WorldWideScience

Sample records for pgnaa set-up developed

  1. Prompt gamma radiation activation analysis (PGNAA)

    International Nuclear Information System (INIS)

    Ovalle, M; Navarro, G; Henriquez, O; Andonie, A; Pereda, C

    2003-01-01

    This Nuclear technique (PGNAA) uses thermal neutron beams produced on nuclear reactor. The RECH-1 reactor, has this facility since several years. In this work we show the development of a set of measurements made with the final propose to obtain a set of future standards to be used on solid samples quantification. It is also described the most used quantification methods based on this technique. It is also wanted to remark that this technique allows to show the natural elements isotopic composition. As an example we show a natural Ni study (Au)

  2. Monte Carlo study of a flexible device for in situ PGNAA using 241Am-Be source: application to total chlorine determination

    International Nuclear Information System (INIS)

    Khelifi, R.; Bode, P.

    2016-01-01

    MCNP5 has been used to optimize the design of a Prompt gamma ray neutron activation analysis (PGNAA) facility, which was subsequently constructed for quantification of total chlorine in water to simulate neutron transport from an 241 AmBe source into a PGNAA set-up. Modeling calculations were performed to optimize the experimental set-up for Cl measurements in water. The optimization with MCNP5 was focused on maximizing the thermal neutrons flux which leads to improving the gamma prompt production after neutron capture in a water sample. The influence of dimensions and materials for the neutron collimation as well as the dimensions of the sample together were studied. A PGNAA facility with an 241 AmBe neutron source was built based on the optimized configuration and used to determine chlorine concentration. Measured values of the chlorine count rate were plotted versus the NaCl in water. The count rate versus amount of chlorine show a good coefficient of correlation of the linear fit. The result permits PGNAA to be a valuable diagnostic tool for getting an indication of the salinity contamination of water. (author)

  3. Identification system for chemical warfare agents with PGNAA method

    International Nuclear Information System (INIS)

    Wang Bairong; Yin Guanghua; Yang Zhongpin

    2007-01-01

    The principle and the experimental commanding of Chemical warfare Agents Identification with PGNAA method are discussed in this paper. The choosing of detector, neutron source and the data processing method are detailed. Finally, a set of experimental instruments composed of Cf-232 and BGO detector is developed based on this theory discussed above. (authors)

  4. A identification system for chemical warfare agents with PGNAA method

    International Nuclear Information System (INIS)

    Wang Bairong; Yin Guanghua; Yang Zhongping

    2006-01-01

    The principle and the experimental commanding of Chemical warfare Agents Identification with PGNAA method are discussed in this paper. The choosing of Detector, neutron source and the data processing method are detailed. Finally, a set of experimental instruments composed of Cf-232 and BGO detector is developed based on the theory discussed above. (authors)

  5. Monte Carlo simulations for design of the KFUPM PGNAA facility

    CERN Document Server

    Naqvi, A A; Maslehuddin, M; Kidwai, S

    2003-01-01

    Monte Carlo simulations were carried out to design a 2.8 MeV neutron-based prompt gamma ray neutron activation analysis (PGNAA) setup for elemental analysis of cement samples. The elemental analysis was carried out using prompt gamma rays produced through capture of thermal neutrons in sample nuclei. The basic design of the PGNAA setup consists of a cylindrical cement sample enclosed in a cylindrical high-density polyethylene moderator placed between a neutron source and a gamma ray detector. In these simulations the predominant geometrical parameters of the PGNAA setup were optimized, including moderator size, sample size and shielding of the detector. Using the results of the simulations, an experimental PGNAA setup was then fabricated at the 350 kV Accelerator Laboratory of this University. The design calculations were checked experimentally through thermal neutron flux measurements inside the PGNAA moderator. A test prompt gamma ray spectrum of the PGNAA setup was also acquired from a Portland cement samp...

  6. Effect of Filter Arrangement in PGNAA Collimator Design for TRIGA Reactor: A MCNPX Study

    International Nuclear Information System (INIS)

    Hanafi Ithnin; Mohamad Hairie Rabir; Roslan Yahya

    2016-01-01

    Prompt Gamma Neutron Activation Analysis, PGNAA is known as a very powerful nuclear instrument in elemental analysis. The combination of volumetric measurement, range of elemental that can be detected and non-destructive nature of this technique, makes it very useful in analyzing various samples. In order to elevate the PGNAA system, it demand high thermal neutron flux to ensure the neutron activation and intensity of the produced prompt gamma is satisfactory. In the aim to develop reactor based PGNAA system, computer software, MCNPX is used as a tool to simulate the best production of thermal neutron. Hence, provide valuable information for optimizing collimator designs of the PGNAA system. Therefore in this study, different arrangement of bismuth and sapphire filter were made to evaluate its effect on the production of thermal neutron flux. The result shows, different filters arrangement in the collimator influenced the production of neutron flux. Ultimately the result of this study will be a significant contribution to the knowledge and a great assist in designing collimator for TRIGA reactor based PGNAA system. (author)

  7. Validity test of design calculations of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.

    2004-01-01

    A rectangular moderator has been designed for the prompt gamma ray neutron activation analysis (PGNAA) setup at King Fahd University of Petroleum and Minerals (KFUPM) to analyze Portland cement samples. The design of the moderator assembly was obtained using Monte Carlo calculations. The design calculations of the new rectangular moderator of the KFUPM PGNAA setup have been verified experimentally through prompt gamma ray yield measurement as a function of the front moderator thickness. In this study the yield of the 3.54 and 4.94 MeV prompt gamma rays from silicon in a soil sample was measured as a function of thickness of the front moderator of the rectangular moderator. The experimental results were compared with the results of the Monte Carlo simulations. A good agreement has been achieved between the experimental results and the results of the calculations. The experimental results have provided useful information about the PGNAA setup performance, neutron moderation, and gamma ray attenuation in the PGNAA sample

  8. Measurement of lime/silica ratio in concrete using PGNAA technique

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-12-01

    Prompt gamma neutron activation analysis (PGNAA) technique has been used to determine lime/silica ratio in concrete samples using an accelerator-based PGNAA facility. The ratio was determined from the measured yield of 6.42 MeV prompt {gamma}-rays of calcium and 4.93 MeV {gamma}-rays of silicon from the six concrete samples. The experimental results were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the two. The study has demonstrated successful use of the accelerator-based PGNAA setup in non-destructive analysis of the concrete samples.

  9. Feasibility study of application of Prompt Gamma Neutron Activation Analysis (PGNAA) method in TRIGA IPR-R1 reactor

    International Nuclear Information System (INIS)

    Guerra, Bruno Teixeira

    2016-01-01

    The TRIGA Mark I IPR-R1 research reactor is located at Nuclear Technology Development Centre (CDTN), Brazilian Commission for Nuclear Energy (CNEN), in Belo Horizonte, Brazil. The reactor operates at 100 kW but the core configuration allows the increasing of the power up to 250 kW. It has been applied research, training and radioisotopes production. The establishment of the Prompt Gamma Neutron Activation Analysis (PGNAA) method at the TRIGA IPR-R1 reactor will significantly increase the types of matrices analysed as well as the number of chemical elements. Additionally it will complement the neutron activation analysis. This work presents a proposed design of a PGNAA facility to be installed at the TRIGA IPR-R1. The proposed design is based on a tube as a neutron guide from the reactor core, inside the reactor pool, 6 m below the room’s level where shall be located the rack containing the set sample/detector/shielding. Thus, the aim of this study is to verify the feasibility to establish the PGNAA method in IPR-R1 through theoretical study applying the Monte Carlo code. The feasibility of establishing the PGAA method at the IPR-R1 installations was evaluated through of the calculations of neutron flux, radioactive capture reaction rates and detection limits for some isotopes. According to the obtained results, it can be concluded that is possible to establish the PGAA method at the IPR-R1 reactor, even with some restrictions in its theoretical design calculated by MCNP. (author)

  10. Feasibility study of application of Prompt Gamma Neutron Activation Analysis (PGNAA) method in TRIGA IPR-R1 reactor; Estudo da viabilidade de aplicação do método Prompt Gamma Neutron Activation Analysis (PGNAA) no reator TRIGA IPR-R1

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Bruno Teixeira

    2016-07-01

    The TRIGA Mark I IPR-R1 research reactor is located at Nuclear Technology Development Centre (CDTN), Brazilian Commission for Nuclear Energy (CNEN), in Belo Horizonte, Brazil. The reactor operates at 100 kW but the core configuration allows the increasing of the power up to 250 kW. It has been applied research, training and radioisotopes production. The establishment of the Prompt Gamma Neutron Activation Analysis (PGNAA) method at the TRIGA IPR-R1 reactor will significantly increase the types of matrices analysed as well as the number of chemical elements. Additionally it will complement the neutron activation analysis. This work presents a proposed design of a PGNAA facility to be installed at the TRIGA IPR-R1. The proposed design is based on a tube as a neutron guide from the reactor core, inside the reactor pool, 6 m below the room’s level where shall be located the rack containing the set sample/detector/shielding. Thus, the aim of this study is to verify the feasibility to establish the PGNAA method in IPR-R1 through theoretical study applying the Monte Carlo code. The feasibility of establishing the PGAA method at the IPR-R1 installations was evaluated through of the calculations of neutron flux, radioactive capture reaction rates and detection limits for some isotopes. According to the obtained results, it can be concluded that is possible to establish the PGAA method at the IPR-R1 reactor, even with some restrictions in its theoretical design calculated by MCNP. (author)

  11. Bulk - Samples gamma-rays activation analysis (PGNAA) with Isotopic Neutron Sources

    International Nuclear Information System (INIS)

    HASSAN, A.M.

    2009-01-01

    An overview is given on research towards the Prompt Gamma-ray Neutron Activation Analysis (PGNAA) of bulk-samples. Some aspects in bulk-sample PGNAA are discussed, where irradiation by isotopic neutron sources is used mostly for in-situ or on-line analysis. The research was carried out in a comparative and/or qualitative way or by using a prior knowledge about the sample material. Sometimes we need to use the assumption that the mass fractions of all determined elements add up to 1. The sensitivity curves are also used for some elements in such complex samples, just to estimate the exact percentage concentration values. The uses of 252 Cf, 241 Arn/Be and 239 Pu/Be isotopic neutron sources for elemental investigation of: hematite, ilmenite, coal, petroleum, edible oils, phosphates and pollutant lake water samples have been mentioned.

  12. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    CERN Document Server

    Al-Jarallah, M I; Fazal-Ur-Rehman; Abu-Jarad, F A

    2002-01-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has bee...

  13. Fast and thermal neutron intensity measurements at the KFUPM PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I.; Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman; Abu-jarad, F

    2002-10-01

    Fast and thermal neutron intensity distributions have been measured at an accelerator based prompt gamma ray neutron activation analysis (PGNAA) setup. The setup is built at the 350 keV accelerator laboratory of King Fahd University of Petroleum and Minerals (KFUPM). The setup is mainly designed to carry out PGNAA elemental analysis via thermal neutron capture. In this study relative intensity of fast and thermal neutrons was measured as a function of the PGNAA moderator assembly parameters using nuclear track detectors (NTDs). The relative intensity of the neutrons was measured inside the sample region as a function of front moderator thickness as well as sample length. Measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The pulsed deuteron beam with 5 ns pulse width and 30 kHz frequency was used to produce neutrons. Experimental results were compared with results of Monte Carlo design calculations of the PGNAA setup. A good agreement has been found between the experimental results and the calculations.

  14. Detection of unexploded ordnance by PGNAA based borehole-logging

    International Nuclear Information System (INIS)

    John Kettler; RWTH-Aachen University, Aachen; Eric Mauerhofer; Marco Steinbusch

    2013-01-01

    The performance of a borehole-logging system, based on prompt-gamma-neutron-activation-analysis (PGNAA), for explosive detection was studied by Monte-Carlo simulations. The prompt gamma of nitrogen, which is a constituent of common explosive, was used to identify the unexploded ordnance (UXO). Our results show that the minimum counting time depends on the soil moisture, the cladding thickness and the explosive composition. In conjunction with the standard detection by magnetometry, the PGNAA is a promising analytical technique for definitive identification of deep buried UXOs. (author)

  15. Sample to moderator volume ratio effects in neutron yield from a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)

    2007-02-15

    Performance of a prompt gamma ray neutron activation analysis (PGNAA) setup depends upon thermal neutron yield at the PGNAA sample location. For a moderator, which encloses a sample, thermal neutron intensity depends upon the effective moderator volume excluding the void volume due to sample volume. A rectangular moderator assembly has been designed for the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA setup. The thermal and fast neutron yield has been measured inside the sample cavity as a function of its front moderator thickness using alpha particle tracks density and recoil proton track density inside the CR-39 nuclear track detectors (NTDs). The thermal/fast neutron yield ratio, obtained from the alpha particle tracks density to proton tracks density ratio in the NTDs, shows an inverse correlation with sample to moderator volume ratio. Comparison of the present results with the previously published results of smaller moderators of the KFUPM PGNAA setup confirms the observation.

  16. Monte Carlo aided treatments of the nonlinear inverse PGNAA measurement problem for various continuous on-line applications

    International Nuclear Information System (INIS)

    Gardner, R.P.; Guo, P.; Sood, A.; Mayo, C.W.; Dobbs, C.L.

    1998-01-01

    A review of our work on the application of the PGNAA method as applied to five industrial applications is given. Some introductory material is first given on the importance and use of Monte Carlo simulation in this area, some comments on the place of PGNAA in elemental analysis, and a brief description of the Monte Carlo - Library Least-Squares (MCLLS) approach to the nonlinear inverse PGNAA analysis problem. Then the applications of PGNAA are discussed for: (1) on-line bulk coal analysis, (2) nuclear oil well logging, (3) vitrified waste, (4) the analysis of sodium and aluminium in 'green liquor' in the presence of chlorine, and (5) the conveyor belt sorting of aluminum alloy samples. It is concluded that PGNAA is a rapidly emerging important new technology and measurement approach. (author)

  17. Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code

    International Nuclear Information System (INIS)

    Oliveira, Carlos; Salgado, Jose

    1998-01-01

    In large samples, the γ-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of the influence of geometry arrangements and structural materials on a PGNAA system performance for cement raw materials analysis. Appl. Radiat. Isot. (accepted); Oliveira, C., Salgado, J. and Leitao, F. (1997b) Density and water content corrections in the gamma count rate of a PGNAA system for cement raw material analysis using the MCNP code. Appl. Radiat. Isot. (accepted).]. It reports on the influence of the density, mass water content and thickness on the calibration curves of the PGNAA system. The MCNP-4A code, running in a Pentium-PC and in a DEC workstation, was used to simulate the PGNAA configuration system

  18. Technical Aspect for Operating Portable Prompt Gamma Neutron Activation Analysis (PGNAA) on Terengganu Inscribed Stone

    International Nuclear Information System (INIS)

    Rasif Mohd Zain; Hearie Hassan; Roslan Yahya

    2015-01-01

    Prompt Gamma Neutron Activation analysis (PGNAA) is a type of neutron activation analysis which can determined element with nearly no gamma ray decay after being irradiated by neutron sourced. Thus, element that cannot be determined by the conventional NAA for example H, B, N, Si and Cd, can be determine by PGNAA. This paper focuses on the technical working procedure for operating portable PGNAA in field work. The device is designed as a portable non-destructive investigation tool applying an isotopic neutron source (Cf-252) and a gamma-ray spectroscopy system for in-situ investigation. The studied have been carried out on Terengganu inscribed stone at Terengganu State Museum. (author)

  19. Neutron moderation in a bulk sample and its effects on PGNAA setup geometry

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Naqvi, A.A.; Fazal-ur-Rehman,; Maselehuddin, M.; Abu-Jarad, F.; Raashid, M.

    2003-01-01

    In a prompt gamma ray neutron activation analysis (PGNAA) setup, the neutron moderation in the bulk sample also plays a key role. This can even dominate the thermalization effects of the external moderator in some cases. In order to study the neutron moderation effect in the bulk sample, moderators with two different sizes of the sample were tested at the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA facility. In these tests, the thermal neutron relative intensity and prompt gamma ray yield from the two moderators were measured using nuclear track detectors (NTDs) and NaI detector, respectively. As predicted by Monte Carlo simulations, the measured intensity of thermal neutron inside the large sample cavity due to the external moderator was smaller than that from the smaller sample cavity. Due to its larger size, additional thermalization of neutrons will take place in the larger sample. In spite of smaller thermal neutron yield from the external moderator at the large sample location, higher yield of the prompt gamma ray was observed as compared to that from the smaller sample. This confirms the significance of neutron moderation effects in the bulk sample and can thereby affect the PGNAA geometry size. This allows larger samples in conjunction with smaller moderators in the PGNAA setup

  20. Neutron moderation in a bulk sample and its effects on PGNAA setup geometry

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Naqvi, A.A.; Fazal-ur-Rehman,; Maselehuddin, M.; Abu-Jarad, F.; Raashid, M

    2003-06-01

    In a prompt gamma ray neutron activation analysis (PGNAA) setup, the neutron moderation in the bulk sample also plays a key role. This can even dominate the thermalization effects of the external moderator in some cases. In order to study the neutron moderation effect in the bulk sample, moderators with two different sizes of the sample were tested at the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA facility. In these tests, the thermal neutron relative intensity and prompt gamma ray yield from the two moderators were measured using nuclear track detectors (NTDs) and NaI detector, respectively. As predicted by Monte Carlo simulations, the measured intensity of thermal neutron inside the large sample cavity due to the external moderator was smaller than that from the smaller sample cavity. Due to its larger size, additional thermalization of neutrons will take place in the larger sample. In spite of smaller thermal neutron yield from the external moderator at the large sample location, higher yield of the prompt gamma ray was observed as compared to that from the smaller sample. This confirms the significance of neutron moderation effects in the bulk sample and can thereby affect the PGNAA geometry size. This allows larger samples in conjunction with smaller moderators in the PGNAA setup.

  1. The background influence of cadmium detection in saline water using PGNAA technique

    International Nuclear Information System (INIS)

    Daqian Hei; Zhou Jiang; Hongtao Wang; Jiatong Li

    2016-01-01

    In order to solve the background influence of cadmium detection in saline water using prompt gamma neutron activation analysis (PGNAA) technique, a series experiments have been designed and carried out. Furthermore, a method based on internal standard was used to correct the neutron self-shielding effect, and the background influence has been decreased sequentially. The results showed a good linear relationship between the characteristic peak counts and the concentrations of cadmium after the neutron self-shielding correction. And in the detection of saline water by PGNAA technique, the proposed methodology can be used to reduce the influence of background with the self-shielding effect correction. (author)

  2. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.; Maslehuddin, M.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.

    2010-01-01

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the γ-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring γ-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  3. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-04-15

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the {gamma}-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring {gamma}-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  4. The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron.

    Science.gov (United States)

    Fantidis, J G; Nicolaou, G E; Potolias, C; Vordos, N; Bandekas, D V

    A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources ( 241 Am/Be, 252 Cf, 241 Am/B, and DT neutron generator). Among the different systems the 252 Cf neutron based PGNAA system has the best performance.

  5. Effect of silica fume addition on the PGNAA measurement of chlorine in concrete

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Maslehuddin, M.; Garwan, M.A.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.; Khateeb-ur-Rehman

    2010-01-01

    Pozzolanic materials, such as fly ash (FA), silica fume (SF), and blast furnace slag (BFS) are added to Portland cement in concrete to prevent reinforcement steel corrosion in concrete. Further preventive measure against reinforcement steel corrosion require monitoring of chloride salts concentration in concrete using non-destructive techniques, such as the prompt gamma-ray neutron activation analysis (PGNAA) technique. Due to interferences between gamma-rays from chlorine and calcium in PGNAA technique, detection limit of chlorine in concrete strongly depends upon calcium concentration in concrete. SF mainly contains silica and its addition to cement concrete reduces overall concentration of calcium in concrete. This may result in an improvement in detection limit of chlorine in SF-based concrete in PGNAA studies. Particularly for chlorine detection using 6.11 and 6.62 MeV prompt gamma-rays that strongly interfere with 6.42 MeV prompt gamma-rays from calcium. In this study, SF was added to Portland cement to prevent concrete reinforcement steel from corrosion. The chlorine concentration in SF cement concrete specimens containing 0.2-3.0 wt% chlorine was measured through yield of 1.16, 1.95, 6.11, 6.62, 7.41, 7.79, and 8.58 MeV chlorine gamma-rays using PGNAA technique. An excellent agreement was noted between the experimental yield of the prompt gamma-rays and the gamma-ray yield calculated through the Monte Carlo simulations. Further the minimum detectable concentration (MDC) of chlorine in SF cement concrete was calculated and compared with the MDC values of chlorine in plain concrete and concrete mixed with fly ash cement. The MDC of chlorine in SF-based concrete through 6.11 MeV, and 6.62 MeV chlorine gamma-rays was found to be improved as compared to those in plain concrete and concrete mixed with fly ash cement.

  6. Effect of silica fume addition on the PGNAA measurement of chlorine in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Maslehuddin, M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M.; Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-03-15

    Pozzolanic materials, such as fly ash (FA), silica fume (SF), and blast furnace slag (BFS) are added to Portland cement in concrete to prevent reinforcement steel corrosion in concrete. Further preventive measure against reinforcement steel corrosion require monitoring of chloride salts concentration in concrete using non-destructive techniques, such as the prompt gamma-ray neutron activation analysis (PGNAA) technique. Due to interferences between gamma-rays from chlorine and calcium in PGNAA technique, detection limit of chlorine in concrete strongly depends upon calcium concentration in concrete. SF mainly contains silica and its addition to cement concrete reduces overall concentration of calcium in concrete. This may result in an improvement in detection limit of chlorine in SF-based concrete in PGNAA studies. Particularly for chlorine detection using 6.11 and 6.62 MeV prompt gamma-rays that strongly interfere with 6.42 MeV prompt gamma-rays from calcium. In this study, SF was added to Portland cement to prevent concrete reinforcement steel from corrosion. The chlorine concentration in SF cement concrete specimens containing 0.2-3.0 wt% chlorine was measured through yield of 1.16, 1.95, 6.11, 6.62, 7.41, 7.79, and 8.58 MeV chlorine gamma-rays using PGNAA technique. An excellent agreement was noted between the experimental yield of the prompt gamma-rays and the gamma-ray yield calculated through the Monte Carlo simulations. Further the minimum detectable concentration (MDC) of chlorine in SF cement concrete was calculated and compared with the MDC values of chlorine in plain concrete and concrete mixed with fly ash cement. The MDC of chlorine in SF-based concrete through 6.11 MeV, and 6.62 MeV chlorine gamma-rays was found to be improved as compared to those in plain concrete and concrete mixed with fly ash cement.

  7. Verification of design calculations of a PGNAA setup using nuclear track ejectors

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman,; Nagadi, .M.; Maslehuddin, M.; Khateeb-ur-Rehman; Kidwai, S

    2004-02-01

    A rectangular moderator assembly has been designed for the PGNAA setup at ing Fahd University of Petroleum and Minerals (KFUPM). The design calculations of the rectangular moderator, which were obtained through Monte Carlo simulation, have been verified experimentally through thermal neutron field measurement using CR-39 nuclear track detectors (NTDs). These measurements were carried out at the KFUPM 350 keV accelerator using 2.8 MeV pulsed neutron beam from D(d,n) reaction. The thermal neutron yield was measured inside the sample volume of the rectangular moderator by two NTDs fixed at back and front end of the sample cavity. The good agreement between he experimental results and the results of the calculations shows useful application of NTDs in verification of design calculations of a PGNAA setup.

  8. The MCNP Simulation of a PGNAA System at TRR-1/M1

    Science.gov (United States)

    Sangaroon, S.; Ratanatongchai, W.; Picha, R.; Khaweerat, S.; Channuie, J.

    2017-06-01

    The prompt-gamma neutron activation analysis system (PGNAA) has been installed at Thai Research Reactor-1/Modified 1 (TRR-1/M1) since 1999. The purpose of the system is for elemental and isotopic analyses. The system mainly consists of a series of the moderator and collimator, neutron and gamma-ray shielding and the HPGe detector. In this work, the condition of the system is carried out based on the Monte Carlo method using Monte Carlo N-Particle transport code and the experiment. The flux ratios (Φthermal/Φepithermal and Φthermal/Φfast) and thermal neutron flux have been obtained. The simulated prompt gamma rays of the Portland cement sample have been carried out. The simulation provides significant contribution in upgrading the PGNAA station to be available in various applications.

  9. Investigation of the PGNAA using the LaBr3 scintillation detector

    International Nuclear Information System (INIS)

    Favalli, A.; Mehner, H.-C.; Ciriello, V.; Pedersen, B.

    2008-01-01

    Full text: The Joint Research Centre of the European Commission develops instrumentation and analysis methods for the non-destructive assay of nuclear materials and for detection of contraband materials. In relation to this, a new experimental device was designed and constructed in the laboratory of the Institute for the Protection and the Security of the Citizen (IPSC), Nuclear Safeguards Unit. The device, called the Pulsed Neutron Interrogation Test Assembly (PUNITA), incorporates a pulsed (D-T) neutron generator. In the PUNITA facility we study the methods applying the detection of characteristic gamma rays subsequent to neutron irradiation. This includes the detection of prompt gamma rays from neutron inelastic scattering and neutron capture. The gamma ray energy from these reactions is characteristic for the target elements present in the sample. For the detection of materials such the device employs gamma detectors for characteristic prompt gamma rays. The gamma detectors include HPGe detectors and scintillation detectors based on the Lanthanum Bromide crystal. This new scintillation detector is particularly suited for the detection of activation gamma rays in the MeV range. To prepare the experimental and theoretical considerations with PUNITA facility some experiments have been carried out by means of conventional neutron sources. This work enables both to study gamma-ray spectra due to the prompt gamma rays emitted after the thermal neutron capture, to evaluate the performance of the new type of scintillation detectors for PGNAA applications. The paper presents and discusses the set-up employed and the results obtained so far

  10. 350 keV accelerator based PGNAA setup to detect nitrogen in bulk samples

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A., E-mail: aanaqvi@kfupm.edu.sa [Department of Physics and King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Matouq, Faris A.; Khiari, F.Z.; Gondal, M.A.; Rehman, Khateeb-ur [Department of Physics and King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Isab, A.A. [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Raashid, M.; Dastageer, M.A. [Department of Physics and King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2013-11-21

    Nitrogen concentration was measured in explosive and narcotics proxy material, e.g. anthranilic acid, caffeine, melamine, and urea samples, bulk samples through thermal neutron capture reaction using 350 keV accelerator based prompt gamma ray neutron activation (PGNAA) setup. Intensity of 2.52, 3.53–3.68, 4.51, 5.27–5.30 and 10.38 MeV prompt gamma rays of nitrogen from the bulk samples was measured using a cylindrical 100 mm×100 mm (diameter×height ) BGO detector. Inspite of interference of nitrogen gamma rays from bulk samples with capture prompt gamma rays from BGO detector material, an excellent agreement between the experimental and calculated yields of nitrogen gamma rays has been obtained. This is an indication of the excellent performance of the PGNAA setup for detection of nitrogen in bulk samples.

  11. 350 keV accelerator based PGNAA setup to detect nitrogen in bulk samples

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Al-Matouq, Faris A.; Khiari, F.Z.; Gondal, M.A.; Rehman, Khateeb-ur; Isab, A.A.; Raashid, M.; Dastageer, M.A.

    2013-01-01

    Nitrogen concentration was measured in explosive and narcotics proxy material, e.g. anthranilic acid, caffeine, melamine, and urea samples, bulk samples through thermal neutron capture reaction using 350 keV accelerator based prompt gamma ray neutron activation (PGNAA) setup. Intensity of 2.52, 3.53–3.68, 4.51, 5.27–5.30 and 10.38 MeV prompt gamma rays of nitrogen from the bulk samples was measured using a cylindrical 100 mm×100 mm (diameter×height ) BGO detector. Inspite of interference of nitrogen gamma rays from bulk samples with capture prompt gamma rays from BGO detector material, an excellent agreement between the experimental and calculated yields of nitrogen gamma rays has been obtained. This is an indication of the excellent performance of the PGNAA setup for detection of nitrogen in bulk samples

  12. 350 keV accelerator based PGNAA setup to detect nitrogen in bulk samples

    Science.gov (United States)

    Naqvi, A. A.; Al-Matouq, Faris A.; Khiari, F. Z.; Gondal, M. A.; Rehman, Khateeb-ur; Isab, A. A.; Raashid, M.; Dastageer, M. A.

    2013-11-01

    Nitrogen concentration was measured in explosive and narcotics proxy material, e.g. anthranilic acid, caffeine, melamine, and urea samples, bulk samples through thermal neutron capture reaction using 350 keV accelerator based prompt gamma ray neutron activation (PGNAA) setup. Intensity of 2.52, 3.53-3.68, 4.51, 5.27-5.30 and 10.38 MeV prompt gamma rays of nitrogen from the bulk samples was measured using a cylindrical 100 mm×100 mm (diameter×height ) BGO detector. Inspite of interference of nitrogen gamma rays from bulk samples with capture prompt gamma rays from BGO detector material, an excellent agreement between the experimental and calculated yields of nitrogen gamma rays has been obtained. This is an indication of the excellent performance of the PGNAA setup for detection of nitrogen in bulk samples.

  13. The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)

    Energy Technology Data Exchange (ETDEWEB)

    Pinault, Jean-Louis [IAEA Expert, 96 rue du Port David, 45370 Dry (France)], E-mail: jeanlouis_pinault@hotmail.fr; Solis, Jose [Instituto Peruano de Energia Nuclear, Av. Canada No. 1470, San Borja, Lima 41 (Peru)

    2009-04-15

    The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and on-line analysis on conveyor belt of raw materials.

  14. Improving the safety of a body composition analyser based on the PGNAA method

    Energy Technology Data Exchange (ETDEWEB)

    Miri-Hakimabad, Hashem; Izadi-Najafabadi, Reza; Vejdani-Noghreiyan, Alireza; Panjeh, Hamed [FUM Radiation Detection And Measurement Laboratory, Ferdowsi University of Mashhad (Iran, Islamic Republic of)

    2007-12-15

    The {sup 252}Cf radioisotope and {sup 241}Am-Be are intense neutron emitters that are readily encapsulated in compact, portable and sealed sources. Some features such as high flux of neutron emission and reliable neutron spectrum of these sources make them suitable for the prompt gamma neutron activation analysis (PGNAA) method. The PGNAA method can be used in medicine for neutron radiography and body chemical composition analysis. {sup 252}Cf and {sup 241}Am-Be sources generate not only neutrons but also are intense gamma emitters. Furthermore, the sample in medical treatments is a human body, so it may be exposed to the bombardments of these gamma-rays. Moreover, accumulations of these high-rate gamma-rays in the detector volume cause simultaneous pulses that can be piled up and distort the spectra in the region of interest (ROI). In order to remove these disadvantages in a practical way without being concerned about losing the thermal neutron flux, a gamma-ray filter made of Pb must be employed. The paper suggests a relatively safe body chemical composition analyser (BCCA) machine that uses a spherical Pb shield, enclosing the neutron source. Gamma-ray shielding effects and the optimum radius of the spherical Pb shield have been investigated, using the MCNP-4C code, and compared with the unfiltered case, the bare source. Finally, experimental results demonstrate that an optimised gamma-ray shield for the neutron source in a BCCA can reduce effectively the risk of exposure to the {sup 252}Cf and {sup 241}Am-Be sources.

  15. Aplicación del análisis por activación neutrónica de gammas inmediatos (PGNAA) para el perfilaje de perforaciones de voladura en una cantera de Cementos Lima: Reporte Preliminar

    OpenAIRE

    Zanabria, César; Medina, Rafael; Gilvonio, Leoncio; Munive, Marco; Baltuano, Oscar; Solís, José

    2008-01-01

    El análisis por activación neutrónica de gammas inmediatos (PGNAA) es una técnica de análisis elemental que se usa en la industria. Estamos investigando la factibilidad de la aplicación de la técnica PGNAA en la caracterización elemental de las perforaciones de voladura de la cantera de Atocongo de Cementos Lima. The prompt gamma neutron activation (PGNAA) is a technique that has been used in the industry. We are investigating the feasibility of the PGNAA technique for elemental characteri...

  16. Calibration of A Prompt Gamma Neutron Activation Analysis (PGNAA) Facility: Experience at the Oregon State University TRIGA Reactor

    International Nuclear Information System (INIS)

    Norlida Yussup

    2011-01-01

    A prompt gamma neutron activation analysis (PGNAA) facility at Oregon State University (OSU) TRIGA reactor has been built in year 2008 and been operated since then. PGNAA is a technique used to determine the presence and quantity of trace elements such as boron, hydrogen and carbon which are more difficult to detect with other neutron analysis method. A calibration is essential to ensure the system works as required and the output is valid and reliable. The calibration was carried out by using Standard Reference Material (SRM). Besides, background data was also acquired for comparisons and analysis. The results are analyzed and discussed in this paper. (author)

  17. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  18. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  19. Performance tests of external moderators of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M.

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt γ-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt γ-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt γ-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt γ-rays

  20. Performance tests of external moderators of a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt {gamma}-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt {gamma}-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt {gamma}-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt {gamma}-rays.

  1. K0-PGNAA of pollutants in aqueous samples using MCNP code

    International Nuclear Information System (INIS)

    Hamid, A.; Shahbunder, H.

    2014-01-01

    Prompt γ-neutron activation analysis (PGNAA) using the k 0 method by employing the 1951.1 keV γ-line of the 35 Cl(n, γ) 36 Cl thermal neutron reaction as monostandard comparator was described. The method has been applied and evaluated using the anti-Compton prompt γ-ray neutron activation analysis facility using 252 Cf neutron source with a neutron flux of 6.16·10 6 n· cm -2 · s -1 . A well-type HPGe detector as the main detector surrounded by NaI(Tl) guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The properties of neutron flux were determined by MCNP code calculations. In order to determine the efficiency curve of an HPGe detector, the prompt γ-rays from chlorine were used and an exponential curve was fitted. AC-PGNAA method has been used for the determination of high neutron absorbing elements like Cd, Sm and Gd as well as 20 light and heavy elements (Na, Mg, Al, Si, P, K, Ca, Ti, V, Mn, Sc, Fe, Co, Zn, La, Rb, Cs, As and Th) in standard reference materials (IAEA, Soil-7) and ten sediment samples collected from El-Manzala lake in northern part of Egypt. The reference material IAEA, Soil-7 was analyzed for data validation and good agreement between the experimental values and the certified values have been obtained

  2. k0-PGNAA of pollutants in aqueous samples using MCNP code

    Directory of Open Access Journals (Sweden)

    A. Hamid

    2014-03-01

    Full Text Available Prompt γ-neutron activation analysis (PGNAA using the k0 method by employing the 1951.1 keV γ-line of the 35Cl(n, γ36Cl thermal neutron reaction as monostandard comparator was described. The method has been applied and evaluated using the anti-Compton prompt γ-ray neutron activation analysis facility using 252Cf neutron source with a neutron flux of 6.16 · 106 n · cm-2 · s-1. A well-type HPGe detector as the main detector surrounded by NaI(Tl guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The properties of neutron flux were determined by MCNP code calculations. In order to determine the efficiency curve of an HPGe detector, the prompt γ-rays from chlorine were used and an exponential curve was fitted. AC-PGNAA method has been used for the determination of high neutron absorbing elements like Cd, Sm and Gd as well as 20 light and heavy elements (Na, Mg, Al, Si, P, K, Ca, Ti, V, Mn, Sc, Fe, Co, Zn, La, Rb, Cs, As and Th in standard reference materials (IAEA, Soil-7 and ten sediment samples collected from El-Manzala lake in northern part of Egypt. The reference material IAEA, Soil-7 was analyzed for data validation and good agreement between the experimental values and the certified values have been obtained.

  3. Detection limits of pollutants in water for PGNAA using Am-Be source

    International Nuclear Information System (INIS)

    Khelifi, R.; Amokrane, A.; Bode, P.

    2007-01-01

    A basic PGNAA facility with an Am-Be neutron source is described to analyze the pollutants in water. The properties of neutron flux were determined by MCNP calculations. In order to determine the efficiency curve of a HPGe detector, the prompt-gamma rays from chlorine were used and an exponential curve was fitted. The detection limits for typical water sample are also estimated using the statistical fluctuations of the background level in the areas of recorded the prompt-gamma spectrum

  4. Measurement of nitrogen in the body using a commercial PGNAA system--phantom experiments.

    Science.gov (United States)

    Chichester, D L; Empey, E

    2004-01-01

    An industrial prompt-gamma neutron activation analysis (PGNAA) system, originally designed for the real-time elemental analyses of bulk coal on a conveyor belt, has been studied to examine the feasibility of using such a system for body composition analysis. Experiments were conducted to measure nitrogen in a simple, tissue equivalent phantom comprised of 2.7 wt% of nitrogen. The neutron source for these experiments was 365 MBq (18.38 microg) of 252Cf located within an engineered low Z moderator and it yielded a dose rate in the measurement position of 3.91 mSv/h; data were collected using a 2780 cm(3) NaI(Tl) cylindrical detector with a digital signal processor and a 512 channel MCA. Source, moderator and detector geometries were unaltered from the system's standard configuration, where they have been optimized for considerations such as neutron thermalization, measurement sensitivity and uniformity, background radiation and external dose minimization. Based on net counts in the 10.8 MeV PGNAA nitrogen photopeak and its escape peaks the dose dependent nitrogen count rate was 11,600 counts/mSv with an uncertainty of 3.0% after 0.32 mSv (4.9 min), 2.0% after 0.74 mSv (11.4 min) and 1.0% after 3.02 mSv (46.4 min).

  5. Development of Data Acquisition Set-up for Steady-state Experiments

    Science.gov (United States)

    Srivastava, Amit K.; Gupta, Arnab D.; Sunil, S.; Khan, Ziauddin

    2017-04-01

    For short duration experiments, generally digitized data is transferred for processing and storage after the experiment whereas in case of steady-state experiment the data is acquired, processed, displayed and stored continuously in pipelined manner. This requires acquiring data through special techniques for storage and on-the-go viewing data to display the current data trends for various physical parameters. A small data acquisition set-up is developed for continuously acquiring signals from various physical parameters at different sampling rate for long duration experiment. This includes the hardware set-up for signal digitization, Field Programmable Gate Arrays (FPGA) based timing system for clock synchronization and event/trigger distribution, time slicing of data streams for storage of data chunks to enable viewing of data during acquisition and channel profile display through down sampling etc. In order to store a long data stream of indefinite/long time duration, the data stream is divided into data slices/chunks of user defined time duration. Data chunks avoid the problem of non-access of server data until the channel data file is closed at the end of the long duration experiment. A graphical user interface has been developed in Lab VIEW application development environment for configuring the data acquisition hardware and storing data chunks on local machine as well as at remote data server through Python for further data access. The data plotting and analysis utilities have been developed with Python software, which provides tools for further data processing. This paper describes the development and implementation of data acquisition for steady-state experiment.

  6. Status of software for PGNAA bulk analysis by the Monte Carlo - Library Least-Squares (MCLLS) approach

    International Nuclear Information System (INIS)

    Gardner, R.P.; Zhang, W.; Metwally, W.A.

    2005-01-01

    The Center for Engineering Applications of Radioisotopes (CEAR) has been working for about ten years on the Monte Carlo - Library Least-Squares (MCLLS) approach for treating the nonlinear inverse analysis problem for PGNAA bulk analysis. This approach consists essentially of using Monte Carlo simulation to generate the libraries of all the elements to be analyzed plus any other required libraries. These libraries are then used in the linear Library Least-Squares (LLS) approach with unknown sample spectra to analyze for all elements in the sample. The other libraries include all sources of background which includes: (1) gamma-rays emitted by the neutron source, (2) prompt gamma-rays produced in the analyzer construction materials, (3) natural gamma-rays from K-40 and the uranium and thorium decay chains, and (4) prompt and decay gamma-rays produced in the NaI detector by neutron activation. A number of unforeseen problems have arisen in pursuing this approach including: (1) the neutron activation of the most common detector (NaI) used in bulk analysis PGNAA systems, (2) the nonlinearity of this detector, and (3) difficulties in obtaining detector response functions for this (and other) detectors. These problems have been addressed by CEAR recently and have either been solved or are almost solved at the present time. Development of Monte Carlo simulation for all of the libraries has been finished except the prompt gamma-ray library from the activation of the NaI detector. Treatment for the coincidence schemes for Na and particularly I must be first determined to complete the Monte Carlo simulation of this last library. (author)

  7. UpSet: Visualization of Intersecting Sets

    Science.gov (United States)

    Lex, Alexander; Gehlenborg, Nils; Strobelt, Hendrik; Vuillemot, Romain; Pfister, Hanspeter

    2016-01-01

    Understanding relationships between sets is an important analysis task that has received widespread attention in the visualization community. The major challenge in this context is the combinatorial explosion of the number of set intersections if the number of sets exceeds a trivial threshold. In this paper we introduce UpSet, a novel visualization technique for the quantitative analysis of sets, their intersections, and aggregates of intersections. UpSet is focused on creating task-driven aggregates, communicating the size and properties of aggregates and intersections, and a duality between the visualization of the elements in a dataset and their set membership. UpSet visualizes set intersections in a matrix layout and introduces aggregates based on groupings and queries. The matrix layout enables the effective representation of associated data, such as the number of elements in the aggregates and intersections, as well as additional summary statistics derived from subset or element attributes. Sorting according to various measures enables a task-driven analysis of relevant intersections and aggregates. The elements represented in the sets and their associated attributes are visualized in a separate view. Queries based on containment in specific intersections, aggregates or driven by attribute filters are propagated between both views. We also introduce several advanced visual encodings and interaction methods to overcome the problems of varying scales and to address scalability. UpSet is web-based and open source. We demonstrate its general utility in multiple use cases from various domains. PMID:26356912

  8. Leadership set-up

    DEFF Research Database (Denmark)

    Thude, Bettina Ravnborg; Stenager, Egon; von Plessen, Christian

    2018-01-01

    . Findings: The study found that the leadership set-up did not have any clear influence on interdisciplinary cooperation, as all wards had a high degree of interdisciplinary cooperation independent of which leadership set-up they had. Instead, the authors found a relation between leadership set-up and leader...... could influence legitimacy. Originality/value: The study shows that leadership set-up is not the predominant factor that creates interdisciplinary cooperation; but rather, leader legitimacy also should be considered. Additionally, the study shows that leader legitimacy can be difficult to establish...... and that it cannot be taken for granted. This is something chief executive officers should bear in mind when they plan and implement new leadership structures. Therefore, it would also be useful to look more closely at how to achieve legitimacy in cases where the leader is from a different profession to the staff....

  9. A quantitative PGNAA study for use in aqueous solution measurements using Am–Be neutron source and BGO scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Ghal-Eh, N., E-mail: ghal-eh@du.ac.ir [School of Physics, Damghan University, P.O. Box 36716-41167, Damghan (Iran, Islamic Republic of); Ahmadi, P. [School of Physics, Damghan University, P.O. Box 36716-41167, Damghan (Iran, Islamic Republic of); Doost-Mohammadi, V. [Nuclear Science and Technology Research Center, AEOI, P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2016-02-01

    A prompt gamma neutron activation analysis (PGNAA) system including an Am–Be neutron source and BGO scintillation detector are used for quantitative analysis of bulk samples. Both Monte Carlo-simulated and experimental data are considered as input data libraries for two different procedures based on neural network and least squares methods. The results confirm the feasibility and precision of the proposed methods.

  10. Scratch to state-of-the-art: setting up a new robotic facility in a developing country.

    Science.gov (United States)

    Bora, G S; Mavuduru, R S; Devana, S K; Singh, S K; Mandal, A K

    2018-03-01

    The potential challenges encountered for setting up a robotic assisted surgical facility in developing country like India are many. We describe the initial hurdles and troubleshooting in establishing a facility of such kind. This experience might help to decrease initial hiccups in setting up such an innovative technology at other institutes.

  11. Development of new techniques and enhancement of automatic capability of neutron activation analysis at the Dalat Research Reactor

    International Nuclear Information System (INIS)

    Ho Manh Dung; Ho Van Doanh; Tran Quang Thien; Pham Ngoc Tuan; Pham Ngoc Son; Tran Quoc Duong; Nguyen Van Cuong; Nguyen Minh Tuan; Nguyen Giang; Nguyen Thi Sy

    2017-01-01

    The techniques of neutron activation analysis (NAA) including cyclic, epithermal and prompt-gamma (CNAA, ENAA and PGNAA, respectively) have been developed at the Dalat research reactor (DRR). In addition, the efforts has been spent to improve the automatic capability of irradiation, measurement and data processing of NAA. The renewal of necessary devices/tools for sample preparation have also been done. Eventually, the performance and the utility in terms of sensitivity, accuracy and stability of the analytical results generated by NAA at DRR have significantly been improved. The main results of the project are: 1) Upgrading of the fast irradiation system on Channel 13-2/TC to allow the cyclic irradiations; 2) Development of CNAA; 3) Development of ENAA; 4) Application of k0-method for PGNAA; 5) Investigation of the automatic sample changer (ASC2); 6) Upgrading of Ko-DALAT software for ENAA and modification of k0-IAEA software for CNAA and PGNAA; and 7) Optimization of irradiation and measurement facilities as well as sample preparation devices/tools. A set of procedures of relevant developed techniques in the project were established. The procedures have been evaluated by analysis of the reference materials for which they are meeting the requirements of multi-element analysis for the intended applications. (author)

  12. Developing and setting up of a nuclear medicine information management system

    International Nuclear Information System (INIS)

    Baghel, N.S.; Asopa, R.; Nayak, U.N.; Rajan, M.G.R.; Subhalakshmi, P.V.; Shailaja, A.; Rajashekharrao, B.; Karunanidhi, Y.R.

    2010-01-01

    Full text: With the advent and progress of information technology in the present decade, high-performance networks are being installed in hospitals to implement an effective and reliable Hospital Information Management Systems (HIMS). The Radiation Medicine Centre (RMC), is one of the earliest and largest nuclear medicine centres in India and several thousand patients undergo diagnostic as well as therapeutic procedures with different radiopharmaceuticals. The evolution towards a fully digital department of nuclear medicine is driven by expectations of not only improved patient management but also a well-defined workflow along with prompt and quality patient services. The aim was to develop and set up a practical and utility based Nuclear Medicine Information Management System (NMIMS) for various functional procedures at RMC. A customised NMIMS is developed with M/s ECIL using ASP.NET and SQL server technology facilitated by an IBM x3650 M3 Server, 18 thin-clients/desktop PCs and Windows 2008 server operating system and MS-SQL 2005 server software. The various modules have been developed to meet the requirements of different activities pertaining to patient appointment and scheduling, clinical assessment, radiopharmacy procedures, imaging and non-imaging studies and protocols, in-vitro laboratory tests, in-patient and out-patient treatment procedures, radiation protection and regulatory aspects and other routine operational procedures associated with patient management at RMC. The menus are developed as per scheduled workflow (SWF) in the department. The various aspects of SWF have been designed to ensure smooth, easy and trouble free patient management. Presently, the NMIMS has been developed excluding imaging data and we are in the process of setting up Picture Archiving Communication System (PACS) integrated to the existing database system, which will archive and facilitate imaging data in DICOM format in order to make a paperless department. The developed NMIMS

  13. Set-up for differential manometers testing

    International Nuclear Information System (INIS)

    Ratushnyj, M.I.; Galkin, Yu.V.; Nechaj, A.G.

    1985-01-01

    Set-up characteristic for controlling and testing metrological characteristics of TPP and NPP differential manometers with extreme pressure drop upto 250 kPa is briefly described. The set-up provides with automatic and manual assignment of values of gauge air pressure with errors of 0.1 and 0.25% correspondingly. The set-up is supplied with standard equipment to measure output signals. Set-up supply is carried out by a one-phase alternating current circuit with 220 V. Air supply is carried out by O.4-0.6 MPa. pressure of a pneumatic system. Application of the set-up increases operating efficiency 5 times while checking and turning differential manometers

  14. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    International Nuclear Information System (INIS)

    Rudat, Volker; Hammoud, Mohamed; Pillay, Yogin; Alaradi, Abdul Aziz; Mohamed, Adel; Altuwaijri, Saleh

    2011-01-01

    The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. In patients where high set-up accuracy is desired, daily online verification is highly recommended

  15. Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

    Directory of Open Access Journals (Sweden)

    Mohamed Adel

    2011-08-01

    Full Text Available Abstract Purpose The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM. Methods and materials Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT or three-dimensional conformal radiotherapy (3D-CRT of the head and neck (n = 31, chest (n = 72, abdomen (n = 15, and pelvis (n = 30 were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV. In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. Results The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. Conclusion In patients where high set-up accuracy is desired, daily online verification is highly recommended.

  16. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise's network function and enlarges its private scope. The text introduces virtual private network's principal, privileges and protocols that use in virtual private network. At last, this paper introduces several setting up virtual private network's technologies which based on LAN

  17. Setting up virtual private network

    International Nuclear Information System (INIS)

    Huang Hongmei; Zhang Chengjun

    2003-01-01

    Setting up virtual private network for business enterprise provides a low cost network foundation, increases enterprise network function and enlarges its private scope. This text introduces virtual private network principal, privileges and protocols applied in virtual private network. At last, this paper introduces several setting up virtual private network technologies which is based on LAN

  18. VITEX 2016 : Evaluation of learning objectives and exercise set-up

    NARCIS (Netherlands)

    Rijk, R. van; Stubbé-Alberts, H.E.

    2016-01-01

    To strengthen awareness of the need for cooperation, between public and private partners, and between countries, a new exercise set-up was developed. The VITEX exercise set-up is a table top exercise that aims to bring relevant networks together, and supports cooperation and collaboration between

  19. Special problems of setting up nuclear medicine in a developing country

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    There are some special problems in setting up nuclear medicine in a developing country. They can be briefly described in the form of the following general rules. 1) Impossible triangle. For the practice of nuclear medicine, three things are needed: Instrument, Radiopharmaceutical and a Patient. In a developing country, these three become three sides of an impossible triangle. When the radiopharmaceutical is available, the instrument may not be working; when the instrument is functioning, the radiopharmaceutical may not have been obtained from the foreign supplier; and when both are there, the patient might no longer be in the hospital. Three sides of this triangle never join to become a congruent whole. 2) Reverse square law. Further away one is from the source of supply of instruments and radiopharmaceuticals, the problems multiply by the square of this distance. 3) Future of nuclear medicine is tied to the electrical supply available in a developing country. These problems related to power supply are described in the Chapter on maintenance of instruments

  20. Special problems of setting up nuclear medicine in a developing country

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    There are some special problems in setting up nuclear medicine in a developing country. They can be briefly described in the form of the following general rules. 1) Impossible triangle. For the practice of nuclear medicine, three things are needed: Instrument, Radiopharmaceutical and a Patient. In a developing country, these three become three sides of an impossible triangle. When the radiopharmaceutical is available, the instrument may not be working; when the instrument is functioning, the radiopharmaceutical may not have been obtained from the foreign supplier; and when both are there, the patient might no longer be in the hospital. Three sides of this triangle never join to become a congruent whole. 2) Reverse square law. Further away one is from the source of supply of instruments and radiopharmaceuticals, the problems multiply by the square of this distance. 3) Future of nuclear medicine is tied to the electrical supply available in a developing country. These problems related to power supply are described in the Chapter on maintenance of instruments

  1. Development of high pressure rinsing set up for 650 MHz, 5- cell superconducting RF cavity cleaning

    International Nuclear Information System (INIS)

    Suhane, S.K.; Chauhan, S.K.; Bose, A.; Kokil, S.V.; Rajput, D.S.; Oraon, B.; Md Hussain; Sahu, A.; Raghavendra, S.; Joshi, S.C.

    2015-01-01

    High pressure rinsing (HPR) is an ultra-cleanliness process for the surface preparation of high field superconducting RF cavities. Any dust particle or chemical residue on the interior of cavity causes field emission. Jets of high pressure (80-100 bar) ultra pure water dislodge surface contaminants that normally resist removal with conventional rinsing procedures, leading to substantial reduction in field emission and better cavity performance. For cleaning of 650 MHz, 5-cell SRF cavities, a high pressure rinsing set up has been developed at RRCAT. The HPR tool has a rotating wand coaxial with the vertically mounted SRF cavity that is moving up and down. Fan style spray nozzles are attached to the end of the rotating wand and the water jets emerging from spray nozzles scan the entire internal surface of the cavity. The set-up was installed in a specially built clean area meeting cleanliness class 100 standards. The ultrapure water with resistivity 2 ≥ 18 MΩ-cm required for rinsing is obtained from a dedicated water purification system installed for this purpose. The paper describes the salient design and constructional details of the high pressure rinsing set up. Characterization of water jet parameters based on the momentum transfer between the water jet and a load cell is also presented. (author)

  2. Nuclear analytical chemistry: recent developments and applications

    International Nuclear Information System (INIS)

    Acharya, R.

    2013-01-01

    Recent R and D studies on Nuclear Analytical Chemistry utilizing techniques like Neutron Activation Analysis (NAA), Prompt Gamma-ray NAA (PGNAA), Particle Induced Gamma Ray and X-Ray Emission (PICE/PIXE) for compositional analysis of materials have been summarized. The work includes developments and applications of (i) single comparator NAA, called as k 0 -NAA, (ii) k 0 -based internal monostandard NAA (IM-NAA), (iii) k 0 -based prompt gamma ray NAA (PGNAA) and (iv) instrumental NAA using thermal and epithermal neutrons and (v) PIGE and PIXE methods using proton beam for low Z and medium Z elements, respectively. (author)

  3. Accuracy in tangential breast treatment set-up

    International Nuclear Information System (INIS)

    Tienhoven, G. van; Lanson, J.H.; Crabeels, D.; Heukelom, S.; Mijnheer, B.J.

    1991-01-01

    To test accuracy and reproducibility of tangential breast treatment set-up used in The Netherlands Cancer Institute, a portal imaging study was performed in 12 patients treated for early stage breast cancer. With an on-line electronic portal imaging device (EPID) images were obtained of each patient in several fractions and compared with simulator films and with each other. In 5 patients multiple images (on the average 7) per fraction were obtained to evaluate set-up variations due to respiratory movement. The central lung distance (CLD) and other set-up parameters varied within 1 fraction about 1mm (1SD). The average variation of these parameters between various fractions was about 2 mm (1SD). The differences between simulator and treatment set-up over all patients and all fractions was on the average 2-3mm for the central beam edge to skin distance and CLD. It can be concluded that the tangential breast treatment set-up is very stable and reproducible and that respiration does not have a significant influence on treatment volume. EPID appears to be an adequate tool for studies of treatment set-up accuracy like this. (author). 35 refs.; 2 figs.; 3 tabs

  4. SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

    International Nuclear Information System (INIS)

    Cho, M; Kim, T; Kang, S; Kim, D; Kim, K; Shin, D; Suh, T

    2015-01-01

    Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by

  5. SU-E-T-258: Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M; Kim, T; Kang, S; Kim, D; Kim, K; Shin, D; Suh, T [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attaching FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by

  6. Gamma-ray yield dependence on bulk density and moisture content of a sample of a PGNAA setup. A Monte Carlo study

    International Nuclear Information System (INIS)

    Nagadi, M.M.; Naqvi, A.A.

    2007-01-01

    Monte Carlo calculations were carried out to study the dependence of γ-ray yield on the bulk density and moisture content of a sample in a thermalneutron capture-based prompt gamma neutron activation analysis (PGNAA) setup. The results of the study showed a strong dependence of the γ-ray yield upon the sample bulk density. An order of magnitude increase in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in a Portland cement sample was observed for a corresponding order of magnitude increase in the sample bulk density. On the contrary the γ-ray yield has a weak dependence on sample moisture content and an increase of only 20% in yield of 1.94 and 6.42 MeV prompt γ-rays from calcium in the Portland cement sample was observed for an order of magnitude increase in the moisture content of the Portland cement sample. A similar effect of moisture content has been observed on the yield of 1.167 MeV prompt γ-rays from chlorine contaminants in Portland cement samples. For an order of magnitude increase in the moisture content of the sample, a 7 to 12% increase in the yield of the 1.167 MeV chlorine γ-ray was observed for the Portland cement samples containing 1 to 5 wt.% chlorine contaminants. This study has shown that effects of sample moisture content on prompt γ-ray yield from constituents of a Portland cement sample are insignificant in a thermal-neutrons capture-based PGNAA setup. (author)

  7. Interferences in Prompt {gamma} Analysis of corrosive contaminants in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2006-12-21

    An accelerator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup has been developed to measure the concentration of corrosive chloride and sulfate contaminants in concrete. The Minimum Detectable Concentration (MDC) limit of chlorine and sulfur in the concrete depends upon the {gamma}-ray used for elemental analysis. For more interfering {gamma}-rays, the MDC limit is higher than that for less interfering {gamma}-rays. The MDC limit of sulfur in concrete measured for the KFUPM PGNAA setup was calculated to be 0.60{+-}0.19 wt%. The MDC limit is equal to the upper limit of sulfur concentration in concrete set by the British Standards. The MDC limit of chlorine in concrete for the KFUPM PGNAA setup, which was calculated for less interfering 1.165 MeV {gamma}-rays, was found to be 0.075{+-}0.025 wt%. The lower limits of the MDC of chlorine in concrete was 73% higher than the limit set by American Concrete Institute. The limit of the MDC can be improved to the desired standard by increasing the intensity of neutron source. For moreinterfering 5.715 and 6.110 MeV chlorine {gamma}-rays the MDC limit was found to be 2-3 times larger than that of 1.165 MeV {gamma}-rays. When normalized to the same intensity of the neutron source, the MDC limits of chlorine and sulfur in concrete from the KFUPM PGNAA setup are better than MDC limits of chlorine in concrete obtained with the {sup 241}Am-Be source-based PGNAA setup. This study has shown that an accelerator-based PGNAA setup can be used in chlorine and sulfur analysis of concrete samples.

  8. Recent developments in comprehensive two-dimensional gas chromatography (GC X GC) I. Introduction and instrumental set-up

    NARCIS (Netherlands)

    Adahchour, M.; Beens, J.; Vreuls, R.J.J.; Brinkman, U.A.T.

    2006-01-01

    We review the literature on comprehensive two-dimensional gas chromatography (GC × GC), emphasizing developments in the period 2003-2005. The review opens with a general introduction, the principles of the technique and the set-up of GC × GC systems. It also discusses theoretical aspects, trends in

  9. Windows VPN Set Up | High-Performance Computing | NREL

    Science.gov (United States)

    Windows VPN Set Up Windows VPN Set Up To set up Windows for HPC VPN, here are the steps: Download your version of Windows. Note: We only support the the Endian Connect software when connecting to the a VPN connection to the HPC systems. Windows Version Connect App Windows 10

  10. Technologies for the Fast Set-Up of Automated Assembly Processes

    DEFF Research Database (Denmark)

    Krüger, Norbert; Ude, Ales; Petersen, Henrik Gordon

    2014-01-01

    of so called few-of-a-kind production. Therefore, most production of this kind is done manually and thus often performed in low-wage countries. In the IntellAct project, we have developed a set of methods which facilitate the set-up of a complex automatic assembly process, and here we present our work...

  11. Contribution to the development of the multidetector AMPHORA. Design of the electronic set up

    International Nuclear Information System (INIS)

    Stassi, P.

    1989-01-01

    The multidetector AMPHORA has been designed and built to be used to detect and identify all the particles produced in intermediate energy heavy ion reactions. This installation consist of 140 detectors built with CsI(TI) + NE102A and CsI(TI) + NE213 scintillators, covering nearly 81% of the solid angle around the target. These detectors can identify light charged particles, intermediate mass fragments and neutrons. The electronic set up associated is compact and requires little manual adjustment. It is built with special CAMAC modules which have the folowing functions: A 4 channel constant fraction discriminator and gate generator, a 16 channel charge to digital converter (12 bits), a 8 channel time to digital converter (12 bits), a 16 channel pile-up detector and a fast decision module. This thesis contains a detailed explanation of the principle and operation of the set up. It also contains a part which describes the way to connect all the modules of the electronic configuration for AMPHORA [fr

  12. Setting up of a cerebral visual impairment clinic for children: Challenges and future developments.

    Science.gov (United States)

    Philip, Swetha Sara

    2017-01-01

    The aim of this study is to describe the setting up of a cerebral visual impairment (CVI) clinic in a tertiary care hospital in South India and to describe the spectrum of cases seen. The CVI clinic, set up in February 2011, receives interdisciplinary input from a core team involving a pediatrician, neurologist, psychiatrist, occupational therapist, pediatric ophthalmologist, and an optometrist. All children, children (45%) had moderate CP. Forty percent of CVI was due to birth asphyxia, but about 20% did not have any known cause for CVI. Seventy percent of patients, who came back for follow-up, were carrying out the habilitation strategies suggested. Average attendance of over 300 new patients a year suggests a definite need for CVI clinics in the country. These children need specialized care to handle their complex needs. Although difficult to coordinate, an interdisciplinary team including the support groups and voluntary organizations is needed to facilitate the successful implementation of such specialized service.

  13. An experimental set-up to test heatmoisture exchangers

    NARCIS (Netherlands)

    N. Ünal (N.); J.C. Pompe (Jan); W.P. Holland (Wim); I. Gultuna; P.E.M. Huygen; K. Jabaaij (K.); C. Ince (Can); B. Saygin (B.); H.A. Bruining (Hajo)

    1995-01-01

    textabstractObjectives: The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. Design: The experimental set-up consists of a patient model, measurement

  14. Seminar on setting up your own business

    CERN Multimedia

    DSU Department

    2008-01-01

    Organised by the French-Swiss Foundation for Research and Technology (FFRST), in partnership with CERN, and open to all CERN personnel: Friday 7 March 2008, from 9.00 a.m. to 4.00 p.m. in the Globe of Science and Innovation Are you interested in setting up your own business? Have you already taken any steps in that direction? Do you wish to develop a business plan based on your own professional expertise? If so, you are cordially invited to take part in this seminar, at which you will have the opportunity to: hear first-hand accounts from former members of the CERN personnel who have become entrepreneurs and talk about their experience and needs in terms of financial support, find out about the possibilities for obtaining support at the national level (in Switzerland and France) through presentations of the CTI Start-up and OSEO programmes, have discussions with the relevant Swiss and French regional authorities responsible for supporting start-ups in innovative technolog...

  15. Seminar on setting up your own business

    CERN Multimedia

    DSU Department

    2008-01-01

    Organised by the French-Swiss Foundation for Research and Technology (FFRST), in partnership with CERN, and open to all CERN personnel: Friday 7 March 2008, from 9.00 a.m. to 4.00 p.m. in the Globe of Science and Innovation Are you interested in setting up your own business? Have you already taken any steps in that direction? Do you wish to develop a business plan based on your own professional expertise? If so, then you are cordially invited to take part in this seminar at which you will have the opportunity to: hear first-hand accounts from former members of the CERN personnel who have become entrepreneurs and talk about their experience and needs in terms of financial support, find out about the possibilities of obtaining support at national level (in Switzerland and France) through presentations of the CTI Start-up and OSEO programmes, have discussions with the relevant Swiss and French regional authorities responsible for supporting start-ups in innovative technologies...

  16. An experimental set-up for carbon isotopic analysis of atmospheric ...

    Indian Academy of Sciences (India)

    We present here, an experimental set-up developed for the first time in India for the ... The internal reproducibility (precision) for the δ13C ... interaction of CO2 and water, and reproduce iso- ..... enhanced emission of anthropogenic CO2, varia-.

  17. PENURUNAN WAKTU SET-UP UNTUK PENINGKATAN EFEKTIFITAS PADA PT. X

    Directory of Open Access Journals (Sweden)

    Hendri Hendri

    2015-06-01

    Full Text Available PT. X bergerak dalam industri manufuktur yang memproduksi komponen otomotif yang  salah satu prosesnya adalah pembuatan bearing. Saat ini, persaingan dalam dunia bisnis semakin ketat. Situasi ini membuat organisasi untuk memperbaiki diri dengan penurunan waktu set-up supaya dapat menghilangkan pemborosan sehingga peningkatan efektifitas dapat dicapai. Untuk melakukan penurunan waktu set-up dalam penelitian ini menggunakan metode Single Minute Exchange of Dies (SMED. SMED adalah salah satu metoda improvement dari Lean Manufacturing yang digunakan untuk mempercepat waktu yang dibutuhkan untuk melakukan setup pergantian dari memproduksi satu jenis produk ke model produk lainnya. Penelitian ini bertujuan untuk mengetahui waktu Set up, serta mengetahui cara memperbaiki dan menurunkan waktu set up. Setelah dilakukan penelitian diketahui total waktu set up atau change over serta dilakukan perbaikan pada tiga titik yakni memindakan enam aktivitas internal menjadi aktivitas eksernal yang aktivitasnya dipersingkat, mengganti cara kerja setting/pengencangan baut dari cara manual ke alat bantu pengencangan dengan bantuan tekanan udara (pneumatic, dan mengganti cara kerja setting/penyetelan manual menjadi penyetelan dengan mengunakan block gauge. Secara keseluruhan terjadi penurunan waktu set up yang signifikan. Dengan demikian terjadi peningkatan efektifitas dengan menghilangkan pemborosan waktu set up sehinga terjadi peningkatan jumlah produksi per jam.

  18. A HPMT based set-up to characterize scintillating crystals

    International Nuclear Information System (INIS)

    D'Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R.

    1999-01-01

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  19. A HPMT based set-up to characterize scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    D' Ambrosio, C.; Ercoli, C.; Jaaskelainen, S.; Lecoeur, G.; Leutz, H.; Loos, R.; Piedigrossi, D.; Puertolas, D.; Rosso, E.; Schomaker, R

    1999-09-21

    We have developed a fully automatic measurement set-up, capable of measuring light yields arising from scintillating crystals in a linear range of about four orders of magnitude. The photodetector is a hybrid photomultiplier tube specially developed to optimize linear range and photon detection. Crystal and photodetector are temperature controlled by a closed water circuit, as this is essential when measuring low light yield scintillating crystals with a marked temperature dependence of their light yield. Gamma sources can be placed either on top or on the side of the crystal. In this latter case, the source can be automatically moved by a computer-controlled step motor to provide a uniformity profile of the light yield along the crystal. Tagged and not-tagged operation modes are possible. The whole set-up is computer-controlled in an effort to provide fast and reliable measurements, to characterize many crystals per day. This is important for the quality control of the lead tungstate crystals that will be applied in the electromagnetic calorimeter of the CMS-detector at the LHC at CERN. (author)

  20. Galvanic cells: setting up the Daniell cell.

    OpenAIRE

    Milla González, Miguel

    2008-01-01

    With the reagents (0.05M copper nitrate solution, 0.05M zinc nitrate solution) and material (glassware, potentiometer, electric wire) availabe in the laboratory, the user must set up the Daniell cell. Different configurations can be possible if the half cells are filled with either electrolyte solution. The cell connections to the measuring device can also be changed. In all instances, an explanation of the set up cell is obtained as well as of the measured potential difference.

  1. Set-Up and Punchline as Figure and Ground

    DEFF Research Database (Denmark)

    Keisalo, Marianna Päivikki

    the two that cannot be resolved by appeal to either set-up or punchline, but traps thought between them in an ‘epistemological problem’ as comedian Louis CK put it. For comedians, set-ups and punchlines are basic tools, practical and concrete ways to create and organize material. They are also familiar...

  2. Development and applications of k0 based NAA and prompt gamma-ray NAA methods at BARC

    International Nuclear Information System (INIS)

    Acharya, R.; Nair, A.G.C.; Sudarshan, K.; Goswami, A.; Reddy, A.V.R.

    2008-01-01

    A summary of k 0 -based R and D work on neutron activation analysis (NAA), internal mono standard NAA (IM-NAA) and prompt gamma-ray NAA (PGNAA) is presented. The k 0 -based NAA was standardized by characterizing irradiation sites of research reactors, validated using reference materials and applied to samples of different origin. Recently IM-NAA method was developed, validated for small and large size samples and applied for the analysis of large size as well as non-standard geometry samples. Studies on PGNAA included characterization of neutron beam, determinations of detection efficiency and prompt k 0 -factors, and analytical applications. (author)

  3. Splendidly blended: a machine learning set up for CDU control

    Science.gov (United States)

    Utzny, Clemens

    2017-06-01

    As the concepts of machine learning and artificial intelligence continue to grow in importance in the context of internet related applications it is still in its infancy when it comes to process control within the semiconductor industry. Especially the branch of mask manufacturing presents a challenge to the concepts of machine learning since the business process intrinsically induces pronounced product variability on the background of small plate numbers. In this paper we present the architectural set up of a machine learning algorithm which successfully deals with the demands and pitfalls of mask manufacturing. A detailed motivation of this basic set up followed by an analysis of its statistical properties is given. The machine learning set up for mask manufacturing involves two learning steps: an initial step which identifies and classifies the basic global CD patterns of a process. These results form the basis for the extraction of an optimized training set via balanced sampling. A second learning step uses this training set to obtain the local as well as global CD relationships induced by the manufacturing process. Using two production motivated examples we show how this approach is flexible and powerful enough to deal with the exacting demands of mask manufacturing. In one example we show how dedicated covariates can be used in conjunction with increased spatial resolution of the CD map model in order to deal with pathological CD effects at the mask boundary. The other example shows how the model set up enables strategies for dealing tool specific CD signature differences. In this case the balanced sampling enables a process control scheme which allows usage of the full tool park within the specified tight tolerance budget. Overall, this paper shows that the current rapid developments off the machine learning algorithms can be successfully used within the context of semiconductor manufacturing.

  4. Controlling Mechatronic Set-up Using Real-time Linux and CTC ++

    NARCIS (Netherlands)

    Broenink, Johannes F.; Jovanovic, D.S.; Hilderink, G.H.; van Amerongen, J.; Jonker, B.; Regtien, P.; Stramigioli, S.

    2002-01-01

    The development of control software for mechatronic systems is presented by means of a case study: a 2 DOF mechanical rotational set-up usable as a camera-positioning device. The control software is generated using the code generation facility of 20-SIM, thus guaranteeing the generated code being

  5. View of the WA10 set-up

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The WA10 experiment by the Geneva-Lausanne Collaboration was set-up in the H5 beam (unseparated, up to 50 GeV/c) to study K+-p --> K0pi+-p and other reactions of similar topology, and the energy dependence of resonance production.

  6. Application of video imaging for improvement of patient set-up

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Frenay, Michel; Betgen, Anja; Bois, Josien A. de; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: For radiotherapy of prostate cancer, the patient is usually positioned in the left-right (LR) direction by aligning a single marker on the skin with the projection of a room laser. The aim of this study is to investigate the feasibility of a room-mounted video camera in combination with previously acquired CT data to improve patient set-up along the LR axis. Material and methods: The camera was mounted in the treatment room at the caudal side of the patient. For 22 patients with prostate cancer 127 video and portal images were acquired. The set-up error determined by video imaging was found by matching video images with rendered CT images using various techniques. This set-up error was retrospectively compared with the set-up error derived from portal images. It was investigated whether the number of corrections based on portal imaging would decrease if the information obtained from the video images had been used prior to irradiation. Movement of the skin with respect to bone was quantified using an analysis of variance method. Results: The measurement of the set-up error was most accurate for a technique where outlines and groins on the left and right side of the patient were delineated and aligned individually to the corresponding features extracted from the rendered CT image. The standard deviations (SD) of the systematic and random components of the set-up errors derived from the portal images in the LR direction were 1.5 and 2.1 mm, respectively. When the set-up of the patients was retrospectively adjusted based on the video images, the SD of the systematic and random errors decreased to 1.1 and 1.3 mm, respectively. From retrospective analysis, a reduction of the number of set-up corrections (from nine to six corrections) is expected when the set-up would have been adjusted using the video images. The SD of the magnitude of motion of the skin of the patient with respect to the bony anatomy was estimated to be 1.1 mm. Conclusion: Video

  7. Setting up crowd science projects.

    Science.gov (United States)

    Scheliga, Kaja; Friesike, Sascha; Puschmann, Cornelius; Fecher, Benedikt

    2016-11-29

    Crowd science is scientific research that is conducted with the participation of volunteers who are not professional scientists. Thanks to the Internet and online platforms, project initiators can draw on a potentially large number of volunteers. This crowd can be involved to support data-rich or labour-intensive projects that would otherwise be unfeasible. So far, research on crowd science has mainly focused on analysing individual crowd science projects. In our research, we focus on the perspective of project initiators and explore how crowd science projects are set up. Based on multiple case study research, we discuss the objectives of crowd science projects and the strategies of their initiators for accessing volunteers. We also categorise the tasks allocated to volunteers and reflect on the issue of quality assurance as well as feedback mechanisms. With this article, we contribute to a better understanding of how crowd science projects are set up and how volunteers can contribute to science. We suggest that our findings are of practical relevance for initiators of crowd science projects, for science communication as well as for informed science policy making. © The Author(s) 2016.

  8. An experimental set-up to test heat-moisture exchangers

    NARCIS (Netherlands)

    Unal, N.; Pompe, J. C.; Holland, W. P.; Gültuna, I.; Huygen, P. E.; Jabaaij, K.; Ince, C.; Saygin, B.; Bruining, H. A.

    1995-01-01

    The purpose of this study was to build an experimental set-up to assess continuously the humidification, heating and resistance properties of heat-moisture exchangers (HMEs) under clinical conditions. The experimental set-up consists of a patient model, measurement systems and a ventilator. Surgical

  9. Setting up and managing a remote maintenance operation for fusion

    International Nuclear Information System (INIS)

    Haist, Bernhard

    2008-01-01

    Trying to set up and manage a remote maintenance operation for a thermonuclear fusion reactor is a complex undertaking. There are many problems and challenges which need addressing. This paper tries to guide the reader through this process by composing a list of generic problems and by analysing possible solutions. The first challenge before setting up a remote maintenance operation for a fusion reactor is the systematic analysis of all the remote handling requirements. Based upon this the remote handling concept, including facility layout and equipment, can be defined. The following aspects have to be considered and incorporated into the remote handling concept: - Remote handling task development. - Remote handling task logistics and resource management. - Command, control and human-machine interface system. - Viewing and camera systems. - Virtual reality and Augmented Reality software. - Automatic path planning and collision avoidance. - Remote transfer of heavy loads. - Maintainability of RH equipment. - Reliability, redundant systems and safety. - Rationalisation and modularity in both hardware and software. - Recovery from failure modes. - Condition monitoring and fault detection/prediction. - Ability to deal with unforeseen problems. Oxford Technologies Ltd. has a proven track record in setting up and running the Remote Handling group at the JET Joint Undertaking in Culham, UK. Based on the unique experience gained at JET, Oxford Technologies Ltd. also developed the current design and remote handling concept of the ITER Hot Cell during a study in 2004. Examples of both the JET remote handling experience and the ITER Hot Cell design and layout are given throughout this paper

  10. Setting up and managing a remote maintenance operation for fusion

    International Nuclear Information System (INIS)

    Haist, B.

    2007-01-01

    Trying to set up and manage a remote maintenance operation for a thermonuclear fusion reactor is a complex undertaking. There are many problems and challenges which need addressing. This paper tries to guide the reader through this process by composing a list of generic problems and by analysing possible solutions. The first challenge before setting up a remote maintenance operation for a fusion reactor is the systematic analysis of all the remote handling requirements. Based upon this the remote handling concept, including facility layout and equipment, can be defined. The following aspects have to be considered and incorporated into the remote handling concept: - Remote handling task development - Remote handling task logistics and resource management - Command, control and human-machine interface system - Viewing and camera systems - Virtual Reality and Augmented Reality software - Automatic path planning and collision avoidance - Remote transfer of heavy loads - Maintainability of RH Equipment - Reliability, redundant systems and safety - Rationalisation and modularity in both hardware and software - Recovery from failure modes - Condition monitoring and fault detection/prediction - Ability to deal with unforeseen problems Oxford Technologies Ltd has a proven track record in setting up and running the Remote Handling group at the JET Joint Undertaking in Culham, UK. Based on the unique experience gained at JET, Oxford Technologies Ltd also developed the current design and remote handling concept of the ITER Hot Cell during a study in 2004. Examples of both the JET Remote Handling experience and the ITER Hot Cell design and layout are given throughout this paper. (orig.)

  11. Setting up and managing a remote maintenance operation for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Haist, Bernhard [Oxford Technologies Ltd., 7 Nuffield Way, Abingdon, Oxon OX14 1RJ (United Kingdom)], E-mail: Bernhard.Haist@oxfordtechnologies.co.uk

    2008-12-15

    Trying to set up and manage a remote maintenance operation for a thermonuclear fusion reactor is a complex undertaking. There are many problems and challenges which need addressing. This paper tries to guide the reader through this process by composing a list of generic problems and by analysing possible solutions. The first challenge before setting up a remote maintenance operation for a fusion reactor is the systematic analysis of all the remote handling requirements. Based upon this the remote handling concept, including facility layout and equipment, can be defined. The following aspects have to be considered and incorporated into the remote handling concept: - Remote handling task development. - Remote handling task logistics and resource management. - Command, control and human-machine interface system. - Viewing and camera systems. - Virtual reality and Augmented Reality software. - Automatic path planning and collision avoidance. - Remote transfer of heavy loads. - Maintainability of RH equipment. - Reliability, redundant systems and safety. - Rationalisation and modularity in both hardware and software. - Recovery from failure modes. - Condition monitoring and fault detection/prediction. - Ability to deal with unforeseen problems. Oxford Technologies Ltd. has a proven track record in setting up and running the Remote Handling group at the JET Joint Undertaking in Culham, UK. Based on the unique experience gained at JET, Oxford Technologies Ltd. also developed the current design and remote handling concept of the ITER Hot Cell during a study in 2004. Examples of both the JET remote handling experience and the ITER Hot Cell design and layout are given throughout this paper.

  12. Mathematical model of the electronuclear set-up on the beam of the JINR synchrotron

    International Nuclear Information System (INIS)

    Barashenkov, V.S.; Kumawat, H.; Lobanova, V.A.; Kumar, V.

    2003-01-01

    On the base of the Monte Carlo code CASCADE, developed at JINR, a mathematical model of the deep-subcritical set-up with uranium blanket used in experiments underway at JINR using a 0.6-4 GeV proton beam, is created. The neutron spectra, yields and energies of generated particles are calculated and compared for several modifications of the set-up. The influence of paraffin and graphite moderators on the characteristics of particles escaping lead target is studied. The modelled set-up can be considered as a first step to experiments with the designed at JINR U-Pu ADS SAD with heat power of several tens of kW

  13. Mathematical Model of the Electronuclear Set-Up on the Beam of the JINR Synchrotron

    CERN Document Server

    Barashenkov, V S; Kumawat, H; Lobanova, V A

    2004-01-01

    On the base of the Monte Carlo code CASCADE, developed at JINR, a mathematical model of the deep-subcritical set-up with uranium blanket used in experiments underway at JINR using a 0.6-4 GeV proton beam, is created. The neutron spectra, yields and energies of generated particles are calculated and compared for several modifications of the set-up. The influence of paraffin and graphite moderators on the characteristics of particles escaping lead target is studied. The modelled set-up can be considered as a first step to experiments with the designed at JINR U-Pu ADS SAD with heat power of several tens of kW.

  14. Evaluation of rotational set-up errors in patients with thoracic neoplasms

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Fan Min; Yang Huanjun; Ren Jun; Xu Zhiyong; Jiang Guoliang

    2010-01-01

    Objective: To assess the rotational set-up errors in patients with thoracic neoplasms. Methods: 224 kilovoltage cone-beam computed tomography (KVCBCT) scans from 20 thoracic tumor patients were evaluated retrospectively. All these patients were involved in the research of 'Evaluation of the residual set-up error for online kilovoltage cone-beam CT guided thoracic tumor radiation'. Rotational set-up errors, including pitch, roll and yaw, were calculated by 'aligning the KVCBCT with the planning CT, using the semi-automatic alignment method. Results: The average rotational set-up errors were -0.28 degree ±1.52 degree, 0.21 degree ± 0.91 degree and 0.27 degree ± 0.78 degree in the left-fight, superior-inferior and anterior-posterior axis, respectively. The maximal rotational errors of pitch, roll and yaw were 3.5 degree, 2.7 degree and 2.2 degree, respectively. After correction for translational set-up errors, no statistically significant changes in rotational error were observed. Conclusions: The rotational set-up errors in patients with thoracic neoplasms were all small in magnitude. Rotational errors may not change after the correction for translational set-up errors alone, which should be evaluated in a larger sample future. (authors)

  15. Set-up of a pre-test mock-up experiment in preparation for the HCPB Breeder Unit mock-up experimental campaign

    Energy Technology Data Exchange (ETDEWEB)

    Hernández, F., E-mail: francisco.hernandez@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Kolb, M. [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials (IAM-WPT) (Germany); Ilić, M.; Kunze, A. [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Németh, J. [KFKI Research Institute for Particle and Nuclear Physics (Hungary); Weth, A. von der [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany)

    2013-10-15

    Highlights: ► As preparation for the HCPB-TBM Breeder Unit out-of-pile testing campaign, a pre-test experiment (PREMUX) has been prepared and described. ► A new heater system based on a wire heater matrix has been developed for imitating the neutronic volumetric heating and it is compared with the conventional plate heaters. ► The test section is described and preliminary thermal results with the available models are presented and are to be benchmarked with PREMUX. ► The PREMUX integration in the air cooling loop L-STAR/LL in the Karlsruhe Institute for Technology is shown and future steps are discussed. -- Abstract: The complexity of the experimental set-up for testing a full-scaled Breeder Unit (BU) mock-up for the European Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) has motivated to build a pre-test mock-up experiment (PREMUX) consisting of a slice of the BU in the Li{sub 4}SiO{sub 4} region. This pre-test aims at verifying the feasibility of the methods to be used for the subsequent testing of the full-scaled BU mock-up. Key parameters needed for the modeling of the breeder material is also to be determined by the Hot Wire Method (HWM). The modeling tools for the thermo-mechanics of the pebble beds and for the mock-up structure are to be calibrated and validated as well. This paper presents the setting-up of PREMUX in the L-STAR/LL facility at the Karlsruhe Institute of Technology. A key requirement of the experiments is to mimic the neutronic volumetric heating. A new heater concept is discussed and compared to several conventional heater configurations with respect to the estimated temperature distribution in the pebble beds. The design and integration of the thermocouple system in the heater matrix and pebble beds is also described, as well as other key aspects of the mock-up (dimensions, layout, cooling system, purge gas line, boundary conditions and integration in the test facility). The adequacy of these methods for the full-scaled BU

  16. French scientists offered time to set up companies

    CERN Document Server

    Butler, D

    1999-01-01

    The French minister of national education, research and technology announced that French researchers working for public research institutes and universities are to be offered up to six years sabbatical leave to set up their own companies (11 para)

  17. Installing and Setting Up Git Software Tool on Windows | High-Performance

    Science.gov (United States)

    Computing | NREL Git Software Tool on Windows Installing and Setting Up Git Software Tool on Windows Learn how to set up the Git software tool on Windows for use with the Peregrine system. Git is this doc, we'll show you how to get git installed on Windows 7, and how to get things set up on NREL's

  18. A method for patient set-up guidance in radiotherapy using augmented reality

    International Nuclear Information System (INIS)

    Talbot, J.; Meyer, J.; Watts, R.; Grasset, R.

    2009-01-01

    Full text: A system for patient set-up in external beam radiotherapy was developed using Augmented Reality (AR). Live images of the linac treatment couch and patient were obtained with video cameras and displayed on a nearby monitor. A 3D model of the patient's external contour was obtained from planning CT data, and AR tracking software was used to superimpose the model onto the video images in the correct position for treatment. Throughout set-up and treatment, the user can view the monitor and visually confirm that the patient is positioned correctly. To ensure that the virtual contour was displayed in the correct position, a process was devised to register the coordinates of the linac with the camera images. A cube with AR tracking markers attached to its faces was constructed for alignment with the isocentre using room lasers or cone-beam CT. The performance of the system was investigated in a clinical environment by using it to position an anthropomorphic phantom without the aid of additional set-up methods. The positioning errors were determined by means of CBCT and image registration. The translational set-up errors were found to be less than 2.4 mm and the rotational errors less than 0.3 0 . This proof-of-principle study has demonstrated the feasibility of using AR for patient position and pose guidance.

  19. Improving beam set-up using an online beam optics tool

    International Nuclear Information System (INIS)

    Richter, S.; Barth, W.; Franczak, B.; Scheeler, U.; Wilms, D.

    2004-01-01

    The GSI accelerator facility [1] consists of the Universal Linear Accelerator (Unilac), the heavy ion synchrotron SIS, and the Experimental Storage Ring (ESR). Two Unilac injectors with three ion source terminals provide ion species from the lightest such as hydrogen up to uranium. The High Current Injector (HSI) for low charge state ion beams provides mostly high intense but short pulses, whereas the High Charge State Injector (HLI) supplies long pulses with a high duty factor of up to 27%. Before entering the Alvarez section of the Unilac the ion beam from the HSI is stripped in a supersonic gas jet. Up to three different ion species can be accelerated for up to five experiments in a time-sharing mode. Frequent changes of beam energy and intensity during a single beam time period may result in time consuming set-up and tuning especially of the beam transport lines. To shorten these changeover times an online optics tool (MIRKO EXPERT) had been developed. Based on online emittance measurements at well-defined locations the beam envelopes are calculated using the actual magnet settings. With this input improved calculated magnet settings can be directly sent to the magnet power supplies. The program reads profile grid measurements, such that an atomized beam alignment is established and that steering times are minimized. Experiences on this tool will be reported. At the Unilac a special focus is put on high current operation with short but intense beam pulses. Limitations like missing non-destructive beam diagnostics, insufficient longitudinal beam diagnostics, insufficient longitudinal beam matching, and influence of the hard edged model for magnetic fields will be discussed. Special attention will be put on the limits due to high current effects with bunched beams. (author)

  20. How to set up a psychodermatology clinic.

    Science.gov (United States)

    Aguilar-Duran, S; Ahmed, A; Taylor, R; Bewley, A

    2014-07-01

    Psychodermatology is a recognized subspecialty, but lack of awareness among dermatologists and limitation of resources make the management of these patients challenging. Clinicians are often unsure about the practicalities of setting up a psychodermatology service. There is confusion about which model is best suited to which service, and about the development of a psychodermatology multidisciplinary team. To identify the necessary steps in setting up a psychodermatology clinic. The study was based on the experience of a UK-based psychodermatology unit and the recently published standards by the UK Psychodermatology Working Party. The type of service provision will depend on the type of patients seen in the unit. The core team will be composed of a psychodermatologist and a psychologist. Access to a psychiatrist is essential if patients present with primary psychiatric conditions or primary cutaneous conditions with suicidal or other psychiatric risks. Adequate training of the healthcare staff is advised. The premises and time allocation should be adequate, and this translates into higher tariffs. Using business care tariffs for people with mental health conditions might be more appropriate, as the consultations are longer and involve more members of staff; however, the overall cost remains lower than if these patients were seen in a general dermatology service or in the community. Psychodermatology services are globally limited, and yet the demand for psychodermatology care is high. There is evidence that dedicated psychodermatology services are cost-effective. Healthcare professionals need to be aware of the steps necessary to establish and maintain psychodermatology services. © 2014 British Association of Dermatologists.

  1. A Full-size High Temperature Superconducting Coil Employed in a Wind Turbine Generator Set-up

    DEFF Research Database (Denmark)

    Song, Xiaowei (Andy); Mijatovic, Nenad; Kellers, Jürgen

    2016-01-01

    A full-size stationary experimental set-up, which is a pole pair segment of a 2 MW high temperature superconducting (HTS) wind turbine generator, has been built and tested under the HTS-GEN project in Denmark. The performance of the HTS coil is crucial to the set-up, and further to the development...... is tested in LN2 first, and then tested in the set-up so that the magnetic environment in a real generator is reflected. The experimental results are reported, followed by a finite element simulation and a discussion on the deviation of the results. The tested and estimated Ic in LN2 are 148 A and 143 A...

  2. Developing a virtual reality application for training Nuclear Power Plant operators: Setting up a database containing dose rates in the refuelling plant

    International Nuclear Information System (INIS)

    Rodenas, J.; Zarza, I.; Burgos, M. C.; Felipe, A.; Sanchez-Mayoral, M. L.

    2004-01-01

    Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed. (authors)

  3. Practical guidelines for setting up neurosurgery skills training cadaver laboratory in India.

    Science.gov (United States)

    Suri, Ashish; Roy, Tara Sankar; Lalwani, Sanjeev; Deo, Rama Chandra; Tripathi, Manjul; Dhingra, Renu; Bhardwaj, Daya Nand; Sharma, Bhawani Shankar

    2014-01-01

    Though the necessity of cadaver dissection is felt by the medical fraternity, and described as early as 600 BC, in India, there are no practical guidelines available in the world literature for setting up a basic cadaver dissection laboratory for neurosurgery skills training. Hands-on dissection practice on microscopic and endoscopic procedures is essential in technologically demanding modern neurosurgery training where ethical issues, cost constraints, medico-legal pitfalls, and resident duty time restrictions have resulted in lesser opportunities to learn. Collaboration of anatomy, forensic medicine, and neurosurgery is essential for development of a workflow of cadaver procurement, preservation, storage, dissection, and disposal along with setting up the guidelines for ethical and legal concerns.

  4. Setting-Up Of A Film Dosimetry System For High Energy Electron Beams And Development Of Computer Programs For Data Processing

    International Nuclear Information System (INIS)

    Schwob, N.; Schwob, W.; Loewenthal, E.

    1999-01-01

    Film dosimetry has the advantage over other dosimetry methods, of having a high spatial resolution and a fast two dimensional data acquisition. We have set up a system using a film digitizer with its associated software, dedicated to radiosurgery and we have developed data processing programs in Visual Basic for Excel. Data acquisition is not limited to water equivalent media: correction factors can be provided in the data processing procedure

  5. Radiotherapy for breast cancer: respiratory and set-up uncertainties

    International Nuclear Information System (INIS)

    Saliou, M.G.; Giraud, P.; Simon, L.; Fournier-Bidoz, N.; Fourquet, A.; Dendale, R.; Rosenwald, J.C.; Cosset, J.M.

    2005-01-01

    Adjuvant Radiotherapy has been shown to significantly reduce locoregional recurrence but this advantage is associated with increased cardiovascular and pulmonary morbidities. All uncertainties inherent to conformal radiation therapy must be identified in order to increase the precision of treatment; misestimation of these uncertainties increases the potential risk of geometrical misses with, as a consequence, under-dosage of the tumor and/or overdosage of healthy tissues. Geometric uncertainties due to respiratory movements or set-up errors are well known. Two strategies have been proposed to limit their effect: quantification of these uncertainties, which are then taken into account in the final calculation of safety margins and/or reduction of respiratory and set-up uncertainties by an efficient immobilization or gating systems. Measured on portal films with two tangential fields. CLD (central lung distance), defined as the distance between the deep field edge and the interior chest wall at the central axis, seems to be the best predictor of set-up uncertainties. Using CLD, estimated mean set-up errors from the literature are 3.8 and 3.2 mm for the systematic and random errors respectively. These depend partly on the type of immobilization device and could be reduced by the use of portal imaging systems. Furthermore, breast is mobile during respiration with motion amplitude as high as 0.8 to 10 mm in the anteroposterior direction. Respiratory gating techniques, currently on evaluation, have the potential to reduce effect of these movements. Each radiotherapy department should perform its own assessments and determine the geometric uncertainties with respect of the equipment used and its particular treatment practices. This paper is a review of the main geometric uncertainties in breast treatment, due to respiration and set-up, and solutions proposed to limit their impact. (author)

  6. Coincidence set-up with a high duty-cycle, high energy electron accelerator

    International Nuclear Information System (INIS)

    Leconte, P.

    1981-01-01

    Important studies are now undertaken to develop continuous wave electron accelerators with energy ranging from 1 to 4 Gev. So very important effort must be now put on the development of the experimental set-up matching the performances expected from the electron beam. Major steps in the understanding of the nuclear systems will come from more and more exclusive experiments where well defined mechanisms will be selected

  7. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    Energy Technology Data Exchange (ETDEWEB)

    Imura, K [Division of Quantum Radiation Science, Department of Health Science, Graduate School of Medical Science, Kyushu University, Fukuoka (Japan); Fujibuchi, T; Hirata, H [Department of Health Science, Graduate School of Medical Science, Kyushu University, Fukuoka (Japan); Kaneko, K [Innovation Center for Educational Resource, Kyushu University, Fukuoka (Japan); Hamada, E [Cancer Treatment Center, Tobata Kyoritsu Hospital, Kitakyushu (Japan)

    2016-06-15

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performance by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to

  8. SU-F-P-18: Development of the Technical Training System for Patient Set-Up Considering Rotational Correction in the Virtual Environment Using Three-Dimensional Computer Graphic Engine

    International Nuclear Information System (INIS)

    Imura, K; Fujibuchi, T; Hirata, H; Kaneko, K; Hamada, E

    2016-01-01

    Purpose: Patient set-up skills in radiotherapy treatment room have a great influence on treatment effect for image guided radiotherapy. In this study, we have developed the training system for improving practical set-up skills considering rotational correction in the virtual environment away from the pressure of actual treatment room by using three-dimensional computer graphic (3DCG) engine. Methods: The treatment room for external beam radiotherapy was reproduced in the virtual environment by using 3DCG engine (Unity). The viewpoints to perform patient set-up in the virtual treatment room were arranged in both sides of the virtual operable treatment couch to assume actual performance by two clinical staffs. The position errors to mechanical isocenter considering alignment between skin marker and laser on the virtual patient model were displayed by utilizing numerical values expressed in SI units and the directions of arrow marks. The rotational errors calculated with a point on the virtual body axis as the center of each rotation axis for the virtual environment were corrected by adjusting rotational position of the body phantom wound the belt with gyroscope preparing on table in a real space. These rotational errors were evaluated by describing vector outer product operations and trigonometric functions in the script for patient set-up technique. Results: The viewpoints in the virtual environment allowed individual user to visually recognize the position discrepancy to mechanical isocenter until eliminating the positional errors of several millimeters. The rotational errors between the two points calculated with the center point could be efficiently corrected to display the minimum technique mathematically by utilizing the script. Conclusion: By utilizing the script to correct the rotational errors as well as accurate positional recognition for patient set-up technique, the training system developed for improving patient set-up skills enabled individual user to

  9. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    International Nuclear Information System (INIS)

    Stapleton, S; Zavgorodni, S; Popescu, I A; Beckham, W A

    2005-01-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot

  10. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans

    Science.gov (United States)

    Stapleton, S.; Zavgorodni, S.; Popescu, I. A.; Beckham, W. A.

    2005-02-01

    The fluence-convolution method for incorporating random set-up errors (RSE) into the Monte Carlo treatment planning dose calculations was previously proposed by Beckham et al, and it was validated for open field radiotherapy treatments. This study confirms the applicability of the fluence-convolution method for dynamic intensity modulated radiotherapy (IMRT) dose calculations and evaluates the impact of set-up uncertainties on a clinical IMRT dose distribution. BEAMnrc and DOSXYZnrc codes were used for Monte Carlo calculations. A sliding window IMRT delivery was simulated using a dynamic multi-leaf collimator (DMLC) transport model developed by Keall et al. The dose distributions were benchmarked for dynamic IMRT fields using extended dose range (EDR) film, accumulating the dose from 16 subsequent fractions shifted randomly. Agreement of calculated and measured relative dose values was well within statistical uncertainty. A clinical seven field sliding window IMRT head and neck treatment was then simulated and the effects of random set-up errors (standard deviation of 2 mm) were evaluated. The dose-volume histograms calculated in the PTV with and without corrections for RSE showed only small differences indicating a reduction of the volume of high dose region due to set-up errors. As well, it showed that adequate coverage of the PTV was maintained when RSE was incorporated. Slice-by-slice comparison of the dose distributions revealed differences of up to 5.6%. The incorporation of set-up errors altered the position of the hot spot in the plan. This work demonstrated validity of implementation of the fluence-convolution method to dynamic IMRT Monte Carlo dose calculations. It also showed that accounting for the set-up errors could be essential for correct identification of the value and position of the hot spot.

  11. Automotive RF immunity test set-up analysis

    NARCIS (Netherlands)

    Coenen, M.J.; Pues, H.; Bousquet, T.; Gillon, R.; Gielen, G.; Baric, A.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  12. Anhui Tongling Invests 1 Billion Yuan to Set up “Copper Industry Fund”

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    <正>On September 12, the signing ceremony for "Anhui Copper Industry Fund" set up by Anhui Tongling Development & Investment Group Co., Ltd. and Shanghai V. Stone Investment Management Co., Ltd. was held in Tongling. The fund is 1 billion yuan.

  13. An evaluation system of the setting up of predictive maintenance programmes

    International Nuclear Information System (INIS)

    Carnero, MaCarmen

    2006-01-01

    Predictive Maintenance can provide an increase in safety, quality and availability in industrial plants. However, the setting up of a Predictive Maintenance Programme is a strategic decision that until now has lacked analysis of questions related to its setting up, management and control. In this paper, an evaluation system is proposed that carries out the decision making in relation to the feasibility of the setting up. The evaluation system uses a combination of tools belonging to operational research such as: Analytic Hierarchy Process, decision rules and Bayesian tools. This system is a help tool available to the managers of Predictive Maintenance Programmes which can both increase the number of Predictive Maintenance Programmes set up and avoid the failure of these programmes. The Evaluation System has been tested in a petrochemical plant and in a food industry

  14. Setting up a child eye care centre: the Mercy Eye Hospital, Abak ...

    African Journals Online (AJOL)

    Aim: To document and share our experience in setting up a Child Eye Care Centre within a rural mission eye hospital and document subsequent development of services. Method: The location of the project was Mercy Eye Hospital (MEH) Abak, Akwa Ibom State in the South South zone of Nigeria). Consent to commence ...

  15. Set-up for steam generator tube bundle washing after explosion expanding the tubes

    International Nuclear Information System (INIS)

    Osipov, S.I.; Kal'nin, A.Ya.; Mazanenko, M.F.

    1985-01-01

    Set-up for steam generator tube bundle washing after the explosion expanding of tubes is described. Washing is accomplished by distillate. Steam is added to distillate for heating, and compersed air for preventing hydraulic shock. The set-up is equiped by control equipment. Set-up performances are presented. Time for one steam generator washing constitutes 8-12 h. High economic efficiency is realized due to the set-up introduction

  16. Influence of Daily Set-Up Errors on Dose Distribution During Pelvis Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, M.; Ivkovic, A.; Faj, D.; Rajevac, V.; Sobat, H.; Jurkovic, S.

    2011-01-01

    An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice for the cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy process, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose. We investigated a part of this difference caused by daily patient set-up errors. Daily set-up errors for 35 patients were measured. These set-up errors were simulated on 5 patients, using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The differences in dose distributions between the planned and shifted ''geometry'' were investigated. Additionally, an influence of the error on treatment plan selection was checked by analyzing the change in dose volume histograms, planning target volume conformity index (CI P TV) and homogeneity index (HI). Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients those errors could influence the choice of treatment plan since CI P TV fell under 97 %. Surprisingly, HI was not as sensitive as CI P TV on set-up errors. The results showed the need for minimizing daily set-up errors by quality assurance programme. (author)

  17. Localization of Manufacturing Capabilities in Setting Up Nuclear Power Plants

    International Nuclear Information System (INIS)

    Chadda, Sushil Kumar

    2011-01-01

    group for supply of forgings for nuclear reactor, vessels, steam generators, turbine generators and other safety critical components including pumps, valves, pipes and tubes, and other integration work for the balance of plant are summarized. In close association with its sister concerns like Kalyani Carpenter special Steels, the challenges to manufacture critical pieces of metal with advanced materials and alloys are being addressed. The paper would briefly touch upon these efforts on advanced materials and alloys. The company has planned significant investments for setting up an integrated manufacturing facility to clear the global bottleneck in the supply of ultra-heavy forgings for not only for light water reactors but also for a variety of other applications like conventional island rotors, shafts, etc. Bharat Forge is also setting up a dedicated steel plant and a large foundry to address the requirements of cast pieces, casings and the like in nuclear and conventional islands. The overall effort of the Group is to develop in-house capabilities for meeting most component specific requirement of nuclear power plants. Civil structuring involves execution by prior qualification with proven skills for specialized civil works needed in the construction of nuclear plants. Another group company is also gearing up to enhance its capabilities to undertake construction projects and execute EPC contracts. This company is also in dialogue with a number of nuclear design and engineering outfits of the world to sew up formidable combination of design, engineering, construction and execution strengths. In the context of Indian Nuclear Power Program, the various initiatives taken for overall human resource development to meet the demands requiring skills in high end technology manufacturing and project management are included. Kalyani Group's trans-continental efforts to join hands with various educational and training institutions to create and replicate world-class talent pool

  18. Goal setting with mothers in child development services.

    Science.gov (United States)

    Forsingdal, S; St John, W; Miller, V; Harvey, A; Wearne, P

    2014-07-01

    The aim of this grounded theory study was to explore mothers' perspectives of the processes of collaborative goal setting in multidisciplinary child development services involving follow-up home therapy. Semi-structured interviews were conducted in South East Queensland, Australia with 14 mothers of children aged 3-6 years who were accessing multidisciplinary child development services. Interviews were focussed around the process of goal setting. A grounded theory of Maternal Roles in Goal Setting (The M-RIGS Model) was developed from analysis of data. Mothers assumed Dependent, Active Participator and Collaborator roles when engaging with the therapist in goal-setting processes. These roles were characterized by the mother's level of dependence on the therapist and insight into their child's needs and therapy processes. Goal Factors, Parent Factors and Therapist Factors influenced and added complexity to the goal-setting process. The M-RIGS Model highlights that mothers take on a range of roles in the goal-setting process. Although family-centred practice encourages negotiation and collaborative goal setting, parents may not always be ready to take on highly collaborative roles. Better understanding of parent roles, goal-setting processes and influencing factors will inform better engagement with families accessing multidisciplinary child development services. © 2013 John Wiley & Sons Ltd.

  19. X-ray fluorescence (XRF) set-up with a low power X-ray tube

    International Nuclear Information System (INIS)

    Gupta, Sheenu; Deep, Kanan; Jain, Lalita; Ansari, M.A.; Mittal, Vijay Kumar; Mittal, Raj

    2010-01-01

    The X-ray fluorescence set-up with a 100 W X-ray tube comprises a computer controlled system developed for remote operation and monitoring of tube and an adjustable stable 3D arrangement to procure variable excitation energies with low scattered background. The system was tested at different filament currents/anode voltages. The MDL of the set-up at 0.05-1.00 mA/4-12 kV is found ∼(1-100) ppm for K and L excitations and ∼(200-700) ppm for M excitations of elements and improves with filament current and anode voltage. Moreover, L measurements for Sm and Eu at five K X-ray energies of elements(Z=29-40) and analytical determination in some synthetic samples were undertaken.

  20. An experimental set-up to measure Light Yield of Scintillating Fibres

    CERN Document Server

    Alfieri, C; Joram, C; Kenzie, M W

    2015-01-01

    In the context of the LHCb SciFi Tracker project, an experimental set up was designed and built to provide reliable and reproducible measurements of the light yield of scintillating fibres. This document describes the principle and technical realisation of the set-up. A few examples illustrate the operation and data analysis. In the first implementation of the set-up a photomultiplier tube with bialkali photocathode was used for the reading of the light from the fibres under test. In order to measure also green emitting fibres, the photomultiplier was replaced in January 2016 by a SiPM with higher sensitivity and larger spectral coverage1.

  1. An optimised set-up for total reflection particle induced X-ray emission

    International Nuclear Information System (INIS)

    Kan, J.A. van; Vis, R.D.

    1997-01-01

    MeV proton beams at small angles of incidence (0-35 mrad) are used to analyse trace elements on flat surfaces such as Si wafers or quartz substrates. In these experiments, the particle induced X-ray emission (PIXE) signal is used in a new optimized set-up. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Use of these large detector solid angles, combined with the reduction of bremsstrahlung background, affords limits of detection (LOD) of the order of 10 10 at cm -2 using total reflection particle induced X-ray emission (TPIXE). The LODs from earlier TPIXE measurements in a non-optimized set-up are used to estimate LODs in the new TPIXE set-up. Si wafers with low surface concentrations of V, Ni, Cu and Ag are used as standards to calibrate the LODs found with this set-up. The metal concentrations are determined by total reflection X-ray fluorescence (TXRF). The TPIXE measurements are compared with TXRF measurements on the same wafers. (Author)

  2. upSET, the Drosophila homologue of SET3, Is Required for Viability and the Proper Balance of Active and Repressive Chromatin Marks

    Directory of Open Access Journals (Sweden)

    Kyle A. McElroy

    2017-02-01

    Full Text Available Chromatin plays a critical role in faithful implementation of gene expression programs. Different post-translational modifications (PTMs of histone proteins reflect the underlying state of gene activity, and many chromatin proteins write, erase, bind, or are repelled by, these histone marks. One such protein is UpSET, the Drosophila homolog of yeast Set3 and mammalian KMT2E (MLL5. Here, we show that UpSET is necessary for the proper balance between active and repressed states. Using CRISPR/Cas-9 editing, we generated S2 cells that are mutant for upSET. We found that loss of UpSET is tolerated in S2 cells, but that heterochromatin is misregulated, as evidenced by a strong decrease in H3K9me2 levels assessed by bulk histone PTM quantification. To test whether this finding was consistent in the whole organism, we deleted the upSET coding sequence using CRISPR/Cas-9, which we found to be lethal in both sexes in flies. We were able to rescue this lethality using a tagged upSET transgene, and found that UpSET protein localizes to transcriptional start sites (TSS of active genes throughout the genome. Misregulated heterochromatin is apparent by suppressed position effect variegation of the wm4 allele in heterozygous upSET-deleted flies. Using nascent-RNA sequencing in the upSET-mutant S2 lines, we show that this result applies to heterochromatin genes generally. Our findings support a critical role for UpSET in maintaining heterochromatin, perhaps by delimiting the active chromatin environment.

  3. Setting up Schizosaccharomyces pombe crosses/matings

    DEFF Research Database (Denmark)

    Ekwall, Karl; Thon, Genevieve

    2017-01-01

    Here we provide methods for setting up standard crosses with Schizosaccharomyces pombe strains. All strain genotypes and pedigrees should be recorded in a laboratory strain book. Matings between two haploid strains of interest are induced on solid medium poor in nitrogen. Usually, sporulation agar...

  4. CHALLENGES IN SETTING UP QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY FACILITIES IN NIGERIA.

    Science.gov (United States)

    Inyang, S O; Egbe, N O; Ekpo, E

    2015-01-01

    The Nigerian Nuclear Regulatory Authority (NNRA) was established to regulate and control the use of radioactive and radiation emitting sources in Nigeria. Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the authorization of diagnostic radiology facilities in the Country. Some quality control tests (output, exposure linearity and reproducibility) were measured on the x-ray machines in the facilities that took part in the study. Questionnaire was developed to evaluate the frequencies at which QC tests were conducted in the facilities and the challenges in setting up QC. Results show great variation in the values of the QC parameters measured. Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study. The responses on the frequencies at which QC tests should be conducted did not correspond to the recommended standards; indicating that personnel were not familiar with QC implementation and may require further training on QC.

  5. Neutron activation analysis: recent developments and applications

    International Nuclear Information System (INIS)

    Acharya, R.; Reddy, A.V.R.

    2012-01-01

    Neutron activation analysis (NAA) is a powerful isotope specific nuclear analytical technique for simultaneous determination of major to trace elemental concentrations in diverse matrices. NAA is associated with high analytical sensitivities and low detection limits (ppm to ppb) due to utilization of high neutron flux from research reactors and high efficiency high resolution gamma ray spectrometry. Elemental concentrations are determined either by conventional NAA using relative method or by single comparator method of NAA (k 0 -NAA). Since 1994, Radiochemistry Division is actively engaged in developments and applications of k 0 -based NAA and Prompt Gamma ray NAA (PGNAA) methods for compositional characterization of materials, in addition to conventional instrumental NAA (INAA) and chemical NAA (CNAA) methods for total as well as speciation studies. The article briefly summarizes developments of k 0 based method of NAA using an external single comparator (k 0 -NAA) and an internal monostandard (lM-NAA) and PGNAA and their applications to small as well as large size samples. The article also briefly highlights the application of INAA and chemical NAA (CNAA) for speciation studies of arsenic and iodine in environmental and food samples respectively and bioaccesibility of selenium in food samples and trace elements wheatgrass samples

  6. Setting UP a decontamination and dismantling (D and D) scenario - methodology and tools developed leopard

    International Nuclear Information System (INIS)

    Pradoura, F.

    2009-01-01

    At the AREVA NC La Hague site, the former nuclear spent fuel reprocessing plant UP2-400 was shutdown on December 30, 2003. Since then, the cleaning up and dismantling activities have been carried by the DV/PRO project, which is the program management organization settled by AREVA NC, for valorization projects. SGN, part of the AREVA NC Engineering Business Unit, operates as the main contractor of the DV/PRO project and provides project management services related to decommissioning and waste management. Hence, SGN is in charge of building D and D's scenarios for all the facilities of the UP2-400 plant, in compliance with safety, technical and financial requirements. Main outputs are logic diagrams, block flow diagrams, wastes and effluents throughputs. In order to meet with AREVA NC's requirements and expectations, SGN developed specific process and tools methods adapted to the scale and complexity of decommissioning a plant with several facilities, with different kind of processes (chemical, mechanical), some of which are in operation and other being dismantled. Considering the number of technical data and inputs to be managed, this methodology leads to complex outputs such as schedules, throughputs, work packages... The development, the maintenance and the modification of these outputs become more and more difficult with the complexity and the size of the plant considered. To cope with these issues, SGN CDE/DEM UP2-400 project team has developed a dedicated tool to assist and optimize in elaborating D and D scenarios. This tool is named LEOPARD (Logiciel d'Elaboration et d'Optimisation des Programmes d'Assainissement Radiologique et de Demantelement) (Software for the Development and Optimization of Radiological Clean up and Dismantling Programs). The availability of this tool allowed the rapid construction of a test case (demonstrator) that has convinced DV/PRO of its numerous advantages and of the future further development potentials. Presentations of LEOPARD

  7. Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases

    International Nuclear Information System (INIS)

    Herfarth, K.K.; Debus, J.; Lohr, F.; Bahner, M.L.; Fritz, P.; Hoess, A.; Schlegel, W. Ph.D.; Wannenmacher, M.F.

    2000-01-01

    Purpose: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. Methods and Materials: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment. Results: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm). Conclusions: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections

  8. Building up STEM education professional learning community in school setting: Case of Khon Kaen Wittayayon School

    Science.gov (United States)

    Thana, Aduldej; Siripun, Kulpatsorn; Yuenyong, Chokchai

    2018-01-01

    The STEM education is new issue of teaching and learning in school setting. Building up STEM education professional learning community may provide some suggestions for further collaborative work of STEM Education from grounded up. This paper aimed to clarify the building up STEM education learning community in Khon Kaen Wittayayon (KKW) School setting. Participants included Khon Kaen University researchers, Khon Kaen Wittayayon School administrators and teachers. Methodology regarded interpretative paradigm. The tools of interpretation included participant observation, interview and document analysis. Data was analyzed to categories of condition for building up STEM education professional learning community. The findings revealed that the actions of developing STEM learning activities and research showed some issues of KKW STEM community of inquiry and improvement. The paper will discuss what and how the community learns about sharing vision of STEM Education, supportive physical and social conditions of KKW, sharing activities of STEM, and good things from some key STEM teachers' ambition. The paper may has implication of supporting STEM education in Thailand school setting.

  9. Initial verification of an induction heating set-up for injection molding

    DEFF Research Database (Denmark)

    Menotti, Stefano; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2013-01-01

    Molding of thin and long parts by injection molding leads to special requirements for the mold in order to ensure proper filling and acceptable cycle time. This paper investigates the applicability of embedded induction heating for the improvement of the filling of thin long parts. The object...... selected for the investigation is a thin spiral. For the complete molding of the component, elevated mold temperatures are required. For this propose a new injection molding set-up was developed, which allows rapid heating of the cavity wall by an induction heating system. The temperature was measured...

  10. IAEA Sets Up Team to Drive Nuclear Safety Action Plan

    International Nuclear Information System (INIS)

    2011-01-01

    Full text: The International Atomic Energy Agency is setting up a Nuclear Safety Action Team to oversee prompt implementation of the IAEA Action Plan on Nuclear Safety and ensure proper coordination among all stakeholders. The 12-point Action Plan, drawn up in the wake of the Fukushima Daiichi accident, was approved by the Agency's Board of Governors on 13 September and endorsed by all 151 Member States at its General Conference last week. The team will work within the Agency's Department of Nuclear Safety and Security, headed by Deputy Director General Denis Flory, and will coordinate closely with the Director General's Office for Policy. ''The Action Plan requires immediate follow-up,'' Director General Yukiya Amano said. ''This compact, dedicated team will assist Deputy Director General Flory in implementing the measures agreed in the Action Plan.'' Gustavo Caruso, Head of the Regulatory Activities Section in the IAEA's Division of Installation Safety, has been designated as the team's Special Coordinator for the implementation of the Action Plan. The IAEA has already started implementing its responsibilities under the Action Plan, including development of an IAEA methodology for stress tests for nuclear power plants. The methodology will be ready in October. (IAEA)

  11. Calculation errors of Set-up in patients with tumor location of prostate. Exploratory study; Calculo de errores de Set-up en pacientes con localizacion tumoral de prostata. Estudio exploratorio

    Energy Technology Data Exchange (ETDEWEB)

    Donis Gil, S.; Robayna Duque, B. E.; Jimenez Sosa, A.; Hernandez Armas, O.; Gonzalez Martin, A. E.; Hernandez Armas, J.

    2013-07-01

    The calculation of SM is done from errors in positioning (set-up). These errors are calculated from movements in 3D of the patient. This paper is an exploratory study of 20 patients with tumor location of prostate in which errors of set-up for two protocols of work are evaluated. (Author)

  12. Over-relaxation phenomena during the set-up of RFP plasmas

    International Nuclear Information System (INIS)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab

  13. Over-relaxation phenomena during the set-up of RFP plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Nordlund, P.; Mazur, S.

    1995-03-01

    Experiments on the Extrap T1 reversed field pinch have shown that the formation of the RFP configuration is quite sensitive to the relative programming of the toroidal field and ohmic heating circuits. In this paper, new measurements of the evolution of the current density profile and of the spectral structure of the fluctuations during the set-up phase of RFP plasmas in the T1 experiment are presented. These measurements improve the understanding of the role of different spectral components in the dynamics of RFP formation. Under unfavourable (slow) set-up conditions, comparatively high energy is accumulated in m = 1 internal kinks prior to reversal of the edge toroidal fields. At reversal, nonlinearly driven m = 0 modes trigger a rapid broadening of the m = 1 spectrum. This behaviour is associated with a violent suppression of the current density in the core leading to an over-relaxation of the discharge involving a hollowing of the parallel current density profile. The over-relaxation phenomenon increases the volt-second consumption and plasma/wall interaction during RFP set-up, and degrades the flat-top discharge performance. 15 refs, 5 figs, 1 tab.

  14. Evaluation of spatial sensitivity of a prompt gamma neutron activation analysis facility for the in vivo determination of nitrogen in small animals

    International Nuclear Information System (INIS)

    Kasviki, K.; Ioannina University; Stamatelatos, I.E.; Kalef-Ezra, J.

    2007-01-01

    We investigated the spatial dependence of the sensitivity of nitrogen measurement with a prompt gamma neutron activation analysis (PGNAA) system for small animals and developed an analysis procedure that permits the reduction of systematic errors due to that dependence. The analysis procedure is based on neutron and photon transport calculations performed using the MCNP code in order to evaluate the sensitivity of the PGNAA facility. The system can be calibrated experimentally using a small number of phantoms of known size and composition. The calculation approach can then be used to predict responses for animal body sizes and shapes relatively to those experimentally determined and to include the effect of tissue inhomogeneities. Our calculations were verified by experimental measurements performed for a set of cylindrical inhomogeneous phantoms. The calculated to experimental ratios observed were within 6%. (author)

  15. LS1 Report: A brand new set-up for ASACUSA-CUSP

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    ASACUSA is running for the first time with a totally new set-up. Three new vital instruments have been designed, produced and installed during LS1 in addition to several other major modifications. The collaboration is now ready to perform the first high-precision measurement of the hyperfine structure of antihydrogen – a study that aims at comparing the inner properties of matter and antimatter.   The ASACUSA set-up. The ASACUSA-CUSP collaboration comprises about 30 scientists from various institutes in Europe and Japan. Because of the Japanese contribution, the experiment is often known by its Japanese pronunciation, the experiment’s logo is in Japanese, and the logbook uses Japanese time! This year, for the first time, the experiment is running with a completely new set-up, which now includes a new superconducting double cusp magnet, a new tracking detector and a new final antihydrogen detector. “The magnet is the heart of the ASACUSA experiment,” expl...

  16. Anaesthesia in Congenital Facial Anomalies in a Rural Set up of a Developing Country

    Directory of Open Access Journals (Sweden)

    Debasish Saha

    2015-01-01

    Full Text Available Background: India has an estimated backlog of 1000000 cleft patients. A total of 35000 new cleft patients are born each year. With the capacity to operate on approximately 50000 patients each year only 15000 patients from the national backlog can be operated upon each year if capability is not augmented. Objectives: To reach the population at large we meticulously planned an out-reach programme and operated on patients even in rural set ups with lack of modern facilities. We operated on patients at sub divisional centres, where apparatus for providing sevoflurane was not available. Institutional Ethical clearance was taken before conduction of the study. Patients who required prolonged surgery were taken to the tertiary centre. Working ventilators were also not available at peripheral centres. Materials and Methods: This interventional study was carried in a time span of four years on nineteen hundred and nine patients, after taking approval from the Institutional Ethical Committee. Patients were screened and some were operated at rural centers and others at a tertiary care centre. Patients who could not afford to come to the tertiary care centre were operated at different rural centers. Informed consent was taken. Results: There were 1909 patients with Congenital Facial Anomalies (CFA over four years period out of which 918 patients were of either unilateral or bilateral cleft lip. They were successfully operated at rural health centers with limited facilities. This could reduce the total load of surgeries for CFA at tertiary care hospital ensuring safe surgeries for all with CFA for all age groups and both genders.No mortality was recorded and post operative complications consisted of nausea and vomiting, three had delayed recovery and one had laryngospasm. Conclusion: Outreach programmes can increase the efficacy of Smile Train Project and effective screening of patients before surgery can result in fruitful outcomes even in a rural set up

  17. Analysis method set up to check against adulterated export honey

    International Nuclear Information System (INIS)

    Lyon, G.L.

    2001-01-01

    Over the past few years, North America has experienced occasional problems with the adulteration of honey, mainly by additions of other, cheaper sugar to increase bulk and lower production costs. The main addition was usually high fructose corn syrup, which had a similar chemical composition to that of honey. As a consequence of this type of adulteration, a method for its detection was developed using isotope ratio mass spectroscopy (IRMS). This was later refined to be more sensitive and is now specified as an Official Test. The Institute of Geological and Nuclear Sciences has now set up the analysis method to the international criteria at the Rafter Stable Isotope Laboratory in Lower Hutt. 2 refs

  18. Setting-up a cost recovery system for the largest wastewater treatment plant in South-East Asia.

    Science.gov (United States)

    Lønholdt, J; Elberg Jørgensen, P; O'Hearn, D

    2005-01-01

    A tariff system has been set up for the largest wastewater treatment plant in South-East Asia, the Samut Prakarn Wastewater Treatment Plant south of Bangkok, which is currently under completion. Fully functional the plant will have a design capacity for 500,000 m3 per day and will service a combined residential and industrial area with approximately 600,000 residents and 2,300 factories. The tariff system, which includes a tariff model, is based on water consumption and BOD load. As background for setting the tariffs a comprehensive monitoring system including an industrial permitting system has been developed. The paper presents the background and rationale for setting up the system as well as the objective, scope and content of the tariff system and the industrial permit system. Further, the feasibility of introducing cost recovery systems, which is widely accepted in developing economies on the conceptual level and to some extent implemented at the legal and regulatory level, but has yet to be implemented at large, is discussed.

  19. Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation

    International Nuclear Information System (INIS)

    Boer, Hans C.J. de; Soernsen de Koste, John R. van; Creutzberg, Carien L.; Visser, Andries G.; Levendag, Peter C.; Heijmen, Ben J.M.

    2001-01-01

    Purpose: To quantify systematic and random patient set-up errors in head and neck irradiation and to investigate the impact of an off-line correction protocol on the systematic errors. Material and methods: Electronic portal images were obtained for 31 patients treated for primary supra-glottic larynx carcinoma who were immobilised using a polyvinyl chloride cast. The observed patient set-up errors were input to the shrinking action level (SAL) off-line decision protocol and appropriate set-up corrections were applied. To assess the impact of the protocol, the positioning accuracy without application of set-up corrections was reconstructed. Results: The set-up errors obtained without set-up corrections (1 standard deviation (SD)=1.5-2 mm for random and systematic errors) were comparable to those reported in other studies on similar fixation devices. On an average, six fractions per patient were imaged and the set-up of half the patients was changed due to the decision protocol. Most changes were detected during weekly check measurements, not during the first days of treatment. The application of the SAL protocol reduced the width of the distribution of systematic errors to 1 mm (1 SD), as expected from simulations. A retrospective analysis showed that this accuracy should be attainable with only two measurements per patient using a different off-line correction protocol, which does not apply action levels. Conclusions: Off-line verification protocols can be particularly effective in head and neck patients due to the smallness of the random set-up errors. The excellent set-up reproducibility that can be achieved with such protocols enables accurate dose delivery in conformal treatments

  20. Essential Requirements to Setting up an Aesthetic Practice

    OpenAIRE

    Sachdev, Mukta; Britto, Gillian R

    2014-01-01

    Aesthetic dermatology is becoming a vital and popular branch of medicine. This article aims to guide dermatologists to set up a professional and ethical aesthetic practice. Dermatologists should have an integrated practice of clinical dermatology, dermatosurgery and cosmetic dermatology. Ethical practice is the gold standard for any medical field, especially with dermatologists, who should avoid doing unnecessary procedures. Proper patient counselling and addressing the patients′ concerns is ...

  1. INL Neutron Interrogation R and D: FY2010 MPACT End of Year Report

    International Nuclear Information System (INIS)

    Chichester, D.L.; Seabury, E.H.; Wharton, J.; Watson, S.M.

    2010-01-01

    Experiments have been carried out to investigate the feasibility and utility of using neutron interrogation and small-scale, portable prompt gamma-ray neutron activation analysis (PGNAA) instruments for assaying uranium for safeguards applications. Prior work has shown the potential of the PGNAA technique for assaying uranium using reactor-based neutron sources and high-yield electronic neutron generators (ENGs). In this project we adapted Idaho National Laboratory's portable isotopic neutron spectroscopy (PINS) PGNAA system for measuring natural-enrichment uranium yellowcake and metallic depleted uranium and highly enriched uranium. This work used 252Cf as well as deuterium-deuterium (DD) and deuterium-tritium (DT) ENGs. For PGNAA measurements a limiting factor when assaying large objects is the detector dead time due to fast-neutron scattering off of the uranium; this limits the maximum useable neutron source strength to O(107) neutrons per second. Under these conditions the low PGNAA reaction cross sections for uranium prohibited the collection of useful uranium PGNAA signatures from either the yellowcake or metallic uranium samples. Measurement of the decay product activation in these materials following irradiation in the PGNAA geometry similarly did not produce useful uranium activation product - fission product signatures. A customized irradiation geometry tailored to optimally thermalize the interrogation neutron source, intended only for generating long-lived activation products - fission products and not intended for PGNAA measurements, might be possible using small scale ENGs but an application need and a modeling simulation exercise would be recommended before advancing to experiments. Neutron interrogation PGNAA using a DT-ENG was found to be a quick and useful qualitative method for detecting the presence of oxygen in natural-enrichment uranium yellowcake. With a low effort of development work it would be reasonable to expect this measurement could be

  2. Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up.

    Science.gov (United States)

    Trozzi, C; Kaptein, B L; Garling, E H; Shelyakova, T; Russo, A; Bragonzoni, L; Martelli, S

    2008-10-01

    Model-based Roentgen Stereophotogrammetric Analysis (RSA) was recently developed for the measurement of prosthesis micromotion. Its main advantage is that markers do not need to be attached to the implants as traditional marker-based RSA requires. Model-based RSA has only been tested in uniplanar radiographic set-ups. A biplanar set-up would theoretically facilitate the pose estimation algorithm, since radiographic projections would show more different shape features of the implants than in uniplanar images. We tested the precision of model-based RSA and compared it with that of the traditional marker-based method in a biplanar set-up. Micromotions of both tibial and femoral components were measured with both the techniques from double examinations of patients participating in a clinical study. The results showed that in the biplanar set-up model-based RSA presents a homogeneous distribution of precision for all the translation directions, but an inhomogeneous error for rotations, especially internal-external rotation presented higher errors than rotations about the transverse and sagittal axes. Model-based RSA was less precise than the marker-based method, although the differences were not significant for the translations and rotations of the tibial component, with the exception of the internal-external rotations. For both prosthesis components the precisions of model-based RSA were below 0.2 mm for all the translations, and below 0.3 degrees for rotations about transverse and sagittal axes. These values are still acceptable for clinical studies aimed at evaluating total knee prosthesis micromotion. In a biplanar set-up model-based RSA is a valid alternative to traditional marker-based RSA where marking of the prosthesis is an enormous disadvantage.

  3. Feasibility of geometrical verification of patient set-up using body contours and computed tomography data

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Betgen, Anja; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: Body contours can potentially be used for patient set-up verification in external-beam radiotherapy and might enable more accurate set-up of patients prior to irradiation. The aim of this study is to test the feasibility of patient set-up verification using a body contour scanner. Material and methods: Body contour scans of 33 lung cancer and 21 head-and-neck cancer patients were acquired on a simulator. We assume that this dataset is representative for the patient set-up on an accelerator. Shortly before acquisition of the body contour scan, a pair of orthogonal simulator images was taken as a reference. Both the body contour scan and the simulator images were matched in 3D to the planning computed tomography scan. Movement of skin with respect to bone was quantified based on an analysis of variance method. Results: Set-up errors determined with body-contours agreed reasonably well with those determined with simulator images. For the lung cancer patients, the average set-up errors (mm)±1 standard deviation (SD) for the left-right, cranio-caudal and anterior-posterior directions were 1.2±2.9, -0.8±5.0 and -2.3±3.1 using body contours, compared to -0.8±3.2, -1.0±4.1 and -1.2±2.4 using simulator images. For the head-and-neck cancer patients, the set-up errors were 0.5±1.8, 0.5±2.7 and -2.2±1.8 using body contours compared to -0.4±1.2, 0.1±2.1, -0.1±1.8 using simulator images. The SD of the set-up errors obtained from analysis of the body contours were not significantly different from those obtained from analysis of the simulator images. Movement of the skin with respect to bone (1 SD) was estimated at 2.3 mm for lung cancer patients and 1.7 mm for head-and-neck cancer patients. Conclusion: Measurement of patient set-up using a body-contouring device is possible. The accuracy, however, is limited by the movement of the skin with respect to the bone. In situations where the error in the patient set-up is relatively large, it is

  4. Challenges in setting up quality control in diagnostic radiology ...

    African Journals Online (AJOL)

    Journal Home > Vol 24, No 4 (2015) >. Log in or ... Quality control (QC) on diagnostic radiology equipment form part of the fundamental requirements for the ... Inadequate cooperation by facilities management, lack of QC equipment and insufficient staff form the major challenges in setting up QC in the facilities under study.

  5. Setting up a control and certification system for organic farming in developing countries: the case of Algeria

    OpenAIRE

    ZIANE, Mrs Djamila

    2002-01-01

    The main objective of this work is to define the steps and the procedures to set up an effective control and certification system for Algeria, that is compatible with local peculiarities and realities and which complies with the International Regulations. The aim of this initiative is to offer a cost-efficient and credible inspection and certification for organic products to farmers, processors and traders. Doing so, the access to export and domestic markets should be facilitated. Furthermore...

  6. Market and Impact Study Setting Up MMX Discount Store

    OpenAIRE

    Sabina Irimie; Andreea Ionică; Virginia Băleanu; Cristina Osvath

    2008-01-01

    The paper is focused on the following elements of the impact study’s content: social and economic features of the area and the social, economic and commercial impact. Currently we witness the materialisation of the research’s results by setting up such a store MMX DISCOUNT in the town of Vulcan from the Jiu Valley

  7. Setting up your own business. Facing the future as an entrepreneur.

    Science.gov (United States)

    Brent, N J

    1990-01-01

    Other areas of setting up and running a business also are important to explore, especially if the business plans to use employees. You will become an employer, and you must be familiar with rules and regulations that include areas such as the employee's right to a safe workplace, worker's compensation laws, unemployment compensation laws and tax liabilities, antidiscrimination laws, and wage and tax laws. If independent contractors are going to be used, you must recognize that well-developed contracts are a necessity. If you are going to market a new product, consult with an attorney whose practice concentrates in trademark and patent law before the product is shared with others. Being well informed about the proposed business venture, not only before its establishment but as it develops and grows, can help you be in the best position to have a successful business.

  8. International Review of Frameworks for Standard Setting & Labeling Development

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Khanna, Nina Zheng [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    As appliance energy efficiency standards and labeling (S&L) programs reach a broader geographic and product scope, a series of sophisticated and complex technical and economic analyses have been adopted by different countries in the world to support and enhance these growing S&L programs. The initial supporting techno-economic and impact analyses for S&L development make up a defined framework and process for setting and developing appropriate appliance efficiency standards and labeling programs. This report reviews in-depth the existing framework for standards setting and label development in the well-established programs of the U.S., Australia and the EU to identify and evaluate major trends in how and why key analyses are undertaken and to understand major similarities and differences between each of the frameworks.

  9. Magnetic spectrometer of the DEUTERON-2 set-up

    International Nuclear Information System (INIS)

    Ajvazyan, R.V.; Alanakyan, K.V.; Amaryan, M.J.

    1989-01-01

    A magnetic spectrometer of the two-arm DEUTERON-2 set-up of the Erevan Physical Institute is described. It is shown that the rejection factor for electrons and pions is 10 -2 - 10 -3 . The positively charged particles in the momentum range up to 1.5 GeV/c are identified by momentum and time-of-flight measurements. The main characteristics of the spectrometer are: momentum and angular acceptance δp/p = 46%, Δθ = 4 deg, solid angle ΔΩ = 2.75 msr, momentum resolution δp/p = 1.5%, angular resolutions δθ = 0.6 deg, δφ = 2 deg. The intervals of measured momentum and the polar scattering anlge are 0.5-3 GeV/c and 10-30 deg, 68-90 deg respectively. 7 refs.; 11 figs

  10. Effectiveness of couch height-based patient set-up and an off-line correction protocol in prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Lin, Emile N.J.Th. van; Nijenhuis, Edwin; Huizenga, Henk; Vight, Lisette van der; Visser, Andries

    2001-01-01

    Purpose: To investigate set-up improvement caused by applying a couch height-based patient set-up method in combination with a technologist-driven off-line correction protocol in nonimmobilized radiotherapy of prostate patients. Methods and Materials: A three-dimensional shrinking action level correction protocol is applied in two consecutive patient cohorts with different set-up methods: the traditional 'laser set-up' group (n=43) and the 'couch height set-up' group (n=112). For all directions, left-right, ventro-dorsal, and cranio-caudal, random and systematic set-up deviations were measured. Results: The couch height set-up method improves the patient positioning compared to the laser set-up method. Without application of the correction protocol, both systematic and random errors reduced to 2.2-2.4 mm (1 SD) and 1.7-2.2 mm (1 SD), respectively. By using the correction protocol, systematic errors reduced further to 1.3-1.6 mm (1 SD). One-dimensional deviations were within 5 mm for >90% of the measured fractions. The required number of corrections per patient in the off-line correction protocol was reduced significantly during the course of treatment from 1.1 to 0.6 by the couch height set-up method. The treatment time was not prolonged by application of the correction protocol. Conclusions: The couch height set-up method improves the set-up significantly, especially in the ventro-dorsal direction. Combination of this set-up method with an off-line correction strategy, executed by technologists, reduces the number of set-up corrections required

  11. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    Directory of Open Access Journals (Sweden)

    Emanuel Heinz

    2013-12-01

    Full Text Available We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS for stable water isotope analysis (δ2H and δ18O, a reagentless hyperspectral UV photometer (ProPS for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system’s technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season.

  12. A Magnetic Set-Up to Help Teach Newton's Laws

    Science.gov (United States)

    Panijpan, Bhinyo; Sujarittham, Thanida; Arayathanitkul, Kwan; Tanamatayarat, Jintawat; Nopparatjamjomras, Suchai

    2009-01-01

    A set-up comprising a magnetic disc, a solenoid and a mechanical balance was used to teach first-year physics students Newton's third law with the help of a free body diagram. The image of a floating magnet immobilized by the solenoid's repulsive force should help dispel a common misconception of students as regards the first law: that stationary…

  13. CACTUS - a multidetector set-up at the Oslo Cyclotron

    International Nuclear Information System (INIS)

    Guttormsen, M.; Bjerke, B.; Messelt, S.; Olsen, E.A.; Ramsoey, T.; Rekstad, J.; Tveter, T.S.; Wikne, J.C.; Kownacki, J.

    1989-06-01

    The design and construction of the multidetector system CACTUS is discussed, and its operation in the context of the Oslo Cyclotron is described. The multidetector system has been initiated to meet the requirements at the Oslo Cyclotron Laboratory in the experimental work on nuclear structure at high intrinsic excitation energy. The laboratory has developed a promising technique based on measuring γ-decay after single nucleon transfer reactions with the use of pγ coincidences. However, a proper interpretation of the experimental results has often been difficult due to low counting rates. One of the most important aims for the new experimental set-up has been to obtain pγ as well as pγγ coincidence spectra with high statistics. The CACTUS detector system which is mounted on the 90 o beam line of the cyclotron, consists of 28 NaI and 2 Ge detectors in combination with 8 Si particle telescopes

  14. A managed clinical network for cardiac services: set-up, operation and impact on patient care.

    Science.gov (United States)

    Stc Hamilton, Karen E; Sullivan, Frank M; Donnan, Peter T; Taylor, Rex; Ikenwilo, Divine; Scott, Anthony; Baker, Chris; Wyke, Sally

    2005-01-01

    To investigate the set up and operation of a Managed Clinical Network for cardiac services and assess its impact on patient care. This single case study used process evaluation with observational before and after comparison of indicators of quality of care and costs. The study was conducted in Dumfries and Galloway, Scotland and used a three-level framework. Process evaluation of the network set-up and operation through a documentary review of minutes; guidelines and protocols; transcripts of fourteen semi-structured interviews with health service personnel including senior managers, general practitioners, nurses, cardiologists and members of the public. Outcome evaluation of the impact of the network through interrupted time series analysis of clinical data of 202 patients aged less than 76 years admitted to hospital with a confirmed myocardial infarction one-year pre and one-year post, the establishment of the network. The main outcome measures were differences between indicators of quality of care targeted by network protocols. Economic evaluation of the transaction costs of the set-up and operation of the network and the resource costs of the clinical care of the 202 myocardial infarction patients from the time of hospital admission to 6 months post discharge through interrupted time series analysis. The outcome measure was different in National Health Service resource use. Despite early difficulties, the network was successful in bringing together clinicians, patients and managers to redesign services, exhibiting most features of good network management. The role of the energetic lead clinician was crucial, but the network took time to develop and 'bed down'. Its primary "modus operand" was the development of a myocardial infarction pathway and associated protocols. Of sixteen clinical care indicators, two improved significantly following the launch of the network and nine showed improvements, which were not statistically significant. There was no difference

  15. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    International Nuclear Information System (INIS)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli; Zhou Sumin; Hollis, Donna R.; Wong, Terence Z.; Light, Kim L.; Hardenbergh, Patricia H.; Blazing, Michael A.; Marks, Lawrence B.

    2006-01-01

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI ≥25 kg/m 2 compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI ≥25 kg/m 2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT

  16. Stereo particle image velocimetry set up for measurements in the wake of scaled wind turbines

    Science.gov (United States)

    Campanardi, Gabriele; Grassi, Donato; Zanotti, Alex; Nanos, Emmanouil M.; Campagnolo, Filippo; Croce, Alessandro; Bottasso, Carlo L.

    2017-08-01

    Stereo particle image velocimetry measurements were carried out in the boundary layer test section of Politecnico di Milano large wind tunnel to survey the wake of a scaled wind turbine model designed and developed by Technische Universität München. The stereo PIV instrumentation was set up to survey the three velocity components on cross-flow planes at different longitudinal locations. The area of investigation covered the entire extent of the wind turbines wake that was scanned by the use of two separate traversing systems for both the laser and the cameras. Such instrumentation set up enabled to gain rapidly high quality results suitable to characterise the behaviour of the flow field in the wake of the scaled wind turbine. This would be very useful for the evaluation of the performance of wind farm control methodologies based on wake redirection and for the validation of CFD tools.

  17. Characterization of n-heptane as a single component Diesel surrogate fuel. EHPC test set-up implementation

    Energy Technology Data Exchange (ETDEWEB)

    Meijer, M.

    2010-06-15

    The availability of accurately measured fuel properties, during an injection event under engine relevant conditions is critical within the surrogate fuel approach. There is a need to perform in-house measurements in order to validate developed and new models. A well defined and accurately measured data-set will facilitate on-going work for sophisticated engine related in-cylinder combustion modeling. In this work pure n-heptane fuel is used as a single component surrogate fuel and is studied in a high-pressure constant volume optical test set-up. N-heptane is often used as a single component surrogate diesel fuel since it has a comparable Cetane number as European diesel. Detailed chemical-kinetic mechanisms for low-, intermediate-, and high-temperature n-heptane oxidation are available and several models exist that have sufficiently reduced dimensionality (number of species and reactions) to enable their use in CFD (Computational Fluid Mechanics) simulations. This report discusses the route and implementation to perform such an accurate and relevant n-heptane measurement series. The aim is to combine the efforts of earlier presented EHPC (Eindhoven High Pressure Cell) related work and new approaches, into the proposed surrogate fuel measurement series. The following aspects, related to the applied constant volume combustion chamber set-up, are studied and implemented: Extending the operating ranges towards relevant engine conditions; Study the accuracy and sensitivities of the different measurement steps; Implementing different optical diagnostic principles; and Implement a standardized and robust post processing routine. The different optical diagnostic principles used in this work are: high-speed Schlieren, Mie scattering and beginnings are made to implement a simultaneous LII LIF (Laser Induced Incandescence - Laser Induced Fluorescence) set-up using a new ICCD (Intensified Charge Coupled Device) camera with dual imaging feature. Combining the different

  18. Patient set-up verification by infrared optical localization and body surface sensing in breast radiation therapy

    International Nuclear Information System (INIS)

    Spadea, Maria Francesca; Baroni, Guido; Riboldi, Marco; Orecchia, Roberto; Pedotti, Antonio; Tagaste, Barbara; Garibaldi, Cristina

    2006-01-01

    Background and purpose: The aim of the study was to investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy, based on the 3D localization of a hybrid configuration of surface control points. Materials and methods: An infrared optical tracker provided the 3D position of two passive markers and 10 laser spots placed around and within the irradiation field on nine patients. A fast iterative constrained minimization procedure was applied to detect and compensate patient set-up errors, through the control points registration with reference data coming from treatment plan (markers reference position, CT-based surface model). Results: The application of the corrective spatial transformation estimated by the registration procedure led to significant improvement of patient set-up. Median value of 3D errors affecting three additional verification markers within the irradiation field decreased from 5.7 to 3.5 mm. Errors variability (25-75%) decreased from 3.2 to 2.1 mm. Laser spots registration on the reference surface model was documented to contribute substantially to set-up errors compensation. Conclusions: Patient set-up verification through a hybrid set of control points and constrained surface minimization algorithm was confirmed to be feasible in clinical practice and to provide valuable information for the improvement of the quality of patient set-up, with minimal requirement of operator-dependant procedures. The technique combines conveniently the advantages of passive markers based methods and surface registration techniques, by featuring immediate and robust estimation of the set-up accuracy from a redundant dataset

  19. Set-up for pulse radiolysis of agressive substances

    International Nuclear Information System (INIS)

    Kozlowska-Milner, E.; Broszkiewicz, R.; Stanikowski, J.

    1975-01-01

    A set-up for the pulse radiolysis of aggressive substances with a relatively low consumption of the liquid, tested for anhydrous HNO 3 , has been described. The samples have been irradiated with single pulses of 10 MeV electrons at the linear accelerator type LAE 13-9. The absorption spectra of the irradiated samples (within a range of 300-800 nm) were provided by a xenon lamp. The variations of the voltage from the photomultiplier, coupled with an oscilloscope, were registered with the aid of a Polaroid camera. (T.G.)

  20. Single ion hit detection set-up for the Zagreb ion microprobe

    Science.gov (United States)

    Smith, R. W.; Karlušić, M.; Jakšić, M.

    2012-04-01

    Irradiation of materials by heavy ions accelerated in MV tandem accelerators may lead to the production of latent ion tracks in many insulators and semiconductors. If irradiation is performed in a high resolution microprobe facility, ion tracks can be ordered by submicrometer positioning precision. However, full control of the ion track positioning can only be achieved by a reliable ion hit detection system that should provide a trigger signal irrespectively of the type and thickness of the material being irradiated. The most useful process that can be utilised for this purpose is emission of secondary electrons from the sample surface that follows the ion impact. The status report of the set-up presented here is based on the use of a channel electron multiplier (CEM) detector mounted on an interchangable sample holder that is inserted into the chamber in a close geometry along with the sample to be irradiated. The set-up has been tested at the Zagreb ion microprobe for different ions and energies, as well as different geometrical arrangements. For energies of heavy ions below 1 MeV/amu, results show that efficient (100%) control of ion impact can be achieved only for ions heavier than silicon. The successful use of the set-up is demonstrated by production of ordered single ion tracks in a polycarbonate film and by monitoring fluence during ion microbeam patterning of Foturan glass.

  1. Trace element analysis in an optimized set-up for total reflection PIXE (TPIXE)

    International Nuclear Information System (INIS)

    Van Kan, J.A.; Vis, R.D.

    1996-01-01

    A newly constructed chamber for measuring with MeV proton beams at small incidence angles (0 to 35 mrad) is used to analyse trace elements on flat surfaces such as Si wafers, quartz substrates and perspex. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Using these large solid angles in combination with the reduction of bremsstrahlungs background, lower limits of detection (LOD) using TPIXE can be obtained as compared with PIXE in the conventional geometry. Standard solutions are used to determine the LODs obtainable with TPIXE in the optimized set-up. These solutions contain traces of As and Sr with concentrations down to 20 ppb in an insulin solution. The limits of detection found are compared with earlier ones obtained with TPIXE in a non optimized set-up and with TXRF results. (author)

  2. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections.

    Science.gov (United States)

    Greer, P B; Dahl, K; Ebert, M A; Wratten, C; White, M; Denham, J W

    2008-10-01

    The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres and a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 11-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless implanted fiducial markers are available for treatment guidance.

  3. A user-friendly technical set-up for infrared photography of forensic findings.

    Science.gov (United States)

    Rost, Thomas; Kalberer, Nicole; Scheurer, Eva

    2017-09-01

    Infrared photography is interesting for a use in forensic science and forensic medicine since it reveals findings that normally are almost invisible to the human eye. Originally, infrared photography has been made possible by the placement of an infrared light transmission filter screwed in front of the camera objective lens. However, this set-up is associated with many drawbacks such as the loss of the autofocus function, the need of an external infrared source, and long exposure times which make the use of a tripod necessary. These limitations prevented up to now the routine application of infrared photography in forensics. In this study the use of a professional modification inside the digital camera body was evaluated regarding camera handling and image quality. This permanent modification consisted of the replacement of the in-built infrared blocking filter by an infrared transmission filter of 700nm and 830nm, respectively. The application of this camera set-up for the photo-documentation of forensically relevant post-mortem findings was investigated in examples of trace evidence such as gunshot residues on the skin, in external findings, e.g. hematomas, as well as in an exemplary internal finding, i.e., Wischnewski spots in a putrefied stomach. The application of scattered light created by indirect flashlight yielded a more uniform illumination of the object, and the use of the 700nm filter resulted in better pictures than the 830nm filter. Compared to pictures taken under visible light, infrared photographs generally yielded better contrast. This allowed for discerning more details and revealed findings which were not visible otherwise, such as imprints on a fabric and tattoos in mummified skin. The permanent modification of a digital camera by building in a 700nm infrared transmission filter resulted in a user-friendly and efficient set-up which qualified for the use in daily forensic routine. Main advantages were a clear picture in the viewfinder, an auto

  4. Realization of an automatic set up to measure electrical characteristic of solid state detectors

    International Nuclear Information System (INIS)

    Manfredotti, C.; Crosetto, D.; Gabutti, A.; Gervino, G.; Varesio, R.

    1986-01-01

    An automatic set-up is described to study electrical properties of silicon detectors for nuclear research. Particularly, I-V characteristics from silicon junction prototype detectors and amorphous samples to test the data acquisition system, are presented. This set-up joins a low cost to good versatility that makes it very useful in wide application ranges in silicon detector electrical characterization

  5. Research of vibration resistance of non-rigid shafts turning with various technological set-ups

    Directory of Open Access Journals (Sweden)

    Vasilevykh Sergey L.

    2017-01-01

    Full Text Available The article considers the definition of the stability range of a dynamic system for turning non-rigid shafts with different technological set-ups: standard and developed ones; they are improved as a result of this research. The topicality of the study is due to the fact that processing such parts is associated with significant difficulties caused by deformation of the workpiece under the cutting force as well as occurrence of vibration of the part during processing, they are so intense and in practice they force to significantly reduce the cutting regime, recur to multiple-pass operation, lead to premature deterioration of the cutter, as a result, reduce the productivity of machining shafts on metal-cutting machines. In this connection, the purpose of the present research is to determine the boundaries of the stability regions with intensive turning of non-rigid shafts. In the article the basic theoretical principles of construction of a mathematical system focused on the process of non-free cutting of a dynamic machine are justified. By means of the developed mathematical model interrelations are established and legitimacies of influence of various technological set-ups on stability of the dynamic system of the machine-tool-device-tool-blank are revealed. The conducted researches allow to more objectively represent difficult processes that occur in a closed dynamic system of a machine.

  6. Order of 27 February 1985 setting up a Nuclear Engineering Terminology Commission

    International Nuclear Information System (INIS)

    1985-01-01

    The Commission set up by this Order will draw up an inventory of the gaps in French nuclear engineering vocabulary, taking into account users' needs; it will also propose and revise the necessary terms in the light of present knowledge and contribute to collection and harmonisation of terminological and neological data. (NEA) [fr

  7. Special set-up and treatment techniques for the radiotherapy of pediatric malignancies

    International Nuclear Information System (INIS)

    Martinez, A.; Donaldson, S.S.; Bagshaw, M.A.

    1977-01-01

    The prevention of serious and long term complications of treatment have become as important a consideration in the therapy of children with malignant disease as the goal of tumor control. This balance requires meticulous treatment planning and attention to the treatment preparation and immobilization techniques when radiotherapy is administered to children. Accurate localization of tumor volume and daily reproducibility is essential for delivering precise irradiation. Four special set-up and treatment techniques which have a specific usefulness in radiotherapy for pediatric malignancies are defined and illustrated with the aid of clinical cases. They include the three point set-up, the split beam technique, the isocentric technique, and the strinking field technique

  8. Using a Robust Design Approach to Optimize Chair Set-up in Wheelchair Sport

    Directory of Open Access Journals (Sweden)

    David S. Haydon

    2018-02-01

    Full Text Available Optimisation of wheelchairs for court sports is currently a difficult and time-consuming process due to the broad range of impairments across athletes, difficulties in monitoring on-court performance, and the trade-off set-up that parameters have on key performance variables. A robust design approach to this problem can potentially reduce the amount of testing required, and therefore allow for individual on-court assessments. This study used orthogonal design with four set-up factors (seat height, depth, and angle, as well as tyre pressure at three levels (current, decreased, and increased for three elite wheelchair rugby players. Each player performed two maximal effort sprints from a stationary position in nine different set-ups, with this allowing for detailed analysis of each factor and level. Whilst statistical significance is difficult to obtain due to the small sample size, meaningful difference results aligning with previous research findings were identified and provide support for the use of this approach.

  9. Comparison of prostate set-up accuracy and margins with off-line bony anatomy corrections and online implanted fiducial-based corrections

    International Nuclear Information System (INIS)

    Greer, P. B.; Dahl, K.; Ebert, M. A.; Wratten, C.; White, M.; Denham, K. W.

    2008-01-01

    Full text: The aim of the study was to determine prostate set-up accuracy and set-up margins with off-line bony anatomy-based imaging protocols, compared with online implanted fiducial marker-based imaging with daily corrections. Eleven patients were treated with implanted prostate fiducial markers and online set-up corrections. Pretreatment orthogonal electronic portal images were acquired to determine couch shifts and verification images were acquired during treatment to measure residual set-up error. The prostate set-up errors that would result from skin marker set-up, off-line bony anatomy-based protocols and online fiducial marker-based corrections were determined. Set-up margins were calculated for each set-up technique using the percentage of encompassed isocentres land a margin recipe. The prostate systematic set-up errors in the medial-lateral, superior-inferior and anterior-I posterior directions for skin marker set-up were 2.2, 3.6 and 4.5 mm (1 standard deviation). For our bony anatomy-I based off-line protocol the prostate systematic set-up errors were 1.6, 2.5 and 4.4 mm. For the online fiducial based set-up the results were 0.5, 1.4 and 1.4 mm. A prostate systematic error of 10.2 mm was uncorrected by the off-line bone protocol in one patient. Set-up margins calculated to encompass 98% of prostate set-up shifts were 111-14 mm with bone off-line set-up and 4-7 mm with online fiducial markers. Margins from the van Herk margin I recipe were generally 1-2 mm smaller. Bony anatomy-based set-up protocols improve the group prostate set-up error compared with skin marks; however, large prostate systematic errors can remain undetected or systematic (errors increased for individual patients. The margin required for set-up errors was found to be 10-15 mm unless I implanted fiducial markers are available for treatment guidance.

  10. Synthesis and characterisation of polymeric nanofibers poly (vinyl alcohol) and poly (vinyl alcohol)/silica using indigenous electrospinning set up

    International Nuclear Information System (INIS)

    Sasipriya, K.; Suriyaprabha, R.; Prabu, P.; Rajendran, V.

    2013-01-01

    Indigenous design and fabrication horizontal of electrospinning set up was developed to facilitate with double drum conveyor belt system to make ease in harvesting nanofibers rapidly. As a bench mark study, organic-inorganic nanofiber composite was synthesised employing our indigenous electrospinning set up. The aqueous solution of poly (vinyl alcohol) and poly (vinyl alcohol)/silica sol were employed to produce nanofiber mats in order to vary the experimental parameters such as voltage, solvent effect and the effect of catalyst. The synthesised pure electro spun poly (vinyl alcohol) and poly (vinyl alcohol)/silica sol fibers were characterized by Scanning electron microscopy (SEM), Atomic force microscopy (AFM) and Fourier transform infra red spectroscopy (FTIR). According to the results, the fine polymeric nanofibers were achieved in the size range of 100-500 nm for pure poly (vinyl alcohol) fiber and 100-700 nm for polyvinyl alcohol/silica and the constitution of silica in rendering better fiber mats with this double drum set up. (author)

  11. Synthesis and characterisation of polymeric nanofibers poly (vinyl alcohol) and poly (vinyl alcohol)/silica using indigenous electrospinning set up

    Energy Technology Data Exchange (ETDEWEB)

    Sasipriya, K.; Suriyaprabha, R.; Prabu, P.; Rajendran, V., E-mail: veerajendran@gmail.com [Centre for Nanoscience and Technology, K. S. Rangasamy College of Technology, Tamil Nadu (India)

    2013-11-01

    Indigenous design and fabrication horizontal of electrospinning set up was developed to facilitate with double drum conveyor belt system to make ease in harvesting nanofibers rapidly. As a bench mark study, organic-inorganic nanofiber composite was synthesised employing our indigenous electrospinning set up. The aqueous solution of poly (vinyl alcohol) and poly (vinyl alcohol)/silica sol were employed to produce nanofiber mats in order to vary the experimental parameters such as voltage, solvent effect and the effect of catalyst. The synthesised pure electro spun poly (vinyl alcohol) and poly (vinyl alcohol)/silica sol fibers were characterized by Scanning electron microscopy (SEM), Atomic force microscopy (AFM) and Fourier transform infra red spectroscopy (FTIR). According to the results, the fine polymeric nanofibers were achieved in the size range of 100-500 nm for pure poly (vinyl alcohol) fiber and 100-700 nm for polyvinyl alcohol/silica and the constitution of silica in rendering better fiber mats with this double drum set up. (author)

  12. Synthesis and characterisation of polymeric nanofibers poly (vinyl alcohol and poly (vinyl alcohol/silica using indigenous electrospinning set up

    Directory of Open Access Journals (Sweden)

    K. Sasipriya

    2013-01-01

    Full Text Available Indigenous design and fabrication horizontal of electrospinning set up was developed to facilitate with double drum conveyor belt system to make ease in harvesting nanofibers rapidly. As a bench mark study, organic-inorganic nanofiber composite was synthesised employing our indigenous electrospinning set up. The aqueous solution of poly (vinyl alcohol and poly (vinyl alcohol/silica sol were employed to produce nanofiber mats in order to vary the experimental parameters such as voltage, solvent effect and the effect of catalyst. The synthesised pure electro spun poly (vinyl alcohol and poly (vinyl alcohol/silica sol fibers were characterized by Scanning electron microscopy (SEM, Atomic force microscopy (AFM and Fourier transform infra red spectroscopy (FTIR. According to the results, the fine polymeric nanofibers were achieved in the size range of 100-500 nm for pure poly (vinyl alcohol fiber and 100-700 nm for polyvinyl alcohol/silica and the constitution of silica in rendering better fiber mats with this double drum set up.

  13. SET protein up-regulated testosterone production in the cultured preantral follicles

    Directory of Open Access Journals (Sweden)

    Xu Boqun

    2013-02-01

    Full Text Available Abstract Background We found previously that the expression of SET gene was up-regulated in polycystic ovaries. Evidences suggested that SET protein was essential for regulating both the promoter activity of CYP17A1 and the biological activity of P450c17. In this study, we explored whether SET regulated androgen production in preantral follicles. Methods The mouse preantral follicles were cultured in vitro. Testosterone secretion and expression of steroidogenic enzymes were observed in the preantral follicles treated in vitro by SET overexpression and knockdown. Results Testosterone levels in the media of the AdCMV-SET infected follicles significantly increased, and the CYP17A1 and HSD3B2 expression also significantly increased (P P  Conclusions SET played a positive role in regulating ovarian androgen biosynthesis by enhancing the transcription of steroidogenic enzymes CYP17A1 and HSD3B2, which maybe contribute to the hyperandrogenism in PCOS.

  14. The set-up for forward scattered particle detection at the external microbeam facility of the INFN-LABEC laboratory in Florence

    International Nuclear Information System (INIS)

    Giuntini, L.; Massi, M.; Calusi, S.; Gelli, N.; Castelli, L.; Carraresi, L.; Czelusniak, C.; Fedi, M.E.; Gueli, A.M.; Liccioli, L.; Mandò, P.A.; Mazzinghi, A.; Palla, L.

    2015-01-01

    In the last few years some new implementations and upgrades have been made to the external scanning microbeam of INFN-LABEC laboratory in Florence, enriching the existing PIXE, PIGE, BS, IBIL set-up with complementary techniques, when possible allowing for simultaneous multi-technique analyses. We developed a system, compatible with the existing set-up, for the out-of-vacuum detection of the forward scattered particles. This system makes feasible the external-STIM (Scanning Transmission Ion Microscopy) and external-FS (Forward Scattering), now both available at our beamline. Test measurements are shortly presented

  15. Comparing signal intensity and refraction sensitivity of double and single mask edge illumination lab-based x-ray phase contrast imaging set-ups

    International Nuclear Information System (INIS)

    Kallon, G K; Diemoz, P C; Vittoria, F A; Basta, D; Endrizzi, M; Olivo, A

    2017-01-01

    Double mask edge illumination (DM-EI) set-ups can detect differential phase and attenuation information from a sample. However, analytical separation of the two signals often requires acquiring two frames with inverted differential phase contrast signals. Typically, between these two acquisitions, the first mask is moved to create a different illumination condition. This can lead to potential errors which adversely affect the data collected. In this paper, we implement a single mask EI laboratory set-up that allows for a single shot retrieval of the differential phase and attenuation images, without the need for a high resolution detector or high magnification. As well as simplifying mask alignment, the advantages of the proposed set-up can be exploited in one of two ways: either the total acquisition time can be halved with respect to the DM-EI set-up or, for the same acquisition time, twice the statistics can be collected. In this latter configuration, the signal-to-noise ratio and contrast in the mixed intensity images, and the angular sensitivity of the two set-ups were compared. We also show that the angular sensitivity of the single mask set-up can be well approximated from its illumination curve, which has been modelled as a convolution between the source spatial distribution at the detector plane, the pre-sample mask and the detector point spread function (PSF). A polychromatic wave optics simulation was developed on these bases and benchmarked against experimental data. It can also be used to predict the angular sensitivity and contrast of any set-up as a function of detector PSF. (paper)

  16. Cone beam CT-based set-up strategies with and without rotational correction for stereotactic body radiation therapy in the liver.

    Science.gov (United States)

    Bertholet, Jenny; Worm, Esben; Høyer, Morten; Poulsen, Per

    2017-06-01

    Accurate patient positioning is crucial in stereotactic body radiation therapy (SBRT) due to a high dose regimen. Cone-beam computed tomography (CBCT) is often used for patient positioning based on radio-opaque markers. We compared six CBCT-based set-up strategies with or without rotational correction. Twenty-nine patients with three implanted markers received 3-6 fraction liver SBRT. The markers were delineated on the mid-ventilation phase of a 4D-planning-CT. One pretreatment CBCT was acquired per fraction. Set-up strategy 1 used only translational correction based on manual marker match between the CBCT and planning CT. Set-up strategy 2 used automatic 6 degrees-of-freedom registration of the vertebrae closest to the target. The 3D marker trajectories were also extracted from the projections and the mean position of each marker was calculated and used for set-up strategies 3-6. Translational correction only was used for strategy 3. Translational and rotational corrections were used for strategies 4-6 with the rotation being either vertebrae based (strategy 4), or marker based and constrained to ±3° (strategy 5) or unconstrained (strategy 6). The resulting set-up error was calculated as the 3D root-mean-square set-up error of the three markers. The set-up error of the spinal cord was calculated for all strategies. The bony anatomy set-up (2) had the largest set-up error (5.8 mm). The marker-based set-up with unconstrained rotations (6) had the smallest set-up error (0.8 mm) but the largest spinal cord set-up error (12.1 mm). The marker-based set-up with translational correction only (3) or with bony anatomy rotational correction (4) had equivalent set-up error (1.3 mm) but rotational correction reduced the spinal cord set-up error from 4.1 mm to 3.5 mm. Marker-based set-up was substantially better than bony-anatomy set-up. Rotational correction may improve the set-up, but further investigations are required to determine the optimal correction

  17. Set-up of light nuclei multidetector

    International Nuclear Information System (INIS)

    Drouet, A.

    1985-01-01

    In order to study mechanisms of reactions produced by heavy ions in the GANIL energy range (15-100 MeV/A), a multidetector capable to detect large multiplicities for particles and light nuclei is necessary. The multidetector set up covers the 3-30 0 angular range and consists of 96 counters (NE102 plastic scintillator sheet, 2mm thick). The apparatus must identify the nuclear charge of the detected particles. Using the apparatus at GANIL leaded to carry out data processing tools in conversationnal mode and to write on experimental area programs performing and monitoring data acquisition. A test carried out with a 44 MeV/A argon beam showed that the apparatus was working properly: the identification in nuclear charge between Z=1 (proton) and Z=7 (nitrogen) is good. Results of the test allow to draw light production curves in the NE102 plastic scintillator for the following ions: 1 H, 4 He, 7 Li, 9 Be, 11 B, 12 C, 14 N, in the 13 to 44 MeV/A energy range [fr

  18. The possibility to use 'energy plus transmutation' set-up for neutron ...

    Indian Academy of Sciences (India)

    Neutron field was measured in different places of this set- up using different .... to see that the proton integral was around 1013 protons for all experiments. The shape of the .... The lines are drawn to guide the eyes, only statistical errors are ...

  19. Duty to speak up in the health care setting a professionalism and ethics analysis.

    Science.gov (United States)

    Topazian, Rachel J; Hook, C Christopher; Mueller, Paul S

    2013-11-01

    Staff and students working in health care settings are sometimes reluctant to speak up when they perceive patients to be at risk for harm. In this article, we describe four incidents that occurred at our institution (Mayo Clinic). In two of them, health care professionals failed to speak up, which resulted in harm; in the other two, they did speak up, which prevented harm and improved patient care. We analyzed each scenario using the Physician's Charter on Medical Professionalism and prima facie ethics principles to determine whether principles were violated or upheld. We conclude that anyone who works in a health care setting has a duty to speak up when a patient faces harm. We also provide guidance for health care institutions on promoting a culture in which speaking up is encouraged and integrated into routine practice.

  20. Deepening structural reform, and speeding up self-reliant nuclear power development

    International Nuclear Information System (INIS)

    Wang Binghua

    2010-01-01

    Combining the implementation practices of the strategy on self-reliant development of the third generation nuclear power plant, the paper set forth that speeding up self-reliant nuclear power development has strategic significance to the national economy and the people's livelihood, which need further deepening structural reform and nuclear power structural reform with an aim to enhance the international competitiveness of China's nuclear industry. (author)

  1. A fast-response production-inventory model for deteriorating seasonal products with learning in set-ups

    Directory of Open Access Journals (Sweden)

    Ibraheem Abdul

    2011-10-01

    Full Text Available The classical production-inventory model assumes that both demand and set-up costs are constant. However, in real manufacturing environment, managers usually embark on continuous improvement programmes that often lead to more effective use of tools and machineries and consequently reduction in set-up costs. In fact, constant emphasis on reduction of set-up costs is usually cited as one of the factors responsible for the efficiency of Japanese manufacturing methods. On the other hand, the demand for seasonal product is often characterized by a mixture of time-dependent patterns over the entire season. This paper investigates the effect of learning-based reduction in set-up costs on the optimal schedules and costs of a production-inventory system for deteriorating seasonal products. The demand pattern is a general three-phase ramp-type demand function that represents the various phases of demand commonly observed in many seasonal products in the market. A two-parameter Weibull-distribution function is used for the deterioration of items in order to make the model more generalized and realistic. The study further presents two different multi-period production strategies that can ensure a fast-response to customers’ demand and compare them with the usual single period strategy. The Numerical example and sensitivity analysis shows that learning-based reduction in set-up costs leads to higher production frequency and shorter production runs which are vital aspects of the just-in-time (JIT philosophy.

  2. Experimental Set-up for Irradiation of Solid H2 and D2 with Charged Particles of keV Energies

    DEFF Research Database (Denmark)

    Sørensen, H.

    1976-01-01

    crystal film thickness monitor. The target plate, which can be heated so that films are removable by evaporation, may be used both as a calorimeter and as a beam current collector. Methods for measurement of secondary electron emission coefficients were developed, and preliminary measurements were made...... with electrons and hydrogen ions. For electron bombardment, the secondary electron emission coefficient of solid deuterium was much smaller than one. It was shown possible to use the set-up to study beam desorption of very thin films. Furthermore the set-up could be used for measuring the energy......An experimental facility was built where films of solid deuterium (and hydrogen) may be made with known thickness and irradiated with pulsed beams of electrons (up to 3 keV) and light ions (up to 10 keV). Films are made on a target plate held at 2.5–3 K. Film growth rate is calibrated with a quartz...

  3. Investigations in quantum games using EPR-type set-ups

    Science.gov (United States)

    Iqbal, Azhar

    2006-04-01

    Research in quantum games has flourished during recent years. However, it seems that opinion remains divided about their true quantum character and content. For example, one argument says that quantum games are nothing but 'disguised' classical games and that to quantize a game is equivalent to replacing the original game by a different classical game. The present thesis contributes towards the ongoing debate about quantum nature of quantum games by developing two approaches addressing the related issues. Both approaches take Einstein-Podolsky-Rosen (EPR)-type experiments as the underlying physical set-ups to play two-player quantum games. In the first approach, the players' strategies are unit vectors in their respective planes, with the knowledge of coordinate axes being shared between them. Players perform measurements in an EPR-type setting and their payoffs are defined as functions of the correlations, i.e. without reference to classical or quantum mechanics. Classical bimatrix games are reproduced if the input states are classical and perfectly anti-correlated, as for a classical correlation game. However, for a quantum correlation game, with an entangled singlet state as input, qualitatively different solutions are obtained. The second approach uses the result that when the predictions of a Local Hidden Variable (LHV) model are made to violate the Bell inequalities the result is that some probability measures assume negative values. With the requirement that classical games result when the predictions of a LHV model do not violate the Bell inequalities, our analysis looks at the impact which the emergence of negative probabilities has on the solutions of two-player games which are physically implemented using the EPR-type experiments.

  4. LightCDD: Application of a Capability-Driven Development Method for Start-ups Development

    Directory of Open Access Journals (Sweden)

    Hasan Koç

    2017-04-01

    Full Text Available Novice innovators and entrepreneurs face the risk of designing naive business models. In fact, lack of viability in business models is perceived to be a major threat for the start-up success. Both the literature and the responses we gathered from experts in incubation present evidences of this problem. The LightCDD method helps entrepreneurs in the analysis, design and specification of start-ups that are context aware and adaptive to contextual changes and evolution. In this article we describe the LightCDD method, a context-aware enterprise modeling method that is tailored for business model generation. The LightCDD applies a lightweight Capability‑Driven Development (CDD methodology. It reduces the set of modeling constructs and guidelines to facilitate its adoption by entrepreneurs, yet keeping it expressive enough for their purposes and, at the same time, compatible with the CDD methodology. We provide a booklet with the LightCDD method for start-ups development. The feasibility of the LightCDD method is validated by means of its application to one start-up development case. From a practitioner viewpoint (entrepreneurs and experts in incubation, it is important to provide integrative modeling perspectives to specify business ideas, but it is vital to keep it light. The LightCDD is giving a step forward in this direction. From a researcher point of view, the LightCDD booklet facilitates the application of LightCDD to different start-up development cases. The feasibility validation has produced important feedback for further empirical validation exercises in which is necessary to study the scalability and sensitivity of LightCDD.

  5. Monte Carlo calculations and neutron spectrometry in quantitative prompt gamma neutron activation analysis (PGNAA) of bulk samples using an isotopic neutron source

    International Nuclear Information System (INIS)

    Spyrou, N.M.; Awotwi-Pratt, J.B.; Williams, A.M.

    2004-01-01

    An activation analysis facility based on an isotopic neutron source (185 GBq 241 Am/Be) which can perform both prompt and cyclic activation analysis on bulk samples, has been used for more than 20 years in many applications including 'in vivo' activation analysis and the determination of the composition of bio-environmental samples, such as, landfill waste and coal. Although the comparator method is often employed, because of the variety in shape, size and elemental composition of these bulk samples, it is often difficult and time consuming to construct appropriate comparator samples for reference. One of the obvious problems is the distribution and energy of the neutron flux in these bulk and comparator samples. In recent years, it was attempted to adopt the absolute method based on a monostandard and to make calculations using a Monte Carlo code (MCNP4C2) to explore this further. In particular, a model of the irradiation facility has been made using the MCNP4C2 code in order to investigate the factors contributing to the quantitative determination of the elemental concentrations through prompt gamma neutron activation analysis (PGNAA) and most importantly, to estimate how the neutron energy spectrum and neutron dose vary with penetration depth into the sample. This simulation is compared against the scattered and transmitted neutron energy spectra that are experimentally and empirically determined using a portable neutron spectrometry system. (author)

  6. Setting up and Running a School Library. Information Collection and Exchange Publication No. ED204

    Science.gov (United States)

    Baird, Nicola

    2012-01-01

    This book explains how teachers can set up and run a successful school library. In it you will find advice and information on how to: (1) set up a small library and build bookshelves; (2) select books for your library; (3) make a written record of your school's books, pamphlets and other library stock such as newspapers, magazines, audio tapes and…

  7. The new cold neutron tomography set-up at SINQ

    CERN Document Server

    Baechler, S; Cauwels, P; Dierick, M; Jolie, J; Materna, T; Mondelaers, W

    2002-01-01

    A new cold neutron tomography set-up is operational at the neutron spallation source SINQ of the Paul Scherrer Institute (PSI) in Villigen, Switzerland. The detection system is based on a sup 6 LiF/ZnS:Ag conversion screen and a CCD camera. Several tests have been carried out to characterize the quality of the tomography system, such as homogeneity, reproducibility, L/D-ratio and spatial resolution. The high flux and the good efficiency of the detector lead to very short exposure times. Thus, a typical set of tomography scans can be performed in only 20 min. Then, 3D computed tomography objects were calculated using the filtered back-projection reconstruction method. Initial results of various samples show that cold neutron tomography can be a useful tool for industry, geology and dentistry. Furthermore, suitable applications can be found in the field of archaeology.

  8. Setting up fuel supply strategies for large-scale bio-energy projects using agricultural and forest residues. A methodology for developing countries

    International Nuclear Information System (INIS)

    Junginger, M.

    2000-08-01

    The objective of this paper is to develop a coherent methodology to set up fuel supply strategies for large-scale biomass-conversion units. This method will explicitly take risks and uncertainties regarding availability and costs in relation to time into account. This paper aims at providing general guidelines, which are not country-specific. These guidelines cannot provide 'perfect fit'-solutions, but aim to give general help to overcome barriers and to set up supply strategies. It will mainly focus on residues from the agricultural and forestry sector. This study focuses on electricity or both electricity and heat production (CHP) with plant scales between 1040 MWe. This range is chosen due to rules of economies of scale. In large-scale plants the benefits of increased efficiency outweigh increased transportation costs, allowing a lower price per kWh which in turn may allow higher biomass costs. However, fuel-supply risks tend to get higher with increasing plant size, which makes it more important to assess them for large(r) conversion plants. Although the methodology does not focus on a specific conversion technology, it should be stressed that the technology must be able to handle a wide variety of biomass fuels with different characteristics because many biomass residues are not available the year round and various fuels are needed for a constant supply. The methodology allows for comparing different technologies (with known investment and operational and maintenance costs from literature) and evaluation for different fuel supply scenarios. In order to demonstrate the methodology, a case study was carried out for the north-eastern part of Thailand (Isaan), an agricultural region. The research was conducted in collaboration with the Regional Wood Energy Development Programme in Asia (RWEDP), a project of the UN Food and Agricultural Organization (FAO) in Bangkok, Thailand. In Section 2 of this paper the methodology will be presented. In Section 3 the economic

  9. Broadband short pulse measurement by autocorrelation with a sum-frequency generation set-up

    International Nuclear Information System (INIS)

    Glotin, F.; Jaroszynski, D.; Marcouille, O.

    1995-01-01

    Previous spectral and laser pulse length measurements carried out on the CLIO FEL at wavelength λ=8.5 μm suggested that very short light pulses could be generated, about 500 fs wide (FWHM). For these measurements a Michelson interferometer with a Te crystal, as a non-linear detector, was used as a second order autocorrelation device. More recent measurements in similar conditions have confirmed that the laser pulses observed are indeed single: they are not followed by other pulses distant by the slippage length Nλ. As the single micropulse length is likely to depend on the slippage, more measurements at different wavelengths would be useful. This is not directly possible with our actual interferometer set-up, based on a phase-matched non-linear crystal. However, we can use the broadband non-linear medium provided by one of our users' experiments: Sum-Frequency Generation over surfaces. With such autocorrelation set-up, interference fringes are no more visible, but this is largely compensated by the frequency range provided. First tests at 8 μm have already been performed to validate the technic, leading to results similar to those obtained with our previous Michelson set-up

  10. Evaluation of errors set-up and setting margins calculation in treatments 3-D conformal radiotherapy; Evaluacion de errores de set-up y calculo de margenes de configuracion en tratamientos de radioterapia CONFORMADA 3-D

    Energy Technology Data Exchange (ETDEWEB)

    Donis, S.; Robayna, B.; Gonzalez, A.; Hernandez Armas, J.

    2011-07-01

    The use of IGRT techniques provide knowledge of the mistakes made in the positioning of a patient, to population studies and estimate the margins for each population.In this paper we evaluate the errors of set-up in 3 different locations and from these margins are calculated configuration (SM).

  11. Mapping Suitable Sites for Setting up Wind Farms: A Case Study of ...

    African Journals Online (AJOL)

    Mapping Suitable Sites for Setting up Wind Farms: A Case Study of Nyanga District. ... Ethiopian Journal of Environmental Studies and Management ... sources and continuous power shortages make wind energy a very attractive alternative to ...

  12. Performance test results of noninvasive characterization of RCRA surrogate waste by prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Propp, W.A.

    1997-11-01

    A performance evaluation to determine the feasibility of using prompt gamma neutron activation analysis (PGNAA) for noninvasive, quantitative assay of mixed waste containers was sponsored by DOE's Office of Technology Development (OTD), the Mixed Waste Focus Area (MWFA), and the Idaho National Engineering and Environmental Laboratory (INEEL). The evaluation was conducted using a surrogate waste, based on Portland cement, that was spiked with three RCRA metals, mercury, cadmium, and lead. The results indicate that PGNAA has potential as a process monitor. However, further development is required to improve its sensitivity to meet regulatory requirements for determination of these RCRA metals

  13. ALBERTA - HEC test beam set-up in June 1999

    CERN Multimedia

    Vinter, M.

    1999-01-01

    Photo1 - HEC 2 (rear) being set up in the "clean" room. Photo2 - HEC 2 (rear) being craned onto rotating C. Photo3 - HEC 2 (rear) being rotated. Photo4 - A now well rotated HEC 2 (rear) is being craned off the C. Photo5 - HEC 2 (rear) installed in the cryostat. Photo6 - Part of the basic frame (the frame that sits in the very bottom of the cryostat). Photo7 - Part of the basic frame (one of the two frames which the 3 calorimeter modules sit on). Photo8 - The marriage frame.

  14. On the Optimal Policy for the Single-product Inventory Problem with Set-up Cost and a Restricted Production Capacity

    NARCIS (Netherlands)

    Foreest, N. D. van; Wijngaard, J.

    2010-01-01

    The single-product, stationary inventory problem with set-up cost is one of the classical problems in stochastic operations research. Theories have been developed to cope with finite production capacity in periodic review systems, and it has been proved that optimal policies for these cases are not

  15. A new small-angle X-ray scattering set-up on the crystallography beamline I711 at MAX-lab

    DEFF Research Database (Denmark)

    Knaapila, M.; Svensson, C.; Barauskas, J.

    2009-01-01

    A small-angle X-ray scattering (SAXS) set-up has recently been developed at beamline I711 at the MAX II storage ring in Lund (Sweden). An overview of the required modifications is presented here together with a number of application examples. The accessible q range in a SAXS experiment is 0.009-0...

  16. A managed clinical network for cardiac services: set-up, operation and impact on patient care

    Directory of Open Access Journals (Sweden)

    Karen E. Hamilton

    2005-09-01

    Full Text Available Purpose: To investigate the set up and operation of a Managed Clinical Network for cardiac services and assess its impact on patient care. Methods: This single case study used process evaluation with observational before and after comparison of indicators of quality of care and costs. The study was conducted in Dumfries and Galloway, Scotland and used a three-level framework. Process evaluation of the network set-up and operation through a documentary review of minutes; guidelines and protocols; transcripts of fourteen semi-structured interviews with health service personnel including senior managers, general practitioners, nurses, cardiologists and members of the public. Outcome evaluation of the impact of the network through interrupted time series analysis of clinical data of 202 patients aged less than 76 years admitted to hospital with a confirmed myocardial infarction one-year pre and one-year post, the establishment of the network. The main outcome measures were differences between indicators of quality of care targeted by network protocols. Economic evaluation of the transaction costs of the set-up and operation of the network and the resource costs of the clinical care of the 202 myocardial infarction patients from the time of hospital admission to 6 months post discharge through interrupted time series analysis. The outcome measure was different in National Health Service resource use. Results: Despite early difficulties, the network was successful in bringing together clinicians, patients and managers to redesign services, exhibiting most features of good network management. The role of the energetic lead clinician was crucial, but the network took time to develop and ‘bed down’. Its primary “modus operand” was the development of a myocardial infarction pathway and associated protocols. Of sixteen clinical care indicators, two improved significantly following the launch of the network and nine showed improvements, which were

  17. A simple and convenient set-up for high-temperature Brillouin light scattering

    International Nuclear Information System (INIS)

    Guerette, Michael; Huang Liping

    2012-01-01

    An emulated platelet geometry (or reflection-induced platelet geometry) is employed to collect photons scattered from both longitudinal and transverse acoustic waves travelling within a bulk transparent sample sitting on a reflective Pt plate. Temperature of the sample was controlled with a Linkam TS1500 optical furnace (maximum temperature of 1500 °C). This simple and convenient set-up allows a full determination of elastic constants of transparent materials in situ as a function of temperature from Brillouin light scattering. Structural information can be gained at the same time by guiding the scattered light into a Raman spectrometer using a flipping mirror or a beam splitter. We will demonstrate the applications of this set-up in transparent inorganic glasses, but it can be easily extended to any other transparent materials, either crystalline or amorphous in nature. (paper)

  18. Automation and robotization of the set-up and treatment for patients treated for a brain and base of the skull tumor

    International Nuclear Information System (INIS)

    Noel, G.; Ferrand, R.; Feuvret, L.; Meyroneinc, S.; Mazeron, J.J.; Boisserie, G.; Mazeron, J.J.

    2003-01-01

    Progresses of the three-dimensional imageries and of the software of planning systems makes that the radiotherapy of the tumours of brain and the base of skull is increasingly precise. The set-up of the patients and the positioning of the beams are key acts whose realization can become extremely tiresome if the requirement of precision increases. This precision very often rests still on the visual comparison of digital images. In the near future, the development of the automated systems controlled by robots should allow a noticeable improvement of the precision, safety and speed of the patient set-up. (author)

  19. Monitoring electro-magnetic field in urban areas: new set-ups and results

    Energy Technology Data Exchange (ETDEWEB)

    Lubritto, C.; Petraglia, A.; Paribello, G.; Formosi, R.; Rosa, M. de; Vetromile, C.; Palmieri, A.; D' Onofrio, A. [Seconda Universita di Napoli, Dipt. di Scienze Ambientali, Caserta (Italy); Di Bella, G.; Giannini, V. [Vector Group, Roma (Italy)

    2006-07-01

    In this paper two different set-ups for continuous monitoring of electromagnetic levels are presented: the first one (Continuous Time E.M.F. Monitoring System) is based upon a network of fixed stations, allowing a detailed field monitoring as function of the time; the second one (Mobile Measurements Units) resorts to portable stations mounted on standard bicycles, allowing a positional screening in limited time intervals. For both set-ups a particular attention has been paid to the data management, by means of tools like web geographic information systems (Web-Gis). Moreover the V.I.C.R.E.M./E.L.F. software has been used for a predictive analysis of the electromagnetic field levels along with the geo referenced data coming from the field measurements. Starting from these results it has been realized that there is a need for an efficient and correct action of monitoring and information/formation in this domain, where dis-information or bad information is very often spread in the population, in particular in a field where the process of the appreciation and assessment of risk does not necessarily make use of a rationale, technically-informed procedure, but the judgement is rather based on a personal feeling, which may derive from a limited, unstructured set of information, using a set of qualitative attributes rather than a quantity. (N.C.)

  20. Monitoring electro-magnetic field in urban areas: new set-ups and results

    International Nuclear Information System (INIS)

    Lubritto, C.; Petraglia, A.; Paribello, G.; Formosi, R.; Rosa, M. de; Vetromile, C.; Palmieri, A.; D'Onofrio, A.; Di Bella, G.; Giannini, V.

    2006-01-01

    In this paper two different set-ups for continuous monitoring of electromagnetic levels are presented: the first one (Continuous Time E.M.F. Monitoring System) is based upon a network of fixed stations, allowing a detailed field monitoring as function of the time; the second one (Mobile Measurements Units) resorts to portable stations mounted on standard bicycles, allowing a positional screening in limited time intervals. For both set-ups a particular attention has been paid to the data management, by means of tools like web geographic information systems (Web-Gis). Moreover the V.I.C.R.E.M./E.L.F. software has been used for a predictive analysis of the electromagnetic field levels along with the geo referenced data coming from the field measurements. Starting from these results it has been realized that there is a need for an efficient and correct action of monitoring and information/formation in this domain, where dis-information or bad information is very often spread in the population, in particular in a field where the process of the appreciation and assessment of risk does not necessarily make use of a rationale, technically-informed procedure, but the judgement is rather based on a personal feeling, which may derive from a limited, unstructured set of information, using a set of qualitative attributes rather than a quantity. (N.C.)

  1. Investigation on Superior Performance by Fractional Controller for Cart-Servo Laboratory Set-Up

    Directory of Open Access Journals (Sweden)

    Ameya Anil Kesarkar

    2014-01-01

    Full Text Available In this paper, an investigation is made on the superiority of fractional PID controller (PI^alpha D^beta over conventional PID for the cart-servo laboratory set-up. The designed controllers are optimum in the sense of Integral Absolute Error (IAE and Integral Square Error (ISE. The paper contributes in three aspects: 1 Acquiring nonlinear mathematical model for the cart-servo laboratory set-up, 2 Designing fractional and integer order PID for minimizing IAE, ISE, 3 Analyzing the performance of designed controllers for simulated plant model as well as real plant. The results show a significantly superior performance by PI^alpha D^beta as compared to the conventional PID controller.

  2. On the accuracy of protein determination in large biological samples by prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Kasviki, K.; Stamatelatos, I.E.; Yannakopoulou, E.; Papadopoulou, P.; Kalef-Ezra, J.

    2007-01-01

    A prompt gamma neutron activation analysis (PGNAA) facility has been developed for the determination of nitrogen and thus total protein in large volume biological samples or the whole body of small animals. In the present work, the accuracy of nitrogen determination by PGNAA in phantoms of known composition as well as in four raw ground meat samples of about 1 kg mass was examined. Dumas combustion and Kjeldahl techniques were also used for the assessment of nitrogen concentration in the meat samples. No statistically significant differences were found between the concentrations assessed by the three techniques. The results of this work demonstrate the applicability of PGNAA for the assessment of total protein in biological samples of 0.25-1.5 kg mass, such as a meat sample or the body of small animal even in vivo with an equivalent radiation dose of about 40 mSv

  3. On the accuracy of protein determination in large biological samples by prompt gamma neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kasviki, K. [Institute of Nuclear Technology and Radiation Protection, NCSR ' Demokritos' , Aghia Paraskevi, Attikis 15310 (Greece); Medical Physics Laboratory, Medical School, University of Ioannina, Ioannina 45110 (Greece); Stamatelatos, I.E. [Institute of Nuclear Technology and Radiation Protection, NCSR ' Demokritos' , Aghia Paraskevi, Attikis 15310 (Greece)], E-mail: ion@ipta.demokritos.gr; Yannakopoulou, E. [Institute of Physical Chemistry, NCSR ' Demokritos' , Aghia Paraskevi, Attikis 15310 (Greece); Papadopoulou, P. [Institute of Technology of Agricultural Products, NAGREF, Lycovrissi, Attikis 14123 (Greece); Kalef-Ezra, J. [Medical Physics Laboratory, Medical School, University of Ioannina, Ioannina 45110 (Greece)

    2007-10-15

    A prompt gamma neutron activation analysis (PGNAA) facility has been developed for the determination of nitrogen and thus total protein in large volume biological samples or the whole body of small animals. In the present work, the accuracy of nitrogen determination by PGNAA in phantoms of known composition as well as in four raw ground meat samples of about 1 kg mass was examined. Dumas combustion and Kjeldahl techniques were also used for the assessment of nitrogen concentration in the meat samples. No statistically significant differences were found between the concentrations assessed by the three techniques. The results of this work demonstrate the applicability of PGNAA for the assessment of total protein in biological samples of 0.25-1.5 kg mass, such as a meat sample or the body of small animal even in vivo with an equivalent radiation dose of about 40 mSv.

  4. System Administrator for LCS Development Sets

    Science.gov (United States)

    Garcia, Aaron

    2013-01-01

    The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.

  5. Experimental set-up for advanced aeroelastic tests on sectional models

    Czech Academy of Sciences Publication Activity Database

    Král, Radomil; Pospíšil, Stanislav; Náprstek, Jiří

    2016-01-01

    Roč. 40, č. 1 (2016), s. 3-13 ISSN 0732-8818 R&D Projects: GA ČR GA103/09/0094; GA AV ČR IAA200710902; GA MŠk(CZ) ED1.1.00/02.0060 Institutional support: RVO:68378297 Keywords : bridge aeroelasticity * wind tunnel * experimental set-up * non- linear response Subject RIV: JM - Building Engineering Impact factor: 0.932, year: 2016 http://link.springer.com/article/10.1007%2Fs40799-015-0004-6

  6. Experimental Study of Drag Resistance using a Laboratory Scale Rotary Set-Up

    DEFF Research Database (Denmark)

    Erik Weinell, Claus; Olsen, Kenneth N.; Christoffersen, Martin W.

    2003-01-01

    This work covers an experimental study of the drag resistance of different painted surfaces and simulated large-scale irregularities, viz. dry spraying, weld seams, barnacle fouling and paint remains. A laboratory scale rotary set-up was used to determine the drag resistance, and the surface...

  7. Methodology for Quantitative Analysis of Large Liquid Samples with Prompt Gamma Neutron Activation Analysis using Am-Be Source

    International Nuclear Information System (INIS)

    Idiri, Z.; Mazrou, H.; Beddek, S.; Amokrane, A.

    2009-01-01

    An optimized set-up for prompt gamma neutron activation analysis (PGNAA) with Am-Be source is described and used for large liquid samples analysis. A methodology for quantitative analysis is proposed: it consists on normalizing the prompt gamma count rates with thermal neutron flux measurements carried out with He-3 detector and gamma attenuation factors calculated using MCNP-5. The relative and absolute methods are considered. This methodology is then applied to the determination of cadmium in industrial phosphoric acid. The same sample is then analyzed by inductively coupled plasma (ICP) method. Our results are in good agreement with those obtained with ICP method.

  8. Standard guidelines for setting up a dermatosurgery theatre

    Directory of Open Access Journals (Sweden)

    Rajendran S

    2009-08-01

    Full Text Available Introduction, definition, rationale and scope: Dermatologists in India are now increasingly performing surgical and cosmetic procedures in their practice. This calls for minimum standards at the national level with the main focus of patient safety and hence the guidelines for setting up a dermatosurgical theatre. Facility: The dermatosurgery theatre can be created in either physician′s clinic, or a hospital depending on the procedure to be performed. The dermatosurgery theatre requires careful planning with regards to - location, dimension, shell design, lighting, electrical requirements, operation table, chair, trolley, surgical instruments, sterilization of devices, asepsis and advanced life support. Apart from physical considerations, other considerations including theatre etiquettes, consent for surgery, safety of dermatosurgeon, theatre staff and lastly biomedical waste management should be looked into. These issues are discussed in detail in the recommendations.

  9. Goal Setting as Teacher Development Practice

    Science.gov (United States)

    Camp, Heather

    2017-01-01

    This article explores goal setting as a teacher development practice in higher education. It reports on a study of college teacher goal setting informed by goal setting theory. Analysis of study participants' goal setting practices and their experiences with goal pursuit offers a framework for thinking about the kinds of goals teachers might set…

  10. Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images

    International Nuclear Information System (INIS)

    Bijhold, J.; Herk, M. van; Vijlbrief, R.; Lebesque, J.V.

    1991-01-01

    A new fast method is presented for the quantification of patient set-up errors during radiotherapy with external photon beams. The set-up errors are described as deviations in relative position and orientation of specified anatomical structures relative to specified field shaping devices. These deviations are determined from parameters of the image transformations that make their features in a portal image align with the corresponding features in a simulator image. Knowledge of some set-up parameters during treatment simulation is required. The method does not require accurate knowledge about the position of the portal imaging device as long as the positions of some of the field shaping devices are verified independently during treatment. By applying this method, deviations in a pelvic phantom set-up can be measured with a precision of 2 mm within 1 minute. Theoretical considerations and experiments have shown that the method is not applicable when there are out-of-plane rotations larger than 2 degrees or translations larger than 1 cm. Inter-observer variability proved to be a source of large systematic errors, which could be reduced by offering a precise protocol for the feature alignment. (author)

  11. New large solar photocatalytic plant: set-up and preliminary results.

    Science.gov (United States)

    Malato, S; Blanco, J; Vidal, A; Fernández, P; Cáceres, J; Trincado, P; Oliveira, J C; Vincent, M

    2002-04-01

    A European industrial consortium called SOLARDETOX has been created as the result of an EC-DGXII BRITE-EURAM-III-financed project on solar photocatalytic detoxification of water. The project objective was to develop a simple, efficient and commercially competitive water-treatment technology, based on compound parabolic collectors (CPCs) solar collectors and TiO2 photocatalysis, to make possible easy design and installation. The design, set-up and preliminary results of the main project deliverable, the first European industrial solar detoxification treatment plant, is presented. This plant has been designed for the batch treatment of 2 m3 of water with a 100 m2 collector-aperture area and aqueous aerated suspensions of polycrystalline TiO2 irradiated by sunlight. Fully automatic control reduces operation and maintenance manpower. Plant behaviour has been compared (using dichloroacetic acid and cyanide at 50 mg l(-1) initial concentration as model compounds) with the small CPC pilot plants installed at the Plataforma Solar de Almería several years ago. The first results with high-content cyanide (1 g l(-1)) waste water are presented and plant treatment capacity is calculated.

  12. Set up for Success: An Examination of the Ronald E. McNair Postbaccalaureate Achievement Program's Mentoring Component

    Science.gov (United States)

    Wyre, Dwuena Cene

    2011-01-01

    Often, individuals are set up to fail. However, effective mentoring can set individuals up to succeed. This nonexperimental cross-sectional, predictive study examines the Ronald E. McNair Postbaccalaureate Achievement Program's mentoring component. Specific focus is placed on faculty mentor competency and its impact on McNair student intent to…

  13. A Python tool to set up relative free energy calculations in GROMACS.

    Science.gov (United States)

    Klimovich, Pavel V; Mobley, David L

    2015-11-01

    Free energy calculations based on molecular dynamics (MD) simulations have seen a tremendous growth in the last decade. However, it is still difficult and tedious to set them up in an automated manner, as the majority of the present-day MD simulation packages lack that functionality. Relative free energy calculations are a particular challenge for several reasons, including the problem of finding a common substructure and mapping the transformation to be applied. Here we present a tool, alchemical-setup.py, that automatically generates all the input files needed to perform relative solvation and binding free energy calculations with the MD package GROMACS. When combined with Lead Optimization Mapper (LOMAP; Liu et al. in J Comput Aided Mol Des 27(9):755-770, 2013), recently developed in our group, alchemical-setup.py allows fully automated setup of relative free energy calculations in GROMACS. Taking a graph of the planned calculations and a mapping, both computed by LOMAP, our tool generates the topology and coordinate files needed to perform relative free energy calculations for a given set of molecules, and provides a set of simulation input parameters. The tool was validated by performing relative hydration free energy calculations for a handful of molecules from the SAMPL4 challenge (Mobley et al. in J Comput Aided Mol Des 28(4):135-150, 2014). Good agreement with previously published results and the straightforward way in which free energy calculations can be conducted make alchemical-setup.py a promising tool for automated setup of relative solvation and binding free energy calculations.

  14. The pattern of trauma in private general medical practice set-up Port ...

    African Journals Online (AJOL)

    BACKGROUND: Private general medical practice establishments appear to be treating a significant number of trauma cases including more serious ones. Aim: To find out the extent of such treatment of trauma and what has made this possible. METHODS: All trauma cases treated in a private general medical practice set up ...

  15. Secondary electron images obtained with a standard PEEM set up

    International Nuclear Information System (INIS)

    Benka, O.; Zeppenfeld, P.

    2004-01-01

    Secondary electron images excited by 3 to 4.3 keV electrons are obtained with a standard photoelectron electron emission microscope (PEEM) set up equipped with an imaging energy filter (IEF). The electron gun was mounted on a standard PEEM entrance flange at an angle of 25 o with respect to the sample surface. A low extraction voltage of 500 V was used to minimize the deflection of the electron beam by the PEEM extraction electrode. The secondary electron images are compared to photoelectron images excited by a standard 4.9 eV UV lamp. In the case of a Cu pattern on a Si substrate it is found that the lateral resolution without the IEF is about the same for electron and photon excitation but that the relative electron emission intensities are very different. The use of the IEF-reduces the lateral resolution. Images for secondary electron energies between eV 1 and eV 2 were obtained by setting the IEF to -V 1 and -V 2 ∼ -(V 1 + 5V) potentials and taking the difference of both images. Images up to 100 eV electron energies were recorded. The lateral resolution is in the range of μm. The material contrast obtained in these difference images are discussed in terms of a secondary electron and photoelectron emission model and secondary electron energy spectra measured with a LEED-Auger spectrometer. (author)

  16. Report on the set-up of a holographic interferometer

    International Nuclear Information System (INIS)

    Koster, J.N.

    1977-10-01

    Holographic interferometry is well suited for visualizing temperature, density, pressure and concentration fields in transparent fluids. The holographic real-time interferometer allows a continuous observation of stationary and instationary flow processes. After the explanation of the measuring technique, the problems arising during the interferometer set-up as well as the necessary adjusting operations are described. For heat transfer problems new possibilities for the application of holographic interferometry are revealed. Convection in boxes, temperature fields around heated or cooled bodies, concentration and diffusion processes in two phase-flows, mixtures and solutions as well as melting and freezing processes may be investigated. On the basis of particular examples some applications are presented. (orig.) [de

  17. A strategy to improve priority setting in developing countries.

    Science.gov (United States)

    Kapiriri, Lydia; Martin, Douglas K

    2007-09-01

    Because the demand for health services outstrips the available resources, priority setting is one of the most difficult issues faced by health policy makers, particularly those in developing countries. Priority setting in developing countries is fraught with uncertainty due to lack of credible information, weak priority setting institutions, and unclear priority setting processes. Efforts to improve priority setting in these contexts have focused on providing information and tools. In this paper we argue that priority setting is a value laden and political process, and although important, the available information and tools are not sufficient to address the priority setting challenges in developing countries. Additional complementary efforts are required. Hence, a strategy to improve priority setting in developing countries should also include: (i) capturing current priority setting practices, (ii) improving the legitimacy and capacity of institutions that set priorities, and (iii) developing fair priority setting processes.

  18. Automotive RF immunity test set-up analysis : why test results can't compare

    NARCIS (Netherlands)

    Coenen, Mart; Pues, H.; Bousquet, T.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  19. Evaluation of different set-up error corrections on dose-volume metrics in prostate IMRT using CBCT images

    International Nuclear Information System (INIS)

    Hirose, Yoshinori; Tomita, Tsuneyuki; Kitsuda, Kenji; Notogawa, Takuya; Miki, Katsuhito; Nakamura, Mitsuhiro; Nakamura, Kiyonao; Ishigaki, Takashi

    2014-01-01

    We investigated the effect of different set-up error corrections on dose-volume metrics in intensity-modulated radiotherapy (IMRT) for prostate cancer under different planning target volume (PTV) margin settings using cone-beam computed tomography (CBCT) images. A total of 30 consecutive patients who underwent IMRT for prostate cancer were retrospectively analysed, and 7-14 CBCT datasets were acquired per patient. Interfractional variations in dose-volume metrics were evaluated under six different set-up error corrections, including tattoo, bony anatomy, and four different target matching groups. Set-up errors were incorporated into planning the isocenter position, and dose distributions were recalculated on CBCT images. These processes were repeated under two different PTV margin settings. In the on-line bony anatomy matching groups, systematic error (Σ) was 0.3 mm, 1.4 mm, and 0.3 mm in the left-right, anterior-posterior (AP), and superior-inferior directions, respectively. Σ in three successive off-line target matchings was finally comparable with that in the on-line bony anatomy matching in the AP direction. Although doses to the rectum and bladder wall were reduced for a small PTV margin, averaged reductions in the volume receiving 100% of the prescription dose from planning were within 2.5% under all PTV margin settings for all correction groups, with the exception of the tattoo set-up error correction only (≥ 5.0%). Analysis of variance showed no significant difference between on-line bony anatomy matching and target matching. While variations between the planned and delivered doses were smallest when target matching was applied, the use of bony anatomy matching still ensured the planned doses. (author)

  20. Setting up a randomized clinical trial in the UK: approvals and process.

    Science.gov (United States)

    Greene, Louise Eleanor; Bearn, David R

    2013-06-01

    Randomized clinical trials are considered the 'gold standard' in primary research for healthcare interventions. However, they can be expensive and time-consuming to set up and require many approvals to be in place before they can begin. This paper outlines how to determine what approvals are required for a trial, the background of each approval and the process for obtaining them.

  1. Act No. 15 of 22 April 1980 setting up the Nuclear Safety Council

    International Nuclear Information System (INIS)

    1980-01-01

    The Spanish authorities are in the process or reorganising the public nuclear sector in order to separate the promotional and research aspects of the uses of nuclear energy for peaceful purposes from the regulation and control of such activities. To this effect this Act sets up a Nuclear Safety Council which takes over part of the duties and the personnel of the Junta de Energia Nuclear provided for by the Act of 29th April 1964 on Nuclear Energy. The new Nuclear Safety Council is a body which is independent of the State central administration and has legal personality as well as its own financial resources required to carry out its duties. The latter comprise, inter alia, proposing to the Government the regulations required in matters of nuclear safety and radiation protection; this includes the setting-up of standards and criteria for the selection of nuclear installation sites, in consultation with the local competent bodies. (NEA) [fr

  2. Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Song, William; Lau, Harold; Dunscombe, Peter

    2005-01-01

    The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either surface contours or internal inhomogeneities, both of which are highly relevant to sites in the head and neck, we have employed the more resource intensive direct simulation method. The impact of both systematic (variable from 0 to 6 mm) and random (fixed at 2 mm) set-up uncertainties on compliance with the criteria of the RTOG H-0022 protocol has been examined for eight geometrically complex structures: CTV66 (gross tumour volume and palpable lymph nodes suspicious for metastases), CTV54 (lymph node groups or surgical neck levels at risk of subclinical metastases), glottic larynx, spinal cord, brainstem, mandible and left and right parotids. In a probability-based approach, both dose-volume histograms and equivalent uniform doses were used to describe the dose distributions achieved by plans for two patients, in the presence of set-up uncertainty. The equivalent uniform dose is defined to be that dose which, when delivered uniformly to the organ of interest, will lead to the same response as the non-uniform dose under consideration. For systematic set-up uncertainties greater than 2 mm and 5 mm respectively, coverage of the CTV66 and CTV54 could be significantly compromised. Directional sensitivity was observed in both cases. Most organs at risk (except the glottic larynx which did not comply under static conditions) continued to meet the dose constraints up to 4 mm systematic uncertainty for both plans. The exception was the contra lateral parotid gland, which this protocol is specifically designed to protect. Sensitivity to systematic set-up uncertainty of 2 mm was observed for this organ at risk in both clinical plans

  3. Evaluating Speed Enforcement Field Set-Ups Used by Regional Police in Belgium: An Analysis of Speed Outcome Indicators

    Directory of Open Access Journals (Sweden)

    Brenda Wilmots

    2016-12-01

    Full Text Available In this paper the results from a field experiment (conducted in 2012 are presented, in which 3 regional police units in the Flemish region of Belgium each tested a particular combination of a speed control (with mobile radar in an anonymous car with communicative signage. The goal of this paper was to scientifically evaluate frequently used field set-ups. The following set-ups were tested in one week: (1 police unit 1: speed control with and without a static feedback sign placed after the control; (2 police unit 2: speed control with and without a digital feedback sign placed after the control; (3 police unit 3: speed display followed by a second speed display further along the road section. During certain time frames, speed control took place in between both signs. All tested field set-ups generated significant reductions in the speed level. Studying the effect of the different variations for each set-up reveals that the effect of the speed control is generally larger in combination with the signage alongside the road. After the period during which the police activities took place, speed levels again reached their initial level. Based on the before–after analysis, only in police area 2 was a small ‘time halo-effect’ found. To generalize results from this pilot study, repetition of tested set-ups in the field is recommended as well as testing on a larger scale.

  4. Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis

    International Nuclear Information System (INIS)

    Pallotta, Stefania; Bucciolini, Marta; Vanzi, Eleonora; Marrazzo, Livia; Simontacchi, Gabriele; Paiar, Fabiola; Ceroti, Marco; Livi, Lorenzo

    2015-01-01

    The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57 % of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73 % of the cases, while the use of SA was beneficial in only 45 %. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions. (orig.) [de

  5. Setting up and performance of a laser enhanced ionisation spectrometer

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Razvi, M.A.N.

    1990-01-01

    A laser enhanced ionisation (LEI) spectrometer has been successfuly set up around an excimer laser pumped dye laser. The performance of the spectrometer has been tested by analysing sodium in water solutions. A straight line working curve has been obtained in the concentration range of 1-1000 ng/ml of Na. The effect of parameters like laser power, ion collector electrode voltage and the load resistance on LEI signals has been investigated. The spectrometer is useful not only for analytical purposes but also for laser spectroscopic studies of species formed in flames, study of phenomenon of combustion etc. (author). 1 tab ., 10 figs., 5 refs

  6. Setting up a hydrological model based on global data for the Ayeyarwady basin in Myanmar

    Science.gov (United States)

    ten Velden, Corine; Sloff, Kees; Nauta, Tjitte

    2017-04-01

    The use of global datasets in local hydrological modelling can be of great value. It opens up the possibility to include data for areas where local data is not or only sparsely available. In hydrological modelling the existence of both static physical data such as elevation and land use, and dynamic meteorological data such as precipitation and temperature, is essential for setting up a hydrological model, but often such data is difficult to obtain at the local level. For the Ayeyarwady catchment in Myanmar a distributed hydrological model (Wflow: https://github.com/openstreams/wflow) was set up with only global datasets, as part of a water resources study. Myanmar is an emerging economy, which has only recently become more receptive to foreign influences. It has a very limited hydrometeorological measurement network, with large spatial and temporal gaps, and data that are of uncertain quality and difficult to obtain. The hydrological model was thus set up based on resampled versions of the SRTM digital elevation model, the GlobCover land cover dataset and the HWSD soil dataset. Three global meteorological datasets were assessed and compared for use in the hydrological model: TRMM, WFDEI and MSWEP. The meteorological datasets were assessed based on their conformity with several precipitation station measurements, and the overall model performance was assessed by calculating the NSE and RVE based on discharge measurements of several gauging stations. The model was run for the period 1979-2012 on a daily time step, and the results show an acceptable applicability of the used global datasets in the hydrological model. The WFDEI forcing dataset gave the best results, with a NSE of 0.55 at the outlet of the model and a RVE of 8.5%, calculated over the calibration period 2006-2012. As a general trend the modelled discharge at the upstream stations tends to be underestimated, and at the downstream stations slightly overestimated. The quality of the discharge measurements

  7. An unconventional set-up for fluxless brazing of aluminium

    CERN Document Server

    Loos, Robert

    1999-01-01

    In order to successfully braze aluminium alloy assemblies without the use of oxide-removing fluxes, an evironment with very low contaminant level is mandatory. This is mostly achieved by using a vacuum furnace. Brazing under inert gas of sufficient purity is also possible. The method reported upon here makes use of a stainless steel bag which can enter a traditional air furnace. The bag is evacuated, giving a well distributed mechanical pressure on the parts to join. The intrinsic handicap of poor vacuum is compensated by regular inert gas flushing, even at high temperatures. The set-up works rather well, and the idea is believed to yield a valuable strategic and economic option, for the realization of special equipment as well as for prototyping work. We intend to use the principle for the CMS Preshower cooling screens.

  8. Next steps in the development of ecological soil clean-up values for metals.

    Science.gov (United States)

    Wentsel, Randall; Fairbrother, Anne

    2014-07-01

    This special series in Integrated Environmental Assessment Management presents the results from 6 workgroups that were formed at the workshop on Ecological Soil Levels-Next Steps in the Development of Metal Clean-Up Values (17-21 September 2012, Sundance, Utah). This introductory article presents an overview of the issues assessors face when conducting risk assessments for metals in soils, key US Environmental Protection Agency (USEPA) documents on metals risk assessment, and discusses the importance of leveraging from recent major terrestrial research projects, primarily to address Registration, Evaluation, Authorization and Restriction of Chemical Substances (REACH) requirements in Europe, that have significantly advanced our understanding of the behavior and toxicity of metals in soils. These projects developed large data sets that are useful for the risk assessment of metals in soil environments. The workshop attendees met to work toward developing a process for establishing ecological soil clean-up values (Eco-SCVs). The goal of the workshop was to progress from ecological soil screening values (Eco-SSLs) to final clean-up values by providing regulators with the methods and processes to incorporate bioavailability, normalize toxicity thresholds, address food-web issues, and incorporate background concentrations. The REACH data sets were used by workshop participants as case studies in the development of the ecological standards for soils. The workshop attendees discussed scientific advancements in bioavailability, soil biota and wildlife case studies, soil processes, and food-chain modeling. In addition, one of the workgroups discussed the processes needed to frame the topics to gain regulatory acceptance as a directive or guidance by Canada, the USEPA, or the United States. © 2013 SETAC.

  9. Set-up and Test Procedure for Suction Installation and Uninstallation of Bucket Foundation

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna

    This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use of......) and loading frame used for those tests have been already used for axially static and cyclic loading of piles (Thomassen, 2015a) and for axially static and cyclic loading of bucket foundation (Vaitkunaite et al., 2015).......This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use...... of suction under the bucket lid or by applying additional force through the hydraulic piston, forcing the bucket to penetrate into the soil. Tests for uninstallation are performed also with the use of water pressure, as a reverse process to the suction installation. Both installation and uninstallation tests...

  10. Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

    International Nuclear Information System (INIS)

    Gupta, Tejpal; Chopra, Supriya; Kadam, Avinash; Agarwal, Jai Prakash; Devi, P Reena; Ghosh-Laskar, Sarbani; Dinshaw, Ketayun Ardeshir

    2007-01-01

    Set-up errors are an inherent part of radiation treatment process. Coverage of target volume is a direct function of set-up margins, which should be optimized to prevent inadvertent irradiation of adjacent normal tissues. The aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for target volume coverage in head and neck radiotherapy. The dataset consisted of 93 pairs of orthogonal simulator and corresponding portal images on which 558 point positions were measured to calculate translational displacement in 25 patients undergoing conventional head and neck radiotherapy with antero-lateral wedge pair technique. Mean displacements, population systematic (Σ) and random (σ) errors and 3D vector of displacement was calculated. Set-up margins were calculated using published margin recipes. The mean displacement in antero-posterior (AP), medio-lateral (ML) and supero-inferior (SI) direction was -0.25 mm (-6.50 to +7.70 mm), -0.48 mm (-5.50 to +7.80 mm) and +0.45 mm (-7.30 to +7.40 mm) respectively. Ninety three percent of the displacements were within 5 mm in all three cardinal directions. Population systematic (Σ) and random errors (σ) were 0.96, 0.98 and 1.20 mm and 1.94, 1.97 and 2.48 mm in AP, ML and SI direction respectively. The mean 3D vector of displacement was 3.84 cm. Using van Herk's formula, the clinical target volume to planning target volume margins were 3.76, 3.83 and 4.74 mm in AP, ML and SI direction respectively. The present study report compares well with published set-up error data relevant to head and neck radiotherapy practice. The set-up margins were <5 mm in all directions. Caution is warranted against adopting generic margin recipes as different margin generating recipes lead to a different probability of target volume coverage

  11. Experimental set-up for electrical resistivity measurements at low temperature in amorphous and crystalline metallic samples

    International Nuclear Information System (INIS)

    Rodriquez Fernandez, J.M.; Lopez Sanchez, R.J.; Gomez-Sal, J.C.

    1986-01-01

    The experimental set-up to measure the thermal variation of the electrical resistivity between 10.5 K and 300 K, has been developed. A four probe A.C. method with a synchronous-detection (lock'in) technique were the idoneous for our proposes. We have designed a new type of pressure sample-holder adopted to the CS-202 type cryostat. The measurements performed on samples already known have allowed us to determine the sensitivity of our experiments, which is Δ ρ/ρ=2x10 -4 . The measurements performed in the new Y 3 Rh 2 Si 2 compound which at 10 K has no magnetic ordering, are also presented. (author)

  12. Neutron polarizing set-up of the Sofia IRT research reactor

    International Nuclear Information System (INIS)

    Krezhov, K.; Mikhajlova, V.; Okorokov, A.

    1990-01-01

    Neutron polarizing set-up of one of the horizontal beam tubes of the IRT-200 research reactor of the Bulgarian Institute of Nuclear Research and Nuclear Energy is presented. Neutron mirrors are extensively used in an effort to compensate the moderate reactor beam intensity by the high reflected intensity and wide-band transmittance of the mirror neutron guides. Time-to-flight technique using a slotted neutron absorbing chopper with a horizontal rotation axis has been applied to obtain the exit neutron spectra. Beam polarization and flipping ratios have been determined. Cadmium ratio in the polarized beam has been found almost 10 4 and the average polarization has been measured to be higher than 96%. 3 figs, 3 refs

  13. Early College for All: Efforts to Scale up Early Colleges in Multiple Settings

    Science.gov (United States)

    Edmunds, Julie A.

    2016-01-01

    Given the positive impacts of the small, stand-alone early college model and the desire to provide those benefits to more students, organizations have begun efforts to scale up the early college model in a variety of settings. These efforts have been supported by the federal government, particularly by the Investing in Innovation (i3) program.…

  14. The Impact of use of Double Set-up on Infection Rates in Revision Total Knee Replacement and Limb Salvage Procedures

    Directory of Open Access Journals (Sweden)

    Jennifer Waterman

    2015-03-01

    Full Text Available A retrospective analysis was performed to determine the impact of utilizing a double set-up procedure on reducing infection rates revision total knee and limb salvage procedures in patients with known joint infection.  Eighteen cases fit selection criteria.  The recurrence rate of infection was 5.5% which is less than reported recent literature review.   This suggests the use of a double set-up in combination with other infection reducing protocols may help further reduce recurrent infection.  Keywords: double set-up, infection, revision total knee arthroplasty, limb-salvage

  15. Development of an Educational Game to Set Up Surgical Instruments on the Mayo Stand or Back Table: Applied Research in Production Technology.

    Science.gov (United States)

    Paim, Crislaine Pires Padilha; Goldmeier, Silvia

    2017-01-10

    Existing research suggests that digital games can be used effectively for educational purposes at any level of training. Perioperative nursing educators can use games to complement curricula, in guidance and staff development programs, to foster team collaboration, and to give support to critical thinking in nursing practice because it is a complex environment. To describe the process of developing an educational game to set up surgical instruments on the Mayo stand or back table as a resource to assist the instructor in surgical instrumentation training for students and nursing health professionals in continued education. The study was characterized by applied research in production technology. It included the phases of analysis and design, development, and evaluation. The objectives of the educational game were developed through Bloom's taxonomy. Parallel to the physical development of the educational game, a proposed model for the use of digital elements in educational game activities was applied to develop the game content. The development of the game called "Playing with Tweezers" was carried out in 3 phases and was evaluated by 15 participants, comprising students and professional experts in various areas of knowledge such as nursing, information technology, and education. An environment was created with an initial screen, menu buttons containing the rules of the game, and virtual tour modes for learning and assessment. The "digital" nursing student needs engagement, stimulation, reality, and entertainment, not just readings. "Playing with Tweezers" is an example of educational gaming as an innovative teaching strategy in nursing that encourages the strategy of involving the use of educational games to support theoretical or practical classroom teaching. Thus, the teacher does not work with only 1 type of teaching methodology, but with a combination of different methodologies. In addition, we cannot forget that skill training in an educational game does not

  16. Setting up home-based palliative care in countries with limited resources: a model from Sarawak, Malaysia.

    Science.gov (United States)

    Devi, B C R; Tang, T S; Corbex, M

    2008-12-01

    The provision of palliative care (PC) and opioids is difficult to ensure in remote areas in low- and middle-income countries. We describe here the set up of a home-care program in Sarawak (the Malaysian part of the Borneo Island), where half the population lives in villages that are difficult to access. The establishment of this program, initiated in 1994 by the Department of Radiotherapy of Sarawak General Hospital, consisted of training, empowering nurses, simplifying referral, facilitating access to medication, and increasing awareness among public and health professionals about PC. The program has been sustainable and cost efficient, serving 936 patients in 2006. The total morphine usage in the program increased from 1400 g in 2006. The results show that pain medication can be provided even in remote areas with effective organization and empowerment of nurses, who were the most important determinants for the set up of this program. Education of family was also a key aspect. The authors believe that the experience gained in Sarawak may help other regions with low or middle resources in the set up of their PC program especially for their remote rural population.

  17. Physical validation issue of the NEPTUNE two-phase modelling: validation plan to be adopted, experimental programs to be set up and associated instrumentation techniques developed

    International Nuclear Information System (INIS)

    Pierre Peturaud; Eric Hervieu

    2005-01-01

    Full text of publication follows: A long-term joint development program for the next generation of nuclear reactors simulation tools has been launched in 2001 by EDF (Electricite de France) and CEA (Commissariat a l'Energie Atomique). The NEPTUNE Project constitutes the Thermal-Hydraulics part of this comprehensive program. Along with the underway development of this new two-phase flow software platform, the physical validation of the involved modelling is a crucial issue, whatever the modelling scale is, and the present paper deals with this issue. After a brief recall about the NEPTUNE platform, the general validation strategy to be adopted is first of all clarified by means of three major features: (i) physical validation in close connection with the concerned industrial applications, (ii) involving (as far as possible) a two-step process successively focusing on dominant separate models and assessing the whole modelling capability, (iii) thanks to the use of relevant data with respect to the validation aims. Based on this general validation process, a four-step generic work approach has been defined; it includes: (i) a thorough analysis of the concerned industrial applications to identify the key physical phenomena involved and associated dominant basic models, (ii) an assessment of these models against the available validation pieces of information, to specify the additional validation needs and define dedicated validation plans, (iii) an inventory and assessment of existing validation data (with respect to the requirements specified in the previous task) to identify the actual needs for new validation data, (iv) the specification of the new experimental programs to be set up to provide the needed new data. This work approach has been applied to the NEPTUNE software, focusing on 8 high priority industrial applications, and it has resulted in the definition of (i) the validation plan and experimental programs to be set up for the open medium 3D modelling

  18. Fiber optic based OSL set up for online and offline measurements of dose due to ionizing radiation

    International Nuclear Information System (INIS)

    Rawat, N.S.; Kulkarni, M.S.; Upadhyay, B.N.; Srikanth, G.; Bindra, K.S.; Oak, S.M.

    2016-01-01

    An optic-fiber dosimetry system based on optically stimulated luminescence (OSL) and radio-luminescence (RL) from Al_2O_3 : C single-crystal (detector) was designed and developed. The set up is intended to measure dose and dose rates at various radiological installations. The Al_2O_3:C single crystal (from Landaeur Inc. USA) was coupled to a fiber optic delivery system and OSL from the detector is stimulated via the optical fiber cable using light from a Nd:YAG laser. OSL and RL signals are later used to predict cumulative dose and dose rates using "6"0Co gamma source. (author)

  19. Sensor set-up for wireless measurement of automotive rim and wheel parameters in laboratory conditions

    Science.gov (United States)

    Borecki, M.; Prus, P.; Korwin-Pawlowski, M. L.; Rychlik, A.; Kozubel, W.

    2017-08-01

    Modern rims and wheels are tested at the design and production stages. Tests can be performed in laboratory conditions and on the ride. In the laboratory, complex and costly equipment is used, as for example wheel balancers and impact testers. Modern wheel balancers are equipped with electronic and electro-mechanical units that enable touch-less measurement of dimensions, including precision measurement of radial and lateral wheel run-out, automatic positioning and application of the counterweights, and vehicle wheel set monitoring - tread wear, drift angles and run-out unbalance. Those tests are performed by on-wheel axis measurements with laser distance meters. The impact tester enables dropping of weights from a defined height onto a wheel. Test criteria are the loss of pressure of the tire and generation of cracks in the wheel without direct impact of the falling weights. In the present paper, a set up composed of three accelerometers, a temperature sensor and a pressure sensor is examined as the base of a wheel tester. The sensor set-up configuration, on-line diagnostic and signal transmission are discussed.

  20. The Impact of Institutional Settings on Learning Behavior by Venture Capitalists and Start-Ups

    DEFF Research Database (Denmark)

    Gatti, Anna; Vendelø, Morten Thanning

    2005-01-01

    differen-ces in local institutional settings affect learning and adaptation by European venture ca-pitalists and start-ups, and thus, affect the processes of field formation. For example, it has been observed that institutional settings can facilitate or discourage learning from direct experience (Herriot...... is to understand if and how US venture capitalism affect the evolvement of venture capitalism in Europe. We study the emergence of a venture capitalist industry in Denmark and Italy, and thus, by selecting two countries with distinctive differences in cultures and institutions, we study learning and adaptation...

  1. Rank the Voltage across Light Bulbs … Then Set up the Live Experiment

    Science.gov (United States)

    Jacobs, Greg C.

    2018-01-01

    The Tasks Inspired by Physics Education Research (TIPERS) workbooks pose questions in styles quite different from the end-of-chapter problems that those of us of a certain age were assigned back in the days before Netscape. My own spin on TIPERS is not just to do them on paper, but to have students set up the situations in the laboratory to…

  2. Application of activation methods on the Dubna experimental transmutation set-ups.

    Science.gov (United States)

    Stoulos, S; Fragopoulou, M; Adloff, J C; Debeauvais, M; Brandt, R; Westmeier, W; Krivopustov, M; Sosnin, A; Papastefanou, C; Zamani, M; Manolopoulou, M

    2003-02-01

    High spallation neutron fluxes were produced by irradiating massive heavy targets with proton beams in the GeV range. The experiments were performed at the Dubna High Energy Laboratory using the nuclotron accelerator. Two different experimental set-ups were used to produce neutron spectra convenient for transmutation of radioactive waste by (n,x) reactions. By a theoretical analysis neutron spectra can be reproduced from activation measurements. Thermal-epithermal and fast-super-fast neutron fluxes were estimated using the 197Au, 238U (n,gamma) and (n,2n) reactions, respectively. Depleted uranium transmutation rates were also studied in both experiments.

  3. Goal setting and action planning in the rehabilitation setting: development of a theoretically informed practice framework.

    Science.gov (United States)

    Scobbie, Lesley; Dixon, Diane; Wyke, Sally

    2011-05-01

    Setting and achieving goals is fundamental to rehabilitation practice but has been criticized for being a-theoretical and the key components of replicable goal-setting interventions are not well established. To describe the development of a theory-based goal setting practice framework for use in rehabilitation settings and to detail its component parts. Causal modelling was used to map theories of behaviour change onto the process of setting and achieving rehabilitation goals, and to suggest the mechanisms through which patient outcomes are likely to be affected. A multidisciplinary task group developed the causal model into a practice framework for use in rehabilitation settings through iterative discussion and implementation with six patients. Four components of a goal-setting and action-planning practice framework were identified: (i) goal negotiation, (ii) goal identification, (iii) planning, and (iv) appraisal and feedback. The variables hypothesized to effect change in patient outcomes were self-efficacy and action plan attainment. A theory-based goal setting practice framework for use in rehabilitation settings is described. The framework requires further development and systematic evaluation in a range of rehabilitation settings.

  4. Setting-up of a direct reading emission spectrometer and its adaptation for plutonium handling

    International Nuclear Information System (INIS)

    Page, A.G.; Godbole, S.V.; Kulkarni, M.J.; Porwal, N.K.; Thulasidas, S.K.; Sastry, M.D.; Srinivasan, P.S.

    1986-01-01

    A Jarrell-Ash 750 AtomComp 1100 series direct reading emission spectrometer was set up and its performance features were checked with regard to analysis of uranium-based samples using d.c. arc/inductively coupled argon plasma excitation techniques. The instrument has been subsequently modified to enable handling of plutonium-based samples. The modifications include building up of a specially designed glove-box around the excitation sources and consequent changes in the electro-mechanical controls associated with them. The modified system was extensively used for the trace metal assay of FBTR fuel sample. (author)

  5. Secondary electron images obtained with a standard photoelectron emission microscope set-up

    International Nuclear Information System (INIS)

    Benka, Oswald; Zeppenfeld, Peter

    2005-01-01

    The first results of secondary electron images excited by 3-4.3 keV electrons are presented. The images are obtained with a standard FOCUS-PEEM set-up equipped with an imaging energy filter (IEF). The electron gun was mounted on a standard PEEM entrance flange at an angle of 25 deg. with respect to the sample surface. A low extraction voltage of 500 V was used to minimize the deflection of the electron beam by the PEEM extraction electrode. The secondary electron images are compared to photoelectron images excited by a standard 4.9 eV UV lamp. In the case of a Cu pattern on a Si substrate it is found that the lateral resolution without the IEF is about the same for electron and photon excitation but that the relative electron emission intensities are very different. The use of the IEF reduces the lateral resolution. Images for secondary electron energies between eV 1 and eV 2 were obtained by setting the IEF to -V 1 and -V 2 ∼-(V 1 +5V) potentials and taking the difference of both images. Images up to 100 eV electron energies were recorded. The material contrast obtained in these difference images is discussed in terms of a secondary electron and photoelectron emission model and secondary electron energy spectra measured with a LEED-Auger spectrometer

  6. Setting-up a small observatory from concept to construction

    CERN Document Server

    Arditti, David

    2008-01-01

    Every amateur astronomer who is considering a purpose-built observatory will find this book absolutely invaluable during both the planning and the construction stages. Drawing on David Arditti’s practical experience and that of many other amateur astronomers, it gives invaluable help in making all the important decisions. To begin with, Setting up a Small Observatory addresses what you really need from an observatory, whether to build or buy, what designs you should consider, and where you should site it. Uniquely, it also considers the aesthetics of an amateur observatory: how to make it fit in with your home, garden, and yard, even disguising it as a more common garden building if necessary. There’s also a wealth of practical details for constructing and equipping your small observatory – everything from satisfying local planning laws and building codes through to making sure that your completed observatory is well-equipped, convenient, and comfortable to use. Whether you are considering a simple low-...

  7. Set up for simultaneous water desalination and power generation

    International Nuclear Information System (INIS)

    Hasan, S.W.; Mookhi, M.B.; Sadiq, M.A.; Hasan, Z.; Zaidi, S.I.; Shah, W.A.

    2010-01-01

    Instead of following the conventional fuel oriented power generation methods and dissipating its heat into environment, we evaporate saline water into steam and use its energy to generate power. Using this scheme would make sea water usable in power generation which at the moment is only being used for cooling purposes in the power plants. The steam used for generating electricity is eventually collected, condensed and used for potable purposes. The proposed scheme may be seen as Steam Power Generation with additional feature of desalination. We set up an experimental test bed in order to calculate the electric power available using this scheme. To ensure safety for human consumption, we also perform chemical tests on the desalinated water to see whether it is fit to be used for drinking and agricultural purposes. Our conclusions are based on actual experiments and laboratory tests; procedures outlined here may be used at larger scale for more in-depth analyses. We also highlight future extensions and modifications in this work. (author)

  8. ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings

    NARCIS (Netherlands)

    Drachsler, Hendrik; Pecceu, Dries; Arts, Tanja; Hutten, Edwin; Rutledge, Lloyd; Van Rosmalen, Peter; Hummel, Hans; Koper, Rob

    2009-01-01

    Drachsler, H., Peccau, D., Arts, T., Hutten, E., Rutledge, L., Van Rosmalen, P., Hummel, H. G. K., & Koper, R. (2009). ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings. Presentation at the 2nd Workshop Mash-Up Personal Learning

  9. Cyclotron produced radionuclides: Guidelines for setting up a facility

    International Nuclear Information System (INIS)

    2009-01-01

    Establishment of a cyclotron based radionuclide and radiopharmaceutical production facility is a major undertaking regardless of the scope and size of the facility. Regulatory demands of radiation protection and pharmaceutical manufacturing only add to the need for meticulous attention to a large number of factors in overall planning and successful implementation. Also, a significant commitment of resources, not just during the onset of the project, but also for sustained continuity further adds to the already difficult decision making process. In this publication, all these issues have been addressed and discussed conceptually for the benefit of planners and stakeholders of a new facility. The need for a clear vision and realistic scope of the programme has been repeatedly emphasized throughout this book as this aspect of project planning is absolutely vital for defining and achieving the mission and objectives of the facility. The most critical aspects in conceptualization, planning and subsequent implementation have been discussed in detail and are highlighted below as necessary actions: - Performing a feasibility study which balances wishful thinking with project viability; - Forming a task force composed of the stakeholders to evaluate strategically the various aspects of project planning to ultimately recommend the scope and objectives of the facility, and also to formulate the project plan; - Assessing the financial aspects of the project, including the set-up and operating costs of the facility through the development of business models and cost-benefit analyses; - Designing a facility and layout that encompasses the scope of the project and also takes into consideration the regulatory requirements; - Ensuring the availability of appropriately qualified and trained staff, critical for efficient and high quality operation of the facility; - Applying GMP regulations for the production of radiopharmaceutical products which are consistently safe for human use

  10. The Influence of Natural Frequency of the Experimental Set-up on the Friction Coefficient of Stainless Steel-304

    OpenAIRE

    M. A. Chowdhury; Md. M. Helali

    2010-01-01

    The present paper investigates experimentally the effect of natural frequency of the experimental set-up on friction property of stainless steel-304. To do so, a pin-on-disc apparatus having facility of vibrating the test samples at different directions, amplitudes and frequencies was designed and fabricated. The natural frequency of the set-up was varied by adding dead loads of the setup from 0 kg to 50 kg. At each added load the friction coefficient has been measured. Results show that both...

  11. Equipment line-up developed for structuring programmed digital systems important to safety

    International Nuclear Information System (INIS)

    Remus, L.; Colling, J.M.; Buisson, J.

    1986-01-01

    The use of the programmed digital techniques in systems important to safety led to developing equipment line-ups which allow to procedure, through using a restricted number of sub-assemblies, a variety of facilities capable of performing diversified functions. Upon remembering the requirements that such equipment are required to meet (quality assurance both at the design and production stages, qualification, testing opportunities, etc.) the equipments produced by MERLIN GERIN are described in this paper. Such equipments include a whole set of printed circuit boards, plug-in units with self-engaging connectors and the related cabinets to accomodate them. The following systems are made up of such equipments: Digital integrated protection system; Rod control and monitoring system; Reactor power distribution monitoring equipment. This equipment line-up has been gradually complemented and is still further expanding both as a result of the component further development or for the purpose of meeting new requirements or applications (new digital neutron instrumentation, local area networks). Experience gained thus far provides us with the capability of working out in a short time programmed systems for further applications in the nuclear power field

  12. Setting up of a PIXE facility at FOTIA at BARC

    International Nuclear Information System (INIS)

    Joseph, Daisy; Saxena, A.

    2005-01-01

    PIXE-(Proton Induced X-ray Emission) -an ideal technique for material characterization has been set up at the Folded Tandem Ion Accelerator (FOTIA) at BARC, Trombay. A separate beam line at 45 deg port in which a dedicated PIXE chamber has been installed is being used for PIXE studies. PIXE studies on gold standards were carried out using protons of energy 3.3 MeV. Caritage values of gold standards were obtained which agree well with the certified values. Single element standard solutions (100 μg/ml) for low-Z elements such as Cr, Mn, Fe, Co, Cu and Zn were analyzed by PIXE. Well resolved α and β components of the x-rays were seen with detection limits in the range of 0.8-4 μg/g. (author)

  13. Test plan for Digface Chemical and Radiation Assay System

    International Nuclear Information System (INIS)

    Akers, D.W.

    1993-07-01

    The Digface Chemical and Radiation Assay System (CRAS) Project will develop a sensor using Prompt Gamma Neutron Activation Analysis (PGNAA) that can detect the present of hazardous chemicals and radioactive materials. The CRAS is being designed for in situ assay of closed drums and contaminated soils for gamma-ray emitting radionuclides and hazardous elements. The CRAS is based upon the use of 252 Cf PGNAA with a germanium gamma-ray spectrometer as the analyzer. Tasks being performed include determining detection limits for a number of hazardous chemicals and assessing matrix and transmission effects through soil. Initial analyses suggest that the technique is applicable to a number of hazardous materials such as trichloroethane and carbon tetrachloride

  14. Community Exchange Systems. What They Are. How They Work. How to Set One Up.

    Science.gov (United States)

    Page, Leslie

    This booklet explains the concept of a community exchange system (CES), or barter system, for the exchange of goods and services and describes how to set one up. The booklet is concerned only with nonprofit, voluntary organizations. The booklet is organized in four sections. The first section introduces the community exchange systems idea and…

  15. Research on mechanical and sensoric set-up for high strain rate testing of high performance fibers

    Science.gov (United States)

    Unger, R.; Schegner, P.; Nocke, A.; Cherif, C.

    2017-10-01

    Within this research project, the tensile behavior of high performance fibers, such as carbon fibers, is investigated under high velocity loads. This contribution (paper) focuses on the clamp set-up of two testing machines. Based on a kinematic model, weight optimized clamps are designed and evaluated. By analyzing the complex dynamic behavior of conventional high velocity testing machines, it has been shown that the impact typically exhibits an elastic characteristic. This leads to barely predictable breaking speeds and will not work at higher speeds when acceleration force exceeds material specifications. Therefore, a plastic impact behavior has to be achieved, even at lower testing speeds. This type of impact behavior at lower speeds can be realized by means of some minor test set-up adaptions.

  16. Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy

    International Nuclear Information System (INIS)

    Moore, C J; Marchant, T E; Amer, A M

    2006-01-01

    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergy TM linear accelerator produced an unattenuated beam for a central 'target zone' and a partially attenuated beam for an outer 'set-up zone'. Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error

  17. Developing and setting up optical methods to study the speckle patterns created by optical beam smoothing

    International Nuclear Information System (INIS)

    Surville, J.

    2005-12-01

    We have developed three main optical methods to study the speckles generated by a smoothed laser source. The first method addresses the measurement of the temporal and spatial correlation functions of the source, with a modified Michelson interferometer. The second one is a pump-probe technique created to shoot a picture of a speckle pattern generated at a set time. And the third one is an evolution of the second method dedicated to time-frequency coding, thanks to a frequency chirped probe pulse. Thus, the speckles can be followed in time and their motion can be described. According to these three methods, the average size and duration of the speckles can be measured. It is also possible to measure the size and the duration of each of them and mostly their velocity in a given direction. All the results obtained have been confronted to the different existing theories. We show that the statistical distributions of the measured speckles'size and speckles'intensity agree satisfactorily with theoretical values

  18. Runs 800, 813, 842 and physics runs from 18.1.77 to 21.5.77, Development of a new set-up for working line measurements including a Fast Fourier Transform Spectrum Analyser and using weak beam excitiation with broad-band noise

    CERN Document Server

    Borer, J

    1977-01-01

    Runs 800, 813, 842 and physics runs from 18.1.77 to 21.5.77, Development of a new set-up for working line measurements including a Fast Fourier Transform Spectrum Analyser and using weak beam excitiation with broad-band noise

  19. Setting up Information Literacy Workshops in School Libraries: Imperatives, Principles and Methods

    Directory of Open Access Journals (Sweden)

    Reza Mokhtarpour

    2010-09-01

    Full Text Available While many professional literature have talked at length about the importance of dealing with information literacy in school libraries in ICT dominated era, but few have dealt with the nature and mode of implementation nor offered a road map. The strategy emphasized in this paper is to hold information literacy sessions through effective workshops. While explaining the reasons behind such workshops being essential in enhancing information literacy skills, the most important principles and stages for setting up of such workshops are offered in a step-by-step manner.

  20. Test of a cryogenic set-up for a 10 meter long liquid nitrogen cooled superconducting power cable

    DEFF Research Database (Denmark)

    Træholt, Chresten; Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa

    2000-01-01

    High temperature superconducting power cables may be cooled by a forced flow of sub-cooled liquid nitrogen. One way to do this is to circulate the liquid nitrogen (LN2) by means of a mechanical pump through the core of the cable and through a sub-cooler.Besides the cooling station, the cryogenics...... cable. We report on our experimental set-up for testing a 10 meter long high temperature superconducting cable with a critical current of 3.2 kA at 77K. The set-up consists of a custom designed cable end termination, current lead, coolant feed-through, liquid nitrogen closed loop circulation system...

  1. An Overview of Strategic Utilization Plan for the Moroccan Nuclear Research Reactor over the Period of 2010–2015

    International Nuclear Information System (INIS)

    Jibre, A.; Boufraqech, A.

    2013-01-01

    The National Centre for Nuclear Energy, Science and Technology (CNESTEN), a Moroccan state-owned company, is setting up a strategic utilization plan for its recently commissioned and licensed nuclear research reactor, Triga Mark II, 2 MW, over the period of 2010–2015. This strategic plan is aiming to efficiently and effectively meet existing and potential needs: research and development, education and training, and generally all related products and services, both at national and regional level, within a sustainable framework. For that purpose, CNESTEN’s vision is to develop and strengthen its position in the market place by fully integrating both operational and logistical issues in being strategically led, market oriented, competitively focused, operationally efficient, revenue generating applications emphasized, and human resources driven. In terms of existing and potential services and products to be delivered from the research reactor, CNESTEN is more focusing on education and training, for which an international training centre is under development; radioisotopes production, for both medical and industrial uses for which CNESTEN has a leading national position; analytical techniques such as NAA and PGNAA; neutron beam techniques such as neutron imaging and neutron diffraction; and irradiation services for NTD. (author)

  2. How To Set Up Your Own Small Business. Service Company Case Study. Manufacturing Firm Case Study. Retail Store Case Study.

    Science.gov (United States)

    Fallek, Max

    This collection of case studies is intended for use in a course in setting up a small business. The first, a case study of the process of setting up a service company, covers analyzing the pros and cons of starting one's own business, assessing the competition and local market, and selecting a site for and financing the business. The principal…

  3. Improved mortar set-up technique

    CSIR Research Space (South Africa)

    De Villiers, D

    2010-05-01

    Full Text Available -up Technique Presented at the Mortar Systems Conference By D de Villiers May 2009 Mobile Mortars Slide 2 © CSIR 2008 www.csir.co.za Mobile Mortars Slide 3 © CSIR 2008 www.csir.co.za Mobile Mortars Slide 4... © CSIR 2008 www.csir.co.za Mortar Tests Slide 5 © CSIR 2008 www.csir.co.za Mortar Tests Slide 6 © CSIR 2008 www.csir.co.za Electronic Sensors Slide 7 © CSIR 2008...

  4. Test set up description and performances for HAWAII-2RG detector characterization at ESTEC

    Science.gov (United States)

    Crouzet, P.-E.; ter Haar, J.; de Wit, F.; Beaufort, T.; Butler, B.; Smit, H.; van der Luijt, C.; Martin, D.

    2012-07-01

    In the frame work of the European Space Agency's Cosmic Vision program, the Euclid mission has the objective to map the geometry of the Dark Universe. Galaxies and clusters of galaxies will be observed in the visible and near-infrared wavelengths by an imaging and spectroscopic channel. For the Near Infrared Spectrometer instrument (NISP), the state-of-the-art HAWAII-2RG detectors will be used, associated with the SIDECAR ASIC readout electronic which will perform the image frame acquisitions. To characterize and validate the performance of these detectors, a test bench has been designed, tested and validated. This publication describes the pre-tests performed to build the set up dedicated to dark current measurements and tests requiring reasonably uniform light levels (such as for conversion gain measurements). Successful cryogenic and vacuum tests on commercial LEDs and photodiodes are shown. An optimized feed through in stainless steel with a V-groove to pot the flex cable connecting the SIDECAR ASIC to the room temperature board (JADE2) has been designed and tested. The test set up for quantum efficiency measurements consisting of a lamp, a monochromator, an integrating sphere and set of cold filters, and which is currently under construction will ensure a uniform illumination across the detector with variations lower than 2%. A dedicated spot projector for intra-pixel measurements has been designed and built to reach a spot diameter of 5 μm at 920nm with 2nm of bandwidth [1].

  5. Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis.

    Science.gov (United States)

    Bonanzinga, Tommaso; Signorelli, Cecilia; Bontempi, Marco; Russo, Alessandro; Zaffagnini, Stefano; Marcacci, Maurilio; Bragonzoni, Laura

    2016-01-01

    dinamic roentgen stereophotogrammetric analysis (RSA), a technique currently based only on customized radiographic equipment, has been shown to be a very accurate method for detecting three-dimensional (3D) joint motion. The aim of the present work was to evaluate the applicability of an innovative RSA set-up for in vivo knee kinematic analysis, using a biplane fluoroscopic image system. To this end, the Authors describe the set-up as well as a possible protocol for clinical knee joint evaluation. The accuracy of the kinematic measurements is assessed. the Authors evaluated the accuracy of 3D kinematic analysis of the knee in a new RSA set-up, based on a commercial biplane fluoroscopy system integrated into the clinical environment. The study was organized in three main phases: an in vitro test under static conditions, an in vitro test under dynamic conditions reproducing a flexion-extension range of motion (ROM), and an in vivo analysis of the flexion-extension ROM. For each test, the following were calculated, as an indication of the tracking accuracy: mean, minimum, maximum values and standard deviation of the error of rigid body fitting. in terms of rigid body fitting, in vivo test errors were found to be 0.10±0.05 mm. Phantom tests in static and kinematic conditions showed precision levels, for translations and rotations, of below 0.1 mm/0.2° and below 0.5 mm/0.3° respectively for all directions. the results of this study suggest that kinematic RSA can be successfully performed using a standard clinical biplane fluoroscopy system for the acquisition of slow movements of the lower limb. a kinematic RSA set-up using a clinical biplane fluoroscopy system is potentially applicable and provides a useful method for obtaining better characterization of joint biomechanics.

  6. Developing Pokemon AI For Finding Comfortable Settings

    OpenAIRE

    Panumate, Chetprayoon; Iida, Hiroyuki

    2016-01-01

    This paper explores an innovative way to find a comfortable setting of video games. Pokemon is chosen as benchmark and game refinement measure is employed for the assessment. The number of Pokemon that one trainer can carry (i.e., setting with n=6) has never been changed after the first episode of Pokemon was released in 1996. Pokemon battle is simulated and various AIs are developed for the experiments. The results show that the original setting is the best for many players of various levels.

  7. Characterisation of the epithermal neutron irradiation facility at the Portuguese research reactor using MCNP.

    Science.gov (United States)

    Beasley, D G; Fernandes, A C; Santos, J P; Ramos, A R; Marques, J G; King, A

    2015-05-01

    The radiation field at the epithermal beamline and irradiation chamber installed at the Portuguese Research Reactor (RPI) at the Campus Tecnológico e Nuclear of Instituto Superior Técnico was characterised in the context of Prompt Gamma Neutron Activation Analysis (PGNAA) applications. Radiographic films, activation foils and thermoluminescence dosimeters were used to measure the neutron fluence and photon dose rates in the irradiation chamber. A fixed-source MCNPX model of the beamline and chamber was developed and compared to measurements in the first step towards planning a new irradiation chamber. The high photon background from the reactor results in the saturation of the detector and the current facility configuration yields an intrinsic insensitivity to various elements of interest for PGNAA. These will be addressed in future developments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Testing normative and self-appraisal feedback in an online slot-machine pop-up in a real-world setting

    Directory of Open Access Journals (Sweden)

    Michael Mario Auer

    2015-03-01

    Full Text Available Over the last few years, there have been an increasing number of gaming operators that have incorporated on-screen pop-up messages while gamblers play on slot machines and/or online as one of a range of tools to help encourage responsible gambling. Coupled with this, there has also been an increase in empirical research into whether such pop-up messages are effective, particularly in laboratory settings. However, very few studies have been conducted on the utility of pop-up messages in real-world gambling settings. The present study investigated the effects of normative and self-appraisal feedback in a slot machine pop-up message compared to a simple (non-enhanced pop-up message. The study was conducted in a real-world gambling environment by comparing the behavioural tracking data of two representative random samples of 800,000 gambling sessions (i.e., 1.6 million sessions in total across two conditions (i.e., simple pop-up message versus an enhanced pop-up message. The results indicated that the additional normative and self-appraisal content doubled the number of gamblers who stopped playing after they received the enhanced pop-up message (1.39% compared to the simple pop-up message (0.67%. The data suggest that pop-up messages influence only a small number of gamblers to cease long playing sessions and that enhanced messages are slightly more effective in helping gamblers to stop playing in-session.

  9. Set up of Uranium-Molybdenum powder production (HMD process)

    International Nuclear Information System (INIS)

    Lopez, Marisol; Pasqualini, Enrique E.; Gonzalez, Alfredo G.

    2003-01-01

    Powder metallurgy offers different alternatives for the production of Uranium-Molybdenum (UMo) alloy powder in sizes smaller than 150 microns. This powder is intended to be used as a dispersion fuel in an aluminum matrix for research, testing and radioisotopes production reactors (MTR). A particular process of massive hydriding the UMo alloy in gamma phase has been developed. This work describes the final adjustments of process variables to obtain UMo powder by hydriding-milling-de hydriding (HMD) and its capability for industrial scaling up. (author)

  10. Ebola 2014: Setting up a port health screening programme at an international train station.

    Science.gov (United States)

    Cleary, Vivien; Wynne-Evans, Edward; Freed, James; Fleet, Katie; Thorn, Simone; Turbitt, Deborah

    2017-12-01

    An outbreak of Ebola virus disease (EVD) began in Guinea in December 2013 and was declared a Public Health Emergency of International Concern by the World Health Organization in August 2014. In October, the UK government tasked Public Health England (PHE) to set up EVD screening at key ports. The key aim of port-of-entry screening was to identify passengers coming from areas with high risk of EVD, and give them advice to raise their awareness of symptoms and what actions to take. Direct flights from Sierra Leone, Guinea or Liberia had all been cancelled, so intelligence on passenger numbers and routes was used to identify the most commonly used routes from the affected countries into the UK. One of these was St Pancras International train station. Screening had never previously been implemented at a UK train station so had to be set up from scratch. Key to the success of this was excellent multi-agency working between PHE, the UK Border Force, Eurostar, Network Rail and the Cabinet Office. This paper gives an overview of the activation of EVD screening at St Pancras International and the subsequent decommissioning.

  11. Royal Order of 12 December 1975 setting up a National Energy Committee

    International Nuclear Information System (INIS)

    1978-01-01

    The National Energy Committee was set up by Royal Order of 12 December 1975. Its duties are to advise on the general objectives of energy policy and its implementation. It supervises execution of the policy and makes recommendations on matters within its competence. The Committee is chaired by the Minister for Economic Affairs and Energy and is composed of representatives of the Government, trade unions, undertakings, consumers, gas and electricity committees, oil and coal industries and a delegate of the Planning Department. This Order repeals the Order of 17 July 1957 creating an Energy Advisory Council. (NEA) [fr

  12. Iterated greedy algorithms to minimize the total family flow time for job-shop scheduling with job families and sequence-dependent set-ups

    Science.gov (United States)

    Kim, Ji-Su; Park, Jung-Hyeon; Lee, Dong-Ho

    2017-10-01

    This study addresses a variant of job-shop scheduling in which jobs are grouped into job families, but they are processed individually. The problem can be found in various industrial systems, especially in reprocessing shops of remanufacturing systems. If the reprocessing shop is a job-shop type and has the component-matching requirements, it can be regarded as a job shop with job families since the components of a product constitute a job family. In particular, sequence-dependent set-ups in which set-up time depends on the job just completed and the next job to be processed are also considered. The objective is to minimize the total family flow time, i.e. the maximum among the completion times of the jobs within a job family. A mixed-integer programming model is developed and two iterated greedy algorithms with different local search methods are proposed. Computational experiments were conducted on modified benchmark instances and the results are reported.

  13. Decree No. 89-85 of 8 February 1989 setting up a Council on Technological Risk Prevention

    International Nuclear Information System (INIS)

    1989-01-01

    The Council set up by this Decree contributes to the assessment of collective risks arising from industrial activities, in particular nuclear activities, through its opinions, recommendations, studies, and proposes the relevant preventive actions to the Government. (NEA) [fr

  14. A conceptual design of the set-up for solid state spectroscopy with free electron laser and insertion device radiation

    CERN Document Server

    Makhov, V N

    2001-01-01

    The set-up for complex solid state spectroscopy with the use of enhanced properties of radiation from insertion devices and free electron lasers is proposed. Very high flux and pulsed properties of radiation from insertion devices and free electron lasers offer the possibility for the use of such powerful techniques as electron paramagnetic resonance (EPR) and optically detected magnetic resonance (ODMR) for the studies of excited states of electronic excitations or defects in solids. The power density of radiation can become high enough for one more method of exited-state spectroscopy: transient optical absorption spectroscopy. The set-up is supposed to combine the EPR/ODMR spectrometer, i.e. cryostat supplied with superconducting magnet and microwave system, and the optical channels for excitation (by radiation from insertion devices or free electron laser) and detection of luminescence (i.e. primary and secondary monochromators). The set-up can be used both for 'conventional' spectroscopy of solids (reflec...

  15. Integration of micro milling highspeed spindle on a microEDM-milling machine set-up

    DEFF Research Database (Denmark)

    De Grave, Arnaud; Hansen, Hans Nørgaard; Andolfatto, Loic

    2009-01-01

    In order to cope with repositioning errors and to combine the fast removal rate of micro milling with the precision and small feature size achievable with micro EDM milling, a hybrid micro-milling and micro-EDM milling centre was built and tested. The aim was to build an affordable set-up, easy...... by micro milling. Examples of test parts are shown and used as an experimental validation....

  16. The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

    International Nuclear Information System (INIS)

    Barbos, D.; Paunoiu, C.; Mladin, M.; Cosma, C.

    2008-01-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φ scd = 1.10 6 n/cm 2 /s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates

  17. Set-up and first operation of a plasma oven for treatment of low level radioactive wastes

    Directory of Open Access Journals (Sweden)

    Nachtrodt Frederik

    2014-01-01

    Full Text Available An experimental device for plasma treatment of low and intermediate level radioactive waste was built and tested in several design variations. The laboratory device is designed with the intention to study the general effects and difficulties in a plasma incineration set-up for the further future development of a larger scale pilot plant. The key part of the device consists of a novel microwave plasma torch driven by 200 W electric power, and operating at atmospheric pressure. It is a specific design characteristic of the torch that a high peak temperature can be reached with a low power input compared to other plasma torches. Experiments have been carried out to analyze the effect of the plasma on materials typical for operational low-level wastes. In some preliminary cold tests the behavior of stable volatile species e. g., caesium was investigated by TXRF measurements of material collected from the oven walls and the filtered off-gas. The results help in improving and scaling up the existing design and in understanding the effects for a pilot plant, especially for the off-gas collection and treatment.

  18. Production and characterization of protonated molecular clusters containing a given number of water molecules with the DIAM set-up

    International Nuclear Information System (INIS)

    Bruny, G.

    2010-01-01

    nano-scale characterization of irradiation in bio-molecular systems requires observation of novel features which are now achievable with the recent technical progress. This work is a central part in the development of DIAM which is a new experimental set-up devoted to irradiation of bio-molecular clusters at the Institut de Physique Nucleaire de Lyon. The development of the cluster source and of a double focusing mass spectrometer leads to the production of intense beams of mass selected protonated molecular clusters. Combined with this mass selected cluster beams an innovative detection technique is demonstrated in collision induced dissociation experiments. The results contribute to the knowledge of the stability and the structure of the small protonated water clusters and mixed clusters of water and pyridine. (author)

  19. Keeping Up: Personal Staff Development

    Science.gov (United States)

    Woolls, Blanche

    2009-01-01

    Some essential components of "keeping current" with trends and new developments in the school library field for library media specialists includes attending conferences and reading professional literature. Beginning in May 2007, one article on "keeping up" each year has been devoted to summarizing the major themes in conferences and professional…

  20. The Use of Instructional and Motivational Self-Talk in Setting up a Physical Education Lesson

    Science.gov (United States)

    Zourbanos, Nikos

    2013-01-01

    The main purpose of this article is to provide guidelines to physical educators for setting up a self-talk program during their lesson. The article briefly presents definitions of self-talk and research findings in sport and physical education to highlight the important benefits of positive self-talk in enhancing task performance. It also provides…

  1. Set up of a method for the adjustment of resonance parameters on integral experiments

    International Nuclear Information System (INIS)

    Blaise, P.

    1996-01-01

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.)

  2. Quantitative and qualitative applications of the neutron-gamma borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Aylmer, J.A.; Eisler, P.L.; Borsaru, M.

    1989-01-01

    Two neutron-γ borehole logging applications are described. In a quantitative application of the prompt-gamma neutron-activation analysis (PGNAA) technique, research was carried out both in the laboratory and at a mine to establish a suitable borehole logging technology for manganese-grade predictions. As an example of the qualitative application of PGNAA, the use of this method has been demonstrated for the determination of lithology. (author)

  3. Quantitative and qualitative applications of the neutron-gamma borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Eisler, P.L.; Borsaru, M.; Aylmer, J.A.

    1990-01-01

    Two examples of neutron-gamma borehole logging application are described. In the quantitative application of the PGNAA technique, research was carried out both in the laboratory and at a mine to establish a suitable borehole logging technology for Mn-grade predictions. As an example of qualitative application of PGNAA, use of this method has been demonstrated for determination of lithology. (author). 4 refs, 10 figs, 7 tabs

  4. Institutions of Catching-up Development (On the Project of a New Model for Economic Development of Russia

    Directory of Open Access Journals (Sweden)

    Viktor Meerovich Polterovich

    2016-11-01

    Full Text Available The article shows that institutional trajectories of catching-up development in successful countries including similar interim institutions; this similarity is explained by common technological, institutional and cultural limitations which need to be taken into account and overcome. Corporatism, indicative planning, the availability of the “general” development agency with broad mandate, undervalued exchange rate – these and some other mechanisms provide the countries of the “economic miracle” with an opportunity to initiate and maintain rapid economic growth despite the low level of human capital, underdeveloped civic culture and market failures. Institutions of catching-up development contributed to the formation of collaborative relations between the government, business and society. They eased the limitations and were gradually modified, providing a transition to modern democracies with efficient market economy. The conducted analysis helps outline a plan for an institutional reform taking into account Russia’s institutional features. The principles of administrative reform are considered. The author also sets the objective of forming a “hybrid” system of national planning which includes indicative planning and program budgeting. A combination of public-private partnership and program financing is proposed for the financing of the planned projects. The author proposes to use Japanese experience of promoting temporary association of companies for the development of modernization projects. The principles of reforming the systems of state property and science management are discussed

  5. Prompt gamma neutron activation analysis facility at the RA-6 research reactor

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Calzetta, O

    2004-01-01

    A prompt gamma neutron activation activation analysis facility was developed at the 500 kw thermal power RA-6 research reactor of the Bariloche Atomic Center, Argentina.This facility consist of a radial beam port with external positioning of the sample.The gamma radiation is reduced by a bismuth filter placed inside the extraction tube and the beam diameter is limited by a set of two collimators up to 5 cm.The neutron flux at the sample position is 7 10 6 n/cm 2 s with a Cadmium ratio of 20/1.The gamma detector is a 50 % efficiency type p HPGe rounded by a NaI(Tl) for Compton suppressioning.The gamma spectra is measured through 0 to 8.5 MeV.The background have counting rate of 350 cps without sample. In this work is shown the efficiency curve, the calculed sensibilities and the lower detection limits for B, Cd, Sm, Gd, H, Cl, Hg, Eu, Ti, Ag, Au, Mo. The RA-6's PGNAA facility is fully working, although the analytic capacity is under improvement [es

  6. Specific heat measurement set-up for quench condensed thin superconducting films.

    Science.gov (United States)

    Poran, Shachaf; Molina-Ruiz, Manel; Gérardin, Anne; Frydman, Aviad; Bourgeois, Olivier

    2014-05-01

    We present a set-up designed for the measurement of specific heat of very thin or ultra-thin quench condensed superconducting films. In an ultra-high vacuum chamber, materials of interest can be thermally evaporated directly on a silicon membrane regulated in temperature from 1.4 K to 10 K. On this membrane, a heater and a thermometer are lithographically fabricated, allowing the measurement of heat capacity of the quench condensed layers. This apparatus permits the simultaneous thermal and electrical characterization of successively deposited layers in situ without exposing the deposited materials to room temperature or atmospheric conditions, both being irreversibly harmful to the samples. This system can be used to study specific heat signatures of phase transitions through the superconductor to insulator transition of quench condensed films.

  7. Diagnosis and outcome of birth asphyxia in resource constrained health care set up

    International Nuclear Information System (INIS)

    Zaman, S.; Shah, S.A.; Mehmood, S.; Shahzad, S.; Munir, M.; Mushtaq, A.

    2017-01-01

    Objective: To determine morbidity and mortality of neonates with low APGAR score in a resource constrained health care set up. Study Design: Prospective descriptive study. Place and Duration of Study: The study was carried out in combined military hospital Attock, from Jan 2013 to Jan 2015. Material and Methods: All term neonates with 37 completed weeks of gestation and APGAR score less than 7 were included in the study. APGAR score was calculated by an attending pediatrician, gynecologist or trained female nurse at 0 and 5 minutes. In Neonatal Intensive Care Unit [NICU] the babies were daily examined by pediatrician. Outcome was documented in term of morbidity i.e. fits and mortality i.e. death of babies. Results: Total number of neonates included in the study were 85 of which 55 (65%) were males and 30 (35%) were females. Of the total neonates 65 (76%) were discharged in satisfactory conditions and 20 (24%) expired during stay in the hospital. The mean APGAR score of newborns was 4.98 +- 0.98 at 5 minutes. During stay in hospital 46 (54%) were diagnosed to have hypoxic ischemic encephalopathy 2 (HIE2), those diagnosed with HIE3 were 5 (6%) and the rest 14 (16%) with HIE1. Conclusion: Low APGAR score is an important cause of admission to NICU. Low APGAR score was found associated with increased risk of fits in neonates and one of the most important cause of mortality in our set up. (author)

  8. Combining in situ characterization methods in one set-up: looking with more eyes into the intricate chemistry of the synthesis and working of heterogeneous catalysts.

    Science.gov (United States)

    Bentrup, Ursula

    2010-12-01

    Several in situ techniques are known which allow investigations of catalysts and catalytic reactions under real reaction conditions using different spectroscopic and X-ray methods. In recent years, specific set-ups have been established which combine two or more in situ methods in order to get a more detailed understanding of catalytic systems. This tutorial review will give a summary of currently available set-ups equipped with multiple techniques for in situ catalyst characterization, catalyst preparation, and reaction monitoring. Besides experimental and technical aspects of method coupling including X-ray techniques, spectroscopic methods (Raman, UV-vis, FTIR), and magnetic resonance spectroscopies (NMR, EPR), essential results will be presented to demonstrate the added value of multitechnique in situ approaches. A special section is focussed on selected examples of use which show new developments and application fields.

  9. Setting development goals using stochastic dynamical system models.

    Science.gov (United States)

    Ranganathan, Shyam; Nicolis, Stamatios C; Bali Swain, Ranjula; Sumpter, David J T

    2017-01-01

    The Millennium Development Goals (MDG) programme was an ambitious attempt to encourage a globalised solution to important but often-overlooked development problems. The programme led to wide-ranging development but it has also been criticised for unrealistic and arbitrary targets. In this paper, we show how country-specific development targets can be set using stochastic, dynamical system models built from historical data. In particular, we show that the MDG target of two-thirds reduction of child mortality from 1990 levels was infeasible for most countries, especially in sub-Saharan Africa. At the same time, the MDG targets were not ambitious enough for fast-developing countries such as Brazil and China. We suggest that model-based setting of country-specific targets is essential for the success of global development programmes such as the Sustainable Development Goals (SDG). This approach should provide clear, quantifiable targets for policymakers.

  10. Setting up a clinical trial for a novel disease: a case study of the Doxycycline for the Treatment of Nodding Syndrome Trial - challenges, enablers and lessons learned.

    Science.gov (United States)

    Anguzu, Ronald; Akun, Pamela R; Ogwang, Rodney; Shour, Abdul Rahman; Sekibira, Rogers; Ningwa, Albert; Nakamya, Phellister; Abbo, Catherine; Mwaka, Amos D; Opar, Bernard; Idro, Richard

    2018-01-01

    A large amount of preparation goes into setting up trials. Different challenges and lessons are experienced. Our trial, testing a treatment for nodding syndrome, an acquired neurological disorder of unknown cause affecting thousands of children in Eastern Africa, provides a unique case study. As part of a study to determine the aetiology, understand pathogenesis and develop specific treatment, we set up a clinical trial in a remote district hospital in Uganda. This paper describes our experiences and documents supportive structures (enablers), challenges faced and lessons learned during set-up of the trial. Protocol development started in September 2015 with phased recruitment of a critical study team. The team spent 12 months preparing trial documents, procurement and training on procedures. Potential recruitment sites were pre-visited, and district and local leaders met as key stakeholders. Key enablers were supportive local leadership and investment by the district and Ministry of Health. The main challenges were community fears about nodding syndrome, adverse experiences of the community during previous research and political involvement. Other challenges included the number and delays in protocol approvals and lengthy procurement processes. This hard-to-reach area has frequent power and Internet fluctuations, which may affect cold chains for study samples, communication and data management. These concerns decreased with a pilot community engagement programme. Experiences and lessons learnt can reduce the duration of processes involved in trial-site set-up. A programme of community engagement and local leader involvement may be key to the success of a trial and in reducing community opposition towards participation in research.

  11. Scale up risk of developing oil shale processing units

    International Nuclear Information System (INIS)

    Oepik, I.

    1991-01-01

    The experiences in oil shale processing in three large countries, China, the U.S.A. and the U.S.S.R. have demonstrated, that the relative scale up risk of developing oil shale processing units is related to the scale up factor. On the background of large programmes for developing the oil shale industry branch, i.e. the $30 billion investments in colorado and Utah or 50 million t/year oil shale processing in Estonia and Leningrad Region planned in the late seventies, the absolute scope of the scale up risk of developing single retorting plants, seems to be justified. But under the conditions of low crude oil prices, when the large-scale development of oil shale processing industry is stopped, the absolute scope of the scale up risk is to be divided between a small number of units. Therefore, it is reasonable to build the new commercial oil shale processing plants with a minimum scale up risk. For example, in Estonia a new oil shale processing plant with gas combustion retorts projected to start in the early nineties will be equipped with four units of 1500 t/day enriched oil shale throughput each, designed with scale up factor M=1.5 and with a minimum scale up risk, only r=2.5-4.5%. The oil shale retorting unit for the PAMA plant in Israel [1] is planned to develop in three steps, also with minimum scale up risk: feasibility studies in Colorado with Israel's shale at Paraho 250 t/day retort and other tests, demonstration retort of 700 t/day and M=2.8 in Israel, and commercial retorts in the early nineties with the capacity of about 1000 t/day with M=1.4. The scale up risk of the PAMA project r=2-4% is approximately the same as that in Estonia. the knowledge of the scope of the scale up risk of developing oil shale processing retorts assists on the calculation of production costs in erecting new units. (author). 9 refs., 2 tabs

  12. The application of a low-cost 3D depth camera for patient set-up and respiratory motion management in radiotherapy

    Science.gov (United States)

    Tahavori, Fatemeh

    Respiratory motion induces uncertainty in External Beam Radiotherapy (EBRT), which can result in sub-optimal dose delivery to the target tissue and unwanted dose to normal tissue. The conventional approach to managing patient respiratory motion for EBRT within the area of abdominal-thoracic cancer is through the use of internal radiological imaging methods (e.g. Megavoltage imaging or Cone-Beam Computed Tomography) or via surrogate estimates of tumour position using external markers placed on the patient chest. This latter method uses tracking with video-based techniques, and relies on an assumed correlation or mathematical model, between the external surrogate signal and the internal target position. The marker's trajectory can be used in both respiratory gating techniques and real-time tracking methods. Internal radiological imaging methods bring with them limited temporal resolution, and additional radiation burden, which can be addressed by external marker-based methods that carry no such issues. Moreover, by including multiple external markers and placing them closer to the internal target organs, the effciency of correlation algorithms can be increased. However, the quality of such external monitoring methods is underpinned by the performance of the associated correlation model. Therefore, several new approaches to correlation modelling have been developed as part of this thesis and compared using publicly-available datasets. Highly competitive results have been obtained when compared against state-of-the-art methods. Marker-based methods also have the disadvantages of requiring manual set-up time for marker placement and patient positioning and potential issues with reproducibility of marker placement. This motivates the investigation of non-contact marker-free methods for use in EBRT, which is the main topic of this thesis. The Microsoft Kinect is used as an example of a low-cost consumer grade 3D depth camera for capturing and analysing external

  13. SETTING UP OF A HOMECARE SYSTEM FOR HIGH COST NEBULISERS IN A PAEDIATRIC CYSTIC FIBROSIS CENTRE.

    Science.gov (United States)

    Chorro-Mari, Veronica; Christiansen, Nanna

    2016-09-01

    informed in writing about the changes in commissioning and planned repatriation of HCN. This information was also included on discharge prescriptions for patients on any of the HCNs as part of the pharmacy screening process.A system for follow up prescriptions as repeat was set up between the team so we would not have unexpected urgent requests and we could avoid missed doses, urgent delivery charge or stress in the team. In order to manage the prescriptions and ease communication across the team a database was developed. From March to July 2014 (16 weeks) one hundred and four patients were successfully repatriated to tertiary care. A planned method and agreed standard operation procedure was key to effectively capture and repatriate all patients while at the same time keeping the increase on workload for the pharmacy team to a minimum. The fact of having a strong pharmacy presence as part of the multidisciplinary team attending CF clinics and ward rounds was vital in making this work. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Effectiveness of Goal-Setting Telephone Follow-Up on Health Behaviors of Patients with Ischemic Stroke: A Randomized Controlled Trial.

    Science.gov (United States)

    Wan, Li-Hong; Zhang, Xiao-Pei; Mo, Miao-Miao; Xiong, Xiao-Ni; Ou, Cui-Ling; You, Li-Ming; Chen, Shao-Xian; Zhang, Min

    2016-09-01

    Adopting healthy behaviors is critical for secondary stroke prevention, but many patients fail to follow national guidelines regarding diet, exercise, and abstinence from risk factors. Compliance often decreases with time after hospital discharge, yet few studies have examined programs promoting long-term adherence to health behaviors. Goal setting and telephone follow-up have been proven to be effective in other areas of medicine, so this study evaluated the effectiveness of a guideline-based, goal-setting telephone follow-up program for patients with ischemic stroke. This was a multicenter, assessor-blinded, parallel-group, randomized controlled trial. Ninety-one stroke patients were randomized to either a control group or an intervention group. Intervention consisted of predischarge education and 3 goal-setting follow-up sessions conducted by phone. Data were collected at baseline and during the third and sixth months after hospital discharge. Six months after discharge, patients in the intervention group exhibited significantly higher medication adherence than patients in the control group. There were no statistically significant differences in physical activity, nutrition, low-salt diet adherence, blood pressure monitoring, smoking abstinence, unhealthy use of alcohol, and modified Rankin Scale (mRS) scores between the 2 groups. Goal-setting telephone follow-up intervention for ischemic stroke patients is feasible and leads to improved medication adherence. However, the lack of group differences in other health behavior subcategories and in themRS score indicates a need for more effective intervention strategies to help patients reach guideline-recommended targets. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  15. Residual rotational set-up errors after daily cone-beam CT image guided radiotherapy of locally advanced cervical cancer

    International Nuclear Information System (INIS)

    Laursen, Louise Vagner; Elstrøm, Ulrik Vindelev; Vestergaard, Anne; Muren, Ludvig P.; Petersen, Jørgen Baltzer; Lindegaard, Jacob Christian; Grau, Cai; Tanderup, Kari

    2012-01-01

    Purpose: Due to the often quite extended treatment fields in cervical cancer radiotherapy, uncorrected rotational set-up errors result in a potential risk of target miss. This study reports on the residual rotational set-up error after using daily cone beam computed tomography (CBCT) to position cervical cancer patients for radiotherapy treatment. Methods and materials: Twenty-five patients with locally advanced cervical cancer had daily CBCT scans (650 CBCTs in total) prior to treatment delivery. We retrospectively analyzed the translational shifts made in the clinic prior to each treatment fraction as well as the residual rotational errors remaining after translational correction. Results: The CBCT-guided couch movement resulted in a mean translational 3D vector correction of 7.4 mm. Residual rotational error resulted in a target shift exceeding 5 mm in 57 of the 650 treatment fractions. Three patients alone accounted for 30 of these fractions. Nine patients had no shifts exceeding 5 mm and 13 patients had 5 or less treatment fractions with such shifts. Conclusion: Twenty-two of the 25 patients have none or few treatment fractions with target shifts larger than 5 mm due to residual rotational error. However, three patients display a significant number of shifts suggesting a more systematic set-up error.

  16. A Monte Carlo calculation of the pionium break-up probability with different sets of pionium target cross sections

    International Nuclear Information System (INIS)

    Santamarina, C; Schumann, M; Afanasyev, L G; Heim, T

    2003-01-01

    Chiral perturbation theory predicts the lifetime of pionium, a hydrogen-like π + π - atom, to better than 3% precision. The goal of the DIRAC experiment at CERN is to obtain and check this value experimentally by measuring the break-up probability of pionium in a target. In order to accurately measure the lifetime one needs to know the relationship between the break-up probability and the lifetime to 1% accuracy. We have obtained this dependence by modelling the evolution of pionic atoms in the target using Monte Carlo methods. The model relies on the computation of the pionium-target-atom interaction cross sections. Three different sets of pionium-target cross sections with varying degrees of complexity were used: from the simplest first-order Born approximation involving only the electrostatic interaction to a more advanced approach, taking into account multiphoton exchanges and relativistic effects. We conclude that, in order to obtain the pionium lifetime to 1% accuracy from the break-up probability, the pionium-target cross sections must be known with the same accuracy for the low excited bound states of the pionic atom. This result has been achieved, for low Z targets, with the two most precise cross section sets. For large Z targets only the set accounting for multiphoton exchange satisfies the condition

  17. Setting clear expectations for safety basis development

    International Nuclear Information System (INIS)

    MORENO, M.R.

    2003-01-01

    DOE-RL has set clear expectations for a cost-effective approach for achieving compliance with the Nuclear Safety Management requirements (10 CFR 830, Nuclear Safety Rule) which will ensure long-term benefit to Hanford. To facilitate implementation of these expectations, tools were developed to streamline and standardize safety analysis and safety document development resulting in a shorter and more predictable DOE approval cycle. A Hanford Safety Analysis and Risk Assessment Handbook (SARAH) was issued to standardized methodologies for development of safety analyses. A Microsoft Excel spreadsheet (RADIDOSE) was issued for the evaluation of radiological consequences for accident scenarios often postulated for Hanford. A standard Site Documented Safety Analysis (DSA) detailing the safety management programs was issued for use as a means of compliance with a majority of 3009 Standard chapters. An in-process review was developed between DOE and the Contractor to facilitate DOE approval and provide early course correction. As a result of setting expectations and providing safety analysis tools, the four Hanford Site waste management nuclear facilities were able to integrate into one Master Waste Management Documented Safety Analysis (WM-DSA)

  18. Concept and set-up of an IR-gas sensor construction kit

    Science.gov (United States)

    Sieber, Ingo; Perner, Gernot; Gengenbach, Ulrich

    2015-10-01

    The paper presents an approach to a cost-efficient modularly built non-dispersive optical IR-gas sensor (NDIR) based on a construction kit. The modularity of the approach offers several advantages: First of all it allows for an adaptation of the performance of the gas sensor to individual specifications by choosing the suitable modular components. The sensitivity of the sensor e.g. can be altered by selecting a source which emits a favorable wavelength spectrum with respect to the absorption spectrum of the gas to be measured or by tuning the measuring distance (ray path inside the medium to be measured). Furthermore the developed approach is very well suited to be used in teaching. Together with students a construction kit on basis of an optical free space system was developed and partly implemented to be further used as a teaching and training aid for bachelor and master students at our institute. The components of the construction kit are interchangeable and freely fixable on a base plate. The components are classified into five groups: sources, reflectors, detectors, gas feed, and analysis cell. Source, detector, and the positions of the components are fundamental to experiment and test different configurations and beam paths. The reflectors are implemented by an aluminum coated adhesive foil, mounted onto a support structure fabricated by additive manufacturing. This approach allows derivation of the reflecting surface geometry from the optical design tool and generating the 3D-printing files by applying related design rules. The rapid fabrication process and the adjustment of the modules on the base plate allow rapid, almost LEGO®-like, experimental assessment of design ideas. Subject of this paper is modeling, design, and optimization of the reflective optical components, as well as of the optical subsystem. The realization of a sample set-up used as a teaching aid and the optical measurement of the beam path in comparison to the simulation results are

  19. A National Regulatory Authority set up in a developing country: case of Mali

    International Nuclear Information System (INIS)

    Kone, Nagantie

    2008-01-01

    Full text: The Republic of Mali is member of the International Atomic Energy Agency since 1961. Of since the creation of the IAEA, some African countries are members. The technical cooperation with the Agency started in the years 1975. Through that cooperation, many pacific uses of nuclear techniques have been introduced, then developed at different levels in many socio- economic domains as medicine, agriculture, research, and so on. That development of nuclear techniques use has occurred without legislation at all or in some limited cases with part of the legislation of the colonizing country), in a precise field (like radiography in medicine). Later the need of regulatory infrastructure implementation started. That implementation has followed several ways in the different African countries. Also, it started earlier in countries which had advanced activities in nuclear techniques and very later in others. Most if not all of these infrastructure (say regulatory board) were created by the greatest users of the nuclear techniques, the Ministry of Health in most cases or Energy Commission for Countries having a research reactor. After the years 90, the Agency has developed new vision in the implementation of Regulatory Authorities. The new innovation was: 1-) Development of Regulatory Authority with independent statute (decisions and finance); 2-) Assuming post graduate training in developing countries to come other the lack of human resources. That new strategy of the IAEA has facilitated the apparition and development of several new regulatory authorities. We are going to develop here the progress done by one of these new regulatory authorities, through five years being. (author)

  20. Setting up a new CZO in the Ganga basin: instrumentation, stakeholder engagement and preliminary observations

    Science.gov (United States)

    Gupta, S.; Tripathi, S.; Sinha, R.; Karumanchi, S. H.; Paul, D.; Tripathi, S. N.; Sen, I. S.; Dash, S. K.

    2017-12-01

    The Ganga plains represent the abode of more than 400 million people and a region of severe anthropogenic disturbance to natural processes. Changing agricultural practices, inefficient use of water, contamination of groundwater systems, and decrease in soil fertility are some of the issues that have affected the long-term resilience of hydrological processes. The quantification of these processes demands a network of hydro-meteorological instrumentation, low-cost sensors, continuous engagement of stakeholders and real time data transmission at a fine interval. We have therefore set up a Critical Zone Observatory (CZO) in a small watershed (35km2) that forms an intensively managed rural landscape consisting of 92% of agricultural land in the Pandu River Basin (a small tributary of the Ganga River). Apart from setting up a hydro-meteorological observatory, the major science questions we want to address relate to development of water balance model, understanding the soil-water interaction and estimation of nutrient fluxes in the watershed. This observatory currently has various types of sensors that are divided into three categories: (a) spatially not dense but temporally fine data, (b) spatially dense but temporally not fine data and(c) spatially dense and temporally fine data. The first category represent high-cost sensors namely automatic weather stations that are deployed at two locations and provide data at 15-minute interval. The second category includes portable soil moisture, discharge and groundwater level at weekly/ biweekly interval. The third category comprises low-cost sensors including automatic surface and groundwater level sensors installed on open wells to monitor the continuous fluctuation of water level at every 15 minutes. In addition to involving the local communities in data collection (e.g. manual rainfall measurement, water and soil sampling), this CZO also aims to provide relevant information to them for improving their sustainability. The

  1. Setting up and running an advanced light microscopy and imaging facility.

    Science.gov (United States)

    Sánchez, Carlos; Muñoz, Ma Ángeles; Villalba, Maite; Labrador, Verónica; Díez-Guerra, F Javier

    2011-07-01

    During the last twenty years, interest in light microscopy and imaging techniques has grown in various fields, such as molecular and cellular biology, developmental biology, and neurobiology. In addition, the number of scientific articles and journals using these techniques is rapidly increasing. Nowadays, most research institutions require sophisticated microscopy systems to cover their investigation demands. In general, such instruments are too expensive and complex to be purchased and managed by a single laboratory or research group, so they have to be shared with other groups and supervised by specialized personnel. This is the reason why microscopy and imaging facilities are becoming so important at research institutions nowadays. In this unit, we have gathered and presented a number of issues and considerations from our own experience that we hope will be helpful when planning or setting up a new facility.

  2. ECONOMIC EVALUATION OF A BREEDING PROGRAMME FOR SETTING UP TWO HIGH PERFORMANCES BEE LINES

    OpenAIRE

    POPESCU, A.; RADOI, C.

    2003-01-01

    This study aimed to evaluate costs, incomes and financial results related to the creation of two Apis Mellifica Carpatica lines, based on a specific Breeding Programme within a closed population. The two beelines have been carefully selected for the bee populations living in two areas of Romania: North Moldavia and South Muntenia. A new selection technology is set up in order to produce high performance queen bees, well adapted to the environmental conditions mainly to picking. Genetic gain w...

  3. Toward a Common Ontology of Scaling Up in Development

    Directory of Open Access Journals (Sweden)

    April N. Frake

    2018-03-01

    Full Text Available Scaling up development measures to target global food insecurity has a distinctly spatial character and is often cited as a solution to the global hunger crisis. Development does not occur without scaling and consensus on the ontological meaning of scaling up is a vital component to developing sustainable solutions to the global hunger crisis across geographical scales. Yet ‘scaling up’, while frequently used throughout Research and Development (R&D and Natural Resource Management (NRM literature, lacks ontological agreement. We begin by considering the noun, ‘scale’ and existing literature on scaling up, then present a visual analysis of definitions provided for scaling up across development institutions. Our study finds that the organization of terms used across these definitions falls into three distinct categories: Interventions, Mechanisms, and Outcomes. Further, we contend that the continued uncertainty is linked to scale being applied in two fashions: as a noun (outcome and verb (process. Rather than calling for reformed definitions, we argue for precision of definitions. To that end, we present a conceptual framework of scaling up that gives greater emphasis on separating the noun scale, from the verb, to scale. Further, Monitoring and Evaluation (M&E in our model complements scaling efforts beginning with how scaling up is defined by program, through to final evaluation of success.

  4. 12 November 1991-Ministerial Order setting up a Commission for assessing information in the nuclear field

    International Nuclear Information System (INIS)

    1991-01-01

    The Commission sets up by this Order must ensure that the public is kept informed on the technical, health, ecological, economic and financial aspects of nuclear energy, and advises the Secretary of State for Energy on the conditions for informing the public and proposes methods for disseminating such information. (NEA)

  5. Order of 24 April 1970 on the setting up of ionizing radiation electric generators for medical purposes

    International Nuclear Information System (INIS)

    1970-01-01

    This Order prescribes that the setting up of electric generators emitting ionizing radiations with an energy higher than 500 KeV used for medical purposes are subject to licensing and provides a model applications form to this effect. (NEA) [fr

  6. Feasibility for the setting up of a multipurpose food irradiation facility in Senegal

    International Nuclear Information System (INIS)

    Diop, Y.; Marchioni, E.; Hasswlmann, C.; Ba, D.; Kuntz, F.

    2002-01-01

    The setting up of a cobalt-60 (activity 500 kCi) irradiation facility in the highest populated region of Senegal (Dakar district) to treat a wide range of foodstuffs for local consumption (millet/sorghum, rice, maize, cowpeas, potatoes, onions, mangoes, citrus fruits and dried fishes) is considered as profitable for a private investor or a Senegalese food producer (or trader), provided the tonnage of foodstuffs treated is adequate, more than 22,000 t·kGy, i.e. a total tonnage above 77,000 t, taking into account the irradiation doses used for the various foodstuffs. (author)

  7. FTIR free-jet set-up for the high resolution spectroscopic investigation of condensable species

    Science.gov (United States)

    Georges, R.; Bonnamy, A.; Benidar, A.; Decroi, M.; Boissoles, J.

    2002-05-01

    An existing experimental set-up combining Fourier transform infrared (FTIR) spectroscopy and free-jet cooling has been modified significantly to allow high resolution studies of the spectrum of monomer species which are liquid under standard conditions. Evaporation of the liquid samples is controlled by a condenser apparatus which is described. A supersonic planar expansion issuing from a narrow aperture is preferred for its very high cooling rate. Such an expansion, probed with a pitot tube, has a zone of limited temperature gradient close to the nozzle exit. The continuum isentropic model appears well suited to describing the thermodynamic properties of the flow up to a high number of nozzle diameters downstream. High resolution spectra of benzene and methanol have been recorded in the 3 µm wavelength range, and their analysis demonstrates a well defined rotational temperature in the 20-25 K range.

  8. Development of a Communication Strategy to Increase Interprofessional Collaboration in the Outpatient Setting

    Directory of Open Access Journals (Sweden)

    Chelsea Phillips Renfro

    2018-01-01

    Full Text Available Managing patient health is a complex task, requiring the support of an interprofessional healthcare team. Collaboration between neighboring community pharmacies and primary care practices can be an alternate solution for team-based patient care. The purpose of this project was to design and implement a communication strategy for patients with diabetes and hypertension between a community pharmacy and physician practice. An interprofessional team for the practice settings was formed to develop a strategy for collaboration. After agreeing on the common goals and target patient population for the disease states, the team devised a way to communicate via electronic health record (EHR. The communication strategy allowed for more frequent follow-up with the patients which has the potential to result in better clinical outcomes. A communication strategy between a community pharmacy and a physician practice office can be achieved using EHR technology. The greatest outcome of this project was the formation of the collaborative team between the practice settings that continues to work together on additional patient-centered initiatives. Further research is warranted to allow for incorporation of patient perspectives in development of communication strategies.

  9. Worms Eat My Garbage. How To Set Up and Maintain a Worm Composting System. First Edition.

    Science.gov (United States)

    Appelhof, Mary

    This book is a resource for parents and teachers who want to teach about recycling and composting by setting up and maintaining a worm composting system. It is designed to be a detailed yet simple manual of vermicomposting. The manual covers the basics of vermicomposting and answers such questions as where to store a composting container, what…

  10. Results of performance tests on chemical and radiation measurement systems for use at a dig-face

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Lawrence, R.S.; Pawelko, R.J.

    1995-04-01

    Chemical and radiation measurement systems are being developed for use at a dig-face to provide sensing capability during the excavation of previously buried waste. it is believed that on-line dig-face characterization will reduce environmental, health, and safety risks during the cleanup of buried waste sites as well as improve the efficiency of the cleanup process. This report describes progress in the development of three measurement systems: (a) a γ/neutron monitor that scans the dig-face for high levels of radiation prior to excavation, (b) a Ge spectrometer that identifies specific radionuclides located with the γ/neutron monitor, and (c) a prompt γ neutron activation analysis (PGNAA) system that measures the presence of chlorine and chlorinated compounds often associated with hazardous waste. The Ge spectrometer and PGNAA system also will provide off-line but on-site capability of radionuclide and elemental identification of excavated waste prior to handling, treatment, transportation, or disposal

  11. Calculation And Design Of A New Configuration For Radiation Shielding At Neutron Beam No.3 For Fundamental And Applied Researches

    International Nuclear Information System (INIS)

    Vuong Huu Tan; Tran Tuan Anh; Nguyen Kien Cuong; Nguyen Canh Hai; Nguyen Xuan Hai; Pham Ngoc Son; Ho Huu Thang

    2011-01-01

    The tangential horizontal channel of No. 3 of the Dalat Research Reactor has been opened and used during the 1990s. The utilizations of the thermal neutron beam at this channel were the Neutron Radiography and the Prompt Gamma Neutron Activation Analysis method (PGNAA). At present, the neutron beam used for nuclear structure data researches based on the Summing of Amplitude Coincident Pulses system (SACP). Beside, several related research equipments have been set up and operated for the research purposes. A renovation of the neutron channel, therefore, will play an important role in safe and effective utilizations of the neutron beam in fields of nuclear physic training and researches. A new configuration for radiation shielding has been simulated by MCNP code. The calculated results of dose rates for neutron and gamma at working positions are in range of dose rate limit. (author)

  12. MARKETING STRATEGY FOR SETTING UP AN OWN COFFEE SHOP IN CHINA : Using Starbucks as a case study

    OpenAIRE

    Wei , ChiJiao

    2016-01-01

    The thesis aimed to find out a suitable marketing strategy and making a marketing plan for setting up an own coffee shop in Shanghai, China. Coffee was one of the most popular drinks in the world and coffee has been accepted by more and more Chinese people. Coffee industry was well-received choice for the entrepreneurs to start up their own business in China. Marketing strategy played an important role in the intense market competition. A successful marketing strategy could help the coffee co...

  13. Development of the patient setting system for BNCT at JRR-4

    International Nuclear Information System (INIS)

    Kumada, H.; Yamamoto, K.; Torii, Y.

    2000-01-01

    A new treatment planning software: Computational Dosimetry System (JCDS) is in progress its development for BNCT with epithermal neutron beam in JAERI. Irradiation conditions such as beam angle to a patient are calculated by JCDS. In order to implement these conditions, it is necessary to precisely set the patient to actual irradiation position simulated by JCDS beforehand. Therefore, the Patient Setting System, which accurately and quickly sets the patient to the irradiation position, is being developed with JCDS concurrently. In this report, the current status of the development of JCDS and the Patient Setting System in JAERI will be described. (author)

  14. 29 July 1991-Royal Order setting up a Higher Institute for Emergency Planning

    International Nuclear Information System (INIS)

    1991-01-01

    This Institute was set up in accordance with national legislation on protection against major industrial risks and Directive 89/618 Euratom on informing the general public about health protection measures to be applied and steps to be taken in the event of a radiological emergency. The Institute's duties include: organizing training for emergency planning and assistance; promoting the exchange of ideas on emergency planning between the authorities and operators of installations which could generate major risks, including nuclear installations; and disseminating adequate and regularly updated information to persons involved in emergency assistance on the risks they incur and the protection measures to be taken. (NEA)

  15. INTELLECT DEVELOPMENT IN THE GROWING-UP PROCESS

    Directory of Open Access Journals (Sweden)

    E. M. Revenko

    2014-01-01

    Full Text Available The research is aimed at studying the dynamics specificity of intelligence development in the growing-up process.The research methods involve the group intelligence tests for junior teens; R. Amthauer’s students test (IST adapted by L. A. Yasyukova; longitude and cross-section methods.The research findings demonstrate both the irregularity and conformity of intelligence development starting from the secondary school and up to the undergraduate university level. In the secondary school, there is a fast growth of quantitative characteristics of intellectual dynamics and verbal skills do minance. However in the high school, the qualitative competence-related changes prevail giving way to the non-verbal skills; and the given trend continues up to the undergraduate level.The author emphasizes the differences in intellect dynamics depending on the student’s basic mental faculties: the school students with higher faculties demonstrate a higher intelligence dynamics, while the university students reveal quite the opposite trend of lower intelligence dynamics in groups with higher faculties. As a result, the obvious differences in students’ intellect capacities in the secondary and high school become less evident at the university level.The author points out the novelty of differentiated analysis of intellectual indices dynamics, substantiating the assumption of individual typical patterns of intellect development.The research outcomes make a foundation for the theory of individual and typological options (trajectories of intellect development, and guarantee a differentiated approach to students’ education according to the rate and tempo specifics of intellectual maturity.

  16. Three axis vector magnet set-up for cryogenic scanning probe microscopy

    International Nuclear Information System (INIS)

    Galvis, J. A.; Herrera, E.; Buendía, A.; Guillamón, I.; Vieira, S.; Suderow, H.; Azpeitia, J.; Luccas, R. F.; Munuera, C.; García-Hernandez, M.

    2015-01-01

    We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi 2 Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert

  17. Three axis vector magnet set-up for cryogenic scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Galvis, J. A. [Laboratorio de Bajas Temperaturas, Departamento de Física de la Materia Condensada, Instituto de Ciencia de Materiales Nicolás Cabrera, Condensed Matter Physics Center (IFIMAC), Facultad de Ciencias Universidad Autónoma de Madrid, 28049 Madrid (Spain); Departamento de Ciencias Naturales Facultad de Ingeniería Universidad Central, Bogotá (Colombia); Herrera, E.; Buendía, A. [Laboratorio de Bajas Temperaturas, Departamento de Física de la Materia Condensada, Instituto de Ciencia de Materiales Nicolás Cabrera, Condensed Matter Physics Center (IFIMAC), Facultad de Ciencias Universidad Autónoma de Madrid, 28049 Madrid (Spain); Guillamón, I.; Vieira, S.; Suderow, H. [Laboratorio de Bajas Temperaturas, Departamento de Física de la Materia Condensada, Instituto de Ciencia de Materiales Nicolás Cabrera, Condensed Matter Physics Center (IFIMAC), Facultad de Ciencias Universidad Autónoma de Madrid, 28049 Madrid (Spain); Unidad Asociada de Bajas Temperaturas y Altos Campos Magnéticos, UAM, CSIC, Cantoblanco, E-28049 Madrid (Spain); Azpeitia, J.; Luccas, R. F.; Munuera, C.; García-Hernandez, M. [Unidad Asociada de Bajas Temperaturas y Altos Campos Magnéticos, UAM, CSIC, Cantoblanco, E-28049 Madrid (Spain); Instituto de Ciencia de Materiales de Madrid, Consejo Superior de Investigaciones Científicas (ICMM-CSIC), Sor Juana Inés de la Cruz 3, 28049 Madrid (Spain); and others

    2015-01-15

    We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi{sub 2}Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert.

  18. Developing a Data-Set for Stereopsis

    Directory of Open Access Journals (Sweden)

    D.W Hunter

    2014-08-01

    Full Text Available Current research on binocular stereopsis in humans and non-human primates has been limited by a lack of available data-sets. Current data-sets fall into two categories; stereo-image sets with vergence but no ranging information (Hibbard, 2008, Vision Research, 48(12, 1427-1439 or combinations of depth information with binocular images and video taken from cameras in fixed fronto-parallel configurations exhibiting neither vergence or focus effects (Hirschmuller & Scharstein, 2007, IEEE Conf. Computer Vision and Pattern Recognition. The techniques for generating depth information are also imperfect. Depth information is normally inaccurate or simply missing near edges and on partially occluded surfaces. For many areas of vision research these are the most interesting parts of the image (Goutcher, Hunter, Hibbard, 2013, i-Perception, 4(7, 484; Scarfe & Hibbard, 2013, Vision Research. Using state-of-the-art open-source ray-tracing software (PBRT as a back-end, our intention is to release a set of tools that will allow researchers in this field to generate artificial binocular stereoscopic data-sets. Although not as realistic as photographs, computer generated images have significant advantages in terms of control over the final output and ground-truth information about scene depth is easily calculated at all points in the scene, even partially occluded areas. While individual researchers have been developing similar stimuli by hand for many decades, we hope that our software will greatly reduce the time and difficulty of creating naturalistic binocular stimuli. Our intension in making this presentation is to elicit feedback from the vision community about what sort of features would be desirable in such software.

  19. Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Erridge, Sara C.; Seppenwoolde, Yvette; Muller, Sara H.; Herk, Marcel van; Jaeger, Katrien de; Belderbos, Jose S.A.; Boersma, Liesbeth J.; Lebesque, Joos V.

    2003-01-01

    Purpose: To investigate patient set-up, tumor movement and shrinkage during 3D conformal radiotherapy for non-small cell lung cancer. Materials and methods: In 97 patients, electronic portal images (EPIs) were acquired and corrected for set-up using an off-line correction protocol based on a shrinking action level. For 25 selected patients, the orthogonal EPIs (taken at random points in the breathing cycle) throughout the 6-7 week course of treatment were assessed to establish the tumor position in each image using both an overlay and a delineation technique. The range of movement in each direction was calculated. The position of the tumor in the digitally reconstructed radiograph (DRR) was compared to the average position of the lesion in the EPIs. In addition, tumor shrinkage was assessed. Results: The mean overall set-up errors after correction were 0, 0.6 and 0.2 mm in the x (left-right), y (cranial-caudal) and z (anterior-posterior) directions, respectively. After correction, the standard deviations (SDs) of systematic errors were 1.4, 1.5 and 1.3 mm and the SDs of random errors were 2.9, 3.1 and 2.0 mm in the x-, y- and z-directions, respectively. Without correction, 41% of patients had a set-up error of more than 5 mm vector length, but with the set-up correction protocol this percentage was reduced to 1%. The mean amplitude of tumor motion was 7.3 (SD 2.7), 12.5 (SD 7.3) and 9.4 mm (SD 5.2) in the x-, y- and z-directions, respectively. Tumor motion was greatest in the y-direction and in particular for lower lobe tumors. In 40% of the patients, the projected area of the tumor regressed by more than 20% during treatment in at least one projection. In 16 patients it was possible to define the position of the center of the tumor in the DRR. There was a mean difference of 6 mm vector length between the tumor position in the DRR and the average position in the portal images. Conclusions: The application of the correction protocol resulted in a significant

  20. The Influence of Natural Frequency of the Experimental Set-up on the Friction Coefficient of Stainless Steel-304

    Directory of Open Access Journals (Sweden)

    M. A. Chowdhury

    2010-03-01

    Full Text Available The present paper investigates experimentally the effect of natural frequency of the experimental set-up on friction property of stainless steel-304. To do so, a pin-on-disc apparatus having facility of vibrating the test samples at different directions, amplitudes and frequencies was designed and fabricated. The natural frequency of the set-up was varied by adding dead loads of the setup from 0 kg to 50 kg. At each added load the friction coefficient has been measured. Results show that both the natural frequency and friction coefficient decrease with the increase of added loads. It has been also observed that the coefficient of friction increases with the increase of natural frequency of the experimental setup. The experimental results are also compared with those available in literature and simple physical explanations are provided.

  1. PENERAPAN METODE TUTOR SEBAYA UNTUK MENINGKATKAN KETERAMPILANPREPARE DANTABLE SET UP DALAM MATA KULIAH TATA HIDANG

    Directory of Open Access Journals (Sweden)

    Wahyuningsih Wahyuningsih

    2011-02-01

    Full Text Available This learning teching research was intended to improve the learning outcomes of the students practicing in the subject of prepare and table set up, the main subject of Tata Hidang I (Servicing Arragements I. The subject for this research consisted of 18 S1 students of the learning group number 02 for the study Program for PKK, concentrating on Tata Boga, Departement of Service & Production Technology, the Technical Faculty of Semarang State University for the academic period of 2009-2010. This research was conducted in the gasal semester of the academic year of 2009-2010. The needed data were collected by means of tests and obsevation on the learning outcomes of the students practicing in the sub-subject of Prepare and Table Set up. The data collection used grading sheets for practices in Tata Hidang as its instrument. The data were then analized using the method of descriptive presentation. This was a classroom-action research planned in three cycles. The second and third cycles were implemented based on reflections on the first cycle and on improvements that should be reached. Every cycle consisted of two face to face encounters and of 4 activities: (1planning, (2 implementations, (3 observations, (4 reflections. The results of this research showed that the use of peeer tutorials for the learning-teching pocesses had positive effects both on the students and the lecturers that it might improve the quality of lecturing for the Tata Hidang I. The grades obtained by the students from practicing in the sub-subject of prepare and table set up increased from the lowest grade C (46.7% BC and B (60% and AB (26.6 %, and AB (26.6%.. Trough the three cycles, the number of BC grade decreased from 66% to only 20%. Based on the results of this research, it is recommended that peer tutorial for the subject of Tata Hidang I and Servicing in Food & Beverage should be continued in order that the educational serveices provided to the practicing students might be

  2. Increased amino acids levels and the risk of developing of hypertriglyceridemia in a 7-year follow-up

    OpenAIRE

    Mook-Kanamori, D. O.; Römisch-Margl, W.; Kastenmüller, G.; Prehn, C.; Petersen, A. K.; Illig, T.; Gieger, C.; Wang-Sattler, R.; Meisinger, C.; Peters, A.; Adamski, J.; Suhre, K.

    2014-01-01

    Background Recently, five branched-chain and aromatic amino acids were shown to be associated with the risk of developing type 2 diabetes (T2D). Aim We set out to examine whether amino acids are also associated with the development of hypertriglyceridemia. Materials and methods We determined the serum amino acids concentrations of 1,125 individuals of the KORA S4 baseline study, for which follow-up data were available also at the KORA F4 7 years later. After exclusion for hypertriglyceridemia...

  3. The Roles of Feature-Specific Task Set and Bottom-Up Salience in Attentional Capture: An ERP Study

    Science.gov (United States)

    Eimer, Martin; Kiss, Monika; Press, Clare; Sauter, Disa

    2009-01-01

    We investigated the roles of top-down task set and bottom-up stimulus salience for feature-specific attentional capture. Spatially nonpredictive cues preceded search arrays that included a color-defined target. For target-color singleton cues, behavioral spatial cueing effects were accompanied by cue-induced N2pc components, indicative of…

  4. ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings

    NARCIS (Netherlands)

    Drachsler, Hendrik; Pecceu, Dries; Arts, Tanja; Hutten, Edwin; Rutledge, Lloyd; Van Rosmalen, Peter; Hummel, Hans; Koper, Rob

    2009-01-01

    Drachsler, H., Peccau, D., Arts, T., Hutten, E., Rutledge, L., Van Rosmalen, P., Hummel, H. G. K., & Koper, R. (2009). ReMashed – Recommendation Approaches for Mash-Up Personal Learning Environments in Formal and Informal Learning Settings. In F. Wild, M. Kalz, M. Palmér & D. Müller (Eds.),

  5. From simple vegetation surveys to management of biodiversity data. Problems in setting up a database for alpine flora

    Directory of Open Access Journals (Sweden)

    SPIEGELBERGER, Thomas

    2011-03-01

    Full Text Available This study discusses the establishment of the FlorEM database for alpine flora which intends to become a reference on plant diversity. The difficulties in setting up the database, its advantages and limitations are all presented here.

  6. Radiotherapy for breast cancer: respiratory and set-up uncertainties; Irradiation du cancer du sein: incertitudes liees aux mouvements respiratoires et au repositionnement

    Energy Technology Data Exchange (ETDEWEB)

    Saliou, M.G.; Giraud, P.; Simon, L.; Fournier-Bidoz, N.; Fourquet, A.; Dendale, R.; Rosenwald, J.C.; Cosset, J.M. [Institut Curie, Dept. d' Oncologie-Radiotherapie, 75 - Paris (France)

    2005-11-15

    Adjuvant Radiotherapy has been shown to significantly reduce locoregional recurrence but this advantage is associated with increased cardiovascular and pulmonary morbidities. All uncertainties inherent to conformal radiation therapy must be identified in order to increase the precision of treatment; misestimation of these uncertainties increases the potential risk of geometrical misses with, as a consequence, under-dosage of the tumor and/or overdosage of healthy tissues. Geometric uncertainties due to respiratory movements or set-up errors are well known. Two strategies have been proposed to limit their effect: quantification of these uncertainties, which are then taken into account in the final calculation of safety margins and/or reduction of respiratory and set-up uncertainties by an efficient immobilization or gating systems. Measured on portal films with two tangential fields. CLD (central lung distance), defined as the distance between the deep field edge and the interior chest wall at the central axis, seems to be the best predictor of set-up uncertainties. Using CLD, estimated mean set-up errors from the literature are 3.8 and 3.2 mm for the systematic and random errors respectively. These depend partly on the type of immobilization device and could be reduced by the use of portal imaging systems. Furthermore, breast is mobile during respiration with motion amplitude as high as 0.8 to 10 mm in the anteroposterior direction. Respiratory gating techniques, currently on evaluation, have the potential to reduce effect of these movements. Each radiotherapy department should perform its own assessments and determine the geometric uncertainties with respect of the equipment used and its particular treatment practices. This paper is a review of the main geometric uncertainties in breast treatment, due to respiration and set-up, and solutions proposed to limit their impact. (author)

  7. Development of Multiplexed Marker Sets to Identify the Most Relevant Poplar Species for Breeding

    Directory of Open Access Journals (Sweden)

    Hilke Schroeder

    2017-12-01

    Full Text Available Within the genus Populus, about 30 species are classified into six sections, of which some are cross-compatible. Besides naturally occurring hybrids, huge breeding programs have led to a high number of artificially produced hybrids, for which the determination of genetically involved species by morphological characteristics is often difficult. This necessitates the use of molecular markers for the identification of both maternal as well as paternal species, and in the case of complex hybrids, the genealogy. For this reason, we developed new chloroplast and nuclear markers for the differentiation of up to 19 poplar species, with one to 32 individuals per species regularly used in breeding programs based on already known barcoding, other chloroplast regions, and nuclear genes of interest. We developed methods to identify species by either species-specific nucleotide variations or, when no initial information for the species was given, by using a set of markers either in a procedure of exclusion or in a multiplexed marker set. The developed markers can all be used with low-cost equipment, and some can additionally be applied using a genetic analyzer. We combined these markers in multiplexes for a very fast and easy-to-use application for the identification of poplar species and their hybrids.

  8. High dose three-dimensional conformal boost (3DCB) using an orthogonal diagnostic X-ray set-up for patients with gynecological malignancy: a new application of real-time tumor-tracking system

    International Nuclear Information System (INIS)

    Yamamoto, Ritsu; Yonesaka, Akio; Nishioka, Seiko; Watari, Hidemichi; Hashimoto, Takayuki; Uchida, Daichi; Taguchi, Hiroshi; Nishioka, Takeshi; Miyasaka, Kazuo; Sakuragi, Noriaki; Shirato, Hiroki

    2004-01-01

    The feasibility and accuracy of high dose three-dimensional conformal boost (3DCB) using three internal fiducial markers and a two-orthogonal X-ray set-up of the real-time tumor-tracking system on patients with gynecological malignancy were investigated in 10 patients. The standard deviation of the distribution of systematic deviations (Σ) was reduced from 3.8, 4.6, and 4.9 mm in the manual set-up to 2.3, 2.3 and 2.7 mm in the set-up using the internal markers. The average standard deviation of the distribution of random deviations (σ) was reduced from 3.7, 5.0, and 4.5 mm in the manual set-up to 3.3, 3.0, and 4.2 mm in the marker set-up. The appropriate PTV margin was estimated to be 10.2, 12.8, and 12.9 mm in the manual set-up and 6.9, 6.7, and 8.3 mm in the gold marker set-up, respectively, using the formula 2Σ+0.7σ. Set-up of the patients with three markers and two fluoroscopy is useful to reduce PTV margin and perform 3DCB

  9. Computer programmes development for environment variables setting for use with C compiler

    International Nuclear Information System (INIS)

    Sriyotha, P.; Prasertchiewcharn, N.; Yamkate, P.

    1994-01-01

    Compilers generally need special environment variables that operating system has not given at the beginning. Such an environment variables as COMSPEC, PATH, TMP, LIB, INCLUDE can be used as data exchange among programmes.Those variables normally occupy memories and, in some cases, an 'Out of Environment Space' error message frequently occurs when the user set a new environment variable. We would hate to give up in such a situation that just one variable has gotten too large as well as destroying all environment variables. In order to bring everything down to an earth, we try to save an old environment setting, clear and set a new one. Later on, a new setting shall have been cleared and an old one from a saved setting shall have been restored

  10. Effect of cluster set warm-up configurations on sprint performance in collegiate male soccer players.

    Science.gov (United States)

    Nickerson, Brett S; Mangine, Gerald T; Williams, Tyler D; Martinez, Ismael A

    2018-06-01

    The purpose of this study was to determine if back squat cluster sets (CS) with varying inter-repetition rest periods would potentiate greater sprint performance compared with a traditional set parallel back squat in collegiate soccer players. Twelve collegiate male soccer players (age, 21.0 ± 2.0 years; height, 180.0 ± 9.0 cm; body mass, 79.0 ± 9.5 kg) performed a 20-m sprint prior to a potentiation complex and at 1, 4, 7, and 10 min postexercise on 3 separate, randomized occasions. On each occasion, the potentiation complex consisted of 1 set of 3 repetitions at 85% 1-repetition maximum (1RM) for the traditional parallel back squat. However, on 1 occasion the 3-repetition set was performed in a traditional manner (i.e., continuously), whereas on the other 2 occasions, 30s (CS 30 ) and 60 s (CS 60 ) of rest were allotted between each repetition. Repeated-measures ANOVA revealed greater (p = 0.022) mean barbell velocity on CS 60 compared with the traditional set. However, faster (p < 0.040) 20-m sprint times were observed for CS 30 (3.15 ± 0.16 s) compared with traditional (3.20 ± 0.17 s) only at 10 min postexercise. No other differences were observed. These data suggest that a single cluster set of 3 repetitions with 30-s inter-repetition rest periods at 85% 1RM acutely improves 20-m sprinting performance. Strength and conditioning professionals and their athletes might consider its inclusion during the specific warm-up to acutely improve athletic performance during the onset (≤10 min) of training or competition.

  11. A new instrumental set-up for polarized neutron scattering experiments

    International Nuclear Information System (INIS)

    Schmidt, Wolfgang; Ohl, Michael

    2005-01-01

    Neutron scattering with polarization analysis is a powerful tool to determine magnetic structures and excitations. A common setup is to mount the sample at the center of a Helmholtz-type coil which can provide a magnetic field of any direction at the sample position and also a guide field along the neutron flight paths around the sample. Recent experiments showed quite a high demand for measurements at low momentum transfers. For the corresponding low scattering angles air scattering gives rise to a very large background. For this reason we have extended the standard setup to a combination of a large vacuum tank surrounded by electrical coils. The vacuum tank eliminates the air scattering and we can use the polarization analysis down to the lowest accessible momentum transfers. The coils themselves also show some new features: In contrary to the classic (symmetric) coil distribution we use an asymmetric setup which gives the advantage of a larger scattering window. Due to a more sophisticated current distribution this modified coil arrangement needs not to be rotated for different scattering conditions. The whole set-up will soon be available at IN12, a cold neutrons three-axis spectrometer operated by FZ Juelich in collaboration with CEA Grenoble as a CRG-B instrument at the Institut Laue Langevin in Grenoble

  12. An in-beam Compton-suppressed Ge spectrometer for nondestructive neutron activation analysis

    International Nuclear Information System (INIS)

    Zaghloul, R.; Abd El-Haleam, A.; Mostafa, M.; Gantner, E.; Ache, H.J.

    1993-04-01

    A high-efficiency compton background suppressed gamma-ray spectrometer by anti-coincidence counting with a NaI(Tl)-shield around a central HPGe-detector for in-beam prompt gamma-ray neutron activation analysis (AC-PGNAA) using a Cf-252 neutron source has been designed and built to provide simultaneous anti-coincidence spectrometry of natural, industrial and environmental samples. The spectrometer consists of a high-purity germanium detector as the main detector and a large volume cylindrical NaI(Tl) detector as a guard detector. The assembly has the ability to measure instantaneously, simultaneously and nondestructively bulk samples up to about 50 cm 3 . Major constituent elements in several rocks and minerals such as H, B, N, Na, Mg, Al, Si, Cl, K, Ca, P, S, Ti, Fe, Sm, Nd, Mn and Gd can be determined, while oxygen cannot be measured due to its small capture cross section (0.27 mb). Several important minor and trace elements such as B, Cd and Hg beside the low residual activity, rare earths and short-lived isotopes could be detected. The sensitivity of the AC-PGNAA technique is limited by the available neutron flux at the target matrix and the neutron absorption cross section of the elements of interest. PGNAA has the advantage to estimate the constituent elements which are difficult to be measured through the delayed gamm-ray measurements such as B, Bi, C, H, P, Tl, Be, Cl and S in industrial and reference materials and those elements which are transformed into other stable isotopes when undergoing neutron capture. The design of the spectrometer assembly, its properties and performance are described

  13. Set-up and methods for SiPM Photo-Detection Efficiency measurements

    International Nuclear Information System (INIS)

    Zappalà, G.; Acerbi, F.; Ferri, A.; Gola, A.; Paternoster, G.; Zorzi, N.; Piemonte, C.

    2016-01-01

    In this work, a compact set-up and three different methods to measure the Photo-Detection Efficiency (PDE) of Silicon Photomultipliers (SiPMs) and Single-Photon Avalanche Diodes (SPADs) are presented. The methods, based on either continuous or pulsed light illumination, are discussed in detail and compared in terms of measurement precision and time. For the SiPM, these methods have the feature of minimizing the effect of both the primary and correlated noise on the PDE estimation. The PDE of SiPMs (produced at FBK, Trento, Italy) was measured in a range from UV to NIR, obtaining similar results with all the methods. Furthermore, the advantages of measuring, when possible, the PDE of SPADs (of the same technology and with the same layout of a single SiPM cell) instead of larger devices are also discussed and a direct comparison between measurement results is shown. Using a SPAD, it is possible to reduce the measurement complexity and uncertainty since the correlated noise sources are reduced with respect to the SiPM case.

  14. HUG sets up an emergency operations centre on the CERN site

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    Discussions between CERN and the Hôpitaux universitaires de Genève (HUG), under the aegis of the Swiss authorities, have resulted in the setting-up of an emergency operations centre on the CERN site. This will be the operations base for an emergency doctor, a medical emergency vehicle and a driver. Located on the Swiss part of the Meyrin site, close to Building 57, it will be inaugurated on 20 May.   SMUR team based at CERN. CERN’s medical staff and fire-fighters dispense first aid but in medical emergencies they are obliged to call on outside services to treat and transfer patients to hospital. In the Canton of Geneva, this service is provided by HUG via the 144 emergency line. But HUG is based on the eastern side of Geneva, a long way from CERN, and response times can be substantial. In order to improve the safety of the growing number of people on the site, CERN asked Switzerland, as one of its Host States, to help it reduce the medical emergency response t...

  15. Set-up improvement in head and neck radiotherapy using a 3D off-line EPID-based correction protocol and a customised head and neck support

    International Nuclear Information System (INIS)

    Lin, Emile N.J. Th. van; Vight, Lisette van der; Huizenga, Henk; Kaanders, Johannes H.A.M.; Visser, Andries G.

    2003-01-01

    Purpose: First, to investigate the set-up improvement resulting from the introduction of a customised head and neck (HN) support system in combination with a technologist-driven off-line correction protocol in HN radiotherapy. Second, to define margins for planning target volume definition, accounting for systematic and random set-up uncertainties. Methods and materials: In 63 patients 498 treatment fractions were evaluated to develop and implement a 3D shrinking action level correction protocol. In the comparative study two different HN-supports were compared: a flexible 'standard HN-support' and a 'customised HN-support'. For all three directions (x, y and z) random and systematic set-up deviations (1 S.D.) were measured. Results: The customised HN-support improves the patient positioning compared to the standard HN-support. The 1D systematic errors in the x, y and z directions were reduced from 2.2-2.3 mm to 1.2-2.0 mm (1 S.D.). The 1D random errors for the y and z directions were reduced from 1.6 and 1.6 mm to 1.1 and 1.0 mm (1 S.D.). The correction protocol reduced the 1D systematic errors further to 0.8-1.1 mm (1 S.D.) and all deviations in any direction were within 5 mm. Treatment time per measured fraction was increased from 10 to 13 min. The total time required per patient, for the complete correction procedure, was approximately 40 min. Conclusions: Portal imaging is a powerful tool in the evaluation of the department specific patient positioning procedures. The introduction of a comfortable customised HN-support, in combination with an electronic portal imaging device-based correction protocol, executed by technologists, led to an improvement of overall patient set-up. As a result, application of proposed recipes for CTV-PTV margins indicates that these can be reduced to 3-4 mm

  16. Lay-up practices at EDF PWR fleet and future developments

    International Nuclear Information System (INIS)

    Alos Ramos, O.; Wintergest, M.; De Maria Pablo, S.; Postic, A.; Courtaudiere, J.P.; Fournier, C.; Vialette, R.; Waeber, J.; Couturier, D.; Robillart, P.

    2015-01-01

    A proper lay-up can only be achieved by plant specific lay-up procedures. The lay-up control practices are necessary to prevent corrosion damage during shut down and are an important part of the life extension of a nuclear power plant. EDF operational experience in this area confirms that damage to plant equipment from improper lay-up procedures is a cause of reduced plant reliability and availability and can increase the corrosion products ingress into the SG during start-up. This article presents the EDF lay-up program and the improvement of lay-up practices. It provides information on the lay-up procedures, best practices and recommendations, operating experience, considerations for different durations of outages; the implementation of a preservation working group, the selection of the systems that will be included in the lay-up program and the material damage characterization in some auxiliary systems. Finally, future developments will be presented, such as the development of a 'convective model' to determine air requirements (humidity, flow rate...) and the drying rate to dry a heat exchanger. (authors)

  17. 准确设置会计科目的意义与方法%The Meaning and Methods of Setting up Accounting Subject Accurately

    Institute of Scientific and Technical Information of China (English)

    刘海; 孙胜

    2013-01-01

      管理会计的产生与发展,是会计发展史上的一次伟大变革,它让会计工作的价值得到了有效地升华。而恰当的设置会计科目,对经济数据进行有效地分类、归集自然成为了会计信息管理的核心工作。本文从准确设置会计科目的重要意义、会计科目设置原则、会计科目设置方法方面进行了论述,为企业财务管理与经济管理提供参考依据。%The origin and development of management accounting is a great change in the history of the accounting development, it gives effective sublimation for the value of the accounting work. Proper setting up accounting subject, effectively sorting and collecting the economic data has become the core work of the accounting information management. This article discussed from the significance, principle and the method of accurately setting up accounting subject, and provided a reference for enterprise financial management and economic management.

  18. Omental deposits surveillance in gynecological malignancies at first setting follow up: 18F-FDG PET/CT compared to CT

    OpenAIRE

    Tamer W. Kassem

    2017-01-01

    Objective: The aim of this study was to compare the diagnostic performance of positron emission tomography/computed tomography (PET/CT) scan and CT scan in follow up of proven gynecological malignancies omental deposits in first setting follow up after treatment. Patients and methods: 60 female patients having proven omental deposits from gynecological malignancies underwent PET/CT examination following a preset protocol as baseline study. 34 cases of them had a second PET/CT examination f...

  19. Predicting death from kala-azar: construction, development, and validation of a score set and accompanying software.

    Science.gov (United States)

    Costa, Dorcas Lamounier; Rocha, Regina Lunardi; Chaves, Eldo de Brito Ferreira; Batista, Vivianny Gonçalves de Vasconcelos; Costa, Henrique Lamounier; Costa, Carlos Henrique Nery

    2016-01-01

    Early identification of patients at higher risk of progressing to severe disease and death is crucial for implementing therapeutic and preventive measures; this could reduce the morbidity and mortality from kala-azar. We describe a score set composed of four scales in addition to software for quick assessment of the probability of death from kala-azar at the point of care. Data from 883 patients diagnosed between September 2005 and August 2008 were used to derive the score set, and data from 1,031 patients diagnosed between September 2008 and November 2013 were used to validate the models. Stepwise logistic regression analyses were used to derive the optimal multivariate prediction models. Model performance was assessed by its discriminatory accuracy. A computational specialist system (Kala-Cal(r)) was developed to speed up the calculation of the probability of death based on clinical scores. The clinical prediction score showed high discrimination (area under the curve [AUC] 0.90) for distinguishing death from survival for children ≤2 years old. Performance improved after adding laboratory variables (AUC 0.93). The clinical score showed equivalent discrimination (AUC 0.89) for older children and adults, which also improved after including laboratory data (AUC 0.92). The score set also showed a high, although lower, discrimination when applied to the validation cohort. This score set and Kala-Cal(r) software may help identify individuals with the greatest probability of death. The associated software may speed up the calculation of the probability of death based on clinical scores and assist physicians in decision-making.

  20. Points in the set-up of tests for fMRI. Toward the delineation of language-competent areas in clinical practice

    International Nuclear Information System (INIS)

    Takashima, Hisaharu; Ejima, Mitsuhiro; Takeyama, Mamoru; Yamaguchi, Masami; Sato, Yoshino

    2001-01-01

    This hospital has performed fMRI of language-competent areas of the brain to identify the language-dominant hemisphere and obtain the configuration of the focus in the language-dominant side of the brain. Until now, signals have been detected in only two of fifteen patients who were diagnosed by language tests of a last-syllable word chain. In the present experiment, we tried to have subjects select the type of test. The result was that changes in signals were detected in eight of ten patients. Although the set-up of tests for fMRI is said to hold significant value, clear-cut studies to back this up have rarely been seen. Because clinical medicine treats patients who have difficulty in communication or suffer from aphasia, it is important to take into consideration individual variations and to set up a test suitable for, or achievable by, these individuals. The present method enabled us to avoid failure in examination caused by unsuccessful tests. (author)

  1. Points in the set-up of tests for fMRI. Toward the delineation of language-competent areas in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Takashima, Hisaharu; Ejima, Mitsuhiro; Takeyama, Mamoru; Yamaguchi, Masami; Sato, Yoshino [Tokyo Women' s Medical Coll. (Japan). Hospital

    2001-06-01

    This hospital has performed fMRI of language-competent areas of the brain to identify the language-dominant hemisphere and obtain the configuration of the focus in the language-dominant side of the brain. Until now, signals have been detected in only two of fifteen patients who were diagnosed by language tests of a last-syllable word chain. In the present experiment, we tried to have subjects select the type of test. The result was that changes in signals were detected in eight of ten patients. Although the set-up of tests for fMRI is said to hold significant value, clear-cut studies to back this up have rarely been seen. Because clinical medicine treats patients who have difficulty in communication or suffer from aphasia, it is important to take into consideration individual variations and to set up a test suitable for, or achievable by, these individuals. The present method enabled us to avoid failure in examination caused by unsuccessful tests. (author)

  2. Setting up decommissioning funds for nuclear facilities - a competence problem for EURATOM

    International Nuclear Information System (INIS)

    Danwitz, Th. von

    2003-01-01

    The nuclear package presented by the European Commission in the autumn of 2002 has added considerable practical significance to the problem of the vertical limits of competence between the Community and its member states within the framework of the Euratom Treaty. The question most important to Germany is the authority of the European Atomic Energy Community to oblige its member states to set up funds for financing the decommissioning of nuclear facilities. As the Euratom Treaty contains no explicit competences of Euratom for regulations of this type, the article examines the content and range of Art. 30 ff. of the Euratom Treaty, the unwritten authority resulting from factual connections and the nature of the problems involved, looks at the importance of international agreements as far as legal competences are implied, and deals with a possible competence based on the right to amend the Treaty under Art. 203, Euratom Treaty. (orig.) [de

  3. 'When measurements mean action' decision models for portal image review to eliminate systematic set-up errors

    International Nuclear Information System (INIS)

    Wratten, C.R.; Denham, J.W.; O; Brien, P.; Hamilton, C.S.; Kron, T.; London Regional Cancer Centre, London, Ontario

    2004-01-01

    The aim of the present paper is to evaluate how the use of decision models in the review of portal images can eliminate systematic set-up errors during conformal therapy. Sixteen patients undergoing four-field irradiation of prostate cancer have had daily portal images obtained during the first two treatment weeks and weekly thereafter. The magnitude of random and systematic variations has been calculated by comparison of the portal image with the reference simulator images using the two-dimensional decision model embodied in the Hotelling's evaluation process (HEP). Random day-to-day set-up variation was small in this group of patients. Systematic errors were, however, common. In 15 of 16 patients, one or more errors of >2 mm were diagnosed at some stage during treatment. Sixteen of the 23 errors were between 2 and 4 mm. Although there were examples of oversensitivity of the HEP in three cases, and one instance of undersensitivity, the HEP proved highly sensitive to the small (2-4 mm) systematic errors that must be eliminated during high precision radiotherapy. The HEP has proven valuable in diagnosing very small ( 4 mm) systematic errors using one-dimensional decision models, HEP can eliminate the majority of systematic errors during the first 2 treatment weeks. Copyright (2004) Blackwell Science Pty Ltd

  4. Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Pallotta, Stefania; Bucciolini, Marta [Universita degli Studi di Firenze, Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Florence (Italy); AOU Careggi, Sezione di Fisica Medica, Florence (Italy); Vanzi, Eleonora; Marrazzo, Livia [AOU Careggi, Sezione di Fisica Medica, Florence (Italy); Simontacchi, Gabriele; Paiar, Fabiola [AOU Careggi, Sezione di Radioterapia, Florence (Italy); Ceroti, Marco [ISPO, U.O. Epidemiologia Molecolare e Nutrizionale, Florence (Italy); Livi, Lorenzo [Universita degli Studi di Firenze, Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Florence (Italy); AOU Careggi, Sezione di Radioterapia, Florence (Italy)

    2015-09-15

    The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57 % of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73 % of the cases, while the use of SA was beneficial in only 45 %. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions. (orig.) [German] Ziel dieser Studie ist der Vergleich der Patientenpositionierung mittels der 3-D/4-D-Erfassung der Patientenoberflaeche durch ein Abtastsystem, kV/MV-Verifikationsaufnahmen mit Hochenergiebildsystemen und Markierungen auf der Haut bei Bestrahlungen im Thorax- bzw. Beckenbereich. Als Goldstandard zum Vergleich dienten CBCT(''cone beam computed tomography'')-Aufnahmen. Die Studie basiert auf Untersuchungen an 20 Patienten. Es wurden

  5. A knowledge brokerage approach for assessing the impacts of the setting up young farmers policy measure in Greece

    International Nuclear Information System (INIS)

    Bournaris, Th.; Moulogianni, Ch.; Arampatzis, S.; Kiomourtzi, F.; Wascher, D.M.; Manos, B.

    2016-01-01

    This study explores Knowledge Brokerage (KB) aspects of an ex-post Impact Assessment (IA) for the Rural Development Programme (RDP) measure of setting up young farmers, under the Common Agricultural Policy (CAP), at the regional level in Northern Greece. The measure supports the entry of young farmers in agriculture by moving land from older to younger farmers. The aim of the study was to test a set of KB tools for improving the interaction between researchers and policy makers. Our analysis mainly focused on a suite of IA Support Modules to guide practitioners, and on a technical tool kit, a web-based contextualisation platform, to support the IA of the specific test case. Offering a structured approach towards IA, both the Support Modules and LIAISE-KIT allow framing the context, organisation, scheduling and method selection in the light of KB objectives. The evaluation of how IA Support Modules influence the Science Policy Interface (SPI), in the case of the ex-post assessment, demonstrated the high relevance of KB activities for facilitating the interaction between researchers and regional policy makers. The assessment bridges the gap between knowledge producers developing scientific output to be applied in a specific context, and knowledge users, who want clear messages regarding the policy challenges they face. Other conclusions include the need for specific guidelines and training for knowledge users, especially with regard to the use of tools. According to our findings, a consequent application of KB activities is a crucial pre-condition for successfully implementing IAs in future RDP measures.

  6. A knowledge brokerage approach for assessing the impacts of the setting up young farmers policy measure in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Bournaris, Th.; Moulogianni, Ch.; Arampatzis, S.; Kiomourtzi, F. [Aristotle University of Thessaloniki (Greece); Wascher, D.M. [Alterra Wageningen UR (Netherlands); Manos, B., E-mail: manosb@agro.auth.gr [Aristotle University of Thessaloniki (Greece)

    2016-02-15

    This study explores Knowledge Brokerage (KB) aspects of an ex-post Impact Assessment (IA) for the Rural Development Programme (RDP) measure of setting up young farmers, under the Common Agricultural Policy (CAP), at the regional level in Northern Greece. The measure supports the entry of young farmers in agriculture by moving land from older to younger farmers. The aim of the study was to test a set of KB tools for improving the interaction between researchers and policy makers. Our analysis mainly focused on a suite of IA Support Modules to guide practitioners, and on a technical tool kit, a web-based contextualisation platform, to support the IA of the specific test case. Offering a structured approach towards IA, both the Support Modules and LIAISE-KIT allow framing the context, organisation, scheduling and method selection in the light of KB objectives. The evaluation of how IA Support Modules influence the Science Policy Interface (SPI), in the case of the ex-post assessment, demonstrated the high relevance of KB activities for facilitating the interaction between researchers and regional policy makers. The assessment bridges the gap between knowledge producers developing scientific output to be applied in a specific context, and knowledge users, who want clear messages regarding the policy challenges they face. Other conclusions include the need for specific guidelines and training for knowledge users, especially with regard to the use of tools. According to our findings, a consequent application of KB activities is a crucial pre-condition for successfully implementing IAs in future RDP measures.

  7. Core Outcome Set-STAndards for Development: The COS-STAD recommendations.

    Directory of Open Access Journals (Sweden)

    Jamie J Kirkham

    2017-11-01

    Full Text Available The use of core outcome sets (COS ensures that researchers measure and report those outcomes that are most likely to be relevant to users of their research. Several hundred COS projects have been systematically identified to date, but there has been no formal quality assessment of these studies. The Core Outcome Set-STAndards for Development (COS-STAD project aimed to identify minimum standards for the design of a COS study agreed upon by an international group, while other specific guidance exists for the final reporting of COS development studies (Core Outcome Set-STAndards for Reporting [COS-STAR].An international group of experienced COS developers, methodologists, journal editors, potential users of COS (clinical trialists, systematic reviewers, and clinical guideline developers, and patient representatives produced the COS-STAD recommendations to help improve the quality of COS development and support the assessment of whether a COS had been developed using a reasonable approach. An open survey of experts generated an initial list of items, which was refined by a 2-round Delphi survey involving nearly 250 participants representing key stakeholder groups. Participants assigned importance ratings for each item using a 1-9 scale. Consensus that an item should be included in the set of minimum standards was defined as at least 70% of the voting participants from each stakeholder group providing a score between 7 and 9. The Delphi survey was followed by a consensus discussion with the study management group representing multiple stakeholder groups. COS-STAD contains 11 minimum standards that are the minimum design recommendations for all COS development projects. The recommendations focus on 3 key domains: the scope, the stakeholders, and the consensus process.The COS-STAD project has established 11 minimum standards to be followed by COS developers when planning their projects and by users when deciding whether a COS has been developed using

  8. Core Outcome Set-STAndards for Development: The COS-STAD recommendations.

    Science.gov (United States)

    Kirkham, Jamie J; Davis, Katherine; Altman, Douglas G; Blazeby, Jane M; Clarke, Mike; Tunis, Sean; Williamson, Paula R

    2017-11-01

    The use of core outcome sets (COS) ensures that researchers measure and report those outcomes that are most likely to be relevant to users of their research. Several hundred COS projects have been systematically identified to date, but there has been no formal quality assessment of these studies. The Core Outcome Set-STAndards for Development (COS-STAD) project aimed to identify minimum standards for the design of a COS study agreed upon by an international group, while other specific guidance exists for the final reporting of COS development studies (Core Outcome Set-STAndards for Reporting [COS-STAR]). An international group of experienced COS developers, methodologists, journal editors, potential users of COS (clinical trialists, systematic reviewers, and clinical guideline developers), and patient representatives produced the COS-STAD recommendations to help improve the quality of COS development and support the assessment of whether a COS had been developed using a reasonable approach. An open survey of experts generated an initial list of items, which was refined by a 2-round Delphi survey involving nearly 250 participants representing key stakeholder groups. Participants assigned importance ratings for each item using a 1-9 scale. Consensus that an item should be included in the set of minimum standards was defined as at least 70% of the voting participants from each stakeholder group providing a score between 7 and 9. The Delphi survey was followed by a consensus discussion with the study management group representing multiple stakeholder groups. COS-STAD contains 11 minimum standards that are the minimum design recommendations for all COS development projects. The recommendations focus on 3 key domains: the scope, the stakeholders, and the consensus process. The COS-STAD project has established 11 minimum standards to be followed by COS developers when planning their projects and by users when deciding whether a COS has been developed using reasonable

  9. New set-up for high-quality soft-X-ray absorption spectroscopy of large organic molecules in the gas phase

    Energy Technology Data Exchange (ETDEWEB)

    Holch, Florian; Huebner, Dominique [Universitaet Wuerzburg, Experimentelle Physik VII, Am and Roentgen Reasearch Center for Complex Materials (RCCM) Hubland, 97074 Wuerzburg (Germany); Fink, Rainer [Universitaet Erlangen-Nuernberg, ICMM and CENEM, Egerlandstrasse 3, 91058 Erlangen (Germany); Schoell, Achim, E-mail: achim.schoell@physik.uni-wuerzburg.de [Universitaet Wuerzburg, Experimentelle Physik VII, Am and Roentgen Reasearch Center for Complex Materials (RCCM) Hubland, 97074 Wuerzburg (Germany); Umbach, Eberhard [Karlsruhe Institute of Technology, 76021 Karlsruhe (Germany)

    2011-11-15

    Highlights: {yields} We present a new set-up for x-ray absorption (NEXAFS) on large molecules in the gas-phase. {yields} The cell has a confined volume and can be heated. {yields} The spectra can be acquired fast, are of very high quality with respect tosignal-to-noise ratio and energy resolution. {yields} This allowsthe analysis of spectroscopic details (e.g. solid state effects by comparing gas- and condensed phase data). - Abstract: We present a new experimental set-up for the investigation of large (>128 amu) organic molecules in the gas-phase by means of near-edge X-ray absorption fine structure spectroscopy in the soft X-ray range. Our approach uses a gas cell, which is sealed off against the surrounding vacuum and which can be heated above the sublimation temperature of the respective molecular compound. Using a confined volume rather than a molecular beam yields short acquisition times and intense signals due to the high molecular density, which can be tuned by the container temperature. In turn, the resulting spectra are of very high quality with respect to signal-to-noise ratio and energy resolution, which are the essential aspects for the analysis of fine spectroscopic details. Using the examples of ANQ, NTCDA, and PTCDA, specific challenges of gas phase measurements on large organic molecules with high sublimation temperatures are addressed in detail with respect to the presented set-up and possible ways to tackle them are outlined.

  10. Social and cultural resources for the setting up and functioning of family enterprises in a small Bulgarian town

    Directory of Open Access Journals (Sweden)

    Petrova Ivanka

    2015-01-01

    Full Text Available As a field of culture, the family enterprise shows that in the current European societies the economic operation does not proceed only from a purely rational point of view and that notwithstanding the common speaking of globalization, the local may be a prerequisite for successful economic development. My objective has been to show, proceeding from an example from a small Bulgarian town, that the family enterprise is a field of culture in which the observed phenomena are strongly influenced by the social inclusion of the enterprise and by its tie-up with the context of the urban environment. I shall investigate in what way local social and cultural resources are intensively used in the process of setting up and functioning of a family enterprise from the sphere of hoteldom and tourism in the town of Belogradchik. I intend to study whether these resources are conducive to the economic prosperity of the firm. Another research objective is to establish the manner of identification of the enterprise with the town, with the region and the local culture by way of the services provided (tourist and restaurant. I shall look for an answer to the question of how the enterprise’ working realm fits in the concrete cultural, historical and social context of the town.

  11. ECONOMIC EVALUATION OF A BREEDING PROGRAMME FOR SETTING UP TWO HIGH PERFORMANCES BEE LINES

    Directory of Open Access Journals (Sweden)

    A POPESCU

    2003-10-01

    Full Text Available This study aimed to evaluate costs, incomes and financial results related to the creation of two Apis Mellifica Carpatica lines, based on a specific Breeding Programme within a closed population. The two beelines have been carefully selected for the bee populations living in two areas of Romania: North Moldavia and South Muntenia. A new selection technology is set up in order to produce high performance queen bees, well adapted to the environmental conditions mainly to picking. Genetic gain will be get by selling the mated selected queens belonging to the two lines to various beekeepers interested to obtain more and high quality bee products.

  12. Set-up of experiment R606

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Experiment R606 (Aachen, CERN, Harvard, Munich, Northwestern, Riverside)installed in the specially constructed pit at intersection 6. It was designed to investigate production of new particles in the fragmentation and diffraction regions. Use was made of a toroidal field provided by 12 flat copper coils, seen here as the rays of a wheel; in the free spaces between coils are housed Cerenkov counters. These counters, together with calorimetric shower detectors, located behind the magnet, provide separation of electrons from hadrons. The momenta of particles going through the system are measured with two sets of three drift chambers, two in front of the magnet, one behind, whose size increases from 1.5 m for the one seen in the picture, to 5 m for the one on the back. On the right the thin- walled cylindrical vacuum chamber.

  13. Ophthalmic Start-Up Chief Executive Officers' Perceptions of Development Hurdles.

    Science.gov (United States)

    Stewart, William C; Nelson, Lindsay A; Kruft, Bonnie; Stewart, Jeanette A

    2018-01-01

    To identify current challenges facing ophthalmic pharmaceutical start-ups in developing new products. Surveys were distributed to the chief executive officer (CEO) or president of ophthalmic start-ups. The survey attracted 24 responses from 78 surveys distributed (31%). The CEOs stated that a lack of financial capital (n = 18, 75%), FDA regulations (n = 6, 25%), and failure to meet clinical endpoints (n = 6, 25%) were their greatest development hurdles. Risk aversion to medicines in early development (n = 18, 75%), mergers and acquisitions reducing corporate choice for licensing agreements (n = 7, 29%), the emergence of large pharmaceutical-based venture capital funding groups (n = 12, 50%), and the failure of many large pharmaceutical companies to develop their own medicines (n = 10, 42%) were noted as recent prominent trends affecting fundraising. The study suggests that development funding, regulatory burden, and meeting clinical endpoints are the greatest development challenges faced by ophthalmic start-up CEOs. © 2017 S. Karger AG, Basel.

  14. Radiation reaction studies in an all-optical set-up: experimental limitations

    Science.gov (United States)

    Samarin, G. M.; Zepf, M.; Sarri, G.

    2018-06-01

    The recent development of ultra-high intensity laser facilities is finally opening up the possibility of studying high-field quantum electrodynamics in the laboratory. Arguably, one of the central phenomena in this area is that of quantum radiation reaction experienced by an ultra-relativistic electron beam as it propagates through the tight focus of a laser beam. In this paper, we discuss the major experimental challenges that are to be faced in order to extract meaningful and quantitative information from this class of experiments using existing and near-term laser facilities.

  15. Analysis of Pick-Up Development in Punching

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2002-01-01

    The development of pick-up of work piece material on the punch surface with increasing number of strokes during punching of stainless steel sheet is investigated applying Scanning Electron Microscopy (SEM), 3D roughness mapping and measurements of the backstroke force. It is found that pick...

  16. Discussion on an informative system set-up for the registration and processing of reliability data on FBR components in view of its application to design and safety studies and plant exploitation improvement

    International Nuclear Information System (INIS)

    Righini, R.; Sola, P.G.; Zappellini, G.

    1990-01-01

    This report describes the set-up and management activities carried-out by ENEA-VEL in collaboration with NIER in the development of a reliability data bank on fast reactor components; this data bank consists of an informative system implemented on the IBM 3090 computer of the ENEA centre of Bologna starting from the software of the CEDB, set-up by CCR Euratom of Ispra for the registration of reliability data on thermal reactor components. This report will contain a detailed description of all the modules (engineering, operating, etc.) provided in the informative system and of the modifications introduced by ENEA in order to adapt them to the peculiarities of the fast reactors and to increase its flexibility; a short description of the available data processing methods will be also included. It will be followed by a comparison between the results obtained applying the classical methods and the particular ones set-up by ENEA: this comparison will be useful to demonstrate the importance of the method applied in order to obtain significative reliability processed data. This report will be also useful to show the importance of the set-up data bank in the improvement of the component design and of the plant safety and exploitation with particular reference to the research of the critical areas and to the definition of the best inspection and maintenance programs

  17. Practical performance for CT simulator set up and commissioning for 3d radiotherapy

    International Nuclear Information System (INIS)

    Wang, Y.; Rinks, A.; Zealey, W.

    2004-01-01

    Full text: We present a summary of the protocol used to commission two GE LightSpeed and One Siemens CT-Sim for 3D radiotherapy in early 2004. The protocol defined was based on AAPM TG-66 and ACPSEM 1997 position paper. Scanning Med-TEC Iso-align Laser Alignment Device for three-D isocentre alignment 1. Couch Movement Accuracy for both manual and scanning movement checked before isocentre alignment, as the reference distance is required for the external isocentre setup. 2. Gantry scan rotation circle vertical and tilted angle alignment checked by overlaying the vertical and horizontal image coordinate lines using the aligned ball-bearings in the phantom to determine the gantry cross plane image vertical accuracy and tilt angle accuracy. 3. Zero scan position determined by scanning the horizontally set Med-Align phantom, and adjusting the phantom position forward and backward to match the image scanning centre. 4. Internal lasers position determined by the position of aligned Med-Align phantom after the scanning centre determined. 5. Couch top to Gantry Perpendicular checked by matching the couch axis in the longitudinal and lateral direction to the position of the laser lines determined according to the CT scanning orientation. 6. Couch Central Axis aligned to ensure the couch travels though the internal isocentre for the full range of longitudinal of movement. 7. External isocentre and laser focus can be determined by moving the couch back a set distance (50cm or 60cm normally) from the internal isocentre. Planning image transfer and DRR image alignment 1. Scanning Centre indicated on the planning image depends on the functionality of the planning system. Some planning systems load the image with the scanning centre at zero position, others load up the image with the absolute distance. 2. Zero Slice position aligned to the centre of the phantom using the external laser. 3. Orientation and Distance were checked by scanning the Iso-align in both vertical and

  18. Psychometric evaluation of 3-set 4P questionnaire.

    Science.gov (United States)

    Akerman, Eva; Fridlund, Bengt; Samuelson, Karin; Baigi, Amir; Ersson, Anders

    2013-02-01

    This is a further development of a specific questionnaire, the 3-set 4P, to be used for measuring former ICU patients' physical and psychosocial problems after intensive care and the need for follow-up. The aim was to psychometrically test and evaluate the 3-set 4P questionnaire in a larger population. The questionnaire consists of three sets: "physical", "psychosocial" and "follow-up". The questionnaires were sent by mail to all patients with more than 24-hour length of stay on four ICUs in Sweden. Construct validity was measured with exploratory factor analysis with Varimax rotation. This resulted in three factors for the "physical set", five factors for the "psychosocial set" and four factors for the "follow-up set" with strong factor loadings and a total explained variance of 62-77.5%. Thirteen questions in the SF-36 were used for concurrent validity showing Spearman's r(s) 0.3-0.6 in eight questions and less than 0.2 in five. Test-retest was used for stability reliability. In set follow-up the correlation was strong to moderate and in physical and psychosocial sets the correlations were moderate to fair. This may have been because the physical and psychosocial status changed rapidly during the test period. All three sets had good homogeneity. In conclusion, the 3-set 4P showed overall acceptable results, but it has to be further modified in different cultures before being considered a fully operational instrument for use in clinical practice. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Validation of an air–liquid interface toxicological set-up using Cu, Pd, and Ag well-characterized nanostructured aggregates and spheres

    International Nuclear Information System (INIS)

    Svensson, C. R.; Ameer, S. S.; Ludvigsson, L.; Ali, N.; Alhamdow, A.; Messing, M. E.; Pagels, J.; Gudmundsson, A.; Bohgard, M.; Sanfins, E.; Kåredal, M.; Broberg, K.; Rissler, J.

    2016-01-01

    Systems for studying the toxicity of metal aggregates on the airways are normally not suited for evaluating the effects of individual particle characteristics. This study validates a set-up for toxicological studies of metal aggregates using an air–liquid interface approach. The set-up used a spark discharge generator capable of generating aerosol metal aggregate particles and sintered near spheres. The set-up also contained an exposure chamber, The Nano Aerosol Chamber for In Vitro Toxicity (NACIVT). The system facilitates online characterization capabilities of mass mobility, mass concentration, and number size distribution to determine the exposure. By dilution, the desired exposure level was controlled. Primary and cancerous airway cells were exposed to copper (Cu), palladium (Pd), and silver (Ag) aggregates, 50–150 nm in median diameter. The aggregates were composed of primary particles <10 nm in diameter. For Cu and Pd, an exposure of sintered aerosol particles was also produced. The doses of the particles were expressed as particle numbers, masses, and surface areas. For the Cu, Pd, and Ag aerosol particles, a range of mass surface concentrations on the air–liquid interface of 0.4–10.7, 0.9–46.6, and 0.1–1.4 µg/cm"2, respectively, were achieved. Viability was measured by WST-1 assay, cytokines (Il-6, Il-8, TNF-a, MCP) by Luminex technology. Statistically significant effects and dose response on cytokine expression were observed for SAEC cells after exposure to Cu, Pd, or Ag particles. Also, a positive dose response was observed for SAEC viability after Cu exposure. For A549 cells, statistically significant effects on viability were observed after exposure to Cu and Pd particles. The set-up produced a stable flow of aerosol particles with an exposure and dose expressed in terms of number, mass, and surface area. Exposure-related effects on the airway cellular models could be asserted.Graphical Abstract

  20. Validation of an air–liquid interface toxicological set-up using Cu, Pd, and Ag well-characterized nanostructured aggregates and spheres

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, C. R., E-mail: christian.svensson@design.lth.se [Lund University, Department of Design Sciences, Ergonomics and Aerosol Technology (Sweden); Ameer, S. S. [Lund University, Division of Occupational and Environmental Medicine, Department of Laboratory Medicine (Sweden); Ludvigsson, L. [Lund University, Department of Physics, Solid State Physics (Sweden); Ali, N.; Alhamdow, A. [Lund University, Division of Occupational and Environmental Medicine, Department of Laboratory Medicine (Sweden); Messing, M. E. [Lund University, Department of Physics, Solid State Physics (Sweden); Pagels, J.; Gudmundsson, A.; Bohgard, M. [Lund University, Department of Design Sciences, Ergonomics and Aerosol Technology (Sweden); Sanfins, E. [Atomic Energy Commission (CEA), Institute of Emerging Diseases and Innovative Therapies (iMETI), Division of Prions and Related Diseases - SEPIA (France); Kåredal, M.; Broberg, K. [Lund University, Division of Occupational and Environmental Medicine, Department of Laboratory Medicine (Sweden); Rissler, J. [Lund University, Department of Design Sciences, Ergonomics and Aerosol Technology (Sweden)

    2016-04-15

    Systems for studying the toxicity of metal aggregates on the airways are normally not suited for evaluating the effects of individual particle characteristics. This study validates a set-up for toxicological studies of metal aggregates using an air–liquid interface approach. The set-up used a spark discharge generator capable of generating aerosol metal aggregate particles and sintered near spheres. The set-up also contained an exposure chamber, The Nano Aerosol Chamber for In Vitro Toxicity (NACIVT). The system facilitates online characterization capabilities of mass mobility, mass concentration, and number size distribution to determine the exposure. By dilution, the desired exposure level was controlled. Primary and cancerous airway cells were exposed to copper (Cu), palladium (Pd), and silver (Ag) aggregates, 50–150 nm in median diameter. The aggregates were composed of primary particles <10 nm in diameter. For Cu and Pd, an exposure of sintered aerosol particles was also produced. The doses of the particles were expressed as particle numbers, masses, and surface areas. For the Cu, Pd, and Ag aerosol particles, a range of mass surface concentrations on the air–liquid interface of 0.4–10.7, 0.9–46.6, and 0.1–1.4 µg/cm{sup 2}, respectively, were achieved. Viability was measured by WST-1 assay, cytokines (Il-6, Il-8, TNF-a, MCP) by Luminex technology. Statistically significant effects and dose response on cytokine expression were observed for SAEC cells after exposure to Cu, Pd, or Ag particles. Also, a positive dose response was observed for SAEC viability after Cu exposure. For A549 cells, statistically significant effects on viability were observed after exposure to Cu and Pd particles. The set-up produced a stable flow of aerosol particles with an exposure and dose expressed in terms of number, mass, and surface area. Exposure-related effects on the airway cellular models could be asserted.Graphical Abstract.

  1. Chlorine detection in fly ash concrete using a portable neutron generator.

    Science.gov (United States)

    Naqvi, A A; Kalakada, Zameer; Al-Matouq, Faris A; Maslehuddin, M; Al-Amoudi, O S B

    2012-08-01

    The chlorine concentration in chloride-contaminated FA cement concrete specimens was measured using a portable neutron generator based prompt gamma-ray neutron activation (PGNAA) setup with the neutron generator and the gamma-ray detector placed side-by-side on one side of the concrete sample. The minimum detectable concentration of chlorine in FA cement concrete measured in the present study was comparable with previous results for larger accelerator based PGNAA setup. It shows the successful application of a portable neutron generator in concrete corrosion studies. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Leadership development through action learning sets: an evaluation study.

    Science.gov (United States)

    Walia, Surinder; Marks-Maran, Di

    2014-11-01

    This article examines the use of action learning sets in a leadership module delivered by a university in south east England. An evaluation research study was undertaking using survey method to evaluate student engagement with action learning sets, and their value, impact and sustainability. Data were collected through a questionnaire with a mix of Likert-style and open-ended questions and qualitative and quantitative data analysis was undertaken. Findings show that engagement in the action learning sets was very high. Action learning sets also had a positive impact on the development of leadership knowledge and skills and are highly valued by participants. It is likely that they would be sustainable as the majority would recommend action learning to colleagues and would consider taking another module that used action learning sets. When compared to existing literature on action learning, this study offers new insights as there is little empirical literature on student engagement with action learning sets and even less on value and sustainability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. SU-F-I-03: Correction of Intra-Fractional Set-Up Errors and Target Coverage Based On Cone-Beam Computed Tomography for Cervical Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, JY [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China); Hong, DL [The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong (China)

    2016-06-15

    Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed. Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.

  4. The role of relationships in start-up development

    DEFF Research Database (Denmark)

    Mattsson, Jan; Helmersson, Helge; Standing, Craig

    2017-01-01

    Relationships are important in the business start-up phase for a variety of reasons. Internal relationships can support knowledge exchange that determines the business model development and external relationships can facilitate a wide range of opportunities, support and insights. The paper explains...... the key relationships experienced by the founding team of a recently formed Swedish digital trading platform. Data were gathered through a self-reporting diary approach based on the Critical Incident Technique format and texts were analysed by the Pertex text-analytic software. The findings explain how...... important relationships were formed during the initial start-up period targeting international expansion. Interaction with early adopters enabled a rapid evolution of the business platform with the aim to build a community of users to support development....

  5. Order of 2 March 1984 amending Order of 7 November 1979 on the setting up, within the Atomic Energy Commission, of a National Radioactive Waste Management Agency

    International Nuclear Information System (INIS)

    1984-01-01

    This Order amends the Order of 7th November 1979 concerning the setting up, within the CEA, of a National Radioactive Waste Management Agency (ANDRA). In connection with implementing waste storage operations, ANDRA's role remains unchanged; however, it seemed desirable to further strengthen research, development and assessment in the area of radioactive waste policy. These tasks are included in the CEA's responsibilities and are financed by its research budget. (NEA) [fr

  6. Bottom-up priority setting revised. A second evaluation of an institutional intervention in a Swedish health care organisation.

    Science.gov (United States)

    Waldau, Susanne

    2015-09-01

    Transparent priority setting in health care based on specific ethical principles is requested by the Swedish Parliament since 1997. Implementation has been limited. In this case, transparent priority setting was performed for a second time round and engaged an entire health care organisation. Objectives were to refine a bottom-up priority setting process, reach a political decision on service limits to make reallocation towards higher prioritised services possible, and raise systems knowledge. An action research approach was chosen. The national model for priority setting was used with addition of dimensions costs, volumes, gender distribution and feasibility. The intervention included a three step process and specific procedures for each step which were created, revised and evaluated regarding factual and functional aspects. Evaluations methods included analyses of documents, recordings and surveys. Vertical and horizontal priority setting occurred and resources were reallocated. Participants' attitudes remained positive, however less so than in the first priority setting round. Identifying low-priority services was perceived difficult, causing resentment and strategic behaviour. The horizontal stage served to raise quality of the knowledge base, level out differences in ranking of services and raise systems knowledge. Existing health care management systems do not meet institutional requirements for transparent priority setting. Introducing transparent priority setting constitutes a complex institutional reform, which needs to be driven by management/administration. Strong managerial commitment is required. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Friction degradation and set-up effects in hard clays offshore Congo and Angola

    International Nuclear Information System (INIS)

    Colliat, J.L.; Vergobbi, P.; Puech, A.

    1993-01-01

    Piles driven into stiff to hard clays encountered offshore Congo and Angola clearly show both clay-type effects which are (1) friction degradation, with very low driving resistances during continuous driving, and (2) set-up after driving interruptions. Both phenomena were studied by back-analysis of driving records, including results of pile driving monitoring. It allowed one to deduce the friction distribution along the piles during driving; show how the shaft friction at any depth reduces as the pile is driven further into the ground; and show that the shaft friction after driving delays can be close to the estimated static friction capacity of the piles. The SRD calculation method proposed by the authors takes the friction degradation effect into account, leading to improved pile drivability predictions. Four case histories are presented to illustrate the results obtained

  8. Electromagnetic impact by microcellular base stations: analysis and guidelines for a correct setting up

    International Nuclear Information System (INIS)

    Licitra, G.; Reggiani, M.; Silvi, A.M.; Zari, A.; Ricci, A.

    2002-01-01

    During the last few years the development of mobile communications has required ever increasing number of base stations for both existing mobile operators and new ones. More and more users ask for a higher quality services so new technological solutions have been studied and applied to assure effective coverage for given geographical areas, as in squares or narrow streets, characterized by a very high traffic demand or where coverage by usual macro cells is very difficult. On the other side, modern societies of developed countries ask for a better and better quality of life and appropriate government policies. Several studies of national and international scientific organizations have been performed and are still in progress to establish any possible adverse effects on human health of non-ionizing radiation exposure. So, many governments, forced by public opinion pressure, have produced specific standards in agreement with scientific organization guidelines and prudent avoidance politics too. Nowadays, designing their networks, mobile operators have to respect requirements contained in these standards. So a hierarchical cellular system have been recently proposed to comply more easily with both coverage requirements and lower exposure limits. This new coverage strategy of geographical areas requires the presence of microcells beside the usual macro cells. In this paper the study of the distribution of the electromagnetic field levels produced by microcellular base stations characterized by different features and configurations is presented, in order to define a few guidelines for the correct setting up of antennas in compliance with current standard requirements. This is obtained comparing results of theoretical modeling, based on the radio electrical characteristics of each sources, and measurements data. Results achieved by measurements performed on a preliminary sample of microcells have been presented in this work

  9. Exploring the possibilities for setting up sustainable energy systems for the long term: two visions for the Dutch energy system in 2050

    International Nuclear Information System (INIS)

    Treffers, D.J.; Faaij, A.P.C.; Spakman, J.; Seebregts, A.

    2005-01-01

    In this paper, two long-term visions of the Dutch future energy system are composed, analysed and evaluated. Both visions were set up to meet the requirement to reduce the GHG emissions with 80% in 2050 in comparison to 1990. The two visions start from very different perspectives and contexts. Quantitative analysis shows that when economic growth and energy use follow a business as usual development, emissions of GreenHouse Gases (GHG) can increase up to 250% of 1990 levels. The two, rather opposing, visions show that it is feasible to combine (strong) economic growth with far going reduction of GHG emissions, provided a number of key options are developed and applied. These options were chosen and discussed during several meetings by stakeholders in a dialogue process, using feedback from scientists, and consist of improvements in energy efficiency in industry, CO 2 neutral feedstocks for transportation, renewable energy and highly insulated buildings in the built environment and improvements in the primary production of the agricultural sector. It is clear that drastic changes in many areas in society are required to obtain the desired GHG-emission levels in 2050. The results also show though, that such a development can be realised in different ways. In other words, there are various ways to implement a low GHG emission economy in the long term

  10. The Semi-opened Infrastructure Model (SopIM): A Frame to Set Up an Organizational Learning Process

    Science.gov (United States)

    Grundstein, Michel

    In this paper, we introduce the "Semi-opened Infrastructure Model (SopIM)" implemented to deploy Artificial Intelligence and Knowledge-based Systems within a large industrial company. This model illustrates what could be two of the operating elements of the Model for General Knowledge Management within the Enterprise (MGKME) that are essential to set up the organizational learning process that leads people to appropriate and use concepts, methods and tools of an innovative technology: the "Ad hoc Infrastructures" element, and the "Organizational Learning Processes" element.

  11. Operational behavior of the MAP/G/1 queue under N-policy with a single vacation and set-up

    Directory of Open Access Journals (Sweden)

    Ho Woo Lee

    2002-01-01

    Full Text Available This paper considers the MAP/G/1 queue under N-policy with a single vacation and set-up. We derive the vector generating functions of the queue length at an arbitrary time and at departures in decomposed forms. We also derive the Laplace-Stieltjes transform of the waiting time. Computation algorithms for mean performance measures are provided.

  12. Scaling-up Sustainable Aquaculture Development in Sri Lanka ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    ... of Sri Lanka is increasingly emphasizing aquaculture development as a means to foster ... Pilot interventions tested the effectiveness of mobile short text messaging to ... Building on this project, researchers will test three ways of scaling-up ...

  13. The urban boundary-layer field campaign in marseille (ubl/clu-escompte): set-up and first results

    Science.gov (United States)

    Mestayer, P.G.; Durand, P.; Augustin, P.; Bastin, S.; Bonnefond, J.-M.; Benech, B.; Campistron, B.; Coppalle, A.; Delbarre, H.; Dousset, B.; Drobinski, P.; Druilhet, A.; Frejafon, E.; Grimmond, C.S.B.; Groleau, D.; Irvine, M.; Kergomard, C.; Kermadi, S.; Lagouarde, J.-P.; Lemonsu, A.; Lohou, F.; Long, N.; Masson, V.; Moppert, C.; Noilhan, J.; Offerle, B.; Oke, T.R.; Pigeon, G.; Puygrenier, V.; Roberts, S.; Rosant, J.-M.; Sanid, F.; Salmond, J.; Talbaut, M.; Voogt, J.

    The UBL/CLU (urban boundary layer/couche limite urbaine) observation and modelling campaign is a side-project of the regional photochemistry campaign ESCOMPTE. UBL/CLU focuses on the dynamics and thermodynamics of the urban boundary layer of Marseille, on the Mediterranean coast of France. The objective of UBL/CLU is to document the four-dimensional structure of the urban boundary layer and its relation to the heat and moisture exchanges between the urban canopy and the atmosphere during periods of low wind conditions, from June 4 to July 16, 2001. The project took advantage of the comprehensive observational set-up of the ESCOMPTE campaign over the Berre-Marseille area, especially the ground-based remote sensing, airborne measurements, and the intensive documentation of the regional meteorology. Additional instrumentation was installed as part of UBL/CLU. Analysis objectives focus on (i) validation of several energy balance computational schemes such as LUMPS, TEB and SM2-U, (ii) ground truth and urban canopy signatures suitable for the estimation of urban albedos and aerodynamic surface temperatures from satellite data, (iii) high resolution mapping of urban land cover, land-use and aerodynamic parameters used in UBL models, and (iv) testing the ability of high resolution atmospheric models to simulate the structure of the UBL during land and sea breezes, and the related transport and diffusion of pollutants over different districts of the city. This paper presents initial results from such analyses and details of the overall experimental set-up.

  14. Collaborators at domestic jurisdiction: the case of the Basque Government in the setting up of the new Judicial Office in the Basque Country

    Directory of Open Access Journals (Sweden)

    Izaskun Iriarte Irureta

    2011-12-01

    Full Text Available The Administration of Justice in Spain is going through a deep modernisation process aiming both at procedural and organisational reforms. The setting up of the new Judicial Office is precisely the major change of the organisation of the Administration of Justice in the last century. In this context, there is a shift in the role played by the regional governments with responsibilities in the field of Justice, as far as these regional governments are not only collaborators of the Judiciary at domestic jurisdiction, but they also become “actors” as they have decision making powers to create, to design and to organise the common procedural services of the Judicial Office and, hence, to set up the Judicial Office in each judicial district in their territory.This text presents the context and the reasons behind the setting up of the Judicial Office as a new way of organisation of the Spanish Administration of Justice; the Judiciary in Spain and the responsibilities of the regional governments in the Administration of Justice; the meaning of the Judicial Office and its guiding principles; the role of the Basque Government in setting up the Judicial Office in the Basque Country, paying special attention to its activity in the field of standardization of processes, the quality system, and of information, communication and coordination; the results of the first Judicial Offices. Finally the paper questions whether the regional or national governments are just “collaborators” or real “actors” of the Administration of Justice at domestic jurisdiction.

  15. Decree no 76-845 of 1 September 1976 setting up a Council for external nuclear policy

    International Nuclear Information System (INIS)

    1976-01-01

    This Decree has set up a Council for External Nuclear Policy, chaired by the President of the Republic, and includes the Prime Minister, the Ministers for Economy and Finance (these duties are presently discharged by the Prime Minister), Defence, Industry, Trade and Crafts, External Trade, and the Administrator-General of the Commissariat a l'Energie Atomique, as well as the Minister of Foreign Affairs. The duty of this Council is to define the various aspects of external nuclear policy, in particular, regarding the export of technology, equipment and sensitive nuclear products. (NEA) [fr

  16. Computational fluid dynamics simulation of indoor climate in low energy buildings: Computational set up

    Directory of Open Access Journals (Sweden)

    Risberg Daniel

    2017-01-01

    Full Text Available In this paper CFD was used for simulation of the indoor climate in a part of a low energy building. The focus of the work was on investigating the computational set up, such as grid size and boundary conditions in order to solve the indoor climate problems in an accurate way. Future work is to model a complete building, with reasonable calculation time and accuracy. A limited number of grid elements and knowledge of boundary settings are therefore essential. An accurate grid edge size of around 0.1 m was enough to predict the climate according to a grid independency study. Different turbulence models were compared with only small differences in the indoor air velocities and temperatures. The models show that radiation between building surfaces has a large impact on the temperature field inside the building, with the largest differences at the floor level. Simplifying the simulations by modelling the radiator as a surface in the outer wall of the room is appropriate for the calculations. The overall indoor climate is finally compared between three different cases for the outdoor air temperature. The results show a good indoor climate for a low energy building all around the year.

  17. [The development of reagents set in the format of DNA-chip for genetic typing of strains of Vibrio cholerae].

    Science.gov (United States)

    Pudova, E A; Markelov, M L; Dedkov, V G; Tchekanova, T A; Sadjin, A I; Kirdiyashkina, N P; Bekova, M V; Deviyatkin, A A

    2014-05-01

    The necessity of development of methods of genic diagnostic of cholera is conditioned by continuation of the Seventh pandemic of cholera, taxonomic variability of strains of Vibrio cholerae involved into pandemic and also permanent danger of delivery of disease to the territory of the Russian Federation. The methods of genic diagnostic of cholera make it possible in a comparatively short time to maximally minutely characterize strains isolated from patients or their environment. The article presents information about working out reagents set for genetic typing of agents of cholera using DNA-chip. The makeup of DNA-chip included oligonucleotide probes making possible to differentiate strains of V. cholerae on serogroups and biovars and to determine their pathogenicity. The single DNA-chip makes it possible to genetically type up to 12 samples concurrently. At that, duration of analysis without accounting stage of DNA separation makes up to 5 hours. In the progress of work, 23 cholera and non-cholera strains were analyzed. The full compliance of DNA-chip typing results to previously known characteristics of strains. Hence, there is a reason to consider availability of further development of reagents set and possibility of its further application in laboratories of regional level and reference centers.

  18. Investing in the foundation of sustainable development: pathways to scale up for early childhood development

    Science.gov (United States)

    Richter, Linda M; Daelmans, Bernadette; Lombardi, Joan; Heymann, Jody; Boo, Florencia Lopez; Behrman, Jere R; Lu, Chunling; Lucas, Jane E; Perez-Escamilla, Rafael; Dua, Tarun; Bhutta, Zulfiqar A; Stenberg, Karin; Gertler, Paul; Darmstadt, Gary L

    2018-01-01

    Building on long-term benefits of early intervention (Paper 2 of this Series) and increasing commitment to early childhood development (Paper 1 of this Series), scaled up support for the youngest children is essential to improving health, human capital, and wellbeing across the life course. In this third paper, new analyses show that the burden of poor development is higher than estimated, taking into account additional risk factors. National programmes are needed. Greater political prioritisation is core to scale-up, as are policies that afford families time and financial resources to provide nurturing care for young children. Effective and feasible programmes to support early child development are now available. All sectors, particularly education, and social and child protection, must play a role to meet the holistic needs of young children. However, health provides a critical starting point for scaling up, given its reach to pregnant women, families, and young children. Starting at conception, interventions to promote nurturing care can feasibly build on existing health and nutrition services at limited additional cost. Failure to scale up has severe personal and social consequences. Children at elevated risk for compromised development due to stunting and poverty are likely to forgo about a quarter of average adult income per year, and the cost of inaction to gross domestic product can be double what some countries currently spend on health. Services and interventions to support early childhood development are essential to realising the vision of the Sustainable Development Goals. PMID:27717610

  19. Developing workshop module of realistic mathematics education: Follow-up workshop

    Science.gov (United States)

    Palupi, E. L. W.; Khabibah, S.

    2018-01-01

    Realistic Mathematics Education (RME) is a learning approach which fits the aim of the curriculum. The success of RME in teaching mathematics concepts, triggering students’ interest in mathematics and teaching high order thinking skills to the students will make teachers start to learn RME. Hence, RME workshop is often offered and done. This study applied development model proposed by Plomp. Based on the study by RME team, there are three kinds of RME workshop: start-up workshop, follow-up workshop, and quality boost. However, there is no standardized or validated module which is used in that workshops. This study aims to develop a module of RME follow-up workshop which is valid and can be used. Plopm’s developmental model includes materials analysis, design, realization, implementation, and evaluation. Based on the validation, the developed module is valid. While field test shows that the module can be used effectively.

  20. Fluvio geomorphic set-up of Noctis Fossae in Noctis Labyrinthus of Syria-Planum Provenance, Mars

    Science.gov (United States)

    Chavan, A. A.; Bhandari, S.

    2017-12-01

    The modern era of planetary exploration has revealed fluvial or fluvial like landforms on the extraterrestrial surfaces of planets and moons of our solar system. This has posed as interesting challenges for advancing our fundamental understanding of fluvial processes and their associated landforms on the planetary surfaces especially on Mars. It has been recognized through earlier studies that the channels and valleys are extensively dissected on Mars. The Valleys are low lying, elongate troughs surrounded by elevated topography. Moreover, valley networks on Mars are the most noticeable features attesting that different geological processes and possibly climatic conditions prevailed in the past and played a vital role in formulating the Martian topography. Channel incisions which are a domino effect both tectonic and surface runoff and groundwater sapping. The components of surface runoff have been deciphered with the help of morphometric exercises. Further, the geomorphological studies of these landforms are critical in understanding the regional tectonics. The present work is an assessment of Fluvio geomorphic set-up of Noctis Fossae in Noctis Labyrinthus of Syria-Planum Provenance, Mars. This study focuses on the fluvio geomorphology of the southern highlands (00 to 400S to 850-1200W) to determine how these features were formed, which process formed these valleys and includes the probable causes resulting into the development of the topography. Keywords: Noctis Fossae; Noctis Labyrinthus; Syria Planum; Mars

  1. Technical development on burn-up credit for spent LWR fuels

    International Nuclear Information System (INIS)

    Nakahara, Yoshinori; Suyama, Kenya; Suzaki, Takenori

    2000-10-01

    Technical development on burn-up credit for spent LWR fuels had been performed at JAERI since 1990 under the contract with Science and Technology Agency of Japan entitled 'Technical Development on Criticality Safety Management for Spent LWR Fuels'. Main purposes of this work are to obtain the experimental data on criticality properties and isotopic compositions of spent LWR fuels and to verify burn-up and criticality calculation codes. In this work three major experiments of exponential experiments for spent fuel assemblies to obtain criticality data, non-destructive gamma-ray measurement of spent fuel rods for evaluating axial burn-up profiles, and destructive analyses of spent fuel samples for determining precise burn-up and isotopic compositions were carried out. The measured data obtained were used for validating calculation codes as well as an examination of criticality safety analyses. Details of the work are described in this report. (author)

  2. Technical development on burn-up credit for spent LWR fuels

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Yoshinori; Suyama, Kenya; Suzaki, Takenori [eds.] [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2000-10-01

    Technical development on burn-up credit for spent LWR fuels had been performed at JAERI since 1990 under the contract with Science and Technology Agency of Japan entitled 'Technical Development on Criticality Safety Management for Spent LWR Fuels'. Main purposes of this work are to obtain the experimental data on criticality properties and isotopic compositions of spent LWR fuels and to verify burn-up and criticality calculation codes. In this work three major experiments of exponential experiments for spent fuel assemblies to obtain criticality data, non-destructive gamma-ray measurement of spent fuel rods for evaluating axial burn-up profiles, and destructive analyses of spent fuel samples for determining precise burn-up and isotopic compositions were carried out. The measured data obtained were used for validating calculation codes as well as an examination of criticality safety analyses. Details of the work are described in this report. (author)

  3. Challenges in interprofessional collaboration: experiences of care providers and policymakers in a newly set-up Dutch assault centre.

    Science.gov (United States)

    Zijlstra, Elza; Lo Fo Wong, Sylvie; Teerling, Anne; Hutschemaekers, Giel; Lagro-Janssen, Antoine

    2018-03-01

    Sexual and family violence are problems that affect many women and men, and the negative health consequences of violence are numerous. As adequate acute interprofessional care can prevent negative health consequences and improve forensic medical examination, a Centre for Sexual and Family Violence was set up. We aimed to improve our understanding of the challenges in interprofessional collaboration in a newly set-up centre for sexual and family violence. We conducted a qualitative study with semi-structured interviews about the experiences with interprofessional collaboration of 16 stakeholders involved in the Centre for Sexual and Family Violence Nijmegen. Participants were selected by purposive sampling. Participants found that the interprofessional collaboration had improved communication and competences. However, there were challenges too. Firstly, the interprofessional collaboration had brought parties closer together, but the collaboration also forced professionals to strongly define their boundaries. Mutual trust and understanding needed to be built up. Secondly, a balance had to be struck between pursuing the shared vision - which was to improve quality of care for victims - and giving space to organizations' and professionals' own interest. Thirdly, care for victims of sexual and family violence could be demanding on healthcare providers in an emotional sense, which might jeopardize professional's initial motivation for joining the Centre for Sexual and Family Violence Nijmegen. The interprofessional collaboration in an assault centre improves quality of care for victims, but there are also challenges. The tasks of an assault centre are to create opportunities to discuss professional roles and professional interests, to build up good interpersonal relations in which trust and understanding can grow, to formulate a strong and shared victim-centred vision and to support care providers with training, feedback and supervision. © 2017 Nordic College of Caring

  4. Assessment of pollutants in manzala lake using gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Abdel-Haleem, A.S.; Zaghloul, R.; El-Abbady, W.H.; Hassan, A.M.

    1996-01-01

    Multielemental analysis of water samples taken from the area of manzala lake in the east-north of river Nile delta of egypt, has been performed. Prompt gamma neutron activation analysis (PGNAA) technique is applied to determine the elemental concentrations. The samples have been irradiated by means of (PGNAA) facility using a Cf 252 isotopic neutron source with a total flux of 1.5 x 10 5 n cm 2 s -1 for 300 min irradiation time. The evaluation of Cd, Gd, Sm, Pb, Zn, Co and Hg as trace elements in these samples is reported. 1 fig., 2 tabs

  5. Set-up errors analyses in IMRT treatments for nasopharyngeal carcinoma to evaluate time trends, PTV and PRV margins

    Energy Technology Data Exchange (ETDEWEB)

    Mongioj, Valeria (Dept. of Medical Physics, Fondazione IRCCS Istituto Nazionale Tumori, Milan (Italy)), e-mail: valeria.mongioj@istitutotumori.mi.it; Orlandi, Ester (Dept. of Radiotherapy, Fondazione IRCCS Istituto Nazionale Tumori, Milan (Italy)); Palazzi, Mauro (Dept. of Radiotherapy, A.O. Niguarda Ca' Granda, Milan (Italy)) (and others)

    2011-01-15

    Introduction. The aims of this study were to analyze the systematic and random interfractional set-up errors during Intensity Modulated Radiation Therapy (IMRT) in 20 consecutive nasopharyngeal carcinoma (NPC) patients by means of Electronic Portal Images Device (EPID), to define appropriate Planning Target Volume (PTV) and Planning Risk Volume (PRV) margins, as well as to investigate set-up displacement trend as a function of time during fractionated RT course. Material and methods. Before EPID clinical implementation, an anthropomorphic phantom was shifted intentionally 5 mm to all directions and the EPIs were compared with the digitally reconstructed radiographs (DRRs) to test the system's capability to recognize displacements observed in clinical studies. Then, 578 clinical images were analyzed with a mean of 29 images for each patient. Results. Phantom data showed that the system was able to correct shifts with an accuracy of 1 mm. As regards clinical data, the estimated population systematic errors were 1.3 mm for left-right (L-R), 1 mm for superior-inferior (S-I) and 1.1 mm for anterior-posterior (A-P) directions, respectively. Population random errors were 1.3 mm, 1.5 mm and 1.3 mm for L-R, S-I and A-P directions, respectively. PTV margin was at least 3.4, 3 and 3.2 mm for L-R, S-I and A-P direction, respectively. PRV margins for brainstem and spinal cord were 2.3, 2 and 2.1 mm and 3.8, 3.5 and 3.2 mm for L-R, A-P and S-I directions, respectively. Set-up error displacements showed no significant changes as the therapy progressed (p>0.05), although displacements >3 mm were found more frequently when severe weight loss or tumor nodal shrinkage occurred. Discussion. These results enable us to choose margins that guarantee with sufficient accuracy the coverage of PTVs and organs at risk sparing. Collected data confirmed the need for a strict check of patient position reproducibility in case of anatomical changes

  6. Light Up the Word update 2001-2002 : solid state lighting for human development

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, K.; Irvine-Halliday, D. [Calgary Univ., AB (Canada). Dept. of Electrical and Computer Engineering, Light Up the World Foundation; Craine, S. [Curtin Univ. of Technology (Australia)]|[Calgary Univ., AB (Canada). Dept. of Electrical and Computer Engineering, Light Up the World Foundation; Stone, R. [Fernbank Electronic Systems Ltd., Stittsville, ON (Canada)

    2002-07-01

    Light Up the World Foundation (LUTW) is a humanitarian organization founded in 1997 to bring safe, healthy, reliable, environmentally sound and affordable home lighting to developing countries. LUTW is a world leader in using solid state lighting (SSL) technologies to improve the quality of life for underprivileged people living in villages with little realistic prospect for affordable electrification. SSL technology uses white light-emitting diodes (LEDs) to provide lighting at low power consumption, often from batteries that get recharged by solar panels or other renewable energy sources. LUTW is active in more than 12 countries and has set the standards to raising the quality of SSL as a community development tool around the world. This report described how LUTW developed its market for SSL and the basic component for forging a relationship between industrial and social entrepreneurship. The international efforts to reduce greenhouse gas (GHG) emissions under climate change mitigation mechanisms such as carbon reduction emission credits, allows LUTW to obtain additional revenues to help sustain its projects. This is because the amount of fossil fuel and GHG reductions from SSL systems can be readily quantified. 4 refs., 1 tab., 1 fig.

  7. Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging.

    Science.gov (United States)

    Verellen, Dirk; Soete, Guy; Linthout, Nadine; Van Acker, Swana; De Roover, Patsy; Vinh-Hung, Vincent; Van de Steene, Jan; Storme, Guy

    2003-04-01

    The aim of this study is to investigate the positional accuracy of a prototype X-ray imaging tool in combination with a real-time infrared tracking device allowing automated patient set-up in three dimensions. A prototype X-ray imaging tool has been integrated with a commercially released real-time infrared tracking device. The system, consisting of two X-ray tubes mounted to the ceiling and a centrally located amorphous silicon detector has been developed for automated patient positioning from outside the treatment room prior to treatment. Two major functions are supported: (a) automated fusion of the actual treatment images with digitally reconstructed radiographs (DRRs) representing the desired position; (b) matching of implanted radio opaque markers. Measurements of known translational (up to 30.0mm) and rotational (up to 4.0 degrees ) set-up errors in three dimensions as well as hidden target tests have been performed on anthropomorphic phantoms. The system's accuracy can be represented with the mean three-dimensional displacement vector, which yielded 0.6mm (with an overall SD of 0.9mm) for the fusion of DRRs and X-ray images. Average deviations between known translational errors and calculations varied from -0.3 to 0.6mm with a standard deviation in the range of 0.6-1.2mm. The marker matching algorithm yielded a three-dimensional uncertainty of 0.3mm (overall SD: 0.4mm), with averages ranging from 0.0 to 0.3mm and a standard deviation in the range between 0.3 and 0.4mm. The stereoscopic X-ray imaging device integrated with the real-time infrared tracking device represents a positioning tool allowing for the geometrical accuracy that is required for conformal radiation therapy of abdominal and pelvic lesions, within an acceptable time-frame.

  8. Setting Up Simulations of Failure Scenarios for a Crab Cavity in the Nominal LHC

    CERN Document Server

    Yee, B

    2010-01-01

    The crab cavity (CC) represents a possible solution for the problem of the reduction of the luminosity due to a crossing angle. The CC apply a transversal kick on the beam particles that varies with the longitudinal position along the bunch in order to produce an effective head-head collision and to increase the geometry luminosity. For that reason the BE-ABP group at CERN has been performing studies for the implementation of the CC in the LHC. Because machine protection is a critical element of LHC operation, it is essential to study the failure scenarios of the superconducting crab cavity and the possible resulting damage impact and well as to find possible mitigation measures. For this purpose we set up simulation tools to model CC failures in the nominal LHC.

  9. Technical note: An experimental set-up to measure latent and sensible heat fluxes from (artificial plant leaves

    Directory of Open Access Journals (Sweden)

    S. J. Schymanski

    2017-07-01

    Full Text Available Leaf transpiration and energy exchange are coupled processes that operate at small scales yet exert a significant influence on the terrestrial hydrological cycle and climate. Surprisingly, experimental capabilities required to quantify the energy–transpiration coupling at the leaf scale are lacking, challenging our ability to test basic questions of importance for resolving large-scale processes. The present study describes an experimental set-up for the simultaneous observation of transpiration rates and all leaf energy balance components under controlled conditions, using an insulated closed loop miniature wind tunnel and artificial leaves with pre-defined and constant diffusive conductance for water vapour. A range of tests documents the above capabilities of the experimental set-up and points to potential improvements. The tests reveal a conceptual flaw in the assumption that leaf temperature can be characterized by a single value, suggesting that even for thin, planar leaves, a temperature gradient between the irradiated and shaded or transpiring and non-transpiring leaf side can lead to bias when using observed leaf temperatures and fluxes to deduce effective conductances to sensible heat or water vapour transfer. However, comparison of experimental results with an explicit leaf energy balance model revealed only minor effects on simulated leaf energy exchange rates by the neglect of cross-sectional leaf temperature gradients, lending experimental support to our current understanding of leaf gas and energy exchange processes.

  10. Investing in the foundation of sustainable development: pathways to scale up for early childhood development.

    Science.gov (United States)

    Richter, Linda M; Daelmans, Bernadette; Lombardi, Joan; Heymann, Jody; Boo, Florencia Lopez; Behrman, Jere R; Lu, Chunling; Lucas, Jane E; Perez-Escamilla, Rafael; Dua, Tarun; Bhutta, Zulfiqar A; Stenberg, Karin; Gertler, Paul; Darmstadt, Gary L

    2017-01-07

    Building on long-term benefits of early intervention (Paper 2 of this Series) and increasing commitment to early childhood development (Paper 1 of this Series), scaled up support for the youngest children is essential to improving health, human capital, and wellbeing across the life course. In this third paper, new analyses show that the burden of poor development is higher than estimated, taking into account additional risk factors. National programmes are needed. Greater political prioritisation is core to scale-up, as are policies that afford families time and financial resources to provide nurturing care for young children. Effective and feasible programmes to support early child development are now available. All sectors, particularly education, and social and child protection, must play a role to meet the holistic needs of young children. However, health provides a critical starting point for scaling up, given its reach to pregnant women, families, and young children. Starting at conception, interventions to promote nurturing care can feasibly build on existing health and nutrition services at limited additional cost. Failure to scale up has severe personal and social consequences. Children at elevated risk for compromised development due to stunting and poverty are likely to forgo about a quarter of average adult income per year, and the cost of inaction to gross domestic product can be double what some countries currently spend on health. Services and interventions to support early childhood development are essential to realising the vision of the Sustainable Development Goals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. A new X-ray absorption experimental set-up dedicated to DeNOx catalysis

    International Nuclear Information System (INIS)

    Revel, R.; Bazin, D.; Seigneurin, A.; Barthe, P.; Dubuisson, J.M.; Decamps, T.; Sonneville, H.; Poher, J.J.; Maire, F.; Lefrancois, P.

    1999-01-01

    In this paper, we present a complete in situ X-ray absorption reaction cell that simulates DeNO x experimental conditions. In this device, the sample is placed at high temperature under the flow of a complex mixture of reactive gases (NO, C 3 H 6 , O 2 , N 2 ). Particular attention has been paid to the material and design of the sample holders in order to avoid preferential gas circulation and thus ensure a true diffusion of the reactive gases on the catalyst. Moreover, precise control of the gas flow is maintained by means of mass flow controllers, and the safety of the set-up is assured by CO, CO 2 and NO detectors directly relayed to an electronic device, which is itself linked to the various mass flow controllers. Finally, the possibilities of this device are illustrated through the in situ XANES study of a Cu-ZSM-5 catalytic system

  12. Set up and application of an underwater Α-ray spectrometer for radioactivity measurements

    Directory of Open Access Journals (Sweden)

    C. TSABARIS

    2005-06-01

    Full Text Available The set up and control of an underwater measuring instrument for radioactivity pollution in the marine environment is described. The detection system is based on a NaI scintillator (RADAM III with modifications for use in the marine environment with on-line measurements. The system is simple, has low power consumption and is stable for long-term monitoring (10 months. Before its deployment, the sensor was calibrated in the laboratory in a tank full of water to reproduce the marine environment. The calibrations were performed, by detecting the 661keV and 1461 keV gamma rays of known activity liquid sources 137 Cs and 40 K, respectively. The measured spectra in the laboratory were compared with spectra from a similar detector as acquired in the field. The analysis of the parallel measurement gave satisfactory agreement for the concentration of the potassium (40 K, as calculated from the salinity in the seawater, thus enabling the system for quantitative measurement of the seawater radioactivity.

  13. Setting up and functioning of an Emergency Medicine Department: Lessons learned from a preliminary study

    Directory of Open Access Journals (Sweden)

    K Asish

    2016-01-01

    Full Text Available Background and Aims: Tertiary care teaching hospitals remain referral centres for victims of trauma and mass casualty. Often specialists from various disciplines manage these crowded casualty areas. These age old casualty areas are being replaced, throughout the country by Emergency Medicine Departments (EMDs, presumed to be better planned to confront a crisis. We aimed to gather basic data contributive in setting up of an EMD at a tertiary care teaching hospital from the lessons learned from functioning existent systems. Methods: This is primarily a questionnaire-based descriptive study at tertiary care referral centres across the country, which was purposively selected.The study models included one from a hospital without designated EMD and the other four from hospitals with established EMDs. Direct observation and focus group meetings with experienced informants at these hospitals contributed to the data. In the absence of a validated hospital preparedness assessment scale, comparison was done with regard to quantitative, qualitative and corroborative parameters using descriptive analysis. Results: The EMDs at best practice models were headed by specialist in Emergency Medicine assisted by organised staff, had protocols for managing mass casualty incident (MCI, separate trauma teams, ergonomic use of infrastructure and public education programmes. In this regard, these hospitals seemed well organised to manage MCIs and disasters. Conclusion: The observation may provide a preliminary data useful in setting up an EMD. In the absence of published Indian literature, this may facilitate further research in this direction. Anaesthesiologists, presently an approved Faculty in Emergency Medicine training can provide creative input with regard to its initial organisation and functioning, thus widening our horizons in a country where there is a severe dearth of trained emergency physicians.

  14. CAMAC - supported electronic set-up for the determination of the capture cross section of the reaction 1H(n,d)γ

    International Nuclear Information System (INIS)

    Hutsch, J.; Moeller, K.; Moesner, J.; Neubert, W.; Pilz, W.; Schmidt, G.; Stiehler, T.; Kudin, L.G.; Spiridenkov, E.M.; Volkov, S.S.

    1984-08-01

    After a brief description of the physical problem the experimental apparatus and the electronic set-up for the investigation of the capture reaction 1 H(n,d)γ at E/sub n/ = 25 MeV are described. (author)

  15. Technological parameter and experimental set-up influences on latch-up triggering level in bulk CMOS device

    International Nuclear Information System (INIS)

    Dubuc, J.P.; Azais, B.; Murcia, M. de

    1994-01-01

    This paper deals with experimental and simulation results on latch-up triggered by an electrical or X-rays pulse in CMOS/bulk devices. Test condition influences as well as the great importance of process parameters on latch-up immunity are emphasized. (author). 10 refs., 19 figs., 1 tab

  16. First results with the experimental set-up at a Bugey reactor: neutrino oscillations, search of axions

    International Nuclear Information System (INIS)

    Hoummada, A.

    1982-07-01

    This work presents an experimental set-up at the Bugey PWR reactor to put into evidence neutrino oscillations. The first part describes a neutrino detector specially designed for the investigation of neutrino oscillations at two distances (13.50 m and 19 m) under the core of the reactor. Preliminary analysis are presented. The second part reports a search for axions, using the neutrino detector well-shielded volume. Created in competition with electro magnetic transitions, axion should be produced in abondance in the reactor core. This experiment excludes the existence of the axion of the standard model [fr

  17. Goal Setting Theory: What It Implies for Strategic Human Resource Development

    OpenAIRE

    AVCI, Ömer

    2016-01-01

    Among numerous motivational theories, goal setting theory particularly can serve strategic human resource development practices. The goal-setting theory suggests that organizational goals have to be communicated clearly and the goals need to be specific enough. Another feature of goal-setting is that they need not be too easy or perceived to be impossible to fulfill. SHRD personnel should keep in mind that some employees prefer to work individually toward fulfilling a goal, while others prefe...

  18. How to Develop Electrochemistry SETS-Based Interactive E-Book?

    Science.gov (United States)

    Munawwarah, M.; Anwar, S.; Sunarya, Y.

    2017-09-01

    This study aims to develop SETS-based interactive e-book teaching material through 4S TMD methode. The research methode in this study is the Development Research (RD) Richey and Klein that consists of design, phase, and evaluation. The design step was to analyze and plan the types of teaching materials instructional developed. There are 12 indicators from 3 standard competences that produced in selection step based new curriculum, the compatibility subject matter and indicators, and the relations between value and subject matter. Structuring steps yield concept map, macro structure, and multiple representation that were arranged to be first draft of teaching material that was used for develop the instruments for characterization step. Chatacterization test have been done to students in 12nd grades with 68 texts. Characterization results indicated that there were some texts included to difficult text. Difficult texts have been reduced with the ways back to qualitative steps and particulation. The second draft of teaching material was arranged based the results of didactic reduction of difficult texts. This draft was used for arranged interactive e-book. The characteristics of this SETS-based interactive e-book that developed were mention about the connection between science with environment, technology, and society. This interactive e-book consists of animation, task, and quizes that taken the interaction of students directly.

  19. Workstations as consoles for the CERN-PS complex, setting-up the environment

    International Nuclear Information System (INIS)

    Antonsanti, P.; Arruat, M.; Bouche, J.M.; Cons, L.; Deloose, Y.; Di Maio, F.

    1992-01-01

    Within the framework of the rejuvenation project of the CERN control systems, commercial workstations have to replace existing home-designed operator consoles. RISC-based workstations with UNIX, X-window TM and OSF/Motif TM have been introduced for the control of the PS complex. The first versions of general functionalities like synoptic display, program selection and control panels have been implemented and the first large scale application has been realized. This paper describes the different components of the workstation environment for the implementation of the applications. The focus is on the set of tools which have been used, developed or integrated, and on how we plan to make them evolve. (author)

  20. Agile metodologies use for software development in Slovenian start-ups

    OpenAIRE

    Kašnik, Matic

    2014-01-01

    The thesis presents and describes the use of agile methodologies which are being used by Slovenian tech start-up companies. It describes the basic features, advantages and disadvantages of various agile methodologies such as Scrum, extreme programming, lean start-up and method Kanban. We made a review of the most used agile methodologies in Slovenian technology start-up companies. In particular, we focus on variety of tools, technics and approaches used by the development teams and where do t...

  1. Swell-generated Set-up and Infragravity Wave Propagation Over a Fringing Coral Reef: Implications for Wave-driven Inundation of Atoll Islands

    Science.gov (United States)

    Cheriton, O. M.; Storlazzi, C. D.; Rosenberger, K. J.; Quataert, E.; van Dongeren, A.

    2014-12-01

    The Republic of the Marshall Islands is comprised of 1156 islands on 29 low-lying atolls with a mean elevation of 2 m that are susceptible to sea-level rise and often subjected to overwash during large wave events. A 6-month deployment of wave and tide gauges across two shore-normal sections of north-facing coral reef on the Roi-Namur Island on Kwajalein Atoll was conducted during 2013-2014 to quantify wave dynamics and wave-driven water levels on the fringing coral reef. Wave heights and periods on the reef flat were strongly correlated to the water levels. On the fore reef, the majority of wave energy was concentrated in the incident band (5-25 s); due to breaking at the reef crest, however, the wave energy over the reef flat was dominated by infragravity-band (25-250 s) motions. Two large wave events with heights of 6-8 m at 15 s over the fore reef were observed. During these events, infragravity-band wave heights exceeded the incident band wave heights and approximately 1.0 m of set-up was established over the innermost reef flat. This set-up enabled the propagation of large waves across the reef flat, reaching maximum heights of nearly 2 m on the innermost reef flat adjacent to the toe of the beach. XBEACH models of the instrument transects were able to replicate the incident waves, infragravity waves, and wave-driven set-up across the reef when the hydrodynamic roughness of the reef was correctly parameterized. These events led to more than 3 m of wave-driven run-up and inundation of the island that drove substantial morphological change to the beach face.

  2. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  3. Determination and evaluation of intra fractional and set-up changes during radiotherapy to the cervical carcinoma using cone beam computed tomography

    International Nuclear Information System (INIS)

    Pathak, Pankaj; Kumar, Rajesh; Birbiya, Narendra; Mishra, Praveen Kumar; Singh, Manisha; Mishra, Pankaj Kumar

    2017-01-01

    To confirm the accuracy of the location of the Fudicial markings in relation to the actual isocentre of the irradiated volume due to Intra-fractional and Set-Up changes in Cancer Cervix with the help of Cone Beam computed Tomography (CBCT)

  4. 'Scaling-up is a craft not a science': Catalysing scale-up of health innovations in Ethiopia, India and Nigeria.

    Science.gov (United States)

    Spicer, Neil; Bhattacharya, Dipankar; Dimka, Ritgak; Fanta, Feleke; Mangham-Jefferies, Lindsay; Schellenberg, Joanna; Tamire-Woldemariam, Addis; Walt, Gill; Wickremasinghe, Deepthi

    2014-11-01

    Donors and other development partners commonly introduce innovative practices and technologies to improve health in low and middle income countries. Yet many innovations that are effective in improving health and survival are slow to be translated into policy and implemented at scale. Understanding the factors influencing scale-up is important. We conducted a qualitative study involving 150 semi-structured interviews with government, development partners, civil society organisations and externally funded implementers, professional associations and academic institutions in 2012/13 to explore scale-up of innovative interventions targeting mothers and newborns in Ethiopia, the Indian state of Uttar Pradesh and the six states of northeast Nigeria, which are settings with high burdens of maternal and neonatal mortality. Interviews were analysed using a common analytic framework developed for cross-country comparison and themes were coded using Nvivo. We found that programme implementers across the three settings require multiple steps to catalyse scale-up. Advocating for government to adopt and finance health innovations requires: designing scalable innovations; embedding scale-up in programme design and allocating time and resources; building implementer capacity to catalyse scale-up; adopting effective approaches to advocacy; presenting strong evidence to support government decision making; involving government in programme design; invoking policy champions and networks; strengthening harmonisation among external programmes; aligning innovations with health systems and priorities. Other steps include: supporting government to develop policies and programmes and strengthening health systems and staff; promoting community uptake by involving media, community leaders, mobilisation teams and role models. We conclude that scale-up has no magic bullet solution - implementers must embrace multiple activities, and require substantial support from donors and governments in

  5. SET UP OF THE NEW AUTOMATIC HYDROMETEOROLOGICAL NETWORK IN HUNGARY

    Directory of Open Access Journals (Sweden)

    J. NAGy

    2013-03-01

    Full Text Available The Hungarian Meteorological Service (OMSZ and General Directorate of Water Management (OVF in Hungary run conventional precipitation measurement networks consisting of at least 1000 stations. OMSZ automated its synoptic and climatological network in 90’s and now more than 100 automatic stations give data every 1-10 minutes via GPRS channel. In 2007 the experts from both institutions determined the requirements of a common network. The predecessor in title of OVF is general Directorate for Water and Environment gave a project proposal in 2008 for establishment of a new hydrometeorological network based on common aims for meteorology and hydrology. The new hydrometeorological network was set up in 2012 financed by KEOP project. This network has got 141 weighing precipitation gauges, 118 temperature - humidity sensors and 25 soil moisture and soil temperature instruments. Near by Tisza-Lake two wind sensors have been installed. The network is operated by OMSZ and OVF together. OVF and its institutions maintain the stations itself and support the electricity. OMSZ operates data collection and transmission, maintaines and calibrates the sensors. Using precipitation data of enhanced network the radar precipitation field quality may be more precise, which are input of run-off model. Thereby the time allowance may be increased in flood-control events. Based on soil moisture and temperature water balance in soil may be modelled and forecast can be produced in different conditions. It is very important task in drought and inland water conditions. Considering OMSZ investment project in which new Doppler dual polarisation radar and 14 disdrometers will be installed, the precipitation estimation may be improved since 2015.

  6. Sign up to Safety: developing a safety improvement plan.

    Science.gov (United States)

    Dight, Carol; Peters, Hayley

    2015-04-01

    The Sign up to Safety (SutS) programme was launched in June 2014 by health secretary Jeremy Hunt. It focuses on listening to patients, carers and staff, learning from what they say when things go wrong, and then taking action to improve patient safety. The programme aims to make the NHS the safest healthcare system in the world by creating a culture devoted to continuous learning and improvement (NHS England 2014). Musgrove Park Hospital, part of Taunton and Somerset NHS Foundation Trust, was one of 12 NHS organisations that signed up to the SutS programme, making public its commitment to the national pledges to be 'open and transparent' and to develop a safety improvement plan. This paper describes the development of the strategy.

  7. Decree N0 81-978 of 29 October 1981 setting up a Higher Council for Nuclear Safety

    International Nuclear Information System (INIS)

    1981-01-01

    This Decree amends the Decree of 13 March 1973 setting up a High Council for Nuclear Safety and a Central Service for the Safety of Nuclear Installations. The High Council, which is attached to the Ministry of industry, is competent to advise on all questions involving the safety of nuclear installations. Henceforth, the National Assembly, the Senate and the regional or general Councils concerned may request the Minister to submit for consideration by the High Council all important matters within its competence. (NEA) [fr

  8. Development of the 3-SET 4P questionnaire for evaluating former ICU patients' physical and psychosocial problems over time: a pilot study.

    Science.gov (United States)

    Akerman, Eva; Fridlund, Bengt; Ersson, Anders; Granberg-Axéll, Anetth

    2009-04-01

    Current studies reveal a lack of consensus for the evaluation of physical and psychosocial problems after ICU stay and their changes over time. The aim was to develop and evaluate the validity and reliability of a questionnaire for assessing physical and psychosocial problems over time for patients following ICU recovery. Thirty-nine patients completed the questionnaire, 17 were retested. The questionnaire was constructed in three sets: physical problems, psychosocial problems and follow-up care. Face and content validity were tested by nurses, researchers and patients. The questionnaire showed good construct validity in all three sets and had strong factor loadings (explained variance >70%, factor loadings >0.5) for all three sets. There was good concurrent validity compared with the SF 12 (r(s)>0.5). Internal consistency was shown to be reliable (Cronbach's alpha 0.70-0.85). Stability reliability on retesting was good for the physical and psychosocial sets (r(s)>0.5). The 3-set 4P questionnaire was a first step in developing an instrument for assessment of former ICU patients' problems over time. The sample size was small and thus, further studies are needed to confirm these findings.

  9. Records for radioactive waste management up to repository closure: Managing the primary level information (PLI) set

    International Nuclear Information System (INIS)

    2004-07-01

    , are generated, identified, reviewed and actively managed during pre-closure phases so that they are available and usable at the appropriate time. This publication addresses the establishment and management of the PLI set up to the point of closure of a repository. Specifically, it (1) describes the importance of establishing a coordinated, integrated and well-managed PLI set, (2) provides a basic overview of the components of a PLI set, and (3) provides general guidance on the management of and responsibility for the PLI set

  10. SU-C-204-06: Surface Imaging for the Set-Up of Proton Post-Mastectomy Chestwall Irradiation: Gated Images Vs Non Gated Images

    Energy Technology Data Exchange (ETDEWEB)

    Batin, E; Depauw, N; MacDonald, S; Lu, H [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: Historically, the set-up for proton post-mastectomy chestwall irradiation at our institution started with positioning the patient using tattoos and lasers. One or more rounds of orthogonal X-rays at gantry 0° and beamline X-ray at treatment gantry angle were then taken to finalize the set-up position. As chestwall targets are shallow and superficial, surface imaging is a promising tool for set-up and needs to be investigated Methods: The orthogonal imaging was entirely replaced by AlignRT™ (ART) images. The beamline X-Ray image is kept as a confirmation, based primarily on three opaque markers placed on skin surface instead of bony anatomy. In the first phase of the process, ART gated images were used to set-up the patient and the same specific point of the breathing curve was used every day. The moves (translations and rotations) computed for each point of the breathing curve during the first five fractions were analyzed for ten patients. During a second phase of the study, ART gated images were replaced by ART non-gated images combined with real-time monitoring. In both cases, ART images were acquired just before treatment to access the patient position compare to the non-gated CT. Results: The average difference between the maximum move and the minimum move depending on the chosen breathing curve point was less than 1.7 mm for all translations and less than 0.7° for all rotations. The average position discrepancy over the course of treatment obtained by ART non gated images combined to real-time monitoring taken before treatment to the planning CT were smaller than the average position discrepancy obtained using ART gated images. The X-Ray validation images show similar results with both ART imaging process. Conclusion: The use of ART non gated images combined with real time imaging allows positioning post-mastectomy chestwall patients in less than 3 mm / 1°.

  11. SU-C-204-06: Surface Imaging for the Set-Up of Proton Post-Mastectomy Chestwall Irradiation: Gated Images Vs Non Gated Images

    International Nuclear Information System (INIS)

    Batin, E; Depauw, N; MacDonald, S; Lu, H

    2015-01-01

    Purpose: Historically, the set-up for proton post-mastectomy chestwall irradiation at our institution started with positioning the patient using tattoos and lasers. One or more rounds of orthogonal X-rays at gantry 0° and beamline X-ray at treatment gantry angle were then taken to finalize the set-up position. As chestwall targets are shallow and superficial, surface imaging is a promising tool for set-up and needs to be investigated Methods: The orthogonal imaging was entirely replaced by AlignRT™ (ART) images. The beamline X-Ray image is kept as a confirmation, based primarily on three opaque markers placed on skin surface instead of bony anatomy. In the first phase of the process, ART gated images were used to set-up the patient and the same specific point of the breathing curve was used every day. The moves (translations and rotations) computed for each point of the breathing curve during the first five fractions were analyzed for ten patients. During a second phase of the study, ART gated images were replaced by ART non-gated images combined with real-time monitoring. In both cases, ART images were acquired just before treatment to access the patient position compare to the non-gated CT. Results: The average difference between the maximum move and the minimum move depending on the chosen breathing curve point was less than 1.7 mm for all translations and less than 0.7° for all rotations. The average position discrepancy over the course of treatment obtained by ART non gated images combined to real-time monitoring taken before treatment to the planning CT were smaller than the average position discrepancy obtained using ART gated images. The X-Ray validation images show similar results with both ART imaging process. Conclusion: The use of ART non gated images combined with real time imaging allows positioning post-mastectomy chestwall patients in less than 3 mm / 1°

  12. Identifying Early Childhood Personality Dimensions Using the California Child Q-Set and Prospective Associations With Behavioral and Psychosocial Development.

    Science.gov (United States)

    Wilson, Sylia; Schalet, Benjamin D; Hicks, Brian M; Zucker, Robert A

    2013-08-01

    The present study used an empirical, "bottom-up" approach to delineate the structure of the California Child Q-Set (CCQ), a comprehensive set of personality descriptors, in a sample of 373 preschool-aged children. This approach yielded two broad trait dimensions, Adaptive Socialization (emotional stability, compliance, intelligence) and Anxious Inhibition (emotional/behavioral introversion). Results demonstrate the value of using empirical derivation to investigate the structure of personality in young children, speak to the importance of early-evident personality traits for adaptive development, and are consistent with a growing body of evidence indicating that personality structure in young children is similar, but not identical to, that in adults, suggesting a model of broad personality dimensions in childhood that evolve into narrower traits in adulthood.

  13. Empowering community settings: agents of individual development, community betterment, and positive social change.

    Science.gov (United States)

    Maton, Kenneth I

    2008-03-01

    The pathways and processes through which empowering community settings influence their members, the surrounding community and the larger society are examined. To generate the proposed pathways and processes, a broad range of studies of community settings were reviewed, in the domains of adult well-being, positive youth development, locality development, and social change. A set of organizational characteristics and associated processes leading to member empowerment across domains were identified, as well as three pathways through which empowering settings in each domain contribute to community betterment and positive social change. The paper concludes with an examination of the ways that community psychology and allied disciplines can help increase the number and range of empowering settings, and enhance the community and societal impact of existing ones.

  14. Physical aspects of an electronuclear set-up on the basis of the subcritical zone of the IBR-30 reactor and the 660 MeV proton phasotron

    International Nuclear Information System (INIS)

    Barashenkov, V.S.; Pogodaev, G.N.; Polanski, A.; Popov, Yu.P.; Puzynin, I.V.; Sisakyan, A.N.; Sosnin, A.N.

    1998-01-01

    Mathematical modeling and thermal flux estimations show that a combination of installations available at present at JINR - the plutonium reactor IBR-30 and the 660 MeV proton phasotron with the current of the extracted beam 0.25 mkA, i.e. 10% of its average value, - allows one to construct an air-cooled electronuclear set-up with the multiplication coefficient K eff ≅ 0.94, the neutron yield N tot ≅ 10 14 - 10 15 and the heat generation about to 10 kW. This set-up will demonstrate a possibility to construct subcritical transmutation-power generating electronuclear systems safe and stable in operation and applicable for utilization of weapon grade and technical plutonium. Kinetics of the electronuclear system will be investigated, in particular, fluctuations of the value of K eff for various parameters of the proton beam. Cross sections of nuclear reactions which are important for the estimations of an efficiency of various conditions of the nuclear waste transmutation and the neutron fluxes together with the heat distributions inside and outside the plutonium core will be measured. A comparison of these data with theoretical calculations allows one to check up and to develop significantly the methods of mathematical modeling of electronuclear systems. We suppose also to estimate the possibilities of ARC-method for the burning of radioactive wastes and to study the influence of various reflectors and multipartitioning of the core which increases the neutron yield. (author)

  15. Reconstruction of gene regulatory modules from RNA silencing of IFN-α modulators: experimental set-up and inference method.

    Science.gov (United States)

    Grassi, Angela; Di Camillo, Barbara; Ciccarese, Francesco; Agnusdei, Valentina; Zanovello, Paola; Amadori, Alberto; Finesso, Lorenzo; Indraccolo, Stefano; Toffolo, Gianna Maria

    2016-03-12

    Inference of gene regulation from expression data may help to unravel regulatory mechanisms involved in complex diseases or in the action of specific drugs. A challenging task for many researchers working in the field of systems biology is to build up an experiment with a limited budget and produce a dataset suitable to reconstruct putative regulatory modules worth of biological validation. Here, we focus on small-scale gene expression screens and we introduce a novel experimental set-up and a customized method of analysis to make inference on regulatory modules starting from genetic perturbation data, e.g. knockdown and overexpression data. To illustrate the utility of our strategy, it was applied to produce and analyze a dataset of quantitative real-time RT-PCR data, in which interferon-α (IFN-α) transcriptional response in endothelial cells is investigated by RNA silencing of two candidate IFN-α modulators, STAT1 and IFIH1. A putative regulatory module was reconstructed by our method, revealing an intriguing feed-forward loop, in which STAT1 regulates IFIH1 and they both negatively regulate IFNAR1. STAT1 regulation on IFNAR1 was object of experimental validation at the protein level. Detailed description of the experimental set-up and of the analysis procedure is reported, with the intent to be of inspiration for other scientists who want to realize similar experiments to reconstruct gene regulatory modules starting from perturbations of possible regulators. Application of our approach to the study of IFN-α transcriptional response modulators in endothelial cells has led to many interesting novel findings and new biological hypotheses worth of validation.

  16. The development of a National set of Physiology learning objectives ...

    African Journals Online (AJOL)

    International Journal of Medicine and Health Development ... engagement that can be utilized to design a national set of learning objectives towards improving learning ... Key words: Learning objectives, Nigeria, Medical education, curriculum ...

  17. Effects of Inoculum Amount, Initial pH, and Nicotine Load on the Set-Up of Bioaugmented System with Pseudomonas Sp. HF-1 to Treat Tobacco Wastewater

    Directory of Open Access Journals (Sweden)

    Kun Zhang

    2014-01-01

    Full Text Available This study evaluated and optimized the influence of inoculum amount, initial pH, and nicotine load on the construction of Pseudomonas sp. HF-1 bioaugmented system for tobacco wastewater treatment. The results demonstrated that the optimum condition for the set-up of strain HF-1 bioaugmented system was 1.10 mg/g (dry weight of strain HF-1/dry weight of activated sludge of inoculum amount, initial pH 7.0, and 250–1000 mg/L nicotine load. Higher than 1.10 mg/g could lead to noncolonization of strain HF-1 in activated sludge and failure of set-up of this bioaugmented system. Higher than pH 8.0 could restrain the colonization of strain HF-1 in activated sludge. Even though strain HF-1 colonizes in the activated sludge when pH was above 8.0, the removal of nicotine and total organic carbon (TOC was suppressed due to low activities of bacteria in the activated sludge. Nicotine load did not show inhibition effect on set-up of bioaugmented system, but the ability of TOC removal was restrained when the nicotine load was above 1000 mg/L. This work could offer vital parameters for the set-up of bioaugmented system to treat tobacco wastewater in engineering.

  18. The method to set up file-6 in neutron data library of light nuclei below 20 MeV

    International Nuclear Information System (INIS)

    Zhang Jingshang; Han Yinlu

    2001-01-01

    So far there is no file-6 (double differential cross section data, DDX) of the light nuclei in the main evaluated neutron nuclear data libraries in the world. Therefore, locating a proper description on the double differential cross section of all kinds of outgoing particles from neutron induced light nucleus reaction below 20 MeV is necessary. The motivation for this work is to introduce a way to set up file-6 in the neutron data library

  19. Setting up the photoluminescence laboratory at ISOLDE & Perturbed Angular Correlation spectroscopy for BIO physics experiments using radioactive ions

    CERN Document Server

    Savva, Giannis

    2016-01-01

    The proposed project I was assigned was to set up the photoluminescence (PL) laboratory at ISOLDE, under the supervision of Karl Johnston. My first week at CERN coincided with the run of a BIO physics experiment using radioactive Hg(II) ions in which I also participated under the supervision of Stavroula Pallada. This gave me the opportunity to work in two projects during my stay at CERN and in the present report I describe briefly my contribution to them.

  20. Amendment of the Order of 2 November 1976 setting up an Institute for Protection and Nuclear Safety (29 October 1981)

    International Nuclear Information System (INIS)

    1981-01-01

    The Institute for Protection and Nuclear Safety was set up within the Atomic Energy Commission by an Order of 2 November 1976 now amended by this new Order, which specifies that, in connection with nuclear safety, the Institute provides direct technical support to the Central Service for the Safety of Nuclear Installations. (NEA) [fr

  1. Evaluation of set-up deviations during the irradiation of patients suffering from breast cancer treated with two different techniques

    International Nuclear Information System (INIS)

    KukoIowicz, Pawel Franciszek; Debrowski, Andrzej; Gut, Piotr; Chmielewski, Leszek; Wieczorek, Andrzej; Kedzierawski, Piotr

    2005-01-01

    Purpose: To compare reproducibility of set-up for two different treatment techniques for external irradiation of the breast. Methods and materials: In total, the analysis comprised 56 pairs of portal and simulator films for 14 consecutive patients treated following breast conserving therapy and 98 pairs of portal and simulator films for 20 consecutive patients treated after mastectomy. For the first group the tangential field technique (TF technique) was used, for the second the inverse hockey stick technique (IHS technique). Evaluation of the treatment reproducibility was performed in terms of systematic and random error calculated for the whole groups, comparison of set-up accuracy by means of comparison of cumulative distribution of the length of the displacement vector. Results: In the IHS and TF techniques for medial and lateral fields, displacement larger than 5 mm occurred in 28.3, 15.8 and 25.4%, respectively. For the IHS technique, the systematic errors for lateral and cranial-caudal direction were 1.9 and 1.7 mm, respectively (1 SD), the random errors for lateral and cranial-caudal direction were 2.0 and 2.5 mm. For the TF technique, the systematic errors for ventral-dorsal and cranial-caudal direction were 2.6 and 1.3 mm for medial field and 3.7 and 0.7 mm for lateral fields, respectively, the random errors for lateral and cranial-caudal direction were 2.2 and 1.0 mm for medial field and 2.9 and 1.1 for lateral field, respectively. Rotations were negligible in the IHS technique. For the TF technique the systematic and random components amounted to about 2.0 degrees (1 SD). Conclusions: Both the inverse hockey stick and standard tangential techniques showed good reproducibility of patients' set-up with respect to cranial-caudal direction. For the TF technique, the accuracy should be improved for the medial field with respect to the ventral-dorsal direction

  2. The new dedicated PIXE set-up at the National Environmental Research Institute, Denmark

    International Nuclear Information System (INIS)

    Kemp, Ka ring re; Waahlin, Peter

    1999-01-01

    The Niels Bohr Institute in Copenhagen was in the beginning of the 70'es one of the early places for PIXE. Contributions were made to the theoretical interpretation of the PIXE spectra as well as the practical application. The home-made 4 MV van de Graaff accelerator at the Niels Bohr Institute was an excellent tool for PIXE. The accelerator, which was used for many years, has now found its place on a museum after more than 40 years of active service. A dedicated PIXE set-up has now been established at the National Environmental Research Institute using a new 1.7 MV Tandem Pelletron (5SDH) from NEC. The main application is elemental analysis of outdoor aerosols. The main work is unsophisticated macro analyses, which do not push the equipment to its limits. This enables automated analysis of about 10,000 samples per year using very limited manpower resources. The research focuses on the contribution from various source types to the atmosphere over Europe, the North Atlantic and Greenland. Source compositions and their temporal variations are studied

  3. TEST BEAM COORDINATION: The 2004 Test Beam Calorimetry set-up in H8

    CERN Multimedia

    Aleksa, M; Di Girolamo, B; Ferrari, C; Giugni, D; Santoni, C; Wingerter, I

    A new table has been designed, built and finally mounted to position the LAr cryostat in front of the Tilecal modules. The new table has been connected to the existing Tilecal table to be able to move the full set-up along eta values between 0 and 1.2. The table has been conceived by D. Giugni (INFN Milano and now CERN PH) and modeled by G. Braga (INFN Milano) in spring-summer 2003. The realization of the table has been done by an Italian firm (MatecImpianti, Fenegrò, Como) under the supervision of S. Coelli (INFN Milano) starting August 2003. Figure 1 shows the table assembled at the firm (left). Figure 1: The Tilecal-LAr table: in Fenegro (left) and at CERN (right). In November 2003 the table has been delivered to CERN and put in temporary storage to be assembled after the preparation of the Tilecal zone. In February 2004 two technicians from the firm and the team of technician coordinated by C. Ferrari (CERN AB/ATB), assembled, tested and commissioned the table under the supervision of S. Coelli...

  4. Technical Development on Burn-up Credit for Spent LWR Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Gauld, I.C.

    2001-12-26

    Technical development on burn-up credit for spent LWR fuels had been performed at JAERI since 1990 under the contract with Science and Technology Agency of Japan entitled ''Technical Development on Criticality Safety Management for Spent LWR Fuels.'' Main purposes of this work are to obtain the experimental data on criticality properties and isotopic compositions of spent LWR fuels and to verify burnup and criticality calculation codes. In this work three major experiments of exponential experiments for spent fuel assemblies to obtain criticality data, non-destructive gamma-ray measurement of spent fuel rods for evaluating axial burn-up profiles, and destructive analyses of spent fuel samples for determining precise burn-up and isotopic compositions were carried out. The measured data obtained were used for validating calculation codes as well as an examination of criticality safety analyses. Details of the work are described in this report.

  5. Development of a portable x-ray tv camera set

    International Nuclear Information System (INIS)

    Panityotai, J.

    1990-01-01

    A portable X-ray T V camera set was developed using a 24 V battery as a power supply unit. The development aims at a non-film X-radiographic technique with low exposure radiation. The machine is able to catch one X-radiographic frame at a time with a resolution of 256 X 256 pixels under 64 gray scales. The investigation shows a horizontal resolution of 0.6 lines per millimeter and a vertical resolution of 0.7 lines per mi/limiter

  6. Development of land data sets for studies of global climate change

    International Nuclear Information System (INIS)

    Sadowski, F.G.; Watkins, A.H.

    1991-01-01

    The U.S. Geological Survey has begun a major initiative to organize, produce, and distribute land data sets that will support the land data requirements of the global change science community. Satellite image data sets, produced from the National Oceanic and Atmospheric Administration's Advanced Very High Resolution Radiometer sensors, will be developed to provide repetitive, synoptic coverage of regional, continental, and global land areas. These data sets, integrated with related land data and supplemented by coregistered Landsat data sets, will enable scientists to quantify the fundamental land surface attributes that are needed to model land surface processes, to detect and monitor land surface change, and to map land cover. These well-structured, consistent land data sets will form the historical record of land observations prior to the era of the National Aeronautics and Space Administration's Earth Observing System sensors

  7. Developing the Role of a Health Information Professional in a Clinical Research Setting

    Directory of Open Access Journals (Sweden)

    Helen M. Seeley

    2010-06-01

    Full Text Available Objective ‐ This paper examines the role of a health information professional in a large multidisciplinary project to improve services for head injury.Methods ‐ An action research approach was taken, with the information professional acting as co‐ordinator. Change management processes were guided by theory and evidence. The health information professional was responsible for an ongoing literature review on knowledge management (clinical and political issues, data collection and analysis (from patient records, collating and comparing data (to help develop standards, and devising appropriate dissemination strategies.Results ‐ Important elements of the health information management role proved to be 1 co‐ordination; 2 setting up mechanisms for collaborative learning through information sharing; and 3 using the theoretical frameworks (identified from the literature review to help guide implementation. The role that emerged here has some similarities to the informationist role that stresses domain knowledge, continuous learning and working in context (embedding. This project also emphasised the importance of co‐ordination, and the ability to work across traditional library information analysis (research literature discovery and appraisal and information analysis of patient data sets (the information management role.Conclusion ‐ Experience with this project indicates that health information professionals will need to be prepared to work with patient record data and synthesis of that data, design systems to co‐ordinate patient data collection, as well as critically appraise external evidence.

  8. Development of the International Spinal Cord Injury Activities and Participation Basic Data Set

    DEFF Research Database (Denmark)

    Post, M W; Charlifue, S; Biering-Sørensen, F

    2016-01-01

    on a three-point scale for each item completes the total of 24 A&P variables. CONCLUSION: Collection of the International SCI A&P Basic Data Set variables in all future research on SCI outcomes is advised to facilitate comparison of results across published studies from around the world. Additional......STUDY DESIGN: Consensus decision-making process. OBJECTIVES: The objective of this study was to develop an International Spinal Cord Injury (SCI) Activities and Participation (A&P) Basic Data Set. SETTING: International working group. METHODS: A committee of experts was established to select...... and define A&P data elements to be included in this data set. A draft data set was developed and posted on the International Spinal Cord Society (ISCoS) and American Spinal Injury Association websites and was also disseminated among appropriate organizations for review. Suggested revisions were considered...

  9. Establishing Medical Schools in Limited Resource Settings | Girma ...

    African Journals Online (AJOL)

    Establishing Medical Schools in Limited Resource Settings. ... These countries face challenges related to the rapid scale up which is mostly done without proper strategic planning, without the basic elements of infrastructure development, educational as well as academic and administrative human resources. Medical ...

  10. Comparison of different statistical methods for estimation of extreme sea levels with wave set-up contribution

    Science.gov (United States)

    Kergadallan, Xavier; Bernardara, Pietro; Benoit, Michel; Andreewsky, Marc; Weiss, Jérôme

    2013-04-01

    Estimating the probability of occurrence of extreme sea levels is a central issue for the protection of the coast. Return periods of sea level with wave set-up contribution are estimated here in one site : Cherbourg in France in the English Channel. The methodology follows two steps : the first one is computation of joint probability of simultaneous wave height and still sea level, the second one is interpretation of that joint probabilities to assess a sea level for a given return period. Two different approaches were evaluated to compute joint probability of simultaneous wave height and still sea level : the first one is multivariate extreme values distributions of logistic type in which all components of the variables become large simultaneously, the second one is conditional approach for multivariate extreme values in which only one component of the variables have to be large. Two different methods were applied to estimate sea level with wave set-up contribution for a given return period : Monte-Carlo simulation in which estimation is more accurate but needs higher calculation time and classical ocean engineering design contours of type inverse-FORM in which the method is simpler and allows more complex estimation of wave setup part (wave propagation to the coast for example). We compare results from the two different approaches with the two different methods. To be able to use both Monte-Carlo simulation and design contours methods, wave setup is estimated with an simple empirical formula. We show advantages of the conditional approach compared to the multivariate extreme values approach when extreme sea-level occurs when either surge or wave height is large. We discuss the validity of the ocean engineering design contours method which is an alternative when computation of sea levels is too complex to use Monte-Carlo simulation method.

  11. Expanding the test set: Chemicals with potential to disrupt mammalian brain development

    Science.gov (United States)

    High-throughput test methods including molecular, cellular, and alternative species-based assays that examine critical events of normal brain development are being developed for detection of developmental neurotoxcants. As new assays are developed, a "training set' of chemicals i...

  12. Introduction to Develop Some Software Programs for Dealing with Neutrosophic Sets

    Directory of Open Access Journals (Sweden)

    A. A. Salama

    2014-03-01

    Full Text Available In this paper, we have developed an Excel package to be utilized for calculating neutrosophic data and analyze them. The use of object oriented programming techniques and concepts as they may apply to the design and development a new framework to implement neutrosophic data operations, the c# programming language, NET Framework and Microsoft Visual Studio are used to implement the neutrosophic classes. We have used Excel as it is a powerful tool that is widely accepted and used for statistical analysis. Figure 1 shows Class Diagram of the implemented package. Figure 2 presents a working example of the package interface calculating the complement. Our implemented Neutrosophic package can calculate Intersection, Union, and Complement of the nuetrosophic set. Figure 3 presents our neutrosphic package capability to draw figures of presented neutrosphic set. Figure 4 presents charting of Union operation calculation, and figure 5 Intersection Operation. nuetrosophic set are characterized by its efficiency as it takes into consideration the three data items: True, Intermediate, and False.

  13. A look-up table for fully developed film-boiling heat transfer

    International Nuclear Information System (INIS)

    Groeneveld, D.C.; Leung, L.K.H.; Vasic, A.Z.; Guo, Y.J.; Cheng, S.C.

    2003-01-01

    An improved look-up table for film-boiling heat-transfer coefficients has been derived for steam-water flow inside vertical tubes. Compared to earlier versions of the look-up table, the following improvements were made: - The database has been expanded significantly. The present database contains 77,234 film-boiling data points obtained from 36 sources. - The upper limit of the thermodynamic quality range was increased from 1.2 to 2.0. The wider range was needed as non-equilibrium effects at low flows can extend well beyond the point where the thermodynamic quality equals unity. - The surface heat flux has been replaced by the surface temperature as an independent parameter. - The new look-up table is based only on fully developed film-boiling data. - The table entries at flow conditions for which no data are available is based on the best of five different film-boiling prediction methods. The new film-boiling look-up table predicts the database for fully developed film-boiling data with an overall rms error in heat-transfer coefficient of 10.56% and an average error of 1.71%. A comparison of the prediction accuracy of the look-up table with other leading film-boiling prediction methods shows that the look-up table results in a significant improvement in prediction accuracy

  14. Follow up: Compound data sets and software tools for chemoinformatics and medicinal chemistry applications: update and data transfer

    Science.gov (United States)

    Hu, Ye; Bajorath, Jürgen

    2014-01-01

    In 2012, we reported 30 compound data sets and/or programs developed in our laboratory in a data article and made them freely available to the scientific community to support chemoinformatics and computational medicinal chemistry applications. These data sets and computational tools were provided for download from our website. Since publication of this data article, we have generated 13 new data sets with which we further extend our collection of publicly available data and tools. Due to changes in web servers and website architectures, data accessibility has recently been limited at times. Therefore, we have also transferred our data sets and tools to a public repository to ensure full and stable accessibility. To aid in data selection, we have classified the data sets according to scientific subject areas. Herein, we describe new data sets, introduce the data organization scheme, summarize the database content and provide detailed access information in ZENODO (doi: 10.5281/zenodo.8451 and doi:10.5281/zenodo.8455). PMID:25520777

  15. Gov'tal FY 1987 draft budget for N-energy set at 360 billion yen, up 0.8 %

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The governmental draft budget for nuclear energy was approved on December 30. The total provided is 360,222 million yen, an increase of 0.8 % over the previous year. This is made up of general account, 183,308 million yen (1.4 % down) and special account for power resources development (related only to nuclear power) 175,914 million yen (up 3.2 %). The amount from the general account is reduced for the first time in three years. This decrease is due mainly to completion of the energy break-even plasma testing device for nuclear fusion research. The special account primarily represents the tax for promoting power source development, a kind of special purpose tax from the electric power companies, based on generated electricity, and from this, subsidies are paid to local municipalities for promotion of siting for power sources and for the cost of survey and research on the development of oil alternative power sources. The special account for power resources development consists of the power sources siting account, 68,114 million yen (up 4.5 %) and the power sources diversification account, 108,800 million yen (up 2.4 %). Nuclear energy budgets sought by the Science and Technology Agency, the Ministry of International Trade and Industry, and other government agencies are shown in Table. STA and MITI have both requested slightly less than in the preceding year from the general accout, but both asked for higher amounts from the special account than in the preceding year. The high rise in the amount sougt by other agencies is attributed to the increase in the cost of eradication of melon flies. (Nogami, K.)

  16. A Proposal to Speed up the Computation of the Centroid of an Interval Type-2 Fuzzy Set

    Directory of Open Access Journals (Sweden)

    Carlos E. Celemin

    2013-01-01

    Full Text Available This paper presents two new algorithms that speed up the centroid computation of an interval type-2 fuzzy set. The algorithms include precomputation of the main operations and initialization based on the concept of uncertainty bounds. Simulations over different kinds of footprints of uncertainty reveal that the new algorithms achieve computation time reductions with respect to the Enhanced-Karnik algorithm, ranging from 40 to 70%. The results suggest that the initialization used in the new algorithms effectively reduces the number of iterations to compute the extreme points of the interval centroid while precomputation reduces the computational cost of each iteration.

  17. The Development of an Automated Clean-up for Fat Extracts in the Routine Analysis of Organochlorine Compounds in Fish Meat

    Directory of Open Access Journals (Sweden)

    Ana Andreea CIOCA

    2017-05-01

    Full Text Available The present work describes the development of a new, automatic High Performance Liquid Chromatography (HPLC Clean-up step, in the methodology of sample preparation and multi-residue determination of organochlorine compounds (OCs in fish meat. 24 OCs were taken into study. In addition 7 Polychlorinated Biphenyls (PCBs, 7 chlorobenzene compounds and one 2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD were investigated. The HPLC conditions were established in accordance with the validated traditional Clean-up step of the laboratory. The technique was applied on a dilution of analytes of interest in order to establish the period of time in which the compounds are eluted. Another set of experiments involved fish oil, in order to identify and separate the fat fraction from the analytes. To confirm the findings of the experiments mentioned above, extracts of fish samples obtained after Accelerated Solvent Extraction (ASE were examined. The samples were spiked with the analytes of interest before HPLC clean-up step and quantified through Gas Chromatography coupled with tandem Mass Spectrometry (GC-MS/MS. A HPLC clean-up technique lasting 38 minutes/sample was developed. The method is not suitable for OCs such as Endosulfansulfat and Endrine Ketone due to the very low recovery results.Â

  18. Nuclear waste locked up in Synroc

    International Nuclear Information System (INIS)

    Grose, S.

    1998-01-01

    Australian technology Synroc leads the way in immobilizing nuclear waste. The ceramic approach set Synroc apart from glass-based technologies being developed in the US and Europe. Despite its international recognition, local industry failed to turn it into a commercial product. The author warns that if ANSTO is loosing the capacity to maintain Australian involvement in the development of Synroc, there is a danger that overseas interests would pick up the profit steam from this great Australian innovation

  19. CERN's Technician Training Experience notches up another success!

    CERN Multimedia

    Stephanie Hills

    2015-01-01

    The programme was set up almost three years ago to help address a Europe-wide shortage of highly skilled technicians, with the participants gaining valuable skills and experience in an international environment. It’s clear that the programme works: some of the technician fellows who have taken part are being snapped up by major science projects and the high-tech industry.   Going underground: Fay Chicken at work in ATLAS. Fay Chicken (see UK news from CERN 59) has just accepted a job offer from the European Spallation Source in Sweden, where she will be working in the detector development team: “I’m also going to be setting up a new workshop where prototype detectors will be built. When I went to Lund, I was shown a big, empty room – it’s up to me to equip it!” This level of responsibility is a big step up for Fay, but there is no doubt that her time at CERN has both built her confidence to take on the role, and convinced ESS th...

  20. The importance of site selection for setting up a wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Raghunandan, A.; Gowda, G.; Pandian, A. [MS RAMAIAH Institute of Technology, Bangalore (India); Ramanan, G. [RV College of Engineering, Bangalore (India)

    2012-07-01

    A wind energy system transforms the kinetic energy of the wind into mechanical or electrical energy that can be harnessed for practical use. Building a wind turbine is far more than simply a matter of finding a field or mountaintop where the wind is blowing and plopping one down. A great deal of attention should be given to finding the proper site for a wind turbine. The main factor one should consider is the average speed of the wind over an extended time. Estimation of the wind power potential for a site is the most important requirement for selecting a site for the installation of a wind turbine. Also wind turbines should be sited well above trees, buildings, and other obstacles else, the result will be poor energy production and increased wear and tear on the turbine. One way to get rid of this is to place the wind turbine on a tall tower. When selecting a place for setting up a wind turbine, engineers consider factors such as wind hazards, characteristics of the land that affect wind speed, and the effects of one turbine on nearby turbines in wind farms. The other factors that are important for selecting a site for installation of wind turbines are Hill effect, Roughness, or the amount of friction that Earth's surface exerts on wind, Tunnel effect, Turbulence, Variations in wind speed, Wind obstacles and Wind shear. This paper will emphasis on the necessary inspections which are to be done on the site before installing a Wind Turbine. (Author)

  1. Antagonistic effect of chosen lactic acid bacteria strains on Yersinia enterocolitica species in model set-ups, meat and fermented sausages.

    Science.gov (United States)

    Gomółka-Pawlicka, M; Uradziński, J

    2003-01-01

    The present study was aimed at determining the influence of 15 strains of lactic acid bacteria on the growth of 8 Yersinia enterocolitica strains in model set-ups, and in meat and ageing fermented sausages. The investigations were performed within the framework of three alternate stages which differed in respect to the products studied, the number of Lactobacillus sp. strains and, partly, methodological approach. The ratio between lactic acid bacteria and Yersinia enterocolitica strains studied was, depending on the variant of experiment, 1:1, 1:2 and 2:1, respectively. The study also considered water activity (aw) and pH of the products investigated. The results suggest that all the lactic acid bacteria strains used within the framework of the model set-ups had antagonistic effect on all the Salmonella sp. strains. However, this ability was not observed with respect to of tested lactic acid bacteria strains in meat and fermented sausage. This ability was possessed by one of the strains investigated--Lactobacillus helveticus T 78. The temperature and time of the incubation of sausages, but not aw and pH, were found to have a distinct influence on the antagonistic interaction between the bacteria tested.

  2. SU-E-CAMPUS-T-01: Analysis of the Precision of Patient Set-Up, and Fidelity of the Delivered Dose Distribution in Proton Therapy of Ocular Tumors

    International Nuclear Information System (INIS)

    Trofimov, A; Carpenter, K; Shih, HA

    2014-01-01

    Purpose: To quantify daily set-up variations in fractionated proton therapy of ocular melanomas, and to assess the effect on the fidelity of delivered distribution to the plan. Methods: In a typical five-fraction course, daily set-up is achieved by matching the position of fiducial markers in orthogonal radiographs to the images generated by treatment planning program. A patient maintains the required gaze direction voluntarily, without the aid of fixation devices. Confirmation radiographs are acquired to assess intrafractional changes. For this study, daily radiographs were analyzed to determine the daily iso-center position and apparent gaze direction, which were then transferred to the planning system to calculate the dose delivered in individual fractions, and accumulated dose for the entire course. Dose-volume metrics were compared between the planned and accumulated distributions for the tumor and organs at risk, for representative cases that varied by location within the ocular globe. Results: The analysis of the first set of cases (3 posterior, 3 transequatorial and 4 anterior tumors) revealed varying dose deviation patterns, depending on the tumor location. For anterior and posterior tumors, the largest dose increases were observed in the lens and ciliary body, while for the equatorial tumors, macula, optic nerve and disk, were most often affected. The iso-center position error was below 1.3 mm (95%-confidence interval), and the standard deviation of daily polar and azimuthal gaze set-up were 1.5 and 3 degrees, respectively. Conclusion: We quantified interfractional and intrafractional set-up variation, and estimated their effect on the delivered dose for representative cases. Current safety margins are sufficient to maintain the target coverage, however, the dose delivered to critical structures often deviates from the plan. The ongoing analysis will further explore the patterns of dose deviation, and may help to identify particular treatment scenarios

  3. SU-E-CAMPUS-T-01: Analysis of the Precision of Patient Set-Up, and Fidelity of the Delivered Dose Distribution in Proton Therapy of Ocular Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Trofimov, A; Carpenter, K; Shih, HA [Massachusetts General Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: To quantify daily set-up variations in fractionated proton therapy of ocular melanomas, and to assess the effect on the fidelity of delivered distribution to the plan. Methods: In a typical five-fraction course, daily set-up is achieved by matching the position of fiducial markers in orthogonal radiographs to the images generated by treatment planning program. A patient maintains the required gaze direction voluntarily, without the aid of fixation devices. Confirmation radiographs are acquired to assess intrafractional changes. For this study, daily radiographs were analyzed to determine the daily iso-center position and apparent gaze direction, which were then transferred to the planning system to calculate the dose delivered in individual fractions, and accumulated dose for the entire course. Dose-volume metrics were compared between the planned and accumulated distributions for the tumor and organs at risk, for representative cases that varied by location within the ocular globe. Results: The analysis of the first set of cases (3 posterior, 3 transequatorial and 4 anterior tumors) revealed varying dose deviation patterns, depending on the tumor location. For anterior and posterior tumors, the largest dose increases were observed in the lens and ciliary body, while for the equatorial tumors, macula, optic nerve and disk, were most often affected. The iso-center position error was below 1.3 mm (95%-confidence interval), and the standard deviation of daily polar and azimuthal gaze set-up were 1.5 and 3 degrees, respectively. Conclusion: We quantified interfractional and intrafractional set-up variation, and estimated their effect on the delivered dose for representative cases. Current safety margins are sufficient to maintain the target coverage, however, the dose delivered to critical structures often deviates from the plan. The ongoing analysis will further explore the patterns of dose deviation, and may help to identify particular treatment scenarios

  4. NextUp: Intentional Faculty Leadership Development for All Ranks and Disciplines

    Science.gov (United States)

    Ashe, Diana L.; TenHuisen, Matthew L.

    2018-01-01

    While most academic leadership training focuses on department chairs and those already in or identified for those positions, the NextUp Faculty Leadership Development Fellows program includes faculty who are considering academic leadership of any kind in their careers. Sixty faculty members have joined NextUp; forty-one have graduated and 19 are…

  5. Prompt-gamma neutron activation analysis for the non-destructive characterization of radioactive wastes; Prompt-Gamma-Neutronen-Aktivierungs-Analyse zur zerstoerungsfreien Charakterisierung radioaktiver Abfaelle

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, John Paul Hermann

    2010-07-01

    In Germany, stringent official regulations govern the handling and final storage of radioactive waste. For this reason, the Federal Government has opted for final storage of radioactive waste with negligible heat generation in deep geological formations. At present the Konrad mine in Salzgitter will be rebuilt as a final disposal, the start of operation is scheduled for 2014. Radioactive waste with negligible heat generation originates from the operation and decommissioning of nuclear power plants, the medical sector or from research establishments. The requirements of the planning approval decision to build up the disposal Konrad, published on the 22{sup nd} of May 2002, obligate the waste producer to consider the limits for chemotoxic substances and to document the waste content. Before the radioactive waste can be stored in the final disposal, it is necessary to characterize the waste composition, relating to the concentration of water polluting substances. In particular for the wastes produced in the year before 1990, the so-called old wastes, there is a lack of documentation. The chemotoxicity of old wastes can mostly only characterized by time consuming and destructive methods. Furthermore these methods produce high costs, which depend on the arrangements to avoid contamination, to comply with the radiation protection and for the conditioning of the wastes. A prototype system, based on the Prompt-Gamma-Neutron-Activation-Analysis (PGNAA) with 14 MeV neutrons, has been developed in this work. This system allows the characterization of large samples, like 25 and 50 l drums. The signature of the element composition is in this processed by gamma-ray spectroscopy. This work was focused, in addition to the feasibility of the system, to the neutron and photon transport in large samples. Therefore the neutron and photon self-absorption in dependence of the sample composition were the main part of interest. Computer simulations (MCNP) and experiments were performed to

  6. Thorium molecular negative ion production in a cesium sputter source at BARC-TIFR pelletron accelerator ion source test set up

    International Nuclear Information System (INIS)

    Gupta, A.K.; Mehrotra, N.; Kale, R.M.; Alamelu, D.; Aggarwal, S.K.

    2005-01-01

    Ion source test set up at Pelletron Accelerator facility has been utilized extensively for the production and characterization of negative ions, with particular emphasis being place at the species of experimental users interest. The attention have been focussed towards the formation of rare earth negative ions, due to their importance in the ongoing accelerator mass spectroscopy program and isotopic abundance measurements using secondary negative ion mass spectrometry

  7. Friendly vertical housing: case of walk-up flat housing development in Yogyakarta

    Science.gov (United States)

    Fosterharoldas Swasto, Deva

    2018-03-01

    In Yogyakarta Province, the local government have developed walk-up flats housing for more than ten years since the mid of the 2000s. Yogyakarta City and Sleman Regency was pioneering the construction with some blocks of flats in several locations. However, after this period, there is limited evaluation about the effectiveness of the occupancy. One of the issues is related to the sustainable housing development. Concerning this situation, it is proposed to examine how the development of walk-up flats housing in Yogyakarta City and Sleman Regency can be evaluated based on specific housing indicator, as a part of sustainable housing development concept. This paper would like to explore the phenomenon on how ‘friendly’ the flats is. The researcher will qualitatively asses variables from the walk-up flat cases in Yogyakarta City and Sleman Regency. The results suggested that the physical quality of the vertical housing situation could be enhanced to meet residents’ satisfaction.

  8. Development of a microsatellite primer set to investigate the genetic ...

    Indian Academy of Sciences (India)

    Development of a microsatellite primer set to investigate the genetic population structure of Armadillidium nasatum (Crustacea, Oniscidea). Séverine Masson, Cédric Faivre, Isabelle Giraud, Catherine Souty-Grosset, Richard Cordaux, Carine Delaunay,. Didier Bouchon and Nicolas Bech. J. Genet. 93, 545-549. Table 1.

  9. Millions Learning: Scaling up Quality Education in Developing Countries

    Science.gov (United States)

    Robinson, Jenny Perlman; Winthrop, Rebecca

    2016-01-01

    "Millions Learning: Scaling up Quality Education in Developing Countries" tells the story of where and how quality education has scaled in low- and middle-income countries. The story emerges from wide-ranging research on scaling and learning, including 14 in-depth case studies from around the globe. Ultimately, "Millions…

  10. Simulation of prompt gamma rays spectra: calibration for pollutants determination in voluminous samples

    International Nuclear Information System (INIS)

    Khelifi, R.; Idiri, Z.; Amokrane, A.; Bode, P.

    2006-01-01

    A PGNAA facility using Am-Be source has been developed with the aim of analyzing the major composition of various elements in aqueous samples. A program of simulation for gamma rays spectra was developed to estimate the detection limits of pollutants. The background line under photo peaks of interest was simulated using experimental data. The reliability of the program was checked under real conditions with solutions containing various salt concentrations. Experimental and simulated spectra were found to be in good agreement. (author)

  11. Estimating the CCSD basis-set limit energy from small basis sets: basis-set extrapolations vs additivity schemes

    Energy Technology Data Exchange (ETDEWEB)

    Spackman, Peter R.; Karton, Amir, E-mail: amir.karton@uwa.edu.au [School of Chemistry and Biochemistry, The University of Western Australia, Perth, WA 6009 (Australia)

    2015-05-15

    Coupled cluster calculations with all single and double excitations (CCSD) converge exceedingly slowly with the size of the one-particle basis set. We assess the performance of a number of approaches for obtaining CCSD correlation energies close to the complete basis-set limit in conjunction with relatively small DZ and TZ basis sets. These include global and system-dependent extrapolations based on the A + B/L{sup α} two-point extrapolation formula, and the well-known additivity approach that uses an MP2-based basis-set-correction term. We show that the basis set convergence rate can change dramatically between different systems(e.g.it is slower for molecules with polar bonds and/or second-row elements). The system-dependent basis-set extrapolation scheme, in which unique basis-set extrapolation exponents for each system are obtained from lower-cost MP2 calculations, significantly accelerates the basis-set convergence relative to the global extrapolations. Nevertheless, we find that the simple MP2-based basis-set additivity scheme outperforms the extrapolation approaches. For example, the following root-mean-squared deviations are obtained for the 140 basis-set limit CCSD atomization energies in the W4-11 database: 9.1 (global extrapolation), 3.7 (system-dependent extrapolation), and 2.4 (additivity scheme) kJ mol{sup –1}. The CCSD energy in these approximations is obtained from basis sets of up to TZ quality and the latter two approaches require additional MP2 calculations with basis sets of up to QZ quality. We also assess the performance of the basis-set extrapolations and additivity schemes for a set of 20 basis-set limit CCSD atomization energies of larger molecules including amino acids, DNA/RNA bases, aromatic compounds, and platonic hydrocarbon cages. We obtain the following RMSDs for the above methods: 10.2 (global extrapolation), 5.7 (system-dependent extrapolation), and 2.9 (additivity scheme) kJ mol{sup –1}.

  12. Estimating the CCSD basis-set limit energy from small basis sets: basis-set extrapolations vs additivity schemes

    International Nuclear Information System (INIS)

    Spackman, Peter R.; Karton, Amir

    2015-01-01

    Coupled cluster calculations with all single and double excitations (CCSD) converge exceedingly slowly with the size of the one-particle basis set. We assess the performance of a number of approaches for obtaining CCSD correlation energies close to the complete basis-set limit in conjunction with relatively small DZ and TZ basis sets. These include global and system-dependent extrapolations based on the A + B/L α two-point extrapolation formula, and the well-known additivity approach that uses an MP2-based basis-set-correction term. We show that the basis set convergence rate can change dramatically between different systems(e.g.it is slower for molecules with polar bonds and/or second-row elements). The system-dependent basis-set extrapolation scheme, in which unique basis-set extrapolation exponents for each system are obtained from lower-cost MP2 calculations, significantly accelerates the basis-set convergence relative to the global extrapolations. Nevertheless, we find that the simple MP2-based basis-set additivity scheme outperforms the extrapolation approaches. For example, the following root-mean-squared deviations are obtained for the 140 basis-set limit CCSD atomization energies in the W4-11 database: 9.1 (global extrapolation), 3.7 (system-dependent extrapolation), and 2.4 (additivity scheme) kJ mol –1 . The CCSD energy in these approximations is obtained from basis sets of up to TZ quality and the latter two approaches require additional MP2 calculations with basis sets of up to QZ quality. We also assess the performance of the basis-set extrapolations and additivity schemes for a set of 20 basis-set limit CCSD atomization energies of larger molecules including amino acids, DNA/RNA bases, aromatic compounds, and platonic hydrocarbon cages. We obtain the following RMSDs for the above methods: 10.2 (global extrapolation), 5.7 (system-dependent extrapolation), and 2.9 (additivity scheme) kJ mol –1

  13. The Build-Up to Eruptive Solar Events Viewed as the Development of Chiral Systems

    Science.gov (United States)

    Martin, S. F.; Panasenco, O.; Berger, M. A.; Engvold, O.; Lin, Y.; Pevtsov, A. A.; Srivastava, N.

    2012-12-01

    When we examine the chirality or observed handedness of the chromospheric and coronal structures involved in the long-term build-up to eruptive events, we find that they evolve in very specific ways to form two and only two sets of large-scale chiral systems. Each system contains spatially separated components with both signs of chirality, the upper portion having negative (positive) chirality and the lower part possessing positive (negative) chirality. The components within a system are a filament channel (represented partially by sets of chromospheric fibrils), a filament (if present), a filament cavity, sometimes a sigmoid, and always an overlying arcade of coronal loops. When we view these components as parts of large-scale chiral systems, we more clearly see that it is not the individual components of chiral systems that erupt but rather it is the approximate upper parts of an entire evolving chiral system that erupts. We illustrate the typical pattern of build-up to eruptive solar events first without and then including the chirality in each stage of the build-up. We argue that a complete chiral system has one sign of handedness above the filament spine and the opposite handedness in the barbs and filament channel below the filament spine. If the spine has handedness, the observations favor its having the handedness of the filament cavity and coronal loops above. As the separate components of a chiral system form, we show that the system appears to maintain a balance of right-handed and left-handed features, thus preserving an initial near-zero net helicity. We further argue that the chiral systems allow us to identify key sites of energy transformation and stored energy later dissipated in the form of concurrent CMEs, erupting filaments and solar flares. Each individual chiral system may produce many successive eruptive events above a single filament channel. Because major eruptive events apparently do not occur independent of, or outside of, these unique

  14. Spatially and time-resolved element-specific in situ corrosion investigations with an online hyphenated microcapillary flow injection inductively coupled plasma mass spectrometry set-up

    International Nuclear Information System (INIS)

    Homazava, N.; Ulrich, A.; Kraehenbuehl, U.

    2008-01-01

    A novel technique for in situ spatial, time-resolved element-specific investigations of corrosion processes is developed. The technique is based on an online hyphenation of a specially designed microflow-capillary set-up to inductively coupled plasma mass spectrometry (ICP-MS) using flow injection sample introduction. Detailed aspects of the method development, optimization of the sample microflow introduction and flow injection characteristics for the localized corrosion analysis are described. Moreover, specific challenges of the ICP-MS analysis as applied to the analysis of corrosion sample probes, e.g. high matrix load and limited sample volume, are discussed. The efficiency of the developed technique is proved by corrosion susceptibility analysis of a commercial Al alloy. Results of the corrosion experiments of the aluminum alloy AA 6111 are presented to demonstrate the influence of various factors such as exposure time and pH value of the corrosive medium on the element-specific dissolution rates of the alloy. This novel technique provides new aspects in corrosion science and sheds new light on corrosion mechanisms

  15. Adult 4-H Volunteer Empowerment in 4-H Youth Development Settings

    Science.gov (United States)

    Olsen, Pamela

    2009-01-01

    The primary purpose of this study was to determine which factors related to adult 4-H volunteer empowerment in 4-H youth development settings. This study examined the relationship of adult 4-H volunteers' perceived leadership styles of Oregon 4-H Youth Development Educators (YDE) to the adult 4-H volunteer sense of empowerment. In addition,…

  16. Development of a phenomena identification and ranking table using fuzzy set theory

    International Nuclear Information System (INIS)

    Kljenak, I.; Jordan Cizelj, R.; Prosek, A.

    2001-01-01

    The use of fuzzy set theory in the development of Phenomena Identification and Ranking Table for a nuclear power plant transient is presented. Fuzzy set theory was used to aggregate the opinions from different experts concerning the importance of individual basic phenomena with respect to safety criteria. The use of fuzzy set theory is particularly adequate, as experts' opinions are inherently imprecise and uncertain. The method is presented on the specific case of a small-break loss-of-coolant accident in a two-loop pressurized water reactor. (author)

  17. Patient responses to research recruitment and follow-up surveys: findings from a diverse multicultural health care setting in Qatar

    Directory of Open Access Journals (Sweden)

    Amal Khidir

    2016-01-01

    Full Text Available Abstract Background Health care researchers working in the Arabian Gulf need information on how to optimize recruitment and retention of study participants in extremely culturally diverse settings. Implemented in Doha, Qatar in 2012 with 4 language groups, namely Arabic, English, Hindi, and Urdu, this research documents persons’ responses to recruitment, consent, follow-up, and reminder procedures during psychometric testing of the Multicultural Assessment Instrument (MAI, a novel self- or interviewer-administered survey. Methods Bilingual research assistants recruited adults in outpatient clinics by approaching persons in particular who appeared to be from a target language group. Participants completed the MAI, a second acculturation instrument used for content-validity assessment, and a demographics questionnaire. Participants were asked to take the MAI again in 2–3 weeks, in person or by post, to assess test-retest reliability. Recruitment data were analyzed by using nonparametric statistics. Results Of 1503 persons approached during recruitment, 400 enrolled (27 %—100 per language group. The enrollment rates in the language groups were: Arabic-32 %; English-33 %; Hindi-18 %; Urdu-30 %. The groups varied somewhat in their preferences regarding consent procedure, follow-up survey administration, contact mode for follow-up reminders, and disclosure of personal mailing address (for postal follow-up. Over all, telephone was the preferred medium for follow-up reminders. Of 64 persons who accepted a research assistant’s invitation for in-person follow-up, 40 participants completed the interview (follow-up rate, 63 %; among 126 persons in the postal group with a deliverable address, 29 participants mailed back a completed follow-up survey (response rate, 23 %. Conclusions Researchers in the Arabian Gulf face challenges to successfully identify, enroll, and retain eligible study participants. Although bilingual assistants

  18. Electron beam weld parameter set development and cavity cost

    International Nuclear Information System (INIS)

    John Brawley; John Mammossor; Larry Philips

    1997-01-01

    Various methods have recently been considered for use in the cost-effective manufacturing of large numbers of niobium cavities. A method commonly assumed to be too expensive is the joining of half cells by electron beam welding (EBW), as has been done with multipurpose EBW equipment for producing small numbers of cavities at accelerator laboratories. The authors have begun to investigate the advantages that would be available if a single-purpose, task-specific EBW processing tool were used to produce cavities in a high-volume commercial-industrial context. For such a tool and context they have sought to define an EBW parameter set that is cost-effective not only in terms of per-cavity production cost, but also in terms of the minimization of quench-producing weld defects. That is, they define cavity cost-effectiveness to include both production and performance costs. For such an EBW parameter set, they have developed a set of ideal characteristics, produced and tested samples and a complete cavity, studied the weld-defect question, and obtained industrial estimates of cavity high-volume production costs. The investigation in ongoing. This paper reports preliminary findings

  19. Fundamental about energy-efficient set-top boxes; Grundlagen zur Energieeffizienz von Set-Top Boxen

    Energy Technology Data Exchange (ETDEWEB)

    Grieder, T.; Huser, A.

    2004-07-01

    In various countries within Europe, digital television has already achieved a wide distribution. All types of reception are affected by this new technology, cable television, satellite reception and reception with a conventional roof or room aerial. In addition to the television set itself, a separate receiver is required for the digital signals, a so-called set-top box. Instead of one analogue programme, at least 3, or, in extreme cases more than 10, digital programmes are received, with interactive ser-vices also being possible. Up to now, very little of this development has been seen in Switzerland. Thanks to the wide range of programmes available over the cable networks, there is virtually no demand for an improved offer via a conventional aerial. Only in the case of satellite reception has the changeover already taken place in the majority of cases. Attractive additional services, as well as the integration into the international environment, will result in an increasing number of set-top boxes also being used in Switzerland. Over the next 10 to 15 years, the current number of approximately 420,000 units will increase to over 3 million, whereby the total electricity demand within Switzerland will increase by a further 0.5 to 1%. In order to check this increase, the European Union has taken the path of a voluntary agreement with the appliance manufacturers and service providers, and a similar procedure is also recommended for Switzerland. In addition, this study also draws up various recommendations for the importers of set-top boxes and for the service providers. (author)

  20. Setting up a parathyroid multidisciplinary team meeting: one year's experience, outcomes and learning points.

    Science.gov (United States)

    Hancox, S H; Sinnott, J D; Kirkland, P; Lipscomb, D; Owens, E; Howlett, D C

    2018-03-01

    A parathyroid multidisciplinary team meeting was set up at East Sussex Healthcare Trust, from November 2014 to November 2015, in order to improve and streamline services for patients with parathyroid pathology. Data were collected on all new referrals for hyperparathyroidism, and on the outcomes for each patient discussed at the meeting, including the number of operations and management outcomes. A survey was sent out to the members of the multidisciplinary team meeting to determine their perception of its effectiveness. Seventy-nine new referrals were discussed throughout the year; 43 per cent were recommended for surgery, 41 per cent had a trial of conservative or medical management before re-discussion, and 16 per cent required further imaging. Ninety-two per cent of patients underwent an ultrasound, single-photon emission computed tomography/computed tomography or nuclear medicine (sestamibi) scan prior to the meeting. All ultrasound scans were performed by a consultant radiologist. The multidisciplinary team meeting has been successful, with perceived benefits for patients, improved imaging evaluation and efficiency of referral pathways, leading to more appropriate patient management.

  1. A randomized controlled trial comparing customized versus standard headrests for head and neck radiotherapy immobilization in terms of set-up errors, patient comfort and staff satisfaction (ICORG 08-09)

    International Nuclear Information System (INIS)

    Howlin, C.; O'Shea, E.; Dunne, M.; Mullaney, L.; McGarry, M.; Clayton-Lea, A.; Finn, M.; Carter, P.; Garret, B.; Thirion, P.

    2015-01-01

    Purpose: To recommend a specific headrest, customized or standard, for head and neck radiotherapy patients in our institution based primarily on an evaluation of set-up accuracy, taking into account a comparison of patient comfort, staff and patient satisfaction, and resource implications. Methods and materials: Between 2008 and 2009, 40 head and neck patients were randomized to either a standard (Arm A, n = 21) or customized (Arm B, n = 19) headrest, and immobilized with a customized thermoplastic mask. Set-up accuracy was assessed using electronic portal images (EPI). Random and systematic set-up errors for each arm were determined from 668 EPIs, which were analyzed by one Radiation Therapist. Patient comfort was assessed using a visual analogue scale (VAS) and staff satisfaction was measured using an in-house questionnaire. Resource implications were also evaluated. Results: The difference in set-up errors between arms was not significant in any direction. However, in this study the standard headrest (SH) arm performed well, with set-up errors comparative to customized headrests (CHs) in previous studies. CHs require regular monitoring and 47% were re-vacuumed making them more resource intensive. Patient comfort and staff satisfaction were comparable in both arms. Conclusion: The SH provided similar treatment accuracy and patient comfort compared with the CH. The large number of CHs that needed to be re-vacuumed undermines their reliability for radiotherapy schedules that extend beyond 34 days from the initial CT scan. Accordingly the CH was more resource intensive without improving the accuracy of positioning, thus the standard headrest is recommended for continued use at our institution

  2. Setting up a Bioluminescence Resonance Energy Transfer high throughput screening assay to search for protein/protein interaction inhibitors in mammalian cells.

    Directory of Open Access Journals (Sweden)

    Cyril eCouturier

    2012-09-01

    Full Text Available Each step of the cell life and its response or adaptation to its environment are mediated by a network of protein/protein interactions termed interactome. Our knowledge of this network keeps growing due to the development of sensitive techniques devoted to study these interactions. The bioluminescence resonance energy transfer (BRET technique was primarily developed to allow the dynamic monitoring of protein-protein interactions in living cells, and has widely been used to study receptor activation by intra- or extra-molecular conformational changes within receptors and activated complexes in mammal cells. Some interactions are described as crucial in human pathological processes, and a new class of drugs targeting them has recently emerged. The BRET method is well suited to identify inhibitors of protein-protein interactions and here is described why and how to set up and optimize a High Throughput Screening assay based on BRET to search for such inhibitory compounds. The different parameters to take into account when developing such BRET assays in mammal cells are reviewed to give general guidelines: considerations on the targeted interaction, choice of BRET version, inducibility of the interaction, kinetic of the monitored interaction, and of the BRET reading, influence substrate concentration, number of cells and medium composition used on the Z’ factor, and expected interferences for colored or fluorescent compounds.

  3. 'TeamUP': An approach to developing teamwork skills in undergraduate midwifery students.

    Science.gov (United States)

    Hastie, Carolyn Ruth

    2018-03-01

    to develop an effective model to enable educators to teach, develop and assess the development of midwifery students' teamwork skills DESIGN: an action research project involving participant interviews and academic feedback. a regional university PARTICIPANTS: midwifery students (n = 21) and new graduate midwives (n = 20) INTERVENTIONS: a whole of course program using a rubric, with five teamwork domains and behavioural descriptors, to provide a framework for teaching and assessment. Students self and peer assess. Lectures, tutorials and eight different groupwork assignments of increasing difficulty, spread over the three years of the undergraduate degree are incorporated into the TeamUP model. the assignments provide students with the opportunity to practice and develop their teamwork skills in a safe, supported environment. the social, emotional and practical behaviours required for effective teamwork can be taught and developed in undergraduate health students. students require a clear overview of the TeamUP model at the beginning of the degree. They need to be informed of the skills and behaviours that the TeamUP model is designed to help develop and why they are important. The success of the model depends upon the educator's commitment to supporting students to learn teamwork skills. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  4. Does mode of follow-up influence contraceptive use after medical abortion in a low-resource setting? Secondary outcome analysis of a non-inferiority randomized controlled trial.

    Science.gov (United States)

    Paul, Mandira; Iyengar, Sharad D; Essén, Birgitta; Gemzell-Danielsson, Kristina; Iyengar, Kirti; Bring, Johan; Klingberg-Allvin, Marie

    2016-10-17

    Post-abortion contraceptive use in India is low and the use of modern methods of contraception is rare, especially in rural areas. This study primarily compares contraceptive use among women whose abortion outcome was assessed in-clinic with women who assessed their abortion outcome at home, in a low-resource, primary health care setting. Moreover, it investigates how background characteristics and abortion service provision influences contraceptive use post-abortion. A randomized controlled, non-inferiority, trial (RCT) compared clinic follow-up with home-assessment of abortion outcome at 2 weeks post-abortion. Additionally, contraceptive-use at 3 months post-abortion was investigated through a cross-sectional follow-up interview with a largely urban sub-sample of women from the RCT. Women seeking abortion with a gestational age of up to 9 weeks and who agreed to a 2-week follow-up were included (n = 731). Women with known contraindications to medical abortions, Hb Contraceptive use was measured at 2 weeks among women successfully followed-up (n = 623) and 3 months in the sub-set of women who were included if they were recruited at one of the urban study sites, owned a phone and agreed to a 3-month follow-up (n = 114). There were no differences between contraceptive use and continuation between study groups at 3 months (76 % clinic follow-up, 77 % home-assessment), however women in the clinic follow-up group were most likely to adopt a contraceptive method at 2 weeks (62 ± 12 %), while women in the home-assessment group were most likely to adopt a method after next menstruation (60 ± 13 %). Fifty-two per cent of women who initiated a method at 2 weeks chose the 3-month injection or the copper intrauterine device. Only 4 % of women preferred sterilization. Caste, educational attainment, or type of residence did not influence contraceptive use. Simplified follow-up after early medical abortion will not change women

  5. A Photometric Observing Program at the VATT: Setting Up a Calibration Field

    Science.gov (United States)

    Davis Philip, A. G.; Boyle, R. P.; Janusz, R.

    2009-05-01

    Philip and Boyle have been making Strömgren and then Strömvil photometric observations of open and globular clusters at the Vatican Advanced Technology Telescope located on Mt. Graham in Arizona. Our aim is to obtain CCD photometric indices good to 0.01 magnitude. Indices of this quality can later be analyzed to yield estimates of temperature, luminosity and metallicity. But we have found that the CCD chip does not yield photometry of this quality without further corrections. Our most observed cluster is the open cluster, M 67. This cluster is also very well observed in the literature. We took the best published values and created a set of "standard" stars for our field. Taking our CCD results we could calculate deltas, as a function of position on the chip, which we then applied to all the CCD frames that we obtained. With this procedure we were able to obtain the precision of 0.01 magnitudes in all the fields that we observed. When we started we were able to use the "A" two-inch square Strömgren four-color set from KPNO. Later the Vatican Observatory bought a set of 3.48 inch square Strömgren filters, The Vatican Observatory had a set of circular Vilnius filters There was also an X filter. These eight filters made our Strömvil set.

  6. Decree No. 77-1233 of 10 November 1977 setting up a Council for information on nuclear electricity generation

    International Nuclear Information System (INIS)

    1977-01-01

    This Decree sets up a Council for information on nuclear electricity generation directly under the authority of and appointed by the Prime Minister. It has 18 members who include, inter alia, mayors of the communes concerned by nuclear power plant siting, representatives of nature and environmental protection associations, science academicians and economics, energy and communications experts. The Council's purpose is to ensure that the public has access to infomation on nuclear electricity generation from the technical, health, ecological, economic and financial viewpoints. It advises the Government on the public's conditions of access to information and proposes methods for its dissemination. (NEA) [fr

  7. Beam patterns in an optical parametric oscillator set-up employing walk-off compensating beta barium borate crystals

    Science.gov (United States)

    Kaucikas, M.; Warren, M.; Michailovas, A.; Antanavicius, R.; van Thor, J. J.

    2013-02-01

    This paper describes the investigation of an optical parametric oscillator (OPO) set-up based on two beta barium borate (BBO) crystals, where the interplay between the crystal orientations, cut angles and air dispersion substantially influenced the OPO performance, and especially the angular spectrum of the output beam. Theory suggests that if two BBO crystals are used in this type of design, they should be of different cuts. This paper aims to provide an experimental manifestation of this fact. Furthermore, it has been shown that air dispersion produces similar effects and should be taken into account. An x-ray crystallographic indexing of the crystals was performed as an independent test of the above conclusions.

  8. Beam patterns in an optical parametric oscillator set-up employing walk-off compensating beta barium borate crystals

    International Nuclear Information System (INIS)

    Kaucikas, M; Warren, M; Van Thor, J J; Michailovas, A; Antanavicius, R

    2013-01-01

    This paper describes the investigation of an optical parametric oscillator (OPO) set-up based on two beta barium borate (BBO) crystals, where the interplay between the crystal orientations, cut angles and air dispersion substantially influenced the OPO performance, and especially the angular spectrum of the output beam. Theory suggests that if two BBO crystals are used in this type of design, they should be of different cuts. This paper aims to provide an experimental manifestation of this fact. Furthermore, it has been shown that air dispersion produces similar effects and should be taken into account. An x-ray crystallographic indexing of the crystals was performed as an independent test of the above conclusions. (paper)

  9. How large a training set is needed to develop a classifier for microarray data?

    Science.gov (United States)

    Dobbin, Kevin K; Zhao, Yingdong; Simon, Richard M

    2008-01-01

    A common goal of gene expression microarray studies is the development of a classifier that can be used to divide patients into groups with different prognoses, or with different expected responses to a therapy. These types of classifiers are developed on a training set, which is the set of samples used to train a classifier. The question of how many samples are needed in the training set to produce a good classifier from high-dimensional microarray data is challenging. We present a model-based approach to determining the sample size required to adequately train a classifier. It is shown that sample size can be determined from three quantities: standardized fold change, class prevalence, and number of genes or features on the arrays. Numerous examples and important experimental design issues are discussed. The method is adapted to address ex post facto determination of whether the size of a training set used to develop a classifier was adequate. An interactive web site for performing the sample size calculations is provided. We showed that sample size calculations for classifier development from high-dimensional microarray data are feasible, discussed numerous important considerations, and presented examples.

  10. Sets, Planets, and Comets

    Science.gov (United States)

    Baker, Mark; Beltran, Jane; Buell, Jason; Conrey, Brian; Davis, Tom; Donaldson, Brianna; Detorre-Ozeki, Jeanne; Dibble, Leila; Freeman, Tom; Hammie, Robert; Montgomery, Julie; Pickford, Avery; Wong, Justine

    2013-01-01

    Sets in the game "Set" are lines in a certain four-dimensional space. Here we introduce planes into the game, leading to interesting mathematical questions, some of which we solve, and to a wonderful variation on the game "Set," in which every tableau of nine cards must contain at least one configuration for a player to pick up.

  11. "Ready, Set, FLOW!"

    Science.gov (United States)

    Stroud, Wesley

    2018-01-01

    All educators want their classrooms to be inviting areas that support investigations. However, a common mistake is to fill learning spaces with items or objects that are set up by the teacher or are simply "for show." This type of setting, although it may create a comfortable space for students, fails to stimulate investigations and…

  12. TB preventive therapy for people living with HIV: key considerations for scale-up in resource-limited settings.

    Science.gov (United States)

    Pathmanathan, I; Ahmedov, S; Pevzner, E; Anyalechi, G; Modi, S; Kirking, H; Cavanaugh, J S

    2018-06-01

    Tuberculosis (TB) is the leading cause of death for persons living with the human immunodeficiency virus (PLHIV). TB preventive therapy (TPT) works synergistically with, and independently of, antiretroviral therapy to reduce TB morbidity, mortality and incidence among PLHIV. However, although TPT is a crucial and cost-effective component of HIV care for adults and children and has been recommended as an international standard of care for over a decade, it remains highly underutilized. If we are to end the global TB epidemic, we must address the significant reservoir of tuberculous infection, especially in those, such as PLHIV, who are most likely to progress to TB disease. To do so, we must confront the pervasive perception that barriers to TPT scale-up are insurmountable in resource-limited settings. Here we review available evidence to address several commonly stated obstacles to TPT scale-up, including the need for the tuberculin skin test, limited diagnostic capacity to reliably exclude TB disease, concerns about creating drug resistance, suboptimal patient adherence to therapy, inability to monitor for and prevent adverse events, a 'one size fits all' option for TPT regimen and duration, and uncertainty about TPT use in children, adolescents, and pregnant women. We also discuss TPT delivery in the era of differentiated care for PLHIV, how best to tackle advanced planning for drug procurement and supply chain management, and how to create an enabling environment for TPT scale-up success.

  13. Facilitation of Goal-Setting and Follow-Up in an Internet Intervention for Health and Wellness

    Science.gov (United States)

    Kaipainen, Kirsikka; Mattila, Elina; Kinnunen, Marja-Liisa; Korhonen, Ilkka

    Chronic work-related stress and insufficient recovery from workload can gradually lead to problems with mental and physical health. Resources in healthcare are limited especially for preventive treatment, but low-cost support can be provided by Internet-based behavior change interventions. This paper describes the design of an Internet intervention which supports working-age people in managing and preventing stress-related health and wellness problems. The intervention is designed for early prevention and aims to motivate individuals to take responsibility for their own well-being. It allows them to choose the approach to take to address personally significant issues, while guiding them through the process. The first iteration of the intervention was evaluated with three user groups and subsequently improved based on the user experiences to be more persuasive, motivating and better suited for independent use. Goal setting and follow-up were especially enhanced, tunneled structure improved, and the threshold of use lowered.

  14. Development of a multipurpose beam foil spectroscopy set-up for the low cross-section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Gaurav [Department of Applied Physics, Delhi Technological University, New Delhi, Delhi 110042 (India); Nandi, T. [Inter University Accelerator Centre, New Delhi 110067 (India); Berry, H.G. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States); Puri, Nitin K., E-mail: nitin.phy@dce.edu [Department of Applied Physics, Delhi Technological University, New Delhi, Delhi 110042 (India)

    2016-08-01

    A multipurpose facility for low cross section measurements has been developed at Inter University Accelerator Centre, New Delhi, India. The facility consists of a multipurpose miniature chamber equipped with 1 m focal length normal incidence Monochromator and charge coupled device based detection system which has been aligned to realize the best resolution of the spectrometer. The chamber in this facility collects radiation 100 times more efficiently from the older system, without using any extra focusing mirror assembly. It is ensured to have the provision of mounting an X-ray detector and the spectrometer transverse to the beam direction simultaneously in the same chamber. The atomic spectroscopic studies can be performed by interaction of ions beams with both thin foil and gas targets. Provision for using photomultiplier tube instead of charge coupled device, is employed in the system depending on the condition of the source strength or other detection issues. We observed the essence of a very weak atomic phenomenon, a triply excited autoionizing forbidden transition, using the above facility to demonstrate its capability for measuring such low cross section phenomena. The present developed facility covers a large spectroscopic region from X-rays to the near infrared (0.1–10,000 Å).

  15. Set-up with electrostatic analyzer for mass spectrometers

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Sysoev, A.A.; Samsonov, G.A.

    1977-01-01

    An attachment with an electrostatic analyzer that enables to implement a double focusing of ion beams when used in conjunction with a magnetic analyzer, is suggested. Used as the electrostatic analyzer is a cylindrical capacitor placed in a vacuum chamber. Apart from this, the attachment includes a vacuum pump, a nitrogen trap, a battery supply unit, one-beam ion receivers and a bellows inlet for capacitor adjustment. All assemblies and parts of the attachment are made of stainless steel. The test of a combined operation of the mass-spactrometer and the attachment indicate that the use of the attachment enables the utilization of sources which form ion beams with an energy dispersion of up to 1.5%, the mass-spectrometer resolving power being unchanged

  16. Latch-up and radiation integrated circuit--LURIC: a test chip for CMOS latch-up investigation

    International Nuclear Information System (INIS)

    Estreich, D.B.

    1978-11-01

    A CMOS integrated circuit test chip (Latch-Up and Radiation Integrated Circuit--LURIC) designed for CMOS latch-up and radiation effects research is described. The purpose of LURIC is (a) to provide information on the physics of CMOS latch-up, (b) to study the layout dependence of CMOS latch-up, and (c) to provide special latch-up test structures for the development and verification of a latch-up model. Many devices and test patterns on LURIC are also well suited for radiation effects studies. LURIC contains 86 devices and related test structures. A 12-layer mask set allows both metal gate CMOS and silicon gate ELA (Extended Linear Array) CMOS to be fabricated. Six categories of test devices and related test structures are included. These are (a) the CD4007 metal gate CMOS IC with auxiliary test structures, (b) ELA CMOS cells, (c) field-aided lateral pnp transistors, (d) p-well and substrate spreading resistance test structures, (e) latch-up test structures (simplified symmetrical latch-up paths), and (f) support test patterns (e.g., MOS capacitors, p + n diodes, MOS test transistors, van der Pauw and Kelvin contact resistance test patterns, etc.). A standard probe pattern array has been used on all twenty-four subchips for testing convenience

  17. Development of Problem Sets for K-12 and Engineering on Pharmaceutical Particulate Systems

    Science.gov (United States)

    Savelski, Mariano J.; Slater, C. Stewart; Del Vecchio, Christopher A.; Kosteleski, Adrian J.; Wilson, Sarah A.

    2010-01-01

    Educational problem sets have been developed on structured organic particulate systems (SOPS) used in pharmaceutical technology. The sets present topics such as particle properties and powder flow and can be integrated into K-12 and college-level curricula. The materials educate students in specific areas of pharmaceutical particulate processing,…

  18. 77 FR 47797 - Federal Acquisition Regulation; Small Business Set Asides for Research and Development Contracts

    Science.gov (United States)

    2012-08-10

    ... Acquisition Regulation; Small Business Set Asides for Research and Development Contracts AGENCY: Department of... when the market research conducted in accordance with FAR part 10 indicates there are small businesses... officer can proceed with a small business set-aside for research and development. FAR 19.502-2(b...

  19. Identifying prognostic features by bottom-up approach and correlating to drug repositioning.

    Directory of Open Access Journals (Sweden)

    Wei Li

    Full Text Available Traditionally top-down method was used to identify prognostic features in cancer research. That is to say, differentially expressed genes usually in cancer versus normal were identified to see if they possess survival prediction power. The problem is that prognostic features identified from one set of patient samples can rarely be transferred to other datasets. We apply bottom-up approach in this study: survival correlated or clinical stage correlated genes were selected first and prioritized by their network topology additionally, then a small set of features can be used as a prognostic signature.Gene expression profiles of a cohort of 221 hepatocellular carcinoma (HCC patients were used as a training set, 'bottom-up' approach was applied to discover gene-expression signatures associated with survival in both tumor and adjacent non-tumor tissues, and compared with 'top-down' approach. The results were validated in a second cohort of 82 patients which was used as a testing set.Two sets of gene signatures separately identified in tumor and adjacent non-tumor tissues by bottom-up approach were developed in the training cohort. These two signatures were associated with overall survival times of HCC patients and the robustness of each was validated in the testing set, and each predictive performance was better than gene expression signatures reported previously. Moreover, genes in these two prognosis signature gave some indications for drug-repositioning on HCC. Some approved drugs targeting these markers have the alternative indications on hepatocellular carcinoma.Using the bottom-up approach, we have developed two prognostic gene signatures with a limited number of genes that associated with overall survival times of patients with HCC. Furthermore, prognostic markers in these two signatures have the potential to be therapeutic targets.

  20. Development of a test set for adjustment of residential furnaces and boilers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    A program was undertaken to design and develop a portable test set for simplified field adjustment of residential furnaces and boilers to achieve peak operating efficiency. Advanced technology was applied to provide continuous analysis of flue gases and the display of temperature, oxygen concentrations, smoke value and furnace efficiency. Prototype models were constructed and delivered to Brookhaven National Laboratory for further testing. A survey of furnace dealers was conducted, and a commercialization plan was developed based on survey responses and the status of the equipment developed under the program. Goals for a marketable test set and development steps to achieve a projected energy savings were determined and recommended. Recommendations for specific areas of further development are included.

  1. Intervene: a tool for intersection and visualization of multiple gene or genomic region sets.

    Science.gov (United States)

    Khan, Aziz; Mathelier, Anthony

    2017-05-31

    A common task for scientists relies on comparing lists of genes or genomic regions derived from high-throughput sequencing experiments. While several tools exist to intersect and visualize sets of genes, similar tools dedicated to the visualization of genomic region sets are currently limited. To address this gap, we have developed the Intervene tool, which provides an easy and automated interface for the effective intersection and visualization of genomic region or list sets, thus facilitating their analysis and interpretation. Intervene contains three modules: venn to generate Venn diagrams of up to six sets, upset to generate UpSet plots of multiple sets, and pairwise to compute and visualize intersections of multiple sets as clustered heat maps. Intervene, and its interactive web ShinyApp companion, generate publication-quality figures for the interpretation of genomic region and list sets. Intervene and its web application companion provide an easy command line and an interactive web interface to compute intersections of multiple genomic and list sets. They have the capacity to plot intersections using easy-to-interpret visual approaches. Intervene is developed and designed to meet the needs of both computer scientists and biologists. The source code is freely available at https://bitbucket.org/CBGR/intervene , with the web application available at https://asntech.shinyapps.io/intervene .

  2. Use of the Bayley Scales of Infant and Toddler Development, Third Edition, to Assess Developmental Outcome in Infants and Young Children in an Urban Setting in South Africa

    OpenAIRE

    Ballot, Daynia E.; Ramdin, Tanusha; Rakotsoane, David; Agaba, Faustine; Davies, Victor A.; Chirwa, Tobias; Cooper, Peter A.

    2017-01-01

    Background. The Bayley Scales of Infant and Toddler Development (III) is a tool developed in a Western setting. Aim. To evaluate the development of a group of inner city children in South Africa with no neonatal risk factors using the Bayley Scales of Infant and Toddler Development (III), to determine an appropriate cut-off to define developmental delay, and to establish variation in scores done in the same children before and after one year of age. Methods. Cohort follow-up study. Results. 7...

  3. Prompt gamma analysis of chlorine in concrete for corrosion study

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2006-02-15

    Measurement of chlorine in concrete is very important for studying of corrosion of reinforcing steel in concrete. Corrosion of reinforcing steel is primarily ascribed to the penetration of chloride ions to the steel surface. Preventive measures for avoiding concrete structure reinforcement corrosion requires monitoring the chloride ion concentration in concrete so that its concentration does not exceed a threshold limit to initiate reinforcement concrete corrosion. An accelerator based prompt gamma neutron activation analysis (PGNAA) setup has been developed for non-destructive analysis of elemental composition of concrete samples. The setup has been used to measure chlorine concentration in concrete samples over a 1-3 wt% concentration range. Although a strong interference has been observed between the chlorine {gamma}-rays and calcium {gamma}-rays from concrete, the chlorine concentration in concrete samples has been successfully measured using the 1.164 and 7.643 MeV chlorine {gamma}-rays. The experimental data were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the experimental data and results of Monte Carlo simulations. The study has demonstrated the successful use of the accelerator-based PGNAA setup in non-destructive analysis of chlorine in concrete samples.

  4. Measures for instantaneous voltage drop and UPS market (activities of individual companies). Technology development of large-capacity UPS system; Shunji den`atsu teika taisaku to UPS shijo. Daiyoryo UPS system no gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Motoki, Y. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1998-07-01

    This paper describes development of large-capacity UPS (uninterruptive power source) for large-capacity computer systems by Fuji Electric. This UPS is composed of a rectifier, inverter, transformer, and ac filter. The rectifier and inverter are composed of the same IGBT power modules. The IGBT power module has an integrated structure consisting of IGBT, gate driving circuit, snubber circuit, electrolytic capacitor, cooling fin, and fuse. Downsizing of snubber circuit and improvement of mounting efficiency were realized by developing a large current substrate with small wiring inductance. Advanced input/output performance and control characteristics of USP were realized by the digital control using RISC and DSP of high-speed processor. For the inverter control algorithm, PWM pulse can be calculated using parameters derived from the state equation of the main circuit constants. The output voltage distortion factor less than 5% was realized at the nonlinear load of 100%. The UPS systems in the out-sourcing business and large-scale business center are illustrated as examples. 6 figs.

  5. China prices up, ahead of major rail maintenance

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    An update is given in China's coal industry. IN a move to keep more of its coal in China, a coal export quota of 38 mt has been set-up. Part. time closure of the Daqin railway line for maintenance is affecting prices. Development projects and mine safety are discussed. 1 photo.

  6. Does mode of follow-up influence contraceptive use after medical abortion in a low-resource setting? Secondary outcome analysis of a non-inferiority randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Mandira Paul

    2016-10-01

    Full Text Available Abstract Background Post-abortion contraceptive use in India is low and the use of modern methods of contraception is rare, especially in rural areas. This study primarily compares contraceptive use among women whose abortion outcome was assessed in-clinic with women who assessed their abortion outcome at home, in a low-resource, primary health care setting. Moreover, it investigates how background characteristics and abortion service provision influences contraceptive use post-abortion. Methods A randomized controlled, non-inferiority, trial (RCT compared clinic follow-up with home-assessment of abortion outcome at 2 weeks post-abortion. Additionally, contraceptive-use at 3 months post-abortion was investigated through a cross-sectional follow-up interview with a largely urban sub-sample of women from the RCT. Women seeking abortion with a gestational age of up to 9 weeks and who agreed to a 2-week follow-up were included (n = 731. Women with known contraindications to medical abortions, Hb < 85 mg/l and aged below 18 were excluded. Data were collected between April 2013 and August 2014 in six primary health-care clinics in Rajasthan. A computerised random number generator created the randomisation sequence (1:1 in blocks of six. Contraceptive use was measured at 2 weeks among women successfully followed-up (n = 623 and 3 months in the sub-set of women who were included if they were recruited at one of the urban study sites, owned a phone and agreed to a 3-month follow-up (n = 114. Results There were no differences between contraceptive use and continuation between study groups at 3 months (76 % clinic follow-up, 77 % home-assessment, however women in the clinic follow-up group were most likely to adopt a contraceptive method at 2 weeks (62 ± 12 %, while women in the home-assessment group were most likely to adopt a method after next menstruation (60 ± 13 %. Fifty-two per cent of women who initiated a

  7. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Sung Jiun

    2014-01-01

    The V and V method has been utilized for this safety critical software, while SRGM has difficulties because of lack of failure occurrence data on developing phase. For the safety critical software, however, failure data cannot be gathered after installation in real plant when we consider the severe consequence. Therefore, to complement the V and V method, the test-based method need to be developed. Some studies on test-based reliability quantification method for safety critical software have been conducted in nuclear field. These studies provide useful guidance on generating test sets. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values. The other problem is number of tests needed. To satisfy a target reliability with reasonable confidence level, very large number of test sets are required. Development of this number of test sets is a herculean

  8. Development of a Goal Setting Process and Instrumentation for Teachers and Principals.

    Science.gov (United States)

    Minix, Nancy; And Others

    A pilot program, the Career Ladder Plan, was developed in Kentucky to evaluate a teacher's performance in terms of professional growth and development and professional leadership/initiative based on that teacher's performance on a setting/goal attainment process. Goals jointly selected by the teacher and his/her principal must contribute to school…

  9. Development and validation of an Argentine set of facial expressions of emotion.

    Science.gov (United States)

    Vaiman, Marcelo; Wagner, Mónica Anna; Caicedo, Estefanía; Pereno, Germán Leandro

    2017-02-01

    Pictures of facial expressions of emotion are used in a wide range of experiments. The last decade has seen an increase in the number of studies presenting local sets of emotion stimuli. However, only a few existing sets contain pictures of Latin Americans, despite the growing attention emotion research is receiving in this region. Here we present the development and validation of the Universidad Nacional de Cordoba, Expresiones de Emociones Faciales (UNCEEF), a Facial Action Coding System (FACS)-verified set of pictures of Argentineans expressing the six basic emotions, plus neutral expressions. FACS scores, recognition rates, Hu scores, and discrimination indices are reported. Evidence of convergent validity was obtained using the Pictures of Facial Affect in an Argentine sample. However, recognition accuracy was greater for UNCEEF. The importance of local sets of emotion pictures is discussed.

  10. Antenatal drug consumption: the burden of self-medication in a developing world setting.

    Science.gov (United States)

    Adanikin, Abiodun Idowu; Awoleke, Jacob Olumuyiwa

    2017-07-01

    This institutional-based cross-sectional study examines the burden of self-medication during pregnancy in a middle-income country setting and the impact on fetal wellbeing. Using a blend of open-ended and indication-oriented questionnaires, 346 pregnant women at term were interviewed about their pregnancy complaints and drug intake. Inferential statistical data analysis was employed with level of significance (α) set at 0.05. Excluding routine supplements and vaccinations, 251 (72.5%) women used medicines, of whom 79 (31.5%) had self-medicated. Consuming drugs without prescription was associated with increased US Food & Drug Administration (FDA) risk category (χ 2  = 8.375; P = 0.015). There is therefore a need to scale up efforts towards educating women about the dangers of self-medication, while also introducing effective restrictive policies on over-the-counter drug sales.

  11. Tools and approaches for simplifying serious games development in educational settings

    OpenAIRE

    Calvo, Antonio; Rotaru, Dan C.; Freire, Manuel; Fernandez-Manjon, Baltasar

    2016-01-01

    Serious Games can benefit from the commercial video games industry by taking advantage of current development tools. However, the economics and requirements of serious games and commercial games are very different. In this paper, we describe the factors that impact the total cost of ownership of serious games used in educational settings, review the specific requirements of games used as learning material, and analyze the different development tools available in the industry highlighting thei...

  12. Simulations and field tests of a reactor coolant pump emergency start-up by means of remote gas units

    International Nuclear Information System (INIS)

    Omahen, P.; Gubina, F.

    1992-01-01

    The problem of the reactor coolant pump start-up in case of emergency by means of remote gas power plant units was analyzed. In this paper a simulation model is developed which enabled a detailed simulation of the transient process occurring at the start-up. The start-up of the RCP motor set was simulated in case of available one and two gas units. The field tests were performed and the measured variable values complied well with the simulation results. Two gas units have been determined as a safe start-up scheme of the RCP motor set considering for safety reasons accepted busbars and motor protection settings. A derived model for deep rotor bars was experimentally confirmed as effective means for the RCP motor set start-up transient simulation. Start-up procedures have been designed and adopted to the safety procedures of the Nuclear Power Plant Krsko

  13. Developing an assessment of fire-setting to guide treatment in secure settings: the St Andrew's Fire and Arson Risk Instrument (SAFARI).

    Science.gov (United States)

    Long, Clive G; Banyard, Ellen; Fulton, Barbara; Hollin, Clive R

    2014-09-01

    Arson and fire-setting are highly prevalent among patients in secure psychiatric settings but there is an absence of valid and reliable assessment instruments and no evidence of a significant approach to intervention. To develop a semi-structured interview assessment specifically for fire-setting to augment structured assessments of risk and need. The extant literature was used to frame interview questions relating to the antecedents, behaviour and consequences necessary to formulate a functional analysis. Questions also covered readiness to change, fire-setting self-efficacy, the probability of future fire-setting, barriers to change, and understanding of fire-setting behaviour. The assessment concludes with indications for assessment and a treatment action plan. The inventory was piloted with a sample of women in secure care and was assessed for comprehensibility, reliability and validity. Staff rated the St Andrews Fire and Risk Instrument (SAFARI) as acceptable to patients and easy to administer. SAFARI was found to be comprehensible by over 95% of the general population, to have good acceptance, high internal reliability, substantial test-retest reliability and validity. SAFARI helps to provide a clear explanation of fire-setting in terms of the complex interplay of antecedents and consequences and facilitates the design of an individually tailored treatment programme in sympathy with a cognitive-behavioural approach. Further studies are needed to verify the reliability and validity of SAFARI with male populations and across settings.

  14. Bracing up for a global nuclear renaissance

    International Nuclear Information System (INIS)

    Autebert, Remy

    2008-01-01

    The nuclear new build market is dynamic: the nuclear renaissance is here. The challenge facing today the nuclear industry is to meet this strong demand: design and build new reactors..... and ensure an adequate fuel supply for the existing reactors and the new ones. AREVA is getting ready to meet those needs. To answer in the best possible way the call of several new customers, and to make the necessary investments AREVA has made the choice of complementing its own strength with new alliances. When it was created, AREVA has set a new model: an integrated group capable of supplying all parts of the nuclear cycle, from Uranium mining to reactor design construction and servicing, and then up to used fuel management and recycling. This merger of reactor activities and fuel cycle services has proved successful. Focused acquisitions have further strengthened our own capabilities. In addition, AREVA has set-up several alliances to further develop the nuclear market. In the United States, AREVA joined forces with the US utility Constellation to create Uni Star to promoting the EPR. Today, several US utilities are choosing the AREVA's US-EPR. They will benefit from the experience gained in licensing and building the EPR in Finland, in France and soon in China. And they will benefit of course from the unique features of the EPR: easier maintenance, shorter outage, enhanced safety. Willing to meet the growing demand of countries launching a new nuclear program, AREVA set up an alliance with MHI to design a mid-size reactor, ATEMEA 1. Such an alliance allows to speed-up time to market of this new product, which will offer the latest available technologies. In the fuel cycle, AREVA has also developed acquisitions and alliances. As an example, thanks to such an alliance, the new enrichment plant GB-2, could get access to the most efficient centrifugation process. In this fast growing global market, at AREVA we believe into the value of collaboration and partnership to best serve

  15. Know how to teach me: Setting up an inclusive classroom : A study on preparing teachers for inclusive education in India

    NARCIS (Netherlands)

    Srivastava, Meenakshi

    2016-01-01

    Education For All has been an important objective in the Millennium development goals which were set internationally. The goals aim at making all children attending school irrespective of gender, ethnicity, socioeconomic status or special educational needs (SEN). In developing countries providing

  16. Setting Up Decision-Making Tools toward a Quality-Oriented Participatory Maize Breeding Program

    Science.gov (United States)

    Alves, Mara L.; Brites, Cláudia; Paulo, Manuel; Carbas, Bruna; Belo, Maria; Mendes-Moreira, Pedro M. R.; Brites, Carla; Bronze, Maria do Rosário; Gunjača, Jerko; Šatović, Zlatko; Vaz Patto, Maria C.

    2017-01-01

    Previous studies have reported promising differences in the quality of kernels from farmers' maize populations collected in a Portuguese region known to produce maize-based bread. However, several limitations have been identified in the previous characterizations of those populations, such as a limited set of quality traits accessed and a missing accurate agronomic performance evaluation. The objectives of this study were to perform a more detailed quality characterization of Portuguese farmers' maize populations; to estimate their agronomic performance in a broader range of environments; and to integrate quality, agronomic, and molecular data in the setting up of decision-making tools for the establishment of a quality-oriented participatory maize breeding program. Sixteen farmers' maize populations, together with 10 other maize populations chosen for comparison purposes, were multiplied in a common-garden experiment for quality evaluation. Flour obtained from each population was used to study kernel composition (protein, fat, fiber), flour's pasting behavior, and bioactive compound levels (carotenoids, tocopherols, phenolic compounds). These maize populations were evaluated for grain yield and ear weight in nine locations across Portugal; the populations' adaptability and stability were evaluated using additive main effects and multiplication interaction (AMMI) model analysis. The phenotypic characterization of each population was complemented with a molecular characterization, in which 30 individuals per population were genotyped with 20 microsatellites. Almost all farmers' populations were clustered into the same quality-group characterized by high levels of protein and fiber, low levels of carotenoids, volatile aldehydes, α- and δ-tocopherols, and breakdown viscosity. Within this quality-group, variability on particular quality traits (color and some bioactive compounds) could still be found. Regarding the agronomic performance, farmers' maize populations

  17. Setting Up Decision-Making Tools toward a Quality-Oriented Participatory Maize Breeding Program

    Directory of Open Access Journals (Sweden)

    Mara L. Alves

    2017-12-01

    Full Text Available Previous studies have reported promising differences in the quality of kernels from farmers' maize populations collected in a Portuguese region known to produce maize-based bread. However, several limitations have been identified in the previous characterizations of those populations, such as a limited set of quality traits accessed and a missing accurate agronomic performance evaluation. The objectives of this study were to perform a more detailed quality characterization of Portuguese farmers' maize populations; to estimate their agronomic performance in a broader range of environments; and to integrate quality, agronomic, and molecular data in the setting up of decision-making tools for the establishment of a quality-oriented participatory maize breeding program. Sixteen farmers' maize populations, together with 10 other maize populations chosen for comparison purposes, were multiplied in a common-garden experiment for quality evaluation. Flour obtained from each population was used to study kernel composition (protein, fat, fiber, flour's pasting behavior, and bioactive compound levels (carotenoids, tocopherols, phenolic compounds. These maize populations were evaluated for grain yield and ear weight in nine locations across Portugal; the populations' adaptability and stability were evaluated using additive main effects and multiplication interaction (AMMI model analysis. The phenotypic characterization of each population was complemented with a molecular characterization, in which 30 individuals per population were genotyped with 20 microsatellites. Almost all farmers' populations were clustered into the same quality-group characterized by high levels of protein and fiber, low levels of carotenoids, volatile aldehydes, α- and δ-tocopherols, and breakdown viscosity. Within this quality-group, variability on particular quality traits (color and some bioactive compounds could still be found. Regarding the agronomic performance, farmers

  18. Applications of Monte Carlo simulations of gamma-ray spectra

    International Nuclear Information System (INIS)

    Clark, D.D.

    1995-01-01

    A short, convenient computer program based on the Monte Carlo method that was developed to generate simulated gamma-ray spectra has been found to have useful applications in research and teaching. In research, we use it to predict spectra in neutron activation analysis (NAA), particularly in prompt gamma-ray NAA (PGNAA). In teaching, it is used to illustrate the dependence of detector response functions on the nature of gamma-ray interactions, the incident gamma-ray energy, and detector geometry

  19. Facilitating responsible gambling: the relative effectiveness of education-based animation and monetary limit setting pop-up messages among electronic gaming machine players.

    Science.gov (United States)

    Wohl, Michael J A; Gainsbury, Sally; Stewart, Melissa J; Sztainert, Travis

    2013-12-01

    Although most gamblers set a monetary limit on their play, many exceed this limit--an antecedent of problematic gambling. Responsible gambling tools may assist players to gamble within their means. Historically, however, the impact of such tools has been assessed in isolation. In the current research, two responsible gambling tools that target adherence to a monetary limit were assessed among 72 electronic gaming machine (EGM) players. Participants watched an educational animation explaining how EGMs work (or a neutral video) and then played an EGM in a virtual reality environment. All participants were asked to set a monetary limit on their play, but only half were reminded when that limit was reached. Results showed that both the animation and pop-up limit reminder helped gamblers stay within their preset monetary limit; however, an interaction qualified these main effects. Among participants who did not experience the pop-up reminder, those who watched the animation stayed within their preset monetary limits more than those who did not watch the animation. For those who were reminded of their limit, however, there was no difference in limit adherence between those who watched the animation and those who did not watch the animation. From a responsible gambling perspective, the current study suggests that there is no additive effect of exposure to both responsible gambling tools. Therefore, for minimal disruption in play, a pop-up message reminding gamblers of their preset monetary limit might be preferred over the lengthier educational animation.

  20. The potential impact of the tension of the pelvic muscles on set-up errors in radiotherapy for pelvic malignancies

    International Nuclear Information System (INIS)

    Bujko, Krzysztof; Czuchraniuk, Piotr; Zolciak, Agnieszka; Kukolowicz, Pawel; Kepka, Lucyna; Bielik, Agnieszka

    2004-01-01

    The purpose of the study reported here was to evaluate the potential impact of the tension of pelvic muscles on set-up errors. Twenty-nine consecutive patients with rectal cancer were included. The treatment simulation of the lateral beam in prone position was performed twice-with relaxed and next with maximally tense pelvic muscles. During the second simulation, the couch was moved so as to align the centre of the beam with the actual position of the skin mark tattooed during the first simulation. The bony landmarks on both images of corresponding lateral fields were matched. The beam's centre displacement and the rotation were measured using the beam image taken in relaxed position as a reference. The absolute values were used in calculation of the mean. For the anterior-posterior direction, the mean value of displacements was 15.3 mm, standard deviation (SD) 6.9 mm and the maximal value 37 mm. For the cranial-caudal direction, the mean value was 4.4 mm, SD 4 mm and the maximal value 17 mm. The mean rotation of the pelvis was 5.3 degrees, SD 2.4 degrees and maximal rotation 11 degrees. The majority of displacements were in the posterior (86%) and caudal (55%) directions. The majority of rotations were clockwise (76%). It was shown that pelvic muscle tension was the reason for anal verge displacements and mispositionings of the shielding block. This results in set-up inaccuracy, especially in the anterior-posterior direction, shielding block mispositioning and anal verge displacement