WorldWideScience

Sample records for phantom parent groups

  1. Fuzzy classification of phantom parent groups in an animal model

    Directory of Open Access Journals (Sweden)

    Fikse Freddy

    2009-09-01

    Full Text Available Abstract Background Genetic evaluation models often include genetic groups to account for unequal genetic level of animals with unknown parentage. The definition of phantom parent groups usually includes a time component (e.g. years. Combining several time periods to ensure sufficiently large groups may create problems since all phantom parents in a group are considered contemporaries. Methods To avoid the downside of such distinct classification, a fuzzy logic approach is suggested. A phantom parent can be assigned to several genetic groups, with proportions between zero and one that sum to one. Rules were presented for assigning coefficients to the inverse of the relationship matrix for fuzzy-classified genetic groups. This approach was illustrated with simulated data from ten generations of mass selection. Observations and pedigree records were randomly deleted. Phantom parent groups were defined on the basis of gender and generation number. In one scenario, uncertainty about generation of birth was simulated for some animals with unknown parents. In the distinct classification, one of the two possible generations of birth was randomly chosen to assign phantom parents to genetic groups for animals with simulated uncertainty, whereas the phantom parents were assigned to both possible genetic groups in the fuzzy classification. Results The empirical prediction error variance (PEV was somewhat lower for fuzzy-classified genetic groups. The ranking of animals with unknown parents was more correct and less variable across replicates in comparison with distinct genetic groups. In another scenario, each phantom parent was assigned to three groups, one pertaining to its gender, and two pertaining to the first and last generation, with proportion depending on the (true generation of birth. Due to the lower number of groups, the empirical PEV of breeding values was smaller when genetic groups were fuzzy-classified. Conclusion Fuzzy

  2. Group Work with Abusive Parents.

    Science.gov (United States)

    Kruger, Lois; And Others

    1979-01-01

    Social work students conclude from an experience that parents can consider alternative means of disciplining children when they participate in a parent group that is comfortable and when attendance is promoted by provision of tangible services. Parents achieved increased sense of self-worth and learned appropriate ways of expressing anger. (Author)

  3. Group therapy for selective mutism - a parents' and children's treatment group.

    Science.gov (United States)

    Sharkey, Louise; Mc Nicholas, Fiona; Barry, Edwina; Begley, Maire; Ahern, Sinead

    2008-12-01

    To evaluate the feasibility and effectiveness of group therapy for children with selective mutism and their parents. Five children (mean age 6.1 years) with a diagnosis of selective mutism were administered group therapy over an 8-week period. Parents simultaneously attended a second group, aimed at providing education and advice on managing selective mutism in everyday situations, and in the school environment. At post-treatment, all children increased their level of confident speaking in school, clinic and community settings. Parents indicated a reduction in their own anxiety levels, from pre- to post-treatment on self-rating scales. Findings support the feasibility and effectiveness of group therapy for children with selective mutism and their parents.

  4. Parents' experiences of parental groups in Swedish child health-care: Do they get what they want?

    Science.gov (United States)

    Lefèvre, Åsa; Lundqvist, Pia; Drevenhorn, Eva; Hallström, Inger

    2016-03-01

    Almost all parents in Sweden are invited to parental groups organized by the child health service (CHS) during their child's first year, but only 40% chose to attend. The aim of this study was to describe parents' experiences of participating in these parental groups. A total of 143 parents from 71 different parental groups at 27 child health-care (CHC) centres in one Swedish county completed an online questionnaire. A majority of the parents found the parental groups to be meaningful and more than 60% met someone in the group who they socialized with outside the meetings. Parents wanted a greater focus on child-related community information, existential questions, relationships and parenting in general. Group leadership seems to be of significance to how parents in a group connect and whether the parental role is affected. Making CHC nurses more aware of the topics parents desire could help them meet parents' needs. Education and training in group dynamics and group leadership could be of value in further improving the high-quality service CHC nurses already offer parents. More knowledge is needed about what would attract those parents who do not participate. © The Author(s) 2014.

  5. Parents' Networking Strategies: Participation of Formal and Informal Parent Groups in School Activities and Decisions

    Science.gov (United States)

    Wanat, Carolyn L.

    2010-01-01

    This case study examined parent groups' involvement in school activities and their participation in decision making. Research questions included the following: (1) What is the nature of parent groups in schools? (2) What activities and issues gain parent groups' attention and participation? (3) How do parent groups communicate concerns about…

  6. Guia para Padres: Acceso a los Grupos de Padres (Accessing Parent Groups: A Parent's Guide).

    Science.gov (United States)

    Interstate Research Associates, McLean, VA.

    This guide, in Spanish, notes the value of parent groups for parents of children with disabilities, as they offer parents a place and a means to share information, give and receive emotional support, and work as a team to address common concerns. Typical activities of a parent group are listed, and ways of identifying parent groups that exist…

  7. Engaging Urban Parents of Early Adolescents in Parenting Interventions: Home Visits vs. Group Sessions.

    Science.gov (United States)

    Finigan-Carr, Nadine M; Copeland-Linder, Nikeea; Haynie, Denise L; Cheng, Tina L

    2014-01-01

    Interventions targeting parents of young children have shown effectiveness, but research is lacking about best practices for engaging parents of early adolescents. Low levels of enrollment and attendance in parenting interventions present major problems for researchers and clinicians. Effective and efficient ways to engage and collaborate with parents to strengthen parenting practices and to promote healthy development of early adolescents are needed. This exploratory mixed methods study examined the feasibility of three methods of engaging parents in positive parenting activities. Participants were parents of youth ages 11-13 enrolled in three urban, public middle schools in neighborhoods characterized by high rates of community violence. Families ( N = 144) were randomized into one of three interventions: six home sessions, two home sessions followed by four group sessions, or six group sessions. The majority of parents were single, non-Hispanic, African American mothers. Urban parents of middle school students were more likely to participate in home visits than in group sessions; offering a combination did not increase participation in the group sessions. As only 34% of those who consented participated in the intervention, qualitative data were examined to explain the reasons for non-participation.

  8. Managing parental groups: personal impact of a group leadership course for child healthcare nurses.

    Science.gov (United States)

    Lefèvre, Åsa; Lundqvist, Pia; Drevenhorn, Eva; Hallström, Inger

    2017-02-01

    To investigate the experience and personal impact of a group leadership course for child healthcare nurses. During their child's first year, all parents in Sweden are invited to participate in parental groups within the child health service; however, only 49% choose to participate. Despite extensive experience, child healthcare nurses find managing parental groups challenging and express a need for training in group dynamics and group leadership. The study was designed as a controlled study with a pretest/post-test design where the participants form their own control group. A group leadership course was given to 56 child healthcare nurses and evaluated in a pre- and postintervention questionnaire, a course evaluation and an interview with the course leaders. The child healthcare nurses felt their group leadership skills were strengthened and the majority (96%) felt that the course had changed their way of leading parental groups. They felt that the group leader role had been clarified and that they had obtained several new tools to use in their groups. Clarifying the role of group leader and adding knowledge about group leadership and dynamics seems to have increased the self-confidence for child healthcare nurses in group leadership. Improved confidence in group management might motivate the child healthcare nurses to further develop parental groups to attract the parents who currently choose not to participate. © 2016 John Wiley & Sons Ltd.

  9. The Parenting Questionnaire: An Inventory for Assessing Outcomes of Adlerian Parent Groups.

    Science.gov (United States)

    Tiffany, Jeanne; Tollefson, Nona

    This study field tests and evaluates the Parenting Questionnaire, an instrument designed to assess parental attitudes and behavior, based on the child-raising theories of Dreikurs and Dinkmeyer and the Adlerian model for parent study groups. Dreikurs and Adler stress the purposive nature of children's behavior or misbehavior, and teach parents to…

  10. Phantom motor execution facilitated by machine learning and augmented reality as treatment for phantom limb pain: a single group, clinical trial in patients with chronic intractable phantom limb pain.

    Science.gov (United States)

    Ortiz-Catalan, Max; Guðmundsdóttir, Rannveig A; Kristoffersen, Morten B; Zepeda-Echavarria, Alejandra; Caine-Winterberger, Kerstin; Kulbacka-Ortiz, Katarzyna; Widehammar, Cathrine; Eriksson, Karin; Stockselius, Anita; Ragnö, Christina; Pihlar, Zdenka; Burger, Helena; Hermansson, Liselotte

    2016-12-10

    Phantom limb pain is a debilitating condition for which no effective treatment has been found. We hypothesised that re-engagement of central and peripheral circuitry involved in motor execution could reduce phantom limb pain via competitive plasticity and reversal of cortical reorganisation. Patients with upper limb amputation and known chronic intractable phantom limb pain were recruited at three clinics in Sweden and one in Slovenia. Patients received 12 sessions of phantom motor execution using machine learning, augmented and virtual reality, and serious gaming. Changes in intensity, frequency, duration, quality, and intrusion of phantom limb pain were assessed by the use of the numeric rating scale, the pain rating index, the weighted pain distribution scale, and a study-specific frequency scale before each session and at follow-up interviews 1, 3, and 6 months after the last session. Changes in medication and prostheses were also monitored. Results are reported using descriptive statistics and analysed by non-parametric tests. The trial is registered at ClinicalTrials.gov, number NCT02281539. Between Sept 15, 2014, and April 10, 2015, 14 patients with intractable chronic phantom limb pain, for whom conventional treatments failed, were enrolled. After 12 sessions, patients showed statistically and clinically significant improvements in all metrics of phantom limb pain. Phantom limb pain decreased from pre-treatment to the last treatment session by 47% (SD 39; absolute mean change 1·0 [0·8]; p=0·001) for weighted pain distribution, 32% (38; absolute mean change 1·6 [1·8]; p=0·007) for the numeric rating scale, and 51% (33; absolute mean change 9·6 [8·1]; p=0·0001) for the pain rating index. The numeric rating scale score for intrusion of phantom limb pain in activities of daily living and sleep was reduced by 43% (SD 37; absolute mean change 2·4 [2·3]; p=0·004) and 61% (39; absolute mean change 2·3 [1·8]; p=0·001), respectively. Two of four

  11. The impact of group training about parenting styles on maternal attitudes toward parenting styles.

    Science.gov (United States)

    Zandiyeh, Zahra; Zare, Elaheh; Hedayati, Batool

    2015-01-01

    Parenting style is one of the most important and effective factors in training and growth of children and adolescents and the method that parents communicate with their children is an effective factor on family contact models. The aim of this study was to determine the impact of group training about parenting styles on maternal attitudes that were admitted to Isfahan Imam Ali (AS) health care center in 2013. This was an experimental study, which was conducted on a random sample of 25 mothers referred to this health care center. They were divided into two groups (experimental and control). The experimental group received five sessions of group training, and the control group received a booklet about parenting styles. The used tool in this study was the Bamerind Parenting Style Questionnaire that was completed by the mothers before and after the intervention and finally, their obtained scores were compared with each other. The results of the present study showed that the mean score of attitude toward easy-going style in test group was less than the control group after intervention (P = 0.045). The mean score of attitude toward authoritative style in the experimental group was less than control group after intervention (P = 0.037) and the mean score of attitude toward authoritative style in the experimental group was more than the control group after intervention (P = 0.011). Group training can be an appropriate method in changing maternal attitudes toward parenting styles.

  12. Managing parental groups: personal impact of a group leadership course for child healthcare nurses.

    OpenAIRE

    Lefevre, Åsa; Lundqvist, Pia; Drevenhorn, Eva; Hallström, Inger

    2017-01-01

    AIMS AND OBJECTIVES: To investigate the experience and personal impact of a group leadership course for child healthcare nurses.BACKGROUND: During their child's first year, all parents in Sweden are invited to participate in parental groups within the child health service; however, only 49% choose to participate. Despite extensive experience, child healthcare nurses find managing parental groups challenging and express a need for training in group dynamics and group leadership.DESIGN: The stu...

  13. Group treatment for parents of the adult mentally ill.

    Science.gov (United States)

    McLean, C S; Greer, K; Scott, J; Beck, J C

    1982-07-01

    Support and education groups for the families of the mentally ill have been in existence for at least 20 years. The authors describe a group treatment program established in 1979 for parents of chronically mentally ill individuals living in the community. The goal was to help parents become less overprotective, critical, and hostile so that clients would relapse less frequently and improve their social functioning during their time in the community. The groups provided parents with information and support. Some of the results of the groups include the implementation of new hospital procedures, more effective parenting, and a parent-initiated alliance on behalf of the mentally ill in the locality.

  14. Group psychotherapy for parents of patients with schizophrenia.

    Science.gov (United States)

    Gruber, Ema N; Kajević, Milka; Agius, Mark; Martić-Biocina, Sanja

    2006-11-01

    During a four-month period, the authors provided group psychotherapy combining psychodynamic, supportive and psycho-educational approaches. The aim was to investigate whether this approach would enable parents of patients with schizophrenia to re-establish their psychic balance and the balance of the whole family system by reducing high expressed emotion. The following tools were administered: a socio-cultural questionnaire, MMPI and PIE psychological tests and two questionnaires for group evaluation. The socio-cultural questionnaire showed that the group of parents is heterogeneous. MMPI profiles showed truthful answers and well organized thinking; there were no psychopathological symptoms. The PIE test showed increased dimensions of sociability and trust. The dimensions of fear, sorrow and anger were decreased. Combinations of primary emotions (marked sociability and high self-protection) show that the parents are cautious, responsible and tend to feel guilt. The parents evaluated the group work as interesting and helpful and the group as a place where the parents can overcome the stigma of the disease that affects them, get information, find help and friends and find a way out of their social isolation. This combined approach changes the emotional profile of parents, reduces high expressed emotions (fear, sorrow and anger) in parents and helps re-establish their psychic balance and the balance of the whole family system.

  15. SELF-HELP GROUPS FOR PARENTS WITH MENTALLY RETARDED CHILDREN

    Directory of Open Access Journals (Sweden)

    Vaska STANCHEVA-POPKOSTADINOVA

    1997-09-01

    Full Text Available This presentation concerns a group for parents of mentally retarded children.A group of these parents receives professional help and environmental support. The parents are encouraged to assume responsibility in the everyday life educational process of their children.As Baker / 1980 / states: “ If parents cope better on daily basis with the child who has mental retardation, not only the child but also the parents would benefit”.Taking part in the group gave the parents:· the opportunity to meet other parents with the same children;· to talk to other parents and feel less isolated;· to share information and experiences, skills and ideas;· the opportunity to listen to the needs and problems of other parents;· to change the ways of working to meet the child’s needs;· share information about the possibilities of education and services;· parents are encouraged to meet together to support one another;· parents need a special approach to many problems existing in their families.· the education in the group puts the beginning of the work with the parents.The idea is to gather the efforts of specialists from different fields and to establish multi-disciplinary group aiming to work with the parents and create a good collaboration and partnership between them in order to improve the living conditions and services to the retarded persons.This paper reports on the development, evaluation and dissemination of the program for education of parents with mentally retarded children. At the Symposium we will be able to present the results of the effectiveness of the education.

  16. Examining Parents' Preferences for Group and Individual Parent Training for Children with ADHD Symptoms.

    Science.gov (United States)

    Wymbs, Frances A; Cunningham, Charles E; Chen, Yvonne; Rimas, Heather M; Deal, Ken; Waschbusch, Daniel A; Pelham, William E

    2016-01-01

    Parent training (PT) programs have been found to reduce some behavioral impairment associated with children's attention deficit hyperactivity disorder (ADHD) as well as improve parenting competence, but poor uptake and participation by parents are formidable barriers that affect service effectiveness. We used a discrete-choice experiment (DCE) to examine how parent preferences for treatment format (i.e., group vs. individual) might influence their participation in PT. Participants were 445 parents seeking mental health services for children with elevated symptoms of ADHD in Ontario, Canada. Parents completed a DCE composed of 30 choice tasks used to gauge PT format preference. Results showed that 58.7% of parents preferred individual PT; these parents were most interested in interventions that would make them feel more informed about their child's problems and in understanding-as opposed to solving-their child's problems. A minority of parents (19.4%) preferred group PT; these parents were most interested in active, skill-building services that would help them solve their child's problems. About one fifth of parents (21.9%) preferred the Minimal Information alternative (i.e., receiving neither individual or group PT); these parents reported the highest levels of depression and the most severe mental health problems in their child. Results highlight the importance of considering parent preferences for format and suggest that alternative formats to standard PT should be considered for multiply stressed families.

  17. Barriers to first time parent groups: A qualitative descriptive study.

    Science.gov (United States)

    Barrett, Norma; Hanna, Lisa; Fitzpatrick, Owen Vincent

    2018-06-19

    First-time parents' groups are offered to new parents in Australia to support their transition to parenthood. Not all parents avail of the service, some cease attendance, and fathers are under-represented. In the present descriptive, qualitative study, we examined first-time mothers' perspectives on the barriers to parental participation in the groups. Semi-structured interviews were conducted with a sample of eight first-time mothers in a regional city in Victoria, Australia. Interviews revealed groups were perceived as sites strongly reinforcing traditional social norms of parenting. From this central theme, six gendered subthemes emerged as barriers to attendance. Barriers to mothers included non-normative mothering narratives, such as experiencing stillbirth or having a disabled child, perceived dissonance in parenting ethos, and group size. Barriers to fathers, as perceived by mothers, included groups as female spaces, dads as a minority, and female gatekeeping. A multi-faceted approach is required to change the common perception that groups are for mothers only. Groups need to be more inclusive of different parenting experiences and philosophies. Segregated groups might better address the needs of both parents. Further research is required to capture fathers' perspectives. © 2018 John Wiley & Sons Australia, Ltd.

  18. Phantom cosmologies and fermions

    International Nuclear Information System (INIS)

    Chimento, Luis P; Forte, Monica; Devecchi, Fernando P; Kremer, Gilberto M

    2008-01-01

    Form invariance transformations can be used for constructing phantom cosmologies starting with conventional cosmological models. In this work we reconsider the scalar field case and extend the discussion to fermionic fields, where the 'phantomization' process exhibits a new class of possible accelerated regimes. As an application we analyze the cosmological constant group for a fermionic seed fluid

  19. Parent Group Education to ENABLE “Barrio” Parents

    Directory of Open Access Journals (Sweden)

    Herman Curiel

    2014-04-01

    Full Text Available This paper describes a 1960s “War on Poverty” parent group education program that brought together three national private voluntary agencies with federal funding by the Office of Economic Opportunity (OEO. Project ENABLE (Education Neighborhood Action for a Better Living Environment sought to direct professional efforts to help/empower the poor and societal members of ethnic minority groups. Group education as a preventive modality was used to strengthen parents’ problem solving skills in their roles both as parents and as community leaders. The author describes his group leadership role together with that of the indigenous case aides who helped direct/enable the collective power of a group of poor Spanish speaking Mexican origin families living in barrios (neighborhoods of a major metropolitan southern city. Project ENABLE embraced a strengths-based perspective characteristic of social work’s historical empowerment traditions. Despite its brief existence, Project ENABLE functioned as a demonstration program in 62 communities across the United States. Ironically, its prevention focus and demonstration nature served to undermine its ability to compete with other OEO initiatives like Head Start and job training programs. The author cites a combination of historical and logistic factors that contributed to the short life and ultimate demise of a once promising outreach program.

  20. Computer-mediated support group intervention for parents.

    Science.gov (United States)

    Bragadóttir, Helga

    2008-01-01

    The purpose of this study was to evaluate the feasibility of a computer-mediated support group (CMSG) intervention for parents whose children had been diagnosed with cancer. An evaluative one-group, before-and-after research design. A CMSG, an unstructured listserve group where participants used their E-mail for communication, was conducted over a 4-month period. Participation in the CMSG was offered to parents in Iceland whose children had completed cancer treatment in the past 5 years. Outcome measures were done: before the intervention (Time 1), after 2 months of intervention (Time 2) and after 4 months of intervention (Time 3) when the project ended. Measures included: demographic and background variables; health related vulnerability factors of parents: anxiety, depression, somatization, and stress; perceived mutual support; and use of the CMSG. Data were collected from November 2002 to June 2003. Twenty-one of 58 eligible parents participated in the study, with 71% retention rate for both post-tests. Mothers' depression decreased significantly from Time 2 to Time 3 (pcomputer technology for support is particularly useful for dispersed populations and groups that have restrictions on their time. Computer-mediated support groups have been shown to be a valuable addition to, or substitute for, a traditional face-to-face mutual support group and might suit both genders equally.

  1. Parent-only Group Cognitive Behavioral Intervention for Children with Anxiety Disorders: A Control Group Study.

    Science.gov (United States)

    Salari, Elham; Shahrivar, Zahra; Mahmoudi-Gharaei, Javad; Shirazi, Elham; Sepasi, Mitra

    2018-04-01

    Parents play an important role in development and continuation of anxiety disorders in children. Yet the evidence on parent contribution in cognitive behavioral therapy (CBT) for childhood anxiety is limited. This open randomized trial examined the effectiveness of a parent-directed group CBT to manage children with anxiety disorders. Parents of 42 children aged 6-12 with primary anxiety disorders were allocated to a six, two-hour weekly intervention and a wait-list (WL) control. The Revised Children's Manifest Anxiety, Children's Depression Inventory, Strengths and Difficulties Questionnaire-Home Version, Depression-Anxiety-Stress Scale, Children Global Assessment Scale, and Global Relational Assessment of Functioning were used to assess children's and parents' functioning and emotional symptoms. Parents completed consumer satisfaction questionnaire. Parents in the CBT group reported significant improvement in their depressive symptoms (p=0.006) and the family functioning (p=0.04), as well as reduction in children's emotional symptoms (p=0.007). Clinician rating of children's functioning showed significant improvement in the CBT group(p=0.001). There was no significant difference in children rating of their anxiety within groups from pre- to post-intervention. Parents were satisfied mostly with the intervention. A brief parent-only CBT based intervention can be effective in the management of childhood anxiety.

  2. A model parent group for enhancing aggressive children's social competence in Taiwan.

    Science.gov (United States)

    Li, Ming-Hui

    2009-07-01

    This paper presents a semi-structured psychoeducational model of group work for parents of aggressive children based on concepts of co-parenting and bidirectionality. The group was developed for enhancing five Taiwanese aggressive children's social competence by promoting positive interactions within family. Topics covered in the group included identifying parenting styles, forming parental alliances, fostering parent-child mutual initiations/mutual compliances, establishing parent-child co-regulation, and responding to aggressive children's negative emotions. Pre- and post-group comparisons suggested the effectiveness of the group model.

  3. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...... questions regarding the experience of phantom shocks, date, time, and place. Twelve patients (9.4%) experienced a phantom shock, 7 in the intervention group and 5 in the control group (NS). Neither age, sex, quality of life nor perceived health at baseline was significantly related to the probability...

  4. Symbol phantoms

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Hongo, Syozo; Takeshita, Hiroshi

    1990-01-01

    We have developed Japanese phantoms in two procedures for computation of organ doses exposed to internal and/or external radiation sources. One method is to make mathematical phantoms on the basis of ORNL mathematical phantoms. Parameters to specify organs of Japanese mathematical phantom are determined by interpolations of the ORNL data, which define the organs of Caucasian males and females of various ages, i.e. new born, 1, 5, 10, 15 years and adult, with survey data for Japanese physiques. Another procedure is to build 'symbol phantoms' for the Japanese public. The concept and its method of the symbol phantom enables us to make a phantom for an individual when we have all of his transversal section images obtained by a medical imaging device like MRI, and thus we may achieve more realistic phantoms for Japanese public than the mathematical phantoms. Both studies are in progress in NIRS. (author)

  5. [Prevention groups for school-age children of mentally ill parents ("Auryn Groups")].

    Science.gov (United States)

    Dierks, H

    2001-09-01

    Children of psychiatrically ill parents have a high risk themselves to develop a psychiatric illness in adulthood. Prevention aims at strengthening the resilience of these children and reducing psychosocial risk factors. This article found and describes a theoretical concept of prevention groups for children in schoolage (7-16 years) whose parents are psychiatrically ill. First practical experiences are depicted. The Hamburgian model of prevention works with closed and temporary limited groups of children as well as with the parents. It is based on supporting the children's existing coping strategies and the children are encouraged to exchange their individual experiences of the relationships within their families. One conclusion was, that the main thematic emphasis varied considerably depending on the age of the children.

  6. Balloon sheaths for gastrointestinal guidance and access: a preliminary phantom study

    International Nuclear Information System (INIS)

    He, Xu; Shin, Ji Hoon; Kim, Hyo Cheol; Woo, Cheol Woong; Woo, Sung Ha; Choi, Won Chan; Kim, Jong Gyu; Lim, Jin Oh; Kim, Tae Hyung; Yoon, Chang Jin; Song, Ho Young; Kang, Wee Chang

    2005-01-01

    We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group II was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (ρ < 0.001). A significant difference was also found between group III and IV for both phantoms (ρ < 0.001). The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body

  7. A Handbook for Helping Parents "Group."

    Science.gov (United States)

    Bell, Catherine; And Others

    A home based project serving special needs children 0 to 5 years old in a rural area developed a mothers' group designed to increase parents' self esteem, decrease their isolation, and provide more information about their child's development. An introductory section outlines general assumptions of the group and describes a sequence of activities…

  8. From thought to action: young parents' reasons for participation in parenting support groups at child welfare centers.

    Science.gov (United States)

    Hjelte, Jan; Sjöberg, Magdalena; Westerberg, Kristina; Hyvönen, Ulf

    2015-01-01

    In this article the focus is on young parents' engagement process in relation to participation in parenting support groups carried out at child welfare centers. This qualitative study focuses not only on young parents' reasons for participating or not participating in parenting support groups during different phases in their engagement process, but also on examining the circumstances that may contribute to such changes. The results show that these reasons can be divided into four categories: the staff, other participants, the social network, and practical circumstances. It also appears that these reasons change between different phases of their engagement process. Primarily three different circumstances contributed to variation in parents' reasons: difficulty in predicting the value of participation, increased closeness in relationships with staff and other parents, and the specific life phase in which young parents find themselves. The results have important implications for policy makers and practitioners in their work in formulating and updating parenting support; they also indicate what may be important to focus on in the recruitment of young parents, and also what may be crucial in regard to them completing their engagement in parent support groups.

  9. Effectiveness of Group Positive Parenting Program (Triple P) in Changing Child Behavior, Parenting Style, and Parental Adjustment: An Intervention Study in Japan

    Science.gov (United States)

    Fujiwara, Takeo; Kato, Noriko; Sanders, Matthew R.

    2011-01-01

    The purpose of this study is to investigate the effectiveness of a group-based family intervention program known as the Group Positive Parenting Program (Triple P), with families in Japan. Reductions in children's behavioral problems, changes in dysfunctional parenting practices, and affects on parenting adjustment were examined. Participants of…

  10. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (original ICRP reference phantoms, it is believed that the polygon-surface version of ICRP reference phantoms properly developed will not only provide the same or similar dose values (say, difference <5 or 10%) for highly penetrating radiations, but also provide correct dose values for the weakly penetrating

  11. Separation and Relating in a Parent-Toddler Group Setting

    Science.gov (United States)

    Navridi, Evanthia; Navridis, Klimis; Midgley, Nick

    2012-01-01

    Parent-toddler groups constitute a primary intervention programme whose target is to support and encourage the parent-toddler relationship. Toddlerhood is a developmental period when major, crucial changes take place regarding how children function, as well as their relationship to their parents (especially to their mother). The present paper…

  12. Conversion of ICRP male reference phantom to polygon-surface phantom

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-01-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  13. Parents' experiences of being in the Solihull Approach parenting group, 'Understanding Your Child's Behaviour': an interpretative phenomenological analysis.

    Science.gov (United States)

    Vella, L R; Butterworth, R E; Johnson, R; Law, G Urquhart

    2015-11-01

    Empirical evidence suggests that the Solihull Approach parenting group, 'Understanding Your Child's Behaviour' (UYCB), can improve child behaviour and parental well-being. However, little is known about parents' in-depth experience of participating in the UYCB programme. This study provides an in-depth qualitative evaluation of UYCB, focussing on possible moderating factors and mechanisms of change that may inform programme development. Ten parents (eight mothers and two fathers), recruited from seven UYCB groups across two locations, were interviewed within 7 weeks of completing the group and again 10 months later. Data were analysed using interpretative phenomenological analysis. Four themes were identified: 'Two Tiers of Satisfaction', 'Development as a Parent', 'Improved Self-belief' and 'The "Matthew Effect"'. In summary, the majority of parents were immensely satisfied at both completion and follow-up: they valued an experience of containment and social support and perceived improvement in specific child difficulties, their experience of parenting, their confidence and their coping. Most parents appeared to have developed more reflective and empathic parenting styles, with self-reported improved behaviour management. Theoretical material was well received, although some struggled with technical language. Positive outcomes appeared to be maintained, even reinforced, at follow-up, and were associated with having few initial child difficulties, perceiving improvement at completion and persevering with the recommendations. Two participants, whose children had the most severe difficulties, perceived deterioration and felt that the group was insufficient for their level of difficulties. Through in-depth analysis of parental experiences, UYCB appears to achieve its aims and communicate well its theoretical principles, although change may also occur through processes common to other group programmes (e.g. social support). Recommendations, stemming from the

  14. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT plans already planned on treatment planning system (TPS for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA. All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA and dose for each plan was measured by 0.13 cc ion chamber. The percentage (% variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA plans were as 0.65 (Standard deviation (SD: 0.38 with confidence limit (CL 1.39, 1.16 (SD: 0.61 with CL 2.36 and 2.40 (SD: 0.86 with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  

  15. Support Group for Parents Coping with Children with Type 1 Diabetes.

    Science.gov (United States)

    Pate, Tanja; Rutar, Miha; Battelino, Tadej; Drobnič Radobuljac, Maja; Bratina, Nataša

    2015-06-01

    Type 1 diabetes is one of the most common chronic diseases in childhood. Active parental involvement, parental support in the diabetes management and family functioning are associated with optimal diabetes management and glycemic control. The purpose of this study was to assess parental satisfaction with participation in the group and their perceptions of the impact of the intervention on living and coping with childrens T1D. A sample of 34 parents of children with T1D participated in this trend study. The participants' experience and satisfaction with support group was measured by a self- evaluation questionnaire, designed for the purpose of the present study. Quantitative data show that parents were overall satisfied with almost all measured items of the evaluation questionnaire (wellbeing in the group, feeling secure, experiencing new things, being able to talk and feeling being heard) during the 4-year period. However, parents from the second and third season, on average, found that the support group has better fulfilled their expectations than the parents from the first season (p = 0,010). The qualitative analysis of the participants' responses to the open-ended questions was underpinned by four themes: support when confronting the diagnosis, transformation of the family dynamics, me as a parent, exchange of experience and good practice and facing the world outside the family. The presented parent support group showed to be a promising supportive, therapeutic and psychoeducative space where parents could strengthen their role in the upbringing of their child with T1D.

  16. Food Parenting Measurement Issues: Working Group Consensus Report

    OpenAIRE

    Hughes, Sheryl O.; Frankel, Leslie A.; Beltran, Alicia; Hodges, Eric; Hoerr, Sharon; Lumeng, Julie; Tovar, Alison; Kremers, Stef

    2013-01-01

    Childhood obesity is a growing problem. As more researchers become involved in the study of parenting influences on childhood obesity, there appears to be a lack of agreement regarding the most important parenting constructs of interest, definitions of those constructs, and measurement of those constructs in a consistent manner across studies. This article aims to summarize findings from a working group that convened specifically to discuss measurement issues related to parental influences on...

  17. Parent and adolescent effects of a universal group program for the parenting of adolescents.

    Science.gov (United States)

    Chu, Joanna Ting Wai; Bullen, Pat; Farruggia, Susan P; Dittman, Cassandra K; Sanders, Matthew R

    2015-05-01

    There is growing support for the large-scale implementation of parenting programs for the prevention of child behavior disorders and child maltreatment in younger children. However, there is only limited evidence on the efficacy of parenting programs in modifying risk and protective factors relating to adolescent behavior problems. This study examined the efficacy of Group Teen Triple P (GTTP), an eight-session parenting program specifically designed for parents of young adolescents. Seventy-two families with adolescents aged between 12 and 15 years were randomly assigned to either GTTP (n = 35) or a care as usual (CAU) control condition (n = 37). Compared to CAU parents, parents who received GTTP reported significant improvements in parenting practices, parenting confidence, the quality of family relationships, and fewer adolescent problem behaviors at post-intervention. Several of the parent-reported effects were corroborated by reports from adolescents, including decreases in parent-adolescent conflict and increases in parental monitoring. Adolescents whose parents participated in GTTP also reported significantly fewer behavioral problems than adolescents in the CAU condition. Many of these improvements were maintained at 6-month follow-up.

  18. The Phantom Menace

    DEFF Research Database (Denmark)

    Vium, Christian

    2013-01-01

    as a phantom menace, which asserts itself through a form of omnipresent fear, nurtured by an inherent opaqueness. As this fundamental fear progressively permeates the nomadic landscape, it engenders a recasting of mobile strategies among the nomadic pastoralist groups who inhabit the interstitial desert spaces....

  19. A Software Phantom : Application in Digital Tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Lazos, D; Kolitsi, Z; Badea, C; Pallikarakis, N [Medical Physics Laboratory, School of Medicine, Univercity of Patras (Greece)

    1999-12-31

    A software phantom intended to be used in radiographic applications has been developed. The application was used for research in the field of Digital Tomosynthesis and specifically for studying tomographic noise removal methods. The application consists of a phantom design and a phantom imaging module. The radiation-matter interaction is based on the exponential relation of attenuation. Projections are formed by simulated irradiation with selectable geometrical parameters, source spectrum and detector response. Phantoms are defined either as sets containing certain geometrical objects or as groups of voxels. Comparison with real projections taken from a physical phantom with identical geometry and composition with the simulated one, showed good approximation with improved contrast due to the absence of scatter in the simulated projections. The software phantom proved to be a very useful tool for DTS investigations. Further development to include scatter is expected to expand the use of the application to more areas in radiological imaging research. (author) 4 refs., 3 figs

  20. A Software Phantom : Application in Digital Tomosynthesis

    International Nuclear Information System (INIS)

    Lazos, D.; Kolitsi, Z.; Badea, C.; Pallikarakis, N.

    1998-01-01

    A software phantom intended to be used in radiographic applications has been developed. The application was used for research in the field of Digital Tomosynthesis and specifically for studying tomographic noise removal methods. The application consists of a phantom design and a phantom imaging module. The radiation-matter interaction is based on the exponential relation of attenuation. Projections are formed by simulated irradiation with selectable geometrical parameters, source spectrum and detector response. Phantoms are defined either as sets containing certain geometrical objects or as groups of voxels. Comparison with real projections taken from a physical phantom with identical geometry and composition with the simulated one, showed good approximation with improved contrast due to the absence of scatter in the simulated projections. The software phantom proved to be a very useful tool for DTS investigations. Further development to include scatter is expected to expand the use of the application to more areas in radiological imaging research. (author)

  1. Parents, Peer Groups, and Other Socializing Influences.

    Science.gov (United States)

    Vandell, Deborah Lowe

    2000-01-01

    Critically examines three propositions of Harris' group socialization theory (1995, 1998) related to parents' long-term effects on children's psychological characteristics, peer groups' influences, and the nature of dyadic relationships. Maintains that available evidence is more consistent with a model of multiple socialization agents. Proposes a…

  2. With or without the group: Swedish midwives' and child healthcare nurses' experiences in leading parent education groups.

    Science.gov (United States)

    Forslund Frykedal, Karin; Rosander, Michael; Berlin, Anita; Barimani, Mia

    2016-12-01

    The aim of the study was to describe and to understand midwives' and child healthcare nurses' experiences of working with parent education groups through their descriptions of the role and what they find rewarding and challenging in that work. Data were collected through three open-ended questions from a web survey: 'How do you refer to your role when working in parent education?', 'What is the biggest challenge or difficulty for you when working in parent education?' and 'What is most rewarding when working in parent education?' The answers were analysed by using qualitative content analysis and correlation analysis. The results show that the midwives and child healthcare nurses either included or excluded the group when describing their role as leaders and their influence on parents. The same applies to what they found rewarding and what was difficult and challenging for them in working with the groups. Primarily, the leaders who excluded the group expressed a lack of competence on a professional level in managing groups and using the right teaching methods to process the knowledge content. One important question to deal with is how to best support midwives and nurses in child healthcare to be prepared for working with parent education groups. One obvious thing is to provide specialized training in an educational sense. An important aspect could also be providing supervision, individually or in groups. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Filipino students' reported parental socialization of academic achievement by socioeconomic group.

    Science.gov (United States)

    Bernardo, Allan B I

    2009-10-01

    Academic achievement of students differs by socioeconomic group. Parents' socialization of academic achievement in their children was explored in self-reports of 241 students from two socioeconomic status (SES) groups in the Philippines, using a scale developed by Bempechat, et al. Students in the upper SES group had higher achievement than their peers in the middle SES group, but had lower scores on most dimensions of parental socialization of academic achievement. Regression analyses indicate that reported parental attempts to encourage more effort to achieve was associated with lower achievement in students with upper SES.

  4. Toxicology Analysis of Tissue-Mimicking Phantom Made From Gelatin

    Science.gov (United States)

    Dolbashid, A. S.; Hamzah, N.; Zaman, W. S. W. K.; Mokhtar, M. S.

    2017-06-01

    Skin phantom mimics the biological skin tissues as it have the ability to respond to changes in its environment. The development of tissue-mimicking phantom could contributes towards the reduce usage of animal in cosmetics and pharmacokinetics. In this study, the skin phantoms made from gelatin were tested with four different commonly available cosmetic products to determine the toxicity of each substance. The four substances used were; mercury-based whitening face cream, carcinogenic liquid make-up foundation, paraben-based acne cleanser, and organic lip balm. Toxicity test were performed on all of the phantoms. For toxicity testing, topographical and electrophysiological changes of the phantoms were evaluated. The ability of each respective phantom to react with mild toxic substances and its electrical resistance were analysed in to determine the toxicity of all the phantom models. Four-electrode method along with custom made electrical impedance analyser was used to differentiate electrical resistance between intoxicated phantom and non-intoxicated phantom in this study. Electrical resistance values obtained from the phantom models were significantly higher than the control group. The result obtained suggests the phantom as a promising candidate to be used as alternative for toxicology testing in the future.

  5. Children of mentally ill parents-a pilot study of a group intervention program.

    Science.gov (United States)

    Christiansen, Hanna; Anding, Jana; Schrott, Bastian; Röhrle, Bernd

    2015-01-01

    The transgenerational transmission of mental disorders is one of the most prominent risk factors for the development of psychological disorders. Children of mentally ill parents are a vulnerable high risk group with overall impaired development and high rates of psychological disorders. To date there are only a few evidence based intervention programs for this group overall and hardly any in Germany. We translated the evidence based Family Talk Intervention by Beardslee (2009) and adapted it for groups. First results of this pilot study are presented. This investigation evaluates a preventive group intervention for children of mentally ill parents. In a quasi-experimental design three groups are compared: an intervention group (Family Talk Intervention group: n = 28), a Wait Control group (n = 9), and a control group of healthy children (n = 40). Mean age of children was 10.41 years and parental disorders were mostly depressive/affective disorders (n = 30), but a small number also presented with Attention-Deficit/Hyperactivity Disorder (n = 7). Children of mentally ill parents showed higher rates of internalizing/externalizing disorders before and after the intervention compared to children of parents with no disorders. Post intervention children's knowledge on mental disorders was significantly enhanced in the Family Talk Intervention group compared to the Wait Control group and the healthy control group. Parental ratings of externalizing symptoms in the children were reduced to normal levels after the intervention in the Family Talk Intervention group, but not in the Wait Control group. This pilot study of a group intervention for children of mentally ill parents highlights the importance of psycho-education on parental mental disorders for children. Long-term effects of children's enhanced knowledge about parental psychopathology need to be explored in future studies.

  6. The impact of group training about parenting styles on maternal attitudes toward parenting styles

    OpenAIRE

    Zandiyeh, Zahra; Zare, Elaheh; Hedayati, Batool

    2015-01-01

    Background: Parenting style is one of the most important and effective factors in training and growth of children and adolescents and the method that parents communicate with their children is an effective factor on family contact models. Objectives: The aim of this study was to determine the impact of group training about parenting styles on maternal attitudes that were admitted to Isfahan Imam Ali (AS) health care center in 2013. Materials and Methods: This was an experimental study, which ...

  7. "From resistance to challenge": child health service nurses experiences of how a course in group leadership affected their management of parental groups.

    Science.gov (United States)

    Lefèvre, Åsa; Lundqvist, Pia; Drevenhorn, Eva; Hallström, Inger

    2017-01-01

    All parents in Sweden are invited to child health service (CHS) parental groups, however only 49% of the families participate. The way the parental groups are managed has been shown to be of importance for how parents experience the support and CHS nurses describe feeling insecure when running the groups. Lack of facilitation, structure and leadership might jeopardise the potential benefit of such support groups. This study describes CHS nurses' experiences of how a course in group leadership affected the way they ran their parental groups. A course in group leadership given to 56 CHS nurses was evaluated in focus group interviews 5-8 months after the course. The nurses felt strengthened in their group leader role and changed their leadership methods. The management of parental groups was after the course perceived as an important work task and the nurses included time for planning, preparation and evaluation, which they felt improved their parental groups. Parental participation in the activities in the group had become a key issue and they used their new exercises and tools to increase this. They expressed feeling more confident and relaxed in their role as group leaders and felt that they could adapt their leadership to the needs of the parents. Specific training might strengthen the CHS nurses in their group leader role and give them new motivation to fulfil their work with parental groups.  Clinical Trials.gov ID: NCT02494128.

  8. Computer tomographic phantom

    International Nuclear Information System (INIS)

    Lonn, A.H.R.; Jacobsen, D.R.; Zech, D.J.

    1988-01-01

    A reference phantom for computer tomography employs a flexible member with means for urging the flexible member into contact along the curved surface of the lumbar region of a human patient. In one embodiment, the reference phantom is pre-curved in an arc greater than required. Pressure from the weight of a patient laying upon the reference phantom is effective for straightening out the curvature sufficiently to achieve substantial contact along the lumbar region. The curvature of the reference phantom may be additionally distorted by a resilient pad between the resilient phantom and a table for urging it into contact with the lumbar region. In a second embodiment of the invention, a flexible reference phantom is disposed in a slot in the top of a resilient cushion. The resilient cushion and reference phantom may be enclosed in a flexible container. A partially curved reference phantom in a slot in a resilient cushion is also contemplated. (author)

  9. Effectiveness of a Group-Based Program for Parents of Children with Dyslexia

    Science.gov (United States)

    Multhauf, Bettina; Buschmann, Anke; Soellner, Renate

    2016-01-01

    Parents of children with dyslexia experience more parenting stress and depressive symptoms than other parents. The purpose of this study was to evaluate the effects of a cognitive-behavioral group-based program for parents of dyslexic children on parenting stress levels, parent-child homework interactions and parental competencies. 39 children…

  10. Padres Maltratadores: Grupos de Autoayuda (Abusive Parents: Self-Help Groups).

    Science.gov (United States)

    Intebi, Irene V.; Groisman, Adriana E.

    1991-01-01

    Causes of child abuse by parents are discussed. A therapy program in Buenos Aires (Argentina) for abusive parents is described. The program utilizes self-help groups as part of the therapeutic plan and has found them to be promising. Referral, types of interactions with the groups, and short-, medium-, and long-term objectives are discussed. (BRM)

  11. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, I.V.B., E-mail: isabelle.lacerda@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Vieira, J.W. [Instituto Federal de Pernambuco (IFPE), Recife (Brazil); Oliveira, M.L.; Lima, F.R.A. [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PB), Recife (Brazil)

    2017-07-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  12. Dose distribution in organs: patient-specific phantoms versus reference phantoms

    International Nuclear Information System (INIS)

    Lacerda, I.V.B.; Vieira, J.W.; Oliveira, M.L.; Lima, F.R.A.

    2017-01-01

    Discrepancies between ICRP phantoms and real patients lead to disparities on patient-dose estimations. This paper aims to compare distribution of dose in organs of male/female specific-phantoms and ICRP reference phantoms. The absorbed dose estimation was performed using the EGSnrc Monte Carlo code and a parallel source algorithm. In this work were used a patient-specific phantom for a man (1.73m/70.3kg) and another for a woman (1.63m/60.3kg) and the male and female ICRP reference phantoms. The comparison of the absorbed dose from each phantom gender was performed using the relative error. The results were expressed in terms of conversion coefficients to brain, lungs, liver and kidneys. The greatest absolute relative error between the organs of the patient-specific phantom and the reference phantom was 22.92% in the liver and 62.84% in the kidneys, respectively for man and woman. There are errors that cannot be disregarded. This paper shows the need for a specific study for each patient or for the population of each country, since there are different body types, which affects the distribution of the organ doses. (author)

  13. Focus Groups to Reveal Parents' Needs for Prenatal Education

    OpenAIRE

    Dumas, Louise

    2002-01-01

    Focus group interviews are a useful qualitative research technique to obtain data from small groups about their opinions, attitudes, and/or feelings on a given subject. This particular technique has been used in Western Quebec in order to reveal the opinions, needs, and feelings of health professionals and future parents concerning prenatal education. As part of the region's priorities for 2002, all future parents in this part of the province were to be offered prenatal, government-paid, comm...

  14. Efficacy of the Positive Parenting Program (Triple-P for a Group of Parents of Children with Attention Deficit Hyperactivity Disorder (ADHD

    Directory of Open Access Journals (Sweden)

    Mehdi Tehranidoost

    2008-07-01

    Full Text Available "nObjective: To evaluate the efficacy of the Positive Parenting Program (Triple-P for parents of children with attention deficit hyperactivity disorder (ADHD. "nMethod:  Sixty families who had at least one child with clinically diagnosed ADHD aged between 6 to12 were recruited from the consecutive referrals to a child and adolescent psychiatric clinic. Families were randomly assigned to the intervention group (who participated in an 8- week- group Triple-P, N=30 and a control group (N=30. Parents completed the battery of self-report questionnaires of triple-P at the beginning and after the 8th session. "nResults: There were no significant differences in pre intervention measures between the two groups. Comparing the pre and post intervention data, the Triple- P group was associated with significantly lower levels of parent reported child behavior problems (P=0.001, lower levels of dysfunctional parenting (P=0.001 and greater parental competence (P=0.001 than the control group. The parents the in triple-P group had significant improvement on measures of depression, anxiety and stress, in comparison with the control group (P=0.001. This study did not follow the long term effect which marks its limitation. "nConclusion: The Triple-P program can be recommended for parents of children with ADHD to reduce the problem behavior of their children and to improve their abilities.

  15. Lost in translation: a focus group study of parents' and adolescents' interpretations of underage drinking and parental supply.

    Science.gov (United States)

    Jones, Sandra C; Andrews, Kelly; Berry, Nina

    2016-07-13

    Reductions in underage drinking will only come about from changes in the social and cultural environment. Despite decades of messages discouraging parental supply, parents perceive social norms supportive of allowing children to consume alcohol in 'safe' environments. Twelve focus groups conducted in a regional community in NSW, Australia; four with parents of teenagers (n = 27; 70 % female) and eight with adolescents (n = 47; 55 % female). Participants were recruited using local media. Groups explored knowledge and attitudes and around alcohol consumption by, and parental supply of alcohol to, underage teenagers; and discussed materials from previous campaigns targeting adolescents and parents. Parents and adolescents perceived teen drinking to be a common behaviour within the community, but applied moral judgements to these behaviours. Younger adolescents expressed more negative views of teen drinkers and parents who supply alcohol than older adolescents. Adolescents and parents perceived those who 'provide alcohol' (other families) as bad parents, and those who 'teach responsible drinking' (themselves) as good people. Both groups expressed a preference for high-fear, victim-blaming messages that targeted 'those people' whose behaviours are problematic. In developing and testing interventions to address underage drinking, it is essential to ensure the target audience perceive themselves to be the target audience. If we do not have a shared understanding of underage 'drinking' and parental 'provision', such messages will continue to be perceived by parents who are trying to do the 'right' thing as targeting a different behaviour and tacitly supporting their decision to provide their children with alcohol.

  16. Children of Mentally Ill Parents Participating in Preventive Support Groups: Parental Diagnoses and Child Risk

    NARCIS (Netherlands)

    Santvoort, F. van; Hosman, C.M.H.; Doesum, K.T.M. van; Janssens, J.M.A.M.

    2014-01-01

    In the Netherlands, preventive support groups are offered to children of mentally ill parents. Given the variety of parental diagnoses it might be questionable if offering a standardized program for all these children is the most effective response. While no overall knowledge exists about the type

  17. The Impact of Gestalt Group Psychotherapy on Parents' Perceptions of Children Identified as Problematic.

    Science.gov (United States)

    Little, Linda F.

    Gestalt therapy respects parents' perceptions of their children and does not attempt to train parents to become therapists for their children. To examine the impact of Gestalt group psychotherapy on parents' perceptions of children identified as problematic, an experimental group of 10 parents participated in 10 2-hour Gestalt sessions. A group of…

  18. The role as moderator and mediator in parent education groups--a leadership and teaching approach model from a parent perspective.

    Science.gov (United States)

    Forslund Frykedal, Karin; Rosander, Michael

    2015-07-01

    To investigate the didactic and social leadership in parent education groups based on a parent perspective, and to conceptualise parent experiences of the leader roles in these groups. Leadership in parent education groups has been associated with a lack of confidence in one's ability to function in that role. Research on how it can be delivered to produce a favourable outcome is scarce. It can be difficult to abandon the role of expert and let participants set their own learning agenda. To facilitate these processes requires leadership skills, knowledge of group dynamics as well as pedagogical skills. Qualitative interview study. Semi-structured interviews with parents (25 participants, 21 interviews). Transcripts were analysed using, first, thematic analysis, then comparative analysis. The study resulted in a four-field model, The Leadership - Teaching Approach model. It consists of the dimensions 'Teaching approaches' ('Knowledge is imparted' and 'Knowledge is jointly constructed'), and 'Leadership approaches' ('Instrumental approach' and 'Investigative approach'). Using an investigative approach is necessary to get a well-functioning group that can help the expectant and new parents in the transition to parenthood. Supervision can help develop an awareness of one's professional role as a nurse and leader of a parent education group. The actions and choices of nurses as leaders of parent groups have an impact on how the participants perceive and take in the content and purpose of the group, and whether they perceive it as meaningful. Getting support in reflecting about one's role as a leader in this context can help create a learning environment in which the participants can become engaged in the activities and be strengthened by the experience. © 2015 John Wiley & Sons Ltd.

  19. Preliminary Study on Hybrid Computational Phantom for Radiation Dosimetry Based on Subdivision Surface

    International Nuclear Information System (INIS)

    Jeong, Jong Hwi; Choi, Sang Hyoun; Cho, Sung Koo; Kim, Chan Hyeong

    2007-01-01

    The anthropomorphic computational phantoms are classified into two groups. One group is the stylized phantoms, or MIRD phantoms, which are based on mathematical representations of the anatomical structures. The shapes and positions of the organs and tissues in these phantoms can be adjusted by changing the coefficients of the equations in use. The other group is the voxel phantoms, which are based on tomographic images of a real person such as CT, MR and serially sectioned color slice images from a cadaver. Obviously, the voxel phantoms represent the anatomical structures of a human body much more realistically than the stylized phantoms. A realistic representation of anatomical structure is very important for an accurate calculation of radiation dose in the human body. Consequently, the ICRP recently has decided to use the voxel phantoms for the forthcoming update of the dose conversion coefficients. However, the voxel phantoms also have some limitations: (1) The topology and dimensions of the organs and tissues in a voxel model are extremely difficult to change, and (2) The thin organs, such as oral mucosa and skin, cannot be realistically modeled unless the voxel resolution is prohibitively high. Recently, a new approach has been implemented by several investigators. The investigators converted their voxel phantoms to hybrid computational phantoms based on NURBS (Non-Uniform Rational B-Splines) surface, which is smooth and deformable. It is claimed that these new phantoms have the flexibility of the stylized phantom along with the realistic representations of the anatomical structures. The topology and dimensions of the anatomical structures can be easily changed as necessary. Thin organs can be modeled without affecting computational speed or memory requirement. The hybrid phantoms can be also used for 4-D Monte Carlo simulations. In this preliminary study, the external shape of a voxel phantom (i.e., skin), HDRK-Man, was converted to a hybrid computational

  20. Individual and group based parenting programmes for improving psychosocial outcomes for teenage parents and their children

    Science.gov (United States)

    Barlow, Jane; Smailagic, Nadja; Bennett, Cathy; Huband, Nick; Jones, Hannah; Coren, Esther

    2014-01-01

    Background Parenting programmes are a potentially important means of supporting teenage parents and improving outcomes for their children, and parenting support is a priority across most Western countries. This review updates the previous version published in 2001. Objectives To examine the effectiveness of parenting programmes in improving psychosocial outcomes for teenage parents and developmental outcomes in their children. Search methods We searched to find new studies for this updated review in January 2008 and May 2010 in CENTRAL, MEDLINE, EMBASE, ASSIA, CINAHL, DARE, ERIC, PsycINFO, Sociological Abstracts and Social Science Citation Index. The National Research Register (NRR) was last searched in May 2005 and UK Clinical Research Network Portfolio Database in May 2010. Selection criteria Randomised controlled trials assessing short-term parenting interventions aimed specifically at teenage parents and a control group (no-treatment, waiting list or treatment-as-usual). Data collection and analysis We assessed the risk of bias in each study. We standardised the treatment effect for each outcome in each study by dividing the mean difference in post-intervention scores between the intervention and control groups by the pooled standard deviation. Main results We included eight studies with 513 participants, providing a total of 47 comparisons of outcome between intervention and control conditions. Nineteen comparisons were statistically significant, all favouring the intervention group. We conducted nine meta-analyses using data from four studies in total (each meta-analysis included data from two studies). Four meta-analyses showed statistically significant findings favouring the intervention group for the following outcomes: parent responsiveness to the child post-intervention (SMD −0.91, 95% CI −1.52 to −0.30, P = 0.04); infant responsiveness to mother at follow-up (SMD −0.65, 95% CI −1.25 to −0.06, P = 0.03); and an overall measure of parent

  1. Phantom position dependence

    International Nuclear Information System (INIS)

    Thorson, M.R.; Endres, G.W.R.

    1981-01-01

    Sensitivity of the Hanford dosimeter response to its position relative to the phantom and the neutron source has always been recognized. A thorough investigation was performed to quantify dosimeter response according to: (a) dosimeter position on phantom, (b) dosimeter distance from phantom, and (c) angular relationship of dosimeter relative to neutron source and phantom. Results were obtained for neutron irradiation at several different energies

  2. Comparing Web, Group and Telehealth Formats of a Military Parenting Program

    Science.gov (United States)

    2016-06-01

    materials are available upon request: • Online questionnaire for baseline data collection (9 pages) • Online parent survey for time point 1 (69 pages...web-based parenting intervention for military families with school-aged children, we expect to strengthen parenting practices in families and...AWARD NUMBER: W81XWH-14-1-0143 TITLE: Comparing Web, Group and Telehealth Formats of a Military Parenting Program PRINCIPAL INVESTIGATOR

  3. Food parenting measurement issues: working group consensus report.

    Science.gov (United States)

    Hughes, Sheryl O; Frankel, Leslie A; Beltran, Alicia; Hodges, Eric; Hoerr, Sharon; Lumeng, Julie; Tovar, Alison; Kremers, Stef

    2013-08-01

    Childhood obesity is a growing problem. As more researchers become involved in the study of parenting influences on childhood obesity, there appears to be a lack of agreement regarding the most important parenting constructs of interest, definitions of those constructs, and measurement of those constructs in a consistent manner across studies. This article aims to summarize findings from a working group that convened specifically to discuss measurement issues related to parental influences on childhood obesity. Six subgroups were formed to address key measurement issues. The conceptualization subgroup proposed to define and distinguish constructs of general parenting styles, feeding styles, and food parenting practices with the goal of understanding interrelating levels of parental influence on child eating behaviors. The observational subgroup identified the need to map constructs for use in coding direct observations and create observational measures that can capture the bidirectional effects of parent-child interactions. The self-regulation subgroup proposed an operational definition of child self-regulation of energy intake and suggested future measures of self-regulation across different stages of development. The translational/community involvement subgroup proposed the involvement of community in the development of surveys so that measures adequately reflect cultural understanding and practices of the community. The qualitative methods subgroup proposed qualitative methods as a way to better understand the breadth of food parenting practices and motivations for the use of such practices. The longitudinal subgroup stressed the importance of food parenting measures sensitive to change for use in longitudinal studies. In the creation of new measures, it is important to consider cultural sensitivity and context-specific food parenting domains. Moderating variables such as child temperament and child food preferences should be considered in models.

  4. Parenting capacity assessment for the court in a multifamily group setting

    Directory of Open Access Journals (Sweden)

    Roberta Di Pasquale

    2016-11-01

    Full Text Available Parenting capacity assessment in court evaluations is a particularly complex task, given that it is necessary to consider the vast array of distinct and interrelated aspects and abilities which represent parenting, as well as the elevated number of contextual levels that influence parenting quality. The perspective we want to introduce regards the potentiality of the multifamily group as the elective observational setting in parenting capacity assessment.

  5. Parenting Stress through the Lens of Different Clinical Groups: a Systematic Review & Meta-Analysis

    Science.gov (United States)

    Mendez, Lucybel; Graziano, Paulo A.; Bagner, Daniel M.

    2017-01-01

    Research has demonstrated an association between parenting stress and child behavior problems, and suggested levels of parenting stress are higher among parents of children at risk for behavior problems, such as those with autism and developmental delay (ASD/DD). The goal of the present study was to conduct a systematic review of parenting stress and child behavior problems among different clinical groups (i.e., ASD/DD, chronic illness, with or at-risk for behavioral and/or mood disorders). We also examined demographic and methodological variables as moderators and differences in overall levels of parenting stress between the clinical groups. This systematic review documents a link between parenting stress and child behavior problems with an emphasis on externalizing behavior. One-hundred thirty-three studies were included for quantitative analysis. Parenting stress was more strongly related to child externalizing (weighted ES r = 0.57, d = 1.39) than internalizing (weighted ES r = 0.37, d = 0.79) problems. Moderation analyses indicated that the association between parenting stress and behavior problems was stronger among studies which had mostly male and clinic-recruited samples. Overall, parenting stress levels were higher for parents of children with ASD/DD compared to parents of children from other clinical groups. Findings document the association between parenting stress and child behavior problems and highlight the importance of assessing parenting stress as part of routine care and throughout behavioral intervention programs, especially for groups of children at high risk for behavior problems, such as children with ASD/DD, in order to identify support for both the parent(s) and child. PMID:28555335

  6. UK parents' attitudes towards meningococcal group B (MenB) vaccination: a qualitative analysis.

    Science.gov (United States)

    Jackson, Cath; Yarwood, Joanne; Saliba, Vanessa; Bedford, Helen

    2017-05-04

    (1) To explore existing knowledge of, and attitudes, to group B meningococcal disease and serogroup B meningococcal (MenB) vaccine among parents of young children. (2) To seek views on their information needs. Cross-sectional qualitative study using individual and group interviews conducted in February and March 2015, prior to the introduction of MenB vaccine (Bexsero) into the UK childhood immunisation schedule. Community centres, mother and toddler groups, parents' homes and workplaces in London and Yorkshire. 60 parents of children under 2 years of age recruited via mother and baby groups and via an advert posted to a midwife-led Facebook group. Although recognising the severity of meningitis and septicaemia, parents' knowledge of group B meningococcal disease and MenB vaccine was poor. While nervous about fever, most said they would take their child for MenB vaccination despite its link to fever. Most parents had liquid paracetamol at home. Many were willing to administer it after MenB vaccination as a preventive measure, although some had concerns. There were mixed views on the acceptability of four vaccinations at the 12-month booster visit; some preferred one visit, while others favoured spreading the vaccines over two visits. Parents were clear on the information they required before attending the immunisation appointment. The successful implementation of the MenB vaccination programme depends on its acceptance by parents. In view of parents' recognition of the severity of meningitis and septicaemia, and successful introduction of other vaccines to prevent bacterial meningitis and septicaemia, the MenB vaccination programme is likely to be successful. However, the need for additional injections, the likelihood of post-immunisation fever and its management are issues about which parents will need information and reassurance from healthcare professionals. Public Health England has developed written information for parents, informed by these findings.

  7. Effective Group Work for Elementary School-Age Children Whose Parents Are Divorcing.

    Science.gov (United States)

    DeLucia-Waack, Janice; Gerrity, Deborah

    2001-01-01

    Parental divorce is the issue of most concern for elementary school children. This article describes interventions for children-of-divorce groups for elementary school children. Suggests guidelines related to goal setting; securing agency and parental consent; leadership planning; recruitment, screening, and selection of members; group member…

  8. Online group course for parents with mental illness: development and pilot study.

    Science.gov (United States)

    van der Zanden, Rianne A P; Speetjens, Paula A M; Arntz, Karlijn S E; Onrust, Simone A

    2010-12-19

    Children of parents with mental illness (COPMI) are at greater risk of developing mental disorders themselves. Since impaired parenting skills appear to be a crucial factor, we developed a facilitated 8-session preventative group course called KopOpOuders (Chin Up, Parents) delivered via the Internet to Dutch parents with psychiatric problems. The goal was to promote children's well-being by strengthening children's protective factors via their parents. To reach parents at an early stage of their parenting difficulties, the course is easily accessible online. The course is delivered in a secure chat room, and participation is anonymous. This paper reports on (1) the design and method of this online the group course and (2) the results of a pilot study that assessed parenting skills, parental sense of competence, child well-being, and course satisfaction. The pilot study had a pre/post design. Parenting skills were assessed using Laxness and Overreactivity subscales of the Parenting Scale (PS). Sense of parenting competence was measured with the Ouderlijke Opvattingen over Opvoeding (OOO) questionnaire, a Dutch scale assessing parental perceptions of parenting using the Feelings of Incompetence and Feelings of Competence subscales. Child well-being was assessed with the total problem score, Emotional Problems, and Hyperactivity subscales of the Strengths and Difficulties Questionnaire (SDQ). Paired samples t tests were performed, and Cohen's d was used to determine effect sizes. Intention-to-treat analyses and analyses of completers only were both performed. Course satisfaction was evaluated using custom-designed questionnaires. The sample comprised 48 parents with mental illness. The response rate was 100% (48/48) at pretest and 58% (28/48) at posttest. Significant improvements were found on PS Laxness and Overreactivity subscales (P children were not in the clinical range at both pretest and posttest. The mean course satisfaction score was 7.8 on a 10-point scale

  9. Parental interaction patterns in children with attention deficit hyperactive disorder and control group

    Directory of Open Access Journals (Sweden)

    Mojgan Karahmadi

    2007-07-01

    Full Text Available

    BACKGROUND: Parental communication patterns influence children's personality. This study investigated effects of parental interaction patterns on children with attention deficit hyperactive disorder (ADHD.
    METHODS: There were 50 male children, 7-12 years old, selected in two groups. The first group included students with ADHD referred to psychiatry clinics in Isfahan-based on diagnostic scale of DSM-IV (25 subjects. The second group involved healthy boys selected by random cluster multistage sampling from primary schools in five districts of Isfahan (25 subjects from September 2005 to March 2005. Schaffer and Edgerton parental interaction questionnaire was filled for them.
    RESULTS: Mean scores of parental interaction patterns in healthy children were all higher than those in ADHD children except for “aggression control” and “lack of aggressive attachment”.
    CONCLUSIONS: The severity of ADHD signs has negative relationship with parental "admission" and parental "control" patterns. It also has positive relationship with “lack of aggressive/attachment” and “aggressive/control” patterns.
    KEY WORDS: Parental interaction patterns, ADHD.

  10. Children of mentally ill parents – a pilot study of a group intervention program

    Directory of Open Access Journals (Sweden)

    Hanna eChristiansen

    2015-10-01

    Full Text Available The transgenerational transmission of mental disorders is one of the most prominent risk factors for the development of psychological disorders. To date there are only a few evidence based intervention programs for this group overall and hardly any in Germany. We translated the evidence based Family Talk Intervention by Beardslee (2009 and adapted it for groups. In a quasi-experimental design three groups are compared: an intervention group (Family Talk Intervention group: n = 28, a Wait Control group (n = 9, and a control group of healthy children (n = 40. Children of mentally ill parents showed higher rates of internalizing/externalizing disorders before and after the intervention compared to children of parents with no disorders. Post intervention children’s knowledge on mental disorders was significantly enhanced in the Family Talk Intervention group and externalizing symptoms were reduced for this group as well. This pilot study of a group intervention for children of mentally ill parents highlights the importance of psycho-education on parental mental disorders for children. Long-term effects of children’s enhanced knowledge about parental psychopathology need to be explored in future studies.

  11. The value of evaluating parenting groups: a new researcher's perspective on methods and results.

    Science.gov (United States)

    Cabral, Judy

    2013-06-01

    The aim of this research project was to evaluate the impact of the Solihull Approach Understanding Your Child's Behaviour (UYCB) parenting groups on the participants' parenting practice and their reported behaviour of their children. Validated tools that met both the Solihull Child and Adolescent Mental Health Service (CAMHS) and academic requirements were used to establish what changes, if any, in parenting practice and children's behaviour (as perceived by the parent) occur following attendance of a UYCB parenting group. Independent evidence of the efficacy of the Solihull Approach UYCB programme was collated. Results indicated significant increases in self-esteem and parenting sense of competence; improvement in the parental locus of control; a decrease in hyperactivity and conduct problems and an increase in pro-social behaviour, as measured by the 'Strength and Difficulties' questionnaire. The qualitative and quantitative findings corroborated each other, demonstrating the impact and effectiveness of the programme and supporting anecdotal feedback on the success of UYCB parenting groups.

  12. Extended parental care in communal social groups

    Directory of Open Access Journals (Sweden)

    Stephen H. Forbes

    2002-11-01

    Full Text Available Recent developments in social insect research have challenged the need for close kinship as a prerequisite for the evolution of stable group living. In a model communal bee species, Lasioglossum (Chilalictus hemichalceum, previous allozyme work indicated that groups of cooperating adult females are not relatives. Yet at any given time, not all group members perform the risky task of foraging. We previously hypothesized that tolerance for non-foragers was a component of extended parental care, previously known only for kin based social systems. DNA microsatellites were used to study colony genetic structure in order to test this hypothesis. Microsatellite polymorphism was substantial (He = 0.775. Overall intracolony relatedness, mainly of immatures, was low but significant in nine, late season nests (r = 0.136 plus or minus0.023, indicating that broods contain five to six unrelated sib ships. Detailed analyses of kinship between pairs of individuals revealed that most pairs were unrelated and most related pairs were siblings. Mothers are absent for 89-91% of the developing immature females, and 97% of developing males. Alternatively, 46% of adult females had neither sibs nor offspring in their nests. These findings indicate that the extended parental care model applies broadly to both kin based and nonkin based social systems in the Hymenoptera.

  13. Phantom pain and phantom sensations in upper limb amputees : an epidemiological study

    NARCIS (Netherlands)

    Kooijman, CM; Dijkstra, PU; Geertzen, JHB; Elzinga, A; van der Schans, CP

    Phantom pain in subjects with an amputated limb is a well-known problem. However, estimates of the prevalence of phantom pain differ considerably in the literature. Various factors associated with phantom pain have been described including pain before the amputation, gender, dominance, and time

  14. Individual virtual phantom reconstruction for organ dosimetry based on standard available phantoms

    International Nuclear Information System (INIS)

    Babapour Mofrad, F.; Aghaeizadeh Zoroofi, R.; Abbaspour Tehran Fard, A.; Akhlaghpoor, Sh.; Chen, Y. W.; Sato, Y.

    2010-01-01

    In nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. Monte Carlo Simulation and phantoms have been used in many works before. The shape, size and volume In organs are varied, and this variation will produce error in dose calculation if no correction is applied. Materials and Methods: A computational framework for constructing individual phantom for dosimetry was performed on five liver CT scan data sets of Japanese normal individuals. The Zubal phantom was used as an original phantom to be adjusted by each individual data set. This registration was done by Spherical Harmonics and Thin-Plate Spline methods. Hausdorff distance was calculated for each case. Results: Result of Hausdorff distance for five lndividual phantoms showed that before registration ranged from 140.9 to 192.1, and after registration it changed to 52.5 to 76.7. This was caused by Index similarity ranged from %56.4 to %70.3. Conclusion: A new and automatic three-dimensional (3D) phantom construction approach was-suggested for individual internal dosimetry simulation via Spherical Harmonics and Thin-Plate Spline methods. The results showed that the Individual comparable phantom can be calculated with acceptable accuracy using geometric registration. This method could be used for race-specific statistical phantom modeling with major application in nuclear medicine for absorbed dose calculation.

  15. Why parents refuse childhood vaccination: a qualitative study using online focus groups

    Science.gov (United States)

    2013-01-01

    Background In high income countries, vaccine-preventable diseases have been greatly reduced through routine vaccination programs. Despite this success, many parents question, and a small proportion even refuse vaccination for their children. As no qualitative studies have explored the factors behind these decisions among Dutch parents, we performed a study using online focus groups. Methods In total, eight online focus groups (n = 60) which included Dutch parents with at least one child, aged 0–4 years, for whom they refused all or part of the vaccinations within the National Immunization Program (NIP). A thematic analysis was performed to explore factors that influenced the parents’ decisions to refuse vaccination. Results Refusal of vaccination was found to reflect multiple factors including family lifestyle; perceptions about the child’s body and immune system; perceived risks of disease, vaccine efficacy, and side effects; perceived advantages of experiencing the disease; prior negative experience with vaccination; and social environment. The use of online focus groups proved to be an effective qualitative research method providing meaningful data. Conclusion Information provided by the NIP turned out to be insufficient for this group of parents. More trust in the NIP and deliberate decisions might result from increased parental understanding of lifestyle and disease susceptibility, the impact of vaccinations on the immune system, and the relative risks of diseases and their vaccines. The public health institute should also inform parents that the NIP is recommended but non-mandatory. PMID:24341406

  16. Reducing Preschoolers' Disruptive Behavior in Public with a Brief Parent Discussion Group

    Science.gov (United States)

    Joachim, Sabine; Sanders, Matthew R.; Turner, Karen M. T.

    2010-01-01

    This study examined the efficacy of a brief 2-h discussion group for parents of preschool children that show disruptive behavior on shopping trips. Forty-six parents with children aged 2-6 years were randomly assigned to either the intervention condition or a waitlist control group. Significant intervention effects were found for measures of…

  17. Group-based antenatal birth and parent preparation for improving birth outcomes and parenting resources: Study protocol for a randomised trial

    DEFF Research Database (Denmark)

    Koushede, Vibeke; Brixval, Carina Sjöberg; Axelsen, Solveig Forberg

    2013-01-01

    To examine the efficacy and cost-effectiveness of group based antenatal education for improving childbirth and parenting resources compared to auditorium based education.......To examine the efficacy and cost-effectiveness of group based antenatal education for improving childbirth and parenting resources compared to auditorium based education....

  18. Experimental and computational development of a natural breast phantom for dosimetry studies

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2013-01-01

    This paper describes the experimental and computational development of a natural breast phantom, anthropomorphic and anthropometric for studies in dosimetry of brachytherapy and teletherapy of breast. The natural breast phantom developed corresponding to fibroadipose breasts of women aged 30 to 50 years, presenting radiographically medium density. The experimental breast phantom was constituted of three tissue-equivalents (TE's): glandular TE, adipose TE and skin TE. These TE's were developed according to chemical composition of human breast and present radiological response to exposure. Completed the construction of experimental breast phantom this was mounted on a thorax phantom previously developed by the research group NRI/UFMG. Then the computational breast phantom was constructed by performing a computed tomography (CT) by axial slices of the chest phantom. Through the images generated by CT a computational model of voxels of the thorax phantom was developed by SISCODES computational program, being the computational breast phantom represented by the same TE's of the experimental breast phantom. The images generated by CT allowed evaluating the radiological equivalence of the tissues. The breast phantom is being used in studies of experimental dosimetry both in brachytherapy as in teletherapy of breast. Dosimetry studies by MCNP-5 code using the computational model of the phantom breast are in progress. (author)

  19. Learning from the Experts: A Thematic Analysis of Parent's Experiences of Attending a Therapeutic Group for Parents of Children with Learning Disabilities and Challenging Behaviour

    Science.gov (United States)

    Thompson-Janes, Emily; Brice, Samuel; McElroy, Rebecca; Abbott, Jennie; Ball, June

    2016-01-01

    The Confident Parenting group is a therapeutic group for parents of children with learning disabilities and challenging behaviour, which is informed by the principles of behavioural theory and acceptance and commitment therapy. Parent's experiences of the group were elicited through participation in a large focus group which followed a…

  20. Direct and Indirect Psychosocial Outcomes for Children with Autism Spectrum Disorder and their Parents Following a Parent-involved Social Skills Group Intervention.

    Science.gov (United States)

    Weiss, Jonathan A; Viecili, Michelle A; Sloman, Leon; Lunsky, Yona

    2013-11-01

    This study examined the direct and indirect outcomes of a social skills group intervention for children with high functioning autism spectrum disorders and their parents. Thirty-five children and their parents participated in the program evaluation. Children and parents completed measures of child social skills and problem behaviors. Children reported on their self-concept, and parents reported on their psychological acceptance and empowerment. Results indicate significant increases in overall child social skills according to parent and child report, in child general self-worth, and in parent service empowerment and psychological acceptance. While past program evaluations of social skills groups highlight changes in social competence, taking a broader perspective on the types of positive outcomes suggests potential benefits for both child and parent.

  1. Tissue quantification for development of pediatric phantom

    International Nuclear Information System (INIS)

    Alves, A.F.F.; Miranda, J.R.A.; Pina, D.R.

    2013-01-01

    The optimization of the risk- benefit ratio is a major concern in the pediatric radiology, due to the greater vulnerability of children to the late somatic effects and genetic effects of exposure to radiation compared to adults. In Brazil, it is estimated that the causes of death from head trauma are 18 % for the age group between 1-5 years and the radiograph is the primary diagnostic test for the detection of skull fracture . Knowing that the image quality is essential to ensure the identification of structures anatomical and minimizing errors diagnostic interpretation, this paper proposed the development and construction of homogeneous phantoms skull, for the age group 1-5 years. The construction of the phantoms homogeneous was performed using the classification and quantification of tissue present in the skull of pediatric patients. In this procedure computational algorithms were used, using Matlab, to quantify distinct biological tissues present in the anatomical regions studied , using pictures retrospective CT scans. Preliminary data obtained from measurements show that between the ages of 1-5 years, assuming an average anteroposterior diameter of the pediatric skull region of the 145.73 ± 2.97 mm, can be represented by 92.34 mm ± 5.22 of lucite and 1.75 ± 0:21 mm of aluminum plates of a provision of PEP (Pacient equivalent phantom). After its construction, the phantoms will be used for image and dose optimization in pediatric protocols process to examinations of computerized radiography

  2. Examining Parents’ Preferences for Group and Individual Parent Training For Children with ADHD Symptoms

    Science.gov (United States)

    Wymbs, Frances A.; Cunningham, Charles E.; Chen, Yvonne; Rimas, Heather M.; Deal, Ken; Waschbusch, Daniel A.; Pelham, William E.

    2015-01-01

    Parent training (PT) programs have been found to reduce some behavioral impairment associated with children’s attention deficit hyperactivity disorder (ADHD) as well as improve parenting competence, but poor uptake and participation by parents are formidable barriers that affect service effectiveness. We used a discrete choice experiment (DCE) to examine how parent preferences for treatment format (i.e. group versus individual) might influence their participation in PT. Participants were 445 parents seeking mental health services for children with elevated symptoms of ADHD in Ontario, Canada. Parents completed a discrete-choice experiment (DCE) composed of 30 choice tasks used to gauge PT format preference. Results showed that 58.7% of parents preferred individual PT; these parents were most interested in interventions that would make them feel more informed about their child’s problems and in understanding—as opposed to solving—their child’s problems. A minority of parents (19.4 %) preferred group PT; these parents were most interested in active, skill-building services that would help them solve their child’s problems. About one-fifth of parents (21.9 %) preferred the Minimal Information alternative (i.e. receiving neither individual or group PT); these parents reported the highest levels of depression and the most severe mental health problems in their child. Results highlight the importance of considering parent preferences for format, and suggest that alternative formats to standard PT should be considered for multiply stressed families. PMID:25700219

  3. Reducing Schoolchildren With Reactive Aggression Through Child, Parent, and Conjoint Parent-Child Group Interventions: A Longitudinal Outcome Effectiveness Study.

    Science.gov (United States)

    Fung, Annis Lai Chu

    2017-10-10

    This study was the first to evaluate the effectiveness of three different group interventions to reduce children's reactive aggression based on the social information processing (SIP) model. In the first stage of screening, 3,734 children of Grades 4-6 completed the Reactive-Proactive Aggression Questionnaire (RPQ) to assess their reactive and proactive aggression. Respondents with a total score of z ≥ 1 on the RPQ were shortlisted for the second stage of screening by qualitative interview. Interviews with 475 children were conducted to select those who showed reactive aggression featuring a hostile attributional bias. Finally, 126 children (97 males and 29 females) aged 8 to 14 (M = 9.71, SD = 1.23) were selected and randomly assigned to one of the three groups: a child group, a parent group, and a parent-child group. A significant Time × Intervention effect was found for general and reactive aggression. The parent-child group and child group showed a significant drop in general aggression and reactive aggression from posttest to 6-month follow-up, after controlling for baseline scores, sex, and age. However, the parent group showed no treatment effect: reactive aggression scores were significantly higher than those in the child group at 6-month follow-up. This study has provided strong evidence that children with reactive aggression need direct and specific treatment to reconstruct the steps of the SIP involving the selection and interpretation of cues. The intervention could help to prevent severe violent crimes at the later stage of a reactive aggressor. © 2017 Family Process Institute.

  4. Effect of a group intervention for children and their parents who have cancer.

    Science.gov (United States)

    Kobayashi, Mariko; Heiney, Sue P; Osawa, Kaori; Ozawa, Miwa; Matsushima, Eisuke

    2017-10-01

    Although support programs for children whose parents have cancer have been described and evaluated, formal research has not been conducted to document outcomes. We adapted a group intervention called CLIMB®, originally developed in the United States, and implemented it in Tokyo, Japan, for school-aged children and their parents with cancer. The purpose of this exploratory pilot study was to examine the feasibility, acceptability, and impact of the Japanese version of the CLIMB® Program on children's stress and parents' quality of life and psychosocial distress. We enrolled children and parents in six waves of replicate sets for the six-week group intervention. A total of 24 parents (23 mothers and 1 father) diagnosed with cancer and 38 school-aged children (27 girls and 11 boys) participated in our study. Intervention fidelity, including parent and child satisfaction with the program, was examined. The impact of the program was analyzed using a quasiexperimental within-subject design comparing pre- and posttest assessments of children and parents in separate analyses. Both children and parents experienced high levels of satisfaction with the program. Children's posttraumatic stress symptoms related to a parent's illness decreased after the intervention as measured by the Posttraumatic Stress Disorder-Reaction Index. No difference was found in children's psychosocial stress. The Functional Assessment of Chronic Illness Therapy scores indicated that parents' quality of life improved after the intervention in all domains except for physical well-being. However, no differences were found in parents' psychological distress and posttraumatic stress symptoms. Our results suggest that the group intervention using the CLIMB® Program relieved children's posttraumatic stress symptoms and improved parents' quality of life. The intervention proved the feasibility of delivering the program using manuals and training. Further research is needed to provide more substantiation

  5. Parents' experiences and perceptions of group-based antenatal care in four clinics in Sweden.

    Science.gov (United States)

    Andersson, Ewa; Christensson, Kyllike; Hildingsson, Ingegerd

    2012-08-01

    group-based antenatal care consists of six to nine two-hour sessions in which information is shared and discussed during the first hour and individual examinations are conducted during the second hour. Groups generally consist of six to eight pregnant women. Parent education is built into the programme, which originated in the United States and was introduced in Sweden at the beginning of the year of 2000. to investigate parents' experiences of group antenatal care in four different clinics in Sweden. a qualitative study was conducted using content analysis five group interviews and eleven individual interviews with parents who experienced group-based antenatal care. An interview guide was used. the study was set in four antenatal clinics that had offered group-based antenatal care for at least one year. The clinics were located in three different areas of Sweden. the participants were women and their partners who had experienced group-based antenatal care during pregnancy. Other criteria for participation were mastery of the Swedish language and having followed the care programme. three themes emerged, 'The care-combining individual physical needs with preparation for parenthood, refers to the context, organisation, and content of care'. Group antenatal care with inbuilt parent education was appreciated, but respondents reported that they felt unprepared for the first few weeks after birth. Their medical needs (for physical assessment and screening) were, however, fulfilled. The theme, 'The group-a composed recipient of care', showed the participants role and experience. The role could be passive or active in groups or described as sharers. Groups helped parents normalise their symptoms. The theme, 'The midwife-a controlling professional', showed midwives are ignorant of gender issues but, for their medical knowledge, viewed as respectable professionals. in the four clinics studied, group-based antenatal care appeared to meet parents' needs for physical assessment

  6. Groups for Parents with Intellectual Disabilities: A Qualitative Analysis of Experiences

    Science.gov (United States)

    Gustavsson, Marie; Starke, Mikaela

    2017-01-01

    Background: Parents with intellectual disabilities (IDs) are often socially isolated and need support. Materials and Methods: This qualitative study is based on participant observations of a group for parents with with intellectual disabilities. Data were categorized and interpreted in the framework of social capital and symbolic interactionism.…

  7. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation...... was conducted by a trained interviewer. Results: Of the 173 patients in the study, 39 experienced phantom pain. The median age of patients who had experienced phantom pain was 45 years (range: 19–88). Follow-up time from eye amputation to participation in the investigation was 4 years (range: 2–46). Phantom...... scale, ranging from 0 to 100, was 36 (range: 1–89). One-third of the patients experienced phantom pain every day. Chilliness, windy weather and psychological stress/fatigue were the most commonly reported triggers for pain. Conclusions: Phantom pain after eye amputation is relatively common. The pain...

  8. Development of breast phantom for quality assessment of mammographic images

    International Nuclear Information System (INIS)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata; Universidade Federal de Minas Gerais; Universidad Complutense de Madrid

    2017-01-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  9. Development of breast phantom for quality assessment of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata, E-mail: jenifferarvelos00@gmail.com [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Biomedica; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Universidad Complutense de Madrid (UCM), Madrid (Spain). Faculdad de Medicina. Departmento de Radiologia

    2017-11-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  10. Hybrid pregnant reference phantom series based on adult female ICRP reference phantom

    Science.gov (United States)

    Rafat-Motavalli, Laleh; Miri-Hakimabad, Hashem; Hoseinian-Azghadi, Elie

    2018-03-01

    This paper presents boundary representation (BREP) models of pregnant female and her fetus at the end of each trimester. The International Commission on Radiological Protection (ICRP) female reference voxel phantom was used as a base template in development process of the pregnant hybrid phantom series. The differences in shape and location of the displaced maternal organs caused by enlarging uterus were also taken into account. The CT and MR images of fetus specimens and pregnant patients of various ages were used to replace the maternal abdominal pelvic organs of template phantom and insert the fetus inside the gravid uterus. Each fetal model contains 21 different organs and tissues. The skeletal model of the fetus also includes age-dependent cartilaginous and ossified skeletal components. The replaced maternal organ models were converted to NURBS surfaces and then modified to conform to reference values of ICRP Publication 89. The particular feature of current series compared to the previously developed pregnant phantoms is being constructed upon the basis of ICRP reference phantom. The maternal replaced organ models are NURBS surfaces. With this great potential, they might have the feasibility of being converted to high quality polygon mesh phantoms.

  11. From Intent to Enrollment, Attendance, and Participation in Preventive Parenting Groups

    Science.gov (United States)

    Dumas, Jean E.; Nissley-Tsiopinis, Jenelle; Moreland, Angela D.

    2007-01-01

    Applying the Theory of Planned Behavior (TPB) to the process of engagement in preventive parenting groups, we tested the ability of family and child measures to predict intent to enroll, enrollment, attendance, and quality of participation in PACE (Parenting Our Children to Excellence). PACE is a prevention trial testing the efficacy of a…

  12. THE ROLE OF SUPPORT GROUPS IN THE COOPERATION BETWEEN PARENTS OF PEOPLE WITH INTELLECTUAL DISABILITIES AND PROFESSIONAL STAFF

    Directory of Open Access Journals (Sweden)

    Metka NOVAK

    2014-09-01

    Full Text Available Introduction: One of the ways of building and developing a better cooperative relationship between parents of people with severe and profound intellectual disabilities and professional staff is the inclusion of parents in support groups for parents and staff in support groups for staff. Goal: To examine the correlation of the level of cooperative relationship between the parents of people with severe and profound intellectual disabilities and professional staff with the inclusion of parents in support groups for parents and staff in support groups for staff. Methodology: Respondents: parents (296 of people with severe and profound learning disabilities and staff (298 in five centres across Slovenia; Methods: descriptive statistics, test of homogeneity, the rankit method, one-way analysis of variance; Procedures: survey questionnaires for parents and staff. The data was processed using SPSS software for personal computers. Results: The difference between the variances of the groups (parent found is statistically significant (F = 6.16; p = 0.01. Staff included in support groups have a significantly lower level of cooperative relationship with parents (f=10; M = - 0.12 than staff not included in these groups (f = 191; M = 0.04. Conclusion:In contrast to theoretical findings the results indicated less successful cooperation for professional staff included in support groups. The results furthermore did not confirm any differences in the cooperative relationship of parents included in support groups and those who are not. We suggest an in-depth analysis of the workings of support groups.

  13. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    International Nuclear Information System (INIS)

    Kiarashi, Nooshin; Nolte, Adam C.; Sturgeon, Gregory M.; Ghate, Sujata V.; Segars, William P.; Nolte, Loren W.; Samei, Ehsan

    2015-01-01

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  14. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    Energy Technology Data Exchange (ETDEWEB)

    Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Nolte, Adam C. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Sturgeon, Gregory M.; Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Segars, William P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Nolte, Loren W. [Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Department of Physics, Duke University, Durham, North Carolina 27708 (United States); and others

    2015-07-15

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  15. NMR-CT image and symbol phantoms

    International Nuclear Information System (INIS)

    Hongo, Syozo; Yamaguchi, Hiroshi; Takeshita, Hiroshi

    1990-01-01

    We have developed Japanese phantoms in two procedures. One is described as a mathematical expression. Another is 'symbol phantoms' in 3 dimensional picture-elements, each of which symbolize an organ name. The concept and the algorithm of the symbol phantom enables us to make a phantom for a individual in terms of all his transversal section images. We got 85 transversal section images of head and trunk parts, and those of 40 legs parts by using NMR-CT. We have made the individual phantom for computation of organ doses. The transversal section images were not so clear to identify all organs needed to dose estimation that we had to do hand-editing the shapes of organs with viewing a typical section images: we could not yet make symbol phantom in a automatic editing. Symbols were coded to be visual cords as ASCII characters. After we got the symbol phantom of the first stage, we can edit it easily using a word-processor. Symbol phantom could describe more freely the shape of organs than mathematical phantom. Symbol phantom has several advantages to be an individual phantom, but the only difficult point is how to determine its end-point as a reference man when we apply the method to build the reference man. (author)

  16. Construction of Chinese reference female phantom

    International Nuclear Information System (INIS)

    Sheng Yinxiangzi; Liu Lixing; Xia Xiaobin

    2013-01-01

    In this study, a Voxel-based Chinese Reference female Phantom (VCRP-woman) is developed from an individual female phantom which was based on high resolution cross-sectional color photographs. An in-house C ++ program was developed to adjust the phantom. Finally, a reference female phantom with have the same height, weighte and similar organs masses with the Chinese reference adult female data. The adjusted phantom is then imported to MCNPX to calculate the organs absorbed dose and effective dose conversion coefficients. Results are compared between VCRP-woman and the ICRP adult reference female phantom. (authors)

  17. Phantom Sensations, Supernumerary Phantom Limbs and Apotemnophilia: Three Body Representation Disorders.

    Science.gov (United States)

    Tatu, Laurent; Bogousslavsky, Julien

    2018-01-01

    Body representation disorders continue to be mysterious and involve the anatomical substrate that underlies the mental representation of the body. These disorders sit on the boundaries of neurological and psychiatric diseases. We present the main characteristics of 3 examples of body representation disorders: phantom sensations, supernumerary phantom limb, and apotemnophilia. The dysfunction of anatomical circuits that regulate body representation can sometimes have paradoxical features. In the case of phantom sensations, the patient feels the painful subjective sensation of the existence of the lost part of the body after amputation, surgery or trauma. In case of apotemnophilia, now named body integrity identity disorder, the subject wishes for the disappearance of the existing and normal limb, which can occasionally lead to self-amputation. More rarely, a brain-damaged patient with 4 existing limbs can report the existence of a supernumerary phantom limb. © 2018 S. Karger AG, Basel.

  18. 21. Phantom pain.

    NARCIS (Netherlands)

    Wolff, A.P.; Vanduynhoven, E.; Kleef, M. van; Huygen, F.; Pope, J.E.; Mekhail, N.

    2011-01-01

    Phantom pain is pain caused by elimination or interruption of sensory nerve impulses by destroying or injuring the sensory nerve fibers after amputation or deafferentation. The reported incidence of phantom limb pain after trauma, injury or peripheral vascular diseases is 60% to 80%. Over half the

  19. Radiation protection to the eye and thyroid during diagnostic cerebral angiography: a phantom study.

    LENUS (Irish Health Repository)

    Shortt, C P

    2008-08-01

    We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  20. Radiation protection to the eye and thyroid during diagnostic cerebral angiography : a phantom study

    International Nuclear Information System (INIS)

    Shortt, C. P.; Malone, L.; Thornton, J.; Brennan, P.; Lee, M. J.

    2008-01-01

    Full text: We measured radiation doses to the eye and thyroid during diagnostic cerebral angiography to assess the effectiveness of bismuth and lead shields at dose reduction. Phantom head angiographic studies were performed with bismuth (study 1) and lead shields (study 2). In study 1 (12 phantoms), thermoluminescent dosimeters (TLD) were placed over the eyes and thyroid in three groups: (i) no shields (four phantoms); (ii) anterior bismuth shields (four phantoms) and (iii) anterior and posterior bismuth shields (four phantoms). In a second study (eight phantoms), lead shields were placed over the thyroid only and TLD dose measurements obtained in two groups: (i) no shielding (four phantoms) and (ii) thyroid lead shielding (four phantoms). A standard 4-vessel cerebral angiogram was performed on each phantom. Study 1 (bismuth shields) showed higher doses to the eyes compared with thyroid (mean 13.03 vs 5.98 mSv, P < 0.001) and a higher eye dose on the X-ray tube side. Overall, the use of bismuth shielding did not significantly reduce dose to either eyes or thyroid in the measured TLD positions. In study 2, a significant thyroid dose reduction was found with the use of lead shields (47%, mean 2.46 vs 4.62 mSv, P < 0.001). Considerable doses to the eyes and thyroid highlight the need for increased awareness of patient protection. Eye shielding is impractical and interferes with diagnostic capability. Thyroid lead shielding yields significant protection to the thyroid, is not in the field of view and should be used routinely.

  1. Construction of Korean female voxel phantom and its application to dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Ik

    2001-08-15

    A Korean female voxel phantom was constructed to overcome the limitations of anatomical description of the existing MRD-type mathematical anthropomorphic phantom and the example dose calculations were carried out for the radiation protection by using it. This whole body voxel phantom was based on the MRIs of the Korean adult female who falls into the reference Korean female group. The cross sectional human pictures from VHP of NLM was adopted for the modification and compensation of the missing MRIs of Korean adult female that include legs below upper thighs. From the gastrointestinal and respiratory organ which make obscure organ edges because of their continuing motion, the general anatomical knowledge were applied for the segmentation process. The Korean female whole body voxel phantom named in HYWOMAN is composed of 1,392,400 voxels that have width x length x height of 4mm x 4mm x 8mm for each with the total of 20 organs identified. With MDNP4B code the tissue equivalent doses were calculated for the four different energies of 0.4, 0.8, 2 and 8 MeV broad parallel gamma beam in AP, PA, LLAT and RLAT directions. The tissue equivalent doses were compared with those of ORNL adult female phantom under the same irradiation conditions. Despite of the small organ differences there could be found the considerable differences in tissue equivalent doses for some organs including thyroid, esophagus, kidneys and spleen. The cause of these discrepancies were proved to be the position of the organs in the phantom and the consequent shielding effects. With the methodology of this study, Korean reference male and female age-grouped voxel phantoms can be constructed and consequently the dosimetry system for typical Korean people is to be established.

  2. Construction of Korean female voxel phantom and its application to dosimetry

    International Nuclear Information System (INIS)

    Lee, Choon Ik

    2001-08-01

    A Korean female voxel phantom was constructed to overcome the limitations of anatomical description of the existing MRD-type mathematical anthropomorphic phantom and the example dose calculations were carried out for the radiation protection by using it. This whole body voxel phantom was based on the MRIs of the Korean adult female who falls into the reference Korean female group. The cross sectional human pictures from VHP of NLM was adopted for the modification and compensation of the missing MRIs of Korean adult female that include legs below upper thighs. From the gastrointestinal and respiratory organ which make obscure organ edges because of their continuing motion, the general anatomical knowledge were applied for the segmentation process. The Korean female whole body voxel phantom named in HYWOMAN is composed of 1,392,400 voxels that have width x length x height of 4mm x 4mm x 8mm for each with the total of 20 organs identified. With MDNP4B code the tissue equivalent doses were calculated for the four different energies of 0.4, 0.8, 2 and 8 MeV broad parallel gamma beam in AP, PA, LLAT and RLAT directions. The tissue equivalent doses were compared with those of ORNL adult female phantom under the same irradiation conditions. Despite of the small organ differences there could be found the considerable differences in tissue equivalent doses for some organs including thyroid, esophagus, kidneys and spleen. The cause of these discrepancies were proved to be the position of the organs in the phantom and the consequent shielding effects. With the methodology of this study, Korean reference male and female age-grouped voxel phantoms can be constructed and consequently the dosimetry system for typical Korean people is to be established

  3. Development of skeletal system for mesh-type ICRP reference adult phantoms

    Science.gov (United States)

    Yeom, Yeon Soo; Wang, Zhao Jun; Tat Nguyen, Thang; Kim, Han Sung; Choi, Chansoo; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Chung, Beom Sun; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik

    2016-10-01

    The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (⩽4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to ~1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.

  4. Exploring Parental and Staff Perceptions of the Family-Integrated Care Model: A Qualitative Focus Group Study.

    Science.gov (United States)

    Broom, Margaret; Parsons, Georgia; Carlisle, Hazel; Kecskes, Zsuzsoka; Thibeau, Shelley

    2017-12-01

    Family-integrated care (FICare) is an innovative model of care developed at Mount Sinai Hospital, Canada, to better integrate parents into the team caring for their infant in the neonatal intensive care unit (NICU). The effects of FICare on neonatal outcomes and parental anxiety were assessed in an international multicenter randomized trial. As an Australian regional level 3 NICU that was randomized to the intervention group, we aimed to explore parent and staff perceptions of the FICare program in our dual occupancy NICU. This qualitative study took place in a level 3 NICU with 5 parent participants and 8 staff participants, using a post implementation review design. Parents and staff perceptions of FICare were explored through focus group methodology. Thematic content analysis was done on focus group transcripts. Parents and staff perceived the FICare program to have had a positive impact on parental confidence and role attainment and thought that FICare improved parent-to-parent and parent-to-staff communication. Staff reported that nurses working with families in the program performed less hands-on care and spent more time educating and supporting parents. FICare may change current NICU practice through integrating and accepting parents as active members of the infant's care team. In addition, nurse's roles may transition from bedside carer to care coordinator, educating and supporting parents during their journey through the NICU. Further research is needed to assess the long-term impact of FICare on neonates, parents, and staff.

  5. Identification of family variables in parents' groups of children with epilepsy

    Directory of Open Access Journals (Sweden)

    Fernandes Paula Teixeira

    2001-01-01

    Full Text Available OBJECTIVE: To verify the effectiveness of the support group in the identification of family variables linked to epilepsy. METHOD: Pre-test were applied to parents of 21 children with benign epilepsy of childhood recently diagnosed, from 5 to 15 years, who participated in the groups at HC/Unicamp. There was a presentation of an educational video, discussion and application of the post-test 1. After six months, the post-test 2 was applied. RESULTS: The beliefs were: fear of swallowing the tongue during the seizures (76.19% and of a future mental disease (66.67%. Facing the epilepsy, fear and sadness appeared. 76.19% of the parents presented overprotection and 90.48%, expected a new seizure. In the post-test 1, the parents affirmed that the information offered had modified the beliefs. In the post-test 2, 80.95% didn't report great doubts about epilepsy and 90.48% considered their relationship with their children better. CONCLUSIONS: The demystification of beliefs supplied from the groups influenced the family positively, prevented behavior alterations and guaranteed effective care in the attendance to the child with epilepsy.

  6. Disappointment and adherence among parents of newborns allocated to the control group

    DEFF Research Database (Denmark)

    Meinich Petersen, Sandra; Zoffmann, Vibeke; Kjærgaard, Jesper

    2014-01-01

    among parents of newborns who were randomized to the control group, but also a broad expression of understanding and accepting the idea of randomization. The trial staff might use the model of reactions in understanding the parents' disappointment and in this way support their motives for participation......BACKGROUND: When a child participates in a clinical trial, informed consent has to be given by the parents. Parental motives for participation are complex, but the hope of getting a new and better treatment for the child is important. We wondered how parents react when their child is allocated...... to achieve saturation. Thematic analysis was used to identify themes across the data sets. RESULTS: The parents reported good understanding of the randomization process. Their most common reaction to allocation was disappointment, though relief was also seen. A model of reactions to being allocated...

  7. Homogeneous Canine Chest Phantom Construction: A Tool for Image Quality Optimization.

    Directory of Open Access Journals (Sweden)

    Ana Luiza Menegatti Pavan

    Full Text Available Digital radiographic imaging is increasing in veterinary practice. The use of radiation demands responsibility to maintain high image quality. Low doses are necessary because workers are requested to restrain the animal. Optimizing digital systems is necessary to avoid unnecessary exposure, causing the phenomenon known as dose creep. Homogeneous phantoms are widely used to optimize image quality and dose. We developed an automatic computational methodology to classify and quantify tissues (i.e., lung tissue, adipose tissue, muscle tissue, and bone in canine chest computed tomography exams. The thickness of each tissue was converted to simulator materials (i.e., Lucite, aluminum, and air. Dogs were separated into groups of 20 animals each according to weight. Mean weights were 6.5 ± 2.0 kg, 15.0 ± 5.0 kg, 32.0 ± 5.5 kg, and 50.0 ± 12.0 kg, for the small, medium, large, and giant groups, respectively. The one-way analysis of variance revealed significant differences in all simulator material thicknesses (p < 0.05 quantified between groups. As a result, four phantoms were constructed for dorsoventral and lateral views. In conclusion, the present methodology allows the development of phantoms of the canine chest and possibly other body regions and/or animals. The proposed phantom is a practical tool that may be employed in future work to optimize veterinary X-ray procedures.

  8. Phantom breast syndrome

    Directory of Open Access Journals (Sweden)

    Ramesh

    2009-01-01

    Full Text Available Phantom breast syndrome is a type of condition in which patients have a sensation of residual breast tissue and can include both non-painful sensations as well as phantom breast pain. The incidence varies in different studies, ranging from approximately 30% to as high as 80% of patients after mastectomy. It seriously affects quality of life through the combined impact of physical disability and emotional distress. The breast cancer incidence rate in India as well as Western countries has risen in recent years while survival rates have improved; this has effectively increased the number of women for whom post-treatment quality of life is important. In this context, chronic pain following treatment for breast cancer surgery is a significantly under-recognized and under-treated problem. Various types of chronic neuropathic pain may arise following breast cancer surgery due to surgical trauma. The cause of these syndromes is damage to various nerves during surgery. There are a number of assumed factors causing or perpetuating persistent neuropathic pain after breast cancer surgery. Most well-established risk factors for developing phantom breast pain and other related neuropathic pain syndromes are severe acute postoperative pain and greater postoperative use of analgesics. Based upon current evidence, the goals of prophylactic strategies could first target optimal peri-operative pain control and minimizing damage to nerves during surgery. There is some evidence that chronic pain and sensory abnormalities do decrease over time. The main group of oral medications studied includes anti-depressants, anticonvulsants, opioids, N-methyl-D-asparate receptor antagonists, mexilitine, topical lidocaine, cannabinoids, topical capsaicin and glysine antagonists. Neuromodulation techniques such as motor cortex stimulation, spinal cord stimulation, and intrathecal drug therapies have been used to treat various neuropathic pain syndromes.

  9. Healthy Parent Carers programme: development and feasibility of a novel group-based health-promotion intervention

    Directory of Open Access Journals (Sweden)

    Aleksandra J. Borek

    2018-02-01

    Full Text Available Abstract Background Parent carers of disabled children report poor physical health and mental wellbeing. They experience high levels of stress and barriers to engagement in health-related behaviours and with ‘standard’ preventive programmes (e.g. weight loss programmes. Interventions promoting strategies to improve health and wellbeing of parent carers are needed, tailored to their specific needs and circumstances. Methods We developed a group-based health promotion intervention for parent carers by following six steps of the established Intervention Mapping approach. Parent carers co-created the intervention programme and were involved in all stages of the development and testing. We conducted a study of the intervention with a group of parent carers to examine the feasibility and acceptability. Standardised questionnaires were used to assess health and wellbeing pre and post-intervention and at 2 month follow up. Participants provided feedback after each session and took part in a focus group after the end of the programme. Results The group-based Healthy Parent Carers programme was developed to improve health and wellbeing through engagement with eight achievable behaviours (CLANGERS – Connect, Learn, be Active, take Notice, Give, Eat well, Relax, Sleep, and by promoting empowerment and resilience. The manualised intervention was delivered by two peer facilitators to a group of seven parent carers. Feedback from participants and facilitators was strongly positive. The study was not powered or designed to test effectiveness but changes in measures of participants’ wellbeing and depression were in a positive direction both at the end of the intervention and 2 months later which suggest that there may be a potential to achieve benefit. Conclusions The Healthy Parent Carers programme appears feasible and acceptable. It was valued by, and was perceived to have benefited participants. The results will underpin future refinement of the

  10. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry

    Science.gov (United States)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-04-01

    Hybrid computational phantoms combine voxel-based and simplified equation-based modelling approaches to provide unique advantages and more realism for the construction of anthropomorphic models. In this work, a methodology and C++ code are developed to generate hybrid computational phantoms covering statistical distributions of body morphometry in the paediatric population. The paediatric phantoms of the Virtual Population Series (IT’IS Foundation, Switzerland) were modified to match target anthropometric parameters, including body mass, body length, standing height and sitting height/stature ratio, determined from reference databases of the National Centre for Health Statistics and the National Health and Nutrition Examination Survey. The phantoms were selected as representative anchor phantoms for the newborn, 1, 2, 5, 10 and 15 years-old children, and were subsequently remodelled to create 1100 female and male phantoms with 10th, 25th, 50th, 75th and 90th body morphometries. Evaluation was performed qualitatively using 3D visualization and quantitatively by analysing internal organ masses. Overall, the newly generated phantoms appear very reasonable and representative of the main characteristics of the paediatric population at various ages and for different genders, body sizes and sitting stature ratios. The mass of internal organs increases with height and body mass. The comparison of organ masses of the heart, kidney, liver, lung and spleen with published autopsy and ICRP reference data for children demonstrated that they follow the same trend when correlated with age. The constructed hybrid computational phantom library opens up the prospect of comprehensive radiation dosimetry calculations and risk assessment for the paediatric population of different age groups and diverse anthropometric parameters.

  11. Evolution of dosimetric phantoms

    International Nuclear Information System (INIS)

    Reddy, A.R.

    2010-01-01

    In this oration evolution of the dosimetric phantoms for radiation protection and for medical use is briefly reviewed. Some details of the development of Indian Reference Phantom for internal dose estimation are also presented

  12. Parents, peer groups, and other socializing influences.

    Science.gov (United States)

    Vandell, D L

    2000-11-01

    Three propositions that are central to J. R. Harris's group socialization theory (1995, 1998) are considered in this review. These propositions are as follows: (a) Parental behaviors have no long-term effects on children's psychological characteristics, (b) peer groups are the primary environmental influence on psychological functioning, and (c) dyadic relationships are situation-specific and do not generalize. The evidence that J. R. Harris has outlined in support of each of these propositions is reviewed, as is additional empirical research not considered by J. R. Harris. Serious limitations to each proposition are identified. The available evidence is more consistent with a model of multiple socialization agents. An expanded research agenda that permits a more definitive test of J. R. Harris's propositions and social relationship theory is proposed.

  13. Parent Group Training Programs in Juvenile Courts: A National Survey

    Science.gov (United States)

    Windell, James O.; Windell, Ellen A.

    1977-01-01

    This survey of juvenile courts across the country indicates that only one of five courts have a parent group program and few use procedures reported in the growing literature relating to changing the behavior of agressive children. (Author)

  14. The uses of an observation team with a parent support group.

    Science.gov (United States)

    O'Brien, P J

    1994-04-01

    This brief report examines the uses of an Observation Team with a Parent Support Group. In particular, attention is placed on the idea of the Observation Team acting as a Reflecting Team in the final session of the group's life. Using the Observation Team in this manner has evolved from an amalgamation of ideas from family therapy and group therapy theory.

  15. Relationship between Parenting and Cognitive Schemas in a Group of Male Adult Offenders.

    Science.gov (United States)

    Pellerone, Monica; Craparo, Giuseppe; Tornabuoni, Ylenia

    2016-01-01

    This work analyzes the correlation of retrospective ratings on parental binding with cognitive patterns in the inmates for property crimes. The participant group comprehended 248 adults men, including 130 marked out as offenders (the target group), aged between 19 and 70, currently serving sentences in the Cavadonna prison in Siracusa, and 118 marked out as non-offenders (the control group), aged between 20 and 70, living in Siracusa (Sicily). The instruments used were the Parental Bonding Instrument (PBI), and the Young Schema Questionnaire-3 (YSQ). The preliminary analysis showed a high percentage of offenders who experienced an affectionate constraint parenting. Offenders scored significantly higher than the non-offenders on the level of paternal control and the YSQ subscales. The study underlines the influence of maternal care on most of the cognitive schemas, and the role of father's control on the tendency to social isolation and defectiveness in the offenders.

  16. The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

    International Nuclear Information System (INIS)

    Johnson, Perry B.; Geyer, Amy; Borrego, David; Ficarrotta, Kayla; Johnson, Kevin; Bolch, Wesley E.

    2011-01-01

    Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences

  17. 3D Printing Openable Imaging Phantom Design

    International Nuclear Information System (INIS)

    Kim, Myoung Keun; Won, Jun Hyeok; Lee, Seung Wook

    2017-01-01

    The purpose of this study is to design an openable phantom that can replace the internal measurement bar used for contrast comparison in order to increase the efficiency of manufacturing imaging phantom used in the medical industry and to improve convenience using 3D printer. Phantom concept design, 3D printing, and Image reconstruction were defined as the scope of the thesis. Also, we study metal artifact reduction with openable phantom. We have designed a Openable phantom using 3D printing, and have investigated metal artifact reduction after inserting a metallic material inside the phantom. The openable phantom can be adjusted at any time to suit the user's experiment and can be easily replaced and useful.

  18. The subresolution DaTSCAN phantom: a cost-effective, flexible alternative to traditional phantom technology.

    Science.gov (United States)

    Taylor, Jonathan C; Vennart, Nicholas; Negus, Ian; Holmes, Robin; Bandmann, Oliver; Lo, Christine; Fenner, John

    2018-03-01

    The Alderson striatal phantom is frequently used to assess I-FP-CIT (Ioflupane) image quality and to test semi-quantification software. However, its design is associated with a number of limitations, in particular: unrealistic image appearances and inflexibility. A new physical phantom approach is proposed on the basis of subresolution phantom technology. The design incorporates thin slabs of attenuating material generated through additive manufacturing, and paper sheets with radioactive ink patterns printed on their surface, created with a conventional inkjet printer. The paper sheets and attenuating slabs are interleaved before scanning. Use of thin layers ensures that they cannot be individually resolved on reconstructed images. An investigation was carried out to demonstrate the performance of such a phantom in producing simplified I-FP-CIT uptake patterns. Single photon emission computed tomography imaging was carried out on an assembled phantom designed to mimic a healthy patient. Striatal binding ratio results and linear striatal dimensions were calculated from the reconstructed data and compared with that of 22 clinical patients without evidence of Parkinsonian syndrome, determined from clinical follow-up. Striatal binding ratio results for the fully assembled phantom were: 3.1, 3.3, 2.9 and 2.6 for the right caudate, left caudate, right putamen and right caudate, respectively. All were within two SDs of results derived from a cohort of clinical patients. Medial-lateral and anterior-posterior dimensions of the simulated striata were also within the range of values seen in clinical data. This work provides the foundation for the generation of a range of more clinically realistic, physical phantoms.

  19. The Effectiveness of a Group Counseling Program on the Mental Health of Parents of Hearing Impaired Children

    Directory of Open Access Journals (Sweden)

    Dr. Mahshid Foroughan

    2007-12-01

    Full Text Available Background and Aim: Most of the studies indicates that the parents of the hearing impaired children show many mental health problems after the diagnosis of their children's hearing impairment. Counselling with the parents of the hearing impaired children is one of the most important goals of any early intervention program. This paper describes a study to determine the effectiveness of a group counselling programme for parents of hearing impaired children. Materials and Method: It was a semi-experimental study with a single group pretest-post test design. The participants were all the parents of hearing impaired children attending in an early intervention center. First the parents' mental health were assessed.Then the group counselling program was implemented. Program has involved six weekly 1.5 hour sessions. The format of each session included both lecture presentation and group discussion using cognitive behavioral procedure. Subjects were assessed before and immediately after group therapy by means of General Health Questionnaire(GHQ and Symptom Check List 90 (SCL-90 questionnaires. Resuts: The first part of the project had shown that over the half of the parents had considerable psychosocial morbidity. Comparisons showed a significant reduction from pretreatment to posttreatment in depression, anxiety and most of other psychological problems. Conclusion: The study supports the effectiveness of group therapy programs in the treatment of parents of hearing impaired children. Concerning the progress of early detection programs for the children's hearing impairment more studies should be done in the field of counseling with their parents.

  20. Cognitive behavioural group treatment for Chinese parents with children with developmental disabilities in Melbourne, Australia: an efficacy study.

    Science.gov (United States)

    Wong, Fu Keung Daniel; Poon, Ada

    2010-08-01

    This study attempted to test the efficacy of a culturally attuned cognitive behavioural therapy (CBT) group for Chinese parents with children with developmental disabilities at risk of developing mental health problems in Melbourne, Australia. It was hypothesized that the participants in the experimental group would have less parenting stress and fewer dysfunctional attitudes, rules, and values, and better mental health and quality of life than the participants in the control group post-test. A total of 58 participants were randomly assigned into CBT and waiting list control groups. While ANCOVAs were used to compare the differences in General Health Questionnaires-12 (GHQ-12), Parenting Stress Index- Parent Domain (PSI-PD), Quality of Life Enjoyment and Satisfaction Questionnnaire-18 (Q-LES-Q-18) and Dysfunctional Attitude Scale (DAS) between participants of the experiemental and control groups, effect size statistics were performed to measure the magnitude of changes in the above instruments at post treatment. After ten weeks of treatment, the participants in the CBT group showed significant improvement in GHQ-12, Parenting Stress Index (PSI)-Parent Domain and Q-LES-Q-18 scores, but not in DAS scores. The effect size statistics revealed large differences in GHQ-12, PSI-Parent Domain and Q-LES-Q-18 scores between the participants in the experimental and control groups at post-treatment. When a GHQ score of 4 or greater was used as the recommended cut-off score, about 89% and 10% of the participants in the experimental and control groups, respectively, were classified as not at-risk cases at post-treatment. The initial findings suggest that a culturally attuned CBT group may help Chinese parents with children with developmental disabilities to reduce their parenting stress and improve their general mental health and quality of life.

  1. Group Cognitive Behavioral Treatment for Parents and Children At-Risk for Physical Abuse: An Initial Study

    Science.gov (United States)

    Runyon, Melissa K.; Deblinger, Esther; Steer, Robert A.

    2010-01-01

    To compare the relative efficacy of two types of group cognitive-behavioral therapy for treating the traumatized child and at-risk or offending parent in cases of child physical abuse (CPA), 24 parents and their children were treated with Combined Parent-Child Cognitive Behavioral Therapy (CPC-CBT) and 20 parents were treated with Parent-Only CBT.…

  2. Parental Homework Completion and Treatment Knowledge during Group Parent-Child Interaction Therapy

    Science.gov (United States)

    Ros, Rosmary; Graziano, Paulo A.; Hart, Katie C.

    2017-01-01

    The purpose of this study was to examine how parental homework completion, session attendance, and treatment knowledge influenced parenting practices and confidence in using learned skills during behavioral parent training (BPT). Parents of 54 preschoolers (M[subscript age] = 5.07, 82% Hispanic/Latino) with externalizing behavior problems…

  3. Technique for evaluation of spatial resolution and microcalcifications in digital and scanned images of a standard breast phantom

    International Nuclear Information System (INIS)

    Santana, Priscila do C.; Gomes, Danielle S.; Oliveira, Marcio A.; Oliveira, Paulo Marcio C. de; Meira-Belo, Luiz C.; Nogueira-Tavares, Maria S.

    2011-01-01

    In this work, an automated methodology to evaluate digital and scanned images of a standard phantom (Phantom Mama) was studied. The Phantom Mama was used as an important tool to check the quality of mammographs. The scanned images were digitized using a ScanMaker 9800XL, with resolution of 900 dpi. The aim of this work is to test an automatic methodology for evaluation of spatial resolution and microcalcifications group of phantom mama images acquired with the same parameters in the same equipment. In order to analyze the images we have used the ImageJ software (in Java) which is public domain. We have used the Fast Fourier transform technique to evaluate the spatial resolution and used the ImageJ function Subtract Background and the Light Background plus Sliding Paraboloid on the evaluation of the five groups of microcalcifications on the breast phantom to assess the viability of using automated methods for both types of images. The methodology was adequate for evaluated the microcalcifications group and the spatial resolution in scanned and digital images, but the Phantom Mama doesn't provide sufficient parameters to evaluate the spatial resolution in this images. (author)

  4. Relationship between parenting and cognitive schemas in a group of male adult offenders

    Directory of Open Access Journals (Sweden)

    Monica ePellerone

    2016-03-01

    Full Text Available This work analyzes the correlation of retrospective ratings on parental binding with cognitive patterns in the inmates for property crimes. The participant group comprehended 248 adults men, including 130 marked out as offenders (the experimental group, aged between 19 and 70, currently serving sentences in the Cavadonna prison in Siracusa, and 118 marked out as non-offenders (the control group, aged between 20 and 70, living in Siracusa (Sicily.The instruments used were the Parental Bonding Instrument (PBI, and the Young Schema Questionnaire-3 (YSQ. The preliminary analysis showed an high percentage of offenders who experienced an affectionate constraint parenting. Offenders scored significantly higher than the non-offenders on the level of paternal control and the YSQ subscales. The study underlines the influence of maternal care on most of the cognitive schemas, and the role of father’s control on the tendency to social isolation and defectiveness in the offenders.

  5. The effectiveness of a Group Triple P with Chinese parents who have a child with developmental disabilities: a randomized controlled trial.

    Science.gov (United States)

    Leung, Cynthia; Fan, Angel; Sanders, Matthew R

    2013-03-01

    The study examined the effectiveness of Group Triple P, a Level 4 variant of the Triple P multilevel system of parenting support, with Chinese parents who had a preschool aged child with a developmental disability, using randomized controlled trial design. Participants (Intervention group: 42; Waitlist Control group: 39) completed measures on child behaviour, parental stress, dysfunctional discipline styles and parental conflict before and after program completion by the Intervention group. Intervention group participants also completed these same measures six months after program completion. Compared to the Waitlist Control group, parents receiving Group Triple P reported significantly lower levels of child behaviour problems, parental stress, dysfunctional discipline style and parental conflict scores. The Intervention group participants maintained their gains six months after program completion. The results provided promising evidence for the Level 4 Group Triple P as an effective intervention program for Chinese parents who have preschool aged children with developmental disabilities. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Parenting Predictors of Early-Adolescents' Health Behaviors: Simultaneous Group Comparisons across Sex and Ethnic Groups

    Science.gov (United States)

    Windle, Michael; Brener, Nancy; Cuccaro, Paula; Dittus, Patricia; Kanouse, David E.; Murray, Nancy; Wallander, Jan; Schuster, Mark A.

    2010-01-01

    The purpose of this study was to evaluate the invariance of predictive relations across early-adolescent sex and ethnic groups regarding parenting factors and externalizing and internalizing problems and victimization. Data (n = 598; 54% female) from a triethnic (Hispanic, non-Hispanic white, and non-Hispanic black) probability sample of fifth…

  7. Parental Smoking and Adult Offspring's Smoking Behaviors in Ethnic Minority Groups: An Intergenerational Analysis in the HELIUS Study.

    Science.gov (United States)

    Ikram, Umar Z; Snijder, Marieke B; Derks, Eske M; Peters, Ron J G; Kunst, Anton E; Stronks, Karien

    2017-06-21

    To understand smoking behaviors among ethnic minority groups, studies have largely focused on societal factors, with little attention to family influences. Yet studies among majority groups have identified parental smoking as an important risk factor. It is unknown whether this applies to ethnic minority groups. We investigated the association between parental smoking and adult offspring's smoking behaviors among ethnic minority groups with an immigrant background. We used data from the Healthy Life in an Urban Setting study from Amsterdam (the Netherlands) from January 2011 to December 2015. The sample consisted of 2184 parent-offspring pairs from South-Asian Surinamese, African Surinamese, Turkish, Moroccan, and Ghanaian origin. We collected self-reported smoking data: current status, duration of exposure to parental smoking, number of daily cigarettes, heavy smoking ( > 10 cigarettes/day), and nicotine dependency (using the Fagerström Test). Analyses were stratified by offspring's age, cohabitation with parent, education (parent/offspring), offspring's cultural orientation, and gender concordance within pairs. Logistic regression was used. Overall, parental smoking was associated with offspring's smoking behaviors (eg, current smoking: odds ratio 2.33; 95% confidence interval 1.79-3.03), with little ethnic variation. We found dose-response associations between exposure to parental smoking and offspring's smoking. The associations were similar across different strata but stronger in gender-concordant pairs (3.16; 2.12-4.51 vs. 1.73; 1.15-2.59 in gender-discordant pairs; p-value for interaction .017). Parental smoking is associated with offspring's smoking behaviors in ethnic minority groups across different strata but particularly in gender-concordant pairs. Similar to majority groups, family influences matter to smoking behaviors in ethnic minority groups. Our findings have deepened our understanding of smoking behaviors among ethnic minority groups. Future

  8. Group parent-child interaction therapy: A randomized control trial for the treatment of conduct problems in young children.

    Science.gov (United States)

    Niec, Larissa N; Barnett, Miya L; Prewett, Matthew S; Shanley Chatham, Jenelle R

    2016-08-01

    Although efficacious interventions exist for childhood conduct problems, a majority of families in need of services do not receive them. To address problems of treatment access and adherence, innovative adaptations of current interventions are needed. This randomized control trial investigated the relative efficacy of a novel format of parent-child interaction therapy (PCIT), a treatment for young children with conduct problems. Eighty-one families with 3- to 6-year-old children (71.6% boys, 85.2% White) with diagnoses of oppositional defiant or conduct disorder were randomized to individual PCIT (n = 42) or the novel format, Group PCIT. Parents completed standardized measures of children's conduct problems, parenting stress, and social support at intake, posttreatment, and 6-month follow-up. Therapist ratings, parent attendance, and homework completion provided measures of treatment adherence. Throughout treatment, parenting skills were assessed using the Dyadic Parent-Child Interaction Coding System. Parents in both group and individual PCIT reported significant improvements from intake to posttreatment and follow-up in their children's conduct problems and adaptive functioning, as well as significant decreases in parenting stress. Parents in both treatment conditions also showed significant improvements in their parenting skills. There were no interactions between time and treatment format. Contrary to expectation, parents in Group PCIT did not experience greater social support or treatment adherence. Group PCIT was not inferior to individual PCIT and may be a valuable format to reach more families in need of services. Future work should explore the efficiency and sustainability of Group PCIT in community settings. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Group Parent-Child Interaction Therapy: A Randomized Control Trial for the Treatment of Conduct Problems in Young Children

    Science.gov (United States)

    Niec, Larissa N.; Barnett, Miya L.; Prewett, Matthew S.; Shanley, Jenelle

    2016-01-01

    Objective Although efficacious interventions exist for childhood conduct problems, a majority of families in need of services do not receive them. To address problems of treatment access and adherence, innovative adaptations of current interventions are needed. This randomized control trial investigated the relative efficacy of a novel format of parent-child interaction therapy (PCIT), a treatment for young children with conduct problems. Methods Eighty-one families with three- to six-year-old children (71.6% male; 85.2% Caucasian) with diagnoses of oppositional defiant or conduct disorder were randomized to individual PCIT (n = 42) or the novel format, group PCIT. Parents completed standardized measures of children’s conduct problems, parenting stress, and social support at intake, posttreatment, and six-month follow-up. Therapist ratings, parent attendance, and homework completion provided measures of treatment adherence. Throughout treatment, parenting skills were assessed using the Dyadic Parent-Child Interaction Coding System. Results Parents in both group and individual PCIT reported significant improvements from intake to posttreatment and follow-up in their children’s conduct problems and adaptive functioning, as well as significant decreases in parenting stress. Parents in both treatment conditions also showed significant improvements in their parenting skills. There were no interactions between time and treatment format. Contrary to expectation, parents in group PCIT did not experience greater social support or treatment adherence. Conclusions Group PCIT was not inferior to individual PCIT and may be a valuable format to reach more families in need of services. Future work should explore the efficiency and sustainability of group PCIT in community settings. PMID:27018531

  10. A randomized controlled trial of a brief versus standard group parenting program for toddler aggression.

    Science.gov (United States)

    Tully, Lucy A; Hunt, Caroline

    2017-05-01

    Physical aggression (PA) in the toddler years is common and developmentally normal, however, longitudinal research shows that frequent PA is highly stable and associated with long-term negative outcomes. Significant research has demonstrated the efficacy of parenting interventions for reducing externalizing behavior in children yet their typical length may overburden families, leading to low participation rates and high attrition rates. To increase the reach of parenting interventions and impact on the prevalence of externalizing behavior problems, brief interventions are needed. This RCT compared a standard (8 session) group Triple P to a brief (3 session) discussion group and a waitlist control for reducing toddler PA, dysfunctional parenting and related aspects of parent functioning. Sixty-nine self-referred families of toddlers with PA were randomized to the respective conditions. At post-assessment, families in the standard intervention had significantly lower levels of observed child aversive behavior, mother reports of PA and dysfunctional parenting, and higher levels of mother- and partner-rated behavioral self-efficacy than the waitlist control. Families in the standard intervention also had significantly lower levels mother-rated dysfunctional parenting than the brief intervention, and the brief intervention had significantly lower levels of mother-rated dysfunctional parenting than waitlist. There were no significant group differences at post-assessment for measures of parental negative affect or satisfaction with the partner relationship. By 6 month follow-up, families in the brief and standard intervention did not differ significantly on any measure. The implications of the findings to delivery of brief parenting interventions are discussed. Aggr. Behav. 43:291-303, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Functional Assessment Based Parent Intervention in Reducing Children’s Challenging Behaviors: Exploratory Study of Group Training

    OpenAIRE

    Angel Fettig; Michaelene M. Ostrosky

    2014-01-01

    This study examined the effects of group parent training on children’s challenging behaviors in home settings. Eight parents of young children with challenging behaviors were trained in a large group setting on using functional assessment to design interventions that fit the strengths and needs of individual families. The training included information sharing and collaborating with parents on designing functional-assessment based interventions. An Interrupted Time Series Design was used to ex...

  12. A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Funama, Yoshinori [Kumamoto University, Department of Radiological Sciences, School of Health Sciences, Kumamoto (Japan); Awai, Kazuo; Nakayama, Yoshiharu; Liu, Da; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Miyazaki, Osamu; Goto, Taiga [Hitachi Medical Corporation, Tokyo (Japan); Hori, Shinichi [Gate Tower Institute of Image Guided Therapy, Osaka (Japan)

    2006-04-15

    The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detector CT. We added an inhomogeneous texture to the simulated liver by referring to CT images of chronically damaged human livers. The mean CT number of the simulated liver was 60 HU and we added numerous 5-to 10-mm structures with 60{+-}10 HU/mm. To mimic liver tumors we added nodules measuring 8, 10, and 12 mm in diameter with CT numbers of 60{+-}10, 60{+-}15, and 60{+-}20 HU. Five radiologists visually evaluated similarity of the texture of the computer-simulated liver phantom and a real human liver to confirm the appropriateness of the virtual liver images using a five-point scale. The total score was 44 in two radiologists, and 42, 41, and 39 in one radiologist each. They evaluated that the textures of virtual liver were comparable to those of human liver. Our computer-simulated liver phantom is a promising tool for the evaluation of the image quality and diagnostic performance of hepatic CT imaging. (orig.)

  13. Individual and group-based parenting programmes for the treatment of physical child abuse and neglect.

    Science.gov (United States)

    Barlow, J; Johnston, I; Kendrick, D; Polnay, L; Stewart-Brown, S

    2006-07-19

    Child physical abuse and neglect are important public health problems and recent estimates of their prevalence suggest that they are considerably more common than had hitherto been realised. Many of the risk factors for child abuse and neglect are not amenable to change in the short term. Intervening to change parenting practices may, however, be important in its treatment. Parenting programmes are focused, short-term interventions aimed at improving parenting practices in addition to other outcomes (many of which are risk factors for child abuse e.g. parental psychopathology, and parenting attitudes and practices), and may therefore be useful in the treatment of physically abusive or neglectful parents. To assess the efficacy of group-based or one-to-one parenting programmes in addressing child physical abuse or neglect. A range of biomedical and social science databases were searched including MEDLINE, EMBASE, CINAHL, PsychINFO, Sociofile, Social Science Citation Index, ASSIA, the Cochrane Library, Campbell Library (including SPECTR and CENTRAL), National Research Register (NRR) and ERIC, from inception to May 2005. Only randomised controlled trials or randomised studies that compared two treatments were included. Studies had to include at least one standardised instrument measuring some aspect of abusive or neglectful parenting. In the absence of studies using objective assessments of child abuse, studies reporting proxy measures of abusive parenting were included. Only studies evaluating the effectiveness of standardised group-based or one-to-one parenting programmes aimed at the treatment of physical child abuse or neglect were included. Studies were also only eligible for inclusion if they had targeted parents of children aged 0-19 years who had been investigated for physical abuse or neglect. The treatment effect for each outcome in each study was standardised by dividing the mean difference in post-intervention scores for the intervention and treatment

  14. Effect of phantom voxelization in CT simulations

    International Nuclear Information System (INIS)

    Goertzen, Andrew L.; Beekman, Freek J.; Cherry, Simon R.

    2002-01-01

    In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 10 3 -10 7 photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel

  15. Development and Implementation of a Psychoeducational Group for Ghanaian Adolescents Experiencing Parental Divorce

    Science.gov (United States)

    Nkyi, Anthony K.

    2015-01-01

    This article presents development and informal assessment of a 10-week psychoeducational program designed for 8 adolescent group members experiencing parental divorce in a rural community in Ghana. Group design, cultural considerations, program implementation, and impacts are described. The literature review pertaining to group work as an…

  16. Something for Everyone: Benefits of Mixed-Age Grouping for Children, Parents, and Teachers.

    Science.gov (United States)

    Theilheimer, Rachel

    1993-01-01

    Discusses the benefits of mixed-age grouping for children's social and cognitive development and reservations parents sometimes have about mixed-age groupings. Also discusses issues that teachers need to consider when implementing mixed-age groups: children's personal care routines; furnishings; children's language, motor, creative, and social…

  17. A comparison of digital and screen-film mammography using quality control phantoms

    International Nuclear Information System (INIS)

    Undrill, Peter E.; O'Kane, Arlene D.; Gilbert, Fiona J.

    2000-01-01

    AIM: To compare the performance of a direct digital mammography system with normal-view and magnified-view conventional screen-film methods using quality control phantoms. MATERIALS AND METHODS: Using a Siemens Mammomat [reg] 3000 and an Opdima [reg] digital spot imaging and biopsy attachment, film and direct digital images of two phantoms [DuPont and TOR (MAM)] were obtained under normal operating conditions. These were assessed by three groups of observers with differing expertise -- radiologists, radiographers and medical physicists. Each observer was asked to compare the direct digital image with films taken in standard view and magnified view, providing scores for object visibility and confidence. For the digital images, observers were allowed to vary the image presentation parameters. RESULTS: Both phantoms showed that overall the direct digital view and the magnified view film performed significantly better (P < 0.05) than standard view film. For certain small or low contrast objects the differences became very highly significant (P < 0.001). CONCLUSION: Only the TOR (MAM) phantom showed any significant difference between digital and magnified modalities, with magnified views performing better for fine, faint filaments and digital acquisition better for low contrast objects. Almost no difference existed between the three observer groups. Undrill, P.E. (2000). Clinical Radiology 53, 782-790

  18. Authoritative parenting and parental stress in parents of pre-school and older children with developmental disabilities.

    Science.gov (United States)

    Woolfson, L; Grant, E

    2006-03-01

    Rearing a child with a developmental disability is associated with increased parental stress. Theories of stress and adjustment and bi-directional theories of child development suggest that parenting could influence these negative outcomes. Relationships between parenting approaches and stress in parents of children with developmental disabilities (DD) (N = 53) were examined across two age groups, 3-5 years and 9-11 years and compared with a contrast group of typically developing children (TD) (N = 60). Measures used were the Parenting Stress Index-Short Form and Rickel and Biasatti's modification of Block's Child Rearing Practices Report, classified into Baumrind's parenting styles using Reitman and Gross's method. Parents in the older DD group used Authoritative parenting less than parents in the younger DD group, while the opposite developmental pattern was seen in the TD group. Multivariate analysis of variance showed a significant group x parenting style interaction for Parental Distress, Parent-Child Dysfunctional Interaction and Difficult Child. Stress measures were higher for the DD group and seemed to be associated with Authoritative parenting approaches, an effect that was not observed in the TD group. Findings suggest that the well-established effect of group on stress may be moderated by parenting style. Authoritative parenting may be highly stressful for parents of children with DD to implement, resulting in a decrease in its use across the two age groups.

  19. The Japanese adult, child and infant phantoms

    International Nuclear Information System (INIS)

    Cristy, Mark; Egbert, Stephen D.

    1987-01-01

    The mathematical phantom for adult Japanese atomic-bomb survivors is a modification of the 57-kg ORNL (Oak Ridge National Laboratory) phantom for Western 15-year-old males and adult females. For younger Japanese survivors mathematical phantoms were similarly modified from the 18 and 9 kg ORNL phantoms for Western 5- and 1-year-olds, respectively. To make the phantom correspond more closely with dimensions and organ sizes recommended for Japanese adults by Maruyama and coworkers (cf E184), changes were made in the size of the lungs, the pancreas, the thyroid, and the testes and in the length of the legs. Also, the head-and-neck region was modified to improve the dose estimates for the thyroid from external radiation, after the ideas of Nagarajan et al. The arms were separated from the trunk to represent more accurately the shielding by the phantom in external exposures. Furthermore, provisions were made to provide a phantom in a kneeling posture. The elemental composition of the tissues was changed to that given by Kerr. The resulting phantom is slightly smaller in mass (55 kg). Details of these changes are given

  20. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    International Nuclear Information System (INIS)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih

    2011-01-01

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average ± standard deviation CBT and breast glandularity in this study were 4.2 ± 1.0 cm and 54% ± 23%, respectively. The average equivalent PMMA thickness was 4.0 ± 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  1. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China); Department of Radiology, Cheng Hsin General Hospital, 45 Cheng Hsin Street, Pai-Tou District, Taipei 11220, Taiwan (China); Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan (China); Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China)

    2011-07-15

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average {+-} standard deviation CBT and breast glandularity in this study were 4.2 {+-} 1.0 cm and 54% {+-} 23%, respectively. The average equivalent PMMA thickness was 4.0 {+-} 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  2. Let's face it: patient and parent perspectives on incorporating a Facebook group into a multidisciplinary weight management program.

    Science.gov (United States)

    Woolford, Susan J; Esperanza Menchaca, Alicia D M; Sami, Areej; Blake, Natalie

    2013-08-01

    Social media may have the potential to enhance weight management efforts. However, the acceptability of incorporating this entity into pediatrics is unknown. The objective of this project was to explore patients' and parents' perspectives about developing a Facebook group as a component of a pediatric weight management program. Semistructured interviews were performed between September, 2011, and February, 2012, with patients and parents in a multidisciplinary weight management program. Interviews explored participants' perceptions of potential benefits, concerns, and preferences related to a program-specific Facebook group. Transcripts were reviewed and themes identified. The study concluded when thematic saturation was achieved. Participants (n=32) were largely enthusiastic about the idea of a program-specific Facebook group for adolescents. Most preferred a secret group, where only participants would know of the group's existence or group members' identity. No parents expressed concern about security or privacy related to a program-specific Facebook group; one parent expressed concern about undesirable advertisements. Participants endorsed a variety of ideas for inclusion on the page, including weight loss tips, live chats with providers, quizzes, and an incentive system where participants could gain points for making healthy choices. Many parents requested a separate parent-focused page, an idea that was supported by the adolescents. This study suggests that participants perceive potential benefits from incorporating social media interventions into pediatric weight management efforts. Privacy and security issues do not appear to be major parental concerns. Future work should explore the impact of program-specific social media interventions on outcomes for patients in weight management programs.

  3. A statistically defined anthropomorphic software breast phantom

    International Nuclear Information System (INIS)

    Lau, Beverly A.; Reiser, Ingrid; Nishikawa, Robert M.; Bakic, Predrag R.

    2012-01-01

    Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm) 3 voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise (β = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 × 3 boxcar kernel and up-sampled to (0.1 mm) 3 voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent β from 25.6 × 25.6 mm 2 regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for β (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. β values for this new phantom are comparable

  4. Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2015-07-01

    Full Text Available Introduction Based on Task Group No. 43 (TG-43U1 recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods TG-43 parameters of low- and high-energy brachytherapy sources (i.e., Pd-103, I-125 and Cs-137 were obtained in different phantoms, using Monte Carlo simulations. The brachytherapy sources were simulated at the center of different phantoms including water, solid water, poly(methyl methacrylate, polystyrene and polyethylene. Dosimetric parameters such as dose rate constant, radial dose function and anisotropy function of each source were compared in different phantoms. Then, conversion factors were obtained to make phantom parameters equivalent to those of water. Results Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water. Conclusion Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water.

  5. Development of a phantom to test fully automated breast density software – A work in progress

    International Nuclear Information System (INIS)

    Waade, G.G.; Hofvind, S.; Thompson, J.D.; Highnam, R.; Hogg, P.

    2017-01-01

    Objectives: Mammographic density (MD) is an independent risk factor for breast cancer and may have a future role for stratified screening. Automated software can estimate MD but the relationship between breast thickness reduction and MD is not fully understood. Our aim is to develop a deformable breast phantom to assess automated density software and the impact of breast thickness reduction on MD. Methods: Several different configurations of poly vinyl alcohol (PVAL) phantoms were created. Three methods were used to estimate their density. Raw image data of mammographic images were processed using Volpara to estimate volumetric breast density (VBD%); Hounsfield units (HU) were measured on CT images; and physical density (g/cm 3 ) was calculated using a formula involving mass and volume. Phantom volume versus contact area and phantom volume versus phantom thickness was compared to values of real breasts. Results: Volpara recognized all deformable phantoms as female breasts. However, reducing the phantom thickness caused a change in phantom density and the phantoms were not able to tolerate same level of compression and thickness reduction experienced by female breasts during mammography. Conclusion: Our results are promising as all phantoms resulted in valid data for automated breast density measurement. Further work should be conducted on PVAL and other materials to produce deformable phantoms that mimic female breast structure and density with the ability of being compressed to the same level as female breasts. Advances in knowledge: We are the first group to have produced deformable phantoms that are recognized as breasts by Volpara software. - Highlights: • Several phantoms of different configurations were created. • Three methods to assess phantom density were implemented. • All phantoms were identified as breasts by the Volpara software. • Reducing phantom thickness caused a change in phantom density.

  6. Parenting and Preschool Child Development: Examination of Three Low-Income U.S. Cultural Groups

    Science.gov (United States)

    Whiteside-Mansell, Leanne; Bradley, Robert H.; McKelvey, Lorraine

    2009-01-01

    We examined the impact of parenting behaviors on preschool children's social development in low-income families from three cultural groups: European American (n = 286), African American (n = 399), and Hispanic American (n = 164) using Spanish as the primary language in the home. Observed parenting behaviors of stimulation, responsivity, and…

  7. An improved Virtual Torso phantom

    International Nuclear Information System (INIS)

    Kramer, Gary H; Crowley, Paul

    2000-01-01

    The virtual phantom that was previously designed by the Human Monitoring Laboratory had some limitations. It contained no sternum and the ribs extended all the way round the torso, whereas in reality the central part of the chest is covered with a mixture of cartilage (ribs) and bone (sternum). The ribs were located below the chest wall which added to the thickness of the chest wall. The lungs did not touch the inner surface of the chest wall along their length due to the differences in curvature between the ellipsoidal lungs and the ellipsoidal cylinder that defined the torso. As a result there was extra intervening tissue between the lungs and the chest wall. This was shown to have a noticeable effect on the simulation of low energy photons. The virtual phantom has been redesigned and comparison of measured and calculated counting efficiencies shows that it is a good representation of both of LLNL or JAERI at all photon energies measured. The redesigned virtual phantom agrees to within 11% of the torsos' counting efficiency over the energy range 17 - 240 keV. Before modification, the virtual phantom's counting efficiency was a of factor three lower at 17 keV and a factor of two lower at 20 keV; now it is within 5% at 17 keV and within 10% at 20 keV. This phantom can now be reliably used to simulate lung counting. The virtual phantom still contains no sternum and the ribs extend all the way round the torso, whereas in reality the central part of the chest is covered with cartilage (ribs) and bone (sternum). However, the above results indicate that this is not a major flaw in the design of the virtual phantom, as agreement between the Monte Carlo results and experimental data is good. (author)

  8. A Preliminary Investigation of Toughlove: Assertiveness and Support in a Parents' Self-Help Group.

    Science.gov (United States)

    Klug, Wayne

    This study examined Toughlove, the controversial self-help organization for parents and out-of-control adolescents. Six small group Toughlove meetings containing an average of 8 members for each were observed, and questionnaires were completed by 75 Toughlove parents from 8 states. Variables examined include the roles of empathy, assertiveness…

  9. Phantom dosimetry at 15 MV conformal radiation therapy

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio P.R.; Dias, Humberto G.

    2013-01-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  10. Phantom dosimetry at 15 MV conformal radiation therapy

    International Nuclear Information System (INIS)

    Thompson, Larissa; Campos, Tarcisio P.R.

    2015-01-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  11. Comparison of methods for individualized astronaut organ dosimetry: Morphometry-based phantom library versus body contour autoscaling of a reference phantom

    Science.gov (United States)

    Sands, Michelle M.; Borrego, David; Maynard, Matthew R.; Bahadori, Amir A.; Bolch, Wesley E.

    2017-11-01

    One of the hazards faced by space crew members in low-Earth orbit or in deep space is exposure to ionizing radiation. It has been shown previously that while differences in organ-specific and whole-body risk estimates due to body size variations are small for highly-penetrating galactic cosmic rays, large differences in these quantities can result from exposure to shorter-range trapped proton or solar particle event radiations. For this reason, it is desirable to use morphometrically accurate computational phantoms representing each astronaut for a risk analysis, especially in the case of a solar particle event. An algorithm was developed to automatically sculpt and scale the UF adult male and adult female hybrid reference phantom to the individual outer body contour of a given astronaut. This process begins with the creation of a laser-measured polygon mesh model of the astronaut's body contour. Using the auto-scaling program and selecting several anatomical landmarks, the UF adult male or female phantom is adjusted to match the laser-measured outer body contour of the astronaut. A dosimetry comparison study was conducted to compare the organ dose accuracy of both the autoscaled phantom and that based upon a height-weight matched phantom from the UF/NCI Computational Phantom Library. Monte Carlo methods were used to simulate the environment of the August 1972 and February 1956 solar particle events. Using a series of individual-specific voxel phantoms as a local benchmark standard, autoscaled phantom organ dose estimates were shown to provide a 1% and 10% improvement in organ dose accuracy for a population of females and males, respectively, as compared to organ doses derived from height-weight matched phantoms from the UF/NCI Computational Phantom Library. In addition, this slight improvement in organ dose accuracy from the autoscaled phantoms is accompanied by reduced computer storage requirements and a more rapid method for individualized phantom generation

  12. Developing a parent-professional team leadership model in group work: work with families with children experiencing behavioral and emotional problems.

    Science.gov (United States)

    Ruffolo, Mary C; Kuhn, Mary T; Evans, Mary E

    2006-01-01

    Building on the respective strengths of parent-led and professional-led groups, a parent-professional team leadership model for group interventions was developed and evaluated for families of youths with emotional and behavioral problems. The model was developed based on feedback from 26 parents in focus group sessions and recommendations from mental health professionals in staff meetings. Evaluations of an implementation of the model in a support, empowerment, and education group intervention (S.E.E. group) have demonstrated the usefulness of this approach in work with families of children with behavioral and emotional problems. This article discusses the challenges of instituting the model in an S.E.E. group. It explores how parents and professionals build the team leadership model and the strengths of this approach in working with parents of youths with serious emotional disturbances.

  13. Composition of MRI phantom equivalent to human tissues

    International Nuclear Information System (INIS)

    Kato, Hirokazu; Kuroda, Masahiro; Yoshimura, Koichi; Yoshida, Atsushi; Hanamoto, Katsumi; Kawasaki, Shoji; Shibuya, Koichi; Kanazawa, Susumu

    2005-01-01

    We previously developed two new MRI phantoms (called the CAG phantom and the CAGN phantom), with T1 and T2 relaxation times equivalent to those of any human tissue at 1.5 T. The conductivity of the CAGN phantom is equivalent to that of most types of human tissue in the frequency range of 1 to 130 MHz. In this paper, the relaxation times of human tissues are summarized, and the composition of the corresponding phantoms are provided in table form. The ingredients of these phantoms are carrageenan as the gelling agent, GdCl 3 as a T1 modifier, agarose as a T2 modifier, NaCl (CAGN phantom only) as a conductivity modifier, NaN 3 as an antiseptic, and distilled water. The phantoms have T1 values of 202-1904 ms and T2 values of 38-423 ms when the concentrations of GdCl 3 and agarose are varied from 0-140 μmol/kg, and 0%-1.6%, respectively, and the CAGN phantom has a conductivity of 0.27-1.26 S/m when the NaCl concentration is varied from 0%-0.7%. These phantoms have sufficient strength to replicate a torso without the use of reinforcing agents, and can be cut by a knife into any shape. We anticipate the CAGN phantom to be highly useful and practical for MRI and hyperthermia-related research

  14. Parental decisional strategies regarding HPV vaccination before media debates: a focus group study

    NARCIS (Netherlands)

    Hofman, R.; Empelen, P. van; Vogel, I.; Raat, H.; Ballegooijen, M. van; Korfage, I.J.

    2013-01-01

    Before the introduction of the human papillomavirus (HPV) vaccine, decisional strategies and factors that could guide HPV vaccination intentions were explored. The authors conducted 4 focus group discussions with 36 parents of children 8-15 years of age. Three groups consisted primarily of Dutch

  15. Performance testing of medical US equipment using US phantom (ATS-539)

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Kwon, Deok Moon

    2014-01-01

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment

  16. Performance testing of medical US equipment using US phantom (ATS-539)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Hyung [Daegu Branch, Korea Association of Health Promotion, Daegu (Korea, Republic of); Kwon, Deok Moon [Dept. of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

  17. Parental presence on neonatal intensive care unit clinical bedside rounds: randomised trial and focus group discussion

    Science.gov (United States)

    Boswell, Danette; Broom, Margaret; Smith, Judith; Davis, Deborah

    2015-01-01

    Background There are limited data to inform the choice between parental presence at clinical bedside rounds (PPCBR) and non-PPCBR in neonatal intensive care units (NICUs). Methods We performed a single-centre, survey-based, crossed-over randomised trial involving parents of all infants who were admitted to NICU and anticipated to stay >11 days. Parents were randomly assigned using a computer-generated stratified block randomisation protocol to start with PPCBR or non-PPCBR and then crossed over to the other arm after a wash-out period. At the conclusion of each arm, parents completed the ‘NICU Parental Stressor Scale’ (a validated tool) and a satisfaction survey. After completion of the trial, we surveyed all healthcare providers who participated at least in one PPCBR rounding episode. We also offered all participating parents and healthcare providers the opportunity to partake in a focus group discussion regarding PPCBR. Results A total of 72 parents were enrolled in this study, with 63 parents (87%) partially or fully completing the trial. Of the parents who completed the trial, 95% agreed that parents should be allowed to attend clinical bedside rounds. A total of 39 healthcare providers’ surveys were returned and 35 (90%) agreed that parents should be allowed to attend rounds. Nine healthcare providers and 8 parents participated in an interview or focus group, augmenting our understanding of the ways in which PPCBR was beneficial. Conclusions Parents and healthcare providers strongly support PPCBR. NICUs should develop policies allowing PPCBR while mitigating the downsides and concerns of parents and healthcare providers such as decreased education opportunity and confidentiality concerns. Trial registration number Australia and New Zealand Clinical Trials Register number, ACTRN12612000506897. PMID:25711125

  18. An evaluation of the Parents Plus-Parenting When Separated programme.

    Science.gov (United States)

    Keating, Adele; Sharry, John; Murphy, Michelle; Rooney, Brendan; Carr, Alan

    2016-04-01

    This study evaluated the Parents Plus-Parenting when Separated Programme, an intervention specifically designed to address the needs of separated parents in an Irish context. In a randomized control trial, 82 separated parents with young children were assigned to the Parents Plus-Parenting when Separated Programme treatment group and 79 to a waiting-list control group. They were assessed on measures of client goals, parenting satisfaction, child and parental adjustment and interparental conflict at baseline (Time 1) and 6 weeks later (Time 2), after the treatment group completed the Parents Plus-Parenting when Separated Programme. From Time 1 to 2, significant goal attainment, increases in parenting satisfaction and decreases in child behaviour problems, parental adjustment problems and interparental conflict occurred in the Parents Plus-Parenting when Separated Programme group, but not in the control group. These results supported the effectiveness of Parents Plus-Parenting when Separated Programme, which should be made more widely available to separated parents. © The Author(s) 2015.

  19. Ultrasonographic Quantification of Fat Content in Fatty Liver Phantoms

    International Nuclear Information System (INIS)

    Kim, Il Young; Kim, Pyo Nyun; Joo, Gyung Soo; Kim, Ho Jung; Kim, Young Beom; Lee, Byoung Ho

    1995-01-01

    Assuming that the fat content of certain tissue might be quantified by measurirrg the ultrasound echo level, we analyzed the ultrasound histograms obtained from the fatty liver phantoms that contained various amount of fat. Various amount of margarine(Mazola. Cliff wood. USA) was mixed with 2% of agarin solution state to produce fatty liver phantoms that contained 5, 10, 20, 30 and 40% of fat. We obtained ultrasound histogram from each fatty liver phantom in gel state. We used 2% agar gel as a control. The ultrasound histograms from the control phantom showed gradual increase in echo level as the depth from the surface increased. The echo level from the phantom that contained 5% of fat showed gradual increase and subsequent decrease with the peak echo level at the depth of 3cm. The echo levels from the phantoms that contained more in 5% of fat gradually decreased as the depth from the surface increased; the change becoming more pronounced as the fat content of the phantom increased. The echo levels measured at the depth of 1cm were 9.3(control), 29.6(5%phantom), 3l.3 (10% phantom), 26.3 (20% phantom), l8.8 (30% phantom), and l6dB (40% phantom). Fat content of fatty phantoms can not be quantified by measuring only echo level. Simultaneous measurement of attenuation of ultrasound, which is not easy to do and not done in this study, is prerequisite to quantify fat content

  20. Phantom Eye Syndrome: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Agda M. Andreotti

    2014-01-01

    Full Text Available The purpose of this literature review was to describe the main features of phantom eye syndrome in relation to their possible causes, symptoms, treatments, and influence of eye amputation on quality of life of anophthalmic patients. For this, a bibliographical research was performed in Pubmed database using the following terms: “eye amputation,” “eye trauma,” “phantom eye syndrome,” “phantom pain,” and “quality of life,” associated or not. Thirteen studies were selected, besides some relevant references contained in the selected manuscripts and other studies hallowed in the literature. Thus, 56 articles were included in this review. The phantom eye syndrome is defined as any sensation reported by the patient with anophthalmia, originated anophthalmic cavity. In phantom eye syndrome, at least one of these three symptoms has to be present: phantom vision, phantom pain, and phantom sensations. This syndrome has a direct influence on the quality of life of the patients, and psychological support is recommended before and after the amputation of the eyeball as well as aid in the treatment of the syndrome. Therefore, it is suggested that, for more effective treatment of phantom eye syndrome, drug therapy should be associated with psychological approach.

  1. A phantom for quality control in mammography

    International Nuclear Information System (INIS)

    Gambaccini, M.; Rimondi, O.; Marziani, M.; Toti, A.

    1989-01-01

    A phantom for evaluating image quality in mammography has been designed and will be used in the Italian national programme ''Dose and Quality in Mammography''. The characteristics of the phantom are (a) about the same X-ray transmission as a 5 cm 50% fat and 50% water breast for energies between 15 and 50 keV and (b) optimum energies for imaging of the test objects (included in the phantom) in very close agreement with the optimum energies for imaging of calcifications and tumours in a 5 cm 50% fat and 50% water breast. An experimental comparison between the prototype and some commercial phantoms was carried out. Measurements are in progress to test the phantom's ability to evaluate the performances of mammographic systems quantitatively. (author)

  2. Notes to Parents - When Your Child Has Undergone Amputation.

    Science.gov (United States)

    Pierson, Margaret Hauser

    Designed to provide parents with basic information about the physical and emotional aspects of amputation, the booklet gives information about the grief response, body image, phantom limb sensation, stump care, and the prosthesis. The section on the grief process describes normal reactions to loss: denial, anger, bargaining, depression, and…

  3. Phantom cosmology without Big Rip singularity

    Energy Technology Data Exchange (ETDEWEB)

    Astashenok, Artyom V. [Baltic Federal University of I. Kant, Department of Theoretical Physics, 236041, 14, Nevsky st., Kaliningrad (Russian Federation); Nojiri, Shin' ichi, E-mail: nojiri@phys.nagoya-u.ac.jp [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Odintsov, Sergei D. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Institucio Catalana de Recerca i Estudis Avancats - ICREA and Institut de Ciencies de l' Espai (IEEC-CSIC), Campus UAB, Facultat de Ciencies, Torre C5-Par-2a pl, E-08193 Bellaterra (Barcelona) (Spain); Tomsk State Pedagogical University, Tomsk (Russian Federation); Yurov, Artyom V. [Baltic Federal University of I. Kant, Department of Theoretical Physics, 236041, 14, Nevsky st., Kaliningrad (Russian Federation)

    2012-03-23

    We construct phantom energy models with the equation of state parameter w which is less than -1, w<-1, but finite-time future singularity does not occur. Such models can be divided into two classes: (i) energy density increases with time ('phantom energy' without 'Big Rip' singularity) and (ii) energy density tends to constant value with time ('cosmological constant' with asymptotically de Sitter evolution). The disintegration of bound structure is confirmed in Little Rip cosmology. Surprisingly, we find that such disintegration (on example of Sun-Earth system) may occur even in asymptotically de Sitter phantom universe consistent with observational data. We also demonstrate that non-singular phantom models admit wormhole solutions as well as possibility of Big Trip via wormholes.

  4. Phantom cosmology without Big Rip singularity

    International Nuclear Information System (INIS)

    Astashenok, Artyom V.; Nojiri, Shin'ichi; Odintsov, Sergei D.; Yurov, Artyom V.

    2012-01-01

    We construct phantom energy models with the equation of state parameter w which is less than -1, w<-1, but finite-time future singularity does not occur. Such models can be divided into two classes: (i) energy density increases with time (“phantom energy” without “Big Rip” singularity) and (ii) energy density tends to constant value with time (“cosmological constant” with asymptotically de Sitter evolution). The disintegration of bound structure is confirmed in Little Rip cosmology. Surprisingly, we find that such disintegration (on example of Sun-Earth system) may occur even in asymptotically de Sitter phantom universe consistent with observational data. We also demonstrate that non-singular phantom models admit wormhole solutions as well as possibility of Big Trip via wormholes.

  5. Communal normalization in an online self-help group for adolescents with a mentally ill parent.

    Science.gov (United States)

    Trondsen, Marianne V; Tjora, Aksel

    2014-10-01

    Although implications of parental mental illness are well documented, most children of mentally ill parents are left to manage their family situation with limited information and support. We explored the role of a Norwegian online self-help group for adolescents (aged 15 to 18) with a mentally ill parent. Through in-depth interviews with 13 participants, we found that the online self-help group provided "communal normalization" by which participants, through communication in the forum, made sense of everyday experiences and emotions arising from having a mentally ill parent. We identified three main aspects of this process-recognizability, openness, and agency-all of which were important for the adolescents' efforts to obtain support, to be supportive, and to handle everyday life situations better. Communal normalization might provide resources for significantly improving the participants' life situations, and could demonstrate similar potential for users in other situations characterized by stigma, loneliness, silence, and health worries. © The Author(s) 2014.

  6. Development of digital phantom for DRR evaluation

    International Nuclear Information System (INIS)

    Ikeda, Tsuyoshi; Katsuta, Shoichi; Oyama, Masaya; Ogino, Takashi

    2009-01-01

    Generally, digitally reconstructed radiograph (DRR) is evaluated by physical phantom. The CT image is camouflaged by the performance of the radiation treatment planning system and contains a variety of error factors. The CT image (as follows the digital phantom), where an arbitrary CT value is arranged in the matrix, is necessary to evaluate the pure performance of the radiation treatment planning system. In this study, the development of a digital phantom is described, and the utility is discussed. CTport and the radiation treatment planning system are evaluated with the use of a digital phantom as follows: geometrical accuracy evaluation of DRR, consisting of the center position, size of irradiation field, distortion, extension of X-ray, and beam axis, and the image quality evaluation of DRR, which consists of the contrast resolution. As for DRR made with CTport and the treatment planning system, the part that shifted geometrically was confirmed. In the image quality evaluation, there was a remarkable difference. Because the making accuracy and the installation accuracy of the phantom do not influence the digital phantom, the geometrical accuracy of the DRR is reliable. Because the CT conditions and the phantom factor have no influence, the peculiar DRR image quality can be evaluated and used to evaluate the best image processing parameters. (author)

  7. Development of the Reference Korean Female Voxel Phantom

    International Nuclear Information System (INIS)

    Ham, Bo Kyoung; Cho, Kun Woo; Yeom, Yoen Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol

    2012-01-01

    The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.967 X 1.967 X X 2.0619 mm 3 and the voxel array size is 261 X 109 X 825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351 X 2.0351 X 2.0747 mm 3 for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

  8. Development of the Reference Korean Female Voxel Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Bo Kyoung; Cho, Kun Woo [University of Science and Technology, Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Yeom, Yoen Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol [Hanyang University, Seoul (Korea, Republic of)

    2012-03-15

    The objective of this study is for development of the reference Korean female phantom, HDRK-Woman. The phantom was constructed by adjusting a Korean woman voxel phantom to the Reference Korean data. The Korean woman phantom had been developed based on the high-resolution color slice images obtained from an adult Korean female cadaver. There were a total of 39 organs including the 27 organs specified in ICRP 103 for effective dose calculation. The voxel resolution of the phantom was 1.967 X 1.967 X X 2.0619 mm{sup 3} and the voxel array size is 261 X 109 X 825 in the x, y and z directions. Then, the voxel resolution was changed to 2.0351 X 2.0351 X 2.0747 mm{sup 3} for adjustment of the height and total bone mass of the phantom to the Reference Korean data. Finally, the internal organs and tissue were adjusted using in-house software program developed for 3D volume adjustment of the organs and tissue. The effective dose values of HDRK phantoms were calculated for broad parallel photon beams using MCNPX Monte Carlo code and compared with those of ICRP phantoms.

  9. Development of a physical 3D anthropomorphic breast phantom

    Energy Technology Data Exchange (ETDEWEB)

    Carton, Ann-Katherine; Bakic, Predrag; Ullberg, Christer; Derand, Helen; Maidment, Andrew D. A. [Department of Radiology, University of Pennsylvania, 1 Silverstein Building, 3400 Spruce Street, Philadelphia, Pennsylvania 19104-4206 (United States); XCounter AB, Svaerdvaegen 11, SE-182 33 Danderyd (Sweden); Department of Radiology, University of Pennsylvania, 1 Silverstein Building, 3400 Spruce Street, Philadelphia, Pennsylvania 19104-4206 (United States)

    2011-02-15

    Purpose: Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. Methods: The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the voxel phantom consisting of the glandular tissue, skin, and Cooper's ligaments is separated into sections. These sections are then fabricated by high-resolution rapid prototyping using a single material with 50% glandular equivalence. The remaining adipose compartments are then filled using an epoxy-based resin (EBR) with 100% adipose equivalence. The phantom sections are stacked to form the physical anthropomorphic phantom. Results: The authors fabricated a prototype phantom corresponding to a 450 ml breast with 45% dense tissue, deformed to a 5 cm compressed thickness. Both the rapid prototype (RP) and EBR phantom materials are radiographically uniform. The coefficient of variation (CoV) of the relative attenuation between RP and EBR phantom samples was <1% and the CoV of the signal intensity within RP and EBR phantom samples was <1.5% on average. Digital mammography and reconstructed digital breast tomosynthesis images of the authors' phantom were reviewed by two radiologists; they reported that the images are similar in appearance to clinical images, noting there are still artifacts from air bubbles in the EBR. Conclusions: The authors have developed a technique to produce 3D anthropomorphic breast phantoms with known ground truth, yielding highly realistic x-ray images. Such phantoms may serve both qualitative and quantitative performance assessments for 2D and 3D breast x-ray imaging systems.

  10. What Hispanic parents do to encourage and discourage 3-5 year old children to be active: a qualitative study using nominal group technique.

    Science.gov (United States)

    O'Connor, Teresia M; Cerin, Ester; Hughes, Sheryl O; Robles, Jessica; Thompson, Deborah; Baranowski, Tom; Lee, Rebecca E; Nicklas, Theresa; Shewchuk, Richard M

    2013-08-06

    Hispanic preschoolers are less active than their non-Hispanic peers. As part of a feasibility study to assess environmental and parenting influences on preschooler physical activity (PA) (Niños Activos), the aim of this study was to identify what parents do to encourage or discourage PA among Hispanic 3-5 year old children to inform the development of a new PA parenting practice instrument and future interventions to increase PA among Hispanic youth. Nominal Group Technique (NGT), a structured multi-step group procedure, was used to elicit and prioritize responses from 10 groups of Hispanic parents regarding what parents do to encourage (5 groups) or discourage (5 groups) preschool aged children to be active. Five groups consisted of parents with low education (less than high school) and 5 with high education (high school or greater) distributed between the two NGT questions. Ten NGT groups (n = 74, range 4-11/group) generated 20-46 and 42-69 responses/group for practices that encourage or discourage PA respectively. Eight to 18 responses/group were elected as the most likely to encourage or discourage PA. Parental engagement in child activities, modeling PA, and feeding the child well were identified as parenting practices that encourage child PA. Allowing TV and videogame use, psychological control, physical or emotional abuse, and lack of parental engagement emerged as parenting practices that discourage children from being active. There were few differences in the pattern of responses by education level. Parents identified ways they encourage and discourage 3-5 year-olds from PA, suggesting both are important targets for interventions. These will inform the development of a new PA parenting practice scale to be further evaluated. Further research should explore the role parents play in discouraging child PA, especially in using psychological control or submitting children to abuse, which were new findings in this study.

  11. Leaders' limitations and approaches to creating conditions for interaction and communication in parental groups: A qualitative study.

    Science.gov (United States)

    Frykedal, Karin Forslund; Rosander, Michael; Barimani, Mia; Berlin, Anita

    2018-01-01

    The aim of this study was to describe and understand parental group (PG) leaders' experiences of creating conditions for interaction and communication. The data consisted of 10 interviews with 14 leaders. The transcribed interviews were analysed using thematic analysis. The results showed that the leaders' ambition was to create a parent-centred learning environment by establishing conditions for interaction and communication between the parents in the PGs. However, the leaders' experience was that their professional competencies were insufficient and that they lacked pedagogical tools to create constructive group discussions. Nevertheless, they found other ways to facilitate interactive processes. Based on their experience in the PG, the leaders constructed informal socio-emotional roles for themselves (e.g. caring role and personal role) and let their more formal task roles (e.g. professional role, group leader and consulting role) recede into the background, so as to remove the imbalance of power between the leaders and the parents. They believed this would make the parents feel more confident and make it easier for them to start communicating and interacting. This personal approach places them in a vulnerable position in the PG, in which it is easy for them to feel offended by parents' criticism, questioning or silence.

  12. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry

    DEFF Research Database (Denmark)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-01-01

    for children demonstrated that they follow the same trend when correlated with age. The constructed hybrid computational phantom library opens up the prospect of comprehensive radiation dosimetry calculations and risk assessment for the paediatric population of different age groups and diverse anthropometric...

  13. Computational anthropomorphic phantoms for radiation protection dosimetry: evolution and prospects

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lee, Jaiki

    2006-01-01

    Computational anthropomorphic phantoms are computer models of human anatomy used in the calculation of radiation dose distribution in the human body upon exposure to a radiation source. Depending on the manner to represent human anatomy, they are categorized into two classes: stylized and tomographic phantoms. Stylized phantoms, which have mainly been developed at the Oak Ridge National Laboratory (ORNL), describe human anatomy by using simple mathematical equations of analytical geometry. Several improved stylized phantoms such as male and female adults, pediatric series, and enhanced organ models have been developed following the first hermaphrodite adult stylized phantom, Medical Internal Radiation Dose (MIRD)-5 phantom. Although stylized phantoms have significantly contributed to dosimetry calculation, they provide only approximations of the true anatomical features of the human body and the resulting organ dose distribution. An alternative class of computational phantom, the tomographic phantom, is based upon three-dimensional imaging techniques such as Magnetic Resonance (MR) imaging and Computed Tomography (CT). The tomographic phantoms represent the human anatomy with a large number of voxels that are assigned tissue type and organ identity. To date, a total of around 30 tomographic phantoms including male and female adults, pediatric phantoms, and even a pregnant female, have been developed and utilized for realistic radiation dosimetry calculation. They are based on MRI/CT images or sectional color photos from patients, volunteers or cadavers. Several investigators have compared tomographic phantoms with stylized phantoms, and demonstrated the superiority of tomographic phantoms in terms of realistic anatomy and dosimetry calculation. This paper summarizes the history and current status of both stylized and tomographic phantoms, including Korean computational phantoms. Advantages, limitations, and future prospects are also discussed

  14. WE-D-303-00: Computational Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, John [Duke University Medical Center, Durham, NC (United States); Brigham and Women’s Hospital and Dana-Farber Cancer Institute, Boston, MA (United States)

    2015-06-15

    Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

  15. WE-D-303-00: Computational Phantoms

    International Nuclear Information System (INIS)

    Lewis, John

    2015-01-01

    Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems

  16. The Activity Support Scale for Multiple Groups (ACTS-MG): Child-reported Physical Activity Parenting in African American and Non-Hispanic White Families.

    Science.gov (United States)

    Lampard, Amy M; Nishi, Akihiro; Baskin, Monica L; Carson, Tiffany L; Davison, Kirsten K

    2016-01-01

    This study aimed to assess the psychometric properties of a child-report, multidimensional measure of physical activity (PA) parenting, the Activity Support Scale for Multiple Groups (ACTS-MG), in African American and non-Hispanic white families. The ACTS-MG was administered to children aged 5 to 12 years. A three factor model of PA parenting (Modeling of PA, Logistic Support, and Restricting Access to Screen-based Activities) was tested separately for mother's and fathers' PA parenting. The proposed three-factor structure was supported in both racial groups for mothers' PA parenting and in the African American sample for fathers' PA parenting. Factorial invariance between racial groups was demonstrated for mother's PA parenting. Building on a previous study examining the ACTS-MG parent-report, this study supports the use of the ACTS-MG child-report for mothers' PA parenting. However, further research is required to investigate the measurement of fathers' PA parenting across racial groups.

  17. Group-based parent training programmes for improving emotional and behavioural adjustment in young children.

    Science.gov (United States)

    Barlow, Jane; Bergman, Hanna; Kornør, Hege; Wei, Yinghui; Bennett, Cathy

    2016-08-01

    Emotional and behavioural problems in children are common. Research suggests that parenting has an important role to play in helping children to become well-adjusted, and that the first few months and years are especially important. Parenting programmes may have a role to play in improving the emotional and behavioural adjustment of infants and toddlers, and this review examined their effectiveness with parents and carers of young children. 1. To establish whether group-based parenting programmes are effective in improving the emotional and behavioural adjustment of young children (maximum mean age of three years and 11 months); and2. To assess whether parenting programmes are effective in the primary prevention of emotional and behavioural problems. In July 2015 we searched CENTRAL (the Cochrane Library), Ovid MEDLINE, Embase (Ovid), and 10 other databases. We also searched two trial registers and handsearched reference lists of included studies and relevant systematic reviews. Two reviewers independently assessed the records retrieved by the search. We included randomised controlled trials (RCTs) and quasi-RCTs of group-based parenting programmes that had used at least one standardised instrument to measure emotional and behavioural adjustment in children. One reviewer extracted data and a second reviewer checked the extracted data. We presented the results for each outcome in each study as standardised mean differences (SMDs) with 95% confidence intervals (CIs). Where appropriate, we combined the results in a meta-analysis using a random-effects model. We used the GRADE (Grades of Recommendations, Assessment, Development, and Evaluation) approach to assess the overall quality of the body of evidence for each outcome. We identified 22 RCTs and two quasi-RCTs evaluating the effectiveness of group-based parenting programmes in improving the emotional and behavioural adjustment of children aged up to three years and 11 months (maximum mean age three years 11 months

  18. Reported parental characteristics in relation to trait depression and anxiety levels in a non-clinical group.

    Science.gov (United States)

    Parker, G

    1979-09-01

    Care and overprotection appear to reflect the principal dimensions underlying parental behaviours and attitudes. In previous studies of neurotically depressed patients and of a non-clinical group, subjects who scored their parents as lacking in care and/or overprotective had the greater depressive experience. The present study of another non-clinical group (289 psychology students) replicated those findings in regard to trait depression levels. In addition, associations between those parental dimensions and trait anxiety scores were demonstrated. Multiple regression analyses established that 9-10% of the variance in mood scores was accounted for by scores on those parental dimensions. Low maternal care scores predicted higher levels of both anxiety and depression, while high maternal overprotection scores predicted higher levels of anxiety but not levels of depression. Maternal influences were clearly of greater relevance than paternal influences.

  19. Lost in translation: a focus group study of parents’ and adolescents’ interpretations of underage drinking and parental supply

    Directory of Open Access Journals (Sweden)

    Sandra C. Jones

    2016-07-01

    Full Text Available Abstract Background Reductions in underage drinking will only come about from changes in the social and cultural environment. Despite decades of messages discouraging parental supply, parents perceive social norms supportive of allowing children to consume alcohol in ‘safe’ environments. Methods Twelve focus groups conducted in a regional community in NSW, Australia; four with parents of teenagers (n = 27; 70 % female and eight with adolescents (n = 47; 55 % female. Participants were recruited using local media. Groups explored knowledge and attitudes and around alcohol consumption by, and parental supply of alcohol to, underage teenagers; and discussed materials from previous campaigns targeting adolescents and parents. Results Parents and adolescents perceived teen drinking to be a common behaviour within the community, but applied moral judgements to these behaviours. Younger adolescents expressed more negative views of teen drinkers and parents who supply alcohol than older adolescents. Adolescents and parents perceived those who ‘provide alcohol’ (other families as bad parents, and those who ‘teach responsible drinking’ (themselves as good people. Both groups expressed a preference for high-fear, victim-blaming messages that targeted ‘those people’ whose behaviours are problematic. Conclusions In developing and testing interventions to address underage drinking, it is essential to ensure the target audience perceive themselves to be the target audience. If we do not have a shared understanding of underage ‘drinking’ and parental ‘provision’, such messages will continue to be perceived by parents who are trying to do the ‘right’ thing as targeting a different behaviour and tacitly supporting their decision to provide their children with alcohol.

  20. [Mirror, mirror of the wall: mirror therapy in the treatment of phantom limbs and phantom limb pain].

    Science.gov (United States)

    Casale, Roberto; Furnari, Anna; Lamberti, Raul Coelho; Kouloulas, Efthimios; Hagenberg, Annegret; Mallik, Maryam

    2015-01-01

    Phantom limb and phantom limb pain control are pivotal points in the sequence of intervention to bring the amputee to functional autonomy. The alterations of perception and sensation, the pain of the residual limb and the phantom limb are therefore aspects of amputation that should be taken into account in the "prise en charge" of these patients. Within the more advanced physical therapies to control phantom and phantom limb pain there is the use of mirrors (mirror therapy). This article willfocus on its use and on the possible side effects induced by the lack of patient selection and a conflict of body schema restoration through mirror therapy with concurrent prosthetic training and trauma acceptance. Advice on the need to select patients before treatment decisions, with regard to their psychological as well as clinical profile (including time since amputation and clinical setting), and the need to be aware of the possible adverse effects matching different and somehow conflicting therapeutic approaches, are put forward. Thus a coordinated sequence of diagnostic, prognostic and therapeutic procedures carried out by an interdisciplinary rehabilitation team that works globally on all patients' problems is fundamental in the management of amputees and phantom limb pain. Further studies and the development of a multidisciplinary network to study this and other applications of mirror therapy are needed.

  1. Contrast detail phantom for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejas, M.L. de; Arashiro, J G; Giannone, C. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Camuyrano, M; Nohara, G [Universidad de Buenos Aires, Buenos Aires (Argentina). Facultad Ciencias Exactas

    1996-06-01

    A new low variable contrast phantom for single photon emission computed tomography (SPECT) was constructed, tested and compared with other existing phantoms. It contains simulated cylindrical lesions of four different diameters (D{sub i}), embedded in a cylindrical scattering medium and a uniform section to evaluate tomographic uniformity. The concentration of tracer in the simulated lesions and the scattering medium (background) can be varied to simulate hot and cold lesions. Different applications of the phantom were tested, including determination of the minimum object contrast (OCm) necessary to detect lesions as a function of lesion size, lesion type (hot or cold) and acquisition and processing protocols by visual inspection. This parameter allows categorization of instruments comparing an `image quality index` (IQI). Preliminary comparison with the Britten contrast processing method showed that the detectable OCm was of the same order of magnitude, but the presented device seems more suitable for training and intercomparison purposes. The constructed phantom, of simple design, has proved to be useful for acquisition and processing condition evaluation, OCm estimation and external quality control. (author). 11 refs, 4 figs.

  2. Longitudinal Associations between Parenting and Youth Adjustment in Twelve Cultural Groups: Cultural Normativeness of Parenting as a Moderator

    Science.gov (United States)

    Lansford, Jennifer E.; Godwin, Jennifer; Al-Hassan, Suha M.; Bacchini, Dario; Bornstein, Marc H.; Chang, Lei; Chen, Bin-Bin; Deater-Deckard, Kirby; Di Giunta, Laura; Dodge, Kenneth A.; Malone, Patrick S.; Oburu, Paul; Pastorelli, Concetta; Skinner, Ann T.; Sorbring, Emma; Steinberg, Laurence; Tapanya, Sombat; Alampay, Liane Peña; Uribe Tirado, Liliana Maria; Zelli, Arnaldo

    2018-01-01

    To examine whether the cultural normativeness of parents' beliefs and behaviors moderates the links between those beliefs and behaviors and youths' adjustment, mothers, fathers, and children (N = 1,298 families) from 12 cultural groups in 9 countries (China, Colombia, Italy, Jordan, Kenya, Philippines, Sweden, Thailand, and the United States) were…

  3. Mathematical human phantoms and their application to radiation protection

    International Nuclear Information System (INIS)

    Yamaguchi, Yasuhiro

    1998-01-01

    This review described the characteristics of mathematical phantoms, their history over 30 years and their application. Mathematical phantoms are classified into two models of formula and voxel types. In the former, human body and organs are described by 2- and/or 3-D mathematical formula and can be seen as a combination of solid bodies like spheres, cubes and ovals. The phantom is composed from three tissue components (bone, lung and soft tissue) and made on data on Reference Man in ICRP Publ. 23. The latter voxel (volume pixel) phantom consists from a number of small cubes based on CT and MRI images of a certain man. For instance, the phantom CHILD, 1.54 x 1.54 x 8.00 mm 3 in size, is based on a 7-year old child, which consisting from about one million voxels. The mathematical phantom was first made in Oak Ridge National Laboratory in the middle of the nineteen-sixties, which have undergone various improvements to reach MIRD-5 phantom. Thereafter, many similitude phantoms have been made as a variation of MIRD-5, depending on age and sex (e.g., ADAM and EVA). Voxel phantom was made in the middle of nineteen-eighties and have undergone improvements which are continued even currently in Japan, U.S. etc. The mathematical phantoms are used for calculation of radiation transport program by Monte Carlo method in the field of radiation protection. Also in the field of medicine, the phantom is used for calculation of internal and external exposure doses, of correction constants of externally measuring instruments, of doses for neutron capture therapy and of A-bomb exposure doses in Hiroshima and Nagasaki for reevaluation. Recently, the development of phantom is in the current from formula phantom to voxel one due to the purpose of precision and standardization. (K.H.)

  4. A dynamic phantom for radionuclide renography

    International Nuclear Information System (INIS)

    Heikkinen, J.O.

    1999-01-01

    The aim of the study was to develop and test a dynamic phantom simulating radionuclide renography. The phantom consisted of five partly lead covered plastic containers simulating kidneys, heart, bladder and background (soft tissues, liver and spleen). Dynamics were performed with multiple movable steel plates between containers and a gamma camera. Control of the plates is performed manually with a stopwatch following exact time schedules. The containers were filled with activities ( 99m Tc) which produce count rates close to clinical situations. Count rates produced by the phantom were compared with ten clinical renography cases: five 99m Tc MAG3 and five 99m Tc DTPA examinations. Two phantom simulations were repeated three times with separate fillings, acquisitions and analyses. Precision errors as a coefficient of variation (CV) of repeated measurements were calculated and theoretical values were compared with the corresponding measured ones. A multicentre comparison was made between 19 nuclear medicine laboratories and three clinical cases were simulated with the phantom. Correlations between count rates produced by the phantom and clinical studies were r=0.964 for 99m Tc MAG3 (p 99m Tc DTPA (p max was 4.0±1.6%. Images and curves of the scanned phantom were close to a real patient in all 19 laboratories but calculated parameters varied: the difference between theoretical and measured values for T max was 6.8±6.2%. The difference between laboratories is most probably due to variations in acquisition protocols and analysis programs: 19 laboratories with 18 different protocols and 8 different programs. The dynamics were found to be repeatable and suitable for calibration purposes for radionuclide renography programs and protocols as well as for multicentre comparisons. (author)

  5. Children’s experiences and meaning construction on parental divorce: A focus group study

    OpenAIRE

    Maes, Sofie DJ; De Mol, Jan; Buysse, Ann

    2011-01-01

    The global aim of this study was to explore children's narratives of parental divorce. A convenience sample, composed of 11- and 14-year-old children, was recruited. A total of 22 children (12 male, 10 female) participated in this focus group study. The findings show that two components seem to be really important for children during the divorce process: the ability to construct meaning about their parents' decision to divorce and their feeling to count in the process of family transition. Ch...

  6. Phantom inflation and the 'Big Trip'

    International Nuclear Information System (INIS)

    Gonzalez-Diaz, Pedro F.; Jimenez-Madrid, Jose A.

    2004-01-01

    Primordial inflation is regarded to be driven by a phantom field which is here implemented as a scalar field satisfying an equation of state p=ωρ, with ω-1. Being even aggravated by the weird properties of phantom energy, this will pose a serious problem with the exit from the inflationary phase. We argue, however, in favor of the speculation that a smooth exit from the phantom inflationary phase can still be tentatively recovered by considering a multiverse scenario where the primordial phantom universe would travel in time toward a future universe filled with usual radiation, before reaching the big rip. We call this transition the 'Big Trip' and assume it to take place with the help of some form of anthropic principle which chooses our current universe as being the final destination of the time transition

  7. Parental care in a polygynous group of bat-eared foxes, Otocyon ...

    African Journals Online (AJOL)

    This study reports the first recorded instance of polygyny and communal nursing in Otocyon m. megalotis. The polygynous group, which was studied in the Kalahari Desert, consisted of a male, two lactating females and a litter of five pups. New aspects of parental care that were observed include the bringing of food items to ...

  8. Charged black holes in phantom cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, Mubasher; Qadir, Asghar; Rashid, Muneer Ahmad [National University of Sciences and Technology, Center for Advanced Mathematics and Physics, Rawalpindi (Pakistan)

    2008-11-15

    In the classical relativistic regime, the accretion of phantom-like dark energy onto a stationary black hole reduces the mass of the black hole. We have investigated the accretion of phantom energy onto a stationary charged black hole and have determined the condition under which this accretion is possible. This condition restricts the mass-to-charge ratio in a narrow range. This condition also challenges the validity of the cosmic-censorship conjecture since a naked singularity is eventually produced due to accretion of phantom energy onto black hole. (orig.)

  9. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  10. Effectiveness of preventive support groups for children of mentally ill or addicted parents: a randomized controlled trial.

    Science.gov (United States)

    van Santvoort, Floor; Hosman, Clemens M H; van Doesum, Karin T M; Janssens, Jan M A M

    2014-06-01

    In various countries preventive support groups are offered to children of mentally ill and/or addicted parents to reduce the risk that they will develop problems themselves. This study assessed the effectiveness of Dutch support groups for children aged 8-12 years old in terms of reducing negative cognitions; improving social support, competence, and parent-child interaction (direct intervention goals); and reducing emotional and behavioural problems (ultimate intervention aim). Children from 254 families were randomly assigned to the intervention or a control condition. Parents and children completed questionnaires at baseline and 3 and 6 months later. Emotional and behavioural problems of intervention group children were also assessed 1 year after the start. Univariate analyses of variance showed that children in the intervention group experienced a greater decrease in negative cognitions and sought more social support, immediately after participation and 3 months later, as compared to control group children. They also remained stable in their feelings of social acceptance (competence aspect) immediately after the intervention, whereas these feelings declined in control group children. The intervention and control groups both improved over time in terms of cognitions, competence, parent-child interaction and emotional and behavioural problem scores. Additional improvement in terms of problem scores was found in the intervention group 1 year after baseline. Further enhancement of effectiveness requires re-consideration of the support group goals; it should be studied whether the goals reflect the most important and influential risk and protective factors for this specific population. Besides, effects should be studied over a longer period.

  11. What is good parental education? Interviews with parents who have attended parental education sessions.

    Science.gov (United States)

    Petersson, Kerstin; Petersson, Christer; Håkansson, Anders

    2004-03-01

    The aim of the study was to highlight the experiences and expectations of Swedish parents with respect to general parental education within child healthcare. Interviews were carried out with 25 parents who had attended education sessions. With a few exceptions the fathers did not take part, and those mothers who did comprised a relatively highly educated group; their views therefore predominate in this study. Socially vulnerable parents such as the unemployed and immigrants took part more sporadically in the meetings, which is why less material is available from these groups. The arrangement and analysis of the material was done using qualitative content analysis. We identified two main categories of importance: 'parental education content' and 'parental education structure'. The parents were on the whole satisfied with the content with respect to the child's physical and psychosocial development. On the other hand, first-time parents expressed a degree of uncertainty with respect to the new parent roles and parent relation and they thought that the education should place more emphasis on the interplay between the parents and between child and parents. The degree of confidence in the nurse as group leader was mainly high. The parents thought that the groups functioned well socially and were satisfied with the organization of the meetings. They did, however, demand clearer structure and framework with respect to the content. Since the aim of legally established parental education is to improve the conditions of childhood growth and to provide support to parents, it must be considered especially important to provide resources so that the socially vulnerable groups in the community may also be reached.

  12. Experimental phantom verification studies for simulations of light interactions with skin: liquid phantoms

    CSIR Research Space (South Africa)

    Karsten, A

    2010-09-01

    Full Text Available stream_source_info Karsten_2010_P.pdf.txt stream_content_type text/plain stream_size 5080 Content-Encoding UTF-8 stream_name Karsten_2010_P.pdf.txt Content-Type text/plain; charset=UTF-8 Experimental phantom verification... studies for simulations of light interactions with skin: Solid Phantoms Aletta E Karsten, A Singh Presented by: J E Smit National Laser Center CSIR South Africa akarsten@csir.co.za Slide 2 © CSIR 2009 www.csir.co.za Where...

  13. The influence of parenting on maladaptive cognitive schema: a cross-sectional research on a group of adults.

    Science.gov (United States)

    Pellerone, Monica; Iacolino, Calogero; Mannino, Giuseppe; Formica, Ivan; Zabbara, Simona Maria

    2017-01-01

    The literature emphasizes the role of early interpersonal experiences in the development of cognitive vulnerability; in particular, interruptions in early family relationships, parental unavailability and dysfunctional parenting are potential evolutionary precursors to negative cognitive style and emotional disorders. This study measured the relationship of retrospective ratings on parental bonding with cognitive patterns in a group of Italian adults. The objectives of this study were as follows: to analyze the influence of age and education level on cognitive domains; to verify whether being parents and living at home with parents affect both parenting style and cognitive domains; to investigate how the type of the maternal and paternal parenting independently affects cognitive styles; to measure the predictive variables for the use of cognitive dysfunctional patterns and to investigate age as a moderating variable of the relation between parenting styles and cognitive domains in a group of adult men and women. The research involved 209 adults (118 males and 91 females) living in Sicily (Italy) aged between 20 and 60 years ( M = 37.52; SD = 11.42). The research lasted for 1 year. The instruments used were the Parental Bonding Instrument to measure the perception of parenting during childhood and the Young Schema Questionnaire-3 to investigate cognitive patterns. Data show that being a younger adult male with mother's parenting style characterized by a lower level of nurturance is predictive of the disconnection and rejection domain, whereas, being a younger adult woman, with a higher level of maternal control is predictive of the impaired limits domain. This study underlines that because mothers and fathers establish different bonds with their children, care and control by both parents might impact different domains of development.

  14. Simulation of a Quality Control Jaszczak Phantom with SIMIND Monte Carlo and Adding the Phantom as an Accessory to the Program

    International Nuclear Information System (INIS)

    Pirayesh Islamian, J.; Bahreyni Toosi, M. T.; Momennezhad, M.; Naseri, Sh.; Ljungberg, M.

    2012-01-01

    Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established for SPECT. The simulation was based on a Deluxe model of Jaszczak Phantom with defined geometry. Quality control tests were provided together with initial imaging example and suggested use for the assessment of parameters such as spatial resolution, limits of lesion detection, and contrast comparing with a Siemens E.Cam SPECT system. The phantom simulation was verified by matching tomographic spatial resolution, image contrast, and also uniformity compared with the experiment SPECT of the phantom from filtered backprojection reconstructed images of the spheres and rods. The calculated contrasts of the rods were 0.774, 0.627, 0.575, 0.372, 0.191, and 0.132 for an experiment with the rods diameters of 31.8, 25.4, 19.1, 15.9, 12.7, and 9.5 mm, respectively. The calculated contrasts of simulated rods were 0.661, 0.527, 0.487, 0.400, 0.23, and 0.2 for cold rods and also 0.92, 0.91, 0.88, 0.81, 0.76, and 0.56 for hot rods. Reconstructed spatial tomographic resolution of both experiment and simulated SPECTs of the phantom obtained about 9.5 mm. An executable phantom file and an input phantom file were created for the SIMIND Monte Carlo program. This phantom may be used for simulated SPECT systems and would be ideal for verification of the simulated systems with real ones by comparing the results of quality control and image evaluation. It is also envisaged that this phantom could be used with a range of radionuclide doses in simulation situations such as cold, hot, and background uptakes for the assessment of detection characteristics when a new similar clinical SPECT procedure is being simulated.

  15. Simulation of a Quality Control Jaszczak Phantom with SIMIND Monte Carlo and Adding the Phantom as an Accessory to the Program

    Directory of Open Access Journals (Sweden)

    Jalil Pirayesh Islamian

    2012-03-01

    Full Text Available Introduction Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established for SPECT. Materials and Methods The simulation was based on a Deluxe model of Jaszczak Phantom with defined geometry. Quality control tests were provided together with initial imaging example and suggested use for the assessment of parameters such as spatial resolution, limits of lesion detection, and contrast comparing with a Siemens E.Cam SPECT system. Results The phantom simulation was verified by matching tomographic spatial resolution, image contrast, and also uniformity compared with the experiment SPECT of the phantom from filtered backprojection reconstructed images of the spheres and rods. The calculated contrasts of the rods were 0.774, 0.627, 0.575, 0.372, 0.191, and 0.132 for an experiment with the rods diameters of 31.8, 25.4, 19.1, 15.9, 12.7, and 9.5 mm, respectively. The calculated contrasts of simulated rods were 0.661, 0.527, 0.487, 0.400, 0.23, and 0.2 for cold rods and also 0.92, 0.91, 0.88, 0.81, 0.76, and 0.56 for hot rods. Reconstructed spatial tomographic resolution of both experiment and simulated SPECTs of the phantom obtained about 9.5 mm. An executable phantom file and an input phantom file were created for the SIMIND Monte Carlo program. Conclusion This phantom may be used for simulated SPECT systems and would be ideal for verification of the simulated systems with real ones by comparing the results of quality control and image evaluation. It is also envisaged that this phantom could be used with a range of radionuclide doses in simulation situations such as cold, hot, and background uptakes for the assessment of detection

  16. Puzzles of dark energy in the Universe—phantom

    International Nuclear Information System (INIS)

    Dabrowski, Mariusz P

    2015-01-01

    This paper is devoted to some simple approach based on general physics tools to describe the physical properties of a hypothetical particle which can be the source of dark energy in the Universe known as phantom. Phantom is characterized by the fact that it possesses negative momentum and kinetic energy and that it gives dominant negative pressure which acts as antigravity. We consider a phantom harmonic oscillator in comparison to a standard harmonic oscillator. By using the first law of thermodynamics we explain why the energy density of the Universe grows when it is filled with phantom. We also show how the collision of phantom with a standard particle leads to extraction of energy from the former by the latter (i.e. from phantom to the standard) if their masses are different. The most striking of our conclusions is that the collision of phantom and standard particles of the same mass is impossible unless both of them are at rest and suddenly start moving with opposite velocities and kinetic energies. This effect is a classic analog of quantum mechanical particle pair creation in a strong electric field or physical vacuum. (paper)

  17. Mathematical phantom of Indian adult for radiation dosimetry

    International Nuclear Information System (INIS)

    Jain, S.C.; Tyagi, K.

    2000-01-01

    Various countries have either developed or are in process of developing their own reference man for radiation protection purposes. Efforts are made to develop Indian Reference Man, especially by scientific groups at DRDO and BARC. The proposed mathematical phantom of Indian adult will be useful for estimation of radiation dose to various organs from radiation sources from external as well as internal, and compute the effective dose

  18. The support needs of parents having a child with a chronic kidney disease: a focus group study.

    Science.gov (United States)

    Geense, W W; van Gaal, B G I; Knoll, J L; Cornelissen, E A M; van Achterberg, T

    2017-11-01

    Parents of children with a chronic kidney disease (CKD) have a crucial role in the management of their child's disease. The burden on parents is high: they are often exhausted, depressed and experience high levels of stress and a low quality of life, which could have a negative impact on their child's health outcomes. Support aiming at preventing and reducing parental stress is essential. Therefore, it is necessary to have insight in the problems and support needs among these parents. Our aim is to describe parents' support needs regarding the problems they experience in having a child with CKD. Five focus group interviews were conducted with parents of children: (i) with hereditary kidney disease, (ii) with nephrotic syndrome, (iii) with chronic kidney failure, (iv) using dialysis and (v) after renal transplantation. The children were treated at a paediatric nephrology unit in one university hospital in the Netherlands. The data were thematically analysed. Twenty-one parents participated in the focus groups. Parents need more information about their child's CKD and treatment options, and managing their own hobbies and work. Furthermore, parents need emotional support from their partner, family, friends, peers and healthcare professionals to help them cope with the disease of their child. Additionally, parents need practical support to hand over their care and support in transport, financial management and regarding their child at school. Needs regarding balancing their personal life are seldom prioritized by parents as the child's needs are considered more important. Therefore, it is important that healthcare professionals should not only attend to the abilities of parents concerning their child's disease management, but also focus on the parents' abilities in balancing their responsibilities as a caregiver with their own personal life. © 2017 John Wiley & Sons Ltd.

  19. ICRU activity in the field of phantoms in diagnostic radiology

    International Nuclear Information System (INIS)

    Wambersie, A.

    1992-01-01

    The ICRU Report on 'Phantoms and Computational Models in Radiation Therapy, Diagnosis and Protection' is presented. Different types of phantoms may be defined. They may be broadly categorized according to their primary function: dosimetry, calibration and imaging. Within each functional category, there are 3 types or designs of phantoms: body phantoms (anthropomorphic), standard phantoms and reference phantoms (used in the definition and specification of certain radiation quantities). In radiological imaging, anthropomorphic body phantoms are used for measuring the absorbed dose distribution resulting from imaging procedures. Standard phantoms have simple reproducible geometry and are used for comparing measurements under standard conditions of exposure. Imaging phantoms are useful for evaluating a given imaging system; they contain different types of test pieces. The report contains a major section on human anatomy, from fetus to adult with the variations due to ethnic origin. Tolerance levels for the phantoms (composition, dimensions) are proposed and quality assurance programs are outlined. The report contains extensive appendices; human anatomical data and full specification of over 80 phantoms and computational models. ICRU Report 46 on 'Photon, electron, proton and neutron interaction data for body tissues' is closely related to the field of phantoms. It is a logical continuation on ICRU Report 44 (1989) on 'Tissue substitutes in radiation dosimetry and measurements' and contains the interaction data for more than 100 tissues, from fetal to adult, including some diseased tissues

  20. Vaccination decision-making of immigrant parents in the Netherlands; a focus group study.

    Science.gov (United States)

    Harmsen, Irene A; Bos, Helien; Ruiter, Robert A C; Paulussen, Theo G W; Kok, Gerjo; de Melker, Hester E; Mollema, Liesbeth

    2015-12-10

    Although the vaccination coverage in most high income countries is high, variations in coverage rates on the national level among different ethnic backgrounds are reported. A qualitative study was performed to explore factors that influence decision-making among parents with different ethnic backgrounds in the Netherlands. Six focus groups were conducted with 33 mothers of Moroccan, Turkish and other ethnic backgrounds with at least one child aged 0-4 years. Data were analysed using thematic analysis. Parents had a positive attitude towards childhood vaccination and a high confidence in the advices of Child Vaccine Providers (CVPs). Vaccinating their children was perceived as self-evident and important. Parents do perceive a language barrier in understanding the provided NIP-information, and they had a need for more NIP- information, particularly about the targeted diseases. Another barrier parents perceived was the distance to the Child Welfare Center (CWC), especially when the weather was bad and when they had no access to a car. More information about targeted diseases and complete information regarding benefits and drawbacks of the NIP should be provided to the parents. To fulfill parents' information needs, NIP information meetings can be organized at CWCs in different languages. Providing NIP information material in Turkish, Arabic and Berber language with easy access is also recommended. Providing information tailored to these parents' needs is important to sustain high vaccination participation, and to ensure acceptance of future vaccinations.

  1. Patient specific 3D printed phantom for IMRT quality assurance

    International Nuclear Information System (INIS)

    Ehler, Eric D; Higgins, Patrick D; Dusenbery, Kathryn E; Barney, Brett M

    2014-01-01

    The purpose of this study was to test the feasibility of a patient specific phantom for patient specific dosimetric verification. Using the head and neck region of an anthropomorphic phantom as a substitute for an actual patient, a soft-tissue equivalent model was constructed with the use of a 3D printer. Calculated and measured dose in the anthropomorphic phantom and the 3D printed phantom was compared for a parallel-opposed head and neck field geometry to establish tissue equivalence. A nine-field IMRT plan was constructed and dose verification measurements were performed for the 3D printed phantom as well as traditional standard phantoms. The maximum difference in calculated dose was 1.8% for the parallel-opposed configuration. Passing rates of various dosimetric parameters were compared for the IMRT plan measurements; the 3D printed phantom results showed greater disagreement at superficial depths than other methods. A custom phantom was created using a 3D printer. It was determined that the use of patient specific phantoms to perform dosimetric verification and estimate the dose in the patient is feasible. In addition, end-to-end testing on a per-patient basis was possible with the 3D printed phantom. Further refinement of the phantom construction process is needed for routine use. (paper)

  2. Influence of Manufacturing Processes on the Performance of Phantom Lungs

    International Nuclear Information System (INIS)

    Traub, Richard J.

    2008-01-01

    Chest counting is an important tool for estimating the radiation dose to individuals who have inhaled radioactive materials. Chest counting systems are calibrated by counting the activity in the lungs of phantoms where the activity in the phantom lungs is known. In the United States a commonly used calibration phantom was developed at the Lawrence Livermore National Laboratory and is referred to as the Livermore Torso Phantom. An important feature of this phantom is that the phantom lungs can be interchanged so that the counting system can be challenged by different combinations of radionuclides and activity. Phantom lungs are made from lung tissue substitutes whose constituents are foaming plastics and various adjuvants selected to make the lung tissue substitute similar to normal healthy lung tissue. Some of the properties of phantom lungs cannot be readily controlled by phantom lung manufacturers. Some, such as density, are a complex function of the manufacturing process, while others, such as elemental composition of the bulk plastic are controlled by the plastics manufacturer without input, or knowledge of the phantom manufacturer. Despite the fact that some of these items cannot be controlled, they can be measured and accounted for. This report describes how manufacturing processes can influence the performance of phantom lungs. It is proposed that a metric that describes the brightness of the lung be employed by the phantom lung manufacturer to determine how well the phantom lung approximates the characteristics of a human lung. For many purposes, the linear attenuation of the lung tissue substitute is an appropriate surrogate for the brightness

  3. Ethnic Group Differences in Early Head Start Parents Parenting Beliefs and Practices and Links to Children's Early Cognitive Development

    Science.gov (United States)

    Keels, Micere

    2009-01-01

    Data from the Early Head Start Research and Evaluation study were used to examine the extent to which several factors mediate between- and within-ethnic-group differences in parenting beliefs and behaviors, and children's early cognitive development (analysis sample of 1198 families). The findings indicate that Hispanic-, European-, and…

  4. Design and development of a phantom for tomosynthesis with potential for automated analysis via the cloud.

    Science.gov (United States)

    Goodenough, David; Levy, Josh; Olafsdottir, Hildur; Olafsson, Ingvi

    2018-03-06

    This paper describes Development of a Phantom for Tomosynthesis with Potential for Automated Analysis via the Cloud. Several studies are underway to investigate the effectiveness of Tomosynthesis Mammographic Image Screening, including the large TMIST project as funded by the National Cancer Institute https://www.cancer.gov/about-cancer/treatment/clinical-trials/nci-supported/tmist. The development of the phantom described in this paper follows initiatives from the FDA, the AAPM TG245 task group, and European Reference Organization (EUREF) for Quality Assured Breast Screening and Diagnostic Services Committee report noting, that no formal endorsement nor recommendation for use has been sought, or granted by any of these groups. This paper reports on the possibility of using this newly developed Tomosynthesis Phantom for Quality Assurance, field testing of image performance, including remote monitoring of DBT system performance, e.g., via transmission over the cloud. The phantom includes tests for: phantom positioning and alignment (important for remote analysis), scan geometry (x and y), chest wall offset, scan slice width and Slice Sensitivity Profile (SSP(z)) slice geometry (slice width), scan slice incrementation (z), z axis geometry bead, low contrast detectability using low contrast spheres, spatial resolution via Point Spread Function (PSF), Image uniformity, Signal to Noise Ratio (SNR), and Contrast to Noise Ratio (CNR) via readings over an Aluminum square. The phantom is designed for use with automated analysis via transmission of images over the cloud and the analysis package includes test of positioning accuracy (roll, pitch, and yaw). Data are shown from several commercial Tomosynthesis Scanners including Fuji, GE, Hologic, IMS-Giotti, and Siemens; however, the focus of this paper is on phantom design, and not in general aimed at direct commercial comparisons, and wherever possible the identity of the data is anonymized. Results of automated analysis of

  5. The effectiveness of a short-term group music therapy intervention for parents who have a child with a disability.

    Science.gov (United States)

    Williams, Kate E; Berthelsen, Donna; Nicholson, Jan M; Walker, Sue; Abad, Vicky

    2012-01-01

    The positive relationship between parent-child interactions and optimal child development is well established. Families of children with disabilities may face unique challenges in establishing positive parent-child relationships; yet, there are few studies examining the effectiveness of music therapy interventions to address these issues. In particular, these studies have been limited by small sample size and the use of measures of limited reliability and validity. This study examined the effectiveness of a short-term group music therapy intervention for parents of children with disabilities and explored factors associated with better outcomes for participating families. Participants were 201 mother-child dyads, where the child had a disability. Pre- and post-intervention parental questionnaires and clinician observation measures were completed to examine outcomes of parental wellbeing, parenting behaviors, and child development. Descriptive data, t-tests for repeated measures and a predictive model tested via logistic regression are presented. Significant improvements pre to post intervention were found for parent mental health, child communication and social skills, parenting sensitivity, parental engagement with child and acceptance of child, child responsiveness to parent, and child interest and participation in program activities. There was also evidence for high parental satisfaction and that the program brought social benefits to families. Reliable change on six or more indicators of parent or child functioning was predicted by attendance and parent education. This study provides positive evidence for the effectiveness of group music therapy in promoting improved parental mental health, positive parenting and key child developmental areas.

  6. Mathematical phantoms for evaluation of age-specific internal dose

    International Nuclear Information System (INIS)

    Cristy, M.

    1980-01-01

    A series of mathematical phantoms representing children has been developed for use with photon transport codes. These phantoms, patterned after the Fisher-Snyder adult phantom, consist of simple mathematical expressions for the boundaries of the major organs and body sections. The location and shape of the organs are consistent with drawings depicting developmental anatomy, with the organ volumes assigned such that the masses at the various ages conform closely with the data presented in Reference Man. The explicit mathematical expressions for the various ages overcome the potential misrepresentation of organ sizes that occurred in phantoms derived from simple mathematical transformations of the adult phantom. Female breast tissue has been added to the phantoms, including the adult, now allowing assessment of doses to this organ

  7. Food allergy knowledge, attitudes and beliefs: Focus groups of parents, physicians and the general public

    Directory of Open Access Journals (Sweden)

    Barnathan Julia A

    2008-09-01

    Full Text Available Abstract Background Food allergy prevalence is increasing in US children. Presently, the primary means of preventing potentially fatal reactions are avoidance of allergens, prompt recognition of food allergy reactions, and knowledge about food allergy reaction treatments. Focus groups were held as a preliminary step in the development of validated survey instruments to assess food allergy knowledge, attitudes, and beliefs of parents, physicians, and the general public. Methods Eight focus groups were conducted between January and July of 2006 in the Chicago area with parents of children with food allergy (3 groups, physicians (3 groups, and the general public (2 groups. A constant comparative method was used to identify the emerging themes which were then grouped into key domains of food allergy knowledge, attitudes, and beliefs. Results Parents of children with food allergy had solid fundamental knowledge but had concerns about primary care physicians' knowledge of food allergy, diagnostic approaches, and treatment practices. The considerable impact of children's food allergies on familial quality of life was articulated. Physicians had good basic knowledge of food allergy but differed in their approach to diagnosis and advice about starting solids and breastfeeding. The general public had wide variation in knowledge about food allergy with many misconceptions of key concepts related to prevalence, definition, and triggers of food allergy. Conclusion Appreciable food allergy knowledge gaps exist, especially among physicians and the general public. The quality of life for children with food allergy and their families is significantly affected.

  8. Analysis of a support group for children of parents with mental illnesses: managing stressful situations.

    Science.gov (United States)

    Gladstone, Brenda M; McKeever, Patricia; Seeman, Mary; Boydell, Katherine M

    2014-09-01

    We report an ethnographic analysis of a psycho-education and peer-support program for school-aged children of parents with mental illnesses. We conducted a critical discourse analysis of the program manual and observed group interactions to understand whether children shared program goals predetermined by adults, and how, or if, the intervention was responsive to their needs. Children were expected to learn mental illness information because "knowledge is power," and to express difficult feelings about being a child of a mentally ill parent that was risky. Participants used humor to manage group expectations, revealing how they made sense of their parents' problems, as well as their own. Suggestions are made for determining good mental health literacy based on children's preferences for explaining circumstances in ways they find relevant, and for supporting children's competencies to manage relationships that are important to them. © The Author(s) 2014.

  9. Construction of Korean adult voxel phantoms for radiation dosimetry and their applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik

    2002-08-15

    Although contribution of the MIRD-type mathematical anthropomorphic phantoms to computational radiation dosimetry, especially in determining the effective dose to the exposed personnel, is very significant, there remain some questions on possible deviation in the resulting dosimetric quantities from the true values. This is particularly the case for those organ or tissues having complicated geometry difficult to model with simple geometrical body elements. As an alternative approach to resolve the problem, there have been efforts to use voxel phantoms, which can very precisely describe both the external shape and the internal organs by virtue of fast advances in medical imaging technology as well as in computing power. In this study, Korean adult male and female voxel phantoms were constructed by processing whole-body MR images of healthy volunteers who belong to middle group of Korean in height and weight. Organs and tissues on tomographic images were manually segmented and indexed using the graphic software PL-400 . Due to limited resolution of the raw MR images, voxels of rather large size, 2 mmx2 mmx8 mm for the woman and 2mmx2mmx10mm for the man, were used. The resulting male and female voxel phantoms were named KRMAN and KRWOMAN, respectively. To assess utility of the voxel phatoms, calculations were carried out with the Monte Carlo code MCNP4B for two illustrative problems. A program VOXELMAKER1.0 was developed to convert the voxel phantom data into MCNP geometry input format. In the first example, organ equivalent doses and effective doses were evaluated for phantoms in broad parallel photon fields of different energies and directions and were compared to corresponding values given in ICRP 74 which were derived with the MIRD-type phantoms. No significant deviations between MIRD and voxel phantoms were found in the effective doses. Significant differences up to around factor of 2, however, were observed in organ equivalent doses for some organs including

  10. Usefulness of a functional tracheobronchial phantom for interventional procedure

    International Nuclear Information System (INIS)

    Kim, Tae Hyung; Lim, Cheong Hwan; Kim, Jeong Koo

    2003-01-01

    To evaluate usefulness of a functional tracheobronchial phantom for interventional procedure. The functional phantom was made as a actual size with human normal anatomy used silicone and a paper clay mold. A tracheobronchial-shape clay mold was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed. We measured film density and tracheobronchial angle at the human, animal and phantom respectively. The film density of trachea part were 0.76 (± 0.011) in human, 0.97 (± 0.015) in animal, 0.45 (± 0.016) in phantom. The tracheobronchial bifurcation part measured 0.51 (± 0.006) in human, 0.65 (± 0.005) in animal, 0.65 (± 0.008) in phantom. The right bronchus part measured 0.14 (± 0.008) in human, 0.59 (± 0.014) in animal and 0.04 (± 0.007) in phantom. The left bronchus were 0.54 (± 0.004) in human, 0.54 (± 0.008) in animal and 0.08 (± 0.008) in phantom. At the stent part were 0.54 (± 0.004) in human, 0.59 (± 0.011) in animal and 0.04 (± 0.007) in phantom, respectively. The tracheobronchial angle of the left bronchus site were 42.6 (± 2.07).deg. in human, 43.4 (± 2.40).deg. in animal and 35 (± 2.00).deg. in phantom, respectively. The right bronchus site were 32.8 (± 2.77).deg. in human, 34.6 (± 1.94).deg. in animal and 50.2 (± 1.30).deg. in phantom, respectively. The phantom was useful for in-vitro testing of tracheobronchial interventional procedure, since it was easy to reproduce

  11. Parental illness perceptions and medication perceptions in childhood asthma, a focus group study

    NARCIS (Netherlands)

    Klok, Ted; Brand, Paul L.; Bomhof-Roordink, Hanna; Duiverman, Eric J.; Kaptein, Adrian A.

    Aim: Asthma treatment according to guidelines fails frequently, through patients' nonadherence to doctors' advice. This study aimed to explore how differences in asthma care influence parents' perceptions to inhaled corticosteroids (ICS). Methods: We conducted six semistructured focus groups,

  12. Consumer evaluation and satisfaction with individual versus group parent training for children with hyperkinetic disorder (HKD).

    Science.gov (United States)

    Heubeck, Bernd G; Otte, Thomas A; Lauth, Gerhard W

    2016-09-01

    The objective of this study was to investigate the social validity of cognitive-behavioural parent training (CBPT) delivered in two formats to parents who have children with hyperkinetic disorder (HKD) with and without medication. Compared individual with group treatment as part of a multicentre randomized controlled trial. Obtained a broad range of evaluations and satisfaction ratings post-treatment and related them to pre-treatment and treatment factors. Attendance rates were high in the individual and slightly less in the group training. Levels of satisfaction were high in both treatment arms with large numbers rating the outcomes, the trainers and the overall training very favourably. Medication showed no effect on parental evaluations. Evaluation of outcomes and satisfaction with the trainer emerged as strong predictors of overall programme satisfaction. The social validity of cognitive-behavioural parent training for hyperkinetic children was supported by high levels of treatment acceptability across a range of indicators and for children with and without medication. Both forms of treatment delivery lead to high rates of consumer satisfaction. Consumer evaluations of CBPT appear independent of medication for HKD. Course satisfaction is clearly associated with two factors that trainers can affect: The parent-trainer relationship and parents' sense of achievement. Far more mothers than fathers attended the trainings. Attitudes may differ in other cultures. © 2015 The British Psychological Society.

  13. Tissue Equivalent Phantom Design for Characterization of a Coherent Scatter X-ray Imaging System

    Science.gov (United States)

    Albanese, Kathryn Elizabeth

    Scatter in medical imaging is typically cast off as image-related noise that detracts from meaningful diagnosis. It is therefore typically rejected or removed from medical images. However, it has been found that every material, including cancerous tissue, has a unique X-ray coherent scatter signature that can be used to identify the material or tissue. Such scatter-based tissue-identification provides the advantage of locating and identifying particular materials over conventional anatomical imaging through X-ray radiography. A coded aperture X-ray coherent scatter spectral imaging system has been developed in our group to classify different tissue types based on their unique scatter signatures. Previous experiments using our prototype have demonstrated that the depth-resolved coherent scatter spectral imaging system (CACSSI) can discriminate healthy and cancerous tissue present in the path of a non-destructive x-ray beam. A key to the successful optimization of CACSSI as a clinical imaging method is to obtain anatomically accurate phantoms of the human body. This thesis describes the development and fabrication of 3D printed anatomical scatter phantoms of the breast and lung. The purpose of this work is to accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Tissue-equivalent anatomical phantoms were designed to assess the capability of the CACSSI system to classify different types of breast tissue (adipose, fibroglandular, malignant). These phantoms were 3D printed based on DICOM data obtained from CT scans of prone breasts. The phantoms were tested through comparison of measured scatter signatures with those of adipose and fibroglandular tissue from literature. Tumors in the phantom were modeled using a variety of biological tissue including actual surgically excised benign and malignant tissue specimens. Lung based phantoms have also been printed for future

  14. Online information for parents caring for their premature baby at home: A focus group study and systematic web search.

    Science.gov (United States)

    Alderdice, Fiona; Gargan, Phyl; McCall, Emma; Franck, Linda

    2018-01-30

    Online resources are a source of information for parents of premature babies when their baby is discharged from hospital. To explore what topics parents deemed important after returning home from hospital with their premature baby and to evaluate the quality of existing websites that provide information for parents post-discharge. In stage 1, 23 parents living in Northern Ireland participated in three focus groups and shared their information and support needs following the discharge of their infant(s). In stage 2, a World Wide Web (WWW) search was conducted using Google, Yahoo and Bing search engines. Websites meeting pre-specified inclusion criteria were reviewed using two website assessment tools and by calculating a readability score. Website content was compared to the topics identified by parents in the focus groups. Five overarching topics were identified across the three focus groups: life at home after neonatal care, taking care of our family, taking care of our premature baby, baby's growth and development and help with getting support and advice. Twenty-nine sites were identified that met the systematic web search inclusion criteria. Fifteen (52%) covered all five topics identified by parents to some extent and 9 (31%) provided current, accurate and relevant information based on the assessment criteria. Parents reported the need for information and support post-discharge from hospital. This was not always available to them, and relevant online resources were of varying quality. Listening to parents needs and preferences can facilitate the development of high-quality, evidence-based, parent-centred resources. © 2018 The Authors Health Expectations published by John Wiley & Sons Ltd.

  15. Phantom Pain

    Science.gov (United States)

    ... Because this is yet another version of tangled sensory wires, the result can be pain. A number of other factors are believed to contribute to phantom pain, including damaged nerve endings, scar tissue at the site of the amputation and the physical memory of pre-amputation pain in the affected area. ...

  16. Good-parent beliefs of parents of seriously ill children.

    Science.gov (United States)

    Feudtner, Chris; Walter, Jennifer K; Faerber, Jennifer A; Hill, Douglas L; Carroll, Karen W; Mollen, Cynthia J; Miller, Victoria A; Morrison, Wynne E; Munson, David; Kang, Tammy I; Hinds, Pamela S

    2015-01-01

    Parents' beliefs about what they need to do to be a good parent when their children are seriously ill influence their medical decisions, and better understanding of these beliefs may improve decision support. To assess parents' perceptions regarding the relative importance of 12 good-parent attributes. A cross-sectional, discrete-choice experiment was conducted at a children's hospital. Participants included 200 parents of children with serious illness. Ratings of 12 good-parent attributes, with subsequent use of latent class analysis to identify groups of parents with similar ratings of attributes, and ascertainment of whether membership in a particular group was associated with demographic or clinical characteristics. The highest-ranked good-parent attribute was making sure that my child feels loved, followed by focusing on my child's health, making informed medical care decisions, and advocating for my child with medical staff. We identified 4 groups of parents with similar patterns of good-parent-attribute ratings, which we labeled as: child feels loved (n=68), child's health (n=56), advocacy and informed (n=55), and spiritual well-being (n=21). Compared with the other groups, the child's health group reported more financial difficulties, was less educated, and had a higher proportion of children with new complex, chronic conditions. Parents endorse a broad range of beliefs that represent what they perceive they should do to be a good parent for their seriously ill child. Common patterns of how parents prioritize these attributes exist, suggesting future research to better understand the origins and development of good-parent beliefs among these parents. More important, engaging parents individually regarding what they perceive to be the core duties they must fulfill to be a good parent may enable more customized and effective decision support.

  17. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Yang, Jie [Pinnacle Health - Fox Chase Regional Cancer Center, Harrisburg, Pennsylvania 17109 (United States)

    2014-09-15

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm{sup 3} Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT.

  18. A study of the short- to long-phantom dose ratios for CT scanning without table translation

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob; Yang, Jie

    2014-01-01

    Purpose: For CT scanning in the stationary-table modes, AAPM Task Group 111 proposed to measure the midpoint dose on the central and peripheral axes of sufficiently long phantoms. Currently, a long cylindrical phantom is usually not available in many clinical facilities. The use of a long phantom is also challenging because of the heavy weight. In order to shed light on assessing the midpoint dose in CT scanning without table movement, the authors present a study of the short- to long-phantom dose ratios, and perform a cross-comparison of CT dose ratios on different scanner models. Methods: The authors performed Geant4-based Monte Carlo simulations with a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare), and modeled dosimetry measurements using a 0.6 cm 3 Farmer type chamber and a 10-cm long pencil ion chamber. The short (15 cm) to long (90 cm) phantom dose ratios were computed for two PMMA diameters (16 and 32 cm), two phantom axes (the center and the periphery), and a range of beam apertures (3–25 cm). The results were compared with the published data of previous studies with other multiple detector CT (MDCT) scanners and cone beam CT (CBCT) scanners. Results: The short- to long-phantom dose ratios changed with beam apertures but were insensitive to beam qualities (80–140 kV, the head and body bowtie filters) and MDCT and CBCT scanner models. Conclusions: The short- to long-phantom dose ratios enable medical physicists to make dosimetry measurements using the standard CT dosimetry phantoms and a Farmer chamber or a 10 cm long pencil chamber, and to assess the midpoint dose in long phantoms. This method provides an effective approach for the dosimetry of CBCT scanning in the stationary-table modes, and is useful for perfusion and interventional CT

  19. Modifying the 'Positive Parenting Program' for parents with intellectual disabilities.

    Science.gov (United States)

    Glazemakers, I; Deboutte, D

    2013-07-01

    Many parents with intellectual disabilities (ID) want and/or need professional guidance and support to learn skills and strategies to prevent and manage child behaviour problems. However, the available support is rarely suitable, and suitable support is rarely available. The aim of this study was to determine whether a popular mainstream parenting training programme, known as 'Group Triple P' (Positive Parenting Program), could be successfully modified for this parent group. A pilot study was undertaken to determine whether a modified version of Group Triple P would engage and retain parents with ID. A non-experimental, pre-test post-test study, involving a total of 30 parents with ID, was then undertaken to obtain preliminary efficacy data. Parent engagement and participation levels were high. No parent 'dropped out' of the programme. After completing the modified Group Triple P programme, parents reported a decrease in psychological distress, maladaptive parenting and child conduct problems. Parents reported high levels of satisfaction with the information and support they received. Research-informed adaptation of mainstream behavioural family interventions, such as Group Triple P, could make 'suitable support' more readily available, and more engaging for parents with ID. © 2012 The Authors. Journal of Intellectual Disability Research © 2012 John Wiley & Sons Ltd, MENCAP & IASSID.

  20. Comparison of different phantoms used in digital diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bor, Dogan, E-mail: bor@eng.ankara.edu.tr [Ankara University, Faculty of Engineering, Department of Engineering Physics. Tandogan, 06100 Ankara (Turkey); Unal, Elif, E-mail: elf.unall@gmail.com [Radat Dosimetry Laboratory Services, 06830, Golbasi, Ankara (Turkey); Uslu, Anil, E-mail: m.aniluslu@gmail.com [Radat Dosimetry Laboratory Services, 06830, Golbasi, Ankara (Turkey)

    2015-09-21

    The organs of extremity, chest, skull and lumbar were physically simulated using uniform PMMA slabs with different thicknesses alone and using these slabs together with aluminum plates and air gaps (ANSI Phantoms). The variation of entrance surface air kerma and scatter fraction with X-ray beam qualities was investigated for these phantoms and the results were compared with those measured from anthropomorphic phantoms. A flat panel digital radiographic system was used for all the experiments. Considerable variations of entrance surface air kermas were found for the same organs of different designs, and highest doses were measured for the PMMA slabs. A low contrast test tool and a contrast detail test object (CDRAD) were used together with each organ simulation of PMMA slabs and ANSI phantoms in order to test the clinical image qualities. Digital images of these phantom combinations and anthropomorphic phantoms were acquired in raw and clinically processed formats. Variation of image quality with kVp and post processing was evaluated using the numerical metrics of these test tools and measured contrast values from the anthropomorphic phantoms. Our results indicated that design of some phantoms may not be efficient enough to reveal the expected performance of the post processing algorithms.

  1. The Moderating Role of Parental Warmth on the Relation Between Verbal Punishment and Child Problem Behaviors for Same-sex and Cross-sex Parent-Child Groups

    Science.gov (United States)

    Anonas, Maria Roberta L.; Alampay, Liane Peña

    2015-01-01

    This study investigates the relation between parental verbal punishment and externalizing and internalizing behavior problems in Filipino children, and the moderating role of parental warmth in this relation, for same-sex (mothers-girls; fathers-boys) and cross-sex parent-child groups (mothers-boys; fathers-girls). Measures used were the Rohner Parental Acceptance-Rejection and Control Scale (PARQ/Control), the Achenbach Child Behavior Checklist (CBC), and a discipline measure (DI) constructed for the study. Participants were 117 mothers and 98 fathers of 61 boys and 59 girls who responded to a discipline interview, the Parental Acceptance-Rejection and Control scale (PARQ/Control) and the Achenbach Child Behavior Checklist via oral interviews. Hierarchical multiple regression analyses (with Bonferroni-corrected alpha levels) revealed that maternal frequency of verbal punishment was positively related to internalizing and externalizing outcomes in boys and girls whereas paternal frequency of verbal punishment was positively related to girls’ externalizing behavior. Significant interactions between verbal punishment and maternal warmth in mother-girl groups were also found for both internalizing and externalizing behaviors. While higher maternal warmth ameliorated the impact of low verbal punishment on girls’ internalizing and externalizing behaviors, it exacerbated the effect of high verbal punishment on negative outcomes. PMID:26752797

  2. Perceived Peer and Parent Out-Group Norms, Cultural Identity, and Adolescents' Reasoning About Peer Intergroup Exclusion.

    Science.gov (United States)

    Brenick, Alaina; Romano, Kelly

    2016-09-01

    Cultural group identity and group norms are significantly related to social exclusion evaluations (Bennett, ). This study examined 241 Jewish-American mid (M = 14.18 years, SD = 0.42) to late (M = 17.21 years, SD = 0.43; MageTOTAL  = 15.54 years, SD = 1.57) adolescents' cultural identities and contextually salient perceived group norms in relation to their evaluations of Arab-American inclusion and exclusion across two contexts (peers vs. family at home). Results suggest that perceived group norms are related to the context in which they are applied: parents in the home and peers in the peer context. Peers remained a significant source of perceived group norms in the home context. Significant interactions emerged between perceived parent group norms and cultural identity. Findings highlight the need to address group-specific norms by context to ensure maximum effectiveness for intergroup interventions. © 2016 The Authors. Child Development © 2016 Society for Research in Child Development, Inc.

  3. A Parent-Only Group Intervention for Children with Anxiety Disorders: Pilot Study

    Science.gov (United States)

    Thienemann, Margo; Moore, Phoebe; Tompkins, Kim

    2006-01-01

    Objective: Working to optimize treatment outcome and use resources efficiently, investigators conducted the first test of an existing parent-only group cognitive-behavioral therapy protocol to treat 24 children 7 to 16 years old with primary anxiety disorder diagnoses. Method: Over the course of 7 months, the authors evaluated a manual-based…

  4. All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry.

    Science.gov (United States)

    Kramer, R; Khoury, H J; Vieira, J W; Loureiro, E C M; Lima, V J M; Lima, F R A; Hoff, G

    2004-12-07

    The International Commission on Radiological Protection (ICRP) has created a task group on dose calculations, which, among other objectives, should replace the currently used mathematical MIRD phantoms by voxel phantoms. Voxel phantoms are based on digital images recorded from scanning of real persons by computed tomography or magnetic resonance imaging (MRI). Compared to the mathematical MIRD phantoms, voxel phantoms are true to the natural representations of a human body. Connected to a radiation transport code, voxel phantoms serve as virtual humans for which equivalent dose to organs and tissues from exposure to ionizing radiation can be calculated. The principal database for the construction of the FAX (Female Adult voXel) phantom consisted of 151 CT images recorded from scanning of trunk and head of a female patient, whose body weight and height were close to the corresponding data recommended by the ICRP in Publication 89. All 22 organs and tissues at risk, except for the red bone marrow and the osteogenic cells on the endosteal surface of bone ('bone surface'), have been segmented manually with a technique recently developed at the Departamento de Energia Nuclear of the UFPE in Recife, Brazil. After segmentation the volumes of the organs and tissues have been adjusted to agree with the organ and tissue masses recommended by ICRP for the Reference Adult Female in Publication 89. Comparisons have been made with the organ and tissue masses of the mathematical EVA phantom, as well as with the corresponding data for other female voxel phantoms. The three-dimensional matrix of the segmented images has eventually been connected to the EGS4 Monte Carlo code. Effective dose conversion coefficients have been calculated for exposures to photons, and compared to data determined for the mathematical MIRD-type phantoms, as well as for other voxel phantoms.

  5. Energy Efficient Resource Allocation for Phantom Cellular Networks

    KAUST Repository

    Abdelhady, Amr

    2016-04-01

    Multi-tier heterogeneous networks have become an essential constituent for next generation cellular networks. Meanwhile, energy efficiency (EE) has been considered a critical design criterion along with the traditional spectral efficiency (SE) metric. In this context, we study power and spectrum allocation for the recently proposed two-tier network architecture known as phantom cellular networks. The optimization framework includes both EE and SE. First, we consider sparsely deployed cells experiencing negligible interference and assume perfect channel state information (CSI). For this setting, we propose an algorithm that finds the SE and EE resource allocation strategies. Then, we compare the performance of both design strategies versus number of users, and phantom cells share of the total available resource units (RUs). We aim to investigate the effect of some system parameters to achieve improved SE performance at a non-significant loss in EE performance, or vice versa. It is found that increasing phantom cells share of RUs decreases the SE performance loss due to EE optimization when compared with the optimized SE performance. Second, we consider the densely deployed phantom cellular networks and model the EE optimization problem having into consideration the inevitable interference and imperfect channel estimation. To this end, we propose three resource allocation strategies aiming at optimizing the EE performance metric of this network. Furthermore, we investigate the effect of changing some of the system parameters on the performance of the proposed strategies, such as phantom cells share of RUs, number of deployed phantom cells within a macro cell coverage, number of pilots and the maximum power available for transmission by the phantom cells BSs. It is found that increasing the number of pilots deteriorates the EE performance of the whole setup, while increasing maximum power available for phantom cells transmissions reduces the EE of the whole setup in a

  6. A cognitive behavioral based group intervention for children with a chronic illness and their parents: a multicentre randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Schuengel Carlo

    2011-07-01

    Full Text Available Abstract Background Coping with a chronic illness (CI challenges children's psychosocial functioning and wellbeing. Cognitive-behavioral intervention programs that focus on teaching the active use of coping strategies may prevent children with CI from developing psychosocial problems. Involvement of parents in the intervention program may enhance the use of learned coping strategies in daily life, especially on the long-term. The primary aim of the present study is to examine the effectiveness of a cognitive behavioral based group intervention (called 'Op Koers' 1 for children with CI and of a parallel intervention for their parents. A secondary objective is to investigate why and for whom this intervention works, in order to understand the underlying mechanisms of the intervention effect. Methods/design This study is a multicentre randomized controlled trial. Participants are children (8 to 18 years of age with a chronic illness, and their parents, recruited from seven participating hospitals in the Netherlands. Participants are randomly allocated to two intervention groups (the child intervention group and the child intervention combined with a parent program and a wait-list control group. Primary outcomes are child psychosocial functioning, wellbeing and child disease related coping skills. Secondary outcomes are child quality of life, child general coping skills, child self-perception, parental stress, quality of parent-child interaction, and parental perceived vulnerability. Outcomes are evaluated at baseline, after 6 weeks of treatment, and at a 6 and 12-month follow-up period. The analyses will be performed on the basis of an intention-to-treat population. Discussion This study evaluates the effectiveness of a group intervention improving psychosocial functioning in children with CI and their parents. If proven effective, the intervention will be implemented in clinical practice. Strengths and limitations of the study design are discussed

  7. Comparative Effects of Mindfulness and Support and Information Group Interventions for Parents of Adults with Autism Spectrum Disorder and Other Developmental Disabilities

    Science.gov (United States)

    Lunsky, Yona; Hastings, Richard P.; Weiss, Jonathan A.; Palucka, Anna M.; Hutton, Sue; White, Karen

    2017-01-01

    This study evaluated two community based interventions for parents of adults with autism spectrum disorder and other developmental disabilities. Parents in the mindfulness group reported significant reductions in psychological distress, while parents in the support and information group did not. Reduced levels of distress in the mindfulness group…

  8. [Psychotherapies for the Treatment of Phantom Limb Pain].

    Science.gov (United States)

    Cárdenas, Katherine; Aranda, Mariana

    The phantom limb pain has been described as a condition in which patients experience a feeling of itching, spasm or pain in a limb or body part that has been previously amputated. Such pain can be induced by a conflict between the representation of the visual and proprioceptive feedback of the previously healthy limb. The phantom limb pain occurs in at least 42 to 90% of amputees. Regular drug treatment of phantom limb pain is almost never effective. A systematic review of the literature was conducted in Medline and Cochrane using the MESH terms "phantom limb pain" and "psychotherapy", published in the last 10 years, in English and Spanish, finding 49 items. After reviewing the abstracts, 25 articles were excluded for not being related to the objective of the research. Additionally cross references of included articles and literature were reviewed. To describe the psychotherapies used in the management of phantom limb pain, their effectiveness and clinical application reported in the literature. The mechanisms underlying phantom limb pain were initially explained, as were the published studies on the usefulness of some psychotherapies such as mirror visual feedback and immersive virtual reality, visual imagery, desensitization and reprocessing eye movements and hypnosis. The phantom limb pain is a complex syndrome that requires pharmacological and psychotherapeutic intervention. The psychotherapies that have been used the most as adjuvants in the treatment of phantom limb pain are mirror visual feedback, desensitization and reprocessing eye movements, imagery and hypnosis. Studies with more representative samples, specifically randomized trials are required. Copyright © 2016 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  9. Primary motor cortex changes after amputation correlate with phantom limb pain and the ability to move the phantom limb

    DEFF Research Database (Denmark)

    Raffin, Estelle; Richard, Nathalie; Giraux, Pascal

    2016-01-01

    A substantial body of evidence documents massive reorganization of primary sensory and motor cortices following hand amputation, the extent of which is correlated with phantom limb pain. Many therapies for phantom limb pain are based upon the idea that plastic changes after amputation...... for the maladaptative plasticity model, we demonstrate for the first time that motor capacities of the phantom limb correlate with post-amputation reorganization, and that this reorganization is not limited to the face and hand representations but also includes the proximal upper-limb....

  10. The UF family of reference hybrid phantoms for computational radiation dosimetry

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lodwick, Daniel; Hurtado, Jorge; Pafundi, Deanna; Williams, Jonathan L; Bolch, Wesley E

    2010-01-01

    Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR(TM). NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros(TM). The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference

  11. Development of thyroid anthropomorphic phantoms for use in nuclear medicine

    International Nuclear Information System (INIS)

    Cerqueira, R.A.D.; Maia, A.F.

    2014-01-01

    The objective of this study was to develop thyroid anthropomorphic phantoms to be used in control tests of medical images in scintillation cameras. The main difference among the phantoms was the neck shape: in the first, called OSCT, it was geometrically shaped, while in the second, called OSAP, it was anthropomorphically shaped. In both phantoms, thyroid gland prototypes, which were made of acrylic and anthropomorphically shaped, were constructed to allow the simulation of a healthy thyroid and of thyroids with hyperthyroidism and hypothyroidism. Images of these thyroid anthropomorphic phantoms were obtained using iodine 131 with an activity of 8.695 MBq. The iodine 131 was chosen because it is widely used in studies of thyroid scintigraphy. The images obtained proved the effectiveness of the phantoms to simulate normal or abnormal thyroids function. These phantoms can be used in medical imaging quality control programs and, also in the training of professionals involved in the analysis of images in nuclear medicine centers. - Highlights: ► Two thyroid phantoms were developed (OSCT and OSAP) with different types of acrylics. ► Thyroid glands were represented anthropomorphically in the both phantoms. ► Different prototypes of thyroid were built of simulate healthy or unhealthy glands. ► Images indicate that anthropomorphic phantoms correctly simulate the thyroid gland

  12. Group-based parent-training programmes for improving emotional and behavioural adjustment in children from birth to three years old.

    Science.gov (United States)

    Barlow, Jane; Smailagic, Nadja; Ferriter, Michael; Bennett, Cathy; Jones, Hannah

    2010-03-17

    Emotional and behavioural problems in children are common. Research suggests that parenting has an important role to play in helping children to become well-adjusted, and that the first few months and years are especially important. Parenting programmes may have a role to play in improving the emotional and behavioural adjustment of infants and toddlers. This review is applicable to parents and carers of children up to three years eleven months although some studies included children up to five years old. To:a) establish whether group-based parenting programmes are effective in improving the emotional and behavioural adjustment of children three years of age or less (i.e. maximum mean age of 3 years 11 months); b) assess the role of parenting programmes in the primary prevention of emotional and behavioural problems. We searched CENTRAL, MEDLINE, EMBASE, CINAHL, PsycINFO, Sociofile, Social Science Citation Index, ASSIA, National Research Register (NRR) and ERIC. The searches were originally run in 2000 and then updated in 2007/8. Randomised controlled trials of group-based parenting programmes that had used at least one standardised instrument to measure emotional and behavioural adjustment. The results for each outcome in each study have been presented, with 95% confidence intervals. Where appropriate the results have been combined in a meta-analysis using a random-effects model. Eight studies were included in the review. There were sufficient data from six studies to combine the results in a meta-analysis for parent-reports and from three studies to combine the results for independent assessments of children's behaviour post-intervention. There was in addition, sufficient information from three studies to conduct a meta-analysis of both parent-report and independent follow-up data. Both parent-report (SMD -0.25; CI -0.45 to -0.06), and independent observations (SMD -0.54; CI -0.84 to -0.23) of children's behaviour produce significant results favouring the

  13. Surface-enhanced Raman spectroscopic monitor of triglyceride hydrolysis in a skin pore phantom

    Science.gov (United States)

    Weldon, Millicent K.; Morris, Michael D.

    1999-04-01

    Bacterial hydrolysis of triglycerides is followed in a sebum probe phantom by microprobe surface-enhanced Raman scattering (SERS) spectroscopy. The phantom consists of a purpose-built syringe pump operating at physiological flow rates connected to a 300 micron i.d. capillary. We employ silicon substrate SERS microprobes to monitor the hydrolysis products. The silicon support allows some tip flexibility that makes these probes ideal for insertion into small structures. Propionibacterium acnes are immobilized on the inner surface of the capillary. These bacteria hydrolyze the triglycerides in a model sebum emulsion flowing through the capillary. The transformation is followed in vitro as changes in the SERS caused by hydrolysis of triglyceride to fatty acid. The breakdown products consists of a mixture of mono- and diglycerides and their parent long chain fatty acids. The fatty acids adsorb as their carboxylates and can be readily identified by their characteristic spectra. The technique can also confirm the presence of bacteria by detection of short chain carboxylic acids released as products of glucose fermentation during the growth cycle of these cells. Co-adsorption of propionate is observed. Spatial localization of the bacteria is obtained by ex-situ line imaging of the probe.

  14. Measurement of TLD Albedo response on various calibration phantoms

    International Nuclear Information System (INIS)

    Momose, T.; Tsujimura, N.; Shinohara, K.; Ishiguro, H.; Nakamura, T.

    1996-01-01

    The International Commission on Radiation Units and Measurements (ICRU) has recommended that individual dosemeter should be calibrated on a suitable phantom and has pointed out that the calibration factor of a neutron dosemeter is strongly influenced by the the exact size and shape of the body and the phantom to which the dosemeter is attached. As the principle of an albedo type thermoluminescent personal dosemeter (albedo TLD) is essentially based on a detection of scattered and moderated neutron from a human body, the sensitivity of albedo TLD is strongly influenced by the incident neutron energy and the calibration phantom. (1) Therefore for albedo type thermoluminescent personal dosemeter (albedo TLD), the information of neutron albedo response on the calibration phantom is important for appropriate dose estimation. In order to investigate the effect of phantom type on the reading of the albedo TLD, measurement of the TLD energy response and angular response on some typical calibration phantoms was performed using dynamitron accelerator and 252 Cf neutron source. (author)

  15. Agency over Phantom Limb Enhanced by Short-Term Mirror Therapy.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2017-01-01

    Most amputees experience phantom limb, whereby they feel that the amputated limb is still present. In some cases, these experiences include pain that can be alleviated by "mirror therapy." Mirror therapy consists of superimposing a mirrored image of the moving intact limb onto the phantom limb. This therapy provides a closed loop between the motor command to the amputated limb and its predicted visual feedback. This loop is also involved in the sense of agency, a feeling of controlling one's own body. However, it is unclear how mirror therapy is related to the sense of agency over a phantom limb. Using mirror therapy, we investigated phantom limb pain and the senses of agency and ownership (i.e., a feeling of having one's own body) of the phantom limb. Nine upper-limb amputees, five of whom reported recent phantom limb pain, underwent a single 15-min trial of mirror therapy. Before and after the trial, the participants completed a questionnaire regarding agency, ownership, and pain related to their phantom limb. They reported that the sense of agency over the phantom limb increased following the mirror therapy trial, while the ownership slightly increased but not as much as did the agency. The reported pain did not change; that is, it was comparably mild before and after the trial. These results suggest that short-term mirror therapy can, at least transiently, selectively enhance the sense of agency over a phantom limb, but may not alleviate phantom limb pain.

  16. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    International Nuclear Information System (INIS)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S.

    2015-01-01

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed

  17. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Bieniosek, Matthew F. [Department of Electrical Engineering, Stanford University, 350 Serra Mall, Stanford, California 94305 (United States); Lee, Brian J. [Department of Mechanical Engineering, Stanford University, 440 Escondido Mall, Stanford, California 94305 (United States); Levin, Craig S., E-mail: cslevin@stanford.edu [Departments of Radiology, Physics, Bioengineering and Electrical Engineering, Stanford University, 300 Pasteur Dr., Stanford, California 94305-5128 (United States)

    2015-10-15

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed

  18. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    Science.gov (United States)

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to

  19. The Effectiveness of a Group Triple P with Chinese Parents Who Have a Child with Developmental Disabilities: A Randomized Controlled Trial

    Science.gov (United States)

    Leung, Cynthia; Fan, Angel; Sanders, Matthew R.

    2013-01-01

    The study examined the effectiveness of Group Triple P, a Level 4 variant of the Triple P multilevel system of parenting support, with Chinese parents who had a preschool aged child with a developmental disability, using randomized controlled trial design. Participants (Intervention group: 42; Waitlist Control group: 39) completed measures on…

  20. Stage-related behavioural problems in the 1-4 year old child: parental expectations in a child development unit referral group compared with a control group.

    Science.gov (United States)

    Ticehurst, R L; Henry, R L

    1989-02-01

    Behavioural problems in preschool (1-4 years) children are a common cause of referral to health services. Parents of children presenting to the child development unit with behavioural problems (n = 18) were compared with a control group (n = 45). A questionnaire was utilized to examine the parents' expectations of the children's behaviours. As might be expected, the parents of children presenting to the Unit rated their children as having more difficult behaviours. These parents had unrealistic expectations, particularly for the 'negative' behaviours (disobedience, temper tantrums, defiance and whinging). However, they were able to anticipate normal age-related difficulties in some problem areas (dawdling during mealtimes, masturbating, not sharing toys and being jealous of one's siblings). Counselling should address the issue of matching the expectations of parents with the individual rates of development of their children.

  1. Children's Experiences and Meaning Construction on Parental Divorce: A Focus Group Study

    Science.gov (United States)

    Maes, Sofie D. J.; De Mol, Jan; Buysse, Ann

    2012-01-01

    The global aim of this study was to explore children's narratives of parental divorce. A convenience sample, composed of 11- and 14-year-old children, was recruited. A total of 22 children (12 male, 10 female) participated in this focus group study. The findings show that two components seem to be really important for children during the divorce…

  2. Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

    International Nuclear Information System (INIS)

    Choi, Da Hye; Choi, Bo Ram; Huh, Kyung Hoe; Heo, Min Suk; Choi, Soon Chul; Choi, Jin Woo; Yi, Won Jin; Lee, Sam Sun

    2013-01-01

    This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

  3. Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Da Hye; Choi, Bo Ram; Huh, Kyung Hoe; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Choi, Jin Woo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University, Cheonan (Korea, Republic of); Yi, Won Jin; Lee, Sam Sun [Dept. of Oral and Maxillofacial Radiology, BK21 Craniomaxillofacial Life Science, and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2013-03-15

    This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

  4. Outcomes of group-based treatment program with parental involvement for the management of childhood and adolescent obesity.

    Science.gov (United States)

    Santiprabhob, Jeerunda; Leewanun, Chanin; Limprayoon, Kawewan; Kiattisakthavee, Pornpimol; Wongarn, Renu; Aanpreung, Prapun; Likitmaskul, Supawadee

    2014-10-01

    An uncontrolled study was conducted to evaluate the effects of a group-based program on weight control, metabolic profiles, and obesity-related complications in obese youth. The program consisted of an initial in-patient session and five group sessions, one, two, three, six, and nine months into the study, providing participants and their parents with information about the consequences of obesity and lifestyle modifications. The severity of obesity and obesity-related complications were evaluated at baseline and 12 months after the intervention. The participants' and their parents' perceptions of the program were assessed. Of the obese youth recruited (n=126), 115 completed the study. Their percentage weight for height and percentage body fat decreased significantly (both pchildhood obesity, improving metabolic profiles, and alleviating certain obesity-related complications. A group-based program that provides education and raises the awareness of obese children and their parents about the consequences of obesity is an effective model for treating childhood obesity. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Design of a tracked ultrasound calibration phantom made of LEGO bricks

    Science.gov (United States)

    Walsh, Ryan; Soehl, Marie; Rankin, Adam; Lasso, Andras; Fichtinger, Gabor

    2014-03-01

    PURPOSE: Spatial calibration of tracked ultrasound systems is commonly performed using precisely fabricated phantoms. Machining or 3D printing has relatively high cost and not easily available. Moreover, the possibilities for modifying the phantoms are very limited. Our goal was to find a method to construct a calibration phantom from affordable, widely available components, which can be built in short time, can be easily modified, and provides comparable accuracy to the existing solutions. METHODS: We designed an N-wire calibration phantom made of LEGO® bricks. To affirm the phantom's reproducibility and build time, ten builds were done by first-time users. The phantoms were used for a tracked ultrasound calibration by an experienced user. The success of each user's build was determined by the lowest root mean square (RMS) wire reprojection error of three calibrations. The accuracy and variance of calibrations were evaluated for the calibrations produced for various tracked ultrasound probes. The proposed model was compared to two of the currently available phantom models for both electromagnetic and optical tracking. RESULTS: The phantom was successfully built by all ten first-time users in an average time of 18.8 minutes. It cost approximately $10 CAD for the required LEGO® bricks and averaged a 0.69mm of error in the calibration reproducibility for ultrasound calibrations. It is one third the cost of similar 3D printed phantoms and takes much less time to build. The proposed phantom's image reprojections were 0.13mm more erroneous than those of the highest performing current phantom model The average standard deviation of multiple 3D image reprojections differed by 0.05mm between the phantoms CONCLUSION: It was found that the phantom could be built in less time, was one third the cost, compared to similar 3D printed models. The proposed phantom was found to be capable of producing equivalent calibrations to 3D printed phantoms.

  6. Parent Training with High-Risk Immigrant Chinese Families: A Pilot Group Randomized Trial Yielding Practice-Based Evidence

    Science.gov (United States)

    Lau, Anna S.; Fung, Joey J.; Ho, Lorinda Y.; Liu, Lisa L.; Gudino, Omar G.

    2011-01-01

    We studied the efficacy and implementation outcomes of a culturally responsive parent training (PT) program. Fifty-four Chinese American parents participated in a wait-list controlled group randomized trial (32 immediate treatment, 22 delayed treatment) of a 14-week intervention designed to address the needs of high-risk immigrant families.…

  7. The influence of parenting on maladaptive cognitive schema: a cross-sectional research on a group of adults

    Directory of Open Access Journals (Sweden)

    Pellerone M

    2017-02-01

    Full Text Available Monica Pellerone,1 Calogero Iacolino,1 Giuseppe Mannino,2 Ivan Formica,3 Simona Maria Zabbara1 1Faculty of Human and Social Sciences, “Kore” University of Enna, Enna, Sicily, Italy; 2Department of Jurisprudence, “LUMSA” University, Rome, Italy; 3Department of Cognitive, Psychological, Pedagogical Sciences and Cultural Studies, University of Study of Messina, Messina, Sicily, Italy Background: The literature emphasizes the role of early interpersonal experiences in the development of cognitive vulnerability; in particular, interruptions in early family relationships, parental unavailability and dysfunctional parenting are potential evolutionary precursors to negative cognitive style and emotional disorders.Materials and methods: This study measured the relationship of retrospective ratings on parental bonding with cognitive patterns in a group of Italian adults. The objectives of this study were as follows: to analyze the influence of age and education level on cognitive domains; to verify whether being parents and living at home with parents affect both parenting style and cognitive domains; to investigate how the type of the maternal and paternal parenting independently affects cognitive styles; to measure the predictive variables for the use of cognitive dysfunctional patterns and to investigate age as a moderating variable of the relation between parenting styles and cognitive domains in a group of adult men and women. The research involved 209 adults (118 males and 91 females living in Sicily (Italy aged between 20 and 60 years (M = 37.52; SD = 11.42. The research lasted for 1 year. The instruments used were the Parental Bonding Instrument to measure the perception of parenting during childhood and the Young Schema Questionnaire-3 to investigate cognitive patterns.Results: Data show that being a younger adult male with mother’s parenting style characterized by a lower level of nurturance is predictive of the disconnection and

  8. Radiation dose verification using real tissue phantom in modern radiotherapy techniques

    International Nuclear Information System (INIS)

    Gurjar, Om Prakash; Mishra, S.P.; Bhandari, Virendra; Pathak, Pankaj; Patel, Prapti; Shrivastav, Garima

    2014-01-01

    In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real interior of patient body has variable and varying densities inside. In this study an attempt has been made to verify the physical dosimetry in actual human body scenario by using goat head as 'head phantom' and goat meat as 'tissue phantom'. The mean percentage variation between planned and measured doses was found to be 2.48 (standard deviation (SD): 0.74), 2.36 (SD: 0.77), 3.62 (SD: 1.05), and 3.31 (SD: 0.78) for three-dimensional conformal radiotherapy (3DCRT) (head phantom), intensity modulated radiotherapy (IMRT; head phantom), 3DCRT (tissue phantom), and IMRT (tissue phantom), respectively. Although percentage variations in case of head phantom were within tolerance limit (< ± 3%), but still it is higher than the results obtained by using commercially available phantoms. And the percentage variations in most of cases of tissue phantom were out of tolerance limit. On the basis of these preliminary results it is logical and rational to develop radiation dosimetry methods based on real human body and also to develop an artificial phantom which should truly represent the interior of human body. (author)

  9. Radiation dose verification using real tissue phantom in modern radiotherapy techniques

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2014-01-01

    Full Text Available In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real interior of patient body has variable and varying densities inside. In this study an attempt has been made to verify the physical dosimetry in actual human body scenario by using goat head as "head phantom" and goat meat as "tissue phantom". The mean percentage variation between planned and measured doses was found to be 2.48 (standard deviation (SD: 0.74, 2.36 (SD: 0.77, 3.62 (SD: 1.05, and 3.31 (SD: 0.78 for three-dimensional conformal radiotherapy (3DCRT (head phantom, intensity modulated radiotherapy (IMRT; head phantom, 3DCRT (tissue phantom, and IMRT (tissue phantom, respectively. Although percentage variations in case of head phantom were within tolerance limit (< ± 3%, but still it is higher than the results obtained by using commercially available phantoms. And the percentage variations in most of cases of tissue phantom were out of tolerance limit. On the basis of these preliminary results it is logical and rational to develop radiation dosimetry methods based on real human body and also to develop an artificial phantom which should truly represent the interior of human body.

  10. NURBS-based 3-d anthropomorphic computational phantoms for radiation dosimetry applications

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lodwick, Daniel; Lee, Choonik; Bolch, Wesley E.

    2007-01-01

    Computational anthropomorphic phantoms are computer models used in the evaluation of absorbed dose distributions within the human body. Currently, two classes of the computational phantoms have been developed and widely utilised for dosimetry calculation: (1) stylized (equation-based) and (2) voxel (image-based) phantoms describing human anatomy through the use of mathematical surface equations and 3-D voxel matrices, respectively. However, stylized phantoms have limitations in defining realistic organ contours and positioning as compared to voxel phantoms, which are themselves based on medical images of human subjects. In turn, voxel phantoms that have been developed through medical image segmentation have limitations in describing organs that are presented in low contrast within either magnetic resonance or computed tomography image. The present paper reviews the advantages and disadvantages of these existing classes of computational phantoms and introduces a hybrid approach to a computational phantom construction based on non-uniform rational B-Spline (NURBS) surface animation technology that takes advantage of the most desirable features of the former two phantom types. (authors)

  11. Regional heating patterns of RF hyperthermia applicators in phantoms

    International Nuclear Information System (INIS)

    Kantor, G.; Ruggera, P.S.; Samulski, T.V.

    1984-01-01

    An elliptical phantom (20 cm by 30 cm cross-section and 40 cm long) with a 1 cm fat layer filled with muscle material was used to compare the induced heating patterns of the NCDRH helical coil, a Henry Medical Magnetrode coil, both with a diameter of 35.6 cm, and the BSD Annular Phased Array System (APAS). Temperature profiles were taken in the midplane cross-sectional slice along the major and minor axes of the phantom. These profiles were measured with a Vitek thermistor probe and the associated specific absorption rates (SAR) were determined from this data. SAR curves for each applicator were obtained along the major and minor axes of the phantom. The depths of heating of the Magnetrode applicator are considerably smaller than those for the helical applicator. Heating patterns for the APAS can be highly variable and asymmetric depending on the frequency of operation and the location of the phantom within the APAS aperture. While the APAS requires a water bolus for good coupling, the NCDRH and Magnetrode coils need only to be air coupled for good phantom coupling. Both the helical applicator and APAS can provide significant heating in the central region of the phantom. However, the heating of the helical coil does not critically depend on the phantom loading

  12. Food parenting measurement issues: Working group consensus report

    Science.gov (United States)

    Childhood obesity is a growing problem. As more researchers become involved in the study of parenting influences on childhood obesity, there appears to be a lack of agreement regarding the most important parenting constructs of interest, definitions of those constructs, and measurement of those cons...

  13. Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2013-01-01

    Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret eq for scan modes involving table translation and the midpoint dose D L (0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret eq was calculated from CTDI 100 and ε(CTDI 100 ) (CTDI 100 efficiency), and D L (0) was calculated from D-caret eq and the approach to equilibrium function H(L) =D L (0)/D eq , where D eq was the equilibrium dose. CTDI 100 may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI Vol using the central to peripheral CTDI 100 ratio (R 100 ). The authors have provided the required ε(CTDI 100 ) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R 100 was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D L (0) and D L (0)/D eq in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret eq and D L (0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI 100 ) and H(L) data in two previous papers. R 100 is presented for a majority of multidetector CT scanners currently on the market, and can be

  14. [Psychosocial risk factors in adolescent tobacco use: negative mood-states, peer group and parenting styles].

    Science.gov (United States)

    Julià Cano, Albert; Escapa Solanas, Sandra; Marí-Klose, Marga; Marí-Klose, Pau

    2012-01-01

    There are multiple factors that can affect the risk of tobacco use in adolescence. By analyzing these factors together we can disentangle the specific relevance of each of them in shaping teenagers' individual behavior. The goal of this research study is to deepen our understanding of the relationship between tobacco use in adolescence and socio-demographic and socio-emotional variables. We worked with a representative sample of 2,289 Catalan teenagers (aged 15-18) who responded to a questionnaire drawn up by the Families and Children Panel. Regression models were developed to assess the statistical associations of different mood states (sadness, nervousness and loneliness), peer-group characteristics and parenting styles, with tobacco use. The results indicate that addictive behavior is more likely when teenagers show negative mood states, controlling for socio-demographic variables and other risk factors. Among these additional factors, authoritative parenting styles reduce the risk of tobacco use, compared to authoritarian, permissive and neglectful parenting. Extensive tobacco use within the peer group is the risk factor most strongly associated with teenagers' individual behavior.

  15. Phantom dark ghost in Einstein-Cartan gravity

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yu-Chiao [National Taiwan University, Department of Physics, Taipei (China); National Taiwan University, LeCosPA, Taipei (China); Bouhmadi-Lopez, Mariam [University of the Basque Country UPV/EHU, Department of Theoretical Physics, P.O. Box 644, Bilbao (Spain); Basque Foundation for Science, IKERBASQUE, Bilbao (Spain); Chen, Pisin [National Taiwan University, Department of Physics, Taipei (China); National Taiwan University, LeCosPA, Taipei (China); National Taiwan University, Graduate Institute of Astrophysics, Taipei (China); SLAC National Accelerator Laboratory, Stanford University, Kavli Institute for Particle Astrophysics and Cosmology, Stanford, CA (United States)

    2017-05-15

    A class of dynamical dark energy models is constructed through an extended version of fermion fields corresponding to phantom dark ghost spinors, which are spin 1/2 with mass dimension 1. We find that if these spinors interact with torsion fields in a homogeneous and isotropic universe, then it does not imply any future dark energy singularity or any abrupt event, though the fermion has a negative kinetic energy. In fact, the equation of state of this dark energy model will asymptotically approach the value w = -1 from above without crossing the phantom divide and inducing therefore a de Sitter state. Consequently, we expect the model to be stable because no real phantom fields will be created. At late time, the torsion fields will vanish as the corresponding phantom dark ghost spinors dilute. As would be expected, intuitively, this result is unaffected by the presence of cold dark matter although the proof is not as straightforward as in general relativity. (orig.)

  16. Magnetoencephalography Phantom Comparison and Validation: Hospital Universiti Sains Malaysia (HUSM) Requisite.

    Science.gov (United States)

    Omar, Hazim; Ahmad, Alwani Liyan; Hayashi, Noburo; Idris, Zamzuri; Abdullah, Jafri Malin

    2015-12-01

    Magnetoencephalography (MEG) has been extensively used to measure small-scale neuronal brain activity. Although it is widely acknowledged as a sensitive tool for deciphering brain activity and source localisation, the accuracy of the MEG system must be critically evaluated. Typically, on-site calibration with the provided phantom (Local phantom) is used. However, this method is still questionable due to the uncertainty that may originate from the phantom itself. Ideally, the validation of MEG data measurements would require cross-site comparability. A simple method of phantom testing was used twice in addition to a measurement taken with a calibrated reference phantom (RefPhantom) obtained from Elekta Oy of Helsinki, Finland. The comparisons of two main aspects were made in terms of the dipole moment (Qpp) and the difference in the dipole distance from the origin (d) after the tests of statistically equal means and variance were confirmed. The result of Qpp measurements for the LocalPhantom and RefPhantom were 978 (SD24) nAm and 988 (SD32) nAm, respectively, and were still optimally within the accepted range of 900 to 1100 nAm. Moreover, the shifted d results for the LocalPhantom and RefPhantom were 1.84 mm (SD 0.53) and 2.14 mm (SD 0.78), respectively, and these values were below the maximum acceptance range of within 5.0 mm of the nominal dipole location. The Local phantom seems to outperform the reference phantom as indicated by the small standard error of the former (SE 0.094) compared with the latter (SE 0.138). The result indicated that HUSM MEG system was in excellent working condition in terms of the dipole magnitude and localisation measurements as these values passed the acceptance limits criteria of the phantom test.

  17. Evaluation of DQA for tomography using 3D volumetric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Uk [Dept. of Radiation Oncology, Catholic University of Incheon St. Mary' s Hospital, Incheon (Korea, Republic of); Kim, Jeong Koo [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2016-12-15

    The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with the prescribed dose; 1,200 cGy, 5 fractions. Gamma analysis (3%/3 mm, 2%/2 mm) of dose distribution was evaluated with gafchromic EBT2 film and ArcCHECK phantom. The average error of absolute dose was measured at 0.76±0.59% and 1.37±0.76% in cheese phantom and ArcCHECK phantom respectively. The average passing ratio for 3%/3 mm were 97.72±0.02% and 99.26±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. The average passing ratio for 2%/2 mm were 94.21±0.02% and 93.02±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. There was a more accurate dose distribution of 3D volume phantom than cheese phantom in patients DQA using tomotherapy. Therefor it should be evaluated simultaneously 3 dimensional dose evaluation on target and peripheral area in rotational radiotherapy such as tomotherapy.

  18. Performance of an automatic dose control system for CT. Anthropomorphic phantom studies

    Energy Technology Data Exchange (ETDEWEB)

    Gosch, D.; Stumpp, P.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Nagel, H.D. [Wissenschaft und Technik fuer die Radiologie, Dr. HD Nagel, Buchholz (Germany)

    2011-02-15

    Purpose: To assess the performance and to provide more detailed insight into characteristics and limitations of devices for automatic dose control (ADC) in CT. Materials and Methods: A comprehensive study on DoseRight 2.0, the ADC system provided by Philips for its Brilliance CT scanners, was conducted with assorted tests using an anthropomorphic phantom that allowed simulation of the operation of the system under almost realistic conditions. The scan protocol settings for the neck, chest and abdomen with pelvis were identical to those applied in the clinical routine. Results: Using the appropriate ADC functionalities, dose reductions equal 40 % for the neck, 20 % for the chest and 10 % for the abdomen with pelvis. Larger dose reductions can be expected for average patients, since their attenuating properties differ significantly from the anthropomorphic phantom. Adverse effects due to increased image noise were only moderate as a consequence of the 'adequate noise system' design and the complementary use of adaptive filtration. The results of specific tests also provided deeper insight into the operation of the ADC system that helps to identify the causes of suspected malfunctions and to prevent potential pitfalls. Conclusion: Tests with anthropomorphic phantoms allow verification of the characteristics of devices for ADC in CT under almost realistic conditions. However, differences in phantom shape and material composition require supplementary patient studies on representative patient groups. (orig.)

  19. The Family Startup Program: study protocol for a randomized controlled trial of a universal group-based parenting support program.

    Science.gov (United States)

    Trillingsgaard, Tea; Maimburg, Rikke Damkjær; Simonsen, Marianne

    2015-04-21

    Inadequate parenting is an important public health problem with possible severe and long-term consequences related to child development. We have solid theoretical and political arguments in favor of efforts enhancing the quality of the early family environment in the population at large. However, little is known about effect of universal approaches to parenting support during the transition to parenthood. This protocol describes an experimental evaluation of group based parenting support, the Family Startup Program (FSP), currently implemented large scale in Denmark. Participants will be approximately 2500 pregnant women and partners. Inclusion criteria are parental age above 18 and the mother expecting first child. Families are recruited when attending routine pregnancy scans provided as a part of the publicly available prenatal care program at Aarhus University Hospital, Skejby. Families are randomized within four geographically defined strata to one of two conditions a) participation in FSP or b) Treatment As Usual (TAU). FSP aims to prepare new families for their roles as parents and enhance parental access to informal sources of support, i.e. social network and community resources. The program consists of twelve group sessions, with nine families in each group, continuing from pregnancy until the child is 15 months old. TAU is the publicly available pre- and postnatal care available to families in both conditions. Analyses will employ survey data, administrative data from health visitors, and administrative register based data from Statistics Denmark. All data sources will be linked via the unique Danish Civil Registration Register (CPR) identifier. Data will be obtained at four time points, during pregnancy, when the child is nine months, 18 months and seven years. The primary study outcome is measured by the Parenting Sense of Competence scale (PSOC) J Clin Child Psychol 18:167-75, 1989. Other outcomes include parenting and couple relationship quality

  20. The Effectiveness of Group Assertiveness Training on Happiness in Rural Adolescent Females With Substance Abusing Parents.

    Science.gov (United States)

    Hojjat, Seyed Kaveh; Golmakani, Ebrahim; Norozi Khalili, Mina; Shakeri Chenarani, Maryam; Hamidi, Mahin; Akaberi, Arash; Rezaei Ardani, Amir

    2015-06-12

    Parental substance abuse confronts children with a variety of psychological, social, and behavioral problems. Children of substance abusing parents show higher levels of psychiatric disorders including anxiety and depression and exert lower levels of communication skills. Weak social skills in this group of adolescents put them at a higher risk for substance abuse. Many studies showed school based interventions such as life skill training can effective on future substance abusing in these high risk adolescences. The participants consisted of 57 middles schools girls, all living in rural areas and having both parents with substance dependency. The participants were randomly assigned to intervention (n=28) and control (n=29) groups. The data were collected before and six weeks after training in both group. The intervention group received eight sessions of group assertiveness training. Participants were compared in terms of changes in scores on the Oxford Happiness Questionnaire and the Gambrills-Richey Assertion Inventory. The total score for happiness change from 43.68 ±17.62 to 51.57 ±16.35 and assertiveness score changed from 110.33±16.05 to 90.40±12.84. There was a significant difference in pretest-posttest change in scores for intervention (7.89±4.13) and control (-2.51±2.64) groups; t (55) =2.15, p = 0.049. These results suggest that intervention really does have an effect on happiness and assertiveness. Determining the effectiveness of these school based interventions on other life aspects such as substance abuse calls for further study on these rural adolescent girls.

  1. Parental distress, parenting practices, and child adaptive outcomes following traumatic brain injury.

    Science.gov (United States)

    Micklewright, Jackie L; King, Tricia Z; O'Toole, Kathleen; Henrich, Chris; Floyd, Frank J

    2012-03-01

    Moderate and severe pediatric traumatic brain injuries (TBI) are associated with significant familial distress and child adaptive sequelae. Our aim was to examine the relationship between parental psychological distress, parenting practices (authoritarian, permissive, authoritative), and child adaptive functioning 12-36 months following TBI or orthopedic injury (OI). Injury type was hypothesized to moderate the relationship between parental distress and child adaptive functioning, demonstrating a significantly stronger relationship in the TBI relative to OI group. Authoritarian parenting practices were hypothesized to mediate relationship between parental distress and child adaptive functioning across groups. Groups (TBI n = 21, OI n = 23) did not differ significantly on age at injury, time since injury, sex, race, or SES. Parents completed the Brief Symptom Inventory, Parenting Practices Questionnaire, and Vineland-II. Moderation and mediation hypotheses were tested using hierarchical multiple regression and a bootstrapping approach, respectively. Results supported moderation and revealed that higher parental psychological distress was associated with lower child adaptive functioning in the TBI group only. Mediation results indicated that higher parental distress was associated with authoritarian parenting practices and lower adaptive functioning across groups. Results suggest that parenting practices are an important area of focus for studies attempting to elucidate the relationship between parent and child functioning following TBI.

  2. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yakun; Li Xiang; Paul Segars, W.; Samei, Ehsan [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States) and Department of Radiology, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University, Durham, North Carolina 27705 (United States) and Departments of Physics, Biomedical Engineering, and Electrical and Computer Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2012-06-15

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated

  3. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    International Nuclear Information System (INIS)

    Zhang Yakun; Li Xiang; Paul Segars, W.; Samei, Ehsan

    2012-01-01

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated

  4. Simultaneous calibration phantom commission and geometry calibration in cone beam CT

    Science.gov (United States)

    Xu, Yuan; Yang, Shuai; Ma, Jianhui; Li, Bin; Wu, Shuyu; Qi, Hongliang; Zhou, Linghong

    2017-09-01

    Geometry calibration is a vital step for describing the geometry of a cone beam computed tomography (CBCT) system and is a prerequisite for CBCT reconstruction. In current methods, calibration phantom commission and geometry calibration are divided into two independent tasks. Small errors in ball-bearing (BB) positioning in the phantom-making step will severely degrade the quality of phantom calibration. To solve this problem, we propose an integrated method to simultaneously realize geometry phantom commission and geometry calibration. Instead of assuming the accuracy of the geometry phantom, the integrated method considers BB centers in the phantom as an optimized parameter in the workflow. Specifically, an evaluation phantom and the corresponding evaluation contrast index are used to evaluate geometry artifacts for optimizing the BB coordinates in the geometry phantom. After utilizing particle swarm optimization, the CBCT geometry and BB coordinates in the geometry phantom are calibrated accurately and are then directly used for the next geometry calibration task in other CBCT systems. To evaluate the proposed method, both qualitative and quantitative studies were performed on simulated and realistic CBCT data. The spatial resolution of reconstructed images using dental CBCT can reach up to 15 line pair cm-1. The proposed method is also superior to the Wiesent method in experiments. This paper shows that the proposed method is attractive for simultaneous and accurate geometry phantom commission and geometry calibration.

  5. Parent training support for intellectually disabled parents.

    Science.gov (United States)

    Coren, Esther; Hutchfield, Jemeela; Thomae, Manuela; Gustafsson, Carina

    2010-06-16

    Intellectual disability may impact on an individual's capacity to parent a child effectively. Research suggests that the number of intellectually disabled people with children is increasing. Children of parents with intellectual disabilities may be at increased risk of neglectful care which could lead to health, developmental and behavioural problems, or increased risk of intellectual disability.However, there is some indication that some parents with intellectual disabilities are able to provide adequate child care if they are given appropriate training and support to do so. To assess the effectiveness of parent training interventions to support the parenting of parents with intellectual disabilities We searched the following databases: Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), MEDLINE, EMBASE, CINAHL, PsycINFO, ASSIA, Sociological Abstracts, Dissertation Abstracts International, MetaRegister of Controlled Trials, and ZETOC. Randomised controlled trials comparing parent training interventions for parents with intellectual disabilities with usual care or with a control group. Outcomes of interest were: the attainment of parenting skills specific to the intervention, safe home practices and the understanding of child health. Two review authors independently assessed risk of bias and undertook data extraction. Three trials met the inclusion criteria for this review but no meta-analysis was possible. One study reported improved maternal-child interaction following group parent training compared with the control group. The second study reported some improvements in parents knowledge of life threatening emergencies, ability to recognise dangers and identify precautions and smaller improvements in their ability to implement precautions, use medicines safely and recognise child illness and symptoms. The third study reported improvement in child care and safety skills following the intervention. There is some risk of bias in the

  6. [Mini-KiSS--a multimodal group therapy intervention for parents of young children with sleep disorders: a pilot study].

    Science.gov (United States)

    Schlarb, Angelika Anita; Brandhorst, Isabel; Hautzinger, Martin

    2011-05-01

    Sleep disorders in early childhood tend to be chronic and almost always a burden for the parents. This study developed and evaluated a multimodal parent training program for children 0.5 to 4 years of age suffering from sleep disorders (Mini-KiSS). We hypothesized that there would be specific improvements following the structured group training (reduction of sleep problems, improvement of parental well-being). The pilot study consisted of a pre-post test design without control group. Participants were n = 17 parents of children 0.5 to 4 years of age with sleep disorders determined according to the ICSD-II. Each of the six sessions was evaluated, and changes were assessed by sleep diary and CBCL. Behavioral and emotional problems of the child were assessed by CBCL, parental well-being, and SCL-90-R. The results showed high acceptance of Mini-KiSS and satisfactory feasibility. Children showed significant improvements of the sleep disturbances such as nightly awakenings as well as sleeping in parents' bed. Furthermore, improvements were found for children's emotional and behavioral problems and for parental well-being, in particular for the depression scale of the mother. This pilot study shows a high acceptance and good feasibility of the multimodal short-time parent-training program Mini-KiSS. Sleep problems were significantly reduced.

  7. Phantom energy accretion onto black holes in a cyclic universe

    International Nuclear Information System (INIS)

    Sun Chengyi

    2008-01-01

    Black holes pose a serious problem in cyclic or oscillating cosmology. It is speculated that, in the cyclic universe with phantom turnarounds, black holes will be torn apart by phantom energy prior to turnaround before they can create any problems. In this paper, using the mechanism of phantom accretion onto black holes, we find that black holes do not disappear before phantom turnaround. But the remanent black holes will not cause any problems due to Hawking evaporation.

  8. Effect of park prescriptions with and without group visits to parks on stress reduction in low-income parents: SHINE randomized trial.

    Science.gov (United States)

    Razani, Nooshin; Morshed, Saam; Kohn, Michael A; Wells, Nancy M; Thompson, Doug; Alqassari, Maoya; Agodi, Amaka; Rutherford, George W

    2018-01-01

    Exposure to nature may reduce stress in low-income parents. This prospective randomized trial compares the effect of a physician's counseling about nature with or without facilitated group outings on stress and other outcomes among low-income parents. Parents of patients aged 4-18 years at a clinic serving low-income families were randomized to a supported park prescription versus independent park prescription in a 2:1 ratio. Parents in both groups received physician counseling about nature, maps of local parks, a journal, and pedometer. The supported group received additional phone and text reminders to attend three weekly family nature outings with free transportation, food, and programming. Outcomes measured in parents at baseline, one month and three months post-enrollment included: stress (using the 40-point Perceived Stress Scale [PSS10]); park visits per week (self-report and journaling); loneliness (modified UCLA-Loneliness Scale); physical activity (self-report, journaling, pedometry); physiologic stress (salivary cortisol); and nature affinity (validated scale). We enrolled 78 parents, 50 in the supported and 28 in the independent group. One-month follow-up was available for 60 (77%) participants and three-month follow up for 65 (83%). Overall stress decreased by 1.71 points (95% CI, -3.15, -0.26). The improvement in stress did not differ significantly by group assignment, although the independent group had more park visits per week (mean difference 1.75; 95% CI [0.46, 3.04], p = 0.0085). In multivariable analysis, each unit increase in park visits per week was associated with a significant and incremental decrease in stress (change in PSS10-0.53; 95% CI [-0.89, -0.16]; p = 0.005) at three months. While we were unable to demonstrate the additional benefit of group park visits, we observed an overall decrease in parental stress both overall and as a function of numbers of park visits per week. Paradoxically the park prescription without group park visits

  9. Effect of park prescriptions with and without group visits to parks on stress reduction in low-income parents: SHINE randomized trial.

    Directory of Open Access Journals (Sweden)

    Nooshin Razani

    Full Text Available Exposure to nature may reduce stress in low-income parents. This prospective randomized trial compares the effect of a physician's counseling about nature with or without facilitated group outings on stress and other outcomes among low-income parents.Parents of patients aged 4-18 years at a clinic serving low-income families were randomized to a supported park prescription versus independent park prescription in a 2:1 ratio. Parents in both groups received physician counseling about nature, maps of local parks, a journal, and pedometer. The supported group received additional phone and text reminders to attend three weekly family nature outings with free transportation, food, and programming. Outcomes measured in parents at baseline, one month and three months post-enrollment included: stress (using the 40-point Perceived Stress Scale [PSS10]; park visits per week (self-report and journaling; loneliness (modified UCLA-Loneliness Scale; physical activity (self-report, journaling, pedometry; physiologic stress (salivary cortisol; and nature affinity (validated scale.We enrolled 78 parents, 50 in the supported and 28 in the independent group. One-month follow-up was available for 60 (77% participants and three-month follow up for 65 (83%. Overall stress decreased by 1.71 points (95% CI, -3.15, -0.26. The improvement in stress did not differ significantly by group assignment, although the independent group had more park visits per week (mean difference 1.75; 95% CI [0.46, 3.04], p = 0.0085. In multivariable analysis, each unit increase in park visits per week was associated with a significant and incremental decrease in stress (change in PSS10-0.53; 95% CI [-0.89, -0.16]; p = 0.005 at three months.While we were unable to demonstrate the additional benefit of group park visits, we observed an overall decrease in parental stress both overall and as a function of numbers of park visits per week. Paradoxically the park prescription without group park

  10. Construction of average adult Japanese voxel phantoms for dose assessment

    International Nuclear Information System (INIS)

    Sato, Kaoru; Takahashi, Fumiaki; Satoh, Daiki; Endo, Akira

    2011-12-01

    The International Commission on Radiological Protection (ICRP) adopted the adult reference voxel phantoms based on the physiological and anatomical reference data of Caucasian on October, 2007. The organs and tissues of these phantoms were segmented on the basis of ICRP Publication 103. In future, the dose coefficients for internal dose and dose conversion coefficients for external dose calculated using the adult reference voxel phantoms will be widely used for the radiation protection fields. On the other hand, the body sizes and organ masses of adult Japanese are generally smaller than those of adult Caucasian. In addition, there are some cases that the anatomical characteristics such as body sizes, organ masses and postures of subjects influence the organ doses in dose assessment for medical treatments and radiation accident. Therefore, it was needed to use human phantoms with average anatomical characteristics of Japanese. The authors constructed the averaged adult Japanese male and female voxel phantoms by modifying the previously developed high-resolution adult male (JM) and female (JF) voxel phantoms. It has been modified in the following three aspects: (1) The heights and weights were agreed with the Japanese averages; (2) The masses of organs and tissues were adjusted to the Japanese averages within 10%; (3) The organs and tissues, which were newly added for evaluation of the effective dose in ICRP Publication 103, were modeled. In this study, the organ masses, distances between organs, specific absorbed fractions (SAFs) and dose conversion coefficients of these phantoms were compared with those evaluated using the ICRP adult reference voxel phantoms. This report provides valuable information on the anatomical and dosimetric characteristics of the averaged adult Japanese male and female voxel phantoms developed as reference phantoms of adult Japanese. (author)

  11. Phantoms and computational models in therapy, diagnosis and protection

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The development of realistic body phantoms and computational models is strongly dependent on the availability of comprehensive human anatomical data. This information is often missing, incomplete or not easily available. Therefore, emphasis is given in the Report to organ and body masses and geometries. The influence of age, sex and ethnic origins in human anatomy is considered. Suggestions are given on how suitable anatomical data can be either extracted from published information or obtained from measurements on the local population. Existing types of phantoms and computational models used with photons, electrons, protons and neutrons are reviewed in this Report. Specifications of those considered important to the maintenance and development of reliable radiation dosimetry and measurement are given. The information provided includes a description of the phantom or model, together with diagrams or photographs and physical dimensions. The tissues within body sections are identified and the tissue substitutes used or recommended are listed. The uses of the phantom or model in radiation dosimetry and measurement are outlined. The Report deals predominantly with phantom and computational models representing the human anatomy, with a short Section devoted to animal phantoms in radiobiology

  12. Examining the Effectiveness of Group Positive Parenting Training on Increasing Hope and Life Satisfaction in Mothers of Children with Autism

    Directory of Open Access Journals (Sweden)

    Seyed Omid Sotoudeh Navroodi

    2018-04-01

    Full Text Available Objective: Parents of children with autism spectrum disorders are exposed to mental distress because of having a disabled child more than parents with children with other psychological disorders, and their children's disorder has a negative effect on their hope and life satisfaction. The present study aimed to examining the effectiveness of group positive parenting training on increasing hope and life satisfaction in mothers of children with autism.Method: This was a quasi-experimental study with pretest, posttest, and control and experimental groups. Mothers with autistic children (6-15 years in Rasht consisted the statistical population of the study. All the children had a medical record and autism diagnosis based on DSM-IV-TR by a psychiatrist. Hope Questionnaires by Snyder and Life Satisfaction Questionnaire by Diener were implemented. Participants of the experimental group received positive parenting training for 8 sessions, and participants of the control group were put in the state of waiting. Descriptive statistics (mean, standard deviation, frequency, and percentage and inferential statistics (univariate and multivariate covariance analysis were used for data analysis.Results: In this study, 27 mothers of children with autism were examined. The mean and standard deviation of the age of mothers in the experimental group was 36.14± 2.47 years and it was 37± 3.62 years for mothers in the control group. The results of univariate covariance analysis revealed a significant difference between the scores of pretest and posttest of the experimental and control groups in life satisfaction (Sum of square = 16.558, F = 13.534, DF = 1, P = 0.002, 〖=ƞ〗^2 = 0.361.Conclusion: The results of this study showed that using group positive parenting training can have a positive effect on dimensions of hope and life satisfaction in mothers of children with autism spectrum disorder.

  13. Benchmark calculations with simple phantom for neutron dosimetry (2)

    International Nuclear Information System (INIS)

    Yukio, Sakamoto; Shuichi, Tsuda; Tatsuhiko, Sato; Nobuaki, Yoshizawa; Hideo, Hirayama

    2004-01-01

    Benchmark calculations for high-energy neutron dosimetry were undertaken after SATIF-5. Energy deposition in a cylindrical phantom with 100 cm radius and 30 cm depth was calculated for the irradiation of neutrons from 100 MeV to 10 GeV. Using the ICRU four-element loft tissue phantom and four single-element (hydrogen, carbon, nitrogen and oxygen) phantoms, the depth distributions of deposition energy and those total at the central region of phantoms within l cm radius and at the whole region of phantoms within 100 cm radius were calculated. The calculated results of FLUKA, MCNPX, MARS, HETC-3STEP and NMTC/JAM codes were compared. It was found that FLUKA, MARS and NMTC/JAM showed almost the same results. For the high-energy neutron incident, the MCNP-X results showed the largest ones in the total deposition energy and the HETC-3STEP results show'ed smallest ones. (author)

  14. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  15. Design and development of spine phantom to verify dosimetric accuracy of stereotactic body radiation therapy using 3D prnter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seu Ran; Lee, Min Young; Kim, Min Joo; Park, So Hyun; Song Ji Hye; Suh, Tae Suk [Dept. of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Sohn, Jason W. [Dept. of Radiation Oncology, College of Medicine, Case Western Reserve University, Cleveland (United States)

    2015-10-15

    The purpose of this study is to verify dosimetric accuracy of delivered dose in spine SBRT as highly precise radiotherapy depending on cancer position using dedicated spine phantom based on 3D printer. Radiation therapy oncology group (RTOG) 0631 suggest different planning method in spine stereotactic body radiation therapy (SBRT) according to location of cancer owing to its distinct shape. The developed phantom especially using DLP method can be utilized as spine SBRT dosimetry research. Our study was able to confirm that the phantom was indeed similar with HU value of human spine as well as its shape.

  16. Deformable and durable phantoms with controlled density of scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Bisaillon, Charles-Etienne; Lamouche, Guy; Dufour, Marc; Monchalin, Jean-Pierre [Industrial Materials Institute, National Research Council Canada, 75 de Mortagne, Boucherville, Quebec J4B 6Y4 (Canada); Maciejko, Romain [Optoelectronics Laboratory, Engineering Physics, Ecole Polytechnique de Montreal, PO Box 6079, Station ' Centre-ville' Montreal, Quebec H3C 3A7 (Canada)], E-mail: charles-etienne.bisaillon@cnrc-nrc.gc.ca, E-mail: guy.lamouche@cnrc-nrc.gc.ca, E-mail: marc.dufour@cnrc-nrc.gc.ca, E-mail: jean-pierre.monchalin@cnrc-nrc.gc.ca, E-mail: romain.maciejko@polytml.ca

    2008-07-07

    We have developed deformable and durable optical tissue phantoms with a simple and well-defined microstructure including a novel combination of scatterers and a matrix material. These were developed for speckle and elastography investigations in optical coherence tomography, but should prove useful in many other fields. We present in detail the fabrication process which involves embedding silica microspheres in a silicone matrix. We also characterize the resulting phantoms with scanning electron microscopy and optical measurements. To our knowledge, no such phantoms were proposed in the literature before. Our technique has a wide range of applicability and could also be adapted to fabricate phantoms with various optical and mechanical properties. (note)

  17. A Novel Simple Phantom for Verifying the Dose of Radiation Therapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2015-01-01

    Full Text Available A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent dosimeters (TLDs were used as postal dosimeters, and mailable phantoms were produced for use in postal audits. Correction factors are important for converting TLD readout values from phantoms into the absorbed dose in water. The phantom scatter correction factor was used to quantify the difference in the scattered dose between a solid water phantom and homemade phantoms; its value ranged from 1.084 to 1.031. The energy-dependence correction factor was used to compare the TLD readout of the unit dose irradiated by audit beam energies with 60Co in the solid water phantom; its value was 0.99 to 1.01. The setup-condition factor was used to correct for differences in dose-output calibration conditions. Clinical tests of the device calibrating the dose output revealed that the dose deviation was within 3%. Therefore, our homemade phantoms and dosimetric system can be applied for accurately verifying the doses applied in radiation-therapy institutions.

  18. A randomised group comparison controlled trial of 'preschoolers with autism': a parent education and skills training intervention for young children with autistic disorder.

    Science.gov (United States)

    Tonge, Bruce; Brereton, Avril; Kiomall, Melissa; Mackinnon, Andrew; Rinehart, Nicole J

    2014-02-01

    To determine the effect of parent education on adaptive behaviour, autism symptoms and cognitive/language skills of young children with autistic disorder. A randomised group comparison design involving a parent education and counselling intervention and a parent education and behaviour management intervention to control for parent skills training and a control sample. Two rural and two metropolitan regions were randomly allocated to intervention groups (n = 70) or control (n = 35). Parents from autism assessment services in the intervention regions were randomly allocated to parent education and behaviour management (n = 35) or parent education and counselling (n = 35). Parent education and behaviour management resulted in significant improvement in adaptive behaviour and autism symptoms at 6 months follow-up for children with greater delays in adaptive behaviour. Parent education and behaviour management was superior to parent education and counselling. We conclude that a 20-week parent education programme including skills training for parents of young children with autistic disorder provides significant improvements in child adaptive behaviour and symptoms of autism for low-functioning children.

  19. Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging

    Science.gov (United States)

    Kostiukhina, Natalia; Georg, Dietmar; Rollet, Sofia; Kuess, Peter; Sipaj, Andrej; Andrzejewski, Piotr; Furtado, Hugo; Rausch, Ivo; Lechner, Wolfgang; Steiner, Elisabeth; Kertész, Hunor; Knäusl, Barbara

    2017-10-01

    A novel breathing phantom was designed for being used in conventional and ion-beam radiotherapy as well as for medical imaging. Accurate dose delivery and patient safety are aimed to be verified for four-dimensional (4D) treatment techniques compensating for breathing-induced tumor motion. The phantom includes anthropomorphic components representing an average human thorax. It consists of real tissue equivalent materials to fulfill the requirements for dosimetric experiments and imaging purposes. The different parts of the torso (lungs, chest wall, and ribs) and the tumor can move independently. Simple regular movements, as well as more advanced patient-specific breathing cycles are feasible while a reproducible setup can be guaranteed. The phantom provides the flexibility to use different types of dosimetric devices and was designed in a way that it is robust, transportable and easy to handle. Tolerance levels and the reliability of the phantom setup were determined in combination with tests on motion accuracy and reproducibility by using infrared optical tracking technology. Different imaging was performed including positron emission tomography imaging, 4D computed tomography as well as real-time in-room imaging. The initial dosimetric benchmarking studies were performed in a photon beam where dose parameters are predictable and the dosimetric procedures well established.

  20. Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging.

    Science.gov (United States)

    Kostiukhina, Natalia; Georg, Dietmar; Rollet, Sofia; Kuess, Peter; Sipaj, Andrej; Andrzejewski, Piotr; Furtado, Hugo; Rausch, Ivo; Lechner, Wolfgang; Steiner, Elisabeth; Kertész, Hunor; Knäusl, Barbara

    2017-10-04

    A novel breathing phantom was designed for being used in conventional and ion-beam radiotherapy as well as for medical imaging. Accurate dose delivery and patient safety are aimed to be verified for four-dimensional (4D) treatment techniques compensating for breathing-induced tumor motion. The phantom includes anthropomorphic components representing an average human thorax. It consists of real tissue equivalent materials to fulfill the requirements for dosimetric experiments and imaging purposes. The different parts of the torso (lungs, chest wall, and ribs) and the tumor can move independently. Simple regular movements, as well as more advanced patient-specific breathing cycles are feasible while a reproducible setup can be guaranteed. The phantom provides the flexibility to use different types of dosimetric devices and was designed in a way that it is robust, transportable and easy to handle. Tolerance levels and the reliability of the phantom setup were determined in combination with tests on motion accuracy and reproducibility by using infrared optical tracking technology. Different imaging was performed including positron emission tomography imaging, 4D computed tomography as well as real-time in-room imaging. The initial dosimetric benchmarking studies were performed in a photon beam where dose parameters are predictable and the dosimetric procedures well established.

  1. Voxel anthropomorphic phantoms: review of models used for ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Lemosquet, A.; Carlan, L. de; Clairand, I.

    2003-01-01

    Computational anthropomorphic phantoms have been used since the 1970's for dosimetric calculations. Realistic geometries are required for this operation, resulting in the development of ever more accurate phantoms. Voxel phantoms, consisting of a set of small-volume elements, appeared towards the end of the 1980's, and significantly improved on the original mathematical models. Voxel phantoms are models of the human body, obtained using computed tomography (CT) or magnetic resonance images (MRI). These phantoms are an extremely accurate representation of the human anatomy. This article provides a review of the literature available on the development of these phantoms and their applications in ionising radiation dosimetry. The bibliographical study has shown that there is a wide range of phantoms, covering various characteristics of the general population in terms of sex, age or morphology, and that they are used in applications relating to all aspects of ionising radiation. (author)

  2. Factors that influence vaccination decision-making by parents who visit an anthroposophical child welfare center: a focus group study

    NARCIS (Netherlands)

    Harmsen, I.A.; Ruiter, R.A.C.; Paulussen, T.G.W.M.; Mollema, L.; Kok, G.; de Melker, H.E.R.

    2012-01-01

    In recent years, parents have become more disparaging towards childhood vaccination. One group that is critical about the National Immunization Program (NIP) and participates less comprises parents with an anthroposophical worldview. Despite the fact that various studies have identified

  3. Hubungan Phantom Vibration Syndrome Terhadap Sleep Disorder dan Kondisi Stress

    Directory of Open Access Journals (Sweden)

    Ajeng Yeni Setianingrum

    2017-10-01

    Full Text Available Phantom vibration syndrome is a condition where a person would feel the sensation of vibration of a cell phone as if there were incoming notification but the fact is not. This research investigated the relationship between phantom vibration syndromes, sleep disorder and stress condition. Questionnaires were distributed to 120 participants with age range 18 to 23 years old. Data of participants showed that all of participants using a smart mobile phone and 24% of them have more than one cell phone. Time usage of cell phone is at least 1 hour. 23% of participants using a cell phone for social media activity, followed by 21% related to entertainment (music, video and games. The results showed a positive relationship between phantom vibration syndrome, sleep disorder and stress condition. Insomnia contributed a greater influence on stress condition. However, the phantom vibration syndrome is more directly affecting the sleep apnea compared to insomnia and stress condition. Therefore, the phantom vibration syndrome more affects stress condition indirectly, through sleep disorder (sleep apnea and insomnia. Consequently, phantom vibration syndrome has a strong relationship with stress condition at the time of the phantom vibration syndrome can cause sleep disorder.

  4. Estimation of computed tomography dose in various phantom shapes and compositions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Lae [Dept. of Radiological Science, Yonsei University, Seoul (Korea, Republic of)

    2017-03-15

    The purpose of this study was to investigate CTDI (computed tomography dose index at center) for various phantom shapes, sizes, and compositions by using GATE (geant4 application for tomographic emission) simulations. GATE simulations were performed for various phantom shapes (cylinder, elliptical, and hexagonal prism PMMA phantoms) and phantom compositions (water, PMMA, polyethylene, polyoxymethylene) with various diameters (1-50 cm) at various kVp and mAs levels. The CTDI100center values of cylinder, elliptical, and hexagonal prism phantom at 120 kVp, 200 mAs resulted in 11.1, 13.4, and 12.2 mGy, respectively. The volume is the same, but CTDI{sub 100center} values are different depending on the type of phantom. The water, PMMA, and polyoxymethylene phantom CTDI{sub 100center} values were relatively low as the material density increased. However, in the case of Polyethylene, the CTDI{sub 100center} value was higher than that of PMMA at diameters exceeding 15 cm (CTDI{sub 100center} : 35.0 mGy). And a diameter greater than 30 cm (CTDI{sub 100center} : 17.7 mGy) showed more CTDI{sub 100center} than Water. We have used limited phantoms to evaluate CT doses. In this study, CTDI{sub 100center} values were estimated and simulated by GATE simulation according to the material and shape of the phantom. CT dosimetry can be estimated more accurately by using various materials and phantom shapes close to human body.

  5. Radiological response and dosimetry in physical phantom of head and neck for 3D conformational radiotherapy; Resposta radiologica e dosimetria em phantom fisico de cabeca e pescoco para radioterapia conformacional 3D

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Larissa

    2013-07-01

    Phantoms are tools for simulation of organs and tissues of the human body in radiology and radiotherapy. This thesis describes the development, validation and, most importantly, the use of a physical head and neck phantom in radiology and radiotherapy, with the purpose of evaluating dose distribution using Gafchromic EBT2 film in 15 MV 3D conformal radiotherapy. The work was divided in two stages, (1) development of new equivalent tissues and improvement of the physical phantom, and (2) use of the physical phantom in experimental dosimetry studies. In phase (1) parameters such as mass density, chemical composition of tissues, anatomical and biometric measurements were considered, as well as aspects of imaging by computed tomography (CT) and radiological response representation in Hounsfield Units (HU), which were compared with human data. Radiological experiments of in-phantom simulated brain pathologies were also conducted. All those results matched human-sourced data, therefore the physical phantom is a suitable simulator that may be used to enhance radiological protocols and education in medical imaging. The main objective in phase (2) was to evaluate the spatial dose distribution in a brain tumor simulator inserted inside the head and neck phantom developed by the Ionizing Radiation Research Group (NRI), exposed to 15 MV 3D conformal radiotherapy, for internal dose assessment. Radiation planning was based on CT images of the physical phantom with a brain tumor simulator made with equivalent material. The treatment planning system (TPS), CAT3D software, used CT images and prescribed a dose of 200 cGy, distributed in three fields of radiation, in a T-shaped pattern. The TPS covered the planning treatment volume (PTV) with 97% of the prescribed dose. A solid water phantom and radiochromic Gafchromic EBT2 film were used for calibration procedures, generating a dose response curve as a function of optical density (OD). After calibration and irradiation, the film

  6. A solid tissue phantom for photon migration studies

    International Nuclear Information System (INIS)

    Cubeddu, Rinaldo; Pifferi, Antonio; Taroni, Paola; Torricelli, Alessandro; Valentini, Gianluca

    1997-01-01

    A solid tissue phantom made of agar, Intralipid and black ink is described and characterized. The preparation procedure is fast and easily implemented with standard laboratory equipment. An instrumentation for time-resolved transmittance measurements was used to determine the optical properties of the phantom. The absorption and the reduced scattering coefficients are linear with the ink and Intralipid concentrations, respectively. A systematic decrease of the reduced scattering coefficient dependent on the agar content is observed, but can easily be managed. The phantom is highly homogeneous and shows good repeatability among different preparations. Moreover, agar inclusions can be easily embedded in either solid or liquid matrixes, and no artefacts are caused by the solid - solid or solid - liquid interfaces. This allows one to produce reliable and realistic inhomogeneous phantoms with known optical properties, particularly interesting for studies on optical imaging through turbid media. (author)

  7. Phantom inflation and the 'Big Trip'

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Diaz, Pedro F. [Colina de los Chopos, Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)]. E-mail: p.gonzalezdiaz@imaff.cfmac.csic.es; Jimenez-Madrid, Jose A. [Colina de los Chopos, Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)

    2004-08-19

    Primordial inflation is regarded to be driven by a phantom field which is here implemented as a scalar field satisfying an equation of state p={omega}{rho}, with {omega}-1. Being even aggravated by the weird properties of phantom energy, this will pose a serious problem with the exit from the inflationary phase. We argue, however, in favor of the speculation that a smooth exit from the phantom inflationary phase can still be tentatively recovered by considering a multiverse scenario where the primordial phantom universe would travel in time toward a future universe filled with usual radiation, before reaching the big rip. We call this transition the 'Big Trip' and assume it to take place with the help of some form of anthropic principle which chooses our current universe as being the final destination of the time transition.

  8. Fabrication of subcutaneous veins phantom for vessel visualization system

    Science.gov (United States)

    Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio

    2013-09-01

    The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.

  9. Development of thyroid anthropomorphic phantoms for use in nuclear medicine

    Science.gov (United States)

    Cerqueira, R. A. D.; Maia, A. F.

    2014-02-01

    The objective of this study was to develop thyroid anthropomorphic phantoms to be used in control tests of medical images in scintillation cameras. The main difference among the phantoms was the neck shape: in the first, called OSCT, it was geometrically shaped, while in the second, called OSAP, it was anthropomorphically shaped. In both phantoms, thyroid gland prototypes, which were made of acrylic and anthropomorphically shaped, were constructed to allow the simulation of a healthy thyroid and of thyroids with hyperthyroidism and hypothyroidism. Images of these thyroid anthropomorphic phantoms were obtained using iodine 131 with an activity of 8.695 MBq. The iodine 131 was chosen because it is widely used in studies of thyroid scintigraphy. The images obtained proved the effectiveness of the phantoms to simulate normal or abnormal thyroids function. These phantoms can be used in medical imaging quality control programs and, also in the training of professionals involved in the analysis of images in nuclear medicine centers.

  10. Construction of a preclinical multimodality phantom using tissue-mimicking materials for quality assurance in tumor size measurement.

    Science.gov (United States)

    Lee, Yongsook C; Fullerton, Gary D; Goins, Beth A

    2013-07-29

    World Health Organization (WHO) and the Response Evaluation Criteria in Solid Tumors (RECIST) working groups advocated standardized criteria for radiologic assessment of solid tumors in response to anti-tumor drug therapy in the 1980s and 1990s, respectively. WHO criteria measure solid tumors in two-dimensions, whereas RECIST measurements use only one-dimension which is considered to be more reproducible (1, 2, 3,4,5). These criteria have been widely used as the only imaging biomarker approved by the United States Food and Drug Administration (FDA) (6). In order to measure tumor response to anti-tumor drugs on images with accuracy, therefore, a robust quality assurance (QA) procedures and corresponding QA phantom are needed. To address this need, the authors constructed a preclinical multimodality (for ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI)) phantom using tissue-mimicking (TM) materials based on the limited number of target lesions required by RECIST by revising a Gammex US commercial phantom (7). The Appendix in Lee et al. demonstrates the procedures of phantom fabrication (7). In this article, all protocols are introduced in a step-by-step fashion beginning with procedures for preparing the silicone molds for casting tumor-simulating test objects in the phantom, followed by preparation of TM materials for multimodality imaging, and finally construction of the preclinical multimodality QA phantom. The primary purpose of this paper is to provide the protocols to allow anyone interested in independently constructing a phantom for their own projects. QA procedures for tumor size measurement, and RECIST, WHO and volume measurement results of test objects made at multiple institutions using this QA phantom are shown in detail in Lee et al. (8).

  11. Effectiveness of a parental training programme in enhancing the parent-child relationship and reducing harsh parenting practices and parental stress in preparing children for their transition to primary school: a randomised controlled trial.

    Science.gov (United States)

    Li, Ho Cheung William; Chan, Sophia S C; Mak, Yim Wah; Lam, Tai Hing

    2013-11-16

    Entering primary school is an important childhood milestone, marking the beginning of a child's formal education. Yet the change creates a time of vulnerability for the child, the parents and the parent-child relationship. Failure to adjust to the transition may place the family in a psychologically devastating position. The aims of this study were to test the effectiveness of a parental training programme in enhancing the parent-child relationship and decreasing parental stress by reducing harsh parenting in preparing children for the transition to primary school. A randomised controlled trial incorporating a two-group pre-test and repeated post-test was conducted in one of the largest public housing estates in Hong Kong. A total of 142 parents were recruited, with 72 parents randomly assigned to the experimental group and 70 to the control group. Harsh parenting practices, parent-child relationships and parental stress were assessed. In comparison to parents in the control group, those in the experimental group engaged in less harsh parenting practices and reported better parent-child relationships. However, parental stress scores did not differ significantly between the two groups. This study addressed a gap in the literature by examining the effectiveness of the training programme for enhancing parent-child relationship and decreasing parental stress at the time of a child's transition to primary school. The findings from this study provide empirical evidence of the effectiveness of the parental training programme and highlight the significance of parenting in promoting a smooth transition for children from kindergarten to primary 1. ClinicalTrials.gov: NCT01845948.

  12. Sexual risk attitudes and intentions of youth aged 12-14 years: survey comparisons of parent-teen prevention and control groups.

    Science.gov (United States)

    Lederman, Regina P; Chan, Wenyaw; Roberts-Gray, Cynthia

    2004-01-01

    In this study, the authors compared differences in sexual risk attitudes and intentions for three groups of youth (experimental program, n = 90; attention control, n = 80; and nonparticipant control, n = 634) aged 12-14 years. Two student groups participated with their parents in programs focused on strengthening family interaction and prevention of sexual risks, HIV, and adolescent pregnancy. Surveys assessed students' attitudes and intentions regarding early sexual and other health-risk behaviors, family interactions, and perceived parental disapproval of risk behaviors. The authors used general linear modeling to compare results. The experimental prevention program differentiated the total scores of the 3 groups (p < .05). A similar result was obtained for student intentions to avoid sex (p < .01). Pairwise comparisons showed the experimental program group scored higher than the nonparticipant group on total scores (p < .01) and on students' intention to avoid sex (p < .01). The results suggest this novel educational program involving both parents and students offers a promising approach to HIV and teen pregnancy prevention.

  13. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  14. Simplified spinal cord phantom for evaluation of SQUID magnetospinography

    International Nuclear Information System (INIS)

    Adachi, Y; Oyama, D; Uehara, G; Somchai, N; Kawabata, S

    2014-01-01

    Spinal cord functional imaging by magnetospinography (MSG) is a noninvasive diagnostic method for spinal cord diseases. However, the accuracy and spatial resolution of lesion localization by MSG have barely been evaluated in detail so far. We developed a simplified spinal cord phantom for MSG evaluation. The spinal cord phantom is composed of a cylindrical vessel filled with saline water, which acts as a model of a neck. A set of modeled vertebrae is arranged in the cylindrical vessel, which has a neural current model made from catheter electrodes. The neural current model emulates the current distribution around the activated site along the axon of the spinal cord nerve. Our MSG system was used to observe the magnetic field from the phantom; a quadrupole-like pattern of the magnetic field distribution, which is a typical distribution pattern for spinal cord magnetic fields, was successfully reproduced by the phantom. Hence, the developed spinal cord phantom can be used to evaluate MSG source analysis methods.

  15. OSL Based Anthropomorphic Phantom and Real-Time Organ Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    David E. Hintenlang, Ph.D

    2009-02-10

    The overall objective of this project was the development of a dosimetry system that provides the direct measurement of organ does in real-time with a sensitivity that makes it an effective tool for applications in a wide variety of health physics applications. The system included the development of a real-time readout system for fiber optic coupled (FOC) dosimeters that is integrated with a state-of-art anthropomorphic phantom to provide instantaneous measures of organ doses throughout the phantom. The small size of the FOC detectors and optical fibers allow the sensitive volume of the detector to be located at organ centroids (or multiple locations distributed through the organ) within a tissue equivalent, anthropomorphic phantom without perturbing the tissue equivalent features of the phantom. The developed phantom/dosimetry system can be used in any environment where personnel may be exposed to gamma or x-ray radiations to provide the most accurate determinations of organ and effective doses possible to date.

  16. OSL Based Anthropomorphic Phantom and Real-Time Organ Dosimetry

    International Nuclear Information System (INIS)

    Hintenlang, David E.

    2009-01-01

    The overall objective of this project was the development of a dosimetry system that provides the direct measurement of organ doses in real-time with a sensitivity that makes it an effective tool for applications in a wide variety of health physics applications. The system included the development of a real-time readout system for fiber optic coupled (FOC) dosimeters that is integrated with a state-of-art anthropomorphic phantom to provide instantaneous measures of organ doses throughout the phantom. The small size of the FOC detectors and optical fibers allow the sensitive volume of the detector to be located at organ centroids (or multiple locations distributed through the organ) within a tissue equivalent, anthropomorphic phantom without perturbing the tissue equivalent features of the phantom. The developed phantom/dosimetry system can be used in any environment where personnel may be exposed to gamma or x-ray radiations to provide the most accurate determinations of organ and effective doses possible to date

  17. Introduction of a stack-phantom for PET

    International Nuclear Information System (INIS)

    Jonsson, C.; Schnell, P.O.; Jacobsson, H.; Engelin, L.; Danielsson, A.M.; Johansson, L.; Larsson, S.A.; Pagani, M.; Stone-Elander, S.

    2002-01-01

    Aim: We have previously developed a new flexible phantom system for SPECT, i.e. 'the stack phantom' (Eur. J. Nucl. Med. 27, No.2, 131-139, 2000). The unique feature of this phantom system is that it allows studies with, as well as without major degrading impacts from photon attenuation and Compton scattering. The specific aim of this work was to further develop the system with special reference to PET. Material and methods: The principle of the phantom concept is discrete sampling of 3D objects by a series of equidistant 2D planes. The 2D planes are a digitised set of 2D sections, representing the radioactivity distribution in the object of interest. Using a grey scale related to the radioactivity concentration, selected images are printed by radioactive ink on thin paper sheets and stacked into the 3D structure with low-density or with tissue equivalent material in between. Using positron emitting radionuclides, the paper sheets alone may not be sufficiently thick to avoid annihilation losses due to escaping positrons. In order to investigate the amount of additional material needed, a spot of radioactivity ( 18 F) was printed out and subsequently covered by adding thin plastic films (0.055mm) on both sides of the paper. Short PET scans (ECAT 921) were performed and the count-rate was registered after each additional layer of plastic cover. A first prototype, a cylindrical cold-spot phantom was constructed on the basis of these results. Nine identical sheets were printed out and first mounted in between 4 mm plates of polystyrene (density 1.04 g/cm 3 ). After a PET-scan, the paper sheets were re-mounted in between a low-density material (Divinycell, H30, density 0.03 g/cm 3 ) before repeating the PET scan. Results: For 18 F, the number of registered annihilation photons increased with increasing number of plastic sheets from 70% for the pure paper sheet to about 100% with 0.5 mm plastic cover on each side. PET of the low-density stacked cold spot phantom

  18. Mammography dosimetry using an in-house developed polymethyl methacrylate phantom

    International Nuclear Information System (INIS)

    Sharma, R.; Sharma, S. D.; Mayya, Y. S.; Chourasiya, G.

    2012-01-01

    Phantom-based measurements in mammography are well-established for quality assurance (QA) and quality control (QC) procedures involving equipment performance and comparisons of X-ray machines. Polymethyl methacrylate (PMMA) is among the best suitable materials for simulation of the breast. For carrying out QA/QC exercises in India, a mammographic PMMA phantom with engraved slots for keeping thermoluminescence dosemeters (TLD) has been developed. The radiation transmission property of the developed phantom was compared with the commercially available phantoms for verifying its suitability for mammography dosimetry. The breast entrance exposure (BEE), mean glandular dose (MGD), percentage depth dose (PDD), percentage surface dose distribution (PSDD), calibration testing of automatic exposure control (AEC) and density control function of a mammography machine were measured using this phantom. MGD was derived from the measured BEE following two different methodologies and the results were compared. The PDD and PSDD measurements were carried out using LiF: Mg, Cu, P chips. The in-house phantom was found comparable with the commercially available phantoms. The difference in the MGD values derived using two different methods were found in the range of 17.5-32.6 %. Measured depth ranges in the phantom lie between 0.32 and 0.40 cm for 75 % depth dose, 0.73 and 0.92 cm for 50 % depth dose, and 1.54 and 1.78 cm for 25 % depth dose. Higher PSDD value was observed towards chest wall edge side of the phantom, which is due to the orientation of cathode-anode axis along the chest wall to the nipple direction. Results obtained for AEC configuration testing shows that the observed mean optical density (O.D) of the phantom image was 1.59 and O.D difference for every successive increase in thickness of the phantom was within ±0.15 O.D. Under density control function testing, at -2 and -1 density settings, the variation in film image O.D was within ±0.15 O.D of the normal density

  19. Focus Groups Investigating Mental Health Attitudes and Beliefs of Parents and Teachers in South Lebanon: Are They Culturally Determined?

    Science.gov (United States)

    Doumit, Myrna A A; Farhood, Laila F; Hamady, Carmen

    2018-05-01

    The wars that Lebanon had endured led to a devastating number of deaths, injuries, and displacements. Such tragedies have detrimentally affected its civilians psychologically. To identify knowledge, attitudes, and practices of teachers and parents concerning child/adolescent mental health. Using purposeful sampling, five focus groups were conducted with teachers and parents of students from elementary, middle, and secondary levels in two private hub schools in South Lebanon. A total of 27 teachers and 18 parents participated separately in focus groups. Three themes emerged: (a) Mental health care is a priority for overall health, (b) Mental illness is a cultural taboo, and (c) There is a need for better education and cultural understanding about mental health. This is the first study in Lebanon directly targeted at parents' and teachers' mental health concerns. Such findings will add to transcultural nursing knowledge about the importance of mental health care.

  20. Cochrane review: behavioural and cognitive-behavioural group-based parenting programmes for early-onset conduct problems in children aged 3 to 12 years (Review).

    Science.gov (United States)

    Furlong, Mairead; McGilloway, Sinead; Bywater, Tracey; Hutchings, Judy; Smith, Susan M; Donnelly, Michael

    2013-03-07

    Early-onset child conduct problems are common and costly. A large number of studies and some previous reviews have focused on behavioural and cognitive-behavioural group-based parenting interventions, but methodological limitations are commonplace and evidence for the effectiveness and cost-effectiveness of these programmes has been unclear. To assess the effectiveness and cost-effectiveness of behavioural and cognitive-behavioural group-based parenting programmes for improving child conduct problems, parental mental health and parenting skills. We searched the following databases between 23 and 31 January 2011: CENTRAL (2011, Issue 1), MEDLINE (1950 to current), EMBASE (1980 to current), CINAHL (1982 to current), PsycINFO (1872 to current), Social Science Citation Index (1956 to current), ASSIA (1987 to current), ERIC (1966 to current), Sociological Abstracts (1963 to current), Academic Search Premier (1970 to current), Econlit (1969 to current), PEDE (1980 to current), Dissertations and Theses Abstracts (1980 to present), NHS EED (searched 31 January 2011), HEED (searched 31 January 2011), DARE (searched 31 January 2011), HTA (searched 31 January 2011), mRCT (searched 29 January 2011). We searched the following parent training websites on 31 January 2011: Triple P Library, Incredible Years Library and Parent Management Training. We also searched the reference lists of studies and reviews. We included studies if: (1) they involved randomised controlled trials (RCTs) or quasi-randomised controlled trials of behavioural and cognitive-behavioural group-based parenting interventions for parents of children aged 3 to 12 years with conduct problems, and (2) incorporated an intervention group versus a waiting list, no treatment or standard treatment control group. We only included studies that used at least one standardised instrument to measure child conduct problems. Two authors independently assessed the risk of bias in the trials and the methodological quality of

  1. Porous phantoms for PET and SPECT performance evaluation and quality assurance

    International Nuclear Information System (INIS)

    DiFilippo, Frank P.; Price, James P.; Kelsch, Daniel N.; Muzic, Raymond F. Jr.

    2004-01-01

    Characterization of PET and SPECT imaging performance often requires phantoms with complex radionuclide distributions. For example, lesion detection studies use multiple spherical regions of specific target-to-background ratios to simulate cancerous lesions. Such complex distributions are typically created using phantoms with multiple fillable chambers. However, such phantoms are typically difficult and time-consuming to prepare accurately and reproducibly. A new approach using a single-chamber phantom with a porous core can overcome these difficulties. Methods: Prototypes of two designs of porous core phantoms were produced and evaluated. The 'hot spheres' phantom contained a multitude of simulated spherical lesions with diameters ranging from 6.35 to 25.4 mm ('multi-resolution' slice) and with lesion-to-background ratios ranging from 1.6 to 4.4 ('multi-contrast' slice). The 'multi-attenuation' phantom consisted of two halves. One half contained a porous core to produce regions of different attenuation but uniform activity. The other half mimicked the NEMA-94 design with cold inserts of different attenuation. Results: Both phantoms produced the expected radionuclide distributions while requiring the preparation of only a single radionuclide solution and with much reduced preparation time. In images taken on clinical PET and SPECT scanners, the porous core structures were found to contribute negligible background noise or artifact. The measured lesion-to-background ratios from the hot spheres phantom differed slightly from calculated values, with the differences attributed mainly to uncertainty in pore diameter. The measured attenuation coefficients from the multi-attenuation phantom agreed well with expected values. However, it was found that trapped air bubbles due to manufacturing defects in the porous core could potentially cause quantitative errors. Conclusion: The hot spheres and multi-attenuation porous phantoms exhibited a wide range of imaging features

  2. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Science.gov (United States)

    Walker, Christopher M; Lee, Jaehyuk; Ramirez, Marc S; Schellingerhout, Dawid; Millward, Steven; Bankson, James A

    2013-01-01

    In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  3. A catalyzing phantom for reproducible dynamic conversion of hyperpolarized [1-¹³C]-pyruvate.

    Directory of Open Access Journals (Sweden)

    Christopher M Walker

    Full Text Available In vivo real time spectroscopic imaging of hyperpolarized ¹³C labeled metabolites shows substantial promise for the assessment of physiological processes that were previously inaccessible. However, reliable and reproducible methods of measurement are necessary to maximize the effectiveness of imaging biomarkers that may one day guide personalized care for diseases such as cancer. Animal models of human disease serve as poor reference standards due to the complexity, heterogeneity, and transient nature of advancing disease. In this study, we describe the reproducible conversion of hyperpolarized [1-¹³C]-pyruvate to [1-¹³C]-lactate using a novel synthetic enzyme phantom system. The rate of reaction can be controlled and tuned to mimic normal or pathologic conditions of varying degree. Variations observed in the use of this phantom compare favorably against within-group variations observed in recent animal studies. This novel phantom system provides crucial capabilities as a reference standard for the optimization, comparison, and certification of quantitative imaging strategies for hyperpolarized tracers.

  4. Studies on Phantom Vibration and Ringing Syndrome among Postgraduate Students

    Directory of Open Access Journals (Sweden)

    Atul Kumar Goyal

    2015-03-01

    Full Text Available Phantom vibrations and ringing of mobile phones are prevalent hallucinations in the general population. They might be considered as a normal brain mechanism. The aim of this study was to establish the prevalence of Phantom vibrations and ringing syndrome among students and to assess factors associated it. The survey of 300 postgraduate students belonging to different field of specialization was conducted at Kurukshetra University. 74% of students were found to have both Phantom vibrations and ringing syndrome. Whereas 17% of students felt Phantom vibration exclusively and 4% students face only Phantom ringing syndrome. Both the syndrome occurs more fervent in students who kept their mobile phone in shirt or jean pocket than to who kept mobile in handbag. 75% of students felt vibration or ringing even when the phone is switched off or phone was not in their pocket. Also the frequency of both the syndrome is directly proportional to the duration of mobile phone use and person emotional behavior. Although most of students agree that the Phantom syndrome did not bother them but some students deals with anxiety when they feel symptoms associated with Phantom syndrome. By using mobile phones in proper way, one can avoid these syndromes, or at least can ameliorate the symptoms.

  5. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-12-01

    The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements-including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth-were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light-tissue interactions and characterizing biophotonic system performance.

  6. Monte Carlo dose calculations for phantoms with hip prostheses

    International Nuclear Information System (INIS)

    Bazalova, M; Verhaegen, F; Coolens, C; Childs, P; Cury, F; Beaulieu, L

    2008-01-01

    Computed tomography (CT) images of patients with hip prostheses are severely degraded by metal streaking artefacts. The low image quality makes organ contouring more difficult and can result in large dose calculation errors when Monte Carlo (MC) techniques are used. In this work, the extent of streaking artefacts produced by three common hip prosthesis materials (Ti-alloy, stainless steel, and Co-Cr-Mo alloy) was studied. The prostheses were tested in a hypothetical prostate treatment with five 18 MV photon beams. The dose distributions for unilateral and bilateral prosthesis phantoms were calculated with the EGSnrc/DOSXYZnrc MC code. This was done in three phantom geometries: in the exact geometry, in the original CT geometry, and in an artefact-corrected geometry. The artefact-corrected geometry was created using a modified filtered back-projection correction technique. It was found that unilateral prosthesis phantoms do not show large dose calculation errors, as long as the beams miss the artefact-affected volume. This is possible to achieve in the case of unilateral prosthesis phantoms (except for the Co-Cr-Mo prosthesis which gives a 3% error) but not in the case of bilateral prosthesis phantoms. The largest dose discrepancies were obtained for the bilateral Co-Cr-Mo hip prosthesis phantom, up to 11% in some voxels within the prostate. The artefact correction algorithm worked well for all phantoms and resulted in dose calculation errors below 2%. In conclusion, a MC treatment plan should include an artefact correction algorithm when treating patients with hip prostheses

  7. Assembling of a phantom for quality control in pediatric radiodiagnosis

    International Nuclear Information System (INIS)

    Oliveira, Silvana Carvalho de; Ghilardi Netto, Thomaz; Trad, Clovis Simao; Brochi, Marco Aurelio Corte; Rocha, Sergio Luis

    1996-01-01

    The adaptation of an homogeneous phantom equivalent to an adult patient is presented for the valuation of pediatric radiologic images. The phantom consists basically of two plastic (methyl methacrylate) slabs, each 2.5 cm tick and two aluminium slabs, 0.5 and 1.0 mm thick. The system can simulate the chest, the skull or pelvis, and the extremities. The phantom also enables the equipment calibration, in order to reach the best radiographic image. After calibration of the equipment for several kVp and m As combinations, a phantom with known details and equivalent thickness was used to produce images. These radiographs allowed the choice of the best combination to be used. The entrance surface doses are presented for several combinations used with the pelvis and chest phantoms

  8. Neutron production in a spherical phantom aboard ISS

    International Nuclear Information System (INIS)

    Tasbaz, A.; Machrafi, R.

    2012-01-01

    As part of an ongoing research program on radiation monitoring on International Space Station (ISS) that was established to analyze the radiation exposure levels onboard the ISS using different radiation instruments and a spherical phantom to simulate human body. Monte Carlo transport code was used to simulate the interaction of high energy protons and neutrons with the spherical phantom currently onboard ISS. The phantom has been exposed to individual proton energies and to a spectrum of neutrons. The internal to external neutron flux ratio was calculated and compared to the experimental data, recently, measured on the ISS. (author)

  9. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    Science.gov (United States)

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Whole-body detector calibrating with a modular phantom

    Energy Technology Data Exchange (ETDEWEB)

    Minev, L; Boshkova, T; Uzunov, P [Sofia Univ. (Bulgaria). Fizicheski Fakultet

    1996-12-31

    Human body models (phantoms) of various size and weight are produced in order to calibrate gamma spectrometers for accurate activity measurement. The phantoms are built of separate modules with mass of 0.5 kg and size 20 x 14 x 2 cm. There are modules with standard Eu-152 and Am-241 radioactivity designed for homogenous radioactivity imitating and critical organs moulding, as well as `zero` -phantom modules without activity imitating a standard human body. Human organs are modelled by 11 x 9 x 0.5 cm modules with 0.16 kg mass. The phantoms have been used to obtain calibration curves and absolute efficiencies for selected energies of radionuclides expected to be found in the Kozloduy NPP staff. It is shown that the efficiency depends not only on the mass but on the geometric size of the measured object. Scanning of phantoms has been carried out and a profile of activity obtained. The profile consists of an abrupt rising of the sum of pulses (measuring time - 20 s) when the detector passes from neck to chest, a plateau when it moves over the head or the trunk and gradual decrease over the legs. Profiles of activity in organs are best obtained with a lead collimator. 4 refs., 7 figs., 2 tabs.

  11. Whole-body detector calibrating with a modular phantom

    International Nuclear Information System (INIS)

    Minev, L.; Boshkova, T.; Uzunov, P.

    1995-01-01

    Human body models (phantoms) of various size and weight are produced in order to calibrate gamma spectrometers for accurate activity measurement. The phantoms are built of separate modules with mass of 0.5 kg and size 20 x 14 x 2 cm. There are modules with standard Eu-152 and Am-241 radioactivity designed for homogenous radioactivity imitating and critical organs moulding, as well as 'zero' -phantom modules without activity imitating a standard human body. Human organs are modelled by 11 x 9 x 0.5 cm modules with 0.16 kg mass. The phantoms have been used to obtain calibration curves and absolute efficiencies for selected energies of radionuclides expected to be found in the Kozloduy NPP staff. It is shown that the efficiency depends not only on the mass but on the geometric size of the measured object. Scanning of phantoms has been carried out and a profile of activity obtained. The profile consists of an abrupt rising of the sum of pulses (measuring time - 20 s) when the detector passes from neck to chest, a plateau when it moves over the head or the trunk and gradual decrease over the legs. Profiles of activity in organs are best obtained with a lead collimator. 4 refs., 7 figs., 2 tabs

  12. Capturing the Perceived Phantom Limb through Virtual Reality

    Directory of Open Access Journals (Sweden)

    Christian Rogers

    2016-01-01

    Full Text Available Phantom limb is the sensation amputees may feel when the missing limb is still attached to the body and is still moving as it would if it still existed. Despite there being between 50 and 80% of amputees who report neuropathic pain, also known as phantom limb pain (PLP, there is still little understanding of why PLP occurs. There are no fully effective long-term treatments available. One of the struggles with PLP is the difficulty for amputees to describe the sensations of their phantom limbs. The sensations may be of a limb that is in a position that is impossible for a normal limb to attain. The goal of this project was to treat those with PLP by developing a system to communicate the sensations those with PLP were experiencing accurately and easily through various hand positions using a model arm with a user friendly interface. The system was developed with Maya 3D animation software, the Leap Motion input device, and the Unity game engine. The 3D modeled arm was designed to mimic the phantom sensation being able to go beyond normal joint extensions of regular arms. The purpose in doing so was to obtain a true 3D visualization of the phantom limb.

  13. Water content contribution in calculus phantom ablation during Q-switched Tm:YAG laser lithotripsy.

    Science.gov (United States)

    Zhang, Jian J; Rajabhandharaks, Danop; Xuan, Jason Rongwei; Wang, Hui; Chia, Ray W J; Hasenberg, Tom; Kang, Hyun Wook

    2015-01-01

    Q-switched (QS) Tm:YAG laser ablation mechanisms on urinary calculi are still unclear to researchers. Here, dependence of water content in calculus phantom on calculus ablation performance was investigated. White gypsum cement was used as a calculus phantom model. The calculus phantoms were ablated by a total 3-J laser pulse exposure (20 mJ, 100 Hz, 1.5 s) and contact mode with N=15 sample size. Ablation volume was obtained on average 0.079, 0.122, and 0.391  mm3 in dry calculus in air, wet calculus in air, and wet calculus in-water groups, respectively. There were three proposed ablation mechanisms that could explain the effect of water content in calculus phantom on calculus ablation performance, including shock wave due to laser pulse injection and bubble collapse, spallation, and microexplosion. Increased absorption coefficient of wet calculus can cause stronger spallation process compared with that caused by dry calculus; as a result, higher calculus ablation was observed in both wet calculus in air and wet calculus in water. The test result also indicates that the shock waves generated by short laser pulse under the in-water condition have great impact on the ablation volume by Tm:YAG QS laser.

  14. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    Directory of Open Access Journals (Sweden)

    Camerin Hahn

    2012-01-01

    Full Text Available As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectric properties. We propose a systematic approach in designing phantoms that not only have dielectric properties close to breast tissues but also can be easily shaped to realistic physical models. The approach is based on regression model to match phantom's dielectric properties with the breast tissue dielectric properties found in Lazebnik et al. (2007. However, the methodology proposed here can be used to create phantoms for any tissue type as long as ex vivo, in vitro, or in vivo tissue dielectric properties are measured and available. Therefore, using this method, accurate benchmarking phantoms for testing emerging microwave imaging algorithms can be developed.

  15. Designing a compact MRI motion phantom

    Directory of Open Access Journals (Sweden)

    Schmiedel Max

    2016-09-01

    Full Text Available Even today, dealing with motion artifacts in magnetic resonance imaging (MRI is a challenging task. Image corruption due to spontaneous body motion complicates diagnosis. In this work, an MRI phantom for rigid motion is presented. It is used to generate motion-corrupted data, which can serve for evaluation of blind motion compensation algorithms. In contrast to commercially available MRI motion phantoms, the presented setup works on small animal MRI systems. Furthermore, retrospective gating is performed on the data, which can be used as a reference for novel motion compensation approaches. The motion of the signal source can be reconstructed using motor trigger signals and be utilized as the ground truth for motion estimation. The proposed setup results in motion corrected images. Moreover, the importance of preprocessing the MRI raw data, e.g. phase-drift correction, is demonstrated. The gained knowledge can be used to design an MRI phantom for elastic motion.

  16. Solid tissue simulating phantoms having absorption at 970 nm for diffuse optics

    Science.gov (United States)

    Kennedy, Gordon T.; Lentsch, Griffin R.; Trieu, Brandon; Ponticorvo, Adrien; Saager, Rolf B.; Durkin, Anthony J.

    2017-07-01

    Tissue simulating phantoms can provide a valuable platform for quantitative evaluation of the performance of diffuse optical devices. While solid phantoms have been developed for applications related to characterizing exogenous fluorescence and intrinsic chromophores such as hemoglobin and melanin, we report the development of a poly(dimethylsiloxane) (PDMS) tissue phantom that mimics the spectral characteristics of tissue water. We have developed these phantoms to mimic different water fractions in tissue, with the purpose of testing new devices within the context of clinical applications such as burn wound triage. Compared to liquid phantoms, cured PDMS phantoms are easier to transport and use and have a longer usable life than gelatin-based phantoms. As silicone is hydrophobic, 9606 dye was used to mimic the optical absorption feature of water in the vicinity of 970 nm. Scattering properties are determined by adding titanium dioxide, which yields a wavelength-dependent scattering coefficient similar to that observed in tissue in the near-infrared. Phantom properties were characterized and validated using the techniques of inverse adding-doubling and spatial frequency domain imaging. Results presented here demonstrate that we can fabricate solid phantoms that can be used to simulate different water fractions.

  17. Usefulness of ACR MRI phantom for quality assurance of MRI instruments

    International Nuclear Information System (INIS)

    Lee, Jung Whee; Ahn, Kook Jin; Lee, Seung Koo; Na, Dong Gyu; Oh, Chang Hyun; Chang, Yong Min; Lim, Tae Hwan

    2006-01-01

    To examine whether the ACR phantom could be used in quality standards for magnetic resonance imaging (MRI) instruments in Korea. We conducted the phantom test using the ACR MRI phantom in 20 MRI instruments currently used in Korea. According to ACR criteria, we acquired the phantom images which were then assessed by the following seven tests: geometric accuracy, high spatial resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low contrast object detectability. The phantom images were interpreted by three experienced radiologists according to ACR criteria. Then, we examined the failure rate of each test and evaluated the inter-observer variation in the measurements and test failure. The failure rate of each test could be broken into the following components: geometric accuracy (11-21%), high contrast spatial resolution (10-15%), slice thickness accuracy(6-22%), slice position accuracy (5-17%), image intensity uniformity (6%), percent signal ghosting (16%), and low contrast object detectability (8-10%). In this series, all the failure rates were less than 30%. In addition, no inter-observer variation was seen in the measurements and test failure. ACR MRI phantom promises to be established as the standard phantom for MRI instruments in Korea because of its objectivity in assessing the phantom images

  18. Tracked ultrasound calibration studies with a phantom made of LEGO bricks

    Science.gov (United States)

    Soehl, Marie; Walsh, Ryan; Rankin, Adam; Lasso, Andras; Fichtinger, Gabor

    2014-03-01

    In this study, spatial calibration of tracked ultrasound was compared by using a calibration phantom made of LEGO® bricks and two 3-D printed N-wire phantoms. METHODS: The accuracy and variance of calibrations were compared under a variety of operating conditions. Twenty trials were performed using an electromagnetic tracking device with a linear probe and three trials were performed using varied probes, varied tracking devices and the three aforementioned phantoms. The accuracy and variance of spatial calibrations found through the standard deviation and error of the 3-D image reprojection were used to compare the calibrations produced from the phantoms. RESULTS: This study found no significant difference between the measured variables of the calibrations. The average standard deviation of multiple 3-D image reprojections with the highest performing printed phantom and those from the phantom made of LEGO® bricks differed by 0.05 mm and the error of the reprojections differed by 0.13 mm. CONCLUSION: Given that the phantom made of LEGO® bricks is significantly less expensive, more readily available, and more easily modified than precision-machined N-wire phantoms, it prompts to be a viable calibration tool especially for quick laboratory research and proof of concept implementations of tracked ultrasound navigation.

  19. Efficiency factors for Phoswich based lung monitor using ICRP Voxel phantoms

    International Nuclear Information System (INIS)

    Manohari, M.; Mathiyarasu, R.; Rajagopal, V.; Jose, M.T.; Venkatraman, B.

    2016-01-01

    The actinide contamination in lungs is measured either using array of HPGe detector or Phoswich based lung monitors. This paper discusses the results obtained during numerical calibration of Phoswich based lung counting system using ICRP VOXEL phantoms. The results are also compared with measured efficiency values obtained using LLNL phantom. The efficiency factors of 241 Am present in the lungs for phoswich detector was simulated using ICRP male voxel phantom and compared with experimentally observed values using LLNL Phantom. The observed deviation is 12%. The efficiency of the same for female subjects was estimated using ICRP female voxel phantom for both supine and posterior geometries

  20. Reliability of the Emotion-Related Parenting Styles Scale across Gender and Parent Status Groups

    Science.gov (United States)

    Dunstan, Debra A.; Anderson, Donnah L.; Marks, Anthony D. G.

    2015-01-01

    Research Findings: Emotional and social competence are critical to a child's current and future well-being. A. D. Paterson et al. (2012) studied a sample of mothers and proposed that an adult's approach to the socialization of a child's emotions can be summarized in his or her parenting style as measured by the Emotion-Related Parenting Styles…

  1. Quality assessment of brain images by Hoffman phantom

    International Nuclear Information System (INIS)

    Karimian, A.R.; Saddad, F.; Mosalla, B.; Moradkhani, S.; Degbankhan, R.; Pouladi, M.

    2002-01-01

    The purpose of this investigation is using Hoffman brain phantom for quality assessment of brian images in SPECT system. There are the following standards for quality control in nuclear medicine: American Association of Physicists in Medicine, National Electrical Manufacturers Association, International Electromechanical Commission, International Atomic Energy Agency. Each of the above standards has the following important orders: Physical inspection, Acceptance and Reference Testing, Periodic Q C tests (Daily, Weekly, Monthly, Quarterly, Annually). The above tests are simple physics measures. To more meaningful ones based on performance of some tasks related to clinical application it is better to use from organs' phantoms, such as: brain, cardiac, etc. In this research we made a comparison between normal and abnormal states of Hoffman brain phantom. Methods of Hoffman brain phantom was filled with a solution of Tc- 99 m (5 mCi) and water (1300 cc). this results: The investigation of small abnormalities strongly related to the operating conditions and deviation from best tuning state of the system

  2. Image fusion tool: Validation by phantom measurements

    International Nuclear Information System (INIS)

    Zander, A.; Geworski, L.; Richter, M.; Ivancevic, V.; Munz, D.L.; Muehler, M.; Ditt, H.

    2002-01-01

    Aim: Validation of a new image fusion tool with regard to handling, application in a clinical environment and fusion precision under different acquisition and registration settings. Methods: The image fusion tool investigated allows fusion of imaging modalities such as PET, CT, MRI. In order to investigate fusion precision, PET and MRI measurements were performed using a cylinder and a body contour-shaped phantom. The cylinder phantom (diameter and length 20 cm each) contained spheres (10 to 40 mm in diameter) which represented 'cold' or 'hot' lesions in PET measurements. The body contour-shaped phantom was equipped with a heart model containing two 'cold' lesions. Measurements were done with and without four external markers placed on the phantoms. The markers were made of plexiglass (2 cm diameter and 1 cm thickness) and contained a Ga-Ge-68 core for PET and Vitamin E for MRI measurements. Comparison of fusion results with and without markers was done visually and by computer assistance. This algorithm was applied to the different fusion parameters and phantoms. Results: Image fusion of PET and MRI data without external markers yielded a measured error of 0 resulting in a shift at the matrix border of 1.5 mm. Conclusion: The image fusion tool investigated allows a precise fusion of PET and MRI data with a translation error acceptable for clinical use. The error is further minimized by using external markers, especially in the case of missing anatomical orientation. Using PET the registration error depends almost only on the low resolution of the data

  3. Phantom positioning variation in the Gamma Knife® Perfexion dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Saraiva, Crystian [Hospital do Coracao, Sao Paulo, SP (Brazil)

    2015-07-01

    The use of small volume ionization chamber has become required for the dosimetry of equipment that use small radiation fields. A pinpoint ionization chamber is ideal for the dosimetry of a Gamma Knife® Perfexion (GKP) unit. In this work, this chamber was inserted into the phantom, and measurements were performed with the phantom in different positions, in order to verify if the change in the phantom positioning affects the dosimetry of the GKP. Three different phantom positions were performed. The variation in the result is within the range allowed for the dosimetry of a GKP equipment. (author)

  4. Breast phantom for mammary tissue characterization by near infrared spectroscopy

    International Nuclear Information System (INIS)

    Miranda, D A; Cristiano, K L; Gutiérrez, J C

    2013-01-01

    Breast cancer is a disease associated to a high morbidity and mortality in the entire world. In the study of early detection of breast cancer the development of phantom is so important. In this research we fabricate a breast phantom using a ballistic gel with special modifications to simulate a normal and abnormal human breast. Optical properties of woman breast in the near infrared region were modelled with the phantom we developed. The developed phantom was evaluated with near infrared spectroscopy in order to study its relation with breast tissue. A good optical behaviour was achieved with the model fabricated

  5. Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR

    International Nuclear Information System (INIS)

    Nagashima, Chieko; Uchiyama, Nachiko; Moriyama, Noriyuki; Nagata, Mio; Kobayashi, Hiroyuki; Sankoda, Katsuhiro; Saotome, Shigeru; Tagi, Masahiro; Kusunoki, Tetsurou

    2009-01-01

    Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital phantom. The values utilizing the 1Shot Phantom and those from the European guidelines and IEC standards were consistent, but the QC tests for the European guidelines and IEC standards methods took about six hours while the same QC tests using the 1Shot Phantom took 10 minutes or less including exposure of the phantom image, measurement, and analysis. In conclusion, the digital phantom and dedicated software proved very useful and produced improved analysis for mammography systems using FCR in clinical daily QC testing because of their objectivity and substantial time-saving convenience. (author)

  6. Parent education: an evaluation of STEP on abusive parents' perceptions and abuse potential.

    Science.gov (United States)

    Fennell, D C; Fishel, A H

    1998-01-01

    To examine the effects of a structured, time-limited parent training group on abusive or potentially abusive parents. A pretest-posttest control group design was used with consenting parents (N = 18) to examine the effects of Systematic Training for Effective Parenting (STEP) on abusive parents' perceptions of their children's behaviors and on the parents' potential to physically abuse. The Adlerian Parental Assessment of Child Behavior Scale and the Child Abuse Potential Inventory were used to measure treatment effects. After participating in STEP, abusive parents had significantly more positive perceptions of their children and were significantly less potentially abusive. Using volunteers, the project cost an average of $100 for each parent. The research lends empirical support to individual psychology and family systems theory. Future research is indicated using larger samples to examine lay vs. professional leadership of the groups, as well as comparisons of different parenting programs with abusive parents.

  7. Mom Power: preliminary outcomes of a group intervention to improve mental health and parenting among high-risk mothers.

    Science.gov (United States)

    Muzik, Maria; Rosenblum, Katherine L; Alfafara, Emily A; Schuster, Melisa M; Miller, Nicole M; Waddell, Rachel M; Stanton Kohler, Emily

    2015-06-01

    Maternal psychopathology and traumatic life experiences may adversely impact family functioning, the quality of the parent-child relationship and the attachment bond, placing the child's early social-emotional development at risk. Attachment-based parenting interventions may be particularly useful in decreasing negative outcomes for children exposed to risk contexts, yet high risk families frequently do not engage in programs to address mental health and/or parenting needs. This study evaluated the effects of Mom Power (MP), a 13-session parenting and self-care skills group program for high-risk mothers and their young children (age parenting competence, and engagement in treatment. Mothers were referred from community health providers for a phase 1 trial to assess feasibility, acceptability, and pilot outcomes. At baseline, many reported several identified risk factors, including trauma exposure, psychopathology, poverty, and single parenthood. Ninety-nine mother-child pairs were initially recruited into the MP program with 68 women completing and providing pre- and post-self-report measures assessing demographics and trauma history (pre-assessment only), maternal mental health (depression and post-traumatic stress disorder (PTSD)), parenting, and intervention satisfaction. Results indicate that MP participation was associated with reduction in depression, PTSD, and caregiving helplessness. A dose response relationship was evident in that, despite baseline equivalence, women who attended ≥70 % of the 10 groups (completers; N = 68) improved on parenting and mental health outcomes, in contrast to non-completers (N = 12). Effects were most pronounced for women with a mental health diagnosis at baseline. The intervention was perceived as helpful and user-friendly. Results indicate that MP is feasible, acceptable, and holds promise for improving maternal mental health and parenting competence among high-risk dyads. Further research is warranted to evaluate

  8. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-01-01

    Abstract. The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements—including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth—were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light–tissue interactions and characterizing biophotonic system performance. PMID:26662064

  9. Parenting and globalization in western countries: explaining differences in parent-child interactions.

    Science.gov (United States)

    Prevoo, Mariëlle Jl; Tamis-LeMonda, Catherine S

    2017-06-01

    We review research on intra-cultural differences in parenting, and the sources of those differences. Ethnic-minority parents differ from majority parents in parenting values, childrearing goals and resources-differences that affect parenting practices and children's development. Within-country comparisons indicate less sensitivity, more authoritarian discipline, less child-focused communications, and less engagement in learning activities in ethnic-minority compared to ethnic-majority parents, which help account for disparities in children. Despite group differences in parenting, associations between parenting and child development generalize across cultures, with rare exceptions. However, a focus on intra-cultural differences is based on comparisons of group 'averages', which masks the enormous variation within ethnic-minority samples. Within-group variation can be partly explained by stressors associated with low socioeconomic status (SES), acculturation and discrimination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Quantification of breast density using dual-energy mammography with liquid phantom calibration

    International Nuclear Information System (INIS)

    Lam, Alfonso R; Ding, Huanjun; Molloi, Sabee

    2014-01-01

    Breast density is a widely recognized potential risk factor for breast cancer. However, accurate quantification of breast density is a challenging task in mammography. The current use of plastic breast-equivalent phantoms for calibration provides limited accuracy in dual-energy mammography due to the chemical composition of the phantom. We implemented a breast-equivalent liquid phantom for dual-energy calibration in order to improve the accuracy of breast density measurement. To design these phantoms, three liquid compounds were chosen: water, isopropyl alcohol, and glycerol. Chemical compositions of glandular and adipose tissues, obtained from NIST database, were used as reference materials. Dual-energy signal of the liquid phantom at different breast densities (0% to 100%) and thicknesses (1 to 8 cm) were simulated. Glandular and adipose tissue thicknesses were estimated from a higher order polynomial of the signals. Our results indicated that the linear attenuation coefficients of the breast-equivalent liquid phantoms match those of the target material. Comparison between measured and known breast density data shows a linear correlation with a slope close to 1 and a non-zero intercept of 7%, while plastic phantoms showed a slope of 0.6 and a non-zero intercept of 8%. Breast density results derived from the liquid calibration phantoms showed higher accuracy than those derived from the plastic phantoms for different breast thicknesses and various tube voltages. We performed experimental phantom studies using liquid phantoms and then compared the computed breast density with those obtained using a bovine tissue model. The experimental data and the known values were in good correlation with a slope close to 1 (∼1.1). In conclusion, our results indicate that liquid phantoms are a reliable alternative for calibration in dual-energy mammography and better reproduce the chemical properties of the target material. (paper)

  11. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  12. But I Trust My Teen: Parents' Attitudes and Response to a Parental Monitoring Intervention

    Directory of Open Access Journals (Sweden)

    Aaron Metzger

    2012-01-01

    Full Text Available Parental knowledge gained from monitoring activities protects against adolescent risk involvement. Parental monitoring approaches are varied and may be modified with successful interventions but not all parents or adolescents respond to monitoring programs the same way. 339 parent-adolescent dyads randomized to receive a parental monitoring intervention and 169 parent-adolescent dyads in the control group were followed for one year over four measurement periods. Parent attitudes about the usefulness of monitoring, the importance of trust and respecting their teens’ privacy, and the appropriateness of adolescent risk-taking behavior and experimentation were examined as predictors of longitudinal change in parental monitoring and open communication. Similar effects were found in both the intervention and control group models regarding open communication. Parental attitudes impacted longitudinal patterns of teen-reported parent monitoring, and these patterns differed across experimental groups. In the intervention group, parents’ beliefs about the importance of trust and privacy were associated with a steeper decline in monitoring across time. Finally, parents’ attitudes about the normative nature of teen experimentation were associated with a quadratic parental monitoring time trend in the intervention but not the control group. These findings suggest that parental attitudes may impact how families respond to an adolescent risk intervention.

  13. A methodology to develop computational phantoms with adjustable posture for WBC calibration

    International Nuclear Information System (INIS)

    Fonseca, T C Ferreira; Vanhavere, F; Bogaerts, R; Hunt, John

    2014-01-01

    A Whole Body Counter (WBC) is a facility to routinely assess the internal contamination of exposed workers, especially in the case of radiation release accidents. The calibration of the counting device is usually done by using anthropomorphic physical phantoms representing the human body. Due to such a challenge of constructing representative physical phantoms a virtual calibration has been introduced. The use of computational phantoms and the Monte Carlo method to simulate radiation transport have been demonstrated to be a worthy alternative. In this study we introduce a methodology developed for the creation of realistic computational voxel phantoms with adjustable posture for WBC calibration. The methodology makes use of different software packages to enable the creation and modification of computational voxel phantoms. This allows voxel phantoms to be developed on demand for the calibration of different WBC configurations. This in turn helps to study the major source of uncertainty associated with the in vivo measurement routine which is the difference between the calibration phantoms and the real persons being counted. The use of realistic computational phantoms also helps the optimization of the counting measurement. Open source codes such as MakeHuman and Blender software packages have been used for the creation and modelling of 3D humanoid characters based on polygonal mesh surfaces. Also, a home-made software was developed whose goal is to convert the binary 3D voxel grid into a MCNPX input file. This paper summarizes the development of a library of phantoms of the human body that uses two basic phantoms called MaMP and FeMP (Male and Female Mesh Phantoms) to create a set of male and female phantoms that vary both in height and in weight. Two sets of MaMP and FeMP phantoms were developed and used for efficiency calibration of two different WBC set-ups: the Doel NPP WBC laboratory and AGM laboratory of SCK-CEN in Mol, Belgium. (paper)

  14. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  15. A methodology to develop computational phantoms with adjustable posture for WBC calibration

    Science.gov (United States)

    Ferreira Fonseca, T. C.; Bogaerts, R.; Hunt, John; Vanhavere, F.

    2014-11-01

    A Whole Body Counter (WBC) is a facility to routinely assess the internal contamination of exposed workers, especially in the case of radiation release accidents. The calibration of the counting device is usually done by using anthropomorphic physical phantoms representing the human body. Due to such a challenge of constructing representative physical phantoms a virtual calibration has been introduced. The use of computational phantoms and the Monte Carlo method to simulate radiation transport have been demonstrated to be a worthy alternative. In this study we introduce a methodology developed for the creation of realistic computational voxel phantoms with adjustable posture for WBC calibration. The methodology makes use of different software packages to enable the creation and modification of computational voxel phantoms. This allows voxel phantoms to be developed on demand for the calibration of different WBC configurations. This in turn helps to study the major source of uncertainty associated with the in vivo measurement routine which is the difference between the calibration phantoms and the real persons being counted. The use of realistic computational phantoms also helps the optimization of the counting measurement. Open source codes such as MakeHuman and Blender software packages have been used for the creation and modelling of 3D humanoid characters based on polygonal mesh surfaces. Also, a home-made software was developed whose goal is to convert the binary 3D voxel grid into a MCNPX input file. This paper summarizes the development of a library of phantoms of the human body that uses two basic phantoms called MaMP and FeMP (Male and Female Mesh Phantoms) to create a set of male and female phantoms that vary both in height and in weight. Two sets of MaMP and FeMP phantoms were developed and used for efficiency calibration of two different WBC set-ups: the Doel NPP WBC laboratory and AGM laboratory of SCK-CEN in Mol, Belgium.

  16. Computational high-resolution heart phantoms for medical imaging and dosimetry simulations

    Energy Technology Data Exchange (ETDEWEB)

    Gu Songxiang; Kyprianou, Iacovos [Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD (United States); Gupta, Rajiv, E-mail: songxiang.gu@fda.hhs.gov, E-mail: rgupta1@partners.org, E-mail: iacovos.kyprianou@fda.hhs.gov [Massachusetts General Hospital, Boston, MA (United States)

    2011-09-21

    Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are rendered under fluoroscopic guidance. Both invasive and non-invasive imaging modalities employ ionizing radiation and there is concern for deterministic and stochastic effects of radiation. Accurate simulation to optimize image quality with minimal radiation dose requires detailed, gender-specific anthropomorphic phantoms with anatomically correct heart and associated vasculature. Such phantoms are currently unavailable. This paper describes an open source heart phantom development platform based on a graphical user interface. Using this platform, we have developed seven high-resolution cardiac/coronary artery phantoms for imaging and dosimetry from seven high-quality CTA datasets. To extract a phantom from a coronary CTA, the relationship between the intensity distribution of the myocardium, the ventricles and the coronary arteries is identified via histogram analysis of the CTA images. By further refining the segmentation using anatomy-specific criteria such as vesselness, connectivity criteria required by the coronary tree and image operations such as active contours, we are able to capture excellent detail within our phantoms. For example, in one of the female heart phantoms, as many as 100 coronary artery branches could be identified. Triangular meshes are fitted to segmented high-resolution CTA data. We have also developed a visualization tool for adding stenotic lesions to the coronaries. The male and female heart phantoms generated so far have been cross-registered and entered in the mesh-based Virtual Family of phantoms with matched age/gender information. Any phantom in this family, along with user

  17. Computational high-resolution heart phantoms for medical imaging and dosimetry simulations

    International Nuclear Information System (INIS)

    Gu Songxiang; Kyprianou, Iacovos; Gupta, Rajiv

    2011-01-01

    Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are rendered under fluoroscopic guidance. Both invasive and non-invasive imaging modalities employ ionizing radiation and there is concern for deterministic and stochastic effects of radiation. Accurate simulation to optimize image quality with minimal radiation dose requires detailed, gender-specific anthropomorphic phantoms with anatomically correct heart and associated vasculature. Such phantoms are currently unavailable. This paper describes an open source heart phantom development platform based on a graphical user interface. Using this platform, we have developed seven high-resolution cardiac/coronary artery phantoms for imaging and dosimetry from seven high-quality CTA datasets. To extract a phantom from a coronary CTA, the relationship between the intensity distribution of the myocardium, the ventricles and the coronary arteries is identified via histogram analysis of the CTA images. By further refining the segmentation using anatomy-specific criteria such as vesselness, connectivity criteria required by the coronary tree and image operations such as active contours, we are able to capture excellent detail within our phantoms. For example, in one of the female heart phantoms, as many as 100 coronary artery branches could be identified. Triangular meshes are fitted to segmented high-resolution CTA data. We have also developed a visualization tool for adding stenotic lesions to the coronaries. The male and female heart phantoms generated so far have been cross-registered and entered in the mesh-based Virtual Family of phantoms with matched age/gender information. Any phantom in this family, along with user

  18. Creation of a High-fidelity, Low-cost Pediatric Skull Fracture Ultrasound Phantom.

    Science.gov (United States)

    Soucy, Zachary P; Mills, Lisa; Rose, John S; Kelley, Kenneth; Ramirez, Francisco; Kuppermann, Nathan

    2015-08-01

    Over the past decade, point-of-care ultrasound has become a common tool used for both procedures and diagnosis. Developing high-fidelity phantoms is critical for training in new and novel point-of-care ultrasound applications. Detecting skull fractures on ultrasound imaging in the younger-than-2-year-old patient is an emerging area of point-of-care ultrasound research. Identifying a skull fracture on ultrasound imaging in this age group requires knowledge of the appearance and location of sutures to distinguish them from fractures. There are currently no commercially available pediatric skull fracture models. We outline a novel approach to building a cost-effective, simple, high-fidelity pediatric skull fracture phantom to meet a unique training requirement. © 2015 by the American Institute of Ultrasound in Medicine.

  19. Young patients', parents', and survivors' communication preferences in paediatric oncology: Results of online focus groups

    Directory of Open Access Journals (Sweden)

    Kamps Willem A

    2007-11-01

    Full Text Available Abstract Background Guidelines in paediatric oncology encourage health care providers to share relevant information with young patients and parents to enable their active participation in decision making. It is not clear to what extent this mirrors patients' and parents' preferences. This study investigated communication preferences of childhood cancer patients, parents, and survivors of childhood cancer. Methods Communication preferences were examined by means of online focus groups. Seven patients (aged 8–17, 11 parents, and 18 survivors (aged 8–17 at diagnosis participated. Recruitment took place by consecutive inclusion in two Dutch university oncological wards. Questions concerned preferences regarding interpersonal relationships, information exchange and participation in decision making. Results Participants expressed detailed and multi-faceted views regarding their needs and preferences in communication in paediatric oncology. They agreed on the importance of several interpersonal and informational aspects of communication, such as honesty, support, and the need to be fully informed. Participants generally preferred a collaborative role in medical decision making. Differences in views were found regarding the desirability of the patient's presence during consultations. Patients differed in their satisfaction with their parents' role as managers of the communication. Conclusion Young patients' preferences mainly concur with current guidelines of providing them with medical information and enabling their participation in medical decision making. Still, some variation in preferences was found, which faces health care providers with the task of balancing between the sometimes conflicting preferences of young cancer patients and their parents.

  20. [Phantoms for the collection of genital secretions in stallions].

    Science.gov (United States)

    Klug, E; Brinkhoff, D; Flüge, A; Scherbarth, R; Essich, G; Kienzler, M

    1977-10-05

    Practical experiences of the phantom method for collection of genital secretions from stallions are reported. Taking a phantom used in the Richard-Götze-Haus Tierärztliche Hochschule Hannover as a prototype two further models slightly modified have been constructed, baring a flat hollow in the right side of the caudal phantom body for manual inserting of the Artificial Vagina. These three models fulfill four important conditions for routine use: (1) sufficient sexual attractivity for the stallions; 80-85% successful collections of presecretions out of a total of 1050 using the dummy and 70% successful semen collections from more than 240 in total; (2) solid and resistant construction; (3) easy cleaning and desinfection of the surface of the phantom to get representative samples; (4) firm installation on a hygienic floor.

  1. Phantom jam avoidance through in-car speed advice

    NARCIS (Netherlands)

    Suijs, L.C.W.; Wismans, Luc Johannes Josephus; Krol, L.; van Berkum, Eric C.

    2015-01-01

    The existence of phantom jams can be explained following the definition of Kerner & Konhäuser (1993) who state that a phantom jam occurs without the existence of a physical bottleneck and is caused by the imperfect driving style of road users under metastable traffic conditions. In order to prevent

  2. Prevalent hallucinations during medical internships: phantom vibration and ringing syndromes.

    Directory of Open Access Journals (Sweden)

    Yu-Hsuan Lin

    Full Text Available BACKGROUND: Phantom vibration syndrome is a type of hallucination reported among mobile phone users in the general population. Another similar perception, phantom ringing syndrome, has not been previously described in the medical literature. METHODS: A prospective longitudinal study of 74 medical interns (46 males, 28 females; mean age, 24.8±1.2 years was conducted using repeated investigations of the prevalence and associated factors of phantom vibration and ringing. The accompanying symptoms of anxiety and depression were evaluated with the Beck Anxiety and Depression Inventories before the internship began, and again at the third, sixth, and twelfth internship months, and two weeks after the internship ended. RESULTS: The baseline prevalence of phantom vibration was 78.1%, which increased to 95.9% and 93.2% in the third and sixth internship months. The prevalence returned to 80.8% at the twelfth month and decreased to 50.0% 2 weeks after the internship ended. The baseline prevalence of phantom ringing was 27.4%, which increased to 84.9%, 87.7%, and 86.3% in the third, sixth, and twelfth internship months, respectively. This returned to 54.2% two weeks after the internship ended. The anxiety and depression scores also increased during the internship, and returned to baseline two weeks after the internship. There was no significant correlation between phantom vibration/ringing and symptoms of anxiety or depression. The incidence of both phantom vibration and ringing syndromes significantly increased during the internship, and subsequent recovery. CONCLUSION: This study suggests that phantom vibration and ringing might be entities that are independent of anxiety or depression during evaluation of stress-associated experiences during medical internships.

  3. Evaluating a brief parental-education program for parents of young children.

    Science.gov (United States)

    Nicholson, B C; Janz, P C; Fox, R A

    1998-06-01

    The effectiveness of a brief parental-education program for 40 families with very young children was studied. Families were assigned to either a parental-education or waiting-list control group. The parental-education program included information and strategies drawn from developmental and cognitive psychology and social learning theory. Analysis showed that participating parents significantly reduced their use of corporal and verbal punishment, changed their parenting attitudes, and improved their perceptions of their children's behavior in comparison to the control group. Effects were maintained at six weeks follow-up. Results supported tailoring parental-education programs to the unique needs of participants.

  4. Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    Science.gov (United States)

    Salvati, Roberto; Hitti, Eric; Bellanger, Jean-Jacques; Saint-Jalmes, Hervé; Gambarota, Giulio

    2016-06-01

    Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. Various numerical phantoms with a given fat fraction, T2* and field map were designed. The k-space of numerical phantoms was converted into RF signals to generate virtual phantoms. MRI experiments were performed at 4.7T using a multi-gradient-echo sequence on virtual and physical phantoms. The data acquisition of virtual and physical phantoms was simultaneous. Decomposition of the water and fat signals was performed using a complex-based water-fat separation algorithm. Overall, a good agreement was observed between the fat fraction, T2* and phase map values of the virtual and numerical phantoms. In particular, fat fractions of 10.5±0.1 (vs 10% of the numerical phantom), 20.3±0.1 (vs 20%) and 30.4±0.1 (vs 30%) were obtained in virtual phantoms. The ViP MRI method allows for generating imaging phantoms that i) mimic water-fat systems and ii) can be analyzed with water-fat separation algorithms based on complex data. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Parental overprotection, perceived child vulnerability, and parenting stress: a cross-illness comparison.

    Science.gov (United States)

    Hullmann, Stephanie E; Wolfe-Christensen, Cortney; Ryan, Jamie L; Fedele, David A; Rambo, Philip L; Chaney, John M; Mullins, Larry L

    2010-12-01

    The current study sought to investigate differences in parenting capacity variables across four disease groups. Parents (N = 425), the majority of whom were mothers, of children with either cancer, asthma, Type 1 diabetes, or cystic fibrosis, completed measures of parental overprotection, perceived child vulnerability, and parenting stress. After controlling for significant demographic variables, parents of children with cystic fibrosis and asthma reported higher perceived child vulnerability than parents of children with either diabetes or cancer, while parents of children with asthma and diabetes reported higher parenting stress than parents of children with cancer or cystic fibrosis. No differences between disease groups were found for parental overprotection. The current study provides support for an illness-specific approach to understanding parenting capacity variables in the context of childhood chronic illnesses.

  6. Development of polygonal surface version of ICRP reference phantoms: Preliminary study for posture change

    International Nuclear Information System (INIS)

    Nguyen, Tat Thang; Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong

    2013-01-01

    Even though International Commission on Radiological Protection (ICRP) officially adopted a set of adult male and female voxel phantoms as the ICRP reference phantoms, there are several critical limitations due to the nature of voxel geometry and their low voxel resolutions. In order to overcome these limitations of the ICRP phantoms, we are currently developing polygonal surface version of ICRP reference phantoms by directly converting the ICRP voxel phantoms to polygonal surface geometries. Among the many advantages of the ICRP polygonal surface phantom, especially, it is flexible and deformable. In principle, it is, therefore, possible to make the posture-changed ICRP phantoms which can provide more accurate dose values for exposure situations strongly relevant to worker's postures. As a preliminary study for developing the posture-changed ICRP phantoms, in this work we changed the posture of the preliminary version of ICRP male polygon-surface phantom constructed in the previous study. Organ doses were then compared between original and posture-changed phantoms. In the present study, we successfully changed a posture of the preliminary version of ICRP male polygon-surface phantom to the walking posture. From this results, it was explicitly shown that the polygon-surface version of the ICRP phantoms can be sufficiently modified to be various postures with the posture-changing method used in this study. In addition, it was demonstrated that phantom's posture must be considered in certain exposure situations, which can differ dose values from the conventional standing-posture phantom

  7. Effectiveness of preventive support groups for children of mentally ill or addicted parents: a randomized controlled trial

    NARCIS (Netherlands)

    Santvoort, F. van; Hosman, C.M.H.; Doesum, K.T.M. van; Janssens, J.M.

    2014-01-01

    In various countries preventive support groups are offered to children of mentally ill and/or addicted parents to reduce the risk that they will develop problems themselves. This study assessed the effectiveness of Dutch support groups for children aged 8-12 years old in terms of reducing negative

  8. Parental Monitoring, Parent-Adolescent Communication, and Adolescents' Trust in Their Parents in China.

    Directory of Open Access Journals (Sweden)

    Liuhua Ying

    Full Text Available Trust is an important aspect of interpersonal relationships, but little is known about adolescents' interpersonal trust. The aim of the present study was to examine the associations among parental monitoring, parent-adolescent communication, and adolescents' trust in their parents in China.Data in this study were collected as part of the cross-sectional study of children in China. 3349 adolescents (female 48.6%, age range of 12-15 years were randomly selected from 35 secondary schools in April, 2009 and administered to the Adolescent Interpersonal Trust Scale, the Parental Monitoring Scale, and the Parent-Adolescent Communication Scale.Adolescents' trust in their parents was positively related to parental monitoring and parent-adolescent communication. Furthermore, parent-adolescent communication mediated the association between parental monitoring and adolescents' trust in their parents. The mediation model fit data of both genders and three age groups equally well.Parental monitoring and parent-adolescent communication play an importance role in fostering adolescents' trust in their parents.

  9. Apparent motion perception in lower limb amputees with phantom sensations: "obstacle shunning" and "obstacle tolerance".

    Science.gov (United States)

    Saetta, Gianluca; Grond, Ilva; Brugger, Peter; Lenggenhager, Bigna; Tsay, Anthony J; Giummarra, Melita J

    2018-03-21

    Phantom limbs are the phenomenal persistence of postural and sensorimotor features of an amputated limb. Although immaterial, their characteristics can be modulated by the presence of physical matter. For instance, the phantom may disappear when its phenomenal space is invaded by objects ("obstacle shunning"). Alternatively, "obstacle tolerance" occurs when the phantom is not limited by the law of impenetrability and co-exists with physical objects. Here we examined the link between this under-investigated aspect of phantom limbs and apparent motion perception. The illusion of apparent motion of human limbs involves the perception that a limb moves through or around an object, depending on the stimulus onset asynchrony (SOA) for the two images. Participants included 12 unilateral lower limb amputees matched for obstacle shunning (n = 6) and obstacle tolerance (n = 6) experiences, and 14 non-amputees. Using multilevel linear models, we replicated robust biases for short perceived trajectories for short SOA (moving through the object), and long trajectories (circumventing the object) for long SOAs in both groups. Importantly, however, amputees with obstacle shunning perceived leg stimuli to predominantly move through the object, whereas amputees with obstacle tolerance perceived leg stimuli to predominantly move around the object. That is, in people who experience obstacle shunning, apparent motion perception of lower limbs was not constrained to the laws of impenetrability (as the phantom disappears when invaded by objects), and legs can therefore move through physical objects. Amputees who experience obstacle tolerance, however, had stronger solidity constraints for lower limb apparent motion, perhaps because they must avoid co-location of the phantom with physical objects. Phantom limb experience does, therefore, appear to be modulated by intuitive physics, but not in the same way for everyone. This may have important implications for limb experience post

  10. Parenting Behavior, Quality of the Parent-Adolescent Relationship, and Adolescent Functioning in Four Ethnic Groups

    Science.gov (United States)

    Wissink, Inge B.; Dekovic, Maja; Meijer, Anne Marie

    2006-01-01

    The cross-ethnic similarity in the pattern of associations among parenting behavior (support and authoritative and restrictive control), the quality of the parent-adolescent relationship (disclosure and positive and negative quality), and several developmental outcomes (aggressive behavior, delinquent behavior, and global self-esteem) was tested.…

  11. Conflict Resolution in the Parent-Child, Marital, and Peer Contexts and Children's Aggression in the Peer Group: A Process-Oriented Cultural Perspective

    Science.gov (United States)

    Feldman, Ruth; Masalha, Shafiq; Derdikman-Eiron, Ruth

    2010-01-01

    Theories of socialization propose that children's ability to handle conflicts is learned at home through mechanisms of participation and observation--participating in parent-child conflict and observing the conflicts between parents. We assessed modes of conflict resolution in the parent-child, marriage, and peer-group contexts among 141 Israeli…

  12. Bioassay Phantoms Using Medical Images and Computer Aided Manufacturing

    International Nuclear Information System (INIS)

    Xu, X. Geroge

    2011-01-01

    A radiation bioassay program relies on a set of standard human phantoms to calibrate and assess radioactivity levels inside a human body for radiation protection and nuclear medicine imaging purposes. However, the methodologies in the development and application of anthropomorphic phantoms, both physical and computational, had mostly remained the same for the past 40 years. We herein propose a 3-year research project to develop medical image-based physical and computational phantoms specifically for radiation bioassay applications involving internally deposited radionuclides. The broad, long-term objective of this research was to set the foundation for a systematic paradigm shift away from the anatomically crude phantoms in existence today to realistic and ultimately individual-specific bioassay methodologies. This long-term objective is expected to impact all areas of radiation bioassay involving nuclear power plants, U.S. DOE laboratories, and nuclear medicine clinics.

  13. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Parenting Role's Tasks as Parents of Healthy and Disabled Children

    Directory of Open Access Journals (Sweden)

    Azade Riyahi

    2017-09-01

    Full Text Available Background The purpose of this study was to determine how to do parenting role's tasks as parents of healthy and disabled children younger than 7 years old in Iran (Arak. Materials and Methods In this cross-sectional study, the parenting role tasks questionnaire was completed for 120 parents of healthy children and 120 parents of disabled children with at least one child with disability and the parents were selected by convenience sampling method. T-test, Mann-Whitney test and analysis of variances was used to compare the scores between parents of healthy and disabled children based on studied variables including child age, parent age, child gender, parent education, family economic status, history of trauma and seizure in children was applied to perform the role of parents. Results: There was a significant difference of parent role in both groups of parents. There was observed a significant relationship between role of healthy children's parents and age of child (r=0.21, P=0.016, but not observed in disabled children's parents. In healthy children, there was no significant correlation between parent's role and maternal age. In contrast, in disabled children, there was found a significant difference (P= 0.04 with correlation coefficient of -0.18 representing the inverse relationship. Moreover, no relationship was found between history of seizure and performance of parenting role's tasks in the group of disabled children (P>0.05. Conclusion The performance of tasks of parenting role in two groups of parents of healthy children and disabled ones in four areas of primary care, education, leisure and improving cognitive level had significant difference. This difference in the area of improving the cognitive level was higher. Due to complications of disability, parents of these children pay more attention to other areas of care except of improving cognitive level. Therefore presence of disabled child has negative effect on the balance of the

  15. A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.

    Science.gov (United States)

    Maxwell, Adam D; Wang, Tzu-Yin; Yuan, Lingqian; Duryea, Alexander P; Xu, Zhen; Cain, Charles A

    2010-12-01

    Many ultrasound studies involve the use of tissue-mimicking materials to research phenomena in vitro and predict in vivo bioeffects. We have developed a tissue phantom to study cavitation-induced damage to tissue. The phantom consists of red blood cells suspended in an agarose hydrogel. The acoustic and mechanical properties of the gel phantom were found to be similar to soft tissue properties. The phantom's response to cavitation was evaluated using histotripsy. Histotripsy causes breakdown of tissue structures by the generation of controlled cavitation using short, focused, high-intensity ultrasound pulses. Histotripsy lesions were generated in the phantom and kidney tissue using a spherically focused 1-MHz transducer generating 15 cycle pulses, at a pulse repetition frequency of 100 Hz with a peak negative pressure of 14 MPa. Damage appeared clearly as increased optical transparency of the phantom due to rupture of individual red blood cells. The morphology of lesions generated in the phantom was very similar to that generated in kidney tissue at both macroscopic and cellular levels. Additionally, lesions in the phantom could be visualized as hypoechoic regions on a B-mode ultrasound image, similar to histotripsy lesions in tissue. High-speed imaging of the optically transparent phantom was used to show that damage coincides with the presence of cavitation. These results indicate that the phantom can accurately mimic the response of soft tissue to cavitation and provide a useful tool for studying damage induced by acoustic cavitation. Copyright © 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Parenting children with down syndrome: An analysis of parenting styles, parenting dimensions, and parental stress.

    Science.gov (United States)

    Phillips, B Allyson; Conners, Frances; Curtner-Smith, Mary Elizabeth

    2017-09-01

    Effective parenting is vital for a child's development. Although much work has been conducted on parenting typically developing children, little work has examined parenting children with Down syndrome. The purpose of the current study was to compare the parenting styles and dimensions in mothers of children with DS and mothers of TD children. Thirty-five mothers of children with DS and 47 mothers of TD children completed questionnaires about parenting, parental stress, child behavior problems, and child executive function. We found that mothers of children with DS use an authoritative parenting style less and a permissive parenting style more than mothers of TD children. Additionally, we found that mothers of children with DS use reasoning/induction and verbal hostility less and ignoring misbehavior more than mothers of TD children. All of these differences, except for those of reasoning/induction, were at least partially accounted for by the higher levels of parental stress in the DS group. Parenting interventions should be focused on reducing parental stress and training mothers to parent under stress in an effort to improve parenting techniques, which would, in theory, improve long-term child outcomes for children with DS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. AdS Black Hole with Phantom Scalar Field

    Directory of Open Access Journals (Sweden)

    Limei Zhang

    2017-01-01

    Full Text Available We present an AdS black hole solution with Ricci flat horizon in Einstein-phantom scalar theory. The phantom scalar fields just depend on the transverse coordinates x and y, which are parameterized by the parameter α. We study the thermodynamics of the AdS phantom black hole. Although its horizon is a Ricci flat Euclidean space, we find that the thermodynamical properties of the black hole solution are qualitatively the same as those of AdS Schwarzschild black hole. Namely, there exists a minimal temperature and the large black hole is thermodynamically stable, while the smaller one is unstable, so there is a so-called Hawking-Page phase transition between the large black hole and the thermal gas solution in the AdS space-time in Poincare coordinates. We also calculate the entanglement entropy for a strip geometry dual to the AdS phantom black holes and find that the behavior of the entanglement entropy is qualitatively the same as that of the black hole thermodynamical entropy.

  18. Computer phantoms for simulating ultrasound B-mode and CFM images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Munk, Peter

    1997-01-01

    in a file that defines their position and amplitude. Adjusting the number of scatterers and their relative amplitude yields the proper image.Five different computer phantoms are described. The first one consists of a number of point targets. It is used for studying the point spread function as a function...... of spatial position, and can give an indication of sidelobe levels and focusing abilities. The second phantom contains a number of cysts and point tagets along with a homogeneous speckle pattern. This is used for investigating image contrast, and the system's ability to detect low-contrast objects. The third...... phantom is for realistic clinical imaging. It contains the image of a 12 week old fetus, where the placenta and the upper body of the fetus is visible. This phantom gives an indication of the whole system's capability for real imaging. The current fetus phantom is only two-dimensional, as it is constant...

  19. Construction of cardiac anthropomorphic phantom for simulation of radiological exams

    International Nuclear Information System (INIS)

    Bandeira, C.K.; Vieira Neto, H.; Vieira, M.P.M.M.

    2017-01-01

    Phantoms are simulating objects of structures of the human body and can be applied in the quality control and calibration of radiological equipment. The aim of the work is the development of a cardiac anthropomorphic phantom to assist in the elaboration of protocols of dynamic studies that demonstrate the blood circulation inside the cardiac chambers. For the construction of the phantom was used latex, applied in layers on an anatomical model of heart, having been constructed the cardiac chambers and atrioventricular valves. Cardiac chambers were connected to the cannulas for fluid injection and simulation of the circulatory system. The constructed phantom presents anthropomorphic characteristics and allows the circulation of the fluid without reflux, but the thickness of the catheters used does not yet allow flows of greater order of magnitude. This phantom has the potential to be used in the dynamic simulation of cardiac exams, contributing to the elaboration and adequacy of computed tomography protocols

  20. Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes.

    Directory of Open Access Journals (Sweden)

    Sossena Wood

    Full Text Available The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications.An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource. The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner.Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla and the scattering parameter (measured using a network analyzer were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer.The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI.

  1. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  2. Dosimetric characteristics of water equivalent for two solid water phantoms

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Xun; Ren Jiangping

    2011-01-01

    Objective: To investigate the water equivalent of two solid water phantoms. Methods: The X-ray and electron beam depth-ion curves were measured in water and two solid water phantoms, RW3 and Virtual Water. The water-equivalency correction factors for the two solid water phantoms were compared. We measured and calculated the range sealing factors and the fluence correction factors for the two solid water phantoms in the case of electron beams. Results: The average difference between the measured ionization in solid water phantoms and water was 0.42% and 0.16% on 6 MV X-ray (t=-6.15, P=0.001 and t=-1.65, P=0.419) and 0.21% and 0.31% on 10 MV X-ray (t=1.728, P=0.135 and t=-2.296, P=0.061), with 17.4% and 14.5% on 6 MeV electron beams (t=-1.37, P=0.208 and t=-1.47, P=0.179) and 7.0% and 6.0% on 15 MeV electron beams (t=-0.58, P=0.581 and t=-0.90, P=0.395). The water-equivalency correction factors for the two solid water phantoms varied slightly largely, F=58.54, P=0.000 on 6 MV X-ray, F=0.211, P=0.662 on 10 MV X-ray, F=0.97, P=0.353 on 6 MeV electron beams, F=0.14, P=0.717 on 15 MeV electron beams. However, they were almost equal to 1 near the reference depths. The two solid water phantoms showed a similar tread of C pl increasing (F=26.40, P=0.014) and h pl decreasing (F=7.45, P=0.072) with increasing energy. Conclusion: The solid water phantom should undergo a quality control test before being clinical use. (authors)

  3. Early and effective use of ketamine for treatment of phantom limb pain

    Directory of Open Access Journals (Sweden)

    Harsha Shanthanna

    2010-01-01

    Full Text Available Treatment for phantom limb pain is difficult and challenging. There is often suboptimum treatment with fewer than 10% receiving lasting relief. Treatments based broadly on other neuropathic pains may not be appropriate for a clinical success. We report a case of phantom limb pain, which proved resistant to multiple analgesics, including opioids and continuous epidural blockade. Treatment with intravenous (IV ketamine as an alternate day infusion, gave complete remission of phantom limb pain. This demonstrates an early and effective use of a potent NMDA antagonist for treatment of phantom limb pain. Mechanisms underlying phantom limb pain are briefly discussed.

  4. Neutron measurements with a tissue-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J W [Health Physics Division, Atomic Energy Establishment, Harwell (United Kingdom)

    1962-03-15

    This Appendix 3E of the dosimetry experiment at the R-B reactor describes the apparatus used and presents the obtained results. The phantom used was a 1/4-inch thick polythene container, 60 cm high, of elliptical cross-section, with a major axis of 36 cm and a minor axis of 20 cm. This was filled with an approximately tissue-equivalent liquid. A light but rigid internal framework of Perspex supported a series of small detectors through the phantom. The detectors used in the first high-level run at Vinca, to measure flux above 0.5 MeV, were 0.5-cm wide track plates wrapped in cadmium foil. Each track plate was a sandwich of two Ilford El 50 - mu emulsions, with glass backing, separated by a 250-mu polythene radiator, and was oriented at an angle of 45 deg to the front surface of the phantom. Under these conditions the response is constant with neutron energy between 0.5 MeV and 8 MeV at 1.26 X 10 sup - sup 3 tracks/neutron to within +- 15%. The detectors used in the second high-level run were gold foils (260 mg/cm sup 2 thick) for determination of the show neutron distribution. Previous experiments with 0.13 MeV, 2.5 MeV, 14 MeV and Po-Be neutrons have shown that the shape of the curve through a phantom obtained from these gold foils is the same as that given by either manganese foils or sodium samples despite the difference in resonance integrals. From the relaxation length of the neutron flux in the phantom, as measured by the track plates, the mean energy of the neutrons with energies greater than 0.5 MeV may be found by comparison with the relaxation lengths obtained by irradiation of the phantom with monoenergetic neutrons. The results of these experiments are given. Track plate results from the Vinca experiment are shown. It can be seen that the backscattered fast flux is about one-third of the incident fast flux and that the energy indicated by the shape of the curve is considerably lower than the energy of the direct neutrons. It seems possible that the high

  5. Neutron measurements with a tissue-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J W [Health Physics Division, Atomic Energy Establishment, Harwell (United Kingdom)

    1962-03-01

    This Appendix 3E of the dosimetry experiment at the R-B reactor describes the apparatus used and presents the obtained results. The phantom used was a 1/4-inch thick polythene container, 60 cm high, of elliptical cross-section, with a major axis of 36 cm and a minor axis of 20 cm. This was filled with an approximately tissue-equivalent liquid. A light but rigid internal framework of Perspex supported a series of small detectors through the phantom. The detectors used in the first high-level run at Vinca, to measure flux above 0.5 MeV, were 0.5-cm wide track plates wrapped in cadmium foil. Each track plate was a sandwich of two Ilford El 50 - {mu} emulsions, with glass backing, separated by a 250-{mu} polythene radiator, and was oriented at an angle of 45 deg to the front surface of the phantom. Under these conditions the response is constant with neutron energy between 0.5 MeV and 8 MeV at 1.26 X 10{sup -3} tracks/neutron to within {+-} 15%. The detectors used in the second high-level run were gold foils (260 mg/cm{sup 2} thick) for determination of the show neutron distribution. Previous experiments with 0.13 MeV, 2.5 MeV, 14 MeV and Po-Be neutrons have shown that the shape of the curve through a phantom obtained from these gold foils is the same as that given by either manganese foils or sodium samples despite the difference in resonance integrals. From the relaxation length of the neutron flux in the phantom, as measured by the track plates, the mean energy of the neutrons with energies greater than 0.5 MeV may be found by comparison with the relaxation lengths obtained by irradiation of the phantom with monoenergetic neutrons. The results of these experiments are given. Track plate results from the Vinca experiment are shown. It can be seen that the backscattered fast flux is about one-third of the incident fast flux and that the energy indicated by the shape of the curve is considerably lower than the energy of the direct neutrons. It seems possible that the

  6. Energy-Efficient Resource Allocation for Phantom Cellular Networks with Imperfect CSI

    KAUST Repository

    Abdelhady, Amr Mohamed Abdelaziz

    2017-03-28

    Multi-tier heterogeneous networks have become an essential constituent for next generation cellular networks. Meanwhile, energy efficiency (EE) has been considered a critical design criterion along with the traditional spectral efficiency (SE) metric. In this context, we study power and spectrum allocation for a two-tier phantom cellular network, The optimization framework includes both EE and SE. We consider densely deployed phantom cellular networks and model the EE optimization problem taking into consideration the inevitable interference in this setup and imperfect channel estimation impairments. To this end, we propose three resource allocation strategies aiming at optimizing this network EE performance metric. Furthermore, we investigate the effect of changing some system parameters on the performance of these strategies, such as phantom cells resource units share, number of deployed phantom cells within a macro cell , number of pilots, and the phantom cells transmission power budget. It is found that increasing the number of pilots will deteriorate the EE performance of the whole setup, while increasing phantom cells transmission power budget will not affect the EE of the whole setup significantly. In addition, we observed that it is always useful to allocate most of the network resource units to the phantom cells tier.

  7. Energy-Efficient Resource Allocation for Phantom Cellular Networks with Imperfect CSI

    KAUST Repository

    Abdelhady, Amr Mohamed Abdelaziz; Amin, Osama; Alouini, Mohamed-Slim

    2017-01-01

    Multi-tier heterogeneous networks have become an essential constituent for next generation cellular networks. Meanwhile, energy efficiency (EE) has been considered a critical design criterion along with the traditional spectral efficiency (SE) metric. In this context, we study power and spectrum allocation for a two-tier phantom cellular network, The optimization framework includes both EE and SE. We consider densely deployed phantom cellular networks and model the EE optimization problem taking into consideration the inevitable interference in this setup and imperfect channel estimation impairments. To this end, we propose three resource allocation strategies aiming at optimizing this network EE performance metric. Furthermore, we investigate the effect of changing some system parameters on the performance of these strategies, such as phantom cells resource units share, number of deployed phantom cells within a macro cell , number of pilots, and the phantom cells transmission power budget. It is found that increasing the number of pilots will deteriorate the EE performance of the whole setup, while increasing phantom cells transmission power budget will not affect the EE of the whole setup significantly. In addition, we observed that it is always useful to allocate most of the network resource units to the phantom cells tier.

  8. Factors That Influence Vaccination Decision-Making by Parents Who Visit an Anthroposophical Child Welfare Center: A Focus Group Study

    Directory of Open Access Journals (Sweden)

    Irene A. Harmsen

    2012-01-01

    Full Text Available In recent years, parents have become more disparaging towards childhood vaccination. One group that is critical about the National Immunization Program (NIP and participates less comprises parents with an anthroposophical worldview. Despite the fact that various studies have identified anthroposophists as critical parents with lower vaccination coverage, no research has been done to explore the beliefs underlying their childhood vaccination decision-making. We conducted a qualitative study using three focus groups ( of parents who visit an anthroposophical child welfare center. Our findings show that participants did not refuse all vaccinations within the Dutch NIP, but mostly refused the Mumps, Measles, and Rubella (MMR vaccination. Vaccination decisions are influenced by participants’ lifestyle, perception of health, beliefs about childhood diseases, perceptions about the risks of diseases, perceptions about vaccine effectiveness and vaccine components, and trust in institutions. Parents indicated that they felt a need for more information. Sufficient references should be provided to sources containing more information about childhood vaccination, especially about the effectiveness of vaccines and vaccine components and the risks, such as possible side effects and benefits of vaccination. This may satisfy parents’ information needs and enable them to make a sufficiently informed choice whether or not to vaccinate their child.

  9. Parental Bonding

    Directory of Open Access Journals (Sweden)

    T. Paul de Cock

    2014-08-01

    Full Text Available Estimating the early parent–child bonding relationship can be valuable in research and practice. Retrospective dimensional measures of parental bonding provide a means for assessing the experience of the early parent–child relationship. However, combinations of dimensional scores may provide information that is not readily captured with a dimensional approach. This study was designed to assess the presence of homogeneous groups in the population with similar profiles on parental bonding dimensions. Using a short version of the Parental Bonding Instrument (PBI, three parental bonding dimensions (care, authoritarianism, and overprotection were used to assess the presence of unobserved groups in the population using latent profile analysis. The class solutions were regressed on 23 covariates (demographics, parental psychopathology, loss events, and childhood contextual factors to assess the validity of the class solution. The results indicated four distinct profiles of parental bonding for fathers as well as mothers. Parental bonding profiles were significantly associated with a broad range of covariates. This person-centered approach to parental bonding has broad utility in future research which takes into account the effect of parent–child bonding, especially with regard to “affectionless control” style parenting.

  10. Reversible induction of phantom auditory sensations through simulated unilateral hearing loss.

    Directory of Open Access Journals (Sweden)

    Roland Schaette

    Full Text Available Tinnitus, a phantom auditory sensation, is associated with hearing loss in most cases, but it is unclear if hearing loss causes tinnitus. Phantom auditory sensations can be induced in normal hearing listeners when they experience severe auditory deprivation such as confinement in an anechoic chamber, which can be regarded as somewhat analogous to a profound bilateral hearing loss. As this condition is relatively uncommon among tinnitus patients, induction of phantom sounds by a lesser degree of auditory deprivation could advance our understanding of the mechanisms of tinnitus. In this study, we therefore investigated the reporting of phantom sounds after continuous use of an earplug. 18 healthy volunteers with normal hearing wore a silicone earplug continuously in one ear for 7 days. The attenuation provided by the earplugs simulated a mild high-frequency hearing loss, mean attenuation increased from 30 dB at 3 and 4 kHz. 14 out of 18 participants reported phantom sounds during earplug use. 11 participants presented with stable phantom sounds on day 7 and underwent tinnitus spectrum characterization with the earplug still in place. The spectra showed that the phantom sounds were perceived predominantly as high-pitched, corresponding to the frequency range most affected by the earplug. In all cases, the auditory phantom disappeared when the earplug was removed, indicating a causal relation between auditory deprivation and phantom sounds. This relation matches the predictions of our computational model of tinnitus development, which proposes a possible mechanism by which a stabilization of neuronal activity through homeostatic plasticity in the central auditory system could lead to the development of a neuronal correlate of tinnitus when auditory nerve activity is reduced due to the earplug.

  11. Alderson-Rando phantom 'voxelization' for use in numerical dosimetry

    International Nuclear Information System (INIS)

    Santos, A.M.; Vieira, J.W.

    2008-01-01

    This paper presents the methodology used for creating a voxel phantom from the tomographic physical Alderson-Rando phantom images (HR) and to develop a computer model formed by exposure of the resulting phantom 'voxelization' of AR coupled to the Monte Carlo code EGS4 plus algorithms to simulate radioactive sources in internal dosimetry

  12. Dosimetric study on head CT scans using adult and newborn phantoms

    International Nuclear Information System (INIS)

    Paiva de O, G. A.; Prata M, A.

    2016-10-01

    Computed tomography is the radiodiagnostic method that most contributes to the dose deposition in population. Therefore, the dose reductions used in these tests are very important, especially for pediatric patients who have a life expectancy greater than the rest of the population. This study purpose to compare the doses generated from newborns compared to adult patients in head computed tomography scans. Two head phantoms in a cylindrical shape made in PMMA were used, one to adult and another to newborn patient dimensions. The pediatric routine scan protocol from a radiological service was used for the computed tomography scans. They were performed in General Electric Computed Tomography scanner, Bright Speed model with 4 channels. The absorbed dose measurements were performed with a pencil chamber placed into both phantoms. The newborn head phantom was developed in order to compare the amount of absorbed dose by the phantoms when it is used the same acquisition protocol. The dose found for newborn phantom was 29.9% higher than the adult phantom. (Author)

  13. Dosimetric study on head CT scans using adult and newborn phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva de O, G. A.; Prata M, A., E-mail: giovanni_paiva@hotmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography is the radiodiagnostic method that most contributes to the dose deposition in population. Therefore, the dose reductions used in these tests are very important, especially for pediatric patients who have a life expectancy greater than the rest of the population. This study purpose to compare the doses generated from newborns compared to adult patients in head computed tomography scans. Two head phantoms in a cylindrical shape made in PMMA were used, one to adult and another to newborn patient dimensions. The pediatric routine scan protocol from a radiological service was used for the computed tomography scans. They were performed in General Electric Computed Tomography scanner, Bright Speed model with 4 channels. The absorbed dose measurements were performed with a pencil chamber placed into both phantoms. The newborn head phantom was developed in order to compare the amount of absorbed dose by the phantoms when it is used the same acquisition protocol. The dose found for newborn phantom was 29.9% higher than the adult phantom. (Author)

  14. Exploring Parental Perspectives on Parent-Child Sexual Communication

    Science.gov (United States)

    Ballard, Sharon M.; Gross, Kevin H.

    2009-01-01

    We examined parental perspectives about parent-child sexual communication through four focus groups conducted with 25 parents of young children. Participant comments fell into six areas: 1) personal experience with sexuality education, 2) current sexuality education efforts, 3) comfort and confidence, 4) content and timing, 5) importance of a…

  15. Deep brain stimulation for phantom limb pain.

    Science.gov (United States)

    Bittar, Richard G; Otero, Sofia; Carter, Helen; Aziz, Tipu Z

    2005-05-01

    Phantom limb pain is an often severe and debilitating phenomenon that has been reported in up to 85% of amputees. Its pathophysiology is poorly understood. Peripheral and spinal mechanisms are thought to play a role in pain modulation in affected individuals; however central mechanisms are also likely to be of importance. The neuromatrix theory postulates a genetically determined representation of body image, which is modified by sensory input to create a neurosignature. Persistence of the neurosignature may be responsible for painless phantom limb sensations, whereas phantom limb pain may be due to abnormal reorganisation within the neuromatrix. This study assessed the clinical outcome of deep brain stimulation of the periventricular grey matter and somatosensory thalamus for the relief of chronic neuropathic pain associated with phantom limb in three patients. These patients were assessed preoperatively and at 3 month intervals postoperatively. Self-rated visual analogue scale pain scores assessed pain intensity, and the McGill Pain Questionnaire assessed the quality of the pain. Quality of life was assessed using the EUROQOL EQ-5D scale. Periventricular gray stimulation alone was optimal in two patients, whilst a combination of periventricular gray and thalamic stimulation produced the greatest degree of relief in one patient. At follow-up (mean 13.3 months) the intensity of pain was reduced by 62% (range 55-70%). In all three patients, the burning component of the pain was completely alleviated. Opiate intake was reduced in the two patients requiring morphine sulphate pre-operatively. Quality of life measures indicated a statistically significant improvement. This data supports the role for deep brain stimulation in patients with phantom limb pain. The medical literature relating to the epidemiology, pathogenesis, and treatment of this clinical entity is reviewed in detail.

  16. Reconstruction of voxel phantoms for skin dosimetry

    International Nuclear Information System (INIS)

    Antunes, Paula Cristina Guimaraes

    2010-01-01

    Radiotherapy is a therapeutic modality that utilizes ionizing radiation for the destruction of neoplastic human cells. One of the requirements for this treatment methodology success lays on the appropriate use of planning systems, which performs, among other information, the patient's dose distribution estimate. Nowadays, transport codes have been providing huge subsidies to these planning systems, once it enables specific and accurate patient organ and tissue dosimetry. The model utilized by these codes to describe the human anatomy in a realistic way is known as voxel phantoms, which are represented by discrete volume elements (voxels) directly associated to tomographic data. Nowadays, voxel phantoms doable of being inserted and processed by the transport code MCNP (Monte Carlo N-Particle) presents a 3-4 mm image resolution; however, such resolution limits some thin body structure discrimination, such as skin. In this context, this work proposes a calculus routine that discriminates this region with thickness and localization in the voxel phantoms similar to the real, leading to an accurate dosimetric skin dose assessment by the MCNP code. Moreover, this methodology consists in manipulating the voxel phantoms volume elements by segmenting and subdividing it in different skin thickness. In addition to validate the skin dose calculated data, a set of experimental evaluations with thermoluminescent dosimeters were performed in an anthropomorphic phantom. Due to significant differences observed on the dose distribution of several skin representations, it was found that is important to discriminate the skin thickness similar to the real. The presented methodology is useful to obtain an accurate skin dosimetric evaluation for several radiotherapy procedures, with particular interest on the electron beam radiotherapy, in which highlights the whole body irradiation therapy (TSET), a procedure under implementation at the Hospital das Clinicas da Faculdade de Medicina da

  17. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    CERN Document Server

    Endo, A; Zankl, M; Bolch, W E; Eckerman, K F; Hertel, N E; Hunt, J G; Pelliccioni, M; Schlattl, H; Menzel, H-G

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.

  18. Skin and cutaneous melanocytic lesion simulation in biomedical optics with multilayered phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Urso, P [Department of Occupational and Environmental Health, Hospital L. Sacco Unit, University of Milan, Via G B Grassi, 74-20157 Milan (Italy); Lualdi, M [Medical Physics Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Via Venezian 1-20133 Milan (Italy); Colombo, A [Medical Physics Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Via Venezian 1-20133 Milan (Italy); Carrara, M [Medical Physics Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Via Venezian 1-20133 Milan (Italy); Tomatis, S [Medical Physics Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Via Venezian 1-20133 Milan (Italy); Marchesini, R [Medical Physics Unit, Istituto Nazionale per lo Studio e la Cura dei Tumori, Via Venezian 1-20133 Milan (Italy)

    2007-05-21

    The complex inner layered structure of skin influences the photon diffusion inside the cutaneous tissues and determines the reflectance spectra formation. Phantoms are very useful tools to understand the biophysical meaning of parameters involved in light propagation through the skin. To simulate the skin reflectance spectrum, we realized a multilayered skin-like phantom and a multilayered skin phantom with a melanoma-like phantom embedded inside. Materials used were Al{sub 2}O{sub 3} particles, melanin of sepia officinalis and a calibrator for haematology systems dispersed in transparent silicon. Components were optically characterized with indirect techniques. Reflectance phantom spectra were compared with average values of in vivo spectra acquired on a sample of 573 voluntary subjects and 132 pigmented lesions. The phantoms' reflectance spectra agreed with those measured in vivo, mimicking the optical behaviour of the human skin. Further, the phantoms were optically stable and easily manageable, and represented a valid resource in spectra formation comprehension, in diagnostic laser applications and simulation model implementation, such as the Monte Carlo code for non-homogeneous media. (note)

  19. Skin and cutaneous melanocytic lesion simulation in biomedical optics with multilayered phantoms

    International Nuclear Information System (INIS)

    Urso, P; Lualdi, M; Colombo, A; Carrara, M; Tomatis, S; Marchesini, R

    2007-01-01

    The complex inner layered structure of skin influences the photon diffusion inside the cutaneous tissues and determines the reflectance spectra formation. Phantoms are very useful tools to understand the biophysical meaning of parameters involved in light propagation through the skin. To simulate the skin reflectance spectrum, we realized a multilayered skin-like phantom and a multilayered skin phantom with a melanoma-like phantom embedded inside. Materials used were Al 2 O 3 particles, melanin of sepia officinalis and a calibrator for haematology systems dispersed in transparent silicon. Components were optically characterized with indirect techniques. Reflectance phantom spectra were compared with average values of in vivo spectra acquired on a sample of 573 voluntary subjects and 132 pigmented lesions. The phantoms' reflectance spectra agreed with those measured in vivo, mimicking the optical behaviour of the human skin. Further, the phantoms were optically stable and easily manageable, and represented a valid resource in spectra formation comprehension, in diagnostic laser applications and simulation model implementation, such as the Monte Carlo code for non-homogeneous media. (note)

  20. Realistic deformable 3D numeric phantom for transcutaneous ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Fernando Mitsuyama; Moraes, Matheus Cardoso; Furuie, Sergio Shiguemi, E-mail: fernando.okara@gmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Engenharia

    2017-01-15

    Introduction: Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods: First, a volume representing the target tissue is loaded. Second, parameter values, such as Young's Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results: The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion: The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes. (author)

  1. Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models

    International Nuclear Information System (INIS)

    Lee, Choonsik; Lodwick, Daniel; Hasenauer, Deanna; Williams, Jonathan L; Lee, Choonik; Bolch, Wesley E

    2007-01-01

    Anthropomorphic computational phantoms are computer models of the human body for use in the evaluation of dose distributions resulting from either internal or external radiation sources. Currently, two classes of computational phantoms have been developed and widely utilized for organ dose assessment: (1) stylized phantoms and (2) voxel phantoms which describe the human anatomy via mathematical surface equations or 3D voxel matrices, respectively. Although stylized phantoms based on mathematical equations can be very flexible in regard to making changes in organ position and geometrical shape, they are limited in their ability to fully capture the anatomic complexities of human internal anatomy. In turn, voxel phantoms have been developed through image-based segmentation and correspondingly provide much better anatomical realism in comparison to simpler stylized phantoms. However, they themselves are limited in defining organs presented in low contrast within either magnetic resonance or computed tomography images-the two major sources in voxel phantom construction. By definition, voxel phantoms are typically constructed via segmentation of transaxial images, and thus while fine anatomic features are seen in this viewing plane, slice-to-slice discontinuities become apparent in viewing the anatomy of voxel phantoms in the sagittal or coronal planes. This study introduces the concept of a hybrid computational newborn phantom that takes full advantage of the best features of both its stylized and voxel counterparts: flexibility in phantom alterations and anatomic realism. Non-uniform rational B-spline (NURBS) surfaces, a mathematical modeling tool traditionally applied to graphical animation studies, was adopted to replace the limited mathematical surface equations of stylized phantoms. A previously developed whole-body voxel phantom of the newborn female was utilized as a realistic anatomical framework for hybrid phantom construction. The construction of a hybrid

  2. Effect of inherent misalignment and head motion in neurological PET/MR with the Philips Ingenuity TF – phantom and patient study

    Energy Technology Data Exchange (ETDEWEB)

    Teuho, Jarmo; Johansson, Jarkko; Saunavaara, Virva; Kemppainen, Nina; Teräs, Mika [Turku PET Centre, Turku University Hospital, Turku (Finland)

    2014-07-29

    The aim of the study was to evaluate the effect of misalignment and head motion on image quantification in PET/MR with a novel brain phantom and a healthy control group. The phantom was imaged at two time points in PET/MR, concurrently with PET and PET/CT. Phantom images were evaluated visually and the relative difference in hemispheric accumulation was calculated. Difference in cortical accumulation in a healthy control group was evaluated from non-attenuation corrected (NAC) and MR attenuation corrected (MRAC) images. Regional ROI mean values from F{sup 18}-FDG ratio images and regional hemispheric asymmetries were calculated. Controls were divided to high and low asymmetry groups. A student’s t-test (p<0.005) for group difference and NAC versus MRAC data was performed. Finally, mean PET-MR registration parameters were measured. Only the first phantom scan exhibited asymmetry in lateral frontal cortex (17%) and temporal cortex (19%). Correcting the misalignment of 2.63mm reduced the asymmetry to less than 5%, to a level seen in PET and PET/CT. A significant asymmetry was found in the temporal and parietal cortex between groups in MRAC data with no significant asymmetry in NAC data. Asymmetries in affected MRAC data in temporal and parietal cortex were 9.4% and 11.7%. NAC data from both groups had asymmetry less than 5% in all regions. Both groups had significant y- and z-translation, while only the asymmetry group had significant z-rotation and x-translation. The shift in x-, y-, or z-direction in both groups was less than 4 mm, with no significant differences. Thus, PET-MRAC misalignment may cause under- and overestimation of attenuation in the lines of response on opposite sides of the cortical regions, resulting to asymmetric difference between the hemispheres. Our findings stress the need for novel QC procedures for PET-MR alignment and suggest confirming the quality of PET-MRAC alignment from PET-NAC images.

  3. Anthropomorphic phantom materials

    International Nuclear Information System (INIS)

    White, D.R.; Constantinou, C.

    1982-01-01

    The need, terminology and history of tissue substitutes are outlined. Radiation properties of real tissues are described and simulation procedures are outlined. Recent tissue substitutes are described and charted, as are calculated radiation classifications. Manufacturing procedures and quality control are presented. Recent phantom studies are reviewed and a discussion recorded. Elemental compositions of the recommended tissue substitutes are charted with elemental composition given for each tissue substitute

  4. Solid water phantom

    International Nuclear Information System (INIS)

    Arguiropulo, M.Y.; Ghilardi Neto, T.; Pela, C.A.; Ghilardi, A.J.P.

    1992-01-01

    A phantom were developed for simulating water, based in plastics. The material was evaluated for different energies, and the measures of relative transmission showed that the transmission and the water were inside of 0,6% for gamma rays. The results of this new material were presented, showing that it could be used in photon beam calibration with energies on radiotherapy range. (C.G.C.)

  5. Effect of Graphite Concentration on Shear-Wave Speed in Gelatin-Based Tissue-Mimicking Phantoms

    Science.gov (United States)

    Anderson, Pamela G.; Rouze, Ned C.; Palmeri, Mark L.

    2011-01-01

    Elasticity-based imaging modalities are becoming popular diagnostic tools in clinical practice. Gelatin-based, tissue mimicking phantoms that contain graphite as the acoustic scattering material are commonly used in testing and validating elasticity-imaging methods to quantify tissue stiffness. The gelatin bloom strength and concentration are used to control phantom stiffness. While it is known that graphite concentration can be modulated to control acoustic attenuation, the impact of graphite concentrationon phantom elasticity has not been characterized in these gelatin phantoms. This work investigates the impact of graphite concentration on phantom shear stiffness as characterized by shear-wave speed measurements using impulsive acoustic-radiation-force excitations. Phantom shear-wave speed increased by 0.83 (m/s)/(dB/(cm MHz)) when increasing the attenuation coefficient slope of the phantom material through increasing graphite concentration. Therefore, gelatin-phantom stiffness can be affected by the conventional ways that attenuation is modulated through graphite concentration in these phantoms. PMID:21710828

  6. Determination of photon conversion factors relating exposure and dose for several extremity phantom designs

    International Nuclear Information System (INIS)

    Roberson, P.L.; Eichner, F.N.; Reece, W.D.

    1986-09-01

    This report presents the results of measurements of dosimetric properties of simple extremity phantoms suitable for use in extremity dosimeter performance testing. Two sizes of phantoms were used in this study. One size represented the forearm or lower leg and the other size represented the finger or toe. For both phantom sizes, measurements were performed on solid plastic phantoms and on phantoms containing simulated bone material to determine the effect of backscattered radiations from the bone on the surface dose. Exposure-to-dose conversion factors (C/sub x/ factors) were determined for photon energies ranging from 16 to 1250 keV (average for 60 Co). The effect of the presence of a phantom was also measured for a 90 Sr/ 90 Y source. Significant differences in the measured C/sub x/ factors were found among the phantoms investigated. The factors for the finger-sized phantoms were uniformly less than for the arm-sized phantoms

  7. External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Kim, Jung In; Park, Jong Min; Park, Yang Kyun; Ye, Sung Joon [Medical Research Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Kun Woo; Cho, Woon Kap [Radiation Research, Korean Institute of Nuclear Safety, Daejeon (Korea, Republic of); Lim, Chun Il [Korea Food and Drug Administration, Seoul (Korea, Republic of)

    2010-11-15

    We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party's American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Most of the beams (74%) were within {+-}2% of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance ({+-}3%), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be {+-}1.5%. The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

  8. Development of a patient-specific two-compartment anthropomorphic breast phantom

    International Nuclear Information System (INIS)

    Prionas, Nicolas D; Burkett, George W; McKenney, Sarah E; Chen, Lin; Boone, John M; Stern, Robin L

    2012-01-01

    The purpose of this paper is to develop a technique for the construction of a two-compartment anthropomorphic breast phantom specific to an individual patient's pendant breast anatomy. Three-dimensional breast images were acquired on a prototype dedicated breast computed tomography (bCT) scanner as part of an ongoing IRB-approved clinical trial of bCT. The images from the breast of a patient were segmented into adipose and glandular tissue regions and divided into 1.59 mm thick breast sections to correspond to the thickness of polyethylene stock. A computer-controlled water-jet cutting machine was used to cut the outer breast edge and the internal regions corresponding to glandular tissue from the polyethylene. The stack of polyethylene breast segments was encased in a thermoplastic ‘skin’ and filled with water. Water-filled spaces modeled glandular tissue structures and the surrounding polyethylene modeled the adipose tissue compartment. Utility of the phantom was demonstrated by inserting 200 µm microcalcifications as well as by measuring point dose deposition during bCT scanning. Affine registration of the original patient images with bCT images of the phantom showed similar tissue distribution. Linear profiles through the registered images demonstrated a mean coefficient of determination (r 2 ) between grayscale profiles of 0.881. The exponent of the power law describing the anatomical noise power spectrum was identical in the coronal images of the patient's breast and the phantom. Microcalcifications were visualized in the phantom at bCT scanning. The real-time air kerma rate was measured during bCT scanning and fluctuated with breast anatomy. On average, point dose deposition was 7.1% greater than the mean glandular dose. A technique to generate a two-compartment anthropomorphic breast phantom from bCT images has been demonstrated. The phantom is the first, to our knowledge, to accurately model the uncompressed pendant breast and the glandular tissue

  9. "Mixed Blessings": Parental Religiousness, Parenting, and Child Adjustment in Global Perspective

    Science.gov (United States)

    Bornstein, Marc H.; Putnick, Diane L.; Lansford, Jennifer E.; Al-Hassan, Suha M.; Bacchini, Dario; Bombi, Anna Silvia; Chang, Lei; Deater-Deckard, Kirby; Di Giunta, Laura; Dodge, Kenneth A.; Malone, Patrick S.; Oburu, Paul; Pastorelli, Concetta; Skinner, Ann T.; Sorbring, Emma; Steinberg, Laurence; Tapanya, Sombat; Tirado, Liliana Maria Uribe; Zelli, Arnaldo; Alampay, Liane Peña

    2017-01-01

    Background: Most studies of the effects of parental religiousness on parenting and child development focus on a particular religion or cultural group, which limits generalizations that can be made about the effects of parental religiousness on family life. Methods: We assessed the associations among parental religiousness, parenting, and…

  10. IMRT delivery verification using a spiral phantom

    International Nuclear Information System (INIS)

    Richardson, Susan L.; Tome, Wolfgang A.; Orton, Nigel P.; McNutt, Todd R.; Paliwal, Bhudatt R.

    2003-01-01

    In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan

  11. Design of a phantom multitrous for a gamma camera quality control

    International Nuclear Information System (INIS)

    Ben Krir, Wafa; Ben Ameur, Narjes

    2009-01-01

    In this study we presented the technique of scintigraphy in its various theoretical and practical aspects. We have also shown the importance the quality control procedure according to international standards, as NEMA. Starting from different phantoms currently used, developed according to standards, we designed our phantom. On the other part, this implementation has helped to highlight our expectations in Concerning the functionality of the phantom. Indeed, these results were very conclusive since they made it possible to make a very fast cost and quality control without ambiguity lower. We have thus proved the very advanced stage of reliability of our phantom.

  12. Coupled oscillators as models of phantom and scalar field cosmologies

    International Nuclear Information System (INIS)

    Faraoni, Valerio

    2004-01-01

    We study a toy model for phantom cosmology recently introduced in the literature and consisting of two oscillators, one of which carries negative kinetic energy. The results are compared with the exact phase space picture obtained for similar dynamical systems describing, respectively, a massive canonical scalar field conformally coupled to the spacetime curvature and a conformally coupled massive phantom. Finally, the dynamical system describing exactly a minimally coupled phantom is studied and compared with the toy model

  13. The design and fabrication of two portal vein flow phantoms by different methods

    Energy Technology Data Exchange (ETDEWEB)

    Yunker, Bryan E., E-mail: bryan.yunker@ucdenver.edu; Lanning, Craig J.; Shandas, Robin; Hunter, Kendall S. [Department of Bioengineering, University of Colorado – Denver/Anschutz, 12700 East 19th Avenue, MS 8607, Aurora, Colorado 80045 (United States); Dodd, Gerald D., E-mail: gerald.dodd@ucdenver.edu; Chang, Samuel; Scherzinger, Ann L. [Department of Radiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop L954, Aurora, Colorado 80045 (United States); Chen, S. James, E-mail: james.chen@ucdenver.edu [Department of Medicine, University of Colorado Denver, Colorado 80045 and Department of Medicine/Cardiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop B132, Aurora, Colorado 80045 (United States); Feng, Yusheng, E-mail: yusheng.feng@utsa.edu [Department of Mechanical Engineering, University of Texas – San Antonio, One UTSA Circle, Mail Stop: AET 2.332, San Antonio, Texas 78249–0670 (United States)

    2014-02-15

    Purpose: This study outlines the design and fabrication techniques for two portal vein flow phantoms. Methods: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three-dimensional portal vein pattern was created from the Visual Human database. The portal vein pattern was used to fabricate two flow phantoms by different methods with identical interior surface geometry using computer aided design software tools and rapid prototyping techniques. One portal flow phantom was fabricated within a solid block of clear silicone for use on a table with Ultrasound or within medical imaging systems such as MRI, CT, PET, or SPECT. The other portal flow phantom was fabricated as a thin walled tubular latex structure for use in water tanks with Ultrasound imaging. Both phantoms were evaluated for usability and durability. Results: Both phantoms were fabricated successfully and passed durability criteria for flow testing in the next project phase. Conclusions: The fabrication methods and materials employed for the study yielded durable portal vein phantoms.

  14. Emotions are a window into one's heart”: a qualitative analysis of parental beliefs about children's emotions across three ethnic groups.

    Science.gov (United States)

    Parker, Alison E; Halberstadt, Amy G; Dunsmore, Julie C; Townley, Greg; Bryant, Alfred; Thompson, Julie A; Beale, Karen S

    2012-09-01

    We conducted a qualitative study to explore parental beliefs about emotions in the family across three cultures (African American, European American, and Lumbee American Indian), using the underutilized yet powerful methodology of focus groups. The main goal of this monograph is to understand parents’ beliefs about the role of emotions in the family and how cultural or ethnic background may influence those beliefs. Based on philosophical traditions and previous research, three dimensions of parental beliefs were predicted: Value of Emotion, Socialization of Emotion, and Controllability of Emotion. We expected new themes to emerge during the focus groups.Twelve focus groups were conducted with 87 parents from the three cultural groups mentioned above. Groups met for two sessions scheduled 2 weeks apart. Focus group discussions were led by same-ethnicity moderators. Aninductive analysis was conducted; key themes and subthemes were identified.All three theoretically derived dimensions were well represented in each focus group. Cultural similarities in themes within these dimensions included children’s appropriate expression of negative emotions, role of emotion in the home, children’s capacity for controlling emotions, and parents’ role in socialization of emotion. Cultural variations included concern about parents’ expression of negative emotion, children’s modulation of positive emotion, the role emotions play in behavior, and choice in emotional experience. Two new dimensions also emerged: Relational Nature of Emotions and Changeability of Emotions. Cultural similarities in themes within these dimensions included emphasis on emotional connections with children, emotional contagion in families, developmental change in children’s emotions, and intergenerational change in emotion socialization. Cultural variation included discussion of emotions as guides for action and children’s emotional privacy. Dimensions and the themes and subthemes within them

  15. Effect of Group Parent Management Traning on Behavioral Disorders of Children with Attention Deficit-Hyoeractivity Disorder

    Directory of Open Access Journals (Sweden)

    Parsa Houshvar

    2009-10-01

    Conclusion: Group parent management training is significantly effective in decreasing behavioral disorders and anxiety status of children with attention deficit hyperactivity disorder and this psychosocial intervention could be used as an effective complementary method beside medication and occupational therapy programs.

  16. Pediatric phantoms for use in dosimetric calculations

    International Nuclear Information System (INIS)

    Shoup, R.L.; Hwang, J.L.; Poston, J.W.; Warner, G.G.

    1976-01-01

    Estimating absorbed doses to children from external and internal radiation sources has become important to the nuclear industry and pediatric nuclear medicine. The Medical Physics and Internal Dosimetry Section at ORNL has recently completed the design of mathematical representations of children of ages newborn, 1 year, and 5 years old. These mathematical representations will be referred to as pediatric phantoms. Using these phantoms, relevant energy deposition data have been developed which establish a meaningful model for use in estimating radiation dose to children

  17. SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

    International Nuclear Information System (INIS)

    Myronakis, M; Cai, W; Dhou, S; Cifter, F; Lewis, J; Hurwitz, M

    2015-01-01

    Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc

  18. SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

    Energy Technology Data Exchange (ETDEWEB)

    Myronakis, M; Cai, W; Dhou, S; Cifter, F; Lewis, J [Brigham and Women’s Hospital, Boston, MA (United States); Hurwitz, M [Newton, MA (United States)

    2015-06-15

    Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc.

  19. SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, D; Liu, Y [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.

  20. Phantom's construction for dose measurement in brachytherapy

    International Nuclear Information System (INIS)

    Tri Harjanto; Hidayat Joko Puspito; Joko Triyanto

    2009-01-01

    In nuclear medicine, dose rate validation is the key for a successful process in therapy and diagnose of any deases. Therefore, the brachytherapy equipment being designed and constructed is to be validated its dose rate received by the radiated object. A phantom for such validation purpose is designed and constructed as a correct as if on site geometrical position of sources. The design of phantom consists of seven layers of flexi glass plates: 10 mm thick, 105 mm wide, and 280 mm length. All the plates are to be holed according to the size of the applicator to be used. Every surface of the flexi glass layers is grooved 1 mm wide, 1 mm depth, and 10 mm distance between the groove. The applicator inside the phantom is positioned at a certain reference for measurement. Every TLD installed has a fix position toward the reference coordinate and has an index number. By this system of phantom, the isodose system can be plotted. (author)

  1. Gravitational Quasinormal Modes of Regular Phantom Black Hole

    Directory of Open Access Journals (Sweden)

    Jin Li

    2017-01-01

    Full Text Available We investigate the gravitational quasinormal modes (QNMs for a type of regular black hole (BH known as phantom BH, which is a static self-gravitating solution of a minimally coupled phantom scalar field with a potential. The studies are carried out for three different spacetimes: asymptotically flat, de Sitter (dS, and anti-de Sitter (AdS. In order to consider the standard odd parity and even parity of gravitational perturbations, the corresponding master equations are derived. The QNMs are discussed by evaluating the temporal evolution of the perturbation field which, in turn, provides direct information on the stability of BH spacetime. It is found that in asymptotically flat, dS, and AdS spacetimes the gravitational perturbations have similar characteristics for both odd and even parities. The decay rate of perturbation is strongly dependent on the scale parameter b, which measures the coupling strength between phantom scalar field and the gravity. Furthermore, through the analysis of Hawking radiation, it is shown that the thermodynamics of such regular phantom BH is also influenced by b. The obtained results might shed some light on the quantum interpretation of QNM perturbation.

  2. A suitability study of the fission product phantom and the bottle manikin absorption phantom for calibration of in vivo bioassay equipment for the DOELAP accreditation testing program

    International Nuclear Information System (INIS)

    Olsen, P.C.; Lynch, T.P.

    1991-08-01

    Pacific Northwest laboratory (PNL) conducted an intercomparison study of the Fission Product phantom and the bottle manikin absorption (BOMAB) phantom for the US Department of Energy (DOE) to determine the consistency of calibration response of the two phantoms and their suitability for certification and use under a planned bioassay laboratory accreditation program. The study was initiated to determine calibration factors for both types of phantoms and to evaluate the suitability of their use in DOE Laboratory Accreditation Program (DOELAP) round-robin testing. The BOMAB was found to be more appropriate for the DOELAP testing program. 9 refs., 9 figs., 9 tabs

  3. Development of realistic chest phantom for calibration of in-vivo plutonium counting facilities

    International Nuclear Information System (INIS)

    Shirotani, Takashi

    1987-06-01

    We have developed realistic chest phantom with removable model organs. The phantom is a torso and is terminated just above the femoral region. Tissue equivalent materials used in the phantom have been made of polyurethane with different amounts of ester of phosphoric acid, in order to simulate human soft tissues such as muscle, muscle-adipose mixtures and cartilage. Lung simulant has been made of foamed polyurethane. Capsulized small sources can be inserted into the holes, drilled in each sliced section of the model organ. Counting efficiencies, obtained with a pair of 12 cm diameter phoswich detectors set above the phantom chest, are 0.195 cpm/nCi for Pu-239 and 44.07 cpm/nCi for Am-241, respectively. The results agree well with efficiencies obtained with IAEA-Phantom. We conclude that the phantom can be used as a standard phantom for the calibration of Pu chest counting equipment. (author)

  4. Reflexology treatment for patients with lower limb amputations and phantom limb pain--an exploratory pilot study.

    Science.gov (United States)

    Brown, Christine Ann; Lido, Catherine

    2008-05-01

    intensity and duration of phantom limb pain, in this group of clients. The follow-up questionnaire revealed that there was a maintained improvement in the intensity of phantom limb pain the patients experienced and that the majority still self-treated.

  5. Radiological response and dosimetry in physical phantom of head and neck for 3D conformational radiotherapy

    International Nuclear Information System (INIS)

    Thompson, Larissa

    2013-01-01

    Phantoms are tools for simulation of organs and tissues of the human body in radiology and radiotherapy. This thesis describes the development, validation and, most importantly, the use of a physical head and neck phantom in radiology and radiotherapy, with the purpose of evaluating dose distribution using Gafchromic EBT2 film in 15 MV 3D conformal radiotherapy. The work was divided in two stages, (1) development of new equivalent tissues and improvement of the physical phantom, and (2) use of the physical phantom in experimental dosimetry studies. In phase (1) parameters such as mass density, chemical composition of tissues, anatomical and biometric measurements were considered, as well as aspects of imaging by computed tomography (CT) and radiological response representation in Hounsfield Units (HU), which were compared with human data. Radiological experiments of in-phantom simulated brain pathologies were also conducted. All those results matched human-sourced data, therefore the physical phantom is a suitable simulator that may be used to enhance radiological protocols and education in medical imaging. The main objective in phase (2) was to evaluate the spatial dose distribution in a brain tumor simulator inserted inside the head and neck phantom developed by the Ionizing Radiation Research Group (NRI), exposed to 15 MV 3D conformal radiotherapy, for internal dose assessment. Radiation planning was based on CT images of the physical phantom with a brain tumor simulator made with equivalent material. The treatment planning system (TPS), CAT3D software, used CT images and prescribed a dose of 200 cGy, distributed in three fields of radiation, in a T-shaped pattern. The TPS covered the planning treatment volume (PTV) with 97% of the prescribed dose. A solid water phantom and radiochromic Gafchromic EBT2 film were used for calibration procedures, generating a dose response curve as a function of optical density (OD). After calibration and irradiation, the film

  6. Parents' experience of undertaking an intensive cognitive orientation to daily occupational performance (CO-OP) group for children with cerebral palsy.

    Science.gov (United States)

    Jackman, Michelle; Novak, Iona; Lannin, Natasha; Froude, Elspeth

    2017-05-01

    The purpose of this study was to explore the experience of parents of children with cerebral palsy (CP) who participated in an intensive cognitive orientation to daily occupational performance (CO-OP) group program addressing child chosen goals. Participants were six parents of children with CP who participated in a CO-OP upper limb task-specific training program. Parents participated in semi-structured interviews conducted via phone. A grounded theory approach was used. Interviews were transcribed verbatim and coded to identify categories and overarching themes of the parent experience of CO-OP. The theory of CO-OP for children with CP was one of offering a unique and motivating learning experience for both the child and the parent, differing from other therapeutic approaches that families had previously been involved in. Five categories were identified: the unique benefits of CO-OP; the importance of intensity; the child's motivation; challenging the parent role; and the benefits and challenges of therapy within a group context. Parents felt that CO-OP was a worthwhile intervention that leads to achievement of goals involving upper limb function and had the capacity to be transferred to future goals. Intensity of therapy and a child's motivation were identified as important factors in improvements. Further studies using quantitative research methods are warranted to investigate the benefits of CO-OP for children with neurological conditions. Implications for rehabilitation The cognitive orientation to daily occupational performance (CO-OP) is a promising upper limb cognitive motor training intervention for children with cerebral palsy. In a small sample, parents perceived that CO-OP leads to achievement of upper limb goals. Intensity of therapy, the child's motivation and the parents' ability to "step-back" were identified as important to the success of CO-OP.

  7. Cosmological perturbations in transient phantom inflation scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Richarte, Martin G. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil); Universidad de Buenos Aires, Ciudad Universitaria 1428, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina); Kremer, Gilberto M. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil)

    2017-01-15

    We present a model of inflation where the inflaton is accommodated as a phantom field which exhibits an initial transient pole behavior and then decays into a quintessence field which is responsible for a radiation era. We must stress that the present unified model only deals with a single field and that the transition between the two eras is achieved in a smooth way, so the model does not suffer from the eternal inflation issue. We explore the conditions for the crossing of the phantom divide line within the inflationary era along with the structural stability of several critical points. We study the behavior of the phantom field within the slow-climb approximation along with the necessary conditions to have sufficient inflation. We also examine the model at the level of classical perturbations within the Newtonian gauge and determine the behavior of the gravitational potential, contrast density and perturbed field near the inflation stage and the subsequent radiation era. (orig.)

  8. Development and application of a set of mesh-based and age-dependent Chinese family phantoms for radiation protection dosimetry: Preliminary Data for external photon beams

    Science.gov (United States)

    Pi, Yifei; Zhang, Lian; Huo, Wanli; Feng, Mang; Chen, Zhi; Xu, X. George

    2017-09-01

    A group of mesh-based and age-dependent family phantoms for Chinese populations were developed in this study. We implemented a method for deforming original RPI-AM and RPI-AF models into phantoms of different ages: 5, 10 ,15 and adult. More than 120 organs for each model were processed to match with the values of the Chinese reference parameters within 0.5%. All of these phantoms were then converted to voxel format for Monte Carlo simulations. Dose coefficients for adult models were counted to compare with those of RPI-AM and RPI-AF. The results show that there are significant differences between absorbed doses of RPI phantoms and these of our adult phantoms at low energies. Comparisons for the dose coefficients among different ages and genders were also made. it was found that teenagers receive more radiation doses than adults under the same irradiation condition. This set of phantoms can be utilized to estimate dosimetry for Chinese population for radiation protection, medical imaging, and radiotherapy.

  9. Characterisation of an anthropomorphic chest phantom for dose measurements in radiology beams

    Science.gov (United States)

    Henriques, L. M. S.; Cerqueira, R. A. D.; Santos, W. S.; Pereira, A. J. S.; Rodrigues, T. M. A.; Carvalho Júnior, A. B.; Maia, A. F.

    2014-02-01

    The objective of this study was to characterise an anthropomorphic chest phantom for dosimetric measurements of conventional radiology beams. This phantom was developed by a previous research project at the Federal University of Sergipe for image quality control tests. As the phantom consists of tissue-equivalent material, it is possible to characterise it for dosimetric studies. For comparison, a geometric chest phantom, consisting of PMMA (polymethylmethacrylate) with dimensions of 30×30×15 cm³ was used. Measurements of incident air kerma (Ki) and entrance surface dose (ESD) were performed using ionisation chambers. From the results, backscatter factors (BSFs) of the two phantoms were determined and compared with values estimated by CALDose_X software, based on a Monte Carlo simulation. For the technical parameters evaluated in this study, the ESD and BSF values obtained experimentally showed a good similarity between the two phantoms, with minimum and maximum difference of 0.2% and 7.0%, respectively, and showed good agreement with the results published in the literature. Organ doses and effective doses for the anthropomorphic phantom were also estimated by the determination of conversion coefficients (CCs) using the visual Monte Carlo (VMC) code. Therefore, the results of this study prove that the anthropomorphic thorax phantom proposed is a good tool to use in dosimetry and can be used for risk evaluation of X-ray diagnostic procedures.

  10. A Randomised Group Comparison Controlled Trial of "Preschoolers with Autism": A Parent Education and Skills Training Intervention for Young Children with Autistic Disorder

    Science.gov (United States)

    Tonge, Bruce; Brereton, Avril; Kiomall, Melissa; Mackinnon, Andrew; Rinehart, Nicole J.

    2014-01-01

    Aim: To determine the effect of parent education on adaptive behaviour, autism symptoms and cognitive/language skills of young children with autistic disorder. Method: A randomised group comparison design involving a parent education and counselling intervention and a parent education and behaviour management intervention to control for parent…

  11. Creating 3D gelatin phantoms for experimental evaluation in biomedicine

    Directory of Open Access Journals (Sweden)

    Stein Nils

    2015-09-01

    Full Text Available We describe and evaluate a setup to create gelatin phantoms by robotic 3D printing. Key aspects are the large workspace, reproducibility and resolution of the created phantoms. Given its soft tissue nature, the gelatin is kept fluid during inside the system and we present parameters for additive printing of homogeneous, solid objects. The results indicate that 3D printing of gelatin can be an alternative for quickly creating larger soft tissue phantoms without the need for casting a mold.

  12. Development of PIMAL: Mathematical Phantom with Moving Arms and Legs

    Energy Technology Data Exchange (ETDEWEB)

    Akkurt, Hatice [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eckerman, Keith F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2007-05-01

    The computational model of the human anatomy (phantom) has gone through many revisions since its initial development in the 1970s. The computational phantom model currently used by the Nuclear Regulatory Commission (NRC) is based on a model published in 1974. Hence, the phantom model used by the NRC staff was missing some organs (e.g., neck, esophagus) and tissues. Further, locations of some organs were inappropriate (e.g., thyroid).Moreover, all the computational phantoms were assumed to be in the vertical-upright position. However, many occupational radiation exposures occur with the worker in other positions. In the first phase of this work, updates on the computational phantom models were reviewed and a revised phantom model, which includes the updates for the relevant organs and compositions, was identified. This revised model was adopted as the starting point for this development work, and hence a series of radiation transport computations, using the Monte Carlo code MCNP5, was performed. The computational results were compared against values reported by the International Commission on Radiation Protection (ICRP) in Publication 74. For some of the organs (e.g., thyroid), there were discrepancies between the computed values and the results reported in ICRP-74. The reasons behind these discrepancies have been investigated and are discussed in this report.Additionally, sensitivity computations were performed to determine the sensitivity of the organ doses for certain parameters, including composition and cross sections used in the simulations. To assess the dose for more realistic exposure configurations, the phantom model was revised to enable flexible positioning of the arms and legs. Furthermore, to reduce the user time for analyses, a graphical user interface (GUI) was developed. The GUI can be used to visualize the positioning of the arms and legs as desired posture is achieved to generate the input file, invoke the computations, and extract the organ dose

  13. Ultrasonic measurements of chest wall thickness and realistic chest phantom for calibration of Pu lung counting facilities

    International Nuclear Information System (INIS)

    Shirotani, Takashi

    1990-01-01

    There are four important problems for the measurements of chest wall thickness using ultrasonic device: (1) selection of optimum position of transducer and the number of measured points on the chest covered with detector, (2) estimation of adipose-to-muscle ratio in the chest wall, especially for dispersed adipose like 'marbled beef', (3) determination of regression equations for the prediction of chest wall thickness, derived from groups of different body shape, i.e. corpulent and lean, and (4) estimation of effective chest wall thickness involved self-absorption layer of lung tissue, which changes with distribution of activity in the lungs. This quantity can not be measured with ultrasonic device. Realistic chest phantom was developed. The phantom contains removable model organs (lungs, liver, kidneys and heart), model trachea and artificial rib cage, and also includes chest plates that can be placed over the chest to simulate wide range adipose-to-muscle ratio in the chest wall. Various soft tissue substitutes were made of polyurethane with different concentrations of additive, and the rib cage were made of epoxy resin with calcium carbonate. The experimental data have shown that the phantom can be used as a standard phantom for the calibration. (author)

  14. An evaluation of a behavioural parenting intervention for parents of gifted children.

    Science.gov (United States)

    Morawska, Alina; Sanders, Matthew

    2009-06-01

    Parents of gifted children identify a need for tailored parenting support, and gifted children have unique requirements and vulnerabilities. The aim of this study was to assess the efficacy of a tailored behavioural parenting intervention, for enhancing the parenting skills of parents of gifted children and to assess the effect of these changes on the behavioural and emotional adjustment of their gifted child. A randomised controlled trial of tailored Group Triple P - Positive Parenting Program was conducted with 75 parents of children identified as gifted. Results indicated significant intervention effects for the number and frequency of parent reported child behaviour problems, as well as hyperactivity in the intervention group, relative to a waitlist control. Parents also reported significant improvements in their own parenting style, including less permissiveness, harshness, and verbosity when disciplining their child. No intervention effects were evident for teacher reports, except for a trend in relation to hyperactivity. This study demonstrated that a tailored behavioural parenting intervention is effective and acceptable for parents of gifted children, and thus has clinical implications for the delivery of parenting interventions for this population.

  15. MCNPX simulation of proton dose distribution in homogeneous and CT phantoms

    International Nuclear Information System (INIS)

    Lee, C.C.; Lee, Y.J.; Tung, C.J.; Cheng, H.W.; Chao, T.C.

    2014-01-01

    A dose simulation system was constructed based on the MCNPX Monte Carlo package to simulate proton dose distribution in homogeneous and CT phantoms. Conversion from Hounsfield unit of a patient CT image set to material information necessary for Monte Carlo simulation is based on Schneider's approach. In order to validate this simulation system, inter-comparison of depth dose distributions among those obtained from the MCNPX, GEANT4 and FLUKA codes for a 160 MeV monoenergetic proton beam incident normally on the surface of a homogeneous water phantom was performed. For dose validation within the CT phantom, direct comparison with measurement is infeasible. Instead, this study took the approach to indirectly compare the 50% ranges (R 50% ) along the central axis by our system to the NIST CSDA ranges for beams with 160 and 115 MeV energies. Comparison result within the homogeneous phantom shows good agreement. Differences of simulated R 50% among the three codes are less than 1 mm. For results within the CT phantom, the MCNPX simulated water equivalent R eq,50% are compatible with the CSDA water equivalent ranges from the NIST database with differences of 0.7 and 4.1 mm for 160 and 115 MeV beams, respectively. - Highlights: ► Proton dose simulation based on the MCNPX 2.6.0 in homogeneous and CT phantoms. ► CT number (HU) conversion to electron density based on Schneider's approach. ► Good agreement among MCNPX, GEANT4 and FLUKA codes in a homogeneous water phantom. ► Water equivalent R 50 in CT phantoms are compatible to those of NIST database

  16. ICRU activity in the field of phantoms in diagnostic radiology

    International Nuclear Information System (INIS)

    Wambersie, A.; White, D.R.

    1992-01-01

    The ICRU Report on 'Phantoms and Computational Models in Radiation Therapy, Diagnosis and Protection' is presented. The Report contains a major section on human anatomy, from fetus to adult with the variations due to ethnic origin. Tolerance levels for the phantoms (composition, dimensions) are proposed and quality assurance programs are outlined. The report contains extensive appendices: human anatomical data and full specification of over 80 phantoms and computational models. ICRU Report 46 on 'Photon, electron, proton and neutron interaction data for body tissues' is closely related to the field of phantoms. It is a logical continuation on ICRU Report 44 (1989) on 'Tissue substitutes in radiation dosimetry and measurements' and contains the interaction data for more than 100 tissues, from fetal to adult, including some diseased tissues. (author)

  17. A resistive mesh phantom for assessing the performance of EIT systems.

    Science.gov (United States)

    Gagnon, Hervé; Cousineau, Martin; Adler, Andy; Hartinger, Alzbeta E

    2010-09-01

    Assessing the performance of electrical impedance tomography (EIT) systems usually requires a phantom for validation, calibration, or comparison purposes. This paper describes a resistive mesh phantom to assess the performance of EIT systems while taking into account cabling stray effects similar to in vivo conditions. This phantom is built with 340 precision resistors on a printed circuit board representing a 2-D circular homogeneous medium. It also integrates equivalent electrical models of the Ag/AgCl electrode impedances. The parameters of the electrode models were fitted from impedance curves measured with an impedance analyzer. The technique used to build the phantom is general and applicable to phantoms of arbitrary shape and conductivity distribution. We describe three performance indicators that can be measured with our phantom for every measurement of an EIT data frame: SNR, accuracy, and modeling accuracy. These performance indicators were evaluated on our EIT system under different frame rates and applied current intensities. The performance indicators are dependent on frame rate, operating frequency, applied current intensity, measurement strategy, and intermodulation distortion when performing simultaneous measurements at several frequencies. These parameter values should, therefore, always be specified when reporting performance indicators to better appreciate their significance.

  18. Parent Involvement Intervention in Developing Weight Management Skills for both Parents and Overweight/Obese Children.

    Science.gov (United States)

    Kim, Hee Soon; Park, Jiyoung; Park, Kye-Yeong; Lee, Myung-Nam; Ham, Ok Kyung

    2016-03-01

    The purpose of the study was to evaluate a parent involvement intervention for childhood obesity intended to increase parents' skills in managing children's weight-related behavior and to improve child-parent relationships. Many studies reported on parental influence on childhood obesity, emphasizing parent involvement in prevention and management of childhood obesity. A randomized controlled trial was conducted. Forty-two parents of overweight/obese children were recruited from four cities and randomized to the experimental group or control group. The parental intervention was provided only to parents in the experimental group and consisted of weekly newsletters and text messages for a period of 5 weeks. Exercise classes and nutrition education were provided to all children. Lifestyle Behaviour Checklist and the Child-Parent Relationship Scale (CPRS) were used for measurement of parent outcome. For the child outcome, dietary self-efficacy, exercise frequency, and body mass index were measured. A mixed-design analysis of variance was performed with city location entered as a random effect. After the intervention, CPRS of parents and dietary self-efficacy of children showed an increase in the experimental group (p parents and dietary self-efficacy of children (p parent involvement intervention in promoting child-parent relationship and dietary self-efficacy of children. However, a 5-week parent involvement intervention was not sufficient to produce significant changes in children's body mass index. Further research is needed to investigate effects of parent involvement intervention with long-term evaluation. Copyright © 2016. Published by Elsevier B.V.

  19. Parental self-confidence, parenting styles, and corporal punishment in families of ADHD children in Iran.

    Science.gov (United States)

    Alizadeh, Hamid; Applequist, Kimberly F; Coolidge, Frederick L

    2007-05-01

    This study examines the relationship between parental self-confidence, warmth, and involvement, and corporal punishment in families of children with attention deficit/hyperactivity disorder (ADHD). The diagnosis of ADHD was established through clinical interviews with the parents, children, and teachers, according the criteria in DSM-IV-TR. This diagnosis was also established by having the parents complete the Conners' Parent Rating Scale, and the teachers complete the Conners' Teacher Rating Scale. Two groups of Iranian parents, one group with children who have ADHD (N=130) and a control group (N=120), completed questionnaires measuring parental self-confidence and parenting styles. Parents of children with ADHD were found to have lower self-confidence and less warmth and involvement with their children, and used corporal punishment significantly more than the parents of control children. The study provides strong evidence that children with ADHD are at considerable risk of abuse by their parents. Rather than focusing only on the child's ADHD, treatment may also need to address the parents' functioning.

  20. "Emotions Are a Window into One's Heart": A Qualitative Analysis of Parental Beliefs about Children's Emotions across Three Ethnic Groups

    Science.gov (United States)

    Parker, Alison E.; Halberstadt, Amy G.; Dunsmore, Julie C.; Townley, Greg; Bryant, Alfred, Jr.; Thompson, Julie A.; Beale, Karen S.

    2012-01-01

    We conducted a qualitative study to explore parental beliefs about emotions in the family across three cultures (African American, European American, and Lumbee American Indian), using the underutilized yet powerful methodology of focus groups. The main goal of this monograph is to understand parents' beliefs about the role of emotions in the…

  1. Group Motivation in a Nutrition Project for Pregnant and Parenting Teens and Their Spouses by Use of an Incentive Plan.

    Science.gov (United States)

    Collins, Gloria

    A child care agency located in the southeastern United States serving homeless youth up to the age of 21 years provided pregnant and parenting teenagers with shelter and support services and provided individual and group counseling sessions focusing on health and nutrition, parenting and child care, sexuality and pregnancy, family support services…

  2. Atypical Odontalgia (Phantom Tooth Pain)

    Science.gov (United States)

    ... atypical facial pain, phantom tooth pain, or neuropathic orofacial pain, is characterized by chronic pain in a tooth ... such as a specialist in oral medicine or orofacial pain. The information contained in this monograph is for ...

  3. Anisotropic Bianchi-I universe with phantom field and cosmological ...

    Indian Academy of Sciences (India)

    India. *Corresponding author. E-mail: bcpaul@iucaa.ernet.in. MS received 23 May ... We study an anisotropic Bianchi-I universe in the presence of a phantom ... The phantom cosmology has been analysed adopting phase space analysis ... the second part we study the critical points corresponding to the set of autonomous.

  4. An experience of group work with parents of children and adolescents with gender identity disorder.

    Science.gov (United States)

    Di Ceglie, Domenico; Thümmel, Elizabeth Coates

    2006-07-01

    This article gives an account of an experience of group work with parents and carers who had children or adolescents with gender identity disorder (GID). The history of this intervention within the context of a service for children with gender identity problems is outlined. The limited literature on the subject is reviewed. Group meetings were held monthly for 6 months, facilitated by two therapists (the authors). Selection criteria for group participants, the aims of the group and the methodology for achieving those aims are described. Some information about the group's composition is provided. The structure and content of the group sessions are outlined together with details of some group interactions. Finally, we present the results of an evaluation of the intervention through feedback questionnaires and discuss the value for the children and young people of running such groups.

  5. Parenting Stress in Parents of Infants With Congenital Heart Disease and Parents of Healthy Infants: The First Year of Life.

    Science.gov (United States)

    Golfenshtein, Nadya; Hanlon, Alexandra L; Deatrick, Janet A; Medoff-Cooper, Barbara

    2017-12-01

    While we know that the parents of infants with congenital heart disease (CHD), the most prevalent group of congenital anomalies, experience increased parenting stress, the stress levels throughout infancy have yet to be studied. Stress experienced by parents beyond the normative stress of parenting can interfere with parenting processes, and bear adverse family outcomes. This prospective cohort study was conducted to describe and compare parenting stress levels during infancy between parents of infants with complex CHD and parents of healthy infants. The Parenting Stress Index-Long Form was distributed to parents of infants with complex CHD and parents of healthy infants (N = 129). T-tests were used to compare stress between groups at 3, 6, 9, and 12 months of age. Parents of infants with complex CHD had higher parenting stress than parents of healthy infants on multiple subscales on the Child and Parent Domains, at 3 months of age. The stress remained higher on the demandingness subscale throughout infancy. Parents of CHD infants also demonstrated significantly higher stress scores on the life stress subscale at 12 months of age. Findings highlight stressful periods related to parenting infants with CHD, which may increase existing psycho-social risk for parents of infants with CHD. Early family intervention may promote parental adaptation to the illness, and help establishing healthy parenting practices.

  6. Children with Sickle-Cell Anemia: Parental Relations, Parent-Child Relations, and Child Behavior.

    Science.gov (United States)

    Evans, Robert C.; And Others

    1988-01-01

    Investigated the influence of a child with sickle-cell anemia on parental affiliation, parent-child relationships, and parents' perception of their child's behavior. In the sickle-cell group, parents' interpersonal relationship suffered; parent-child relationship and child behavior correlated significantly; and single-parent families estimated…

  7. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  8. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  9. A biomimetic tumor tissue phantom for validating diffusion-weighted MRI measurements.

    Science.gov (United States)

    McHugh, Damien J; Zhou, Feng-Lei; Wimpenny, Ian; Poologasundarampillai, Gowsihan; Naish, Josephine H; Hubbard Cristinacce, Penny L; Parker, Geoffrey J M

    2018-07-01

    To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion-weighted (DW) MRI measurements. Coaxial-electrospraying was used to generate micron-sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW-MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron-CT as well as SEM and MR scans. ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm 2 /ms (Δ = 12 ms) and 1.20 ± 0.05 µm 2 /ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom. A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW-MRI-derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147-158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is

  10. A set of 4D pediatric XCAT reference phantoms for multimodality research

    International Nuclear Information System (INIS)

    Norris, Hannah; Zhang, Yakun; Bond, Jason; Sturgeon, Gregory M.; Samei, E.; Segars, W. P.; Minhas, Anum; Frush, D.; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.

    2014-01-01

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models

  11. A set of 4D pediatric XCAT reference phantoms for multimodality research

    Energy Technology Data Exchange (ETDEWEB)

    Norris, Hannah, E-mail: Hannah.norris@duke.edu; Zhang, Yakun; Bond, Jason; Sturgeon, Gregory M.; Samei, E.; Segars, W. P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Minhas, Anum; Frush, D. [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I. [Center for Imaging Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2014-03-15

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models

  12. Comparison of the ANSI, RSD, KKH, and BRMD thyroid-neck phantoms for 125I thyroid monitoring.

    Science.gov (United States)

    Kramer, G H; Olender, G; Vlahovich, S; Hauck, B M; Meyerhof, D P

    1996-03-01

    The Human Monitoring Laboratory, which acts as the Canadian National Calibration Reference Centre for In Vivo Monitoring, has determined the performance characteristics of four thyroid phantoms for 125I thyroid monitoring. The phantoms were a phantom built to the specifications of the American National Standards Institute Standard N44.3; the phantom available from Radiology Support Devices; the phantom available from Kyoto Kagaku Hyohon; the phantom manufactured by the Human Monitoring Laboratory and known as the BRMD phantom. The counting efficiencies of the phantoms for 125I were measured at different phantom-to-detector distances. The anthropomorphic characteristics of the phantoms have been compared with the average man parameters. It was concluded that the BRMD, American National Standards Institute, and Radiology Support Devices phantoms have the same performance characteristics when the neck-to-detector distances are greater than 12 cm and all phantoms are essentially equivalent at 30 cm or more. The Kyoto Kagaku Hyohon phantom showed lower counting efficiencies at phantom-to-detector distances less than 30 cm. This was attributed to the design of the phantom. This study has also shown that the phantom need not be highly anthropomorphic provided the calibration is not performed at short neck-detector distances. Indeed, it might be possible to use t simple point source of 125I placed behind a 1.5 cm block of lucite at neck detector distances of 12 cm or more.

  13. Design and evaluation of corn starch-bonded Rhizophora spp. particleboard phantoms for SPECT/CT imaging

    Science.gov (United States)

    Hamid, Puteri Nor Khatijah Abd; Yusof, Mohd Fahmi Mohd; Aziz Tajuddin, Abd; Hashim, Rokiah; Zainon, Rafidah

    2018-01-01

    The aim of this study was to design and evaluate of corn starch-bonded Rhizophora spp. particleboards as phantom for SPECT/CT imaging. The phantom was designed according to the Jaszczak phantom commonly used in SPECT imaging with dimension of 22 cm diameter and 18 cm length. Six inserts with different diameter were made for insertion of vials filled with 1.6 µCi/ml of 99mTc unsealed source. The particleboard phantom was scanned using SPECT/CT imaging protocol. The contrast of each vial for particleboards phantom were calculated based on the ratio of counts in radionuclide volume and phantom background and compared to Perspex® and water phantom. The results showed that contrast values for each vial in particleboard phantomis near to 1.0 and in good agreement with Perspex® and water phantoms as common phantom materials for SPECT/CT. The paired sample t-test result showed no significant difference of contrast values between images in particleboard phantoms and that in water. The overall results showed the potential of corn starch-bonded Rhizophora spp. as phantom for quality control and dosimetry works in SPECT/CT imaging.

  14. SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y [University of Kansas Hospital, Kansas City, KS (United States); Fullerton, G; Goins, B [University of Texas Health Science Center at San Antonio, San Antonio, TX (United States)

    2015-06-15

    Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement

  15. A paper sheet phantom for scintigraphic planar imaging. Usefulness of pouch-laminated paper source

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Teraoka, Satomi; Murakami, Tomonori; Kojima, Akihiro; Matsumoto, Masanori

    2007-01-01

    In order to perform experimental measurements for evaluation of imaging device's performance, data acquisition technique, and clinical images on scintigraphic imaging, many kinds of phantoms are employed. However, since these materials are acrylic and plastic, the thickness and quality of those materials cause attenuation and scatter in itself. We developed a paper sheet phantom sealed with a pouch laminator, which can be a true radioactive source in air. In this study, the paper sheet phantom was compared to the acrylic liver phantom, with the thickness of 2 cm, which is commercially available. The results showed that although some scatter counts were contained within the image of the acrylic liver phantom, there were few scattered photons in the paper sheet phantom image. Furthermore, this laminated paper sheet phantom made handling of the source and its waste easier. If the paper sheet phantom will be designed more sophisticatedly, it becomes a useful tool for planar imaging experiments. (author)

  16. Effectiveness of mirror therapy, motor imagery, and virtual feedback on phantom limb pain following amputation: A systematic review.

    Science.gov (United States)

    Herrador Colmenero, Laura; Perez Marmol, Jose Manuel; Martí-García, Celia; Querol Zaldivar, María de Los Ángeles; Tapia Haro, Rosa María; Castro Sánchez, Adelaida María; Aguilar-Ferrándiz, María Encarnación

    2017-11-01

    Phantom limb pain is reported in 50%-85% of people with amputation. Clinical interventions in treating central pain, such as mirror therapy, motor imagery, or virtual visual feedback, could redound in benefits to amputee patients with phantom limb pain. To provide an overview of the effectiveness of different techniques for treating phantom limb pain in amputee patients. Systematic review. A computerized literature search up to April 2017 was performed using the following databases: PubMed, Scopus, CINAHL, MEDLINE, ProQuest, PEDro, EBSCOhost, and Cochrane Plus. Methodological quality and internal validity score of each study were assessed using PEDro scale. For data synthesis, qualitative methods from the Cochrane Back Review Group were applied. In all, 12 studies met our inclusion criteria, where 9 were rated as low methodological quality and 3 rated moderate quality. All studies showed a significant reduction in pain, but there was heterogeneity among subjects and methodologies and any high-quality clinical trial (PEDro score ≤8; internal validity score ≤5) was not found. Mirror therapy, motor imaginary, and virtual visual feedback reduce phantom limb pain; however, there is limited scientific evidence supporting their effectiveness. Future studies should include designs with more solid research methods, exploring short- and long-term benefits of these therapies. Clinical relevance This systematic review investigates the effectiveness of mirror therapy, motor imagery, and virtual visual feedback on phantom limb pain, summarizing the currently published trials and evaluating the research quality. Although these interventions have positive benefits in phantom limb pain, there is still a lack of evidence for supporting their effectiveness.

  17. Liver phantom for quality control and training in nuclear medicine

    International Nuclear Information System (INIS)

    Lima Ferreira, Fernanda Carla; Nascimento Souza, Divanizia do

    2011-01-01

    In nuclear medicine, liver scintigraphy aims to verify organ function based on the radionuclide concentration in the liver and bile flow and is also used to detect tumors. Therefore it is necessary to perform quality control tests in the gamma camera before running the exam to prevent false results. Quality control tests of the gamma camera should thus be performed before running the exam to prevent false results. Such tests generally use radioactive material inside phantoms for evaluation of gamma camera parameters in quality control procedures. Phantoms can also be useful for training doctors and technicians in nuclear medicine procedures. The phantom proposed here has artifacts that simulate nodules; it may take on different quantities, locations and sizes and it may also be mounted without the introduction of nodules. Thus, its images may show hot or cold nodules or no nodules. The phantom consists of acrylic plates hollowed out in the centre, with the geometry of an adult liver. Images for analyses of simulated liver scintigraphy were obtained with the detector device at 5 cm from the anterior surface of the phantom. These simulations showed that this object is suitable for quality control in nuclear medicine because it was possible to visualize artifacts larger than 7.9 mm using a 256x256 matrix and 1000 kcpm. The phantom constructed in this work will also be useful for training practitioners and technicians in order to prevent patients from repeat testing caused by error during examinations.

  18. Liver phantom for quality control and training in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Lima Ferreira, Fernanda Carla [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao, SE, 49100 000 (Brazil); Nascimento Souza, Divanizia do, E-mail: divanizi@ufs.br [Departamento de Fisica, Universidade Federal de Sergipe, Sao Cristovao, SE, 49100 000 (Brazil)

    2011-10-01

    In nuclear medicine, liver scintigraphy aims to verify organ function based on the radionuclide concentration in the liver and bile flow and is also used to detect tumors. Therefore it is necessary to perform quality control tests in the gamma camera before running the exam to prevent false results. Quality control tests of the gamma camera should thus be performed before running the exam to prevent false results. Such tests generally use radioactive material inside phantoms for evaluation of gamma camera parameters in quality control procedures. Phantoms can also be useful for training doctors and technicians in nuclear medicine procedures. The phantom proposed here has artifacts that simulate nodules; it may take on different quantities, locations and sizes and it may also be mounted without the introduction of nodules. Thus, its images may show hot or cold nodules or no nodules. The phantom consists of acrylic plates hollowed out in the centre, with the geometry of an adult liver. Images for analyses of simulated liver scintigraphy were obtained with the detector device at 5 cm from the anterior surface of the phantom. These simulations showed that this object is suitable for quality control in nuclear medicine because it was possible to visualize artifacts larger than 7.9 mm using a 256x256 matrix and 1000 kcpm. The phantom constructed in this work will also be useful for training practitioners and technicians in order to prevent patients from repeat testing caused by error during examinations.

  19. Liver phantom for quality control and training in nuclear medicine

    Science.gov (United States)

    Lima Ferreira, Fernanda Carla; Souza, Divanizia do Nascimento

    2011-10-01

    In nuclear medicine, liver scintigraphy aims to verify organ function based on the radionuclide concentration in the liver and bile flow and is also used to detect tumors. Therefore it is necessary to perform quality control tests in the gamma camera before running the exam to prevent false results. Quality control tests of the gamma camera should thus be performed before running the exam to prevent false results. Such tests generally use radioactive material inside phantoms for evaluation of gamma camera parameters in quality control procedures. Phantoms can also be useful for training doctors and technicians in nuclear medicine procedures. The phantom proposed here has artifacts that simulate nodules; it may take on different quantities, locations and sizes and it may also be mounted without the introduction of nodules. Thus, its images may show hot or cold nodules or no nodules. The phantom consists of acrylic plates hollowed out in the centre, with the geometry of an adult liver. Images for analyses of simulated liver scintigraphy were obtained with the detector device at 5 cm from the anterior surface of the phantom. These simulations showed that this object is suitable for quality control in nuclear medicine because it was possible to visualize artifacts larger than 7.9 mm using a 256×256 matrix and 1000 kcpm. The phantom constructed in this work will also be useful for training practitioners and technicians in order to prevent patients from repeat testing caused by error during examinations.

  20. New mechanism to cross the phantom divide

    OpenAIRE

    Du, Yunshuang; Zhang, Hongsheng; Li, Xin-Zhou

    2010-01-01

    Recently, type Ia supernovae data appear to support a dark energy whose equation of state $w$ crosses -1, which is a much more amazing problem than the acceleration of the universe. We show that it is possible for the equation of state to cross the phantom divide by a scalar field in the gravity with an additional inverse power-law term of Ricci scalar in the Lagrangian. The necessary and sufficient condition for a universe in which the dark energy can cross the phantom divide is obtained. So...

  1. BOMAB phantom manufacturing quality assurance study using Monte Carlo computations

    International Nuclear Information System (INIS)

    Mallett, M.W.

    1994-01-01

    Monte Carlo calculations have been performed to assess the importance of and quantify quality assurance protocols in the manufacturing of the Bottle-Manikin-Absorption (BOMAB) phantom for calibrating in vivo measurement systems. The parameters characterizing the BOMAB phantom that were examined included height, fill volume, fill material density, wall thickness, and source concentration. Transport simulation was performed for monoenergetic photon sources of 0.200, 0.662, and 1,460 MeV. A linear response was observed in the photon current exiting the exterior surface of the BOMAB phantom due to variations in these parameters. Sensitivity studies were also performed for an in vivo system in operation at the Pacific Northwest Laboratories in Richland, WA. Variations in detector current for this in vivo system are reported for changes in the BOMAB phantom parameters studied here. Physical justifications for the observed results are also discussed

  2. Momentary Parental Stress and Food-Related Parenting Practices.

    Science.gov (United States)

    Berge, Jerica M; Tate, Allan; Trofholz, Amanda; Fertig, Angela R; Miner, Michael; Crow, Scott; Neumark-Sztainer, Dianne

    2017-12-01

    Research suggests that stress and depressed mood are associated with food-related parenting practices (ie, parent feeding practices, types of food served at meals). However, current measures of parental stress, depressed mood, and food-related parenting practices are typically survey-based and assessed as static/unchanging characteristics, failing to account for fluctuations across time and context. Identifying momentary factors that influence parent food-related parenting practices will facilitate the development of effective interventions aimed at promoting healthy food-related parenting practices. In this study, we used ecological momentary assessment to examine the association between momentary factors (eg, stress, depressed mood) occurring early in the day and food-related parenting practices at the evening meal. Children aged 5 to 7 years and their families ( N = 150) from 6 racial and/or ethnic groups ( n = 25 each African American, Hispanic/Latino, Hmong, American Indian, Somali, and white families) were recruited for this mixed-methods study through primary care clinics. Higher stress and depressed mood earlier in the day predicted pressure-to-eat feeding practices and fewer homemade foods served at meals the same night. Effect modification was found for certain racial and/or ethnic groups with regard to engaging in pressure-to-eat feeding practices (ie, America Indian, Somali) or serving fewer homemade meals (ie, African American, Hispanic/Latino) in the face of high stress or depressed mood. Clinicians may want to consider discussing with parents the influence stress and depressed mood can have on everyday food-related parenting practices. Additionally, future researchers should consider using real-time interventions to reduce parental stress and depressed mood to promote healthy parent food-related parenting practices. Copyright © 2017 by the American Academy of Pediatrics.

  3. Hope and perceptions of parental role among parents assessed as maltreating their children.

    Science.gov (United States)

    Aram-Fichman, Reut; Davidson-Arad, Bilha

    2017-01-01

    The present study is anchored in the view that hope is a resource that fosters better coping and parenting. It examines the self-perceived hope and parental role of parents whom the welfare services in Israel have assessed as maltreating their children. The parents were recruited in 2010 through facilities for maltreated children. The study sample consisted of 262 parents (68.4% response rate), divided into those who had at least one child removed from home and those whose children were all at home. Both groups of parents reported moderately high basic and family hope and sense of pathways and agency, and moderate perceived parental role, with no significant group differences. Differences were found, however, in the role of hope in mediating between parents' sociodemographic features and their perceived parental role. The mediation was more substantial among the parents whose children were at home and differed in content. Only among parents whose children were at home did religiosity (β = 0.20, P hope, which increased the perceived parental role. Moreover, the findings underscore the lack of role of family hope and sense of agency among parents whose children were not at home. In both the groups, higher income led to greater hope (β = 0.18, P hope as a resource to help them improve their parenting, especially where the child was removed from home. © 2015 John Wiley & Sons Ltd.

  4. Control volume based hydrocephalus research; a phantom study

    Science.gov (United States)

    Cohen, Benjamin; Voorhees, Abram; Madsen, Joseph; Wei, Timothy

    2009-11-01

    Hydrocephalus is a complex spectrum of neurophysiological disorders involving perturbation of the intracranial contents; primarily increased intraventricular cerebrospinal fluid (CSF) volume and intracranial pressure are observed. CSF dynamics are highly coupled to the cerebral blood flows and pressures as well as the mechanical properties of the brain. Hydrocephalus, as such, is a very complex biological problem. We propose integral control volume analysis as a method of tracking these important interactions using mass and momentum conservation principles. As a first step in applying this methodology in humans, an in vitro phantom is used as a simplified model of the intracranial space. The phantom's design consists of a rigid container filled with a compressible gel. Within the gel a hollow spherical cavity represents the ventricular system and a cylindrical passage represents the spinal canal. A computer controlled piston pump supplies sinusoidal volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity and volume change as functions of time. Independent pressure measurements and momentum flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients and normal individuals. Flow and pressure measurements on the flow phantom will be presented through the control volume framework.

  5. Anisotropic Bianchi-I universe with phantom field and cosmological ...

    Indian Academy of Sciences (India)

    We study an anisotropic Bianchi-I universe in the presence of a phantom field and a cosmological constant. Cosmological solutions are obtained when the kinetic energy of the phantom field is of the order of anisotropy and dominates over the potential energy of the field. The anisotropy of the universe decreases and the ...

  6. A Unified Model of Phantom Energy and Dark Matter

    Directory of Open Access Journals (Sweden)

    Douglas Singleton

    2008-01-01

    Full Text Available To explain the acceleration of the cosmological expansion researchers have considered an unusual form of mass-energy generically called dark energy. Dark energy has a ratio of pressure over mass density which obeys $w=p/ ho <-1/3$. This form of mass-energy leads to accelerated expansion. An extreme form of dark energy, called phantom energy, has been proposed which has $w=p/ ho <-1$. This possibility is favored by the observational data. The simplest model for phantom energy involves the introduction of a scalar field with a negative kinetic energy term. Here we show that theories based on graded Lie algebras naturally have such a negative kinetic energy and thus give a model for phantom energy in a less ad hoc manner. We find that the model also contains ordinary scalar fields and anti-commuting (Grassmann vector fields which act as a form of two component dark matter. Thus from a gauge theory based on a graded algebra we naturally obtained both phantom energy and dark matter.

  7. Development of a phantom for quality control of radiosurgery

    International Nuclear Information System (INIS)

    Scheidegger Soboll, D.; Reuters Schelin, H.

    2008-01-01

    The aim of this work was to build a phantom for quality control of stereotactic radiosurgery on linear accelerators. The outward appearance is a translucent human head filled with water and enclosing an insert with test objects of known shapes. The phantom was submitted to computerized tomography, magnetic resonance imaging and angiography exams, in order to perform a radiosurgery planning. Contours of the internal structures on the therapy planning system were drawn over the MRI images. Through the image fusion of CT and MRI, the contour data was transferred to CT images. Stereotactic registration of CT and angiography was made. One isocenter treatment was created, and using the stereotactic coordinates given by the therapy planning system, the phantom was placed on a linac. X-ray images were performed in order to verify the final positioning of the planned isocenter. In the whole process the phantom showed usefulness and adequacy for the positioning quality control of stereotactic radiosurgery with linacs, according to the main documents concerning the issue. (author)

  8. Realistic torso phantom for calibration of in-vivo transuranic-nuclide counting facilities

    Energy Technology Data Exchange (ETDEWEB)

    Shirotani, Takashi

    1988-11-01

    A realistic torso phantom with average body size of Japanese adult males has been developed for the calibration of counting systems used for in-vivo measurements of plutonium and other actinides. The phantom contains removable model organs (lungs, liver, kidneys and heart), model trachea and artificial rib cage, and also includes chest plates that can be placed over the chest to simulate wide range adipose/muscle ratio in the human chest. Tissue substitutes used in the phantom were made of polyurethane with different concentrations of ester of phosphoric acid. Model lungs were made of foamed polyurethane with small quantities of the additive, and the artificial rib cage was made of epoxy resin with calcium carbonate. The experimental data have shown that the phantom can be used as a standard phantom for the calibration.

  9. Economic and other barriers to adopting recommendations to prevent childhood obesity: results of a focus group study with parents

    Directory of Open Access Journals (Sweden)

    Taveras Elsie M

    2009-12-01

    Full Text Available Abstract Background Parents are integral to the implementation of obesity prevention and management recommendations for children. Exploration of barriers to and facilitators of parental decisions to adopt obesity prevention recommendations will inform future efforts to reduce childhood obesity. Methods We conducted 4 focus groups (2 English, 2 Spanish among a total of 19 parents of overweight (BMI ≥ 85th percentile children aged 5-17 years. The main discussion focused on 7 common obesity prevention recommendations: reducing television (TV watching, removing TV from child's bedroom, increasing physically active games, participating in community or school-based athletics, walking to school, walking more in general, and eating less fast food. Parents were asked to discuss what factors would make each recommendation more difficult (barriers or easier (facilitators to follow. Participants were also asked about the relative importance of economic (time and dollar costs/savings barriers and facilitators if these were not brought into the discussion unprompted. Results Parents identified many barriers but few facilitators to adopting obesity prevention recommendations for their children. Members of all groups identified economic barriers (time and dollar costs among a variety of pertinent barriers, although the discussion of dollar costs often required prompting. Parents cited other barriers including child preference, difficulty with changing habits, lack of information, lack of transportation, difficulty with monitoring child behavior, need for assistance from family members, parity with other family members, and neighborhood walking safety. Facilitators identified included access to physical activity programs, availability of alternatives to fast food and TV which are acceptable to the child, enlisting outside support, dietary information, involving the child, setting limits, making behavior changes gradually, and parental change in shopping

  10. Parental adjustment and attitudes to parenting after in vitro fertilization.

    Science.gov (United States)

    Gibson, F L; Ungerer, J A; Tennant, C C; Saunders, D M

    2000-03-01

    To examine the psychosocial and parenthood-specific adjustment and attitudes to parenting at 1 year postpartum of IVF parents. Prospective, controlled study. Volunteers in a teaching hospital environment. Sixty-five primiparous women with singleton IVF pregnancies and their partners, and a control group of 61 similarly aged primiparous women with no history of infertility and their partners. Completion of questionnaires and interviews. Parent reports of general and parenthood-specific adjustment and attitudes to parenting. The IVF mothers tended to report lower self-esteem and less parenting competence than control mothers. Although there were no group differences on protectiveness, IVF mothers saw their children as significantly more vulnerable and "special" compared with controls. The IVF fathers reported significantly lower self-esteem and marital satisfaction, although not less competence in parenting. Both IVF mothers and fathers did not differ from control parents on other measures of general adjustment (mood) or those more specific to parenthood (e.g., attachment to the child and attitudes to child rearing). The IVF parents' adjustment to parenthood is similar to naturally conceiving comparison families. Nonetheless, there are minor IVF differences that reflect heightened child-focused concern and less confidence in parenting for mothers, less satisfaction with the marriage for the fathers, and vulnerable self-esteem for both parents.

  11. Phantom study of PET/CT guided delineation of radiation therapy volume

    International Nuclear Information System (INIS)

    Lin Lin; Zheng Rong; Wang Yibin; Geng Jianhua; Wu Ning; Zhao Ping

    2012-01-01

    Objective: To propose a model-based method for calculating the threshold in GTV determination by 18 F-FDG PET in a phantom study. Methods: A phantom was constructed of a 9 L cylindrical tank.Glass spheres with volumes ranging from 0.5 to 16 ml (0.5, 1, 2, 4, 8 and 16 ml) were suspended within the tank. The six spheres were filled with an identical concentration of FDG (203.5 MBq/L) and suspended within 3 different background baths of FDG (6.179, 16.021, 0 MBq/L) solutions, creating 3 target-to-background ratios of 32.96 : 1, 12.69 : 1 and target to zero background. A linear regressive function was constructed which represented the relationship between the threshold and the average activity concentration of the target. A 40% of maximum intensity threshold and the linear regressive function method were applied to define the spheres filled with 18 F-FDG. The volume differences between the two methods and the true volumes of the spheres were compared with t-test. Results: The linear regressive function model was derived as:threshold =(mean target concentration + 2.6227)/1.9752. The results indicated that a smaller deviation occurred when the function was utilized to estimate the volumes of the phantoms as compared to the 40% of maximum intensity threshold method, but there were no significant differences between them (t=0.306, P>0.05). The effect of the linear regressive function on volume was such that when the phantom sphere volumes were ≥ 1 ml, the average deviation between the defined volumes and the true volumes of phantoms was 1.01%; but when the phantom sphere volume was 0.5 ml, the average deviation was 9.53%. When the 40% of maximum intensity threshold method was applied to define the phantom spheres of volume ≥2 ml, the average deviation between the defined volumes and the true volumes of phantoms was -4.62%; but, the average deviation of that was 19.9% when the volumes of spheres were 0.5 and 1 ml. When the linear regressive function was applied to

  12. Development of a high resolution voxelised head phantom for medical physics applications.

    Science.gov (United States)

    Giacometti, V; Guatelli, S; Bazalova-Carter, M; Rosenfeld, A B; Schulte, R W

    2017-01-01

    Computational anthropomorphic phantoms have become an important investigation tool for medical imaging and dosimetry for radiotherapy and radiation protection. The development of computational phantoms with realistic anatomical features contribute significantly to the development of novel methods in medical physics. For many applications, it is desirable that such computational phantoms have a real-world physical counterpart in order to verify the obtained results. In this work, we report the development of a voxelised phantom, the HIGH_RES_HEAD, modelling a paediatric head based on the commercial phantom 715-HN (CIRS). HIGH_RES_HEAD is unique for its anatomical details and high spatial resolution (0.18×0.18mm 2 pixel size). The development of such a phantom was required to investigate the performance of a new proton computed tomography (pCT) system, in terms of detector technology and image reconstruction algorithms. The HIGH_RES_HEAD was used in an ad-hoc Geant4 simulation modelling the pCT system. The simulation application was previously validated with respect to experimental results. When compared to a standard spatial resolution voxelised phantom of the same paediatric head, it was shown that in pCT reconstruction studies, the use of the HIGH_RES_HEAD translates into a reduction from 2% to 0.7% of the average relative stopping power difference between experimental and simulated results thus improving the overall quality of the head phantom simulation. The HIGH_RES_HEAD can also be used for other medical physics applications such as treatment planning studies. A second version of the voxelised phantom was created that contains a prototypic base of skull tumour and surrounding organs at risk. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code.

    Science.gov (United States)

    Yoriyaz, H; dos Santos, A; Stabin, M G; Cabezas, R

    2000-07-01

    A new approach for calculating internal dose estimates was developed through the use of a more realistic computational model of the human body. The present technique shows the capability to build a patient-specific phantom with tomography data (a voxel-based phantom) for the simulation of radiation transport and energy deposition using Monte Carlo methods such as in the MCNP-4B code. MCNP-4B absorbed fractions for photons in the mathematical phantom of Snyder et al. agreed well with reference values. Results obtained through radiation transport simulation in the voxel-based phantom, in general, agreed well with reference values. Considerable discrepancies, however, were found in some cases due to two major causes: differences in the organ masses between the phantoms and the occurrence of organ overlap in the voxel-based phantom, which is not considered in the mathematical phantom.

  14. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, Biomedical Engeering Graduate Group, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered

  15. Alleviating Parenting Stress in Parents with Intellectual Disabilities: A Randomized Controlled Trial of a Video-Feedback Intervention to Promote Positive Parenting

    Science.gov (United States)

    Hodes, Marja W.; Meppelder, Marieke; Moor, Marleen; Kef, Sabina; Schuengel, Carlo

    2017-01-01

    Background: Adapted parenting support may alleviate the high levels of parenting stress experienced by many parents with intellectual disabilities. Methods: Parents with mild intellectual disabilities or borderline intellectual functioning were randomized to experimental (n = 43) and control (n = 42) conditions. Parents in both groups received…

  16. CT images of an anthropomorphic and anthropometric male pelvis phantom

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  17. CT images of an anthropomorphic and anthropometric male pelvis phantom

    International Nuclear Information System (INIS)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de

    2009-01-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  18. Phantom crash confirms models

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    To test computer models of how a nuclear reactor's containment building would fare if an airplane crashed into it, the Muto Institute in Tokyo sponsored a 3.2 million dollar project at Sandia National Laboratory to slam an F-4 Phantom jet into a 500 ton concrete wall. The results showed that the computer calculations were accurate

  19. Noncontact ultrasound imaging applied to cortical bone phantoms.

    Science.gov (United States)

    Bulman, J B; Ganezer, K S; Halcrow, P W; Neeson, Ian

    2012-06-01

    The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns. A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm(3) and in bone mineral density from 0 to 1.7 g/cm(3). Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of the in vivo range found in cortical bone. A total of 16-20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%-2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%-2%. Transmittance

  20. Influence of the PMMA and the ISO slab phantom for calibrating personal dosemeters

    International Nuclear Information System (INIS)

    Ginjaume, M.; Ortega, X.; Barbosa, A.

    2000-01-01

    Wide agreement has been achieved among the main Bodies and Organisations involved in standardisation of radiation protection, related to the operational quantities for personal dosimetry. Since their definition in 1985, several reports have been published to clarify and define the experimental set up to be used for the calibration of dosemeters in terms of the above-mentioned quantities. Among these lines, ICRU 47 has listed five different phantoms that are used for calibration and whose results were accurate, within accepted uncertainties. However, to achieve uniformity in calibration procedures, the 30 cm x 30 cm x 15 cm PMMA slab phantom was recommended. The secondary calibration Laboratory from the Institut de Techniques Energetiques at the Technical University of Catalonia (UPC) agreed with the Spanish Nacional Laboratory to adopt the recommended PMMA phantom but to improve the accuracy of the calibration procedure, by introducing a correction factor for backscatter differences in a PMMA and an ICRU slab phantom. Such corrections were of the order of 8% for the low-energy X-ray qualities. Recently, ISO in ISO 4037-3, has proposed the ISO water slab phantom which consists of a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (front wall 2.5 mm thick). This new phantom could be substituted by the above mentioned PMMA phantom for radiation qualities with mean energy equal or above that of 137 Cs. The aim of this work is to compare the influence of both phantoms when calibrating personal dosemeters with photons. A set of four TL personal dosemeters that are used in the UPC personal dosimetry Service and an electronic personal dosemeter (SIEMENS EPD-2) were calibrated in terms of H p (10) and H p (0.07) using the two proposed phantoms. Calibration factors for ISO X-ray narrow spectra, 137 Cs and 60 Co were experimentally obtained for each phantom and compared. In the TL measurements, differences were found to be within TL statistical uncertainty, provided that a

  1. Leveraging text messaging and mobile technology to support pediatric obesity-related behavior change: a qualitative study using parent focus groups and interviews.

    Science.gov (United States)

    Sharifi, Mona; Dryden, Eileen M; Horan, Christine M; Price, Sarah; Marshall, Richard; Hacker, Karen; Finkelstein, Jonathan A; Taveras, Elsie M

    2013-12-06

    Text messaging (short message service, SMS) is a widely accessible and potentially cost-effective medium for encouraging behavior change. Few studies have examined text messaging interventions to influence child health behaviors or explored parental perceptions of mobile technologies to support behavior change among children. Our aim was to examine parental acceptability and preferences for text messaging to support pediatric obesity-related behavior change. We conducted focus groups and follow-up interviews with parents of overweight and obese children, aged 6-12 years, seen for "well-child" care in eastern Massachusetts. A professional moderator used a semistructured discussion guide and sample text messages to catalyze group discussions. Seven participants then received 3 weeks of text messages before a follow-up one-on-one telephone interview. All focus groups and interviews were recorded and transcribed verbatim. Using a framework analysis approach, we systematically coded and analyzed group and interview data to identify salient and convergent themes. We reached thematic saturation after five focus groups and seven follow-up interviews with a total of 31 parents of diverse race/ethnicity and education levels. Parents were generally enthusiastic about receiving text messages to support healthy behaviors for their children and preferred them to paper or email communication because they are brief and difficult to ignore. Participants anticipated high responsiveness to messaging endorsed by their child's doctor and indicated they would appreciate messages 2-3 times/week or more as long as content remains relevant. Suggestions for maintaining message relevance included providing specific strategies for implementation and personalizing information. Most felt the negative features of text messaging (eg, limited message size) could be overcome by providing links within messages to other media including email or websites. Text messaging is a promising medium for

  2. Radiological equipment analyzed by specific developed phantoms and software

    International Nuclear Information System (INIS)

    Soto, M.; Campayo, J. M.; Mayo, P.; Verdu, G.; Rodenas, F.

    2010-10-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  3. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  4. Effects of Cognitive Versus Cognitive-Behavioral Divorce-Parenting Programs on Parental Conflict, Intimate Violence, Parental Communication, Divorce-Related Parental Behaviors and Children's Behavioral Problems

    National Research Council Canada - National Science Library

    Whitworth, James

    2000-01-01

    .... The two-group pretest- posttest design with a three-month follow-up measured parents knowledge of divorce-related parenting behaviors, reports of intimate violence, destructive conflict tactics...

  5. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  6. TU-H-206-02: Novel Linearly-Filled Derenzo PET Phantom Design

    International Nuclear Information System (INIS)

    Graves, S; Cox, B; Valdovinos, H; Jeffery, J; Eliceiri, K; Barnhart, T; Nickles, R; Farhoud, M

    2016-01-01

    Purpose: To design a linearly-filled Derenzo positron emission tomography (PET) phantom, eliminating the extraneous radioisotope volumes in a conventional reservoir-type design. This activity reduction combined with the elimination of bubbles in smaller phantom channels would significantly reduce personnel dose, radioisotope cost, and would improve image quality by reducing out-of-slice activity scatter. Methods: A computer-aided design (CAD) was created of a modular Derenzo phantom consisting of three phantom layers with gaskets between the layers. The central piece contains the active pattern volume and channels connecting adjacent rods in a serpentine pattern. The two end-pieces contained an inlet and an outlet for filling purposes. Phantom prototypes were 3D printed on a Viper Si2 stereolithography machine. The two gaskets were fabricated from silicon sheets using a PLS 6.75 laser cutter. Phantoms were held together by pass-through glass-filled nylon bolts and nuts. Phantoms were filled with "5"2Mn, "6"4Cu, "7"4Br, and "1"2"4I for testing, and were imaged on a Siemens Inveon MicroPET scanner. Results: Four phantom prototypes were constructed using male Leur Lock fittings for inlet/outlet ports. 3D printed layers were sanded to ensure proper coupling to the silicon gaskets. The filling volume for each prototype was approximately 2.4 mL. The filling process was found to be rapid, leak-tight, and with minimal back-pressure. PET images were reconstructed by OSEM3D, and axial slices along the phantom pattern length were averaged to provide final images. Image distortion was isotope dependent with "5"2Mn and "6"4Cu having the least distortion and "1"2"4I having the most distortion. Conclusion: These results indicate that the linearlyfilled Derenzo design improves on conventional reservoir-type designs by eliminating potential bubbles in small channels and by reducing activity level, radioisotope volume, radioisotope cost, personnel dose, filling time, and out

  7. Fabrication of a phantom and its application for checking gamma camera performance

    International Nuclear Information System (INIS)

    Yesmin, S; Ahmad, G. U.; Afroz, S.; Hossain, S.; Rashid, H.

    2004-01-01

    The primary aim of the present work is to fabricate a total performance phantom, which could be used for checking the performance characteristics of gamma camera. The phantom was locally fabricated at machine shop of Bangladesh University of Engineering and Technology (BUET) and used for checking the performance characteristics of gamma camera LF-61 of Centre for Nuclear Medicine and Ultrasound, Dhaka. With 10 mCi of Tc-99m, imaging of the phantom acquired with a reasonable counts. The image was inspected physically for evaluation of the camera performances. The visual inspection of the phantom image revealed that the performance characteristics like: spatial resolution, linearity, uniformity and lesion detection capability of the gamma camera could clearly be evaluated with reasonable acceptance level. This phantom is expected to be useful for checking performance characteristics of SPECT system as well. (author)

  8. Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, K. M.; Ebert, M. A.; Kron, T.; Howlett, S. J.; Cornes, D.; Hamilton, C. S.; Denham, J. W. [Department of Radiation Oncology, Calvary Mater Newcastle, Waratah, New South Wales 2298, Australia and School of Physics, University of Newcastle, New South Wales 2308 (Australia); Department of Radiation Oncology, Sir Charles Gairdner Hospital, Western Australia, Australia and School of Physics, University of Western Australia, Western Australia 6009 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre, Victoria 8006 (Australia); Australiasian College of Physical Scientists and Engineers in Medicine, Sydney, New South Wales 2020 (Australia); Trans-Tasman Radiation Oncology Group, Calvary Mater Newcastle, New South Wales 2298 (Australia); Heidelberg Repatriation Hospital, Victoria 3081 (Australia); Department of Radiation Oncology, Calvary Mater Newcastle, Waratah, New South Wales 2298, Australia and School of Medicine and Population Health, University of Newcastle, New South Wales 2308 (Australia)

    2011-10-15

    Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

  9. A new head phantom with realistic shape and spatially varying skull resistivity distribution.

    Science.gov (United States)

    Li, Jian-Bo; Tang, Chi; Dai, Meng; Liu, Geng; Shi, Xue-Tao; Yang, Bin; Xu, Can-Hua; Fu, Feng; You, Fu-Sheng; Tang, Meng-Xing; Dong, Xiu-Zhen

    2014-02-01

    Brain electrical impedance tomography (EIT) is an emerging method for monitoring brain injuries. To effectively evaluate brain EIT systems and reconstruction algorithms, we have developed a novel head phantom that features realistic anatomy and spatially varying skull resistivity. The head phantom was created with three layers, representing scalp, skull, and brain tissues. The fabrication process entailed 3-D printing of the anatomical geometry for mold creation followed by casting to ensure high geometrical precision and accuracy of the resistivity distribution. We evaluated the accuracy and stability of the phantom. Results showed that the head phantom achieved high geometric accuracy, accurate skull resistivity values, and good stability over time and in the frequency domain. Experimental impedance reconstructions performed using the head phantom and computer simulations were found to be consistent for the same perturbation object. In conclusion, this new phantom could provide a more accurate test platform for brain EIT research.

  10. Effectiveness of the Lunch is in the Bag program on communication between the parent, child and child-care provider around fruits, vegetables and whole grain foods: A group-randomized controlled trial.

    Science.gov (United States)

    Sharma, Shreela V; Rashid, Tasnuva; Ranjit, Nalini; Byrd-Williams, Courtney; Chuang, Ru-Jye; Roberts-Gray, Cynthia; Briley, Margaret; Sweitzer, Sara; Hoelscher, Deanna M

    2015-12-01

    To evaluate the effectiveness of the parent- and early care education (ECE) center-based Lunch is in the Bag program on communication between parent, child, and their ECE center providers around fruits, vegetables and whole grain foods (FVWG). A total of n=30 ECE center; 577 parent-child dyads participated in this group-randomized controlled trial conducted from 2011 to 2013 in Texas (n=15 ECE center, 327 dyads intervention group; n=15 ECE center, 250 dyads comparison group). Parent-child and parent-ECE center provider communication was measured using a parent-reported survey administered at baseline and end of the five-week intervention period. Multilevel linear regression analysis was used to compare the pre-to-post intervention changes in the parent-child and parent-ECE center provider communication scales. Significance was set at pparent-child and parent-ECE center provider communication scores were low. There was a significant increase post-intervention in the parent-ECE center provider communication around vegetables (Adjusted β=0.78, 95%CI: 0.13, 1.43, p=0.002), and around fruit (Adjusted β=0.62, 95%CI: 0.04, 0.20, p=0.04) among the parents in the intervention group as compared to those in the comparison group. There were no significant intervention effects on parent-child communication. Lunch is in the Bag had significant positive effects on improving communication between the parents and ECE center providers around FVWG. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Anthropomorphic Phantoms for Confirmation of Linear Accelerator-Based Small Animal Irradiation.

    Science.gov (United States)

    Perks, Julian R; Lucero, Steven; Monjazeb, Arta M; Li, Jian Jian

    2015-03-01

    Three dimensional (3D) scanning and printing technology is utilized to create phantom models of mice in order to assess the accuracy of ionizing radiation dosing from a clinical, human-based linear accelerator. Phantoms are designed to simulate a range of research questions, including irradiation of lung tumors and primary subcutaneous or orthotopic tumors for immunotherapy experimentation. The phantoms are used to measure the accuracy of dose delivery and then refine it to within 1% of the prescribed dose.

  12. A low-cost phantom for simple routine testing of single photon emission computed tomography (SPECT) cameras

    International Nuclear Information System (INIS)

    Ng, A.H.; Ng, K.H.; Dharmendra, H.; Perkins, A.C.

    2009-01-01

    A simple sphere test phantom has been developed for routine performance testing of SPECT systems in situations where expensive commercial phantoms may not be available. The phantom was based on a design with six universal syringe hubs set in the frame to support a circular array of six glass blown spheres of different sizes. The frame was then placed into a water-filled CT abdomen phantom and scanned with a triple head camera system (Philips IRIX TM , USA). Comparison was made with a commercially available phantom (Deluxe Jaszczak phantom). Whereas the commercial phantom demonstrates cold spot resolution, an important advantage of the sphere test phantom was that hot spot resolution could be easily measured using almost half (370 MBq) of the activity recommended for use in the commercial phantom. Results showed that the contrast increased non-linearly with sphere volume and radionuclide concentration. The phantom was found to be suitable as an inexpensive option for daily performance tests.

  13. ANTHROPOMORPHIC PHANTOMS FOR ASSESSMENT OF STRAIN IMAGING METHODS INVOLVING SALINE-INFUSED SONOHYSTEROGRAPHY

    Science.gov (United States)

    Hobson, Maritza A.; Madsen, Ernest L.; Frank, Gary R.; Jiang, Jingfeng; Shi, Hairong; Hall, Timothy J.; Varghese, Tomy

    2008-01-01

    Two anthropomorphic uterine phantoms were developed which allow assessment and comparison of strain imaging systems adapted for use with saline-infused sonohysterography (SIS). Tissue-mimicking (TM) materials consist of dispersions of safflower oil in gelatin. TM fibroids are stiffer than the TM myometrium/cervix and TM polyps are softer. The first uterine phantom has 3-mm diameter TM fibroids randomly distributed in TM myometrium. The second uterine phantom has a 5-mm and an 8-mm spherical TM fibroid in addition to a 5-mm spherical and a 12.5-mm long (medicine-capsule-shaped) TM endometrial polyp protruding into the endometrial cavity; also, a 10-mm spherical TM fibroid projects from the serosal surface. Strain images using the first phantom show the stiffer 3-mm TM fibroids in the myometrium. Results from the second uterine phantom show that, as expected, parts of inclusions projecting into the uterine cavity will appear very stiff, whether they are stiff or soft. Results from both phantoms show that even though there is a five-fold difference in the Young’s moduli values, there is not a significant difference in the strain in the transition from the TM myometrium to the TM fat. These phantoms allow for realistic comparison and evolution of SIS strain imaging techniques and can aid clinical personnel to develop skills for SIS strain imaging. PMID:18514999

  14. Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

    International Nuclear Information System (INIS)

    Batista Nogueira, Luciana; Lemos Silva, Hugo Leonardo; Donato da Silva, Sabrina; Passos Ribeiro Campos, Tarcisio

    2015-01-01

    This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic films EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm 2 each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed

  15. Effectiveness of Mindfulness-Based Parenting Educational Program on the Anxiety, Parent-Child Conflict and Parent Self-Agency in Mothers with Oppositional Defiant Disorder Children

    Directory of Open Access Journals (Sweden)

    F. Ghazanfari

    2017-09-01

    Full Text Available Aims: Oppositional defiant disorder that occurs in pre-school or early school-age children and in pre-adolescent stage has a widespread impact on the child, family, teachers and society. The aim of the study was to determine the effect of mindful parenting education program on reducing the anxiety and parent-child conflict and increasing the self-agency of parenting in mothers who have oppositional defiant disorder daughters. Materials & Methods: This semi-experimental study with a pretest-posttest control group was performed during 2015-2016 academic year in 34 mothers of primary school girl students of Noorabad City, Iran, who were suffering from oppositional defiant disorder. The samples were selected by purposeful clustering method and were randomly divided into 2 test and control groups (each had 17 members. The research tools were Child Behavioral Logbook and Teacher Report Form, Beck Anxiety Inventory, Conflict Strategy and Parent Self-efficacy Questionnaires. Mindfulness-based parenting educational program was conducted for the experimental group one 2-hour session a week for 2 months. Data were analyzed by SPSS 23 software using MANCOVA test. Findings: The average of total anxiety, parent-child conflict and parental self-efficacy scores were higher in the experimental group in posttest. After controlling the effect of pre-test scores, there were significant differences between the test and control groups in terms of all variables (p<0.001. Conclusion: Mindfulness-based parenting educational program reduces the anxiety and parent-child conflict and increases the parental self-efficacy in mothers with oppositional defiant disorder.

  16. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  17. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  18. Viscosity-Induced Crossing of the Phantom Barrier

    Directory of Open Access Journals (Sweden)

    Iver Brevik

    2015-09-01

    Full Text Available We show explicitly, by using astrophysical data plus reasonable assumptions for the bulk viscosity in the cosmic fluid, how the magnitude of this viscosity may be high enough to drive the fluid from its position in the quintessence region at present time t = 0 across the barrier w = −1 into the phantom region in the late universe. The phantom barrier is accordingly not a sharp mathematical divide, but rather a fuzzy concept. We also calculate the limiting forms of various thermodynamical quantities, including the rate of entropy production, for a dark energy fluid near the future Big Rip singularity.

  19. Construction of voxel head phantom and application to BNCT dose calculation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Sik; Lee, Choon Ik; Lee, Jai Ki [Hanyang Univ., Seoul (Korea, Republic of)

    2001-06-15

    Voxel head phantom for overcoming the limitation of mathematical phantom in depicting anatomical details was constructed and example dose calculation for BNCT was performed. The repeated structure algorithm of the general purpose Monte Carlo code, MCNP4B was applied for voxel Monte Carlo calculation. Simple binary voxel phantom and combinatorial geometry phantom composed of two materials were constructed for validating the voxel Monte Carlo calculation system. The tomographic images of VHP man provided by NLM(National Library of Medicine) were segmented and indexed to construct voxel head phantom. Comparison od doses for broad parallel gamma and neutron beams in AP and PA directions showed decrease of brain dose due to the attenuation of neutron in eye balls in case of voxel head phantom. The spherical tumor volume with diameter, 5cm was defined in the center of brain for BNCT dose calculation in which accurate 3 dimensional dose calculation is essential. As a result of BNCT dose calculation for downward neutron beam of 10keV and 40keV, the tumor dose is about doubled when boron concentration ratio between the tumor to the normal tissue is 30{mu}g/g to 3 {mu}g/g. This study established the voxel Monte Carlo calculation system and suggested the feasibility of precise dose calculation in therapeutic radiology.

  20. SU-F-BRE-04: Construction of 3D Printed Patient Specific Phantoms for Dosimetric Verification Measurements

    International Nuclear Information System (INIS)

    Ehler, E; Higgins, P; Dusenbery, K

    2014-01-01

    Purpose: To validate a method to create per patient phantoms for dosimetric verification measurements. Methods: Using a RANDO phantom as a substitute for an actual patient, a model of the external features of the head and neck region of the phantom was created. A phantom was used instead of a human for two reasons: to allow for dosimetric measurements that would not be possible in-vivo and to avoid patient privacy issues. Using acrylonitrile butadiene styrene thermoplastic as the building material, a hollow replica was created using the 3D printer filled with a custom tissue equivalent mixture of paraffin wax, magnesium oxide, and calcium carbonate. A traditional parallel-opposed head and neck plan was constructed. Measurements were performed with thermoluminescent dosimeters in both the RANDO phantom and in the 3D printed phantom. Calculated and measured dose was compared at 17 points phantoms including regions in high and low dose regions and at the field edges. On-board cone beam CT was used to localize both phantoms within 1mm and 1° prior to radiation. Results: The maximum difference in calculated dose between phantoms was 1.8% of the planned dose (180 cGy). The mean difference between calculated and measured dose in the anthropomorphic phantom and the 3D printed phantom was 1.9% ± 2.8% and −0.1% ± 4.9%, respectively. The difference between measured and calculated dose was determined in the RANDO and 3D printed phantoms. The differences between measured and calculated dose in each respective phantom was within 2% for 12 of 17 points. The overlap of the RANDO and 3D printed phantom was 0.956 (Jaccard Index). Conclusion: A custom phantom was created using a 3D printer. Dosimetric calculations and measurements showed good agreement between the dose in the RANDO phantom (patient substitute) and the 3D printed phantom

  1. SU-F-BRE-04: Construction of 3D Printed Patient Specific Phantoms for Dosimetric Verification Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ehler, E; Higgins, P; Dusenbery, K [University of Minnesota, Minneapolis, MN (United States)

    2014-06-15

    Purpose: To validate a method to create per patient phantoms for dosimetric verification measurements. Methods: Using a RANDO phantom as a substitute for an actual patient, a model of the external features of the head and neck region of the phantom was created. A phantom was used instead of a human for two reasons: to allow for dosimetric measurements that would not be possible in-vivo and to avoid patient privacy issues. Using acrylonitrile butadiene styrene thermoplastic as the building material, a hollow replica was created using the 3D printer filled with a custom tissue equivalent mixture of paraffin wax, magnesium oxide, and calcium carbonate. A traditional parallel-opposed head and neck plan was constructed. Measurements were performed with thermoluminescent dosimeters in both the RANDO phantom and in the 3D printed phantom. Calculated and measured dose was compared at 17 points phantoms including regions in high and low dose regions and at the field edges. On-board cone beam CT was used to localize both phantoms within 1mm and 1° prior to radiation. Results: The maximum difference in calculated dose between phantoms was 1.8% of the planned dose (180 cGy). The mean difference between calculated and measured dose in the anthropomorphic phantom and the 3D printed phantom was 1.9% ± 2.8% and −0.1% ± 4.9%, respectively. The difference between measured and calculated dose was determined in the RANDO and 3D printed phantoms. The differences between measured and calculated dose in each respective phantom was within 2% for 12 of 17 points. The overlap of the RANDO and 3D printed phantom was 0.956 (Jaccard Index). Conclusion: A custom phantom was created using a 3D printer. Dosimetric calculations and measurements showed good agreement between the dose in the RANDO phantom (patient substitute) and the 3D printed phantom.

  2. SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Z; Vijayan, S; Kilian-Meneghin, J; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2016-06-15

    Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms using a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems

  3. Development of age-specific Japanese physical phantoms for dose evaluation in infant CT examinations

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Imai, K.; Ikeda, M.; Akahane, K.; Obara, S.; Yamauchi, M.; Narai, K.; Katsu, T.

    2016-01-01

    Secondary to the previous development of age-specific Japanese head phantoms, the authors designed Japanese torso phantoms for dose assessment in infant computed tomography (CT) examinations and completed a Japanese 3-y-old head-torso phantom. For design of age-specific torso phantoms (0, 0.5, 1 and 3 y old), anatomical structures were measured from CT images of Japanese infant patients. From the CT morphometry, it was found that rib cages of Japanese infants were smaller than those in Europeans and Americans. Radiophotoluminescence glass dosemeters were used for dose measurement of a 3-y-old head-torso phantom. To examine the validity of the developed phantom, organ and effective doses by the in-phantom dosimetry system were compared with simulation values in a web-based CT dose calculation system (WAZA-ARI). The differences in doses between the two systems were <20 % at the doses of organs within scan regions and effective doses in head, chest and abdomino-pelvic CT examinations. (authors)

  4. Development of a three-dimensionally movable phantom system for dosimetric verifications

    International Nuclear Information System (INIS)

    Nakayama, Hiroshi; Mizowaki, Takashi; Narita, Yuichiro; Kawada, Noriyuki; Takahashi, Kunio; Mihara, Kazumasa; Hiraoka, Masahiro

    2008-01-01

    The authors developed a three-dimensionally movable phantom system (3D movable phantom system) which can reproduce three-dimensional movements to experimentally verify the impact of radiotherapy treatment-related movements on dose distribution. The phantom system consists of three integrated components: a three-dimensional driving mechanism (3D driving mechanism), computer control system, and phantoms for film dosimetry. The 3D driving mechanism is a quintessential part of this system. It is composed of three linear-motion tables (single-axis robots) which are joined orthogonally to each other. This mechanism has a motion range of 100 mm, with a maximum velocity of 200 mm/s in each dimension, and 3D motion ability of arbitrary patterns. These attributes are sufficient to reproduce almost all organ movements. The positional accuracy of this 3D movable phantom system in a state of geostationary is less than 0.1 mm. The maximum error in terms of the absolute position on movement was 0.56 mm. The positional reappearance error on movement was up to 0.23 mm. The observed fluctuation of time was 0.012 s in the cycle of 4.5 s of oscillation. These results suggested that the 3D movable phantom system exhibited a sufficient level of accuracy in terms of geometry and timing to reproduce interfractional organ movement or setup errors in order to assess the influence of these errors on high-precision radiotherapy such as stereotactic irradiation and intensity-modulated radiotherapy. In addition, the authors 3D movable phantom system will also be useful in evaluating the adequacy and efficacy of new treatment techniques such as gating or tracking radiotherapy

  5. WE-D-303-01: Development and Application of Digital Human Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Segars, P. [Duke University, Durham, NC (United States)

    2015-06-15

    Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

  6. WE-D-303-01: Development and Application of Digital Human Phantoms

    International Nuclear Information System (INIS)

    Segars, P.

    2015-01-01

    Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems

  7. Determination of optimum filter in myocardial SPECT: A phantom study

    International Nuclear Information System (INIS)

    Takavar, A.; Shamsipour, Gh.; Sohrabi, M.; Eftekhari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images. Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc was injected into the phantom. Images was taken from this phantom. Some filters including Parzen, Hamming, Hanning, Butter worth and Gaussian were exerted on the phantom images. By defining some criteria such as contrast, signal to noise ratio, and defect size detectability, the best filter can be determined. Results: 0.325 Nyquist frequency and 0.5 nq was obtained as the optimum cut off frequencies respectively for hamming and handing filters. Order 11, cut off 0.45 Nq and order 20 cut off 0.5 Nq obtained optimum respectively for Butter worth and Gaussian filters. Conclusion: The optimum member of every filter's family was obtained

  8. Development of mathematical pediatric phantoms for internal dose calculations: designs, limitations, and prospects

    International Nuclear Information System (INIS)

    Cristy, M.

    1980-01-01

    Mathematical phantoms of the human body at various ages are employed with Monte Carlo radiation transport codes for calculation of photon specific absorbed fractions. The author has developed a pediatric phantom series based on the design of the adult phantom, but with explicit equations for each organ so that organ sizes and marrow distributions could be assigned properly. Since the phantoms comprise simple geometric shapes, predictive dose capability is limited when geometry is critical to the calculation. Hence, there is a demand for better phantom design in situations where geometry is critical, such as for external irradiation or for internal emitters with low energy photons. Recent advances in computerized axial tomography (CAT) present the potential for derivation of anatomical information, which is so critical to development of phantoms, and ongoing developmental work on compuer architecture to handle large arrays for Monte Carlo calculations should make complex-geometry dose calculations economically feasible within this decade

  9. The relationship between maternal self-efficacy and parenting practices: implications for parent training.

    Science.gov (United States)

    Sanders, M R; Woolley, M L

    2005-01-01

    The present study examined the relationship between maternal self-efficacy, dysfunctional discipline practices and child conduct problems. Specifically, three levels of self-efficacy, global, domain and task-specific self-efficacy, were assessed in mothers of 2- to 8-year-old children with conduct problems (clinic group, n=45) and non-clinic mothers from the community (non-clinic group, n=79). Measures of global, domain and task-specific self-efficacy were completed by mothers. Clinic mothers reported significantly lower self-efficacy than non-clinic mothers for all but one of the parenting tasks assessed. Both groups of mothers reported lowest self-efficacy for similar parenting tasks. In the sample as a whole self-efficacy measures were significant predictors of maternal discipline style after controlling for other parent, child and risk factors. Of the self-efficacy variables behavioural self-efficacy was the best predictor of mothers discipline style. The findings support the importance of developing parenting strategies that enable parents to generalize their parenting skills to a diverse range of diverse parenting contexts both in the home and in the community.

  10. Population of 224 realistic human subject-based computational breast phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, David W. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Wells, Jered R., E-mail: jered.wells@duke.edu [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Sturgeon, Gregory M. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Dobbins, James T. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Segars, W. Paul [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Lo, Joseph Y. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Electrical and Computer Engineering and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2016-01-15

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range

  11. A novel composite material specifically developed for ultrasound bone phantoms: cortical, trabecular and skull

    International Nuclear Information System (INIS)

    Wydra, A; Maev, R Gr

    2013-01-01

    In the various stages of developing diagnostic and therapeutic equipment, the use of phantoms can play a very important role in improving the process, help in implementation, testing and calibrations. Phantoms are especially useful in developing new applications and training new doctors in medical schools. However, devices that use different physical factors, such as MRI, Ultrasound, CT Scan, etc will require the phantom to be made of different physical properties. In this paper we introduce the properties of recently designed new materials for developing phantoms for ultrasonic human body investigation, which in today's market make up more than 30% in the world of phantoms. We developed a novel composite material which allows fabrication of various kinds of ultrasound bone phantoms to mimic most of the acoustical properties of human bones. In contrast to the ex vivo tissues, the proposed material can maintain the physical and acoustical properties unchanged for long periods of time; moreover, these properties can be custom designed and created to suit specific needs. As a result, we introduce three examples of ultrasound phantoms that we manufactured in our laboratory: cortical, trabecular and skull bone phantoms. The paper also presents the results of a comparison study between the acoustical and physical properties of actual human bones (reported in the referenced literatures) and the phantoms manufactured by us. (note)

  12. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited.

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  13. Influence of different types of phantoms on the calibration of dosemeters for eye lens dosimetry

    International Nuclear Information System (INIS)

    Yoshitomi, H.; Kowatari, M.

    2016-01-01

    Both a cylinder and a slab phantom have been recommended to be used as calibration phantoms for eye lens dosimetry in the International Atomic Energy Agency TECDOC. This study describes investigations on the influence of the type of phantom on the calibration of dosemeters. In order to fulfil the purpose, backscatter radiation from practically used water-filled phantoms was evaluated by calculations and experiments. For photons, the calculations showed that the cylinder phantom had 10 % lower backscattered effect at maximum than a slab phantom, and simulated well the backscattered effect of the human head or neck to within ±10 %. The irradiation results of non-filtered optically stimulated luminescence and radio-photoluminescence glass dosemeters indicated that the differences of the calibration factors between the two types of phantoms were up to 20 and 10 %, respectively, reflecting the response to backscattered photons. For electrons, no difference was found between the two types of phantoms. (authors)

  14. Survey of potential use of dynamic line phantom for quality control of Gamma camera

    International Nuclear Information System (INIS)

    Trindev, P.; Ozturk, N.

    2004-01-01

    Different phantoms, used to evaluate the essential for image quality parameters of gamma cameras in order to avoid artefacts, are presented. The prices are significant and it is a sensible approach to optimise the type and number of phantoms necessary for quality control. Among all phantoms the price of 'Dynamic Line Phantom' (DLP) is impressive, but it is announced to substitute several 'passive' and 'active' phantoms. The goal of this paper is to justify this statement. The programs, based on image profile are discussed in the paper and the practical uses of the different programs are given

  15. Evaluation of Banana Hypersensitivity Among a Group of Atopic Egyptian Children: Relation to Parental/Self Reports

    OpenAIRE

    El-Sayed, Zeinab A.; El-Ghoneimy, Dalia H.; El-Shennawy, Dina; Nasser, Manar W.

    2013-01-01

    Purpose To evaluate the frequency of banana sensitization and allergy among a group of atopic Egyptian children in relation to parental/self reports. Methods This is a case-control study included 2 groups of allergic children with and without history of banana allergy, each included 40 patients. They were subjected to skin prick test (SPT) using commercial banana allergen extract and prick-prick test (PPT) using raw banana, in addition to measuring the serum banana-specific IgE. Oral banana c...

  16. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Segars, W. P.; Bond, Jason; Frush, Jack; Hon, Sylvia; Eckersley, Chris; Samei, E. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Williams, Cameron H.; Frush, D. [Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Feng Jianqiao; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I. [Center for Imaging Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2013-04-15

    Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest-abdomen-pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore, serve

  17. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization

    International Nuclear Information System (INIS)

    Segars, W. P.; Bond, Jason; Frush, Jack; Hon, Sylvia; Eckersley, Chris; Samei, E.; Williams, Cameron H.; Frush, D.; Feng Jianqiao; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.

    2013-01-01

    Purpose: The authors previously developed the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. The XCAT consisted of highly detailed whole-body models for the standard male and female adult, including the cardiac and respiratory motions. In this work, the authors extend the XCAT beyond these reference anatomies by developing a series of anatomically variable 4D XCAT adult phantoms for imaging research, the first library of 4D computational phantoms. Methods: The initial anatomy of each phantom was based on chest–abdomen–pelvis computed tomography data from normal patients obtained from the Duke University database. The major organs and structures for each phantom were segmented from the corresponding data and defined using nonuniform rational B-spline surfaces. To complete the body, the authors manually added on the head, arms, and legs using the original XCAT adult male and female anatomies. The structures were scaled to best match the age and anatomy of the patient. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from the template XCAT phantom (male or female) to the target patient model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. Each new phantom was refined by checking for anatomical accuracy via inspection of the models. Results: Using these methods, the authors created a series of computerized phantoms with thousands of anatomical structures and modeling cardiac and respiratory motions. The database consists of 58 (35 male and 23 female) anatomically variable phantoms in total. Like the original XCAT, these phantoms can be combined with existing simulation packages to simulate realistic imaging data. Each new phantom contains parameterized models for the anatomy and the cardiac and respiratory motions and can, therefore

  18. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  19. Influence of lucite phantoms on calibration of dosimetric pens

    International Nuclear Information System (INIS)

    Oliveira, E.C.; Xavier, M.; Caldas, L.E.V.

    1992-01-01

    Dosimetrical pens were studied for the answer repetition and were tested in gamma radiation fields ( 60 Co and 137 Cs) in air and in front of a lucite phantom, obtaining a backscattering contribution. The medium backscattering factors were 1,053 and 1,108 for respectively 60 Co and 137 Cs. The pens were placed behind the phantom for verifying the radiation attenuation. (C.G.C.)

  20. Verification of gamma knife based fractionated radiosurgery with newly developed head-thorax phantom

    International Nuclear Information System (INIS)

    Bisht, Raj Kishor; Kale, Shashank Sharad; Natanasabapathi, Gopishankar; Singh, Manmohan Jit; Agarwal, Deepak; Garg, Ajay; Rath, Goura Kishore; Julka, Pramod Kumar; Kumar, Pratik; Thulkar, Sanjay; Sharma, Bhawani Shankar

    2016-01-01

    Objective: Purpose of the study is to verify the Gamma Knife Extend™ system (ES) based fractionated stereotactic radiosurgery with newly developed head-thorax phantom. Methods: Phantoms are extensively used to measure radiation dose and verify treatment plan in radiotherapy. A human upper body shaped phantom with thorax was designed to simulate fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife. The central component of the phantom aids in performing radiological precision test, dosimetric evaluation and treatment verification. A hollow right circular cylindrical space of diameter 7.0 cm was created at the centre of this component to place various dosimetric devices using suitable adaptors. The phantom is made of poly methyl methacrylate (PMMA), a transparent thermoplastic material. Two sets of disk assemblies were designed to place dosimetric films in (1) horizontal (xy) and (2) vertical (xz) planes. Specific cylindrical adaptors were designed to place thimble ionization chamber inside phantom for point dose recording along xz axis. EBT3 Gafchromic films were used to analyze and map radiation field. The focal precision test was performed using 4 mm collimator shot in phantom to check radiological accuracy of treatment. The phantom head position within the Extend™ frame was estimated using encoded aperture measurement of repositioning check tool (RCT). For treatment verification, the phantom with inserts for film and ion chamber was scanned in reference treatment position using X-ray computed tomography (CT) machine and acquired stereotactic images were transferred into Leksell Gammaplan (LGP). A patient treatment plan with hypo-fractionated regimen was delivered and identical fractions were compared using EBT3 films and in-house MATLAB codes. Results: RCT measurement showed an overall positional accuracy of 0.265 mm (range 0.223 mm–0.343 mm). Gamma index analysis across fractions exhibited close agreement between LGP and film