions and also as the ion source of high brightness.

  14. The SNS External Antenna H- Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Welton, Robert F [ORNL; Stockli, Martin P [ORNL; Murray Jr, S N [ORNL; Crisp, Danny W [ORNL; Carmichael, Justin R [ORNL; Goulding, Richard Howell [ORNL; Han, Baoxi [ORNL; Pennisi, Terry R [ORNL; Santana, Manuel [ORNL

    2010-01-01

    The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that we will meet our operational commitments as well as provide for future facility upgrades with high reliability, we have developed an RF-driven, H- ion source based on a ceramic aluminum nitride (AlN) plasma chamber [1]. This source is expected to be utilized by the SNS for neutron production starting in 2009. This report details the design of the production source which features an AlN plasma chamber, 2-layer external antenna, cooled-multicusp magnet array, Cs2CrO4 cesium system and a Molybdenum plasma ignition gun. Performance of the production source both on the SNS accelerator and SNS test stand is reported. The source has also been designed to accommodate an elemental Cs system with an external reservoir which has demonstrated unanalyzed beam currents up to ~100mA (60Hz, 1ms) on the SNS ion source test stand.

  15. Ion source choices - an h- source for the high intensity neutrino source

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, Douglas P.; /Fermilab; Welton, Robert F.; /SNS Project, Oak Ridge; Stockli, Martin P.; Peters, Jens; /DESY; Alessi, James; /Brookhaven

    2006-08-01

    The High Intensity Neutrino Source (HINS) program at Fermilab (formerly the Proton Driver) aims to develop a multi-mission linear accelerator (LINAC) capable of accelerate H{sup -} ions to 8 GeV. This paper touches on the ion source requirements for the HINS and discusses long pulse length testing of three ion sources which appear to have the capability of meeting these requirements.

  16. Status of ECR ion sources at JAERI

    CERN Document Server

    Yokota, W; Nara, T; Ishi, Y; Arakawa, K; Ohkoshi, K

    1999-01-01

    At the Takasaki site of Japan Atomic Energy Research Institute, four ECR ion sources were purchased or developed so far. This paper will report their performance, modification and status. The outlines for each source are as follows; 1. OCTOPUS purchased from IBA s.a. has been in use with a cyclotron since 1990. The gas feed system was modified to change gas species within 10 minutes to avoid impurity ions in the cocktail beam acceleration technique of the cyclotron. 2. ECR-18 with 18-GHz microwave has a solenoid coil between a pair of mirror coils to change mirror ratio in a wide range. A bump between mirror peaks in the original axial field distribution was removed by halving the solenoid length. The performance in generating high charge state ions was significantly improved as a result. 3. HYPERNANOGAN was purchased from PANTECHNIK s.a. and installed in the cyclotron system this year. Test operation was successfully made with generation of Ar, Pb and Ta ions. 4. MINI ECR is a full permanent magnet source wi...

  17. A high charge state multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; Keller, R. (Accelerator and Fusion Research Division, Lawrence Berkeley Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (US))

    1990-01-01

    Attempts have been made to generate high charge state ion beams by employing a multicusp plasma source. Three experimental investigations have been performed at Lawrence Berkeley Laboratory (LBL) and at Gesellschaft fuer Schwerionenforschung, Darmstadt (GSI) to study the charge state distributions and the emittance of the extracted beam. Results demonstrate that charge state as high as +7 can be obtained with argon or xenon plasmas. The brightness of a 11-mA xenon ion beam is found to be 26 A/({pi} mm mrad){sup 2}.

  18. Compact microwave ion source for industrial applications.

    Science.gov (United States)

    Cho, Yong-Sub; Kim, Dae-Il; Kim, Han-Sung; Seol, Kyung-Tae; Kwon, Hyeok-Jung; Hong, In-Seok

    2012-02-01

    A 2.45 GHz microwave ion source for ion implanters has many good properties for industrial application, such as easy maintenance and long lifetime, and it should be compact for budget and space. But, it has a dc current supply for the solenoid and a rf generator for plasma generation. Usually, they are located on high voltage platform because they are electrically connected with beam extraction power supply. Using permanent magnet solenoid and multi-layer dc break, high voltage deck and high voltage isolation transformer can be eliminated, and the dose rate on targets can be controlled by pulse duty control with semiconductor high voltage switch. Because the beam optics does not change, beam transfer components, such as focusing elements and beam shutter, can be eliminated. It has shown the good performances in budget and space for industrial applications of ion beams.

  19. Growth and intestinal morphology of pigs from sows fed two zinc sources during gestation and lactation.

    Science.gov (United States)

    Payne, R L; Bidner, T D; Fakler, T M; Southern, L L

    2006-08-01

    An experiment was conducted to compare the effects of organic (Zn AA complex, ZnAA) and inorganic Zn (ZnSO4) sources on sows and their progeny during gestation and lactation and on the pigs during the nursery period. The dietary treatments were 1) a corn-soybean meal diet with 100 ppm Zn from ZnSO4 (control); 2) diet 1 + 100 ppm additional Zn from ZnSO4; and 3) diet 1 + 100 ppm additional Zn from ZnAA. Dietary additions were on an as-fed basis. Thirty-one primaparous and multiparous sows were allotted to the treatment diet beginning on d 15 of gestation and continuing through lactation. At weaning (d 17 of age), 202 pigs (63, 55, and 84 pigs for treatments 1 to 3, respectively) were allotted to the same dietary treatment as their dam. The pigs were fed a 3-phase diet regimen during the nursery period: d 0 to 7 (phase I); d 7 to 21 (phase II); and d 21 to 28 (phase III). At weaning and at the end of phase III, 1 gilt per replicate was killed, and the left front foot, liver, pancreas, and entire small intestine were removed. Diet had no effect (P > 0.10) on any response during gestation. During lactation, there was an increase (P pigs (P pigs (P pigs from sows fed ZnSO4 was increased (P 0.10) by diet. Pigs fed ZnSO4 had greater duodenal villus width (P pigs fed ZnSO4 or the control diet had greater ileal villus width (P Pigs fed ZnSO4 or ZnAA had more (P pigs fed ZnSO4, followed by those fed ZnAA, and then by those fed the control diet (P pigs fed ZnSO4 compared with those fed the control diet. These results suggest that 100 ppm Zn in trace mineral premixes provides adequate Zn for optimal growth performance of nursery pigs, but that 100 ppm additional Zn from ZnAA in sow diets may increase pigs born and weaned per litter.

  20. Field ion source development for neutron generators

    Science.gov (United States)

    Bargsten Johnson, B.; Schwoebel, P. R.; Holland, C. E.; Resnick, P. J.; Hertz, K. L.; Chichester, D. L.

    2012-01-01

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption (˜20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with ˜10,000 tip arrays have achieved deuterium ion currents of ˜50 nA. Neutron production by field ionization has yielded ˜10 2 n/s from ˜1 mm 2 of array area using the deuterium-deuterium fusion reaction at 90 kV.

  1. Field ion source development for neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    Bargsten Johnson, B. [University of New Mexico, Albuquerque, NM 87131 (United States); Schwoebel, P.R., E-mail: schwoebel@chtm.unm.edu [University of New Mexico, Albuquerque, NM 87131 (United States); Holland, C.E. [SRI International, Menlo Park, CA 94025 (United States); Resnick, P.J. [Sandia National Laboratories, Albuquerque, NM 87123 (United States); Hertz, K.L. [Sandia National Laboratories, Livermore, CA 94551 (United States); Chichester, D.L. [Idaho National Laboratory, Idaho Falls, ID 83415 (United States)

    2012-01-21

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

  2. Field Ion Source Development for Neutron Generators

    Energy Technology Data Exchange (ETDEWEB)

    B. Bargsten Johnson; P. R. Schwoebel; C. E. Holland; P. J. Resnick; K. L. Hertz; D. L. Chichester

    2012-01-01

    An ion source based on the principles of electrostatic field desorption is being developed to improve the performance of existing compact neutron generators. The ion source is an array of gated metal tips derived from field electron emitter array microfabrication technology. A comprehensive summary of development and experimental activities is presented. Many structural modifications to the arrays have been incorporated to achieve higher tip operating fields, while lowering fields at the gate electrode to prevent gate field electron emission which initiates electrical breakdown in the array. The latest focus of fabrication activities has been on rounding the gate electrode edge and surrounding the gate electrode with dielectric material. Array testing results have indicated a steady progression of increased array tip operating fields with each new design tested. The latest arrays have consistently achieved fields beyond those required for the onset of deuterium desorption ({approx}20 V/nm), and have demonstrated the desorption of deuterium at fields up to 36 V/nm. The number of ions desorbed from an array has been quantified, and field desorption of metal tip substrate material from array tips has been observed for the first time. Gas-phase field ionization studies with {approx}10,000 tip arrays have achieved deuterium ion currents of {approx}50 nA. Neutron production by field ionization has yielded {approx}10{sup 2} n/s from {approx}1 mm{sup 2} of array area using the deuterium-deuterium fusion reaction at 90 kV.

  3. Indigenous Ion Sources for Material Processing

    Directory of Open Access Journals (Sweden)

    R. Bhattacharyya

    2009-07-01

    Full Text Available Ion beam sources for material processing in their working are no different from those required for space thrusters, ion implanters or for fusion experiments. They are scaled down versions of the devices earlier developed for space research. However, they are not being manufactured in the country. Their use in ophthalmic coatings and DLC for magnetic heads, CD, etc. are commercially attractive. In this technical report is suggested as to a strategy how to develop them, pooling resources from different active groups in the country, with specific targets. Dc gridded,Rf gridded, Saddle field, End Hall and ICP sources have been identified based on preliminary work carried out at different places in the country. This areas may be read more as a research opportunity report.Defence Science Journal, 2009, 59(4, pp.377-394, DOI:http://dx.doi.org/10.14429/dsj.59.1537

  4. Microscopy with a Deterministic Single Ion Source

    CERN Document Server

    Jacob, Georg; Wolf, Sebastian; Ulm, Stefan; Couturier, Luc; Dawkins, Samuel T; Poschinger, Ulrich G; Schmidt-Kaler, Ferdinand; Singer, Kilian

    2015-01-01

    We realize a single particle microscope by using deterministically extracted laser cooled $^{40}$Ca$^+$ ions from a Paul trap as probe particles for transmission imaging. We demonstrate focusing of the ions with a resolution of 5.8$\\;\\pm\\;$1.0$\\,$nm and a minimum two-sample deviation of the beam position of 1.5$\\,$nm in the focal plane. The deterministic source, even when used in combination with an imperfect detector, gives rise to much higher signal to noise ratios as compared with conventional Poissonian sources. Gating of the detector signal by the extraction event suppresses dark counts by 6 orders of magnitude. We implement a Bayes experimental design approach to microscopy in order to maximize the gain in spatial information. We demonstrate this method by determining the position of a 1$\\,\\mu$m circular hole structure to an accuracy of 2.7$\\,$nm using only 579 probe particles.

  5. CAS Accelerator Physics (Ion Sources) in Slovakia

    CERN Multimedia

    CAS School

    2012-01-01

    The CERN Accelerator School (CAS) and the Slovak University of Technology jointly organised a specialised course on ion sources, held at the Hotel Senec, Senec, Slovakia, from 29 May to 8 June, 2012.   Following some background lectures on accelerator physics and the fundamental processes of atomic and plasma physics, the course covered a wide range of topics related to ion sources and highlighted the latest developments in the field. Realistic case studies and topical seminars completed the programme. The school was very successful, with 69 participants representing 25 nationalities. Feedback from the participants was extremely positive, reflecting the high standard of the lectures. The case studies were performed with great enthusiasm and produced some excellent results. In addition to the academic programme, the participants were able to take part in a one-day excursion consisting of a guided tour of Bratislava and free time. A welcome event was held at the Hotel Senec, with s...

  6. Improved Ambient Pressure Pyroelectric Ion Source

    Science.gov (United States)

    Beegle, Luther W.; Kim, Hugh I.; Kanik, Isik; Ryu, Ernest K.; Beckett, Brett

    2011-01-01

    The detection of volatile vapors of unknown species in a complex field environment is required in many different applications. Mass spectroscopic techniques require subsystems including an ionization unit and sample transport mechanism. All of these subsystems must have low mass, small volume, low power, and be rugged. A volatile molecular detector, an ambient pressure pyroelectric ion source (APPIS) that met these requirements, was recently reported by Caltech researchers to be used in in situ environments.

  7. Heavy Ion Injection Into Synchrotrons, Based On Electron String Ion Sources

    CERN Document Server

    Donets, E E; Syresin, E M

    2004-01-01

    A possibility of heavy ions injection into synchrotrons is discussed on the base of two novel ion sources, which are under development JINR during last decade: 1) the electron string ion source (ESIS), which is a modified version of a conventional electron beam ion source (EBIS), working in a reflex mode of operation, and 2) the tubular electron string ion source (TESIS). The Electron String Ion Source "Krion-2" (VBLHE, JINR, Dubna) with an applied confining magnetic field of 3 T was used for injection into the superconducting JINR synchrotron - Nuclotron and during this runs the source provided a high pulse intensity of the highly charged ion beams: Ar16+

  8. Development of a compact powdery sample negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Motoi [Doshisha Univ., Tanabe, Kyoto (Japan). Faculty of Engineering; Sasao, Mamiko; Kawano, Hiroyuki

    1997-02-01

    A gas-feed-free compact negative ion source can be realized by utilizing the process of electron stimulated desorption from powdery sample. A negative ion source of this type is designed to be attached to a standard 1.33 inch copper-gasket-flange. The ion source is operated stable with LiH powder for more than 10 hours with the mass-separated negative hydrogen ion current of 1 nA. The source causes minute gas emission, and particularly suitable for ion beam applications in which a good vacuum is required. The present status of the compact ion source development is briefly described. (author)

  9. Development of the RF Ion Sources for Focused Ion Beam Accelerators

    Directory of Open Access Journals (Sweden)

    V. Voznyi

    2014-01-01

    Full Text Available The paper presents the results of investigations of ion sources developed in the IAP of NAS of Ukraine for generation of high brightness ion beams with small energy spread. A series of RF ion sources operated at the frequency of 27.12 MHz were studied: the inductive RF ion source, the helicon ion source, the multi-cusp RF ion source, and the sputter type RF source of metal ions. A global model and transformer model were applied for calculation of RF source plasma parameters. Ion energy spread, ion mass, and ion current density of some sources were measured in the wide range of RF power, extraction voltage and gas pres-sure.

  10. Negative chlorine ions from multicusp radio frequency ion source for heavy ion fusion applications

    Science.gov (United States)

    Hahto, S. K.; Hahto, S. T.; Kwan, J. W.; Leung, K. N.; Grisham, L. R.

    2003-06-01

    Use of high mass atomic neutral beams produced from negative ions as drivers for inertial confinement fusion has been suggested recently. Best candidates for the negative ions would be bromine and iodine with sufficiently high mass and electron affinity. These materials require a heated vapor ion source. Chlorine was selected for initial testing because it has similar electron affinity to those of bromine and iodine, and is available in gaseous form. An experiment was set up by the Plasma and Ion Source Technology Group in Lawrence Berkeley National Laboratory to measure achievable current densities and other beam parameters by using a rf driven multicusp ion source [K. N. Leung, Rev. Sci. Instrum. 65, 1165 (1994); Q. Ji et al., Rev. Sci. Instrum. 73, 822 (2002)]. Current density of 45 mA/cm2 was achieved with 99.5% of the beam as atomic negative chlorine at 2.2 kW of rf power. An electron to negative ion ratio as low as 7 to 1 was observed, while the ratio of positive and negative chlorine ion currents was 1.3. This in addition to the fact that the front plate biasing had almost no effect to the negative chlorine ion and electron currents indicates that a very high percentage of the negative charge in the extraction area of the ion source was in form of Cl- ions. A comparison of positive and negative chlorine ion temperatures was conducted with the pepper pot emittance measurement technique and very similar transverse temperature values were obtained for positive and negative chlorine ions.

  11. Polarized ion source development at IUCF

    Energy Technology Data Exchange (ETDEWEB)

    Derenchuk, V.; Brown, R.; Wedekind, M. (Indiana University Cyclotron Facility, Bloomington, Indiana 47408 (United States))

    1993-12-05

    The IUCF high intensity polarized ion source (HIPIOS) has been completed and installed in the 600 kV terminal. The design was originally based on the source in operation at TUNL, which employs cold ([similar to]30 K) atomic beam technology and an electron cyclotron resonance ionizer. Development of the reliability and intensity of the atomic beam source will be described. An atomic beam flux of 5.0[times]10[sup 16] atoms/sec is estimated to be incident on the ECR ionizer. Preliminary testing of a multiple grid, high conductance, extraction system on the ECR ionizer has resulted in an extracted current of 500 [mu]A attributable to the atomic beam, as measured 30 cm downstream of the ECR ionizer. After a mass analysis magnet, 245 [mu]A are measured with a normalized emittance of 0.78 [pi]-mm-mrad.

  12. Negative ion production in multicusp sources (abstract)

    Science.gov (United States)

    Belchenko, Y. I.; Oka, Y.; Kaneko, O.; Takeiri, Y.; Tsumori, K.

    2002-02-01

    Cesium seed improves multicusp negative ion (NI) Source performance. Experiments display the surface origin of NI production in the multicusp source (MS): a strong NI yield dependence on plasma grid (PG) temperature and work function, a low NI yield sensitivity to Cs density in plasma, etc. On other hand, cesium seed changes the MS plasma potential, electron density, and temperature, decreases the coextracted electron current, and produces a NI density increase in the source volume. Cesium ions can contribute to the slow positive charge in the plasma presheath and extraction region, and improve the NI extraction. The study of NI production was done by the directed deposition of a well-defined amount of cesium, by cesium recovery in the MS. The obtained data evidences the surface origin of H- yield enhancement 3-10 mg cesium deposition was enough for producing a NI yield increase due to hydrogen conversion on the cesiated PG surface. The long-term H- yield enhancement with larger cesium deposition and no change of NI yield with the PG temperature change displays the maintenance of the thick Cs+W coverage, which governs the enhanced surface H- production in the MS. The experimental data and the MS surface-plasma mechanism features will be presented and discussed.

  13. Application of ECR ion source beams in atomic physics

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, F.W.

    1987-01-01

    The availability of intense, high charge state ion beams from ECR ion sources has had significant impact not only on the upgrading of cyclotron and synchrotron facilities, but also on multicharged ion collision research, as evidenced by the increasing number of ECR source facilities used at least on a part time basis for atomic physics research. In this paper one such facility, located at the ORNL ECR source, and dedicated full time to the study of multicharged ion collisions, is described. Examples of applications of ECR ion source beams are given, based on multicharged ion collision physics studies performed at Oak Ridge over the last few years. 21 refs., 18 figs., 2 tabs.

  14. MIVOC method at the mVINIS ion source

    Directory of Open Access Journals (Sweden)

    Jovović Jovica

    2007-01-01

    Full Text Available Based on the metal-ions-from-volatile-compounds (MIVOC method with the mVINIS ion source, we have produced multiply charged ion beams from solid substances. Highly in tense, stable multiply charged ion beams of several solid substances with high melting points were extracted by using this method. The spectrum of multiply charged ion beams obtained from the element hafnium is presented here. For the first time ever, hafnium ion beam spectra were recorded at an electron cyclotron resonance ion source. Multiply charged ion beams from solid substances were used to irradiate the polymer, fullerene and glassy carbon samples at the channel for the modification of materials.

  15. A hollow cathode ion source for production of primary ions for the BNL electron beam ion source.

    Science.gov (United States)

    Alessi, James; Beebe, Edward; Carlson, Charles; McCafferty, Daniel; Pikin, Alexander; Ritter, John

    2014-02-01

    A hollow cathode ion source, based on one developed at Saclay, has been modified significantly and used for several years to produce all primary 1+ ions injected into the Relativistic Heavy Ion Collider Electron Beam Ion Source (EBIS) at Brookhaven. Currents of tens to hundreds of microamperes have been produced for 1+ ions of He, C, O, Ne, Si, Ar, Ti, Fe, Cu, Kr, Xe, Ta, Au, and U. The source is very simple, relying on a glow discharge using a noble gas, between anode and a solid cathode containing the desired species. Ions of both the working gas and ionized sputtered cathode material are extracted, and then the desired species is selected using an ExB filter before being transported into the EBIS trap for charge breeding. The source operates pulsed with long life and excellent stability for most species. Reliable ignition of the discharge at low gas pressure is facilitated by the use of capacitive coupling from a simple toy plasma globe. The source design, and operating experience for the various species, is presented.

  16. A hollow cathode ion source for production of primary ions for the BNL electron beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, James, E-mail: alessi@bnl.gov; Beebe, Edward; Carlson, Charles; McCafferty, Daniel; Pikin, Alexander; Ritter, John [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2014-02-15

    A hollow cathode ion source, based on one developed at Saclay, has been modified significantly and used for several years to produce all primary 1+ ions injected into the Relativistic Heavy Ion Collider Electron Beam Ion Source (EBIS) at Brookhaven. Currents of tens to hundreds of microamperes have been produced for 1+ ions of He, C, O, Ne, Si, Ar, Ti, Fe, Cu, Kr, Xe, Ta, Au, and U. The source is very simple, relying on a glow discharge using a noble gas, between anode and a solid cathode containing the desired species. Ions of both the working gas and ionized sputtered cathode material are extracted, and then the desired species is selected using an ExB filter before being transported into the EBIS trap for charge breeding. The source operates pulsed with long life and excellent stability for most species. Reliable ignition of the discharge at low gas pressure is facilitated by the use of capacitive coupling from a simple toy plasma globe. The source design, and operating experience for the various species, is presented.

  17. Ion sources for high-power hadron accelerators

    CERN Document Server

    Faircloth, Dan

    2013-01-01

    Ion sources are a critical component of all particle accelerators. They create the initial beam that is accelerated by the rest of the machine. This paper will introduce the many methods of creating a beam for high-power hadron accelerators. A brief introduction to some of the relevant concepts of plasma physics and beam formation is given. The different types of ion source used in accelerators today are examined. Positive ion sources for producing H+ ions and multiply charged heavy ions are covered. The physical principles involved with negative ion production are outlined and different types of negative ion sources are described. Cutting edge ion source technology and the techniques used to develop sources for the next generation of accelerators are discussed.

  18. Characteristics of the Berkeley multicusp ion source.

    Science.gov (United States)

    Ehlers, K W; Leung, K N

    1979-11-01

    The performance of a cubical permanent magnet generated line-cusp ion source has been investigated for use with neutral beam injectors. This source has been operated with discharge currents greater than 500 A and ion current densities higher than 400 mA/cm2 at the extraction grid. The uniformity of the density profile across the extraction area is found to be dependent on the gas pressure. By using a fast Langmuir probe sweeping circuit, the electron temperature and the plasma density and potential have been analyzed for different discharge powers and gas pressures. The heat load on the plasma grid when it is electrically floating or connected to the negative cathode has been compared calorimetrically. The use of lanthanum hexaboride and impregnated oxide cathodes have been investigated for the purpose of long pulse operation. The phenomenon of mode flipping is found to occur quite frequently during a discharge with these magnetic-field-free cathodes. Species composition as a function of discharge power and chamber length is measured by a mass spectrometer.

  19. Negative ion production in multicusp sources

    Science.gov (United States)

    Belchenko, Yu. I.; Oka, Y.; Kaneko, O.; Takeiri, Y.; Tsumori, K.

    2002-04-01

    The study of negative ion production in the multicusp negative ion sources (MS) was done by the directed deposition of well-defined amount of cesium into MS, by the cesium recovery from the polluted layers in the MS and by the plasma grid masking. The data obtained evidences the surface-plasma mechanism of negative ion production in the MS. It is shown that a dynamic cesium-tungsten coverage on a plasma grid surface provides the enhanced H- production in the MS. The Cs+W coverage is produced on the hot plasma grid surface due to coadsorption of cesium and of tungsten, evaporated from filaments. The permanent flux of cesium to plasma grid coverage is produced by the thick Cs+W reservoir with a high (75%) percentage of cesium on the cold anode surface. A relatively high cesium seed with a rate of about 20 mg/1 h/30 shots operation is necessary to support the increased H- production in the regular MS. Electrode processing by an additional discharge recovers the cesium from the aged coverage and enhances the H- production without an additional cesium seed. Recovery processing permits the use of deposited cesium more efficiently and to minimize cesium addition during the MS long-term operation. An essential decrease of cesium escape to accelerator and an improvement of injector high voltage operation is produced by introducing the shutter mask at plasma grid surface. The shutter mask experiment displayed, that >60% of H- beam current was born on the hot shutter mask surface. The source operation with a high negative shutter mask biasing and an increased hydrogen pressure resulted in a 35% higher H- yield, than of regular MS.

  20. Development of hollow anode penning ion source for laboratory application

    Science.gov (United States)

    Das, B. K.; Shyam, A.; Das, R.; Rao, A. D. P.

    2012-03-01

    The research work presented here focuses for the development of miniature penning type ion source. One hollow anode penning type ion source was developed in our laboratory. The size of the ion source is 38 mm diameter and 55 mm length. The ion source consists of two cathodes, a hollow anode and one piece of rare earth permanent magnet. The plasma was created in the plasma region between cathodes and the hollow anode. The J × B force in the region helps for efficient ionization of the gas even in the high vacuum region˜1×10 -5 Torr. The ions were extracted in the axial direction with help of the potential difference between the electrodes and the geometry of the extraction angle. The effect of the extraction electrode geometry for efficient extraction of the ions from the plasma region was examined. This ion source is a self extracted ion source. The self extracted phenomena reduce the cost and the size of the ion source. The extracted ion current was measured by a graphite probe. An ion current of more than 200 μA was observed at the probe placed 70 mm apart from the extraction electrode. In this paper, the structure of the ion source, effect of operating pressure, potential difference and the magnetic field on the extracted ion current is reported.

  1. The first experimental results on laser ion loading into superconducting ECR ion source at RIKEN

    CERN Document Server

    Arzumanyan, G M; Shirkov, G D; Yano, Y

    2002-01-01

    The first experimental results on ions and neutrals injection by means of laser ablation from metal targets into the RIKEN 18 GHz superconducting electron cyclotron resonance ion source (SC ECRIS) are presented. Pulsed aluminium ion currents up to Al sup 8 sup + were generated in the source. The difference in pulse shapes of various charge states of the extracted ion currents is registered

  2. Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator.

    Science.gov (United States)

    Kalvas, T; Welton, R F; Tarvainen, O; Han, B X; Stockli, M P

    2012-02-01

    A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H(-) ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H(-) currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  3. Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulatora)

    Science.gov (United States)

    Kalvas, T.; Welton, R. F.; Tarvainen, O.; Han, B. X.; Stockli, M. P.

    2012-02-01

    A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H- ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H- currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  4. Ion Source Development for Ultratrace Detection of Uranium and Thorium

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yuan [ORNL; Batchelder, Jon Charles [ORNL; Galindo-Uribarri, Alfredo {nmn} [ORNL; Stracener, Daniel W [ORNL

    2015-01-01

    A hot-cavity surface ionization source and a hot-cavity laser ion source are evaluated in terms of ionization efficiencies for generating ion beams of U and Th. The work is motivated by the need for more efficient ion sources for detecting ultratrace U and Th impurities in a copper matrix by mass spectrometry techniques such as accelerator mass spectrometry (AMS). The performances of the ion sources are characterized using uranyl nitrate and thorium nitrate sample materials and sample sizes of 20 - 40 g of U or Th. For the surface source, the dominant ion beams observed are UO+ or ThO+ and ionization efficiencies of 2-4% have been obtained with W and Re cavities. Three-step resonant photoionization of U atoms is studied and an ionization efficiency of 8.7% has been obtained with the laser ion source. The positive ion sources promise more than an order of magnitude more efficient than conventional Cs-sputter negative ion sources used for AMS. In addition, the laser ion source is highly selective and effective in suppressing interfering and ions. Work is in progress to improve the efficiencies of both positive ion sources.

  5. A singly charged ion source for radioactive {sup 11}C ion acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Katagiri, K.; Noda, A.; Nagatsu, K.; Nakao, M.; Hojo, S.; Muramatsu, M.; Suzuki, K.; Wakui, T.; Noda, K. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan)

    2016-02-15

    A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

  6. A singly charged ion source for radioactive 11C ion acceleration

    Science.gov (United States)

    Katagiri, K.; Noda, A.; Nagatsu, K.; Nakao, M.; Hojo, S.; Muramatsu, M.; Suzuki, K.; Wakui, T.; Noda, K.

    2016-02-01

    A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive 11C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

  7. Ions beams and ferroelectric plasma sources

    Science.gov (United States)

    Stepanov, Anton

    Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40 keV, perveance-dominated Ar+ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50 keV Ar + beam with pulse duration angle divergence of 0.87°. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5 mus after the fast-rising high voltage pulse is applied and lasts for tens

  8. Relative bioavailability of phosphorus in inorganic phosphorus sources fed to growing pigs.

    Science.gov (United States)

    Petersen, G I; Pedersen, C; Lindemann, M D; Stein, H H

    2011-02-01

    The relative bioavailability of P in 5 sources of inorganic P was determined using growing pigs. The 5 sources of inorganic P were dicalcium phosphate (DCP), monocalcium phosphate (MCP) containing 50% MCP (MCP50), MCP containing 70% MCP (MCP70), MCP containing 100% MCP (MCP100), and monosodium phosphate (MSP). A total of 11 diets were formulated. The basal diet was formulated to contain 0.10% P, and 10 additional diets were formulated by adding 0.07 or 0.14% P from each of the 5 P sources to the basal diet. Growing pigs (n = 44; initial BW: 16.8 ± 4.3 kg) were individually housed and randomly allotted to the 11 experimental diets. Feed was provided on an ad libitum basis throughout the 28-d experimental period. At the conclusion of the experiment, all pigs were killed, and 4 bones (i.e., the third and fourth metacarpals on both front feet) were harvested. Bone-breaking strength, bone ash, and Ca and P concentrations were determined. The concentration of bone ash increased (P DCP, but not different (P > 0.05) from that of pigs fed diets supplemented with MCP50 or MCP70. In conclusion, P in MSP and MCP100 is more bioavailable than P in DCP, but there were no differences within MCP sources.

  9. Experimental Verification of Surface Ionization in Ion Source

    Institute of Scientific and Technical Information of China (English)

    CAO; Jin-wen; REN; Xiu-yan; ZENG; Zi-qiang; DU; Xue-yuan

    2015-01-01

    The ion source is playing an important role in EMIS(Electro-Magnetic Isotope Separator),and its characteristics decide the capability of the EMIS and the isotope quality.The ion source has arc discharge chamber and extracting electrodes.The focusing electrode of the extracting electrodes extracts and focuses the ion beam,and

  10. Measurement of negative ion density in a pulsed multicusp negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Coonan, B.; Mellon, K.N.; Hopkins, M.B. (Dublin City University, Dublin (Ireland))

    1992-10-05

    The production of negative ion beams for use in neutral beam injection heating has become an important area of research in recent years. This paper discusses the negative ion densities measured in a pulsed multicusp volume ion source using photodetachment diagnostic technique. A pulse modulated negative ion source is being used as an alternative to the tandem source and an increase in negative ion extracted current has previously been observed by Hopkins and Mellon. Work with photodetachment quoted in this paper shows an increase in negative ion density during the post discharge similar to previous results obtained using an accelerator to extract the negative ions.

  11. Influence of different fibre sources on digestibility and nitrogen and energy balances in growing pigs

    DEFF Research Database (Denmark)

    Hansen, Michael Jørgen; Chwalibog, André; Tauson, Anne-Helene

    2006-01-01

    The present study was undertaken to investigate how three different fibre sources, sugar beet pulp, soya bean hulls and pectin residue, constituting 15% of diets for growing pigs, influenced daily body gain, feed conversion, apparent faecal digestibility and nitrogen and energy balances. Eight......, soya bean hulls and pectin residue in diets for growing pigs decreased the apparent faecal digestibility and in the diets with sugar beet pulp and pectin residue higher utilization of digested nitrogen for retention compensated for the lower amount of digested nitrogen....

  12. Influence of different fibre sources on digestibility and nitrogen and energy balances in growing pigs

    DEFF Research Database (Denmark)

    Hansen, Michael Jørgen; Chwalibog, André; Tauson, Anne-Helene

    2006-01-01

    The present study was undertaken to investigate how three different fibre sources, sugar beet pulp, soya bean hulls and pectin residue, constituting 15% of diets for growing pigs, influenced daily body gain, feed conversion, apparent faecal digestibility and nitrogen and energy balances. Eight......, soya bean hulls and pectin residue in diets for growing pigs decreased the apparent faecal digestibility and in the diets with sugar beet pulp and pectin residue higher utilization of digested nitrogen for retention compensated for the lower amount of digested nitrogen....

  13. Cooperation of divalent ions and thiamin diphosphate in regulation of the function of pig heart pyruvate dehydrogenase complex.

    Science.gov (United States)

    Czerniecki, J; Czygier, M

    2001-12-01

    The role of Mg2+, Ca2+, and Mn2+ in regulation of purified pig heart pyruvate dehydrogenase complex (PDC) containing endogenous thiamin diphosphate (TDP) was studied. It was found that the effects of the cations depended on the presence of exogenous TDP. In the absence of added TDP, the divalent cations led to a shortening of a lag phase of the PDC reaction and a strong reduction of the Km value for pyruvate. The relative efficiency of the three types of ions are presented as follows: Mn2+>Ca2+>Mg2+. The other sources claim that in the presence of exogenous TDP, which alone strongly increased the affinity of PDC for pyruvate, any significant additional effects of the cations were not observed. However, Mg2+, Ca2+, and Mn2+ decreased the Km value for CoA in both cases, the absence and presence of exogenous TDP, in approximately a similar extent (about twofold). The affinity of PDC for NAD+ seems to be not sensitive to the presence of the divalent cations. The data obtained suggest that Mg2+, Ca2+, and Mn2+ can cooperate with TDP as positive regulatory effectors of pig heart PDC on the level of pyruvate dehydrogenase and lipoamide acetyltransferase components of the complex.

  14. Magnetic plasma confinement for laser ion source.

    Science.gov (United States)

    Okamura, M; Adeyemi, A; Kanesue, T; Tamura, J; Kondo, K; Dabrowski, R

    2010-02-01

    A laser ion source (LIS) can easily provide a high current beam. However, it has been difficult to obtain a longer beam pulse while keeping a high current. On occasion, longer beam pulses are required by certain applications. For example, more than 10 micros of beam pulse is required for injecting highly charged beams to a large sized synchrotron. To extend beam pulse width, a solenoid field was applied at the drift space of the LIS at Brookhaven National Laboratory. The solenoid field suppressed the diverging angle of the expanding plasma and the beam pulse was widened. Also, it was observed that the plasma state was conserved after passing through a few hundred gauss of the 480 mm length solenoid field.

  15. Profile of new green fluorescent protein transgenic Jinhua pigs as an imaging source

    Science.gov (United States)

    Kawarasaki, Tatsuo; Uchiyama, Kazuhiko; Hirao, Atsushi; Azuma, Sadahiro; Otake, Masayoshi; Shibata, Masatoshi; Tsuchiya, Seiko; Enosawa, Shin; Takeuchi, Koichi; Konno, Kenjiro; Hakamata, Yoji; Yoshino, Hiroyuki; Wakai, Takuya; Ookawara, Shigeo; Tanaka, Hozumi; Kobayashi, Eiji; Murakami, Takashi

    2009-09-01

    Animal imaging sources have become an indispensable material for biological sciences. Specifically, gene-encoded biological probes serve as stable and high-performance tools to visualize cellular fate in living animals. We use a somatic cell cloning technique to create new green fluorescent protein (GFP)-expressing Jinhua pigs with a miniature body size, and characterized the expression profile in various tissues/organs and ex vivo culture conditions. The born GFP-transgenic pig demonstrate an organ/tissue-dependent expression pattern. Strong GFP expression is observed in the skeletal muscle, pancreas, heart, and kidney. Regarding cellular levels, bone-marrow-derived mesenchymal stromal cells, hepatocytes, and islet cells of the pancreas also show sufficient expression with the unique pattern. Moreover, the cloned pigs demonstrate normal growth and fertility, and the introduced GFP gene is stably transmitted to pigs in subsequent generations. The new GFP-expressing Jinhua pigs may be used as new cellular/tissue light resources for biological imaging in preclinical research fields such as tissue engineering, experimental regenerative medicine, and transplantation.

  16. Performance of positive ion based high power ion source of EAST neutral beam injector

    Science.gov (United States)

    Hu, Chundong; Xie, Yahong; Xie, Yuanlai; Liu, Sheng; Xu, Yongjian; Liang, Lizhen; Jiang, Caichao; Li, Jun; Liu, Zhimin

    2016-02-01

    The positive ion based source with a hot cathode based arc chamber and a tetrode accelerator was employed for a neutral beam injector on the experimental advanced superconducting tokamak (EAST). Four ion sources were developed and each ion source has produced 4 MW @ 80 keV hydrogen beam on the test bed. 100 s long pulse operation with modulated beam has also been tested on the test bed. The accelerator was upgraded from circular shaped to diamond shaped in the latest two ion sources. In the latest campaign of EAST experiment, four ion sources injected more than 4 MW deuterium beam with beam energy of 60 keV into EAST.

  17. Design and Construction of a Microwave Plasma Ion Source

    CERN Document Server

    Çınar, Kamil

    2011-01-01

    This thesis is about the designing and constructing a microwave ion source. The ions are generated in a thermal and dense hydrogen plasma by microwave induction. The plasma is generated by using a microwave source with a frequency of 2.45 GHz and a power of 700 W. The generated microwave is pulsing with a frequency of 50 Hz. The designed and constructed microwave system generates hydrogen plasma in a pyrex plasma chamber. Moreover, an ion extraction unit is designed and constructed in order to extract the ions from the generated hydrogen plasma. The ion beam extraction is achieved and ion currents are measured. The plasma parameters are determined by a double Langmuir probe and the ion current is measured by a Faraday cup. The designed ion extraction unit is simulated by using the dimensions of the designed and constructed ion extraction unit in order to trace out the trajectories of the extracted ions.

  18. Vacuum ARC ion sources - activities & developments at LBL

    Energy Technology Data Exchange (ETDEWEB)

    Brown, I. [Lawrence Berkeley Laboratory, CA (United States)

    1996-08-01

    The author describes work at LBL on the development and application of vacuum arc ion sources. Work has been done on vacuum spark sources - to produce very high charge states, studies of high charge states in magnetic field, hybrid ion source operation on metal/gas plasma, multipole operation, work on MEVVA V for implantation applications, development of broad beam sources, and removal of particles from the output of the source.

  19. Ion source development for ultratrace detection of uranium and thorium

    Science.gov (United States)

    Liu, Y.; Batchelder, J. C.; Galindo-Uribarri, A.; Chu, R.; Fan, S.; Romero-Romero, E.; Stracener, D. W.

    2015-10-01

    Efficient ion sources are needed for detecting ultratrace U and Th impurities in a copper matrix by mass spectrometry techniques such as accelerator mass spectrometry (AMS). Two positive ion sources, a hot-cavity surface ionization source and a resonant ionization laser ion source, are evaluated in terms of ionization efficiencies for generating ion beams of U and Th. The performances of the ion sources are characterized using uranyl nitrate and thorium nitrate sample materials with sample sizes between 20 and 40 μg of U or Th. For the surface ion source, the dominant ion beams observed are UO+ or ThO+ and ionization efficiencies of 2-4% have been obtained with W and Re cavities. With the laser ion source, three-step resonant photoionization of U atoms has been studied and only atomic U ions are observed. An ionization efficiency of about 9% has been demonstrated. The performances of both ion sources are expected to be further improved.

  20. MEMS ion source for mass spectrometer integrated on a chip

    Science.gov (United States)

    Szyszka, P.; Grzebyk, T.; Górecka-Drzazga, A.; Dziuban, J. A.

    2016-11-01

    The paper describes silicon-glass MEMS electron impact ion source developed for miniature mass spectrometer (MS) integrated on a chip. The device consists of the field emission electron source with an electrophoretically deposited carbon nanotube cathode and ion beam formation electrodes. Ion source structure has been fabricated using MEMS technology. A complete manufacturing process of the test structures has been successfully elaborated and implemented.

  1. Brewers dried yeast as a source of mannan oligosaccharides for weanling pigs.

    Science.gov (United States)

    White, L A; Newman, M C; Cromwell, G L; Lindemann, M D

    2002-10-01

    Brewers dried yeast, a source of mannan oligosaccharides (MOS), was assessed as an alternative to an antimicrobial agent (carbadox) for young pigs in two experiments. The yeast contained 5.2% MOS. Agglutination tests confirmed adsorption of several serovars of E. coli and Salmonella spp. onto the yeast product. In Exp. 1, seven replicates (five pigs per pen) of 22-d-old pigs were fed a nonmedicated basal diet or the basal diet with carbadox (55 mg/kg), yeast (3%), or a combination of 3% yeast and 2% citric acid for 28 d. Carbadox did not improve growth performance. Growth rate and feed intake were depressed (P yeast alone or in combination with acid. Log counts of total coliforms, Escherichia coli, and Clostridium perfringens in feces were not affected by diet, but Bifidobacteria spp. counts were lower (P yeast + acid diet and lactobacilli counts were higher (P yeast. Fecal pH and VFA concentrations and intestinal morphological traits were not consistently affected by diet. Serum IgG levels were elevated in the yeast + acid (P yeast and carbadox additions to the diet on enteric microbial populations in young pigs housed in isolation units were evaluated. Pigs (n = 24) were weaned at 11 d of age (4.1 kg BW) and placed in isolation chambers (two pigs per chamber) equipped with individual air filtering systems and excrement containers. Treatments were a nonmedicated basal diet and the basal diet with 55 mg/kg of carbadox or with 3% yeast. Diets were fed for 29 d, then each pig was orally dosed with approximately 9.5 x 10(8) CFU of E. coli K88. Daily fecal E. coli K88 counts were not different (P > 0.05) among treatments, but fecal shedding of carbadox-resistant coliforms was higher (P yeast (P Yeast reduced colonization oftotal coliforms in the duodenum,jejunum, cecum, and colon, but it did not have a consistent effect on colonization of E. coli K88. Pigs fed yeast tended (P yeast and carbadox had minimal effects on growth, microbial populations, and intestinal health

  2. High-Intensity, High Charge-State Heavy Ion Sources

    CERN Document Server

    Alessi, J

    2004-01-01

    There are many accelerator applications for high intensity heavy ion sources, with recent needs including dc beams for RIA, and pulsed beams for injection into synchrotrons such as RHIC and LHC. The present status of sources producing high currents of high charge state heavy ions will be reviewed. These sources include ECR, EBIS, and Laser ion sources. The benefits and limitations for these type sources will be described, for both dc and pulsed applications. Possible future improvements in these type sources will also be discussed.

  3. Hydrogen Plasma Generation with 200 MHz RF Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeongtae; Park, Kwangmook; Seo, Dong Hyuk; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The ion source for the system is required to be rugged with 2000 hours maintenance free operation time because it is installed in the vessel filled with SF6 gas at the pressure of 10 bar. A 200 MHz RF ion source is considered as an ion source. It is a simple construction and provides long life operation. The specifications of the ion source are 5 kV extraction voltage and 1 mA beam current referenced to the proton. RF ion source has been developed and undergone a performance test. Results of the test are presented. 200 MHz RF ion source is designated and manufactured. First of all test stand test of ion source are set up for a performance test of ion source. It includes a RF ion source, a 200-MHz RF system, beam extraction system, vacuum system, beam extraction system, and beam diagnostic system. At pressure of 1.2E-5 torr, hydrogen plasma is generated with net RF power 70 W. Pyrex tube surrounded by an inductive coil takes the role of vessel and discharge is enhanced with field of permanent magnets.

  4. The potential of genetically-engineered pigs in providing an alternative source of organs and cells for transplantation.

    Science.gov (United States)

    Cooper, David K C; Hara, Hidetaka; Ezzelarab, Mohamed; Bottino, Rita; Trucco, Massimo; Phelps, Carol; Ayares, David; Dai, Yifan

    2013-07-01

    There is a critical shortage of organs, cells, and corneas from deceased human donors worldwide. There are also shortages of human blood for transfusion. A potential solution to all of these problems is the transplantation of organs, cells, and corneas from a readily available animal species, such as the pig, and the transfusion of red blood cells from pigs into humans. However, to achieve these ends, major immunologic and other barriers have to be overcome. Considerable progress has been made in this respect by the genetic modification of pigs to protect their tissues from the primate immune response and to correct several molecular incompatibilities that exist between pig and primate. These have included knockout of genes responsible for the expression of major antigenic targets for primate natural anti-pig antibodies, insertion of human complement- and coagulation-regulatory transgenes, and knockdown of swine leukocyte antigens that stimulate the primate's adaptive immune response. As a result of these manipulations, the administration of novel immunosuppressive agents, and other innovations, pig hearts have now functioned in baboons for 6-8 months, pig islets have maintained normoglycemia in diabetic monkeys for > 1 year, and pig corneas have maintained transparency for several months. Clinical trials of pig islet transplantation are already in progress. Future developments will involve further genetic manipulations of the organ-source pig, with most of the genes that are likely to be beneficial already identified.

  5. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  6. Enhanced secondary ion emission with a bismuth cluster ion source

    Science.gov (United States)

    Nagy, G.; Walker, A. V.

    2007-04-01

    We have investigated the mechanism of secondary ion yield enhancement using Bin+ (n = 1-6) primary ions and three different samples - dl-phenylalanine, Irganox 1010 and polystyrene - adsorbed on Al, Si and Ag substrates. The largest changes in secondary ion yields are observed for Bi2+ and Bi3+ primary ions. Smaller increases in secondary ion yield are found using Bi4+, Bi5+ and Bi6+ projectiles. The secondary ion yield enhancements are generally larger on Si than on Al. Using Bin+ structures obtained from density functional theory (DFT) calculations we demonstrate that the yield enhancements cannot be explained by an increase in the deposited energy density (energy per area) into the substrate. These data show that the mechanism of Bin+ sputtering is very similar to that for Aun+ primary ion beams. When a polyatomic primary ion strikes the substrate, its constituent atoms are likely to remain near to each other, and so a substrate atom can be struck simultaneously by multiple atoms. The action of these multiple concerted impacts leads to efficient energy transfer in the near surface region and an increase in the number of secondary ions ejected from the surface. Such concerted impacts involve one, two or three projectile atoms, which explains well the nonlinear yield enhancements observed going from Bi+ to Bi2+ to Bi3+.

  7. ECR Ion Source Developments at the Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Alton, G.D.; Liu, Y.; Meyer, F.W.

    1998-10-05

    New techniques for enhancing the performances of electron cyclotron resonance (ECR) ion sources are being investigated at the Oak Ridge National Laboratory. We have utilized the multiple discrete frequency technique to improve the charge state distributions extracted from conventional magnetic field geometry ECR source by injecting three frequencies into the source. A new flat central magnetic field concept, has been incorporated in the designs of a compact all-permanent-magnet source for high charge-state ion beam generation and a compact electromagnetic source for singly ionized radioactive ion beam generation for use in the Holifield Radioactive Ion Beam Facility (HRIBF) research program. A review of the three frequency injection experiments and descriptions of the design aspects of the "volume-type" ECR ion sources will be given in this report.

  8. Development and testing of a lithium ion source and injector

    Science.gov (United States)

    Seidl, P. A.; Greenway, W. W.; Grote, D. P.; Jung, J.-Y.; Kwan, J. W.; Lidia, S. M.; Roy, P. K.; Takakuwa, J.; Vay, J.-L.; Waldron, W. L.

    2012-04-01

    We report on the development and testing of an intense lithium ion source and injector for an ion induction accelerator designed for warm, dense matter target heating experiments. The source is a 10.9-cm diameter aluminosilicate emitter on a porous tungsten substrate. For an injector voltage pulse of 120 kV, pulse duration of 1.0-μs FWHM, and an operating temperature of 1250°C, the source emits 35 mA of Li+ ions. The results follow experimental studies with much smaller sources. The key challenges included beam quality, source lifetime, and heat management.

  9. Ion Source Physics and Technology (1/2)

    CERN Document Server

    CERN. Geneva

    2016-01-01

    This series of lectures starts with an introduction in some aspects of atomic and plasma physics as base for the ion source physics. The main part covers aspects of ion source physics, technology and operation. Several source types are presented. Some information on infrastructure and supporting services (as high voltage, cooling, microwaves etc) are given to better understand the source environment. The last part on engineering aims to show that, in the field of ion sources, many different technologies are combined in a quite small environment, which is challenging and interesting at the same time.

  10. Ion Source Physics and Technology (2/2)

    CERN Document Server

    CERN. Geneva

    2016-01-01

    This series of lectures starts with an introduction in some aspects of atomic and plasma physics as base for the ion source physics. The main part covers aspects of ion source physics, technology and operation. Several source types are presented. Some information on infrastructure and supporting services (as high voltage, cooling, microwaves etc) are given to better understand the source environment. The last part on engineering aims to show that, in the field of ion sources, many different technologies are combined in a quite small environment, which is challenging and interesting at the same time.

  11. Development of a laser ion source at IGISOL

    Energy Technology Data Exchange (ETDEWEB)

    Moore, I D [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland); Nieminen, A [Schuster Laboratory, University of Manchester, Manchester M13 9PL (United Kingdom); Billowes, J [Schuster Laboratory, University of Manchester, Manchester M13 9PL (United Kingdom); Campbell, P [Schuster Laboratory, University of Manchester, Manchester M13 9PL (United Kingdom); Geppert, Ch [Institut fuer Physik, Johannes Gutenberg-Universitaet, 55099 Mainz (Germany); Jokinen, A [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland); Kessler, T [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland); Marsh, B [Schuster Laboratory, University of Manchester, Manchester M13 9PL (United Kingdom); Penttilae, H [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland); Rinta-Antila, S [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland); Tordoff, B [Schuster Laboratory, University of Manchester, Manchester M13 9PL (United Kingdom); Wendt, K D A [Institut fuer Physik, Johannes Gutenberg-Universitaet, 55099 Mainz (Germany); Aystoe, J [Accelerator Laboratory, University of Jyvaeskylae, FIN-40014 (Finland)

    2005-10-01

    FURIOS, the Fast Universal laser IOn Source, is under development at the IGISOL (Ion Guide Isotope Separator On-Line) mass separator facility in Jyvaeskylae, Finland. This new laser ion source will combine a state-of-the-art solid state laser system together with a dye laser system, for the selective and efficient production of exotic radioactive species without compromising the universality and fast release inherent in the IGISOL system. The motivation for, and development of, this ion source is discussed in relation to the programme of research ongoing at this mass separator facility.

  12. Verification of high efficient broad beam cold cathode ion source

    Science.gov (United States)

    Abdel Reheem, A. M.; Ahmed, M. M.; Abdelhamid, M. M.; Ashour, A. H.

    2016-08-01

    An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.

  13. Programming Pig

    CERN Document Server

    Gates, Alan

    2011-01-01

    This guide is an ideal learning tool and reference for Apache Pig, the open source engine for executing parallel data flows on Hadoop. With Pig, you can batch-process data without having to create a full-fledged application-making it easy for you to experiment with new datasets. Programming Pig introduces new users to Pig, and provides experienced users with comprehensive coverage on key features such as the Pig Latin scripting language, the Grunt shell, and User Defined Functions (UDFs) for extending Pig. If you need to analyze terabytes of data, this book shows you how to do it efficiently

  14. Status report of the ECR ion sources at the KVI

    NARCIS (Netherlands)

    Drentje, A. G.; Barzangy, F.; Kremers, H. R.; Meyer, D.; Mulder, J.; Sijbring, J.

    1999-01-01

    Abstract: At the moment three ECR ion sources are in operation at the KVI. One of these is being used as the ionizer section of the polarized ion (protons and deuterons) source POLIS; it runs at 2.5 GHz. In this paper the emphasis will be on the other two ECRISs, both being used for the production o

  15. Compact ECR ion source with permanent magnets for Carbon therapy

    NARCIS (Netherlands)

    Muramatsu, M; Kitagawa, A; Sakamoto, Y; Sato, Y; Yamada, S; Ogawa, H; Drentje, AG; Biri, S; Yoshida, Y

    Ion sources for the medical facilities should have the following characteristics of easy maintenance, low electric power, good stability, and long operation time without trouble (1 year or longer). For this, a 10 GHz compact electron cyclotron resonance ion source (ECRIS) with all permanent magnets

  16. Volume and Surface-Enhanced Volume Negative Ion Sources

    CERN Document Server

    Stockli, M P

    2013-01-01

    H- volume sources and, especially, caesiated H- volume sources are important ion sources for generating high-intensity proton beams, which then in turn generate large quantities of other particles. This chapter discusses the physics and technology of the volume production and the caesium-enhanced (surface) production of H- ions. Starting with Bacal's discovery of the H- volume production, the chapter briefly recounts the development of some H- sources, which capitalized on this process to significantly increase the production of H- beams. Another significant increase was achieved in the 1990s by adding caesiated surfaces to supplement the volume-produced ions with surface-produced ions, as illustrated with other H- sources. Finally, the focus turns to some of the experience gained when such a source was successfully ramped up in H- output and in duty factor to support the generation of 1 MW proton beams for the Spallation Neutron Source.

  17. Negative ions as a source of low energy neutral beams

    Energy Technology Data Exchange (ETDEWEB)

    Fink, J.H.

    1980-01-01

    Little consideration has been given to the impact of recent developments in negative ion source technology on the design of low energy neutral beam injectors. However, negative ion sources of improved operating efficiency, higher gas efficiency, and smaller beam divergence will lead to neutral deuterium injectors, operating at less than 100 keV, with better operating efficiencies and more compact layouts than can be obtained from positive ion systems.

  18. Sources and detectors of fast ions for basic devices

    OpenAIRE

    Furno, Ivo; Fasoli, Ambrogio; Plyushchev, Gennady

    2009-01-01

    The physics of supra thermal test ions in turbulent plasmas can be conveniently studied in basic plasma physics devices, which allow high-resolution measurements of plasma and fast ion parameters and wave fields throughout the whole plasma cross-section. We describe recent advances in the development of an experimental setup consisting of a non-perturbative Li 6+ miniaturized ion source and a detector for the investigation of the interaction between supra thermal ions and drift/interchange–dr...

  19. GISELE: A resonant ionization laser ion source for the production of radioactive ions at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Lecesne, N.; Alves-Conde, R.; De Oliveira, F.; Dubois, M.; Flambard, J. L.; Franberg, H.; Jardin, P.; Leroy, R.; Pacquet, J. Y.; Pichard, A.; Saint-Laurent, M. G. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Coterreau, E.; Le Blanc, F.; Olivier, A. [IPN Orsay, BP 1-91406 Orsay (France); Gottwald, T.; Mattolat, C.; Wendt, K. [Johannes Gutenberg-Universitaet Mainz, Staudinger Weg 7, 55099 Mainz (Germany); Lassen, J. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Rothe, S. [Department of Engineering, CERN, CH-1211 Geneva 23 (Switzerland)

    2010-02-15

    SPIRAL2 is the new project under construction at GANIL to produce radioactive ion beams and in particular neutron rich ion beams. For the past 10 yr SPIRAL1 at GANIL has been delivering accelerated radioactive ion beams of gases. Both facilities now need to extend the range of radioactive ion beams produced to condensable elements. For that purpose, a resonant ionization laser ion source, funded by the French Research National Agency, is under development at GANIL, in collaboration with IPN Orsay, University of Mainz (Germany) and TRIUMF, Vancouver (Canada). A description of this project called GISELE (GANIL Ion Source using Electron Laser Excitation) is presented.

  20. GISELE: A resonant ionization laser ion source for the production of radioactive ions at GANIL

    CERN Document Server

    Lecesne, N; Wendt, K; Mattolat, C; Rothe, S; Pichard, A; Pacquet, J Y; Dubois, M; Coterreau, E; Franberg, H; Leroy, R; Gottwald, T; Alves-Conde, R; Flambard, J L; De Oliveira, F; Le Blanc, F; Jardin, P; Olivier, A; Lassen, J

    2010-01-01

    SPIRAL2 is the new project under construction at GANIL to produce radioactive ion beams and in particular neutron rich ion beams. For the past 10 yr SPIRAL1 at GANIL has been delivering accelerated radioactive ion beams of gases. Both facilities now need to extend the range of radioactive ion beams produced to condensable elements. For that purpose, a resonant ionization laser ion source, funded by the French Research National Agency, is under development at GANIL, in collaboration with IPN Orsay, University of Mainz (Germany) and TRIUMF, Vancouver (Canada). A description of this project called GISELE (GANIL Ion Source using Electron Laser Excitation) is presented.

  1. Small radio frequency driven multicusp ion source for positive hydrogen ion beam production

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, L.T.; Herz, P.R.; Leung, K.N.; Pickard, D.S. (Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (United States))

    1994-04-01

    A compact, 2.5 cm diam rf-driven multicusp ion source has been developed and tested for H[sup +] ion production in pulse mode operation. The source is optimized for atomic hydrogen ion species and extractable current. It is found that hydrogen ion beam current densities in excess of 650 mA/cm[sup 2] can be achieved with H[sup +] species above 80%. The geometry and position of the porcelain-coated copper antenna were found to be of great significance in relation to the efficiency of the ion source.

  2. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)

    Science.gov (United States)

    Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  3. Molecular and negative ion production by a standard electron cyclotron resonance ion source.

    Science.gov (United States)

    Rácz, R; Biri, S; Juhász, Z; Sulik, B; Pálinkás, J

    2012-02-01

    Molecular and negative ion beams, usually produced in special ion sources, play an increasingly important role in fundamental and applied atomic physics. The ATOMKI-ECRIS is a standard ECR ion source, designed to provide highly charged ion (HCI) plasmas and beams. In the present work, H(-), O(-), OH(-), O(2)(-), C(-), C(60)(-) negative ions and H(2)(+), H(3)(+), OH(+), H(2)O(+), H(3)O(+), O(2)(+) positive molecular ions were generated in this HCI-ECRIS. Without any major modification in the source and without any commonly applied tricks (such as usage of cesium or magnetic filter), negative ion beams of several μA and positive molecular ion beams in the mA range were successfully obtained.

  4. Charge state distribution analysis of Al and Pb ions from the laser ion source at IMP

    CERN Document Server

    Shan, Sha; Zhang-Min, Li; Xiao-Hong, Guo; Lun-Cai, Zhou; Guo-Zhu, Cai; Liang-ting, Sun; Xue-Zhen, Zhang; Huan-Yu, Zhao; Xi-Meng, Chen; Hong-Wei, Zhao

    2013-01-01

    A prototype laser ion source that could demonstrate the possibility of producing intense pulsed high charge state ion beams has been established with a commercial Nd:YAG laser (E max = 3 J, 1064 nm, 8-10 ns) to produce laser plasma for the research of Laser Ion Source (LIS). At the laser ion source test bench, high purity (99.998 %) aluminum and lead targets have been tested for laser plasma experiment. An Electrostatic Ion Analyzer (EIA) and Electron Multiply Tube (EMT) detector were used to analyze the charge state and energy distribution of the ions produced by the laser ion source. The maximum charge states of Al12+ and Pb7+ were achieved. The results will be presented and discussed in this paper.

  5. Numerical model of electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2015-12-01

    Full Text Available Important features of the electron cyclotron resonance ion source (ECRIS operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model the dynamics of ions in ECRIS plasma. It is shown that a gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion currents are calculated and compared to the experiment for a few sources. Changes in the simulated extracted ion currents are obtained with varying the gas flow into the source chamber and the microwave power. Empirical scaling laws for ECRIS design are studied and the underlying physical effects are discussed.

  6. Some plasma aspects and plasma diagnostics of ion sources.

    Science.gov (United States)

    Wiesemann, Klaus

    2008-02-01

    We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma -- basic data for plasma modeling.

  7. Transverse emittance investigation of the ISOLDE target ion sources

    CERN Document Server

    Lettry, Jacques; Wenander, F

    2003-01-01

    In order to produce target-ion sources allowing for a high isotopic resolution in the separator, CERN/ISOLDE (Isotope Separator On Line) has purchased a commercial emittance metre, capable of measuring transverse phase-space emittances for ion-beam intensities down to approximately 1 nA. It was installed at the ISOLDE off-line separator where targets are tested with respect to material purity and the ion-source efficiencies are determined. Now, also the emittance and brightness are measured for different stable elements. An extensive programme has been launched aiming at a complete survey of the emittance dependence on the various ion-source parameters. Results from the measurements on the different ISOLDE ion-source types, with associated analysis, are presented.

  8. Oxygen ion source and RFQ for Linac 1

    CERN Multimedia

    Photographic Service

    1986-01-01

    As injector to the PS Booster, Linac 1 was replaced by Linac 2 in 1980. It continued to be used for the acceleration of oxygen and sulfur ions. In 1984, its Cockcroft-Walton preinjector was replaced by an RFQ. In the foreground at the right is the oxygen ion source. A 90 deg bending magnet selects O6+ ions which are preaccelerated in an RFQ and enter Linac 1, at the far left. In the background is the proton and negative hydrogen ion source, followed by the 520 keV RFQ-1 and a bending magnet towards the entrance of Linac 1.

  9. Ion source issues for the DAEδALUS neutrino experiment

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Jose R., E-mail: JRAlonso@LBL.gov; Barletta, William A.; Toups, Matthew H.; Conrad, Janet [Laboratory for Nuclear Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Liu, Y.; Bannister, Mark E.; Havener, C. C.; Vane, Randy [Physics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2014-02-15

    The DAEδALUS experiment calls for 10 mA of protons at 800 MeV on a neutrino-producing target. To achieve this record-setting current from a cyclotron system, H{sub 2}{sup +} ions will be accelerated. Loosely bound vibrationally excited H{sub 2}{sup +} ions inevitably produced in conventional ion sources will be Lorentz stripped at the highest energies. Presence of these states was confirmed at the Oak Ridge National Laboratory and strategies were investigated to quench them, leading to a proposed R and D effort towards a suitable ion source for these high-power cyclotrons.

  10. New ion source for KSTAR neutral beam injection system.

    Science.gov (United States)

    Kim, Tae-Seong; Jeong, Seung Ho; In, Sang-Ryul

    2012-02-01

    The neutral beam injection system (NBI-1) of the KSTAR tokamak can accommodate three ion sources; however, it is currently equipped with only one prototype ion source. In the 2010 and 2011 KSTAR campaigns, this ion source supplied deuterium neutral beam power of 0.7-1.6 MW to the KSTAR plasma with a beam energy of 70-100 keV. A new ion source will be prepared for the 2012 KSTAR campaign with a much advanced performance compared with the previous one. The newly designed ion source has a very large transparency (∼56%) without deteriorating the beam optics, which is designed to deliver a 2 MW injection power of deuterium beams at 100 keV. The plasma generator of the ion source is of a horizontally cusped bucket type, and the whole inner wall, except the cathode filaments and plasma grid side, functions as an anode. The accelerator assembly consists of four multi-circular aperture grids made of copper and four electrode flanges made of aluminum alloy. The electrodes are insulated using PEEK. The ion source will be completed and tested in 2011.

  11. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  12. Influence of ion species ratio on grid-enhanced plasma source ion implantation

    Institute of Scientific and Technical Information of China (English)

    Wang Jiu-Li; Zhang Gu-Ling; Liu Yuan-Fu; Wang You-Nian; Liu Chi-Zi; Yang Si-Ze

    2004-01-01

    @@ Grid-enhanced plasma source ion implantation (GEPSII) is a newly proposed technique to modify the inner-surface properties of a cylindrical bore. In this paper, a two-ion fluid model describing nitrogen molecular ions N2+ and atomic ions N+ is used to investigate the ion sheath dynamics between the grid electrode and the inner surface of a cylindrical bore during the GEPSII process, which is an extension of our previous calculations in which only N2+ was considered.Calculations are concentrated on the results of ion dose and impact energy on the target for different ion species ratios in the core plasma. The calculated results show that more atomic ions N+ in the core plasma can raise the ion impact energy and reduce the ion dose on the target.

  13. Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Drentje, A. G.; Kitagawa, A.; Muramatsu, M.

    2010-01-01

    In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms

  14. A vacuum spark ion source: High charge state metal ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Yushkov, G. Yu., E-mail: gyushkov@mail.ru; Nikolaev, A. G.; Frolova, V. P. [High Current Electronics Institute, Siberian Branch of the Russian Academy of Science, Tomsk 634055 (Russian Federation); Oks, E. M. [High Current Electronics Institute, Siberian Branch of the Russian Academy of Science, Tomsk 634055 (Russian Federation); Tomsk State University of Control System and Radioelectronics, Tomsk 634050 (Russian Federation)

    2016-02-15

    High ion charge state is often important in ion beam physics, among other reasons for the very practical purpose that it leads to proportionately higher ion beam energy for fixed accelerating voltage. The ion charge state of metal ion beams can be increased by replacing a vacuum arc ion source by a vacuum spark ion source. Since the voltage between anode and cathode remains high in a spark discharge compared to the vacuum arc, higher metal ion charge states are generated which can then be extracted as an ion beam. The use of a spark of pulse duration less than 10 μs and with current up to 10 kA allows the production of ion beams with current of several amperes at a pulse repetition rate of up to 5 pps. We have demonstrated the formation of high charge state heavy ions (bismuth) of up to 15 + and a mean ion charge state of more than 10 +. The physics and techniques of our vacuum spark ion source are described.

  15. A vacuum spark ion source: High charge state metal ion beams

    Science.gov (United States)

    Yushkov, G. Yu.; Nikolaev, A. G.; Oks, E. M.; Frolova, V. P.

    2016-02-01

    High ion charge state is often important in ion beam physics, among other reasons for the very practical purpose that it leads to proportionately higher ion beam energy for fixed accelerating voltage. The ion charge state of metal ion beams can be increased by replacing a vacuum arc ion source by a vacuum spark ion source. Since the voltage between anode and cathode remains high in a spark discharge compared to the vacuum arc, higher metal ion charge states are generated which can then be extracted as an ion beam. The use of a spark of pulse duration less than 10 μs and with current up to 10 kA allows the production of ion beams with current of several amperes at a pulse repetition rate of up to 5 pps. We have demonstrated the formation of high charge state heavy ions (bismuth) of up to 15 + and a mean ion charge state of more than 10 +. The physics and techniques of our vacuum spark ion source are described.

  16. Recent advances in high current vacuum arc ion sources for heavy ion fusion

    CERN Document Server

    Qi Nian Sheng; Prasad, R R; Krishnan, M S; Anders, A; Kwan, J; Brown, I

    2001-01-01

    For a heavy ion fusion induction linac driver, a source of heavy ions with charge states 1+-3+, approx 0.5 A current beams, approx 20 mu s pulse widths and approx 10 Hz repetition rates is required. Thermionic sources have been the workhorse for the Heavy Ion Fusion (HIF) program to date, but suffer from heating problems for large areas and contamination. They are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states in short and long pulse bursts and high beam current density. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications was investigated. We have modifie...

  17. ACCELERATORS Control system for the CSNS ion source test stand

    Science.gov (United States)

    Lu, Yan-Hua; Li, Gang; Ouyang, Hua-Fu

    2010-12-01

    A penning plasma surface H- ion source test stand for the CSNS has just been constructed at the IHEP. In order to achieve a safe and reliable system, nearly all devices of the ion source are designed to have the capability of both local and remote operation function. The control system consists of PLCs and EPICS real-time software tools separately serving device control and monitoring, PLC integration and OPI support. This paper summarizes the hardware and software implementation satisfying the requirements of the ion source control system.

  18. Electron beam ion source and electron beam ion trap (invited)a)

    Science.gov (United States)

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  19. Dietary conjugated linoleic acid changes belly and bacon quality from pigs fed varied lipid sources.

    Science.gov (United States)

    Larsen, S T; Wiegand, B R; Parrish, F C; Swan, J E; Sparks, J C

    2009-01-01

    The objective of this experiment was to determine the effects of dietary lipid source with or without the addition of CLA on bacon composition and quality. Forty-eight barrows at a beginning BW of 55 kg +/- 2.2 were fed 1 of 6 diets for 56 d. These diets consisted of: 1) normal corn (NC), 2) NC + 1.25% CLA-60 oil (NC + CLA), 3) high-oil corn (HOC), 4) HOC + 1.25% CLA-60 oil (HOC-CLA), 5) NC + choice white grease (CWG; NC + CWG), and 6) NC + CWG + 1.25% CLA-60 oil (NC + CWG + CLA). The CLA-60 contains 60% CLA isomers in the oil, and therefore, 1.25% oil was needed to achieve 0.75% CLA in the diet. Soy oil replaced CLA in control diets. Choice white grease and high-oil corn were selected as fat sources for this study because of their utility in energy density for growing-finishing pigs, especially in hot weather. Pigs were slaughtered at an average BW of 113 kg +/- 4.1, and carcasses were fabricated at 24 h postmortem. Statistical analysis was performed using the mixed model procedure of SAS, and the main effects tested were dietary lipid source, CLA, and 2-way interaction. The addition of CLA to each basal diet improved (P bacon slabs showed that bacon from CLA-supplemented pigs was approximately 20% firmer than that from controls. Pigs fed the HOC diets had softer bellies compared (P bacon sliceability. No differences were observed for moisture, protein, or lipid percentages between any treatments. Overall, there was a CLA effect (P bacon oxidation (0.1498 CLA vs. 0.1638 no CLA). Dietary CLA increased the percentage of SFA in tissues from pigs supplemented with CLA. Dietary inclusion of CLA increased the concentration of all measured isomers of CLA in bacon. Sensory scores of bacon showed no differences for any of the sensory attributes measured between any of the treatments. Our results indicate that inclusion of dietary CLA will improve belly firmness, extend the shelf life stability of bacon, and increase the degree of fat saturation.

  20. Simulation methods of ion sheath dynamics in plasma source ion implantation

    Institute of Scientific and Technical Information of China (English)

    WANG Jiuli; ZHANG Guling; WANG Younian; LIU Yuanfu; LIU Chizi; YANG Size

    2004-01-01

    Progress of the theoretical studies on the ion sheath dynamics in plasma source ion implantation (PSII) is reviewed in this paper. Several models for simulating the ion sheath dynamics in PSII are provided. The main problem of nonuniform ion implantation on the target in PSII is discussed by analyzing some calculated results. In addition, based on the relative researches in our laboratory, some calculated results of the ion sheath dynamics in PSII for inner surface modification of a cylindrical bore are presented. Finally, new ideas and tendency for future researches on ion sheath dynamics in PSII are proposed.

  1. A New Technique for Diagnosing Multi-charged Ion Beams Produced by ECR Ion Source

    Institute of Scientific and Technical Information of China (English)

    ZhangZimin; ZhaoHongwei; CaoYun; MaLei; MaBaohua; LiJinyu; WangHui; FengYucheng; DuJunfeng

    2003-01-01

    In order to study the transmission properties of multi-charged ion beams between the ECR ion source and the analyzing magnet, a new diagnostic system composed of three Wien-filters with three single-wires has been built and installed on the IMP ECR source test bcnch. The single-wire is used to measure the beam profile and the beam density distribution, and the Wien-filter is used to measure the charge state distribution of ion beam.

  2. Design Studies of a Multicusp Ion Source with FEMLAB Simulation

    Science.gov (United States)

    Azadboni, Fatemeh Khodadadi; Sedaghatizade, Mahmood; Sepanloo, Kamran

    2010-02-01

    Femlab simulations have been used to arrive at the first step in the design of an ion source. The goal is to optimize Magnetic multipole plasma confinement geometries, the increased area of constant magnetic field in the central region of the plasma volume and the increase in number of electrons which have stationary orbits within this region of the field. The confinement of electrons is essential for Multicusp ion source to produce intense beams of negative hydrogen ions (H-). A higher electron temperature and density given by a better plasma confinement leads to the higher efficiencies of the ionization and the production of highly charged ions. We have performed Femlab simulations of the magnetic flux density from permanent magnet used for a Multicusp ion source, plasma confinement and trapping of fast electrons by the magnetic field.

  3. Ionization efficiency estimations for the SPES surface ion source

    Science.gov (United States)

    Manzolaro, M.; Andrighetto, A.; Meneghetti, G.; Rossignoli, M.; Corradetti, S.; Biasetto, L.; Scarpa, D.; Monetti, A.; Carturan, S.; Maggioni, G.

    2013-12-01

    Ion sources play a crucial role in ISOL (Isotope Separation On Line) facilities determining, with the target production system, the ion beam types available for experiments. In the framework of the SPES (Selective Production of Exotic Species) INFN (Istituto Nazionale di Fisica Nucleare) project, a preliminary study of the alkali metal isotopes ionization process was performed, by means of a surface ion source prototype. In particular, taking into consideration the specific SPES in-target isotope production, Cs and Rb ion beams were produced, using a dedicated test bench at LNL (Laboratori Nazionali di Legnaro). In this work the ionization efficiency test results for the SPES Ta surface ion source prototype are presented and discussed.

  4. A review of ion sources for medical accelerators (invited).

    Science.gov (United States)

    Muramatsu, M; Kitagawa, A

    2012-02-01

    There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10(10) pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV∕u. Although the beam intensity depends on the irradiation method, it is typically several 10(8) or 10(9) pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are

  5. Isotope effects in a multicusp tandem ion source

    Energy Technology Data Exchange (ETDEWEB)

    Graham, W.G. (Department of Pure and Applied Physics, Queen' s University, Belfast BT7 1NN (Northern Ireland))

    1992-10-05

    Measurements of plasma parameters, including electron density, electron energy distribution function (eedf), and negative ion density, have been made in the driver and extractor regions of a multicusp tandem ion source. Here results which focus on comparing operation in hydrogen and deuterium are presented. Several isotope effects are evident. In particular, for the same operating conditions, the electron density is found to be higher in deuterium than in hydrogen while the negative ion density is consistently lower.

  6. Investigation of multi-charged heavy ion production in an electron beam ion source

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.

    1977-12-01

    Measurements of multi-charged heavy ions produced in an Electron Beam Ion Source (EBIS) were carried out with a test model ion source 20 cm in length. This test model utilized an electron gun placed external to the bore of the focusing solenoid in order to achieve electrostatically focussed electron beams and isolation of the vacuum surrounding the electron gun from the vacuum in the ionization region within the solenoid bore. An ultrahigh vacuum system utilizing liquid nitrogen (77/sup 0/K) cryopumping was used to achieve the low pressures needed in the ionization region for the operation of this ion source. Several technical problems limited the operation of this test model and prevented a thorough investigation of the ionization processes in the ion source, but the experimental results have shown qualitative agreement with the theoretical calculations for the operation of this type of ion source. Even with the problems of an insufficient vacuum and electron beam focussing field, measurable currents of C/sup +5/ and A/sup +8/ ions were produced. The present experimental results suggest that the approach taken in this work of using an external electron gun and cryopumping in the EBIS to achieve the large electron beam current density and low vacuum necessary for successful operation is a viable one. Such an ion source can be used to create highly-charged heavy ions for injection into a cyclotron or other type of particle accelerator.

  7. Ge and Ti post-ion acceleration from laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, L., E-mail: Lorenzo.Torrisi@unime.i [INFN-LNS di Catania, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica, Universita di Messina, Ctr. Papardo 31, 98166 S. Agata, Messina (Italy); Giuffrida, L. [INFN-LNS di Catania, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica, Universita di Messina, Ctr. Papardo 31, 98166 S. Agata, Messina (Italy); Rosinski, M. [Institute of Plasma Physics and Laser Microfusion, 23 Hery Str. 01-497 Warsaw (Poland); Schallhorn, C. [Department of Physics, University of California, Portola Plaza 430, 90095 Los Angeles, CA (United States)

    2010-09-15

    Laser ion sources (LIS) are employed with success to generate, in vacuum, Ge and Ti ion beams with high current, ion energy, charge states and directivity. Nanoseconds infrared laser pulses, with intensities of the order of 10{sup 10} W/cm{sup 2}, induce high ablation in Ge and Ti targets. Ions are produced in vacuum with energy distribution following the Coulomb-Boltzmann-shifted distribution and they are ejected mainly along the normal to the target surface. The free ion expansion process occurs in a constant-potential chamber placed at 30 kV positive voltage. An electric field of 5 kV/cm was used to accelerate the ions emitted from the plasma at INFN-LNS laser facility. Time-of-flight technique is employed to measure the mean ion energies of the post-accelerated particles. Ion charge states and energy distributions were measured through an ion energy spectrometer.

  8. Ge and Ti post-ion acceleration from laser ion source

    Science.gov (United States)

    Torrisi, L.; Giuffrida, L.; Rosinski, M.; Schallhorn, C.

    2010-09-01

    Laser ion sources (LIS) are employed with success to generate, in vacuum, Ge and Ti ion beams with high current, ion energy, charge states and directivity. Nanoseconds infrared laser pulses, with intensities of the order of 10 10 W/cm 2, induce high ablation in Ge and Ti targets. Ions are produced in vacuum with energy distribution following the Coulomb-Boltzmann-shifted distribution and they are ejected mainly along the normal to the target surface. The free ion expansion process occurs in a constant-potential chamber placed at 30 kV positive voltage. An electric field of 5 kV/cm was used to accelerate the ions emitted from the plasma at INFN-LNS laser facility. Time-of-flight technique is employed to measure the mean ion energies of the post-accelerated particles. Ion charge states and energy distributions were measured through an ion energy spectrometer.

  9. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    Energy Technology Data Exchange (ETDEWEB)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-04-28

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 μs pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV.

  10. A compact filament-driven multicusp ion source

    Science.gov (United States)

    Lee, Y.; Gough, R. A.; Kunkel, W. B.; Leung, K. N.; Perkins, L. T.; Pickard, D. S.; Sun, L.; Vujic, J.; Williams, M. D.; Wutte, D.

    1996-12-01

    A compact filament-driven multicusp ion source has been studied using both hydrogen and helium. Three aspects of the source have been investigated: hydrogen ion species, axial energy spread and extractable current. An atomic ion fraction (H +) of approximately 30% could be obtained with a discharge power of 80 V and 3 A. A magnetic analyzer was used to determine the axial energy spread of the extracted (i.e. accelerated) ion beam species, and an electrostatic energy analyzer was used to determine the energy spread of the ions at the source exit. The energy spread of the extracted beam for the individual species of positive hydrogen ions (H +, H 2+, H 3+) and that for the negative hydrogen ions (H -) was measured as well. Energy spreads as low as 2.3 eV were obtained for H +, 2 eV for H 2+, 1.7 eV for H 3+, and 1 eV for H -. The axial energy spread in the source exit without extraction for hydrogen and helium was measured to be approximately 1 eV for both cases. The source can generate a hydrogen beam current density of approximately 12 mA/cm 2.

  11. Focused ion beams using a high-brightness plasma source

    Science.gov (United States)

    Guharay, Samar

    2002-10-01

    High-brightness ion beams, with low energy spread, have merits for many new applications in microelectronics, materials science, and biology. Negative ions are especially attractive for the applications that involve beam-solid interactions. When negative ions strike a surface, especially an electrically isolated surface, the surface charging voltage is limited to few volts [1]. This property can be effectively utilized to circumvent problems due to surface charging, such as device damage and beam defocusing. A compact plasma source, with the capability to deliver either positive or negative ion beams, has been developed. H- beams from this pulsed source showed brightness within an order of magnitude of the value for beams from liquid-metal ion sources. The beam angular intensity is > 40 mAsr-1 and the corresponding energy spread is 1 Acm-2 and a spot size of 100 nm. Such characteristics of focused beam parameters, using a dc source, will immediately open up a large area of new applications. [1] P. N. Guzdar, A. S. Sharma, S. K. Guharay, "Charging of substrates irradiated by particle beams" Appl. Phys. Lett. 71, 3302 (1997). [2] S. K. Guharay, E. Sokolovsky, J. Orloff, "Characteristics of ion beams from a Penning source for focused ion beam applications" J. Vac. Sci Technol. B17, 2779 (1999).

  12. Recent Operation of the FNAL Magnetron H- Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Karns, Patrick R. [Fermilab; Bollinger, D. S. [Fermilab; Sosa, A. [Fermilab

    2016-09-06

    This paper will detail changes in the operational paradigm of the Fermi National Accelerator Laboratory (FNAL) magnetron H- ion source due to upgrades in the accelerator system. Prior to November of 2012 the H- ions for High Energy Physics (HEP) experiments were extracted at ~18 keV vertically downward into a 90 degree bending magnet and accelerated through a Cockcroft-Walton accelerating column to 750 keV. Following the upgrade in the fall of 2012 the H- ions are now directly extracted from a magnetron at 35 keV and accelerated to 750 keV by a Radio Frequency Quadrupole (RFQ). This change in extraction energy as well as the orientation of the ion source required not only a redesign of the ion source, but an updated understanding of its operation at these new values. Discussed in detail are the changes to the ion source timing, arc discharge current, hydrogen gas pressure, and cesium delivery system that were needed to maintain consistent operation at >99% uptime for HEP, with an increased ion source lifetime of over 9 months.

  13. Performance characterization of rf-driven multicusp ion sources

    Science.gov (United States)

    Perkins, L. T.; De Vries, G. J.; Herz, P. R.; Kunkel, W. B.; Leung, K. N.; Pickard, D. S.; Wengrow, A.; Williams, M. D.

    1996-03-01

    Radio-frequency (rf)-driven multicusp ion sources have been developed extensively at Lawrence Berkeley National Laboratory (LBNL) for many applications, each requiring specific source designs. These uses have ranged from large ion sources for neutral-beam injectors—several tens of centimeters in size—to small sources for oil-well logging neutron tubes—a few centimeters in diameter. The advantages associated with internal antenna, rf-driven ion sources include reliability, long component life, ease of operation, and the ability to generate plasmas free of the impurities commonly found in hot-filament discharge sources. We have investigated and characterized the performance of rf-driven sources with respect to the rf operating frequency and ion source size for hydrogen ion species and current density. Furthermore, we have included in this study the aspects of proper coupling of the rf generator to the antenna through an impedance matching network. Finally, critical issues pertaining to general rf operation including beam extraction, rf shielding, and cooling of transformer cores are discussed.

  14. Performance characterization of rf-driven multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, L.T.; De Vries, G.J.; Herz, P.R.; Kunkel, W.B.; Leung, K.N.; Pickard, D.S.; Wengrow, A.; Williams, M.D. [Lawrence Berkeley National Laboratory, University of California at Berkeley, Berkeley, California 94720 (United States)

    1996-03-01

    Radio-frequency (rf)-driven multicusp ion sources have been developed extensively at Lawrence Berkeley National Laboratory (LBNL) for many applications, each requiring specific source designs. These uses have ranged from large ion sources for neutral-beam injectors{emdash}several tens of centimeters in size{emdash}to small sources for oil-well logging neutron tubes{emdash}a few centimeters in diameter. The advantages associated with internal antenna, rf-driven ion sources include reliability, long component life, ease of operation, and the ability to generate plasmas free of the impurities commonly found in hot-filament discharge sources. We have investigated and characterized the performance of rf-driven sources with respect to the rf operating frequency and ion source size for hydrogen ion species and current density. Furthermore, we have included in this study the aspects of proper coupling of the rf generator to the antenna through an impedance matching network. Finally, critical issues pertaining to general rf operation including beam extraction, rf shielding, and cooling of transformer cores are discussed.

  15. Multiple species beam production on laser ion source for electron beam ion source in Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, M., E-mail: sekine.m.ae@m.titech.ac.jp [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Meguro, Tokyo (Japan); Riken, Wako, Saitama (Japan); Ikeda, S. [Riken, Wako, Saitama (Japan); Department of Energy Science, Tokyo Institute of Technology, Yokohama, Kanagawa (Japan); Hayashizaki, N. [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, Meguro, Tokyo (Japan); Kanesue, T.; Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2014-02-15

    Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.

  16. Droplet-free high-density metal ion source for plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Keiji [Department of Electrical Engineering, College of Engineering, Chubu University, 1200 Matsumoto, Kasugai, Aichi 487-8501 (Japan)]. E-mail: nakamura@solan.chubu.ac.jp; Yoshinaga, Hiroaki [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Yukimura, Ken [Department of Electrical Engineering, Doshisha University, 1-3 Tatara Miyakodani, Kyotanabe, Kyoto 610-0321 (Japan)

    2006-01-15

    This paper reports on plasma parameters and ion composition of droplet-free Zr ion source for plasma immersion ion implantation and deposition (PIII and D). Zirconium (Zr) ions were obtained by ionizing sputtered Zr atoms in inductively-coupled argon discharge. The characteristics of plasma density, plasma potential and electron temperature were typical ones of such a inductive discharge, and the plasma parameters were not significantly influenced by mixing the sputtered Zr atoms into the plasma. Actually, the main ionic component was still Ar{sup +} ions, and the ion density ratio of [Zr{sup +}]/[Ar{sup +}] was as low as {approx}8%. Increase in sputtering rate of the Zr source will be necessary to improve the ion density ratio.

  17. Two approaches for $H^{-}$ ion production with 245 GHz ion sources

    CERN Document Server

    Gobin, R; Bacal, M; Breton, J; Delferrière, O; Harrault, F; Ivanov, A A; Svarnas, P; Tuske, O

    2006-01-01

    Over the last few years, the accelerator community requested the development of improved negative hydrogen ion sources. For spallation sources, like SNS or ESS, pulsed high intensity H/sup negative ion beams of a few tens of milliamperes, with a duty cycle close to 10%, are required. New facilities like CERN also ask for high performance negative ion beams. Since CEA undertook an electron cyclotron resonance (ECR)-based ion source programme, a European network devoted to high performance negative ion source development has been created. In this group, several laboratories developing 2.45 GHz ECR sources follow different approaches to increase the extracted ion current. At Saclay, with a solenoidal magnetic structure based on coils, close to 3 mA H/sup negative ion beam is now extracted in pulsed mode (2 ms/100 ms). A metallic biased grid separates the plasma bulk from the H/sup negative ion production zone and significantly improves the H/sup negative extracted current. At Ecole Polytechnique, the source Came...

  18. Operation of the CSNS Penning surface H~- ion source

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The accelerator complex of the China Spallation Neutron Source (CSNS) consists of a H- linear accelerator (linac) and a rapid cycling synchrotron (RCS). The linac contains a Penning surface H- ion source. The designed energy and the beam current of the source are 50 keV and 20 mA respectively, with a normalized root mean square (norm. rms.) emittance of 0.2π mm mrad. The manufactures and tests of the discharge chamber are in great progress. The construction of H- ion source test stand has been completed, and the operation of the source is also in progress. Stable H- ion beams with energy of 50 keV and current up to 50 mA are attained. Emittance measurement for the H- beam is being prepared.

  19. Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources

    OpenAIRE

    Indelicato, Paul; Boucard, S.; Covita, D. S.; Gotta, D.; Gruber, A; Hirtl, A.; Fuhrmann, H.; Le Bigot, E.-O.; Schlesser, S.; dos Santos, J. M. F.; Simons, L.M.; Stingelin, L.; Trassinelli, Martino; Veloso, J.; Wasser, A.

    2006-01-01

    Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\\approx 1$~eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with $Z=16$--18. We show how these measurement can test sensitively many-body relativistic calculations or can be used as X-...

  20. Long-pulse operation of an intense negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Takeiri, Yasuhiko; Osakabe, Masaki; Tsumori, Katsuyoshi; Kaneko, Osamu; Oka, Yoshihide; Asano, Eiji; Kawamoto, Toshikazu; Akiyama, Ryuichi; Kuroda, Tsutomu [National Inst. for Fusion Science, Nagoya (Japan)

    1997-02-01

    In the National Institute for Fusion Science, as the heating system for the Large Helical Device (LHD), the negative ion NBI system of 20 MW incident power has been planned, and the development of a large current, large size negative ion source has been advanced. Based on the results obtained so far, the design of the LHD-NBI system was reconsidered, and the specification of the actual negative ion source was decided as 180 KeV-40A. This time, the grounding electrode with heightened heat removal capacity was made, and the long pulse operation was attempted, therefore, its results are reported. The structure of the external magnetic filter type large negative ion source used for the long pulse experiment is explained. In order to form the negative ion beam of long pulses, it is necessary to form stable are discharge plasma for long time, and variable resistors were attached to the output side of arc power sources of respective filament systems. By adjusting the resistors, uniform are discharge was able to be caused for longer than 10 s stably. The results of the long pulse experiment are reported. The dependence of the characteristics of negative ion beam on plasma electrode temperature was small, and the change of the characteristics of negative ion beam due to beam pulse width was not observed. (K.I.)

  1. ECR-Driven Multicusp Volume H- Ion Source

    Science.gov (United States)

    Bacal, M.; Ivanov, A. A.; Rouillé, C.; Svarnas, P.; Béchu, S.; Pelletier, J.

    2005-04-01

    We studied the negative ion current extracted from the plasma created by seven elementary ECR sources, operating at 2.45 GHz, placed in the magnetic multipole chamber "Camembert III". We varied the pressure from 1 to 4 mTorr, with a maximum power of 1 kW and studied the plasma created in this system by measuring the various plasma parameters, including the density and temperature of the negative hydrogen ions. We found that the electron temperature is optimal for negative hydrogen ion production at 9.5 cm from the ECR sources. The tantalum-covered wall surface pollution reduces the extracted negative ion current and enhances the electron current. Tantalum evaporation has a positive effect. The use of a grid and of a collar in front of the plasma electrode did not lead to any enhancement of the extracted negative ion current.

  2. Multicharged iron ions produced by using induction heating vapor source.

    Science.gov (United States)

    Kato, Yushi; Kubo, Takashi; Muramatsu, Masayuki; Tanaka, Kiyokatsu; Kitagawa, Atsushi; Yoshida, Yoshikazu; Asaji, Toyohisa; Sato, Fuminobu; Iida, Toshiyuki

    2008-02-01

    Multiply charged Fe ions are produced from solid pure material in an electron cyclotron resonance (ECR) ion source. We develop an evaporator by using induction heating with an induction coil which is made of bare molybdenum wire partially covered by ceramic beads in vacuum and surrounding and heating directly the pure Fe rod. Heated material has no contact with insulators, so that outgas is minimized. The evaporator is installed around the mirror end plate outside of the ECR plasma with its hole grazing the ECR zone. Helium or argon gas is usually chosen for supporting gas. The multicharged Fe ions up to Fe(13+) are extracted from the opposite side of mirror and against the evaporator, and then multicharged Fe ion beam is formed. We compare production of multicharged iron ions by using this new source with our previous methods.

  3. A New ECR Ion Source for Atomic Physics Research at IMP

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A new Electron Cyclotron Resonance (ECR) ion source (LECR3-Lanzhou Electron Cyclotron Resonance ion source No.3) was constructed this year. The main purpose of this source is to provide highly charged ion beams for atomic physics and surface physics research. The design of this ion source is based on the IMP 14.5 GHz ECR ion source (LECR2-Lanzhou Electron Cyclotron Resonance ion source No.2) with double RF heating

  4. A quadrupole ion trap as low-energy cluster ion beam source

    CERN Document Server

    Uchida, N; Kanayama, T

    2003-01-01

    Kinetic energy distribution of ion beams was measured by a retarding field energy analyzer for a mass-selective cluster ion beam deposition system that uses a quadrupole ion trap as a cluster ion beam source. The results indicated that the system delivers a cluster-ion beam with energy distribution of approx 2 eV, which corresponded well to the calculation results of the trapping potentials in the ion trap. Using this deposition system, mass-selected hydrogenated Si cluster ions Si sub n H sub x sup + were actually deposited on Si(111)-(7x7) surfaces at impact kinetic energy E sub d of 3-30 eV. Observation by using a scanning tunneling microscope (STM) demonstrated that Si sub 6 H sub x sup + cluster ions landed on the surface without decomposition at E sub d =3 eV, while the deposition was destructive at E sub d>=18 eV. (author)

  5. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay.

    Science.gov (United States)

    Delferrière, O; Gobin, R; Harrault, F; Nyckees, S; Sauce, Y; Tuske, O

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  6. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclaya)

    Science.gov (United States)

    Delferrière, O.; Gobin, R.; Harrault, F.; Nyckees, S.; Sauce, Y.; Tuske, O.

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  7. Calcium and lithium ion production for laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, M.; Palm, K.; Stifler, C.; Steski, D.; Ikeda, S.; Kumaki, M.; Kanesue, T.

    2015-08-23

    Calcium and lithium ion beams are required by NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL) to simulate the effects of cosmic radiation. To find out difficulties to provide such high reactive material as laser targets, the both species were experimentally tested. Plate-shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6ns, 1064nm Nd:YAG laser. We found significant oxygen contamination in both the Ca and Li high-charge-state beams due to the rapid oxidation of the surfaces. A large-spot-size, low-power-density laser was then used to analyze the low-charge-state beams without scanning the targets. The low-charge-state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely with a low-power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low-power shot. To measure the rate of oxidation, we shot the low-power laser at the target repeatedly at 10sec, 30sec, 60sec, and 120sec interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

  8. A compact source for bunches of singly charged atomic ions

    Science.gov (United States)

    Murböck, T.; Schmidt, S.; Andelkovic, Z.; Birkl, G.; Nörtershäuser, W.; Vogel, M.

    2016-04-01

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 106 Mg+ ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg+ ions for sympathetic cooling of highly charged ions by laser-cooled 24Mg+.

  9. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy.

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C(5+) ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C(5+) ion beam was got when work gas was CH4 while about 262 eμA of C(5+) ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  10. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Science.gov (United States)

    Cao, Yun; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia

    2014-02-01

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C5+ ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C5+ ion beam was got when work gas was CH4 while about 262 eμA of C5+ ion beam was obtained when work gas was C2H2 gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  11. An all permanent magnet electron cyclotron resonance ion source for heavy ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yun, E-mail: caoyun@impcas.ac.cn; Li, Jia Qing; Sun, Liang Ting; Zhang, Xue Zhen; Feng, Yu Cheng; Wang, Hui; Ma, Bao Hua; Li, Xi Xia [Institute of Modern Physics, CAS, Lanzhou 730000 (China)

    2014-02-15

    A high charge state all permanent Electron Cyclotron Resonance ion source, Lanzhou All Permanent ECR ion source no. 3-LAPECR3, has been successfully built at IMP in 2012, which will serve as the ion injector of the Heavy Ion Medical Machine (HIMM) project. As a commercial device, LAPECR3 features a compact structure, small size, and low cost. According to HIMM scenario more than 100 eμA of C{sup 5+} ion beam should be extracted from the ion source, and the beam emittance better than 75 π*mm*mrad. In recent commissioning, about 120 eμA of C{sup 5+} ion beam was got when work gas was CH{sub 4} while about 262 eμA of C{sup 5+} ion beam was obtained when work gas was C{sub 2}H{sub 2} gas. The design and construction of the ion source and its low-energy transportation beam line, and the preliminary commissioning results will be presented in detail in this paper.

  12. RF Driven Multicusp H- Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Leung, K.N.; DeVries, G.J.; DiVergilio, W.F.; Hamm, R.W.; Hauck, C.A.; Kunkel, W.B.; McDonald, D.S.; Williams, M.D.

    1990-06-01

    An rf driven multicusp source capable of generating 1-ms H{sup -} beam pulses with a repetition rate as high as 150 Hz has been developed. This source can be operated with a filament or other types of starter. There is almost no lifetime limitation and a clean plasma can be maintained for a long period of operation. It is demonstrated that rf power as high as 25 kW could be coupled inductively to the plasma via a glass-coated copper-coil antenna. The extracted H{sup -} current density achieved is about 200 mA/cm{sup 2}.

  13. Development of an rf driven multicusp ion source for nuclear science experiments

    Science.gov (United States)

    Wutte, D.; Freedman, S.; Gough, R.; Lee, Y.; Leitner, M.; Leung, K. N.; Lyneis, C.; Pickard, D. S.; Williams, M. D.; Xie, Z. Q.

    1998-07-01

    A compact 13.56 MHz radio-frequency (rf) driven multicusp ion source is under development at Lawrence Berkeley National Laboratory (LBNL) for radioactive ion beam applications. In this paper we describe the ion source design and the general ion source performance using H 2, Ar, Xe gas and a 90% Ar/10% CO gas mixture for generating the discharge plasma. The following ion source characteristics have been analyzed: extractable ion current, ion species distributions, ionization efficiency for nobel gases, axial energy spread and ion beam emittance measurements. This ion source can generate ion current densities of approximately 60 mA/cm 2.

  14. Emission characteristics of AuSiBe field ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Drandarov, N.; Georgieva, St.; Nikolov, B.; Donchev, T. (Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. po Elektronika)

    A ribbon type AuSiBe alloy field ion source, which combines the advantages of both hairpin type sources and reservoir type sources, has been constructed. The current-voltage characteristics of this source have been investigated. Hysteresis and four differentiated emission regions have been observed for them. By means of scanning electronic microscopy, it has been established that this complicated behaviour of the I-V curves and the angular distribution of the extracted ions are associated with the shape of the emitting surface. The mass spectrum of the emitted ions has been determined by means of an E x B mass filter. Considerable emission of Au[sup +], AuBe[sub 3][sup 2+], Si[sup 2+], Be[sup 2+], AuBe[sub 3][sup +], Be[sup +], Si[sup +], and Au[sup 2+] has been observed. (author).

  15. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; O’Neil, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Steyaert, D; Thaus, N; Hatayama, A; Nishida, K; Shibata, T; Yamamot, T; Otha, M

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the LEBT, RFQ and chopper of Linac4.

  16. Development of multiampere negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, J.; Hershcovitch, A.; Prelec, K.; Sluyters, T.

    1981-01-01

    The Neutral Beam Development Group at BNL is developing H-/D- surface plasma sources as part of a high energy neutral beam injector. Uncooled Penning and magnetron sources have operated at a maximum beam current of 1 A (10 ms pulses, Mk III) and a maximum pulse length of 200 ms (0.3 A, Mk IV). A magnetron source with focusing grooves on the cathode and an asymmetric anode-cathode geometry operates at a power efficiency of 8 kW/A and a 6% gas efficiency. As the next step, a water cooled magnetron, designed to give a steady state beam of 1 to 2 A, has been constructed. Experiments are in progress to test a modification of the magnetron which may significantly improve its performance. By injecting a sheet of plasma, produced by a highly gas efficient hollow cathode discharge, into a magnetron type anode-cathode geometry, we anticipate a reduction of the source operating pressure by at least three orders of magnitude. Initial experiments have given indications of H/sup -/ production. The next plasma injection experiment is designed to give a steady state beam of approx. = 1 A.

  17. Development of C⁶⁺ laser ion source and RFQ linac for carbon ion radiotherapy.

    Science.gov (United States)

    Sako, T; Yamaguchi, A; Sato, K; Goto, A; Iwai, T; Nayuki, T; Nemoto, K; Kayama, T; Takeuchi, T

    2016-02-01

    A prototype C(6+) injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  18. Development of C6+ laser ion source and RFQ linac for carbon ion radiotherapy

    Science.gov (United States)

    Sako, T.; Yamaguchi, A.; Sato, K.; Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T.; Takeuchi, T.

    2016-02-01

    A prototype C6+ injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  19. Development of C{sup 6+} laser ion source and RFQ linac for carbon ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sako, T., E-mail: takayuki1.sako@toshiba.co.jp; Yamaguchi, A.; Sato, K. [Toshiba Corporation, Yokohama 235-8522 (Japan); Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T. [Cancer Research Center, Yamagata University Faculty of Medicine, Yamagata 990-9585 (Japan); Takeuchi, T. [Accelerator Engineering Corporation, Chiba 263-0043 (Japan)

    2016-02-15

    A prototype C{sup 6+} injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  20. Review of MEVVA ion source performance for accelerator injection

    Energy Technology Data Exchange (ETDEWEB)

    Brown, I.G.; Godechot, X. (Lawrence Berkeley Lab., CA (USA)); Spaedtke, P.; Emig, H.; Rueck, D.M.; Wolf, B.H. (Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany, F.R.))

    1991-05-01

    The Mevva (metal vapor vacuum arc) ion source provides high current beams of multiply-charged metal ions suitable for use in heavy ion synchrotrons as well as for metallurgical ion implantation. Pulsed beam currents of up to several amperes can be produced at ion energies of up to several hundred keV. Operation has been demonstrate for 48 metallic ion species: Li, C, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ge, Sr, Y, Zr, Nb, Mo, Pd, Ag, Cd, In, Sn, Ba, La, Ce, Pr, Nd, Sm, Gd, Dy, Ho, Er, Yb, Hf, Ta, W, Ir, Pt, Au, Pb, Bi, Th and U. When the source is operated optimally the rms fractional beam noise can be as low as 7% of the mean beam current; and when properly triggered the source operates reliably and reproducibly for many tens of thousands of pulses without failure. In this paper we review the source performance referred specifically to its use for synchrotron injection. 15 refs., 3 figs.

  1. Overview of ion source characterization diagnostics in INTF

    Science.gov (United States)

    Bandyopadhyay, M.; Sudhir, Dass; Bhuyan, M.; Soni, J.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A.

    2016-02-01

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  2. Modeling of negative ion transport in a plasma source

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-08-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3-D motion equation, while the atomic processes of destruction, of elastic collision H-/H+ and of charge exchange H-/H0 are handled at each time step by a Monte-Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided if they are produced at a distance lower than 2 cm from the plasma grid in the case of «volume production» (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  3. Overview of ion source characterization diagnostics in INTF

    Energy Technology Data Exchange (ETDEWEB)

    Bandyopadhyay, M., E-mail: mainak@iter-india.org; Sudhir, Dass; Bhuyan, M.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A. [ITER-India, Institute for Plasma Research, A-29 GIDC, Sector-25, Gandhinagar, Gujarat 382016 (India); Soni, J. [Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382 428 (India)

    2016-02-15

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  4. Some estimates of the virtual source size of a liquid metal ion source

    Energy Technology Data Exchange (ETDEWEB)

    Georgieva, S.; Vichev, R.G.; Drandarov, N. (Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. po Elektronika)

    A Monte Carlo computer code simulating the trajectories of ions emitted from a liquid metal ion source (LMIS) is developed. The electric field of the tip is taken to be that created by a sphere-on-orthogonal cone. The ions are emitted normal to the surface with an initial energy of 1 eV. A Poisson distribution is used to describe the time dependence of their emission process. Ion trajectories are followed and the virtual source size and energy spectra are evaluated for three reference planes normal to the emitter axis. The obtained results are compared with the experimentally measured values. (author).

  5. 22 A beam production of the uniform negative ions in the JT-60 negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Masafumi, E-mail: yoshida.masafumi@jaea.go.jp [Japan Atomic Energy Agency, 801-1, Mukoyama, Naka 311-0193 (Japan); Hanada, Masaya; Kojima, Atsushi; Kashiwagi, Mieko [Japan Atomic Energy Agency, 801-1, Mukoyama, Naka 311-0193 (Japan); Grisham, Larry R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Hatayama, Akiyoshi; Shibata, Takanori; Yamamoto, Takashi [Faculty of Science and Technology, Keio University, 3-14-1, Hiyoshi, Kohoku-ku, Yokohama 223-8511 (Japan); Akino, Noboru; Endo, Yasuei; Komata, Masao; Mogaki, Kazuhiko; Nemoto, Shuji; Ohzeki, Masahiro; Seki, Norikazu; Sasaki, Shunichi; Shimizu, Tatsuo; Terunuma, Yuto [Japan Atomic Energy Agency, 801-1, Mukoyama, Naka 311-0193 (Japan)

    2015-10-15

    Highlights: • In order to improve a uniformity of the negative ion beam and produce high current negative ion beam in the JT-60 negative ion source, a tent-shaped filter is applied. • Beam uniformity is improved from 68% to 83% over an area of the whole extraction area of 450 x 1100 mm{sup 2}. • The improvement of the beam uniformity leads to the production of 32 A H{sup −} ion beams with the whole extraction area. - Abstract: In order to improve the spatial uniformity of the negative ion beam and to produce high current negative ion beams in a large negative ion source, a magnetic field configuration is modified from an original transverse filter to a tent-shaped filter, in combination with reducing the magnetic field strength in the JT-60 negative ion source. As a result, the beam uniformity is improved from 68% to 83% over an area of the whole extraction area of 450 × 1100 mm{sup 2}. The improvement of the beam uniformity leads to the production of 32 A H{sup −} ion beams with the whole extraction area. The obtained beam current fulfills the requirement for JT-60SA.

  6. Development of a compact ECR ion source for various ion production

    Energy Technology Data Exchange (ETDEWEB)

    Muramatsu, M., E-mail: m-mura@nirs.go.jp; Hojo, S.; Iwata, Y.; Katagiri, K.; Sakamoto, Y.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Takahashi, N. [Sumitomo Heavy Industries, Ltd., 19 Natsushima, Yokosuka, Kanagawa 237-8555 (Japan); Sasaki, N.; Fukushima, K.; Takahashi, K.; Suzuki, T.; Sasano, T. [Accelerator Engineering Corporation, 3-8-5 Konakadai, Inage, Chiba 263-0043 (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, 2100 Kujirai, Kawagoe-shi, Saitama 350-8585 (Japan); Hagino, S.; Nishiokada, T.; Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

  7. Characterization of electron temperature by simulating a multicusp ion source

    Science.gov (United States)

    Yeon, Yeong Heum; Ghergherehchi, Mitra; Kim, Sang Bum; Jun, Woo Jung; Lee, Jong Chul; Mohamed Gad, Khaled Mohamed; Namgoong, Ho; Chai, Jong Seo

    2016-12-01

    Multicusp ion sources are used in cyclotrons and linear accelerators to produce high beam currents. The structure of a multicusp ion source consists of permanent magnets, filaments, and an anode body. The configuration of the array of permanent magnets, discharge voltage of the plasma, extraction bias voltage, and structure of the multicusp ion source body decide the quality of the beam. The electrons are emitted from the filament by thermionic emission. The emission current can be calculated from thermal information pertaining to the filament, and from the applied voltage and current. The electron trajectories were calculated using CST Particle Studio to optimize the plasma. The array configuration of the permanent magnets decides the magnetic field inside the ion source. The extraction bias voltage and the structure of the multicusp ion source body decide the electric field. Optimization of the electromagnetic field was performed with these factors. CST Particle Studio was used to calculate the electron temperature with a varying permanent magnet array. Four types of permanent magnet array were simulated to optimize the electron temperature. It was found that a 2-layer full line cusp field (with inverse field) produced the best electron temperature control behavior.

  8. High brilliance multicusp ion source for hydrogen microscopy at SNAKE

    Energy Technology Data Exchange (ETDEWEB)

    Moser, M., E-mail: marcus.moser@unibw.de [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Reichart, P. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Carli, W. [Maier-Leibniz-Laboraturium der LMU und TU Muenchen, 85478 Garching (Germany); Greubel, C.; Peeper, K. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Hartung, P. [Maier-Leibniz-Laboraturium der LMU und TU Muenchen, 85478 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Institut fuer Angewandte Physik und Messtechnik, LRT2, Department fuer Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany)

    2012-02-15

    In order to improve the lateral resolution of the 3D hydrogen microscopy by proton-proton scattering at the Munich microprobe SNAKE, we have installed a new multicusp ion source for negative hydrogen ions manufactured by HVEE at the Munich 14 MV tandem accelerator that boosts the proton beam brilliance with the potential to reduce the beam diameter at the focal plane of SNAKE. We measured a beam brilliance B = 27 A m{sup -2} rad{sup -2} eV{sup -1} directly behind the ion source that is at the space charge limit for conventional ion sources. After preacceleration to in total 180 keV beam energy we measure a slightly reduced beam brilliance of B = 10 {mu}A mm{sup -2} mrad{sup -2} MeV{sup -1}. For injection into the tandem accelerator, the extracted H{sup -}-current of the multicusp source of 1 mA is reduced to about 10 {mu}A because of radiation safety regulations and heating problems at the object slits of SNAKE. Due to beam oscillations and influences of the terminal stripper of the tandem we measured a reduced beam brilliance of 0.8 {mu}A mm{sup -2} mrad{sup -2} MeV{sup -1} in front of SNAKE at 25 MeV but still being nearly 10 times larger than measured with any other ion source.

  9. High brilliance multicusp ion source for hydrogen microscopy at SNAKE

    Science.gov (United States)

    Moser, M.; Reichart, P.; Carli, W.; Greubel, C.; Peeper, K.; Hartung, P.; Dollinger, G.

    2012-02-01

    In order to improve the lateral resolution of the 3D hydrogen microscopy by proton-proton scattering at the Munich microprobe SNAKE, we have installed a new multicusp ion source for negative hydrogen ions manufactured by HVEE at the Munich 14 MV tandem accelerator that boosts the proton beam brilliance with the potential to reduce the beam diameter at the focal plane of SNAKE. We measured a beam brilliance B = 27 A m -2 rad -2 eV -1 directly behind the ion source that is at the space charge limit for conventional ion sources. After preacceleration to in total 180 keV beam energy we measure a slightly reduced beam brilliance of B = 10 μA mm -2 mrad -2 MeV -1. For injection into the tandem accelerator, the extracted H --current of the multicusp source of 1 mA is reduced to about 10 μA because of radiation safety regulations and heating problems at the object slits of SNAKE. Due to beam oscillations and influences of the terminal stripper of the tandem we measured a reduced beam brilliance of 0.8 μA mm -2 mrad -2 MeV -1 in front of SNAKE at 25 MeV but still being nearly 10 times larger than measured with any other ion source.

  10. Low fragment polyatomic molecular ion source by using permanent magnets.

    Science.gov (United States)

    Takeuchi, Mitsuaki; Hayashi, Kyouhei; Imanaka, Kousuke; Ryuto, Hiromichi; Takaoka, Gikan H

    2014-02-01

    Electron-ionization-type polyatomic molecular ion source with low fragment was developed by using a pair of ring-shaped Sm-Co magnets. The magnets were placed forward and backward side of ionization part to confine electrons extracted from a thermionic cathode. Calculated electron trajectory of the developed ion source was 20 times longer than that of an ordinary outer filament configuration that has no magnetic confinement. Mass spectra of the molecular ions generated from n-tetradecane (C14H30) gas exhibited 4 times larger intensity than that of the ordinary configuration in a range of mass/charge from 93 to 210 u. This indicates that suppression of fragment ion was obtained by increase of low energy electrons resulted from the electron confinement.

  11. The microbial fermentation characteristics depend on both carbohydrate source and heat processing: a model experiment with ileo-cannulated pigs

    DEFF Research Database (Denmark)

    Nielsen, Tina Skau; Jørgensen, Henry Johs. Høgh; Knudsen, Knud Erik Bach

    2017-01-01

    The effects of carbohydrate (CHO) source and processing (extrusion cooking) on large intestinal fermentation products were studied in ileo-cannulated pigs as a model for humans. Pigs were fed diets containing barley, pea or a mixture of potato starch:wheat bran (PSWB) either raw or extrusion cooked....... Extrusion cooking reduced the amount of starch fermented in the large intestine by 52–96% depending on the CHO source and the total pool of butyrate in the distal small intestine + large intestine by on average 60% across diets. Overall, extrusion cooking caused a shift in the composition of short...

  12. Shutterless ion mobility spectrometer with fast pulsed electron source

    Science.gov (United States)

    Bunert, E.; Heptner, A.; Reinecke, T.; Kirk, A. T.; Zimmermann, S.

    2017-02-01

    Ion mobility spectrometers (IMS) are devices for fast and very sensitive trace gas analysis. The measuring principle is based on an initial ionization process of the target analyte. Most IMS employ radioactive electron sources, such as 63Ni or 3H. These radioactive materials have the disadvantage of legal restrictions and the electron emission has a predetermined intensity and cannot be controlled or disabled. In this work, we replaced the 3H source of our IMS with 100 mm drift tube length with our nonradioactive electron source, which generates comparable spectra to the 3H source. An advantage of our emission current controlled nonradioactive electron source is that it can operate in a fast pulsed mode with high electron intensities. By optimizing the geometric parameters and developing fast control electronics, we can achieve very short electron emission pulses for ionization with high intensities and an adjustable pulse width of down to a few nanoseconds. This results in small ion packets at simultaneously high ion densities, which are subsequently separated in the drift tube. Normally, the required small ion packet is generated by a complex ion shutter mechanism. By omitting the additional reaction chamber, the ion packet can be generated directly at the beginning of the drift tube by our pulsed nonradioactive electron source with only slight reduction in resolving power. Thus, the complex and costly shutter mechanism and its electronics can also be omitted, which leads to a simple low-cost IMS-system with a pulsed nonradioactive electron source and a resolving power of 90.

  13. Scanning microbeam using a liquid metal ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ishitani, T.; Tamura, H.; Todokoro, H.

    1982-01-01

    A scanning ion microprobe system using a liquid-Ga ion source and a voltage-asymmetric three-electrode lens is developed. It produces 2--20 keV Ga/sup +/ beams of 0.1--5 ..mu..m diameter with 20 pA--8 nA current. Beam sizes are directly measured by a combined sharp-edge and Faraday cup mehtod. This optical system is well suited for variable energy microprobe applications.

  14. Alternative modeling methods for plasma-based Rf ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Veitzer, Seth A., E-mail: veitzer@txcorp.com; Kundrapu, Madhusudhan, E-mail: madhusnk@txcorp.com; Stoltz, Peter H., E-mail: phstoltz@txcorp.com; Beckwith, Kristian R. C., E-mail: beckwith@txcorp.com [Tech-X Corporation, Boulder, Colorado 80303 (United States)

    2016-02-15

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two

  15. Alternative modeling methods for plasma-based Rf ion sources

    Science.gov (United States)

    Veitzer, Seth A.; Kundrapu, Madhusudhan; Stoltz, Peter H.; Beckwith, Kristian R. C.

    2016-02-01

    Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H- source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H- ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models

  16. Development of a low energy ion source with multicapillary anode

    Science.gov (United States)

    Ogawa, Soichi; Okamoto, Akio; Takiguchi, Katsumi; Yoshitake, Masaaki; Nosaka, Toshikazu; Fukui, Shigeo; Ueno, Tsutomu

    1989-02-01

    A new type of hot cathode ion source which has a multicapillary anode and a discharge stabilizer electrode has been developed. There are two special features in this ion source. The gaseous flow is intense and of the collimated beam type, because it is introduced through the multicapillary anode. A high ion current density ( > 5 mA/cm 2) can be obtained because discharge in high vacuum can continue with the help of the stabilizer electrode. At a stabilizer voltage ( Vs) of 50 V, ion current densities of 2.2 and 6.1 mA/cm 2 were obtained at acceleration voltages ( Vacc) of 20 and 200 V, respectively. The ion energy was dependent on Vd, and the full width at half maximum (FWHM) of its distribution was less than 15 eV. Cu films were etched by this ion source. The etching rate ( Er) was 150 Å/min at Vacc = 100 V. The relationship between the etching rate and Vacc was represented by Er ∝ ( Vacc) α. The values of α were 2.0 in the region of Vacc ≤ 100 V and 1.0 for Vacc ≥ 100 V.

  17. Shunting arc plasma source for pure carbon ion beam.

    Science.gov (United States)

    Koguchi, H; Sakakita, H; Kiyama, S; Shimada, T; Sato, Y; Hirano, Y

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA∕mm(2) at the peak of the pulse.

  18. Hollow metal target magnetron sputter type radio frequency ion source

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, N., E-mail: mwada@mail.doshisha.ac.jp; Kasuya, T.; Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyoto 610–0321 (Japan); Tsubouchi, N. [Kansai Institute, Advanced Industrial Science and Technology, Osaka 563–8577 (Japan)

    2014-02-15

    A 70 mm diameter 70 mm long compact ion source equipped with a hollow sputtering target has been designed and tested. The hollow sputtering target serves as the radio frequency (RF) plasma excitation electrode at 13.56 MHz. A stable beam of Cu{sup +} has been extracted when Ar was used as the discharge support gas. In the extracted beam, Cu{sup +} had occupied more than 85% of the total ion current. Further increase in Cu{sup +} ions in the beam is anticipated by increasing the RF power and Ar pressure.

  19. Shunting arc plasma source for pure carbon ion beama)

    Science.gov (United States)

    Koguchi, H.; Sakakita, H.; Kiyama, S.; Shimada, T.; Sato, Y.; Hirano, Y.

    2012-02-01

    A plasma source is developed using a coaxial shunting arc plasma gun to extract a pure carbon ion beam. The pure carbon ion beam is a new type of deposition system for diamond and other carbon materials. Our plasma device generates pure carbon plasma from solid-state carbon material without using a hydrocarbon gas such as methane gas, and the plasma does not contain any hydrogen. The ion saturation current of the discharge measured by a double probe is about 0.2 mA/mm2 at the peak of the pulse.

  20. Plasma and Ion Sources in Large Area Coatings: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2005-02-28

    Efficient deposition of high-quality coatings often requires controlled application of excited or ionized particles. These particles are either condensing (film-forming) or assisting by providing energy and momentum to the film growth process, resulting in densification, sputtering/etching, modification of stress, roughness, texture, etc. In this review, the technical means are surveyed enabling large area application of ions and plasmas, with ion energies ranging from a few eV to a few keV. Both semiconductortype large area (single wafer or batch processing with {approx} 1000 cm{sup 2}) and in-line web and glass-coating-type large area (> 10{sup 7} m{sup 2} annually) are considered. Characteristics and differences between plasma and ion sources are explained. The latter include gridded and gridless sources. Many examples are given, including sources based on DC, RF, and microwave discharges, some with special geometries like hollow cathodes and E x B configurations.

  1. Multicusp type Electron Cyclotron Resonance ion source for plasma processing

    Energy Technology Data Exchange (ETDEWEB)

    Amemiya, Hiroshi; Shigueoka, Yoshyuki (Institute of Physical and Chemical Research, Wako, Saitama (Japan)); Ishii, Shigeyuki

    1991-02-01

    A multi-cusp type ECR (electron cyclotron resonance) ion source is built with use of SmCo magnets and 2.45 GHz-TE{sub 11} circular mode microwave. The ion source is operated at pressures from 10{sup -4} to 10{sup -3} Torr with the input microwave power from 100 to 400 W. In hydrogen, the current density of H{sup +} is higher than those of H{sub 2}{sup +} and H{sub 3}{sup +}. The dependence of the fraction of each ion species on the power and pressure is measured and explained by rate equations. The source is operated also in other gases. Mass spectra in He, N{sub 2}, O{sub 2}, Ar and CH{sub 4} are shown together with the pressure and power dependences. Multicharged state of up to 3 has been obtained. (author).

  2. Estimate of cusp loss width in multicusp negative ion source

    Science.gov (United States)

    Morishita, T.; Ogasawara, M.; Hatayama, A.

    1998-02-01

    Expression of cusp loss width derived by Bosch and Merlino is applied to JAERI's Kamaboko source. The width is related to the ambipolar diffusion coefficient across the cusp magnetic field. Electron-ion collision is found 1.2-7.4 times larger as compared with electron-neutral collision. Averaged cusp magnetic field in the diffusion coefficient is taken as a parameter in the simulation code for Kamaboko source. When the averaged magnetic field is 48 G, simulation results agree well with JAERI's experiment in a wide range of pressure and arc power variation. The value of 48 G is reasonable from the consideration of confining the equation of ion source plasma. The obtained width is about 10 times the value evaluated by two times ion Larmor radius on the surface of cusp magnet.

  3. Design and development of the CSNS ion source control system

    CERN Document Server

    Yan-Hua, Lu; Hua-Fu, Ouyang

    2013-01-01

    After the CSNS ion source test stand has been stably working for years, an online control system for CSNS ion source aiming to be more stable and reliable is now under development. F3RP61-2L, a new PLC CPU module under Linux system, is introduced to the system as an IOC, to function together with the I/O modules of FA-M3 PLC on the PLC-bus. The adoption of the new IOC not only simplifies the architecture of the control system, but also improves the data transmission speed. In this paper, the design and development of the supervisory and control system for CSNS ion source are described.

  4. Surface modeling for optical fabrication with linear ion source

    CERN Document Server

    Wu, Lixiang; Shao, Jianda

    2016-01-01

    We present a concept of surface decomposition extended from double Fourier series to nonnegative sinusoidal wave surfaces, on the basis of which linear ion sources apply to the ultra-precision fabrication of complex surfaces and diffractive optics. It is the first time that we have a surface descriptor for building a relationship between the fabrication process of optical surfaces and the surface characterization based on PSD analysis, which akin to Zernike polynomials used for mapping the relationship between surface errors and Seidel aberrations. Also, we demonstrate that the one-dimensional scanning of linear ion source is applicable to the removal of surface errors caused by small-tool polishing in raster scan mode as well as the fabrication of beam sampling grating of high diffractive uniformity without a post-processing procedure. The simulation results show that, in theory, optical fabrication with linear ion source is feasible and even of higher output efficiency compared with the conventional approac...

  5. Design and development of the CSNS ion source control system

    Institute of Scientific and Technical Information of China (English)

    LU Yan-Hua; LI Gang; OUYANG Hua-Fu

    2013-01-01

    Now that the CSNS ion source test stand has been stably working for years,an online control system for the CSNS ion source which aims to be more stable and reliable is now under development.F3RP61-2L,a new PLC CPU module running an embedded Linux system,is introduced to the system as an IOC,to function together with the I/O modules of FA-M3 PLC on the PLC-bus.The adoption of the new IOC not only simplifies the architecture of the control system,but also improves the data transmission speed.In this paper,the design and development of the supervisory and control system for the CSNS ion source are described.

  6. Gridless, very low energy, high-current, gaseous ion source

    Energy Technology Data Exchange (ETDEWEB)

    Vizir, A. V.; Oks, E. M. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation); State University of Control Systems and Radioelectronics, Tomsk 634050 (Russian Federation); Shandrikov, M. V.; Yushkov, G. Yu. [High Current Electronics Institute, Russian Academy of Sciences, Tomsk 634055 (Russian Federation)

    2010-02-15

    We have made and tested a very low energy gaseous ion source in which the plasma is established by a gaseous discharge with electron injection in an axially diverging magnetic field. A constricted arc with hidden cathode spot is used as the electron emitter (first stage of the discharge). The electron flux so formed is filtered by a judiciously shaped electrode to remove macroparticles (cathode debris from the cathode spot) from the cathode material as well as atoms and ions. The anode of the emitter discharge is a mesh, which also serves as cathode of the second stage of the discharge, providing a high electron current that is injected into the magnetic field region where the operating gas is efficiently ionized. In this discharge configuration, an electric field is formed in the ion generation region, accelerating gas ions to energy of several eV in a direction away from the source, without the use of a gridded acceleration system. Our measurements indicate that an argon ion beam is formed with an energy of several eV and current up to 2.5 A. The discharge voltage is kept at less than 20 V, to keep below ion sputtering threshold for cathode material, a feature which along with filtering of the injected electron flow, results in extremely low contamination of the generated ion flow.

  7. Ion energy spread and current measurements of the rf-driven multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.; Gough, R.A.; Kunkel, W.B.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Sun, L.; Vujic, J.; Williams, M.D.; Wutte, D. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    1997-03-01

    Axial energy spread and useful beam current of positive ion beams have been carried out using a radio frequency (rf)-driven multicusp ion source. Operating the source with a 13.56 MHz induction discharge, the axial energy spread is found to be approximately 3.2 eV. The extractable beam current of the rf-driven source is found to be comparable to that of filament-discharge sources. With a 0.6 mm diameter extraction aperture, a positive hydrogen ion beam current density of 80 mA/cm{sup 2} can be obtained at a rf input power of 2.5 kW. The expected source lifetime is much longer than that of filament discharges. {copyright} {ital 1997 American Institute of Physics.}

  8. Ion energy spread and current measurements of the rf-driven multicusp ion source

    Science.gov (United States)

    Lee, Y.; Gough, R. A.; Kunkel, W. B.; Leung, K. N.; Perkins, L. T.; Pickard, D. S.; Sun, L.; Vujic, J.; Williams, M. D.; Wutte, D.

    1997-03-01

    Axial energy spread and useful beam current of positive ion beams have been carried out using a radio frequency (rf)-driven multicusp ion source. Operating the source with a 13.56 MHz induction discharge, the axial energy spread is found to be approximately 3.2 eV. The extractable beam current of the rf-driven source is found to be comparable to that of filament-discharge sources. With a 0.6 mm diameter extraction aperture, a positive hydrogen ion beam current density of 80 mA/cm2 can be obtained at a rf input power of 2.5 kW. The expected source lifetime is much longer than that of filament discharges.

  9. Analysis of the ion beam obtained from a small multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Langbein, K.; Riehl, G.; Klein, H. (Insitut fuer Angewandte Physik, Universitaet Frankfurt, Robert-Mayer-Strasse 2-4, D-6000 Frankurt a. M., Federal Republic of Germany (DE)); Walther, S.R.; Keller, R. (Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720 (USA))

    1990-01-01

    The small multicusp ion source developed at Lawrence Berkeley Laboratory (LBL) has been equipped with a low voltage ratio, single aperture extraction system. The influence of the potential of the plasma electrode and of a dipole filter field on the beam emittance are measured. A simple method to reduce hash is suggested. The aim of these investigations is to produce nitrogen ion beams with a high atomic ion fraction and a low emittance as required for a RFQ-accelerator, which will be built for ion implantation.

  10. Production of a highly charged uranium ion beam with RIKEN superconducting electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Higurashi, Y.; Ohnishi, J.; Nakagawa, T.; Haba, H.; Fujimaki, M.; Komiyama, M.; Kamigaito, O. [RIKEN Nishina Center, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); Tamura, M.; Aihara, T.; Uchiyama, A. [SHI Accelerator Service Ltd., 1-17-6 Osaki, Shinagawa, Tokyo 141-0032 (Japan)

    2012-02-15

    A highly charged uranium (U) ion beam is produced from the RIKEN superconducting electron cyclotron resonance ion source using 18 and 28 GHz microwaves. The sputtering method is used to produce this U ion beam. The beam intensity is strongly dependent on the rod position and sputtering voltage. We observe that the emittance of U{sup 35+} for 28 GHz microwaves is almost the same as that for 18 GHz microwaves. It seems that the beam intensity of U ions produced using 28 GHz microwaves is higher than that produced using 18 GHz microwaves at the same Radio Frequency (RF) power.

  11. H- Ion Sources For CERN’s Linac4

    CERN Document Server

    Lettry, J; Coutron, Y; Chaudeta, E; Dallocchio, A; Gil Flores, J; Hansen, J; Mahner, E; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; O’Neil, M; Paoluzzi, M; Pasquino, C; Pereira, H; Sanchez Arias, J; Schmitzer, C; Scrivens, R; Steyaert, D

    2013-01-01

    The specifications set to the Linac4 ion source are: H- ion pulses of 0.5 ms duration, 80 mA intensity and 45 keV energy within a normalized emittance of 0.25 mmmrad RMS at a repetition rate of 2 Hz. In 2010, during the commissioning of a prototype based on H- production from the plasma volume, it was observed that the powerful co-extracted electron beam inherent to this type of ion source could destroy its electron beam dump well before reaching nominal parameters. However, the same source was able to provide 80 mA of protons mixed with a small fraction of H2+ and H3+ molecular ions. The commissioning of the radio frequency quadrupole accelerator (RFQ), beam chopper and H- beam diagnostics of the Linac4 are scheduled for 2012 and its final installation in the underground building is to start in 2013. Therefore, a crash program was launched in 2010 and reviewed in 2011 aiming at keeping the original Linac4 schedule with the following deliverables: Design and production of a volume ion source prototype suitabl...

  12. Modeling of negative ion transport in a plasma source (invited)

    Science.gov (United States)

    Riz, David; Paméla, Jérôme

    1998-02-01

    A code called NIETZSCHE has been developed to simulate the negative ion transport in a plasma source, from their birth place to the extraction holes. The H-/D- trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collision with H+/D+ and of charge exchange with H0/D0 are handled at each time step by a Monte Carlo procedure. This code can be used to calculate the extraction probability of a negative ion produced at any location inside the source. Calculations performed with NIETZSCHE have been allowed to explain, either quantitatively or qualitatively, several phenomena observed in negative ion sources, such as the isotopic H-/D- effect, and the influence of the plasma grid bias or of the magnetic filter on the negative ion extraction. The code has also shown that, in the type of sources contemplated for ITER, which operate at large arc power densities (>1 W cm-3), negative ions can reach the extraction region provided they are produced at a distance lower than 2 cm from the plasma grid in the case of volume production (dissociative attachment processes), or if they are produced at the plasma grid surface, in the vicinity of the extraction holes.

  13. The Leuven isotope separator on-line laser ion source

    CERN Document Server

    Kudryavtsev, Y; Franchoo, S; Huyse, M; Gentens, J; Kruglov, K; Müller, W F; Prasad, N V S; Raabe, R; Reusen, I; Van den Bergh, P; Van Duppen, P; Van Roosbroeck, J; Vermeeren, L; Weissman, L

    2002-01-01

    An element-selective laser ion source has been used to produce beams of exotic radioactive nuclei and to study their decay properties. The operational principle of the ion source is based on selective resonant laser ionization of nuclear reaction products thermalized and neutralized in a noble gas at high pressure. The ion source has been installed at the Leuven Isotope Separator On-Line (LISOL), which is coupled on-line to the cyclotron accelerator at Louvain-la-Neuve. sup 5 sup 4 sup , sup 5 sup 5 Ni and sup 5 sup 4 sup , sup 5 sup 5 Co isotopes were produced in light-ion-induced fusion reactions. Exotic nickel, cobalt and copper nuclei were produced in proton-induced fission of sup 2 sup 3 sup 8 U. The b decay of the sup 6 sup 8 sup - sup 7 sup 4 Ni, sup 6 sup 7 sup - sup 7 sup 0 Co, sup 7 sup 0 sup - sup 7 sup 5 Cu and sup 1 sup 1 sup 0 sup - sup 1 sup 1 sup 4 Rh isotopes has been studied by means of beta-gamma and gamma-gamma spectroscopy. Recently, the laser ion source has been used to produce neutron-d...

  14. Application of synchrotron source based DEI method in guinea pig cochleae imaging

    Institute of Scientific and Technical Information of China (English)

    YIN Hongxia; LIU Bo; GAO Xin; GAO Xiulai; LUO Shuqian

    2007-01-01

    Hard X-ray diffraction enhanced imaging (DEI), which is based on a synchrotron source and monochromator-analyzercrystal system, is an effective method for imaging X-ray phase shift. Utilizing an analyzer crystal with high angular sensitivity of micro-radian, DEI can measure the transmitted, refracted and scattered X-rays when projecting onto a sample. It dramatically improves the contrast and spatial resolution of the resultant images. At the topography station of Beijing Synchrotron Radiation Facilities (BSRF), we implemented DEI method in guinea pig cochleae imaging and acquired a series of DEI images. Based on these images, the apparent absorption and refraction images were calculated. The DEI images revealed the holistic spiral structures and inner details of guinea pig cochleae clearly, even including the structures at the cellular level, such as the static cilia of hairy cells and the limbus of Hansen cell. Due to the advanrages of high contrast, high spatial resolution and distinct edge-enhanced effect, DEI method promises extensive applications in biology,medicine and clinic in the near future.

  15. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yushi, E-mail: kato@eei.eng.osaka-u.ac.jp; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu [Division of Electrical, Electronic and Information Engineering, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita-shi, Osaka 565-0871 (Japan)

    2016-02-15

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  16. Hindgut fermentation in pigs induced by diets with different sources of starch

    Directory of Open Access Journals (Sweden)

    J. Suárez-Belloch

    2013-06-01

    Full Text Available A proportion of dietary starch reaches the hindgut, being fermented there. The characteristics of in vitro caecal fermentation and microbial community in pigs given different sources of starch were studied. Twenty-four Duroc × (Landrace × Large White gilts given diets based on barley (B, broken rice (R, maize (M or peas (P (n=6 for five weeks were slaughtered with 93.6 ± 6.41 kg. No differences (p>0.10 were recorded in caecal pH, total short chain fatty acid (SCFA and total bacterial concentration, nor in in vitro gas production from caecal contents, indicating the lack of a quantitative dietary effect on caecal environment. This could be partly due to the length of fasting time before slaughter (around 10 h. Molar SCFA proportions did not differ among diets; however, relative proportion of Lactobacillus sobrius/amylovorus as the species-type in starch digestion in hindgut of pigs, was highest with P diet (p = 0.010, and gas production from potato starch as substrate with P diet was highest at 2 h incubation (p = 0.012, and higher than B and R diets at 4 (p = 0.055 and 6 (p = 0.10 h incubation. Caecal bacterial biodiversity was higher for M and R diets than for P and B diets (Shannon index, p = 0.003. Sources of resistant or slowly digestible starch such as peas promote a microbial community with a different profile and higher capacity to ferment the starch arriving to the organ than other sources which are mostly digested in the small gut.

  17. Ion beams in SEM: An experiment towards a high brightness low energy spread electron impact gas ion source

    NARCIS (Netherlands)

    Jun, D.S.; Kutchoukov, V.G.; Kruit, P.

    2011-01-01

    A next generation ion source suitable for both high resolution focused ion beam milling and imaging applications is currently being developed. The new ion source relies on a method of which positively charged ions are extracted from a miniaturized gas chamber where neutral gas atoms become ionized b

  18. ECR Ion Source for a High-Brightness Cyclotron

    Science.gov (United States)

    Comeaux, Justin; McIntyre, Peter; Assadi, Saeed

    2011-10-01

    New technology is being developed for high-brightness, high-current cyclotrons with performance benefits for accelerator-driven subcritical fission power, medical isotope production, and proton beam cancer therapy. This paper describes the design for a 65 kV electron cyclotron resonance (ECR) ion source that will provide high-brightness beam for injection into the cyclotron. The ion source is modeled closely upon the one that is used at the Paul Scherrer Institute. Modifications are being made to provide enhanced brightness and compatibility for higher-current operation.

  19. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  20. Recent progress on the superconducting ion source VENUS.

    Science.gov (United States)

    Benitez, J Y; Franzen, K Y; Hodgkinson, A; Loew, T; Lyneis, C M; Phair, L; Saba, J; Strohmeier, M; Tarvainen, O

    2012-02-01

    The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R&D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 eμA of Bi(31+), which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

  1. Ion beam extraction from a matrix ECR plasma source by discrete ion-focusing effect

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, Mihai

    2010-01-01

    Positive or negative ion beams extracted from plasma are used in a large variety of surface functionalization techniques such as implantation, etching, surface activation, passivation or oxidation. Of particular importance is the surface treatment of materials sensitive to direct plasma exposure...... due to high heath fluxes, the controllability of the ion incidence angle, and charge accumulation when treating insulating materials. Despite of a large variety of plasma sources available for ion beam extraction, there is a clear need for new extraction mechanisms that can make available ion beams...... with high current densities that can treat surfaces placed adjacent to the extraction region. This work introduces a new phenomenology for ion beam extraction using the discrete ion-focusing effect associated with three-dimensional plasma-sheath-lenses [1, 2]. Experiments are performed in a matrix...

  2. Small cluster ions from source of negative ions by cesium sputtering

    CERN Document Server

    Wang, X M; Shao, L; Liu, J R; Chu, W K

    2002-01-01

    We investigated the delivery of small cluster ions using a source of negative ions by cesium sputtering (SNICS). The negative cluster ions of B sub n , C sub n , Si sub n , Co sub n , Cu sub n , Ge sub n , Au sub n , GeB sub n and SiB sub n have been extracted by SNICS. Adequate beam current of some small clusters was obtained by changing several parameters for cluster ion yield. After a comprehensive study of the operation parameters, such as target material selection, target geometry, sputtering voltage and current, the small cluster ion current can be increased by several orders of magnitude, with little change on the monomer ion yield.

  3. Ion angular distribution in plasma of vacuum arc ion source with composite cathode and elevated gas pressure.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Yushkov, G Yu; Oks, E M

    2014-02-01

    The Metal Vapor Vacuum Arc (MEVVA) ion sources are capable of generating ion beams of almost all metals of the periodic table. For this kind of ion source, a combination of gas feeding with magnetic field allows the simultaneous generation of both metal and gaseous ions. That makes the MEVVA ion source an excellent instrument for science and application. This work presents results of investigation for ion angular distributions in vacuum arc plasma of Mevva-V.Ru ion source for composite cathodes and for elevated gas pressure. It was shown that for all the cathode materials, singly charged ions have wider angular distribution than multiply charged ions. Increasing the working gas pressure leads to a significant change in the angular distribution of gaseous ions, while with the distribution of metal ions gas remains practically unchanged. The reasons for such different influences are discussed.

  4. Ion beam production and study of radioactive isotopes with the laser ion source at ISOLDE

    Science.gov (United States)

    Fedosseev, Valentin; Chrysalidis, Katerina; Day Goodacre, Thomas; Marsh, Bruce; Rothe, Sebastian; Seiffert, Christoph; Wendt, Klaus

    2017-08-01

    At ISOLDE the majority of radioactive ion beams are produced using the resonance ionization laser ion source (RILIS). This ion source is based on resonant excitation of atomic transitions by wavelength tunable laser radiation. Since its installation at the ISOLDE facility in 1994, the RILIS laser setup has been developed into a versatile remotely operated laser system comprising state-of-the-art solid state and dye lasers capable of generating multiple high quality laser beams at any wavelength in the range of 210-950 nm. A continuous programme of atomic ionization scheme development at CERN and at other laboratories has gradually increased the number of RILIS-ionized elements. At present, isotopes of 40 different elements have been selectively laser-ionized by the ISOLDE RILIS. Studies related to the optimization of the laser-atom interaction environment have yielded new laser ion source types: the laser ion source and trap and the versatile arc discharge and laser ion source. Depending on the specific experimental requirements for beam purity or versatility to switch between different ionization mechanisms, these may offer a favourable alternative to the standard hot metal cavity configuration. In addition to its main purpose of ion beam production, the RILIS is used for laser spectroscopy of radioisotopes. In an ongoing experimental campaign the isotope shifts and hyperfine structure of long isotopic chains have been measured by the extremely sensitive in-source laser spectroscopy method. The studies performed in the lead region were focused on nuclear deformation and shape coexistence effects around the closed proton shell Z = 82. The paper describes the functional principles of the RILIS, the current status of the laser system and demonstrated capabilities for the production of different ion beams including the high-resolution studies of short-lived isotopes and other applications of RILIS lasers for ISOLDE experiments. This article belongs to the Focus on

  5. RF H-minus ion source development in China spallation neutron source

    Science.gov (United States)

    Chen, W.; Ouyang, H.; Xiao, Y.; Liu, S.; Lü, Y.; Cao, X.; Huang, T.; Xue, K.

    2017-08-01

    China Spallation Neutron Source (CSNS) phase-I project currently uses a Penning surface plasma H- ion source, which has a life time of several weeks with occasional sparks between high voltage electrodes. To extend the life time of the ion source and prepare for the CSNS phase-II, we are trying to develop a RF negative hydrogen ion source with external antenna. The configuration of the source is similar to the DESY external antenna ion source and SNS ion source. However several changes are made to improve the stability and the life time. Firstly, Si3N4 ceramic with high thermal shock resistance, and high thermal conductivity is used for plasma chamber, which can endure an average power of 2000W. Secondly, the water-cooled antenna is brazed on the chamber to improve the energy efficiency. Thirdly, cesium is injected directly to the plasma chamber if necessary, to simplify the design of the converter and the extraction. Area of stainless steel exposed to plasma is minimized to reduce the sputtering and degassing. Instead Mo, Ta, and Pt coated materials are used to face the plasma, which makes the self-cleaning of the source possible.

  6. A simple radionuclide-driven single-ion source

    CERN Document Server

    Díez, M Montero; Fairbank, W; Gratta, G; Barbeau, P S; Barry, K; DeVoe, R; Dolinski, M J; Green, M; LePort, F; Müller, A R; Neilson, R; O'Sullivan, K; Ackerman, N; Aharmin, B; Auger, M; Benitez-Medina, C; Breidenbach, M; Burenkov, A; Cook, S; Daniels, T; Donato, K; Farine, J; Giroux, G; Gornea, R; Graham, K; Hagemann, C; Hall, C; Hall, K; Hallman, D; Hargrove, C; Herrin, S; Karelin, A; Kaufman, L J; Kuchenkov, A; Kumar, K; Lacey, J; Leonard, D S; Mackay, D; MacLellan, R; Mong, B; Niner, E; Odian, A; Piepke, A; Pocar, A; Prescott, C Y; Pushkin, K; Rollin, E; Rowson, P C; Sinclair, D; Slutsky, S; Stekhanov, V; Vuilleumier, J -L; Wichoski, U; Wodin, J; Yang, L; Yen, Y -R

    2010-01-01

    We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating 148Gd onto a silicon {\\alpha}-particle detector and vapor depositing a layer of BaF2 over it. 144Sm recoils from the alpha decay of 148Gd are used to dislodge Ba+ ions from the BaF2 layer and emit them in the surrounding environment. The simultaneous detection of an {\\alpha} particle in the substrate detector allows for tagging of the nuclear decay and of the Ba+ emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

  7. A simple radionuclide-driven single-ion source

    Energy Technology Data Exchange (ETDEWEB)

    Montero Diez, M.; Twelker, K.; Gratta, G.; Barbeau, P. S.; Barry, K.; DeVoe, R.; Dolinski, M. J.; Green, M.; LePort, F.; Mueller, A. R.; Neilson, R.; O' Sullivan, K. [Department of Physics, Stanford University, Stanford, California 94305 (United States); Fairbank, W. Jr.; Benitez-Medina, C.; Cook, S.; Hall, K.; Mong, B. [Department of Physics, Colorado State University, Fort Collins, Colorado 80523 (United States); Ackerman, N.; Breidenbach, M.; Herrin, S. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); and others

    2010-11-15

    We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating {sup 148}Gd onto a silicon {alpha}-particle detector and vapor depositing a layer of BaF{sub 2} over it. {sup 144}Sm recoils from the alpha decay of {sup 148}Gd are used to dislodge Ba{sup +} ions from the BaF{sub 2} layer and emit them in the surrounding environment. The simultaneous detection of an {alpha} particle in the substrate detector allows for tagging of the nuclear decay and of the Ba{sup +} emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

  8. Laserspray ionization imaging of multiply charged ions using a commercial vacuum MALDI ion source.

    Science.gov (United States)

    Inutan, Ellen D; Wager-Miller, James; Mackie, Ken; Trimpin, Sarah

    2012-11-06

    This is the first report of imaging mass spectrometry (MS) from multiply charged ions at vacuum. Laserspray ionization (LSI) was recently extended to applications at vacuum producing electrospray ionization-like multiply charged ions directly from surfaces using a commercial intermediate pressure matrix-assisted laser desorption/ionization ion mobility spectrometry (IMS) MS instrument. Here, we developed a strategy to image multiply charged peptide ions. This is achieved by the use of 2-nitrophloroglucinol as matrix for spray deposition onto the tissue section and implementation of "soft" acquisition conditions including lower laser power and ion accelerating voltages similar to electrospray ionization-like conditions. Sufficient ion abundance is generated by the vacuum LSI method to employ IMS separation in imaging multiply charged ions obtained on a commercial mass spectrometer ion source without physical instrument modifications using the laser in the commercially available reflection geometry alignment. IMS gas-phase separation reduces the complexity of the ion signal from the tissue, especially for multiply charged relative to abundant singly charged ions from tissue lipids. We show examples of LSI tissue imaging from charge state +2 of three endogenous peptides consisting of between 1 and 16 amino acid residues from the acetylated N-terminal end of myelin basic protein: mass-to-charge (m/z) 795.81 (+2) molecular weight (MW) 1589.6, m/z 831.35 (+2) MW 1660.7, and m/z 917.40 (+2) MW 1832.8.

  9. Analysis of the H- ion emissive surface in the extraction region of negative ion sources.

    Science.gov (United States)

    Kameyama, N; Fukuyama, T; Wada, S; Kuppel, S; Tsumori, K; Nakano, H; Hatayama, A; Miyamoto, K; Fukano, A; Bacal, M

    2012-02-01

    To understand the plasma characteristics in the extraction region of negative H(-) sources is very important for the optimization of H(-) extraction from the sources. The profile of plasma density and electrostatic potential in the extraction region with and without extraction grid voltage are analyzed with a 2D particle in cell modeling of the NIFS-RD H(-) sources. The simulation results make clear the physical process forming a double ion plasma layer (which consists only of positive H(+) and negative H(-) ions) recently observed in the Cs-seeded experiments of the NIFS-R&D source in the vicinity of the extraction hole and the plasma grid. The results also give a useful insight into the formation mechanism of the plasma meniscus and the H(-) extraction process for such double ion plasma.

  10. Development of a laser ion source for production of high-intensity heavy-ion beams

    Science.gov (United States)

    Kashiwagi, H.; Yamada, K.; Kurashima, S.

    2017-09-01

    A laser ion source has been developed as a high-intensity source for the ion implanter and the single pulsed beam of the azimuthally varying field cyclotron at TIARA. Highly charged beams of C5+ and C6+ ions and low-charged beams of heavy ions such as C, Al, Ti, Cu, Au, and Pt are required for the single-pulse acceleration in the cyclotron and for the ion implanter, respectively. In the vacuum chamber of the ion source, a target holder on a three-dimensional linear-motion stage provides a fresh surface for each laser shot. A large-sized target with a maximum size of 300 mm × 135 mm is mounted on the holder for long-term operation. The ion current (ion charge flux) in the laser-produced plasma is measured by a Faraday cup and time-of-flight spectra of each charge state are measured using a 90° cylindrical electrostatic analyzer just behind the Faraday cup. Carbon-plasma-generation experiments indicate that the source produces intense high- and low-charged pulsed ion beams. At a laser energy of 483 mJ (2.3 × 1013 W/cm2), average C6+ current of 13 mA and average C5+ current of 23 mA were obtained over the required time duration for single-pulse acceleration in the cyclotron (49 ns for C6+ and 80 ns for C5+). Furthermore, at 45 mJ (2.1 × 1012 W/cm2), an average C2+ current of 1.6 mA over 0.88 μs is obtained.

  11. Numerical Simulation and Interpretation of the Results of Lead Ion Production in the ECR Ion Source at CERN

    CERN Document Server

    Haseroth, H; Langbein, K; Shirkov, G D

    1995-01-01

    A new library of the computer codes for the mathematical simulation of heavy ion production in the ECR ion source is presented. These codes are based on the equations of model of ion confinement and losses in ECR ion sources. The ECR4 developed at GANIL is now used for lead ion production for the accelerator complex at CERN. An ion pulse with a current of up to 100 emA of Pb27+ has been regularly injected into the linac since May 1994. The results of numerical simulation with these computer codes and interpretation of experimental data of lead ion production in the ECR source at CERN are presented.

  12. Ferroelectric Plasma Source for Heavy Ion Beam Charge Neutralization

    CERN Document Server

    Efthimion, Philip; Gilson, Erik P; Grisham, Larry; Logan, B G; Waldron, William; Yu, Simon

    2005-01-01

    Plasmas are employed as a medium for charge neutralizing heavy ion beams to allow them to focus to a small spot size. Calculations suggest that plasma at a density of 1-100 times the ion beam density and at a length ~ 0.1-1 m would be suitable. To produce 1 meter plasma, large-volume plasma sources based upon ferroelectric ceramics are being considered. These sources have the advantage of being able to increase the length of the plasma and operate at low neutral pressures. The source will utilize the ferroelectric ceramic BaTiO3 to form metal plasma. The drift tube inner surface of the Neutralized Drift Compression Experiment (NDCX) will be covered with ceramic. High voltage (~ 1-5 kV) is applied between the drift tube and the front surface of the ceramic by placing a wire grid on the front surface. A prototype ferroelectric source 20 cm long produced plasma densities ~ 5x1011 cm-3. The source was integrated into the experiment and successfully charge neutralized the K ion beam. Presently, the 1 meter source ...

  13. Production of multiply charge-state ions in a multicusp ion source

    Science.gov (United States)

    Williams, M. D.; deVries, G. J.; Gough, R. A.; Leung, K. N.; Monroy, M.

    1996-03-01

    High charge state ion beams are commonly used in atomic and nuclear physics experiments. Multiply charged ions are normally produced in an ECR or in an EBIS. Multicusp generators can confine primary electrons very efficiently. Therefore, the electrical and gas efficiencies of these devices are high. Since the magnetic cusp fields are localized near the chamber wall, large volumes of uniform and high density plasmas can be obtained at low pressure, conditions favorable for the formation of multiply charged state ions. Attempts have been made at LBNL to generate multiply charged ion beams by employing a 25-cm diam by 25-cm long multicusp source. Experimental results demonstrated that charge states as high as 7+ can be obtained with argon or xenon plasmas. Multiply charged metallic ions such as tungsten and titanium have also been successfully formed in the multicusp source by evaporation and sputtering processes. In order to extend the charge state to higher values, a novel technique of injecting high energy electrons into the source plasma is proposed. If this is successful, the multicusp source will become very useful for radioactive beam accelerators, ion implantation, and nuclear physics applications.

  14. Production of multiply charge-state ions in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Williams, M.D.; deVries, G.J.; Gough, R.A.; Leung, K.N.; Monroy, M. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    1996-03-01

    High charge state ion beams are commonly used in atomic and nuclear physics experiments. Multiply charged ions are normally produced in an ECR or in an EBIS. Multicusp generators can confine primary electrons very efficiently. Therefore, the electrical and gas efficiencies of these devices are high. Since the magnetic cusp fields are localized near the chamber wall, large volumes of uniform and high density plasmas can be obtained at low pressure, conditions favorable for the formation of multiply charged state ions. Attempts have been made at LBNL to generate multiply charged ion beams by employing a 25-cm diam by 25-cm long multicusp source. Experimental results demonstrated that charge states as high as 7+ can be obtained with argon or xenon plasmas. Multiply charged metallic ions such as tungsten and titanium have also been successfully formed in the multicusp source by evaporation and sputtering processes. In order to extend the charge state to higher values, a novel technique of injecting high energy electrons into the source plasma is proposed. If this is successful, the multicusp source will become very useful for radioactive beam accelerators, ion implantation, and nuclear physics applications. {copyright} {ital 1996 American Institute of Physics.}

  15. Enhanced Physicochemical and Biological Properties of Ion-Implanted Titanium Using Electron Cyclotron Resonance Ion Sources

    Directory of Open Access Journals (Sweden)

    Csaba Hegedűs

    2016-01-01

    Full Text Available The surface properties of metallic implants play an important role in their clinical success. Improving upon the inherent shortcomings of Ti implants, such as poor bioactivity, is imperative for achieving clinical use. In this study, we have developed a Ti implant modified with Ca or dual Ca + Si ions on the surface using an electron cyclotron resonance ion source (ECRIS. The physicochemical and biological properties of ion-implanted Ti surfaces were analyzed using various analytical techniques, such as surface analyses, potentiodynamic polarization and cell culture. Experimental results indicated that a rough morphology was observed on the Ti substrate surface modified by ECRIS plasma ions. The in vitro electrochemical measurement results also indicated that the Ca + Si ion-implanted surface had a more beneficial and desired behavior than the pristine Ti substrate. Compared to the pristine Ti substrate, all ion-implanted samples had a lower hemolysis ratio. MG63 cells cultured on the high Ca and dual Ca + Si ion-implanted surfaces revealed significantly greater cell viability in comparison to the pristine Ti substrate. In conclusion, surface modification by electron cyclotron resonance Ca and Si ion sources could be an effective method for Ti implants.

  16. A Multi-Sample Cs-Sputter Negative Ion Source

    Energy Technology Data Exchange (ETDEWEB)

    Alton, G.D.; Ball, J.A.; Bao, Y.; Cui, B.; Reed, C.A.; Williams, C.

    1998-10-05

    A multi-sample Cs sputter negative-ion source, equipped with a conical-geometry, W-surface-ionizer has been designed and fabricated that permits sample changes without disruption of on-line accelerator operation. Sample changing is effected by actuating an electro-pneumatic control system located at ground potential that drives an air-motor-driven sample-indexing-system mounted at high voltage; this arrangement avoids complications associated with indexing mechanisms that rely on electronic power-supplies located at high potential. In-beam targets are identified by LED indicator lights derived from a fiber-optic, Gray-code target-position sensor. Aspects of the overall source design and details of the indexing mechanism along with operational parameters, ion optics. intensities, and typical emittances for a variety of negative-ion species will be presented in this report.

  17. Design of a versatile multiaperture negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Cavenago, M. [INFN-LNL, viale dell' Universita n. 2, 35020 Legnaro (Italy); Kulevoy, T.; Petrenko, S. [INFN-LNL, viale dell' Universita n. 2, 35020 Legnaro (Italy); ITEP, Bolshaja Cheremushkinskaja 25, 110079, Moscow (Russian Federation); Antoni, V.; Bigi, M.; Gazza, E.; Recchia, M.; Serianni, G.; Veltri, P. [Consorzio RFX, Associazione EURATOM-ENEA Sulla Fusione, c.so Stati Uniti 4, 35127, Padova (Italy)

    2010-02-15

    Negative ion sources are a key component of the neutral beam injector to be installed in the International Thermonuclear Experimental Reactor. At present research and development activities address several important issues related to beam extraction, optics, and optimization. Together with the design of real size devices and the accumulation of atomic cross section databases, a relatively small negative ion source [130 mA of H{sup -} at 60 kV, named Negative Ion Optimization phase 1 (NIO1)] is under construction at Consorzio RFX to contribute to benchmark numerical simulation tools and to test components, such as emittance scanners, beam dumps, and cesium ovens. NIO1 design, magnet configuration, and rf coupling simulations are described.

  18. Fundamental studies on the Cs dynamics under ion source conditions

    Energy Technology Data Exchange (ETDEWEB)

    Friedl, R., E-mail: roland.friedl@physik.uni-augsburg.de; Fantz, U. [AG Experimentelle Plasmaphysik (EPP), Institute of Physics, University of Augsburg, 86135 Augsburg (Germany); Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstraße 2, 85748 Garching (Germany)

    2014-02-15

    The performance of surface conversion based negative hydrogen ion sources is mainly determined by the caesium dynamics. Therefore, fundamental investigations in vacuum and plasma are performed at a flexible laboratory setup with ion source parameters. Studies on the influence of Cs on the plasma parameters of H{sub 2} and D{sub 2} plasmas showed that n{sub e} and T{sub e} in the bulk plasma are not affected by relevant amounts of Cs and no isotopic differences could be observed. The coating of the vessel surfaces with Cs, however, leads to a considerable gettering of hydrogen atoms from the plasma volume and to the decrease of n{sub e} close to a sample surface due to the formation of negative ions.

  19. Note: A pulsed laser ion source for linear induction accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H., E-mail: bamboobbu@hotmail.com [Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-106, Mianyang 621900 (China); School of Physics, Peking University, Beijing 100871 (China); Zhang, K.; Shen, Y.; Jiang, X.; Dong, P.; Liu, Y.; Wang, Y.; Chen, D.; Pan, H.; Wang, W.; Jiang, W.; Long, J.; Xia, L.; Shi, J.; Zhang, L.; Deng, J. [Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-106, Mianyang 621900 (China)

    2015-01-15

    We have developed a high-current laser ion source for induction accelerators. A copper target was irradiated by a frequency-quadrupled Nd:YAG laser (266 nm) with relatively low intensities of 10{sup 8} W/cm{sup 2}. The laser-produced plasma supplied a large number of Cu{sup +} ions (∼10{sup 12} ions/pulse) during several microseconds. Emission spectra of the plasma were observed and the calculated electron temperature was about 1 eV. An induction voltage adder extracted high-current ion beams over 0.5 A/cm{sup 2} from a plasma-prefilled gap. The normalized beam emittance measured by a pepper-pot method was smaller than 1 π mm mrad.

  20. A narrow-band, variable energy ion source derived from a wire plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Gueroult, R; Elias, P Q; Packan, D [ONERA Palaiseau, 91761 Palaiseau (France); Rax, J M, E-mail: renaud.gueroult@polytechnique.edu [LPP, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2011-08-15

    A low pressure wire-induced plasma source (WIPS) operated in its high-pressure mode ({approx}10{sup -2} mbar) exhibits a narrow ion energy distribution function peaked at an energy corresponding to the discharge voltage. In order to take advantage of this peculiar feature, we design an electrode geometry enabling the acceleration of ions extracted from a WIPS. Probing of the obtained ion plume by means of a retarding potential analyser (RPA) demonstrates the capability of such an ion source to generate narrow-band (full width at half maximum of about 20 eV), variable energy (1 to 5 keV) ion beams. Comparison with particle-in-cell simulations of the WIPS shows that the energy spread of these ion beams is actually about 10 eV, the slight broadening being mainly the effect of the limited planar RPA energy resolution. The ion beam spot size measured at 6 cm of the ion source exit is about 3 mm for a 10 {mu}A He{sup +} beam at 2 keV, with a divergence of about one degree. Operating the WIPS in argon and xenon leads to similar properties for Ar{sup +} and Xe{sup +} beams, and in principle other species could also be used.

  1. Handling radiation generated during an ion source commissioning

    Science.gov (United States)

    Ren, H. T.; Zhao, J.; Peng, S. X.; Lu, P. N.; Zhou, Q. F.; Xu, Y.; Chen, J.; Zhang, T.; Zhang, A. L.; Guo, Z. Y.; Chen, J. E.

    2014-02-01

    Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H+ ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D+ beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.

  2. The Cathode Ramper: Application for the Duoplasmatron Ion Source

    CERN Document Server

    Sánchez-Conejo, J

    2003-01-01

    The purpose of the Cathode Ramper Application is to heat the Linac 2 duoplasmatron ion source cathode up to a desired temperature selected by the user. The application has been developed in Java, making use of the Java Development Kit 1.4 and the PS Java environment.

  3. A LASER ION-SOURCE FOR ONLINE MASS SEPARATION

    NARCIS (Netherlands)

    VANDUPPEN, P; DENDOOVEN, P; HUYSE, M; VERMEEREN, L; QAMHIEH, ZN; SILVERANS, RE; VANDEWEERT, E

    1992-01-01

    A laser ion source based on resonance photo ionization in a gas cell is proposed. The gas cell, filled with helium, consists of a target chamber in which the recoil products are stopped and neutralized, and an ionization chamber where the atoms of interest are selectively ionized by the laser light.

  4. Estimation of Sputtering Damages on a Magnetron H- Ion Source Induced by Cs+ and H+ Ions

    CERN Document Server

    Pereira, H; Alessi, J; Kalvas, t

    2013-01-01

    An H− ion source is being developed for CERN’s Linac4 accelerator. A beam current requirement of 80 mA and a reliability above 99% during 1 year with 3 month uninterrupted operation periods are mandatory. To design a low-maintenance long life-time source, it is important to investigate and understand the wear mechanisms. A cesiated plasma discharge ion source, such as the BNL magnetron source, is a good candidate for the Linac4 ion source. However, in the magnetron source operated at BNL, the removal of material from the molybdenum cathode and the stainless steel anode cover plate surfaces is visible after extended operation periods. The observed sputtering traces are shown to result from cesium vapors and hydrogen gas ionized in the extraction region and subsequently accelerated by the extraction field. This paper presents a quantitative estimate of the ionization of cesium and hydrogen by the electron and H− beams in the extraction region of BNL’s magnetron ion source. The respective contributions o...

  5. Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chang Seouk [Busan Center, Korea Basic Science Institute, Busan 609-735 (Korea, Republic of); School of Mechanical Engineering, Pusan National University, Pusan 609-735 (Korea, Republic of); Lee, Byoung-Seob; Choi, Seyong; Yoon, Jang-Hee; Kim, Hyun Gyu; Ok, Jung-Woo; Park, Jin Yong; Kim, Seong Jun; Bahng, Jungbae; Hong, Jonggi; Won, Mi-Sook, E-mail: mswon@kbsi.re.kr [Busan Center, Korea Basic Science Institute, Busan 609-735 (Korea, Republic of); Lee, Seung Wook, E-mail: Seunglee@pusan.ac.kr [School of Mechanical Engineering, Pusan National University, Pusan 609-735 (Korea, Republic of)

    2016-02-15

    The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

  6. Review of laser-driven ion sources and their applications.

    Science.gov (United States)

    Daido, Hiroyuki; Nishiuchi, Mamiko; Pirozhkov, Alexander S

    2012-05-01

    For many years, laser-driven ion acceleration, mainly proton acceleration, has been proposed and a number of proof-of-principle experiments have been carried out with lasers whose pulse duration was in the nanosecond range. In the 1990s, ion acceleration in a relativistic plasma was demonstrated with ultra-short pulse lasers based on the chirped pulse amplification technique which can provide not only picosecond or femtosecond laser pulse duration, but simultaneously ultra-high peak power of terawatt to petawatt levels. Starting from the year 2000, several groups demonstrated low transverse emittance, tens of MeV proton beams with a conversion efficiency of up to several percent. The laser-accelerated particle beams have a duration of the order of a few picoseconds at the source, an ultra-high peak current and a broad energy spectrum, which make them suitable for many, including several unique, applications. This paper reviews, firstly, the historical background including the early laser-matter interaction studies on energetic ion acceleration relevant to inertial confinement fusion. Secondly, we describe several implemented and proposed mechanisms of proton and/or ion acceleration driven by ultra-short high-intensity lasers. We pay special attention to relatively simple models of several acceleration regimes. The models connect the laser, plasma and proton/ion beam parameters, predicting important features, such as energy spectral shape, optimum conditions and scalings under these conditions for maximum ion energy, conversion efficiency, etc. The models also suggest possible ways to manipulate the proton/ion beams by tailoring the target and irradiation conditions. Thirdly, we review experimental results on proton/ion acceleration, starting with the description of driving lasers. We list experimental results and show general trends of parameter dependences and compare them with the theoretical predictions and simulations. The fourth topic includes a review of

  7. Fish bones--a highly available calcium source for growing pigs.

    Science.gov (United States)

    Malde, M K; Graff, I E; Siljander-Rasi, H; Venäläinen, E; Julshamn, K; Pedersen, J I; Valaja, J

    2010-10-01

    In general, there is a lack of scientific documentation of nutritional value of marine by-products. The bone fraction from fish has been regarded as waste. Due to the high mineral content of fish bones, this material can be well suitable as a natural calcium source. In the present study, apparent calcium absorption of different fish bone sources was tested using growing pigs. The experimental diets consisted of boiled salmon frames, or salmon, saithe or cod bones treated with enzymes. Calcium carbonate (CaCO(3)) was used as control. The experimental diets were formulated to contain 0.7% total calcium of which the added calcium source to be tested contributed about 71% (study 1) and 86% (study 2). Except for the calcium and phosphorus sources, the animals received similar basal diets. Apparent calcium digestibility coefficient was calculated using yttrium as indicator (both studies) and was based on complete collection of faeces and urine (study 2). The experimental design was parallel and cross-over in study 1 and study 2, respectively. In study 1, piglets getting salmon bone treated with enzymes had significantly higher calcium absorption than piglets getting boiled fish bone or calcium carbonate. Therefore, in the second study only enzymatically treated fish bones were included. The higher calcium absorption from enzymatically treated salmon bone was also found in study 2, but this time not significant. Calcium from boiled salmon bones in study I, and from enzymatically treated saithe and cod bones in study II were absorbed as well as the calcium carbonate control. The results indicate that fish bones may be a useful and well absorbed calcium source. Due to the high mineral content of the bone fraction, salmon bones can be well suitable as a natural calcium and phosphorus source in, for example, food, feed or as supplement.

  8. Laser ion source for multi-nucleon transfer reaction products

    Science.gov (United States)

    Hirayama, Y.; Watanabe, Y. X.; Imai, N.; Ishiyama, H.; Jeong, S. C.; Miyatake, H.; Oyaizu, M.; Kimura, S.; Mukai, M.; Kim, Y. H.; Sonoda, T.; Wada, M.; Huyse, M.; Kudryavtsev, Yu.; Van Duppen, P.

    2015-06-01

    We have developed a laser ion source for the target-like fragments (TLFs) produced in multi-nucleon transfer (MNT) reactions. The operation principle of the source is based on the in-gas laser ionization and spectroscopy (IGLIS) approach. In the source TLFs are thermalized and neutralized in high pressure and high purity argon gas, and are extracted after being selectively re-ionized in a multi-step laser resonance ionization process. The laser ion source has been implemented at the KEK Isotope Separation System (KISS) for β-decay spectroscopy of neutron-rich isotopes with N = 126 of nuclear astrophysical interest. The simulations of gas flow and ion-beam optics have been performed to optimize the gas cell for efficient thermalization and fast transporting the TLFs, and the mass-separator for efficient transport with high mass-resolving power, respectively. To confirm the performances expected at the design stage, off-line experiments have been performed by using 56Fe atoms evaporated from a filament in the gas cell. The gas-transport time of 230 ms in the argon cell and the measured KISS mass-resolving power of 900 are consistent with the designed values. The high purity of the gas-cell system, which is extremely important for efficient and highly-selective production of laser ions, was achieved and confirmed from the mass distribution of the extracted ions. After the off-line tests, on-line experiments were conducted by directly injecting energetic 56Fe beam into the gas cell. After thermalization of the injected 56Fe beam, laser-produced singly-charged 56Fe+ ions were extracted. The extraction efficiency and selectivity of the gas cell in the presence of plasma induced by 56Fe beam injection as well as the time profile of the extracted ions were investigated; extraction efficiency of 0.25%, a beam purity of >99% and an extraction time of 270 ms. It has been confirmed that the performance of the KISS laser ion source is satisfactory to start the measurements of

  9. Efficient cesiation in RF driven surface plasma negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Belchenko, Yu.; Ivanov, A.; Konstantinov, S.; Sanin, A., E-mail: sanin@inp.nsk.su; Sotnikov, O. [Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2016-02-15

    Experiments on hydrogen negative ions production in the large radio-frequency negative ion source with cesium seed are described. The system of directed cesium deposition to the plasma grid periphery was used. The small cesium seed (∼0.5 G) provides an enhanced H{sup −} production during a 2 month long experimental cycle. The gradual increase of negative ion yield during the long-term source runs was observed after cesium addition to the source. The degraded H{sup −} production was recorded after air filling to the source or after the cesium washing away from the driver and plasma chamber walls. The following source conditioning by beam shots produces the gradual recovery of H{sup −} yield to the high value. The effect of H{sup −} yield recovery after cesium coverage passivation by air fill was studied. The concept of cesium coverage replenishment and of H{sup −} yield recovery due to sputtering of cesium from the deteriorated layers is discussed.

  10. Review of highly charged heavy ion production with electron cyclotron resonance ion source (invited)

    Science.gov (United States)

    Nakagawa, T.

    2014-02-01

    The electron cyclotron resonance ion source (ECRIS) plays an important role in the advancement of heavy ion accelerators and other ion beam applications worldwide, thanks to its remarkable ability to produce a great variety of intense highly charged heavy ion beams. Great efforts over the past decade have led to significant ECRIS performance improvements in both the beam intensity and quality. A number of high-performance ECRISs have been built and are in daily operation or are under construction to meet the continuously increasing demand. In addition, comprehension of the detailed and complex physical processes in high-charge-state ECR plasmas has been enhanced experimentally and theoretically. This review covers and discusses the key components, leading-edge developments, and enhanced ECRIS performance in the production of highly charged heavy ion beams.

  11. Power supply system for negative ion source at IPR

    Energy Technology Data Exchange (ETDEWEB)

    Gahlaut, Agrajit; Sonara, Jashwant; Parmar, K G; Soni, Jignesh; Bandyopadhyay, M; Singh, Mahendrajit; Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun, E-mail: agrajit@ipr.res.i [Institute for Plasma Research, Gandhinagar, Gujarat - 382428 (India)

    2010-02-01

    The first step in the Indian program on negative ion beams is the setting up of Negative ion Experimental Assembly - RF based, where 100 kW of RF power shall be coupled to a plasma source producing plasma of density {approx}5 x 10{sup 12} cm{sup -3}, from which {approx} 10 A of negative ion beam shall be produced and accelerated to 35 kV, through an electrostatic ion accelerator. The experimental system is modelled similar to the RF based negative ion source, BATMAN presently operating at IPP, Garching, Germany. The mechanical system for Negative Ion Source Assembly is close to the IPP source, remaining systems are designed and procured principally from indigenous sources, keeping the IPP configuration as a base line. High voltage (HV) and low voltage (LV) power supplies are two key constituents of the experimental setup. The HV power supplies for extraction and acceleration are rated for high voltage ({approx}15 to 35kV), and high current ({approx} 15 to 35A). Other attributes are, fast rate of voltage rise (< 5ms), good regulation (< {+-}1%), low ripple (< {+-}2%), isolation ({approx}50kV), low energy content (< 10J) and fast cut-off (< 100{mu}s). The low voltage (LV) supplies required for biasing and providing heating power to the Cesium oven and the plasma grids; have attributes of low ripple, high stability, fast and precise regulation, programmability and remote operation. These power supplies are also equipped with over-voltage, over-current and current limit (CC Mode) protections. Fault diagnostics, to distinguish abnormal rise in currents (breakdown faults) with over-currents is enabled using fast response breakdown and over-current protection scheme. To restrict the fault energy deposited on the ion source, specially designed snubbers are implemented in each (extraction and acceleration) high voltage path to swap the surge energy. Moreover, the monitoring status and control signals from these power supplies are required to be electrically ({approx} 50k

  12. Design of 1+ Ion Source Coupling First Design of the Resonant Ionization Laser Ion Source For the Multi-Mega Watt Target Station

    CERN Document Server

    A. Olivier, F. Le Blanc, C. Lau

    The realisation of next-generation ion sources suitable for the EURISOL multi-mega-watt (MMW) target station needs exhaustive studies and developments. An exhaustive review was carried out to evaluate the capability of the ion-sources to operate under the irradiation conditions of the MMW target station. In addition, selectivity must be taken into account to avoid the spread of unwanted radioactivity out of the target-ion-source system (TIS).These studies led to consider RILIS (Resonance Ionization Laser Ion Source) as the reference ion source for this target station.

  13. Simulation of H{sup -} ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T.; Tarvainen, O. [Department of Physics, University of Jyvaeskylae, Jyvaeskylae (Finland); Welton, R. F.; Han, B. X.; Stockli, M. P. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2012-02-15

    A three-dimensional ion optical code IBSimu, which is being developed at University of Jyvaeskylae, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H{sup -} ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H{sup -} currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two solenoids has been designed to transport the beam from the alternative electrostatic extraction systems to the radio frequency quadrupole.

  14. First experiments with gasdynamic ion source in CW mode

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V., E-mail: skalyga@ipfran.ru; Vodopyanov, A. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., Nizhny Novgorod 603950 (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., Nizhny Novgorod 603950 (Russian Federation); Izotov, I.; Golubev, S. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., Nizhny Novgorod 603950 (Russian Federation); Tarvainen, O. [Department of Physics, University of Jyvaskyla, P.O. Box 35 (YFL), 40500 Jyvaskyla (Finland)

    2016-02-15

    A new type of ECR ion source—a gasdynamic ECR ion source—has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600–700 emA/cm{sup 2} in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for plasma heating in a magnetic trap with simple mirror configuration. Initial studies of plasma parameters were performed. Ion beams with pulsed and CW high voltage were successfully extracted from the CW discharge. Obtained experimental results demonstrate that all advantages of the gasdynamic source can be realized also in CW operation.

  15. Ion Current Density Calculation of the Inductive Radio Frequency Ion Source

    Directory of Open Access Journals (Sweden)

    V.I. Voznyi

    2012-10-01

    Full Text Available A radio-frequency (RF inductive ion source at 27.12 MHz is investigated. With a global model of the argon discharge, plasma density, electron temperature and ion current density of the ion source is calculated in relation to absorbed RF power and gas pressure as a discharge chamber size changes. It is found that ion beam current density grows as the discharge chamber size decreases. Calculations show that in the RF source with a discharge chamber 30 mm in diameter and 35 mm long the ion current density is 40 mA/cm2 at 100 W of absorbed RF power and 7 mTorr of pressure, and agrees well with experimentally measured value of 43 mA/cm2. With decreasing discharge chamber diameter to 15 mm ion current density can reach 85 mA/cm2 at absorbed RF power of 100 W.

  16. The Resonance Ionization Laser Ion Source RILIS - leading all-rounder of on-line ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Rothe, Sebastian [CERN, Geneva (Switzerland); Institut fuer Physik, Univ. Mainz (Germany); Fedosseev, Valentin; Fink, Daniel; Seliverstov, Maxim [CERN, Geneva (Switzerland); Rossel, Ralf [CERN, Geneva (Switzerland); Institut fuer Physik, Univ. Mainz (Germany); Hochschule RheinMain, Wiesbaden (Germany); Wendt, Klaus [Institut fuer Physik, Univ. Mainz (Germany)

    2012-07-01

    The resonance ionization laser ion source (RILIS) of the on-line isotope separator facility ISOLDE at CERN, is based on the method of stepwise resonant laser excitation and ionization of atoms. The element selectivity of the RILIS complements the mass selection process of the ISOLDE separator magnets to provide high purity ion beams of many isotopes. The RILIS, which now includes two complementary and independent tunable laser systems (dye and titanium:sapphire lasers), has been significantly improved since its first demonstration of selective ionization of Yb isotopes in 1992. Today, on account of the high degree of selectivity for the 27 elements now offered, the annual operation of RILIS exceeds 2500 h, making it the most versatile and commonly used ion source at ISOLDE. The use of a narrow band dye laser enables precision in-source laser spectroscopy of isotope shifts and hyperfine structures of isotopes far from stability as well as the production of isomer pure beams as has been demonstrated for Ag, Cu, Pb, Bi, Po, and Tl. A recent upgrade of the RILIS comprises the incorporation of a complementary all solid state laser system as well as the Laser Ion Source Trap (LIST), which greatly enhances selectivity by suppressing any surface ionized isobars.

  17. A Study on the Ion Beam Extraction using Duo-PiGatron Ion source for Vertical Type Ion Beam Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sok; Lee, Chan young; Lee, Jae Sang [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    In Korea Multipurpose Accelerator Complex (KOMAC), we have started ion beam service in the new beam utilization building since March this year. For various ion beam irradiation services, we are developed implanters such as metal (150keV/1mA), gaseous (200keV/5mA) and high current ion beam facility (20keV/150mA). One of the new one is a vertical type ion beam facility without acceleration tube (60keV/20mA) which is easy to install the sample. After the installation is complete, it is where you are studying the optimal ion beam extraction process. Detailed experimental results will be presented. Vertical Type Ion Beam Facility without acceleration tube of 60keV 20mA class was installed. We successfully extracted 60keV 20mA using Duo- PiGatron Ion source for Vertical Type Ion Beam Facility. Use the BPM and Faraday-cup, is being studied the optimum conditions of ion beam extraction.

  18. Numerical modeling of the SNS H- ion source

    Science.gov (United States)

    Veitzer, Seth A.; Beckwith, Kristian R. C.; Kundrapu, Madhusudhan; Stoltz, Peter H.

    2015-04-01

    Ion source rf antennas that produce H- ions can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator is one of the top priorities of the SNS H- Source Program at ORNL. Numerical modeling of ion sources can provide techniques for optimizing design in order to reduce antenna failures. There are a number of difficulties in developing accurate models of rf inductive plasmas. First, a large range of spatial and temporal scales must be resolved in order to accurately capture the physics of plasma motion, including the Debye length, rf frequencies on the order of tens of MHz, simulation time scales of many hundreds of rf periods, large device sizes on tens of cm, and ion motions that are thousands of times slower than electrons. This results in large simulation domains with many computational cells for solving plasma and electromagnetic equations, short time steps, and long-duration simulations. In order to reduce the computational requirements, one can develop implicit models for both fields and particle motions (e.g. divergence-preserving ADI methods), various electrostatic models, or magnetohydrodynamic models. We have performed simulations using all three of these methods and have found that fluid models have the greatest potential for giving accurate solutions while still being fast enough to perform long timescale simulations in a reasonable amount of time. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS H- ion source. We found that a reduced, single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field generated increased bulk plasma velocities of > 200 m/s in the region of the antenna where ablation is often observed in the SNS source. We report

  19. Gas feeding molecular phosphorous ion source for semiconductor implanters

    Science.gov (United States)

    Gushenets, V. I.; Oks, E. M.; Bugaev, A. S.; Kulevoy, T. V.; Hershcovitch, A.

    2014-02-01

    Phosphorus is a much used dopant in semiconductor technology. Its vapors represent a rather stable tetratomic molecular compound and are produced from one of the most thermodynamically stable allotropic forms of phosphorus—red phosphorus. At vacuum heating temperatures ranging from 325 °C, red phosphorus evaporates solely as P4 molecules (P4/P2 ˜ 2 × 105, P4/P ˜ 1021). It is for this reason that red phosphorus is best suited as a source of polyatomic molecular ion beams. The paper reports on experimental research in the generation of polyatomic phosphorus ion beams with an alternative P vapor source for which a gaseous compound of phosphorus with hydrogen - phosphine - is used. The ion source is equipped with a specially designed dissociator in which phosphine heated to temperatures close to 700 °C decomposes into molecular hydrogen and phosphorus (P4) and then the reaction products are delivered through a vapor line to the discharge chamber. Experimental data are presented reflecting the influence of the discharge parameters and temperature of the dissociator heater on the mass-charge state of the ion beam.

  20. Main Magnetic Focus Ion Source: II. The first investigations at 10 keV

    CERN Document Server

    Ovsyannikov, V P

    2015-01-01

    The basic principles of design for the compact ion source of new generation are presented. The device uses the local ion trap created by the axial electron beam rippled in a thick magnetic lens. In accordance with this feature, the ion source is given the name main magnetic focus ion source. The experimental evidences for the production of Ir$^{59+}$, Xe$^{44+}$, and Ar$^{16+}$ ions are obtained. The control over depth of the local ion trap is shown to be feasible.

  1. Effects of Dietary Energy Sources on Post Mortem Glycolysis, Meat Quality and Muscle Fibre Type Transformation of Finishing Pigs.

    Science.gov (United States)

    Li, Yanjiao; Li, Jiaolong; Zhang, Lin; Yu, Changning; Lin, Meng; Gao, Feng; Zhou, Guanghong; Zhang, Yu; Fan, Yuanfang; Nuldnali, Lina

    2015-01-01

    Dietary energy source can influence muscle glycogen storage at slaughter. However, few studies have demonstrated whether the diet-induced change of muscle glycogen is achieved by the transformation of muscle fibre type. This study investigated the effects of dietary energy sources on meat quality, post mortem glycolysis and muscle fibre type transformation of finishing pigs. Seventy-two barrows with an average body weight of 65.0 ± 2.0 kg were selected and were allotted to three iso-energetic and iso-nitrogenous diets A, B or C, and each treatment consisted of three replicates (pens) of eight pigs each. Diet A contained 44.1% starch, 5.9% crude fat and 12.6% neutral detergent fiber (NDF); diet B contained 37.6% starch, 9.5% crude fat and 15.4% NDF; and diet C contained 30.9% starch, 14.3% crude fat and 17.8% NDF. The duration of the experiment was 28 days. After feed withdrawal 12 h, 24 pigs (eight per treatment) were slaughtered, samples from M. longissimus lumborum (LL) were collected for subsequent analysis. The results showed that pigs fed diet C had lesser average daily gain, average daily feed intake and back fat depth than those fed diet A (Ppigs fed diet A showed increased contents of lactate and greater glycolytic potential (GP) compared with those fed diet C (Ppigs fed diet C, than in pigs fed diet A. In addition, pigs fed diet C resulted in downregulation of miR23a and upregulation of miR409 and miR208b (Ppigs. This reduction of GP may be partially associated with the improvement of oxidative fibre composition in LL muscle, and the change in myofibre type may be correlated with the change in the miRNA expression.

  2. L-dehydroascorbic acid can substitute l-ascorbic acid as dietary vitamin C source in guinea pigs.

    Science.gov (United States)

    Frikke-Schmidt, Henriette; Tveden-Nyborg, Pernille; Lykkesfeldt, Jens

    2016-04-01

    Vitamin C deficiency globally affects several hundred million people and has been associated with increased morbidity and mortality in numerous studies. In this study, bioavailability of the oxidized form of vitamin C (l-dehydroascorbic acid or DHA)-commonly found in vitamin C containing food products prone to oxidation-was studied. Our aim was to compare tissue accumulation of vitamin C in guinea pigs receiving different oral doses of either ascorbate or DHA. In all tissues tested (plasma, liver, spleen, lung, adrenal glands, kidney, muscle, heart, and brain), only sporadic differences in vitamin C accumulation from ascorbate or DHA were observed except for the lowest dose of DHA (0.25mg/ml in the drinking water), where approximately half of the tissues had slightly yet significantly less vitamin C accumulation than from the ascorbate source. As these results contradicted data from rats, we continued to explore the ability to recycle DHA in blood, liver and intestine in guinea pigs, rats and mice. These investigations revealed that guinea pigs have similar recycling capacity in red blood cells as observed in humans, while rats and mice do not have near the same ability to reduce DHA in erythrocytes. In liver and intestinal homogenates, guinea pigs also showed a significantly higher ability to recycle DHA compared to rats and mice. These data demonstrate that DHA in guinea pigs-as in humans-is almost as effective as ascorbate as vitamin C source when it comes to taking up and storing vitamin C and further suggest that the guinea pig is superior to other rodents in modeling human vitamin C homeostasis.

  3. A compact source for bunches of singly charged atomic ions.

    Science.gov (United States)

    Murböck, T; Schmidt, S; Andelkovic, Z; Birkl, G; Nörtershäuser, W; Vogel, M

    2016-04-01

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 10(6) Mg(+) ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg(+) ions for sympathetic cooling of highly charged ions by laser-cooled (24)Mg(+).

  4. On-site application of air cleaner emitting plasma ion to reduce airborne contaminants in pig building

    Science.gov (United States)

    Cho, Man Su; Ko, Han Jong; Kim, Daekeun; Kim, Ki Youn

    2012-12-01

    The objective of this field study is to evaluate temporal reduction efficiency of air cleaner emitting plasma ion on airborne pollutants emitted from pig building. The operation principle of air cleaner based on plasma ion is that hydrogen atoms and oxygen ions combine to form hydroperoxyl radicals (HOO-), which surround and attach to surface of airborne microorganisms and eliminate them by breaking the hydrogen bond in their protein structure. In gaseous pollutants, it was found that there is no reduction effect of the air cleaner on ammonia and hydrogen sulfide (p > 0.05). In particulate pollutants, the air cleaner showed mean 79%(±6.1) and 78%(±3.0) of reduction efficiency for PM2.5. and PM1, respectively, compared to the control without air cleaner (p 0.05). In biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi by application of air cleaner were 22%(±6.6) and 25%(±8.7), respectively (p effect on PM2.5, PM1, airborne bacteria and airborne fungi among airborne pollutants distributed in pig building while it did not lead to significant reduction of ammonia and hydrogen sulfide.

  5. Production of low energy spread ion beams with multicusp sources

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y. [Lawrence Berkeley National Lab., CA (United States); Perkins, L.T. [Lawrence Berkeley National Lab., CA (United States); Gough, R.A. [Lawrence Berkeley National Lab., CA (United States); Hoffmann, M. [Lawrence Berkeley National Lab., CA (United States); Kunkel, W.B. [Lawrence Berkeley National Lab., CA (United States); Leung, K.N. [Lawrence Berkeley National Lab., CA (United States); Sarstedt, M. [Lawrence Berkeley National Lab., CA (United States); Vujic, J. [Lawrence Berkeley National Lab., CA (United States); Weber, M. [Lawrence Berkeley National Lab., CA (United States); Williams, M.D. [Lawrence Berkeley National Lab., CA (United States)

    1996-05-11

    The use of multicusp sources to generate ion beams with narrow energy spread has been investigated. It is found that the presence of a magnetic filter can reduce the longitudinal energy spread significantly. This is achieved by creating a uniform plasma potential distribution in the discharge chamber region, eliminating ion production in the extraction chamber and in the sheath of the exit aperture and by minimizing the probability of charge exchange processes in the extraction chamber. An energy spread as low as 1 eV has been measured. (orig.).

  6. Cesiated hollow cathodes in the multicusp ion source

    Science.gov (United States)

    Belchenko, Yu. I.; Oka, Y.; Hamabe, M.; Kaneko, O.; Krivenko, A.; Takeiri, Y.; Tsumori, K.; Osakabe, M.; Ikeda, K.; Asano, E.; Kawamoto, T.

    2002-02-01

    A cesiated hydrogen hollow cathode (CHC) was tested for plasma injection in the multicusp negative ion source (MS). The CHC arc with hydrogen feed and cesium seeding through the CHC volume was explored. One cathode unit (40 mm length, 19 mm in diameter, emission opening area 1-3 mm2) with no special cooling provided the MS discharge operation with direct current up to 30 A, and up to 60 A in the long-pulse mode. High efficiency of negative ion production in the MS discharge, driven by a CHC plasma injection was recorded.

  7. Production of low energy spread ion beams with multicusp sources

    Science.gov (United States)

    Y., Lee; Perkins, L. T.; Gough, R. A.; Hoffmann, M.; Kunkel, W. B.; N. Leung, K.; Sarstedt, M.; Vujic, J.; Weber, M.; Williams, M. D.

    1996-02-01

    The use of multicusp sources to generate ion beams with narrow energy spread has been investigated. It is found that the presence of a magnetic filter can reduce the longitudinal energy spread significantly. This is achieved by creating a uniform plasma potential distribution in the discharge chamber region, eliminating ion production in the extraction chamber and in the sheath of the exit aperture and by minimizing the probability of charge exchange processes in the extraction chamber. An energy spread as low as 1 eV has been measured.

  8. Effect of supplementing finishing pigs with different sources of chromium on performance and meat quality

    Directory of Open Access Journals (Sweden)

    Louise Manha Peres

    2014-07-01

    Full Text Available The objective was to evaluate the dietary supplementation of different sources of chromium (inorganic: chromium sulfate and chelated: chromium-methionine during the finishing period of pigs to obtain improvements in the animal performance, and carcass and meat quality. The statistical design was randomized blocks, where 44 barrows, with an initial weight 60.49±5.12 kg, were divided into four blocks (heavier, heavy, light and lighter according to initial weight. The experimental diets were isoenergetic and isonutrient, except for the chromium level. The treatments were divided as follows: control (without chromium, control + 200 ppb of inorganic chromium (chromium sulfate, and control + 200 ppb of chelated chromium (chromium-methionine. In the performance measures, the stall was considered the experimental unit and in the blood parameters, carcass and meat evaluations each animal constituted the experimental unit. Animals were slaughtered when they reached the final average weight of 107.23±5.23 kg. Blood samples were collected and tested for blood parameters (cholesterol, triglycerides and glucose as well as carcass quality (hot and cold weights, yield, loin-eye area, muscle depth and backfat thickness and meat quality (initial and final pH, drip loss, color, chemical composition and lipid oxidation parameters. Chromium-methionine supplementation provides a greater daily weight gain only compared with the animals that are not supplemented with chromium, because feed conversion is better as compared with the other treatments. After 24 hours of storage, the meat from pigs supplemented either with chromium-methionine or with chromium sulfate presents lower lipid oxidation than that from non-supplemented animals. However, after three days of storage, only chromim-methionine is effective in reducing lipid oxidation.

  9. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept

    OpenAIRE

    Melin, G.; Drentje, A. G.; Girard, A; Hitz, D.

    1999-01-01

    Abstract: An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An expression is derived for determining the ion temperature from the values of all extracted ion currents. One aim is to study the ion temperature behavior in argon plasmas without and with mixing different...

  10. The effect of biasing the plasma electrode on hydrogen ion formations in a multicusp ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ego, Hiroyasu; Iwashita, Yoshihisa (Kyoto Univ., Uji (Japan). Inst. for Chemical Research); Takekoshi, Hidekuni

    1992-03-01

    The plasma electrode covered with magnetic cusp fields acting as a magnetic filter was installed in a multicusp ion source. The formation processes of the negative and positive hydrogen ions in this source have been investigated when an electrostatic positive bias is applied to the plasma electrode with respect to the anode chamber. The dominant H[sup -] volume-production process is the recombinational attachment rather than the dissociative attachment when the bias voltage is more than +3V. This recombinational attachment improves the H[sup +] ratio in the extracted positive beam, keeping its current value. (author) 52 refs.

  11. Numerical simulation program of multicomponent ion beam transport from ECR ion source

    Institute of Scientific and Technical Information of China (English)

    MA Lei; SONG Ming-Tao; CAO Yun; ZHAO Hong-Wei; ZHANG Zi-Min; LI Xue-Qian; LI Jia-Cai

    2004-01-01

    In order to research multi-component ion beam transport process and improve transport efficiency, a special simulating program for ECR beam is becoming more and more necessary. We have developed a program written by Visual Basic to be dedicated to numerical simulation of the highly charged ion beam and to optimization of beam dynamics in transport line. In the program the exchange of electrons between highly charged ions and low chargedions or neutral atoms (residual gas in transport line) is taken into account, adopting classical molecular over-barrier model and Monte Carlo method, so the code can easily give the change of charge state distribution along the transmission line. The main advantage of the code is the ability to simultaneously simulate a large quantity of ions with different masses and charge states, and particularly, to simulate the loss of highly charged ions and the increase of low charged ions due to electron exchange in the whole transport process. Some simulations have been done to study the transmission line of LECR3[1] which is an ECR ion source for highly charged ion beam at IMP. Compared with experimental results, the simulations are considered to be successful.

  12. The Gridless Plasma Ion Source(GIS)for Plasma Ion Assisted Optical Coating

    Institute of Scientific and Technical Information of China (English)

    尤大伟; 李晓谦; 王宇; 林永昌

    2004-01-01

    High-quality optical coating is a key technology for modern optics. Ion-assisted deposition technology was used to improve the vaporized coating in 1980's. The GIS (gridless ion source), which is an advanced plasma source for producing a high-quality optical coating in large area, can produce a large area uniformity>1000 mm(diameter), a high ion current density ~ 0.5mA/cm2, 20 eV ~ 200 eV energetic plasma ions and can activate reactive gas and film atoms. Now we have developed a GIS system. The GIS and the plasma ion-assisted deposition technology are investigated to achieve a high-quality optical coating. The GIS is a high power and high current source with a power of I kW ~ 7.5 kW, a current of 10 A ~ 70 A and an ion density of 200μA/cm2 ~ 500μA/cm2. Because of the special magnetic structure, the plasma-ion extraction efficiency has been improved to obtain a maximum ion density of 500μA/cm2 in the medium power (~ 4 kW) level. The GIS applied is of a special cathode structure, so that the GIS operation can be maintained under a rather low power and the lifetime of cathode will be extended. The GIS has been installed in the LPSX-1200 type box coating system. The coated TiO2, SiO2 films such as antireflective films with the system have the same performance reported by Leybold Co, 1992, along with a controllable refractive index and film structure.

  13. Linac4 H{sup −} ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Lettry, J., E-mail: Jacques.lettry@cern.ch; Aguglia, D.; Andersson, P.; Bertolo, S.; Butterworth, A.; Coutron, Y.; Dallocchio, A.; David, N.; Chaudet, E.; Fink, D. A.; Garlasche, M.; Grudiev, A.; Guida, R.; Hansen, J.; Haase, M.; Jones, A.; Koszar, I.; Lallement, J.-B.; Lombardi, A. M.; Machado, C. [CERN-ABP, 1211 Geneva 23 (Switzerland); and others

    2016-02-15

    CERN’s 160 MeV H{sup −} linear accelerator (Linac4) is a key constituent of the injector chain upgrade of the Large Hadron Collider that is being installed and commissioned. A cesiated surface ion source prototype is being tested and has delivered a beam intensity of 45 mA within an emittance of 0.3 π ⋅ mm ⋅ mrad. The optimum ratio of the co-extracted electron- to ion-current is below 1 and the best production efficiency, defined as the ratio of the beam current to the 2 MHz RF-power transmitted to the plasma, reached 1.1 mA/kW. The H{sup −} source prototype and the first tests of the new ion source optics, electron-dump, and front end developed to minimize the beam emittance are presented. A temperature regulated magnetron H{sup −} source developed by the Brookhaven National Laboratory was built at CERN. The first tests of the magnetron operated at 0.8 Hz repetition rate are described.

  14. Design of the RF ion source for the ITER NBI

    Energy Technology Data Exchange (ETDEWEB)

    Marcuzzi, D. [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy)], E-mail: diego.marcuzzi@igi.cnr.it; Agostinetti, P.; Dalla Palma, M. [Consorzio RFX, Euratom-ENEA Association, Corso Stati Uniti 4, I-35127 Padova (Italy); Falter, H.D.; Heinemann, B.; Riedl, R. [Max-Planck-Institut fuer Plasmaphysik, D-85748 Garching (Germany)

    2007-10-15

    A radio frequency (RF) driven negative ion source has been designed for the ITER neutral beam injectors, as an alternative to the traditional arc driven solution. The main advantage of this technology is to avoid the presence of the filaments, that require periodic maintenance and consequently frequent shutdowns. The requirements for the ion source of the ITER NBI are to provide a uniform flux of D{sup -}/H{sup -} to the plasma grid of the accelerator that will result in a beam current of 40 A at 1 MeV. The present specification is for a filling pressure of 0.3 Pa. The ion source needs to provide 20/28 mA/cm{sup 2} D{sup -}/H{sup -} current density across the 0.58 m x 1.54 m aperture array for 3600 s. The source, consisting of a main chamber facing the plasma grid, of eight RF drivers and the auxiliary systems for power transfer, cooling and diagnostic purposes, is housed in the same quasi-cylindrical structure that supports the arc driven solution. Specific electric and hydraulic circuits have been designed and verified. In the paper the analyses performed for the design of the components are presented in detail.

  15. Status and operation of the Linac4 ion source prototypes.

    Science.gov (United States)

    Lettry, J; Aguglia, D; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Hatayama, A; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, Ø; Moyret, P; Nisbet, D; Nishida, K; O'Neil, M; Ohta, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Shibata, T; Steyaert, D; Thaus, N; Yamamoto, T

    2014-02-01

    CERN's Linac4 45 kV H(-) ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma, and pulsed high voltages are described. The first experimental results of two prototypes relying on 2 MHz RF-plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H(-) beam of 16-22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator, and chopper of Linac4.

  16. Status report of the ECR ion sources at the KVI

    CERN Document Server

    Drentje, A G; Kremers, H R; Meyer, D; Mulder, J; Sijbring, J

    1999-01-01

    At the moment three ECR ion sources are in operation at the KVI. One of these is being used as the ionizer section of the polarized ion (protons and deuterons) source POLIS; it runs at 2.5 GHz. In this paper the emphasis will be on the other two ECRISs, both being used for the production of highly charged ions. ECRIS3 is connected to the AGOR super-conducting Cyclotron. Beams of 12, 13C6+, 14N7+, 15N5+, 16O6+, 8+, 36Ar11+, 12+, 14+, 40Ar8+ and 3He2+, 4He2+ have been produced at various source voltages (16 - 29 kV), corresponding to a range of beam energies for experiments. The source is operating satisfactorily with sufficiently high beam intensities. Gas mixing is important for the high charge states of argon, where the best results have been obtained with 18O as a mixing gas. Since the AGOR cyclotron is used for the larger fraction of available beam time with (polarized) protons, the ECRIS3 set up is quite often available for test runs. ECRIS4 is connected to the five experimental set-ups of the Atomic Phys...

  17. Status and Operation of the Linac4 Ion Source Prototypes

    CERN Document Server

    Lettry, J; Andersson, P; Bertolo, S; Butterworth, A; Coutron, Y; Dallocchio, A; Chaudet, E; Gil-Flores, J; Guida, R; Hansen, J; Hatayama, A; Koszar, I; Mahner, E; Mastrostefano, C; Mathot, S; Mattei, S; Midttun, O; Moyret, P; Nisbet, D; Nishida, K; O’Neil, M; Ohta, M; Paoluzzi, M; Pasquino, C; Pereira, H; Rochez, J; Sanchez Alvarez, J; Sanchez Arias, J; Scrivens, R; Shibata, T; Steyaert, D; Thaus, N; Yamamoto, T

    2014-01-01

    CERN’s Linac4 45 kV H- ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma and pulsed high voltages are described. The first experimental results of two prototypes relying on 2MHz RF- plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H- beam of 16-22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator and chopper of Linac4.

  18. Status and operation of the Linac4 ion source prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Lettry, J., E-mail: Jacques.lettry@cern.ch; Aguglia, D.; Andersson, P.; Bertolo, S.; Butterworth, A.; Coutron, Y.; Dallocchio, A.; Chaudet, E.; Gil-Flores, J.; Guida, R.; Hansen, J.; Koszar, I.; Mahner, E.; Mastrostefano, C.; Mathot, S.; Mattei, S.; Midttun, Ø.; Moyret, P.; Nisbet, D.; O’Neil, M. [CERN, 1211 Geneva 23 (Switzerland); and others

    2014-02-15

    CERN's Linac4 45 kV H{sup −} ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma, and pulsed high voltages are described. The first experimental results of two prototypes relying on 2 MHz RF-plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H{sup −} beam of 16–22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator, and chopper of Linac4.

  19. When API Mass Spectrometry Meets Super Atmospheric Pressure Ion Sources.

    Science.gov (United States)

    Chen, Lee Chuin

    2015-01-01

    In a tutorial paper on the application of free-jet technique for API-MS, John Fenn mentioned that "…for a number of years and a number of reasons, it has been found advantageous in many situations to carry out the ionization process in gas at pressures up to 1000 Torr or more" (Int. J. Mass Spectrom. 200: 459-478, 2000). In fact, the first ESI mass spectrometer constructed by Yamashita and Fenn had a counter-flow curtain gas source at 1050 Torr (ca. 1.4 atm) to sweep away the neutral (J. Phys. Chem. 88: 4451-4459, 1984). For gaseous ionization using electrospray plume, theoretical analysis also shows that "super-atmospheric operation would be more preferable in space-charge-limited situations."(Int. J. Mass Spectrom. 300: 182-193, 2011). However, electrospray and the corona-based chemical ion source (APCI) in most commercial instrument are basically operated under an atmospheric pressure ambient, perhaps out of the concern of safety, convenience and simplicity in maintenance. Running the ion source at pressure much higher than 1 atm is not so common, but had been done by a number of groups as well as in our laboratory. A brief review on these ion sources will be given in this paper.

  20. A CW radiofrequency ion source for production of negative hydrogen ion beams for cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Kalvas, T.; Tarvainen, O.; Komppula, J.; Koivisto, H.; Tuunanen, J. [University of Jyväskylä, Department of Physics (Finland); Potkins, D.; Stewart, T.; Dehnel, M. P. [D-Pace, Inc., Nelson, B.C. Canada (Canada)

    2015-04-08

    A CW 13.56 MHz radiofrequency-driven ion source RADIS for production of H{sup −} and D{sup −} beams is under development for replacing the filament-driven ion source of the MCC30/15 cyclotron. The RF ion source has a 16-pole multicusp plasma chamber, an electromagnet-based magnetic filter and an external planar spiral RF antenna behind an AlN window. The extraction is a 5-electrode system with an adjustable puller electrode voltage for optimizing the beam formation, a water-cooled electron dump electrode and an accelerating einzel lens. At 2650 W of RF power, the source produces 1 mA of H{sup −} (2.6 mA/cm{sup 2}), which is the intensity needed at injection for production of 200 µA H{sup +} with the filament-driven ion source. A simple pepperpot device has been developed for characterizing the beam emittance. Plans for improving the power efficiency with the use of a new permanent magnet front plate is discussed.

  1. Multicusp ion source with external RF antenna for production of H- ions

    Science.gov (United States)

    Kalvas, T.; Hahto, S. K.; Vainionpää, J. H.; Leung, K. N.; Wilde, S. B.; Mandrillon, P.

    2007-08-01

    A multicusp ion source with modular design was developed at LBNL for production of H- ions. The source consists of a front plate, two multicusp front chambers, a quartz flange with external 3-loop RF antenna and a rear multicusp chamber. The source has LaB6 sputtering target at the rear chamber to lower the work function of the surfaces by coating them with LaB6 and an external cesium oven on the front plate. The front plate also has an integrated collar and filter magnets to cool plasma near the extraction. The collar also enables the use of cesium and LaB6 surface effects. The rear chamber is equipped with three vacuum feed-throughs for operation with two gases and a pressure measurement. Current density of over 10 mA/cm2 of H- has been measured with e/I- ratio being ˜100 when the source was operated with only 1000 W of cw RF power. Negative ion production was enhanced using cesium, Xe gas mixing and LaB6 deposition to the source surfaces. When the front plate with filter magnets is removed, the source produces large amounts of H+. Current density of 110 mA/cm2 with 1800 W RF power at 2.3 Pa source pressure was measured with over 90 % atomic species. A long operation lifetime is excepted as the external RF antenna is not exposed to plasma.

  2. A review of vacuum ARC ion source research at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Evans, P.J.; Noorman, J.T.; Watt, G.C. [ANSTO, Menai (Australia)

    1996-08-01

    The authors talk briefly describes the history and current status of vacuum arc ion source research at the Australian Nuclear Science and Technology Organization (ANSTO). In addition, the author makes some mention of the important role of previous Vacuum Arc Ion Source Workshops in fostering the development of this research field internationally. During the period 1986 - 89, a type of plasma centrifuge known as a vacuum arc centrifuge was developed at ANSTO as part of a research project on stable isotope separation. In this device, a high current vacuum arc discharge was used to produce a metal plasma which was subsequently rotated in an axial magnetic field. The high rotational speeds (10{sup 5} - 10{sup 6} rad sec{sup {minus}1}) achievable with this method produce centrifugal separation of ions with different mass:charge ratios such as isotopic species. The first portent of things to come occurred in 1985 when Dr. Ian Brown visited ANSTO`s Lucas Heights Research Laboratories and presented a talk on the metal vapour vacuum arc (MEVVA) ion source which had only recently been invented by Brown and co-workers, J. Galvin and R. MacGill, at Lawrence Berkeley Laboratory. For those of us involved in vacuum arc centrifuge research, this was an exciting development primarily because the metal vapour vacuum arc plasma source was common to both devices. Thus, a type of arc, which had since the 1930`s been extensively investigated as a means of switching high current loads, had found wider application as a useful plasma source.

  3. Proceedings of the 10th international workshop on ECR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, F W; Kirkpatrick, M I [eds.

    1991-01-01

    This report contains papers on the following topics: Recent Developments and Future Projects on ECR Ion Sources; Operation of the New KVI ECR Ion Source at 10 GHz; Operational Experience and Status of the INS SF-ECR Ion Source; Results of the New ECR4'' 14.5 GHz ECRIS; Preliminary Performance of the AECR; Experimental Study of the Parallel and Perpendicular Particle Losses from an ECRIS Plasma; Plasma Instability in Electron Cyclotron Resonance Heated Ion Sources; The Hyperbolic Energy Analyzer; Status of ECR Source Development; The New 10 GHz CAPRICE Source; First Operation of the Texas A M ECR Ion Source; Recent Developments of the RIKEN ECR Ion Sources; The 14 GHz CAPRICE Source; Characteristics and Potential Applications of an ORNL Microwave ECR Multicusp Plasma Ion Source; ECRIPAC: The Production and Acceleration of Multiply Charged Ions Using an ECR Plasma; ECR Source for the HHIRF Tandem Accelerator; Feasibility Studies for an ECR-Generated Plasma Stripper; Production of Ion Beams by using the ECR Plasmas Cathode; A Single Stage ECR Source for Efficient Production of Radioactive Ion Beams; The Single Staged ECR Source at the TRIUMF Isotope Separator TISOL; The Continuous Wave, Optically Pumped H{sup {minus}} Source; The H{sup +} ECR Source for the LAMPF Optically Pumped Polarized Ion Source; Present Status of the Warsaw CUSP ECR Ion Source; An ECR Source for Negative Ion Production; GYRAC-D: A Device for a 200 keV ECR Plasma Production and Accumulation; Status Report of the 14.4 GHZ ECR in Legnaro; Status of JYFL-ECRIS; Report on the Uppsala ECRIS Facility and Its Planned Use for Atomic Physics; A 10 GHz ECR Ion Source for Ion-Electron and Ion-Atom Collision Studies; and Status of the ORNL ECR Source Facility for Multicharged Ion Collision Research.

  4. Langmuir probe studies on a RF ion source for NBI

    Energy Technology Data Exchange (ETDEWEB)

    McNeely, P. E-mail: p.mcneely@ipp.mpg.de; Heineman, B.; Kraus, W.; Riedl, R.; Speth, E.; Vollmer, O

    2001-10-01

    IPP Garching has been developing a RF ion source for H{sup -} production. In order to improve the data quality a new scanning probe system with passive RF compensation has been installed on the Type VI ion source on the BATMAN test stand. Using this probe, measurements have been carried out to study changes to the plasma parameters (electron density, electron temperature, and plasma potential) due to variation in the source operating conditions. The data were collected at a source pressure of 0.5 Pa and with 60{+-}5 kW applied RF power. Presented are some of the results of these measurements, focusing on the effect of: argon seeding, addition of Cs to the source, and the newly added Faraday screen. The electron density behaves in a fashion that agrees with the theory of ambipolar diffusion. Typically there is little change to the average electron energy observed regardless of which effect is considered. The plasma potential shows the most significant changes with external source conditions, both in value for all cases and shape when the Faraday screen was added.

  5. rf-driven ion sources for industrial applications (invited) (abstract)a)

    Science.gov (United States)

    Leung, Ka-Ngo

    2008-02-01

    The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly developed combined rf ion-electron beam unit improves greatly the performance of the secondary ion mass spectrometry tool. (3) For neutron production, rf ion source is a major component of compact, high flux D-D, D-T, or T-T neutron generators. These neutron sources are now being employed in boron neutron capture therapy (BNCT) as well as in neutron imaging and material interrogation. (4) Large area rf-driven ion source will be used in an industrial design neutral beam diagnostic system for probing fusion plasmas. Such sources can be easily scaled to provide large ion beam current for future fusion reactor applications.

  6. Influence of Temperature, Source, and Serotype on Biofilm Formation of Salmonella enterica Isolates from Pig Slaughterhouses.

    Science.gov (United States)

    Piras, Francesca; Fois, Federica; Consolati, Simonetta Gianna; Mazza, Roberta; Mazzette, Rina

    2015-10-01

    Quantitative assessment of in vitro biofilm formation by 40 Salmonella enterica isolates isolated in pig abattoirs from animal and environmental sources (surfaces in contact and not in contact with meat) and classified in eight seroytpes was carried out by using a microtiter plate assay with spectrophotometric reading (optical density at 620 nm). Biofilm-forming ability was statistically correlated with the temperature of incubation (22 and 35°C), the source of the isolates, and the antimicrobial resistance profile. After incubation at 35°C, 9 isolates (22.5%) were classified as weak biofilm producers. After incubation at 22°C, 25 isolates (62.5%) were classified as weak producers and 3 (7.5%) as moderate producers. The quantity of biofilm formed after incubation at 22°C was significantly higher (P < 0.01) than at 35°C. This result is notable because 22°C is a common temperature in meat processing facilities and in slaughterhouses. At 35°C, isolates detected from surfaces in contact with meat showed significantly higher (P < 0.1) optical density values compared to isolates from other samples, highlighting the risk of cross-contamination for carcasses and offal. No correlation was detected between quantity of biofilm and serotype or between biofilm formation and resistance to antimicrobials.

  7. High dielectric constant ceramics for ion-electron sources

    CERN Document Server

    Boscolo, I

    2002-01-01

    Ferroelectric disks, coated with proper electrodes, can easily produce a dense plasma cloud when excited with a high-voltage pulse. This plasma can be a source of either electrons or ions depending on the sign of the extracting field set in front of the disk. We present the behavior of the disks operating at high frequency as emitters of both electrons and ions in two experimental configurations: (a) without and (b) with two screening grids. These two screening grids are inserted when the plasma must be confined within the cathode region. The system is capable of providing ion pulses of a few hundred milliamperes, whose length can range from a hundred nanoseconds to dozen microseconds. The electron pulses of energetic electrons have typically an amplitude higher than a couple of amperes. Tests at MHz repetition rate were positive as for stable operation.

  8. Plasma shape control by pulsed solenoid on laser ion source

    Science.gov (United States)

    Sekine, M.; Ikeda, S.; Romanelli, M.; Kumaki, M.; Fuwa, Y.; Kanesue, T.; Hayashizaki, N.; Lambiase, R.; Okamura, M.

    2015-09-01

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  9. Plasma shape control by pulsed solenoid on laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Sekine, M. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Ikeda, S. [Tokyo Institute of Technology, Yokohama, Kanagawa 226-8502 (Japan); RIKEN, Wako, Saitama 351-0198 (Japan); Romanelli, M. [Cornell University, Ithaca, NY 14850 (United States); Kumaki, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Waseda University, Shinjuku, Tokyo 169-0072 (Japan); Fuwa, Y. [RIKEN, Wako, Saitama 351-0198 (Japan); Kyoto University, Uji, Kyoto 611-0011 (Japan); Kanesue, T. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Hayashizaki, N. [Tokyo Institute of Technology, Meguro-ku, Tokyo 2-12-1 (Japan); Lambiase, R. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Okamura, M. [RIKEN, Wako, Saitama 351-0198 (Japan); Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2015-09-21

    A Laser ion source (LIS) provides high current heavy ion beams with a very simple mechanical structure. Plasma is produced by a pulsed laser ablation of a solid state target and ions are extracted by an electric field. However, it was difficult to manipulate the beam parameters of a LIS, since the plasma condition could only be adjusted by the laser irradiation condition. To enhance flexibility of LIS operation, we employed a pulsed solenoid in the plasma drift section and investigated the effect of the solenoid field on singly charged iron beams. The experimentally obtained current profile was satisfactorily controlled by the pulsed magnetic field. This approach may also be useful to reduce beam emittance of a LIS.

  10. Proceedings of the workshop on ion source issues relevant to a pulsed spallation neutron source: Part 1: Workshop summary

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, L.; Leung, K.N.; Alonso, J. [eds.

    1994-10-01

    The workshop reviewed the ion-source requirements for high-power accelerator-driven spallation neutron facilities, and the performance of existing ion sources. Proposals for new facilities in the 1- to 5-MW range call for a widely differing set of ion-source requirements. For example, the source peak current requirements vary from 40 mA to 150 mA, while the duty factor ranges from 1% to 9%. Much of the workshop discussion centered on the state-of-the-art of negative hydrogen ion source (H{sup {minus}}) technology and the present experience with Penning and volume sources. In addition, other ion source technologies, for positive ions or CW applications were reviewed. Some of these sources have been operational at existing accelerator complexes and some are in the source-development stage on test stands.

  11. The application of alumino silicate alkali ion sources to the study of ion desorption of surface gas

    CERN Document Server

    Jones, A W; Williams, E M

    1974-01-01

    Investigations are described which illustrate the compatibility of alumino silicate alkali ion sources with an UHV ( approximately 10/sup -11/) vacuum environment. The application of the sources to the determination of ion desorption efficiency of surface gas is demonstrated, as well as their use as a basis of a technique of ion stimulated gas analysis. (12 refs).

  12. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; ET AL.

    2005-02-28

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linac. The highly successful development of an EBIS at BNL now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based pre-injectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The new RFQ and Linac that are used to accelerate beams from the EBIS to an energy sufficient for injection into the Booster are both very similar to existing devices already in operation at other facilities. Injection into the Booster will occur at the same location as the existing injection from the Tandem.

  13. Effect of electrode materials on a negative ion production in a cesium seeded negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Takashi; Morishita, Takutoshi; Kashiwagi, Mieko; Hanada, Masaya; Iga, Takashi; Inoue, Takashi; Watanabe, Kazuhiro; Imai, Tsuyoshi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Wada, Motoi [Doshisha Univ., Kyoto (Japan)

    2003-03-01

    Effects of plasma grid materials on the negative ion production efficiency in a cesium seeded ion source have been experimentally studied. Grid materials of Au, Ag, Cu, Ni, and Mo were examined. A 2.45 GHz microwave ion source was utilized in the experiment to avoid contamination of tungsten from filament cathode. Relations between the negative ion currents and work functions of the grid were measured for these materials. Influence of the contamination by tungsten on the grid was also investigated. If was clarified that the negative ion production efficiency was determined only by the work function of the grid. The efficiency did not depend on the material itself. The lowest work function of 1.42 eV was obtained for Au grid with Cs, and a high H{sup -} production efficiency of 20.7 mA/kW was measured. This efficiency is about 1.3 times larger than that of Cs/Mo and Cs/Cu. Further improvement of the production efficiency was observed by covering the plasma grid with tungsten and cesium simultaneously. Such co-deposition of W and Cs on the plasma grid produced the negative ion production efficiency of 1.7 times higher than that from the tungsten grid simply covered with Cs. (author)

  14. ELECTRON BEAM ION SOURCE PREINJECTOR PROJECT (EBIS) CONCEPTUAL DESIGN REPORT.

    Energy Technology Data Exchange (ETDEWEB)

    ALESSI, J.; BARTON, D.; BEEBE, E.; GASSNER, D.; GRANDINETTI, R.; HSEUH, H.; JAVIDFAR, A.; KPONOU, A.; LAMBIASE, R.; LESSARD, E.; LOCKEY, R.; LODESTRO, V.; MAPES, M.; MIRABELLA, D.; NEHRING, T.; OERTER, B.; PENDZICK, A.; PIKIN, A.; RAPARIA, D.; RITTER, J.; ROSER, T.; RUSSO, T.; SNYDSTRUP, L.; WILINSKI, M.; ZALTSMAN, A.; ZHANG, S.

    2005-09-01

    This report describes a new heavy ion pre-injector for the Relativistic Heavy Ion Collider (RHIC) based on a high charge state Electron Beam Ion Source (EBIS), a Radio Frequency Quadrupole (RFQ) accelerator, and a short Linear accelerator (Linac). The highly successful development of an EBIS at Brookhaven National Laboratory (BNL) now makes it possible to replace the present pre-injector that is based on an electrostatic Tandem with a reliable, low maintenance Linac-based pre-injector. Linac-based preinjectors are presently used at most accelerator and collider facilities with the exception of RHIC, where the required gold beam intensities could only be met with a Tandem until the recent EBIS development. EBIS produces high charge state ions directly, eliminating the need for the two stripping foils presently used with the Tandem. Unstable stripping efficiencies of these foils are a significant source of luminosity degradation in RHIC. The high reliability and flexibility of the new Linac-based pre-injector will lead to increased integrated luminosity at RHIC and is an essential component for the long-term success of the RHIC facility. This new pre-injector, based on an EBIS, also has the potential for significant future intensity increases and can produce heavy ion beams of all species including uranium beams and, as part of a future upgrade, might also be used to produce polarized {sup 3}He beams. These capabilities will be critical to the future luminosity upgrades and electron-ion collisions in RHIC. The proposed pre-injector system would also provide for a major enhancement in capability for the NASA Space Radiation Laboratory (NSRL), which utilizes heavy-ion beams from the RHIC complex. EBIS would allow for the acceleration of all important ion species for the NASA radiobiology program, such as, helium, argon, and neon which are unavailable with the present Tandem injector. In addition, the new system would allow for very rapid switching of ion species for

  15. Ion collector design for an energy recovery test proposal with the negative ion source NIO1

    Energy Technology Data Exchange (ETDEWEB)

    Variale, V., E-mail: vincenzo.variale@ba.infn.it [INFN-BA, Via Orabona 4, I-70125 Bari (Italy); Cavenago, M. [INFN – LNL, viale dell’Università 2, I-35020 Legnaro (PD) (Italy); Agostinetti, P.; Sonato, P.; Zanotto, L. [Consorzio RFX, Corso Stati Uniti 4, I-35127 Padova (Italy)

    2016-02-15

    Commercial viability of thermonuclear fusion power plants depends also on minimizing the recirculation power used to operate the reactor. The neutral beam injector (NBI) remains one of the most important method for plasma heating and control. For the future fusion power plant project DEMO, a NBI wall plug efficiency at least of 0.45 is required, while efficiency of present NBI project is about 0.25. The D{sup −} beam from a negative ion source is partially neutralized by a gas cell, which leaves more than 40% of energy in residual beams (D{sup −} and D{sup +}), so that an ion beam energy recovery system can significantly contribute to optimize efficiency. Recently, the test negative ion source NIO1 (60 keV, 9 beamlets with 15 mA H{sup −} each) has been designed and built at RFX (Padua) for negative ion production efficiency and the beam quality optimization. In this paper, a study proposal to use the NIO1 source also for a beam energy recovery test experiment is presented and a preliminary design of a negative ion beam collector with simulations of beam energy recovery is discussed.

  16. Ion collector design for an energy recovery test proposal with the negative ion source NIO1.

    Science.gov (United States)

    Variale, V; Cavenago, M; Agostinetti, P; Sonato, P; Zanotto, L

    2016-02-01

    Commercial viability of thermonuclear fusion power plants depends also on minimizing the recirculation power used to operate the reactor. The neutral beam injector (NBI) remains one of the most important method for plasma heating and control. For the future fusion power plant project DEMO, a NBI wall plug efficiency at least of 0.45 is required, while efficiency of present NBI project is about 0.25. The D(-) beam from a negative ion source is partially neutralized by a gas cell, which leaves more than 40% of energy in residual beams (D(-) and D(+)), so that an ion beam energy recovery system can significantly contribute to optimize efficiency. Recently, the test negative ion source NIO1 (60 keV, 9 beamlets with 15 mA H(-) each) has been designed and built at RFX (Padua) for negative ion production efficiency and the beam quality optimization. In this paper, a study proposal to use the NIO1 source also for a beam energy recovery test experiment is presented and a preliminary design of a negative ion beam collector with simulations of beam energy recovery is discussed.

  17. Laser desorption lamp ionization source for ion trap mass spectrometry.

    Science.gov (United States)

    Wu, Qinghao; Zare, Richard N

    2015-01-01

    A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds.

  18. Spectroscopic applications of the ISOLDE laser ion source

    CERN Document Server

    Sebastian, V; Fedosseev, V; Georg, U; Huber, G; Jading, Y; Jonsson, O; Köster, U; Koizumi, M; Kratz, K L; Kugler, E; Lettry, Jacques; Mishin, V I; Ravn, H L; Tamburella, C; Wöhr, A

    1998-01-01

    At the ISOLDE facility radioactive ion beams are produced via proton induced reactions in a target which is connected to a laser ion source. For beryllium a two step excitation scheme with laser light at wavelengths of lambda =235 nm and lambda =297 nm has been developed. Efficient laser ionization of beryllium was achieved with a new optical set-up using frequency tripling with two non-linear BBO crystals to generate laser light in the ultraviolet for the first excitation step. The second step was optimized to reach the 2p/sup 2 1/S/sub 0/ autoionizing state for high ionization efficiency. The isotope shift of /sup 7,9,10,11,12,14/Ba could be measured by tuning the wavelength of the first step. The laser ion source has also been used for the preparation of neutron-rich silver ion beams. Tuning the laser frequency of the first step it was possible to ionize selectively low- and high spin isomers of silver isotopes via the hyperfine structure. In both cases it was demonstrated that laser spectroscopy of exotic...

  19. Extraction of ions and electrons from audio frequency plasma source

    Directory of Open Access Journals (Sweden)

    N. A. Haleem

    2016-09-01

    Full Text Available Herein, the extraction of high ion / electron current from an audio frequency (AF nitrogen gas discharge (10 – 100 kHz is studied and investigated. This system is featured by its small size (L= 20 cm and inner diameter = 3.4 cm and its capacitive discharge electrodes inside the tube and its high discharge pressure ∼ 0.3 Torr, without the need of high vacuum system or magnetic fields. The extraction system of ion/electron current from the plasma is a very simple electrode that allows self-beam focusing by adjusting its position from the source exit. The working discharge conditions were applied at a frequency from 10 to 100 kHz, power from 50 – 500 W and the gap distance between the plasma meniscus surface and the extractor electrode extending from 3 to 13 mm. The extracted ion/ electron current is found mainly dependent on the discharge power, the extraction gap width and the frequency of the audio supply. SIMION 3D program version 7.0 package is used to generate a simulation of ion trajectories as a reference to compare and to optimize the experimental extraction beam from the present audio frequency plasma source using identical operational conditions. The focal point as well the beam diameter at the collector area is deduced. The simulations showed a respectable agreement with the experimental results all together provide the optimizing basis of the extraction electrode construction and its parameters for beam production.

  20. Negative hydrogen ion source research and beam parameters for accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Zolkin, Timofey V.; /Fermilab

    2006-09-01

    H{sup -} beams are useful for multi-turn charge-exchange stripping injection into circular accelerators. Studies on a modified ion source for this purpose are presented. This paper includes some theory about a H{sup -} magnetron discharge, ion-electron emission, emittance and problems linked with emittance measurement and calculations. Investigated parameters of the emittance probe for optimal performance give a screen voltage of 150 V and a probe step of about 5 mil. Normalized 90% emittance obtained for this H{sup -} source is 0.22 {pi} mm-mr, for an extraction voltage of 18 kV at a beam energy of 30 keV and a beam current of 11 mA.

  1. Autopilot regulation for the Linac4 H- ion source

    Science.gov (United States)

    Voulgarakis, G.; Lettry, J.; Mattei, S.; Lefort, B.; Costa, V. J. Correia

    2017-08-01

    Linac4 is a 160 MeV H- linear accelerator part of the upgrade of the LHC injector chain. Its cesiated surface H- source is designed to provide a beam intensity of 40-50mA. It is operated with periodical Cs-injection at typically 30 days intervals [1] and this implies that the beam parameters will slowly evolve during operation. Autopilot is a control software package extending CERN developed Inspector framework. The aim of Autopilot is to automatize the mandatory optimization and cesiation processes and to derive performance indicators, thus keeping human intervention minimal. Autopilot has been developed by capitalizing on the experience from manually operating the source. It comprises various algorithms running in real-time, which have been devised to: • Optimize the ion source performance by regulation of H2 injection, RF power and frequency. • Describe the performance of the source with performance indicators, which can be easily understood by operators. • Identify failures, try to recover the nominal operation and send warning in case of deviation from nominal operation. • Make the performance indicators remotely available through Web pages.Autopilot is at the same level of hierarchy as an operator, in the CERN infrastructure. This allows the combination of all ion source devices, providing the required flexibility. Autopilot is executed in a dedicated server, ensuring unique and centralized control, yet allowing multiple operators to interact at runtime, always coordinating between them. Autopilot aims at flexibility, adaptability, portability and scalability, and can be extended to other components of CERN's accelerators. In this paper, a detailed description of the Autopilot algorithms is presented, along with first results of operating the Linac4 H- Ion Source with Autopilot.

  2. Status report of the JYFL-ECR ion sources

    CERN Document Server

    Ärje, J; Seppälä, R; Hyvönen, H; Liukkonen, E; Heikkinen, P; Nieminen, V; Ranttila, K; Hänninen, V; Lassila, A; Pakarinen, J; Koivisto, H; Xie, Z Q

    1999-01-01

    "Ion beam cocktails" are mixtures of ions with near-identical charge-to-mass ratios. In conjunction with the JYFL-ECRIS, the K130-cyclotron acts as a mass analyzer: the switch from one ion to another within the same cocktail is simple and fast. In the case of the first ion beam cocktail, the oxygen and argon gases were mixed into the gas feed line. At the same time the magnesium and iron ion beams were produced using the MIVOC method. Magnesocene and ferrocene compounds were both mixed into the MIVOC chamber. This capability is especially useful in the study of single event effects (SEE) in space electronics. All gaseous elements from H to Xe can be produced. The non-gaseous elements produced so far are C, Mg, Al, Si, S, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn and Ge. A major technical modification since the construction (in 1990) of the JYFL-ECRIS was made in January 98: a negatively biased disc replaces now the first plasma stage. After a couple of months experience with the modified source the change was found to b...

  3. The microwave absorption of ceramic-cup microwave ion source

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    An experiment system of ceramic-cup microwave ion source has been built here. Its microwave absorption efficiency as a function of the magnetic field and the pressure is presented. When the microwave incident power is 300~500W the microwave absorption efficiencies are more than 90% if the system is optimized and the magnetic field at the microwave window is 0.095T.

  4. Progress of Target/Ion Source for Radioactive Beam

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    An ISOL test bench which uses proton beam from HL-13 Tandem to generate radioactive ion beamhas been set up and primary off line test has been carried out. The effects of magnetic field, anode voltage,cathode current and flax of feed-in gas on ionization efficiency have been investigated. The results showthe overal ionization efficiency of the source is greater than 0.7%. The effort to improve the overallefficiency is still in progress.

  5. Conceptional Design of the Laser Ion Source based Hadrontherapy Facility

    OpenAIRE

    Xie, Xiucui; Song, Mingtao; Zhang, Xiaohu

    2013-01-01

    Laser ion source (LIS), which can provide carbon beam with highly stripped state (C6+) and high intensity (several tens mA), would significantly change the overall design of the hadrontherapy facility. A LIS based hadrontherapy facility is proposed with the advantage of short linac length, simple injection scheme and small synchrotron size. With the experience from the DPIS and HITFiL project that had conducted in IMP, a conceptional design of the LIS based hadrontherapy facility will be pres...

  6. Development of a compact multicusp ion source of He+

    Science.gov (United States)

    Nishiura, M.; Sasao, M.; Wada, M.; Hamabe, M.; Kuroda, T.; Guharay, S. K.

    2000-02-01

    A filament-type helium ion source has been developed for the purpose of alpha particle diagnostics and as a test beam for electrostatic quadrupole transport experiments. We have obtained preliminary results of He+ beam current, ˜60 mA/cm2. The normalized brightness of this beam is ˜1010A/(m rad)2. The normalized emittance (90%) measured by multislit faraday cup emittance meter is ˜0.6 mm mrad below 100 V, 10 A arc discharge. The effects of plasma parameters in the source on the beam emittance and on the beam perveance are discussed.

  7. Development of a versatile multiaperture negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Cavenago, M. [INFN-LNL, viale dell' Universita n.2, I-35020 Legnaro (Padova) (Italy); Kulevoy, T.; Petrenko, S. [INFN-LNL, viale dell' Universita n.2, I-35020 Legnaro (Padova) (Italy); ITEP, B. Cheremushkinskaya 25, 117218 Moscow (Russian Federation); Serianni, G.; Antoni, V.; Bigi, M.; Fellin, F.; Recchia, M.; Veltri, P. [Consorzio RFX, Associazione Euratom-ENEA sulla fusione, c.so S. Uniti 4, 35127 Padova (Italy)

    2012-02-15

    A 60 kV ion source (9 beamlets of 15 mA each of H{sup -}) and plasma generators are being developed at Consorzio RFX and INFN-LNL, for their versatility in experimental campaigns and for training. Unlike most experimental sources, the design aimed at continuous operation. Magnetic configuration can achieve a minimum |B| trap, smoothly merged with the extraction filter. Modular design allows for quick substitution and upgrading of parts such as the extraction and postacceleration grids or the electrodes in contact with plasma. Experiments with a radio frequency plasma generator and Faraday cage inside the plasma are also described.

  8. RF sources for ITER Ion Cyclotron H and CD system

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, F., E-mail: fabienne.kazarian@iter.org [ITER Organization, CS 90 046, 13067 Sain-Paul-Les-Durance (France); Beaumont, B.; Arambhadiya, B.; Gassmann, T.; Lamalle, Ph.; Rathi, D. [ITER Organization, CS 90 046, 13067 Sain-Paul-Les-Durance (France); Mukherjee, A.; Ajesh, P.; Machchhar, H.; Patadia, D.; Patel, M.; Rajnish, K.; Singh, R.; Suthar, G.; Trivedi, R. [ITER India, IPR, Bhat, Gandhinagar 382428, Gujarat (India); Kumazawa, R.; Seki, T.; Saito, K.; Kasahara, H.; Mutoh, T. [National Institute for Fusion Science, Toki 509-5292 (Japan)

    2011-10-15

    The Ion Cyclotron Heating and Current Drive (IC H and CD) system for ITER will provide 20 MW to the plasma. The associated Radio Frequency (RF) source system has to be compliant with all operation modes foreseen in that frame. Their specifications are fully described in this paper and constraints on IC RF source components are detailed, in particular concerning the final stage tube of the amplifier. Results of tests performed under a collaborative work at the National Institute for Fusion Science (NIFS) facility are presented. Consequences on the procurement process by ITER India (II) are deduced.

  9. Beam optics optimization of a negative-ion sputter source

    Indian Academy of Sciences (India)

    F Osswald; R Rebmeister

    2002-11-01

    A negative-ion sputter source has been studied in order to increase the beam intensity delivered by the Vivitron tandem injector. The aim was to characterize the influence on the beam intensity of some factors related to the configuration of the source such as the shape of the target holder, the target surface topography and the anode/cathode voltage. The paper reports the results carried out by experimentation on a test facility and on the injector itself as well as the investigations performed with computer simulations.

  10. Blurring the boundaries between ion sources: The application of the RILIS inside a FEBIAD type ion source at ISOLDE

    Energy Technology Data Exchange (ETDEWEB)

    Day Goodacre, T., E-mail: thomas.day.goodacre@cern.ch [CERN, CH-1211 Geneva 23 (Switzerland); School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Billowes, J. [School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Catherall, R. [CERN, CH-1211 Geneva 23 (Switzerland); Cocolios, T.E. [School of Physics and Astronomy, The University of Manchester, Manchester M13 9PL (United Kingdom); Crepieux, B. [CERN, CH-1211 Geneva 23 (Switzerland); Fedorov, D.V. [Petersburg Nuclear Physics Institute, 188350 Gatchina (Russian Federation); Fedosseev, V.N. [CERN, CH-1211 Geneva 23 (Switzerland); Gaffney, L.P. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); Giles, T.; Gottberg, A.; Lynch, K.M.; Marsh, B.A.; Mendonça, T.M. [CERN, CH-1211 Geneva 23 (Switzerland); Ramos, J.P. [CERN, CH-1211 Geneva 23 (Switzerland); Laboratory of Powder Technology, EPFL, CH-1015 Lausanne (Switzerland); Rossel, R.E. [CERN, CH-1211 Geneva 23 (Switzerland); Institut für Physik, Johannes Gutenberg Universität, D-55099 Mainz (Germany); Faculty of Design, Computer Science and Media, Hochschule RheinMain, 65197 Wiesbaden (Germany); Rothe, S. [CERN, CH-1211 Geneva 23 (Switzerland); Sels, S.; Sotty, C. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); Stora, T. [CERN, CH-1211 Geneva 23 (Switzerland); Van Beveren, C. [KU Leuven, Instituut voor Kern- en Stralingsfysica, 3001 Leuven (Belgium); and others

    2016-06-01

    For the first time, the laser resonance photo-ionization technique has been applied inside a FEBIAD-type ion source at an ISOL facility. This was achieved by combining the ISOLDE RILIS with the ISOLDE variant of the FEBIAD ion source (the VADIS) in a series of off-line and on-line tests at CERN. The immediate applications of these developments include the coupling of the RILIS with molten targets at ISOLDE and the introduction of two new modes of FEBIAD operation: an element selective RILIS mode and a RILIS + VADIS mode for increased efficiency compared to VADIS mode operation alone. This functionality has been demonstrated off-line for gallium and barium and on-line for mercury and cadmium. Following this work, the RILIS mode of operation was successfully applied on-line for the study of nuclear ground state and isomer properties of mercury isotopes by in-source resonance ionization laser spectroscopy. The results from the first studies of the new operational modes, of what has been termed the Versatile Arc Discharge and Laser Ion Source (VADLIS), are presented and possible directions for future developments are outlined.

  11. Improvement in brightness of multicusp-plasma ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Q.; Jiang, X.; King, T-J.; Leung, K-N.; Standiford, K.; Wilde, S.B.

    2002-05-24

    The beam brightness of a multicusp-plasma ion source has been substantially improved by optimizing the source configuration and extractor geometry. The current density of a 2 keV He{sup +} beam extracted from a 7.5-cm-diameter source operating at 2.5 kW RF power is {approx}100 mA/cm{sup 2}, which is {approx}10 times larger than that of a beam extracted from a 5-cm-diameter source operating at 1 kW RF power. A smaller focused beam spot size is achieved with a counter-bored extractor instead of a conventional (''through-hole'') extractor, resulting another order of magnitude improvement in beam current density. Measured brightness can be as high as 440 A/cm{sup 2}Sr, which represents a 30 times improvement over prior work.

  12. The extraction of negative carbon ions from a volume cusp ion source

    Science.gov (United States)

    Melanson, Stephane; Dehnel, Morgan; Potkins, Dave; McDonald, Hamish; Hollinger, Craig; Theroux, Joseph; Martin, Jeff; Stewart, Thomas; Jackle, Philip; Philpott, Chris; Jones, Tobin; Kalvas, Taneli; Tarvainen, Olli

    2017-08-01

    Acetylene and carbon dioxide gases are used in a filament-powered volume-cusp ion source to produce negative carbon ions for the purpose of carbon implantation for gettering applications. The beam was extracted to an energy of 25 keV and the composition was analyzed with a spectrometer system consisting of a 90° dipole magnet and a pair of slits. It is found that acetylene produces mostly C2- ions (up to 92 µA), while carbon dioxide produces mostly O- with only trace amounts of C-. Maximum C2- current was achieved with 400 W of arc power and, the beam current and composition were found to be highly dependent on the pressure in the source. The beam properties as a function of source settings are analyzed, and plasma properties are measured with a Langmuir probe. Finally, we describe testing of a new RF H- ion source, found to produce more than 6 mA of CW H- beam.

  13. Investigation of helium ion production in constricted direct current plasma ion source with layered-glows

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yuna [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr [Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Park, Yeong-Shin [Samsumg Electronics Co. Ltd., Gyeonggi 445-701 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advance Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2014-02-15

    Generation of helium ions is experimentally investigated with a constricted direct current (DC) plasma ion source operated at layered-glow mode, in which electrons could be accelerated through multiple potential structures so as to generate helium ions including He{sup 2+} by successive ionization collisions in front of an extraction aperture. The helium discharge is sustained with the formation of a couple of stable layers and the plasma ball with high density is created near the extraction aperture at the operational pressure down to 0.6 Torr with concave cathodes. The ion beam current extracted with an extraction voltage of 5 kV is observed to be proportional to the discharge current and inversely proportional to the operating pressure, showing high current density of 130 mA/cm{sup 2} and power density of 0.52 mA/cm{sup 2}/W. He{sup 2+} ions, which were predicted to be able to exist due to multiple-layer potential structure, are not observed. Simple calculation on production of He{sup 2+} ions inside the plasma ball reveals that reduced operating pressure and increased cathode area will help to generate He{sup 2+} ions with the layered-glow DC discharge.

  14. Effect of Coulomb collision on the negative ion extraction mechanism in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I., E-mail: goto@ppl.appi.keio.ac.jp; Nishioka, S.; Abe, S.; Hatayama, A. [Graduate School of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Mattei, S.; Lettry, J. [CERN, 1211 Geneva 23 (Switzerland)

    2016-02-15

    To improve the H{sup −} ion beam optics, it is necessary to understand the energy relaxation process of surface produced H{sup −} ions in the extraction region of Cs seeded H{sup −} ion sources. Coulomb collisions of charged particles have been introduced to the 2D3V-PIC (two dimension in real space and three dimension in velocity space particle-in-cell) model for the H{sup −} extraction by using the binary collision model. Due to Coulomb collision, the lower energy part of the ion energy distribution function of H{sup −} ions has been greatly increased. The mean kinetic energy of the surface produced H{sup −} ions has been reduced to 0.65 eV from 1.5 eV. It has been suggested that the beam optics of the extracted H{sup −} ion beam is strongly affected by the energy relaxation process due to Coulomb collision.

  15. Development of a Bi+ source for heavy ion fusion

    Science.gov (United States)

    Weber, M.; Volk, K.; Beller, P.; Lakatos, A.; Maaser, A.; Klein, H.

    1998-02-01

    A volume source based on the high efficiency source is being developed for heavy ion production. Bismuth was chosen for exemplifying investigations because of its low melting point. The ion source is driven by an arc discharge ionizing bismuth atoms which are evaporated from an oven inside the source chamber. It has been optimized to produce a beam with a fraction of singly ionized bismuth above 92%. A multiaperture extraction system was built consisting of seven holes with a radius of 3 mm each. For that system, the perveance limit was achieved at a beam current of 70 mA and an extraction voltage of 27.5 kV. The corresponding emission current density amounts to 35 mA/cm2. This value was obtained for an arc power of only 280 W. Furthermore, the emittance of a beam extracted from the multiaperture extraction system has been determined with a high power emittance scanner. It amounts to 0.27π mm mrad (80%, normalized, 4 rms). In this case, the emittance of a single beam is 0.017π mm mrad. This article will give a detailed description of both the source and the experimental setup. In addition, various dependencies between the plasma parameters and the beam composition are presented.

  16. First experiments with the negative ion source NIO1

    Energy Technology Data Exchange (ETDEWEB)

    Cavenago, M., E-mail: cavenago@lnl.infn.it; Fagotti, E.; Minarello, A.; Poggi, M.; Sattin, M. [INFN-Laboratori Nazionali di Legnaro (LNL), v.le dell’Università 2, I-35020 Legnaro PD (Italy); Serianni, G.; Agostinetti, P.; Antoni, V.; Baltador, C.; Barbisan, M.; Baseggio, L.; Bigi, M.; Cervaro, V.; Degli Agostini, F.; Laterza, B.; Maniero, M.; Pasqualotto, R.; Ravarotto, D.; Recchia, M.; Sartori, E. [Consorzio RFX, Corso Stati Uniti 4, I-35127 Padova (Italy); and others

    2016-02-15

    Neutral Beam Injectors (NBIs), which need to be strongly optimized in the perspective of DEMO reactor, request a thorough understanding of the negative ion source used and of the multi-beamlet optics. A relatively compact radio frequency (rf) ion source, named NIO1 (Negative Ion Optimization 1), with 9 beam apertures for a total H{sup −} current of 130 mA, 60 kV acceleration voltage, was installed at Consorzio RFX, including a high voltage deck and an X-ray shield, to provide a test bench for source optimizations for activities in support to the ITER NBI test facility. NIO1 status and plasma experiments both with air and with hydrogen as filling gas are described. Transition from a weak plasma to an inductively coupled plasma is clearly evident for the former gas and may be triggered by rising the rf power (over 0.5 kW) at low pressure (equal or below 2 Pa). Transition in hydrogen plasma requires more rf power (over 1.5 kW)

  17. Improvements to the internal and external antenna H(-) ion sources at the Spallation Neutron Source.

    Science.gov (United States)

    Welton, R F; Dudnikov, V G; Han, B X; Murray, S N; Pennisi, T R; Pillar, C; Santana, M; Stockli, M P; Turvey, M W

    2014-02-01

    The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30-40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H(-) beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H(-) yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

  18. Digestible and metabolizable energy content of crude glycerin originating from different sources in nursery pigs.

    Science.gov (United States)

    Kerr, B J; Weber, T E; Dozier, W A; Kidd, M T

    2009-12-01

    The energy value of crude glycerin from different biodiesel production facilities was determined in nursery pigs (initial BW of 10.4 kg) to predict apparent DE and ME based on the composition of crude glycerin. Dietary treatments consisted of a basal diet, or diets containing crude glycerin from various biodiesel production facilities supplemented in the diet at approximately 9.1%. Because of bulk density differences, 2 glycerin products were supplemented at either 7.7 or 6.9%. In addition, soybean oil and lard were included at 6.7% as 2 dietary treatments to serve as positive controls. Each diet was fed twice daily to pigs in individual metabolism crates. After a 6-d adjustment period, a 4-d balance experiment was conducted. During the collection period, feces and urine were collected daily and stored at 0 degrees C until analysis. The GE of each test ingredient and diet and of urine and fecal samples from each pig were determined by isoperibol bomb calorimetry. The DE and ME values of crude glycerol were estimated by difference, whereby the DE and ME content of the basal diet was subtracted from the complete diet containing the test ingredient. Gross energy, DE, and ME of US Pharmacopeia grade glycerin were determined to be 4,325, 4,457, and 3,682 kcal/kg, respectively. In contrast, GE of the crude glycerin samples ranged from 3,173 to 6,021 kcal/kg, DE ranged from 3,022 to 5,228 kcal/kg, and ME ranged from 2,535 to 5,206 kcal/kg, reflecting the content of glycerol, methanol, and FFA in the crude glycerin. The GE, DE, and ME of soybean oil and lard were determined to be 9,443, 8,567, and 8,469 kcal/kg, and 9,456, 8,524, and 8,639 kcal/kg, respectively. The stepwise regression prediction of the ME in crude glycerin exhibited R(2) of only 0.41 [ME, kcal/kg (as-is basis) = (37.09 x % of glycerin) + (97.15 x % of fatty acids)], whereas prediction of GE achieved an R(2) of 0.99 [GE, kcal/kg (as-is basis) = -236 + (46.08 x % of glycerin) + (61.78 x % of methanol

  19. l-dehydroascorbic acid can substitute l-ascorbic acid as dietary vitamin C source in guinea pigs

    Directory of Open Access Journals (Sweden)

    Henriette Frikke-Schmidt

    2016-04-01

    Full Text Available Vitamin C deficiency globally affects several hundred million people and has been associated with increased morbidity and mortality in numerous studies. In this study, bioavailability of the oxidized form of vitamin C (l-dehydroascorbic acid or DHA—commonly found in vitamin C containing food products prone to oxidation—was studied. Our aim was to compare tissue accumulation of vitamin C in guinea pigs receiving different oral doses of either ascorbate or DHA. In all tissues tested (plasma, liver, spleen, lung, adrenal glands, kidney, muscle, heart, and brain, only sporadic differences in vitamin C accumulation from ascorbate or DHA were observed except for the lowest dose of DHA (0.25 mg/ml in the drinking water, where approximately half of the tissues had slightly yet significantly less vitamin C accumulation than from the ascorbate source. As these results contradicted data from rats, we continued to explore the ability to recycle DHA in blood, liver and intestine in guinea pigs, rats and mice. These investigations revealed that guinea pigs have similar recycling capacity in red blood cells as observed in humans, while rats and mice do not have near the same ability to reduce DHA in erythrocytes. In liver and intestinal homogenates, guinea pigs also showed a significantly higher ability to recycle DHA compared to rats and mice. These data demonstrate that DHA in guinea pigs—as in humans—is almost as effective as ascorbate as vitamin C source when it comes to taking up and storing vitamin C and further suggest that the guinea pig is superior to other rodents in modeling human vitamin C homeostasis.

  20. Improvements of the versatile multiaperture negative ion source NIO1

    Science.gov (United States)

    Cavenago, M.; Serianni, G.; De Muri, M.; Veltri, P.; Antoni, V.; Baltador, C.; Barbisan, M.; Brombin, M.; Galatá, A.; Ippolito, N.; Kulevoy, T.; Pasqualotto, R.; Petrenko, S.; Pimazzoni, A.; Recchia, M.; Sartori, E.; Taccogna, F.; Variale, V.; Zaniol, B.; Barbato, P.; Baseggio, L.; Cervaro, V.; Fasolo, D.; Franchin, L.; Ghiraldelli, R.; Laterza, B.; Maniero, M.; Martini, D.; Migliorato, L.; Minarello, A.; Molon, F.; Moro, G.; Patton, T.; Ravarotto, D.; Rizzieri, R.; Rizzolo, A.; Sattin, M.; Stivanello, F.; Zucchetti, S.

    2017-08-01

    The ion source NIO1 (Negative Ion Optimization 1) was developed and installed as a reduced-size model of multi-aperture sources used in neutral beam injectors. NIO1 beam optics is optimized for a 135 mA H- current (subdivided in 9 beamlets) at a Vs = 60 kV extraction voltage, with an electron-to-ion current ratio Rj up to 2. Depending on gas pressure used, NIO1 was up to now operated with Vs < 25 kV for beam extraction and Vs = 60 kV for insulation tests. The distinction between capacitively coupled plasma (E-mode, consistent with a low electron density plasma ne) and inductively coupled plasma (H-mode, requiring larger ne) was clearly related to several experimental signatures, and was confirmed for several gases, when applied radiofrequency power exceeds a given threshold Pt (with hysteresis). For hydrogen Pt was reduced below 1 kW, with a clean rf window and molybdenum liners on other walls; for oxygen Pt ≤ 400 W. Beams of H- and O- were separately extracted; since no caesium is yet introduced into the source, the expected ion currents are lower than 5 mA; this requires a lower acceleration voltage Vs (to keep the same perveance). NIO1 caesium oven was separately tested and Cs dispensers are in development. Increasing the current in the magnetic filter circuit, modifying its shape, and increasing the bias voltage were helpful to reduce Rj (still very large up to now, about 150 for oxygen, and 40 for hydrogen), in qualitative agreement with theoretical and numerical models. A second bias voltage was tested for hydrogen. Beam footprints and a spectral emission sample are shown.

  1. Kinetic energy offsets for multicharged ions from an electron beam ion source.

    Science.gov (United States)

    Kulkarni, D D; Ahl, C D; Shore, A M; Miller, A J; Harriss, J E; Sosolik, C E; Marler, J P

    2017-08-01

    Using a retarding field analyzer, we have measured offsets between the nominal and measured kinetic energy of multicharged ions extracted from an electron beam ion source (EBIS). By varying source parameters, a shift in ion kinetic energy was attributed to the trapping potential produced by the space charge of the electron beam within the EBIS. The space charge of the electron beam depends on its charge density, which in turn depends on the amount of negative charge (electron beam current) and its velocity (electron beam energy). The electron beam current and electron beam energy were both varied to obtain electron beams of varying space charge and these were related to the observed kinetic energy offsets for Ar(4+) and Ar(8+) ion beams. Knowledge of these offsets is important for studies that seek to utilize slow, i.e., low kinetic energy, multicharged ions to exploit their high potential energies for processes such as surface modification. In addition, we show that these offsets can be utilized to estimate the effective radius of the electron beam inside the trap.

  2. PIC modeling of negative ion sources for fusion

    Science.gov (United States)

    Taccogna, F.; Minelli, P.

    2017-01-01

    This work represents the first attempt to model the full-size ITER negative ion source prototype including expansion, extraction and part of the acceleration regions keeping the resolution fine enough to resolve every single aperture of the extraction grid. The model consists of a 2.5-dimensional Particle-in-Cell/Monte Carlo Collision representation of the plane perpendicular to the filter field lines. Both the magnetic filter and electron deflection fields have been included. A negative ion current density of {j}{H-}=500 {{A}} {{{m}}}-2 produced by neutral conversion from the plasma grid is used as fixed parameter, while negative ions produced by electron dissociative attachment of vibrationally excited molecules and by ionic conversion on plasma grid are self-consistently simulated. Results show the non-ambipolar character of the transport in the expansion region driven by electron magnetic drifts in the plane perpendicular to the filter field. It induces a top-bottom asymmetry detected up to the extraction grid which in turn leads to a tilted positive ion flow hitting the plasma grid and a tilted negative ion flow emitted from the plasma grid. As a consequence, the plasma structure is not uniform around the single aperture: the meniscus assumes a form of asymmetric lobe and a deeper potential well is detected from one side of the aperture relative to the other side. Therefore, the surface-produced contribution to the negative ion extraction is not equally distributed between both the sides around the aperture but it come mainly from the lower side of the grid giving an asymmetrical current distribution in the single beamlet.

  3. Ion source memory in {sup 36}Cl accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Merchel, Silke; Rugel, Georg [HZDR, Dresden (Germany); Arnold, Maurice; Aumaitre, Georges; Bourles, Didier; Martschini, Martin [ASTER, Aix-en-Provence (France); Buchriegler, Josef; Golser, Robin; Keddadouche, Karim; Steier, Peter [VERA, Vienna (Austria)

    2013-07-01

    Since the DREAMS (Dresden Accelerator Mass Spectrometry) facility went operational in 2011, constant effort was put into enabling routine measurements of long-lived radionuclides as {sup 10}Be, {sup 26}Al and {sup 41}Ca. For precise AMS-measurements of the volatile element Cl the key issue is the minimization of the long term memory effect. For this purpose one of the two original HVE sources was mechanically modified, allowing the usage of bigger cathodes with individual target apertures. Additionally a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, a small inter-laboratory comparison had been initiated. The long-term memory effect in the Cs sputter ion sources of the AMS facilities VERA, ASTER and DREAMS had been investigated by running samples of natural {sup 35}Cl/{sup 37}Cl-ratio and samples containing highly enriched {sup 35}Cl({sup 35}Cl/{sup 37}Cl > 500). Primary goals of the research are the time constants of the recovery from the contaminated sample ratio to the initial ratio of the sample and the level of the long-term memory effect in the sources.

  4. Advancement of highly charged ion beam production by superconducting ECR ion source SECRAL (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Sun, L., E-mail: sunlt@impcas.ac.cn; Lu, W.; Zhang, W. H.; Feng, Y. C.; Qian, C.; Ma, H. Y.; Zhang, X. Z.; Zhao, H. W. [Institute of Modern Physics, CAS, Lanzhou 730000 (China); Guo, J. W.; Yang, Y.; Fang, X. [Institute of Modern Physics, CAS, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2016-02-15

    At Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), the superconducting Electron Cyclotron Resonance (ECR) ion source SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) has been put into operation for about 10 years now. It has been the main working horse to deliver intense highly charged heavy ion beams for the accelerators. Since its first plasma at 18 GHz, R&D work towards more intense highly charged ion beam production as well as the beam quality investigation has never been stopped. When SECRAL was upgraded to its typical operation frequency 24 GHz, it had already showed its promising capacity of very intense highly charged ion beam production. And it has also provided the strong experimental support for the so called scaling laws of microwave frequency effect. However, compared to the microwave power heating efficiency at 18 GHz, 24 GHz microwave heating does not show the ω{sup 2} scale at the same power level, which indicates that microwave power coupling at gyrotron frequency needs better understanding. In this paper, after a review of the operation status of SECRAL with regard to the beam availability and stability, the recent study of the extracted ion beam transverse coupling issues will be discussed, and the test results of the both TE{sub 01} and HE{sub 11} modes will be presented. A general comparison of the performance working with the two injection modes will be given, and a preliminary analysis will be introduced. The latest results of the production of very intense highly charged ion beams, such as 1.42 emA Ar{sup 12+}, 0.92 emA Xe{sup 27+}, and so on, will be presented.

  5. Advancement of highly charged ion beam production by superconducting ECR ion source SECRAL (invited)

    Science.gov (United States)

    Sun, L.; Guo, J. W.; Lu, W.; Zhang, W. H.; Feng, Y. C.; Yang, Y.; Qian, C.; Fang, X.; Ma, H. Y.; Zhang, X. Z.; Zhao, H. W.

    2016-02-01

    At Institute of Modern Physics (IMP), Chinese Academy of Sciences (CAS), the superconducting Electron Cyclotron Resonance (ECR) ion source SECRAL (Superconducting ECR ion source with Advanced design in Lanzhou) has been put into operation for about 10 years now. It has been the main working horse to deliver intense highly charged heavy ion beams for the accelerators. Since its first plasma at 18 GHz, R&D work towards more intense highly charged ion beam production as well as the beam quality investigation has never been stopped. When SECRAL was upgraded to its typical operation frequency 24 GHz, it had already showed its promising capacity of very intense highly charged ion beam production. And it has also provided the strong experimental support for the so called scaling laws of microwave frequency effect. However, compared to the microwave power heating efficiency at 18 GHz, 24 GHz microwave heating does not show the ω2 scale at the same power level, which indicates that microwave power coupling at gyrotron frequency needs better understanding. In this paper, after a review of the operation status of SECRAL with regard to the beam availability and stability, the recent study of the extracted ion beam transverse coupling issues will be discussed, and the test results of the both TE01 and HE11 modes will be presented. A general comparison of the performance working with the two injection modes will be given, and a preliminary analysis will be introduced. The latest results of the production of very intense highly charged ion beams, such as 1.42 emA Ar12+, 0.92 emA Xe27+, and so on, will be presented.

  6. Size scaling of negative hydrogen ion sources for fusion

    Science.gov (United States)

    Fantz, U.; Franzen, P.; Kraus, W.; Schiesko, L.; Wimmer, C.; Wünderlich, D.

    2015-04-01

    The RF-driven negative hydrogen ion source (H-, D-) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.

  7. 6.4 GHz ECR ion source at VECC

    Indian Academy of Sciences (India)

    G S Taki; D K Chakraborty; R K Bhandari

    2002-11-01

    The 6.4 GHz ECR ion source that was indigenously developed a few years ago has been operating continuously for injecting oxygen and neon beams to the cyclotron since 1997. VEC-ECR is a single stage high magnetic field ion source provided with a negatively biased electron repeller placed on the axis, near the injection mirror point. The supply of cold electrons and use of low mass mixing gas improve the stability of ECR plasma. Very recently, the effect of aluminum oxide coating on the copper plasma chamber wall has been studied. The plasma chamber wall was coated with aluminum by vacuum evaporation method and then exposed to oxygen gas to form aluminum oxide. It was noticed that the process substantially shifts the charge state distribution to the higher charge state with an enhancement of ion current by an order of magnitude. With the aluminized plasma chamber, the VEC-ECR can now produce 12 A of O7+, 6.5 A of Ar12+, 1.5 A of Kr20+ and 1.0 A of Xe31+.

  8. Plasmas in compact traps: From ion sources to multidisciplinary research

    Science.gov (United States)

    Mascali, D.; Musumarra, A.; Leone, F.; Galatà, A.; Romano, F. P.; Gammino, S.

    2017-09-01

    In linear (minimum-B) magneto-static traps dense and hot plasmas are heated by electromagnetic radiation in the GHz domain via the Electron Cyclotron Resonance (ECR). The values of plasma density, temperature and confinement times ( n_eτ_i>10^{13} cm ^{-3} s; T_e>10 keV) are similar to the ones of thermonuclear plasmas. The research in this field -devoted to heating and confinement optimization- has been supported by numerical modeling and advanced diagnostics, for probing the plasma especially in a non-invasive way. ECR-based systems are nowadays able to produce extremely intense (tens or hundreds of mA) beams of light ions (p, d, He), and relevant currents of heavier elements (C, O, N) up to heavy ions like Xe, Pb, U. Such beams can be extracted from the trap by a proper electrostatic system. The above-mentioned properties make these plasmas very attractive for interdisciplinary researches also, such as i) nuclear decays rates measurements in stellar-like conditions, ii) energy conversion studies, being exceptional sources of short-wavelength electromagnetic radiation (EUV, X-rays, hard X-rays and gammas, useful in material science and archaeometry), iii) environments allowing precise spectroscopical measurements as benchmarks for magnetized astrophysical plasmas. The talk will give an overview about the state-of-the-art in the field of intense ion sources, and some new perspectives for interdisciplinary research, with a special attention to the developments based at INFN-LNS.

  9. A large-area RF source for negative hydrogen ions

    Science.gov (United States)

    Frank, P.; Feist, J. H.; Kraus, W.; Speth, E.; Heinemann, B.; Probst, F.; Trainham, R.; Jacquot, C.

    1998-08-01

    In a collaboration with CEA Cadarache, IPP is presently developing an rf source, in which the production of negative ions (H-/D-) is being investigated. It utilizes PINI-size rf sources with an external antenna and for the first step a small size extraction system with 48 cm2 net extraction area. First results from BATMAN (Ba¯varian T_est Ma¯chine for N_egative Ions) show (without Cs) a linear dependence of the negative ion yield with rf power, without any sign of saturation. At elevated pressure (1.6 Pa) a current density of 4.5 mA/cm2 H- (without Cs) has been found so far. At medium pressure (0.6 Pa) the current density is lower by approx. a factor of 5, but preliminary results with Cesium injection show a relative increase by almost the same factor in this pressure range. Langmuir probe measurements indicate an electron temperature Te>2 eV close to the plasma grid with a moderate magnetic filter (700 Gcm). Attempts to improve the performance by using different magnetic configurations and different wall materials are under way.

  10. Miniaturized Sources and Traps for Spectroscopy of Multicharged Ions

    Science.gov (United States)

    Tan, Joseph; Guise, Nicholas

    2013-05-01

    Penning traps made extremely compact (earth (NdFeB) magnets have been used recently to isolate highly charged ions (HCI) for spectroscopy. For example, radiative lifetimes of metastable states are measured by observing the visible fluorescence emitted by isolated Ar XIV (441 nm, 2p 2P3/2 --> 2p 2P1/2) and Kr XVIII (637 nm, 3d 2D3/2 --> 3d 2D1/2) . These measurements use HCIs extracted from an electron beam ion trap (EBIT) at NIST. For planned experiments, a new apparatus is being developed which will incorporate a ``mini-EBIT'' source using similar permanent-magnet structures. It combines a mini-EBIT and a compact Penning trap to facilitate production of multicharged ions including bare nuclei with nuclear charge in the range Z =1 to Z =10, in a cryogen-free setup with multiple ports for laser and atomic beam access to the isolated HCI. One goal is to produce one-electron ions in Rydberg states with transitions accessible to an optical frequency comb. Such engineered atomic systems are sought to enable tests of theory that could illuminate the proton radius puzzle. J.N. Tan, S.M. Brewer, and N.D. Guise, Rev. Sci. Instrum. 83, 023103 (2012).

  11. Low-energy dc ion source for low operating pressure

    Energy Technology Data Exchange (ETDEWEB)

    Oks, Efim, E-mail: oks@opee.hcei.tsc.ru [Institute of High Current Electronics, Russian Academy of Sciences, Akademichesky ave. 2/3, Tomsk 634055 (Russian Federation); State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Shandrikov, Maxim [Institute of High Current Electronics, Russian Academy of Sciences, Akademichesky ave. 2/3, Tomsk 634055 (Russian Federation); Salvadori, Cecilia [Institute of Physics, University of São Paulo, C.P. 66318, CEP 05315-970 São Paulo S.P. (Brazil); Brown, Ian [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2014-08-15

    We report on an experimental study of an ion source based on a Penning discharge with a cold hollow cathode in crossed electric and magnetic fields. The minimum vacuum chamber operating pressure was 3 × 10{sup −5} Torr for argon and 5 × 10{sup −5} Torr for hydrogen. The use of a hollow cathode allowed decreasing the discharge operating voltage down to 350 V at a discharge current of ∼100 mA. At a discharge current of 100 mA and beam accelerating voltage of 2 kV, the ion current was 2.5 mA for argon and 8 mA for hydrogen, and the ion beam on-axis current density 170 and 450 μA/cm{sup 2}, respectively. The current-voltage characteristics of the discharge and the radial ion beam current density distribution were measured. The influence of pressure on the discharge parameters and their time stability was investigated.

  12. Optimization of a hot-cavity type resonant ionization laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Henares, J. L., E-mail: henares@ganil.fr; Lecesne, N.; Hijazi, L.; Bastin, B.; Leroy, R.; Osmond, B.; Vignet, J. L. [GANIL, BP 55027, 14076 Caen Cedex 5 (France); Kron, T.; Naubereit, P.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Staudinger Weg 7, 55099 Mainz (Germany); Lassen, J. [TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia V6T 2A3 (Canada); Le Blanc, F. [IPN Orsay, BP 1-91406 Orsay (France)

    2016-02-15

    Resonant Ionization Laser Ion Source (RILIS) is nowadays an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability and ability to ionize efficiently and element selectively. Grand Accélérateur National d’Ions Lourds (GANIL) Ion Source using Electron Laser Excitation (GISELE) is an off-line test bench for RILIS developed to study a fully operational resonant laser ion source at GANIL facility. The ion source body has been designed as a modular system to investigate different experimental approaches by varying the design parameters, to develop the future on-line laser ion source. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results concerning emittance and time profile development as a function of the temperature for different ion source versions will be presented.

  13. Production of rare-earth atomic negative ion beams in a cesium-sputter-type negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Davis, V.T. [Test Support Division, Defense Threat Reduction Agency, West Desert Test Center, Dugway, UT 84022-5000 (United States)]. E-mail: vernon.davis@us.army.mil; Covington, A.M. [Department of Physics, University of Nevada, MS 220, Reno, NV 89557-0058 (United States); Duvvuri, S.S. [Department of Physics, University of Nevada, MS 220, Reno, NV 89557-0058 (United States); Kraus, R.G. [Department of Physics, University of Nevada, MS 220, Reno, NV 89557-0058 (United States); Emmons, E.D. [Department of Physics, University of Nevada, MS 220, Reno, NV 89557-0058 (United States); Kvale, T.J. [Department of Physics and Astronomy, University of Toledo, Toledo, OH (United States); Thompson, J.S. [Department of Physics, University of Nevada, MS 220, Reno, NV 89557-0058 (United States)

    2007-08-15

    The desire to study negative ion structure and negative ion-photon interactions has spurred the development of ion sources for use in research and industry. The many different types of negative ion sources available today differ in their characteristics and abilities to produce anions of various species. Thus the importance of choosing the correct type of negative ion source for a particular research or industrial application is clear. In this study, the results of an investigation on the production of beams composed of negatively-charged rare-earth ions from a cylindrical-cathode-geometry, cesium-sputter-type negative ion source are presented. Beams of atomic anions have been observed for most of the first-row rare-earth elements, with typical currents ranging from hundreds of picoamps to several nanoamps.

  14. Dual arc penning ion source gas flow experiments

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, E.D.; Lord, R.S.; Mallory, M.L.; Antaya, T.A.

    1984-01-01

    Support gas, when added directly to an arc or admitted to an auxiliary chamber of a two-arc chamber ion source, increases the beam intensity for multicharged ions such as /sup 16/O/sup 5 +/. To clarify the mechanism of this intensity increase, gas flow rates from the auxiliary chamber to the main chamber have been measured by using the ORIC cyclotron as a mass spectrometer. The results show that only about three percent of the gas admitted to the auxiliary chamber reaches the main chamber. One can then infer that the improved operation probably results from the stabilizing effect of heating the common cathodes with the auxiliary arc and/or the more favorable distribution of the support gas to the part of the main arc close to the cathodes.

  15. New progress of high current gasdynamic ion source (invited)

    Science.gov (United States)

    Skalyga, V.; Izotov, I.; Golubev, S.; Sidorov, A.; Razin, S.; Vodopyanov, A.; Tarvainen, O.; Koivisto, H.; Kalvas, T.

    2016-02-01

    The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 1013 cm-3) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10-4-10-3 mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ṡ mm ṡ mrad have been demonstrated in recent experiments.

  16. New progress of high current gasdynamic ion source (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Skalyga, V., E-mail: skalyga@ipfran.ru; Sidorov, A.; Vodopyanov, A. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation); Izotov, I.; Golubev, S.; Razin, S. [Institute of Applied Physics, Russian Academy of Sciences (IAP RAS), 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation); Tarvainen, O.; Koivisto, H.; Kalvas, T. [Department of Physics, University of Jyvaskyla, P.O. Box 35 (YFL), 40500 Jyvaskyla (Finland)

    2016-02-15

    The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)—the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10{sup 13} cm{sup −3}) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10{sup −4}–10{sup −3} mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

  17. Performance of the ECR ion source of CERN's heavy ion injector

    CERN Document Server

    Bougarel, M P; Haseroth, H; Langbein, K; Tanke, E

    1995-01-01

    In fall 1994 the new heavy ion injector at CERN was brought into operation successfully and a lead beam of 2.9´107 ions per pulse was accelerated in the SPS up to an energy of 157 GeV/u. The ion source, which was supplied by GANIL (France) was in operation almost continuously over a period of about one year and proved to be very reliable. It pro-duces a current of more than 100 µA of Pb27+ (after the first spectrometer) during the afterglow of the pulsed discharge. The current stays within 5% of the maximum value for a time of about 1 ms, which is more than required by the accel-erators. Measurements of the charge state distribution, emittance and energy spread, which were made during this window, are presented together with other operating data.

  18. Next Generation H- Ion Sources for the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Welton, Robert F [ORNL; Carmichael, Justin R [ORNL; Carr, Jr, Jerry [ORNL; Crisp, Danny W [ORNL; Goulding, Richard Howell [ORNL; Han, Baoxi [ORNL; Pennisi, Terry R [ORNL; Murray Jr, S N [ORNL; Stockli, Martin P [ORNL; Tarvainen, Olli A [ORNL; Santana, Manuel [ORNL

    2009-01-01

    The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

  19. Computer simulations for rf design of a Spallation Neutron Source external antenna H ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung-Woo [ORNL; Goulding, Richard Howell [ORNL; Kang, Yoon W [ORNL; Shin, Ki [ORNL; Welton, Robert F [ORNL

    2010-01-01

    Electromagnetic modeling of the multicusp external antenna H ion source for the Spallation Neutron Source SNS has been performed in order to optimize high-power performance. During development of the SNS external antenna ion source, antenna failures due to high voltage and multicusp magnet holder rf heating concerns under stressful operating conditions led to rf characteristics analysis. In rf simulations, the plasma was modeled as an equivalent lossy metal by defining conductivity as . Insulation designs along with material selections such as ferrite and Teflon could be included in the computer simulations to compare antenna gap potentials, surface power dissipations, and input impedance at the operating frequencies, 2 and 13.56 MHz. Further modeling and design improvements are outlined in the conclusion.

  20. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul; Dudnikov, Vadim

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  1. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  2. Conceptional design of the laser ion source based hadrontherapy facility

    Science.gov (United States)

    Xie, Xiu-Cui; Song, Ming-Tao; Zhang, Xiao-Hu

    2014-04-01

    A laser ion source (LIS), which can provide a carbon beam with highly stripped state (C6+) and high intensity (several tens mA), would significantly change the overall design of the hadrontherapy facility. The proposed LIS based hadrontherapy facility has the advantages of short linac length, simple injection scheme, and small synchrotron size. With the experience from the DPIS and HITFiL projects that have been conducted in IMP, a conceptional design of the LIS based hadrontherapy facility will be presented, with special attention given to APF type IH DTL design and simulation.

  3. Conceptional Design of the Laser Ion Source based Hadrontherapy Facility

    CERN Document Server

    Xie, Xiucui; Zhang, Xiaohu

    2013-01-01

    Laser ion source (LIS), which can provide carbon beam with highly stripped state (C6+) and high intensity (several tens mA), would significantly change the overall design of the hadrontherapy facility. A LIS based hadrontherapy facility is proposed with the advantage of short linac length, simple injection scheme and small synchrotron size. With the experience from the DPIS and HITFiL project that had conducted in IMP, a conceptional design of the LIS based hadrontherapy facility will be present with special dedication to APF type IH DTL design and simulation.

  4. Effect of dietary copper amount and source on copper metabolism and oxidative stress of weanling pigs in short-term feeding.

    Science.gov (United States)

    Huang, Y L; Ashwell, M S; Fry, R S; Lloyd, K E; Flowers, W L; Spears, J W

    2015-06-01

    Forty-eight weanling barrows were used to determine the effects of amount and source of dietary Cu on Cu metabolism, oxidative stress in the duodenum, and VFA ratios in the cecum of weanling pigs in short-term feeding. At 21 d of age, newly weaned pigs were stratified by BW (7.03 ± 1.20 kg) and equally assigned to 1 of the following dietary treatments: 1) control (5 mg supplemental Cu/kg diet from CuSO4), 2) 225 mg supplemental Cu/kg diet from CuSO4, or 3) 225 mg supplemental Cu/kg diet from tribasic Cu chloride (TBCC). Pigs were housed 2 pigs per pen and were fed a complex diet until harvest on d 11 and 12. During harvest, bile and liver were obtained for mineral analysis, and liver samples were obtained for analysis of mRNA expression of Cu regulatory proteins. Digesta of duodenum, proximal jejunum, and ileum were collected for soluble Cu analysis. Mucosal scrapings of duodenum, proximal jejunum, and ileum were obtained for analysis of mucosal Cu concentration and mRNA expression of Cu regulatory proteins. Duodenal mucosal scrapings were also collected for analysis of malondialdehyde (MDA). Pigs fed high Cu had markedly greater (P pigs. Duodenal MDA concentrations were greater (P = 0.003) in CuSO4 vs. control pigs and tended (P = 0.06) to be greater than in TBCC pigs. Duodenal antioxidant 1 (Atox1) mRNA was downregulated (P pigs fed high Cu compared to controls and was not affected by Cu source. Compared with control pigs, those fed CuSO4 and TBCC had greater (P pigs. Hepatic Cu transporting β-polypeptide ATPase (Atp7b) was upregulated (P = 0.02) in the Cu-supplemented pigs compared with controls and did not differ among Cu sources. The acetate:propionate ratio in cecal contents was much greater in pigs supplemented with 225 mg Cu/kg diet than in controls. When fed at 225 mg Cu/kg diet, TBCC may cause less oxidative stress in the duodenum than CuSO4. Feeding weanling pigs increased Cu resulted in modulation of duodenal and liver at the transcription level.

  5. Negative ion production and beam extraction processes in a large ion source (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Tsumori, K., E-mail: tsumori@nifs.ac.jp; Nakano, H.; Goto, M.; Nagaoka, K.; Osakabe, M.; Takeiri, Y.; Kaneko, O. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); The Graduate University for Advanced Studies, Shonan Village, Hayama, Kanagawa 240-0193 (Japan); Ikeda, K.; Kisaki, M. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Geng, S. [The Graduate University for Advanced Studies, Shonan Village, Hayama, Kanagawa 240-0193 (Japan); Wada, M. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan); Sasaki, K.; Nishiyama, S. [Division of Quantum Science and Engineering, Hokkaido University, Sapporo 060-8628 (Japan); Serianni, G.; Agostinetti, P.; Sartori, E.; Brombin, M.; Veltri, P. [Plasma Engineering Group, Consorzio RFX, Corso Stati Uniti 4, 35127 Padova (Italy); Wimmer, C. [Max-Planck-Institut für Plasmaphysik, Bereich ITER-Technologie und -Diagnostik/N-NBI Boltzmannstr. 2, 85748 Garching (Germany)

    2016-02-15

    Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H{sup −}) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H{sup −} density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H{sub 2} plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

  6. Ion Extraction from a Toroidal Electron Cyclotron Resonance Ion Source: a Numerical Feasibility Study

    Science.gov (United States)

    Caliri, Claudia; Volpe, Francesco; Gammino, Santo; Mascali, David

    2013-10-01

    Electron Cyclotron Resonance Ion Sources (ECRIS) are magnetic mirror plasmas of microwave-heated electrons and cold multi-charged ions. The ions are extracted from one end of the mirror and injected in accelerators for nuclear and particle physics studies, hadrontherapy, or neutral beam injection in fusion plasmas. ECRIS devices progressed to higher and higher ion currents and charge states by adopting stronger magnetic fields (beneficial for confinement) and proportionally higher ECR frequencies. Further improvements would require the attainment of ``triple products'' comparable with major fusion experiments. For this, we propose a new, toroidal rather than linear, ECRIS geometry, which would at the same time improve confinement and make better use of the magnetic field. Ion extraction is more complicated than from a linear device, but feasible, as our modeling indicates. Possible techniques involve charge-dependent drifts, divertors, specially designed magnetic fields and associated loss-cones, electrostatic and/or magnetic deflectors, or techniques used in accelerators to transfer particles from one storage ring or accelerator to the next. Here we present single-particle tracings assessing and comparing these extraction techniques.

  7. Ion source development for the Los Alamos heavy ion fusion injector

    Energy Technology Data Exchange (ETDEWEB)

    Rutkowski, H.L.; Engelhardt, L.S.; Humphries, S.; Meyer, E.A.; Oona, H.; Shurter, R.P.

    1985-10-01

    A multi-beam injector is being designed and built at Los Alamos for the U.S. Heavy Ion Fusion Program. As part of this program, development of an aluminum-spark, pulsed plasma source is being carried out. Faraday cup diagnostics are used to study current emission and to map the current profile. An aluminum oxide scintillator with photographic film is used in conjunction with a pepper-pot to obtain time integrated emittance values.

  8. Ion source development for the Los Alamos heavy ion fusion injector

    Energy Technology Data Exchange (ETDEWEB)

    Rutkowski, H.L.; Oona, H.; Meyer, E.A.; Shurter, R.P.; Engelhardt, L.S.; Humphries, S. Jr.

    1985-01-01

    A multi-beam injector is being designed and built at Los Alamos for the US Heavy Ion Fusion Program. As part of this program, development of an aluminum-spark, pulsed plasma source is being carried out. Faraday cup diagnostics are used to study current emission and to map the current profile. An aluminum oxide scintillator with photographic film is used in conjunction with a pepper-pot to obtain time integrated emittance values.

  9. Dietary energy source largely affects tissue fatty acid composition but has minor influence on gene transcription in Iberian pigs.

    Science.gov (United States)

    Óvilo, C; Benítez, R; Fernández, A; Isabel, B; Núñez, Y; Fernández, A I; Rodríguez, C; Daza, A; Silió, L; López-Bote, C

    2014-03-01

    A trial was performed to compare the effects of different dietary sources of MUFA on the fatty acid (FA) composition, lipid metabolism, and gene transcription in different tissues of Iberian pigs. Twenty-seven Iberian male pigs of 28 kg live weight (LW) were divided in 2 groups and fed with 1 of 2 isocaloric diets: a standard diet with carbohydrates as energy source (CH) and a diet enriched with high-oleic sunflower oil (HO). Ham adipose tissue was sampled by biopsy at 44 and 70 kg LW. At 110 kg LW pigs were slaughtered and backfat, loin, and liver tissues were sampled. Animals of the HO group showed higher MUFA content and lower SFA in all the analyzed tissues (P dietary groups (PP < 0.01), 37 genes were considered differentially expressed (DE). Gene ontology allowed relating them with several biological functions including lipid metabolic processes. Quantitative PCR confirmed several DE genes in adipose tissue (RXRG, LEP, and ME1; P < 0.0001, P < 0.05, and P < 0.0001, respectively), but no DE gene was found in loin or liver tissues. Joint results agree with a metabolic adjustment of adipose tissue FA levels by the subtle effect of the diet on the regulation of several lipid metabolism pathways, mainly FA oxidation and prostanoid synthesis, with LEP, RXRG, and PTGS2 genes playing mayor roles.

  10. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept

    NARCIS (Netherlands)

    Melin, G.; Drentje, A. G.; Girard, A.; Hitz, D.

    1999-01-01

    Abstract: An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An express

  11. An assessment of soybeans and other vegetable proteins as source of salmonella contamination in pig production

    Directory of Open Access Journals (Sweden)

    Häggblom Per

    2010-02-01

    Full Text Available Abstract Background The impact of salmonella contaminated feed ingredients on the risk for spreading salmonella to pigs was assessed in response to two incidences when salmonella was spread by feed from two feed mills to 78 swine producing herds. Methods The assessment was based on results from the salmonella surveillance of feed ingredients before introduction to feed mills and from HACCP - based surveillance of the feed mills. Results from the mills of the Company (A that produced the salmonella contaminated feed, were by the Chi. Square test compared to the results from all the other (B - E feed producers registered in Sweden. Isolated serovars were compared to serovars from human cases of salmonellosis. Results Salmonella (28 serovars was frequently isolated from imported consignments of soybean meal (14.6% and rape seed meal (10.0%. Company A largely imported soybean meal from crushing plants with a history of unknown or frequent salmonella contamination. The risk for consignments of vegetable proteins to be salmonella contaminated was 2.4 times (P Conclusions Salmonella contaminated feed ingredients are an important source for introducing salmonella into the feed and food chain. Effective HACCP-based control and associated corrective actions are required to prevent salmonella contamination of feed. Efforts should be taken to prevent salmonella contamination already at the crushing plants. This is challenge for the EU - feed industry due to the fact that 98% of the use of soybean/meal, an essential feed ingredient, is imported from crushing plants of third countries usually with an unknown salmonella status.

  12. Sewage sludge and liquid pig manure as possible sources of antibiotic resistant bacteria.

    Science.gov (United States)

    Hölzel, Christina S; Schwaiger, Karin; Harms, Katrin; Küchenhoff, Helmut; Kunz, Anne; Meyer, Karsten; Müller, Christa; Bauer, Johann

    2010-05-01

    Within the last decades, the environmental spread of antibiotic resistant bacteria has become a topic of concern. In this study, liquid pig manure (n=305) and sewage sludge (n=111) - used as agricultural fertilizers between 2002 and 2005 - were investigated for the presence of Escherichia coli, Enterococcus faecalis and Enterococcus faecium. Bacteria were tested for their resistance against 40 chemotherapeutics including several "reserve drugs". E. coli (n=613) from pig manure were at a significantly higher degree resistant to streptomycin, doxycycline, spectinomycin, cotrimoxazole, and chloramphenicol than E. coli (n=116) from sewage sludge. Enterococci (Ent. faecalis, n=387, and Ent. faecium, n=183) from pig manure were significantly more often resistant to high levels of doxycycline, rifampicin, erythromycin, and streptomycin than Ent. faecalis (n=44) and Ent. faecium (n=125) from sewage sludge. Significant differences in enterococcal resistance were also seen for tylosin, chloramphenicol, gentamicin high level, fosfomycin, clindamicin, enrofloxacin, moxifloxacin, nitrofurantoin, and quinupristin/dalfopristin. By contrast, aminopenicillins were more effective in enterococci from pig manure, and mean MIC-values of piperacillin+tazobactam and third generation cefalosporines were significantly lower in E. coli from pig manure than in E. coli from sewage sludge. 13.4% (E. coli) to 25.3% (Ent. faecium) of pig manure isolates were high-level multiresistant to substances from more than three different classes of antimicrobial agents. In sewage sludge, high-level-multiresistance reached from 0% (Ent. faecalis) to 16% (Ent. faecium). High rates of (multi-) resistant bacteria in pig manure emphasize the need for a prudent - cautious - use of antibiotics in farm animals.

  13. Charge breeding results and future prospects with electron cyclotron resonance ion source and electron beam ion source (invited).

    Science.gov (United States)

    Vondrasek, R; Levand, A; Pardo, R; Savard, G; Scott, R

    2012-02-01

    The Californium Rare Ion Breeder Upgrade (CARIBU) of the Argonne National Laboratory ATLAS facility will provide low-energy and reaccelerated neutron-rich radioactive beams for the nuclear physics program. A 70 mCi (252)Cf source produces fission fragments which are thermalized and collected by a helium gas catcher into a low-energy particle beam with a charge of 1+ or 2+. An electron cyclotron resonance (ECR) ion source functions as a charge breeder in order to raise the ion charge sufficiently for acceleration in the ATLAS linac. The final CARIBU configuration will utilize a 1 Ci (252)Cf source to produce radioactive beams with intensities up to 10(6) ions∕s for use in the ATLAS facility. The ECR charge breeder has been tested with stable beam injection and has achieved charge breeding efficiencies of 3.6% for (23)Na(8+), 15.6% for (84)Kr(17+), and 13.7% for (85)Rb(19+) with typical breeding times of 10 ms∕charge state. For the first radioactive beams, a charge breeding efficiency of 11.7% has been achieved for (143)Cs(27+) and 14.7% for (143)Ba(27+). The project has been commissioned with a radioactive beam of (143)Ba(27+) accelerated to 6.1 MeV∕u. In order to take advantage of its lower residual contamination, an EBIS charge breeder will replace the ECR charge breeder in the next two years. The advantages and disadvantages of the two techniques are compared taking into account the requirements of the next generation radioactive beam facilities.

  14. A comparison of the plasma characteristics of two multicusp negative ion sources

    Science.gov (United States)

    Graham, W. G.; Steen, P. G.; Courteille, C.; Leroy, R.; Bacal, M.

    1996-07-01

    Electron temperature, electron density and negative ion fraction measurements in two different multicusp negative hydrogen ion sources, operating under similar conditions one at Queen's University and one at Ecole Polytechnique, are compared. Some data from a third source at FOM are also included in the comparisons. The agreement between electron temperature and density measurements is generally good. There are however considerable discrepancies between the negative ion fraction measurements. This illustrates the great sensitivity of negative ion fractions to the exact source conditions.

  15. Angular resolved energy analysis of /sup 69/Ga/sup +/ions from a gallium liquid metal ion source

    Energy Technology Data Exchange (ETDEWEB)

    Marriott, P.

    1987-11-01

    An analysis system has been designed and built to characterise liquid metal ion source beams. Both mass and angular resolved energy distribution measurements can be made, from which both FWHM energy spreads and energy deficits can be obtained. This paper briefly describes the system and presents and discusses the first off-axis results taken with a gallium liquid metal ion source.

  16. Development of a compact electron-cyclotron-resonance ion source for high-energy carbon-ion therapy

    NARCIS (Netherlands)

    Muramatsu, M; Kitagawa, A; Sakamoto, Y; Sato, S; Sato, Y; Ogawa, H; Yamada, S; Ogawa, H; Yoshida, Y; Drentje, AG

    2005-01-01

    Ion sources for medical facilities should have characteristics of easy maintenance, low electric power consumption, good stability, and long operation time without problems (one year or longer). For this, a 10 GHz compact electron-cyclotron-resonance ion source with all-permanent magnets (Kei2

  17. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H. Y., E-mail: zhaohy@impcas.ac.cn; Zhang, J. J.; Jin, Q. Y.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Liu, W.; Wang, G. C. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2016-02-15

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10{sup 13} W cm{sup −2} in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  18. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited)

    Science.gov (United States)

    Zhao, H. Y.; Zhang, J. J.; Jin, Q. Y.; Liu, W.; Wang, G. C.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 1013 W cm-2 in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  19. New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited).

    Science.gov (United States)

    Zhao, H Y; Zhang, J J; Jin, Q Y; Liu, W; Wang, G C; Sun, L T; Zhang, X Z; Zhao, H W

    2016-02-01

    A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10(13) W cm(-2) in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

  20. Magnetic field design for a Penning ion source for a 200 keV electrostatic accelerator

    Science.gov (United States)

    Fathi, A.; Feghhi, S. A. H.; Sadati, S. M.; Ebrahimibasabi, E.

    2017-04-01

    In this study, the structure of magnetic field for a Penning ion source has been designed and constructed with the use of permanent magnets. The ion source has been designed and constructed for a 200 keV electrostatic accelerator. With using CST Studio Suite, the magnetic field profile inside the ion source was simulated and an appropriate magnetic system was designed to improve particle confinement. Designed system consists of two ring magnets with 9 mm distance from each other around the anode. The ion source was constructed and the cylindrical magnet and designed magnetic system were tested on the ion source. The results showed that the ignition voltage for ion source with the designed magnetic system is almost 300 V lower than the ion source with the cylindrical magnet. Better particle confinement causes lower voltage discharge to occur.

  1. Overdense plasma generation in a compact ion source

    Science.gov (United States)

    Castro, G.; Mascali, D.; Gammino, S.; Torrisi, G.; Romano, F. P.; Celona, L.; Altana, C.; Caliri, C.; Gambino, N.; Lanaia, D.; Miracoli, R.; Neri, L.; Sorbello, G.

    2017-05-01

    Electron cyclotron resonance ion sources (ECRIS) are widely used plasma based machines for the production of intense ion beams in science and industry. The performance of modern devices is limited by the presence of the density cut-off, above which electromagnetic (EM) waves sustaining the plasma are reflected. We hereby discuss the systematic data analysis of electrostatic wave generation in an ECR prototype operating at 3.75 GHz-0.1 THz. In particular, electron Bernstein waves (EBW) have been excited. EBW have already been generated in large-scale plasma devices for thermonuclear fusion purposes. In ion sources where L c ˜ λ RF (L c being the plasma chamber size and λ RF the pumping wave wavelength) the EM field assumes a modal behaviour; thus both plasma and EM field self-organize so that no optical-like wave launching is possible (i.e. the cavity effect dominates on the optical path). The collected data, however, supported by 3D full-wave simulations, actually demonstrate that a Budden-type X-B conversion scenario can be established above some critical RF power thresholds, operating in an off-ECR regime. The generation and absorption of the EBW has been demonstrated by the presence of three peculiar signatures: along with the establishment of an overdense plasma, generation of supra-thermal electrons and modification (non-linear broadening) of the EM spectrum measured within the plasma have been observed. At the threshold establishing such a heating regime, the collected data provide evidence for a fast rotation of the electron fluid.

  2. Pulsed ion sheath dynamics in a cylindrical bore for inner surface grid-enhanced plasma source ion implantation

    CERN Document Server

    Wang Jiu Li; Fan Song Hua; Yang Wu Bao; Yang Size

    2002-01-01

    Based on authors' recently proposed grid-enhanced plasma source ion implantation (GEPSII) technique for inner surface modification of materials with cylindrical geometry, the authors present the corresponding theoretical studies of the temporal evolution of the plasma ion sheath between the grid electrode and the target in a cylindrical bore. Typical results such as the ion sheath evolution, time-dependent ion density and time-integrated ion energy distribution at the target are calculated by solving Poisson's equation coupled with fluid equations for collisionless ions and Boltzmann assumption for electrons using finite difference methods. The calculated results can further verify the feasibility and superiority of this new technique

  3. Comparison of different antenna designs in the spallation neutron source negative hydrogen ion source

    Science.gov (United States)

    Veitzer, Seth A.; Kundrapu, Madhusudhan; Stoltz, Peter H.; Beckwith, Kristian R. C.

    2017-08-01

    Internal antenna negative hydrogen ion sources can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. During this process, plasma ions impacting the surfaces of rf antennas causes heating of the coating, which can melt or ablate, thus exposing conducting surfaces to the plasma. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator has been one of the top priorities of the SNS H-Source Program at ORNL. We have been utilizing numerical modeling of internal antenna negative hydrogen ion sources in order help optimize antenna designs in order to reduce antenna failures. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS internal antenna negative ion source. We report here on results comparing two different antenna designs. The baseline design, as is currently in use in the SNS source, and a wide-leg design, that has been tested, and may replace the baseline design if it can reduce antenna failures while still maintaining source performance. The wide-leg antenna is designed to move the antenna supports out of the high-density plasma regions, in order to decrease the possible negative effects of ion bombardment. We model the plasma evolution using a single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field for both the baseline and wide-leg antenna configurations. We find that the maximum plasma velocity near the antenna surfaces is reduced by nearly 50% in the wide-leg configuration, and that overall the bulk plasma velocity is reduced for this configuration. In addition, although we measure a small increase in the maximum plasma flux on the antenna surface for the wide-leg design, we see a broad-based reduction of plasma flux on the antenna in the regions where the antenna is mostly exposed to the

  4. Size scaling of negative hydrogen ion sources for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Fantz, U., E-mail: ursel.fantz@ipp.mpg.de; Franzen, P.; Kraus, W.; Schiesko, L.; Wimmer, C.; Wünderlich, D. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-04-08

    The RF-driven negative hydrogen ion source (H{sup −}, D{sup −}) for the international fusion experiment ITER has a width of 0.9 m and a height of 1.9 m and is based on a ⅛ scale prototype source being in operation at the IPP test facilities BATMAN and MANITU for many years. Among the challenges to meet the required parameters in a caesiated source at a source pressure of 0.3 Pa or less is the challenge in size scaling of a factor of eight. As an intermediate step a ½ scale ITER source went into operation at the IPP test facility ELISE with the first plasma in February 2013. The experience and results gained so far at ELISE allowed a size scaling study from the prototype source towards the ITER relevant size at ELISE, in which operational issues, physical aspects and the source performance is addressed, highlighting differences as well as similarities. The most ITER relevant results are: low pressure operation down to 0.2 Pa is possible without problems; the magnetic filter field created by a current in the plasma grid is sufficient to reduce the electron temperature below the target value of 1 eV and to reduce together with the bias applied between the differently shaped bias plate and the plasma grid the amount of co-extracted electrons. An asymmetry of the co-extracted electron currents in the two grid segments is measured, varying strongly with filter field and bias. Contrary to the prototype source, a dedicated plasma drift in vertical direction is not observed. As in the prototype source, the performance in deuterium is limited by the amount of co-extracted electrons in short as well as in long pulse operation. Caesium conditioning is much harder in deuterium than in hydrogen for which fast and reproducible conditioning is achieved. First estimates reveal a caesium consumption comparable to the one in the prototype source despite the large size.

  5. Ion Bernstein instability as a possible source for oxygen ion cyclotron harmonic waves

    Science.gov (United States)

    Min, Kyungguk; Denton, Richard E.; Liu, Kaijun; Gary, S. Peter; Spence, Harlan E.

    2017-05-01

    This paper demonstrates that an ion Bernstein instability can be a possible source for recently reported electromagnetic waves with frequencies at or near the singly ionized oxygen ion cyclotron frequency, ΩO+, and its harmonics. The particle measurements during strong wave activity revealed a relatively high concentration of oxygen ions (˜15%) whose phase space density exhibits a local peak at energy ˜20 keV. Given that the electron plasma-to-cyclotron frequency ratio is ωpe/Ωe≳1, this energy corresponds to the particle speed v/vA≳0.3, where vA is the oxygen Alfvén speed. Using the observational key plasma parameters, a simplified ion velocity distribution is constructed, where the local peak in the oxygen ion velocity distribution is represented by an isotropic shell distribution. Kinetic linear dispersion theory then predicts unstable Bernstein modes at or near the harmonics of ΩO+ and at propagation quasi-perpendicular to the background magnetic field, B0. If the cold ions are mostly protons, these unstable modes are characterized by a low compressibility (|δB∥|2/|δB|2≲0.01), a small phase speed (vph˜0.2vA), a relatively small ratio of the electric field energy to the magnetic field energy (between 10-4 and 10-3), and the Poynting vector directed almost parallel to B0. These linear properties are overall in good agreement with the properties of the observed waves. We demonstrate that superposition of the predicted unstable Bernstein modes at quasi-perpendicular propagation can produce the observed polarization properties, including the minimum variance direction on average almost parallel to B0.

  6. [Properties of cholinergic receptor-mediated ion channels on type I vestibular hair cells of guinea pigs].

    Science.gov (United States)

    Zhu, Yun; Kong, Wei-Jia; Xia, Jiao; Zhang, Yu; Cheng, Hua-Mao; Guo, Chang-Kai

    2008-06-25

    To confirm the existence of cholinergic receptors on type I vestibular hair cells (VHCs I) of guinea pigs and to study the properties of the cholinergic receptor-mediated ion channels on VHCs I, electrophysiological responses of isolated VHCs I to external ACh were examined by means of whole-cell patch-clamp recordings. The results showed that 7.5% (21/279) VHCs I were found to be sensitive to ACh (10-1000 μmol/L). ACh generated an outward current in a steady, slow, dose-dependent [EC(50) was (63.78±2.31) μmol/L] and voltage-independent manner. In standard extracellular solution, ACh at the concentration of 100 μmol/L triggered a calcium-dependent current of (170±15) pA at holding potential of -50 mV, and the current amplitude could be depressed by extracellularly added calcium-dependent potassium channel antagonist TEA. The time interval for the next complete activation of ACh-sensitive current was no less than 1 min. The ion channels did not shut off even when they were exposed to ACh for an extended period of time (8 min). The results suggest that dose-dependent, calcium-dependent and voltage-independent cholinergic receptors were located on a few of the VHCs I investibular epithelium of guinea pigs. The cholinergic receptors did not show desensitization to ACh. This work reveals the existence of efferent neurotransmitter receptors on VHCs I and helps in understanding the function of vestibular efferent nervous system, and may provide some useful information on guiding the clinical rehabilitative treatment of vertigo.

  7. Studies in ion source development for application in heavy ion fusion

    Energy Technology Data Exchange (ETDEWEB)

    Kapica, Jonathan G. [Univ. of California, Berkeley, CA (United States)

    2004-05-01

    The overall purpose of these experiments is to contribute to the development of ion injector technology in order to produce a driver for use in a heavy-ion-fusion (HIF) power generating facility. The overall beam requirements for HIF are quite demanding; a short list of the constraints is the following: (1) Low cost (a large portion of overall cost will come from the beam system); (2) Bright, low emittance beam; (3) Total beam energy 5MJ; (4) Spot size 3mm (radius); (5) Pulse Duration 10ns; (6) Current on target 40kA; (7) Repetition Rate 5Hz; (8) Standoff from target 5m; and (9) Transverse Temp < 1 keV. The reasons for employing ion beams in inertial fusion systems become obvious when the repetition rate required is considered. While laser drivers are useful in producing a proof-of-concept, they will be incapable of application in power generation. Consequently attempts in the U.S. to achieve a power generating system make use of linear ion accelerators. It is apparent that the accelerator system requires the highest quality input as obtainable. Therefore injector design is an essential portion of the entire inertial fusion system. At Lawrence Berkeley and Lawrence Livermore National Laboratories experiments are being conducted using two injector formats. For this project I have conducted a series of studies using both. The next two sections provide a brief description of the sources used for my experiments.

  8. An ion species model for positive ion sources - part II analysis of hydrogen isotope effects

    CERN Document Server

    Surrey, E

    2014-01-01

    A one dimensional model of the magnetic multipole volume plasma source has been developed for application to intense ion/neutral atom beam injectors. The model uses plasma transport coefficients for particle and energy flow to create a detailed description of the plasma parameters along an axis parallel to that of the extracted beam. In this paper the isotopic modelling of positive hydrogenic ions is considered and compared with experimental data from the neutral beam injectors of the Joint European Torus. The use of the code to gain insights into the processes contributing to the ratios of the ionic species is demonstrated and the conclusion is drawn that 75% of the atomic ion species arises from ionization of dissociated molecules and 25% from dissociation of the molecular ions. However whilst the former process is independent of the filter field, the latter is sensitive to the change in distribution of fast and thermal electrons produced by the magnetic filter field and an optimum combination of field stre...

  9. Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL.

    Science.gov (United States)

    Zhao, H W; Sun, L T; Zhang, X Z; Guo, X H; Cao, Y; Lu, W; Zhang, Z M; Yuan, P; Song, M T; Zhao, H Y; Jin, T; Shang, Y; Zhan, W L; Wei, B W; Xie, D Z

    2008-02-01

    There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

  10. Effects of Residual Hypochlorite Ion on Methane Production during the Initial Anaerobic Digestion Stage of Pig Slurry.

    Science.gov (United States)

    Yoon, Young-Man; Kim, Hyun-Cheol; So, Kyu-Ho; Kim, Chang-Hyun

    2013-01-01

    The hypochlorite ion (OCl(-)) is a widely used disinfecting agent in pig rearing in Korea, but its residual effect on CH4 production from pig slurry is unclear. The objective of this study was to investigate the inhibition effects of residual OCl(-) on CH4 production during the initial anaerobic digestion stage of pig slurry. Three organic concentrations (9.9, 26.2 and 43.7 g/L) of volatile solids (VS) were tested with the addition of 52.3 mg/L OCl(-), ten times of the typical concentration used in Korea, or without OCl(-) (Control) in anaerobic batch culture. The culture was run under mesophilic (38°C) conditions for 20 d. At the lowest organic concentration with OCl(-), the VS degradation was 10.3% lower (pOCl(-), it did not differ from Control. CH4 yields were higher in the control treatments than their OCl(-) counterpart cultures, and CH4 yields of Control and OCl(-) treatments at the organic concentrations of 9.9, 26.2 and 43.7 g/L differed in the probability level (p) of 0.31, 0.04, and 0.06, respectively. Additionally, CH4 concentration increased steeply and reached 70.0% within 4 d in the absence OCl(-), but a gradual increase up to 60.0% was observed in 6 d in the OCl(-) treated cultures. The Rm (the maximum specific CH4 production rate) and λ (lag phase time) of 9.9 g/L with OCl(-) were 8.1 ml/d and 25.6 d, while the Rm was increased to 15.1 ml/d, and λ was reduced to 11.4 d in PS-III (higher organic concentration) with OCl(-). The results suggest that a prolonged fermentation time was necessary for the methanogens to overcome the initial OCl(-) inhibitory effect, and an anaerobic reactor operated with high organic loadings was more advantageous to mitigate the inhibitory effect of residual hypochlorite ion.

  11. Effects of dietary vitamin E concentration and source on sow, milk, and pig concentrations of α-tocopherol.

    Science.gov (United States)

    Shelton, N W; Dritz, S S; Nelssen, J L; Tokach, M D; Goodband, R D; DeRouchey, J M; Yang, H; Hill, D A; Holzgraefe, D; Hall, D H; Mahan, D C

    2014-10-01

    A total of 126 gilts and sows (PIC 1050) and their litters were used to determine the effects of dietary vitamin E concentration and source on sow plasma, milk, and pig concentrations of α-tocopherol. Additionally, we estimated the bioavailability of D-α-tocopheryl acetate (D-α-TAc) relative to DL-α-tocopheryl acetate (DL-α-TAc) when fed in diets containing dried distillers grains with solubles (DDGS). The 6 dietary treatments included DL-α-TAc at 44 and 66 mg/kg and D-α-TAc at 11, 22, 33, and 44 mg/kg. From breeding to d 69 of gestation, sows were fed 2.0 kg/d of a diet containing 40% DDGS, 0.30 mg/kg added Se, and no added vitamin E. Vitamin E treatments were fed from d 70 of gestation through weaning. Plasma was collected from sows on d 69 and 100 of gestation, at farrowing, and at weaning. Colostrum and milk samples were also collected. Plasma from 3 pigs per litter and heart and liver samples from 1 pig per litter were collected at weaning. Plasma, milk, and tissues from 6 litters per treatment were analyzed for α-tocopherol. Although tissue, plasma, and milk concentrations of α-tocopherol were the primary response criteria of interest, sow and litter performance were measured. As expected, treatment effects were not observed for lactation feed intake, sow BW, or backfat measurements. A trend (P = 0.085) for a treatment effect on average pig BW at weaning was detected, with pigs nursing sows fed 44 mg/kg DL-α-TAc weighing less because of a younger weaning age. No other differences in litter performance were observed. As D-α-TAc increased in the diet, sow plasma, colostrum, and milk, pig plasma, and pig heart concentrations of α-tocopherol increased (linear, P Sows fed diets with 44 mg/kg D-α-TAc had increased (P sows fed 44 mg/kg of DL-α-TAc. Sows fed 66 mg/kg DL-α-TAc also had greater (P = 0.022) plasma α-tocopherol at weaning than sows fed 44 mg/kg DL-α-TAc. Bioavailability coefficients for D-α-TAc relative to DL-α-TAc ranged from 1.9 to 4

  12. Performance optimization of H(-) multicusp ion source for KIRAMS-30 cyclotron.

    Science.gov (United States)

    Kang, Kun Uk; An, Dong Hyun; Chang, Hong Suk; Chai, Jong Seo

    2008-02-01

    KIRAMS-30 cyclotron has been developed and implemented for radio isotope production. For the purpose of producing negative hydrogen ions and low energy beam injection to the central region of KIRAMS-30, 10 mA H(-) multicusp ion source with beam kinetic energies in the 20-30 keV range and the normalized 4 rms emittance less than 1 mm mrad was installed. The optimized ion source operating condition is presented and the correlation between the extracted beam current and ion source parameters is described for the performance enhancement of the ion source.

  13. Performance optimization of H- multicusp ion source for KIRAMS-30 cyclotrona)

    Science.gov (United States)

    Kang, Kun Uk; An, Dong Hyun; Chang, Hong Suk; Chai, Jong Seo

    2008-02-01

    KIRAMS-30 cyclotron has been developed and implemented for radio isotope production. For the purpose of producing negative hydrogen ions and low energy beam injection to the central region of KIRAMS-30, 10mA H- multicusp ion source with beam kinetic energies in the 20-30keV range and the normalized 4rms emittance less than 1mm mrad was installed. The optimized ion source operating condition is presented and the correlation between the extracted beam current and ion source parameters is described for the performance enhancement of the ion source.

  14. ECR Ion Source of High Charge States%高电荷态ECR离子源

    Institute of Scientific and Technical Information of China (English)

    张子民; 刘占稳; 赵红卫

    2000-01-01

    介绍了目前ECR离子源的发展状况和国际上几台典型的ECR离子源.%Electron cyclotron resonance (ECR) ion source is the most efficient facility for producing highly charged ions.So far more than 1 emA of O6+ and 0.02eμA of U55+ have been delivered by ECR ion source. In this paper the latest develop-ment of ECR ion source is presented and several typical ECR ion sources in the world is introduced.

  15. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    2003-01-01

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  16. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  17. Ion source parameters and hydrogen scrambling in the ECD of selectively deuterated peptides

    DEFF Research Database (Denmark)

    Duchateau, Magalie; Jørgensen, Thomas J. D.; Robine, Ophélie

    2014-01-01

    . In the present work, we investigate the occurrence of scrambling in the Apollo I electrospray ion source using ECD of selectively deuterium labeled peptides. The electrospray ion source settings leading to minimal scrambling were identified. Furthermore, an energy dependent loss of deuterium occurring in the ion...

  18. Multi-ion sensing of dipolar noise sources in ion traps

    Science.gov (United States)

    Galve, F.; Alonso, J.; Zambrini, R.

    2017-09-01

    Trapped-ion quantum platforms are subject to "anomalous" heating due to interactions with electric-field noise sources of nature not yet completely known. There is ample experimental evidence that this noise originates at the surfaces of the trap electrodes, and models assuming fluctuating pointlike dipoles are consistent with observations, but the exact microscopic mechanisms behind anomalous heating remain undetermined. Here we show how a two-ion probe displays a transition in its dissipation properties, enabling experimental access to the mean orientation of the dipoles and the spatial extent of dipole-dipole correlations. This information can be used to test the validity of candidate microscopic models, which predict correlation lengths spanning several orders of magnitude. Furthermore, we propose an experiment to measure these effects with currently available traps and techniques.

  19. Study of the negative ion extraction mechanism from a double-ion plasma in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Goto, I.; Nishioka, S.; Hatayama, A. [Graduate school of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan)

    2015-04-08

    We have developed a 2D3V-PIC model of the extraction region, aiming to clarify the basic extraction mechanism of H{sup −} ions from the double-ion plasma in H{sup −} negative ion sources. The result shows the same tendency of the H{sup −} ion density n{sub H{sup −}} as that observed in the experiments, i.e.,n{sub H{sup −}} in the upstream region away from the plasma meniscus (H{sup −} emitting surface) has been reduced by applying the extraction voltage. At the same time, relatively slow temporal oscillation of the electric potential compared with the electron plasma frequency has been observed in the extraction region. Results of the systematic study using a 1D3V-PIC model with the uniform magnetic field confirm the result that the electrostatic oscillation is identified to be lower hybrid wave. The effect of this oscillation on the H{sup −} transport will be studied in the future.

  20. Operational Experience with The GTS-LHC Ion Source and Future Developments of The CERN Ion Injector

    CERN Document Server

    Kuchler, D; Lombardi, A; O'Neil, M; Scrivens, R; Stafford-Haworth, J; Thomae, R

    2012-01-01

    Since 2010 the GTS-LHC source delivers lead ions for heavy ion physics at the LHC. Several modifications allowed the improvement the source reliability and the beam stability. The attempts to improve the beam intensity were less successful. The different modifications and actual performance figures will be presented in this paper. In addition to the heavy ion physics program of the LHC new ion species will be requested for different experiments in the future. The fixed target experiment NA61 requires primary argon and xenon beams. And a future biomedical facility asks for light ions in the range helium to neon. Approaches to prepare these beams and to modify the ion injector towards a light ion front end are presented.

  1. Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Kitagawa, A.; Drentje, A. G.; Fujita, T.; Muramatsu, M. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Fukushima, K.; Shiraishi, N.; Suzuki, T.; Takahashi, K.; Takasugi, W. [Accelerator Engineering Corporation, Chiba (Japan); Biri, S.; Rácz, R. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Kato, Y. [Graduate School of Engineering, Osaka University, Osaka (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe (Japan)

    2016-02-15

    With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

  2. ATLAS 10 GHz electron cyclotron resonance ion source upgrade project

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, D. P. [Argonne National Laboratory, Physics Division, Argonne, Illinois 60439 (United States); Vondrasek, R. [Argonne National Laboratory, Physics Division, Argonne, Illinois 60439 (United States); Pardo, R. C. [Argonne National Laboratory, Physics Division, Argonne, Illinois 60439 (United States); Xie, D. [Berkeley Ion Equipment Inc., Santa Clara, California 95054 (United States)

    2000-02-01

    A major upgrade of the first ATLAS 10 GHz electron cyclotron resonance (ECR) ion source, which began operations in 1987, is in the planning and procurement phase. The new design will convert the old two-stage source into a single-stage source with an electron donor disk and high gradient magnetic field that preserves radial access for solid material feeds and pumping of the plasma chamber. The new magnetic-field profile allows for the possibility of a second ECR zone at a frequency of 14 GHz. An open hexapole configuration, using a high-energy-product Nd-Fe-B magnet material, having an inner diameter of 8.8 cm and pole gaps of 2.4 cm, has been adopted. Models indicate that the field strengths at the chamber wall, 4 cm in radius, will be 9.3 kG along the magnet poles and 5.6 kG along the pole gaps. The individual magnet bars will be housed in austenitic stainless steel, allowing the magnet housing within the aluminum plasma chamber to be used as a water channel for direct cooling of the magnets. Eight solenoid coils from the existing ECR will be enclosed in an iron yoke to produce the axial mirror. Based on a current of 500 A, the final model predicts a minimum B field of 3 kG with injection and extraction mirror ratios of 4.4 and 2.9, respectively. (c) 2000 American Institute of Physics.

  3. ATLAS 10 GHz ECR ions source upgrade project.

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, D. P.; Pardo, R. C.; Vondrasek, R.; Xie, D.

    1999-08-10

    A major upgrade of the first ATLAS 10 GHz ECR ion source, which began operations in 1987, is in the planning and procurement phase. The new design will convert the old two-stage source into a single-stage source with an electron donor disk and high gradient magnetic field that preserves radial access for solid material feeds and pumping of the plasma chamber. The new magnetic field profile allows for the possibility of a second ECR zone at a frequency of 14 GHz. An open hexapole configuration, using a high energy-product Nd-Fe-B magnet material, having an inner diameter of 8.8 cm and pole gaps of 2.4 cm has been adopted. Models indicate that the field strengths at the chamber wall, 4 cm in radius, will be 9.3 kG along the magnet poles and 5.6 kG along the pole gaps. The individual magnet bars will be housed in austenitic stainless steel allowing the magnet housing within the aluminum plasma chamber to be used as a water channel for direct cooling of the magnets. Eight solenoid coils from the existing ECR will be enclosed in an iron yoke to produce the axial mirror. Based on a current of 500 A, the final model predicts a minimum B field of 3 kG with injection and extraction mirror ratios of 4.4 and 2.9 respectively.

  4. Immobilized aptamer paper spray ionization source for ion mobility spectrometry.

    Science.gov (United States)

    Zargar, Tahereh; Khayamian, Taghi; Jafari, Mohammad T

    2017-01-05

    A selective thin-film microextraction based on aptamer immobilized on cellulose paper was used as a paper spray ionization source for ion mobility spectrometry (PSI-IMS), for the first time. In this method, the paper is not only used as an ionization source but also it is utilized for the selective extraction of analyte, based on immobilized aptamer. This combination integrates both sample preparation and analyte ionization in a Whatman paper. To that end, an appropriate sample introduction system with a novel design was constructed for the paper spray ionization source. Using this system, a continuous solvent flow works as an elution and spray solvent simultaneously. In this method, analyte is adsorbed on a triangular paper with immobilized aptamer and then it is desorbed and ionized by elution solvent and applied high voltage on paper, respectively. The effects of different experimental parameters such as applied voltage, angle of paper tip, distance between paper tip and counter electrode, elution solvent type, and solvent flow rate were optimized. The proposed method was exhaustively validated in terms of sensitivity and reproducibility by analyzing the standard solutions of codeine and acetamiprid. The analytical results obtained are promising enough to ensure the use of immobilized aptamer paper-spray as both the extraction and ionization techniques in IMS for direct analysis of biomedicine. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Preliminary Tests Of The Decris-sc Ion Source

    CERN Document Server

    Efremov, A; Bechterev, V; Bogomolov, S L; Bondarenko, P G; Datskov, V I; Dmitriev, S; Drobin, V; Lebedev, A; Leporis, M; Malinowski, H; Nikiforov, A; Paschenko, S V; Seleznev, V; Shishov, Yu A; Smirnov, Yu; Tsvineva, G; Yakovlev, B; Yazvitsky, N Yu

    2004-01-01

    A new "liquid He-free" superconducting Electron Cyclotron Resonance Ion Source DECRIS-SC, to be used as injector for the IC-100 small cyclotron, has been designed by FLNR and LHE JINR. The main feature is that a compact refrigerator of Gifford-McMahon type is used to cool the solenoid coils. For the reason of very small cooling power at 4.2 K (about 1 W) our efforts were to optimize the magnetic structure and minimize an external heating of the coils. The maximum magnetic field strength is 3 T and 2 T in injection and extraction region respectively. For the radial plasma confinement a hexapole made of NdFeB permanent magnet is used. The source will be capable of ECR plasma heating using different frequencies (14 GHz or 18 GHz). To be able to deliver usable intensities of solids, the design is also allow axial access for evaporation oven and metal samples using the plasma sputtering technique. Very preliminary results of the source test are presented.

  6. ATLAS 10 GHz electron cyclotron resonance ion source upgrade project

    CERN Document Server

    Moehs, D P; Pardo, R C; Xie, D

    2000-01-01

    A major upgrade of the first ATLAS 10 GHz electron cyclotron resonance (ECR) ion source, which began operations in 1987, is in the planning and procurement phase. The new design will convert the old two-stage source into a single-stage source with an electron donor disk and high gradient magnetic field that preserves radial access for solid material feeds and pumping of the plasma chamber. The new magnetic-field profile allows for the possibility of a second ECR zone at a frequency of 14 GHz. An open hexapole configuration, using a high-energy-product Nd-Fe-B magnet material, having an inner diameter of 8.8 cm and pole gaps of 2.4 cm, has been adopted. Models indicate that the field strengths at the chamber wall, 4 cm in radius, will be 9.3 kG along the magnet poles and 5.6 kG along the pole gaps. The individual magnet bars will be housed in austenitic stainless steel, allowing the magnet housing within the aluminum plasma chamber to be used as a water channel for direct cooling of the magnets. Eight solenoid...

  7. Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    A. Kürten

    2010-11-01

    Full Text Available The performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS through the reaction of NO3 ions with H2SO4. The ion source is operated under atmospheric pressure and its design is similar to the one of a radioactive (Americium 241 ion source which has been used previously. Our results show that the detection limit for the corona ion source is sufficiently good for most applications. For an integration time of one minute it is ~6 × 104 molecules of H2SO4 per cm3. In addition, only a small cross-sensitivity to SO2 has been observed for concentrations as high as 1 ppmv in the sample gas. This low sensitivity to SO2 is achieved even without the addition of an OH scavenger. When comparing the new corona ion source with the americium ion source for the same provided H2SO4 concentration, both ion sources yield almost identical values. These features make the corona ion source investigated here favorable over the more commonly used radioactive ion sources for most applications where H2SO4 is measured by CIMS.

  8. Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    A. Kürten

    2011-03-01

    Full Text Available The performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS through the reaction of NO3 ions with H2SO4. The ion source is operated under atmospheric pressure and its design is similar to the one of a radioactive (americium-241 ion source which has been used previously. The results show that the detection limit for the corona ion source is sufficiently good for most applications. For an integration time of 1 min it is ~6 × 104 molecule cm−3 of H2SO4. In addition, only a small cross-sensitivity to SO2 has been observed for concentrations as high as 1 ppmv in the sample gas. This low sensitivity to SO2 is achieved even without the addition of an OH scavenger. When comparing the new corona ion source with the americium ion source for the same provided H2SO4 concentration, both ion sources yield almost identical values. These features make the corona ion source investigated here favorable over the more commonly used radioactive ion sources for most applications where H2SO4 is measured by CIMS.

  9. Combined corona discharge and UV photoionization source for ion mobility spectrometry.

    Science.gov (United States)

    Bahrami, Hamed; Tabrizchi, Mahmoud

    2012-08-15

    An ion mobility spectrometer is described which is equipped with two non-radioactive ion sources, namely an atmospheric pressure photoionization and a corona discharge ionization source. The two sources cannot only run individually but are additionally capable of operating simultaneously. For photoionization, a UV lamp was mounted parallel to the axis of the ion mobility cell. The corona discharge electrode was mounted perpendicular to the UV radiation. The total ion current from the photoionization source was verified as a function of lamp current, sample flow rate, and drift field. Simultaneous operation of the two ionization sources was investigated by recording ion mobility spectra of selected samples. The design allows one to observe peaks from either the corona discharge or photoionization individually or simultaneously. This makes it possible to accurately compare peaks in the ion mobility spectra from each individual source. Finally, the instrument's capability for discriminating two peaks appearing in approximately identical drift times using each individual ionization source is demonstrated.

  10. Salmon protein hydrolysate as a protein source in feed for young pigs

    DEFF Research Database (Denmark)

    Nørgaard, Jan Værum; Blaabjerg, Karoline; Poulsen, Hanne Damgaard

    2012-01-01

    Salmon protein hydrolysate (SPH) is made from fresh by-products from farmed salmon that are minced and acidified to hydrolyse proteins into peptides and free amino acids. The objective of this study was to evaluate SPH in young pigs compared to soy protein concentrate (SPC), fish meal (FM...

  11. Digestible and Metabolizable Energy Content of Crude Glycerin Originating from Different Sources in Growing Pigs

    Science.gov (United States)

    Apparent digestible (DE) and metabolizable (ME) of various crude glycerins from different biodiesel production facilities were empirically determined in nursery pigs (10.4 kg initial body weight) in order to predict the DE and ME based on crude glycerin composition. Dietary treatments consisted of a...

  12. Study of negative ion transport phenomena in a plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Riz, D.; Pamela, J. [Departement de Recherches sur la Fusion Controlee C. E., Cadarache, 13108 St-Paul-lez-Durance Cedex (France)

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H{sup {minus}}/H{sup +}) and charge exchanges (H{sup {minus}}/H{sup 0}). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter. {copyright} {ital 1996 American Institute of Physics.}

  13. Study of negative ion transport phenomena in a plasma source

    Science.gov (United States)

    Riz, D.; Paméla, J.

    1996-07-01

    NIETZSCHE (Negative Ions Extraction and Transport ZSimulation Code for HydrogEn species) is a negative ion (NI) transport code developed at Cadarache. This code calculates NI trajectories using a 3D Monte-Carlo technique, taking into account the main destruction processes, as well as elastic collisions (H-/H+) and charge exchanges (H-/H0). It determines the extraction probability of a NI created at a given position. According to the simulations, we have seen that in the case of volume production, only NI produced close to the plasma grid (PG) can be extracted. Concerning the surface production, we have studied how NI produced on the PG and accelerated by the plasma sheath backward into the source could be extracted. We demonstrate that elastic collisions and charge exchanges play an important role, which in some conditions dominates the magnetic filter effect, which acts as a magnetic mirror. NI transport in various conditions will be discussed: volume/surface production, high/low plasmas density, tent filter/transverse filter.

  14. Review of ISOL target-ion-source systems

    CERN Document Server

    Kirchner, R

    2003-01-01

    Any review of target-ion-source systems (TISS) is necessarily a variation of the ISOL-theme 'efficient, fast, selective'. In the first part, more than 30 years of TISS development are examined in view of these key characteristics. By looking at the lines of development that were successful, at the lines that were abandoned (partly for good, partly for less good reasons), the lines with the most promising perspectives emerge. The second part deals with on-line chemistry in the TISS and its possibly double benefits: enhanced selectivity or increased separation speed, or both in favourable cases, as the relatively new sulfide chemistry. For the group-IVa-elements germanium and tin, the separation as sulfide-ions does not only suppress strongly the contamination by the neighbouring elements. It also reduces the effusion part of the release by orders of magnitude to the level of the intrinsic delay caused by molecular flow. The homologue chemistry is likely to work for silicon, but not for lead. While selectivity ...

  15. Sheath overlap during very large scale plasma source ion implantation

    Science.gov (United States)

    Cluggish, B. P.; Munson, C. P.

    1998-12-01

    Measurements of plasma source ion implantation have been performed on a large target of complex geometry. The target consists of 1000 aluminum, automotive piston surrogates mounted on four racks; total surface area is over 16 m2. The four racks are positioned parallel to each other, 0.25 m apart, in an 8 m3 vacuum chamber. The racks of pistons are immersed in a capacitive radio frequency plasma, with an argon gas pressure of 20-65 mPa. Langmuir probe measurements indicate that the plasma density profile is highly nonuniform, due to particle losses to the racks of pistons. The plasma ions are implanted into the pistons by pulse biasing the workpiece to negative voltages as low as -18 kV for up to 20 μs. During the voltage pulse, the high-voltage sheaths from adjacent racks of pistons converge towards each other. At plasma densities less than 109 cm-3 the sheaths are observed to overlap. Measurements of the sheath overlap time are compared with standard analytic theory and with simulations run with a two-dimensional particle-in-cell code.

  16. Anion formation in sputter ion sources by neutral resonant ionization

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, J. S., E-mail: johnsvogel@yahoo.com [University of California, 8300 Feliz Creek Dr., Ukiah, California 95482 (United States)

    2016-02-15

    Focused Cs{sup +} beams in sputter ion sources create mm-diameter pits supporting small plasmas that control anionization efficiencies. Sputtering produces overwhelmingly neutral products that the plasma can ionize as in a charge-change vapor. Electron capture between neutral atoms rises as the inverse square of the difference between the ionization potential of the Cs state and the electron affinity of the sputtered atom, allowing resonant ionization at very low energies. A plasma collision-radiation model followed electronic excitation up to Cs(7d). High modeled Cs(7d) in a 0.5 mm recess explains the 80 μA/mm{sup 2} C{sup −} current density compared to the 20 μA/mm{sup 2} from a 1 mm recess.

  17. RF Plasma modeling of the Linac4 H− ion source

    CERN Document Server

    Mattei, S; Hatayama, A; Lettry, J; Kawamura, Y; Yasumoto, M; Schmitzer, C

    2013-01-01

    This study focuses on the modelling of the ICP RF-plasma in the Linac4 H− ion source currently being constructed at CERN. A self-consistent model of the plasma dynamics with the RF electromagnetic field has been developed by a PIC-MCC method. In this paper, the model is applied to the analysis of a low density plasma discharge initiation, with particular interest on the effect of the external magnetic field on the plasma properties, such as wall loss, electron density and electron energy. The use of a multi-cusp magnetic field effectively limits the wall losses, particularly in the radial direction. Preliminary results however indicate that a reduced heating efficiency results in such a configuration. The effect is possibly due to trapping of electrons in the multi-cusp magnetic field, preventing their continuous acceleration in the azimuthal direction.

  18. Generation of ions in a pulsed ion source with an interface based on a polymer track membrane

    Science.gov (United States)

    Balakin, A. A.; Khidirov, S. G.; Buido, E. A.

    2016-10-01

    The time-of-flight spectra of ions generated during the extraction of negative ions from the KI solution in water-glycerin mixture by high-strength electric field pulses are studied using a source with an interface based on a polymer track membrane. It has been shown that the ions formed in secondary processes of bombardment of the membrane surface make a considerable contribution to the observed spectra. It has been found that the peaks of negative hydrogen ions have the highest intensity in the spectrum, indicating effective emission of these ions during the bombardment of polyethylene terephthalate by secondary ions with an energy of about 6 keV. The main trends in the modification of the membrane interface to reduce the fraction of secondary ions in the ion beam have been outlined.

  19. Computer simulation of the emission process of some field emission alloy ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Georgieva, S.; Vichev, R.; Drandarov, N. [Bulgarian Academy of Sciences, Sofia (Bulgaria)

    1996-10-01

    The ion emission process from InGa, AuBe and AuSi field emission alloy ion sources (LAIS) is simulated. Field strength is calculated using the SOC model. Paraxial source size, beam spot size, energy and angular distributions are estimated. The effects on the emission characteristics of Coulomb interaction between ions are investigated, and the strong influences of ion mass and charge are also shown. (Author).

  20. An ion species model for positive ion sources - part I description of the model

    CERN Document Server

    Surrey, E

    2014-01-01

    A one dimensional model of the magnetic multipole volume plasma source has been developed for use in intense ion/neutral atom beam injectors. The model uses plasma transport coefficients for particle and energy flow to create a detailed description of the plasma parameters along an axis parallel to that of the extracted beam. Primarily constructed for applications to neutral beam injection systems on fusion devices, the model concentrates on the hydrogenic isotopes but can be extended to any gas by substitution of the relevant masses, cross sections and rate coefficients. The model considers the flow of fast ionizing electrons that create the ratios of the three hydrogenic isotope ion species, H+, H2 +, H3 + (and similarly for deuterium and tritium) as they flow towards the beam extraction electrode, together with the production of negative hydrogenic ions through volume processes. The use of detailed energy balance in the discharge allows the determination of the fraction of the gas density that is in an ato...

  1. Charge Breeding of Radioactive Ions in an Electron Cyclotron Resonance Ion Source(ECRIS) at ISOLDE

    CERN Multimedia

    Lindroos, M

    2002-01-01

    The development of an efficient charge breeding scheme for the next generation of RIB facilities will have a strong impact on the post-accelerator for several Radioactive Ion Beam (RIB) projects at European large scale facilities. At ISOLDE/CERN there will be the unique possibility to carry out experiments with the two possible charge breeding set-ups with a large variety of radioactive isotopes using identical injection conditions. One charge breeding set-up is the Penning trap/EBIS combination which feeds the REX-ISOLDE linear accelerator and which is in commissioning now. The second charge breeder is a new ECRIS PHOENIX developed at the ISN ion source laboratory at Grenoble. This ECRIS is now under investigation with a 14 GHz amplifier to characterize its performance. The experiments are accompanied by theoretical studies in computer simulations in order to optimize the capture of the ions in the ECRIS plasma. A second identical PHOENIX ECRIS which is under investigation at the Daresbury Laboratory is avai...

  2. GaBi alloy liquid metal ion source for microelectronics research.

    Science.gov (United States)

    Bischoff, L; Pilz, W; Ganetsos, Th; Forbes, R G; Akhmadaliev, Ch

    2007-09-01

    A GaBi alloy liquid metal ion source has been studied. From an analysis of the source mass spectra as a function of emission current, a mechanism is suggested for the production of single- and double-charged ions. There is good agreement with the results of Swanson's investigations of a pure Bi source.

  3. Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of ^{23}Na^{1+} ions

    Directory of Open Access Journals (Sweden)

    O. Tarvainen

    2016-05-01

    Full Text Available This work describes the utilization of an injected ^{23}Na^{1+} ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 10^{11}  cm^{-3} or higher. The experimental results are compared to simulations of the ^{23}Na^{1+} capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

  4. Analysis of plasma distribution near the extraction region in surface produced negative ion sources.

    Science.gov (United States)

    Fukano, A; Hatayama, A

    2014-02-01

    In study of a negative ion source, it is important to understand the plasma characteristics near the extraction region. A recent experiment in the NIFS-R&D ion source has suggested that a "double ion plasma layer" which is a region consisting of hydrogen positive and negative ions exists near the plasma grid (PG). Density distribution of plasma near the extraction region is studied analytically. It is shown that the density distribution depends on an amount of the surface produced negative ions and the double ion plasma layer is formed near the PG surface for the case of strong surface production.

  5. Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operationa)

    Science.gov (United States)

    Lettry, J.; Alessi, J.; Faircloth, D.; Gerardin, A.; Kalvas, T.; Pereira, H.; Sgobba, S.

    2012-02-01

    Linac4 accelerator of Centre Européen de Recherches Nucléaires is under construction and a RF-driven H- ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H-, electrons, and Cs- ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

  6. Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation

    Energy Technology Data Exchange (ETDEWEB)

    Lettry, J.; Gerardin, A.; Pereira, H.; Sgobba, S. [CERN, 1211 Geneva 23 (Switzerland); Alessi, J. [BNL, P.O. Box 5000, Upton, New York 11973-5000 (United States); Faircloth, D. [RAL, Harwell Oxford, Didcot OX11 0QX (United Kingdom); Kalvas, T. [University of Jyvaskyla, P.O.Box 35, FI-40014 (Finland)

    2012-02-15

    Linac4 accelerator of Centre Europeen de Recherches Nucleaires is under construction and a RF-driven H{sup -} ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H{sup -}, electrons, and Cs{sup -} ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

  7. Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation

    Energy Technology Data Exchange (ETDEWEB)

    Lettry J.; Alessi J.; Faircloth, D.; Gerardin, A.; Kalvas, T.; Pereira, H.; Sgobba, S.

    2012-02-23

    Linac4 accelerator of Centre Europeen de Recherches Nucleaires is under construction and a RF-driven H{sup -} ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H{sup -}, electrons, and Cs{sup -} ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

  8. Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation.

    Science.gov (United States)

    Lettry, J; Alessi, J; Faircloth, D; Gerardin, A; Kalvas, T; Pereira, H; Sgobba, S

    2012-02-01

    Linac4 accelerator of Centre Européen de Recherches Nucléaires is under construction and a RF-driven H(-) ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H(-), electrons, and Cs(-) ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

  9. Development of an ion source for volatile elements at DREAMS

    Energy Technology Data Exchange (ETDEWEB)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Merchel, Silke; Rugel, Georg [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Ion Beam Physics and Materials Research, Dresden (Germany)

    2012-07-01

    After successful measurements of {sup 10}Be, {sup 26}Al and {sup 41}Ca at DREAMS (DResden Accelerator Mass Spectrometry), extensive test measurements of {sup 36}Cl started. Besides the challenge of separating the stable isobar {sup 36}S, which at DREAMS is accomplished by post-stripping and a split-anode-ionization-chamber, the problem of ion source memory must be solved. To characterize this effect we use {sup 35}Cl/{sup 37}Cl samples of natural composition and {sup 35}Cl-enriched samples with a {sup 35}Cl/{sup 37}Cl-ratio >100. Similar measurements at the French AMS facility ASTER showed differences of 2-4% in the {sup 35}Cl/{sup 37}Cl ratios of the highly enriched samples after 24 h of sputtering samples with natural isotopic ratios. To minimize the long-term-memory effect, two modified designs of the original source (HVEE) were constructed at DREAMS. A more open geometry was used to improve the vacuum level, and parts of the target loading system were modified to allow the exchange of the individual cathode aperture with each target.

  10. High efficiency noble gas electron impact ion source for isotope separation

    Energy Technology Data Exchange (ETDEWEB)

    Appelhans, A. D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Olson, J. E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Dahl, D. A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ward, M. B. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-07-01

    An electron impact ion source has been designed for generation of noble gas ions in a compact isotope separator. The source utilizes a circular filament that surrounds an ionization chamber, enabling multiple passes of electrons through the ionization chamber. This report presents ion optical design and the results of efficiency and sensitivity measurements performed in an ion source test chamber and in the compact isotope separator. The cylindrical design produced xenon ions at an efficiency of 0.37% with a sensitivity of ~24 µA /Pa at 300 µA of electron current.

  11. Simulation of RF power and multi-cusp magnetic field requirement for H- ion sources

    Science.gov (United States)

    Pathak, Manish; Senecha, V. K.; Kumar, Rajnish; Ghodke, Dharmraj. V.

    2016-12-01

    A computer simulation study for multi-cusp RF based H- ion source has been carried out using energy and particle balance equation for inductively coupled uniformly dense plasma considering sheath formation near the boundary wall of the plasma chamber for RF ion source used as high current injector for 1 Gev H- Linac project for SNS applications. The average reaction rates for different reactions responsible for H- ion production and destruction have been considered in the simulation model. The RF power requirement for the caesium free H- ion source for a maximum possible H- ion beam current has been derived by evaluating the required current and RF voltage fed to the coil antenna using transformer model for Inductively Coupled Plasma (ICP). Different parameters of RF based H- ion source like excited hydrogen molecular density, H- ion density, RF voltage and current of RF antenna have been calculated through simulations in the presence and absence of multicusp magnetic field to distinctly observe the effect of multicusp field. The RF power evaluated for different H- ion current values have been compared with the experimental reported results showing reasonably good agreement considering the fact that some RF power will be reflected from the plasma medium. The results obtained have helped in understanding the optimum field strength and field free regions suitable for volume emission based H- ion sources. The compact RF ion source exhibits nearly 6 times better efficiency compare to large diameter ion source.

  12. High temperature electron beam ion source for the production of single charge ions of most elements of the Periodic Table

    CERN Document Server

    Panteleev, V N; Barzakh, A E; Fedorov, D V; Ivanov, V S; Moroz, F V; Orlov, S Y; Seliverstov, D M; Stroe, L; Tecchio, L B; Volkov, Y M

    2003-01-01

    A new type of a high temperature electron beam ion source (HTEBIS) with a working temperature up to 2500 deg. C was developed for production of single charge ions of practically all elements. Off-line tests and on-line experiments making use of the developed ion source coupled with uranium carbide targets of different density, have been carried out. The ionization efficiency measured for stable atoms of many elements varied in the interval of 1-6%. Using the HTEBIS, the yields and on-line production efficiency of neutron rich isotopes of Mn, Fe, Co, Cu, Rh, Pd, Ag, Cd, In, Sn and isotopes of heavy elements Pb, Bi, Po and some others have been determined. The revealed confinement effect of the ions produced in the narrow electron beam inside a hot ion source cavity has been discussed.

  13. Evaluation of the effect of increasing dietary vitamin E in combination with different fat sources on performance, humoral immune responses and antioxidant status of weaned pigs

    DEFF Research Database (Denmark)

    Lauridsen, Charlotte

    2010-01-01

    involved a total of 180 pigs of 20 litters. Nine pigs of each litter were allotted to 9 dietary treatments in a 3 × 3 factorial arrangement of treatments in a randomized complete block design, which was conducted in 20 replicates. The 9 experimental groups were fed 50 g/kg diet of tallow, sunflower oil......This study investigated the influence of different fat sources and vitamin E supplementation on performance, humoral immune responses, plasma biochemical responses, mucosal fatty acid profile, and α-tocopherol status in serum and intestine of pigs after weaning (days 28-56 of age). The experiment...... responses, concentration of triglyceride and cholesterol in plasma, and fatty acid composition of mucosal samples. Vitamin E supplementation increased the α-tocopherol status of pigs 14 days after weaning, and a dietary concentration of 150 mg vitamin E/kg diet (at the present fat level of 50 g/kg diet...

  14. Uniform H(-) ion beam extraction in a large negative ion source with a tent-shaped magnetic filter.

    Science.gov (United States)

    Tobari, H; Hanada, M; Kashiwagi, M; Taniguchi, M; Umeda, N; Watanabe, K; Inoue, T; Sakamoto, K; Takado, N

    2008-02-01

    Based on previous studies on the spatial uniformity of the negative ion beam, the external magnetic filter was replaced to a novel tent-shaped magnetic filter in the JAEA 10 A negative ion source. The line-cusp field configuration on the source chamber was also changed to form a symmetric magnetic field like many of positive ion sources aiming at high proton yield. This magnetic field configuration allows fast electrons emitted from filament cathodes to rotate azimuthally inside the source chamber. The source configuration thus prevents localization of fast electrons due to their B x grad B drift in the filter field. As a result, the H(-) ion beam profile extracted from a wide region of 340 x 170 mm(2) showed reduction of standard deviation from 16% in the original to 7.9% with the tent filter. The negative ion source with the tent filter satisfied the requirement of the beam uniformity for a large negative ion source in the ITER neutral beam injection.

  15. Studies on the positive hydrogen ion production from a small multicusp source

    Energy Technology Data Exchange (ETDEWEB)

    Olivo, M.; Mariani, E. (Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland)); Leung, K.N. (Lawrence Berkeley Laboratory (LBL), University of California, Berkeley, California 94720 (United States))

    1994-04-01

    An rf driven ion source has been developed and tested at LBL for positive hydrogen ion production. Studies of this new source on ion species and current densities for a dc arc discharge are made in the 60-kV PSI ion source test stand and the results compared with those obtained using the rf discharge. This source, using both discharge modes, will be installed in the PSI Cockcroft--Walton preinjector to increase the 870-keV dc proton beam intensity from the present 8--10 mA operation to about 25 mA.

  16. Predictive ion source control using artificial neural network for RFT-30 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Young Bae, E-mail: ybkong@kaeri.re.kr; Hur, Min Goo; Lee, Eun Je; Park, Jeong Hoon; Park, Yong Dae; Yang, Seung Dae

    2016-01-11

    An RFT-30 cyclotron is a 30 MeV proton accelerator for radioisotope production and fundamental research. The ion source of the RFT-30 cyclotron creates plasma from hydrogen gas and transports an ion beam into the center region of the cyclotron. Ion source control is used to search source parameters for best quality of the ion beam. Ion source control in a real system is a difficult and time consuming task, and the operator should search the source parameters by manipulating the cyclotron directly. In this paper, we propose an artificial neural network based predictive control approach for the RFT-30 ion source. The proposed approach constructs the ion source model by using an artificial neural network and finds the optimized parameters with the simulated annealing algorithm. To analyze the performance of the proposed approach, we evaluated the simulations with the experimental data of the ion source. The performance results show that the proposed approach can provide an efficient way to analyze and control the ion source of the RFT-30 cyclotron.

  17. Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2008-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has recently been developed and installed in order to extend the variety and the intensity of ions at the RCNP coupled cyclotron facility. Production of several ions such as O, N, Ar, Kr, etc., is now under development and some of them have already been used for user experiments. For example, highly charged heavy ion beams like (86)Kr(21+,23+) and intense (16)O(5+,6+) and (15)N(6+) ion beams have been provided for experiments. The metal ion from volatile compounds method for boron ions has been developed as well.

  18. Dynamics of Ion Beam Charge Neutralization by Ferroelectric Plasma Sources

    Science.gov (United States)

    Stepanov, Anton D.; Gilson, Erik P.; Grisham, Larry R.; Kaganovich, Igor D.; Davidson, Ronald C.; Ji, Qing; Persaud, Arun; Seidl, Peter A.; Schenkel, Thomas

    2016-10-01

    Ferroelectric Plasma Sources (FEPSs) can generate plasma that provides effective space-charge neutralization of intense high-perveance ion beams. Here we present experimental results on charge neutralization of a high-perveance 38 keV Ar+ beam by a FEPS plasma. By comparing the measured beam radius with the envelope model for space-charge expansion, it is shown that a charge neutralization fraction of 98% is attainable. The transverse electrostatic potential of the ion beam is reduced from 15 V before neutralization to 0.3 V, implying that the energy of the neutralizing electrons is below 0.3 eV. Near-complete charge neutralization is established 5 μs after the driving pulse is applied to the FEPS, and can last for 35 μs. It is argued that the duration of neutralization is much longer than a reasonable lifetime of the plasma produced in the sub- μs surface discharge. Measurements of current flow in the driving circuit of the FEPS suggest that plasma can be generated for tens of μs after the high voltage pulse is applied. This is confirmed by fast photography of the plasma in the 1-meter long FEPS on NDCX-II, where effective charge neutralization of the beam was achieved with the optimized FEPS timing. This work was supported by the Office of Science of the US Department of Energy under contracts DE-AC0209CH11466 (PPPL) and DE-AC0205CH11231 (LBNL).

  19. Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)

    CERN Document Server

    Rothe, S; Crepieux, B; Day Goodacre, T; Fedosseev, V N; Giles, T; Marsh, B A; Ramos, J P; Rossel, R E

    2016-01-01

    We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicates its capability to survive the thermal stress expected during operation in an ISOLDE target unit. Finally, we introduce fast ion beam switching at a rate of 10 kHz using the ISOLDE ion beam switchyard as a new concept for ion beam distribution and conclude by highlighting the potential applications of this ion beam multiplexing te...

  20. Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)

    Energy Technology Data Exchange (ETDEWEB)

    Rothe, S., E-mail: sebastian.rothe@cern.ch [CERN, Geneva (Switzerland); Catherall, R.; Crepieux, B. [CERN, Geneva (Switzerland); Day Goodacre, T. [CERN, Geneva (Switzerland); School of Physics and Astronomy, The University of Manchester, Manchester (United Kingdom); Fedosseev, V.N.; Giles, T.; Marsh, B.A. [CERN, Geneva (Switzerland); Ramos, J.P. [CERN, Geneva (Switzerland); Laboratory of Powder Technology, EPFL, Lausanne (Switzerland); Rossel, R.E. [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Faculty of Design, Computer Science and Media, Hochschule RheinMain, Wiesbaden (Germany)

    2016-06-01

    We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicates its capability to survive the thermal stress expected during operation in an ISOLDE target unit. Finally, we introduce fast ion beam switching at a rate of 10 kHz using the ISOLDE ion beam switchyard as a new concept for ion beam distribution and conclude by highlighting the potential applications of this ion beam multiplexing technique.