WorldWideScience

Sample records for peripheral grip member

  1. Deficits of anticipatory grip force control after damage to peripheral and central sensorimotor systems.

    Science.gov (United States)

    Hermsdörfer, Joachim; Hagl, Elke; Nowak, Dennis A

    2004-11-01

    Healthy subjects adjust their grip force economically to the weight of a hand-held object. In addition, inertial loads, which arise from arm movements with the grasped object, are anticipated by parallel grip force modulations. Internal forward models have been proposed to predict the consequences of voluntary movements. Anesthesia of the fingers impairs grip force economy but the feedforward character of the grip force/load coupling is preserved. To further analyze the role of sensory input for internal forward models and to characterize the consequences of central nervous system damage for anticipatory grip force control, we measured grip force behavior in neurological patients. We tested a group of stroke patients with varying degrees of impaired fine motor control and sensory loss, a single patient with complete and permanent differentation from all tactile and proprioceptive input, and a group of patients with amyotrophic lateral sclerosis (ALS) that exclusively impairs the motor system without affecting sensory modalities. Increased grip forces were a common finding in all patients. Sensory deficits were a strong but not the only predictor of impaired grip force economy. The feedforward mode of grip force control was typically preserved in the stroke patients despite their central sensory deficits, but was severely disturbed in the patient with peripheral sensory deafferentation and in a minority of stroke patients. Moderate deficits of feedforward control were also obvious in ALS patients. Thus, the function of the internal forward model and the precision of grip force production may depend on a complex anatomical and functional network of sensory and motor structures and their interaction in time and space.

  2. Thimble grip fuel assembly handling tool

    International Nuclear Information System (INIS)

    Salton, R.B.; Hornak, L.P.; Marshall, J.R.; Meuschke, R.E.

    1989-01-01

    This patent describes an apparatus for lifting a fuel assembly of a nuclear reactor. The fuel assembly consists of a top nozzle and control rod guide tubes. The apparatus having a gripping means comprised of: a life plate, an actuating plate having a plurality of apertures, the actuating plate disposed in spaced relationship below the lift plate and vertically movable relative thereto; gripping members operably associated with the lift and actuating plates, the gripping members comprising: (a) a vertical rod fixedly secured near its top end to the lift plate and projecting downward therefrom through an associated aperture in the actuating plate, the rod having a first frustoconical surface formed near its lower end, (b) a generally cylindrical, elastically deformable vertical sleeve having a bore therethrough with a first inner diameter, the sleeve having a first bevelled inside surface near the top end and a second bevelled inside surface at the bottom end of the sleeve, and (c) a vertical gripper actuator disposed about the rod

  3. Reference Values of Grip Strength, Prevalence of Low Grip Strength, and Factors Affecting Grip Strength Values in Chinese Adults.

    Science.gov (United States)

    Yu, Ruby; Ong, Sherlin; Cheung, Osbert; Leung, Jason; Woo, Jean

    2017-06-01

    The objectives of this study were to update the reference values of grip strength, to estimate the prevalence of low grip strength, and to examine the impact of different aspects of measurement protocol on grip strength values in Chinese adults. A cross-sectional survey of Chinese men (n = 714) and women (n = 4014) aged 18-102 years was undertaken in different community settings in Hong Kong. Grip strength was measured with a digital dynamometer (TKK 5401 Grip-D; Takei, Niigata, Japan). Low grip strength was defined as grip strength 2 standard deviations or more below the mean for young adults. The effects of measurement protocol on grip strength values were examined in a subsample of 45 men and women with repeated measures of grip strength taken with a hydraulic dynamometer (Baseline; Fabrication Enterprises Inc, Irvington, NY), using pair t-tests, intraclass correlation coefficient, and Bland and Altman plots. Grip strength was greater among men than among women (P values than the Baseline hydraulic dynamometer (P values were also observed when the measurement was performed with the elbow extended in a standing position, compared with that with the elbow flexed at 90° in a sitting position, using the same dynamometer (P values of grip strength and estimated the prevalence of low grip strength among Chinese adults spanning a wide age range. These findings might be useful for risk estimation and evaluation of interventions. However, grip strength measurements should be interpreted with caution, as grip strength values can be affected by type of dynamometer used, assessment posture, and elbow position. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  4. ANALYSIS OF POWER GRIP AND PINCH GRIP AMONG HEALTH CARE PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Zakariya M P

    2016-02-01

    Full Text Available Background: Grip and pinch strength are commonly employed indices of strength used in hand evaluations. Pinch grip and power grip strengths are used as indices of strength in hand therapy assessments. For all professions grip strength is an important criterion to be successful in their profession. Such phenomena may be explained by differences in nature of work, working environment, and objects workers handle. Method: 200 healthy subjects, satisfying the selection criteria were included and assessed with standardized procedure for power grip and pinch grip (lateral pinch, pad-pad, and tip-tip strength. They were divided in four groups, 50 group each according to profession i.e. medical surgeons, dentist, physiotherapists and nurses. Results: The mean power grip strength shows highly significant difference between medical vs. dental (p>0.01 and medical vs. physiotherapy group (p> 0.05 .The mean lateral pinch strength shows there is highly significant difference (p< 0.001 between dental vs. nursing profession and dental vs. physiotherapy group. No significant difference among other groups. The mean pad-pad pinch strength shows there is significant difference between dental vs. nursing (p< 0.05 and dental vs physiotherapy group (p< 0.05. The mean Tip-Tip pinch strength shows there is significant difference between dental vs nursing profession(p< 0.05 and dental vs. physiotherapy(p< 0.05. No significant different among other groups. Conclusion: Surgeons have highest power grip strength followed by Nursing, Physiotherapy and Dental professionals. Dentists have the maximum pinch strength in all three positions, followed by Surgeons, Nurses and Physiotherapists. Surgeons have maximum pinch strength next to Dentists.

  5. Variability of grip kinetics during adult signature writing.

    Directory of Open Access Journals (Sweden)

    Bassma Ghali

    Full Text Available Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20 adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  6. GRIP CAMPAIGN REPORTS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Campaign Reports dataset consists of various reports filed by scientists during the GRIP campaign which took place 8/15/2010 - 9/30/2010; however, several...

  7. Road grip test in Arjeplog

    OpenAIRE

    Engström, Niclas; Andrén, Henrik; Nybacka, Mikael; Fransson, Lennart; Larsson, Roland

    2008-01-01

    The Swedish road administration sees a need to improve the road grip estimation capacity for the Swedish road system. The challenge is to find methods to measure road grip fast and reliable. There where six different system types at the tests in Arjeplog, three continuous, two system measuring road grip through deceleration and one system based on GPS and accelerometers. Two system types used air craft runway tires. The other systems used either studded winter tires or friction winter tires. ...

  8. Gripping means for fuel assemblies of nuclear reactor

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Fadeev, A.I.; Shkhian, T.G.; Vjugov, O.N.

    1980-01-01

    The proposed gripping means for fuel assemblies of a nuclear reactor comprises a housing, whereupon there is movably mounted a slider provided with longitudinally extending slots to receive gripping jaws whose tails are pivotably secured to the housing of the gripping means. On one side, the end faces of the longitudinally extending slots are slanted with respect to the longitudinal axis of the gripping means and come in contact with the teeth of the gripping jaws provided on the end which is opposite to the tail, whereby the jaws open as the slider and housing of the gripping means moves relative to each other so that the teeth are received in an internal groove provided in the head of the fuel assembly

  9. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  10. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  11. Effect of Isometric Hand Grip Exercises on Blood Flow and Placement of IV Catheters for Administration of Chemotherapy.

    Science.gov (United States)

    Ozkaraman, Ayse; Yesilbalkan, Öznur Usta

    2016-04-01

    Complications may occur in the subcutaneous or subdermal tissues during IV administration of chemotherapy related to blood flow and catheter placement. Daily isometric hand grip exercises were evaluated for their effect on blood flow in the vessels of the nondominant arm before placement of IV catheters and the success rate of IV catheter placement on the first attempt. The study focused on patients with non-Hodgkin lymphoma receiving the first and second cycles of chemotherapy. The intervention group performed daily isometric hand grip exercises before chemotherapy with peripheral catheter insertion. The control group performed routine activities only. Blood flow was measured by ultrasound in the brachial artery (BA) and brachial vein (BV) of the nondominant arm before the first (T1) and second (T2) cycles of chemotherapy. Blood flow slightly increased in the intervention group at T2 compared to T1. In the control group, blood flow decreased in the BA and did not change in the BV at T2 compared to T1. The success rate for first-attempt placement of a peripheral IV catheter was the same for the intervention and control groups.

  12. Grip Strength Survey Based on Hand Tool Usage

    Directory of Open Access Journals (Sweden)

    Erman ÇAKIT

    2016-12-01

    Full Text Available Hand grip strength is broadly used for performing tasks involving equipment in production and processing activities. Most professionals in this field rely on grip strength to perform their tasks. There were three main aims of this study: i determining various hand grip strength measurements for the group of hand tool users, ii investigating the effects of height, weight, age, hand dominance, body mass index, previous Cumulative Trauma Disorder (CTD diagnosis, and hand tool usage experience on hand grip strength, and iii comparing the obtained results with existing data for other populations. The study groups comprised 71 healthy male facility workers. The values of subjects’ ages was observed between 26 and 74 years. The data were statistically analyzed to assess the normality of data and the percentile values of grip strength. The results of this study demonstrate that there were no significance differences noted between dominant and non-dominant hands. However, there were highly significant differences between the CTD group and the other group. Hand grip strength for the dominant hand was positively correlated to height, weight, and body mass index, and negatively correlated to age and tool usage experience. Hand dominance, height, weight, body mass index, age and tool usage experience should be considered when establishing normal values for grip strength.

  13. Adjustment of gripping force by optical systems

    Science.gov (United States)

    Jalba, C. K.; Barz, C.

    2018-01-01

    With increasing automation, robotics also requires ever more intelligent solutions in the handling of various tasks. In this context, many grippers must also be re-designed. For this, they must always be adapted for different requirements. The equipment of the gripper systems with sensors should help to make the gripping process more intelligent. In order to achieve such objectives, optical systems can also be used. This work analyzes how the gripping force can be adjusted by means of an optical recognition. The result of this work is the creation of a connection between optical recognition, tolerances, gripping force and real-time control. In this way, algorithms can be created, with the aid of which robot grippers as well as other gripping systems become more intelligent.

  14. G×E Interaction Influences Trajectories of Hand Grip Strength

    DEFF Research Database (Denmark)

    Petersen, Inge; Pedersen, Nancy L; Rantanen, Taina

    2016-01-01

    Age-related decline in grip strength predicts later life disability, frailty, lower well-being and cognitive change. While grip strength is heritable, genetic influence on change in grip strength has been relatively ignored, with non-shared environmental influence identified as the primary contri...

  15. ASSESSMENT OF GRIP FORCE CONTROL IN PATIENTS WITH MUSCULAR DYSTROPHY

    Directory of Open Access Journals (Sweden)

    Gregorij Kurillo

    2004-12-01

    Full Text Available Background. The majority of hand functionality tests are based on qualitative assessment which largely depends on the experience of the therapist. Computer-assisted methods can provide more objective and accurate measurements of the grip force and other parameters related to grasping.Methods. We analysed the grip force control in 12 patients with muscular dystrophy using the tracking system developed. The system consists of a grip-measuring device with endobjects assessing the force applied in different grips. The device was used as input to a tracking task where the patient applied the grip force according to the visual feedback from the computer screen. Each patient performed two tasks which consisted of tracking a ramp and sinus target.Results. We analysed the maximal grip force as assessed in the ramp task and the tracking accuracy of the sinus task. The results are compared among five different grips (cylindrical, lateral, palmar, pinch and spherical grip, applied with dominant and non-dominant hand. The results show no significant difference in tracking accuracy between the dominant and non-dominant hand.Conclusions. The results obtained in tracking the ramp target showed that the method could be used for the assessment of the muscle fatigue, providing quantitative information on muscle capacity. The results of the sinus-tracking task showed that the method can evaluate the grip force control in different types of grips, providing information on hand dexterity, muscle activation patterns or tremor.

  16. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.; Delp, Edward J.; Wong, Ping W.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  17. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 £ 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  18. Cytogenetic effects of ionizing radiation in peripheral lymphocytes of ISS crew members

    Science.gov (United States)

    Johannes, Christian; Goedecke, Wolfgang; Antonopoulos, Alexandra; Obe, Günter; Horstmann, Markus

    High energy radiation is a major risk factor in manned space missions. Astronauts and cosmonauts are exposed to ionising radiations of cosmic and solar origin, while on the Earth's surface people are well protected by the atmosphere and a deflecting magnetic field. There are now data available describing the dose and the quality of ionising radiation on-board of the International Space Station (ISS). The effect of the increased radiation dose on mutation rates of ISS crew members are hard to predict. Therefore, direct measurements of mutation rates are required.The analysis of chromosomal aberrations in peripheral blood lymphocytes is a well established method to measure radiation-induced mutations. We present data of chromosome aberration analyses from lymphocyte metaphase spreads of ISS crew members participating in short term (10-14 days) or long term (6 months) missions. From each subject we received two blood samples. The first sample was drawn about 10 days before launch and a second sample was drawn within 3 days after return from their flights. From lymphocyte cultures metaphase plates were prepared on glass slides. Metaphases were Giemsa stained or hybridised using multicolour FISH probes. All types of chromosome changes were scored in pre-flight and post-flight blood samples and the mutation rates were compared. Results obtained in chromosomal studies on long-term flight crew members showed pronounced inter-individual differences in the response to cosmic radiation exposure. Overall significant elevations of typical radiation induced aberrations, i.e., dicentric chromosomes and reciprocal translocations have been observed in long-term crew members. Our data indicate no elevation of mutation rates due to short-term stays on-board the ISS.

  19. Systems and Methods for Gravity-Independent Gripping and Drilling

    Science.gov (United States)

    Parness, Aaron (Inventor); Frost, Matthew A. (Inventor); Thatte, Nitish (Inventor); King, Jonathan P. (Inventor)

    2016-01-01

    Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

  20. Analysis of spontaneous and bleomycin-induced chromosome damage in peripheral lymphocytes of long-haul aircrew members from Argentina

    International Nuclear Information System (INIS)

    Bolzan, Alejandro D.; Bianchi, Martha S.; Gimenez, Esteban M.; Flaque, Maria C. Diaz; Ciancio, Vicente R.

    2008-01-01

    Spontaneous and bleomycin (BLM)-induced chromosomal aberrations in G0 and G2 stages of the cell cycle have been analyzed in peripheral lymphocytes of 21 long-haul aircrew members from Argentina in order to assess BLM-induced clastogenesis as a first approach to determine the DNA repair capacity and thereby the susceptibility to environmental cancers in aircrew. The possibility that occupational exposure of flight personnel to cosmic radiation can induce an adaptive response in their peripheral lymphocytes that can be detected by a subsequent in vitro treatment with BLM was also investigated. For comparison, aberrations were also scored in the lymphocytes of 15 healthy volunteers matched by age, health, sex, drinking and smoking habits to the flight personnel group. Aircrew exhibited a higher frequency of spontaneous dicentrics and ring chromosomes than the control population (p 0.05). However, the aircrew sampled population was almost two times more sensitive to BLM G0 clastogenic effects than controls (p < 0.05). Therefore, our data suggest that chronic exposure of aircrew to cosmic radiation increases the in vitro chromosomal sensitivity of their peripheral lymphocytes to BLM (at least in the G0 stage of the cell cycle), and that occupational exposure of flight personnel to cosmic radiation does not induce an adaptive response to this radiomimetic compound. Our results justify further studies aimed at determine if those aircrew members hypersensitive to BLM are more prone to develop environmental cancer than BLM-insensitive individuals

  1. Study on the collision-mechanical properties of tomatoes gripped by ...

    African Journals Online (AJOL)

    The data of collision-mechanical property of tomatoes gripped by robot fingers are important for the gripping control of tomato harvesting robot. In the study, tests of controlling the fingers to grip tomatoes were conducted to ascertain the effects of input current, motor speed and impact positions on the impact force of fingers ...

  2. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP DC-8 Navigation and Housekeeping Data contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The major goal was...

  3. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    Science.gov (United States)

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  4. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  5. Alteration in Peripheral Muscle Strength among Overweight and Obese Individuals: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Vikram Mohan

    2017-04-01

    Full Text Available Peripheral muscle dysfunction in Overweight (OW and Obesity (OB leads to fatigue and activity limitations. However, there are contradictory views regarding the exact level with regard to hand grip and quadriceps muscle strength in OW and OB. The main objective of the present systematic review was to synthesize the literature for the strength part of the hand grip and quadriceps muscle strength among OW and OB. Literature search of Scopus, EBSCO and PubMed databases from 01.01.2004 to 30.06.2016, was performed. We set our search strategy using the terms “overweight OR obesity” AND “muscle strength” AND “grip OR quadriceps”. Two reviewers administered established eligible criteria and extracted the data. Strengthening the Reporting of Observational studies in Epidemiology (STROBE was used to assess the risk of bias. Sixteen articles which were included identified Handgrip Strength (HGS, shoulder flexor, elbow flexor and knee extensor were found to be altered. There were consistent results with an increase in quadriceps muscle strength, whereas differed results were found in hand grip to increase and decrease in muscle strength in the presence of OW and OB. It is concluded that HGS appeared to be diversified with findings of increased and decrease strength, whereas regarding the quadriceps muscles, the findings were homogeneous.

  6. Improvement of handle grip using reverse engineering, CAE and Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Stoklasek Pavel

    2016-01-01

    Full Text Available The overwhelming majority of manual operations is even nowadays performed by using manual hand tools. These tools can be divided into 2 groups – hand tools designed for general use or a single-purpose hand tools for special operations. Tool described in this paper is used in assembling operation in the completion of electric motor. During the design of the existing tools the requirements for a functional part of the tool (lifespan, inability to damage the engine installation were fully considered, demands for ergonomic grip area, however, were not taken into account. Long-term use of incorrectly designed tool causes carpal tunnel syndrome, hand-arm vibration syndrome, diminished sensitivity or tingling in the fingers of workers. These difficulties can be reduced or entirely eliminated due to proper design of the grip of hand tool. Most authors focus on adjusting the grip for optimum ergonomics at individual types of grips (cylindrical, palmar, lateral, etc.. However, as already mentioned, there are tools for specific operations when the working area is limited by space or a specific type of load on the grip is needed. In some cases, it is often necessary to change the type of grip or combine different types of grips. This paper describes the design of an optimal grip of hand tool used for specific operation when assembling motors. Design of prototype mold and production of functional prototypes for ergonomics assessment directly in the workplace were realized. New design of handle should reduce the risk primarily of developing carpal tunnel in long-term use.

  7. Analysis of spontaneous and bleomycin-induced chromosome damage in peripheral lymphocytes of long-haul aircrew members from Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Bolzan, Alejandro D. [Laboratorio de Citogenetica y Mutagenesis, Instituto Multidisciplinario de Biologia Celular (IMBICE), C.C. 403, 1900 La Plata (Argentina); Miembro de la Carrera del Investigador Cientifico del CONICET (Argentina)], E-mail: abolzan@imbice.org.ar; Bianchi, Martha S. [Laboratorio de Citogenetica y Mutagenesis, Instituto Multidisciplinario de Biologia Celular (IMBICE), C.C. 403, 1900 La Plata (Argentina); Miembro de la Carrera del Investigador Cientifico del CONICET (Argentina); Gimenez, Esteban M.; Flaque, Maria C. Diaz [Laboratorio de Citogenetica y Mutagenesis, Instituto Multidisciplinario de Biologia Celular (IMBICE), C.C. 403, 1900 La Plata (Argentina); Ciancio, Vicente R. [Universidad Nacional de La Plata, Facultad de Ciencias Medicas, 120 y 60, 1900 La Plata (Argentina)

    2008-03-01

    Spontaneous and bleomycin (BLM)-induced chromosomal aberrations in G0 and G2 stages of the cell cycle have been analyzed in peripheral lymphocytes of 21 long-haul aircrew members from Argentina in order to assess BLM-induced clastogenesis as a first approach to determine the DNA repair capacity and thereby the susceptibility to environmental cancers in aircrew. The possibility that occupational exposure of flight personnel to cosmic radiation can induce an adaptive response in their peripheral lymphocytes that can be detected by a subsequent in vitro treatment with BLM was also investigated. For comparison, aberrations were also scored in the lymphocytes of 15 healthy volunteers matched by age, health, sex, drinking and smoking habits to the flight personnel group. Aircrew exhibited a higher frequency of spontaneous dicentrics and ring chromosomes than the control population (p < 0.05). BLM sensitivity test showed that aircrew and controls are equally sensitive to BLM G2 clastogenic effects, since both groups exhibited a similar frequency of chromatid breaks per cell (p > 0.05). However, the aircrew sampled population was almost two times more sensitive to BLM G0 clastogenic effects than controls (p < 0.05). Therefore, our data suggest that chronic exposure of aircrew to cosmic radiation increases the in vitro chromosomal sensitivity of their peripheral lymphocytes to BLM (at least in the G0 stage of the cell cycle), and that occupational exposure of flight personnel to cosmic radiation does not induce an adaptive response to this radiomimetic compound. Our results justify further studies aimed at determine if those aircrew members hypersensitive to BLM are more prone to develop environmental cancer than BLM-insensitive individuals.

  8. Grip Analysis of Road Surface and Tire Footprint Using FEM

    Science.gov (United States)

    Sabri, M.; Abda, S.

    2018-02-01

    Road grip involve a touch between road pavement and the tire tread pattern. The load bearing surface, which depends on pavement roughness and local pressures in the contact patch. This research conducted to develop a Finite element model for simulating the experimentally testing of asphalt in Jl. AH Nasution Medan, North Sumatera Indonesia base on the value of grip coefficient from various tire loads and the various speed of the vehicle during contact to the road. A tire model and road pavement are developed for the analyses the geometry of tire footprint. The results showed that the greater the mass of car will increase grip coefficient. The coefficient of grip on the road surface contact trough the tire footprint strongly influence the kinetic coefficient of friction at certain speeds. Experimentally show that Concrete road grip coefficient of more than 34% compared to the asphalt road at the same IRI parameters (6-8). Kinetic friction coefficient more than 0.33 was obtained in a asphalt path at a speed of 30-40 Km/hour.

  9. Computational model of precision grip in Parkinson’s disease: A Utility based approach

    Directory of Open Access Journals (Sweden)

    Ankur eGupta

    2013-12-01

    Full Text Available We propose a computational model of Precision Grip (PG performance in normal subjects and Parkinson’s Disease (PD patients. Prior studies on grip force generation in PD patients show an increase in grip force during ON medication and an increase in the variability of the grip force during OFF medication (Fellows et al 1998; Ingvarsson et al 1997. Changes in grip force generation in dopamine-deficient PD conditions strongly suggest contribution of the Basal Ganglia, a deep brain system having a crucial role in translating dopamine signals to decision making. The present approach is to treat the problem of modeling grip force generation as a problem of action selection, which is one of the key functions of the Basal Ganglia. The model consists of two components: 1 the sensory-motor loop component, and 2 the Basal Ganglia component. The sensory-motor loop component converts a reference position and a reference grip force, into lift force and grip force profiles, respectively. These two forces cooperate in grip-lifting a load. The sensory-motor loop component also includes a plant model that represents the interaction between two fingers involved in PG, and the object to be lifted. The Basal Ganglia component is modeled using Reinforcement Learning with the significant difference that the action selection is performed using utility distribution instead of using purely Value-based distribution, thereby incorporating risk-based decision making. The proposed model is able to account for the precision grip results from normal and PD patients accurately (Fellows et. al. 1998; Ingvarsson et. al. 1997. To our knowledge the model is the first model of precision grip in PD conditions.

  10. Grip for sawing round timber

    Energy Technology Data Exchange (ETDEWEB)

    1982-07-01

    This paper describes a device development at Gedling Colliery, Nottinghamshire Area, United Kingdom. It is a gripping attachment, designed to overcome the safety hazards involved in cross cutting timbers with a circular saw.

  11. Tensile testing grips are easily assembled under liquid nitrogen

    Science.gov (United States)

    Skalka, R. J.; Vandergrift, E. F.

    1967-01-01

    Split-screw grips for tensile testing provide uniform loading on the specimen shoulders. Holes in the heads enable the screws and specimen to be threaded as an assembly into a grip body, closely controlled guides and seats afford positive seating, and precision machining of mating surfaces minimizes misalignment effects.

  12. Algorithm Design for Grip-Pattern Verification in Smart Gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  13. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available switchLanguage; BLAST Search Image Search Home About Archive Update History Data List Contact us GRI...PDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gri...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ...

  14. The effects of grip width on sticking region in bench press.

    Science.gov (United States)

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  15. Discrimination of handlebar grip samples by fourier transform infrared microspectroscopy analysis and statistics

    Directory of Open Access Journals (Sweden)

    Zeyu Lin

    2017-01-01

    Full Text Available In this paper, the authors presented a study on the discrimination of handlebar grip samples, to provide effective forensic science service for hit and run traffic cases. 50 bicycle handlebar grip samples, 49 electric bike handlebar grip samples, and 96 motorcycle handlebar grip samples have been randomly collected by the local police in Beijing (China. Fourier transform infrared microspectroscopy (FTIR was utilized as analytical technology. Then, target absorption selection, data pretreatment, and discrimination of linked samples and unlinked samples were chosen as three steps to improve the discrimination of FTIR spectrums collected from different handlebar grip samples. Principal component analysis and receiver operating characteristic curve were utilized to evaluate different data selection methods and different data pretreatment methods, respectively. It is possible to explore the evidential value of handlebar grip residue evidence through instrumental analysis and statistical treatments. It will provide a universal discrimination method for other forensic science samples as well.

  16. Differences in grip force control between young and late middle-aged adults.

    Science.gov (United States)

    Zheng, Lianrong; Li, Kunyang; Wang, Qian; Chen, Wenhui; Song, Rong; Liu, Guanzheng

    2017-09-01

    Grip force control is a crucial function for human to guarantee the quality of life. To examine the effects of age on grip force control, 10 young adults and 11 late middle-aged adults participated in visually guided tracking tasks using different target force levels (25, 50, and 75% of the subject's maximal grip force). Multiple measures were used to evaluate the tracking performance during force rising phase and force maintenance phase. The measurements include the rise time, fuzzy entropy, mean force percentage, coefficient of variation, and target deviation ratio. The results show that the maximal grip force was significantly lower in the late middle-aged adults than in the young adults. The time of rising phase was systematically longer among late middle-aged adults. The fuzzy entropy is a useful indicator for quantitating the force variability of the grip force signal at higher force levels. These results suggest that the late middle-aged adults applied a compensatory strategy that allow allows for sufficient time to reach the required grip force and reduce the impact of the early and subtle degenerative changes in hand motor function.

  17. Wearable flex sensor system for multiple badminton player grip identification

    Science.gov (United States)

    Jacob, Alvin; Zakaria, Wan Nurshazwani Wan; Tomari, Mohd Razali Bin Md; Sek, Tee Kian; Suberi, Anis Azwani Muhd

    2017-09-01

    This paper focuses on the development of a wearable sensor system to identify the different types of badminton grip that is used by a player during training. Badminton movements and strokes are fast and dynamic, where most of the involved movement are difficult to identify with the naked eye. Also, the usage of high processing optometric motion capture system is expensive and causes computational burden. Therefore, this paper suggests the development of a sensorized glove using flex sensor to measure a badminton player's finger flexion angle. The proposed Hand Monitoring Module (HMM) is connected to a personal computer through Bluetooth to enable wireless data transmission. The usability and feasibility of the HMM to identify different grip types were examined through a series of experiments, where the system exhibited 70% detection ability for the five different grip type. The outcome plays a major role in training players to use the proper grips for a badminton stroke to achieve a more powerful and accurate stroke execution.

  18. Grip Force Adjustments Reflect Prediction of Dynamic Consequences in Varying Gravitoinertial Fields

    Directory of Open Access Journals (Sweden)

    Olivier White

    2018-02-01

    Full Text Available Humans have a remarkable ability to adjust the way they manipulate tools through a genuine regulation of grip force according to the task. However, rapid changes in the dynamical context may challenge this skill, as shown in many experimental approaches. Most experiments adopt perturbation paradigms that affect only one sensory modality. We hypothesize that very fast adaptation can occur if coherent information from multiple sensory modalities is provided to the central nervous system. Here, we test whether participants can switch between different and never experienced dynamical environments induced by centrifugation of the body. Seven participants lifted an object four times in a row successively in 1, 1.5, 2, 2.5, 2, 1.5, and 1 g. We continuously measured grip force, load force and the gravitoinertial acceleration that was aligned with body axis (perceived gravity. Participants adopted stereotyped grasping movements immediately upon entry in a new environment and needed only one trial to adapt grip forces to a stable performance in each new gravity environment. This result was underlined by good correlations between grip and load forces in the first trial. Participants predictively applied larger grip forces when they expected increasing gravity steps. They also decreased grip force when they expected decreasing gravity steps, but not as much as they could, indicating imperfect anticipation in that condition. The participants' performance could rather be explained by a combination of successful scaling of grip force according to gravity changes and a separate safety factor. The data suggest that in highly unfamiliar dynamic environments, grip force regulation is characterized by a combination of a successful anticipation of the experienced environmental condition, a safety factor reflecting strategic response to uncertainties about the environment and rapid feedback mechanisms to optimize performance under constant conditions.

  19. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  20. Effect of cervical vs. thoracic spinal manipulation on peripheral neural features and grip strength in subjects with chronic mechanical neck pain: a randomized controlled trial.

    Science.gov (United States)

    Bautista-Aguirre, Francisco; Oliva-Pascual-Vaca, Ángel; Heredia-Rizo, Alberto M; Boscá-Gandía, Juan J; Ricard, François; Rodriguez-Blanco, Cleofás

    2017-06-01

    Cervical and thoracic spinal manipulative therapy has shown positive impact for relief of pain and improve function in non-specific mechanical neck pain. Several attempts have been made to compare their effectiveness although previous studies lacked a control group, assessed acute neck pain or combined thrust and non-thrust techniques. To compare the immediate effects of cervical and thoracic spinal thrust manipulations on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. Randomized, single-blinded, controlled clinical trial. Private physiotherapy clinical consultancy. Eighty-eight subjects (32.09±6.05 years; 72.7% females) suffering neck pain (grades I or II) of at least 12 weeks of duration. Participants were distributed into three groups: 1) cervical group (N.=28); 2) thoracic group (N.=30); and 3) control group (N.=30). One treatment session consisting of applying a high-velocity low-amplitude spinal thrust technique over the lower cervical spine (C7) or the upper thoracic spine (T3) was performed, while the control group received a sham-manual contact. Measurements were taken at baseline and after intervention of the pressure pain threshold over the median, ulnar and radial nerves. Secondary measures included assessing free-pain grip strength with a hydraulic dynamometer. No statistically significant differences were observed when comparing between-groups in any of the outcome measures (P>0.05). Those who received thrust techniques, regardless of the manipulated area, reported an immediate increase in mechanosensitivity over the radial (both sides) and left ulnar nerve trunks (Ppain perception over the radial nerve also improved (P≤0.025). Low-cervical and upper-thoracic thrust manipulation is no more effective than placebo to induce immediate changes on mechanosensitivity of upper limb nerve trunks and grip strength in patients with chronic non-specific mechanical neck pain. A single

  1. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    Science.gov (United States)

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  2. Grip strength as a frailty diagnostic component in geriatric inpatients

    Directory of Open Access Journals (Sweden)

    Dudzińska-Griszek J

    2017-07-01

    Full Text Available Joanna Dudzińska-Griszek, Karolina Szuster, Jan Szewieczek Department of Geriatrics, School of Health Sciences in Katowice, Medical University of Silesia, Katowice, Poland Background: Frailty has emerged as a key medical syndrome predictive of comorbidity, disability, institutionalization and death. As a component of the five frailty phenotype diagnostic criteria, patient grip strength deserves attention as a simple and objective measure of the frailty syndrome. The aim of this study was to assess conditions that influence grip strength in geriatric inpatients.Patients and methods: The study group consisted of 80 patients aged 78.6±7.0 years ( X ± SD, with 68.8% women, admitted to the Department of Geriatrics. A comprehensive geriatric assessment was complemented with assessment for the frailty phenotype as described by Fried et al for all patients in the study group. Functional assessment included Barthel Index of Activities of Daily Living (Barthel Index, Instrumental Activities of Daily Living Scale and Mini-Mental State Examination.Results: Three or more frailty criteria were positive in 32 patients (40%, while 56 subjects (70% fulfilled the frailty criterion of weakness (grip strength test. Multivariate linear regression analysis revealed that two independent measures showed positive association with grip strength – Mini-Mental State Examination score (β=0.239; P=0.001 and statin use (β=0.213; P=0.002 – and four independent measures were negatively associated with grip strength – female sex (β=–0.671; P<0.001, C-reactive protein (β=–0.253; P<0.001, prior myocardial infarction (β=–0.190; P=0.006 and use of an antidepressant (β=–0.163; P=0.018. Low physical activity was identified as the only independent qualitative frailty component associated with 2-year mortality in multivariate logistic regression analysis after adjustment for age and sex (odds ratio =6.000; 95% CI =1.357–26.536; P=0.018.Conclusion: Cognitive

  3. Handling device with grips operated by a servo-motor

    International Nuclear Information System (INIS)

    Sgarbi, F.; Detriche, J.M.

    1990-01-01

    On grip jaws are set up a detection circuit which allows the rocking of the control system from a control system in position to a control system in clamping strain when an object is held, and then which allows to use them by turns in order to keep only their advantages. A larger light touch handling is obtained. The application of this grip is recommended to catch brittle objects (for handicapped persons by example) [fr

  4. Grip Strength and Its Relationship to Police Recruit Task Performance and Injury Risk: A Retrospective Cohort Study.

    Science.gov (United States)

    Orr, Robin; Pope, Rodney; Stierli, Michael; Hinton, Benjamin

    2017-08-21

    Suitable grip strength is a police occupational requirement. The aim of this study was to investigate the association between grip strength, task performance and injury risk in a police population. Retrospective data of police recruits (n = 169) who had undergone basic recruit training were provided, including handgrip strength results, occupational task performance measures (consisting of police task simulations [SIM], tactical options [TACOPS] and marksmanship assessments) and injury records. Left hand grip strength (41.91 ± 8.29 kg) measures showed a stronger correlation than right hand grip strength (42.15 ± 8.53 kg) with all outcome measures. Recruits whose grip strength scores were lower were significantly more susceptible to failing the TACOPS occupational task assessment than those with greater grip strength scores, with significant ( p ≤ 0.003) weak to moderate, positive correlations found between grip strength and TACOPS performance. A significant ( p performance, with those performing better in marksmanship having higher grip strength. Left hand grip strength was significantly associated with injury risk ( r = -0.181, p = 0.018) but right hand grip strength was not. A positive association exists between handgrip strength and police recruit task performance (notably TACOPS and marksmanship) with recruits who scored poorly on grip strength being at greatest risk of occupational assessment task failure.

  5. Inertial torque during reaching directly impacts grip-force adaptation to weightless objects.

    Science.gov (United States)

    Giard, T; Crevecoeur, F; McIntyre, J; Thonnard, J-L; Lefèvre, P

    2015-11-01

    A hallmark of movement control expressed by healthy humans is the ability to gradually improve motor performance through learning. In the context of object manipulation, previous work has shown that the presence of a torque load has a direct impact on grip-force control, characterized by a significantly slower grip-force adjustment across lifting movements. The origin of this slower adaptation rate remains unclear. On the one hand, information about tangential constraints during stationary holding may be difficult to extract in the presence of a torque. On the other hand, inertial torque experienced during movement may also potentially disrupt the grip-force adjustments, as the dynamical constraints clearly differ from the situation when no torque load is present. To address the influence of inertial torque loads, we instructed healthy adults to perform visually guided reaching movements in weightlessness while holding an unbalanced object relative to the grip axis. Weightlessness offered the possibility to remove gravitational constraints and isolate the effect of movement-related feedback on grip force adjustments. Grip-force adaptation rates were compared with a control group who manipulated a balanced object without any torque load and also in weightlessness. Our results clearly show that grip-force adaptation in the presence of a torque load is significantly slower, which suggests that the presence of torque loads experienced during movement may alter our internal estimates of how much force is required to hold an unbalanced object stable. This observation may explain why grasping objects around the expected location of the center of mass is such an important component of planning and control of manipulation tasks.

  6. Longitudinal assessment of grip strength using bulb dynamometer in Duchenne Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Tatiana M. Pizzato

    2014-07-01

    Full Text Available BACKGROUND: Grip strength is used to infer functional status in several pathological conditions, and the hand dynamometer has been used to estimate performance in other areas. However, this relationship is controversial in neuromuscular diseases and studies with the bulb dynamometer comparing healthy children and children with Duchenne Muscular Dystrophy (DMD are limited. OBJECTIVE: The evolution of grip strength and the magnitude of weakness were examined in boys with DMD compared to healthy boys. The functional data of the DMD boys were correlated with grip strength. METHOD: Grip strength was recorded in 18 ambulant boys with DMD (Duchenne Group, DG aged 4 to 13 years (mean 7.4±2.1 and 150 healthy volunteers (Control Group, CG age-matched using a bulb dynamometer (North Coast- NC70154. The follow-up of the DG was 6 to 33 months (3-12 sessions, and functional performance was verified using the Vignos scale. RESULTS: There was no difference between grip strength obtained by the dominant and non-dominant side for both groups. Grip strength increased in the CG with chronological age while the DG remained stable or decreased. The comparison between groups showed significant difference in grip strength, with CG values higher than DG values (confidence interval of 95%. In summary, there was an increment in the differences between the groups with increasing age. Participants with 24 months or more of follow-up showed a progression of weakness as well as maintained Vignos scores. CONCLUSIONS: The amplitude of weakness increased with age in the DG. The bulb dynamometer detected the progression of muscular weakness. Functional performance remained virtually unchanged in spite of the increase in weakness.

  7. Contribution of the Cerebellum in Cue-Dependent Force Changes During an Isometric Precision Grip Task.

    Science.gov (United States)

    Kutz, Dieter F; Schmid, Barbara C; Meindl, Tobias; Timmann, Dagmar; Kolb, Florian P

    2016-08-01

    The "raspberry task" represents a precision grip task that requires continuous adjustment of grip forces and pull forces. During this task, subjects use a specialised grip rod and have to increase the pull force linearly while the rod is locked. The positions of the fingers are unrestrained and freely selectable. From the finger positions and the geometry of the grip rod, a physical lever was derived which is a comprehensive measurement of the subject's grip behaviour. In this study, the involvement of the cerebellum in establishing cued force changes (CFC) was examined. The auditory stimulus was associated with a motor behaviour that has to be readjusted during an ongoing movement that already started. Moreover, cerebellar involvement on grip behaviour was examined. The results show that patients presenting with degenerating cerebellar disease (CBL) were able to elicit CFC and were additionally able to optimise grip behaviour by minimising the lever. Comparison of the results of CBL with a control group of healthy subjects showed, however, that the CFC incidence was significantly lower and the reduction of the lever was less in CBL. Hence, the cerebellum is involved not only in the classical conditioning of reflexes but also in the association of sensory stimuli with complex changes in motor behaviour. Furthermore, the cerebellum is involved in the optimisation of grip behaviour during ongoing movements. Recent studies lead to the assumption that the cerebello-reticulo-spinal pathway might be important for the reduced optimisation of grip behaviour in CBL.

  8. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    Science.gov (United States)

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  9. Grip and Pinch Strength Norms for Michigan Workers

    Directory of Open Access Journals (Sweden)

    Joel M. Phillips M.S., OTRL

    2013-06-01

    Full Text Available The purpose of this study was to create a norm reference of current grip and pinch strength norms for working-age Michigan adults. This normative study included a convenience sample of 179 volunteers who were employees at car plants in South East Michigan or hospital sites in West Michigan. Participants’ ages ranged from between 20 and 62 years of age with a mean age of 49.15 years. There were 78 females (44% and 101 males (56%. Subjects were classified by gender and in the age categories of ages 20 to 49 years and ages 50-62 years. Grip and pinch strength norms were collected following the American Society of Hand Therapy protocol. The norms from these working adults were calculated with descriptive statistics for males and females in two age classifications: ages 20 to 49 and ages 50 to 62 years. Standard Errors (SE are better than the 1985 norms for both males and females ages 20 to 49 years. SEs are higher than the ages 20 to 49 years’ norms for the ages 50 to 62 years age categories in both males and females. These norms offer a point of comparison for clinicians to use for clients in Michigan who are ages 20 to 62 years and who have a goal to improve their grip strength. Clients’ grip and pinch strength could be compared to their age level or gender norms using the comparison for one standard deviation above, below, or at the means.

  10. Hand Grip Strength: age and gender stratified normative data in a population-based study

    Directory of Open Access Journals (Sweden)

    Taylor Anne W

    2011-04-01

    Full Text Available Abstract Background The North West Adelaide Health Study is a representative longitudinal cohort study of people originally aged 18 years and over. The aim of this study was to describe normative data for hand grip strength in a community-based Australian population. Secondary aims were to investigate the relationship between body mass index (BMI and hand grip strength, and to compare Australian data with international hand grip strength norms. Methods The sample was randomly selected and recruited by telephone interview. Overall, 3 206 (81% of those recruited participants returned to the clinic during the second stage (2004-2006 which specifically focused on the collection of information relating to musculoskeletal conditions. Results Following the exclusion of 435 participants who had hand pain and/or arthritis, 1366 men and 1312 women participants provided hand grip strength measurement. The study population was relatively young, with 41.5% under 40 years; and their mean BMI was 28.1 kg/m2 (SD 5.5. Higher hand grip strength was weakly related to higher BMI in adults under the age of 30 and over the age of 70, but inversely related to higher BMI between these ages. Australian norms from this sample had amongst the lowest of the hand grip strength of the internationally published norms, except those from underweight populations. Conclusions This population demonstrated higher BMI and lower grip strength in younger participants than much of the international published, population data. A complete exploration of the relationship between BMI and hand grip strength was not fully explored as there were very few participants with BMI in the underweight range. The age and gender grip strength values are lower in younger adults than those reported in international literature.

  11. Treadmill exercise induced functional recovery after peripheral nerve repair is associated with increased levels of neurotrophic factors.

    Directory of Open Access Journals (Sweden)

    Jae-Sung Park

    Full Text Available Benefits of exercise on nerve regeneration and functional recovery have been reported in both central and peripheral nervous system disease models. However, underlying molecular mechanisms of enhanced regeneration and improved functional outcomes are less understood. We used a peripheral nerve regeneration model that has a good correlation between functional outcomes and number of motor axons that regenerate to evaluate the impact of treadmill exercise. In this model, the median nerve was transected and repaired while the ulnar nerve was transected and prevented from regeneration. Daily treadmill exercise resulted in faster recovery of the forelimb grip function as evaluated by grip power and inverted holding test. Daily exercise also resulted in better regeneration as evaluated by recovery of compound motor action potentials, higher number of axons in the median nerve and larger myofiber size in target muscles. Furthermore, these observations correlated with higher levels of neurotrophic factors, glial derived neurotrophic factor (GDNF, brain derived neurotrophic factor (BDNF and insulin-like growth factor-1 (IGF-1, in serum, nerve and muscle suggesting that increase in muscle derived neurotrophic factors may be responsible for improved regeneration.

  12. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  13. Improvements in or relating to gripping means for handling nuclear reactor fuel assemblies

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Vjugov, O.N.; Fadeev, A.I.; Shkhian, T.G.

    1980-01-01

    A gripping means for handling fuel assemblies, the heads of which are internally recessed to receive gripping jaws, forms part of a reactor refuelling machine and is telescopically accommodated within a manipulator tube of the machine. A through hole is provided to allow cooling medium to be passed through the fuel assemblies to remove afterheat when the gripping means is used to transfer assemblies from a reactor core to spent fuel storage sockets. (author)

  14. Hold, grasp, clutch or grab: consumer grip choices during food container opening.

    Science.gov (United States)

    Rowson, J; Yoxall, A

    2011-07-01

    Society is ageing and sadly that ageing leads to a host of issues, not least a society in which the majority are likely to have some loss of strength and dexterity. This can lead to complications in undertaking everyday tasks such as using transport, bathing or even handling and opening food. Packaging has to provide a multitude of services; to protect and preserve the product, to provide information to the consumer and not least to allow access to the contents. This access to packaging--or 'openability'--has become a significant issue for designers and manufacturers with the change in demographics as described above. Understanding the choices consumers make in how they manipulate packaging can help designers produce packaging that is more able to meet the requirements of modern society. Studies previously undertaken by the authors showed that consumers did use different grips when opening packaging and that certain grips were theoretically more comfortable and stronger than others. This paper outlines a further study whereby consumers were asked to apply the most common grips to a specially designed torque measuring device. Details were taken about the consumers: age, gender, occupation, hand size, plus their preferred grip choice for packaging of this type. The study showed that typically women chose a grip that maximised their opportunity of opening the closure and that this grip choice was more limited than that available for men. This has implications for inclusive design of many everyday products. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  15. GRIP FLIGHT TRACKS AND ANIMATIONS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Flight Tracks and Animations dataset includes both KML files and animation files. The KML files use Google Earth to show the flight tracks on a map. The...

  16. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    Science.gov (United States)

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  17. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis.

    Science.gov (United States)

    Schaefer, Sydney Y; DeJong, Stacey L; Cherry, Kendra M; Lang, Catherine E

    2012-04-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in poststroke hemiparesis. Sixteen adults with poststroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared with the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment.

  18. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  19. GRIP BARBADOS/CAPE VERDE RADIOSONDE V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Barbados/Cape Verde radiosonde data set consists of generally two soundings per day (06Z and 12Z) launched from Barbados, and one sounding per day (12Z)...

  20. GRIP HURRICANE IMAGING RADIOMETER (HIRAD) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Hurricane Imaging Radiometer (HIRAD) V1 dataset contains measurements of brightness temperature taken at 4, 5, 6 and 6.6 GHz, as well as MERRA 2 m wind...

  1. An electromyographic study of the effect of hand grip sizes on forearm muscle activity and golf performance.

    Science.gov (United States)

    Sorbie, Graeme G; Hunter, Henry H; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike Chris

    2016-01-01

    The study describes the differences in surface electromyography (EMG) activity of two forearm muscles in the lead and trail arm at specific phases of the golf swing using a 7-iron with three different grip sizes among amateur and professional golfers. Fifteen right-handed male golfers performed five golf swings using golf clubs with three different grip sizes. Surface EMG was used to measure muscle activity of the extensor carpi radialis brevis (ECRB) and flexor digitorum superficialis (FDS) on both forearms. There were no significant differences in forearm muscle activity when using the three golf grips within the group of 15 golfers (p > 0.05). When using the undersize grip, club head speed significantly increased (p = 0.044). During the backswing and downswing phases, amateurs produced significantly greater forearm muscle activity with all three grip sizes (p < 0.05). In conclusion, forearm muscle activity is not affected by grip sizes. However, club head speed increases when using undersize grips.

  2. Reliability of the Bulb Dynamometer for Assessing Grip Strength

    Directory of Open Access Journals (Sweden)

    Colleen Maher

    2018-04-01

    Full Text Available Background: Hand function is an overall indicator of health and is often measured using grip strength. Handheld dynamometry is the most common method of measuring grip strength. The purpose of this study was to determine the inter-rater and test-retest reliability, the reliability of one trial versus three trials, and the preliminary norms for a young adult population using the Baseline® Pneumatic Squeeze Bulb Dynamometer (30 psi. Methods: This study used a one-group methodological design. One hundred and three healthy adults (30 males and 73 females were recruited. Six measurements were collected for each hand per participant. The data was analyzed using Intraclass Correlation Coefficients (ICC two-way effects model (2,2 and paired-samples t-tests. Results: The ICC for inter-rater reliability ranged from 0.955 to 0.977. Conclusion: The results of this study suggest that the bulb dynamometer is a reliable tool to measure grip strength and should be further explored for reliable and valid use in diverse populations and as an alternative to the Jamar dynamometer.

  3. The end-state comfort effect in bimanual grip selection.

    Science.gov (United States)

    Fischman, Mark G; Stodden, David F; Lehman, Davana M

    2003-03-01

    During a unimanual grip selection task in which people pick up a lightweight dowel and place one end against targets at variable heights, the choice of hand grip (overhand vs. underhand) typically depends on the perception of how comfortable the arm will be at the end of the movement: an end-state comfort effect. The two experiments reported here extend this work to bimanual tasks. In each experiment, 26 right-handed participants used their left and right hands to simultaneously pick up two wooden dowels and place either the right or left end against a series of 14 targets ranging from 14 to 210 cm above the floor. These tasks were performed in systematic ascending and descending orders in Experiment 1 and in random order in Expiment 2. Results were generally consistent with predictions of end-state comfort in that, for the extreme highest and lowest targets, participants tended to select opposite grips with each hand. Taken together, our findings are consistent with the concept of constraint hierarchies within a posture-based motion-planning model.

  4. Probabilistic information on object weight shapes force dynamics in a grip-lift task.

    Science.gov (United States)

    Trampenau, Leif; Kuhtz-Buschbeck, Johann P; van Eimeren, Thilo

    2015-06-01

    Advance information, such as object weight, size and texture, modifies predictive scaling of grip forces in a grip-lift task. Here, we examined the influence of probabilistic advance information about object weight. Fifteen healthy volunteers repeatedly grasped and lifted an object equipped with a force transducer between their thumb and index finger. Three clearly distinguishable object weights were used. Prior to each lift, the probabilities for the three object weights were given by a visual cue. We examined the effect of probabilistic pre-cues on grip and lift force dynamics. We expected predictive scaling of grip force parameters to follow predicted values calculated according to probabilistic contingencies of the cues. We observed that probabilistic cues systematically influenced peak grip and load force rates, as an index of predictive motor scaling. However, the effects of probabilistic cues on force rates were nonlinear, and anticipatory adaptations of the motor output generally seemed to overestimate high probabilities and underestimate low probabilities. These findings support the suggestion that anticipatory adaptations and force scaling of the motor system can integrate probabilistic information. However, probabilistic information seems to influence motor programs in a nonlinear fashion.

  5. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players.

    Science.gov (United States)

    Wieczorek, Marta; Wiliński, Wojciech; Struzik, Artur; Rokita, Andrzej

    2015-11-22

    Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 - 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  6. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  7. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS... Actuator Showing Grip Dimension EC03OC91.072 ...

  8. GRIP LIDAR ATMOSPHERIC SENSING EXPERIMENT (LASE) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lidar Atmospheric Sensing Experiment (LASE) dataset was collected by NASA's Lidar Atmospheric Sensing Experiment (LASE) system, which is an airborne...

  9. Studying hand grip strength development among students who have taken tennis and massage courses

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2017-01-01

    Full Text Available In this study, the finger and hand force developments of the students who have taken selective/applied Tennis and Massage courses at the University have been examined. From the students of the Department of Physical Education and Sport, 19 healthy females and 73 healthy males (age = 21.25 ± 1.55 years (average ± SD who have taken selective Tennis courses;51 healthy males (age = 22.00 ± 1.04 years (average ± SD who have taken Massage courses; and as the control group,16 healthy womenand50 healthy males(age = 21.72 ± 1.47 years (average ± SD have been participated to the study. The age, length, body weight, grip strength of both hands as well as the finger grip strength of the subjects have been recorded. The course schedule has been set as once a week four hours practice for both tennis and massage. Two weeks of the education and training program that takes twelve weeks in total were assigned for theoretical classes. The remaining period of ten weeks was for practice classes and the measurements were performed before and after this ten weeks period. The hand grip strength measurement has been carried out with a Takkei branded hand dynamometer whereas for the measurement of the finger grip strength, a Baseline branded pinch meter has been used. For both the pre-test and final test of the finger grip and hand grip strength measurements, the paired sample t test has been used in terms of in-group comparisons, whereas for the inter-group comparisons, one-way ANOVA has been used. For the significant F values, post hoc Tukey test has been used. The right hand and the left hand grip values of both test groups as well as the values of the control group have been significantly increased between the pre-test and final test. Particularly, preferring the exercises that improve the hand and finger grip strengths would enable a better racket handle grip as well as an improved shot efficiency for tennis. This would also enable masseurs/masseuses to apply

  10. Relationship between lung function and grip strength in older hospitalized patients: a pilot study

    Directory of Open Access Journals (Sweden)

    Holmes SJ

    2017-04-01

    Full Text Available Sarah J Holmes,1 Stephen C Allen,2,3 Helen C Roberts4,5 1Medicine and Elderly Care, Hampshire Hospitals NHS Foundation Trust, Winchester, 2Medicine and Geriatrics, The Royal Bournemouth Hospital and Christchurch Hospitals NHS Foundation Trust, Bournemouth, 3Centre of Postgraduate Medical Research and Education, Bournemouth University, Poole, 4Academic Geriatric Medicine, University of Southampton, 5University Hospital Southampton NHS Foundation Trust, Southampton, UK Objective: Older people with reduced respiratory muscle strength may be misclassified as having COPD on the basis of spirometric results. We aimed to evaluate the relationship between lung function and grip strength in older hospitalized patients without known airways disease.Methods: Patients in acute medical wards were recruited who were aged ≥70 years; no history, symptoms, or signs of respiratory disease; Mini Mental State Examination ≥24; willing and able to consent to participate; and able to perform hand grip and forced spirometry. Data including lung function (forced expiratory volume in 1 second [FEV1], forced vital capacity [FVC], FEV1/FVC, peak expiratory flow rate [PEFR], and slow vital capacity [SVC], grip strength, age, weight, and height were recorded. Data were analyzed using descriptive statistics and linear regression unadjusted and adjusted (for age, height, and weight.Results: A total of 50 patients (20 men were recruited. Stronger grip strength in men was significantly associated with greater FEV1, but this was attenuated by adjustment for age, height, and weight. Significant positive associations were found in women between grip strength and both PEFR and SVC, both of which remained robust to adjustment.Conclusion: The association between grip strength and PEFR and SVC may reflect stronger patients generating higher intrathoracic pressure at the start of spirometry and pushing harder against thoracic cage recoil at end-expiration. Conversely, patients with

  11. Transient receptor potential cation channel, subfamily C, member 5 (TRPC5) is a cold-transducer in the peripheral nervous system.

    Science.gov (United States)

    Zimmermann, Katharina; Lennerz, Jochen K; Hein, Alexander; Link, Andrea S; Kaczmarek, J Stefan; Delling, Markus; Uysal, Serdar; Pfeifer, John D; Riccio, Antonio; Clapham, David E

    2011-11-01

    Detection and adaptation to cold temperature is crucial to survival. Cold sensing in the innocuous range of cold (>10-15 °C) in the mammalian peripheral nervous system is thought to rely primarily on transient receptor potential (TRP) ion channels, most notably the menthol receptor, TRPM8. Here we report that TRP cation channel, subfamily C member 5 (TRPC5), but not TRPC1/TRPC5 heteromeric channels, are highly cold sensitive in the temperature range 37-25 °C. We found that TRPC5 is present in mouse and human sensory neurons of dorsal root ganglia, a substantial number of peripheral nerves including intraepithelial endings, and in the dorsal lamina of the spinal cord that receives sensory input from the skin, consistent with a potential TRPC5 function as an innocuous cold transducer in nociceptive and thermosensory nerve endings. Although deletion of TRPC5 in 129S1/SvImJ mice resulted in no temperature-sensitive behavioral changes, TRPM8 and/or other menthol-sensitive channels appear to underpin a much larger component of noxious cold sensing after TRPC5 deletion and a shift in mechanosensitive C-fiber subtypes. These findings demonstrate that highly cold-sensitive TRPC5 channels are a molecular component for detection and regional adaptation to cold temperatures in the peripheral nervous system that is distinct from noxious cold sensing.

  12. Why pens have rubbery grips

    Science.gov (United States)

    Dzidek, Brygida; Bochereau, Séréna; Johnson, Simon A.; Hayward, Vincent; Adams, Michael J.

    2017-10-01

    The process by which human fingers gives rise to stable contacts with smooth, hard objects is surprisingly slow. Using high-resolution imaging, we found that, when pressed against glass, the actual contact made by finger pad ridges evolved over time following a first-order kinetics relationship. This evolution was the result of a two-stage coalescence process of microscopic junctions made between the keratin of the stratum corneum of the skin and the glass surface. This process was driven by the secretion of moisture from the sweat glands, since increased hydration in stratum corneum causes it to become softer. Saturation was typically reached within 20 s of loading the contact, regardless of the initial moisture state of the finger and of the normal force applied. Hence, the gross contact area, frequently used as a benchmark quantity in grip and perceptual studies, is a poor reflection of the actual contact mechanics that take place between human fingers and smooth, impermeable surfaces. In contrast, the formation of a steady-state contact area is almost instantaneous if the counter surface is soft relative to keratin in a dry state. It is for this reason that elastomers are commonly used to coat grip surfaces.

  13. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  14. Identification of dynapenia in older adults through the use of grip strength t-scores.

    Science.gov (United States)

    Bohannon, Richard W; Magasi, Susan

    2015-01-01

    The aim of this study was to generate reference values and t-scores (1.0-2.5 standard deviations below average) for grip strength for healthy young adults and to examine the utility of t-scores from this group for the identification of dynapenia in older adults. Our investigation was a population-based, general community secondary analysis of cross-sectional grip strength data utilizing the NIH Toolbox Assessment norming sample. Participants consisted of community-dwelling adults, with age ranges of 20-40 years (n = 558) and 60-85 years (n = 390). The main outcome measure was grip strength using a Jamar plus dynamometer. Maximum grip strengths were consistent over the 20-40-year age group [men 108.0 (SD 22.6) pounds, women 65.8 (SD 14.6) pounds]. Comparison of older group grip strengths to those of the younger reference group revealed (depending on age strata) that 46.2-87.1% of older men and 50.0-82.4% of older women could be designated as dynapenic on the basis of t-scores. The use of reference value t-scores from younger adults is a promising method for determining dynapenia in older adults. © 2014 Wiley Periodicals, Inc.

  15. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  16. Grip strength in mice with joint inflammation: A rheumatology function test sensitive to pain and analgesia.

    Science.gov (United States)

    Montilla-García, Ángeles; Tejada, Miguel Á; Perazzoli, Gloria; Entrena, José M; Portillo-Salido, Enrique; Fernández-Segura, Eduardo; Cañizares, Francisco J; Cobos, Enrique J

    2017-10-01

    Grip strength deficit is a measure of pain-induced functional disability in rheumatic disease. We tested whether this parameter and tactile allodynia, the standard pain measure in preclinical studies, show parallels in their response to analgesics and basic mechanisms. Mice with periarticular injections of complete Freund's adjuvant (CFA) in the ankles showed periarticular immune infiltration and synovial membrane alterations, together with pronounced grip strength deficits and tactile allodynia measured with von Frey hairs. However, inflammation-induced tactile allodynia lasted longer than grip strength alterations, and therefore did not drive the functional deficits. Oral administration of the opioid drugs oxycodone (1-8 mg/kg) and tramadol (10-80 mg/kg) induced a better recovery of grip strength than acetaminophen (40-320 mg/kg) or the nonsteroidal antiinflammatory drugs ibuprofen (10-80 mg/kg) or celecoxib (40-160 mg/kg); these results are consistent with their analgesic efficacy in humans. Functional impairment was generally a more sensitive indicator of drug-induced analgesia than tactile allodynia, as drug doses that attenuated grip strength deficits showed little or no effect on von Frey thresholds. Finally, ruthenium red (a nonselective TRP antagonist) or the in vivo ablation of TRPV1-expressing neurons with resiniferatoxin abolished tactile allodynia without altering grip strength deficits, indicating that the neurobiology of tactile allodynia and grip strength deficits differ. In conclusion, grip strength deficits are due to a distinct type of pain that reflects an important aspect of the human pain experience, and therefore merits further exploration in preclinical studies to improve the translation of new analgesics from bench to bedside. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Precision grip responses to unexpected rotational perturbations scale with axis of rotation.

    Science.gov (United States)

    De Gregorio, Michael; Santos, Veronica J

    2013-04-05

    It has been established that rapid, pulse-like increases in precision grip forces ("catch-up responses") are elicited by unexpected translational perturbations and that response latency and strength scale according to the direction of linear slip relative to the hand as well as gravity. To determine if catch-up responses are elicited by unexpected rotational perturbations and are strength-, axis-, and/or direction-dependent, we imposed step torque loads about each of two axes which were defined relative to the subject's hand: the distal-proximal axis away from and towards the subject's palm, and the grip axis which connects the two fingertips. Precision grip responses were dominated initially by passive mechanics and then by active, unimodal catch-up responses. First dorsal interosseous activity, marking the start of the catch-up response, began 71-89 ms after the onset of perturbation. The onset latency, shape, and duration (217-231 ms) of the catch-up response were not affected by the axis, direction, or magnitude of the rotational perturbation, while strength was scaled by axis of rotation and slip conditions. Rotations about the grip axis that tilted the object away from the palm and induced rotational slip elicited stronger catch-up responses than rotations about the distal-proximal axis that twisted the object between the digits. To our knowledge, this study is the first to investigate grip responses to unexpected torque loads and to show characteristic, yet axis-dependent, catch-up responses for conditions other than pure linear slip. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Hand grip endurance test relates to clinical state and prognosis in COPD patients better than 6-minute walk test distance

    Directory of Open Access Journals (Sweden)

    Kovarik M

    2017-12-01

    Full Text Available Miroslav Kovarik,1,2 Vera Joskova,1,2 Anna Patkova,1,2 Vladimir Koblizek,3 Zdenek Zadak,2 Miloslav Hronek1,2 1Department of Biological and Medical Sciences, Faculty of Pharmacy in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic; 2Department of Research and Development, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic; 3Department of Pulmonary Medicine, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic Purpose: Patients with COPD present peripheral muscle dysfunction and atrophy, expressed as muscle strength and endurance reduction. The goal of this study was direct dynamometric assessment of hand grip endurance and strength in relation to the stage of disease, multidimensional predictors of mortality, and 6-minute walk test (6MWT. To the best of our knowledge, there has been no previous study determining these parameters.Patients and methods: In this observational study, 58 consecutive outpatients with stable COPD and 25 volunteers without respiratory problems were compared. All COPD subjects underwent a comprehensive examination to determine COPD severity, prognostic scales, and 6MWT. Body composition, basic spirometric parameters, and hand grip strength and endurance were determined in all study participants.Results: Patients in the COPD group had a 15% decrease in maximum strength (P=0.012 and a 28% decrease in area under the force/time curve (AUC of the endurance test (P<0.001 compared to the control group. Dynamometric parameters were significantly negatively associated with the stage of disease and values of multivariable prediction indexes, and positively associated with the results of 6MWT. In most cases, closer associations were found with AUC than with 6MWT and in the gender-specific groups.Conclusion: Both hand grip strength and endurance are impaired in COPD patients in comparison with the control group. In particular, AUC could be considered as an attractive option not only to

  19. Enter the Gripping Beast

    DEFF Research Database (Denmark)

    Sindbæk, Søren Michael

    2012-01-01

    on innovations. Mostly, however, the time-resolution of archaeological data is too coarse-grained to allow us to grasp this potential to the full. In the period c. AD 790-850 a distinctly new artistic motif, the Gripping Beast, emerged in Scandinavia. A series of narrowly dated contexts provide anchor points......, which allows us to chart this innovation process and to point out some of the locations where this development took place; the reception of the mew motif is traced in grave finds across Scandinavia. This allows us to follow an early medieval innovation through the human-material interactions of an actor-network....

  20. Association between grip strength and hand and knee radiographic osteoarthritis in Korean adults: Data from the Dong-gu study.

    Directory of Open Access Journals (Sweden)

    Lihui Wen

    Full Text Available We assessed whether grip strength was related to various types of radiographic damage in Korean adults with osteoarthritis (OA.Data from 2,251 subjects enrolled in the Dong-gu study, who had no hand joint pain, were analyzed to investigate the relationship between grip strength and OA. Hand grip strength was measured using a hand-held dynamometer, and radiographs of the hand and knee were scored according to a semi-quantitative grading system. Multiple linear regressions were used to explore associations between grip strength and radiographic features of OA.Grip strength in men and women was negatively related to hand (both p < 0.001 and knee (men, p < 0.001; women, p = 0.010 OA after adjusting for confounders. Hand (men, p < 0.001; women, p = 0.001 and knee (both p < 0.001 joint space narrowing (JSN showed the strongest associations with low grip strength, regardless of gender. Moreover, the severity of hand osteophytes in women (p = 0.001, and subchondral cysts (men, p < 0.001 was correlated with low grip strength in both genders.Among subjects without hand joint pain, low grip strength was associated significantly with hand and knee radiographic OA, regardless of gender. Among all types of OA radiographic damage, low grip strength showed the strongest association with JSN.

  1. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  2. Dynamical Coordination of Hand Intrinsic Muscles for Precision Grip in Diabetes Mellitus.

    Science.gov (United States)

    Li, Ke; Wei, Na; Cheng, Mei; Hou, Xingguo; Song, Jun

    2018-03-12

    This study investigated the effects of diabetes mellitus (DM) on dynamical coordination of hand intrinsic muscles during precision grip. Precision grip was tested using a custom designed apparatus with stable and unstable loads, during which the surface electromyographic (sEMG) signals of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) were recorded simultaneously. Recurrence quantification analysis (RQA) was applied to quantify the dynamical structure of sEMG signals of the APB and FDI; and cross recurrence quantification analysis (CRQA) was used to assess the intermuscular coupling between the two intrinsic muscles. This study revealed that the DM altered the dynamical structure of muscle activation for the FDI and the dynamical intermuscular coordination between the APB and FDI during precision grip. A reinforced feedforward mechanism that compensates the loss of sensory feedbacks in DM may be responsible for the stronger intermuscular coupling between the APB and FDI muscles. Sensory deficits in DM remarkably decreased the capacity of online motor adjustment based on sensory feedback, rendering a lower adaptability to the uncertainty of environment. This study shed light on inherent dynamical properties underlying the intrinsic muscle activation and intermuscular coordination for precision grip and the effects of DM on hand sensorimotor function.

  3. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    Science.gov (United States)

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Directory of Open Access Journals (Sweden)

    Olivier eWhite

    2015-02-01

    Full Text Available In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force, normal to the finger/object contact, in anticipation of the expected tangential load force, resulting from the combination of the gravitational and the inertial forces. In many contexts, grip force and load force are linearly coupled. A few studies have examined how we adjust the parameters - gain and offset - of this linear relationship. However, the question remains open as to how the brain adjusts grip force regardless of whether load force is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of load force by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust grip force, the brain is sensitive to how load forces are produced at the fingertips. This provides clear evidence that the analysis of the origin of load force is performed centrally, and not only at the periphery.

  5. Ancient death-grip leaf scars reveal ant–fungal parasitism

    Science.gov (United States)

    Hughes, David P.; Wappler, Torsten; Labandeira, Conrad C.

    2011-01-01

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia. PMID:20719770

  6. Ancient death-grip leaf scars reveal ant-fungal parasitism.

    Science.gov (United States)

    Hughes, David P; Wappler, Torsten; Labandeira, Conrad C

    2011-02-23

    Parasites commonly manipulate host behaviour, and among the most dramatic examples are diverse fungi that cause insects to die attached to leaves. This death-grip behaviour functions to place insects in an ideal location for spore dispersal from a dead body following host death. Fossil leaves record many aspects of insect behaviour (feeding, galls, leaf mining) but to date there are no known examples of behavioural manipulation. Here, we document, to our knowledge, the first example of the stereotypical death grip from 48 Ma leaves of Messel, Germany, indicating the antiquity of this behaviour. As well as probably being the first example of behavioural manipulation in the fossil record, these data support a biogeographical parallelism between mid Eocene northern Europe and recent southeast Asia.

  7. Multiple fuel rod gripper

    International Nuclear Information System (INIS)

    Shields, E.P.

    1987-01-01

    An apparatus is described for gripping an array of rods comprising: (a) gripping members grippingly engageable with the rods, each of which has a hollow portion terminating in an open end for receiving the end of one of the rods; (b) a closing means for causing the hollow portion of each of the gripping members to apply substantially the same gripping force onto the end of its respective rod, including (i) a locking plate having a plurality of tapered holes registrable with the array of rods, wherein the exterior of each of the gripping members is tapered and nested within one of the tapered holes, (ii) a withdrawing means having a hydraulic plunger operatively connected to each of the gripping members for applying a substantially identical withdrawing force on each of the gripping members, whereby the hollow portion of each of the gripping members applies substantially the same gripping force on its respective rod, and (c) means for detecting whether each of the gripping members has grippingly engaged its respective rod

  8. Getting a grip on affordances, attention and visual fields

    OpenAIRE

    Linden, Lotje van der; Theeuwes, Jan; Ellis, Rob

    2013-01-01

    van der Linden, L., Theeuwes, J., & Ellis, R. (2012). Getting a grip on affordances, attention, and visual fields. Poster presented at the 2012 William James Graduate School Symposium, Amsterdam, The Netherlands.

  9. GRIP DC-8 NAVIGATION AND HOUSEKEEPING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset contains aircraft navigational data obtained during the GRIP campaign (15 Aug 2010 - 30 Sep 2010). The NASA DC-8 is outfitted with a navigational...

  10. The handyman's brain: a neuroimaging meta-analysis describing the similarities and differences between grip type and pattern in humans.

    Science.gov (United States)

    King, M; Rauch, H G; Stein, D J; Brooks, S J

    2014-11-15

    Handgrip is a ubiquitous human movement that was critical in our evolution. However, the differences in brain activity between grip type (i.e. power or precision) and pattern (i.e. dynamic or static) are not fully understood. In order to address this, we performed Activation Likelihood Estimation (ALE) analysis between grip type and grip pattern using functional magnetic resonance imaging (fMRI) data. ALE provides a probabilistic summary of the BOLD response in hundreds of subjects, which is often beyond the scope of a single fMRI experiment. We collected data from 28 functional magnetic resonance data sets, which included a total of 398 male and female subjects. Using ALE, we analyzed the BOLD response during power, precision, static and dynamic grip in a range of forces and age in right handed healthy individuals without physical impairment, cardiovascular or neurological dysfunction using a variety of grip tools, feedback and experimental training. Power grip generates unique activation in the postcentral gyrus (areas 1 and 3b) and precision grip generates unique activation in the supplementary motor area (SMA, area 6) and precentral gyrus (area 4a). Dynamic handgrip generates unique activation in the precentral gyrus (area 4p) and SMA (area 6) and of particular interest, both dynamic and static grip share activation in the area 2 of the postcentral gyrus, an area implicated in the evolution of handgrip. According to effect size analysis, precision and dynamic grip generates stronger activity than power and static, respectively. Our study demonstrates specific differences between grip type and pattern. However, there was a large degree of overlap in the pre and postcentral gyrus, SMA and areas of the frontal-parietal-cerebellar network, which indicates that other mechanisms are potentially involved in regulating handgrip. Further, our study provides empirically based regions of interest, which can be downloaded here within, that can be used to more effectively

  11. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  12. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    Science.gov (United States)

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m 2 ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  13. Anticipating different grips reduces bimanual end-state comfort: A tradeoff between goal-related and means-related planning processes.

    Directory of Open Access Journals (Sweden)

    Christian Seegelke

    Full Text Available The present study explored the sensitivity towards bimanual end-state comfort in a task that required anticipating different final grips. Participants simultaneously reached and grasped two objects with either a whole-hand grip (WHG or a precision grip (PG, and placed them at two target locations by transporting them either over or under an obstacle. The transport path was varied such that it could be either congruent (i.e., both objects over or under or incongruent (i.e., one object over and the other object under. In the congruent conditions, participants satisfied bimanual end-state comfort (and identical initial grips on the majority of trials. That is, participants adopted a PG for either hand when the objects were transported over the obstacle and a WHG for either hand when the objects were transported under the obstacle. In contrast, in the incongruent conditions, bimanual end-state comfort was significantly reduced, indicating the presence of intermanual inference. The results indicate that goal-related planning constraints (i.e., bimanual end-state comfort do not strictly take precedence over means-related constraints (i.e., identical initial grips if this requires anticipating different final grips. Thus, bimanual end-state comfort per se does not provide a predominant constraint in action selection, by which sensorimotor interference can be reduced. In line with the proposal that bimanual grip planning relies on a flexible constraint hierarchy, a simple formal model that considers bimanual grip posture planning as a tradeoff between goal-related and means-related planning processes can explain our results reasonably well.

  14. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating.

    Science.gov (United States)

    Ramadan, Mohamed Z

    2017-12-04

    Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation) of 30.44 (5.35) years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI), hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C) and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove). The data were analyzed using the Shapiro-Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA) of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C) had a significant influence on grip when compared to medium (25 °C) and high (45 °C) hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  15. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction

    Directory of Open Access Journals (Sweden)

    Zheng Huiru

    2009-01-01

    Full Text Available Abstract Background Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases and non-interacting proteins (negative cases are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. Results GRIP (Gold Reference dataset constructor from Information on Protein complexes is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. Conclusion GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  16. Adaptive grip force is modulated by subthalamic beta activity in Parkinson's disease patients

    Directory of Open Access Journals (Sweden)

    Lukas L. Imbach

    2015-01-01

    Conclusion: The time-locked suppression of beta oscillatory activity in the STN is in line with previous reports of beta ERD prior to voluntary movements. Our results show that the STN is involved in anticipatory grip force control in PD patients. The difference in the phasic beta ERD between the two tasks and the reduction of cortico-subthalamic synchronization suggests that qualitatively different neuronal network states are involved in different grip force control tasks.

  17. The development of a methodology to determine the relationship in grip size and pressure to racket head speed in a tennis forehand stroke

    DEFF Research Database (Denmark)

    Christensen, Jonas; Rasmussen, John; Halkon, Ben

    2016-01-01

    and kinematic contribution of the body segments in the upper trunk translational and angular velocities. Two Babolat Pure Storm GT rackets, with grip sizes 2 and 4 respectively, were used with Tekscan 9811E pressure sensors applied to the handles to examine pressure distribution during the stroke. Upper body...... kinematic data taken from the racket arm and trunk were obtained by means of a Vicon motion capture system. One elite male tennis player was recruited. Fifty topspin forehand strokes per grip at two nominal grip pressures were performed in a laboratory environment with balls being tossed towards the player...... joint and wrist joint in KCAV across grip conditions. Grip pressure for grip size 2 showed the same pattern across gripping conditions. From 50-75% of completion in forward swing, the pressure difference due to grip firmness decreased. This feasibility study managed to quantify the KCAV while performing...

  18. Mind Your Grip: Even Usual Dexterous Manipulation Requires High Level Cognition

    Directory of Open Access Journals (Sweden)

    Erwan Guillery

    2017-11-01

    Full Text Available Simultaneous execution of cognitive and sensorimotor tasks is critical in daily life. Here, we examined whether dexterous manipulation, a highly habitual and seemingly automatic behavior, involves high order cognitive functions. Specifically, we explored the impact of reducing available cognitive resources on the performance of a precision grip-lift task in healthy participants of three age groups (18–30, 30–60 and 60–75 years. Participants performed a motor task in isolation (M, in combination with a low-load cognitive task (M + L, and in combination with a high-load cognitive task (M + H. The motor task consisted in grasping, lifting and holding an apparatus instrumented with force sensors to monitor motor task performance. In the cognitive task, a list of letters was shown briefly before the motor task. After completing the motor task, one letter of the list was shown, and participants reported the following letter of the list. In M + L, letters in the list followed the alphabetical order. In M + H, letters were presented in random order. Performing the high-load task thus required maintaining information in working memory. Temporal and dynamic parameters of grip and lift forces were compared across conditions. During the cognitive tasks, there was a significant alteration of movement initiation and a significant increase of grip force (GF throughout the grip-lift task. There was no interaction with “age”. Our results demonstrate that planning and the on-line control of dexterous manipulation is not an automatic behavior and, instead, that it interacts with high-level cognitive processes such as those involved in working memory.

  19. The Effects of Industrial Protective Gloves and Hand Skin Temperatures on Hand Grip Strength and Discomfort Rating

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-12-01

    Full Text Available Daily working activities and functions require a high contribution of hand and forearm muscles in executing grip force. To study the effects of wearing different gloves on grip strength, under a variety of hand skin temperatures, an assessment of the maximum grip strength was performed with 32 healthy male workers with a mean age (standard deviation of 30.44 (5.35 years wearing five industrial gloves at three hand skin temperatures. Their ages and anthropometric characteristics including body mass index (BMI, hand length, hand width, hand depth, hand palm, and wrist circumference were measured. The hand was exposed to different bath temperatures (5 °C, 25 °C, and 45 °C and hand grip strength was measured using a Jamar hydraulic hand dynamometer with and without wearing the gloves (chemical protection glove, rubber insulating glove, anti-vibration impact glove, cotton yarn knitted glove, and RY-WG002 working glove. The data were analyzed using the Shapiro–Wilk test, Pearson correlation coefficient, Tukey test, and analysis of variance (ANOVA of the within-subject design analysis. The results showed that wearing gloves significantly affected the maximum grip strength. Wearing the RY-WG002 working glove produced a greater reduction on the maximum grip when compared with the bare hand, while low temperatures (5 °C had a significant influence on grip when compared to medium (25 °C and high (45 °C hand skin temperatures. In addition, participants felt more discomfort in both environmental extreme conditions. Furthermore, they reported more discomfort while wearing neoprene, rubber, and RY-WG002 working gloves.

  20. Grip strength is not associated with incident type 2 diabetes mellitus in healthy adults: The CoLaus study.

    Science.gov (United States)

    Marques-Vidal, Pedro; Vollenweider, Peter; Waeber, Gérard; Jornayvaz, François R

    2017-10-01

    We examined the association of grip strength with incident type 2 diabetes mellitus (T2DM) in healthy subjects initially aged 50 to 75years after a follow-up of 5.5years and 10.7years. This was a prospective, population-based study derived from the CoLaus (Cohorte Lausannoise) study including 2318 participants (aged 60.2y; 1354 women) free from T2DM at baseline. Grip strength was assessed using a handheld dynamometer. The effect of grip strength on the incidence of T2DM was analyzed by logistic regression. After a follow-up of 5.5years, 190 (8.2%) T2DM cases were identified. In bivariate analysis, participants who developed T2DM had a higher absolute grip strength (35.3±10.6 versus 33.2±10.7kg, P=0.013). Analysis between grip strength expressed in 5kg increment and incident TD2M showed a negative association when adjusted for age and sex [ORs (95% CI): 0.88 (0.79, 0.98)], or for age, sex and body mass index (BMI) [ORs (95% CI): 0.87 (0.78, 097)]. After a follow-up of 10.7years, 131 supplemental (7.3%) T2DM cases were identified, but there was no association between grip strength and incident T2DM in bivariate and multivariable analysis, potentially due to a lack of statistical power. In non elderly healthy adults, the risk of incident T2DM is overall not associated with grip strength over a maximum follow-up of 10.7years. Future studies are warranted to better assess the association between grip strength and incident T2DM in bigger and even younger cohorts. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Direct observation of salts as micro-inclusions in the Greenland GRIP ice core

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Sakurai, Toshimitsu; Iizuka, Yoshinori

    2009-01-01

    We provide the first direct evidence that a number of water-soluble compounds, in particular calcium sulfate (CaSO4·2H2O) and calcium carbonate (CaCO3), are present as solid, micron-sized inclusions within the Greenland GRIP ice core. The compounds are detected by two independent methods: micro...... distributions of the micro-inclusions. These results suggest that water-soluble aerosols in the GRIP ice core are dependable proxies for past atmospheric conditions. Udgivelsesdato: December...

  2. Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    Science.gov (United States)

    Enders, Leah R; Seo, Na Jin

    2011-05-17

    This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold the cylinder), while normal and shear forces at each phalanx of all five fingers in the direction orthogonal to the gravity were recorded. The cylinder surface was varied for high-friction rubber and low-friction paper coverings. An increase in surface friction by replacing the paper covering with the rubber covering resulted in 4% greater mean phalanx normal force (perpendicular to the cylinder surface) and 22% greater mean phalanx shear force in either the proximal or distal direction of the digits (pfriction with the rubber surface compared to the paper surface was associated with a 20% increase in the angular deviation of the phalanx force from the direction normal to the cylinder surface (p<0.05). This study demonstrates that people significantly changed the magnitude and direction of phalanx forces depending on the surface they gripped. Such change in the grip strategy appears to help increase grip force generation capacity. This finding suggests that a seemingly simple power grip exertion involves sensory feedback-based motor control, and that people's power grip capacity may be reduced in cases of numbness, glove use, or injuries resulting in reduced sensation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Calpain-GRIP Signaling in Nucleus Accumbens Core Mediates the Reconsolidation of Drug Reward Memory.

    Science.gov (United States)

    Liang, Jie; Li, Jia-Li; Han, Ying; Luo, Yi-Xiao; Xue, Yan-Xue; Zhang, Yàn; Zhang, Yán; Zhang, Li-Bo; Chen, Man-Li; Lu, Lin; Shi, Jie

    2017-09-13

    Exposure to drug-paired cues causes drug memories to be in a destabilized state and interfering with memory reconsolidation can inhibit relapse. Calpain, a calcium-dependent neutral cysteine protease, is involved in synaptic plasticity and the formation of long-term fear memory. However, the role of calpain in the reconsolidation of drug reward memory is still unknown. In the present study, using a conditioned place preference (CPP) model, we found that exposure to drug-paired contextual stimuli induced the activation of calpain and decreased the expression of glutamate receptor interacting protein 1 (GRIP1) in the nucleus accumbens (NAc) core, but not shell, of male rats. Infusions of calpain inhibitors in the NAc core immediately after retrieval disrupted the reconsolidation of cocaine/morphine cue memory and blocked retrieval-induced calpain activation and GRIP1 degradation. The suppressive effect of calpain inhibitors on the expression of drug-induced CPP lasted for at least 14 d. The inhibition of calpain without retrieval 6 h after retrieval or after exposure to an unpaired context had no effects on the expression of reward memory. Calpain inhibition after retrieval also decreased cocaine seeking in a self-administration model and this effect did not recover spontaneously after 28 d. Moreover, the knock-down of GRIP1 expression in the NAc core by lentivirus-mediated short-hairpin RNA blocked disruption of the reconsolidation of drug cue memories that was induced by calpain inhibitor treatment. These results suggest that calpain activity in the NAc core is crucial for the reconsolidation of drug reward memory via the regulation of GRIP1 expression. SIGNIFICANCE STATEMENT Calpain plays an important role in synaptic plasticity and long-term memory consolidation, however, its role in the reconsolidation of drug cue memory remains unknown. Using conditioned place preference and self-administration procedures, we found that exposure to drug-paired cues induced the

  4. Smoking impact on grip strength and fatigue resistance: implications for exercise and hand therapy practice.

    Science.gov (United States)

    Al-Obaidi, Saud; Al-Sayegh, Nowall; Nadar, Mohammed

    2014-07-01

    Grip strength assessment reflects on overall health of the musculoskeletal system and is a predictor of functional prognosis and mortality. The purpose of this study was: examine whether grip-strength and fatigue resistance are impaired in smokers, determine if smoking-related impairments (fatigue-index) can be predicted by demographic data, duration of smoking, packets smoked-per-day, and physical activity. Maximum isometric grip strength (MIGS) of male smokers (n = 111) and nonsmokers (n = 66) was measured before/after induced fatigue using Jamar dynamometer at 5-handle positions. Fatigue index was calculated based on percentage change in MIGS initially and after induced fatigue. Number of repetitions to squeeze the soft rubber ball to induce fatigue was significantly lower in smokers compared with nonsmokers (t = 10.6, P smoking status on MIGS scores was significantly different between smokers and nonsmokers after induced fatigue (β = -3.98, standard error = 0.59, P Smoking status was the strongest significant independent predictor of the fatigue-index. Smokers demonstrated reduced grip strength and fast fatigability in comparison with nonsmokers.

  5. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    NARCIS (Netherlands)

    Willems, Sara M.; Wright, D.J.; Day, Felix R.; Trajanoska, Katerina; Joshi, P.K.; Morris, John A.; Matteini, Amy M.; Garton, Fleur C.; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J.; Lotta, Luca A.; Miyamoto-Mikami, Eri; Rivas, Manuel A.; White, Tom; Loh, Po Ru; Aadahl, Mette; Amin, Najaf; Attia, John R.; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu Ching; Ciȩszczyk, Paweł; Derave, Wim; Eriksson, Karl Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D.; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K.; Sale, Craig; Schnurr, Theresia M.; Sessa, Francesco; Shrine, Nick; Tobin, Martin D.; Varley, Ian; Wain, Louise V.; Wray, Naomi R.; Lindgren, Cecilia M.; MacArthur, Daniel G.; Waterworth, Dawn M.; McCarthy, Mark I.; Pedersen, Oluf; Khaw, Kay Tee; Kiel, Douglas P.; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W.; North, Kathryn N.; Duijn, Van C.M.; Mather, Karen A.; Hansen, Torben; Hansson, Ola; Spector, Tim D.; Murabito, Joanne M.; Richards, J.B.; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R.B.; Wareham, Nick J.; Scott, Robert A.; Oei, Ling; Zheng, Hou Feng; Forgetta, Vincenzo; Leong, Aaron; Ahmad, Omar S.; Laurin, Charles; Mokry, Lauren E.; Ross, Stephanie; Elks, Cathy E.; Bowden, Jack; Warrington, Nicole M.; Murray, Anna; Ruth, Katherine S.; Tsilidis, Konstantinos K.; Medina-Gómez, Carolina; Estrada, Karol; Bis, Joshua C.; Chasman, Daniel I.; Demissie, Serkalem; Enneman, Anke W.; Hsu, Yi Hsiang; Ingvarsson, Thorvaldur; Kähönen, Mika; Kammerer, Candace; Lacroix, Andrea Z.; Li, Guo; Liu, Ching Ti; Liu, Yongmei; Lorentzon, Mattias; Mägi, Reedik; Mihailov, Evelin; Milani, Lili; Moayyeri, Alireza; Nielson, Carrie M.; Sham, Pack Chung; Siggeirsdotir, Kristin; Sigurdsson, Gunnar; Stefansson, Kari; Trompet, Stella; Thorleifsson, Gudmar; Vandenput, Liesbeth; Velde, Van Der Nathalie; Viikari, Jorma; Xiao, Su Mei; Zhao, Jing Hua; Evans, Daniel S.; Cummings, Steven R.; Cauley, Jane; Duncan, Emma L.; Groot, De Lisette C.P.G.M.; Esko, Tonu; Gudnason, Vilmundar; Harris, Tamara B.; Jackson, Rebecca D.; Jukema, J.W.; Ikram, Arfan M.A.; Karasik, David; Kaptoge, Stephen; Kung, Annie Wai Chee; Lehtimäki, Terho; Lyytikäinen, Leo Pekka; Lips, Paul; Luben, Robert; Metspalu, Andres; Meurs, van Joyce B.; Minster, Ryan L.; Orwoll, Erick; Oei, Edwin; Psaty, Bruce M.; Raitakari, Olli T.; Ralston, Stuart W.; Ridker, Paul M.; Robbins, John A.; Smith, Albert V.; Styrkarsdottir, Unnur; Tranah, Gregory J.; Thorstensdottir, Unnur; Uitterlinden, Andre G.; Zmuda, Joseph; Zillikens, M.C.; Ntzani, Evangelia E.; Evangelou, Evangelos; Ioannidis, John P.A.; Evans, David M.; Ohlsson, Claes

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of

  6. Is grip strength a predictor for total muscle strength in healthy children, adolescents, and young adults?

    NARCIS (Netherlands)

    Wind, Anne E.; Takken, Tim; Helders, Paul J. M.; Engelbert, Raoul H. H.

    2010-01-01

    The primary purpose of this study was to examine whether grip strength is related to total muscle strength in children, adolescents, and young adults. The second purpose was to provide reference charts for grip strength, which could be used in the clinical and research setting. This cross-sectional

  7. Sealed can of spent fuel

    International Nuclear Information System (INIS)

    Suzuki, Yasuyuki.

    1976-01-01

    Object: To provide a seal plug cover with a gripping portion fitted to a canning machine and a gripping portion fitted to a gripper of the same configuration as a fuel body for handling the fuel body so as to facilitate the handling work. Structure: A sealed can comprises a vessel and a seal plug cover, said cover being substantially in the form of a bottomed cylinder, which is slipped on the vessel and air-tightly secured by a fastening bolt between it and a flange. The spent fuel body is received into the vessel together with coolant during the step of canning operation. Said seal plug cover has two gripping portions, one for opening and closing the plug cover of the canning machine as an exclusive use member, the other being in the form of a hook-shaped peripheral groove, whereby the gripping portions may be effectively used using the same gripper when the spent fuel body is transported while being received in the sealed can or when the fuel body is removed from the sealed can. (Kawakami, Y.)

  8. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    Science.gov (United States)

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  9. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M.; Wright, Daniel J.; Day, Felix R.

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 1...

  10. EFFECT OF ECCENTRIC EXERCISE PROGRAMME ON PAIN AND GRIP STRENGTH FOR SUBJECTS WITH MEDIAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Mishra Prashant Akhilesh

    2014-04-01

    Full Text Available Background and Objective: Therapeutic eccentric exercise may provide both a structural and functional benefit during tendinopathy rehabilitation. The objective is to find the effect of eccentric exercises on improvement of pain and grip strength for subjects with Medial Epicondylitis. Method: Pre to post test experimental study design randomized thirty subjects with medial epicondylitis, 15 each into Group A and Group B. Group B subjects were treated with conventional therapy and Eccentric exercises. Group A subjects were treated with conventional therapy. Results: When means of post intervention were compared using Independent ‘t’ between groups there was no statistically significant difference in improvements obtained in VAS scores and grip strength. There was a statistically significant change in means of VAS score and Grip strength when means were analyzed by using Paired‘t’ test and Wilcoxon signed rank test within the groups with positive percentage of change. Conclusion: It is concluded that four weeks of Eccentric Exercise Programme combined with conventional therapy shown significant effect on improving pain and Grip strength, however the improvement obtained has no difference when compared with control conventional treatment for Subjects with Medial Epicondylitis.

  11. Influences of load characteristics on impaired control of grip forces in patients with cerebellar damage.

    Science.gov (United States)

    Brandauer, B; Timmann, D; Häusler, A; Hermsdörfer, J

    2010-02-01

    Various studies showed a clear impairment of cerebellar patients to modulate grip force in anticipation of the loads resulting from movements with a grasped object. This failure corroborated the theory of internal feedforward models in the cerebellum. Cerebellar damage also impairs the coordination of multiple-joint movements and this has been related to deficient prediction and compensation of movement-induced torques. To study the effects of disturbed torque control on feedforward grip-force control, two self-generated load conditions with different demands on torque control-one with movement-induced and the other with isometrically generated load changes-were directly compared in patients with cerebellar degeneration. Furthermore the cerebellum is thought to be more involved in grip-force adjustment to self-generated loads than to externally generated loads. Consequently, an additional condition with externally generated loads was introduced to further test this hypothesis. Analysis of 23 patients with degenerative cerebellar damage revealed clear impairments in predictive feedforward mechanisms in the control of both self-generated load types. Besides feedforward control, the cerebellar damage also affected more reactive responses when the externally generated load destabilized the grip, although this impairment may vary with the type of load as suggested by control experiments. The present findings provide further support that the cerebellum plays a major role in predictive control mechanisms. However, this impact of the cerebellum does not strongly depend on the nature of the load and the specific internal forward model. Contributions to reactive (grip force) control are not negligible, but seem to be dependent on the physical characteristics of an externally generated load.

  12. A novel mechanism of hippocampal LTD involving muscarinic receptor-triggered interactions between AMPARs, GRIP and liprin-α

    Directory of Open Access Journals (Sweden)

    Dickinson Bryony A

    2009-06-01

    Full Text Available Abstract Background Long-term depression (LTD in the hippocampus can be induced by activation of different types of G-protein coupled receptors, in particular metabotropic glutamate receptors (mGluRs and muscarinic acethycholine receptors (mAChRs. Since mGluRs and mAChRs activate the same G-proteins and isoforms of phospholipase C (PLC, it would be expected that these two forms of LTD utilise the same molecular mechanisms. However, we find a distinct mechanism of LTD involving GRIP and liprin-α. Results Whilst both forms of LTD require activation of tyrosine phosphatases and involve internalisation of AMPARs, they use different molecular interactions. Specifically, mAChR-LTD, but not mGluR-LTD, is blocked by peptides that inhibit the binding of GRIP to the AMPA receptor subunit GluA2 and the binding of GRIP to liprin-α. Thus, different receptors that utilise the same G-proteins can regulate AMPAR trafficking and synaptic efficacy via distinct molecular mechanisms. Conclusion Our results suggest that mAChR-LTD selectively involves interactions between GRIP and liprin-α. These data indicate a novel mechanism of synaptic plasticity in which activation of M1 receptors results in AMPAR endocytosis, via a mechanism involving interactions between GluA2, GRIP and liprin-α.

  13. Serotonergic-postsynaptic receptors modulate gripping-induced immobility episodes in male taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, M C; Ita, M L

    2009-09-01

    The Taiep rat is a myelin mutant with a motor syndrome characterized by tremor, ataxia, immobility, epilepsy, and paralysis. The rat shows a hypomyelination followed by a progressive demyelination. During immobilities taiep rats show a REM-like sleep pattern and a disorganized sleep-wake pattern suggesting taiep rats as a model of narcolepsy-cataplexy. Our study analyzed the role of postsynaptic serotonin receptors in the expression of gripping-induced immobility episodes (IEs) in 8-month-old male taiep rats. The specific postsynaptic serotonin agonist +/-1-(2,5-dimethoxy-4-iodoamphetamine hydrochloride (+/-DOI) decreased the frequency of gripping-induced IEs, but that was not the case with alpha-methyl-serotonin maleate (alpha-methyl-5HT), a nonspecific postsynaptic agonist. Although the serotonin antagonists, ketanserine and metergoline, produced a biphasic effect, first a decrease followed by an increase with higher doses, similar effects were obtained with a mean duration of gripping-induced IEs. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which serotonin-reuptake inhibitors improve cataplexy, particularly in long-term treatment that could change the serotonin receptor levels. Polysomnographic recordings showed an increase in the awakening time and a decrease in the slow wave and rapid eye movement sleep concomitant with a decrease in immobilities after use of +/-DOI, this being stronger with the highest dose. Taken together, our results show that postsynaptic serotonin receptors are involved in the modulation in gripping-induced IEs caused by the changes in the organization of the sleep-wake cycle in taiep rats. It is possible that specific agonists, without side effects, could be a useful treatment in human narcoleptic patients. 2009 Wiley-Liss, Inc.

  14. Functional relationship between dominant and non-dominant hand in motor task - hand grip strength endurance

    Directory of Open Access Journals (Sweden)

    Kljajić Dragana

    2012-01-01

    Full Text Available The aim of this study was to determine the functional relationship between dominant and non-dominant hand in the strength endurance motor task - hand grip, in the referent population of healthy and young persons. For the purpose of the research we have implemented the method of isometric dynamometry and standardized hand grip test. The study included 48 participants, 23 of them being of female and 25 of male gender. The analysis of variance (ANOVA was used to determine the difference between the sets of variables in the function of gender and functional dimorphism, while the Bonferroni criterion was applied to determine the differences between pairs of individual variables. The difference between the maximum hand grip of dominant and non-dominant hand in female participants amounted to 9.28%, and in male ones 7.39% in favor of the dominant hand. There is no statistically significant difference between nondominant and dominant hand regarding the force endurance time aspect at 30%, 50% and 80% out of the maximum hand grip level, as well as at the absolute and relative force impulse indicators as an endurance measure. The value of gender dimorphism in relation to the absolute indicators of force momentum at 30%, 50% and 80% out of the maximum hand grip level in female participants is 0.9714, 0.9145, 0.9301, and in male participants 0.9515, 0.8264 and 0.8606. The force momentum indicators value at 30%, 50% and 80% out of the maximum hand grip level in female participants is ImpF30%=21167.58±6923.67 Ns, ImpF50%=10846.94±3800.56 Ns and ImpF80%=5438.46±1993.12 Ns, and in male participants ImpF30%=17734.03±6881.92 Ns, ImpF50%=13903.61±3437.76 Ns and ImpF80%=5117.53±1894.78 Ns. The obtained results can be used as the criteria for further research in special education and rehabilitation, medical and professional rehabilitation.

  15. Clinical experience with arthroscopically-assisted repair of peripheral triangular fibrocartilage complex tears in adolescents--technique and results.

    Science.gov (United States)

    Farr, Sebastian; Zechmann, Ulrike; Ganger, Rudolf; Girsch, Werner

    2015-08-01

    The purpose of this study was to report our preliminary results after arthroscopically-assisted repair of peripheral triangular fibrocartilage complex (TFCC) tears in adolescent patients. All children and adolescents who underwent arthroscopically-assisted repair of a Palmer 1B tear were identified and prospectively evaluated after a mean follow-up of 1.3 years. The postoperative assessment included documentation of clinical parameters, pain score (visual analogue scale, VAS), grip strength and completion of validated outcome scores (Modified Mayo Wrist Score, MMWS; Disabilities of the Arm, Shoulder and Hand Inventory, DASH). A total of 12 patients (four males, eight females) with a mean age of 16.3 years at the time of surgery were evaluated. The mean VAS decreased significantly from 7.0 to 1.7 after the procedure. We observed a significant increase of the MMWS after surgery; however, MMWS was still significantly lower at final follow-up when compared to the contralateral side. A mean postoperative DASH score of 16 indicated an excellent outcome after the procedure. DASH Sports and Work Modules showed fair and good overall outcomes in the short-term, respectively. Grip strength averaged 86 % of the contralateral side at final follow-up, with no significant difference being found between both sides. Arthroscopically-assisted repair of peripheral TFCC tears in adolescents provided predictable pain relief and markedly improved functional outcome scores. Concomitant pathologies may have to be addressed at the same time to eventually achieve a satisfactory outcome. Sports participation, however, may be compromised in the short-term and should therefore be resumed six months postoperatively.

  16. The properties and interrelationships of various force-time parameters during maximal repeated rhythmic grip.

    Science.gov (United States)

    Nakada, Masakatsu; Demura, Shinichi; Yamaji, Shunsuke

    2007-01-01

    The purpose of this study was to examine the properties and interrelationships of various force-time parameters including the inflection point for the rate of decline in force during a maximal repeated rhythmic grip. Fifteen healthy males (age M=21.5, SD=2.1 yr, height M=172.4, SD=5.7 cm, body mass M=68.2, SD=9.2 kg) participated in this study. Subjects performed a maximal repeated rhythmic grip with maximal effort with a target frequency of 30 grip.min(-1) for 6 min. The force value decreased linearly and markedly until about 70% of maximal strength for about 55 s after the onset of a maximal repeated rhythmic grip, and then decreased moderately. Because all parameters showed fair or good correlations between 3 min and 6 min, they are considered to be able to sufficiently evaluate muscle endurance for 3 min instead of 6 min. However, there were significant differences between 3 min and 6 min in the integrated area, the final force, the rate of the decrement constant (k) fitting the force decreasing data to y=ae(-kx)+b and the force of maximal difference between the force and a straight line from peak force to the final force. Their parameters may vary generally by the length of a steady state, namely, a measurement time. The final force value before finishing and the rate of the decrement constant (k) reflect the latter phase during a maximal repeated rhythmic grip. Although many parameters show relatively high mutual relationships, the rate constant (k) shows relatively low correlations with other parameters. We inferred that decreasing the time until 80% of maximal strength and the amount of the decrement force for the first 1 min reflect a linear decrease in the initial phase.

  17. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M; Wright, Daniel J.; Day, Felix R

    2017-01-01

    with involvement of psychomotor impairment (PEX14, LRPPRC and KANSL1). Mendelian randomization analyses are consistent with a causal effect of higher genetically predicted grip strength on lower fracture risk. In conclusion, our findings provide new biological insight into the mechanistic underpinnings of grip...... strength and the causal role of muscular strength in age-related morbidities and mortality....

  18. Grip strength and lower limb extension power in 19-72-year-old Danish men and women

    DEFF Research Database (Denmark)

    Aadahl, Mette; Beyer, Nina; Linneberg, Allan

    2011-01-01

    To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition.......To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition....

  19. An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback.

    Science.gov (United States)

    Brown, Jeremy D; Paek, Andrew; Syed, Mashaal; O'Malley, Marcia K; Shewokis, Patricia A; Contreras-Vidal, Jose L; Davis, Alicia J; Gillespie, R Brent

    2015-11-25

    Haptic display technologies are well suited to relay proprioceptive, force, and contact cues from a prosthetic terminal device back to the residual limb and thereby reduce reliance on visual feedback. The ease with which an amputee interprets these haptic cues, however, likely depends on whether their dynamic signal behavior corresponds to expected behaviors-behaviors consonant with a natural limb coupled to the environment. A highly geared motor in a terminal device along with the associated high back-drive impedance influences dynamic interactions with the environment, creating effects not encountered with a natural limb. Here we explore grasp and lift performance with a backdrivable (low backdrive impedance) terminal device placed under proportional myoelectric position control that features referred haptic feedback. We fabricated a back-drivable terminal device that could be used by amputees and non-amputees alike and drove aperture (or grip force, when a stiff object was in its grasp) in proportion to a myoelectric signal drawn from a single muscle site in the forearm. In randomly ordered trials, we assessed the performance of N=10 participants (7 non-amputee, 3 amputee) attempting to grasp and lift an object using the terminal device under three feedback conditions (no feedback, vibrotactile feedback, and joint torque feedback), and two object weights that were indiscernible by vision. Both non-amputee and amputee participants scaled their grip force according to the object weight. Our results showed only minor differences in grip force, grip/load force coordination, and slip as a function of sensory feedback condition, though the grip force at the point of lift-off for the heavier object was significantly greater for amputee participants in the presence of joint torque feedback. An examination of grip/load force phase plots revealed that our amputee participants used larger safety margins and demonstrated less coordination than our non-amputee participants

  20. Initial Effect of Taping Technique on Wrist Extension and Grip Strength and Pain of Individuals with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Alireza Shamsoddini

    2010-04-01

    Full Text Available Objectives: Aim of this study is to investigate the initial effect of taping technique on wrist extension and grip strength and pain of Individuals with tennis elbow. Methods: fifteen patients (10 men and 5 women with 42.53 years on their dominant arm participated in this study. Outcome measures were wrist extension and grip strength and pain taken before and immediately after application of tape. The unaffected arm served as a control. Used of hand-held dynamometer and jammar dynamometer for evaluated of wrist extension and grip strength. Also, visual analog scale (VAS used for evaluated of pain Results: Among the variables, significant differences were found in wrist extension strength between effected and unaffected arm (P=0.006. Also, changes in grip strength shows statically significant improve in effect arm than unaffected arm (P=0.001. Changes in pain in impaired arm were positive. Discussion: Taping technique, as applied in this study demonstrated an impressive effect on wrist extension and grip strength and pain in individuals with tennis elbow. Therefore, it is recommended that this method may be useful in the management of this condition during exercise and functional rehabilitation.

  1. Gripped by movies: From story-world to artifact absorption

    NARCIS (Netherlands)

    Doicaru, M.M.

    2016-01-01

    That movies are a great source of entertainment seems to be common sense. But how exactly movies manage to get large audiences absorbed, or what is their gripping tool is still a mystery. Research makes use of different concepts pointing to narrative absorption, but it is not clear how they differ

  2. Improved Friction Joint With Self-Locking Grips

    DEFF Research Database (Denmark)

    Costache, Andrei; Glejbøl, Kristian; Sivebæk, Ion Marius

    2016-01-01

    Flexible risers are used in the oil industry to transport liquids and gas from the seafloorto extraction and production equipment at the sea surface. Ongoing research aims at using composite materials instead of steel, in order to reduce weight and increase stiffness. Ensuring an optimal load......-depth understanding of the influence between friction, geometrical parameters,and performance, making it possible to optimize the design. Results show that this grip system offers immediate technical applications, in a variety of conditions....

  3. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    Science.gov (United States)

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused

  4. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  5. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    Science.gov (United States)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  6. Estimating thumb–index finger precision grip and manipulation potential in extant and fossil primates

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.

    2015-01-01

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134

  7. Grip Strength as an Indicator of Health-Related Quality of Life in Old Age-A Pilot Study.

    Science.gov (United States)

    Musalek, Christina; Kirchengast, Sylvia

    2017-11-24

    Over the last century life expectancy has increased dramatically nearly all over the world. This dramatic absolute and relative increase of the old aged people component of the population has influenced not only population structure but also has dramatic implications for the individuals and public health services. The aim of the present pilot study was to examine the impact of physical well-being assessed by hand grip strength and social factors estimated by social contact frequency on health-related quality of life among 22 men and 41 women ranging in age between 60 and 94 years. Physical well-being was estimated by hand grip strength, data concerning subjective wellbeing and health related quality of life were collected by personal interviews based on the WHOQOL-BREF questionnaires. Number of offspring and intergenerational contacts were not related significantly to health-related quality of life, while social contacts with non-relatives and hand grip strength in contrast had a significant positive impact on health related quality of life among old aged men and women. Physical well-being and in particular muscle strength-estimated by grip strength-may increase health-related quality of life and is therefore an important source for well-being during old age. Grip strength may be used as an indicator of health-related quality of life.

  8. Normative static grip strength of population of Turkey, effects of various factors and a comparison with international norms.

    Science.gov (United States)

    Ekşioğlu, Mahmut

    2016-01-01

    Normative data are of importance in ergonomics and clinical settings. Applying normative data internationally is questionable. To this end, this study aimed to establish gender- and age-specific reference values for static (isometric) hand grip strength of normal population of Turkey with special regard to occupational demand, and compare them with the international norms. The secondary aims were to investigate the effects of gender, age-group, weight-group, job-group, hand and several anthropometric variables on static grip strength. A sample of 211 (128 male and 83 female) volunteers aged between 18 and 69 with various occupations participated in the study. Grip strength data were collected using a Jamar dynamometer with standard testing position, protocol and instructions. The mean and std deviation of maximum voluntary static grip strength values (in N) for dominant and non-dominant hands respectively were 455.2 ± 73.6 and 441.5 ± 72.6 for males, and 258 ± 46.1 and 246.2 ± 49.1 for females. The mean female strength was about 57% of the mean male strength value for both dominant and non-dominant hands. There was a curvilinear relationship of grip strength to age, significant differences between genders, hands, and some age-groups, and a correlation to height, body-mass, BMI and hand dimensions depending on the gender. The comparisons with the norms of other world populations indicate that there are cross-national grip strength variations among some nations but not all. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  9. An Overview on Gripping Force Measurement at the Micro and Nano-Scales Using Two-Fingered Microrobotic Systems

    Directory of Open Access Journals (Sweden)

    Mokrane Boudaoud

    2014-03-01

    Full Text Available Two-fingered micromanipulation systems with an integrated force sensor are widely used in robotics to sense and control gripping forces at the micro and nano-scales. They became of primary importance for an efficient manipulation and characterization of highly deformable biomaterials and nanostructures. This paper presents a chronological overview of gripping force measurement using two-fingered micromanipulation systems. The work summarizes the major achievements in this field from the early 90s to the present, focusing in particular on the evolution of measurement technologies regarding the requirements of microrobotic applications. Measuring forces below the microNewton for the manipulation of highly deformable materials, embedding force sensors within microgrippers to increase their dexterity, and reducing the influence of noise to improve the measurement resolution are among the addressed challenges. The paper shows different examples of how these challenges have been addressed. Resolution, operating range and signal/noise ratio of gripping force sensors are reported and compared. A discussion about force measurement technologies and gripping force control is performed and future trends are highlighted.

  10. Transcranial direct current stimulation over multiple days enhances motor performance of a grip task.

    Science.gov (United States)

    Fan, Julie; Voisin, Julien; Milot, Marie-Hélène; Higgins, Johanne; Boudrias, Marie-Hélène

    2017-09-01

    Recovery of handgrip is critical after stroke since it is positively related to upper limb function. To boost motor recovery, transcranial direct current stimulation (tDCS) is a promising, non-invasive brain stimulation technique for the rehabilitation of persons with stroke. When applied over the primary motor cortex (M1), tDCS has been shown to modulate neural processes involved in motor learning. However, no studies have looked at the impact of tDCS on the learning of a grip task in both stroke and healthy individuals. To assess the use of tDCS over multiple days to promote motor learning of a grip task using a learning paradigm involving a speed-accuracy tradeoff in healthy individuals. In a double-blinded experiment, 30 right-handed subjects (mean age: 22.1±3.3 years) participated in the study and were randomly assigned to an anodal (n=15) or sham (n=15) stimulation group. First, subjects performed the grip task with their dominant hand while following the pace of a metronome. Afterwards, subjects trained on the task, at their own pace, over 5 consecutive days while receiving sham or anodal tDCS over M1. After training, subjects performed de novo the metronome-assisted task. The change in performance between the pre and post metronome-assisted task was used to assess the impact of the grip task and tDCS on learning. Anodal tDCS over M1 had a significant effect on the speed-accuracy tradeoff function. The anodal tDCS group showed significantly greater improvement in performance (39.28±15.92%) than the sham tDCS group (24.06±16.35%) on the metronome-assisted task, t(28)=2.583, P=0.015 (effect size d=0.94). Anodal tDCS is effective in promoting grip motor learning in healthy individuals. Further studies are warranted to test its potential use for the rehabilitation of fine motor skills in stroke patients. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Associations between aging-related changes in grip strength and cognitive function in older adults: A systematic review.

    Science.gov (United States)

    Zammit, Andrea R; Robitaille, Annie; Piccinin, Andrea; Muniz-Terrera, Graciela; Hofer, Scott M

    2018-03-08

    Grip strength and cognitive function reflect upper body muscle strength and mental capacities. Cross-sectional research has suggested that in old age these two processes are moderately to highly associated, and that an underlying common cause drives this association. Our aim was to synthesize and evaluate longitudinal research addressing whether changes in grip strength are associated with changes in cognitive function in healthy older adults. We systematically reviewed English-language research investigating the longitudinal association between repeated measures of grip strength and of cognitive function in community-dwelling older adults to evaluate the extent to which the two indices decline concurrently. We used four search engines: Embase, PsychINFO, PubMed, and Web of Science. Of 459 unique citations, 6 met our full criteria: 4 studies reported a longitudinal association between rates of change in grip strength and cognitive function in older adults, 2 of which reported the magnitudes of these associations as ranging from low to moderate; 2 studies reported significant cross-sectional but not longitudinal associations among rates of change. All studies concluded that cognitive function and grip strength declined, on average, with increasing age, although with little to no evidence for longitudinal associations among rates of change. Future research is urged to expand the study of physical and cognitive associations in old age using a within-person and multi-study integrative approach to evaluate the reliability of longitudinal results with greater emphasis on the magnitude of this association.

  12. Grip Strength Is Associated With Cognitive Performance in Schizophrenia and the General Population: A UK Biobank Study of 476559 Participants.

    Science.gov (United States)

    Firth, Joseph; Stubbs, Brendon; Vancampfort, Davy; Firth, Josh A; Large, Matthew; Rosenbaum, Simon; Hallgren, Mats; Ward, Philip B; Sarris, Jerome; Yung, Alison R

    2018-04-19

    Handgrip strength may provide an easily-administered marker of cognitive functional status. However, further population-scale research examining relationships between grip strength and cognitive performance across multiple domains is needed. Additionally, relationships between grip strength and cognitive functioning in people with schizophrenia, who frequently experience cognitive deficits, has yet to be explored. Baseline data from the UK Biobank (2007-2010) was analyzed; including 475397 individuals from the general population, and 1162 individuals with schizophrenia. Linear mixed models and generalized linear mixed models were used to assess the relationship between grip strength and 5 cognitive domains (visual memory, reaction time, reasoning, prospective memory, and number memory), controlling for age, gender, bodyweight, education, and geographical region. In the general population, maximal grip strength was positively and significantly related to visual memory (coefficient [coeff] = -0.1601, standard error [SE] = 0.003), reaction time (coeff = -0.0346, SE = 0.0004), reasoning (coeff = 0.2304, SE = 0.0079), number memory (coeff = 0.1616, SE = 0.0092), and prospective memory (coeff = 0.3486, SE = 0.0092: all P reasoning (P > .1). Grip strength is significantly associated with cognitive functioning in the general population and individuals with schizophrenia, particularly for working memory and processing speed. Future research should establish directionality, examine if grip strength also predicts functional and physical health outcomes in schizophrenia, and determine whether interventions which improve muscular strength impact on cognitive and real-world functioning.

  13. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  14. Effect of Insoles with a Toe-Grip Bar on Toe Function and Standing Balance in Healthy Young Women: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Hideki Nakano

    2017-01-01

    Full Text Available Objective. The aim of this randomized controlled study was to investigate the effects of insoles with a toe-grip bar on toe function and standing balance in healthy young women. Methods. Thirty female subjects were randomly assigned to an intervention group or a control group. The intervention group wore shoes with insoles with a toe-grip bar. The control group wore shoes with general insoles. Both groups wore the shoes for 4 weeks, 5 times per week, 9 hours per day. Toe-grip strength, toe flexibility, static balance (total trajectory length and envelope area of the center of pressure, and dynamic balance (functional reach test were measured before and after the intervention. Results. Significant interactions were observed for toe-grip strength and toe flexibility (F=12.53, p<0.01; F=5.84, p<0.05, resp., with significant improvement in the intervention group compared with that in the control group. Post hoc comparisons revealed that both groups showed significant improvement in toe-grip strength (p<0.01 and p<0.05, resp., with higher benefits observed for the intervention group (p<0.01. Conversely, no significant interaction was observed in the total trajectory length, envelope area, and functional reach test. Conclusions. This study suggests that insoles with a toe-grip bar contribute to improvements in toe-grip strength and toe flexibility in healthy young women.

  15. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment

    DEFF Research Database (Denmark)

    Filteau, Suzanne; PrayGod, G; Woodd, Susannah L

    2017-01-01

    OBJECTIVES: Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. METHODS: The study...... involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index .... CONCLUSIONS: In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment...

  16. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    International Nuclear Information System (INIS)

    Mohamad, M; Ismail, S S; Mardan, N H

    2017-01-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance. (paper)

  17. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  18. Grip strength and quality of life in the second half of life: hope as a moderator.

    Science.gov (United States)

    Gum, Amber M; Segal-Karpas, Dikla; Avidor, Sharon; Ayalon, Liat; Bodner, Ehud; Palgi, Yuval

    2017-09-28

    The purpose of the current study was to investigate grip strength, hope, and their interaction as predictors of quality of life four years later in a nationally representative sample of older adults. Data were derived from the first (2005-2006) and second wave (2009) of the Israeli component of the Survey of Health Ageing and Retirement in Europe (SHARE; N = 344). Hope was measured by three items from the Hope   Scale, and quality of life was measured by the CASP-12 (Control, Autonomy, Self-Realization, and Pleasure). Multiple regression analyses were conducted. Grip strength at T1 predicted QoL in T2, but hope was not a significant predictor. Furthermore, hope moderated the effect of handgrip on QoL, such that the effect was weaker for higher levels of hope. As hypothesized, hope acted as a moderator, such that poor grip strength was associated with worse QoL for less hopeful older adults, but grip strength was not associated with QoL for more hopeful older adults. Findings are consistent with a theoretical conceptualization of hope as a buffer between physical challenges and negative outcomes like QoL. Encouraging a hopeful perspective could enhance QoL for older adults with decreased muscle strength.

  19. The interdigital brace and other grips for termite nest perforation by chimpanzees of the Goualougo Triangle, Republic of Congo.

    Science.gov (United States)

    Lesnik, Julie J; Sanz, Crickette M; Morgan, David B

    2015-06-01

    Studies of chimpanzee termite foraging enlighten our understanding of early hominin tool use not only by modeling the cognitive ability of our ancestors but also by emphasizing the possible role of social insects in the hominin diet. The chimpanzees of the Goualougo Triangle are known to have one of the largest and most complex tool repertoires reported for wild chimpanzees. One tool set habitually used by this population includes a perforating tool to penetrate the hard outer crust of elevated termite nests before fishing for termite prey with an herbaceous stem. Here, we report the variation present in the grips used on the perforating tool. Our analysis of video recordings of chimpanzee visitation to termite nests over a 3-year period shows that these chimpanzees use a variety of grips to navigate the challenges encountered in opening a termite nest. For situations in which the soil is most hardened, perforating requires force and a power grip is often used. When the soil in the passageway is loose, precision grips are suitable for the task. One of the preferred grips reported here is an interdigital brace, which has previously been described in studies of how some people hold a pencil. In this study, for the first time, the interdigital brace has been thoroughly described for chimpanzees. The various strategies and grips used during perforation emphasize the importance of termites as a nutritional resource that should be considered more strongly as a food used by early hominins. © 2015 Wiley Periodicals, Inc.

  20. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields.

    Science.gov (United States)

    Leib, Raz; Karniel, Amir; Nisky, Ilana

    2015-05-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain. Copyright © 2015 the American Physiological Society.

  1. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.

    Science.gov (United States)

    Lockie, Robert G; Callaghan, Samuel J; Moreno, Matthew R; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Stokes, John J; Giuliano, Dominic V; Lazar, Adrina; Davis, DeShaun L; Orjalo, Ashley J

    2017-12-01

    The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  2. The contribution of prenatal environment and genetic factors to the association between birth weight and adult grip strength.

    Directory of Open Access Journals (Sweden)

    Charlotte L Ridgway

    2011-03-01

    Full Text Available Low birth weight has been associated with reduced hand grip strength, which is a marker of future physical function and disease risk. The aim of this study was to apply a twin pair approach, using both 'individual' data and 'within-pair' differences, to investigate the influence of birth weight on hand grip strength and whether this association may be mediated through fat free mass (FFM. Participants from the East Flanders Prospective Twin Survey were included if born without congenital abnormalities, birth weight >500 g and ≥22 weeks of gestation. Follow up in adulthood (age: 18-34 year, included anthropometric measures and hand grip (n = 783 individuals, n = 326 same-sex twin pairs. Birth weight was positively associated with hand grip strength (β = 2.60 kg, 95% CI 1.52, 3.67, p<0.001 and FFM (β = 4.2, 95% CI 3.16, 5.24, p<0.001, adjusted for gestational age, sex and adult age. Using 'within-pair' analyses, the birth weight hand grip association was significant in DZ men only (β = 5.82, 95% CI 0.67, 10.97, p = 0.028, which was attenuated following adjustment for FFM. Within-pair birth weight FFM associations were most pronounced in DZ men (β = 11.20, 95% CI 7.18, 15.22, p<0.001. Our 'individual' analyses show that higher birth weight is associated with greater adult hand grip strength, which is mediated through greater adult FFM. The 'within-pair' analyses confirm this observation and furthermore show that, particularly in men, genetic factors may in part explain this association, as birth weight differences in DZ men result in greater differences in adult strength and FFM.

  3. Interactive effects of music tempi and intensities on grip strength and subjective affect.

    Science.gov (United States)

    Karageorghis, C I; Cheek, P; Simpson, S D; Bigliassi, M

    2018-03-01

    Pretask music is widely used by athletes albeit there is scant empirical evidence to support its use. The present study extended a line of work into pretask music by examining the interactive effects of music tempo and intensity (volume) on the performance of a simple motor skill and subjective affect. A 2 × 2 within-subjects factorial design was employed with an additional no-music control, the scores from which were used as a covariate. A sample of 52 male athletes (M age  = 26.1 ± 4.8 years) was exposed to five conditions: fast/loud (126 bpm/80 dBA), fast/quiet (126 bpm/70 dBA), slow/loud (87 bpm/80 dBA), slow/quiet (87 bpm/70 dBA) music, and a no-music control. Dependent variables were grip strength, measured with a handgrip dynamometer, and subjective affect, assessed by use of the Affect Grid. The tempo and intensity components of music had interactive effects for grip strength but only main effects for subjective affect. Fast-tempo music played at a high intensity yielded the highest grip strength, while fast-tempo music played at a low-intensity resulted in much lower grip strength (M diff.  = -1.11 Force kg). For affective valence, there were main effects of tempo and intensity, with fast and loud music yielding the highest scores. For affective arousal, there was no difference between tempi although there was between intensities, with the high-intensity condition yielding higher scores. The present findings indicate the utility of fast/loud pretask music in enhancing affective valence and arousal in preparation for a simple or gross motor task. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. The effects of cold immersion and hand protection on grip strength.

    Science.gov (United States)

    Vincent, M J; Tipton, M J

    1988-08-01

    The maximal voluntary grip strength (MVGS) of male volunteers was examined following a series of five intermittent 2 min cold water (5 degrees C) immersions of the unprotected hand or forearm. MVGS changes due to wearing a protective glove were also investigated. The surface electrical activity over the hand flexor muscles was recorded, as was the skin temperature of the hand and forearm. MVGS decreased significantly (p less than 0.01) following hand immersions (16%) and forearm immersion (13%). The majority of these reductions occurred during the first 2-min period of immersion. The effect of wearing a glove after unprotected hand cooling also produced significant (p less than 0.01) MVGS reductions which averaged 14%. These reductions were in addition to those caused by hand cooling. We conclude that both hand and forearm protection are important for the maintenance of hand-grip strength following cold water immersion.

  5. A Monte Carlo-tuned model of the flow in the NorthGRIP area

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Dahl-Jensen, Dorthe

    2002-01-01

    The North Greenland Icecore Project (NorthGRIP) drill site was chosen in order to obtain a good Eemian record. At the present depth, 3001m, the Eemian interstadial has yet to be seen. Clearly the flow in this area is poorly understood and needs further investigation. After a review of specific...... no Eemian is observed is a high basal melt rate (2.7mm/a). The melting is a consequence of a higher geothermal heat flux than the expected 51mW/m^2 of the Precambrian shield. From our analyses it is concluded that the geothermal heat flux at NorthGRIP is 98mW/m^2.The high basalmelt rate also gives rise...

  6. Progress on the interface between UPP and CPRHS (Cask and Plug Remote Handling System) tractor/gripping tool for ITER

    International Nuclear Information System (INIS)

    Rosa, Elena V.; Rios, Luis; Queral, Vicente

    2013-01-01

    Highlights: ► UPP interface requirements in the plug RH extraction/insertion for ITER. ► Analyze of maximum misalignment between port duct and port cell. ► Friction study between plug skids and VV port/ramp rails during the plug transfer. ► Definition of the tolerance in the plug skids to avoid the plug jamming. ► Concepts of gripping tools based on one gripping point and avoiding force feedback. -- Abstract: EFDA finances a training programme called Goal Oriented Training Programme for Remote Handling (GOT RH), whose goal is to train engineers in Remote Handling for ITER. As part of this training programme, the conceptual design of the mechanical interface between Upper Port Plug (UPP) and Cask and Plug Remote Handling System (CPRHS) as well as the conceptual design of the needed tools for UPP Remote Handling is carried out. The paper presents the conceptual design of the UPP/Gripping Tool Interface. This includes the conceptual design of the gripping tool for introducing/removing the UPP in/from the ITER port and the mechanical features on both sides of the UPP/Gripping Tool Interface (e.g. alignment features, mechanical connectors, fasteners). In order to develop the design of the interface between UPP and CPRHS it is necessary to first identify the functional requirements of the Transfer Cask System (TCS) and the CPRHS, such as required degrees of freedom (DoF), required performances of system, geometrical constraints, loading conditions, alignment requirements, RAMI requirements. These requirements are the input data for the design of the interface between UPP and gripping tool and some of them are also described in the paper

  7. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  8. Finger pad friction and its role in grip and touch.

    Science.gov (United States)

    Adams, Michael J; Johnson, Simon A; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-03-06

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick-slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function.

  9. Criterion-Referenced Values of Grip Strength and Usual Gait Speed Using Instrumental Activities of Daily Living Disability as the Criterion.

    Science.gov (United States)

    Lee, Meng-Chih; Hsu, Chih-Cheng; Tsai, Yi-Fen; Chen, Ching-Yu; Lin, Cheng-Chieh; Wang, Ching-Yi

    Current evidence suggests that grip strength and usual gait speed (UGS) are important predictors of instrumental activities of daily living (IADL) disability. Knowing the optimum cut points of these tests for discriminating people with and without IADL disability could help clinicians or researchers to better interpret the test results and make medical decisions. The purpose of this study was to determine the cutoff values of grip strength and UGS for best discriminating community-dwelling older adults with and without IADL disability, separately for men and women, and to investigate their association with IADL disability. We conducted secondary data analysis on a national dataset collected in the Sarcopenia and Translational Aging Research in Taiwan (START). The data used in this study consisted of health data of 2420 community-dwelling older adults 65 years and older with no history of stroke and with complete data. IADL disability was defined as at least 1 IADL item scored as "need help" or "unable to perform." Receiver operating characteristics analysis was used to estimate the optimum grip strength and UGS cut points for best discriminating older adults with/without IADL disability. The association between each physical performance (grip strength and UGS) and IADL disability was assessed with odds ratios (ORs). With IADL disability as the criterion, the optimal cutoff values of grip strength were 28.7 kg for men and 16.0 kg for women, and those for UGS were 0.76 m/s for men and 0.66 m/s for women. The grip strength test showed satisfactory discriminant validity (area under the curve > 0.7) in men and a strong association with IADL disability (OR > 4). Our cut points using IADL disability as the criterion were close to those indicating frailty or sarcopenia. Our reported cutoffs can serve as criterion-referenced values, along with those previously determined using different indicators, and provide important landmarks on the performance continua of older adults

  10. Gripping characteristics of an electromagnetically activated magnetorheological fluid-based gripper

    Science.gov (United States)

    Choi, Young T.; Hartzell, Christine M.; Leps, Thomas; Wereley, Norman M.

    2018-05-01

    The design and test of a magnetorheological fluid (MRF)-based universal gripper (MR gripper) are presented in this study. The MR gripper was developed to have a simple design, but with the ability to produce reliable gripping and handling of a wide range of simple objects. The MR gripper design consists of a bladder mounted atop an electromagnet, where the bladder is filled with an MRF, which was formulated to have long-term stable sedimentation stability, that was synthesized using a high viscosity linear polysiloxane (HVLP) carrier fluid with a carbonyl iron particle (CIP) volume fraction of 35%. Two bladders were fabricated: a magnetizable bladder using a magnetorheological elastomer (MRE), and a passive (non-magnetizable) silicone rubber bladder. The holding force and applied (initial compression) force of the MR gripper for a bladder fill volume of 75% were experimentally measured, for both magnetizable and passive bladders, using a servohydraulic material testing machine for a range of objects. The gripping performance of the MR gripper using an MRE bladder was compared to that of the MR gripper using a passive bladder.

  11. Relationship among maximal grip, throwing velocity and anthropometric parameters in elite water polo players.

    Science.gov (United States)

    Ferragut, C; Vila, H; Abraldes, J A; Argudo, F; Rodriguez, N; Alcaraz, P E

    2011-03-01

    As independent aspects, body size, body composition, and physiological performance of elite athletes have aroused the interest of sports scientists but, unfortunately, studies that combine these aspects are scarcely avalaible in water polo. The aim of the present study was to: 1) to develop an anthropometric profile of highly skilled male Water Polo players, and 2) to identify significant relationships between these features and overhead throwing velocity in highly skilled male water polo players. Thirteen male water polo players, with a mean age of 26.10±4.82, were recruited from the Spanish Water Polo team and an anthropometric assessment on all of them was carried out. Throwing velocity was evaluated in three different situations from the 5 m-penalty line on the center of the water polo goal: A) throwing without a defender nor a goalkeeper; B) throwing with a goalkeeper only, and C) 3) armfuls running shot with goalkeeper. Maximal handgrip was also tested. Biacromial breadth shows a significative correlation with hand grip in water polo players (r=0.792; P=0.001) and also correlates with Throwing velocity (r=0.716; P<0.001). Biepicondylar femur breadth correlates significatively with hand grip (r=0.727; P<0.05) and also with throwing velocity in "throwing with goalkeeper" situation (r=0.664; P<0.05). Hand grip shows a significant correlation with throwing velocity in "throwing with goalkeeper" situation (r=0.603; P<0.05). In conclusion, body mass aspects are not related with throwing velocity in highly skilled Water Polo players. Maximal hand grip is related with throwing velocity in "throwing with goalkeeper" situation. More investigations about water polo are necessary.

  12. Finger pressure adjustments to various object configurations during precision grip in humans and monkeys.

    Science.gov (United States)

    Viaro, Riccardo; Tia, Banty; Coudé, Gino; Canto, Rosario; Oliynyk, Andriy; Salmas, Paola; Masia, Lorenzo; Sandini, Giulio; Fadiga, Luciano

    2017-06-01

    In this study, we recorded the pressure exerted onto an object by the index finger and the thumb of the preferred hand of 18 human subjects and either hand of two macaque monkeys during a precision grasping task. The to-be-grasped object was a custom-made device composed by two plates which could be variably oriented by a motorized system while keeping constant the size and thus grip dimension. The to-be-grasped plates were covered by an array of capacitive sensors to measure specific features of finger adaptation, namely pressure intensity and centroid location and displacement. Kinematic measurements demonstrated that for human subjects and for monkeys, different plate configurations did not affect wrist velocity and grip aperture during the reaching phase. Consistently, at the instant of fingers-plates contact, pressure centroids were clustered around the same point for all handle configurations. However, small pressure centroid displacements were specifically adopted for each configuration, indicating that both humans and monkeys can display finger adaptation during precision grip. Moreover, humans applied stronger thumb pressure intensity, performed less centroid displacement and required reduced adjustment time, as compared to monkeys. These pressure patterns remain similar when different load forces were required to pull the handle, as ascertained by additional measurements in humans. The present findings indicate that, although humans and monkeys share common features in motor control of grasping, they differ in the adjustment of fingertip pressure, probably because of skill and/or morphology divergences. Such a precision grip device may form the groundwork for future studies on prehension mechanisms. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  13. The bilateral movement condition facilitates maximal but not submaximal paretic-limb grip force in people with post-stroke hemiparesis

    Science.gov (United States)

    DeJong, Stacey L.; Lang, Catherine E.

    2012-01-01

    Objectives Although healthy individuals have less force production capacity during bilateral muscle contractions compared to unilateral efforts, emerging evidence suggests that certain aspects of paretic upper limb task performance after stroke may be enhanced by moving bilaterally instead of unilaterally. We investigated whether the bilateral movement condition affects grip force differently on the paretic side of people with post-stroke hemiparesis, compared to their non-paretic side and both sides of healthy young adults. Methods Within a single session, we compared: 1) maximal grip force during unilateral vs. bilateral contractions on each side, and 2) force contributed by each side during a 30% submaximal bilateral contraction. Results Healthy controls produced less grip force in the bilateral condition, regardless of side (- 2.4% difference), and similar findings were observed on the non-paretic side of people with hemiparesis (- 4.5% difference). On the paretic side, however, maximal grip force was increased by the bilateral condition in most participants (+11.3% difference, on average). During submaximal bilateral contractions in each group, the two sides each contributed the same percentage of unilateral maximal force. Conclusions The bilateral condition facilitates paretic limb grip force at maximal, but not submaximal levels. Significance In some people with post-stroke hemiparesis, the paretic limb may benefit from bilateral training with high force requirements. PMID:22248812

  14. Corticomuscular coherence during hand gripping with DBS and medication in PD patients

    DEFF Research Database (Denmark)

    Sridharan, Kousik Sarathy; Højlund, Andreas; Johnsen, Erik Lisbjerg

    Deep brain stimulation (DBS) effectively alleviates the motor symptoms in Parkinson’s disease (PD) although its effect mechanism is still unclear. CMC is reduced in PD patients but restorable with medication, while DBS variably affects CMC in advanced PD patients. We recorded magnetoencephalography...... (MEG) from six PD patients performing hand gripping during DBS ON and medicated (levodopa, MED ON) conditions and from ten age-matched healthy controls. Participants performed isotonic contractions (hand gripping) with their right hand, and electromyography (EMG) was recorded from the extensor...... digitorum communis muscle with a belly-tendon montage. We calculated the mean-squared coherence between MEG and the rectified EMG signals. For each group and condition, we selected the maximum CMC value in the beta range (13-30 Hz) within the average of an a priori selection of nine left sensorimotor...

  15. Eyes, Grip and Gesture as Objective Indicators of Intentions and Attention

    DEFF Research Database (Denmark)

    Mortensen, Ditte Hvas

    This poster abstract presents the first part of a study concerning the use of information about gaze, grip and gesture to create non-command interaction. The experiment reported here seeks to establish the occurrence of patterns in nonverbal communication,  which may be used in an activity aware...

  16. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  17. Effects of hyperthyroidism on hand grip strength and function

    OpenAIRE

    Esra Erkol İnal, MD; Alparslan Bayram Çarlı, MD; Sultan Çanak, MD; Oğuzhan Aksu, MD; Banu Kale Köroğlu, MD; Serpil Savaş

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism w...

  18. Fitts’ Law in the Control of Isometric Grip Force With Naturalistic Targets

    Directory of Open Access Journals (Sweden)

    Zachary C. Thumser

    2018-04-01

    Full Text Available Fitts’ law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts’ law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts’ law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task. Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task. Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback. This provided an opportunity to see if Fitts’ law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback. Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets to the more naturalistic and intuitive target forces implied by images of objects (implicit targets. With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts’ law (average r2 = 0.82. Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces

  19. Fitts' Law in the Control of Isometric Grip Force With Naturalistic Targets.

    Science.gov (United States)

    Thumser, Zachary C; Slifkin, Andrew B; Beckler, Dylan T; Marasco, Paul D

    2018-01-01

    Fitts' law models the relationship between amplitude, precision, and speed of rapid movements. It is widely used to quantify performance in pointing tasks, study human-computer interaction, and generally to understand perceptual-motor information processes, including research to model performance in isometric force production tasks. Applying Fitts' law to an isometric grip force task would allow for quantifying grasp performance in rehabilitative medicine and may aid research on prosthetic control and design. We examined whether Fitts' law would hold when participants attempted to accurately produce their intended force output while grasping a manipulandum when presented with images of various everyday objects (we termed this the implicit task). Although our main interest was the implicit task, to benchmark it and establish validity, we examined performance against a more standard visual feedback condition via a digital force-feedback meter on a video monitor (explicit task). Next, we progressed from visual force feedback with force meter targets to the same targets without visual force feedback (operating largely on feedforward control with tactile feedback). This provided an opportunity to see if Fitts' law would hold without vision, and allowed us to progress toward the more naturalistic implicit task (which does not include visual feedback). Finally, we changed the nature of the targets from requiring explicit force values presented as arrows on a force-feedback meter (explicit targets) to the more naturalistic and intuitive target forces implied by images of objects (implicit targets). With visual force feedback the relation between task difficulty and the time to produce the target grip force was predicted by Fitts' law (average r 2 = 0.82). Without vision, average grip force scaled accurately although force variability was insensitive to the target presented. In contrast, images of everyday objects generated more reliable grip forces without the visualized

  20. Applying support vector regression analysis on grip force level-related corticomuscular coherence

    DEFF Research Database (Denmark)

    Rong, Yao; Han, Xixuan; Hao, Dongmei

    2014-01-01

    Voluntary motor performance is the result of cortical commands driving muscle actions. Corticomuscular coherence can be used to examine the functional coupling or communication between human brain and muscles. To investigate the effects of grip force level on corticomuscular coherence in an acces...

  1. Comparison of Initial Effect of Taping Techniqe and Counterforce Brace on Pain and Grip Strength of Patients with Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Ali Reza Shamsoddini

    2006-04-01

    Full Text Available Objective: In patients with lateral epicondylitis present of pain and decrease of grip strength are essential problems. Use of splint have major rule in treatment these patients that causes relief of pain and increase of grip strength. Both taping technique and counterforce brace are two methods of treatments of lateral epicondylitis patients but we were not sure which method could be more useful and Answer of this question is magor aim of this study. Materials & Methods: This study is a Quasi experimental. We selected 30 patients between 30-55 years conveniently and divided them in two groups simple randomized.  Results: In grip strength test, the average difference between two methods was t = 1/92 which showed there is not significant. So, there isn't any difference between two methods on grip strength. In assessment of pain, we tested patients in two positions: first patient's hand was in comfort position, second in which when wrist of hand was in extension position. In both of position, that average difference between two methods (first t = 3/78 and secondary t = 3/2 found to be significant. Choose of method in such treatment is considered to be important. Conclusion: taping technique is more effective than counterforce brace to relief of pain of patients with lateral epicondylitis, but in grip strength no difference between two methods.

  2. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  3. The GRIP method for collaborative roadmapping workshops

    DEFF Research Database (Denmark)

    Piirainen, Kalle

    2015-01-01

    Technology roadmapping is a well-known tool for technology management, but practical advice for facilitating collaborative roadmapping workshops is relatively scarce. To cater for this need, we have designed a method for collaborative roadmapping, dubbed the GRIP method, for facilitating group work...... in TRM workshops. The design is based on establish best practices in facilitation and our experiences with the method suggest it is a feasible tool for technology managers. The benefits of the method are that it enables engaging a diverse group of individuals to the roadmapping process effectively even...... during a short workshop session and facilitates shared understanding on the technology management issues....

  4. A role of peripheral myelin protein 2 in lipid homeostasis of myelinating Schwann cells

    NARCIS (Netherlands)

    Zenker, J.; Stettner, M.; Ruskamo, S.; Domenech-Estevez, E.; Baloui, H.; Medard, J.J.; Verheijen, M.H.G.; Brouwers, J.F.; Kursula, P.; Kieseier, B.C.; Chrast, R.

    2014-01-01

    Peripheral myelin protein 2 (Pmp2, P2 or Fabp8), a member of the fatty acid binding protein family, was originally described together with myelin basic protein (Mbp or P1) and myelin protein zero (Mpz or P0) as one of the most abundant myelin proteins in the peripheral nervous system (PNS). Although

  5. A role of peripheral myelin protein 2 in lipid homeostasis of myelinating Schwann cells.

    NARCIS (Netherlands)

    Zenker, Jennifer; ruskamo, salla; domenech-estevez, Enric; medard, jean-jacques; Verheijen, M.H.; Brouwers, Jos|info:eu-repo/dai/nl/173812694; Kursula, Petri; kieseier, bernd; Chrast, Roman

    Peripheral myelin protein 2 (Pmp2, P2 or Fabp8), a member of the fatty acid binding protein family, was originally described together with myelin basic protein (Mbp or P1) and myelin protein zero (Mpz or P0) as one of the most abundant myelin proteins in the peripheral nervous system (PNS). Although

  6. Characterization of the spontaneous and gripping-induced immobility episodes on taiep rats.

    Science.gov (United States)

    Cortés, Ma Del Carmen; Gavito, Berenice; Ita, Martha L; Valencia, Jaime; Eguibar, José R

    2005-11-01

    In 1989, we described a new autosomic-recessive myelin-mutant rat that develops a progressive motor syndrome characterized by tremor, ataxia, immobility episodes (IEs), epilepsy, and paralysis. taiep is the acronym of these symptoms. The rat developed a hypomyelination, followed by demyelination. At an age of 7-8 months, taiep rats developed IEs, characterized electroencephalographically by REM sleep-like cortical activity. In our study, we analyzed the ontogeny of gripping-induced IEs between 5 and 18 months, their dependence to light-dark changes, sexual dimorphism, and susceptibility to mild stress. Our results showed that IEs start at an age of 6.5 months, with a peak frequency between 8.5 and 9.5 months. IEs have two peaks, one in the morning (0800-1000 h) and a second peak in the middle of the night (2300-0100 h). Spontaneous IEs showed an even distribution with a mean of 3 IEs every 2 h. IEs are sexually dimorphic being more common in male rats. The IEs can be induced by gripping the rat by the tail or the thorax, but most of the IEs were produced by gripping the tail. Mild stress produced by i.p. injection of physiological saline significantly decreased IEs. These results suggested that IEs are dependent on several biological variables, which are caused by hypomyelination, followed by demyelization, which causes alterations in the brainstem and hypothalamic mechanisms responsible for the sleep-wake cycle regulation, producing emergence of REM sleep-like behavior during awake periods. (c) 2005 Wiley-Liss, Inc.

  7. Association of the AMPA receptor-related postsynaptic density proteins GRIP and ABP with subsets of glutamate-sensitive neurons in the rat retina.

    Science.gov (United States)

    Gábriel, Robert; de Souza, Sunita; Ziff, Edward B; Witkovsky, Paul

    2002-07-22

    We used specific antibodies against two postsynaptic density proteins, GRIP (glutamate receptor interacting protein) and ABP (AMPA receptor-binding protein), to study their distribution in the rat retina. In the central nervous system, it has been shown that both proteins bind strongly to the AMPA glutamate receptor (GluR) 2/3 subunits, but not other GluRs, through a set of three PDZ domains. Western blots detected a single GRIP protein that was virtually identical in retina and brain, whereas retinal ABP corresponded to only one of three ABP peptides found in brain. The retinal distributions of GluR2/3, GRIP, and ABP immunoreactivity (IR) were similar but not identical. GluR2/3 immunoreactivity (IR) was abundant in both plexiform layers and in large perikarya. ABP IR was concentrated in large perikarya but was sparse in the plexiform layers, whereas GRIP IR was relatively more abundant in the plexiform layers than in perikarya. Immunolabel for these three antibodies consisted of puncta ABP IR was examined by double labeling subclasses of retinal neuron with characteristic marker proteins, e.g., calbindin. GRIP, ABP, and GluR2/3 IR were detected in horizontal cells, dopaminergic and glycinergic AII amacrine cells and large ganglion cells. Immunolabel was absent in rod bipolar and weak or absent in cholinergic amacrine cells. By using the tyramide method of signal amplification, a colocalization of GluR2/3 was found with either GRIP or ABP in horizontal cell terminals, and perikarya of amacrine and ganglion cells. Our results show that ABP and GRIP colocalize with GluR2/3 in particular subsets of retinal neuron, as was previously established for certain neurons in the brain. Copyright 2002 Wiley-Liss, Inc.

  8. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  9. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    International Nuclear Information System (INIS)

    Ismail, S S; Mohamad, M; Syazarina, S O; Nafisah, W Y

    2014-01-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain

  10. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    Science.gov (United States)

    Ismail, S. S.; Mohamad, M.; Syazarina, S. O.; Nafisah, W. Y.

    2014-11-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain.

  11. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    Science.gov (United States)

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  12. Electrical conductivity measurements from the GISP2 and GRIP Greenland ice cores

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Clausen, Henrik Brink; Taylor, K. C.

    1993-01-01

    . Here we present electrical conductivity records for the Greenland Ice Sheet Project 2 (GISP2) and Greenland Ice-core Project (GRIP) ice cores, drilled 28 km apart to enable direct comparison of the results. The upper parts of both records are consistent with previous evidence from other Greenland cores...

  13. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press

    Directory of Open Access Journals (Sweden)

    Lockie Robert G.

    2017-12-01

    Full Text Available The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM traditional bench press (TBP and close-grip bench press (CGBP. Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05 compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d were also calculated. Pearson’s correlations (r; p < 0.05 computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20. Peak power and velocity was greater for the CGBP (d = 0.50-1.29. The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982. TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931. TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704. TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980. Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  14. The Effect of Two Different Hand Exercises on Grip Strength, Forearm Circumference, and Vascular Maturation in Patients Who Underwent Arteriovenous Fistula Surgery

    Science.gov (United States)

    Kong, Sangwon; Lee, Kyung Soo; Kim, Junho

    2014-01-01

    Objective To compare the effect of two different hand exercises on hand strength and vascular maturation in patients who underwent arteriovenous fistula surgery. Methods We recruited 18 patients who had chronic kidney disease and had undergone arteriovenous fistula surgery for hemodialysis. After the surgery, 10 subjects performed hand-squeezing exercise with GD Grip, and other 8 subjects used Soft Ball. The subjects continued the exercises for 4 weeks. The hand grip strength, pinch strength (tip, palmar and lateral pinch), and forearm circumference of the subjects were assessed before and after the hand-squeezing exercise. The cephalic vein size, blood flow velocity and volume were also measured by ultrasonography in the operated limb. Results All of the 3 types of pinch strengths, grip strength, and forearm circumference were significantly increased in the group using GD Grip. Cephalic vein size and blood flow volume were also significantly increased. However, blood flow velocity showed no difference after the exercise. The group using Soft Ball showed a significant increase in the tip and lateral pinch strength and forearm circumference. The cephalic vein size and blood flow volume were also significantly increased. On comparing the effect of the two different hand exercises, hand-squeezing exercise with GD Grip had a significantly better effect on the tip and palmar pinch strength than hand-squeezing exercise with Soft Ball. The effect on cephalic vein size was not significantly different between the two groups. Conclusion The results showed that hand squeezing exercise with GD Grip was more effective in increasing the tip and palmar pinch strength compared to hand squeezing exercise with soft ball. PMID:25379494

  15. A COMPARATIVE STUDY TO FIND OUT IMMEDIATE EFFECTIVENESS OF MOVEMENT WITH MOBILIZATION VERSUS ELBOW ORTHOSIS ON PAIN AND GRIP STRENGTH IN LATERAL EPICONDYLITIS IN HOUSEWIVES

    Directory of Open Access Journals (Sweden)

    Trishna Kakati

    2015-12-01

    Full Text Available Background: There are various studies using Mulligan’s MWM with or without combining with electrotherapy modalities and proved the efficacy of the technique in immediately decreasing pain and improving grip strength in patients with lateral epicondylitis. Orthotic as a treatment is also proved to be beneficial in decreasing pain and improving grip strength. There is evidence that housewives are prone to develop lateral epicondylitis due to their routine household work. But there is lack of evidence which compare initial effects of MWM and orthosis in housewives bringing up better outcome measures. The purpose of this study is to compare the initial effectiveness of Mulligan’s MWM and elbow orthosis on pain and grip strength in housewives with lateral epicondylitis. The aim of the study is to evaluate the effectiveness of Mulligan’s MWM technique versus counterforce elbow orthosis in immediately reducing pain and improving grip strength in lateral epicondylitis in housewives. Methodos: All subjects underwent a pre-treatment examination to assess pain and pain free hand grip strength with the help of outcome measures. Subjects were randomly assigned into two groups, A and B respectively; having 25 subjects in each group. Group A was treated with one session of Mulligan’s MWM technique. Group B was treated with Counterforce elbow strap orthosis. Data was assessed pre-treatment and immediately after treatment. Visual Analogue Scale (VAS and hand grip on Hand Grip Dynamometer (HGD were used as outcome measures. Results: Independent t-test was performed to see the effectiveness between Mulligan’s MWM and elbow orthosis. For VAS, t = - 2.243 which is significant at 5% level of significance. It has been inferred that VAS decreases more when Mulligan’s MWM was applied. For HGD, t = 0.878 which is not significant implying that increase in HGD do not differ remarkably for the two treatments. Conclusion: It has been recorded from the study that

  16. The Effect of Isometric Massage on Global Grip Strength after Conservative Treatment of Distal Radial Fractures. Pilot Study.

    Science.gov (United States)

    Ratajczak, Karina; Płomiński, Janusz

    2015-01-01

    The most common fracture of the distal end of the radius is Colles' fracture. Treatment modalities available for use in hand rehabilitation after injury include massage. The aim of this study was to evaluate the effect of isometric massage on the recovery of hand function in patients with Colles fractures. For this purpose, the strength of the finger flexors was assessed as an objective criterion for the evaluation of hand function. The study involved 40 patients, randomly divided into Group A of 20 patients and Group B of 20 patients. All patients received physical therapy and exercised individually with a physiotherapist. Isometric massage was additionally used in Group A. Global grip strength was assessed using a pneumatic force meter on the first and last day of therapy. Statistical analysis was performed using STATISTICA. Statistical significance was defined as a P value of less than 0.05. In both groups, global grip strength increased significantly after the therapy. There was no statistically significant difference between the groups. The men and women in both groups equally improved grip strength. A statistically significant difference was demonstrated between younger and older patients, with younger patients achieving greater gains in global grip strength in both groups. The incorporation of isometric massage in the rehabilitation plan of patients after a distal radial fracture did not significantly contribute to faster recovery of hand function or improve their quality of life.

  17. Grip strength is strongly associated with height, weight and gender in childhood : a cross sectional study of 2241 children and adolescents providing reference values

    NARCIS (Netherlands)

    Ploegmakers, Joris J. W.; Hepping, Ann M.; Geertzen, Jan H. B.; Bulstra, Sjoerd K.; Stevens, Martin

    2013-01-01

    Question: What are reference values for grip strength in children and adolescents based on a large and heterogeneous study population? What is the association of grip strength with age, gender, weight, and height in this population? Design: Cross-sectional study. Participants: Participants were

  18. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  19. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Directory of Open Access Journals (Sweden)

    Suruchi Mishra

    Full Text Available Distributing daily protein intake evenly across meals (∼25-30g/meal has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults.Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123 who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively.Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (p<0.05 in unadjusted model, but not when adjusted. Grip strength was positively associated with daily protein intake among women in quartiles 3 and 4 (p<0.05 of protein intake in both unadjusted and adjusted models compared to lowest protein intake. Among men, grip strength was associated with daily protein intake in quartiles 3 and 4 (p<0.05 in the unadjusted model, but not when adjusted.In a nationally representative sample of older adults, consuming ≥25g

  20. A new classification for 'Pistol Grip Deformity'. Correlation between the severity of the deformity and the grade of osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ipach, Ingmar; Mittag, F.; Sachsenmaier, S.; Kluba, T.; Heinrich, P.

    2011-01-01

    Purpose: Two types of femoroacetabular impingement (FAI) are described as reasons for the early development of osteoarthritis of the hip. Cam impingement develops from contact between an abnormal head-neck junction and the acetabular rim. Pincer impingement is characterized by local or general overcoverage of the femoral head by the acetabular rim. Both forms might cause early osteoarthritis of the hip. A decreased head/neck offset has been recognized on AP pelvic views and labeled as 'pistol grip deformity'. The aim of the study was to develop a classification for this deformity with regard to the stage of osteoarthritis of the hip. Materials and Methods: 76 pelvic and axial views were analyzed for alpha angle and head ratio. 22 of them had a normal shape in the head-neck region and no osteoarthritis signs, 27 had a 'pistol grip deformity' and osteoarthritis I and 27 had a 'pistol grip deformity' and osteoarthritis II -IV . The CART method was used to develop a classification. Results: There was a statistically significant correlation between alpha angle and head ratio. A statistically significant difference in alpha angle and head ratio was seen between the three groups. Using the CART method, we developed a three-step classification system for the 'pistol grip deformity' with very high accuracy. This deformity was aggravated by increasing age. Conclusion: Using this model it is possible to differentiate between normal shapes of the head-neck junction and different severities of the pistol grip deformity. (orig.)

  1. Association between dietary protein intake and grip strength among adults aged 51 years and over: What We Eat in America, National Health and Nutrition Examination Survey 2011-2014.

    Science.gov (United States)

    Mishra, Suruchi; Goldman, Joseph D; Sahyoun, Nadine R; Moshfegh, Alanna J

    2018-01-01

    Distributing daily protein intake evenly across meals (∼25-30g/meal) has been suggested to improve muscle mass. The aim of this research is to examine the association between grip strength, total protein intake and its distribution across day's meals in older adults. Nationally representative dietary intake data of adults aged 51 years and older (n = 4,123) who participated in What We Eat in America, NHANES 2011-2014 were analyzed. Protein intake per day and per eating occasion (breakfast, lunch, dinner, and snack) were determined. Combined grip strength was calculated and expressed in kilograms. Grip strength of individuals consuming ≥25g protein at 1 eating occasion was compared with those consuming same level of protein at 2 and 3 or more eating occasions. Grip strength of individuals in quartile 1 of daily protein intake was compared to those in the other quartiles. All associations were examined without and with adjustment for age, race/ethnicity, physical activity, health status, and smoking status. The comparison involving eating occasions and protein intake quartiles were further adjusted for daily protein intake and energy intake, respectively. Only 33% of men and 19% of women had protein intake of ≥25g at 2 or more eating occasions. These individuals also had higher grip strength and daily protein intake. Grip strength was positively associated with consumption of ≥25g protein at 2 eating occasions as compared to consumption of same level of protein at 1 eating occasion (peating occasions was not associated with grip strength. However, higher daily protein intake was positively associated with grip strength in women.

  2. Grip strength in a cohort of older medical inpatients in Malaysia: a pilot study to describe the range, determinants and association with length of hospital stay.

    Science.gov (United States)

    Keevil, Victoria; Mazzuin Razali, Rizah; Chin, Ai-Vyrn; Jameson, Karen; Aihie Sayer, Avan; Roberts, Helen

    2013-01-01

    Grip strength is a marker of sarcopenia, the age-related decline in muscle mass and function, and has been little researched in Asian populations. We aimed to describe the feasibility and acceptability of measuring grip strength in hospitalized, older people in Malaysia and to explore its range, determinants and association with length of stay. Patients admitted acutely to the geriatrics ward of a teaching hospital were consecutively recruited. Inability to consent or use the dynamometer led to exclusion. Maximum grip strength, anthropometric data, length of hospital stay, discharge destination, 3-point Barthel score, mini-mental state examination, falls history and number of co-morbidities and medications on admission were recorded. 80/153 (52%) eligible patients were recruited (52 women; age range 64-100 years). 9/153 (6%) refused to participate and 64/153 (42%) were excluded (34 too unwell, 24 unable to consent, 4 unable to use the dynamometer, 2 other reasons). 76/80 patients (95%) reported that they would undergo grip strength measurement again. Determinants were similar to those of Caucasian populations but grip strength values were lower. After adjustment for sex, age and height, stronger grip strength was associated with shorter length of stay [hazard ratio 1.05 (95% CI 1.00, 1.09; P=0.03)]. This is the first report of grip strength measurement in hospitalized older people in Malaysia. It was feasible, acceptable to participants and associated with length of stay. Further research is warranted to elucidate the normative range in different ethnic groups and explore its potential use in clinical practice in Malaysia. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Study of the effects of the hand grip and finger strengths on the friction and petrissage - the massage manipulations - of the students who take massage courses: Kütahya City example

    Directory of Open Access Journals (Sweden)

    Erzeybek Mustafa Said

    2016-01-01

    Full Text Available In this research, the effect of the hand grip and finger strengths on the power development between the friction and petrissage techniques - the massage manipulations - have been studied. To the study that has been structured as a single group pretest/post test, 36 healthy males who are the students of the University of Dumlupınar, Academy of Physical Education and Sports and who take massage courses (age = 19.72 ± 1.56 years (average ± Sd have been included. The practical massage course has continued for 12 weeks, two days a week for a total of one hour and the hand grip strength of both hands (right hand grip strength = RHG, left hand grip strength = LHG and the grip strength of both fingers (right finger strength = RF, left finger strength = LF have been recorded at the beginning. For the measurements carried out before and later of the study with regard to the hand grip strength, a Takkei branded hand dynamometer and with regard to the finger grip strength a (baseline branded pinch meter have been used. All measurements have been repeated twice and for the analysis, the average values obtained from two deads have been used. For statistical analysis, with regard to the changes in the pre test-post test finger strength and hand grip strength, paired-samples t test has been used. The significance limit has been defined as p0.05. It is possible to report that massaging regularly with both hands is efficient for the development of the finger and hand grip strengths; especially, with regard to the friction (circular movements that are generally carried out with fingers and petrissage (kneading that is generally carried out with the palm techniques.

  4. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  5. Associations Between Diabetes and Both Cardiovascular Disease and All-Cause Mortality Are Modified by Grip Strength: Evidence From UK Biobank, a Prospective Population-Based Cohort Study.

    Science.gov (United States)

    Celis-Morales, Carlos A; Petermann, Fanny; Hui, Li; Lyall, Donald M; Iliodromiti, Stamatina; McLaren, James; Anderson, Jana; Welsh, Paul; Mackay, Daniel F; Pell, Jill P; Sattar, Naveed; Gill, Jason M R; Gray, Stuart R

    2017-12-01

    Grip strength and diabetes are predictors of mortality and cardiovascular disease (CVD), but whether these risk factors interact to predispose to adverse health outcomes is unknown. This study determined the interactions between diabetes and grip strength and their association with health outcomes. We undertook a prospective, general population cohort study by using UK Biobank. Cox proportional hazards models were used to explore the associations between both grip strength and diabetes and the outcomes of all-cause mortality and CVD incidence/mortality as well as to test for interactions between diabetes and grip strength. A total of 347,130 UK Biobank participants with full data available (mean age 55.9 years, BMI 27.2 kg/m 2 , 54.2% women) were included in the analysis, of which 13,373 (4.0%) had diabetes. Over a median follow-up of 4.9 years (range 3.3-7.8 years), 6,209 died (594 as a result of CVD), and 4,301 developed CVD. Participants with diabetes were at higher risk of all-cause and CVD mortality and CVD incidence. Significant interactions ( P strength. Similar results were observed for all-cause mortality and CVD incidence. Risk of adverse health outcomes among people with diabetes is lower in those with high grip strength. Low grip strength may be useful to identify a higher-risk subgroup of patients with diabetes. Intervention studies are required to determine whether resistance exercise can reduce risk. © 2017 by the American Diabetes Association.

  6. Constraints on grip selection in hemiparetic cerebral palsy: effects of lesional side, end-point accuracy, and context.

    Science.gov (United States)

    Steenbergen, Bert; Meulenbroek, Ruud G J; Rosenbaum, David A

    2004-04-01

    This study was concerned with selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment, we asked participants to pick up a pencil and place the tip in a pre-defined target region. We varied the size of the target to test the hypothesis that increased end-point precision demands would favour the use of a grip that affords end-state comfort. In the second experiment, we studied grip planning in three task contexts that were chosen to let us test the hypothesis that a more functional task context would likewise promote the end-state comfort effect. When movements were performed with the impaired hand, we found that participants with right hemiparesis (i.e., left brain damage) aimed for postural comfort at the start rather than at the end of the object-manipulation phase in both experiments. By contrast, participants with left hemiparesis (i.e., right brain damage) did not favour a particular selection criterion with the impaired hand in the first experiment, but aimed for postural comfort at the start in the second experiment. When movements were performed with the unimpaired hand, grip selection criteria again differed for right and left hemiparetic participants. Participants with right hemiparesis did not favour a particular selection criterion with the unimpaired hand in the first experiment and only showed the end-state comfort effect in the most functional tasks of the second experiment. By contrast, participants with left hemiparesis showed the end-state comfort effect in all conditions of both experiments. These data suggest that the left hemisphere plays a special role in action planning, as has been recognized before, and that one of the deficits accompanying left brain damage is a deficit in forward movement planning, which has not been recognized before. Our findings have both theoretical and clinical implications.

  7. Feeling is Believing: a location limited channel based on grip pattern biometrics and cryptanalysis

    NARCIS (Netherlands)

    Buhan, I.R.; Doumen, J.M.; Hartel, Pieter H.; Veldhuis, Raymond N.J.

    We use grip pattern based biometrics as a location limited channel to achieve pre-authentication in a protocol that sets up a secure cannel between two handheld devices. The protocol efficiently calculates a shared secret key from biometric data using quantization and cryptanalysis. The protocol is

  8. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  9. Television Viewing, Walking Speed, and Grip Strength in a Prospective Cohort Study

    Science.gov (United States)

    KEEVIL, VICTORIA L.; WIJNDAELE, KATRIEN; LUBEN, ROBERT; SAYER, AVAN A.; WAREHAM, NICHOLAS J.; KHAW, KAY-TEE

    2015-01-01

    ABSTRACT Purpose Television (TV) watching is the most prevalent sedentary leisure time activity in the United Kingdom. We examined associations between TV viewing time, measured over 10 yr, and two objective measures of physical capability, usual walking speed (UWS) and grip strength. Methods Community-based participants (n = 8623; 48–92 yr old) enrolled in the European Prospective Investigation of Cancer—Norfolk study attended a third health examination (3HC, 2006–2011) for measurement of maximum grip strength (Smedley dynamometer) and UWS. TV viewing time was estimated using a validated questionnaire (n = 6086) administered during two periods (3HC, 2006–2007; 2HC, 1998–2000). Associations between physical capability and TV viewing time category (<2, 2 < 3, 3 < 4, and ≥4 h·d−1) at the 3HC, 2HC, and using an average of the two measures were explored. Sex-stratified analyses were adjusted for age, physical activity, anthropometry, wealth, comorbidity, smoking, and alcohol intake and combined if no sex–TV viewing time interactions were identified. Results Men and women who watched the least TV at the 2HC or 3HC walked at a faster usual pace than those who watched the most TV. There was no evidence of effect modification by sex (Pinteraction = 0.09), and in combined analyses, participants who watched for <2 h·d−1 on average walked 4.29 cm·s−1 (95% confidence interval, 2.56–6.03) faster than those who watched for ≥4 h·d−1, with evidence of a dose–response association (Ptrend < 0.001). However, no strong associations with grip strength were found. Conclusions TV viewing time predicted UWS in older adults. More research is needed to inform public health policy and prospective associations between other measures of sedentariness, such as total sitting time or objectively measured sedentary time, and physical capability should be explored. PMID:25785826

  10. Anticipatory grip force between 1 and 3g

    Science.gov (United States)

    White, Olivier; Van Loon, ing.. Jack J. W. A.; Thonnard, Jean-Louis; Hermsdorfer, Joachim; Lefevre, Philippe

    One remarkable capacity of utilizing common tools appropriately as soon as we grasp them relies on the ability to determine in advance the grip force (GF) required to handle them in relation to their mechanical properties and the surrounding environment. This anticipatory strategy avoids the uncompressible delays in the feedback system. The predictive control of GF is made possible because the nervous system can learn, store and then select the internal representations of the dynamics of innumerable objects, known as internal models. Beside this flexibility, the nervous system's ability to learn different task dynamics is often limited in classical robotic experiments The environment itself can be profoundly modified in altered gravity or centrifugation. The few studies that investigated motor adaptation in such contexts did not consider the interaction between gravitational phases and even less the transitions across environments. Here, we tested subject's abilities to adapt to levels of gravitational fields generated by a human centrifuge. In Experiment 1, seven subjects performed 4 lifting trials in each gravitational phase (1 to 2.5g and then 2.5 to 1g by steps of 0.5g) with a 0.12 kg instrumented object. In Experiment 2, six subjects performed vertical oscillations of the object during transitions between 1 and 3g (0.5g steps, ascending and descending phases, profile repeated twice). We continuously measured GF, load force (LF) and ambient gravity. We hypothesized that participants were able to predictively adjust GF to the new environment. In Experiment 1, participants adjusted their GF proportionally to gravity and decreased GF across trials within a given gravitational environment. Preload phases decreased over time from 300ms to 50ms irrespective of gravity. We quantified the abilities of participants to switch across environments by subtracting GF recorded in the last trial in the current gravity level from GF during the first trial in the new environment

  11. Comparison of hand grip strength and upper limb pressure pain threshold between older adults with or without non-specific shoulder pain

    Directory of Open Access Journals (Sweden)

    Cesar Calvo Lobo

    2017-02-01

    Full Text Available Background There is a high prevalence of non-specific shoulder pain associated with upper limb functional limitations in older adults. The purpose of this study was to determine the minimal clinically important differences (MCID of grip strength and pressure pain threshold (PPT in the upper limb between older adults with or without non-specific shoulder pain. Methods A case-control study was carried out following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE criteria. A sample of 132 shoulders (mean ± SD years with (n = 66; 76.04 ± 7.58 and without (n = 66; 75.05 ± 6.26 non-specific pain were recruited. The grip strength and PPT of the anterior deltoid and extensor carpi radialis brevis (ECRB muscles were assessed. Results There were statistically significant differences (mean ± SD; P-value for anterior deltoid PPT (2.51 ± 0.69 vs 3.68 ± 0.65, kg/cm2; P < .001, ECRB PPT (2.20 ± 0.60 vs 3.35 ± 0.38 kg/cm2; P < .001 and grip strength (20.78 ± 10.94 vs 24.63 ± 9.38 kg; P = .032 between shoulders with and without non-specific pain, respectively. Discussion The MCID of 1.17 kg/cm2, 1.15 kg/cm2 and 3.84 kg were proposed for anterior deltoid PPT, ECRB PPT and grip strength, respectively, to assess the upper limb of older adults with non-specific shoulder pain after treatment. In addition, univariate and multivariate (linear regression and regression trees analyses may be used to consider age distribution, sex, pain intensity, grip strength and PPT in older adults including clinical and epidemiological studies with non-specific shoulder pain.

  12. Intraoperative monitoring technician: a new member of the surgical team.

    Science.gov (United States)

    Brown, Molly S; Brown, Debra S

    2011-02-01

    As surgery needs have increased, the traditional surgical team has expanded to include personnel from radiology and perfusion services. A new surgical team member, the intraoperative monitoring technician, is needed to perform intraoperative monitoring during procedures that carry a higher risk of central and peripheral nerve injury. Including the intraoperative monitoring technician on the surgical team can create challenges, including surgical delays and anesthesia care considerations. When the surgical team members, including the surgeon, anesthesia care provider, and circulating nurse, understand and facilitate this new staff member's responsibilities, the technician is able to perform monitoring functions that promote the smooth flow of the surgical procedure and positive patient outcomes. Copyright © 2011 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  13. Corrosion caused by elevator and spider marks on CRA pipe: Comparison of conventional inserts and a new gripping system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    Corrosion-resistant alloys (CRA) are used to reduce corrosion damage to casing and tubing strings and prolong the life span of the well pipe. An analysis of various corrosion mechanisms shows that surface integrity is an important factor in corrosion prevention. Surface damage caused by inappropriate handling or conventional slip markings contribute directly to the development and propagation of corrosion. A newly developed gripping system distributes the load equally onto a large number of small peaks, minimizing the indentation of each single peak. The new gripping system does not damage the surface integrity of the pipe, virtually eliminating the corrosion potential.

  14. Effect of skin hydration on the dynamics of fingertip gripping contact.

    Science.gov (United States)

    André, T; Lévesque, V; Hayward, V; Lefèvre, P; Thonnard, J-L

    2011-11-07

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction.

  15. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n3p292   The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  16. On being peripheral: Effects of identity insecurity on personal and collective self-esteem

    NARCIS (Netherlands)

    Jetten, J.; Branscombe, N.R.; Spears, R.

    2002-01-01

    We examined collective self-esteem and personal self-esteem as a function of anticipated changes in one's prototypicality within a valued ingroup. In Study 1 (N = 80), all participants received information that they were currently peripheral group members. Expectations for the future were then

  17. On being peripheral : effects of identity insecurity on personal and collective self-esteem

    NARCIS (Netherlands)

    Jetten, J; Branscombe, NR; Spears, R

    2002-01-01

    We examined collective self-esteem and personal self-esteem as a function of anticipated changes in one's prototypicality, within a valued ingroup. In Study, 1 (N=80), all participants received information that they, it-ere currently peripheral group members. Expectations for the future were then

  18. Evidence of central and peripheral vestibular pathology in blast-related traumatic brain injury.

    Science.gov (United States)

    Scherer, Matthew R; Burrows, Holly; Pinto, Robin; Littlefield, Philip; French, Louis M; Tarbett, Aaron K; Schubert, Michael C

    2011-06-01

    To prospectively assay the vestibular and oculomotor systems of blast-exposed service members with traumatic brain injury (TBI). Prospective, nonblinded, nonrandomized descriptive study. Tertiary care facility (Department of Defense Medical Center). Twenty-four service members recovering from blast-related TBI sustained in Iraq or Afghanistan. Focused history and physical, videonystagmography (VNG), rotational chair, cervical vestibular-evoked myogenic potentials, computerized dynamic posturography, and self-report measures. Vestibular testing confirms a greater incidence of vestibular and oculomotor dysfunction in symptomatic (vestibular-like dizziness) personnel with blast-related TBI relative to asymptomatic group members. VNG in the symptomatic group revealed abnormal nystagmus or oculomotor findings in 6 of 12 subjects tested. Similarly, rotational chair testing in this group revealed evidence of both peripheral (4/12) and central (2/12) vestibular pathology. By contrast, the asymptomatic group revealed less vestibular impairment with 1 of 10 rotational chair abnormalities. The asymptomatic group was further characterized by fewer aberrant nystagmus findings (4/12 abnormal VNGs). Computerized dynamic posturography testing revealed no significant differences between groups. Self-report measures demonstrated differences between groups. Vestibular function testing confirms a greater incidence of peripheral vestibular hypofunction in dizzy service members with blast-related TBI relative to those who are asymptomatic. Additionally, oculomotor abnormalities and/or nystagmus consistent with central involvement were present in 10 of the 24 study participants tested. The precise cause of these findings remains unknown.

  19. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  20. The SAO and Kelvin waves in the EuroGRIPS GCMS and the UK Met. Office analyses

    Directory of Open Access Journals (Sweden)

    M. Amodei

    2001-01-01

    Full Text Available We compare the tropical oscillations and planetary scale Kelvin waves in four troposphere-stratosphere climate models and the assimilated dataset produced by the United Kingdom Meteorological Office (UKMO. The comparison has been made in the GRIPS framework "GCM-Reality Intercomparison Project for SPARC", where SPARC is Stratospheric Processes and their Role in Climate, a project of the World Climate Research Program. The four models evaluated are European members of GRIPS: the UKMO Unified Model (UM, the model of the Free University in Berlin (FUB–GCM, the ARPEGE-climat model of the French National Centre for Meteorological Research (CNRM, and the Extended UGAMP GCM (EUGCM of the Centre for Global Atmospheric Modelling (CGAM. The integrations were performed with different, but annually periodic external conditions (e.g., sea-surface temperature, sea ice, and incoming solar radiation. The structure of the tropical winds and the strengths of the Kelvin waves are examined. In the analyses where the SAO (Semi-Annual Oscillation and the QBO (Quasi-Biennal Oscillation are reasonably well captured, the amplitude of these analysed Kelvin waves is close to that observed in independent data from UARS (Upper Atmosphere Research Satellite. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets, consistent with a convective forcing origin. In three of the models, slow Kelvin waves propagate too high and their amplitudes are overestimated in the upper stratosphere and in the mesosphere, the exception is the UM which has weaker waves. None of the modelled waves are sufficient to force realistic eastward phases of the QBO or SAO. Although the SAO is represented by all models, only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played in the SAO by unresolved gravity waves is emphasized. Although it exhibits some unrealistic features, the

  1. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Science.gov (United States)

    Papiorek, Sarah; Junker, Robert R; Lunau, Klaus

    2014-01-01

    Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of flower-visitors.

  2. Gloss, colour and grip: multifunctional epidermal cell shapes in bee- and bird-pollinated flowers.

    Directory of Open Access Journals (Sweden)

    Sarah Papiorek

    Full Text Available Flowers bear the function of filters supporting the attraction of pollinators as well as the deterrence of floral antagonists. The effect of epidermal cell shape on the visual display and tactile properties of flowers has been evaluated only recently. In this study we quantitatively measured epidermal cell shape, gloss and spectral reflectance of flowers pollinated by either bees or birds testing three hypotheses: The first two hypotheses imply that bee-pollinated flowers might benefit from rough surfaces on visually-active parts produced by conical epidermal cells, as they may enhance the colour signal of flowers as well as the grip on flowers for bees. In contrast, bird-pollinated flowers might benefit from flat surfaces produced by flat epidermal cells, by avoiding frequent visitation from non-pollinating bees due to a reduced colour signal, as birds do not rely on specific colour parameters while foraging. Moreover, flat petal surfaces in bird-pollinated flowers may hamper grip for bees that do not touch anthers and stigmas while consuming nectar and thus, are considered as nectar thieves. Beside this, the third hypothesis implies that those flower parts which are vulnerable to nectar robbing of bee- as well as bird-pollinated flowers benefit from flat epidermal cells, hampering grip for nectar robbing bees. Our comparative data show in fact that conical epidermal cells are restricted to visually-active parts of bee-pollinated flowers, whereas robbing-sensitive parts of bee-pollinated as well as the entire floral surface of bird-pollinated flowers possess on average flat epidermal cells. However, direct correlations between epidermal cell shape and colour parameters have not been found. Our results together with published experimental studies show that epidermal cell shape as a largely neglected flower trait might act as an important feature in pollinator attraction and avoidance of antagonists, and thus may contribute to the partitioning of

  3. Tyre-road grip coefficient assessment - Part II: online estimation using instrumented vehicle, extended Kalman filter, and neural network

    Science.gov (United States)

    Luque, Pablo; Mántaras, Daniel A.; Fidalgo, Eloy; Álvarez, Javier; Riva, Paolo; Girón, Pablo; Compadre, Diego; Ferran, Jordi

    2013-12-01

    The main objective of this work is to determine the limit of safe driving conditions by identifying the maximal friction coefficient in a real vehicle. The study will focus on finding a method to determine this limit before reaching the skid, which is valuable information in the context of traffic safety. Since it is not possible to measure the friction coefficient directly, it will be estimated using the appropriate tools in order to get the most accurate information. A real vehicle is instrumented to collect information of general kinematics and steering tie-rod forces. A real-time algorithm is developed to estimate forces and aligning torque in the tyres using an extended Kalman filter and neural networks techniques. The methodology is based on determining the aligning torque; this variable allows evaluation of the behaviour of the tyre. It transmits interesting information from the tyre-road contact and can be used to predict the maximal tyre grip and safety margin. The maximal grip coefficient is estimated according to a knowledge base, extracted from computer simulation of a high detailed three-dimensional model, using Adams® software. The proposed methodology is validated and applied to real driving conditions, in which maximal grip and safety margin are properly estimated.

  4. Bilateral deficits in fine motor control and pinch grip force are not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    Science.gov (United States)

    de la Llave-Rincón, Ana Isabel; Fernández-de-Las-Peñas, César; Pérez-de-Heredia-Torres, Marta; Martínez-Perez, Almudena; Valenza, Marie Carmen; Pareja, Juan A

    2011-06-01

    : The aim of this study was to analyze the differences in deficits in fine motor control and pinch grip force between patients with minimal, moderate/mild, or severe carpal tunnel syndrome (CTS) and healthy age- and hand dominance-matched controls. : A case-control study was conducted. The subtests of the Purdue Pegboard Test (one-hand and bilateral pin placements and assemblies) and pinch grip force between the thumb and the remaining four fingers of the hand were bilaterally evaluated in 66 women with minimal (n = 16), moderate (n = 16), or severe (n = 34) CTS and in 20 age- and hand-matched healthy women. The differences among the groups were analyzed using different mixed models of analysis of variance. : A two-way mixed analysis of variance revealed significant differences between groups, not depending on the presence of unilateral or bilateral symptoms (side), for the one-hand pin placement subtest: patients showed bilateral lower scores compared with controls (P < 0.001), without differences among those with minimal, moderate, or severe CTS (P = 0.946). The patients also exhibited lower scores in bilateral pin placement (P < 0.001) and assembly (P < 0.001) subtests, without differences among them. The three-way analysis of variance revealed significant differences among groups (P < 0.001) and fingers (P < 0.001), not depending on the presence of unilateral/bilateral symptoms (P = 0.684), for pinch grip force: patients showed bilateral lower pinch grip force in all fingers compared with healthy controls, without differences among those with minimal, moderate, or severe CTS. : The current study revealed similar bilateral deficits in fine motor control and pinch grip force in patients with minimal, moderate, or severe CTS, supporting that fine motor control deficits are a common feature of CTS not associated with electrodiagnostic findings.

  5. Hand grip strength in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Jeong M

    2017-08-01

    Full Text Available Moa Jeong,1 Hyung Koo Kang,1 Pamela Song,2 Hye Kyeong Park,1 Hoon Jung,1 Sung-Soon Lee,1 Hyeon-Kyoung Koo1 1Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 2Department of Neurology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea Purpose: Hand grip strength (HGS is a simple way of predicting the risk of cardiovascular disease and all-cause mortality in the general population. However, the practical significance of grip strength in patients with COPD is uncertain. The aim of this study was to compare HGS between subjects with and without COPD and to evaluate its clinical relevance in patients with COPD by using a national survey.Methods: Data were collected from the Korean National Health and Nutrition Examination Survey. The study included 421 adults with COPD and 2,542 controls who completed questionnaires, spirometry, and a HGS test. HGS was compared between subjects with and without COPD, and the association between grip strength, lung function, and quality of life (QoL was evaluated.Results: The mean HGS was 33.3±9.1 kg in the COPD group and 29.9±9.5 kg in the non-COPD group; adjusted HGS was 30.9±0.33 kg and 30.9±0.11 kg, respectively (P=0.99. HGS was not related to forced vital capacity (β=0.04, P=0.70 or forced expiratory volume in 1 second (β=0.11, P=0.24 in multivariable analysis. HGS was independently associated with the EQ-5D index, but the relationship was stronger in the COPD group (β=0.30, P<0.001 than in the non-COPD group (β=0.21, P<0.001. The results were similar for each component of the EQ-5D, including mobility (β=-0.25, P<0.001, daily activity (β=-0.19, P=0.01, pain/discomfort (β=-0.32, P<0.001, and anxiety/depression (β=-0.16, P=0.01.Conclusion: HGS was not different between subjects with and without COPD, but was associated with QoL – including mobility, daily activity, pain/discomfort, and anxiety/depression – in patients with COPD. The

  6. The predictive value of the extensor grip test for the effectiveness of bracing for tennis elbow

    NARCIS (Netherlands)

    Struijs, Peter A. A.; Assendelft, Willem J. J.; Kerkhoffs, Gino M. M. J.; Souer, Sebastiaan; van Dijk, C. Niek

    2005-01-01

    Background: Tennis elbow is a common complaint. Several treatment strategies, such as corticosteroid injections and physical therapy and braces, have been described. Hypothesis: The extensor grip test has predictive value in assessing the effectiveness of bracing in tennis elbow. Study Design:

  7. Grip-Pattern Verification for Smart Gun Based on Maximum-Pairwise Comparison and Mean-Template Comparison

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.

    2008-01-01

    In our biometric verification system of a smart gun, the rightful user of a gun is authenticated by grip-pattern recognition. In this work verification will be done using two types of comparison methods, respectively. One is mean-template comparison, where the matching score between a test image and

  8. Association between grip strength and diabetes prevalence in black, South-Asian, and white European ethnic groups: a cross-sectional analysis of 418 656 participants in the UK Biobank study.

    Science.gov (United States)

    Ntuk, U E; Celis-Morales, C A; Mackay, D F; Sattar, N; Pell, J P; Gill, J M R

    2017-08-01

    To quantify the extent to which ethnic differences in muscular strength might account for the substantially higher prevalence of diabetes in black and South-Asian compared with white European adults. This cross-sectional study used baseline data from the UK Biobank study on 418 656 white European, black and South-Asian participants, aged 40-69 years, who had complete data on diabetes status and hand-grip strength. Associations between hand-grip strength and diabetes were assessed using logistic regression and were adjusted for potential confounding factors. Lower grip strength was associated with higher prevalence of diabetes, independent of confounding factors, across all ethnicities in both men and women. Diabetes prevalence was approximately three- to fourfold higher in South-Asian and two- to threefold higher in black participants compared with white European participants across all levels of grip strength, but grip strength in South-Asian men and women was ~ 5-6 kg lower than in the other ethnic groups. Thus, the attributable risk for diabetes associated with low grip strength was substantially higher in South-Asian participants (3.9 and 4.2 cases per 100 men and women, respectively) than in white participants (2.0 and 0.6 cases per 100 men and women, respectively). Attributable risk associated with low grip strength was also high in black men (4.3 cases) but not in black women (0.4 cases). Low strength is associated with a disproportionately large number of diabetes cases in South-Asian men and women and in black men. Trials are needed to determine whether interventions to improve strength in these groups could help reduce ethnic inequalities in diabetes prevalence. © 2017 Diabetes UK.

  9. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Directory of Open Access Journals (Sweden)

    Hannes Höppner

    2017-05-01

    Full Text Available We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands.

  10. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    Science.gov (United States)

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Development of force sensing circuit to determine the optimal force required for effective dynamic tripod grip/writing

    Science.gov (United States)

    Suraj S., S.; Kulkarni, Palash; Bokadia, Pratik; Ramanathan, Prabhu; Nageswaran, Sharmila

    2018-04-01

    Handwriting is a combination of fine motor perceptions and cognitive skills to produce words on paper. For writing, the most commonly used and recommended grip is the dynamic tripod grip. A child's handwriting starts developing during the times of pre-schooling and improves over time. While writing, children apply excessive force on the writing instrument. This force is exerted by their fingers and as per the law of reaction, the writing instruments tend to exert an equal and opposite force, that could damage the delicate soft tissue structures in their fingers and initiate cramps and pains. This condition is also prevalent in adults who tend to write for long hours under pressure. An example would be adolescence student during the exams. Clinically this condition is termed as `Writer's Cramp', which is usually characterized by muscle fatigue and pain in the fingers. By understanding and fixing the threshold of the force that should be exerted by the fingers while gripping the instrument, the pain can be controlled or avoided. This research aims in designing an electronic module which can help in understanding the threshold of pressure which is optimum enough to establish a better contact between the fingers and the instrument and should be capable of controlling or avoiding the pain. The design of FSR based electronic system is explained with its circuitry and results of initial testing is presented in this paper.

  13. The Effects of Counterforce Brace Size on the Wrist Range of Motility, Pain, Grip & Wrist Extension Sterngth in Normal Subjects and Patients with Tennis Elbow

    Directory of Open Access Journals (Sweden)

    Ali Asghar Jameh-Bozorgi

    2006-04-01

    Full Text Available Objective: Counter force brace is one of the most usefull treatments for lateral opicondylitis (Tennis elbow because it decreases grip pain and increases the power of grip, power of wrist extension and Wrist Range of Motility. The purpose of this quasi experimental (repeated measurementsstudy was to determine the effect of 3 counterforce brace sizes on the wrist R.O.M, grip and wrist extension strength and pain intensity in two groups of healthy subjects and patients with tennis elbow. Materials & Methods: 18 normal subjects & 18 patients with tennis elbow were selected simple conveniently and were tested with no brace and 3 size of counterforce (1,2 and 3 inches. The R.O.M , strength and pain intensity were measured by jamar goniometry and Nicholas MMT dynamometry & VAS, respectively. Results: 1 With all sizes there was a significant decrease of R.O.M on normal subjects but no significant difference in patients. 2 There was a significant decrease of grip strength with 1-inch brace in normal subjects but a significant increase of grip strength with 2 and 3-inch brace in patiens. 3 All sizes of brace caused significant decrease of extension strength in normal subjects but increase in patients. 4All size caused significant decrease of pain intensity that was more considerable in the case of 2 and 3 inch size. Conclusion: The results shows that the counterforce brace may be considered as an effective treatment for increasing strength and decreasing pain in patients with tennis elbow.

  14. Peripheral Androgen Receptor Gene Suppression Rescues Disease in Mouse Models of Spinal and Bulbar Muscular Atrophy

    Directory of Open Access Journals (Sweden)

    Andrew P. Lieberman

    2014-05-01

    Full Text Available Spinal and bulbar muscular atrophy (SBMA is caused by the polyglutamine androgen receptor (polyQ-AR, a protein expressed by both lower motor neurons and skeletal muscle. Although viewed as a motor neuronopathy, data from patients and mouse models suggest that muscle contributes to disease pathogenesis. Here, we tested this hypothesis using AR113Q knockin and human bacterial artificial chromosome/clone (BAC transgenic mice that express the full-length polyQ-AR and display androgen-dependent weakness, muscle atrophy, and early death. We developed antisense oligonucleotides that suppressed AR gene expression in the periphery but not the CNS after subcutaneous administration. Suppression of polyQ-AR in the periphery rescued deficits in muscle weight, fiber size, and grip strength, reversed changes in muscle gene expression, and extended the lifespan of mutant males. We conclude that polyQ-AR expression in the periphery is an important contributor to pathology in SBMA mice and that peripheral administration of therapeutics should be explored for SBMA patients.

  15. Sex Differences in the Level and Rate of Change of Physical Function and Grip Strength in the Danish 1905-Cohort Study

    DEFF Research Database (Denmark)

    Oksuzyan, Anna; Maier, Heiner; McGue, Matt

    2010-01-01

    OBJECTIVE: The study was conducted to examine sex differences in the initial level and rate of change in physical function and grip strength. METHOD: The baseline survey included 2,262 Danes born in 1905 and alive in 1998 and followed-up in 2000, 2003, and 2005. Hence, the authors fully used...... the power of having a cohort with multiple assessments in late life and virtually complete follow-up of lifespan (through December 2008). Latent growth curve modeling was used. RESULTS: Men had higher initial levels and rates of decline in strength score and grip strength. Lifespan was positively correlated...

  16. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  17. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  18. The role of left supplementary motor area in grip force scaling.

    Directory of Open Access Journals (Sweden)

    Olivier White

    Full Text Available Skilled tool use and object manipulation critically relies on the ability to scale anticipatorily the grip force (GF in relation to object dynamics. This predictive behaviour entails that the nervous system is able to store, and then select, the appropriate internal representation of common object dynamics, allowing GF to be applied in parallel with the arm motor commands. Although psychophysical studies have provided strong evidence supporting the existence of internal representations of object dynamics, known as "internal models", their neural correlates are still debated. Because functional neuroimaging studies have repeatedly designated the supplementary motor area (SMA as a possible candidate involved in internal model implementation, we used repetitive transcranial magnetic stimulation (rTMS to interfere with the normal functioning of left or right SMA in healthy participants performing a grip-lift task with either hand. TMS applied over the left, but not right, SMA yielded an increase in both GF and GF rate, irrespective of the hand used to perform the task, and only when TMS was delivered 130-180 ms before the fingers contacted the object. We also found that both left and right SMA rTMS led to a decrease in preload phase durations for contralateral hand movements. The present study suggests that left SMA is a crucial node in the network processing the internal representation of object dynamics although further experiments are required to rule out that TMS does not affect the GF gain. The present finding also further substantiates the left hemisphere dominance in scaling GF.

  19. Grip strength measurements at two different wrist extension positions in chronic lateral epicondylitis-comparison of involved vs. uninvolved side in athletes and non athletes: a case-control study

    Directory of Open Access Journals (Sweden)

    Bhargava Arti S

    2010-09-01

    Full Text Available Abstract Background Lateral epicondylitis is a common sports injury of the elbow caused due to altered muscle activation during repetitive wrist extension in many athletic and non-athletic endeavours. The amount of muscle activity and timing of contraction eventually is directly dependent upon joint position during the activity. The purpose of our study was to compare the grip strength in athletes with lateral epicondylalgia in two different wrist extension positions and compare them between involved and uninvolved sides of athletes and non-athletes. Methods An assessor-blinded case-control study of eight athletes and twenty-two non-athletes was done. The grip strength was measured using JAMAR® hand dynamometer in kilograms-force at 15 degrees (slightly extended and 35 degrees (moderately extended wrist extension positions (maintained by wrist splints on both involved and uninvolved sides of athletes and non-athletes with unilateral lateral epicondylitis of atleast 3 months duration. Their pain was to be elicited with local tenderness and two of three tests being positive- Cozen's, Mill's manoeuvre, resisted middle finger extension tests. For comparisons of grip strength, Wilcoxon signed rank test was used for within-group comparison (between 15 and 35 degrees wrist extension positions and Mann-Whitney U test was used for between-group (athletes vs. non-athletes comparisons at 95% confidence interval and were done using SPSS 11.5 for Windows. Results Statistically significant greater grip strength was found in 15 degrees (27.75 ± 4.2 kgms in athletes; 16.45 ± 4.2 kgms in non-athletes wrist extension than at 35 degrees (25.25 ± 3.53 kgm in athletes and 14.18 ± 3.53 kgm in non-athletes. The athletes had greater grip strength than non-athletes in each of test positions (11.3 kgm at 15 degrees and 11.07 kgm at 35 degrees measured. There was also a significant difference between involved and uninvolved sides' grip strength at both wrist

  20. Effort, performance, and motivation: insights from robot-assisted training of human golf putting and rat grip strength.

    Science.gov (United States)

    Duarte, Jaime E; Gebrekristos, Berkenesh; Perez, Sergi; Rowe, Justin B; Sharp, Kelli; Reinkensmeyer, David J

    2013-06-01

    Robotic devices can modulate success rates and required effort levels during motor training, but it is unclear how this affects performance gains and motivation. Here we present results from training unimpaired humans in a virtual golf-putting task, and training spinal cord injured (SCI) rats in a grip strength task using robotically modulated success rates and effort levels. Robotic assistance in golf practice increased trainees feelings of competence, and, paradoxically, increased their sense effort, even though it had mixed effects on learning. Reducing effort during a grip strength training task led rats with SCI to practice the task more frequently. However, the more frequent practice of these rats did not cause them to exceed the strength gains achieved by rats that exercised less often at higher required effort levels. These results show that increasing success and decreasing effort with robots increases motivation, but has mixed effects on performance gains.

  1. alpha2 adrenoceptors are involved in the regulation of the gripping-induced immobility episodes in taiep rats.

    Science.gov (United States)

    Eguibar, José R; Cortés, Ma Del Carmen; Valencia, Jaime; Arias-Montaño, José A

    2006-10-01

    In 1989 Holmgren et al. (Holmgren et al. 1989 Lab Anim Sci 39:226-228) described a new mutant rat that developed a progressive motor disturbance during its lifespan. The syndrome is characterized by a tremor in the hind limbs followed by ataxia, episodes of tonic immobility, epilepsy, and paralysis. The acronym of these symptoms (taiep) became the name of this autosomic, recessive mutant rat. The taiep rats are neurological mutant animals with a hypomyelination, followed by a progressive demyelination process. At 7-8 months of age, taiep rats develop immobility episodes (IEs) characterized by a cortical desynchronization, associated with the theta rhythm in the hippocampus and changes of the nucal electromyogram (EMG), whose pattern is like rapid-eye-movement (REM) sleep. These rats also show an altered sleep pattern with an equal REM sleep distribution. This study analyzed therole of alpha(2) adrenoceptors in the expression of gripping-induced IEs in 8-month-old male taiep rats. The alpha(2) adrenoceptor agonists clonidine and xylacine increased the frequency of gripping-induced IEs whereas the alpha(2) antagonists yohimbine and idazoxandecreased or prevented such episodes. These findings correlate with the pharmacological observations in narcoleptic dogs and humans in which alpha(2) adrenergic mechanisms are involved in the modulation of cataplexy. Unexpectedly, the repetitive administration of clonidine resulted in jumping behavior, indicative of phasic activation of extensor musculature. Taken together, our results show that alpha(2) adrenoceptors are involved in the modulation in gripping-induced IEs and after the administration of several doses of clonidine produced phasic motor activation.

  2. Coefficient of friction of dry slash pine and southern red oak on three tension-grip facings

    Science.gov (United States)

    Truett J. Lemoine; Peter Koch

    1974-01-01

    A urethane material proved to have nine times higher static friction coefficient (0.9) than smooth steel (0.1) on radial and tangential wood surfaces pulled parallel to the grain. It is probably superior to 220-grit garnet paper or sand coatings for tension-grip facings in lumber testing machines.

  3. NBL Pistol Grip Tool for Underwater Training of Astronauts

    Science.gov (United States)

    Liszka, Michael; Ashmore, Matthew; Behnke, Mark; Smith, Walter; Waterman, Tod

    2011-01-01

    A document discusses a lightweight, functional mockup of the Pistol Grip Tool for use during underwater astronaut training. Previous training tools have caused shoulder injuries. This new version is more than 50 percent lighter [in water, weight is 2.4 lb (=1.1 kg)], and can operate for a six-hour training session after 30 minutes of prep for submersion. Innovations in the design include the use of lightweight materials (aluminum and Delrin(Registered TradeMark)), creating a thinner housing, and the optimization of internal space with the removal of as much excess material as possible. This reduces tool weight and maximizes buoyancy. Another innovation for this tool is the application of a vacuum that seats the Orings in place and has shown to be reliable in allowing underwater usage for up to six hours.

  4. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  5. Wheelchair Mobility Performance enhancement by Changing Wheelchair Properties; What is the Effect of Grip, Seat Height and Mass?

    Science.gov (United States)

    van der Slikke, Rienk M A; de Witte, Annemarie M H; Berger, Monique A M; Bregman, Daan J J; Veeger, Dirk Jan H E J

    2018-02-12

    The purpose of this study was to provide insight in the effect of wheelchair settings on wheelchair mobility performance. Twenty elite wheelchair basketball athletes of low (n=10) and high classification (n=10), were tested in a wheelchair basketball directed field test. Athletes performed the test in their own wheelchair, which was modified for five additional conditions regarding seat height (high - low), mass (central - distributed) and grip. The previously developed, inertial sensor based wheelchair mobility performance monitor 1 was used to extract wheelchair kinematics in all conditions. Adding mass showed most effect on wheelchair mobility performance, with a reduced average acceleration across all activities. Once distributed, additional mass also reduced maximal rotational speed and rotational acceleration. Elevating seat height had effect on several performance aspects in sprinting and turning, whereas lowering seat height influenced performance minimally. Increased rim grip did not alter performance. No differences in response were evident between low and high classified athletes. The wheelchair mobility performance monitor showed sensitive to detect performance differences due to the small changes in wheelchair configuration made. Distributed additional mass had the most effect on wheelchair mobility performance, whereas additional grip had the least effect of conditions tested. Performance effects appear similar for both low and high classified athletes. Athletes, coaches and wheelchair experts are provided with insight in the performance effect of key wheelchair settings, and they are offered a proven sensitive method to apply in sports practice, in their search for the best wheelchair-athlete combination.

  6. Limited Investigation of the Effects of Elevator Rate Limiting and Stick Dynamics on Longitudinal Pilot Induced Oscillations (HAVE GRIP)

    National Research Council Canada - National Science Library

    Peters, Patrick

    1996-01-01

    This report presents the results of the HAVE GRIP flight test program. This program performed a limited investigation of the effects of stick dynamics and elevator rate limiting on longitudinal pilot induced oscillations (PIOs...

  7. Fuel assembly gripping device using self-locking mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs.

  8. Fuel assembly gripping device using self-locking mechanism

    International Nuclear Information System (INIS)

    Lee, G. M.; Choi, S.; Kim, K. S.; Kim, T. W.; Jeong, K. H.; Park, K. B.; Chang, M. H.

    1999-07-01

    This report presents an actuating principles and structure for two kind of the fuel assembly gripping devices (Gripper-A, B) developed for SMART. The main components of these grippers are push bundle, rotation bundle, upper guide tube and chuck assembly. The rope attached to winch system on moving cask hangs gripper's push bundle. Due to a down-and-up operation of winch system, the push bundle pushes crown teeth shaped rotation bundle and then it is pushed down and rotated counter clockwise. The push-and-pull sequential operation of push bundle makes the rotation bundle is pushed, rotated and returned, moreover it makes the chuck assembly is expanded or shrunk. The expansion and shrinkage motion of chuck assembly makes the gripper latch and release the fuel assembly. Gripper-A suits for the handling of the fuel assembly with square shaped latching hole. Otherwise Gripper-B suits for a circular shaped latching hole. (author). 5 refs., 20 figs

  9. Vitamin D status predicts hand-grip strength in young adult women living in Auckland, New Zealand.

    Science.gov (United States)

    von Hurst, P R; Conlon, C; Foskett, A

    2013-07-01

    The identification of the vitamin D receptor (VDR) in skeletal muscle tissue and research in muscle strength and development in VDR-null mice confirms a role for vitamin D in muscle function. The relationship between muscle strength and vitamin D status has been explored to some degree in older populations with regard to fall prevention, but there has been very little research in younger adults. This cross-sectional study considered the predictors of muscle strength in 137 young women (19-29 years) living in New Zealand. The following measurements were taken in the latter months of winter: plasma 25OHD, dominant (HGD) and non-dominant hand-grip (HGND) strength (hand-grip dynamometer), counter measure jump, and recreational physical activity (RPA) assessed from a recent physical activity questionnaire (RPAQ). Dietary intake was measured with a four-day food diary, and body composition using air displacement plethysmography. This was a relatively inactive group of women; total RPA ranged from 0 to 3.93h per week, mean (SD) 0.86(0.74) h, approximately 50% comprised outdoor activities. Mean 25OHD was 54(28)nmol/l, HGD and HGND were significantly different (t=6.049, pstrength as the dependent variable (Model R(2)=0.11, p=0.001 non-dominant, R(2)=0.13, pstrength and serum 25OHD, and when each were adjusted to remove this association, 25OHD accounted for 4.3% of HGND and 4.5% of HGD. These results suggest that vitamin D status does have a small but significant association with hand-grip strength in this group of young women. Further investigation in this age group with a randomised controlled trial is justified. This article is part of a Special Issue entitled 'Vitamin D Workshop'. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  11. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment

    Science.gov (United States)

    White, Olivier

    2015-01-01

    In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force (GF), normal to the finger/object contact, in anticipation of the expected tangential load force (LF), resulting from the combination of the gravitational and the inertial forces. In many contexts, GF and LF are linearly coupled. A few studies have examined how we adjust the parameters–gain and offset–of this linear relationship. However, the question remains open as to how the brain adjusts GF regardless of whether LF is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of LF by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust GF, the brain is sensitive to how LFs are produced at the fingertips. This provides clear evidence that the analysis of the origin of LF is performed centrally, and not only at the periphery. PMID:25717293

  12. Efeito da preensão manual sobre o equilíbrio de judocas Effect of hand grip on the balance of judokas

    Directory of Open Access Journals (Sweden)

    Jonathan Ache Dias

    2011-06-01

    Full Text Available O objetivo deste estudo foi verificar se existe efeito da preensão manual máxima (o ato de realizar ou não a preensão sobre o controle do equilíbrio de judocas em postura restrita, além de verificar se existe correlação entre a força de preensão manual (FPM e o controle do equilíbrio. Foram avaliados sete judocas com um dinamômetro e uma plataforma estabilométrica sendo mensuradas, concomitantemente, a FPM e o centro de pressão (CP. Foi verificado que até 80% da variabilidade do CP pode ser atrelada a preensão manual indicando que a mesma gera perturbações no controle do equilíbrio. Entretanto, foram encontradas correlações (r = 0,348 até 0,816 entre a FPM e o deslocamento do CP. Com isso pode-se concluir que, apesar da preensão manual gerar perturbações no equilíbrio, seu comportamento parece estar relacionado com os movimentos do corpo realizados para manter o equilíbrio, indicando uma possível correlação entre esses fenômenos.The purpose of this study was to verify if there is an effect of maximum hand grip (the act of performing or not the hand grip on the balance control of judokas in a restrict posture, and also to verify if there is a correlation between the hand grip strength (HGS and the balance control. Seven judokas were evaluated with a dynamometer and a stabilometric force platform, being measured, at the same time, the HGS and the center of pressure (COP. It was found that up to 80% of the COP variability was related to the hand grip demonstrating that it generates perturbations to the balance control. However, It was found correlations (r = 0,348 to 0,816 between de HGS and de COP displacement. With that, it can be concluded that, despite the hand grip generating perturbation on the balance, its behavior appears to be related to the body movements performed to sustain balance, indicating a possible correlation between this phenomenons.

  13. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  14. Short-Term Effects of Whole-Body Vibration Combined with Task-Related Training on Upper Extremity Function, Spasticity, and Grip Strength in Subjects with Poststroke Hemiplegia: A Pilot Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Jung-Sun; Kim, Chang-Yong; Kim, Hyeong-Dong

    2016-08-01

    The aim of this study was to determine the effect of whole-body vibration training combined with task-related training on arm function, spasticity, and grip strength in subjects with poststroke hemiplegia. Forty-five subjects with poststroke were randomly allocated to 3 groups, each with 15 subjects as follows: control group, whole-body vibration group, and whole-body vibration plus task-related training group. Outcome was evaluated by clinical evaluation and measurements of the grip strength before and 4 weeks after intervention. Our results show that there was a significantly greater increase in the Fugl-Meyer scale, maximal grip strength of the affected hand, and grip strength normalized to the less affected hand in subjects undergoing the whole-body vibration training compared with the control group after the test. Furthermore, there was a significantly greater increase in the Wolf motor function test and a decrease in the modified Ashworth spasticity total scores in subjects who underwent whole-body vibration plus task-related training compared with those in the other 2 groups after the test. The findings indicate that the use of whole-body vibration training combined with task-related training has more benefits on the improvement of arm function, spasticity, and maximal grip strength than conventional upper limb training alone or with whole-body vibration in people with poststroke hemiplegia.

  15. Influence of the gripping fixture on the modified compact tension test results: Evaluation of the experiments on cylindrical concrete specimens

    Czech Academy of Sciences Publication Activity Database

    Holušová, T.; Lozano, M.; Canteli, A.; Komárková, T.; Kocáb, D.; Seitl, Stanislav

    2015-01-01

    Roč. 15, č. 2 (2015) ISSN 1804-4824 Institutional support: RVO:68081723 Keywords : Modified compact tension test * fracture parametr * Cementitious composites * Aramis measurement * grips Subject RIV: JL - Materials Fatigue, Friction Mechanics

  16. Device for refueling a nuclear reactor having a core comprising a plurality of fuel assemblies

    International Nuclear Information System (INIS)

    Van Santen, A.; Elofsson, K.

    1975-01-01

    A nuclear reactor formed of fuel assemblies each including a plurality of parallel fuel rods arranged in a predetermined fuel rod lattice, which rods are freely extractable and insertable at one end of the fuel assembly, is refueled by extracting from one of the fuel assemblies a number of fuel rods substantially less than the total number of fuel rods and replacing these by inserting new fuel rods into the vacated positions. The removal and return of the rods is produced by a tool having a plurality of gripping members capable of engaging shoulders beneath heads formed on the upper ends of the fuel rods. This may be accomplished by providing a tool having a number of gripping members attached to the tool body corresponding to the lattice positions of the fuel rods to be extracted, having gripping members which can be pushed together to grip beneath shoulders on the upper ends of the fuel rods. (Official Gazette)

  17. Constraints on grip selection in hemiparetic cerebral palsy: Effects of lesional side, end-point accuracy and context.

    NARCIS (Netherlands)

    Steenbergen, B.; Meulenbroek, R.G.J.; Rosenbaum, D.A.

    2004-01-01

    This study was concerned with the selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment participants picked up a pencil and placed the tip in a pre-defined target region. We varied the size of the target to test the hypothesis

  18. EyeGrip: Detecting Targets in a Series of Uni-directional Moving Objects Using Optokinetic Nystagmus Eye Movements

    DEFF Research Database (Denmark)

    Jalaliniya, Shahram; Mardanbeigi, Diako

    2016-01-01

    computers. In this paper, we demonstrate the rich capabilities of EyeGrip with two example applications: 1) a mind reading game, and 2) a picture selection system. Our study shows that by selecting an appropriate speed and maximum number of visible images in the screen the proposed method can be used...

  19. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  20. A firm political grip on the market

    International Nuclear Information System (INIS)

    Bakken, Stein Arne

    2003-01-01

    In Norway, there is a strong political grip on the energy supply industry. The market is going to play a marginal role. The article deals with three scenarios for what the Norwegian energy supply might look like in 2005 as envisaged by a group of researchers in a comprehensive project carried out by ECON. The first scenario, ''The Market Place'', shows the development of the energy supply from regulation to a free market in the wake of the new Energy Act. According to this scenario, by 2005 the market should be well established as a form of control. The second scenario, ''The Norwegian Way'', shows the way of the energy supply from a free market to regulation. The third scenario is ''The Field of Force'' and shows how the energy supply develops into a strong energy industrial complex; this is the scenario that definitely has not come true. The most likely scenario to come true in ten years is probably a mixture of ''The Market Place'' and ''The Norwegian Way'' with an emphasis on the latter. The trend is clearly for increased political control

  1. Performance of repetitive tasks induces decreased grip strength and increased fibrogenic proteins in skeletal muscle: role of force and inflammation.

    Directory of Open Access Journals (Sweden)

    Samir M Abdelmagid

    Full Text Available This study elucidates exposure-response relationships between performance of repetitive tasks, grip strength declines, and fibrogenic-related protein changes in muscles, and their link to inflammation. Specifically, we examined forearm flexor digitorum muscles for changes in connective tissue growth factor (CTGF; a matrix protein associated with fibrosis, collagen type I (Col1; a matrix component, and transforming growth factor beta 1 (TGFB1; an upstream modulator of CTGF and collagen, in rats performing one of two repetitive tasks, with or without anti-inflammatory drugs.To examine the roles of force versus repetition, rats performed either a high repetition negligible force food retrieval task (HRNF, or a high repetition high force handle-pulling task (HRHF, for up to 9 weeks, with results compared to trained only (TR-NF or TR-HF and normal control rats. Grip strength declined with both tasks, with the greatest declines in 9-week HRHF rats. Quantitative PCR (qPCR analyses of HRNF muscles showed increased expression of Col1 in weeks 3-9, and CTGF in weeks 6 and 9. Immunohistochemistry confirmed PCR results, and also showed greater increases of CTGF and collagen matrix in 9-week HRHF rats than 9-week HRNF rats. ELISA, and immunohistochemistry revealed greater increases of TGFB1 in TR-HF and 6-week HRHF, compared to 6-week HRNF rats. To examine the role of inflammation, results from 6-week HRHF rats were compared to rats receiving ibuprofen or anti-TNF-α treatment in HRHF weeks 4-6. Both treatments attenuated HRHF-induced increases in CTGF and fibrosis by 6 weeks of task performance. Ibuprofen attenuated TGFB1 increases and grip strength declines, matching our prior results with anti-TNFα.Performance of highly repetitive tasks was associated with force-dependent declines in grip strength and increased fibrogenic-related proteins in flexor digitorum muscles. These changes were attenuated, at least short-term, by anti-inflammatory treatments.

  2. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  3. Changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis caused by frequency of physical therapy: a randomized controlled trial.

    Science.gov (United States)

    Lee, Soyoung; Ko, Youngjun; Lee, Wanhee

    2014-07-01

    [Purpose] The purpose of this study was to investigate the changes in pain, dysfunction, and grip strength of patients with acute lateral epicondylitis and to suggest the appropriate treatment frequency and period. [Subjects] The subjects were divided into three: 2 days per week group (n=12), 3 days per week group (n=15), and 6 days per week group (n=13). [Methods] All groups received conventional physical therapy for 40 minutes and therapeutic exercises for 20 minutes per session during 6 weeks. The outcome measurements were the visual analogue scale (VAS), Patient-Rated Tennis Elbow Evaluation (PRTEE), and grip strength. [Results] The results of this study were as follows: at 3 weeks, there were no significant differences in VAS and PRTEE in the 3 groups, but at 6 weeks, 6 days per week group significantly decreased these two outcomes. Grip strength was significantly increased in 3 and 6 days per week groups at 6 weeks. [Conclusion] In conclusion, physical therapy is needed 3 days per week for 3 weeks in patients with acute lateral epicondylitis. After 3 weeks, 6 days per week is the most effective treatment frequency.

  4. Laterality and grip strength influence hand bone micro-architecture in modern humans, an HRpQCT study.

    Science.gov (United States)

    Reina, Nicolas; Cavaignac, Etienne; Trousdale, William H; Laffosse, Jean-Michel; Braga, José

    2017-06-01

    It is widely hypothesized that mechanical loading, specifically repetitive low-intensity tasks, influences the inner structure of cancellous bone. As such, there is likely a relationship between handedness and bone morphology. The aim of this study is to determine patterns in trabecular bone between dominant and non-dominant hands in modern humans. Seventeen healthy patients between 22 and 32 years old were included in the study. Radial carpal bones (lunate, capitate, scaphoid, trapezium, trapezoid, 1st, 2nd and 3rd metacarpals) were analyzed with high-resolution micro-computed tomography. Additionally, crush and pinch grip were recorded. Factorial analysis indicated that bone volume ratio, trabeculae number (Tb.N), bone surface to volume ratio (BS.BV), body weight, stature and crush grip were all positively correlated with principal components 1 and 2 explaining 78.7% of the variance. Volumetric and trabecular endostructural parameters (BV/TV, BS/BV or Tb.Th, Tb.N) explain the observed inter-individual variability better than anthropometric or clinical parameters. Factors analysis regressions showed correlations between these parameters and the dominant side for crush strength for the lunate (r 2 = 0.640, P modern human wrist. © 2017 Anatomical Society.

  5. Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces.

    Science.gov (United States)

    Micera, Silvestro; Rossini, Paolo M; Rigosa, Jacopo; Citi, Luca; Carpaneto, Jacopo; Raspopovic, Stanisa; Tombini, Mario; Cipriani, Christian; Assenza, Giovanni; Carrozza, Maria C; Hoffmann, Klaus-Peter; Yoshida, Ken; Navarro, Xavier; Dario, Paolo

    2011-09-05

    The restoration of complex hand functions by creating a novel bidirectional link between the nervous system and a dexterous hand prosthesis is currently pursued by several research groups. This connection must be fast, intuitive, with a high success rate and quite natural to allow an effective bidirectional flow of information between the user's nervous system and the smart artificial device. This goal can be achieved with several approaches and among them, the use of implantable interfaces connected with the peripheral nervous system, namely intrafascicular electrodes, is considered particularly interesting. Thin-film longitudinal intra-fascicular electrodes were implanted in the median and ulnar nerves of an amputee's stump during a four-week trial. The possibility of decoding motor commands suitable to control a dexterous hand prosthesis was investigated for the first time in this research field by implementing a spike sorting and classification algorithm. The results showed that motor information (e.g., grip types and single finger movements) could be extracted with classification accuracy around 85% (for three classes plus rest) and that the user could improve his ability to govern motor commands over time as shown by the improved discrimination ability of our classification algorithm. These results open up new and promising possibilities for the development of a neuro-controlled hand prosthesis.

  6. The Effect of Repetitive Rhythmic Precision Grip Task-Oriented Rehabilitation in Chronic Stroke Patients: A Pilot Study

    Science.gov (United States)

    Dispa, Delphine; Lejeune, Thierry; Thonnard, Jean-Louis

    2013-01-01

    Most chronic stroke patients present with difficulty in the manipulation of objects. The aim of this study was to test whether an intensive program of precision grip training could improve hand functioning of patients at more than 6 months after a stroke. This was a cross-over study; hence, at inclusion, the patients were randomly divided into two…

  7. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  8. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  9. Weight-specific anticipatory coding of grip force in human dorsal premotor cortex

    DEFF Research Database (Denmark)

    van Nuenen, Bart F L; Kuhtz-Buschbeck, Johann; Schulz, Christian

    2012-01-01

    , using either continuous theta burst stimulation (cTBS) at 80% (inhibitory cTBS) or 30% (sham cTBS) of active motor threshold. The conditioning effects of cTBS on preparatory brain activity were assessed with functional MRI, while participants lifted a light or heavy weight in response to a go-cue (S2......). An additional pre-cue (S1) correctly predicted the weight in 75% of the trials. Participants were asked to use this prior information to prepare for the lift. In the sham condition, grip force showed a consistent undershoot, if the S1 incorrectly prompted the preparation of a light lift. Likewise, an S1...... during object lifting....

  10. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  11. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  12. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  13. Synchronising EDML and NorthGRIP ice cores using d18O of atmospheric oxygen (d18 Oatm) and CH4 measurements over MIS5 (80-123 kyr)

    DEFF Research Database (Denmark)

    Capron, E; Landais, A; Lemieux-Dudon, B

    2010-01-01

    Water isotope records from the EPICA Dronning Maud Land (EDML) and the NorthGRIP ice cores have revealed a one to one coupling between Antarctic Isotope Maxima (AIM) and Greenland Dansgaard-Oeschger (DO) events back to 50 kyr. In order to explore if this north-south coupling is persistent over...... Marine Isotopic Stage 5 (MIS 5). a common timescale must first be constructed. Here, we present new records of delta O-18 of O-2 (delta O-18(atm)) and methane (CH4) measured in the air trapped in ice from the EDML (68-147 kyr) and NorthGRIP (70-123 kyr) ice cores. We demonstrate that, through the period...... of interest, CH4 records alone are not sufficient to construct a common gas timescale between the two cores. Millennial-scale variations of delta O-18(atm) are evidenced over MIS 5 both on the Antarctic and Greenland ice cores and are coupled to CH4 profiles to synchronise the NorthGRIP and EDML records...

  14. Real time relationship between individual finger force and grip exertion on distal phalanges in linear force following tasks.

    Science.gov (United States)

    Luo, Shi-Jian; Shu, Ge; Gong, Yan

    2018-05-01

    Individual finger force (FF) in a grip task is a vital concern in rehabilitation engineering and precise control of manipulators because disorders in any of the fingers will affect the stability or accuracy of the grip force (GF). To understand the functions of each finger in a dynamic grip exertion task, a GF following experiment with four individual fingers without thumb was designed. This study obtained four individual FFs from the distal phalanges with a cylindrical handle in dynamic GF following tasks. Ten healthy male subjects with similar hand sizes participated in the four-finger linear GF following tasks at different submaximal voluntary contraction (SMVC) levels. The total GF, individual FF, finger force contribution, and following error were subsequently calculated and analyzed. The statistics indicated the following: 1) the accuracy and stability of GF at low %MVC were significantly higher than those at high SMVC; 2) at low SMVC, the ability of the fingers to increase the GF was better than the ability to reduce it, but it was contrary at high SMVC; 3) when the target wave (TW) was changing, all four fingers strongly participated in the force exertion, but the participation of the little finger decreased significantly when TW remained stable; 4) the index finger and ring finger had a complementary relationship and played a vital role in the adjustment and control of GF. The middle finger and little finger had a minor influence on the force control and adjustment. In conclusion, each of the fingers had different functions in a GF following task. These findings can be used in the assessment of finger injury rehabilitation and for algorithms of precise control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Imaginary Pasts: Colonisation, Migration and Loss in J.G. Farrell’s 'The Singapore Grip' and in Amitav Ghosh’s 'The Glass Palace'

    Directory of Open Access Journals (Sweden)

    Michael C. Prusse

    2009-11-01

    Full Text Available A quotation from each of the two novels that form the background for this paper will immediately establish why these narratives are pertinent to the central theme of the ‘Moving Cultures, Shifting Identities Conference’ that took place at Flinders University in Adelaide early in December 2007. In both texts the theme of migration in the context of imperialism plays a central role and, moreover, both clearly spell out what tremendous impact moving between and across cultures has on the lives of people, who are thoroughly affected and marked by such encounters. Matthew Webb, one of the protagonists of J.G. Farrell’s The Singapore Grip (1978, renders his perception of the phenomenon of migration in the wake of imperial expansion as follows: ‘One of the most astounding things about our Empire … is the way we’ve transported vast populations across the globe as cheap labour’. Matthew, a critical observer of British imperialism but still a member of colonial society and a British citizen, thus provides the reader with an insight regarding the economic motivation behind such enforced movements of people.

  16. Grounding by Attention Simulation in Peripersonal Space: Pupils Dilate to Pinch Grip But Not Big Size Nominal Classifier.

    Science.gov (United States)

    Lobben, Marit; Bochynska, Agata

    2018-03-01

    Grammatical categories represent implicit knowledge, and it is not known if such abstract linguistic knowledge can be continuously grounded in real-life experiences, nor is it known what types of mental states can be simulated. A former study showed that attention bias in peripersonal space (PPS) affects reaction times in grammatical congruency judgments of nominal classifiers, suggesting that simulated semantics may include reenactment of attention. In this study, we contrasted a Chinese nominal classifier used with nouns denoting pinch grip objects with a classifier for nouns with big object referents in a pupil dilation experiment. Twenty Chinese native speakers read grammatical and ungrammatical classifier-noun combinations and made grammaticality judgment while their pupillary responses were measured. It was found that their pupils dilated significantly more to the pinch grip classifier than to the big object classifier, indicating attention simulation in PPS. Pupil dilations were also significantly larger with congruent trials on the whole than in incongruent trials, but crucially, congruency and classifier semantics were independent of each other. No such effects were found in controls. Copyright © 2017 Cognitive Science Society, Inc.

  17. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  18. New results on the relation between tyre-road longitudinal stiffness and maximum available grip for motor car

    Science.gov (United States)

    Andrieux, A.; Vandanjon, P. O.; Lengelle, R.; Chabanon, C.

    2010-12-01

    Tyre-road estimation methods have been the objective of many research programmes throughout the world. Most of these methods aim at estimating the friction components such as tyre longitudinal slip rate κ and friction coefficient μ in the contact patch area. In order to estimate the maximum available friction coefficient μmax, these methods generally use a probabilistic relationship between the grip obtained for low tyre excitations (such as constant speed driving) and the grip obtained for high tyre excitations (such as emergency braking manoeuvre). Confirmation or invalidation of this relationship from experimental results is the purpose of this paper. Experiments have been carried out on a reference track including several test boards corresponding to a wide textural spectrum. The main advantage of these experiments lies in the use of a vehicle allowing us to accurately build point-by-point relationship between κ and μ. This relationship has been determined for different tyres and pavement textures. Finally, the curves obtained are analysed to check the validity of the relationship between the current friction coefficient used by the car during normal driving conditions and μmax.

  19. Installation of dynamic travel time signs and efforts to obtain and test a graphical route information panel (GRIP) sign in Austin.

    Science.gov (United States)

    2016-08-01

    Graphic Route Information Panel (GRIP) signs use a combination of text, colors, and representative maps of : the roadway system to convey real-time roadway congestion location and severity information. The intent of : this project was to facilitate t...

  20. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis

    DEFF Research Database (Denmark)

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I

    2014-01-01

    OBJECTIVE: We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). METHODS: PubMed and Embase databases were searched up to June 2013. We selected studies assessing...

  1. The Effect of Dry Needling of the Trigger Points of Shoulder Muscles on Pain and Grip Strength in Patients with Lateral Epicondylitis: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Alireza Kheradmandi

    2015-09-01

    Full Text Available Background: Lateral epicondylitis, also known as tennis elbow, is the most common overuse syndrome of the elbow. The severity of pain may not be directly caused by tendinopathy of wrist extensors since trigger points of the shoulder muscles have a referral zone in the arm and elbow. Therefore the aim of this study was to evaluate the effect of dry needling of shoulder myofascial trigger points on wrist extensors muscles pain and function. Methods: Fourteen female patients with tennis elbow (aged 20 - 45 years old were recruited after primary evaluation by an orthopedist. They entered the study if they had pain in the lateral aspect of elbow of the dominant hand for more than 3 months along with the presence of myofascial trigger points in any muscles of supra spinatus, infra spinatus, sub scapularis or scalenes. Pain pressure threshold, maximal grip force and pain intensity of the hand extensors on lateral epicondyle of elbow were measured before and after treatment. Pain intensity was measured on a one to ten scale of visual analogue scale (VAS. A hand dynamometer used to measure the maximal grip force value of the affected hand in 0˚shoulder flexion/ abduction, 90˚ elbow extension and mid-poison of forearm in sitting position. A pressure algometer was applied on hand extensor muscles to define their trigger point sensitivity. For the control group, treatment regimens consisted of routine physical therapy of tennis elbow. This regime was accompanied by dry needling of mentioned muscles for the intervention group. Wilcoxon and Mann-Whitney non-parametric tests were used for statistical analysis. Results: Comparison of the results after intervention showed that the patients’ pain significantly decreased in both groups (P<0.001; but the patient’s PPT and grip force significantly increased solely in the intervention group (P<0.05. Mann Whitney test showed significant pain differences in both groups (P=0.001. The comparison of differences

  2. Normative data for hand grip strength and key pinch strength, stratified by age and gender for a multiethnic Asian population.

    Science.gov (United States)

    Lam, Ngee Wei; Goh, Hui Ting; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Poi, Philip Jun Hua; Tan, Maw Pin

    2016-10-01

    Hand strength is a good indicator of physical fitness and frailty among the elderly. However, there are no published hand strength references for Malaysians aged > 65 years. This study aimed to establish normative data for hand grip strength (HGS) and key pinch strength (KPS) for Malaysians aged ≥ 60 years, and explore the relationship between hand strength and physical ability. Healthy participants aged ≥ 60 years with no neurological conditions were recruited from rural and urban locations in Malaysia. HGS and KPS were measured using hand grip and key pinch dynamometers. Basic demographic data, anthropometric measures, modified Barthel Index scores and results of the Functional Reach Test (FRT), Timed Up and Go (TUG) test and Jebsen-Taylor Hand Function Test (JTHFT) were recorded. 362 subjects aged 60-93 years were recruited. The men were significantly stronger than the women in both HGS and KPS (p Malaysia. Future studies are required to determine the modifiable factors for poor hand strength. Copyright: © Singapore Medical Association

  3. Penstemon lanceolatus Benth. or P. ramosus Crosswhite in Arizona and New Mexico, a peripheral or endemic species?

    Science.gov (United States)

    J. L. Anderson; S. Richmond-Williams; O. Williams

    2007-01-01

    The red-flowered member of Penstemon sect. Chamaeleon from southeastern Arizona and southwestern New Mexico has been treated taxonomically both as part of the Mexican species, P. lanceolatus Benth., and as a separate species, P. ramosus Crosswhite. Under the former treatment the Arizona and New Mexico populations are peripheral populations of a primarily Mexican...

  4. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  5. Ataxia and peripheral nerve hypomyelination in ADAM22-deficient mice

    Directory of Open Access Journals (Sweden)

    Ino Mitsuhiro

    2005-05-01

    Full Text Available Abstract Background ADAM22 is a member of the ADAM gene family, but the fact that it is expressed only in the nervous systems makes it unique. ADAM22's sequence similarity to other ADAMs suggests it to be an integrin binder and thus to have a role in cell-cell or cell-matrix interactions. To elucidate the physiological functions of ADAM22, we employed gene targeting to generate ADAM22 knockout mice. Results ADAM22-deficient mice were produced in a good accordance with the Mendelian ratio and appeared normal at birth. After one week, severe ataxia was observed, and all homozygotes died before weaning, probably due to convulsions. No major histological abnormalities were detected in the cerebral cortex or cerebellum of the homozygous mutants; however, marked hypomyelination of the peripheral nerves was observed. Conclusion The results of our study demonstrate that ADAM22 is closely involved in the correct functioning of the nervous system. Further analysis of ADAM22 will provide clues to understanding the mechanisms of human diseases such as epileptic seizures and peripheral neuropathy.

  6. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  7. Analysis of the effects of hospitalization on fine hand functions compared to gross grip in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Zeynep Tuna

    2015-09-01

    Full Text Available Objective: Hospitalization process causes a variety of physical problems. The decrease of hand use in daily life during hospitalization brings hand dysfunction to mind in inpatients. The aim of this study is to compare the hand functions of hospitalized patients with Rheumatoid Arthritis (RA to outpatients in detail. Methods: Grip and pinch strengths of both hospitalized patients in rheumatology service and outpatients on the routine control day were measured. In addition, 9-Hole Peg Test was performed and the disability level was determined by the Turkish version of Michigan Hand Outcomes Questionnaire (MHOQ. Results: While grip strength and MHOQ scores were similar (p>0.05 in both groups, all three pinch strengths (lateral, bipod, tripod and 9HPT scores were lower (p<0.05 in hospitalized patients. Conclusion: Consequently, besides disease activity, hospitalization process also impairs fine hand functions in rheumatological patients. Evaluation of fine hand functions and appropriate rehabilitative interventions may prevent further disability in hospitalized patients. J Clin Exp Invest 2015; 6 (3: 228-232

  8. Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces

    Directory of Open Access Journals (Sweden)

    Cipriani Christian

    2011-09-01

    Full Text Available Abstract Background The restoration of complex hand functions by creating a novel bidirectional link between the nervous system and a dexterous hand prosthesis is currently pursued by several research groups. This connection must be fast, intuitive, with a high success rate and quite natural to allow an effective bidirectional flow of information between the user's nervous system and the smart artificial device. This goal can be achieved with several approaches and among them, the use of implantable interfaces connected with the peripheral nervous system, namely intrafascicular electrodes, is considered particularly interesting. Methods Thin-film longitudinal intra-fascicular electrodes were implanted in the median and ulnar nerves of an amputee's stump during a four-week trial. The possibility of decoding motor commands suitable to control a dexterous hand prosthesis was investigated for the first time in this research field by implementing a spike sorting and classification algorithm. Results The results showed that motor information (e.g., grip types and single finger movements could be extracted with classification accuracy around 85% (for three classes plus rest and that the user could improve his ability to govern motor commands over time as shown by the improved discrimination ability of our classification algorithm. Conclusions These results open up new and promising possibilities for the development of a neuro-controlled hand prosthesis.

  9. The Effect of Hand Dimensions, Hand Shape and Some Anthropometric Characteristics on Handgrip Strength in Male Grip Athletes and Non-Athletes

    Science.gov (United States)

    Fallahi, Ali Asghar; Jadidian, Ali Akbar

    2011-01-01

    It has been suggested that athletes with longer fingers and larger hand surfaces enjoy stronger grip power. Therefore, some researchers have examined a number of factors and anthropometric variables that explain this issue. To our knowledge, the data is scarce. Thus, the aim of this study was to investigate the effect of hand dimensions, hand shape and some anthropometric characteristics on handgrip strength in male grip athletes and non-athletes. 80 subjects aged between 19 and 29 participated in this study in two groups including: national and collegian grip athletes (n=40), and non-athletes (n=40). Body height and mass were measured to calculate body mass index. The shape of the dominant hand was drawn on a piece of paper with a thin marker so that finger spans, finger lengths, and perimeters of the hand could be measured. The hand shape was estimated as the ratio of the hand width to hand length. Handgrip strength was measured in the dominant and non-dominant hand using a standard dynamometer. Descriptive statistics were used for each variable and independent t test was used to analyze the differences between the two groups. The Pearson correlation coefficient test was used to evaluate the correlation between studied variables. Also, to predict important variables in handgrip strength, the linear trend was assessed using a linear regression analysis. There was a significant difference between the two groups in absolute handgrip strength (p0.05) were significantly different between the groups (ptalent identification in handgrip-related sports and in clinical settings as well. PMID:23486361

  10. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  11. Peripheral retinopathy in offspring of carriers of Norrie disease gene mutations. Possible transplacental effect of abnormal Norrin.

    Science.gov (United States)

    Mintz-Hittner, H A; Ferrell, R E; Sims, K B; Fernandez, K M; Gemmell, B S; Satriano, D R; Caster, J; Kretzer, F L

    1996-12-01

    The Norrie disease (ND) gene (Xp11.3) (McKusick 310600) consists of one untranslated exon and two exons partially translated as the Norrie disease protein (Norrin). Norrin has sequence homology and computer-predicted tertiary structure of a growth factor containing a cystine knot motif, which affects endothelial cell migration and proliferation. Norrie disease (congenital retinal detachment), X-linked primary retinal dysplasia (congenital retinal fold), and X-linked exudative vitreoretinopathy (congenital macular ectopia) are allelic disorders. Blood was drawn for genetic studies from members of two families to test for ND gene mutations. Sixteen unaffected family members were examined ophthalmologically. If any retinal abnormality were identified, fundus photography and fluorescein angiography was performed. Family A had ND (R109stp), and family B had X-linked exudative vitreoretinopathy (R121L). The retinas of 11 offspring of carrier females were examined: three of seven carrier females, three of three otherwise healthy females, and one of one otherwise healthy male had peripheral inner retinal vascular abnormalities. The retinas of five offspring of affected males were examined: none of three carrier females and none of two otherwise healthy males had this peripheral retinal finding. Peripheral inner retinal vascular abnormalities similar to regressed retinopathy of prematurity were identified in seven offspring of carriers of ND gene mutations in two families. These ophthalmologic findings, especially in four genetically healthy offspring, strongly support the hypothesis that abnormal Norrin may have an adverse transplacental (environmental) effect on normal inner retinal vasculogenesis.

  12. The Relationship of Digit Ratio (2D:4D) with Cerebral Lateralization and Grip Strength in Elite Swimmers

    Science.gov (United States)

    Acar, Hakan; Eler, Nebahat

    2018-01-01

    The index finger and the 4th finger ratio (2D:4D) is the indicator of the prenatal testosterone. The aim of this study is to investigate the relationship between 2D:4D, hand preference and hand grip strength in swimmers. A total of 80 elite swimmers, participated in the study. Height, body weight, body mass index (BMI), hand 2D:4D finger…

  13. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  14. Refuelling machine for nuclear reactor

    International Nuclear Information System (INIS)

    Shumyakin, E.P.; Sabir-de-Ribas, K.I.; Druzhinsky, I.A.; Shishov, G.P.; Andreichikov, B.I.

    1979-01-01

    The proposed manipulating means consists of housing, wherein a gripping means is arranged to grip a fuel assembly being transferred. The gripping means is coupled to a drive having a chain which is in contact with a sprocket mounted on an axle arranged in the sealed housing. The driving force of the drive is transmitted to the gripping means. The driving force is controlled by a force regulator mounted on the gripping means. The force regulator comprises two force tranducers mounted on the sealed housing, and a spring suspension member installed in the gripping means. Some clearance is allowed where the drive sprocket axle is secured in the walls of the sealed housing. The ends of the axle extend outside the sealed housing and are coupled to sensitive elements of the force transducers

  15. Research Advances in CKLFSF-like MARVEL Transmembrane Domain Containing Member 3.

    Science.gov (United States)

    Hu, Feng-zhan; Sheng, Zheng-zuo; Qin, Cai-peng; Xu, Tao

    2016-06-10

    CKLF-like MARVEL transmembrane domain containing member/chemokine-like factor super family member (CKLFSF/CMTM) is a novel tumor suppressor gene. CMTM3 is broadly expressed in normal human tissues and evolutionary conserved,especially in testis,spleen,and some cells of peripheral blood mononuclear cells. However,its expression is undetectable or down-regulated in most carcinoma cell lines and tissues. Restoration of CMTM3 may inhibit the proliferation,migration,and invasion of carcinoma cells. Although the exact mechanism of its anti-tumor activity remains unclear,CKLFSF3/CMTM3 is closely connected with immune system and associated with sex during tumorigenesis. The study advances of CKLFSF3/CMTM3 are elaborated in this review as CMTM3 may be a new target in the gene therapies for tumors,especially genitourinary tumors,while further studies on CMTM3 and its anti-tumor mechanisms are warranted.

  16. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  17. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  18. Improving communication on hope in palliative care. A qualitative study of palliative care professionals' metaphors of hope: grip, source, tune, and vision.

    Science.gov (United States)

    Olsman, Erik; Duggleby, Wendy; Nekolaichuk, Cheryl; Willems, Dick; Gagnon, Judith; Kruizinga, Renske; Leget, Carlo

    2014-11-01

    Hope is important in palliative care. However, palliative care professionals' perspectives on hope are not well understood. Metaphors of hope are a way of better understanding these perspectives. To describe palliative care professionals' perspectives on hope by examining the hope metaphors they spontaneously used to describe their own hope and their perspectives on the hope of patients and their families. Semistructured interviews with palliative care professionals were recorded, transcribed, and analyzed using a narrative approach. Results were discussed until the researchers reached consensus and reinforced by other health-care professionals and by observing several palliative care settings. The 64 participants (mean (SD) age, 48.42 (9.27) years and 72% female) were physicians (41%), nurses (34%), chaplains (20%), or other professionals (5%), working in Canada (19%) or The Netherlands (81%). Participants described the hope of patients, their families, or themselves as a 1) grip, which implied safety; 2) source, which implied strength; 3) tune, which implied harmony; and 4) vision, which implied a positive perspective. Compared with Dutch participants, Canadian participants generally put more emphasis on spirituality and letting go of their own hope as a grip (safety). Compared with other included professionals, physicians used hope as a grip (safety) most often, whereas chaplains used hope as a tune (harmony) most often. Our findings help to increase the understanding of hope and contribute to improving communication skills in palliative care professionals. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  19. Grip Force and 3D Push-Pull Force Estimation Based on sEMG and GRNN

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2017-06-01

    Full Text Available The estimation of the grip force and the 3D push-pull force (push and pull force in the three dimension space from the electromyogram (EMG signal is of great importance in the dexterous control of the EMG prosthetic hand. In this paper, an action force estimation method which is based on the eight channels of the surface EMG (sEMG and the Generalized Regression Neural Network (GRNN is proposed to meet the requirements of the force control of the intelligent EMG prosthetic hand. Firstly, the experimental platform, the acquisition of the sEMG, the feature extraction of the sEMG and the construction of GRNN are described. Then, the multi-channels of the sEMG when the hand is moving are captured by the EMG sensors attached on eight different positions of the arm skin surface. Meanwhile, a grip force sensor and a three dimension force sensor are adopted to measure the output force of the human's hand. The characteristic matrix of the sEMG and the force signals are used to construct the GRNN. The mean absolute value and the root mean square of the estimation errors, the correlation coefficients between the actual force and the estimated force are employed to assess the accuracy of the estimation. Analysis of variance (ANOVA is also employed to test the difference of the force estimation. The experiments are implemented to verify the effectiveness of the proposed estimation method and the results show that the output force of the human's hand can be correctly estimated by using sEMG and GRNN method.

  20. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  1. Stable isotope ratio mass spectrometry and physical comparison for the forensic examination of grip-seal plastic bags.

    Science.gov (United States)

    Taylor, Erica; Carter, James F; Hill, Jenny C; Morton, Carolyn; Daeid, Niamh Nic; Sleeman, Richard

    2008-05-20

    Plastic bags are frequently used to package drugs, explosives and other contraband. There exists, therefore, a requirement in forensic casework to compare bags found at different locations. This is currently achieved almost exclusively by the use of physical comparisons such as birefringence patterns. This paper discusses some of the advantages and shortcomings of this approach, and presents stable isotope ratio mass spectrometry (IRMS) as a supplementary tool for effecting comparisons of this nature. Carbon and hydrogen isotopic data are presented for sixteen grip-seal plastic bags from a wide range of sources, in order to demonstrate the range of values which is likely to be encountered. Both isotopic and physical comparison (specifically birefringence) techniques are then applied to the analysis of rolls of bags from different manufacturing lots from a leading manufacturer. Both approaches are able to associate bags from a common production batch. IRMS can be applied to small fragments which are not amenable to physical comparisons, and is able to discriminate bags which could be confused using birefringence patterns alone. Similarly, in certain cases birefringence patterns discriminate bags with similar isotopic compositions. The two approaches are therefore complementary. When more than one isotopically distinct region exists within a bag (e.g. the grip-seal is distinct from the body) the ability to discriminate and associate bags is greatly increased.

  2. The association between physical activity and risk of mortality is modulated by grip strength and cardiorespiratory fitness: evidence from 498 135 UK-Biobank participants

    Science.gov (United States)

    Celis-Morales, Carlos A.; Lyall, Donald M.; Anderson, Jana; Iliodromiti, Stamatina; Fan, Yu; Ntuk, Uduakobong E.; Mackay, Daniel F.; Pell, Jill P.; Sattar, Naveed; Gill, Jason M.R.

    2017-01-01

    Aims It is unclear whether the potential benefits of physical activity differ according to level of cardiorespiratory fitness (CRF) or strength. The aim of this study was to determine whether the association between physical activity and mortality is moderated by CRF and grip strength sufficiently to inform health promotion strategies. Methods and results 498 135 participants (54.7% women) from the UK Biobank were included (CRF data available in 67 702 participants). Exposure variables were grip strength, CRF, and physical activity. All-cause mortality and cardiovascular disease (CVD) events were the outcomes. 8591 died over median 4.9 years [IQR 4.3–5.5] follow-up. There was a significant interaction between total physical activity and grip strength (P interaction with CRF did not reach statistical significance but the pattern was similar. The association between physical activity and mortality was larger among those in the lowest tertile of CRF (HR:1.13 [1.02–1.26]) than those in the highest (HR:1.03 [0.91–1.16]). The pattern for CVD events was similar. Conclusions These data provide novel evidence that strength, and possibly CRF, moderate the association between physical activity and mortality. The association between physical activity and mortality is strongest in those with the lowest strength (which is easily measured), and the lowest CRF, suggesting that these sub-groups could benefit most from interventions to increase physical activity. PMID:28158566

  3. Coming to Grips with Breast Cancer: The Spouse’s Experience with His Wife’s First Six Months

    OpenAIRE

    Zahlis, Ellen H.; Lewis, Frances M.

    2010-01-01

    This study examines the experiences of 48 spouses of wives newly diagnosed with local or regional breast cancer. Their reported experiences were organized into the core construct of Coming to Grips reflected by four domains: (1) Feeling nailed by the breast cancer; (2) Changing us; (3) Taking care of me; and (4) Making things work. Prior studies have underestimated the extent to which the assumptive world and day-to-day lives of spouses are shattered by the diagnosis of breast cancer and the ...

  4. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  5. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  6. Associations of Walking Speed, Grip Strength, and Standing Balance With Total and Cause-Specific Mortality in a General Population of Japanese Elders.

    Science.gov (United States)

    Nofuji, Yu; Shinkai, Shoji; Taniguchi, Yu; Amano, Hidenori; Nishi, Mariko; Murayama, Hiroshi; Fujiwara, Yoshinori; Suzuki, Takao

    2016-02-01

    Walking speed, grip strength, and standing balance are key components of physical performance in older people. The present study aimed to evaluate (1) associations of these physical performance measures with cause-specific mortality, (2) independent associations of individual physical performance measures with mortality, and (3) the added value of combined use of the 3 physical performance measures in predicting all-cause and cause-specific mortality. Prospective cohort study with a follow-up of 10.5 years. Tokyo Metropolitan Institute of Gerontology Longitudinal Interdisciplinary Study on Aging (TMIG-LISA), Japan. A total of 1085 initially nondisabled older Japanese aged 65 to 89 years. Usual walking speed, grip strength, and standing balance were measured at baseline survey. During follow-up, 324 deaths occurred (122 of cardiovascular disease, 75 of cancer, 115 of other causes, and 12 of unknown causes). All 3 physical performance measures were significantly associated with all-cause, cardiovascular, and other-cause mortality, but not with cancer mortality, independent of potential confounders. When all 3 physical performance measures were simultaneously entered into the model, each was significantly independently associated with all-cause and cardiovascular mortality. The C statistics for all-cause and cardiovascular mortality were significantly increased by adding grip strength and standing balance to walking speed (P balance predicted all-cause, cardiovascular, and other-cause mortality, but not cancer mortality, independent of covariates. Moreover, these 3 components of physical performance were independently associated with all-cause and cardiovascular mortality and their combined use increased prognostic power. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  7. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  8. Ücretsiz mevsimsel grip aşılarını yaptıran kişilerin, ücretsiz pandemik grip aşısı karşısındaki tutum ve davranışları

    Directory of Open Access Journals (Sweden)

    Muzaffer Eskiocak

    2011-09-01

    Full Text Available Amaç: Bu çalışma, mevsimsel grip aşısına (MGA ücretsiz erişen insanların tutum ve davranışlarını, yine ücretsiz, ama çeşitli tartışmalara konu olan pandemik grip aşısı (PGA karşısındaki tutum ve davranışlarıyla karşılaştırmak amacıyla yapılmıştır. Yöntem: Araştırma tanımlayıcı tipte bir araştırmadır ve Kırklareli-Evrensekiz Sağlık Ocağı bölgesinde, Şubat,2009–Şubat,2010 tarihleri arasında yürütülmüştür. Çalışma anketi yüz-yüze görüşme yöntemiyle doldurulmuştur. Bulgular: Katılımcıların %99,2’si (n=125 kamu kurumlarının ücretsiz MGA sağlamasını destekliyordu ve tamamı (N=126 gelecek yıl da ücretsiz MGA temin edilmesini istiyordu. 2010 yılında yapılan ikinci ankette ücretsiz sağlanan PGA olanların oranının ise %4 (n=5 olduğu tespit edildi. Sonuç: Bağışıklama hizmetlerinden yararlanmada ekonomik faktörlerin çok önemli olduğu, ancak toplumun güven duygusunun zedelenmesinin, ücretsiz sağlansa da aşılamayı ciddi düzeyde engellediği saptanmıştır.Anahtar Kelimeler: Mevsimsel grip aşısı, pandemik grip aşısı Attitudes and behaviors related to free pandemic influenza vaccination of who gets vaccinated with free seasonal influenza vaccine  Objective: This study aims to compare attitudes and behaviors of the people who receive free Seasonal Influenza Vaccine (SIV with their attitudes and behaviors against Pandemic Influenza Vaccine (PIV which is also free, but controversial. Method: This study is a descriptive survey which was carried out within the service area of Evrensekiz Primary Healthcare Center (PHC in Kırklareli province and it was conducted between February 2009 and February 2010. The questionnaire has been applied by face to face interviews. Results: 99,2%of participants (n=125 supported providing free influenza vaccine by governmental organizations and all of them (N=126 wanted to get free influenza vaccine the next year

  9. Medial Elbow Joint Space Increases With Valgus Stress and Decreases When Cued to Perform A Maximal Grip Contraction.

    Science.gov (United States)

    Pexa, Brett S; Ryan, Eric D; Myers, Joseph B

    2018-04-01

    Previous research indicates that the amount of valgus torque placed on the elbow joint during overhead throwing is higher than the medial ulnar collateral ligament (UCL) can tolerate. Wrist and finger flexor muscle activity is hypothesized to make up for this difference, and in vitro studies that simulated activity of upper extremity musculature, specifically the flexor digitorum superficialis and flexor carpi ulnaris, support this hypothesis. To assess the medial elbow joint space at rest, under valgus stress, and under valgus stress with finger and forearm flexor contraction by use of ultrasonography in vivo. Controlled laboratory study. Participants were 22 healthy males with no history of elbow dislocation or UCL injury (age, 21.25 ± 1.58 years; height, 1.80 ± 0.08 m; weight, 79.43 ± 18.50 kg). Medial elbow joint space was measured by use of ultrasonography during 3 separate conditions: at rest (unloaded), under valgus load (loaded), and with a maximal grip contraction under a valgus load (loaded-contracted) in both limbs. Participants lay supine with their arm abducted 90° and elbow flexed 30° with the forearm in full supination. A handgrip dynamometer was placed in the participants' hand to grip against during the contracted condition. Images were reduced in ImageJ to assess medial elbow joint space. A 2-way (condition × limb) repeated-measures analysis of variance and Cohen's d effect sizes were used to assess changes in medial elbow joint space. Post hoc testing was performed with a Bonferroni adjustment to assess changes within limb and condition. The medial elbow joint space was significantly larger in the loaded condition (4.91 ± 1.16 mm) compared with the unloaded condition (4.26 ± 1.23 mm, P space increases under a valgus load and then decreases when a maximal grip contraction is performed. This indicates that wrist and finger flexor muscle contraction may assist in limiting medial elbow joint space, a result similar to findings of previous

  10. Isometric hand grip strength measured by the Nintendo Wii Balance Board - a reliable new method.

    Science.gov (United States)

    Blomkvist, A W; Andersen, S; de Bruin, E D; Jorgensen, M G

    2016-02-03

    Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson's product-moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

  11. Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis.

    Science.gov (United States)

    Schiefer, Matthew; Tan, Daniel; Sidek, Steven M; Tyler, Dustin J

    2016-02-01

    Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject's sense of embodiment with a survey and his self-confidence. Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.

  12. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  13. PERIPHERAL AVASCULAR RETINA WITH DISK ANOMALY AND HIGH MYOPIA: A Novel Association in a Hereditary Isolated Ocular Disorder.

    Science.gov (United States)

    Habib, Ahmed M; Elkitkat, Rania S; Saleh, Mohamed I; Abd El-Salam, Mohammed M

    2016-02-01

    To describe a family pedigree with a previously undescribed association of autosomal dominantly inherited ocular abnormalities. Case series study performed on 15 family members. Examination included history taking, visual acuity, intraocular pressure, slit-lamp, gonioscopy, indirect ophthalmoscopy (10 members), fluorescein angiography (5 members), general examination and renal ultrasound (4 members), and hemoglobin electrophoresis for the proband and another member. Family pedigree revealed autosomal-dominant inheritance. Visual acuity ranged from 6/36 to no light perception. Examination revealed rubeosis in 7 eyes and atrophia bulbi in 11 eyes. Indirect ophthalmoscopy for 11 eyes revealed evidence of an ocular triad of peripheral avascular retina, disk anomaly (cavitary optic disk anomaly or disk dysplasia), and tessellated fundus of high myopia. The authors also observed new vessels elsewhere with or without extensive subretinal exudations in 6 eyes. All patients with any residual vision (up to perception of light) had nystagmus. Four affected members underwent general examination, renal ultrasound, and serum creatinine level (to exclude papillorenal syndrome), and all were normal. Hemoglobin electrophoresis (to exclude sickle cell retinopathy) revealed within normal values. To the authors' knowledge, the aforementioned ocular triad has not been previously described, in association, with an autosomal-dominant pattern of inheritance.

  14. White matter organization in cervical spinal cord relates differently to age and control of grip force in healthy subjects.

    Science.gov (United States)

    Lindberg, Påvel G; Feydy, Antoine; Maier, Marc A

    2010-03-17

    Diffusion tensor imaging (DTI) can be used to elucidate relations between CNS structure and function. We hypothesized that the degree of spinal white matter organization relates to the accuracy of control of grip force. Healthy subjects of different age were studied using DTI and visuomotor tracking of precision grip force. The latter is a prime component of manual dexterity. A regional analysis of spinal white matter [fractional anisotropy (FA)] across multiple cervical levels (C2-C3, C4-C5, and C6-C7) and in different regions of interest (left and right lateral or medial spinal cord) was performed. FA was highest at the C2-C3 level, higher on the right than the left side, and higher in the lateral than in the medial spinal cord (p level in the lateral spinal cord, in which the corticospinal tract innervates spinal circuitry controlling hand and digit muscles. FA of the medial spinal cord correlated consistently with age across all cervical levels, whereas FA of the lateral spinal cord did not. The results suggest (1) a functionally relevant specialization of lateral spinal cord white matter and (2) an increased sensitivity to age-related decline in medial spinal cord white matter in healthy subjects.

  15. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  16. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.

    Science.gov (United States)

    Yang, Xu; Wu, Qinfen; Lai, Chin-Hui; Wang, Xin

    2017-10-01

    We present a modified tension band technique combined with cable cerclage using Cable Grip System for the treatment of displaced inferior patellar pole fractures and report the knee functional outcome. The patients who had had operative treatment of a displaced inferior patellar pole fracture (AO/OTA 34-A1) between December 2013 and December 2015 were studied retrospectively. Eleven consecutive patients had had open reduction and internal fixation with the modified technique using Cable Grip System, of whom, five males and six females with an average age of 60.9 years (range, 29-81 years). All fractures occurred from direct fall onto the knee. The average time from injury to surgery was 6.1days (range, 2-12days). The range of motion (ROM) was measured in degrees by goniometry at postoperative intervals of 1, 2, 4, 12, and 48 weeks; Knee function was evaluated using the Rasmussen scores at final follow-up. No patients had nonunion, loss of reduction, migration of wire, irritation from the implant and fixation breakage during the follow-up period. Recovery of ROM was achieved at 12 weeks, with the average ROM at 1 week was 72° (range, 65°-78°), 86.4° (range, 78°-92°) at 2 weeks, 115.5° (range, 103°-122°) at 4 weeks, 129.6° (range, 122°-133°) at 12 weeks, 134.5° (range, 129°-139°) at 48 weeks after the operation. Concerning the knee function outcome assessment, all patients showed excellent results at final follow-up. The average Rasmussen scores was 27.9 out of 30 (range, 27-29). The modified tension band technique combined with cable cerclage using Cable Grip System for displaced inferior patellar pole fractures can provide stable fixation with excellent results in knee function, allows for immediate mobilization and early weight-bearing, which is a simple and valuable technique in routine clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. A little similarity goes a long way: the effects of peripheral but self-revealing similarities on improving and sustaining interracial relationships.

    Science.gov (United States)

    West, Tessa V; Magee, Joe C; Gordon, Sarah H; Gullett, Lindy

    2014-07-01

    Integrating theory on close relationships and intergroup relations, we construct a manipulation of similarity that we demonstrate can improve interracial interactions across different settings. We find that manipulating perceptions of similarity on self-revealing attributes that are peripheral to the interaction improves interactions in cross-race dyads and racially diverse task groups. In a getting-acquainted context, we demonstrate that the belief that one's different-race partner is similar to oneself on self-revealing, peripheral attributes leads to less anticipatory anxiety than the belief that one's partner is similar on peripheral, nonself-revealing attributes. In another dyadic context, we explore the range of benefits that perceptions of peripheral, self-revealing similarity can bring to different-race interaction partners and find (a) less anxiety during interaction, (b) greater interest in sustained contact with one's partner, and (c) stronger accuracy in perceptions of one's partners' relationship intentions. By contrast, participants in same-race interactions were largely unaffected by these manipulations of perceived similarity. Our final experiment shows that among small task groups composed of racially diverse individuals, those whose members perceive peripheral, self-revealing similarity perform superior to those who perceive dissimilarity. Implications for using this approach to improve interracial interactions across different goal-driven contexts are discussed.

  18. The Impact of Financial and Economic Crisis on EU-27 Member States’ Balance of Payments

    Directory of Open Access Journals (Sweden)

    Simona Moagăr-Poladian

    2013-04-01

    Full Text Available The object of the present article is to analyze the impact of 2008 financial and economic crisis on the evolution of balance of payment of EU-27 member states. Specifically, the analyzed period is between the years 2006-2011. The article is structured in the following parts: (1 the analysis of the evolution of the current account and capital account balance in the EU27 with non-EU states, (2 the identification of the main factors of disparities and asymmetries between the Euro area member states concerning current account balance and international investment position; (3 the role of TARGET2 system in financing of current account deficits of the peripheral countries of Euro area, and capital flight from these states to other Euro area countries perceived as less risky by investors.

  19. The use of self-gripping (Progrip™) mesh during laparoscopic total extraperitoneal (TEP) inguinal hernia repair: a prospective feasibility and long-term outcomes study.

    Science.gov (United States)

    Bresnahan, Erin; Bates, Andrew; Wu, Andrew; Reiner, Mark; Jacob, Brian

    2015-09-01

    The use of self-gripping mesh during laparoscopic TEP inguinal hernia repairs may eliminate the need for any additional fixation, and thus reduce post-operative pain without the added concern for mesh migration. Long-term outcomes are not yet prospectively studied in a controlled fashion. Under IRB approval, from January 2011-April 2013, 91 hernias were repaired laparoscopically with self-gripping mesh without additional fixation. Patients were followed for at least 1 year. Demographics and intraoperative data (defect location, size, and mesh deployment time) are recorded. VAS is used in the recovery room (RR) to score pain, and the Carolinas Comfort Scale ™ (CCS), a validated 0-5 pain/quality of life (QoL) score where a mean score of >1.0 means symptomatic pain, is employed at 2 weeks and at 1 year. Morbidities, narcotic usage, days to full activity and return to work, and CCS scores are reported. Sixty two patients, with 91 hernias repaired with self-gripping mesh, completed follow-up at a mean time period of 14.8 months. Seventeen hernias were direct defects (average size 3.0 cm). Mesh deployment time was 193.7 s. RR pain was 1.1/10 using a VAS. Total average oxycodone/acetaminophen (5 mg/325 mg) usage = 5.0 tablets, days to full activity was 1.6, and return to work was 4.2 days. Thirteen small asymptomatic seromas were palpated without any recurrences or groin tenderness, and all seromas resolved by the 6 month visit. Transient testis discomfort was reported in five patients. Urinary retention was 3.2%. Mean CCS™ scores at the first visit for groin pain laying, bending, sitting, walking, and step-climbing were 0.2, 0.5, 0.4, 0.3, and 0.3, respectively. At the first post op visit, 4.8% had symptomatic pain (CCS > 1). At 14.8 months, no patients reported symptomatic pain with CCS scores for all 62 patients averaging 0.02, (range 0-0.43). There are no recurrences thus far. Self-gripping mesh can be safely used during laparoscopic TEP inguinal hernia repairs

  20. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Functional deficits in peripheral nerve mitochondria in rats with paclitaxel- and oxaliplatin-evoked painful peripheral neuropathy

    OpenAIRE

    Zheng, Huaien; Xiao, Wen Hua; Bennett, Gary J.

    2011-01-01

    Cancer chemotherapeutics like paclitaxel and oxaliplatin produce a dose-limiting chronic sensory peripheral neuropathy that is often accompanied by neuropathic pain. The cause of the neuropathy and pain is unknown. In animal models, paclitaxel-evoked and oxaliplatin-evoked painful peripheral neuropathies are accompanied by an increase in the incidence of swollen and vacuolated mitochondria in peripheral nerve axons. It has been proposed that mitochondrial swelling and vacuolation are indicati...

  2. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    Science.gov (United States)

    Young, J.N.

    1958-04-22

    An electromagnetic apparatus for moving a rod-like member in small steps in either direction is described. The invention has particular application in the reactor field where the reactor control rods must be moved only a small distance and where the use of mechanical couplings is impractical due to the high- pressure seals required. A neutron-absorbing rod is mounted in a housing with gripping uaits that engage the rod, and coils for magnetizing the gripping units to make them grip, shift, and release the rod are located outside the housing.

  4. Synaptic and functional linkages between spinal premotor interneurons and hand-muscle activity during precision grip

    Directory of Open Access Journals (Sweden)

    Tomohiko eTakei

    2013-04-01

    Full Text Available Grasping is a highly complex movement that requires the coordination of a number of hand joints and muscles. Previous studies showed that spinal premotor interneurons (PreM-INs in the primate cervical spinal cord have divergent synaptic effects on hand motoneurons and that they might contribute to hand-muscle synergies. However, the extent to which these PreM-IN synaptic connections functionally contribute to modulating hand-muscle activity is not clear. In this paper, we explored the contribution of spinal PreM-INs to hand-muscle activation by quantifying the synaptic linkage (SL and functional linkage (FL of the PreM-INs with hand-muscle activities. The activity of 23 PreM-INs was recorded from the cervical spinal cord (C6–T1, with EMG signals measured simultaneously from hand and arm muscles in two macaque monkeys performing a precision grip task. Spike-triggered averages (STAs of rectified EMGs were compiled for 456 neuron–muscle pairs; 63 pairs showed significant post-spike effects (i.e., SL. Conversely, 231 of 456 pairs showed significant cross-correlations between the IN firing rate and rectified EMG (i.e., FL. Importantly, a greater proportion of the neuron–muscle pairs with SL showed FL (43/63 pairs, 68% compared with the pairs without SL (203/393, 52%, and the presence of SL was significantly associated with that of FL. However, a significant number of pairs had SL without FL (SL∩!FL, n = 20 or FL without SL (!SL∩FL, n = 203, and the proportions of these incongruities exceeded the number expected by chance. These results suggested that spinal PreM-INs function to significantly modulate hand-muscle activity during precision grip, but the contribution of other neural structures is also needed to recruit an adequate combination of hand-muscle motoneurons.

  5. Long term clinical outcome of peripheral nerve stimulation in patients with chronic peripheral neuropathic pain

    DEFF Research Database (Denmark)

    Calenbergh, F. Van; Gybels, J.; Laere, K. Van

    2009-01-01

    BACKGROUND: Chronic neuropathic pain after injury to a peripheral nerve is known to be resistant to treatment. Peripheral nerve stimulation is one of the possible treatment options, which is, however, not performed frequently. In recent years we have witnessed a renewed interest for PNS. The aim...... of the present study was to evaluate the long-term clinical efficacy of PNS in a group of patients with peripheral neuropathic pain treated with PNS since the 1980s. METHODS: Of an original series of 11 patients, 5 patients could be invited for clinical examination, detailed assessment of clinical pain and QST...... functioning) also showed positive effects. Quantitative Sensory Testing results did not show significant differences in cold pain and heat pain thresholds between the "ON" and "OFF" conditions. CONCLUSION: In selected patients with peripheral neuropathic pain PNS remains effective even after more than 20...

  6. Evaluation of finger A3 pulley rupture in the crimp grip position - a magnetic resonance imaging cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Uder, Michael; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Adler, Werner [University of Erlangen-Nuremberg, Department of Biometry and Epidemiology, Erlangen (Germany); Schweizer, Andreas [Balgrist, University of Zurich, Department of Orthopaedics, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany)

    2015-09-15

    The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture. MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured. Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm. Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture. (orig.)

  7. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  8. Altered Cytokine Gene Expression in Peripheral Blood Monocytes across the Menstrual Cycle in Primary Dysmenorrhea: A Case-Control Study

    Science.gov (United States)

    Ma, Hongyue; Hong, Min; Duan, Jinao; Liu, Pei; Fan, Xinsheng; Shang, Erxin; Su, Shulan; Guo, Jianming; Qian, Dawei; Tang, Yuping

    2013-01-01

    Primary dysmenorrhea is one of the most common gynecological complaints in young women, but potential peripheral immunologic features underlying this condition remain undefined. In this paper, we compared 84 common cytokine gene expression profiles of peripheral blood mononuclear cells (PBMCs) from six primary dysmenorrheic young women and three unaffected controls on the seventh day before (secretory phase), and the first (menstrual phase) and the fifth (regenerative phase) days of menstruation, using a real-time PCR array assay combined with pattern recognition and gene function annotation methods. Comparisons between dysmenorrhea and normal control groups identified 11 (nine increased and two decreased), 14 (five increased and nine decreased), and 15 (seven increased and eight decreased) genes with ≥2-fold difference in expression (Pdysmenorrhea. This first study of cytokine gene expression profiles in PBMCs from young primary dysmenorrheic women demonstrates a shift in the balance between expression patterns of pro-inflammatory cytokines and TGF-β superfamily members across the whole menstrual cycle, underlying the peripheral immunologic features of primary dysmenorrhea. PMID:23390521

  9. Grip op werkstress. Mindfulness ontstresst maatschappelijk werkers

    Directory of Open Access Journals (Sweden)

    Jen van Horen

    2014-03-01

    Full Text Available Taking control over work related stress. Mindfulness destresses social workersStress is a major social problem. Due to the increasing workload and the content of the work, social workers are at risk to develop stress (symptoms. The physical and psychological consequences of prolonged stress are serious. By living healthy, optimize working conditions and applying mindfulness, stress can be reduced. Mindfulness is an effective and useful way to reduce stress. It increases the resistance of workers against stress, improves brainfunctions and therefore has a positive effect on the performance. These effects are great, but they are still weakly methodologically substantiated. A pilot project within the youthcare though, was enthusiastically received and proves to be effective against stress symptoms. The exercises that are part of this pilot fit well with the needs of employees. For organizations mindfulnesstrainings are a time-and cost-effective way of structural stress prevention.Grip op werkstress. Mindfulness ontstresst maatschappelijk werkersStress is een omvangrijk maatschappelijk probleem. Door de toenemende werkdruk en de inhoud van het werk zijn maatschappelijk werkers een risicogroep om stress en stressklachten te ontwikkelen. De fysieke en psychische gevolgen die langdurige stress met zich meebrengt zijn ernstig. Door gezond te leven, de arbeidsomstandigheden te optimaliseren en mindfulness toe te passen kan stress terug worden gedrongen. Mindfulness is een effectieve en bruikbare manier om stress te verminderen. Het vergroot de weerbaarheid van werknemers tegen stress, het verbetert de hersenwerking en heeft daardoor een positief effect op het functioneren. Grote effecten dus, maar wel nog methodologisch zwak onderbouwd. Een pilot binnen de jeugdzorg op het gebied van mindfulness is enthousiast ontvangen en blijkt effectief tegen stressklachten. De oefeningen die onderdeel uitmaken van deze pilot sluiten goed aan bij de behoeften van

  10. Treatment of painful diabetic peripheral neuropathy.

    Science.gov (United States)

    Rosenberg, Casandra J; Watson, James C

    2015-02-01

    Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. To discuss current treatment recommendations for painful diabetic peripheral neuropathy. Literature review. Systematic review of the literature discussing treatment of painful diabetic peripheral neuropathy. Existing treatment guidelines were studied and compared. Painful diabetic peripheral neuropathy occurs in about one in six people with diabetes. This condition impairs quality of life and increases healthcare costs. Treatment recommendations exist, but individual patient therapy can require a trial-and-error approach. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. Adequate medication titration and a reasonable trial period should be allowed. The treatment of painful diabetic peripheral neuropathy can be challenging, but effective management can improve patient's quality of life. Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. © The International Society for Prosthetics and Orthotics 2014.

  11. Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis

    Science.gov (United States)

    Schiefer, Matthew; Tan, Daniel; Sidek, Steven M.; Tyler, Dustin J.

    2016-02-01

    Objective. Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. Approach. Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject’s sense of embodiment with a survey and his self-confidence. Main results. Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. Significance. Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.

  12. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Peripheral neuropathy in HIV: prevalence and risk factors

    Science.gov (United States)

    Evans, Scott R.; Ellis, Ronald J.; Chen, Huichao; Yeh, Tzu-min; Lee, Anthony J.; Schifitto, Giovanni; Wu, Kunling; Bosch, Ronald J.; McArthur, Justin C.; Simpson, David M.; Clifford, David B.

    2011-01-01

    Objectives To estimate neuropathic sign/symptom rates with initiation of combination antiretroviral therapy (cART) in HIV-infected ART-naive patients, and to investigate risk factors for: peripheral neuropathy and symptomatic peripheral neuropathy (SPN), recovery from peripheral neuropathy/SPN after neurotoxic ART (nART) discontinuation, and the absence of peripheral neuropathy/SPN while on nART. Design AIDS Clinical Trials Group (ACTG) Longitudinal Linked Randomized Trial participants who initiated cART in randomized trials for ART-naive patients were annually screened for symptoms/signs of peripheral neuropathy. ART use and disease characteristics were collected longitudinally. Methods Peripheral neuropathy was defined as at least mild loss of vibration sensation in both great toes or absent/hypoactive ankle reflexes bilaterally. SPN was defined as peripheral neuropathy and bilateral symptoms. Generalized estimating equation logistic regression was used to estimate associations. Results Two thousand, one hundred and forty-one participants were followed from January 2000 to June 2007. Rates of peripheral neuropathy/SPN at 3 years were 32.1/8.6% despite 87.1% with HIV-1RNA 400 copies/ml or less and 70.3% with CD4 greater than 350 cells/µl. Associations with higher odds of peripheral neuropathy included older patient age and current nART use. Associations with higher odds of SPN included older patient age, nART use, and history of diabetes mellitus. Associations with lower odds of recovery after nART discontinuation included older patient age. Associations with higher odds of peripheral neuropathy while on nART included older patient age and current protease inhibitor use. Associations with higher odds of SPN while on nART included older patient age, history of diabetes, taller height, and protease inhibitor use. Conclusion Signs of peripheral neuropathy remain despite virologic/immunologic control but frequently occurs without symptoms. Aging is a risk factor for

  14. Peripheral Vestibular System Disease in Vestibular Schwannomas

    DEFF Research Database (Denmark)

    Møller, Martin Nue; Hansen, Søren; Caye-Thomasen, Per

    2015-01-01

    density of the peripheral vestibular nerve branches, and atrophy of the neuroepithelium of the vestibular end organs. In cases with small tumors, peripheral disease occurred only in the tissue structures innervated by the specific nerve from which the tumor originated. CONCLUSION: Vestibular schwannomas...... are associated with distinctive disease of the peripheral vestibular tissue structures, suggesting anterograde degeneration and that dizziness in these patients may be caused by deficient peripheral vestibular nerve fibers, neurons, and end organs. In smaller tumors, a highly localized disease occurs, which...

  15. Desert hedgehog promotes ischemia-induced angiogenesis by ensuring peripheral nerve survival.

    Science.gov (United States)

    Renault, Marie-Ange; Chapouly, Candice; Yao, Qinyu; Larrieu-Lahargue, Frédéric; Vandierdonck, Soizic; Reynaud, Annabel; Petit, Myriam; Jaspard-Vinassa, Béatrice; Belloc, Isabelle; Traiffort, Elisabeth; Ruat, Martial; Duplàa, Cécile; Couffinhal, Thierry; Desgranges, Claude; Gadeau, Alain-Pierre

    2013-03-01

    Blood vessel growth and patterning have been shown to be regulated by nerve-derived signals. Desert hedgehog (Dhh), one of the Hedgehog family members, is expressed by Schwann cells of peripheral nerves. The purpose of this study was to investigate the contribution of Dhh to angiogenesis in the setting of ischemia. We induced hindlimb ischemia in wild-type and Dhh(-/-) mice. First, we found that limb perfusion is significantly impaired in the absence of Dhh. This effect is associated with a significant decrease in capillary and artery density in Dhh(-/-). By using mice in which the Hedgehog signaling pathway effector Smoothened was specifically invalidated in endothelial cells, we demonstrated that Dhh does not promote angiogenesis by a direct activation of endothelial cells. On the contrary, we found that Dhh promotes peripheral nerve survival in the ischemic muscle and, by doing so, maintains the pool of nerve-derived proangiogenic factors. Consistently, we found that denervation of the leg, immediately after the onset of ischemia, severely impairs ischemia-induced angiogenesis and decreases expression of vascular endothelial growth factor A, angiopoietin 1, and neurotrophin 3 in the ischemic muscle. This study demonstrates the crucial roles of nerves and factors regulating nerve physiology in the setting of ischemia-induced angiogenesis.

  16. Hypothyroidism: Can It Cause Peripheral Neuropathy?

    Science.gov (United States)

    Hypothyroidism: Can it cause peripheral neuropathy? Can hypothyroidism cause peripheral neuropathy and, if so, how is it treated? Answers from Todd B. Nippoldt, M.D. Hypothyroidism — a condition in which your ...

  17. Peripheral ameloblastic fibro-odontoma or peripheral developing complex odontoma: report of a case

    DEFF Research Database (Denmark)

    Reibel, Jesper; Grønbæk, Anni Birgitte; Poulsen, Sven

    2011-01-01

    BACKGROUND. Peripheral (extraosseous) odontogenic tumors are rare. CASE REPORT. This report describes a case which illustrates the clinical and histopathological features of a lesion in an 8-year-old, healthy Caucasian girl that on purely morphological grounds would seem to be an ameloblastic fibro-odontoma......, but may represent a case of a peripheral developing complex odontoma. CONCLUSION. Conservative surgical enucleation of the lesion was followed by unbcomplicated healing and no recurrence was seen....

  18. Promoting peripheral myelin repair

    OpenAIRE

    Zhou, Ye; Notterpek, Lucia

    2016-01-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the ...

  19. Peripheral cemento-ossifying fibroma of maxilla.

    Science.gov (United States)

    Chatterjee, Anirban; Ajmera, Neha; Singh, Amit

    2010-07-01

    Peripheral cemento-ossifying fibroma is a reactive gingival overgrowth occurring frequently in anterior maxilla. It is a slow-growing benign tumor which may lead to pathologic migration and other periodontal problems, so it should be excised as soon as possible. The recurrence rate of peripheral cemento-ossifying fibroma is reported to be 8% to 20%, so a close postoperative follow-up is required. Herein, we are reporting a similar case of peripheral cemento-ossifying fibroma in the maxillary anterior region.

  20. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  1. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  2. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  3. Light-Absorbing Aerosol during NASA GRIP: Overview of Observations in the Free Troposphere and Associated with Tropical Storm Systems

    Science.gov (United States)

    Ziemba, L. D.; Beyersdorf, A. J.; Chen, G.; Corr, C. A.; Craig, L.; Dhaniyala, S.; Dibb, J. E.; Hudgins, C. H.; Ismail, S.; Latham, T.; Nenes, A.; Thornhill, K. L.; Winstead, E.; Anderson, B. E.

    2010-12-01

    Aerosols play a significant role in regulating Earth’s climate. Absorbing aerosols typically constitute a small fraction of ambient particle mass but can contribute significantly to direct and indirect climate forcing depending on size, mixing state, concentration, chemical composition, and vertical and spatial distribution. Aerosols may also significantly affect tropical storm/hurricane dynamics through direct light absorption and activation as cloud nuclei. An extensive suite of instrumentation measuring aerosol chemical, physical, and optical properties was deployed aboard the NASA DC-8 to characterize aerosol during the NASA GRIP (Genesis and Rapid Intensification Processes; August-September 2010) mission. The majority of flight time was spent at high altitude (greater than 9 km) and thus much of the sampling was done in the free troposphere, including extensive sampling in the vicinity of tropical storm systems and more diffuse cirrus clouds. With operations based in Fort Lauderdale, FL and St. Croix, U.S. Virgin Islands, a large geographic region was sampled including much of the Gulf of Mexico and tropical Atlantic Ocean. Observations are reported for light-absorbing carbon aerosol (mainly black carbon, BC) primarily using a single particle soot photometer (SP2). The SP2 employs single-particle laser-induced incandescence to provide a mass-specific measurement not subject to scattering interference that is optimal for the low concentration environments like those encountered during GRIP. BC mass concentrations, 100-500 nm size distributions, and mixing state (i.e. coating thickness of scattering material) are presented. Total and sub-micron aerosol absorption coefficients (principally from BC and dust aerosol) are reported using a particle soot absorption photometer (PSAP) along with comparisons with calculated absorption coefficients derived from SP2 observations in various conditions. In addition, dust aerosol is specifically identified using optical and

  4. Peripheral Neuropathy – Clinical and Electrophysiological Considerations

    Science.gov (United States)

    Chung, Tae; Prasad, Kalpana; Lloyd, Thomas E.

    2013-01-01

    This article is a primer on the pathophysiology and clinical evaluation of peripheral neuropathy for the radiologist. Magnetic resonance neurography (MRN) has utility in the diagnosis of many focal peripheral nerve lesions. When combined with history, examination, electrophysiology, and laboratory data, future advancements in high-field MRN may play an increasingly important role in the evaluation of patients with peripheral neuropathy. PMID:24210312

  5. Does a history of physical exposures at work affect hand-grip strength in midlife?

    DEFF Research Database (Denmark)

    Møller, Anne; Reventlow, Susanne; Hansen, Åse Marie

    2013-01-01

    were non-linear and primarily positive among men. Among women, the associations were non-linear and, according to ton-years, primarily negatively associated with HGS but statistically insignificant. CONCLUSION: A history of physical exposures at work explained only a minor part of the variation in HGS......OBJECTIVE: The aim of this cohort study was to examine associations between physical exposures throughout working life and hand-grip strength (HGS) in midlife. METHODS: The Copenhagen Aging and Midlife Biobank (CAMB) provided data about employment and HGS for 3843 Danes. Individual job histories......, including duration of employment in specific jobs, were assigned exposures from a job exposure matrix. Exposures were standardized to ton-years (lifting 1000 kg each day in one year), stand-years (standing/walking for six hours each day in one year) and kneel-years (kneeling for one hour each day in one...

  6. The challenges and beauty of peripheral nerve regrowth.

    Science.gov (United States)

    Zochodne, Douglas W

    2012-03-01

    This review provides an overview of selected aspects of peripheral nerve regeneration and potential avenues to explore therapeutically. The overall coordinated and orchestrated pattern of recovery from peripheral nerve injury has a beauty of execution and progress that rivals all other forms of neurobiology. It involves changes at the level of the perikaryon, coordination with important peripheral glial partners, the Schwann cells, a controlled inflammatory response, and growth that overcomes surprising intrinsic roadblocks. Both regenerative axon growth and collateral sprouting encompass fascinating aspects of this story. Better understanding of peripheral nerve regeneration may also lead to enhanced central nervous system recovery. © 2012 Peripheral Nerve Society.

  7. Odontogenic keratocyst: a peripheral variant.

    Science.gov (United States)

    Vij, H; Vij, R; Gupta, V; Sengupta, S

    2011-01-01

    Odontogenic keratocyst, which is developmental in nature, is an intraosseous lesion though on rare occasions it may occur in an extraosseous location. The extraosseous variant is referred to as peripheral odontogenic keratocyst. Though, clinically, peripheral odontogenic keratocyst resembles the gingival cyst of adults, it has histologic features that are pathognomonic of odontogenic keratocyst. This article presents a case of this uncommon entity.

  8. Effects of glovebox gloves on grip and key pinch strength and contact forces for simulated manual operations with three commonly used hand tools.

    Science.gov (United States)

    Sung, Peng-Cheng

    2014-01-01

    This study examined the effects of glovebox gloves for 11 females on maximum grip and key pinch strength and on contact forces generated from simulated tasks of a roller, a pair of tweezers and a crescent wrench. The independent variables were gloves fabricated of butyl, CSM/hypalon and neoprene materials; two glove thicknesses; and layers of gloves worn including single, double and triple gloving. CSM/hypalon and butyl gloves produced greater grip strength than the neoprene gloves. CSM/hypalon gloves also lowered contact forces for roller and wrench tasks. Single gloving and thin gloves improved hand strength performances. However, triple layers lowered contact forces for all tasks. Based on the evaluating results, selection and design recommendations of gloves for three hand tools were provided to minimise the effects on hand strength and optimise protection of the palmar hand in glovebox environments. To improve safety and health in the glovebox environments where gloves usage is a necessity, this study provides recommendations for selection and design of glovebox gloves for three hand tools including a roller, a pair of tweezers and a crescent wrench based on the results discovered in the experiments.

  9. Integrated treatment modality of cathodal-transcranial direct current stimulation with peripheral sensory stimulation affords neuroprotection in a rat stroke model.

    Science.gov (United States)

    Liu, Yu-Hang; Chan, Su Jing; Pan, Han-Chi; Bandla, Aishwarya; King, Nicolas K K; Wong, Peter Tsun Hon; Chen, You-Yin; Ng, Wai Hoe; Thakor, Nitish V; Liao, Lun-De

    2017-10-01

    Cathodal-transcranial direct current stimulation induces therapeutic effects in animal ischemia models by preventing the expansion of ischemic injury during the hyperacute phase of ischemia. However, its efficacy is limited by an accompanying decrease in cerebral blood flow. On the other hand, peripheral sensory stimulation can increase blood flow to specific brain areas resulting in rescue of neurovascular functions from ischemic damage. Therefore, the two modalities appear to complement each other to form an integrated treatment modality. Our results showed that hemodynamics was improved in a photothrombotic ischemia model, as cerebral blood volume and hemoglobin oxygen saturation ([Formula: see text]) recovered to 71% and 76% of the baseline values, respectively. Furthermore, neural activities, including somatosensory-evoked potentials (110% increase), the alpha-to-delta ratio (27% increase), and the [Formula: see text] ratio (27% decrease), were also restored. Infarct volume was reduced by 50% with a 2-fold preservation in the number of neurons and a 6-fold reduction in the number of active microglia in the infarct region compared with the untreated group. Grip strength was also better preserved (28% higher) compared with the untreated group. Overall, this nonpharmacological, nonintrusive approach could be prospectively developed into a clinical treatment modality.

  10. Effect of low appendicular lean mass, grip strength, and gait speed on the functional outcome after surgery for distal radius fractures.

    Science.gov (United States)

    Roh, Young Hak; Noh, Jung Ho; Gong, Hyun Sik; Baek, Goo Hyun

    2017-12-01

    Patients with low appendicular lean mass plus slow gait speed or weak grip strength are at risk for poor functional recovery after surgery for distal radius fracture, even when they have similar radiologic outcomes. Loss of skeletal muscle mass and consequent loss in muscle function associate with aging, and this condition negatively impacts the activities of daily living and increases elderly individuals' frailty to falls. Thus, patients with low appendicular lean mass would show different functional recovery compared to those without this condition after surgery for distal radius fracture (DRF). This study compares the functional outcomes after surgery for DRF in patients with or without low appendicular lean mass plus slowness or weakness. A total of 157 patients older than 50 years of age with a DRF treated via volar plate fixation were enrolled in this prospective study. A definition of low appendicular lean mass with slowness or weakness was based on the consensus of the Asian Working Group for Sarcopenia. The researchers compared functional assessments (wrist range of motion and Michigan Hand Questionnaire [MHQ]) and radiographic assessments (radial inclination, volar tilt, ulnar variance, and articular congruity) 12 months after surgery between patients with and without low appendicular lean mass plus slowness or weakness. Multivariable regression analyses were performed to determine whether appendicular lean mass, grip strength, gait speed, patient demographic, or injury characteristics accounted for the functional outcomes. Patients with low appendicular lean mass plus slowness or weakness showed a significantly lower recovery of MHQ score than those in the control group throughout 12 months. There was no significant difference in the range of motion between the groups. The radiologic outcomes showed no significant difference between groups in terms of volar tilt, radial inclination, or ulnar variance. According to multivariable regression analysis

  11. Synovial sarcoma mimicking benign peripheral nerve sheath tumor

    Energy Technology Data Exchange (ETDEWEB)

    Larque, Ana B.; Nielsen, G.P.; Chebib, Ivan [Massachusetts General Hospital and Harvard Medical School, Department of Pathology, Boston, MA (United States); Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-11-15

    To assess the radiographic and clinicopathologic features of synovial sarcoma of the nerve that were clinically or radiologically interpreted as benign peripheral nerve sheath tumor. Five patients with synovial sarcoma arising from the peripheral nerve and interpreted clinically and radiologically as peripheral nerve sheath tumors were identified. Clinicopathologic and imaging features were evaluated. There were three females and two males, ranging in age from 28 to 50 (mean 35.8) years. Most patients (4/5) complained of a mass, discomfort or pain. MR images demonstrated a heterogeneous, enhancing, soft tissue mass contiguous with the neurovascular bundle. On histologic examination, most tumors were monophasic synovial sarcoma (4/5). At the time of surgery, all tumors were noted to arise along or within a peripheral nerve. All patients were alive with no evidence of disease with median follow-up of 44 (range 32-237) months. For comparison, approximately 775 benign peripheral nerve sheath tumors of the extremities were identified during the same time period. Primary synovial sarcoma of the nerve can mimic peripheral nerve sheath tumors clinically and on imaging and should be included in the differential diagnosis for tumors arising from peripheral nerves. (orig.)

  12. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  13. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  14. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  15. Peripheral facial weakness (Bell's palsy).

    Science.gov (United States)

    Basić-Kes, Vanja; Dobrota, Vesna Dermanović; Cesarik, Marijan; Matovina, Lucija Zadro; Madzar, Zrinko; Zavoreo, Iris; Demarin, Vida

    2013-06-01

    Peripheral facial weakness is a facial nerve damage that results in muscle weakness on one side of the face. It may be idiopathic (Bell's palsy) or may have a detectable cause. Almost 80% of peripheral facial weakness cases are primary and the rest of them are secondary. The most frequent causes of secondary peripheral facial weakness are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immune disorders, drugs, degenerative diseases of the central nervous system, etc. The diagnosis relies upon the presence of typical signs and symptoms, blood chemistry tests, cerebrospinal fluid investigations, nerve conduction studies and neuroimaging methods (cerebral MRI, x-ray of the skull and mastoid). Treatment of secondary peripheral facial weakness is based on therapy for the underlying disorder, unlike the treatment of Bell's palsy that is controversial due to the lack of large, randomized, controlled, prospective studies. There are some indications that steroids or antiviral agents are beneficial but there are also studies that show no beneficial effect. Additional treatments include eye protection, physiotherapy, acupuncture, botulinum toxin, or surgery. Bell's palsy has a benign prognosis with complete recovery in about 80% of patients, 15% experience some mode of permanent nerve damage and severe consequences remain in 5% of patients.

  16. A Triple-Masked, Randomized Controlled Trial Comparing Ultrasound-Guided Brachial Plexus and Distal Peripheral Nerve Block Anesthesia for Outpatient Hand Surgery

    Directory of Open Access Journals (Sweden)

    Nicholas C. K. Lam

    2014-01-01

    Full Text Available Background. For hand surgery, brachial plexus blocks provide effective anesthesia but produce undesirable numbness. We hypothesized that distal peripheral nerve blocks will better preserve motor function while providing effective anesthesia. Methods. Adult subjects who were scheduled for elective ambulatory hand surgery under regional anesthesia and sedation were recruited and randomly assigned to receive ultrasound-guided supraclavicular brachial plexus block or distal block of the ulnar and median nerves. Each subject received 15 mL of 1.5% mepivacaine at the assigned location with 15 mL of normal saline injected in the alternate block location. The primary outcome (change in baseline grip strength measured by a hydraulic dynamometer was tested before the block and prior to discharge. Subject satisfaction data were collected the day after surgery. Results. Fourteen subjects were enrolled. Median (interquartile range [IQR] strength loss in the distal group was 21.4% (14.3, 47.8%, while all subjects in the supraclavicular group lost 100% of their preoperative strength, P = 0.001. Subjects in the distal group reported greater satisfaction with their block procedures on the day after surgery, P = 0.012. Conclusion. Distal nerve blocks better preserve motor function without negatively affecting quality of anesthesia, leading to increased patient satisfaction, when compared to brachial plexus block.

  17. CT characteristics of peripheral organizing pneumonia

    International Nuclear Information System (INIS)

    Yang, Seong Oh; Choi, Chul Soon; Kim, Myung Joon; Lee, Kyung Soo; Choi, Hyung Sik; Jun, Young Hwan; Park, Yong Koo

    1988-01-01

    Diagnostic dilemma of persistent mass-forming parenchymal opacity in the lung periphery occurs occasionally in the realm of diagnostic radiology. Until recently, literature on the role of computed tomography in peripheral organizing pneumonia, which is difficult to differentiate from malignancy, has little been published. We experienced one case of pathologically proven organizing pneumonia diagnosed preoperatively by chest CT. When it comes to solitary peripheral mass density in the lung, we think that CT can be proved useful in the diagnosis of benign organizing pneumonia by showing regular and smoothly corrugate margin, peripheral contrast enhancement with inner low density, and air-trapping by intervening normal lung parenchyma.

  18. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  19. Fuel pin transfer tool

    International Nuclear Information System (INIS)

    Patenaude, R. S.

    1985-01-01

    A fuel pin transfer tool has a latching device of the collet type attached to a first member movable vertically through a long work stroke enabling a fuel pin in an under water assembly to be engaged and withdrawn therefrom or placed therein and released. The latching device has a collet provided with a plurality of resilient fingers having cam portions normally spaced apart to receive the upper end of a fuel pin between them and a second member, movable vertically through a short stroke relative to the first member is provided with cam portions engageable with those of the fingers and is yieldably and resiliently held in a raised position in which its cam portions engage those of the fingers and force the fingers into their pin-gripping positions. When a predetermined force is applied to the second member, it is so moved that its cam portions are disengaged from the cam portions of the fingers permitting the latter to move into their normal relationship in which a gripped pin is released or another pin received but with their pin-gripping relationship positively re-established and maintained once the force on the tubular member is lessened. Movement of the first member in either direction and movement of the second member into its raised position is attended by forces inadequate to affect the integrity of fuel pin cladding. That force is applied in the preferred embodiment, by a power operated actuator which is within the upper portion of a housing and, in the preferred embodiment, carried by the long stroke member but always in the upper housing portion which is of a material sufficiently translucent to enable the actuator to be observed throughout the work stroke and is sufficiently light in weight to prevent the tool from being top heavy

  20. [Peripheral retinal degenerations--treatment recommendations].

    Science.gov (United States)

    Joussen, A M; Kirchhof, B

    2004-10-01

    This report reviews the clinical appearance of degenerative diseases of the peripheral retina in relationship to the risk of developing a rhegmatogenous retinal detachment. We present recommendations for preventive treatment in eyes at increased risk of developing retinal detachment. Retinal degenerations are common lesions involving the peripheral retina but most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and very rarely zonular traction tufts can result in rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic treatment; however, adequate studies have not been performed to date. Most of the peripheral retinal degenerations may not require treatment except in rare, high-risk situations. According to current knowledge there is no higher incidence of secondary pucker or other side effects after laser coagulation. Therefore, generous laser indication is recommended if risk factors apply.

  1. The glacial inception as recorded in the NorthGRIP Greenland ice core: timing, structure and associated abrupt temperature changes

    Energy Technology Data Exchange (ETDEWEB)

    Landais, Amaelle [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Hebrew University, Institute of Earth Sciences, Givat Ram, Jerusalem (Israel); Masson-Delmotte, Valerie; Jouzel, Jean; Minster, Benedicte [UMR CEA-CNRS, CEA Saclay, IPSL/Laboratoire des Sciences du Climat et de l' Environnement, Gif-sur -Yvette (France); Raynaud, Dominique [LGGE, UMR CNRS-UJF, St Martin d' Heres (France); Johnsen, Sigfus [University of Copenhagen, Department of Geophysics, Copenhagen (Denmark); Huber, Christof; Leuenberger, Markus; Schwander, Jakob [University of Bern, Physics Institute, Bern (Switzerland)

    2006-02-01

    The mechanisms involved in the glacial inception are still poorly constrained due to a lack of high resolution and cross-dated climate records at various locations. Using air isotopic measurements in the recently drilled NorthGRIP ice core, we show that no evidence exists for stratigraphic disturbance of the climate record of the last glacial inception ({proportional_to}123-100 kyears BP) encompassing Dansgaard-Oeschger events (DO) 25, 24 and 23, even if we lack sufficient resolution to completely rule out disturbance over DO 25. We quantify the rapid surface temperature variability over DO 23 and 24 with associated warmings of 10{+-}2.5 and 16{+-}2.5 C, amplitudes which mimic those observed in full glacial conditions. We use records of {delta}{sup 18}O of O{sub 2} to propose a common timescale for the NorthGRIP and the Antarctic Vostok ice cores, with a maximum uncertainty of 2,500 years, and to examine the interhemispheric sequence of events over this period. After a synchronous North-South temperature decrease, the onset of rapid events is triggered in the North through DO 25. As for later events, DO 24 and 23 have a clear Antarctic counterpart which does not seem to be the case for the very first abrupt warming (DO 25). This information, when added to intermediate levels of CO{sub 2} and to the absence of clear ice rafting associated with DO 25, highlights the uniqueness of this first event, while DO 24 and 23 appear similar to typical full glacial DO events. (orig.)

  2. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  3. Peripheral Ulcerative Keratitis

    Science.gov (United States)

    ... oval in shape. Diagnosis A doctor's evaluation Sometimes culture The diagnosis of peripheral ulcerative keratitis is suspected when the doctor sees the affected cornea in a person who also has a severe and/or long- ...

  4. Hyperacute peripheral neuropathy is a predictor of oxaliplatin-induced persistent peripheral neuropathy.

    Science.gov (United States)

    Tanishima, Hiroyuki; Tominaga, Toshiji; Kimura, Masamichi; Maeda, Tsunehiro; Shirai, Yasutsugu; Horiuchi, Tetsuya

    2017-05-01

    Chronic peripheral neuropathy is a major adverse response to oxaliplatin-containing chemotherapy regimens, but there are no established risk factors pertaining to it. We investigated the efficacy of hyperacute peripheral neuropathy (HAPN) as a predictor of oxaliplatin-induced persistent peripheral neuropathy (PPN). Forty-seven cases of stage III colorectal cancer who received adjuvant chemotherapy with oxaliplatin after curative surgery between January 2010 and August 2014 were retrospectively reviewed. HAPN was defined as acute peripheral neuropathy (APN) occurring on day 1 (≤24 h after oxaliplatin infusion) of the first cycle. PPN was defined as neuropathy lasting >1 year after oxaliplatin discontinuation. The average total dose of oxaliplatin was 625.8 mg/m 2 , and the average relative dose intensity was 66.7%. Twenty-two of the 47 patients (46.8%) had PPN and 13 (27.7%) had HAPN. Male sex, treatment for neuropathy, HAPN, and APN were significantly more frequent in patients with PPN (p = 0.013, 0.02, <0.001, and 0.023, respectively). There was no significant difference in the total oxaliplatin dose between patients with and without PPN (p = 0.061). Multivariate analyses revealed total dose of oxaliplatin and HAPN as independent predictors of PPN [p = 0.015; odds ratio (OR) = 1.005, 95% confidence interval (CI), 1.001-1.009 and p = 0.001; OR = 75.307, 5.3-1070.123, respectively]. The total dose of oxaliplatin was relatively lower in patients with HAPN than that in those without HAPN in the PPN-positive group (not significant, p = 0.068). HAPN was found to be a predictor of oxaliplatin-induced PPN.

  5. Studies of peripheral sensory nerves in paclitaxel-induced painful peripheral neuropathy: Evidence for mitochondrial dysfunction

    OpenAIRE

    Flatters, Sarah J.L.; Bennett, Gary J.

    2006-01-01

    Paclitaxel chemotherapy frequently induces neuropathic pain during and often persisting after therapy. The mechanisms responsible for this pain are unknown. Using a rat model of paclitaxel-induced painful peripheral neuropathy, we have performed studies to search for peripheral nerve pathology. Paclitaxel-induced mechano-allodynia and mechano-hyperalgesia were evident after a short delay, peaked at day 27 and finally resolved on day 155. Paclitaxel- and vehicle-treated rats were perfused on d...

  6. Hip muscle and hand-grip strength to differentiate between older fallers and non-fallers: a cross-sectional validity study

    Directory of Open Access Journals (Sweden)

    Gafner SC

    2017-12-01

    Full Text Available Simone C Gafner,1,2 Caroline H Bastiaenen,2,3 Serge Ferrari,4 Gabriel Gold,5 Philippe Terrier,6,7 Roger Hilfiker,8 Lara Allet1,91Department of Physiotherapy, HES-SO University of Applied Sciences and Arts of Western Switzerland, Geneva, Switzerland; 2Department of Epidemiology, Research Program Functioning and Rehabilitation, CAPHRI, Maastricht University, Maastricht, the Netherlands; 3Department of Health, School of Health Professions, Zurich University of Applied Sciences, Winterthur, 4Department of Internal Medicine Specialties, 5Department of Internal Medicine, Rehabilitation and Geriatrics, University Hospitals and University of Geneva, Geneva, 6Department of Research, Clinique romande de réadaptation SUVACare, 7Department of Research, Institute for Research in Rehabilitation, Sion, 8Department of Physiotherapy, School of Health Sciences, HES-SO Valais-Wallis, University of Applied Sciences and Arts of Western Switzerland, Valais, 9Department of Community Medicine, University Hospitals and University of Geneva, Geneva, Switzerland Background: Hip muscle weakness in older people seems to be an influencing factor of falls. Currently, it is unclear which muscles out of the hip muscle group play an important role in older people. A validating process in the measurement regarding muscle strength related to falls is necessary before answering that question.Objective: Firstly, we aimed to investigate which hip muscle group strength shows an acceptable level of distinction between older adult fallers and non-fallers compared to a predefined external criterion regarding falling. Secondly, we aimed to compare the same outcomes and questions for hand-grip strength in relation to the same external criterion.Design: This study was a cross-sectional validity study.Methods: The maximum voluntary isometric strength (MVIS and the rate of force generation of hip abductors (ABD, adductors, internal and external rotators, extensors, and flexors were measured

  7. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  8. Unipedal stance testing in the assessment of peripheral neuropathy.

    Science.gov (United States)

    Hurvitz, E A; Richardson, J K; Werner, R A

    2001-02-01

    To define further the relation between unipedal stance testing and peripheral neuropathy. Prospective cohort. Electroneuromyography laboratory of a Veterans Affairs medical center and a university hospital. Ninety-two patients referred for lower extremity electrodiagnostic studies. A standardized history and physical examination designed to detect peripheral neuropathy, 3 trials of unipedal stance, and electrodiagnostic studies. Peripheral neuropathy was identified by electrodiagnostic testing in 32%. These subjects had a significantly shorter (p unipedal stance time (15.7s, longest of 3 trials) than the patients without peripheral neuropathy (37.1s). Abnormal unipedal stance time (unipedal stance time had a negative predictive value of 90%. Abnormal unipedal stance time was associated with an increased risk of having peripheral neuropathy on univariate analysis (odds ratio = 8.8, 95% confidence interval = 2.5--31), and was the only significant predictor of peripheral neuropathy in the regression model. Aspects of the neurologic examination did not add to the regression model compared with abnormal unipedal stance time. Unipedal stance testing is useful in the clinical setting both to identify and to exclude the presence of peripheral neuropathy.

  9. Lipid-lowering drugs (statins) and peripheral neuropathy.

    Science.gov (United States)

    Emad, Mohammadreza; Arjmand, Hosein; Farpour, Hamid Reza; Kardeh, Bahareh

    2018-03-01

    Peripheral neuropathy is a disorder with often unknown causes. Some drugs, including statins, are proposed to be among the causes of peripheral neuropathy. This study aimed at evaluating this condition by electrodiagnostic study among patients who had received statins. This case-control study was conducted in Shiraz, Iran in 2015, and included 39 patients aged 35-55 who had received statins for at least 6 months, and 39 healthy matched controls. Using electrodiagnosis, the sensory and motor wave features (amplitude, latency and nerve conduction velocity) of the peripheral nerves (Median, Ulnar, Tibial, Sural, and Peroneal) were evaluated among the subjects. Data were analyzed using SPSS software and pneuropathy, there were no significant differences in any of the definitions presented for peripheral neuropathy. However, the difference was close to significance for one definition [2 abnormalities in 2 nerves (p=0.055)]. Regarding mean values of the features, significant differences were observed in two features: amplitude of the peroneal motor nerve (p=0.048) and amplitude of the sural sensory nerve (p=0.036). Since statins are widely used, awareness regarding their side-effects would lead to better treatment. Even though no significant differences were found between the groups regarding the occurrence of peripheral neuropathy, there were significant differences in amplitudes of the sural sensory response and the peroneal motor response. This indicates the involvement of peripheral nerves. Therefore, we recommend that patients and physicians should be informed about the possible symptoms of this condition.

  10. Comparative cervical profiles of adult and under-18 front-row rugby players: implications for playing policy

    Science.gov (United States)

    Hamilton, D F; Gatherer, D; Robson, J; Graham, N; Rennie, N; MacLean, J G B; Simpson, A H R W

    2014-01-01

    Objective To compare the cervical isometric strength, fatigue endurance and range of motion of adult and under-18 age-grade front-row rugby players to inform the development of a safe age group policy with particular reference to scrummaging. Design Cross-sectional cohort study. Setting ‘Field testing’ at Murrayfield stadium. Participants 30 high-performance under-18 players and 22 adult front-row rugby players. Outcome measures Isometric neck strength, height, weight and grip strength. Results Youth players demonstrated the same height and grip strength as the adult players; however, the adults were significantly heavier and demonstrated substantially greater isometric strength (prugby players demonstrate the same peripheral strength as their adult counterparts on grip testing, the adults demonstrate significantly greater cervical strength. If older youths and adults are to play together, such findings have to be noted in the development of age group policies with particular reference to the scrum. PMID:24797427

  11. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  12. Haemopoietic progenitor cells in human peripheral blood

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1980-01-01

    The purpose of the investigation reported is to purify haemopoietic progenitor cells from human peripheral blood using density gradient centrifugation in order to isolate a progenitor cell fraction without immunocompetent cells. The purification technique of peripheral blood flow colony forming unit culture (CFU-c) by means of density gradient centrifugation and a combined depletion of various rosettes is described. The results of several 'in vitro' characteristics of purified CFU-c suspensions and of the plasma clot diffusion chamber culture technique are presented. Irradiation studies revealed that for both human bone marrow and peripheral blood the CFU-c were less radioresistant than clusters. Elimination of monocytes (and granulocytes) from the test suspensions induced an alteration in radiosensitivity pararmeters. The results obtained with the different techniques are described by analysing peripheral progenitor cell activity in myeloproliferative disorders. (Auth.)

  13. Label-free photoacoustic microscopy of peripheral nerves

    Science.gov (United States)

    Matthews, Thomas Paul; Zhang, Chi; Yao, Da-Kang; Maslov, Konstantin; Wang, Lihong V.

    2014-01-01

    Peripheral neuropathy is a common neurological problem that affects millions of people worldwide. Diagnosis and treatment of this condition are often hindered by the difficulties in making objective, noninvasive measurements of nerve fibers. Photoacoustic microscopy (PAM) has the ability to obtain high resolution, specific images of peripheral nerves without exogenous contrast. We demonstrated the first proof-of-concept imaging of peripheral nerves using PAM. As validated by both standard histology and photoacoustic spectroscopy, the origin of photoacoustic signals is myelin, the primary source of lipids in the nerves. An extracted sciatic nerve sandwiched between two layers of chicken tissue was imaged by PAM to mimic the in vivo case. Ordered fibrous structures inside the nerve, caused by the bundles of myelin-coated axons, could be observed clearly. With further technical improvements, PAM can potentially be applied to monitor and diagnose peripheral neuropathies.

  14. Peripheral Neuropathy and Nerve Compression Syndromes in Burns.

    Science.gov (United States)

    Strong, Amy L; Agarwal, Shailesh; Cederna, Paul S; Levi, Benjamin

    2017-10-01

    Peripheral neuropathy and nerve compression syndromes lead to substantial morbidity following burn injury. Patients present with pain, paresthesias, or weakness along a specific nerve distribution or experience generalized peripheral neuropathy. The symptoms manifest at various times from within one week of hospitalization to many months after wound closure. Peripheral neuropathy may be caused by vascular occlusion of vasa nervorum, inflammation, neurotoxin production leading to apoptosis, and direct destruction of nerves from the burn injury. This article discusses the natural history, diagnosis, current treatments, and future directions for potential interventions for peripheral neuropathy and nerve compression syndromes related to burn injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Peripheral orbit model

    CERN Document Server

    Hara, Yasuo

    1975-01-01

    Peripheral orbit model, in which an incoming hadron is assumed to revolve in a peripheral orbit around a target hadron, is discussed. The non-diffractive parts of two-body reaction amplitudes of hadrons are expressed in terms of the radius, width an absorptivity of the orbit. The radius of the orbit is about 1 fm and the width of the orbit is determined by the range of the interaction between the hadrons. The model reproduces all available experimental data on differential cross-sections and polarizations of $K^{-}p\\to K^{-}p$ and $\\bar K^{\\circ}n$ reactions for all angles successfully. This contribution is not included in the proceedings since it will appear in Progress of Theoretical Physics Vol. 51 (1974) No 2. Any person interested in the subject may apply for reprints to the author.

  16. Is salivary cortisol moderating the relationship between salivary testosterone and hand-grip strength in healthy men?

    Science.gov (United States)

    Crewther, Blair T; Thomas, Andrew G; Stewart-Williams, Steve; Kilduff, Liam P; Cook, Christian J

    2017-03-01

    This study examined the moderating effect of cortisol (C) on the relationship between testosterone (T) and hand-grip strength (HGS) in healthy young men. Sixty-five males were monitored for salivary T, C and HGS before and 15 min after a short bout (5 × 6-s trials) of sprint cycling exercise. Sprint exercise promoted (p moderating variable. The pre-test combination of high C and low T levels favoured absolute HGS, whereas low pre-test C levels and a smaller T change were linked to larger HGS changes. These associations suggest that, in the current format, T is not necessarily anabolic to muscle strength in healthy young men. Such complexities could also explain some of the inconsistent T relationships with physical performance in lesser trained male populations.

  17. Case report of a patient with peripheral facial nerve palsy

    OpenAIRE

    Rysová, Jana

    2013-01-01

    Title of bachelor's thesis: Case report of a patient with peripheral facial nerve palsy Summary: Teoretical part of bachelor's thesis contains theoretical foundation of peripheral facial nerve palsy. Practical part of bachelor's thesis contains physiotherapeutic case report of patient with peripheral facial nerve palsy. Key words: peripheral facial nerve palsy, casuistry, rehabilitation

  18. Peripheral involvement of the joint in seronegative spondylarthritis; Periphere Gelenkbeteiligung bei seronegativen Spondarthritiden

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Soltesz, I. [Rheumazentrum Bad Kreuznach (Germany). Zentrales Roentgeninstitut

    1997-10-01

    The subjects of this contributions have been restricted to the peripheral manifestations of seronegative spondylarthrosis, for reasons of conciseness and clearness. The most frequent occurrences discussed are psoriasis arthritis and, a little bit less frequent, peripheral involvement of the joint in ancylosing spondylitis and Reiter syndrome, as well as enteropathic spondylarthrosis. (orig./AJ) [Deutsch] Als Thema dieser Veroeffentlichung wurden aus Gruenden der Kuerze und der Uebersichtlichkeit aber nur die peripheren Manifestationen der seronegativen Spondarthropathien gewaehlt. Hier wiederum haben wir es am haeufigsten mit der Psoriasisarthritis und etwas seltener mit der peripheren Gelenkbeteiligung bei der Bechterew`schen Erkrankung und der Reiter`schen Erkrankung sowie der enteropathischen Spondarthritiden zu tun. (orig./AJ)

  19. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  20. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  1. Comprehension of handwriting development: Pen-grip kinetics in handwriting tasks and its relation to fine motor skills among school-age children.

    Science.gov (United States)

    Lin, Yu-Chen; Chao, Yen-Li; Wu, Shyi-Kuen; Lin, Ho-Hsio; Hsu, Chieh-Hsiang; Hsu, Hsiao-Man; Kuo, Li-Chieh

    2017-10-01

    Numerous tools have been developed to evaluate handwriting performances by analysing written products. However, few studies have directly investigated kinetic performances of digits when holding a pen. This study thus attempts to investigate pen-grip kinetics during writing tasks of school-age children and explore the relationship between the kinetic factors and fine motor skills. This study recruited 181 children aged from 5 to 12 years old and investigated the effects of age on handwriting kinetics and the relationship between these and fine motor skills. The forces applied from the digits and pen-tip were measured during writing tasks via a force acquisition pen, and the children's fine motor performances were also evaluated. The results indicate that peak force and average force might not be direct indicators of handwriting performance for normally developing children at this age. Younger children showed larger force variation and lower adjustment frequency during writing, which might indicate they had poorer force control than the older children. Force control when handling a pen is significantly correlated with fine motor performance, especially in relation to the manual dexterity. A novel system is proposed for analysing school-age children's force control while handwriting. We observed the development of force control in relation to pen grip among the children with different ages in this study. The findings suggested that manipulation skill may be crucial when children are establishing their handwriting capabilities. © 2017 Occupational Therapy Australia.

  2. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  3. Chronic obstructive pulmonary disease and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2006-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is the fourth leading cause of death world-wide and a further increase in the prevalence as well as mortality of the disease is predicted for coming decades. There is now an increased appreciation for the need to build awareness regarding COPD and to help the thousands of people who suffer from this disease and die prematurely from COPD or its associated complication(s. Peripheral neuropathy in COPD has received scanty attention despite the fact that very often clinicians come across COPD patients having clinical features suggestive of peripheral neuropathy. Electrophysiological tests like nerve conduction studies are required to distinguish between axonal and demyelinating type of disorder that cannot be analyzed by clinical examination alone. However, various studies addressing peripheral neuropathy in COPD carried out so far have included patients with COPD having markedly varying baseline characteristics like severe hypoxemia, elderly patients, those with long duration of illness, etc. that are not uniform across the studies and make it difficult to interpret the results to a consistent conclusion. Almost one-third of COPD patients have clinical evidence of peripheral neuropathy and two-thirds have electrophysiological abnormalities. Some patients with no clinical indication of peripheral neuropathy do have electrophysiological deficit suggestive of peripheral neuropathy. The more frequent presentation consists of a polyneuropathy that is subclinical or with predominantly sensory signs, and the neurophysiological and pathological features of predominantly axonal neuropathy. The presumed etiopathogenic factors are multiple: chronic hypoxia, tobacco smoke, alcoholism, malnutrition and adverse effects of certain drugs.

  4. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  5. A Non-Member Spouse's Entitlement To The Member's Pension Interest

    Directory of Open Access Journals (Sweden)

    Motseotsile Clement Marumoagae

    2014-12-01

    Full Text Available It is important that married couples seek legal advice with regard to the assets falling within their joint estate, more particularly their retirement benefits. This article reflects on the entitlement (if any of non-member spouses to their spouses' retirement fund benefits. Pension benefits can be due before, during or after divorce, and parties to the marriage should be aware of their rights with regard to the accruing pension benefits of their spouses. While it is settled law that non-member spouses are entitled to receive a portion of their member spouses' pension benefits (known as "pension interest" immediately on divorce, it is not particularly clear whether non-member spouses are also entitled to receive the same before or sometime after divorce. In this article I provide a contextual understanding of the entitlements (if any which spouses or former spouses of members of pension funds have on such member spouses' retirement benefits. Furthermore, it shown in this article that various divisions of South African High Courts have been inconsistent in how they have approached the issue of the pension interest between divorcing spouses or divorced ex-spouses.

  6. Peripheral Nervous System Manifestations in Systemic Autoimmune Diseases

    OpenAIRE

    COJOCARU, Inimioara Mihaela; COJOCARU, Manole; SILOSI, Isabela; VRABIE, Camelia Doina

    2014-01-01

    The peripheral nervous system refers to parts of the nervous system outside the brain and spinal cord. Systemic autoimmune diseases can affect both the central and peripheral nervous systems in a myriad of ways and through a heterogeneous number of mechanisms leading to many different clinical manifestations. As a result, neurological complications of these disorders can result in significant morbidity and mortality. The most common complication of peripheral nervous system (PNS) involvement ...

  7. Passive Scalar Evolution in Peripheral Region

    OpenAIRE

    Lebedev, V. V.; Turitsyn, K. S.

    2003-01-01

    We consider evolution of a passive scalar (concentration of pollutants or temperature) in a chaotic (turbulent) flow. A universal asymptotic behavior of the passive scalar decay (homogenization) related to peripheral regions (near walls) is established. The passive scalar moments and its pair correlation function in the peripheral region are analyzed. A special case investigated in our paper is the passive scalar decay along a pipe.

  8. Sustained effect of resistance training on blood pressure and hand grip strength following a detraining period in elderly hypertensive women: a pilot study

    Directory of Open Access Journals (Sweden)

    Nascimento D da C

    2014-01-01

    Full Text Available Dahan da Cunha Nascimento,1,5,8 Ramires Alsamir Tibana,1,8 Franklin M Benik,2 Keila Elizabeth Fontana,3 Frederico Ribeiro Neto,8 Frederico Santos de Santana,5,8 Leopoldo Santos-Neto,4 Renato André Sousa Silva,1,5,6 Alessandro Oliveira Silva,1,7 Darlan Lopes Farias,1,7 Sandor Balsamo,4,5,8 Jonato Prestes1 1Postgraduate Program in Physical Education, Catholic University of Brasilia, Brasilia, Brazil; 2Department of Kinesiology and Sports Studies Graduate Program, Eastern Illinois University, Charleston, IL, USA; 3Faculty of Physical Education, University of Brasilia, Brasilia, Brazil; 4Graduate Program in Medical Sciences of the University of Brasilia, School of Medicine and Rheumatology Service, University Hospital of Brasilia (HUB, Brasilia, Brazil; 5Department of Physical Education, University Center Euro American University Center, Brasilia, Brazil; 6Center of Excellence in Medicine of Exercise (CEMEx, Brasilia, Brazil; 7Center University of Brasilia (UNICEUB, Brasilia, Brazil; 8Strength Training and Health Research Group (GEPEEFS, Brasilia, Brazil Introduction: Hypertension is the most prevalent modifiable risk factor with a high prevalence among older adults. Exercise is a nonpharmacological treatment shown to benefit all patients with hypertension. Objective: This study examined the effects of a 14-week moderate intensity resistance training program (RT on the maintenance of blood pressure and hand grip strength during an extended detraining period in elderly hypertensive women. Methods: Twelve hypertensive sedentary elderly women completed 14 weeks of whole body RT at a moderate perceived exertion following a detraining period of 14 weeks. Results: Following the training period, participants demonstrated an increase in absolute hand grip strength (P=0.001, relative hand grip strength (P=0.032 and a decrease of systolic (P=0.001, diastolic (P=0.008, and mean blood pressure (P=0.002 when compared to pre-exercise values. In addition, these

  9. Imaging of the peripheral retina

    Directory of Open Access Journals (Sweden)

    Marcus Kernt

    2013-01-01

    Full Text Available The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO, digital angiography, optical coherence tomography (OCT, and detection of fundus autofluorescence (FAF have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina.

  10. Peripheral myelin protein 22 alters membrane architecture

    Science.gov (United States)

    Mittendorf, Kathleen F.; Marinko, Justin T.; Hampton, Cheri M.; Ke, Zunlong; Hadziselimovic, Arina; Schlebach, Jonathan P.; Law, Cheryl L.; Li, Jun; Wright, Elizabeth R.; Sanders, Charles R.; Ohi, Melanie D.

    2017-01-01

    Peripheral myelin protein 22 (PMP22) is highly expressed in myelinating Schwann cells of the peripheral nervous system. PMP22 genetic alterations cause the most common forms of Charcot-Marie-Tooth disease (CMTD), which is characterized by severe dysmyelination in the peripheral nerves. However, the functions of PMP22 in Schwann cell membranes remain unclear. We demonstrate that reconstitution of purified PMP22 into lipid vesicles results in the formation of compressed and cylindrically wrapped protein-lipid vesicles that share common organizational traits with compact myelin of peripheral nerves in vivo. The formation of these myelin-like assemblies depends on the lipid-to-PMP22 ratio, as well as on the PMP22 extracellular loops. Formation of the myelin-like assemblies is disrupted by a CMTD-causing mutation. This study provides both a biochemical assay for PMP22 function and evidence that PMP22 directly contributes to membrane organization in compact myelin. PMID:28695207

  11. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  12. Peripheral Osteoma of the Mandibular Notch: Report of a Case

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Izumi, Toshiharu; Baba, Junichi; Maegawa, Jiro; Mitsudo, Kenji; Tohnai, Iwai

    2013-01-01

    Osteoma is a benign, slow-growing osteogenic tumor that sometimes arises from the craniomaxillofacial region, such as the sinus, temporal or jaw bones. Osteoma consists of compact or cancellous bone that may be peripheral, central or extraskeletal type. Peripheral osteoma arises from the periosteum and is commonly a unilateral, pedunculated mushroom-like mass. Peripheral osteoma of the mandible is relatively uncommon, and peripheral osteoma of the mandibular notch is extremely rare, although many cases arise from the mandibular body, angle, condyle, or coronoid process. We report here an unusual peripheral osteoma of the mandibular notch in a 78-year-old nonsyndromic female

  13. Peripheral Primitive Neuroectodermal Tumor of the Stomach: A Case Report

    International Nuclear Information System (INIS)

    Park, Woon Ju; Cho, June Sik; Shin, Kyung Sook; Jeong, Hyung Yong; Noh; Seung Moo; Song, Kyu Sang

    2010-01-01

    Peripheral primitive neuroectodermal tumors (peripheral PNETs) are very rare and highly aggressive soft tissue malignancies originating from the neural crest. To the best of our knowledge, only a few cases of peripheral PNETs of the stomach have been reported in the literature. We report a case of large peripheral primitive neuroectodermal tumor of the stomach with MDCT findings in a 22-year-old man presenting epigastric pain and vomiting

  14. Peripheral T-Cell Lymphoma

    Science.gov (United States)

    ... Non-Hodgkin Lymphoma Peripheral T-Cell Lymphoma Primary Central Nervous System Lymphoma T-Cell Lymphoma Transformed Mycosis Fungoides Waldenstrom Macroglobulinemia Young Adult Lymphoma Overview Treatment Options Relapsed/Refractory Long-term ...

  15. Peripheral facial palsy in children.

    Science.gov (United States)

    Yılmaz, Unsal; Cubukçu, Duygu; Yılmaz, Tuba Sevim; Akıncı, Gülçin; Ozcan, Muazzez; Güzel, Orkide

    2014-11-01

    The aim of this study is to evaluate the types and clinical characteristics of peripheral facial palsy in children. The hospital charts of children diagnosed with peripheral facial palsy were reviewed retrospectively. A total of 81 children (42 female and 39 male) with a mean age of 9.2 ± 4.3 years were included in the study. Causes of facial palsy were 65 (80.2%) idiopathic (Bell palsy) facial palsy, 9 (11.1%) otitis media/mastoiditis, and tumor, trauma, congenital facial palsy, chickenpox, Melkersson-Rosenthal syndrome, enlarged lymph nodes, and familial Mediterranean fever (each 1; 1.2%). Five (6.1%) patients had recurrent attacks. In patients with Bell palsy, female/male and right/left ratios were 36/29 and 35/30, respectively. Of them, 31 (47.7%) had a history of preceding infection. The overall rate of complete recovery was 98.4%. A wide variety of disorders can present with peripheral facial palsy in children. Therefore, careful investigation and differential diagnosis is essential. © The Author(s) 2013.

  16. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  17. Members of the Agency

    International Nuclear Information System (INIS)

    2007-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.63) is Palau which deposited its Instrument of Acceptance of the Statute on 2 March 2007. The Attachment hereto shows the dates on which the present 144 Member States became Members [fr

  18. Members of the Agency

    International Nuclear Information System (INIS)

    2007-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.63) is Palau which deposited its Instrument of Acceptance of the Statute on 2 March 2007. The Attachment hereto shows the dates on which the present 144 Member States became Members [es

  19. Peripheral Protein Unfolding Drives Membrane Bending.

    Science.gov (United States)

    Siaw, Hew Ming Helen; Raghunath, Gokul; Dyer, R Brian

    2018-06-20

    Dynamic modulation of lipid membrane curvature can be achieved by a number of peripheral protein binding mechanisms such as hy-drophobic insertion of amphipathic helices and membrane scaffolding. Recently, an alternative mechanism was proposed in which crowding of peripherally bound proteins induces membrane curvature through steric pressure generated by lateral collisions. This effect was enhanced using intrinsically disordered proteins that possess high hydrodynamic radii, prompting us to explore whether membrane bending can be triggered by the folding-unfolding transition of surface-bound proteins. We utilized histidine-tagged human serum albumin bound to Ni-NTA-DGS containing liposomes as our model system to test this hypothesis. We found that reduction of the disulfide bonds in the protein resulted in unfolding of HSA, which subsequently led to membrane tubule formation. The frequency of tubule formation was found to be significantly higher when the proteins were unfolded while being localized to a phase-separated domain as opposed to randomly distributed in fluid phase liposomes, indicating that the steric pressure generated from protein unfolding is directly responsible for membrane deformation. Our results are critical for the design of peripheral membrane protein-immobilization strategies and open new avenues for exploring mechanisms of membrane bending driven by conformational changes of peripheral membrane proteins.

  20. 21 CFR 882.5870 - Implanted peripheral nerve stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ....5870 Implanted peripheral nerve stimulator for pain relief. (a) Identification. An implanted peripheral nerve stimulator for pain relief is a device that is used to stimulate electrically a peripheral nerve... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted peripheral nerve stimulator for pain...

  1. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  2. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  3. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  4. In the grip of the python: conflicts at the university-industry interface.

    Science.gov (United States)

    Healy, David

    2003-01-01

    When the University of Toronto withdrew a contract it held with me in December 2000, it initiated a sequence of events that led to a public letter to the University from senior figures in the world psychopharmacology community protesting against the infringement of academic freedom involved and a first ever legal action, undertake by this author, seeking redress for a violation of academic freedom. The issues of academic freedom surrounding this case have been intertwined with a debate about the possibility that the selective serotonin reuptake inhibitor (SSRI) group of antidepressants have the potential to trigger suicidality in a subgroup of patients. Whether the SSRIs do trigger suicidality or not, exploration of this issue has given rise to a number of worrying sets of observations. First, in my view, there is evidence that pharmaceutical companies have miscoded raw data on suicidal acts and suicidal ideation. Second, this author also maintains that there is a growing body of examples of ghostwriting of articles in the therapeutics domain. Many of the tensions evident in this case, therefore, can be linked to company abilities to keep clinical trial data out of the public domain--this is the point at which the pharmaceutical python gets a grip on academia.

  5. Management of peripheral facial nerve palsy

    OpenAIRE

    Finsterer, Josef

    2008-01-01

    Peripheral facial nerve palsy (FNP) may (secondary FNP) or may not have a detectable cause (Bell?s palsy). Three quarters of peripheral FNP are primary and one quarter secondary. The most prevalent causes of secondary FNP are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immunological disorders, or drugs. The diagnosis of FNP relies upon the presence of typical symptoms and signs, blood chemical investigations, cerebro-spinal-fluid-investigations, X-ray of the...

  6. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is frequently used for imaging peripheral nerves. It serves to supplement the physical examination, electromyography, and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive, well-tolerated by patients, and relatively inexpensive. Part I of this article series described in detail the characteristic USG picture of peripheral nerves and the proper examination technique, following the example of the median nerve. This nerve is among the most often examined peripheral nerves of the upper limb. This part presents describes the normal anatomy and ultrasound picture of the remaining large nerve branches in the upper extremity and neck – the spinal accessory nerve, the brachial plexus, the suprascapular, axillary, musculocutaneous, radial and ulnar nerves. Their normal anatomy and ultrasonographic appearance have been described, including the division into individual branches. For each of them, specific reference points have been presented, to facilitate the location of the set trunk and its further monitoring. Sites for the application of the ultrasonographic probe at each reference point have been indicated. In the case of the ulnar nerve, the dynamic component of the examination was emphasized. The text is illustrated with images of probe positioning, diagrams of the normal course of the nerves as well as a series of ultrasonographic pictures of normal nerves of the upper limb. This article aims to serve as a guide in the ultrasound examination of the peripheral nerves of the upper extremity. It should be remembered that a thorough knowledge of the area’s topographic anatomy is required for this type of examination.

  7. Peripheral Atherectomy: Applications and Techniques.

    Science.gov (United States)

    Mittleider, Derek; Russell, Erich

    2016-06-01

    Peripheral atherectomy is a class of procedures that is rapidly increasing in volume. Multiple classes of devices exist, and newer variants are added to the market annually. The devices see wide application for de novo lesions, in-stent restenosis, and adjunctive therapy for drug-coated balloons. The body of evidence supporting atherectomy is less robust than for many other peripheral therapies. The frequency and severity of complications from atherectomy can be significant compared with angioplasty and stenting, and familiarity with preventative and bailout techniques is essential for the interventionalist. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Imaging of a glioma using peripheral benzodiazepine receptor ligands

    Energy Technology Data Exchange (ETDEWEB)

    Starosta-Rubinstein, S.; Ciliax, B.J.; Penney, J.B.; McKeever, P.; Young, A.B.

    1987-02-01

    Two types of benzodiazepine receptors have been demonstrated in mammalian tissues, one which is localized on neuronal elements in brain and the other, on glial cells and in peripheral tissues such as kidney. In vivo administration of /sup 3/H-labeled PK 11195 (1-(2-chlorophenyl-N-methyl-N-(1-methylpropyl)-3-isoquinoline carboxamide) or (/sup 3/H)flunitrazepam with 5 mg of clonazepam per kg to rats with intracranial C6 gliomas resulted in high levels of tritiated-drug binding to the tumor as shown by quantitative autoradiography. Pharmacological studies indicated that the bound drugs labeled the peripheral benzodiazepine binding site. Binding to the peripheral benzodiazepine site was confirmed primarily to malignant cells with little binding to adjacent normal brain tissue or to necrotic tissue. Tumor cell binding was completely inhibited by preadministration of the peripheral benzodiazepine blocking agent PK 11195 at 5 mg/kg. The centrally selective benzodiazepine ligand clonazepam had no effect on PK 11195 binding to the tumor cells. When binding to other tumor cell lines grown in nude mice and nude athymic rats was evaluated, little or no peripheral benzodiazepine binding was detected on human pheochromocytoma (RN1) and neuroblastoma (SK-N-MC, SK-N-SH) tumor cells, respectively. However, high densities of peripheral benzodiazepine binding sites were observed on tumors derived from a human glioma cell line (ATCC HTB 14, U-87 MG). The presence of high concentrations of specific peripheral benzodiazepine receptors on glial tumors suggests that human primary central nervous system tumors could be imaged and diagnosed using peripheral benzodiazepine ligands labeled with positron- or gamma-emitting isotopes.

  9. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    Science.gov (United States)

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P phlebitis included pain (P phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  10. Peripheral ossifying fibroma of oral cavity: histopathologic differential diagnoses.

    Science.gov (United States)

    Shamim, Thorakkal

    2012-01-01

    Peripheral ossifying fibroma is a benign neoplasm that usuallydevelops from gingiva, presenting as an exophytic smooth surfaced pink or red nodular mass that is sessile or is less frequently seen on a pedicle. From the Indian perspective, it is usually noticed in 5th-6th decades of life with female predilection. Microscopically, the tumour shows stratified squamous epithelium and highly cellular fibrous stroma, sparse endothelial proliferation with fibroblasts and dystrophic calcifications. It has to be differentiated histopathologically from pyogenic granuloma, fibroma, peripheral giant cell granuloma, peripheral odontogenic fibroma and fibrous hyperplasia. A case of peripheral ossifying fibroma of maxillary gingiva in a 55-year-old Indian woman is reported.

  11. MRI features of tuberculosis of peripheral joints

    Energy Technology Data Exchange (ETDEWEB)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B. E-mail: gujralrb@sgpgi.ac.in

    2003-10-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis.

  12. MRI features of tuberculosis of peripheral joints

    International Nuclear Information System (INIS)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B.

    2003-01-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis

  13. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  14. Responses to the 1983 Expulsion of Aliens from Nigeria: A Critique

    African Journals Online (AJOL)

    First Lady

    greeted with a barrage of criticism by members of the international community .... exclusively business-oriented background and lack of intimacy with the intricacies ... bribery, corruption, inflation and profiteering gripped Ghanaians as workers'.

  15. Does formal mentoring for faculty members matter? A survey of clinical faculty members.

    Science.gov (United States)

    Mylona, Elza; Brubaker, Linda; Williams, Valerie N; Novielli, Karen D; Lyness, Jeffrey M; Pollart, Susan M; Dandar, Valerie; Bunton, Sarah A

    2016-06-01

    Mentoring relationships, for all medical school faculty members, are an important component of lifelong development and education, yet an understanding of mentoring among medical school clinical faculty members is incomplete. This study examined associations between formal mentoring relationships and aspects of faculty members' engagement and satisfaction. It then explored the variability of these associations across subgroups of clinical faculty members to understand the status of mentoring and outcomes of mentoring relationships. The authors hypothesised that academic clinical faculty members currently in formal mentoring relationships experience enhanced employee engagement and satisfaction with their department and institution. Medical school faculty members at 26 self-selected USA institutions participated in the 2011-2014 Faculty Forward Engagement Survey. Responses from clinical faculty members were analysed for relationships between mentoring status and perceptions of engagement by faculty members. Of the 11 953 clinical faculty respondents, almost one-third reported having a formal mentoring relationship (30%; 3529). Most mentored faculty indicated the relationship was important (86%; n = 3027), and over three-fourths were satisfied with their mentoring experience (77%; n = 2722). Mentored faculty members across ranks reported significantly higher levels of satisfaction and more positive perceptions of their roles in the organisation. Faculty members who were not receiving mentoring reported significantly less satisfaction with their workplace environment and lower overall satisfaction. Mentored clinical faculty members have significantly greater satisfaction with their department and institution. This multi-institutional study provides evidence that fostering mentoring opportunities may facilitate faculty members' satisfaction and engagement, which, in turn, may help medical schools retain high-quality faculty staff committed to the multidimensional

  16. Associations between peripheral vertigo and gastroesophageal reflux disease.

    Science.gov (United States)

    Viliušytė, Edita; Macaitytė, Raminta; Vaitkus, Antanas; Rastenytė, Daiva

    2015-09-01

    We hypothesize that peripheral vertigo is associated with gastroesophageal reflux disease (GERD). Two mechanisms could be considered – gastric acids may directly irritate the respiratory mucosa and cause inflammation, or Helicobacter pylori (H. pylori) could be present and cause local infection. Reflux material (Hydrochloric acid (HCl) and pepsin) could get into the middle ear via Eustachian tube and affect osseous structures directly. Disturbance of ossicles could cause tinnitus, which is more common for peripheral vertigo. H. pylori could also get in the esophagus and in the upper respiratory tract via gastroesophageal reflux, and could cause tympanosclerosis and fixation of ossicles. In our study group, 120 of 153 (78.4%) patients had gastroesophageal reflux disease (GERD). Diagnostic tests of H. pylori (rapid urease test or blood antibody test) were performed for 96 of 120 (80%) patients with GERD and were found positive for 32 of 96 (33.3%) patients. Peripheral vertigo was present in 93 of 120 (77.6%) patients with GERD compared to 33 of 126 (26%) patients without GERD (χ(2)=9.016, p=0.003). H. pylori and peripheral vertigo coexisted in 26 of 126 patients (20.6%) (OR 1.36; 95% CI 0.49-3.74, p=0.55). Our study demonstrated statistically significant association between peripheral vertigo and GERD but not between peripheral vertigo and H. pylori. Further more extensive investigations are needed in order to explore our hypothesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A Strain-Based Method to Detect Tires' Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development.

    Science.gov (United States)

    Yunta, Jorge; Garcia-Pozuelo, Daniel; Diaz, Vicente; Olatunbosun, Oluremi

    2018-02-06

    Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire's loss of grip and estimations of the lateral friction coefficient.

  18. Assessment of the presence/absence of the palmaris longus muscle in different sports, and elite and non-elite sport populations.

    Science.gov (United States)

    Fowlie, Craig; Fuller, Colin; Pratten, Margaret K

    2012-06-01

    To investigate whether higher presence of the palmaris longus muscle is associated with sports that require hand grip. Cross-sectional study. Six hundred and forty-two medical students, members of sports clubs and national athletes. Participants were invited to complete a questionnaire that assessed their main sport, elite or non-elite level of participation, and level of activity. The presence of the palmaris longus was assessed visually using a standardised test. Presence of the palmaris longus, type of hand grip required for the sport and the level of participation. The presence of the palmaris longus was higher in elite athletes (21/22, 96%) than non-elite athletes (66/84, 79%; P=0.066) for sports that require a dominant-handed or two-handed cylindrical grip (18/22, 82% and 19/35, 54%, respectively; P=0.034). For both elite and non-elite athletes, the presence of the palmaris longus was higher in those participating in sustained grip sports (325/387, 84%) compared with sports that do not require a sustained grip (150/197, 76%; P=0.012). The palmaris longus may provide an advantage in certain types of sport that require hand grip, and for elite athletes participating in sports that require a dominant-handed or two-handed cylindrical hand grip. Orthopaedic specialists considering the use of the palmaris longus for a grafting procedure on an athlete should consider the level of participation and the type of hand grip required in the athlete's sport. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  19. Peripheral Neuropathy: A Practical Approach to Diagnosis and Symptom Management.

    Science.gov (United States)

    Watson, James C; Dyck, P James B

    2015-07-01

    Peripheral neuropathy is one of the most prevalent neurologic conditions encountered by physicians of all specialties. Physicians are faced with 3 distinct challenges in caring for patients with peripheral neuropathy: (1) how to efficiently and effectively screen (in less than 2 minutes) an asymptomatic patient for peripheral neuropathy when they have a disorder in which peripheral neuropathy is highly prevalent (eg, diabetes mellitus), (2) how to clinically stratify patients presenting with symptoms of neuropathy to determine who would benefit from specialty consultation and what testing is appropriate for those who do not need consultation, and (3) how to treat the symptoms of painful peripheral neuropathy. In this concise review, we address these 3 common clinical scenarios. Easily defined clinical patterns of involvement are used to identify patients in need of neurologic consultation, the yield of laboratory and other diagnostic testing is reviewed for the evaluation of length-dependent, sensorimotor peripheral neuropathies (the most common form of neuropathy), and an algorithmic approach with dosing recommendations is provided for the treatment of neuropathic pain associated with peripheral neuropathy. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  20. Peripheral retinal nonperfusion associated with chronic myeloid leukemia.

    NARCIS (Netherlands)

    Nobacht, S.; Vandoninck, K.F.; Deutman, A.F.; Klevering, B.J.

    2003-01-01

    PURPOSE: To report a case of peripheral retinal nonperfusion and chronic myeloid leukemia in a 23-year-old woman. DESIGN: Observational case report. METHODS: A complete ophthalmic and systemic evaluation was performed. RESULTS: Ophthalmic examination revealed peripheral retinal nonperfusion with

  1. Malignant peripheral nerve sheath tumours in inherited disease

    Directory of Open Access Journals (Sweden)

    Evans D

    2012-10-01

    Full Text Available Abstract Background Malignant peripheral nerve sheath tumours (MPNST are rare tumours known to occur at high frequency in neurofibromatosis 1 (NF1, but may also occur in other cancer prone syndromes. Methods The North West Regional Genetic Register covers a population of 4.1 million and was interrogated for incidence of MPNST in 12 cancer prone syndromes. Age, incidence and survival curves were generated for NF1. Results Fifty two of 1254 NF1 patients developed MPNST, with MPNST also occurring in 2/181 cases of schwannomatosis and 2/895 NF2 patients. Three cases were also noted in TP53 mutation carriers. However, there were no cases amongst 5727BRCA1/2 carriers and first degree relatives, 2029 members from Lynch syndrome families, nor amongst 447 Familial Adenomatous Polyposis, 202 Gorlin syndrome, nor 87 vHL cases. Conclusion MPNST is associated with schwannomatosis and TP53 mutations and is confirmed at high frequency in NF1. It appears to be only increased in NF2 amongst those that have been irradiated. The lifetime risk of MPNST in NF1 is between 9–13%.

  2. The clinical identification of peripheral neuropathy among older persons.

    Science.gov (United States)

    Richardson, James K

    2002-11-01

    To identify simple clinical rules for the detection of a diffuse peripheral neuropathy among older outpatients. Observational, blinded, controlled study. A tertiary-care electrodiagnostic laboratory and biomechanics laboratory. One hundred research subjects, 68 with electrodiagnostic evidence of peripheral neuropathy, between the ages of 50 and 80 years. Not applicable. One examiner, unaware of the results of electrodiagnostic testing, evaluated Achilles' and patellar reflexes, Romberg testing, semiquantified vibration, and position sense at the toe and ankle in all subjects, and unipedal stance time and the Michigan Diabetes Neuropathy Score in a subset of subjects. Significant group differences were present in all clinical measures tested. Three signs, Achilles' reflex (absent despite facilitation), vibration (128Hz tuning fork perceived for <10s), and position sense (<8/10 1-cm trials) at the toe, were the best predictors of peripheral neuropathy on both univariate and logistic regression (pseudo R(2)=.744) analyses. The presence of 2 or 3 signs versus 0 or 1 sign identified peripheral neuropathy with sensitivity, specificity, and positive and negative predictive values of 94.1%, 84.4%, 92.8%, and 87.1%, respectively. Values were similar among subgroups of subjects with and without diabetes mellitus. When other clinicians applied the technique to 12 more subjects, excellent interrater reliability regarding the presence of peripheral neuropathy (kappa=.833) and good to excellent interrater reliability for each sign (kappa range,.667-1.00) were shown. Among older persons, the presence of 2 or 3 of the 3 clinical signs strongly suggested electrodiagnostic evidence of a peripheral neuropathy, regardless of etiology. Age-related decline in peripheral nerve function need not be a barrier to the clinical recognition of a diffuse peripheral neuropathy among older persons. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of

  3. The Role of Cholecystokinin in Peripheral Taste Signaling in Mice

    Directory of Open Access Journals (Sweden)

    Ryusuke Yoshida

    2017-10-01

    Full Text Available Cholecystokinin (CCK is a gut hormone released from enteroendocrine cells. CCK functions as an anorexigenic factor by acting on CCK receptors expressed on the vagal afferent nerve and hypothalamus with a synergistic interaction between leptin. In the gut, tastants such as amino acids and bitter compounds stimulate CCK release from enteroendocrine cells via activation of taste transduction pathways. CCK is also expressed in taste buds, suggesting potential roles of CCK in taste signaling in the peripheral taste organ. In the present study, we focused on the function of CCK in the initial responses to taste stimulation. CCK was coexpressed with type II taste cell markers such as Gα-gustducin, phospholipase Cβ2, and transient receptor potential channel M5. Furthermore, a small subset (~30% of CCK-expressing taste cells expressed a sweet/umami taste receptor component, taste receptor type 1 member 3, in taste buds. Because type II taste cells are sweet, umami or bitter taste cells, the majority of CCK-expressing taste cells may be bitter taste cells. CCK-A and -B receptors were expressed in both taste cells and gustatory neurons. CCK receptor knockout mice showed reduced neural responses to bitter compounds compared with wild-type mice. Consistently, intravenous injection of CCK-Ar antagonist lorglumide selectively suppressed gustatory nerve responses to bitter compounds. Intravenous injection of CCK-8 transiently increased gustatory nerve activities in a dose-dependent manner whereas administration of CCK-8 did not affect activities of bitter-sensitive taste cells. Collectively, CCK may be a functionally important neurotransmitter or neuromodulator to activate bitter nerve fibers in peripheral taste tissues.

  4. Peripheral neuropathy of dietary riboflavin deficiency in racing pigeons.

    Science.gov (United States)

    Wada, Y; Kondo, H; Itakura, C

    1996-02-01

    An occurrence of peripheral neuropathy in nine 14- to 55-day-old racing pigeons was documented. The predominant clinical signs were diarrhea, and leg and wing paralysis. Grossly, there was discoloration and swelling of all the peripheral nerve trunks. Microscopic lesions comprising swelling, fragmentation and demyelination of myelin sheaths, and proliferation of Schwann cells, were seen in the peripheral nerves of all birds examined. These changes were associated with moderate to severe swelling, fragmentation, atrophy and loss of axons. The peripheral nerve lesions in these cases were similar to those of dietary riboflavin deficiency in chickens. An analysis of the diet given to the pigeons indicated that the riboflavin concentration was only 0.9 mg/kg feed.

  5. Malignant Peripheral Nerve Sheath Tumour of the Maxilla

    Directory of Open Access Journals (Sweden)

    Puja Sahai

    2014-01-01

    Full Text Available A 38-year-old man was diagnosed with malignant peripheral nerve sheath tumour of the maxilla. He was treated with total maxillectomy. Histopathological examination of the resected specimen revealed a close resection margin. The tumour was of high grade with an MIB-1 labelling index of almost 60%. At six weeks following the surgery, he developed local tumour relapse. The patient succumbed to the disease at five months from the time of diagnosis. The present report underlines the locally aggressive nature of malignant peripheral nerve sheath tumour of the maxilla which necessitates an early therapeutic intervention. A complete resection with clear margins is the most important prognostic factor for malignant peripheral nerve sheath tumour in the head and neck region. Adjuvant radiotherapy may be considered to improve the local control. Future research may demarcate the role of targeted therapy for patients with malignant peripheral nerve sheath tumour.

  6. The mRNA level of MLH1 in peripheral blood is a biomarker for the diagnosis of hereditary nonpolyposis colorectal cancer.

    Science.gov (United States)

    Yu, Hong; Li, Hui; Cui, Yongan; Xiao, Wei; Dai, Guihong; Huang, Junxing; Wang, Chaofu

    2016-01-01

    Hereditary nonpolyposis colorectal cancer (HNPCC) is caused by functional defects in mismatch repair (MMR) genes, including mutL homolog 1 (MLH1) and mutS homolog 2 (MSH2). This study aimed to assess whether the mRNA expression of MLH1 in peripheral blood could be used as a biomarkers for the diagnosis of HNPCC. The mRNA level of MLH1 was determined in 19 HNPCC families (46 members) using real-time quantitative polymerase chain reaction (qPCR). The mRNA levels of MLH1 in HNPCC were significantly lower than controls (P MLH1 for the diagnosis of HNPCC with the area under curve of 0.858. At an optimal cut-off value (0.511), the mRNA level of MLH1 had a sensitivity of 81.3% and a specificity of 86.7% for distinguishing HNPCC from controls. In conclusion, the mRNA expression of MLH1 in peripheral blood may serve as a biomarker for the diagnosis of HNPCC.

  7. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    Energy Technology Data Exchange (ETDEWEB)

    Çakır, Volkan; Çakır, Dilek [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Pişkin, Mehmet [Department of Food Technology, Çanakkale Vocational School of Technical Sciences, Çanakkale Onsekiz Mart University, 17100 Çanakkale (Turkey); Durmuş, Mahmut [Gebze Institute of Technology, Department of Chemistry, PO Box 141, Gebze 41400, Kocaeli (Turkey); Bıyıklıoğlu, Zekeriya, E-mail: zekeriya_61@yahoo.com [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2014-10-15

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, {sup 1}H-NMR, {sup 13}C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed.

  8. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    International Nuclear Information System (INIS)

    Çakır, Volkan; Çakır, Dilek; Pişkin, Mehmet; Durmuş, Mahmut; Bıyıklıoğlu, Zekeriya

    2014-01-01

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, 1 H-NMR, 13 C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed

  9. Demographic processes of developmentally peripheral areas in Hungary

    Directory of Open Access Journals (Sweden)

    Pénzes János

    2015-01-01

    Full Text Available The current study investigates the demographic processes and challenges of the Hungarian developmentally peripheral settlements. Demographic challenges can be regarded as important consequences of the social and economic disadvantages in spatial terms. However, the interrelating negative demographic tendencies cause even more backward situation blocking or hindering the development. The objective of the current analysis is to discover the demographic characteristics of the peripheral settlements, to detect the spatial disparities and to point out the correlation between backwardness and the investigated demographic phenomena with the help of the census databases 1980-2011 and local datasets on Roma population. Using methods of multivariate statistical analysis, seven indicators were selected in order to achieve the goals of the paper. Backward areas are primarily characterized by population decrease with significant disparities, but there were growing communities among them as well. Some small villages in Northern and Southwestern Hungary will foreseeably face complete depopulation within few years. Primarily small sized villages faced intense decrease in rate of natural change, but dynamic population growth was also detected. Migration loss tends to correlate with the extent of peripherality, as increasing values of migration balance accompany decreasing ratio of peripheral settlements in the area. The ratio of elderly population shows an expressively two-faced character, with the extremely aging and very juvenile settlements. The ratios of Roma population reflect the scale of peripherality. Extended ethnic change could be predicted in Northeastern and Southwestern Hungary and near the Middle Tisza valley. Presented demographic processes will make the backwardness of most of the peripheral settlements stable.

  10. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    OpenAIRE

    O. G. Pozdeyeva; T. B. Shaimov; A. Yu. Galin; R. B. Shaimov; T. A. Shaimova; A. V. Zolotova; A. V. Fomin

    2014-01-01

    Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes) with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of op...

  11. Clinical impact of exercise in patients with peripheral arterial disease.

    Science.gov (United States)

    Novakovic, Marko; Jug, Borut; Lenasi, Helena

    2017-08-01

    Increasing prevalence, high morbidity and mortality, and decreased health-related quality of life are hallmarks of peripheral arterial disease. About one-third of peripheral arterial disease patients have intermittent claudication with deleterious effects on everyday activities, such as walking. Exercise training improves peripheral arterial disease symptoms and is recommended as first line therapy for peripheral arterial disease. This review examines the effects of exercise training beyond improvements in walking distance, namely on vascular function, parameters of inflammation, activated hemostasis and oxidative stress, and quality of life. Exercise training not only increases walking distance and physiologic parameters in patients with peripheral arterial disease, but also improves the cardiovascular risk profile by helping patients achieve better control of hypertension, hyperglycemia, obesity and dyslipidemia, thus further reducing cardiovascular risk and the prevalence of coexistent atherosclerotic diseases. American guidelines suggest supervised exercise training, performed for a minimum of 30-45 min, at least three times per week, for at least 12 weeks. Walking is the most studied exercise modality and its efficacy in improving cardiovascular parameters in patients with peripheral arterial disease has been extensively proven. As studies have shown that supervised exercise training improves walking performance, cardiovascular parameters and quality of life in patients with peripheral arterial disease, it should be encouraged and more often prescribed.

  12. SP140L, an Evolutionarily Recent Member of the SP100 Family, Is an Autoantigen in Primary Biliary Cirrhosis

    Directory of Open Access Journals (Sweden)

    Mario Saare

    2015-01-01

    Full Text Available The SP100 family members comprise a set of closely related genes on chromosome 2q37.1. The widely expressed SP100 and the leukocyte-specific proteins SP110 and SP140 have been associated with transcriptional regulation and various human diseases. Here, we have characterized the SP100 family member SP140L. The genome sequence analysis showed the formation of SP140L gene through rearrangements of the two neighboring genes, SP100 and SP140, during the evolution of higher primates. The SP140L expression is interferon-inducible with high transcript levels in B cells and other peripheral blood mononuclear cells. Subcellularly, SP140L colocalizes with SP100 and SP140 in nuclear structures that are devoid of SP110, PML, or p300 proteins. Similarly to SP100 and SP140 protein, we detected serum autoantibodies to SP140L in patients with primary biliary cirrhosis using luciferase immunoprecipitation system and immunoblotting assays. In conclusion, our results show that SP140L is phylogenetically recent member of SP100 proteins and acts as an autoantigen in primary biliary cirrhosis patients.

  13. Systematic identification and validation of candidate genes for detection of circulating tumor cells in peripheral blood specimens of colorectal cancer patients.

    Science.gov (United States)

    Findeisen, Peter; Röckel, Matthias; Nees, Matthias; Röder, Christian; Kienle, Peter; Von Knebel Doeberitz, Magnus; Kalthoff, Holger; Neumaier, Michael

    2008-11-01

    The presence of tumor cells in peripheral blood is being regarded increasingly as a clinically relevant prognostic factor for colorectal cancer patients. Current molecular methods are very sensitive but due to low specificity their diagnostic value is limited. This study was undertaken in order to systematically identify and validate new colorectal cancer (CRC) marker genes for improved detection of minimal residual disease in peripheral blood mononuclear cells of colorectal cancer patients. Marker genes with upregulated gene expression in colorectal cancer tissue and cell lines were identified using microarray experiments and publicly available gene expression data. A systematic iterative approach was used to reduce a set of 346 candidate genes, reportedly associated with CRC to a selection of candidate genes that were then further validated by relative quantitative real-time RT-PCR. Analytical sensitivity of RT-PCR assays was determined by spiking experiments with CRC cells. Diagnostic sensitivity as well as specificity was tested on a control group consisting of 18 CRC patients compared to 12 individuals without malignant disease. From a total of 346-screened genes only serine (or cysteine) proteinase inhibitor, clade B (ovalbumin), member 5 (SERPINB5) showed significantly elevated transcript levels in peripheral venous blood specimens of tumor patients when compared to the nonmalignant control group. These results were confirmed by analysis of an enlarged collective consisting of 63 CRC patients and 36 control individuals without malignant disease. In conclusion SERPINB5 seems to be a promising marker for detection of circulating tumor cells in peripheral blood of colorectal cancer patients.

  14. Peripheral Arterial Disease Study (PERART: Prevalence and predictive values of asymptomatic peripheral arterial occlusive disease related to cardiovascular morbidity and mortality

    Directory of Open Access Journals (Sweden)

    Bundó Magda

    2007-12-01

    Full Text Available Abstract Background The early diagnosis of atherosclerotic disease is essential for developing preventive strategies in populations at high risk and acting when the disease is still asymptomatic. A low ankle-arm index (AAI is a good marker of vascular events and may be diminished without presenting symptomatology (silent peripheral arterial disease. The aim of the PERART study (PERipheral ARTerial disease is to determine the prevalence of peripheral arterial disease (both silent and symptomatic in a general population of both sexes and determine its predictive value related to morbimortality (cohort study. Methods/Design This cross-over, cohort study consists of 2 phases: firstly a descriptive, transversal cross-over study to determine the prevalence of peripheral arterial disease, and secondly, a cohort study to evaluate the predictive value of AAI in relation to cardiovascular morbimortality. From September 2006 to June 2007, a total of 3,010 patients over the age of 50 years will be randomly selected from a population adscribed to 24 healthcare centres in the province of Barcelona (Spain. The diagnostic criteria of peripheral arterial disease will be considered as an AAI Discussion In this study we hope to determine the prevalence of peripheral arterial disease, especially the silent forms, in the general population and establish its relationship with cardiovascular morbimortality. A low AAI may be a better marker of arterial disease than the classical cardiovascular risk factors and may, therefore, contribute to improving the predictive value of the equations of cardiovascular risk and thereby allowing optimisation of multifactorial treatment of atherosclerotic disease.

  15. Consequences of peripheral frequency selectivity for nonsimultaneous masking

    NARCIS (Netherlands)

    Duifhuis, H.

    1973-01-01

    The frequency selectivity of the peripheral ear (e.g., at the VIIIth nerve level) is so acute that onset and offset transients in responses to short signals produce a nonnegligible extension of the signal duration. Thus, peripheral excitation patterns produced by signals which were separated in time

  16. Atherectomy in Peripheral Artery Disease: A Review.

    Science.gov (United States)

    Bhat, Tariq M; Afari, Maxwell E; Garcia, Lawrence A

    2017-04-01

    Peripheral arterial disease (PAD) is a clinical manifestation of systemic atherosclerosis and is associated with significant morbidity and mortality. The physiological force and shear stress from angioplasty and stenting have made PAD treatment challenging. Atherectomy devices have continued to emerge as a major therapy in the management of peripheral vascular disease. This article presents a review of the current literature for the atherectomy devices used in PAD.

  17. Detecting peripheral-based attacks on the host memory

    CERN Document Server

    Stewin, Patrick

    2015-01-01

    This work addresses stealthy peripheral-based attacks on host computers and presents a new approach to detecting them. Peripherals can be regarded as separate systems that have a dedicated processor and dedicated runtime memory to handle their tasks. The book addresses the problem that peripherals generally communicate with the host via the host’s main memory, storing cryptographic keys, passwords, opened files and other sensitive data in the process – an aspect attackers are quick to exploit.  Here, stealthy malicious software based on isolated micro-controllers is implemented to conduct an attack analysis, the results of which provide the basis for developing a novel runtime detector. The detector reveals stealthy peripheral-based attacks on the host’s main memory by exploiting certain hardware properties, while a permanent and resource-efficient measurement strategy ensures that the detector is also capable of detecting transient attacks, which can otherwise succeed when the applied strategy only me...

  18. Intravenous Lidocaine Infusion to Treat Chemotherapy-Induced Peripheral Neuropathy.

    Science.gov (United States)

    Papapetrou, Peter; Kumar, Aashish J; Muppuri, Rudram; Chakrabortty, Shushovan

    2015-11-01

    Chemotherapy-induced peripheral neuropathy is a debilitating side effect of chemotherapy, which manifests as paresthesias, dysesthesias, and numbness in the hands and feet. Numerous chemoprotective agents and treatments have been used with limited success to treat chemotherapy-induced peripheral neuropathy. We report a case in which a patient presenting with chemotherapy-induced peripheral neuropathy received an IV lidocaine infusion over the course of 60 minutes with complete symptomatic pain relief for a prolonged period of 2 weeks.

  19. Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma

    International Nuclear Information System (INIS)

    Woo, Seong Ku; Suh, Soo Jhi; Kim, Ho Joon; Chun, Byung Hee

    1986-01-01

    Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 cases and needle biopsy in 2 case. 4. Laboratory findings were not specific, but there were only 2 cases with elevated alpha-fetoprotein level. 5. Associated diseases were gallstones in 1 case, intrahepatic duct stones in 1 case, extrahepatic duct stones in 2 cases, acute or chronic cholecystitis in 5 cases and CS in 3 cases. 6. Angiographic and scintigraphic findings were helpful in differential diagnosis from hepatoma but ultrasonography was non-specific. 7. The number of tumor were solitary in 12 cases and multiple in 2 cases. Among solitary cases, the site of involvement of the liver were right lobe in 8 cases and left lobe in 4 cases. 8. Common CT features of the intrahepatic peripheral cholangiocinoma of the liver were irregular, inhomogeneous, occasionally peripherally enhancing, low density liver mass, frequently accompanied by diffuse or segmental dilatation of the intrahepatic bile duct. If there were normal alpha fetoprotein level, positive skin and/or stool examination for CS and diffuse or segmental dilatation of the intrahepatic duct

  20. Diabetes and obesity are the main metabolic drivers of peripheral neuropathy.

    Science.gov (United States)

    Callaghan, Brian C; Gao, LeiLi; Li, Yufeng; Zhou, Xianghai; Reynolds, Evan; Banerjee, Mousumi; Pop-Busui, Rodica; Feldman, Eva L; Ji, Linong

    2018-04-01

    To determine the associations between individual metabolic syndrome (MetS) components and peripheral neuropathy in a large population-based cohort from Pinggu, China. A cross-sectional, randomly selected, population-based survey of participants from Pinggu, China was performed. Metabolic phenotyping and neuropathy outcomes were performed by trained personnel. Glycemic status was defined according to the American Diabetes Association criteria, and the MetS using modified consensus criteria (body mass index instead of waist circumference). The primary peripheral neuropathy outcome was the Michigan Neuropathy Screening Instrument (MNSI) examination. Secondary outcomes were the MNSI questionnaire and monofilament testing. Multivariable models were used to assess for associations between individual MetS components and peripheral neuropathy. Tree-based methods were used to construct a classifier for peripheral neuropathy using demographics and MetS components. The mean (SD) age of the 4002 participants was 51.6 (11.8) and 51.0% were male; 37.2% of the population had normoglycemia, 44.0% prediabetes, and 18.9% diabetes. The prevalence of peripheral neuropathy increased with worsening glycemic status (3.25% in normoglycemia, 6.29% in prediabetes, and 15.12% in diabetes, P peripheral neuropathy. Age, diabetes, and weight were the primary splitters in the classification tree for peripheral neuropathy. Similar to previous studies, diabetes and obesity are the main metabolic drivers of peripheral neuropathy. The consistency of these results reinforces the urgent need for effective interventions that target these metabolic factors to prevent and/or treat peripheral neuropathy.

  1. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  2. Carvedilol prevents functional deficits in peripheral nerve mitochondria of rats with oxaliplatin-evoked painful peripheral neuropathy

    International Nuclear Information System (INIS)

    Areti, Aparna; Komirishetty, Prashanth; Kumar, Ashutosh

    2017-01-01

    Oxaliplatin use as chemotherapeutic agent is frequently limited by cumulative neurotoxicity which may compromise quality of life. Reports relate this neurotoxic effect to oxidative stress and mitochondrial dysfunction in peripheral nerves and dorsal root ganglion (DRG). Carvedilol is an antihypertensive drug, has also been appreciated for its antioxidant and mitoprotective properties. Carvedilol co-treatment did not reduce the anti-tumor effects of oxaliplatin in human colon cancer cells (HT-29), but exhibited free radical scavenging activity against oxaliplatin-induced oxidative stress in neuronal cells (Neuro-2a). Hence, the present study was designed to investigate the effect of carvedilol in the experimental model of oxaliplatin-induced peripheral neuropathy (OIPN) in Sprague-Dawley rats. Oxaliplatin reduced the sensory nerve conduction velocity and produced the thermal and mechanical nociception. Carvedilol significantly (P < 0.001) attenuated these functional and sensorimotor deficits. It also counteracted oxidative/nitrosative stress by reducing the levels of nitrotyrosine and improving the mitochondrial superoxide dismutase expression in both sciatic nerve and DRG tissues. It improved the mitochondrial function and prevented the oxaliplatin-induced alteration in mitochondrial membrane potential in sciatic nerve thus prevented loss of intra epidermal nerve fiber density in the foot pads. Together the results prompt the use of carvedilol along with chemotherapy with oxaliplatin to prevent the peripheral neuropathy. - Graphical abstract: Schematic representation neuroprotective mechanisms of carvedilol in oxaliplatin-induced peripheral neuropathy. - Highlights: • Oxaliplatin-induced mitochondrial dysfunction causes neurotoxicity. • Mitochondrial dysfunction leads to bioenergetic and functional deficits. • Carvedilol alleviated oxaliplatin-induced behavioural and functional changes. • Targeting mitochondria with carvedilol attenuated neuropathic pain.

  3. Carvedilol prevents functional deficits in peripheral nerve mitochondria of rats with oxaliplatin-evoked painful peripheral neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Areti, Aparna; Komirishetty, Prashanth; Kumar, Ashutosh, E-mail: ashutosh.niperhyd@gov.in

    2017-05-01

    Oxaliplatin use as chemotherapeutic agent is frequently limited by cumulative neurotoxicity which may compromise quality of life. Reports relate this neurotoxic effect to oxidative stress and mitochondrial dysfunction in peripheral nerves and dorsal root ganglion (DRG). Carvedilol is an antihypertensive drug, has also been appreciated for its antioxidant and mitoprotective properties. Carvedilol co-treatment did not reduce the anti-tumor effects of oxaliplatin in human colon cancer cells (HT-29), but exhibited free radical scavenging activity against oxaliplatin-induced oxidative stress in neuronal cells (Neuro-2a). Hence, the present study was designed to investigate the effect of carvedilol in the experimental model of oxaliplatin-induced peripheral neuropathy (OIPN) in Sprague-Dawley rats. Oxaliplatin reduced the sensory nerve conduction velocity and produced the thermal and mechanical nociception. Carvedilol significantly (P < 0.001) attenuated these functional and sensorimotor deficits. It also counteracted oxidative/nitrosative stress by reducing the levels of nitrotyrosine and improving the mitochondrial superoxide dismutase expression in both sciatic nerve and DRG tissues. It improved the mitochondrial function and prevented the oxaliplatin-induced alteration in mitochondrial membrane potential in sciatic nerve thus prevented loss of intra epidermal nerve fiber density in the foot pads. Together the results prompt the use of carvedilol along with chemotherapy with oxaliplatin to prevent the peripheral neuropathy. - Graphical abstract: Schematic representation neuroprotective mechanisms of carvedilol in oxaliplatin-induced peripheral neuropathy. - Highlights: • Oxaliplatin-induced mitochondrial dysfunction causes neurotoxicity. • Mitochondrial dysfunction leads to bioenergetic and functional deficits. • Carvedilol alleviated oxaliplatin-induced behavioural and functional changes. • Targeting mitochondria with carvedilol attenuated neuropathic pain.

  4. Rag Deletion in Peripheral T Cells Blocks TCR Revision

    Science.gov (United States)

    Hale, J. Scott; Ames, Kristina T.; Boursalian, Tamar E.; Fink, Pamela J.

    2010-01-01

    Mature CD4+Vβ5+ T cells that recognize a peripherally expressed endogenous superantigen are tolerized either by deletion or T cell receptor (TCR) revision. In Vβ5 transgenic mice, this latter tolerance pathway results in the appearance of CD4+Vβ5−TCRβ+ T cells, coinciding with Rag1, Rag2, and TdT expression and the accumulation of Vβ-DJβ recombination intermediates in peripheral CD4+ T cells. Because post-thymic RAG-dependent TCR rearrangement has remained controversial, we sought to definitively determine whether TCR revision is an extrathymic process that occurs in mature peripheral T cells. We now show that Rag deletion in post-positive selection T cells in Vβ5 transgenic mice blocks TCR revision in vivo, and that mature peripheral T cells sorted to remove cells bearing endogenous TCRβ chains can express newly generated TCRβ molecules in adoptive hosts. These findings unambiguously demonstrate post-thymic, RAG-dependent TCR rearrangement and define TCR revision as a tolerance pathway that targets mature peripheral CD4+ T cells. PMID:20435935

  5. Paradoxical role of an Egr transcription factor family member, Egr2/Krox20, in learning and memory

    Directory of Open Access Journals (Sweden)

    Roseline Poirier

    2007-12-01

    Full Text Available It is well established that Egr1/zif268, a member of the Egr family of transcription factors, is critical for the consolidation of several forms of memories. Recently, the Egr3 family member has also been implicated in learning and memory. Because Egr family members encode closely related zinc-finger transcription factors sharing a highly homologous DNA binding domain that recognises the same DNA sequence, they may have related functions in brain. Another Egr family member expressed in brain, Egr2/Krox20 is known to be crucial for normal hindbrain development and has been implicated in several inherited peripheral neuropathies; however, due to Egr2-null mice perinatal lethality, its potential role in cognitive functions in the adult has not been yet explored. Here, we generated Egr2 conditional mutant mice allowing postnatal, forebrain-specific Cre-mediated Egr2 excision and tested homozygous, heterozygous and control littermates on a battery of behavioural tasks to evaluate motor capacity, exploratory behaviour, emotional reactivity and learning and memory performance in spatial and non-spatial tasks. Egr2-deficient mice had no sign of locomotor, exploratory or anxiety disturbances. Surprisingly, they also had no impairment in spatial learning and memory, taste aversion memory or fear memory using a trace conditioning paradigm. On the contrary, Egr2-deficient mice had improved performance in motor learning on a rotarod, and in object recognition memory. These results clearly do not extend the phenotypic consequences resulting from either Egr1 or Egr3 loss-of-function to Egr2. In contrast, they indicate that Egr family members may have different, and in certain circumstances antagonistic functions in the adult brain.

  6. Chemotherapy-induced peripheral neuropathy: an update on the current understanding.

    Science.gov (United States)

    Addington, James; Freimer, Miriam

    2016-01-01

    Chemotherapy-induced peripheral neuropathy is a common side effect of selected chemotherapeutic agents. Previous work has suggested that patients often under report the symptoms of chemotherapy-induced peripheral neuropathy and physicians fail to recognize the presence of such symptoms in a timely fashion. The precise pathophysiology that underlies chemotherapy-induced peripheral neuropathy, in both the acute and the chronic phase, remains complex and appears to be medication specific. Recent work has begun to demonstrate and further clarify potential pathophysiological processes that predispose and, ultimately, lead to the development of chemotherapy-induced peripheral neuropathy. There is increasing evidence that the pathway to neuropathy varies with each agent. With a clearer understanding of how these agents affect the peripheral nervous system, more targeted treatments can be developed in order to optimize treatment and prevent long-term side effects.

  7. Liposomes to target peripheral neurons and Schwann cells.

    Directory of Open Access Journals (Sweden)

    Sooyeon Lee

    Full Text Available While a wealth of literature for tissue-specific liposomes is emerging, optimal formulations to target the cells of the peripheral nervous system (PNS are lacking. In this study, we asked whether a novel formulation of phospholipid-based liposomes could be optimized for preferential uptake by microvascular endothelia, peripheral neurons and Schwann cells. Here, we report a unique formulation consisting of a phospholipid, a polymer surfactant and cholesterol that result in enhanced uptake by targeted cells. Using fluorescently labeled liposomes, we followed particle internalization and trafficking through a distinct route from dextran and escape from degradative compartments, such as lysosomes. In cultures of non-myelinating Schwann cells, liposomes associate with the lipid raft marker Cholera toxin, and their internalization is inhibited by disruption of lipid rafts or actin polymerization. In contrast, pharmacological inhibition of clathrin-mediated endocytosis does not significantly impact liposome entry. To evaluate the efficacy of liposome targeting in tissues, we utilized myelinating explant cultures of dorsal root ganglia and isolated diaphragm preparations, both of which contain peripheral neurons and myelinating Schwann cells. In these models, we detected preferential liposome uptake into neurons and glial cells in comparison to surrounding muscle tissue. Furthermore, in vivo liposome administration by intramuscular or intravenous injection confirmed that the particles were delivered to myelinated peripheral nerves. Within the CNS, we detected the liposomes in choroid epithelium, but not in myelinated white matter regions or in brain parenchyma. The described nanoparticles represent a novel neurophilic delivery vehicle for targeting small therapeutic compounds, biological molecules, or imaging reagents into peripheral neurons and Schwann cells, and provide a major advancement toward developing effective therapies for peripheral

  8. Peripheral phlebitis: a point-prevalence study.

    Science.gov (United States)

    Washington, Georgita T; Barrett, Robin

    2012-01-01

    The purpose of this research study was to determine the factors influencing peripheral phlebitis in the adult medical-surgical population. The authors would then be able to use those data to determine whether a change in practice was warranted. Data collection and analysis of 188 intravenous sites revealed that females with higher doses of medications in intravenous sites of longer dwell times and suboptimal nutrition were at greater risk of developing peripheral phlebitis. The point prevalence was greater than the recommended 5%, which led the authors to review their facility's patient care and documentation practices.

  9. [Degenerative lesions of the peripheral retina].

    Science.gov (United States)

    Conart, J-B; Baron, D; Berrod, J-P

    2014-01-01

    Degenerative lesions of the peripheral retina are present from teenage years onwards and increase with age. These abnormabilities are frequent, some of them being benign while others predispose to retinal tears and detachment. In the latter case, the lesions are rhegmatogenous and may justify prophylactic treatment by laser photocoagulation. We distinguish congenital lesions of the peripheral retina and intraretinal, chorioretinal and vitreoretinal degenerations. The holes and tears observed in 2% of the population consist of round atrophic holes, "horseshoe" tears, oral dialyses and giant tears. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  10. Engine piston assembly and forged piston member therefor having a cooling recess

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, B.C.; Erickson, K.L.; Green, J.A.; Nyez, D.S.

    1989-09-19

    This patent describes a forged steel piston member for reciprocating movement in an engine. It comprises: an upper portion of substantially cylindrical shape and having a central axis, a top surface, a tubular wall depending from the top surface and having a peripheral groove adapted to receive a sealing ring, a lower end surface, and an inwardly facing wall surface extending upwardly from the lower end surface. The upper portion further includes an outwardly facing wall surface spaced radially inwardly from the inwardly facing wall surface and a downwardly facing transition portion blendingly associated with the inwardly and outwardly facing wall surfaces to collectively define an annular cooling recess, the transition portion being elevational spaced a relatively short distance from the top surface; and the inwardly facing wall surface being a machined surface of revolution about the central axis integral or one-piece forging.

  11. F wave index: A diagnostic tool for peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    G R Sathya

    2017-01-01

    Interpretation & conclusions: Our results showed that F wave index in upper limb was significantly lower in patients with peripheral neuropathy than the healthy controls, and could be used for early detection of peripheral neuropathy.

  12. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  13. Enhancement characteristics of benign and malignant focal peripheral nodules in the peripheral zone of the prostate gland studied using contrast-enhanced transrectal ultrasound

    International Nuclear Information System (INIS)

    Tang, J.; Yang, J.-C.; Luo, Y.; Li, J.; Li, Y.; Shi, H.

    2008-01-01

    Aim: To assess the value of contrast-enhanced grey-scale transrectal ultrasound (CETRUS) in predicting the nature of peripheral zone hypoechoic lesions of the prostate. Materials and Methods: Ninety-one patients with peripheral zone hypoechoic lesions on ultrasound were evaluated with CETRUS followed by lesion-specific and sextant transrectal ultrasound-guided biopsies. The enhancement patterns of the lesions were observed and graded subjectively using adjacent peripheral zone tissue as the reference. Time to enhancement (AT), time to peak intensity (TTP) and peak intensity (PI) were quantified within each nodule. Ultrasound findings were correlated with biopsy findings. Results: Transrectal ultrasound-guided biopsy of the hypoechoic lesions revealed prostate cancer in 44 patients and benign prostatic diseases in 47. The intensity of enhancement within the lesions were graded as no enhancement, increased, equal, or decreased compared with adjacent peripheral zone tissue in two, 30, five and seven in the prostate cancer group and 14, 15, four and 14 in the benign group, respectively. The difference was statistically significant (p < 0.05). The peak enhancement intensity was found to be the most optimal discriminatory parameter (area under curve AUC 0.70; 95% CI: 0.58, 0.82). Conclusion: Malignant hypoechoic nodules in the peripheral zone of the prostate are more likely to enhance early and more intensely on CETRUS. A non-enhanced hypoechoic peripheral zone lesion was more likely to be benign

  14. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy

    Science.gov (United States)

    Kramer, Rita; Bielawski, Jacek; Kistner-Griffin, Emily; Othman, Alaa; Alecu, Irina; Ernst, Daniela; Kornhauser, Drew; Hornemann, Thorsten; Spassieva, Stefka

    2015-01-01

    Peripheral neuropathy is a major dose-limiting side effect of paclitaxel and cisplatin chemotherapy. In the current study, we tested the involvement of a novel class of neurotoxic sphingolipids, the 1-deoxysphingolipids. 1-Deoxysphingolipids are produced when the enzyme serine palmitoyltransferase uses l-alanine instead of l-serine as its amino acid substrate. We tested whether treatment of cells with paclitaxel (250 nM, 1 µM) and cisplatin (250 nM, 1 µM) would result in elevated cellular levels of 1-deoxysphingolipids. Our results revealed that paclitaxel, but not cisplatin treatment, caused a dose-dependent elevation of 1-deoxysphingolipids levels and an increase in the message and activity of serine palmitoyltransferase (P peripheral neuropathy symptoms [evaluated by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-chemotherapy-induced peripheral neuropathy-20 (CIPN20) instrument] and the 1-deoxysphingolipid plasma levels (measured by mass spectrometry) in 27 patients with breast cancer who were treated with paclitaxel chemotherapy. Our results showed that there was an association between the incidence and severity of neuropathy and the levels of very-long-chain 1-deoxyceramides such as C24 (P neuropathy (P peripheral neuropathy.—Kramer, R., Bielawski, J., Kistner-Griffin, E., Othman, A., Alecu, I., Ernst, D., Kornhauser, D., Hornemann, T., Spassieva, S. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy. PMID:26198449

  15. A dinamometria manual e seu uso na avaliação nutricional Hand grip strength test and its use in nutritional assessment

    Directory of Open Access Journals (Sweden)

    Michael Maia Schlüssel

    2008-04-01

    Full Text Available Esta revisão de literatura aborda aspectos metodológicos e fisiológicos da dinamometria manual. A dinamometria manual é um teste funcional do músculo esquelético que vem recebendo uma crescente atenção de clínicos e pesquisadores da área de saúde nos últimos anos. Recentemente, tem merecido atenção como indicador do estado nutricional, particularmente para pacientes internados. Dentre os principais fatores que influenciam esta medida, destacam-se o sexo, a idade, a estatura, a massa corporal e a mão dominante dos indivíduos. Os resultados desta revisão demonstram ainda que diversos outros fatores, relacionados ao protocolo de aferição, como a posição do indivíduo, o tipo de instrumento utilizado, o número de aferições realizadas, o intervalo de descanso entre as aferições, a presença de estímulo verbal e de um pré-teste, também podem influenciar os valores alcançados por um indivíduo em uma avaliação da dinamometria manual. Dessa forma, é importante que um protocolo de aferição padronizado seja desenvolvido, para que se obtenham medidas válidas de dinamometria manual. Ainda são escassos os estudos que propõem valores de referência para a dinamometria manual e a literatura ainda se ressente de valores de referência baseados em dados obtidos a partir de amostras de base populacional.This paper reviews the methodological and physiological aspects of hand grip strength measurement. Hand grip strength assesses skeletal muscle function and has received increasing attention from physicians and health-related researchers in the last years. Recently, it has deserved particular attention as an indicator of nutritional status, particularly in hospitalized patients. Sex, age, height, body mass and the dominant hand of the subjects are the main factors that influence the measure. The results of this review demonstrate that many other factors associated with the assessment protocol, such as the position of the

  16. Management of spastic hand by selective peripheral neurotomies ...

    African Journals Online (AJOL)

    Introduction: Selective peripheral neurotomies (SPN) are proposed when spasticity is focalized on muscles that are under the control of a single or few peripheral nerves. Objective: This study was done to evaluate the functional results of SPN of median and ulnar nerves in 10 patients who had spastic hyperflexion of the ...

  17. A Strain-Based Method to Detect Tires’ Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development

    Directory of Open Access Journals (Sweden)

    Jorge Yunta

    2018-02-01

    Full Text Available Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire’s loss of grip and estimations of the lateral friction coefficient.

  18. Peripheral cold acclimatization in Antarctic scuba divers.

    Science.gov (United States)

    Bridgman, S A

    1991-08-01

    Peripheral acclimatization to cold in scuba divers stationed at the British Antarctic Survey's Signy Station was investigated during a year in Antarctica. Five divers and five non-diver controls underwent monthly laboratory tests of index finger immersion in cold water for 30 min. Index finger pulp temperature and time of onset of cold-induced vasodilatation (CIVD) were measured. Pain was recorded with verbal and numerical psychophysical subjective pain ratings. Average finger temperatures and median finger pain from 6-30 min of immersion, maximum finger temperatures during the first CIVD cycle, and finger temperatures at the onset of CIVD were calculated. Comparison of the variables recorded from divers and non-divers were performed with analysis of variance. No significant differences were found among the variables recorded from divers and non-divers. From a review of the literature, divers have responses typical of non-cold-adapted Caucasians. There is, therefore, no evidence that Signy divers peripherally acclimatized to cold. We suggest that these findings occur because either the whole body cooling which divers undergo inhibits peripheral acclimatization or because of insufficiently frequent or severe cold exposure while diving. Further basic studies on the duration, frequency and severity of cold exposure necessary to induce peripheral cold acclimatization are required before this question can be satisfactorily answered.

  19. Pathophysiology of Chemotherapy-Induced Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    Hana Starobova

    2017-05-01

    Full Text Available Chemotherapy-induced neuropathy is a common, dose-dependent adverse effect of several antineoplastics. It can lead to detrimental dose reductions and discontinuation of treatment, and severely affects the quality of life of cancer survivors. Clinically, chemotherapy-induced peripheral neuropathy presents as deficits in sensory, motor, and autonomic function which develop in a glove and stocking distribution due to preferential effects on longer axons. The pathophysiological processes are multi-factorial and involve oxidative stress, apoptotic mechanisms, altered calcium homeostasis, axon degeneration and membrane remodeling as well as immune processes and neuroinflammation. This review focusses on the commonly used antineoplastic substances oxaliplatin, cisplatin, vincristine, docetaxel, and paclitaxel which interfere with the cancer cell cycle—leading to cell death and tumor degradation—and cause severe acute and chronic peripheral neuropathies. We discuss drug mechanism of action and pharmacokinetic disposition relevant to the development of peripheral neuropathy, the epidemiology and clinical presentation of chemotherapy-induced neuropathy, emerging insight into genetic susceptibilities as well as current understanding of the pathophysiology and treatment approaches.

  20. The predictive value of extensor grip test for the effectiveness of treatment for tennis elbow

    International Nuclear Information System (INIS)

    Zehtab, Mohammad J.; Mirghasemi, A.; Majlesara, A.; Siavashi, B.; Tajik, P.

    2008-01-01

    Objective was to compare the effectiveness of 5 different modalities and determine the usefulness of recently proposed extensor grip test (EGT) in predicting the response to treatment. In a randomized controlled clinical trial, 92 of 98 tennis elbow patients in Sina Hospital Tehran, Iran between 2006 and 2007 fulfilled the trial entry criteria. Among these patients 56 (60.9%) had positive EGT results, were randomly allocated to 5 treatment groups: brace, physiotherapy, brace plus physiotherapy, injection and injection plus physiotherapy. Patients with a positive EGT result had better response to treatments. Among them, injection plus physiotherapy was the most successful, then brace plus physiotherapy was the worst treatment modality. Response to treatment was comparable in all groups between EGT positive and negative patients except bracing, in which positive EGT was correlated with dramatic response to treatment. In all patients, injection plus physiotherapy and the brace plus physiotherapy is recommended, but in EGT negatives, bracing seems to be of no use. Injection alone is not recommended in either group. (author)

  1. Simulation study of a single-grip harvester in thinning from below and thinning from above

    Energy Technology Data Exchange (ETDEWEB)

    Eliasson, Lars [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Silviculture; Lageson, Haakan [Forest Owner' s Ass. of Norrbotten, Boden (Sweden)

    1999-07-01

    The time consumption and productivity of a single-grip harvester were studied, using a simulation model, when thinning from below and above in eight randomly selected stands. The model estimated the time required for each work element, given machine and tree positions, and tree size. A 2 x 5 factorial design was used with factors thinning type [from below (T{sub b}) and above (T{sub a})] and tree size. Trees were subjectively selected for harvest according to thinning type. Total basal area removal was 30% plot{sup -1}. Approximately 50% more trees were harvested in T{sub b} than in T{sub a}. Time consumption tree{sup -1} was higher for T{sub a} than T{sub b}. Time consumption for machine and boom movements decreased with increasing number of harvested trees, and time for felling and processing of trees increased with harvested mean stem volume. Harvester productivity was 36% higher for T{sub a}, since the increase in harvested mean stem volume was higher than the increase in time consumption tree{sup -1}.

  2. Urbanization and the Resulting Peripheralization in Solo Raya, Indonesia

    Science.gov (United States)

    Pradoto, W.; Mardiansjah, F. H.; Manullang, O. R.; Putra, A. A.

    2018-02-01

    Dynamic urbanization in Solo Raya, a local term for Surakarta Metropolitan, amongst rapid regional based-urbanization in Indonesia, shows the unbalance pattern of growth. A number of Surakarta City’s peripherals become the newly growing area which is characterized by a well-facilitated region, while the former urbanized areas next to the city center present the declining process. Different socioeconomic development triggers a unique mosaic of socio-spatial pattern, on which the phenomena of peripheralization could be investigated. Urban investment that boosted by the political will of both the national and local government has led to a shift in demographic condition. A relatively massive in-migration has been attracted to the peripheral and creates the new landscape of urban-rural society. Complex dynamic of metropolitan growth and the resulting peripheralization reminds that socio-spatial pattern calls the challenges for managing the rapid change of land use and space use. The pattern of urbanization that differs upon the surrounding areas of Surakarta City would be interesting to be explored. This paper will discuss the conceptual framework of peripheral urbanization and the methodological approach. It is actually the part of ongoing research on peripheralisation in Solo Raya.

  3. The Members of the Agency

    International Nuclear Information System (INIS)

    2003-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.58) is Kyrgyzstan, which deposited the instrument of acceptance of the Statute on 10 September 2003. The list shows the dates on which the present 137 Member States became Members

  4. Peripheral endocannabinoids regulate skeletal muscle development and maintenance

    Directory of Open Access Journals (Sweden)

    Dongjiao Zhao

    2010-12-01

    Full Text Available As a principal tissue responsible for insulin-mediated glucose uptake, skeletal muscle is important for whole-body health. The role of peripheral endocannabinoids as regulators of skeletal muscle metabolism has recently gained a lot of interest, as endocannabinoid system disorders could cause peripheral insulin resistance. We investigated the role of the peripheral endocannabinoid system in skeletal muscle development and maintenance. Cultures of C2C12 cells, primary satellite cells and mouse skeletal muscle single fibers were used as model systems for our studies. We found an increase in cannabinoid receptor type 1 (CB1 mRNA and endocannabinoid synthetic enzyme mRNA skeletal muscle cells during differentiation. We also found that activation of CB1 inhibited myoblast differentiation, expanded the number of satellite cells, and stimulated the fast-muscle oxidative phenotype. Our findings contribute to understanding of the role of the endocannabinoid system in skeletal muscle metabolism and muscle oxygen consumption, and also help to explain the effects of the peripheral endocannabinoid system on whole-body energy balance.

  5. Micromethod for determination of cortisol in peripheral blood

    International Nuclear Information System (INIS)

    Maleeva, A.; Mileva, Zh.; Kekhajova, M.

    1982-01-01

    The micromethod for determination of cortisol in peripheral blood is based on the classical radiommunologic method for its determination. A drop of peripheral blood is applied on filter paper, used for detection of phenyketonuria. A 7 mm disk of this paper is then cut with a perforator and placed in the tube instead of 50 microliters blood plasma. The classical radiommunoassay and the micromethod were used in parallel for determining peripheral blood cortisol concentrations in 26 sexually mature persons, in 12 children and in 40 patients with thyroid hyperfunction. In all tested 78 persons no statistically significant difference (P>0.5) was found in cortisol concentrations, determined by the two methods. (authors)

  6. Thermal effects in concrete members

    International Nuclear Information System (INIS)

    Kar, A.K.

    1977-01-01

    When subjected to temperature changes and restrained from free movement, a member develops stresses. Restrained members are sometimes assumed to act independently of other members. A method of analysis and design for thermal stresses in such members is provided. The method of analysis, based on the ultimate strength concept, greatly reduces the computational efforts for determining thermal effects in concrete members. Available charts and tables and the recommendations given herein simplify the design. (Auth.)

  7. Effect of peripheral morphine in a human model of acute inflammatory pain

    DEFF Research Database (Denmark)

    Lillesø, J; Hammer, N A; Pedersen, J L

    2000-01-01

    Several studies have demonstrated the presence of opioid inducible receptors on peripheral nerves and peripheral antinociceptive effects of opioids. However, the effects of peripheral opioid administration in man are controversial. Our study used a randomized, double-blind, placebo-controlled, th......Several studies have demonstrated the presence of opioid inducible receptors on peripheral nerves and peripheral antinociceptive effects of opioids. However, the effects of peripheral opioid administration in man are controversial. Our study used a randomized, double-blind, placebo......-controlled, three-way crossover design in a human model of acute inflammatory pain (heat injury). We studied 18 healthy volunteers who each received morphine locally (2 mg), morphine systemically (2 mg), or placebo on three separate study days. The subjects received morphine infiltration subcutaneously (s.c.). 1 h......, but local morphine infiltration neither reduced pain during the burn, nor primary or secondary hyperalgesia to mechanical and heat stimuli after the burn. In conclusion, peripherally applied morphine had no acute antinociceptive effects in this human model of acute inflammatory pain....

  8. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.67) is Cambodia which deposited its Instrument of Acceptance of the Statute on 23 November 2009. The Attachment hereto shows the dates on which the present 151 Member States became Members [fr

  9. The Members of the Agency

    International Nuclear Information System (INIS)

    2007-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.63) is Palau which deposited its Instrument of Acceptance of the Statute on 2 March 2007. The Attachment hereto shows the dates on which the present 144 Member States became Members

  10. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.67) is Cambodia which deposited its Instrument of Acceptance of the Statute on 23 November 2009. The Attachment hereto shows the dates on which the present 151 Member States became Members

  11. The Members of the Agency

    International Nuclear Information System (INIS)

    2008-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.64) is Nepal which deposited its Instrument of Acceptance of the Statute on 8 July 2008. The Attachment hereto shows the dates on which the present 145 Member States became Members

  12. The Members of the Agency

    International Nuclear Information System (INIS)

    2006-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.62) is Montenegro which deposited its Instrument of Acceptance of the Statute on 30 October 2006. The Attachment hereto shows the dates on which the present 143 Member States became Members

  13. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.67) is Cambodia which deposited its Instrument of Acceptance of the Statute on 23 November 2009. The Attachment hereto shows the dates on which the present 151 Member States became Members [ru

  14. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.67) is Cambodia which deposited its Instrument of Acceptance of the Statute on 23 November 2009. The Attachment hereto shows the dates on which the present 151 Member States became Members [es

  15. The Members of the Agency

    International Nuclear Information System (INIS)

    2006-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.60) is Chad, which deposited the instrument of acceptance of the Statute on 2 November 2005. The Attachment hereto shows the dates on which the present 139 Member States became Members

  16. Muscle Fatigue in the Three Heads of the Triceps Brachii During a Controlled Forceful Hand Grip Task with Full Elbow Extension Using Surface Electromyography.

    Science.gov (United States)

    Ali, Asraf; Sundaraj, Kenneth; Badlishah Ahmad, R; Ahamed, Nizam Uddin; Islam, Anamul; Sundaraj, Sebastian

    2015-06-27

    The objective of the present study was to investigate the time to fatigue and compare the fatiguing condition among the three heads of the triceps brachii muscle using surface electromyography during an isometric contraction of a controlled forceful hand grip task with full elbow extension. Eighteen healthy subjects concurrently performed a single 90 s isometric contraction of a controlled forceful hand grip task and full elbow extension. Surface electromyographic signals from the lateral, long and medial heads of the triceps brachii muscle were recorded during the task for each subject. The changes in muscle activity among the three heads of triceps brachii were measured by the root mean square values for every 5 s period throughout the total contraction period. The root mean square values were then analysed to determine the fatiguing condition for the heads of triceps brachii muscle. Muscle fatigue in the long, lateral, and medial heads of the triceps brachii started at 40 s, 50 s, and 65 s during the prolonged contraction, respectively. The highest fatiguing rate was observed in the long head (slope = -2.863), followed by the medial head (slope = -2.412) and the lateral head (slope = -1.877) of the triceps brachii muscle. The results of the present study concurs with previous findings that the three heads of the triceps brachii muscle do not work as a single unit, and the fiber type/composition is different among the three heads.

  17. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.65) is the Sultanate of Oman which deposited its Instrument of Acceptance of the Statute on 5 February 2009. The Attachment hereto shows the dates on which the present 146 Member States became Members

  18. THE INFLUENCE OF PERIPHERAL NEUROPATHY AND PERIPHERAL VASCULAR DISEASE IN THE OUTCOME OF DIABETIC FOOT MANAGEMENT – A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Sundar Prakash S, Krishnakumar, Chandra Prabha

    2015-04-01

    Full Text Available Objective: Peripheral neuropathy and Peripheral Vascular Disease are the risk factors for the development of diabetic foot. The aim of this study was to evaluate differences and predictors of outcome parameters in patients with diabetic foot by stratifying these subjects according to the severity of these risk factors. Materials and methods: This is a prospective study conducted in 70 patients in the age group of 30-90 years diagnosed as Type II Diabetes with foot ulcers. After detailed clinical examination the following tests were conducted in all the patients: Complete blood count (CBC, Haemoglobin (Hb, Random Blood Sugar (RBS, Erythrocyte Sedimentation rate (ESR, Chest X-ray(CXR, Electrocardiography (ECG, foot X-ray, pus culture, Neuropathy testing by Semmes Weinstein Monofilament Test and Vibration Perception Threshold and Peripheral vascularity assessment by Duplex Doppler. Then grading of the ulcers was done using Wagner’s Grade. The outcome of the patients was assessed by recording the healing time, mode of surgery and amputation rates of the patients. Results: A total of 70 patients with diabetic foot were consecutively included into the study (65.7% male, age (31% in 51-60 years, mean diabetes duration (5.2 years, Ulcer Grade (37% in Grade IV, Foot lesions (45.7% in toe, Blood sugar levels (64% in 300-400 mg/dl, Neuropathy (84%, Peripheral vascular disease (67%, major amputation (7% and mortality (1.4%. Conclusion: All diabetic patients should undergo testing for neuropathy and peripheral vascular disease apart from doing other tests.

  19. Human pigmentation: A side effect adapted from a primitive organism′s survival, acting through cell attachment with an affinity for the keratinocyte and for elastin: Part I

    Directory of Open Access Journals (Sweden)

    Sanju Arianayagam

    2014-01-01

    Full Text Available Pigmentation featured millions of years ago and perhaps began with an amoeba frightening off a predator with some agent such as dopamine to prevent its attachment for phagocytosis by an enemy. This paper suggests that the environmental forces of grip and stick deserve greater emphasis and that mechanical forces involved in grip and stick or release from attachment, all point to control of proteases underlying pigmentation. There is an affinity for elastin as a pathway for melanin to exit its peripheral location in the epidermis into lymphatics and play a humeral role in defense mechanisms. The hair follicle follows the epidermal-dermal pattern of behavior with an affinity for elastin, a controlling function of melanin and through the bulge, an influence of mechanical forces and control by protease inhibitors.

  20. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.65) is the Sultanate of Oman which deposited its Instrument of Acceptance of the Statute on 5 February 2009. The Attachment hereto shows the dates on which the present 146 Member States became Members [fr

  1. The Members of the Agency

    International Nuclear Information System (INIS)

    2005-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.59) is the Islamic Republic of Mauritania, which deposited the instrument of acceptance of the Statute on 23 November 2004. The Attachment hereto shows the dates on which the present 138 Member States became Members

  2. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Member since the last list of Member States was issued (INFCIRC/2/Rev.65) is the Sultanate of Oman which deposited its Instrument of Acceptance of the Statute on 5 February 2009. The Attachment hereto shows the dates on which the present 146 Member States became Members [es

  3. Diabetic peripheral neuropathy, is it an autoimmune disease?

    Science.gov (United States)

    Janahi, Noor M; Santos, Derek; Blyth, Christine; Bakhiet, Moiz; Ellis, Mairghread

    2015-11-01

    Autoimmunity has been identified in a significant number of neuropathies, such as, proximal neuropathies, and autonomic neuropathies associated with diabetes mellitus. However, possible correlations between diabetic peripheral neuropathy and autoimmunity have not yet been fully investigated. This study was conducted to investigate whether autoimmunity is associated with the pathogenesis of human diabetic peripheral neuropathy. A case-control analysis included three groups: 30 patients with diabetic peripheral neuropathy, 30 diabetic control patients without neuropathy, and 30 healthy controls. Blood analysis was conducted to compare the percentages of positive antinuclear antibodies (ANA) between the three groups. Secondary analysis investigated the correlations between the presence of autoimmune antibodies and sample demographics and neurological manifestations. This research was considered as a pilot study encouraging further investigations to take place in the near future. Antinuclear antibodies were significantly present in the blood serum of patients with diabetic peripheral neuropathy in comparison to the control groups (pneuropathy group were 50 times higher when compared to control groups. Secondary analysis showed a significant correlation between the presence of ANA and the neurological manifestation of neuropathy (Neuropathy symptom score, Neuropathy disability score and Vibration Perception Threshold). The study demonstrated for the first time that human peripheral diabetic neuropathy may have an autoimmune aetiology. The new pathogenic factors may lead to the consideration of new management plans involving new therapeutic approaches and disease markers. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Comprehensive management of presbycusis: central and peripheral.

    Science.gov (United States)

    Parham, Kourosh; Lin, Frank R; Coelho, Daniel H; Sataloff, Robert T; Gates, George A

    2013-04-01

    The prevailing otolaryngologic approach to treatment of age-related hearing loss (ARHL), presbycusis, emphasizes compensation of peripheral functional deficits (ie, hearing aids and cochlear implants). This approach does not address adequately the needs of the geriatric population, 1 in 5 of whom is expected to consist of the "old old" in the coming decades. Aging affects both the peripheral and central auditory systems, and disorders of executive function become more prevalent with advancing age. Growing evidence supports an association between age-related hearing loss and cognitive decline. Thus, to facilitate optimal functional capacity in our geriatric patients, a more comprehensive management strategy of ARHL is needed. Diagnostic evaluation should go beyond standard audiometric testing and include measures of central auditory function, including dichotic tasks and speech-in-noise testing. Treatment should include not only appropriate means of peripheral compensation but also auditory rehabilitative training and counseling.

  5. Contrast media and pain during peripheral arteriography

    International Nuclear Information System (INIS)

    Hagen, B.; Clauss, W.

    1982-01-01

    Some contrast media (CM) were for inducing pain and heat by an intraindividual comparison in 60 patients with occlusive peripheral arterial disease. A dolorimeter and calorimeter (graduated scales) were employed to register and differentiate the subjective sensations experienced by the patient, while objective reactions (peripheral motoric reactions, circulatory parameters) were recorded by the trialist at the same time. Ioxaglate, an ionic dimer, was distinctly superior to Ioglicinate, an ionic CM. However, the differences were less marked in the comparison with a Ioglicinate-Lidocaine-mixture. Emphasis is given to the fact osmolality is the most important parameter in the development of pain. Potential points at which the intraarterially administered local anaesthetic could attack are discussed. The clinical conclusions include consideration of the cost-effectivity ratios of the tested CM's and a discussion of whether or not modern stanards still justify general anaesthesia for peripheral angiography. (orig.)

  6. Quality assessment of online patient education resources for peripheral neuropathy.

    Science.gov (United States)

    Hansberry, David R; Suresh, Ragha; Agarwal, Nitin; Heary, Robert F; Goldstein, Ira M

    2013-03-01

    Given its practicality, the internet is a primary resource for patients afflicted with diseases like peripheral neuropathy. Therefore, it is important that the readily available online resources on peripheral neuropathy are tailored to the general public, particularly concerning readability. Patient education resources were downloaded from the US National Library of Medicine, Mayo Clinic, National Institute of Neurological Disorders and Stroke, Neuropathy.org, GBS/CIDP Foundation International, Hereditary Neuropathy Foundation, Charcot-Marie-Tooth Association, Foundation for Peripheral Neuropathy, and Neuropathy Action Foundation websites. All patient education material related to peripheral neuropathy was evaluated for its level of readability using the Flesch Reading Ease (FRE) and Flesch-Kincaid Grade Level. The FRE scores averaged 43.4 with only the US National Library of Medicine scoring above 60 (76.5). The Flesch-Kincaid Grade Level scores averaged 11.0. All scores were above a seventh-grade level except the US National Library of Medicine, which had a score of a fifth-grade reading level. Most Americans may not fully benefit from patient education resources concerning peripheral neuropathy education on many of the websites. Only the US National Library of Medicine, which is written at a fifth-grade level, is likely to benefit the average American. © 2013 Peripheral Nerve Society.

  7. Chemotherapy-induced peripheral neuropathy : Impact on quality of life

    NARCIS (Netherlands)

    Scheel, A.; Beijers, A.J.M.; Mols, F.; Faber, C.G.; Vreugdenhil, G.

    2014-01-01

    Peripheral neuropathy is a frequently occurring side-effect of chemotherapy as a cancer treatment. The incidence of chemotherapy-induced peripheral neuropathy (CIPN) is increasing as a consequence of better treatment of cancer becoming available and increasing use of chemotherapy, and because CIPN

  8. Clinical Outcomes of Living Liver Transplantation According to the Presence of Sarcopenia as Defined by Skeletal Muscle Mass, Hand Grip, and Gait Speed.

    Science.gov (United States)

    Harimoto, N; Yoshizumi, T; Izumi, T; Motomura, T; Harada, N; Itoh, S; Ikegami, T; Uchiyama, H; Soejima, Y; Nishie, A; Kamishima, T; Kusaba, R; Shirabe, K; Maehara, Y

    2017-11-01

    Sarcopenia is an independent predictor of death after living-donor liver transplantation (LDLT). However, the ability of the Asian Working Group for Sarcopenia criteria for sarcopenia (defined as reduced skeletal muscle mass plus low muscle strength) to predict surgical outcomes in patients who have undergone LDLT has not been determined. This study prospectively enrolled 366 patients who underwent LDLT at Kyushu University Hospital. Skeletal muscle area (determined by computed tomography), hand-grip strength, and gait speed were measured in 102 patients before LDLT. We investigated the relationship between sarcopenia and surgical outcomes after LDLT performed in three time periods. The number of patients with lower skeletal muscle area has increased to 52.9% in recent years. The incidence of sarcopenia according to the Asian Working Group for Sarcopenia criteria was 23.5% (24/102). Patients with sarcopenia (defined by skeletal muscle area and functional parameters) had significantly lower skeletal muscle area and weaker hand-grip strength than did those without sarcopenia. Compared with non-sarcopenic patients, patients with sarcopenia also had significantly worse liver function, greater estimated blood loss, greater incidence of postoperative complications of Clavien-Dindo grade IV or greater (including amount of ascites on postoperative day 14, total bilirubin on postoperative day 14, and postoperative sepsis), and longer postoperative hospital stay. Multiple logistic regression analysis revealed sarcopenia as a significant predictor of 6-month mortality. The combination of skeletal muscle mass and function can predict surgical outcomes in LDLT patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Hurricane Imaging Radiometer (HIRAD) Observations of Brightness Temperatures and Ocean Surface Wind Speed and Rain Rate During NASA's GRIP and HS3 Campaigns

    Science.gov (United States)

    Miller, Timothy L.; James, M. W.; Roberts, J. B.; Jones, W. L.; Biswas, S.; Ruf, C. S.; Uhlhorn, E. W.; Atlas, R.; Black, P.; Albers, C.

    2012-01-01

    HIRAD flew on high-altitude aircraft over Earl and Karl during NASA s GRIP (Genesis and Rapid Intensification Processes) campaign in August - September of 2010, and plans to fly over Atlantic tropical cyclones in September of 2012 as part of the Hurricane and Severe Storm Sentinel (HS3) mission. HIRAD is a new C-band radiometer using a synthetic thinned array radiometer (STAR) technology to obtain spatial resolution of approximately 2 km, out to roughly 30 km each side of nadir. By obtaining measurements of emissions at 4, 5, 6, and 6.6 GHz, observations of ocean surface wind speed and rain rate can be retrieved. The physical retrieval technique has been used for many years by precursor instruments, including the Stepped Frequency Microwave Radiometer (SFMR), which has been flying on the NOAA and USAF hurricane reconnaissance aircraft for several years to obtain observations within a single footprint at nadir angle. Results from the flights during the GRIP and HS3 campaigns will be shown, including images of brightness temperatures, wind speed, and rain rate. Comparisons will be made with observations from other instruments on the campaigns, for which HIRAD observations are either directly comparable or are complementary. Features such as storm eye and eye-wall, location of storm wind and rain maxima, and indications of dynamical features such as the merging of a weaker outer wind/rain maximum with the main vortex may be seen in the data. Potential impacts on operational ocean surface wind analyses and on numerical weather forecasts will also be discussed.

  10. Optimization of Peripheral Finned-Tube Evaporators Using Entropy Generation Minimization

    OpenAIRE

    Pussoli, Bruno; Barbosa Jr., Jader; da Silva, Luciana; Kaviany, Massoud

    2012-01-01

    The peripheral finned-tube (PFT) is a new geometry for enhanced air-side heat transfer under moisture condensate blockage (evaporators). It consists of individual hexagonal (peripheral) fin arrangements with radial fins whose bases are attached to the tubes and tips are interconnected with the peripheral fins. In this paper, experimentally validated semi-empirical models for the air-side heat transfer and pressure drop are combined with the entropy generation minimization theory to determine ...

  11. File list: Unc.Bld.20.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.20.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.20.AllAg.Peripheral_blood.bed ...

  12. File list: Unc.Bld.50.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.50.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.50.AllAg.Peripheral_blood.bed ...

  13. Altered visual strategies and attention are related to increased force fluctuations during a pinch grip task in older adults.

    Science.gov (United States)

    Keenan, Kevin G; Huddleston, Wendy E; Ernest, Bradley E

    2017-11-01

    The purpose of the study was to determine the visual strategies used by older adults during a pinch grip task and to assess the relations between visual strategy, deficits in attention, and increased force fluctuations in older adults. Eye movements of 23 older adults (>65 yr) were monitored during a low-force pinch grip task while subjects viewed three common visual feedback displays. Performance on the Grooved Pegboard test and an attention task (which required no concurrent hand movements) was also measured. Visual strategies varied across subjects and depended on the type of visual feedback provided to the subjects. First, while viewing a high-gain compensatory feedback display (horizontal bar moving up and down with force), 9 of 23 older subjects adopted a strategy of performing saccades during the task, which resulted in 2.5 times greater force fluctuations in those that exhibited saccades compared with those who maintained fixation near the target line. Second, during pursuit feedback displays (force trace moving left to right across screen and up and down with force), all subjects exhibited multiple saccades, and increased force fluctuations were associated ( r s = 0.6; P = 0.002) with fewer saccades during the pursuit task. Also, decreased low-frequency (attention z scores. Comparison of these results with our previously published results in young subjects indicates that saccadic eye movements and attention are related to force control in older adults. NEW & NOTEWORTHY The significant contributions of the study are the addition of eye movement data and an attention task to explain differences in hand motor control across different visual displays in older adults. Older participants used different visual strategies across varying feedback displays, and saccadic eye movements were related with motor performance. In addition, those older individuals with deficits in attention had impaired motor performance on two different hand motor control tasks, including

  14. The comparison of CT findings between peripheral pulmonary squamous cell carcinoma and pulmonary adenocarcinoma

    International Nuclear Information System (INIS)

    Tan Guosheng; Yang Xufeng; Zhou Xuhui; Li Ziping; Fan Miao; Chen Jindi

    2007-01-01

    Objective: To compare the principal HRCT features of peripheral pulmonary squamous cell carcinoma and pulmonary adenocarcinoma and to explore their pathological mechanism, in order to improve the recognition of the CT signs of peripheral pulmonary carcinoma. Methods: The principal HRCT signs of thirty-five cases with pathologically proved peripheral pulmonary squamous cell carcinoma and forty cases with pathologically proved peripheral pulmonary adenocarcinoma were analyzed retrospectively to explore the relationship between CT features and pathological findings. Results: The main features of peripheral pulmonary squamous cell carcinoma included larger masses, clear boundary, superficial sublobes and intra-tumor necrosis. While peripheral pulmonary adenocarcinoma mostly demonstrated as smaller nodules, deep sublobes, spiculations, spiculate protuberance, pleural indentation, vessel converging signs, and vacuole signs. The different of these above findings of peripheral pulmonary squamous cell carcinoma and adenocarcinoma were significant (P<0.05). Peripheral pulmonary squamous cell carcinoma may depict bronchial casts and polygonal nodules; and peripheral pulmonary adenocarcinoma may demonstrate ground glass-like nodules. Conclusion: The difference of the CT findings between peripheral pulmonary squamous cell carcinoma and peripheral adenocarcinoma is based on their different histological features and biological behaviors. It is possible to differentiate them before operation in combination with clinical information. (authors)

  15. Statin use and peripheral sensory perception: a pilot study.

    Science.gov (United States)

    West, Brenton; Williams, Cylie M; Jilbert, Elise; James, Alicia M; Haines, Terry P

    2014-06-01

    Peripheral sensory neuropathy is a neurological deficit resulting in decreased detection of sensation through the peripheral nervous system. Peripheral sensory neuropathy is commonly diagnosed with the use of a monofilament and either a tuning fork or neurothesiometer. Statins are a widely used medication and there has been some debate of association with their use and peripheral sensory neuropathy. This pilot study aimed to test the sensory perception of participants with long-term statin use and compare these results to their peers who were not taking statins. Thirty participants were recruited and equally divided into a statin and non-statin group. Healthy participants were screened by their medical and medication history, Australian Type 2 Diabetes Risk assessment, and random blood glucose level. An assessor who was blinded to the participant group conducted sensory assessments using a 10 g monofilament and neurothesiometer. There was no difference in monofilament testing results between the groups. The statin group was less sensate at the styloid process (p = 0.031) and medial malleolus (p = 0.003) than the control group. Results at the hallux were not statistically significant (p = 0.183). This result is suggestive of a potential association between long-term statin use and a decrease in peripheral sensory perception. This may be because of peripheral sensory neuropathy. Limitations such as consideration of participant height, participant numbers, and inability to analyze results against statin groups are reported. As statins are a life-saving medication, careful consideration should be applied to these results and further research be conducted to determine if these results are applicable to larger populations.

  16. Electrophysiological measurements of diabetic peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Shabeeb, Dheyauldeen; Najafi, Masoud; Hasanzadeh, Gholamreza; Hadian, Mohammed Reza; Musa, Ahmed Eleojio; Shirazi, Alireza

    2018-03-28

    Peripheral neuropathy is one of the main complications of diabetes mellitus. One of the features of diabetic nerve damage is abnormality of sensory and motor nerve conduction study. An electrophysiological examination can be reproduced and is also a non-invasive approach in the assessment of peripheral nerve function. Population-based and clinical studies have been conducted to validate the sensitivity of these methods. When the diagnosis was based on clinical electrophysiological examination, abnormalities were observed in all patients. In this research, using a review design, we reviewed the issue of clinical electrophysiological examination of diabetic peripheral neuropathy in articles from 2008 to 2017. For this purpose, PubMed, Scopus and Embase databases of journals were used for searching articles. The researchers indicated that diabetes (both types) is a very disturbing health issue in the modern world and should be given serious attention. Based on conducted studies, it was demonstrated that there are different procedures for prevention and treatment of diabetes-related health problems such as diabetic polyneuropathy (DPN). The first objective quantitative indication of the peripheral neuropathy is abnormality of sensory and motor nerve conduction tests. Electrophysiology is accurate, reliable and sensitive. It can be reproduced and also is a noninvasive approach in the assessment of peripheral nerve function. The methodological review has found that the best method for quantitative indication of the peripheral neuropathy compared with all other methods is clinical electrophysiological examination. For best results, standard protocols such as temperature control and equipment calibration are recommended. Copyright © 2018. Published by Elsevier Ltd.

  17. The Members of the Agency

    International Nuclear Information System (INIS)

    2006-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.61) are Belize, Mozambique and Malawi, which deposited their Instruments of Acceptance of the Statute on 31 March 2006, 18 September 2006 and 2 October 2006 respectively. The Attachment hereto shows the dates on which the present 142 Member States became Members [fr

  18. The Members of the Agency

    International Nuclear Information System (INIS)

    2006-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.61) are Belize, Mozambique and Malawi, which deposited their Instruments of Acceptance of the Statute on 31 March 2006, 18 September 2006 and 2 October 2006 respectively. The Attachment hereto shows the dates on which the present 142 Member States became Members

  19. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  20. Network node for peripheral sharing

    International Nuclear Information System (INIS)

    Bobbitt, J.; Johnson, M.

    1977-01-01

    A module which enables several independent computer systems to share the peripherals (graphics display and line printer) of a PDP-11 computer is described. The module requires no software support in the PDP-11

  1. File list: Unc.Bld.10.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.10.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66,SRX1080067 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.10.AllAg.Peripheral_blood.bed ...

  2. File list: Unc.Bld.05.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.05.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66,SRX1080067 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.05.AllAg.Peripheral_blood.bed ...

  3. Peripheral arterial disease and revascularization of the diabetic foot.

    Science.gov (United States)

    Forsythe, R O; Brownrigg, J; Hinchliffe, R J

    2015-05-01

    Diabetes is a complex disease with many serious potential sequelae, including large vessel arterial disease and microvascular dysfunction. Peripheral arterial disease is a common large vessel complication of diabetes, implicated in the development of tissue loss in up to half of patients with diabetic foot ulceration. In addition to peripheral arterial disease, functional changes in the microcirculation also contribute to the development of a diabetic foot ulcer, along with other factors such as infection, oedema and abnormal biomechanical loading. Peripheral arterial disease typically affects the distal vessels, resulting in multi-level occlusions and diffuse disease, which often necessitates challenging distal revascularisation surgery or angioplasty in order to improve blood flow. However, technically successful revascularisation does not always result in wound healing. The confounding effects of microvascular dysfunction must be recognised--treatment of a patient with a diabetic foot ulcer and peripheral arterial disease should address this complex interplay of pathophysiological changes. In the case of non-revascularisable peripheral arterial disease or poor response to conventional treatment, alternative approaches such as cell-based treatment, hyperbaric oxygen therapy and the use of vasodilators may appear attractive, however more robust evidence is required to justify these novel approaches. © 2014 John Wiley & Sons Ltd.

  4. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  5. Peripheral changes in endometriosis-associated pain

    Science.gov (United States)

    Morotti, Matteo; Vincent, Katy; Brawn, Jennifer; Zondervan, Krina T.; Becker, Christian M.

    2014-01-01

    BACKGROUND Pain remains the cardinal symptom of endometriosis. However, to date, the underlying mechanisms are still only poorly understood. Increasing evidence points towards a close interaction between peripheral nerves, the peritoneal environment and the central nervous system in pain generation and processing. Recently, studies demonstrating nerve fibres and neurotrophic and angiogenic factors in endometriotic lesions and their vicinity have led to increased interest in peripheral changes in endometriosis-associated pain. This review focuses on the origin and function of these nerves and factors as well as possible peripheral mechanisms that may contribute to the generation and modulation of pain in women with endometriosis. METHODS We conducted a systematic search using several databases (PubMed, MEDLINE, EMBASE and CINAHL) of publications from January 1977 to October 2013 to evaluate the possible roles of the peripheral nervous system in endometriosis pathophysiology and how it can contribute to endometriosis-associated pain. RESULTS Endometriotic lesions and peritoneal fluid from women with endometriosis had pronounced neuroangiogenic properties with increased expression of new nerve fibres, a shift in the distribution of sensory and autonomic fibres in some locations, and up-regulation of several neurotrophins. In women suffering from deep infiltrating endometriosis and bowel endometriosis, in which the anatomical distribution of lesions is generally more closely related to pelvic pain symptoms, endometriotic lesions and surrounding tissues present higher nerve fibre densities compared to peritoneal lesions and endometriomas. More data are needed to fully confirm a direct correlation between fibre density in these locations and the amount of perceived pain. A better correlation between the presence of nerve fibres and pain symptoms seems to exist for eutopic endometrium. However, this appears not to be exclusive to endometriosis. No correlation between

  6. Auditory attention activates peripheral visual cortex.

    Directory of Open Access Journals (Sweden)

    Anthony D Cate

    Full Text Available BACKGROUND: Recent neuroimaging studies have revealed that putatively unimodal regions of visual cortex can be activated during auditory tasks in sighted as well as in blind subjects. However, the task determinants and functional significance of auditory occipital activations (AOAs remains unclear. METHODOLOGY/PRINCIPAL FINDINGS: We examined AOAs in an intermodal selective attention task to distinguish whether they were stimulus-bound or recruited by higher-level cognitive operations associated with auditory attention. Cortical surface mapping showed that auditory occipital activations were localized to retinotopic visual cortex subserving the far peripheral visual field. AOAs depended strictly on the sustained engagement of auditory attention and were enhanced in more difficult listening conditions. In contrast, unattended sounds produced no AOAs regardless of their intensity, spatial location, or frequency. CONCLUSIONS/SIGNIFICANCE: Auditory attention, but not passive exposure to sounds, routinely activated peripheral regions of visual cortex when subjects attended to sound sources outside the visual field. Functional connections between auditory cortex and visual cortex subserving the peripheral visual field appear to underlie the generation of AOAs, which may reflect the priming of visual regions to process soon-to-appear objects associated with unseen sound sources.

  7. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.66) are Bahrain, Burundi, Congo and Lesotho which deposited their Instruments of Acceptance of the Statute on 23 June 2009, 24 June 2009, 15 July 2009 and 13 July 2009, respectively. The Attachment hereto shows the dates on which the present 150 Member States became Members [fr

  8. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.66) are Bahrain, Burundi, Congo and Lesotho which deposited their Instruments of Acceptance of the Statute on 23 June 2009, 24 June 2009, 15 July 2009 and 13 July 2009, respectively. The Attachment hereto shows the dates on which the present 150 Member States became Members

  9. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.66) are Bahrain, Burundi, Congo and Lesotho which deposited their Instruments of Acceptance of the Statute on 23 June 2009, 24 June 2009, 15 July 2009 and 13 July 2009, respectively. The Attachment hereto shows the dates on which the present 150 Member States became Members [ru

  10. The Members of the Agency

    International Nuclear Information System (INIS)

    2009-01-01

    The new Members since the last list of Member States was issued (INFCIRC/2/Rev.66) are Bahrain, Burundi, Congo and Lesotho which deposited their Instruments of Acceptance of the Statute on 23 June 2009, 24 June 2009, 15 July 2009 and 13 July 2009, respectively. The Attachment hereto shows the dates on which the present 150 Member States became Members [es

  11. Digital interface for bi-directional communication between a computer and a peripheral device

    Science.gov (United States)

    Bond, H. H., Jr. (Inventor); Franklin, C. R.

    1984-01-01

    For transmission of data from the computer to the peripheral, the computer initially clears a flipflop which provides a select signal to a multiplexer. A data available signal or data strobe signal is produced while tht data is being provided to the interface. Setting of the flipflop causes a gate to provide to the peripherial a signal indicating that the interface has data available for transmission. The peripheral provides an acknowledge or strobe signal to transfer the data to the peripheral. For transmission of data from the peripheral to the computer, the computer presents the initially cleared flipflop. A data request signal from the peripheral indicates that the peripheral has data available for transmission to the computer. An acknowledge signal indicates that the interface is ready to receive data from the peripheral and to strobe that data into the interface.

  12. Trichloropropane and dichlorohydrin associated with painful peripheral neurotoxicity.

    Science.gov (United States)

    Shi, Xiaobing; Yu, Shengyuan

    2013-10-01

    Trichloropropane (TCP) and dichlorohydrin are widely used in industrial production; however, TCP and dichlorohydrin poisoning are rarely encountered in clinical practice. There have been no cases of peripheral neurotoxicity previously reported. A cluster of 23 patients who had been exposed to high levels of TCP and dichlorohydrin presented with painful peripheral neuropathy, and the pain was assessed using a visual analogue scale (VAS). Nerve conduction studies (NCS) were performed in all patients. All patients demonstrated symmetrical pin-prick pain in a stocking distribution in the lower limbs, with VAS scores between 3 and 10, with an average score of 6.8. NCS showed a mild mixture of axonal and demyelinating sensorimotor polyneuropathy in 14 of the 23 patients. After administration of standard neuropathic pain medication, pain was relieved in most patients. Painful peripheral neuropathy was the primary symptom observed in our patients, which differs from clinical and animal model reports of TCP or dichlorohydrin poisoning. However, the pathogenesis remains unidentified. TCP may be added to the list of industrial products that are toxic to the peripheral sensory nerves. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Central and Peripheral Components of Working Memory Storage

    Science.gov (United States)

    Cowan, Nelson; Saults, J. Scott; Blume, Christopher L.

    2014-01-01

    This study re-examines the issue of how much of working memory storage is central, or shared across sensory modalities and verbal and nonverbal codes, and how much is peripheral, or specific to a modality or code. In addition to the exploration of many parameters in 9 new dual-task experiments and re-analysis of some prior evidence, the innovations of the present work compared to previous studies of memory for two stimulus sets include (1) use of a principled set of formulas to estimate the number of items in working memory, and (2) a model to dissociate central components, which are allocated to very different stimulus sets depending on the instructions, from peripheral components, which are used for only one kind of material. We consistently find that the central contribution is smaller than was suggested by Saults and Cowan (2007), and that the peripheral contribution is often much larger when the task does not require the binding of features within an object. Previous capacity estimates are consistent with the sum of central plus peripheral components observed here. We consider the implications of the data as constraints on theories of working memory storage and maintenance. PMID:24867488

  14. 3D printing strategies for peripheral nerve regeneration.

    Science.gov (United States)

    Petcu, Eugen B; Midha, Rajiv; McColl, Erin; Popa-Wagner, Aurel; Chirila, Traian V; Dalton, Paul D

    2018-03-23

    After many decades of biomaterials research for peripheral nerve regeneration, a clinical product (the nerve guide), is emerging as a proven alternative for relatively short injury gaps. This review identifies aspects where 3D printing can assist in improving long-distance nerve guide regeneration strategies. These include (1) 3D printing of the customizable nerve guides, (2) fabrication of scaffolds that fill nerve guides, (3) 3D bioprinting of cells within a matrix/bioink into the nerve guide lumen and the (4) establishment of growth factor gradients along the length a nerve guide. The improving resolution of 3D printing technologies will be an important factor for peripheral nerve regeneration, as fascicular-like guiding structures provide one path to improved nerve guidance. The capability of 3D printing to manufacture complex structures from patient data based on existing medical imaging technologies is an exciting aspect that could eventually be applied to treating peripheral nerve injury. Ultimately, the goal of 3D printing in peripheral nerve regeneration is the automated fabrication, potentially customized for the patient, of structures within the nerve guide that significantly outperform the nerve autograft over large gap injuries.

  15. Vitamin B supplementation for diabetic peripheral neuropathy.

    Science.gov (United States)

    Jayabalan, Bhavani; Low, Lian Leng

    2016-02-01

    Vitamin B12 deficiency has been associated with significant neurological pathology, especially peripheral neuropathy. This review aims to examine the existing evidence on the effectiveness of vitamin B12 supplementation for the treatment of diabetic peripheral neuropathy. A search of PubMed and the Cochrane Central Register of Controlled Trials for all relevant randomised controlled trials was conducted in December 2014. Any type of therapy using vitamin B12 or its coenzyme forms was assessed for efficacy and safety in diabetics with peripheral neuropathy. Changes in vibration perception thresholds, neuropathic symptoms and nerve conduction velocities, as well as the adverse effects of vitamin B12 therapy, were assessed. Four studies comprising 363 patients met the inclusion criteria. This review found no evidence that the use of oral vitamin B12 supplements is associated with improvement in the clinical symptoms of diabetic neuropathy. Furthermore, the majority of studies reported no improvement in the electrophysiological markers of nerve conduction. Copyright © Singapore Medical Association.

  16. Iron Homeostasis in Peripheral Nervous System, Still a Black Box?

    Science.gov (United States)

    Taveggia, Carla

    2014-01-01

    Abstract Significance: Iron is the most abundant transition metal in biology and an essential cofactor for many cellular enzymes. Iron homeostasis impairment is also a component of peripheral neuropathies. Recent Advances: During the past years, much effort has been paid to understand the molecular mechanism involved in maintaining systemic iron homeostasis in mammals. This has been stimulated by the evidence that iron dyshomeostasis is an initial cause of several disorders, including genetic and sporadic neurodegenerative disorders. Critical Issues: However, very little has been done to investigate the physiological role of iron in peripheral nervous system (PNS), despite the development of suitable cellular and animal models. Future Directions: To stimulate research on iron metabolism and peripheral neuropathy, we provide a summary of the knowledge on iron homeostasis in the PNS, on its transport across the blood–nerve barrier, its involvement in myelination, and we identify unresolved questions. Furthermore, we comment on the role of iron in iron-related disorder with peripheral component, in demyelinating and metabolic peripheral neuropathies. Antioxid. Redox Signal. 21, 634–648. PMID:24409826

  17. 7 CFR 983.42 - Initial members and nomination of successor members.

    Science.gov (United States)

    2010-01-01

    ...) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF... alternate is selected shall serve in place of that member on the committee, and shall have and be able to... members of the committee shall serve for terms of two years: Provided, That four of the initially selected...

  18. The role of peripheral vision in implicit contextual cuing.

    Science.gov (United States)

    van Asselen, Marieke; Castelo-Branco, Miguel

    2009-01-01

    Implicit contextual cuing refers to the ability to learn the association between contextual information of our environment and a specific target, which can be used to guide attention during visual search. It was recently suggested that the storage of a snapshot image of the local context of a target underlies implicit contextual cuing. To make such a snapshot, it is necessary to use peripheral vision. In order to test whether peripheral vision can underlie implicit contextual cuing, we used a covert visual search task, in which participants were required to indicate the orientation of a target stimulus while foveating a fixation cross. The response times were shorter when the configuration of the stimuli was repeated than when the configuration was new. Importantly, this effect was still found after 10 days, indicating that peripherally perceived spatial context information can be stored in memory for long periods of time. These results indicate that peripheral vision can be used to make a snapshot of the local context of a target.

  19. Crossroads between peripheral atherosclerosis, western-type diet and skeletal muscle pathophysiology: emphasis on apolipoprotein E deficiency and peripheral arterial disease.

    Science.gov (United States)

    Sfyri, Peggy; Matsakas, Antonios

    2017-07-08

    Atherosclerosis is a chronic inflammatory process that, in the presence of hyperlipidaemia, promotes the formation of atheromatous plaques in large vessels of the cardiovascular system. It also affects peripheral arteries with major implications for a number of other non-vascular tissues such as the skeletal muscle, the liver and the kidney. The aim of this review is to critically discuss and assimilate current knowledge on the impact of peripheral atherosclerosis and its implications on skeletal muscle homeostasis. Accumulating data suggests that manifestations of peripheral atherosclerosis in skeletal muscle originates in a combination of increased i)-oxidative stress, ii)-inflammation, iii)-mitochondrial deficits, iv)-altered myofibre morphology and fibrosis, v)-chronic ischemia followed by impaired oxygen supply, vi)-reduced capillary density, vii)- proteolysis and viii)-apoptosis. These structural, biochemical and pathophysiological alterations impact on skeletal muscle metabolic and physiologic homeostasis and its capacity to generate force, which further affects the individual's quality of life. Particular emphasis is given on two major areas representing basic and applied science respectively: a)-the abundant evidence from a well-recognised atherogenic model; the Apolipoprotein E deficient mouse and the role of a western-type diet and b)-on skeletal myopathy and oxidative stress-induced myofibre damage from human studies on peripheral arterial disease. A significant source of reactive oxygen species production and oxidative stress in cardiovascular disease is the family of NADPH oxidases that contribute to several pathologies. Finally, strategies targeting NADPH oxidases in skeletal muscle in an attempt to attenuate cellular oxidative stress are highlighted, providing a better understanding of the crossroads between peripheral atherosclerosis and skeletal muscle pathophysiology.

  20. RESTOP: Retaining External Peripheral State in Intermittently-Powered Sensor Systems.

    Science.gov (United States)

    Rodriguez Arreola, Alberto; Balsamo, Domenico; Merrett, Geoff V; Weddell, Alex S

    2018-01-10

    Energy harvesting sensor systems typically incorporate energy buffers (e.g., rechargeable batteries and supercapacitors) to accommodate fluctuations in supply. However, the presence of these elements limits the miniaturization of devices. In recent years, researchers have proposed a new paradigm, transient computing, where systems operate directly from the energy harvesting source and allow computation to span across power cycles, without adding energy buffers. Various transient computing approaches have addressed the challenge of power intermittency by retaining the processor's state using non-volatile memory. However, no generic approach has yet been proposed to retain the state of peripherals external to the processing element. This paper proposes RESTOP, flexible middleware which retains the state of multiple external peripherals that are connected to a computing element (i.e., a microcontroller) through protocols such as SPI or I 2 C. RESTOP acts as an interface between the main application and the peripheral, which keeps a record, at run-time, of the transmitted data in order to restore peripheral configuration after a power interruption. RESTOP is practically implemented and validated using three digitally interfaced peripherals, successfully restoring their configuration after power interruptions, imposing a maximum time overhead of 15% when configuring a peripheral. However, this represents an overhead of only 0.82% during complete execution of our typical sensing application, which is substantially lower than existing approaches.