WorldWideScience

Sample records for peripheral dose measurement

  1. Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Larson, David A.; Zytkovicz, Andrea; Smith, Vernon; Petti, Paula L.

    2008-01-01

    The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT

  2. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  3. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  4. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  5. Measurement of off-axis and peripheral skin dose using radiochromic film

    International Nuclear Information System (INIS)

    Butson, Martin J.; Yu, P.K.N.; Metcalfe, P.E.

    1998-01-01

    A radiotherapy skin dose profile can be obtained with radiochromic film. The central axis skin dose relative to D max for a 10x10cm 2 field size was found to be 22%, 17% and 15.5% for 6 MV, 10 MV and 18 MV photon beams. Peripheral dose increased with increasing field size. At 10 MV the skin dose 2 cm outside the geometric field edge was measured as 6%, 10% and 17% for 10x10cm 2 , 20x20cm 2 and 30x30cm 2 field sizes respectively. Off-axis skin dose decreased as distance increased from central axis for fields with Perspex block trays. For a 20x20cm 2 field, an approximately 5-8% drop in percentage skin dose was observed from central axis to the beam edge. (author)

  6. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks

    International Nuclear Information System (INIS)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters; Silva, Ricardo Goulart da; Viamonte, Alfredo

    2011-01-01

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  7. Peripheral dose in photon beams from a linear accelerator with a multileaf collimator

    International Nuclear Information System (INIS)

    Lope Lope, R.; Lozano Flores, F.; Gracia Sorrosal, J.; Font Gomez, J.A.; Hernandez Vitoria, A.

    2001-01-01

    Radiation doses outside the radiotherapy treatment field are of radiation protection interest when anatomical structures with very low dose tolerances might be involved. One of the major sources of peripheral dose, scatter from secondary collimators, depends on the configuration of the collimator. In this study, peripheral dose was measured at two depths for 6 and 18 MV photons from a linac Primus (Siemens) with a multileaf collimator (MLC). Comparative measurements were made both with leaves and with the upper jaw positioned at the field edge near to the detector. Configuring the MLC leaves at the field edge yielded a reduction in peripheral dose. (author)

  8. Study of the CT peripheral dose variation in a head phantom

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.

    2009-01-01

    The computed tomography is frequently used for the brain diagnosis and it is responsible for the largest doses in the head among the X-ray examinations. Established indexes define a reference dose value for a scan routine; however the dose value has a longitudinal variation in the scan. The purpose of this study is to investigate the variation of the peripheral doses in the head scan using a polymethylmethacrylate head phantom. The studies were performed using two different computed tomography scanners in the option single slice with a routine of a head adult protocol (i.e. default protocol in the scanner software). Radiation doses were measured using thermoluminescent dosimeter (LiF - TLD) rod model, distributed inside the PMMA head phantom in periphery and central area. The results allowed registering the variation dose curve, longitudinally the scan, for the peripheral area and to determine the MSAD value. The peripheral maximum dose value measured can be compared with the maximum dose value in the center of the phantom in each different routine (author)

  9. SU-F-T-473: Evaluation of Off-Axis And Peripheral Dose Using Different Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ganesan, B; Prakasarao, A; Singaravelu, G [Anna University, Chennai, TamilNadu (India); Palraj, T; Rai, R [Dr. Rai Memorial Cancer Institute, Chennai, TamilNadu (India)

    2016-06-15

    Purpose: In radiation therapy, measurement of off-axis and peripheral dose is a tedious task. The dose distribution along the beam central axis give only part of the information required for an accurate dose description inside the patient. Dose distributions in 2-D and 3-D are determined with central axis data in conjunction with off-axis dose profiles. Combining a central axis dose distribution with off-axis data results in volume dose matrix that provides 2-D and 3-D information on dose distribution. By considering the importance of these two parameters this study investigates and compares the off axis and peripheral dose measurement using Ionization chamber, MOSFET, Radiochromic film and EDR2 film. Methods: In the measurement of off-axis and peripheral doses 0.6cc farmer type chamber, EDR-2 film, MD-55 radiochromic film and MOSFET detectors were used for both 6MV and 15MV beams. The off-axis and peripheral dose was measured at every 1 cm interval by changing the position of the couch without disturbing the other experimental setup in particular, the phantom with detector position. Results: Readings were obtained for both 6MV and 15MV photon beams at SSD technique for various field size using MOSFET, Ionization chamber and Radiochromic film. The results shows the percentage difference between various detectors for various field sizes. For Peripheral dose measurement were taken from the edge of the field size and for off axis it is measured form central axis dose. Conclusion: In conclusion, our study shows that no detector is ideal and only a comparison between different detectors highlights the weaknesses of each detector. MOSFET provides adequate dose assessment in off-axis and peripheral regions in 6MV and 15MV photon beams. Film dosimetry in general a convenient method to generate one- and two-dimensional dose distributions. The result of this indicates that MOSFET is flexible tool for relative dosimetry as films.

  10. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks; Doses perifericas de IMRT cranial pediatrica realizada com blocos atenuadores

    Energy Technology Data Exchange (ETDEWEB)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters, E-mail: soboll@utfpr.edu.b, E-mail: iveteschitz@yahoo.com.b, E-mail: schelin@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Silva, Ricardo Goulart da, E-mail: ricardo.goulart@ymail.co [Hospital Angelina Caron, Campina Grande do Sul, PR (Brazil); Viamonte, Alfredo, E-mail: aviamonte@inca.gov.b [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  11. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator

    International Nuclear Information System (INIS)

    Iktueren, B.; Bilge, H.; Karacam, S.; Atkovar, G.

    2012-01-01

    In this study, the peripheral dose outside the applicator was measured using electron beams produced by an Oncor linear accelerator and compared with the data of the treatment planning system (TPS). The dose profiles have been measured, by using a water-equivalent slab phantom and a parallel plate ionisation chamber, at 6, 9 and 15 MeV energy levels in 5 x 5, 10 x 10, 15 x 15, 20 x 20 and 25 x 25 cm 2 applicators and at 0, 10 and 20 deg. gantry angles; and at the surface, 0.2, 0.5, 1 cm and d max depth for each electron energy level. The peripheral dose has been determined with these profiles by normalisation at the field central beam axis (CAX). It has been noticed that, using a 10 x 10 cm 2 applicator, there is a 1.4 % dose peak on the surface 6 cm away from the field edge where the field CAX is at 100 %, at a gantry angle of 0 deg. with 6 and 9 MeV electron beams; also for the 15 MeV electron beam there is a 2.3 % dose peak. It has been discovered that the peak dose approaches a minimum depending on the increase in depth and reaches 2.5-4 % depending on the growth of the field dimension. At gantry angles of 10 and 20 deg., 6 and 9 MeV electron beams created small peaks and a maximum dose could be reached at 0.2 and 1 cm depth. Electron beam of 15 MeV did not peak at depths of 0.2 and 1 cm at gantry angles of 10 and 20 deg.. The measured peripheral dose outside the applicators has been compared with the data from a TPS's computer using the Pencil Beam algorithm; it has been stated that dose calculations can be made as far as 3 cm outside the field. In conclusion, the TPS is not sufficient to measure the peripheral dose outside the applicators, and this dose can only be determined by direct measurement. (authors)

  12. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator.

    Science.gov (United States)

    Iktueren, Basak; Bilge, Hatice; Karacam, Songul; Atkovar, Gulyuz

    2012-06-01

    In this study, the peripheral dose outside the applicator was measured using electron beams produced by an Oncor linear accelerator and compared with the data of the treatment planning system (TPS). The dose profiles have been measured, by using a water-equivalent slab phantom and a parallel plate ionisation chamber, at 6, 9 and 15 MeV energy levels in 5×5, 10×10, 15×15, 20×20 and 25×25 cm(2) applicators and at 0, 10 and 20° gantry angles; and at the surface, 0.2, 0.5, 1 cm and d(max) depth for each electron energy level. The peripheral dose has been determined with these profiles by normalisation at the field central beam axis (CAX). It has been noticed that, using a 10×10 cm(2) applicator, there is a 1.4 % dose peak on the surface 6 cm away from the field edge where the field CAX is at 100 %, at a gantry angle of 0° with 6 and 9 MeV electron beams; also for the 15 MeV electron beam there is a 2.3 % dose peak. It has been discovered that the peak dose approaches a minimum depending on the increase in depth and reaches 2.5-4 % depending on the growth of the field dimension. At gantry angles of 10 and 20°, 6 and 9 MeV electron beams created small peaks and a maximum dose could be reached at 0.2 and 1 cm depth. Electron beam of 15 MeV did not peak at depths of 0.2 and 1 cm at gantry angles of 10 and 20°. The measured peripheral dose outside the applicators has been compared with the data from a TPS's computer using the Pencil Beam algorithm; it has been stated that dose calculations can be made as far as 3 cm outside the field. In conclusion, the TPS is not sufficient to measure the peripheral dose outside the applicators, and this dose can only be determined by direct measurement.

  13. Position displacement effect on the doses in the peripheral head regions

    International Nuclear Information System (INIS)

    Kortesniemi, M.; Seppaelae, T.; Bjugg, H.; Seren, T.; Kotiluoto, P.; Auterinen, I.; Parkkinen, R.; Savolainen, S.

    2000-01-01

    Patient positioning is a challenging task in BNCT-treatments due to the use of multiple fields and a static horizontal beam construction. Positioning accuracy of 5 mm is required for acceptable dose delivery within appropriate limits of dose uncertainty (up to 10% of point dose in target volume). The aim of this study was to determine if a patient head position creating a clear gap between the beam port and the head would have a significant effect on the doses to the peripheral regions of the head, e.g. to the eyes. The gamma dose rates were measured in a water filled ellipsoidal phantom with an ionisation chamber (IC). Mn activation wires were used to determine the Mn-55(n, γ) reaction rates. Twelve measurement points were chosen in the phantom and two phantom positions were applied. According to this study the 35 mm position change and the resulting gap has an obvious effect on the peripheral doses in BNCT. The Mn activation reaction rates were on the average 80% higher in the deviation position than in the reference position. Increasing depth from the surface inside the phantom diminished the gamma dose difference between the two positions. Scattering environment changes with position displacement and resulting gap causes differences in neutron fluences and gamma doses. (author)

  14. Peripheral photon and neutron doses from prostate cancer external beam irradiation.

    Science.gov (United States)

    Bezak, Eva; Takam, Rundgham; Marcu, Loredana G

    2015-12-01

    Peripheral photon and neutron doses from external beam radiotherapy (EBRT) are associated with increased risk of carcinogenesis in the out-of-field organs; thus, dose estimations of secondary radiation are imperative. Peripheral photon and neutron doses from EBRT of prostate carcinoma were measured in Rando phantom. (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescence dosemeters (TLDs) were inserted in slices of a Rando phantom followed by exposure to 80 Gy with 18-MV photon four-field 3D-CRT technique. The TLDs were calibrated using 6- and 18-MV X-ray beam. Neutron dose equivalents measured with CR-39 etch-track detectors were used to derive readout-to-neutron dose conversion factor for (6)LiF:Mg,Cu,P TLDs. Average neutron dose equivalents per 1 Gy of isocentre dose were 3.8±0.9 mSv Gy(-1) for thyroid and 7.0±5.4 mSv Gy(-1) for colon. For photons, the average dose equivalents per 1 Gy of isocentre dose were 0.2±0.1 mSv Gy(-1) for thyroid and 8.1±9.7 mSv Gy(-1) for colon. Paired (6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P TLDs can be used to measure photon and neutron doses simultaneously. Organs in close proximity to target received larger doses from photons than those from neutrons whereas distally located organs received higher neutron versus photon dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET.

    Science.gov (United States)

    Vlachopoulou, Vassiliki; Malatara, Georgia; Delis, Harry; Theodorou, Kiki; Kardamakis, Dimitrios; Panayiotakis, George

    2010-11-28

    To study the peripheral dose (PD) from high-energy photon beams in radiotherapy using the metal oxide semiconductor field effect transistor (MOSFET) dose verification system. The radiation dose absorbed by the MOSFET detector was calculated taking into account the manufacturer's Correction Factor, the Calibration Factor and the threshold voltage shift. PD measurements were carried out for three different field sizes (5 cm × 5 cm, 10 cm × 10 cm and 15 cm × 15 cm) and for various depths with the source to surface distance set at 100 cm. Dose measurements were realized on the central axis and then at distances (1 to 18 cm) parallel to the edge of the field, and were expressed as the percentage PD (% PD) with respect to the maximum dose (d(max)). The accuracy of the results was evaluated with respect to a calibrated 0.3 cm(3) ionization chamber. The reproducibility was expressed in terms of standard deviation (s) and coefficient of variation. % PD is higher near the phantom surface and drops to a minimum at the depth of d(max), and then tends to become constant with depth. Internal scatter radiation is the predominant source of PD and the depth dependence is determined by the attenuation of the primary photons. Closer to the field edge, where internal scatter from the phantom dominates, the % PD increases with depth because the ratio of the scatter to primary increases with depth. A few centimeters away from the field, where collimator scatter and leakage dominate, the % PD decreases with depth, due to attenuation by the water. The % PD decreases almost exponentially with the increase of distance from the field edge. The decrease of the % PD is more than 60% and can reach up to 90% as the measurement point departs from the edge of the field. For a given distance, the % PD is significantly higher for larger field sizes, due to the increase of the scattering volume. Finally, the measured PD obtained with MOSFET is higher than that obtained with an ionization chamber

  16. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    International Nuclear Information System (INIS)

    Vlachopoulou, Vassiliki; Antypas, Christos; Delis, Harry; Tzouras, Argyrios; Salvaras, Nikolaos; Kardamakis, Dimitrios; Panayiotakis, George

    2011-01-01

    Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases

  17. Influence of dose-time relationship on the pathogenesis of peripheral neuropathy

    International Nuclear Information System (INIS)

    Kogelnik, H.D.; Vienna Univ.

    1977-01-01

    The development of peripheral neutopathies of cranial nerves and of the brachial plexus following curative doses of irradiation is closely related with the total dose applied, the number and size of the individual doses per fraction and the overall time. Additional important factors for the occurrence of these late complications are the volume of tissue irradiated and the stage of disease. In the pathogenesis of peripheral neuropathy a combined effect of different factors seems likely. (orig.) [de

  18. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  19. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  20. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    Directory of Open Access Journals (Sweden)

    Vlachopoulou Vassiliki

    2011-11-01

    Full Text Available Abstract Background Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. Methods MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. Results The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Conclusion Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases.

  1. Peripheral doses in modulated intensive radiotherapy (MIRT) and its implications in radiological protection

    International Nuclear Information System (INIS)

    Cobos, Agustin C.; Sanz, Dario E.; Alvarez, Guilhermo D.

    2013-01-01

    A calculation model based on the theory of photon transport, to estimate the peripheral energy fluence (fluence occurring outside the radiation beam) produced by the dispersions of photon compensating filters used was developed in IMRT mode, in a treatment room radiotherapy service of FUESMEN. In order to validate the model were experimentally determined fluences and peripheral dose for three different sizes of compensating filters. It was found that there is a slight systematic overestimation model with respect to experimental results. The experimental values also allowed the comparison of the peripheral doses with other modalities. Furthermore, a model was developed to estimate the annual dose that occurs at any point to be protected with a shield, from the theoretical values obtained from peripheral energy flow. Using the theoretical values automatically allowed to take a conservative approach because of the slight overestimation already mentioned, the couple have a calculation model for widespread use. It was found that the contribution of the peripheral dose to the annual dose is more than significant, thus suggesting that the same should be considered in the design calculations of secondary barriers

  2. Investigation of intracranial peripheral dose arising from the treatment of large lesions with Leksell GammaKnife Perfexion.

    Science.gov (United States)

    Ruschin, Mark; Nordström, Håkan; Kjäll, Per; Cho, Young-Bin; Jaffray, David

    2009-06-01

    This investigation involves quantifying the extent of intracranial peripheral dose arising from simulated targets situated in the skull-base or upper-spine region using the Leksell GammaKnife Perfexion treatment unit. For each of three spherical target volumes--denoted as Vs (4 cm3), VM (18 cm3), and VL (60 cm3)--three treatment plans were manually generated, one for each of the three collimator sizes--4, 8, and 16 mm. Each of the plans was delivered to a spherical dosimetry phantom with an insert containing EBT Gafchromic film. The total dose at 70 mm from the targets' edges, %D(70 mm), was measured as a function of elevation angle and expressed as a percentage of the prescription dose. The film insert was placed centered in the median sagittal plane (Leksell X = 100) and %D(70 mm) was measured for the angular range from 0 degree (superior/along Z axis) to 90 degrees (anterior/along Y axis). For a given collimator i, the irradiation time ti to treat a spherical target of volume V using the 50% isodose line was observed to follow a power-law relationship of the form ti = Ai(V/ Vi)n where Ai was the maximum dose divided by collimator dose rate and Vi was the volume encompassed by the 50% isodose line for a single shot. The mean value of n was 0.61 (range: 0.61-0.62). Along the superior (Z) direction (angle=0 degree) and up to angles of around 30 degrees, the %D(70 mm) was always highest for the 4 mm plans, followed by the 8 mm, followed by the 16 mm. In this angular range, the maximum measured %D(70 mm) was 1.7% of the prescription dose. The intracranial peripheral dose along the superior direction (combined scatter and leakage dose) resulting from irradiation of upper-spine or base-of-skull lesions is measured to be less than 2% of the prescription dose, even for very large (60 cm3) targets. The results of this study indicate that, for a given target volume, treatment plans consisting of only 4 mm shots yield larger peripheral dose in the superior direction than 8

  3. SU-E-T-43: Analytical Model for Photon Peripheral Dose in Radiotherapy Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Nieto, B Sanchez; El far, R [Instituto de Fisica, Pontificia Universidad Catolica de Chile, Santiago, Santiago De Chile (Chile); Romero-Exposito, M [Universitat Autonoma de Barcelona, Barcelona (Spain); Lagares, J [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, Madrid (Spain); Mateo, JC [Hospital Duques del Infantado, Sevilla (Spain); Terron, JA [Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Sevilla (Spain); Irazola, L; Sanchez-Doblado, F [Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Sevilla (Spain); Departamento de Fisiologia Medica y Biofisica, Universidad de Sevilla, Sevilla (Spain)

    2014-06-01

    Purpose: The higher survival rate of radiotherapy patients entails a growing concern on second cancers associated to peripheral doses. Currently, dosimetry of out-of field doses is still under development. Our group has developed a methodology to estimate neutron equivalent dose in organs (1,2). We aimed to propose a model to estimate out-of-field photon doses in isocentric treatments from basic clinical data. Methods: The proposed function models the dose as the sum of leakage and scatter terms. The latter is modeled as a virtual source at the collimator, which suffers from attenuation in air and tissue, corrected by the inverse-square-law. The model was parameterized using experimental measurements with TLD700 chips placed inside an anthropomorphic phantom (6–18MV) irradiated with conformal and modulated techniques in Elekta, Siemens and Varian linacs. This model provides photon dose at a point as a function of clinical parameters as prescription dose/UM, PTV volume, distance to the field edge, height of the MLC leaves and distance from the the MLC to the isocenter. Model was tested against independent measurements (TLD100) for a VMAT treatment on a Elekta. Dose to organs is modeled from dose to points along the head-to-feet axis of the organ of a “standard man” escalated by patient height. Results: Our semi-empirical model depends on 3 given parameters (leakage parameter can be individualized). A novelty of our model, over other models (e.g., PERIDOSE), arises from its applicability to any technique (independently of the number of MU needed to deliver a dose). Differences between predictions and measurements were < 0.005mSv/UM. Conclusion: We have proposed a unique model which successfully account for photon peripheral organ dose. This model can be applied in the day-to-day clinic as it only needs a few basic parameters which are readily accessible.1. Radiother. Oncol. 107:234–243, 2013. 2. Phys. Med. Biol. 57:6167–6191, 2012.

  4. SU-E-T-43: Analytical Model for Photon Peripheral Dose in Radiotherapy Treatments

    International Nuclear Information System (INIS)

    Nieto, B Sanchez; El far, R; Romero-Exposito, M; Lagares, J; Mateo, JC; Terron, JA; Irazola, L; Sanchez-Doblado, F

    2014-01-01

    Purpose: The higher survival rate of radiotherapy patients entails a growing concern on second cancers associated to peripheral doses. Currently, dosimetry of out-of field doses is still under development. Our group has developed a methodology to estimate neutron equivalent dose in organs (1,2). We aimed to propose a model to estimate out-of-field photon doses in isocentric treatments from basic clinical data. Methods: The proposed function models the dose as the sum of leakage and scatter terms. The latter is modeled as a virtual source at the collimator, which suffers from attenuation in air and tissue, corrected by the inverse-square-law. The model was parameterized using experimental measurements with TLD700 chips placed inside an anthropomorphic phantom (6–18MV) irradiated with conformal and modulated techniques in Elekta, Siemens and Varian linacs. This model provides photon dose at a point as a function of clinical parameters as prescription dose/UM, PTV volume, distance to the field edge, height of the MLC leaves and distance from the the MLC to the isocenter. Model was tested against independent measurements (TLD100) for a VMAT treatment on a Elekta. Dose to organs is modeled from dose to points along the head-to-feet axis of the organ of a “standard man” escalated by patient height. Results: Our semi-empirical model depends on 3 given parameters (leakage parameter can be individualized). A novelty of our model, over other models (e.g., PERIDOSE), arises from its applicability to any technique (independently of the number of MU needed to deliver a dose). Differences between predictions and measurements were < 0.005mSv/UM. Conclusion: We have proposed a unique model which successfully account for photon peripheral organ dose. This model can be applied in the day-to-day clinic as it only needs a few basic parameters which are readily accessible.1. Radiother. Oncol. 107:234–243, 2013. 2. Phys. Med. Biol. 57:6167–6191, 2012

  5. Influence of dosing times on cisplatin-induced peripheral neuropathy in rats

    International Nuclear Information System (INIS)

    Seto, Yoshihiro; Okazaki, Fumiyasu; Horikawa, Keiji; Zhang, Jing; Sasaki, Hitoshi; To, Hideto

    2016-01-01

    Although cis-diamminedichloro-platinum (CDDP) exhibits strong therapeutic effects in cancer chemotherapy, its adverse effects such as peripheral neuropathy, nephropathy, and vomiting are dose-limiting factors. Previous studies reported that chronotherapy decreased CDDP-induced nephropathy and vomiting. In the present study, we investigated the influence of dosing times on CDDP-induced peripheral neuropathy in rats. CDDP (4 mg/kg) was administered intravenously at 5:00 or 17:00 every 7 days for 4 weeks to male Sprague–Dawley rats, and saline was given to the control group. To assess the dosing time dependency of peripheral neuropathy, von-Frey test and hot-plate test were performed. In order to estimate hypoalgesia, the hot-plate test was performed in rats administered CDDP weekly for 4 weeks. On day 28, the withdrawal latency to thermal stimulation was significantly prolonged in the 17:00-treated group than in the control and 5:00-treated groups. When the von-Frey test was performed to assess mechanical allodynia, the withdrawal threshold was significantly lower in the 5:00 and 17:00-treated groups than in the control group on day 6 after the first CDDP dose. The 5:00-treated group maintained allodynia throughout the experiment with the repeated administration of CDDP, whereas the 17:00-treated group deteriorated from allodynia to hypoalgesia. It was revealed that the severe of CDDP-induced peripheral neuropathy was inhibited in the 5:00-treated group, whereas CDDP-treated groups exhibited mechanical allodynia. These results suggested that the selection of an optimal dosing time ameliorated CDDP-induced peripheral neuropathy. The online version of this article (doi:10.1186/s12885-016-2777-0) contains supplementary material, which is available to authorized users

  6. A new online detector for estimation of peripheral neutron equivalent dose in organ

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L., E-mail: leticia@us.es; Sanchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009, Spain and Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Lorenzoli, M.; Pola, A. [Departimento di Ingegneria Nuclear, Politecnico di Milano, Milano 20133 (Italy); Bedogni, R. [Laboratori Nazionali di Frascati, Istituto Nazionale di Fisica Nucleare (INFN), Frascati Roma 00044 (Italy); Terrón, J. A. [Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41007 (Spain); Sanchez-Nieto, B. [Instituto de Física, Pontificia Universidad Católica de Chile, Santiago 4880 (Chile); Expósito, M. R. [Departamento de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Lagares, J. I.; Sansaloni, F. [Centro de Investigaciones Energéticas y Medioambientales y Tecnológicas (CIEMAT), Madrid 28040 (Spain)

    2014-11-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  7. A new online detector for estimation of peripheral neutron equivalent dose in organ

    International Nuclear Information System (INIS)

    Irazola, L.; Sanchez-Doblado, F.; Lorenzoli, M.; Pola, A.; Bedogni, R.; Terrón, J. A.; Sanchez-Nieto, B.; Expósito, M. R.; Lagares, J. I.; Sansaloni, F.

    2014-01-01

    Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a fast-growing concern on neutron collateral effects, this work focuses on this component. A previous established methodology to estimate peripheral neutron equivalent doses relied on passive (TLD, CR39) neutron detectors exposed in-phantom, in parallel to an active [static random access memory (SRAMnd)] thermal neutron detector exposed ex-phantom. A newly miniaturized, quick, and reliable active thermal neutron detector (TNRD, Thermal Neutron Rate Detector) was validated for both procedures. This first miniaturized active system eliminates the long postprocessing, required for passive detectors, giving thermal neutron fluences in real time. Methods: To validate TNRD for the established methodology, intrinsic characteristics, characterization of 4 facilities [to correlate monitor value (MU) with risk], and a cohort of 200 real patients (for second cancer risk estimates) were evaluated and compared with the well-established SRAMnd device. Finally, TNRD was compared to TLD pairs for 3 generic radiotherapy treatments through 16 strategic points inside an anthropomorphic phantom. Results: The performed tests indicate similar linear dependence with dose for both detectors, TNRD and SRAMnd, while a slightly better reproducibility has been obtained for TNRD (1.7% vs 2.2%). Risk estimates when delivering 1000 MU are in good agreement between both detectors (mean deviation of TNRD measurements with respect to the ones of SRAMnd is 0.07 cases per 1000, with differences always smaller than 0.08 cases per 1000). As far as the in-phantom measurements are concerned, a mean deviation smaller than 1.7% was obtained. Conclusions: The results obtained indicate that direct evaluation of equivalent dose estimation in organs, both in phantom and patients, is perfectly feasible with this new detector. This will open the door to an

  8. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.

    Science.gov (United States)

    Bourgouin, Alexandra; Varfalvy, Nicolas; Archambault, Louis

    2016-09-08

    Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements were performed with a parallel-plate ion chamber, a small volume ion chamber, and with a PSD. Lateral-dose measurements (LDM) at 0.5 cm depth and depth-dose curve (PDD) were made and compared to the dose calculation provided by a treatment planning system (TPS). This study shows that a PSD can measure a dose as low as 0.51 ± 0.17 cGy for photon beam and 0.58 ± 0.20 cGy for electron beam with a difference of 0.2 and 0.1 cGy compared to a parallel-plate ion chamber. This study demonstrates the potential of using PSD as an out-of-field dosimeter since measure-ments with PSD avoid averaging over a too-large depth, at 1 mm diameter, and can make precise measurement at very low dose. Also, electronic equilibrium is easier to reach with PSD due to its small sensitive volume and its water equivalence. © 2016 The Authors.

  9. Technical Report: Evaluation of peripheral dose for flattening filter free photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Covington, E. L.; Moran, J. M.; Owrangi, A. M.; Prisciandaro, J. I., E-mail: joannp@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Ritter, T. A. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 and Department of Radiation Oncology, Veterans Affairs Ann Arbor Healthcare System, Ann Arbor, Michigan 48105 (United States)

    2016-08-15

    Purpose: To develop a comprehensive peripheral dose (PD) dataset for the two unflattened beams of nominal energy 6 and 10 MV for use in clinical care. Methods: Measurements were made in a 40 × 120 × 20 cm{sup 3} (width × length × depth) stack of solid water using an ionization chamber at varying depths (dmax, 5, and 10 cm), field sizes (3 × 3 to 30 × 30 cm{sup 2}), and distances from the field edge (5–40 cm). The effects of the multileaf collimator (MLC) and collimator rotation were also evaluated for a 10 × 10 cm{sup 2} field. Using the same phantom geometry, the accuracy of the analytic anisotropic algorithm (AAA) and Acuros dose calculation algorithm was assessed and compared to the measured values. Results: The PDs for both the 6 flattening filter free (FFF) and 10 FFF photon beams were found to decrease with increasing distance from the radiation field edge and the decreasing field size. The measured PD was observed to be higher for the 6 FFF than for the 10 FFF for all field sizes and depths. The impact of collimator rotation was not found to be clinically significant when used in conjunction with MLCs. AAA and Acuros algorithms both underestimated the PD with average errors of −13.6% and −7.8%, respectively, for all field sizes and depths at distances of 5 and 10 cm from the field edge, but the average error was found to increase to nearly −69% at greater distances. Conclusions: Given the known inaccuracies of peripheral dose calculations, this comprehensive dataset can be used to estimate the out-of-field dose to regions of interest such as organs at risk, electronic implantable devices, and a fetus. While the impact of collimator rotation was not found to significantly decrease PD when used in conjunction with MLCs, results are expected to be machine model and beam energy dependent. It is not recommended to use a treatment planning system to estimate PD due to the underestimation of the out-of-field dose and the inability to calculate dose

  10. COMPARISON OF THE PERIPHERAL DOSES FROM DIFFERENT IMRT TECHNIQUES FOR PEDIATRIC HEAD AND NECK RADIATION THERAPY.

    Science.gov (United States)

    Toyota, Masahiko; Saigo, Yasumasa; Higuchi, Kenta; Fujimura, Takuya; Koriyama, Chihaya; Yoshiura, Takashi; Akiba, Suminori

    2017-11-01

    Intensity-modulated radiation therapy (IMRT) can deliver high and homogeneous doses to the target area while limiting doses to organs at risk. We used a pediatric phantom to simulate the treatment of a head and neck tumor in a child. The peripheral doses were examined for three different IMRT techniques [dynamic multileaf collimator (DMLC), segmental multileaf collimator (SMLC) and volumetric modulated arc therapy (VMAT)]. Peripheral doses were evaluated taking thyroid, breast, ovary and testis as the points of interest. Doses were determined using a radio-photoluminescence glass dosemeter, and the COMPASS system was used for three-dimensional dose evaluation. VMAT achieved the lowest peripheral doses because it had the highest monitor unit efficiency. However, doses in the vicinity of the irradiated field, i.e. the thyroid, could be relatively high, depending on the VMAT collimator angle. DMLC and SMLC had a large area of relatively high peripheral doses in the breast region. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Does IMRT increase the peripheral radiation dose? A comparison of treatment plans 2000 and 2010

    International Nuclear Information System (INIS)

    Salz, Henning; Eichner, Regina; Wiezorek, Tilo

    2012-01-01

    It has been reported in several papers and textbooks that IMRT treatments increase the peripheral dose in comparison with non-IMRT fields. But in clinical practice not only open fields have been used in the pre-IMRT era, but also fields with physical wedges or composed fields. The aim of this work is to test the hypothesis of increased peripheral dose when IMRT is used compared to standard conformal radiotherapy. Furthermore, the importance of the measured dose differences in clinical practice is discussed and compared with other new technologies for the cases where an increase of the peripheral dose was observed. For cancers of the head and neck, the cervix, the rectum and for the brain irradiation due to acute leukaemia, one to four plans have been calculated with IMRT or conformal standard technique (non-IMRT). In an anthropomorphic phantom the dose at a distance of 30 cm in cranio-caudal direction from the target edge was measured with TLDs using a linear accelerator Oncor registered (Siemens) for both techniques. IMRT was performed using step-and-shoot technique (7 to 11 beams), non-IMRT plans with different techniques. The results depended on the site of irradiation. For head and neck cancers IMRT resulted in an increase of 0.05 - 0.09% of the prescribed total dose (Dptv) or 40 - 70 mGy (Dptv = 65 Gy), compared to non-IMRT technique without wedges or a decrease of 0.16% (approx. 100 mGy) of the prescribed total dose compared to non-IMRT techniques with wedges. For the cervical cancer IMRT resulted in an increased dose in the periphery (+ 0.07% - 0.15% of Dptv or 30 - 70 mGy at Dptv = 45 Gy), for the rectal cancer in a dose reduction (0.21 - 0.26% of Dptv or 100 - 130 mGy at Dptv = 50 Gy) and for the brain irradiation in an increase dose (+ 0.05% of Dptv = 18 Gy or 9 mSv). In summary IMRT does not uniformly cause increased radiation dose in the periphery in the model used. It can be stated that these dose values are smaller than reported in earlier papers

  12. Effects of low-dose continuously fractionated X-ray irradiation on murine peripheral blood lymphocytes

    International Nuclear Information System (INIS)

    Xie Yi; Zhang Hong; Dang Bingrong; Hao Jifang; Guo Hongyun; Wang Xiaohu

    2007-01-01

    For estimating biological risks from low doses continual irradiation, we investigated the effects of exposure to continuously fractionated X-rays on murine immune system. The BALB/c mice were irradiated with 0.07Gy at the first day and 0.08 Gy/d in the following 12 days at a dose rate of 0.2 Gy/min. The peripheral blood lymphocyte cycle and death were determined by flow cytometry at the cumulative doses of 0, 0.07, 0.23, 0.39, 0.55, 0.71, 0.87 and 1.03 Gy respectively. The results showed that the cycle of peripheral blood lymphocyte was arrested in G 0 /G 1 at cumulative doses of 0.07, 0.23, 0.71 and 0.87 Gy, and in G 2 /M at cumulative doses of 0.39 and 1.03 Gy; the percentage of death of peripheral blood lymphocyte was ascended with dose increasing, and reached the death peak at cumulative doses of 0.71 Gy. The results suggested that low doses continual X-rays total-body irradiated could result in changes of cellular cycle and death, and some damages to immunocytes, which accorded to linear square model. (authors)

  13. Cytogenetic Low-Dose Hyperradiosensitivity Is Observed in Human Peripheral Blood Lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Seth, Isheeta [Department of Biological Sciences, Wayne State University, Detroit, Michigan (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, Michigan (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, Michigan (United States)

    2015-01-01

    Purpose: The shape of the ionizing radiation response curve at very low doses has been the subject of considerable debate. Linear-no-threshold (LNT) models are widely used to estimate risks associated with low-dose exposures. However, the low-dose hyperradiosensitivity (HRS) phenomenon, in which cells are especially sensitive at low doses but then show increased radioresistance at higher doses, provides evidence of nonlinearity in the low-dose region. HRS is more prominent in the G2 phase of the cell cycle than in the G0/G1 or S phases. Here we provide the first cytogenetic mechanistic evidence of low-dose HRS in human peripheral blood lymphocytes using structural chromosomal aberrations. Methods and Materials: Human peripheral blood lymphocytes from 2 normal healthy female donors were acutely exposed to cobalt 60 γ rays in either G0 or G2 using closely spaced doses ranging from 0 to 1.5 Gy. Structural chromosomal aberrations were enumerated, and the slopes of the regression lines at low doses (0-0.4 Gy) were compared with doses of 0.5 Gy and above. Results: HRS was clearly evident in both donors for cells irradiated in G2. No HRS was observed in cells irradiated in G0. The radiation effect per unit dose was 2.5- to 3.5-fold higher for doses ≤0.4 Gy than for doses >0.5 Gy. Conclusions: These data provide the first cytogenetic evidence for the existence of HRS in human cells irradiated in G2 and suggest that LNT models may not always be optimal for making radiation risk assessments at low doses.

  14. Evaluation of patients radiation dose from computed tomography during lower peripheral angiography procedure

    International Nuclear Information System (INIS)

    Khlafallah, Leena Ahmed Ali

    2015-09-01

    The purpose of this study was to evaluate patient radiation doses in lower peripheral angiography CT examinations in Sudan. Survey was conducted in four major hospitals which almost carry out lower peripheral angiography procedures in Sudan at the time of study. All hospitals were equipped with 64 slices multi detectors CT from Toshiba (Japan). The total number of patients was 74. Information on patient's genders and ages, exposure technique factors and radiation dose were collected. The procedures performed in multi phases, up to five phases covering part of the abdomen region, which can make patients exposure reasonably high. CTDI values in the different phases ranged between (13-30) mGy. The total DLP in the four hospitals were 6888.75, 5065.05, 6608.88 and 5754.9 mGy.cm. This study provided first survey for patient dose during lower peripheral angiography procedures in Sudan. Taking into account that the CT machines were similar: the variation between patient's DLP and CTDI values in the different hospitals indicated the need of optimization of radiation protection. Staff training and awareness on factors affecting patient dose are essential.(Author)

  15. Effects of long-term, low dose rate fission neutron irradiation on the peripheral hematological cells in rats

    International Nuclear Information System (INIS)

    Jiang Dingwen; Lei Chengxiang; Shen Xianrong; Ma Li; Yang Xufang; Peng Wulin; Dai Shourong

    2008-01-01

    Objective: To evaluate the effects of long-term, low dose rate fission neutron irradiation on the peripheral hematological cells in rats. Methods: 96 rats were randomly divided into the control group and the irradiation group with low dose rate fission neutron ( 252 Cf, 0.35 mGy/h) irradiation 20.5 h every day. 8 rats of each group were killed at 14 d, 28 d, 42d, 56d, 70d after irradiation and 35d after the irradiation, and their peripheral hematological cells were tested respectively. Results: Compared with the control group, peripheral blood WBC was reduced significantly at the dose of 0.3Gy and 0.4Gy (P < 0.05), and was reduced remarkably at dose of 0.5Gy (P<0.01) and 35d after stopping irradiation(P<0.01). At dose of 0.2Gy, Peripheral blood RBC was abnormally higher comparing with the control group (P<0.01), accompanying with higher HCT and HGB, which suggests condensed blood. At the other point, RBC tend to become lower, but only at dose 0.5Gy, and the difference is significant comparing with control group(P <0.05). At dose of 0.3Gy, 0.4Gy and 0.5Gy, HCT were significantly lower comparing with control group. Comparing with control group, MCV was higher at 35d after stopping irradiation, and PLT was significantly lower in dose of 0.2Gy. Conclusion: Long-term irradiation with low dose rate fission neutron could significantly reduce peripheral blood WBC, with less effects on RBC and PLT. The reduced WBC could not recover at 35d after stopping irradiation. (authors)

  16. Radiation therapy for stage IIA and IIB testicular seminoma: peripheral dose calculations and risk assessments

    Science.gov (United States)

    Mazonakis, Michalis; Berris, Theocharris; Lyraraki, Efrossyni; Damilakis, John

    2015-03-01

    This study was conducted to calculate the peripheral dose to critical structures and assess the radiation risks from modern radiotherapy for stage IIA/IIB testicular seminoma. A Monte Carlo code was used for treatment simulation on a computational phantom representing an average adult. The initial treatment phase involved anteroposterior and posteroanaterior modified dog-leg fields exposing para-aortic and ipsilateral iliac lymph nodes followed by a cone-down phase for nodal mass irradiation. Peripheral doses were calculated using different modified dog-leg field dimensions and an extended conventional dog-leg portal. The risk models of the BEIR-VII report and ICRP-103 were combined with dosimetric calculations to estimate the probability of developing stochastic effects. Radiotherapy for stage IIA seminoma with a target dose of 30 Gy resulted in a range of 23.0-603.7 mGy to non-targeted peripheral tissues and organs. The corresponding range for treatment of stage IIB disease to a cumulative dose of 36 Gy was 24.2-633.9 mGy. A dose variation of less than 13% was found by altering the field dimensions. Radiotherapy with the conventional instead of the modern modified dog-leg field increased the peripheral dose up to 8.2 times. The calculated heart doses of 589.0-632.9 mGy may increase the risk for developing cardiovascular diseases whereas the testicular dose of more than 231.9 mGy may lead to a temporary infertility. The probability of birth abnormalities in the offspring of cancer survivors was below 0.13% which is much lower than the spontaneous mutation rate. Abdominoplevic irradiation may increase the lifetime intrinsic risk for the induction of secondary malignancies by 0.6-3.9% depending upon the site of interest, patient’s age and tumor dose. Radiotherapy for stage IIA/IIB seminoma with restricted fields and low doses is associated with an increased morbidity. These data may allow the definition of a risk-adapted follow-up scheme for long

  17. High-dose thalidomide increases the risk of peripheral neuropathy in the treatment of ankylosing spondylitis

    Directory of Open Access Journals (Sweden)

    Hong-xia Xue

    2015-01-01

    Full Text Available Thalidomide is an effective drug for the treatment of ankylosing spondylitis but might induce peripheral neuropathy. This major adverse reaction has attracted much concern. The current study aimed to observe the incidence of thalidomide-induced peripheral neuropathy among ankylosing spondylitis patients for 1 year after treatment. In this study, 207 ankylosing spondylitis cases received thalidomide treatment, while 116 ankylosing spondylitis cases received other treatments. Results showed that the incidence of thalidomide-induced peripheral neuropathy in the thalidomide group was higher than that in the non-thalidomide group. There was no significant difference in the incidence of neuropathy between the < 6 months medication and ≥ 6 months medication groups. There were no differences in the mean age, gender, or daily dose between the two groups. The incidence of peripheral neuropathy among patients receiving 25, 50, 75, or 100 mg thalidomide per day was 4.6%, 8.5%, 17.1%, 21.7%, respectively. The incidence was significantly different between the groups receiving 25 mg and 100 mg thalidomide. In conclusion, thalidomide can induce peripheral neuropathy within 1 year after treatment of ankylosing spondylitis; however, age and gender have no obvious impact on the incidence of peripheral neuropathy. The incidence of peripheral neuropathy is associated with increasing daily doses of thalidomide.

  18. SU-E-T-611: Photon and Neutron Peripheral Dose Ratio for Low (6 MV) and High (15 MV) Energy for Treatment Selection

    Energy Technology Data Exchange (ETDEWEB)

    Irazola, L; Sanchez-Doblado, F [Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Terron, J; Ortiz-Seidel, M [Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Seville (Spain); Departamento de Fisiologia Medica y Biofisica, Universidad de Seville (Spain); Sanchez-Nieto, B [Instituto de Fisica, Pontificia Universidad Catolica de Chile, Santiago (Chile)

    2015-06-15

    Purpose: Differences between radiotherapy techniques and energies, can offer improvements in tumor coverage and organs at risk preservation. However, a more complete decision should include peripheral doses delivered to the patient. The purpose of this work is the balance of photon and neutron peripheral doses for a prostate case solved with 6 different treatment modalities. Methods: Inverse and Forward IMRT and 3D-CRT in 6 and 15 MV for a Siemens Primus linac, using the same CT data set and contours. The methodology described in [1], was used with the TNRD thermal neutron detector [2] for neutron peripheral dose estimation at 7 relevant organs (colon, esophagus, stomach, liver, lung, thyroid and skin). Photon doses were estimated for these organs by terms of the algorithm proposed in [3]. Plans were optimized with the same restrictions and limited to 30 segments in the Inverse case. Results: A similar photon peripheral dose was found comparing 6 and 15 MV cases with slightly higher values of (1.9 ± 1.6) % in mean, for the 6 MV cases. Neutron presence when using 15 MV, represents an increase in peripheral dose of (18 ± 17) % in average. Due to the higher number of MU used in Inverse IMRT, an increasing of (22 ± 3) % in neutron dose is found related to Forward and 3D-CRT plans. This corresponds to photon doses within 44 and 255 mSv along the organs, for a dose prescription of 68 Gy at the isocenter. Conclusion: Neutron and photon peripheral doses for a prostate treatment planified in 6 different techniques have been analyzed. 6 MV plans are slightly more demanding in terms of photon peripheral doses. Inverse technique in 15 MV has Result to be the most demanding one in terms of total peripheral doses, including neutrons and photons.

  19. Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    Science.gov (United States)

    Yeboah, Collins; Karotki, Alex; Hunt, Dylan; Holly, Rick

    2010-06-15

    In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height along applicator and of lateral distance from applicator body. Relative to central-axis ionization maximum in solid water, the maximum leakage in air observed with a cylindrical ion chamber with 1 cm solid water buildup cap at a lateral distance of 2 cm from the front and right sidewalls of applicators were 17% and 14%, respectively; these maxima were recorded for 18 MeV electron beams and applicator sizes of >or=20 x 20 cm2. In the patient plane, the applicator leakage gave rise to a broad peripheral dose off-axis distance peak that shifted closer to the field edge as the electron energy increases. The maximum peripheral dose from normally incident primary electron beams at a depth of 1 cm in a water phantom was observed to be equal to 5% of the central-axis dose maximum and as high as 9% for obliquely incident beams with angles of obliquity dose curves showed that the "practical range" of the leakage electrons in water varies from approximately 1.4 to 5.7 cm as the primary electron beam energy is raised from 6 to 18 MeV. Next, transmission measurements of leakage radiation through the shielding material Xenolite-NL showed a 4 mm thick sheet of this material is required to attenuate the leakage from 9 MeV beams by two-thirds, and that for every additional 3 MeV increase in the primary electron beam energy, an additional Xenolite-NL thickness of roughly 2 mm is needed to achieve the aforementioned attenuation level. Finally, attachment of a 1 mm thick sheet of lead to the outer surface of applicator sidewalls resulted in a reduction of the peripheral dose by up to 80% and 74% for 9 and 18MeV beams, respectively. This sidewall modification had an

  20. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    International Nuclear Information System (INIS)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.; Anderson, W.; Terrill, R.; Sindelar, W.F.

    1991-01-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers and perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy

  1. Low-dose radiation (LDR) induces hematopoietic hormesis: LDR-induced mobilization of hematopoietic progenitor cells into peripheral blood circulation.

    Science.gov (United States)

    Li, Wei; Wang, Guanjun; Cui, Jiuwei; Xue, Lu; Cai, Lu

    2004-11-01

    The aim of this study was to investigate the stimulating effect of low-dose radiation (LDR) on bone marrow hematopoietic progenitor cell (HPC) proliferation and peripheral blood mobilization. Mice were exposed to 25- to 100-mGy x-rays. Bone marrow and peripheral blood HPCs (BFU-E, CFU-GM, and c-kit+ cells) were measured, and GM-CSF, G-CSF, and IL-3 protein and mRNA expression were detected using ELISA, slot blot hybridization, and Northern blot methods. To functionally evaluate LDR-stimulated and -mobilized HPCs, repopulation of peripheral blood cells in lethally irradiated recipients after transplantation of LDR-treated donor HPCs was examined by WBC counts, animal survival, and colony-forming units in the recipient spleens (CFUs-S). 75-mGy x-rays induced a maximal stimulation for bone marrow HPC proliferation (CFU-GM and BFU-E formation) 48 hours postirradiation, along with a significant increase in HPC mobilization into peripheral blood 48 to 72 hours postradiation, as shown by increases in CFU-GM formation and proportion of c-kit+ cells in the peripheral mononuclear cells. 75-mGy x-rays also maximally induced increases in G-CSF and GM-CSF mRNA expression in splenocytes and levels of serum GM-CSF. To define the critical role of these hematopoietic-stimulating factors in HPC peripheral mobilization, direct administration of G-CSF at a dose of 300 microg/kg/day or 150 microg/kg/day was applied and found to significantly stimulate GM-CFU formation and increase c-kit+ cells in the peripheral mononuclear cells. More importantly, 75-mGy x-rays plus 150 microg/kg/day G-CSF (LDR/150-G-CSF) produced a similar effect to that of 300 microg/kg/day G-CSF alone. Furthermore, the capability of LDR-mobilized donor HPCs to repopulate blood cells was confirmed in lethally irradiated recipient mice by counting peripheral WBC and CFUs-S. These results suggest that LDR induces hematopoietic hormesis, as demonstrated by HPC proliferation and peripheral mobilization, providing a

  2. The DNA damage of high doses of X-ray on human peripheral blood nucleated cell's and sperm

    International Nuclear Information System (INIS)

    Wang Hui; Zoulian; Jiang Qisheng; Li Fengsheng; He Rui; Song Xiujun

    2011-01-01

    Objective: To detect the DNA damage of high doses of X-ray on human peripheral blood nucleated cell's and sperm by single cell gel electrophoresis (SCGE). Evaluation the level of DNA damage of human peripheral blood nucleated cell's and sperm after high doses of X-ray. Methods: Using human peripheral blood with normal blood routine and normal sperm,give the dose of 0 Gy, 2 Gy, 4 Gy, 6 Gy, 8 Gy, 10 Gy X-ray radiation with energy of 6MU. Detect the percentage of comet-like tail, tail length and content of DNA in tail of whole blood cell's DNA and sperm's DNA by SCGE technique in 1 hour. Results: The peripheral blood nucleated cell's and sperm's comet rate were 1.00±0.10%, 2.1±1.5%, respectively, have an evidently variance in 0 Gy group (υ=18, t=2.31>1.734, P 1.734, P 1.734, P<0.05). The peripheral blood nucleated cell's and sperm's comet rate were all 100%, 100%, have no-statistical significance in 8 Gy, 10 Gy group. Conclusion: The evidence is powerful enough. That the sperm's SCGE is more sensitive than peripheral blood nucleated cell's SCGE in reflect the X-ray damage in a certain extent (2-6 Gy). (authors)

  3. Radiosensitizing activity and pharmacokinetics of multiple dose administered KU-2285 in peripheral nerve tissue in mice

    International Nuclear Information System (INIS)

    Iwai, Hiroyuki; Matsuno, Etsuko; Sasai, Keisuke; Abe, Mitsuyuki; Shibamoto, Yuta

    1994-01-01

    In a clinical trial in which a 2-nitroimidazole radiosensitizer was administered repeatedly, the dose-limiting toxicity was found to be peripheral neuropathy. In the present study, the in vivo radiosensitizing activity of KU-2285 in combination with radiation dose fractionation, and the pharmacokinetics of cumulative dosing of KU-2285 in the peripheral nerves were examined. The ability of three nitroimidazoles, misonidazole (MISO), etanidazole (SR-2508) and KU-2285, to sensitize SCCVII tumors to radiation treatment has been compared for drug doses in the range 0-200 mg/kg. Single radiation doses or two different fractionation schedules (6 Gy/fractions x three fractions/48 h or 5 Gy/fractions x five fractions/48 h) were used; the tumor cell survival was determined using an in vivo/in vitro colony assay. The pharmacokinetics in the sciatic nerves were undertaken, when KU-2285 or etanidazole were injected at a dose of 200 mg/kg intravenously one, two, three, or four times at 2-h intervals. At less than 100 mg/kg, KU-2285 sensitized SCCVII tumors more than MISO and SR-2508 by fractionated irradiation. Evaluation of pharmacokinetics in the peripheral nerves showed that the apparent biological half-life of SR-2508 increased with the increases in the number of administrations, whereas that of KU-2285 became shorter. Since most clinical radiotherapy is given in small multiple fractions, KU-2285 appears to be a hypoxic cell radiosensitizer that could be useful in such regimens, and that poses no risk of chronic peripheral neurotoxicity. 12 refs., 5 figs., 1 tab

  4. Effects of low dose rate fission neutron irradiation on the lymphocyte subpopulations of peripheral blood in rats

    International Nuclear Information System (INIS)

    Jiang Dingwen; Lei Chengxiang; Shen Xianrong; Ma Li; Yang Yifang; Peng Wulin; Dai Shourong

    2008-01-01

    Objective: To evaluate the effects of long-term, low dose rate fission neutron irradiation on lymphocyte subpopulations in peripheral blood of rats. Methods: Ninety-six rats were randomly divided into control group and irradiated group exposed to low dose rate fission neutron ( 252 Cf,0.35 mGy/h) for 20.5 h every day. At days 14,28,42,56 and 70 d after irradiation and 35 d after stopping irradiation, After 8 rats of each group were killed, WBC and lymphocyte subpopulations of CD4 + CD3 + , CD8 + CD3 + and CD45RA + /CD161α + in peripheral blood were estimated respectively. Results: Compared with the control group, WBC was reduced significantly at dose of 0.3, 0.4 and 0.5 Gy (P + CD3 - was evidently higher compared with control group at doses of 0.1,0.3, 0.4 and 0.5 Gy and 35 d after stopping irradiation (P + CD3 - was obviously higher compared with control group at dose of 0.2 and 0.3 Gy (P + CD3 + at dose of 0.1 Gy (P + CD3 + at doses of 0.1 and 0.2 Gy (P + CD45RA - ) was increased significantly at doses of 0.2-0.3 Gy, and peripheral blood B cells(CD161α - CD45RA + ) was reduced remarkably at doses of 0.1-0.5 Gy and 35 d after stopping irradiation compared with the control group. Conclusions: Long-term irradiation with low dose rate fission neutron could make TCR (T-cell-receptor) mutant, therefore, WBC, B cells in peripheral blood significantly reduced and NK cells increased. These changes may could not recover at 35 d after Stopping irradiation. (authors)

  5. Peripheral dose measurements with diode and thermoluminescence dosimeters for intensity modulated radiotherapy delivered with conventional and un-conventional linear accelerator

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh; Tambe, Chandrashekhar; Kadam, Sudarshan; Deshpande, Deepak; Gamre, Poonam; Biju, George; Suryaprakash; Magai, C.S.; Shrivastava, Shyam; Dhote, Dipak

    2013-01-01

    The objective of this paper was to measure the peripheral dose (PD) with diode and thermoluminescence dosimeter (TLD) for intensity modulated radiotherapy (IMRT) with linear accelerator (conventional LINAC), and tomotherapy (novel LINAC). Ten patients each were selected from Trilogy dual-energy and from Hi-Art II tomotherapy. Two diodes were kept at 20 and 25 cm from treatment field edge. TLDs (LiF:MgTi) were also kept at same distance. TLDs were also kept at 5, 10, and 15 cm from field edge. The TLDs were read with REXON reader. The readings at the respective distance were recorded for both diode and TLD. The PD was estimated by taking the ratio of measured dose at the particular distance to the prescription dose. PD was then compared with diode and TLD for LINAC and tomotherapy. Mean PD for LINAC with TLD and diode was 2.52 cGy (SD 0.69), 2.07 cGy (SD 0.88) at 20 cm, respectively, while at 25 cm, it was 1.94 cGy (SD 0.58) and 1.5 cGy (SD 0.75), respectively. Mean PD for tomotherapy with TLD and diode was 1.681 cGy (SD 0.53) and 1.58 (SD 0.44) at 20 cm, respectively. The PD was 1.24 cGy (SD 0.42) and 1.088 cGy (SD 0.35) at 25 cm, respectively, for tomotherapy. Overall, PD from tomotherapy was found lower than LINAC by the factor of 1.2-1.5 PD measurement is essential to find out the potential of secondary cancer. PD for both (conventional LINAC) and novel LINACs (tomotherapy) were measured and compared with each other. The comparison of the values for PD presented in this work and those published in the literature is difficult because of the different experimental conditions. The diode and TLD readings were reproducible and both the detector readings were comparable. (author)

  6. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose-effect curve)

    International Nuclear Information System (INIS)

    Al-Achkar, W.

    2001-09-01

    In order to draw a dose-effect curve, experimentally gamma ray induced chromosomal aberrations in human peripheral lymphocytes from eight healthy people were studied. Samples from 4 males and 4 females were irradiated in tubes with 0.15, 0.25, 0.5, 1, 1.5, 2, 2.5 gray of gamma ray (Co 60 at dose rate 0.3 Gy/min). Irradiated and control samples were incubated in 37 centigrade for 48 hours cell cultures. Cell cultures then were stopped and metaphases spread, Giemsa stained to score the induced chromosomal aberrations. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics + rings and total numbers of breaks in cell for each individual or for all people were drawn. An increase of all chromosomal aberrations types with the elevation of the doses was observed. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  7. The software program Peridose to calculate the fetal dose or dose to other critical structures outside the target area in radiation therapy

    International Nuclear Information System (INIS)

    Giessen, P.H. van der

    2001-01-01

    An accurate estimate of the dose outside the target area is of utmost importance when pregnant patients have to undergo radiotherapy, something that occurs in every radiotherapy department once in a while. Such peripheral doses (PD) are also of interest for late effects risk estimations for doses to specific organs as well as estimations of dose to pacemakers. A software program, Peridose, is described to allow easy calculation of this peripheral dose. The calculation is based on data from many publications on peripheral dose measurements, including those by the author. Clinical measurements have shown that by using data averaged over many measurements and different machine types PDs can be estimated with an accuracy of ± 60% (2 standard deviations). The program allows easy and fairly accurate estimates of peripheral doses in patients. Further development to overcome some of the constraints and limitations is desirable. The use of average data is to be preferred if general applicability is to be maintained. (author)

  8. Prostaglandin E1 in conjunction with high doses of vitamin B12 improves nerve conduction velocity of patients with diabetic peripheral neuropathy

    Institute of Scientific and Technical Information of China (English)

    Jilai Li; Zhirong Wan

    2008-01-01

    BACKGROUND: Prostaglandin E1 improves diabetic peripheral neuropathy in symptoms and sensory threshold. Vitamin B1 and methyl-vitamin B12 improve microcirculation to peripheral nerve tissue and promote neurotrophy.OBJECTIVE: To observe motor nerve and sensory nerve conduction velocity in patients with diabetic peripheral neuropathy, prior to and after treatment with prostaglandin E1, vitamin B1 and different doses of vitamin B12.DESIGN, TIME AND SETTING: Randomized, controlled experiment, performed at the Department of Neurology. Beijing Hantian Central Hospital, between February 2002 and September 2007.PARTICIPANTS: A total of 122 patients with type 2 diabetic peripheral neuropathy; 73 males and 49 females were included. All patients met the diagnostic criteria of diabetes mellitus, as determined by the World Health Organization in 1999 and 2006, and also the diagnostic criteria of diabetic peripheral neuropathy. For each subject, conduction disorders in the median nerve and in the common peroneal nerve were observed using electromyogram. Also, after diet and drug treatment, the blood glucose level of subjects was observed to be at a satisfactory level for more than two weeks, and the symptoms of diabetic peripheral neuropathy were not alleviated.METHODS: All patients were randomly divided into the following three groups. A control group (n=40), in which, 100mg vitamin B1 and 500μg vitamin B12 were intramuscularly injected. A vitamin B12 low-dose treated group (n=42), in which 10μg prostaglandin E1 in 250mL physiological saline was intravenously injected once a day and 100mg vitamin B1 and 500μg vitamin B12 was intramuscularly injected once a day. Lastly, a vitamin B12 high-dose treated group (n=40), in which administration was the same as in the vitamin B12 low-dose treated group, except that 500μg vitamin B12 was replaced by 1mg vitamin B12. Administration was performed for four weeks for each group.MAIN OUTCOME MEASURES: The motor nerve and sensory nerve

  9. High dose stainless steel swelling data on interior and peripheral oxide fuel pins

    International Nuclear Information System (INIS)

    Boltax, A.; Foster, J.P.; Nayak, U.P.

    1983-01-01

    High dose (2 x 10 23 n/cm 2 , E > 0.1 Mev) swelling data obtained on 20% cold-worked AISI 316 stainless steel (N-lot) cladding from mixed-oxide fuel pins show large differences in swelling incubation dose due to pre-incubation dose temperature changes. Circumferential swelling variations of 1.5 to 4 times were found in peripheral fuel pin cladding which experienced 30 to 60 deg C temperature changes due to movement in a temperature gradient. Consideration is given to the implications of these results to low swelling materials development and core design. (author)

  10. High-dose thalidomide increases the risk of peripheral neuropathy in the treatment of ankylosing spondylitis.

    Science.gov (United States)

    Xue, Hong-Xia; Fu, Wen-Yi; Cui, Hua-Dong; Yang, Li-Li; Zhang, Ning; Zhao, Li-Juan

    2015-05-01

    Thalidomide is an effective drug for the treatment of ankylosing spondylitis but might induce peripheral neuropathy. This major adverse reaction has attracted much concern. The current study aimed to observe the incidence of thalidomide-induced peripheral neuropathy among ankylosing spondylitis patients for 1 year after treatment. In this study, 207 ankylosing spondylitis cases received thalidomide treatment, while 116 ankylosing spondylitis cases received other treatments. Results showed that the incidence of thalidomide-induced peripheral neuropathy in the thalidomide group was higher than that in the non-thalidomide group. There was no significant difference in the incidence of neuropathy between the peripheral neuropathy among patients receiving 25, 50, 75, or 100 mg thalidomide per day was 4.6%, 8.5%, 17.1%, 21.7%, respectively. The incidence was significantly different between the groups receiving 25 mg and 100 mg thalidomide. In conclusion, thalidomide can induce peripheral neuropathy within 1 year after treatment of ankylosing spondylitis; however, age and gender have no obvious impact on the incidence of peripheral neuropathy. The incidence of peripheral neuropathy is associated with increasing daily doses of thalidomide.

  11. A dose-effect curve of premature condensation chromosome ring in lymphocytes of human peripheral blood exposed to high dose of 60Co γ-rays in vitro

    International Nuclear Information System (INIS)

    Yao Bo; Li Yufang; Liu Guangxian; Huang Shan; Jiang Benrong; Ai Huisheng

    2009-01-01

    Objective: To establish a dose-effect curve of premature condensation chromosome ring (PCC-R) in lymphocytes of human peripheral blood after exposed to high doses of γ-rays. Methods: Peripheral blood samples was drawn from three healthy individuals, and exposed to 60 Co γ-rays with doses between 0 and 30 Gy. The frequencies of PCC-R in premature condensation chromosome (PCC) cells obtained by Okadaic acid (OA) induction were calculated, and a dose-effect curve was fitted. Results: PCC index tapered with dose. Frequencies of PCC-R per cell increased until 20 Gy, and then saturation was observed. The results were fitted to a lineal model up to 20 Gy: y=-0.020 + 0.052D, where y was the frequencies of PCC-R per cell, D was the radiation dose(Gy). Conclusions: The highest dose could be estimated is 20 Gy by the dose-effect curve established with PCC-R method. Its utility and validity will be verified in the future application of radiation accident. (authors)

  12. In vivo measurement of urethral dose profiles

    International Nuclear Information System (INIS)

    Toye, W.C.; Royal Melbourne Institute of Technology,; Duchesne, G.M.; Das, K.R.; Cee, A.; Mameghan, H.; Johnston, P.N.

    2001-01-01

    Full text: Quality assurance becomes a critical requirement when radiographs are routinely used in planning of treatments. In HDR prostate brachytherapy, the surrounding organs at risk of complications are the bladder and the rectum. However, of particular concern is the urethra that runs centrally through the prostate gland, as an unavoidably high dose can occur in the central region in order to achieve a minimum peripheral dose to a small target volume. Although high urethral doses have previously been related to increased urinary symptoms, some recent studies have not found such a correlation. The aim of this study was firstly, to identify dosimetric indicators of urethral morbidity following HDR prostate brachytherapy (4F x of 5.0 Gy), and secondly, to test the validity of calculated dose values. The in vivo measurements utilised a TLD (LiF:Mg,Ti) train formed by loading eight TLD rods alternating with 1,0 cm brass spacers into a fine plastic flexible tube. The length and diameter of plastic tubing was approximately 45cm and 0.15cm respectively, while the train length was 11.8 cm from the tip of the tube. The TLD train was placed into the central lumen of an 18 F three-way urethral catheter prior to its insertion. Significant urinary morbidity was defined prospectively as a score of a total of 3 or more points for severity from 5 symptoms categories. The five symptoms evaluated were hesitancy, frequency/nocturia, dysuria, haematuria and incontinence. The introduction of in vivo measurements to enhance the existing dosimetric analysis may be required to fully test the quantitative relationships (e.g. dose-volume ratios). Placement of TLDs within the urethra results in measurements whose accuracy is unaffected by internal organ motion as the hollow urethra must move with the prostate. The dose recorded by the TLDs is determined independently of the predictive algorithm used by the treatment planning system, and prostate location errors (e.g. due to image

  13. Dose response relationships and analysis of primary processes of radiation-induced chromosomal aberrations in human peripheral lymphocytes

    International Nuclear Information System (INIS)

    Schmid, E.

    1977-02-01

    Human peripheral lymphocytes were irradiated with 220 kV X-rays, 3 MeV electrons and 15 MeV neutrons. The frequency of dicentric, acentric and atypical chromosomes and the exhange aberrations were measured and dose effect curves were constructed. The aim is to prepare the chromosome analysis to a biological dosimetry. The aberration findings could be adapted to the linear-quadrativ model y = c+ αD + βD 2 . With increasing LET the quantity lambda increased which is a measure for the share of the linear and quadratical components of the dose effect obtained. In case of electrons the RBE-values increased with increasing doses. In the case of neutrons they had their maximum in the low dose range. The feed back distances which lead to formation of primary lesions are for X-rays and electrons approximately 1 μm, for neutrons 1.7 μm. In a fractionation experiment with X-rays, the time of formation of exchange aberrations in radiation-induced primary breaks was measured. The number of dicentric chromosomes decreased with increasing time, while the intercellular distribution was not changed. The number of primary breaks decreasing per temporal interval is proportional to the number of the existing primary breaks. The average feed back time during which the primary breaks lead to induction of dicentric chromosomes, is 110 min. In order to determine the correspondence of the results of in-vivo and in-vitro experiments 15 patients and their blood were irradiated with 60 C-γ-rays. No significant differences were measured. (AJ) [de

  14. Liposomal bupivacaine as a single-injection peripheral nerve block: a dose-response study.

    Science.gov (United States)

    Ilfeld, Brian M; Malhotra, Nisha; Furnish, Timothy J; Donohue, Michael C; Madison, Sarah J

    2013-11-01

    Currently available local anesthetics approved for single-injection peripheral nerve blocks have a maximum duration of fashion. The end points included the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle and tolerance to cutaneous electrical current in the femoral nerve distribution. Measurements were performed from baseline until quadriceps MVIC returned to 80% of baseline bilaterally. There were statistically significant dose responses in MVIC (0.09%/mg, SE = 0.03, 95% confidence interval [CI], 0.04-0.14, P = 0.002) and tolerance to cutaneous current (-0.03 mA/mg, SE = 0.01, 95% CI, -0.04 to -0.02, P 40 mg, tolerance to cutaneous current did not return to within 20% above baseline until after 24 hours in 100% of subjects (95% CI, 56%-100%). MVIC did not consistently return to within 20% of baseline until after 24 hours in 90% of subjects (95% CI, 54%-100%). Motor block duration was not correlated with bupivacaine dose (0.06 hour/mg, SE = 0.14, 95% CI, -0.27 to 0.39, P = 0.707). The results of this investigation suggest that deposition of a liposomal bupivacaine formulation adjacent to the femoral nerve results in a partial sensory and motor block of >24 hours for the highest doses examined. However, the high variability of block magnitude among subjects and inverse relationship of dose and response magnitude attests to the need for a phase 3 study with a far larger sample size, and that these results should be viewed as suggestive, requiring confirmation in a future trial.

  15. IMRT in a pregnant patient: how to reduce the fetal dose?

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Nyström, Håkan; Kjaer-Kristoffersen, Flemming

    2008-01-01

    dose distribution. The peripheral dose originating from the final IMRT plan was measured at distances reaching from the most proximal to the most distal fetal position, along the accelerator's longitudinal axis, using an anthropomorphic phantom extended with water-equivalent plastic. The measured...... was built and placed beneath the accelerator head, extending caudally from the field edge, to function as an extra collimator jaw. This shield reduced the fetal dose by a factor of 3.5. The peripheral dose components were also measured for simple rectangular fields and also here the collimator scatter...... was the greatest contributor to the peripheral dose. Therefore, the shielding used for the IMRT treatment of our patient could also be used when shielding in conventional radiotherapy. It is important for a radiation therapy department to be prepared for treatment of a pregnant patient to shield the fetus...

  16. Effect of low dose irradiation on subsets of T-lymphocyte of peripheral blood, spleen and tumor tissue

    International Nuclear Information System (INIS)

    Zou Huawei; Su Liaoyuan; Tian Hailin

    1998-01-01

    Purpose: In order to understand the mechanism of the stimulation effects of low dose radiation (LDR), the author observed the immune changes of T-lymphocyte subsets. Meteria and methods: Whole body of BALB/C bring-tumor mice were exposed to the doses of 5, 10, 20 and 50 cGy γ-rays. The changes of T-lymphocyte subsets in peripheral blood, spleen and tumor-infiltrating lymphocyte (TIL) were studied with flow cytometry (FCM). Results: the ratio of L 3 T 4 + /Lyt 2 + remarkable increased in the peripheral blood and spleen (p 3 T 4 + /Lyt 2 + further decreased in the TIL group of mice exposed 10 cGy (p 2 + molecules, were concentrated in the tumor tissues and they carried out the killing function to the tumor cells

  17. Peripheral nerve and ureteralo tolerance to intraoperative radiation therapy; Clinical and dose-response analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, E.G.; Gunderson, L.L.; Martin, J.K.; Baers, R.W.; Nagorney, D.M.; Podratz, K.C. (Mayo Clinic, Rochester, MN (USA))

    1990-07-01

    Between April 1981 and July 1984, 51 received intraoperative radiation therapy (IORT) as a component of therapy for the management of primary of recurrent pelvic malignancies which were initially unresectable for cure. For these patients, curative surgical alternatives did not exist, or would have involved extensive procedures such as pelvic exenteration, distal sacrectomy, hemipelvectomy, or hemicorporectemy. The primary disease was colorectal in 38 patients. Treatment consisted of external beam radiation (range 3000 to 6890 cGy, median 5040 cGy), surgical debulking when feasible, and an intraoperative electron beam boost to the gross of microscopic residual desease (dose range 1000 to 2500 cGy, median 1750 cGy) utilizing 9-18 MeV electrons. The most common IORT associated toxicities were peripheral neurophaty and ureteral obstruction. None were life-threatening or fatal in severity. Of the 50 patients evaluable for neurotoxicity analysis, 16 (32%) developed peripheral neurophaty consisting of pain in 16 patients, numbness and tingling in 11, and weakness in 8. The pain, numbness and tingling resolved in about 40% of patients, while weakness resolved in only 1 of 8. Sixteen ureters were initially unobstructed by tumor at the time of IORT. Of these, 10 (63%) subsequently showed evidence of obstruction and hydronephrosis. The development of neurotoxicity was more common at IORT doses of 1500 cGy or more versus 1000 cGy. Ureteral obstruction with hydronephrosis occurred more frequently at IORT doses of 1250 cGy or more compared to 1000 cGy. There was no relationship between the likelihood of developing complications and the total external beam dose. The observed dependence of human nerve toxicity primarily on the IORT dose is consistent with data generated form animal experiments. (author). 21 refs.; 4 tabs.

  18. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  20. High-dose 8% capsaicin patch in treatment of chemotherapy-induced peripheral neuropathy: single-center experience.

    Science.gov (United States)

    Filipczak-Bryniarska, Iwona; Krzyzewski, Roger M; Kucharz, Jakub; Michalowska-Kaczmarczyk, Anna; Kleja, Justyna; Woron, Jarosław; Strzepek, Katarzyna; Kazior, Lucyna; Wordliczek, Jerzy; Grodzicki, Tomasz; Krzemieniecki, Krzysztof

    2017-08-17

    High-dose capsaicin patch is effective in treatment of neuropathic pain in HIV-associated neuropathy and diabetic neuropathy. There are no studies assessing effectiveness of high-dose capsaicin patch in treatment of chemotherapy-induced peripheral neuropathy. We sought to determine the effectiveness of treatment of pain associated with chemotherapy-induced peripheral neuropathy with high-dose capsaicin patch. Our study group consisted of 18 patients with clinically confirmed oxaliplatin-induced neuropathy. Baseline characteristic including underling disease, received cumulative dose of neurotoxic agent, neuropathic symptoms, prior treatment and initial pain level were recorded. Pain was evaluated with Numeric Rating Scale prior to treatment with high-dose capsaicin and after 1.8 day and after 8 and 12 weeks after introducing treatment. Patients were divided into two groups accordingly to the amount of neurotoxic agent that caused neuropathy (high sensitivity and low sensitivity group). Most frequent symptoms of chemotherapy-induced neuropathy were: pain (88.89%), paresthesis (100%), sock and gloves sensation (100%) and hypoesthesis (100%). Initial pain level was 7.45 ± 1.14. Mean cumulative dose of oxaliplatin after which patients developed symptoms was 648.07 mg/m 2 . Mean pain level after 12 weeks of treatment was 0.20 ± 0.41. When examined according to high and low sensitivity to neurotoxic agent patients with low sensitivity had higher pain reduction, especially after 8 days after introducing treatment (69.55 ± 12.09 vs. 49.40 ± 20.34%; p = 0.02) and after 12 weeks (96.96 ± 5.56 vs. 83.93 ± 18.59%; p = 0.04). High-dose capsaicin patch is an effective treatment for pain associated with chemotherapy-induced neuropathy in patients treated with oxaliplatin. Patients with lower sensitivity to neurotoxic agents have better response to treatment and pain reduction.

  1. Normal tissue tolerance to external beam radiation therapy: Peripheral nerves; Dose de tolerance a l'irradiation des tissus sains: les nerfs peripheriques

    Energy Technology Data Exchange (ETDEWEB)

    Henriques de Figueiredo, B.; Dejean, C.; Sargos, P.; Kantor, G. [Departement de radiotherapie, institut Bergonie, centre regional de lutte contre le cancer, 33 - Bordeaux (France); Huchet, A.; Mamou, N. [Service d' oncologie medicale et de radiotherapie, CHU Saint-Andre, 33 - Bordeaux (France); Loiseau, H. [Service de neurochirurgie, CHU Pellegrin, 33 - Bordeaux (France)

    2010-07-15

    Plexopathies and peripheral neuropathies appear progressively and with several years delay after radiotherapy. These lesions are observed principally after three clinical situations: supraclavicular and axillar irradiations for breast cancer, pelvic irradiations for various pathologies and limb irradiations for soft tissue sarcomas. Peripheral nerves and plexus (brachial and lumbosacral) are described as serial structures and are supposed to receive less than a given maximum dose linked to the occurrence of late injury. Literature data, mostly ancient, define the maximum tolerable dose to a threshold of 60 Gy and highlight also a great influence of fractionation and high fraction doses. For peripheral nerves, most frequent late effects are pain with significant differences of occurrence between 50 and 60 Gy. At last, associated pathologies (diabetes, vascular pathology, neuropathy) and associated treatments have probably to be taken into account as additional factors, which may increase the risk of these late radiation complications. (authors)

  2. [Changes and significance of peripheral blood platelet count in tumor shrinkage induced by a low dose of CTX in T739 mice].

    Science.gov (United States)

    Li, Mo-lin; Jia, Yu-jie; Jiang, Miao-na; Shu, Xiao-hong; Li, Chuan-gang

    2008-06-01

    To establish a mouse model for BTT739 tumor-bearing mice cured by a low dose of cyclophosphamide (CTX). And then to observe the dynamic changes and significance of peripheral blood counts especially blood platelet count during tumor shrinkage induced by a low dose of CTX in T739 mice. Mouse bladder carcinoma tissues were inoculated subcutaneously into T739 mice. Seven days later, different doses of CTX or the same volume of NS were administered intraperitoneally to treat these tumor-bearing T739 mice. Tumor sizes were observed and recorded subsequently to find out the minimal dose of CTX that could cure most of these tumor-bearing mice. Then another 12 tumor-bearing mice were randomly divided into 15 mg/kg CTX treatment group and control group. Blood samples were obtained from orbital venous sinus on different times after CTX treatment. Complete blood counts were performed and the relationship between peripheral blood platelet counts and tumor shrinkage was analyzed. Within 2 weeks after CTX treatment, the speed of tumor shrinkage had a positive relationship with the dose of CTX used; but the survival rate of the tumor-bearing mice had a negative relationship with the dose of CTX used in 2 months after CTX treatment. 15 mg/kg CTX could cure most of the tumor bearing mice, while it had no remarkably inhibitive effects on peripheral blood cells. The perpherial platelet count increased to (1483.4+/-184.4)x10(9)/L in mice 6 h after CTX treatment. There was significant difference compared with that in mice of control group (1086.6+/-81.0)x10(9)/L (P0.05). CTX 15 mg/kg could cure most of bladder tumor-bearing T739 mice. The transient increase of the peripheral platelet count in 6 h after CTX treatment may relate to the antitumor effects of CTX.

  3. Peripheral arterial disease in a female using high-dose combined oral contraceptive pills.

    Science.gov (United States)

    Pallavee, P; Samal, Sunita; Samal, Rupal

    2013-01-01

    The association between oral contraceptive (OC) pills and vascular diseases is well-known, although, the present generation of pills is considered to be relatively safer in this regard. Hormonal treatment for severe abnormal uterine bleeding is usually considered after ruling out malignancy, when such bleeding is resistant to all other forms of treatment. We report a case of severe peripheral arterial disease in a female, who had been on high-dose OC pills for an extended period of time for severe uterine bleeding.

  4. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  5. The effect of instrument alignment on peripheral refraction measurements by automated optometer.

    Science.gov (United States)

    Ehsaei, Asieh; Chisholm, Catharine M; Mallen, Edward A H; Pacey, Ian E

    2011-07-01

    Interest in peripheral refraction measurement has grown in recent years in response to the insight it may provide into myopia development. In light of the likely increase in the clinical use of open-field autorefractors for peripheral refraction measurements, the question of instrument alignment and its impact on the accuracy of refraction measurements is raised. The aim of this study was to investigate the accuracy and precision when an open-field device was moved away from alignment with the corneal reflex towards the pupil margins, and to determine the optimum alignment position for peripheral refraction measurements. Autorefractions were performed on the right eyes of 10 healthy participants using the Shin-Nippon NVision-K 5001 autorefractor. At least five measurements were taken with the subject fixating a distance target in the primary position of gaze, and then four peripheral fixation targets located along the horizontal meridian (10° and 20° eccentricities in the nasal and temporal retina). Measurements were taken at seven alignment positions across the pupil for each fixation angle. Refraction was recorded as the spherical and cylindrical power. The central objective refraction achieved under cycloplegia based on the autorefraction result for the whole sample, ranged between -5.62 D and +1.85 D for the value of sphere, with a maximum astigmatism of -1.00 D. Acceptable alignment position range varied with fixation angle but was -1.0 to +1.0 mm in width across the pupil. Peripheral refraction measurements centred on the entrance pupil were as reliable as those centred on the corneal reflex. Our data suggest that for peripheral refraction measurements, there is a range of acceptable positions and operators can be confident of the validity of results obtained if aligned half way between the pupil centre and corneal reflex. The alignment becomes more critical at greater eccentricities. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.

  6. Peripheral DXA measurement around ankle joint to diagnose osteoporosis as assessed by central DXA measurement.

    Science.gov (United States)

    Sung, Ki Hyuk; Choi, Young; Cho, Gyeong Hee; Chung, Chin Youb; Park, Moon Seok; Lee, Kyoung Min

    2018-02-05

    This study evaluated the correlation between central and peripheral bone mineral density (BMD) of the ankle joint, using dual-energy X-ray absorptiometry (DXA). We also investigated whether peripheral ankle BMD could be used to identify individuals who were diagnosed with osteoporosis, using central DXA. We recruited 134 volunteers aged 20-90 years who agreed to participate in this study. Central BMD of the lumbar spine and left femur, and peripheral BMD of the medial malleolus, distal tibia, lateral malleolus, and talus were measured with DXA. Among the peripheral sites of the ankle, the highest and lowest BMD were observed in the talus and lateral malleolus, respectively. All peripheral DXA measurements of the ankle joint were significantly correlated with central DXA measurements. There was a good correlation (r: 0.656-0.725) between peripheral and central BMD for the older age group (> 50 years), but fair-to-good correlation (r: 0.263-0.654) for the younger age group (ankle joint between osteoporosis and non-osteoporosis were 0.548 g/cm 2 (sensitivity, 89.0%; specificity, 69.0%) for the medial malleolus, 0.626 g/cm 2 (sensitivity, 83.3%; specificity, 82.8%) for the distal tibia, 0.47 g/cm 2 (sensitivity, 100.0%; specificity, 65.5%) for the lateral malleolus, and 0.973 g/cm 2 (sensitivity, 72.2%; specificity, 83.6%) for the talus (p ankle joint and central BMD for older age group. Further study is required to use the ankle DXA as a valid clinical tool for the diagnosis of osteoporosis and fracture risk assessment.

  7. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  8. Technical Note: Comparison of peripheral patient dose from MR-guided 60 Co therapy and 6 MV linear accelerator IGRT.

    Science.gov (United States)

    Hauri, Pascal; Hälg, Roger A; Schneider, Uwe

    2017-07-01

    The use of X-ray imaging in radiation therapy can give a substantial dose to the patient. A Cobalt machine combined with an magnetic resonance imaging (MRI) was recently introduced to clinical work. One positive aspect of using non-ionizing imaging devices is the reduction of the patient exposure. The purpose of this study was to quantify the difference in out-of-field dose to the patient between the image guided radiation therapy (IGRT) treatment applied with a linear accelerator with cone beam CT (CBCT) equipment and a Cobalt machine combined with an MRI. The treatment of a rhabdomyosarcoma in the prostate was planned and irradiated using different modalities and radiation therapy machines. The whole-body dose was measured for a 3D-conformal radiation therapy (3DCRT), an intensity-modulated radiation therapy (IMRT), and a volumetric-modulated arc therapy plan applied with a conventional linear accelerator operated at 6 MV beam energy. Additionally, the dose of an IMRT plan applied with a 60 Co machine combined with an MRI was measured. Furthermore, the dose of one CBCT scan using the linear accelerator's on-board imaging system was determined. The 3D dose measurements were performed in an anthropomorphic phantom containing 168 slots for thermoluminescence dosimeters (TLDs). A combination of LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P (TLD100H) was used to accurately determine the in- and out-of-field dose. The plans were rescaled to different fractionation schemes (2 Gy, 3 Gy, and 5 Gy fraction dose) and the dose of one CBCT scan was additionally added to the treatment dose per fraction applied with the linear accelerator. The resulting absorbed doses per fraction of the two machines were compared. In the target region, all measured treatment plans presented the same magnitude of dose, while the CBCT dose was a factor of 100 smaller. Close to the planned target volume (PTV), the dose from the 60 Co machine was a factor of two higher compared with the 3DCRT + CBCT dose. Up

  9. Induction and persistence of multicentric chromosomes in cultured human peripheral blood lymphocytes following high-dose gamma irradiation

    International Nuclear Information System (INIS)

    Suto, Yumiko; Hirai, Momoki; Akiyama, Miho; Nakagawa, Takashi; Tominaga, Takako; Suzuki, Toshikazu; Sugiura, Nobuyuki; Yuki, Masanori; Nakayama, Fumiaki

    2012-01-01

    Among radiation-induced chromosome aberrations, multicentric chromosomes, as represented by dicentric chromosomes (dicentrics), are regarded as sensitive and specific biomarkers for assessing radiation dose in the 0 to 5 Gy range. The objective of this study was to characterize chromosome aberrations induced in vitro by a higher dose of radiation. Peripheral blood lymphocytes were exposed to 15 Gy gamma rays at a dose rate of 0.5 Gy/min and harvested at 48, 50, 52, 54, 56 and 72 h. The first mitotic peak appeared at 52-54 h, showing about a 6 h mitotic delay as compared with nonirradiated control cultures. Cell-cycle analysis of parallel and simultaneous cultures by sister-chromatid differentiation staining suggests that metaphase cells examined in 48-56 h cultures were in the first mitosis after culture initiation. The mean dicentric equivalent counts ranged from 9.0 to 9.3 in consecutively harvested cultures with no significant differences among them. At 72 h, about 20% of dividing cells were tetraploid, persisting with faithfully replicated unstable chromosome aberrations. The non-random distribution of replicated chromosome pairs, deduced from multicolor fluorescence in situ hybridization analysis, led us to surmise that the predominant mechanism underlying the induction of tetraploid cells is endoreduplication. These findings suggest that a high-dose in vitro irradiation applied to peripheral blood lymphocytes may affect on the replication process, in addition to structural chromosome damage. (author)

  10. Paclitaxel Plasma Concentration after the First Infusion Predicts Treatment-Limiting Peripheral Neuropathy.

    Science.gov (United States)

    Hertz, Daniel L; Kidwell, Kelley M; Vangipuram, Kiran; Li, Feng; Pai, Manjunath P; Burness, Monika; Griggs, Jennifer J; Schott, Anne F; Van Poznak, Catherine; Hayes, Daniel F; Lavoie Smith, Ellen M; Henry, N Lynn

    2018-04-27

    Purpose: Paclitaxel exposure, specifically the maximum concentration ( C max ) and amount of time the concentration remains above 0.05 μmol/L ( T c >0.05 ), has been associated with the occurrence of paclitaxel-induced peripheral neuropathy. The objective of this study was to validate the relationship between paclitaxel exposure and peripheral neuropathy. Experimental Design: Patients with breast cancer receiving paclitaxel 80 mg/m 2 × 12 weekly doses were enrolled in an observational clinical study (NCT02338115). Paclitaxel plasma concentration was measured at the end of and 16-26 hours after the first infusion to estimate C max and T c >0.05 Patient-reported peripheral neuropathy was collected via CIPN20 at each dose, and an 8-item sensory subscale (CIPN8) was used in the primary analysis to test for an association with T c >0.05 Secondary analyses were conducted using C max as an alternative exposure parameter and testing each parameter with a secondary endpoint of the occurrence of peripheral neuropathy-induced treatment disruption. Results: In 60 subjects included in the analysis, the increase in CIPN8 during treatment was associated with baseline CIPN8, cumulative dose, and relative dose intensity ( P 0.05 ( P = 0.27) nor C max ( P = 0.99). In analyses of the secondary endpoint, cumulative dose (OR = 1.46; 95% confidence interval (CI), 1.18-1.80; P = 0.0008) and T c >0.05 (OR = 1.79; 95% CI, 1.06-3.01; P = 0.029) or C max (OR = 2.74; 95% CI, 1.45-5.20; P = 0.002) were associated with peripheral neuropathy-induced treatment disruption. Conclusions: Paclitaxel exposure is predictive of the occurrence of treatment-limiting peripheral neuropathy in patients receiving weekly paclitaxel for breast cancer. Studies are warranted to determine whether exposure-guided dosing enhances treatment effectiveness and/or prevents peripheral neuropathy in these patients. Clin Cancer Res; 1-9. ©2018 AACR. ©2018 American Association for Cancer Research.

  11. Hyperacute peripheral neuropathy is a predictor of oxaliplatin-induced persistent peripheral neuropathy.

    Science.gov (United States)

    Tanishima, Hiroyuki; Tominaga, Toshiji; Kimura, Masamichi; Maeda, Tsunehiro; Shirai, Yasutsugu; Horiuchi, Tetsuya

    2017-05-01

    Chronic peripheral neuropathy is a major adverse response to oxaliplatin-containing chemotherapy regimens, but there are no established risk factors pertaining to it. We investigated the efficacy of hyperacute peripheral neuropathy (HAPN) as a predictor of oxaliplatin-induced persistent peripheral neuropathy (PPN). Forty-seven cases of stage III colorectal cancer who received adjuvant chemotherapy with oxaliplatin after curative surgery between January 2010 and August 2014 were retrospectively reviewed. HAPN was defined as acute peripheral neuropathy (APN) occurring on day 1 (≤24 h after oxaliplatin infusion) of the first cycle. PPN was defined as neuropathy lasting >1 year after oxaliplatin discontinuation. The average total dose of oxaliplatin was 625.8 mg/m 2 , and the average relative dose intensity was 66.7%. Twenty-two of the 47 patients (46.8%) had PPN and 13 (27.7%) had HAPN. Male sex, treatment for neuropathy, HAPN, and APN were significantly more frequent in patients with PPN (p = 0.013, 0.02, <0.001, and 0.023, respectively). There was no significant difference in the total oxaliplatin dose between patients with and without PPN (p = 0.061). Multivariate analyses revealed total dose of oxaliplatin and HAPN as independent predictors of PPN [p = 0.015; odds ratio (OR) = 1.005, 95% confidence interval (CI), 1.001-1.009 and p = 0.001; OR = 75.307, 5.3-1070.123, respectively]. The total dose of oxaliplatin was relatively lower in patients with HAPN than that in those without HAPN in the PPN-positive group (not significant, p = 0.068). HAPN was found to be a predictor of oxaliplatin-induced PPN.

  12. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy

    Science.gov (United States)

    Kramer, Rita; Bielawski, Jacek; Kistner-Griffin, Emily; Othman, Alaa; Alecu, Irina; Ernst, Daniela; Kornhauser, Drew; Hornemann, Thorsten; Spassieva, Stefka

    2015-01-01

    Peripheral neuropathy is a major dose-limiting side effect of paclitaxel and cisplatin chemotherapy. In the current study, we tested the involvement of a novel class of neurotoxic sphingolipids, the 1-deoxysphingolipids. 1-Deoxysphingolipids are produced when the enzyme serine palmitoyltransferase uses l-alanine instead of l-serine as its amino acid substrate. We tested whether treatment of cells with paclitaxel (250 nM, 1 µM) and cisplatin (250 nM, 1 µM) would result in elevated cellular levels of 1-deoxysphingolipids. Our results revealed that paclitaxel, but not cisplatin treatment, caused a dose-dependent elevation of 1-deoxysphingolipids levels and an increase in the message and activity of serine palmitoyltransferase (P peripheral neuropathy symptoms [evaluated by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-chemotherapy-induced peripheral neuropathy-20 (CIPN20) instrument] and the 1-deoxysphingolipid plasma levels (measured by mass spectrometry) in 27 patients with breast cancer who were treated with paclitaxel chemotherapy. Our results showed that there was an association between the incidence and severity of neuropathy and the levels of very-long-chain 1-deoxyceramides such as C24 (P neuropathy (P peripheral neuropathy.—Kramer, R., Bielawski, J., Kistner-Griffin, E., Othman, A., Alecu, I., Ernst, D., Kornhauser, D., Hornemann, T., Spassieva, S. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy. PMID:26198449

  13. Antiproton Radiotherapy Peripheral Dose from Secondary Neutrons produced in the Annihilation of Antiprotons in the Target

    CERN Document Server

    Fahimian, Benjamin P; Keyes, Roy; Bassler, Niels; Iwamoto, Keisuke S; Zankl, Maria; Holzscheiter, Michael H

    2009-01-01

    The AD-4/ACE collaboration studies the biological effects of antiprotons with respect to a possible use of antiprotons in cancer therapy. In vitro experiments performed by the collaboration have shown an enhanced biological effectiveness for antiprotons relative to protons. One concern is the normal tissue dose resulting from secondary neutrons produced in the annihilation of antiprotons on the nucleons of the target atoms. Here we present the first organ specific Monte Carlo calculations of normal tissue equivalent neutron dose in antiproton therapy through the use of a segmented CT-based human phantom. The MCNPX Monte Carlo code was employed to quantify the peripheral dose for a cylindrical spread out Bragg peak representing a treatment volume of 1 cm diameter and 1 cm length in the frontal lobe of a segmented whole-body phantom of a 38 year old male. The secondary neutron organ dose was tallied as a function of energy and organ.

  14. The peripheral artery questionnaire: a new disease-specific health status measure for patients with peripheral arterial disease.

    Science.gov (United States)

    Spertus, John; Jones, Philip; Poler, Sherri; Rocha-Singh, Krishna

    2004-02-01

    The most common indication for treating patients with peripheral arterial disease is to improve their health status: their symptoms, function, and quality of life. Quantifying health status requires a valid, reproducible, and sensitive disease-specific measure. The Peripheral Artery Questionnaire (PAQ) is a 20-item questionnaire developed to meet this need by quantifying patients' physical limitations, symptoms, social function, treatment satisfaction, and quality of life. Psychometric and clinical properties of the PAQ were evaluated in a prospective cohort study of 44 patients undergoing elective percutaneous peripheral revascularization. To establish reproducibility, 2 assessments were performed 2 weeks apart and before revascularization. The change in scores before and 6 weeks after revascularization were used to determine the instruments' responsiveness and were compared with the Short Form-36 and the Walking Impairment Questionnaire. A series of cross-sectional analyses were performed to establish the construct validity of the PAQ. The 7 domains of the PAQ were internally reliable, with Cronbach alpha = 0.80 to 0.94. The test-retest reliability analyses revealed insignificant mean changes of 0.6 to 2.3 points (P = not significant for all). Conversely, the change after revascularization ranged from 13.7 to 41.9 points (P PAQ to clinical improvement. The PAQ Summary Scale was the most sensitive of all scales tested. Construct validity was established by demonstrating correlations with other measures of patient health status. The PAQ is a valid, reliable, and responsive disease-specific measure for patients with peripheral arterial disease. It may prove to be a useful end point in clinical trials and a potential aid in disease management.

  15. Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

    Science.gov (United States)

    Purwaningsih, S.; Lubis, L. E.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    This research was aimed to check the patterns of dose profile on adult and pediatric head scan. We compared measurement result on dose profile along the z- axis rotation at peripheries and center phantom with a variety of pitch, i.e. 0.75, 1, 1.5 for adult and pediatric head protocol, keeping the rest of the scan parameters constant. Measurements were performed on homogeneous, cylindrical PMMA phantom with diameters of 16 and 10 cm using XR-QA2 Gafchromic film and TLD as dosimeters. The measurement result indicated a decrease in the dose about 50% and 47% for adult and pediatric head scan with the increase of pitch. For 0.75 value of pitch adult head scan, dose range for each position were (2.4 - 5.0) cGy, (3.1 - 5.3) cGy, (2.2 - 4.5) cGy, (2.8 - 5.3) cGy, and (3.3 - 5.6) cGy for position of center, 3, 6, 9 and 12 o'clock peripheral phantom position respectively. Dose profile for adult and pediatric head scan protocols has pattern curve with the maximum dose in the middle and tendency of symmetry near the edges, with different the plateau length along z- axis direction in accordance to the measurement position in the phantom.

  16. Influence of radiation-dose pattern from inhaled beta--gamma-emitting radionuclides on canine peripheral lymphocytes

    International Nuclear Information System (INIS)

    Jones, R.K.; Boecker, B.B.; Pickrell, J.A.; Hobbs, C.H.; McClellan, R.O.

    1976-01-01

    As part of studies assess the biological hazards associated with inhaled radionuclides, periodic hematologic evaluations were performed on beagle dogs given a single nose-only exposure to aerosols of beta--gamma-emitting isotopes. The physical form and specific radionuclides selected produced radiation-dose patterns representative of those which might be encountered in the event of human accidental exposures. Dogs received graded lung burdens of either 90 Y, 91 Y, 144 Ce, or 90 Sr, each in fused clay. Differences in the effective half-lives of these radionuclides resulted in a spectrum of cumulative radiation doses to lung delivered at a variety of dose rates. Since the form in which the radionuclides were inhaled was relatively insoluble, the lung and intrathoracic tissues represented the primary recipient of the dose. Regardless of the effective half-life of radionuclide retention, a dose-related depression of peripheral lymphocytes was observed at various times after inhalation exposure. The time at which maximum depression and subsequent recovery occurred, however, was most directly related to the effective half-life of the radionuclide. Of special interest was the persistence of lymphopenia through 2 1 / 2 years after exposure to 144 Ce and 90 Sr in fused clay where, other than tracheobronchial lymph nodes, the lymphoid tissue received very little radiation dose. The possible mechanisms responsible for lymphocyte depression from these various radiation-dose patterns are discussed

  17. The Induction of Chromosome Aberrations and Micronuclei in Human Peripheral Blood Lymphocytes at Low Doses of Radiation

    CERN Document Server

    Shmakova, N L; Krasavin, E A; Melnikova, L A; Fadeeva, T A

    2003-01-01

    The chromosome damage induced by the low doses of gamma-irradiation with ^{60}Co and X-rays in peripheral blood lymphocytes has been studied using different cytogenetic assays. Isolated lymphocytes were exposed to 0.01-1.0 Gy, simulated by PHA, and analysed for chromosome aberrations by the metaphase and the anaphase methods, by the micronucleus assay. Despite the quantitative differences in the amount of chromosome damage revealed by different methods, all of them demonstrated complex nonlinear dose dependence of the frequency of aberrant cells and aberrations. At the dose range of 0.01-0.05 Gy the cells showed the highest radiosensitivity; at 0.05-0.5 Gy the dose-independent induction of chromosome damage was revealed. At the doses of 0.5-1.0 Gy the dose-effect curves became linear with the decreased slope compared with the initial one (by a factor of 5 to 10 for different criteria) reflecting a higher radioresistance of the cells. These data confirm the idea that the direct linear extrapolation of high-dos...

  18. Dose assessment by quantification of chromosome aberrations and micronuclei in peripheral blood lymphocytes from patients exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Barbosa, Isvania; Pereira-MagnataI, Simey; Amaral, Ademir [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia - GERAR; Sotero, Graca [Fundacao de Hematologia e Hemoterapia, Recife, PE (Brazil); Melo, Homero Cavalcanti [Hospital do Cancer, Recife, PE (Brazil). Centro de Radioterapia de Pernambuco]. E-mail: isvania@uol.com.br

    2005-07-15

    Scoring of unstable chromosome aberrations (dicentrics, rings and fragments) and micronuclei in circulating lymphocytes are the most extensively studied biological means for estimating individual exposure to ionizing radiation (IR), which can be used as complementary methods to physical dosimetry or when the latter cannot be performed. In this work, the quantification of the frequencies of chromosome aberrations and micronuclei were carried out based on cytogenetic analyses of peripheral blood samples from 5 patients with cervical uterine cancer following radiotherapy in order to evaluate the absorbed dose as a result of partial-body exposure to 60Co source. Blood samples were collected from each patient in three phases of the treatment: before irradiation, 24 h after receiving 0.08 Gy and 1.8 Gy, respectively. The results presented in this report emphasize biological dosimetry, employing the quantification of chromosome aberrations and micronuclei in lymphocytes from peripheral blood, as an important methodology of dose assessment for either whole or partial-body exposure to IR.

  19. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  20. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  1. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  2. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  3. Development and experimental validation of a tool to determine out-of-field dose in radiotherapy

    International Nuclear Information System (INIS)

    Bessieres, I.

    2013-01-01

    Over the last two decades, many technical developments have been achieved on intensity modulated radiotherapy (IMRT) and allow a better conformation of the dose to the tumor and consequently increase the success of cancer treatments. These techniques often reduce the dose to organs at risk close to the target volume; nevertheless they increase peripheral dose levels. In this situation, the rising of the survival rate also increases the probability of secondary effects expression caused by peripheral dose deposition (second cancers for instance). Nowadays, the peripheral dose is not taken into account during the treatment planning and no reliable prediction tool exists. However it becomes crucial to consider the peripheral dose during the planning, especially for pediatric cases. Many steps of the development of an accurate and fast Monte Carlo out-of-field dose prediction tool based on the PENELOPE code have been achieved during this PhD work. To this end, we demonstrated the ability of the PENELOPE code to estimate the peripheral dose by comparing its results with reference measurements performed on two experimental configurations (metrological and pre-clinical). During this experimental work, we defined a protocol for low doses measurement with OSL dosimeters. In parallel, we highlighted the slow convergence of the code for clinical use. Consequently, we accelerated the code by implementing a new variance reduction technique called pseudo-deterministic transport which is specifically with the objective of improving calculations in areas far away from the beam. This step improved the efficiency of the peripheral doses estimation in both validation configurations (by a factor of 20) in order to reach reasonable computing times for clinical application. Optimization works must be realized in order improve the convergence of our tool and consider a final clinical use. (author) [fr

  4. Hydrogen gas production is associated with reduced interleukin-1β mRNA in peripheral blood after a single dose of acarbose in Japanese type 2 diabetic patients.

    Science.gov (United States)

    Tamasawa, Atsuko; Mochizuki, Kazuki; Hariya, Natsuyo; Saito, Miyoko; Ishida, Hidenori; Doguchi, Satako; Yanagiya, Syoko; Osonoi, Takeshi

    2015-09-05

    Acarbose, an α-glucosidase inhibitor, leads to the production of hydrogen gas, which reduces oxidative stress. In this study, we examined the effects of a single dose of acarbose immediately before a test meal on postprandial hydrogen gas in breath and peripheral blood interleukin (IL)-1β mRNA expression in Japanese type 2 diabetic patients. Sixteen Japanese patients (14 men, 2 women) participated in this study. The mean±standard deviation age, hemoglobin A1c and body mass index were 52.1±15.4 years, 10.2±2.0%, and 27.7±8.0kg/m(2), respectively. The patients were admitted into our hospital for 2 days and underwent test meals at breakfast without (day 1) or with acarbose (day 2). We performed continuous glucose monitoring and measured hydrogen gas levels in breath, and peripheral blood IL-1β mRNA levels before (0min) and after the test meal (hydrogen gas: 60, 120, 180, and 300min; IL-1β: 180min). The induction of hydrogen gas production and the reduction in peripheral blood IL-1β mRNA after the test meal were not significant between days 1 (without acarbose) and 2 (with acarbose). However, the changes in total hydrogen gas production from day 1 to day 2 were closely and inversely associated with the changes in peripheral blood IL-1β mRNA levels. Our results suggest that an increase in hydrogen gas production is inversely associated with a reduction of the peripheral blood IL-1β mRNA level after a single dose of acarbose in Japanese type 2 diabetic patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  6. Functional deficits in peripheral nerve mitochondria in rats with paclitaxel- and oxaliplatin-evoked painful peripheral neuropathy

    OpenAIRE

    Zheng, Huaien; Xiao, Wen Hua; Bennett, Gary J.

    2011-01-01

    Cancer chemotherapeutics like paclitaxel and oxaliplatin produce a dose-limiting chronic sensory peripheral neuropathy that is often accompanied by neuropathic pain. The cause of the neuropathy and pain is unknown. In animal models, paclitaxel-evoked and oxaliplatin-evoked painful peripheral neuropathies are accompanied by an increase in the incidence of swollen and vacuolated mitochondria in peripheral nerve axons. It has been proposed that mitochondrial swelling and vacuolation are indicati...

  7. Isotopic diagnosis of peripheral thrombosis

    International Nuclear Information System (INIS)

    Cornu, Pierre; Scalet, Michel

    1975-01-01

    Radio-isotope diagnosis of peripheral venous thrombosis, using tracer doses of iodine-labelled fibrinogen, provides an important contribution to the solution of the worrying problem of pulmonary embolism due to latent phlebitis. This elegant and precise technique permits early diagnosis of venous thrombosis of the lower limbs at a subclinical stage. It has permitted determination of the frequency, both after surgery and after myocardial infarction, and above all, it provides an objective criterion for assessment of the efficacy of prophylactic measures proposed [fr

  8. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  9. Estimation of the dose delivered to critical organs outside the radiation beams of a Mevatron MX6700 and a Mevatron KDS

    International Nuclear Information System (INIS)

    Chakkor, H.; Ginjaume, M.; Sanchez-Reyes, A.; Ortega, X.

    1994-01-01

    The radiation dose received outside collimated radiation is named peripheral dose. The peripheral radiation dose is especially important from a clinical point of view, when some critical organs as eye-lens or gonads are near the target volume,thus generating potential cataract formation, or gonadal disfunction. Accurate prediction of the peripheral dose distribution can also be used in retrospective studies to evaluate possible correlation between radiotherapy dose and secondary cancer incidence in tissues external to the treatment field. The main objective of the present work was the measurement of peripheral dose produced in Siemens Mevatron MX6700 (6 MV) and a Siemens Mevatron KDS (6 and 18 MV linear accelerators. Measurement techniques include the use of a ionization chamber and thermoluminescent dosimeters (TLD) in simple polystyrene phantoms and anthropomorphic phantoms. To obtain high accuracy in the measurements 3 dosemeters were placed in every analyzed point and 10 TLD were situated at the reference point. In addition, an individual calibration factor was used in the dose determination. Doses received in eye-lens, hypophysis, thyroid breast, uterus and gonads, during typical neoplasia treatments as breast neoplasia, head and neck tumour, lung or pelvis tumour and lymphomas are reported. 1 tab.; 1 ref. (author)

  10. Dose profile in computed tomography chest scan; Perfil de dose em varredura de torax em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno B., E-mail: bbo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais; Mourao, Arnaldo P. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET/MG), Belo Horizonte, MG (Brazil); Alonso, Thessa C.; Silva, Teogenes A. da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2010-07-01

    For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRL's) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to the DRL's can be verified by measuring the dose distribution in CT scans and MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests to the study that are presented in the ANVISA (National Agency of Sanitary Vigilance) Guide. The purpose of this study is to investigate, in a chest scan, the variation of dose in CT. To measure the dose profile are used lithium fluoride thermoluminescent dosimeters (TLD-100 Rod) distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate (PMMA). The data obtained allow us to observe the variation of the dose profile inside the phantom. The peripheral region shows higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom (41,58{+-}5,10) mGy at the midpoint of the longitudinal axis. The results will contribute to disseminate the proper procedure and optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRL's. (author)

  11. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  12. Brachytherapy dose measurements in heterogeneous tissues

    International Nuclear Information System (INIS)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H.; Rubo, R.

    2014-08-01

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  13. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  14. Sensitivity of human peripheral lymphocyte chromosomes to various X-ray doses and subsequent storage in Plexiglass or glass containers

    International Nuclear Information System (INIS)

    Ivanov, B.; Bulanova, M.; Geogieva, I.

    1979-01-01

    A study was performed to determine whether chromosomal aberrations produced in vitro by various X-ray doses in human lymphocytes were affected by post-irradiation storage of the blood in plastic or glass containers. Following X-ray doses of up to 400 R, the yields of cells with aberrations and the incidence of dicentrics, rings, interstitial deletions, symmetrical changes and chromosome fragments increased with dose. After storage of the irradiated lymphocytes in either Plexiglass or glass, the values for exchange aberrations, deletions and aberrant cells were compared. The only statistically significant difference was a slight increase in the percentage of aberrant cells stored in the plastic containers at the 400 R dose level. It was concluded that plastics appear to have a sensitizing effect on the genetic structure of the peripheral lymphocyte and thus the use of this material to store blood in biological dosimetry studies should be discouraged. (U.K.)

  15. Traceability and standardization of large dose measurement

    International Nuclear Information System (INIS)

    Tanaka, Ryuichi

    1989-01-01

    The reliability of dose control for radiation sterilization and food irradiation depends on the relative errors in measurements made by different dosimeters and the level of process control techniques as well as traceability. International efforts have been made for standardization of dose measurement procedures and process control techniques. A system for traceability of large dose measurement has already been established in the U.S. and Britain, and it has become urgent in Japan to establish a traceability system. For process control for radiation sterilization of medical tools, dose measurement is replacing the use of a biological indicator to play a more important role in relation to sterilization assurance. AAMI is making efforts to establish implementation standards for process control for industrial sterilization with electron beam. In Japan, the Radiation Irradiation Promotion Association has developed a manual 'Measurement of Dose of Electron Beam for Irradiation' to be used by users of electron beam for irradiation. Further efforts are required to establish a proper traceability system and standardization of dose measurement. (N.K.)

  16. New sonographic measures of peripheral nerves: a tool for the diagnosis of peripheral nerve involvement in leprosy

    Directory of Open Access Journals (Sweden)

    Marco Andrey Cipriani Frade

    2013-05-01

    Full Text Available To evaluate ultrasonographic (US cross-sectional areas (CSAs of peripheral nerves, indexes of the differences between CSAs at the same point (∆CSAs and between tunnel (T and pre-tunnel (PT ulnar CSAs (∆TPTs in leprosy patients (LPs and healthy volunteers (HVs. Seventy-seven LPs and 49 HVs underwent bilateral US at PT and T ulnar points, as well as along the median (M and common fibular (CF nerves, to calculate the CSAs, ∆CSAs and ∆TPTs. The CSA values in HVs were lower than those in LPs (p 80% and ∆TPT had the highest specificity (> 90%. New sonographic peripheral nerve measurements (∆CSAs and ∆TPT provide an important methodological improvement in the detection of leprosy neuropathy.

  17. Time and dose dependent expression in the proteome of human peripheral blood mononuclear cells with γ-irradiation

    International Nuclear Information System (INIS)

    Nishad, S.; Ghosh, Anu

    2014-01-01

    The aim of present study is to investigate time and dose dependent differential protein expression pattern of human peripheral blood mononuclear cells (PBMCs) after acute gamma irradiation. For this purpose, PBMCs extracted from eight healthy individuals were irradiated using 60 Co gamma rays (0.3 Gy and 1 Gy) and compared with sham irradiated controls. Total proteins were extracted 1 and 4 hour post irradiation and analyzed using 2-D gel electrophoresis. A fold change of 1.5 in spot intensity was considered as 'biological significant'. Protein identification was performed by MALDI-TOF mass spectrometry. The MS/MS spectra were interrogated using Mascot 2.1 for searching against SWISS-PROT database. One-hour post irradiation, 18 proteins showed a significant difference between the sham (0 Gy) and 0.3 Gy irradiated group (6 proteins up-regulated and 12 proteins down-regulated) and 17 proteins between the sham (0 Gy) and 1 Gy irradiated group (9 proteins up-regulated and 8 down-regulated). Four hours after irradiation, 16 proteins were differentially expressed between the sham irradiated and 0.3 Gy treated group (5 proteins up-regulated and 11 proteins downregulated). Relatively high dose of 1 Gy showed modulation of 13 proteins (5 proteins upregulated and 8 proteins down regulated) after 4 hours. There were 15 proteins that were observed both at the early time point of 1-hour and the late time point of 4-hour. Important among these were, proteins involved in cytoskeletal organization like Actin, Plastin-2, Vinculin, PDZ and LIM domain protein, WD repeat containing protein and the chaperone proteins like HSP 90-alpha and Protein disulfide-isomerase A3. Proteins like thiol specific antioxidant peroxiredoxin-6 (indicating increased levels of ROS and oxidative stress) showed dose specific expression while proteins like Ras-related Rap-1b-like protein (involved in cell survival) were observed with both 0.3 Gy and 1 Gy. During the study, human peripheral blood

  18. Patient and personnel dose measurements at selective coronarangiography

    International Nuclear Information System (INIS)

    Maripuu, E.

    1977-01-01

    During 1975 dose measurements were performed on patients and doctors at the thoraxradiologic department of the Caroline Hospital in Stockholm, Sweden. The doses were measured during angiography. Skin doses are listed in tables. Also the doses to the bone marrow was estimated. LiF-dosemeters were used for the measurements. Calibration of the dosemeters and errors in the measurements are discussed

  19. An improved analytical model for CT dose simulation with a new look at the theory of CT dose

    International Nuclear Information System (INIS)

    Dixon, Robert L.; Munley, Michael T.; Bayram, Ersin

    2005-01-01

    Gagne [Med. Phys. 16, 29-37 (1989)] has previously described a model for predicting the sensitivity and dose profiles in the slice-width (z) direction for CT scanners. The model, developed prior to the advent of multidetector CT scanners, is still widely used; however, it does not account for the effect of anode tilt on the penumbra or include the heel effect, both of which are increasingly important for the wider beams (up to 40 mm) of contemporary, multidetector scanners. Additionally, it applied only on (or near) the axis of rotation, and did not incorporate the photon energy spectrum. The improved model described herein transcends all of the aforementioned limitations of the Gagne model, including extension to the peripheral phantom axes. Comparison of simulated and measured dose data provides experimental validation of the model, including verification of the superior match to the penumbra provided by the tilted-anode model, as well as the observable effects on the cumulative dose distribution. The initial motivation for the model was to simulate the quasiperiodic dose distribution on the peripheral, phantom axes resulting from a helical scan series in order to facilitate the implementation of an improved method of CT dose measurement utilizing a short ion chamber, as proposed by Dixon [Med. Phys. 30, 1272-1280 (2003)]. A more detailed set of guidelines for implementing such measurements is also presented in this paper. In addition, some fundamental principles governing CT dose which have not previously been clearly enunciated follow from the model, and a fundamental (energy-based) quantity dubbed 'CTDI-aperture' is introduced

  20. Skin dose measurement with MICROSPEC-2 trademark

    International Nuclear Information System (INIS)

    Hsu, H.H.

    1997-01-01

    For many years, the Eberline HP-260 trademark beta detectors were used for skin dose measurements at Los Alamos National Laboratory. This detector does not measure the beta spectrum and the skin dose can only be determined if the contaminating radioactive isotope is known. A new product MICROSPEC-2 trademark, has been developed which consists of a small portable computer with a multichannel analyzer and a beta probe consisting of a phoswich detector. The system measures the beta spectrum and automatically folds in the beta fluence-to-dose conversion function to yield the skin dose

  1. Radiologist and angiographic procedures. Absorbed radiation dose

    International Nuclear Information System (INIS)

    Tryhus, M.; Mettler, F.A. Jr.; Kelsey, C.

    1987-01-01

    The radiation dose absorbed by the angiographer during angiographic procedures is of vital importance to the radiologist. Nevertheless, most articles on the subject are incomplete, and few measure gonadal dose. In this study, three TLDs were used for each of the following sites: radiologist's eyes, thyroid, gonads with and without shielding apron, and hands. The average dose during carotid angiograms was 2.6, 4.1, 0.4, 4.7, and 7.1 mrads to the eyes, thyroid, gonads with and without .5 mm of lead shielding, and hands, respectively. Average dose during abdominal and peripheral vascular angiographic procedures was 5.2, 7.5, 1.2, 8.5, and 39.9 mrads to the eyes, thyroid, gonads with and without shielding, and hands, respectively. A literature review demonstrates a significant reduction in radiation dose to the angiographer after the advent of automated injectors. Our measured doses for carotid angiography are compatible with contemporary reported values. There was poor correlation with fluoroscopy time and measured dose to the angiographer

  2. CT dose profiles and MSAD calculation in a chest phantom

    International Nuclear Information System (INIS)

    Oliveira, Bruno Beraldo; Silva, Teogenes Augusto da

    2011-01-01

    For optimizing patient doses in computed tomography (CT), the Brazilian legislation has only established diagnostic reference levels (DRLs) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a quality control parameter for CT scanners. Compliance with the DRLs can be verified by measuring the Computed Tomography Air Kerma Index with a calibrated pencil ionization chamber or by obtaining the dose distribution in CT scans. An analysis of the quality of five CT scanners in Belo Horizonte was done in terms of dose profile of chest scans and MSAD determinations. Measurements were done with rod shape lithium fluoride thermoluminescent dosimeters (TLD-100) distributed in cylinders positioned in peripheral and central regions of a polymethylmethacrylate chest phantom. The peripheral regions presented higher dose values. The longitudinal dose variation can be observed and the maximum dose was recorded at the edges of the phantom at the midpoint of the longitudinal axis. The MSAD results were in according to the DRL of 25 mGy established by Brazilian legislation. The results contribute to disseminate to hospitals and radiologists the proper procedure to use the thermoluminescent dosimeters for the calculation of the MSAD from the CT dose profiles and to notice the compliance with the DRLs. (author)

  3. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  4. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  5. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  6. Problems in continuous dose rate measurement

    International Nuclear Information System (INIS)

    Yoshioka, Mitsuo

    1983-01-01

    The system of continuous dose rate measurement in Fukui Prefecture is described. A telemeter system was constructed in October, 1976, and it has been operated since 1977. Observation has been made at 11 observation stations in the Prefecture. In addition to the continuous measurement of dose rate by using NaI(T1)-DBM systems, the ionization chambers for high dose rate were installed, and also meteorological data have been collected. The detectors are covered with 1 mm thick aluminum designed so that the absorption of external radiation is kept as small as possible. To keep the environmental temperature of the detectors constant, constant temperature wind blow is made. With these consideration, the measurement of Xe-133 is possible, and the standard deviation of yearly dose is around 0.4 mR/Y. By measuring DBM transmission rate, the contribution of Xe-133, which comes from the exhaust pumps in power plants, can be detected. The problems of this system are as follows. First of all, the characteristics of the system must meet the purpose of dose monitoring. The system must detect the dose less than the target value to be achieved. The second is the selection of measuring systems to be set. The system is still not unified, and it is difficult to exchange data between different stations. Finally, the method of data analysis is not yet unified. Manuals or guide-books for this purpose are necessary for the mutual comparison of the data from the stations in different districts. (Kato, T.)

  7. Low-Dose Pulsatile Interleukin-6 As a Treatment Option for Diabetic Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    Gautam Ghatnekar

    2017-05-01

    Full Text Available Diabetic peripheral neuropathy (DPN remains one of the most common and serious complications of diabetes. Currently, pharmacological agents are limited to treating the pain associated with DPN, and do not address the underlying pathological mechanisms driving nerve damage, thus leaving a significant unmet medical need. Interestingly, research conducted using exercise as a treatment for DPN has revealed interleukin-6 (IL-6 signaling to be associated with many positive benefits such as enhanced blood flow and lipid metabolism, decreased chronic inflammation, and peripheral nerve fiber regeneration. IL-6, once known solely as a pro-inflammatory cytokine, is now understood to signal as a multifunctional cytokine, capable of eliciting both pro- and anti-inflammatory responses in a context-dependent fashion. IL-6 released from muscle in response to exercise signals as a myokine and as such has a unique kinetic profile, whereby levels are transiently elevated up to 100-fold and return to baseline levels within 4 h. Importantly, this kinetic profile is in stark contrast to long-term IL-6 elevation that is associated with pro-inflammatory states. Given exercise induces IL-6 myokine signaling, and exercise has been shown to elicit numerous beneficial effects for the treatment of DPN, a causal link has been suggested. Here, we discuss both the clinical and preclinical literature related to the application of IL-6 as a treatment strategy for DPN. In addition, we discuss how IL-6 may directly modulate Schwann and nerve cells to explore a mechanistic understanding of how this treatment elicits a neuroprotective and/or regenerative response. Collectively, studies suggest that IL-6, when administered in a low-dose pulsatile strategy to mimic the body’s natural response to exercise, may prove to be an effective treatment for the protection and/or restoration of peripheral nerve function in DPN. This review highlights the studies supporting this assertion and

  8. ''Nonisolated-sensor'' solid polystyrene absorbed dose measurements

    International Nuclear Information System (INIS)

    Zeitz, L.; Laughlin, J.S.

    1982-01-01

    A ''nonisolated-sensor'' solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation

  9. Nonisolated-sensor solid polystyrene absorbed dose measurements

    International Nuclear Information System (INIS)

    Zeitz, L.; Laughlin, J.S.

    1982-01-01

    A nonisolated-sensor solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation

  10. Assessment of peripheral skeletal muscle microperfusion in a porcine model of peripheral arterial stenosis by steady-state contrast-enhanced ultrasound and Doppler flow measurement.

    Science.gov (United States)

    Naehle, Claas P; Steinberg, Verena A; Schild, Hans; Mommertz, Gottfried

    2015-05-01

    Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 μg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no effect on

  11. Biological dose estimation and comet analysis of the victims in a high dose 60Co radiation accident

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Luo Yisheng; Li You; Yao Bo

    2007-01-01

    Objective: To explore the methods of chromosome preparation in human peripheral blood and bone marrow after very high dose exposure and fit the dose-response curve of dicentrics and tings in the range of high doses over 6 Gy for estimating biological dose and detecting DNA damage in the victims of '10.21' accident. Methods: The samples of peripheral blood and bone marrow in 2 victims were collected to prepare chromosome mataphases and dicentrics (multicentrics) + rings were counted. The dose-response curve and equation of human blood irradiated between 6-22 Gy in vitro were established and applied to assess biological dose of 2 victims. In addition, their DNA damages were tested by alkaline single cell gel electrophoresis. Results: The dicentric + ring numbers of 4.47 per cell in victims B's peripheral blood lymphocytes and 9.15 per cell in victim A's bone marrow who had no mitosis in peripheral blood cell. The whole body average doses of victims B and A estimated by 6-22 Gy equation arrived at 9.4 Gy and 19.5 Gy, respectively. The serious DNA damages were expressed by small head and large tail comet figures. Conclusions: The biological doses of 2 victims estimated by 6-22 Gy dose-response curve have reached the levels of extreme grave bone marrow and intestinal ARS, respectively. (authors)

  12. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  13. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  14. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M. (Universite du Quebec a Montreal (Canada))

    1989-10-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population.

  15. Mutant frequency of radiotherapy technicians appears to be associated with recent dose of ionizing radiation

    International Nuclear Information System (INIS)

    Messing, K.; Ferraris, J.; Bradley, W.E.; Swartz, J.; Seifert, A.M.

    1989-01-01

    The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population

  16. Peripheral chemoreflex inhibition with low-dose dopamine: new insight into mechanisms of extreme apnea.

    Science.gov (United States)

    Bain, Anthony R; Dujic, Zeljko; Hoiland, Ryan L; Barak, Otto F; Madden, Dennis; Drvis, Ivan; Stembridge, Mike; MacLeod, David B; MacLeod, Douglas M; Ainslie, Philip N

    2015-11-01

    The purpose of this study was to determine the impact of peripheral chemoreflex inhibition with low-dose dopamine on maximal apnea time, and the related hemodynamic and cerebrovascular responses in elite apnea divers. In a randomized order, participants performed a maximal apnea while receiving either intravenous 2 μg·kg(-1)·min(-1) dopamine or volume-matched saline (placebo). The chemoreflex and hemodynamic response to dopamine was also assessed during hypoxia [arterial O2 tension, (PaO2 ) ∼35 mmHg] and mild hypercapnia [arterial CO2 tension (PaCO2 ) ∼46 mmHg] that mimicked the latter parts of apnea. Outcome measures included apnea duration, arterial blood gases (radial), heart rate (HR, ECG), mean arterial pressure (MAP, intra-arterial), middle (MCAv) and posterior (PCAv) cerebral artery blood velocity (transcranial ultrasound), internal carotid (ICA) and vertebral (VA) artery blood flow (ultrasound), and the chemoreflex responses. Although dopamine depressed the ventilatory response by 27 ± 41% (vs. placebo; P = 0.01), the maximal apnea duration was increased by only 5 ± 8% (P = 0.02). The PaCO2 and PaO2 at apnea breakpoint were similar (P > 0.05). When compared with placebo, dopamine increased HR and decreased MAP during both apnea and chemoreflex test (P all breathe. Copyright © 2015 the American Physiological Society.

  17. Measurement of radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Helmrot, E.; Carlsson, G. A.

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs. (authors)

  18. Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2013-01-01

    Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret eq for scan modes involving table translation and the midpoint dose D L (0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret eq was calculated from CTDI 100 and ε(CTDI 100 ) (CTDI 100 efficiency), and D L (0) was calculated from D-caret eq and the approach to equilibrium function H(L) =D L (0)/D eq , where D eq was the equilibrium dose. CTDI 100 may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI Vol using the central to peripheral CTDI 100 ratio (R 100 ). The authors have provided the required ε(CTDI 100 ) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R 100 was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D L (0) and D L (0)/D eq in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret eq and D L (0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI 100 ) and H(L) data in two previous papers. R 100 is presented for a majority of multidetector CT scanners currently on the market, and can be

  19. Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit

    International Nuclear Information System (INIS)

    Kwak, Yong Kuk; Hong, Sun Gi; Ha, Min Yong; Park, Jang Pil; Yoo, Sook Hyun; Cho, Woong

    2015-01-01

    This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, F·S 5×5 cm)on a 5 cm acrylic phantom using the secondary shielding material of same condition, 3 mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8 cm Pb block to limit effect of leakage and transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Using human phantom, the Lens dose on IMRT treatment plan is 315.9 cGy and the real measurement value is 216.7 cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3 mm Pb plate and tungsten eye-shield block. When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator and MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection

  20. Dose measurements in pulsed radiation fields with commercially available measuring components

    International Nuclear Information System (INIS)

    Friedrich, Sabrina; Hupe, Oliver

    2016-01-01

    Dose measurements in pulsed radiation fields with dosemeters using the counting technique are known to be inappropriate. Therefore, there is a demand for a portable device able to measure the dose in pulsed radiation fields. As a detector, ionisation chambers seem to be a good alternative. In particular, using a secondary standard ionisation chamber in combination with a reliable charge-measuring system would be a good solution. The Physikalisch-Technische Bundesanstalt (PTB) uses secondary standard ionisation chambers in combination with PTB-made measuring electronics for dose measurements at its reference fields. However, for general use, this equipment is too complex. For measurements on-site, a mobile special electronic system [Hupe, O. and Ankerhold, U. Determination of ambient and personal dose equivalent for personnel and cargo security screening. Radiat. Prot. Dosim. 121(4), 429-437 (2006)] has been used successfully. Still, for general use, there is a need for a much simpler but a just as good solution. A measuring instrument with very good energy dependence for H*(10) is the secondary standard ionisation chamber HS01. An easy-to-use and commercially available electrometer for measuring the generated charges is the UNIDOS by PTW Freiburg. Depending on the expected dose values, the ionisation chamber used can be selected. In addition, measurements have been performed by using commercially available area dosemeters, e.g. the Mini SmartION 2120S by Thermo Scientific, using an ionisation chamber and the Szintomat 6134 A/H by Automess, using a scintillation detector. (authors)

  1. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  2. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  3. Out-of-field dose measurements in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kaderka, Robert

    2011-07-13

    This thesis describes the results from measurements of the out-of-field dose in radiotherapy. The dose outside the treatment volume has been determined in a water phantom and an anthropomorphic phantom. Measurements were performed with linac photons, passively delivered protons, scanned protons, passively delivered carbon ions as well as scanned carbon ions. It was found that the use of charged particles for radiotherapy reduces the out-of-field dose by up to three orders of magnitude compared to conventional radiotherapy with photons.

  4. Pathophysiology of Chemotherapy-Induced Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    Hana Starobova

    2017-05-01

    Full Text Available Chemotherapy-induced neuropathy is a common, dose-dependent adverse effect of several antineoplastics. It can lead to detrimental dose reductions and discontinuation of treatment, and severely affects the quality of life of cancer survivors. Clinically, chemotherapy-induced peripheral neuropathy presents as deficits in sensory, motor, and autonomic function which develop in a glove and stocking distribution due to preferential effects on longer axons. The pathophysiological processes are multi-factorial and involve oxidative stress, apoptotic mechanisms, altered calcium homeostasis, axon degeneration and membrane remodeling as well as immune processes and neuroinflammation. This review focusses on the commonly used antineoplastic substances oxaliplatin, cisplatin, vincristine, docetaxel, and paclitaxel which interfere with the cancer cell cycle—leading to cell death and tumor degradation—and cause severe acute and chronic peripheral neuropathies. We discuss drug mechanism of action and pharmacokinetic disposition relevant to the development of peripheral neuropathy, the epidemiology and clinical presentation of chemotherapy-induced neuropathy, emerging insight into genetic susceptibilities as well as current understanding of the pathophysiology and treatment approaches.

  5. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  6. Radiation-induced apoptosis of lymphocytes in peripheral blood

    International Nuclear Information System (INIS)

    Oh, Yoon Kyeong; Lee, Tae Bum; Nam, Taek Keun; Kee, Keun Hong; Choi, Cheol Hee

    2003-01-01

    This study quantitatively evaluated the apoptosis in human peripheral blood lymphocytes using flow cytometry, and investigated the possibility of using this method, with a small amount of blood, and the time and dose dependence of radiation-induced apoptosis. Peripheral blood lymphocytes were isolated from the heparinized venous blood of 11 healthy volunteers, 8 men and 3 women, with each 10 ml of blood being divided into 15 samples. The blood lymphocytes were irradiated using a linear accelerator at a dose rate of 2.4 Gy/min, to deliver doses of 0.5, 1, 2 and 5 Gy. The control samples, and irradiated cells, were maintained in culture medium for 24, 48 and 72 hours following the irradiation. The number of apoptotic cells after the in vitro X-irradiation was measured by flow cytometry after incubation periods of 24, 48 and 72 hours. We also observed the apoptotic cells using a DNA fragmentation assay and electron microscopy. The rate of spontaneous apoptosis increased in relation to the time interval following irradiation (1.761±0.161, 3.563±0.564, 11.098±2.849, at 24, 48, and 72 hours). The apoptotic cells also increased in the samples irradiated with 0.5, 1, 2 and 5 Gy, in a radiation dose and time interval after irradiation manner, with the apoptosis being too great at 72 hours after irradiation. The dose-response curves were characterized by an initial steep increase in the number of apoptotic cells for irradiation doses below 2 Gy, with a flattening of the curves as the dose approached towards 5 Gy. The flow cytometric assay technique yielded adequate data, and required less than 1 mL of blood. The time and dose dependence of the radiation-induced apoptosis, was also shown. It is suggested that the adequate time interval required for the evaluation of apoptosis would be 24 to 48 hours after blood sampling

  7. Chromosomal aberration in peripheral lymphocytes and doses to the active bone marrow in radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Gershkevitsh, E.; Trott, K.R.

    2002-01-01

    Purpose: Radiotherapy plays an important role in the management of prostate cancer. Epidemiological data indicate a small but significant risk of radiation-induced leukemia after radiotherapy which might be related to the high mean bone marrow dose associated with radiotherapy of prostate cancer. The purpose of the study was to investigate the relation between the mean bone marrow dose and unstable chromosome aberrations in peripheral blood lymphocytes in patients undergoing conformal radiotherapy for prostate cancer as a possible indicator of risk. Endometrial cancer patients were also included for comparison. Patients and Methods: Nine patients, six with prostate cancer (60-73 years old) and three with endometrial cancer (61-81 years old) treated with radiotherapy were included in the study. The non-bony spaces inside the pelvic bones were outlined on every CT slice using the treatment planning system and mean doses to the bone marrow calculated. Blood samples of the patients were obtained at different times before, during and at the end of treatment. Lymphocytes were cultured in the usual way and metaphases scored for dicentric aberrations. Results: 46 samples from nine patients were obtained. The mean number of metaphases analyzed per sample was 180 with a range from 52 to 435. The mean bone marrow doses for prostate cancer patients ranged from 2.8 to 4.2 Gy and for endometrial cancer patients from 12.8 to 14.8 Gy. The aberration yield increased with the planning target volume and the mean bone marrow dose. Conclusion: The yield of dicentric aberrations for prostate cancer patients correlated closely with the mean bone marrow dose albeit the induction of dicentrics occurred in mature T lymphocytes most of which were probably in transit through the irradiated volumes. Therefore, the observed relationship between dicentrics and mean bone marrow doses are indirect. (orig.) [de

  8. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    International Nuclear Information System (INIS)

    Han, Su Chul; Hong, Dong Hee

    2016-01-01

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures

  9. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  10. Normal tissue tolerance to external beam radiation therapy: Peripheral nerves

    International Nuclear Information System (INIS)

    Henriques de Figueiredo, B.; Dejean, C.; Sargos, P.; Kantor, G.; Huchet, A.; Mamou, N.; Loiseau, H.

    2010-01-01

    Plexopathies and peripheral neuropathies appear progressively and with several years delay after radiotherapy. These lesions are observed principally after three clinical situations: supraclavicular and axillar irradiations for breast cancer, pelvic irradiations for various pathologies and limb irradiations for soft tissue sarcomas. Peripheral nerves and plexus (brachial and lumbosacral) are described as serial structures and are supposed to receive less than a given maximum dose linked to the occurrence of late injury. Literature data, mostly ancient, define the maximum tolerable dose to a threshold of 60 Gy and highlight also a great influence of fractionation and high fraction doses. For peripheral nerves, most frequent late effects are pain with significant differences of occurrence between 50 and 60 Gy. At last, associated pathologies (diabetes, vascular pathology, neuropathy) and associated treatments have probably to be taken into account as additional factors, which may increase the risk of these late radiation complications. (authors)

  11. Assessment of concomitant testicular dose with radiochromic film

    International Nuclear Information System (INIS)

    Fricker, Katherine; Thompson, Christine; Meyer, Juergen

    2013-01-01

    To assess the suitability of EBT2 and XRQA2 Gafchromic film for measuring low doses in the periphery of treatment fields, and to measure the accumulative concomitant dose to the contralateral testis resulting from CT imaging, pre-treatment imaging (CBCT) and seminoma radiotherapy with and without gonadal shielding. Superficial peripheral dose measurements made using EBT2 Gafchromic film on the surface of water equivalent material were compared to measurements made with an ionisation chamber in a water phantom to evaluate the suitability and accuracy of the film dosimeter for such measurements. Similarly, XRQA2 was used to measure surface doses within a kilovoltage beam and compared with ionisation chamber measurements. Gafchromic film was used to measure CT, CBCT and seminoma treatment related testicular doses on an anthropomorphic phantom. Doses were assessed for two clinical plans, both with and without gonadal shielding. Testicular doses resulting from the treatment of up to 0.83 ± 0.17 Gy were measured per treatment. Additional doses of up to 0.49 ± 0.01 and 2.35 ± 0.05 cGy were measured per CBCT and CT image, respectively. Reductions in the testicular dose in the order of 10, 36 and 78 % were observed when gonadal shielding was fitted for treatment, CT and CBCT imaging, respectively. Gafchromic film was found to be suitable for measuring dose in the periphery of treatment fields. The dose to the testis should be limited to minimise the risk of radiation related side effects. This can be achieved by using appropriate gonadal shielding, irrespective of the treatment fields employed.

  12. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients.

    Science.gov (United States)

    Asadian, Simin; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Rezaei, Mansour

    2016-01-01

    An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients' body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (Ptemperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%). Paired t-test demonstrated an acceptable precision with forehead (P=0.132), left (P=0.18) and right (P=0.318) tympanic membranes, oral (P=1.00), and axillary (P=1.00) methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left) for assessing a patient's body temperature in the intensive care units because of high accuracy and acceptable precision.

  13. Thermoluminescent dosimeters for low dose X-ray measurements

    International Nuclear Information System (INIS)

    Del Sol Fernández, S.; García-Salcedo, R.; Sánchez-Guzmán, D.; Ramírez-Rodríguez, G.; Gaona, E.; León-Alfaro, M.A. de; Rivera-Montalvo, T.

    2016-01-01

    The response of TLD-100, CaSO_4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm"2 at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO_4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO_4:Dy showed a linearity from 0.1 to 60 mGy - Highlights: • Low dose X-ray doses for personal dosimetry were measured. • Radiation dose (µGy ) for environmental dosimetry were determined. • Scattering radiation dose were measured by TLDs. • Linearity of pair TLD system was successful in the range of microgray. • Pair TLDs composed by CaSO_4:Dy and by LiF:Mg,Cu,P. is suggested for clinical dosimetry.

  14. Low doses of a neonicotinoid insecticide modify pheromone response thresholds of central but not peripheral olfactory neurons in a pest insect.

    Science.gov (United States)

    Rabhi, Kaouther K; Deisig, Nina; Demondion, Elodie; Le Corre, Julie; Robert, Guillaume; Tricoire-Leignel, Hélène; Lucas, Philippe; Gadenne, Christophe; Anton, Sylvia

    2016-02-10

    Insect pest management relies mainly on neurotoxic insecticides, including neonicotinoids, leaving residues in the environment. There is now evidence that low doses of insecticides can have positive effects on pest insects by enhancing various life traits. Because pest insects often rely on sex pheromones for reproduction, and olfactory synaptic transmission is cholinergic, neonicotinoid residues could modify chemical communication. We recently showed that treatments with different sublethal doses of clothianidin could either enhance or decrease behavioural sex pheromone responses in the male moth, Agrotis ipsilon. We investigated now effects of the behaviourally active clothianidin doses on the sensitivity of the peripheral and central olfactory system. We show with extracellular recordings that both tested clothianidin doses do not influence pheromone responses in olfactory receptor neurons. Similarly, in vivo optical imaging does not reveal any changes in glomerular response intensities to the sex pheromone after clothianidin treatments. The sensitivity of intracellularly recorded antennal lobe output neurons, however, is upregulated by a lethal dose 20 times and downregulated by a dose 10 times lower than the lethal dose 0. This correlates with the changes of behavioural responses after clothianidin treatment and suggests the antennal lobe as neural substrate involved in clothianidin-induced behavioural changes. © 2016 The Author(s).

  15. Comparative effects of inhaled relatively insoluble forms of 90Y, 144Ce, and 90Sr on canine peripheral lymphocyte function

    International Nuclear Information System (INIS)

    Benjamin, S.A.; Jones, R.K.; Snipes, M.B.; Lustgarten, C.S.

    1976-01-01

    Dogs that have inhaled relatively insoluble forms of either alpha- or beta-emitting radionuclides manifest a peripheral lymphopenia, the development and course of which depends on both total dose and dose rate. The remaining peripheral lymphocytes in dogs exposed to longer lived beta-emitting radionuclides showed a depressed function as measured by the ability to respond to plant mitogens in vitro. This experiment was designed to evaluate the effect of dose rate on peripheral lymphocyte function by exposing dogs to aerosols of radionuclides with varied effective half-lives in the lung: 90 Y (2.6 days), 144 Ce (170 days), and 90 Sr (650 days). Three groups of four adult beagle dogs each were exposed by inhalation to 90 Y, 144 Ce, or 90 Sr in fused-clay particles. Two controls were matched with each group. Initial lung burdens and initial dose rates to the lung were 520 to 610 μCi/kg of body weight and 2200 to 2600 rads/day in the 90 Y group, 33 to 60 μCi/kg and 200 to 350 rads/day in the 144 Ce group, and 25 to 32 μCi/kg and 130 to 170 rads/day in the 90 Sr group. Hematologic parameters and lymphocyte function as measured by the ability of lymphocytes to respond to plant mitogen stimulation were evaluated on a weekly or biweekly basis for 8 weeks after exposure and on a monthly basis thereafter. The 90 Y-exposed dogs showed a marked lymphopenia within 1 week with a return to control levels by 20 weeks after exposure. The remaining peripheral lymphocytes, however, showed no functional changes in these dogs. Animals exposed to 144 Ce or 90 Sr developed a progressive and persisent lymphopenia and showed functional depression of the remaining lymphocytes as well. The relationships among dose pattern, lymphopenia, and lymphocyte-function depression are discussed

  16. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  17. Dose Assessment using Chromosome Aberration Analyses in Human Peripheral Blood Lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Tae Ho; Kim, Jin-Hong; Kim, Jin Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The healthy five donors were recruited to establish the dose-response calibration curve for chromosomal aberrations by ionizing radiation exposure. Our cytogenetic results revealed that the mean frequency of chromosome aberration increased with increasing radiation dose. In this study, dicentric assay and CBMN assay were compared considering the sensitivity and accuracy of dose estimation. Therefore, these chromosome aberration analyses will be the foundation for biological dosimetric analysis with additional research methods such as translocation and PCC assay. The conventional analysis of dicentric chromosomes in HPBL was suggested by Bender and Gooch in 1962. This assay has been for many years, the golden standard and the most specific method for ionizing radiation damage. The dicentric assay technique in HPBL has been shown as the most sensitive biological method and reliable bio-indicator of quantifying the radiation dose. In contrast, the micronucleus assay has advantages over the dicentric assay since it is rapid and requires less specialized expertise, and accordingly it can be applied to monitor a big population. The cytokinesis-block micronucleus (CBMN) assay is a suitable method for micronuceli measurement in cultured human as well as mammalian cells. The aim of our study was to establish the dose response curve of radiation-induced chromosome aberrations in HPBL by analyzing the frequency of dicentrics and micronuclei.

  18. Passive Rn dose meters - measuring methods appropriate for large measurement series

    International Nuclear Information System (INIS)

    Urban, M.; Kiefer, H.

    1985-01-01

    Passive integrating measuring methods can be classified in several groups by their functioning principle, e.g. spray chambers or open chambers with nuclear trace detectors or TL detectors, open detectors, activated carbon dose meters with or without TL detectors. According to the functioning principle, only radon or radon and fission products can be detected. The lecture gives a survey of the present state of development of passive Rn dose meters. By the example of the Ra dose meter developed at Karlsruhe which was used in inquiry measurements carried out in Germany, Switzerland, the Netherlands, Belgium and Austria, etching technology, estimation of measuring uncertainties, reproducibility and fading behaviour shall be discussed. (orig./HP) [de

  19. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  20. Dose measurement method suitable for management of food irradiation

    International Nuclear Information System (INIS)

    Tanaka, Ryuichi

    1990-01-01

    The report describes major features of dose measurement performed for the management of food irradiation processes, and dose measuring methods suitable for this purpose, and outlines some activities for establishing international standards for dose measurement. Traceability studies made recently are also reviewed. Compared with the sterilization of medical materials, food irradiation is different in some major points from a viewpoint of dose measurement: foods can undergo significant changes in bulk density, depending on its properties, during irradiation, and the variation in the uniformity of bulk density can be large within an irradiation unit and among different units. An accurate dosimeter and well-established traceability are essential for food irradiation control, and basically a dosimeter should be high in reproducibility and stable in dose response, and should be easy to readjust for eliminating systematic errors. A new type of dosimeter was developed recently, in which ESR is used to measure the free radicals generated by radiations in crystals of alanine, an amino acid. Standardization of large dose measurement procedures has been carried out by committee E10 set up under ASTM. (N.K.)

  1. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  2. Radiotherapy after high-dose chemotherapy and peripheral blood stem cell support in high-risk breast cancer

    International Nuclear Information System (INIS)

    Hoeller, Ulrike; Heide, Juergen; Kroeger, Nicolaus; Krueger, William; Jaenicke, Fritz; Alberti, Winfried

    2002-01-01

    Purpose: To assess the toxicity and efficacy of radiotherapy with respect to locoregional control after adjuvant high-dose chemotherapy for patients with breast cancer. At first, radiotherapy was withheld because of toxicity concerns, but it was introduced in 1995 because of reported high locoregional relapse rates. Methods and Materials: Between 1992 and 1998, 40 patients with Stage II-III high-risk breast cancer received adjuvant high-dose chemotherapy consisting of thiotepa, mitoxantrone, and cyclophosphamide and peripheral blood stem cell support after four cycles of induction chemotherapy. The chest wall or breast, as well as the supraclavicular nodes, were irradiated with electrons and photons to a median dose of 50.4 Gy in 20 patients. Six additional patients received only supraclavicular irradiation to a median dose of 50.4 Gy. Acute toxicity was scored clinically. Pulmonary function tests were performed in 14 irradiated patients before high-dose chemotherapy and 1.1-4.4 years (median 1.6) after irradiation. The median follow-up time of living patients was 33 vs. 67 months in irradiated (n=26) and nonirradiated (n=14) patients, respectively. Results: G2 and G3 hematologic toxicity occurred in 1 patient each. No clinical pneumonitis or clinical impairment of lung function was observed. After 1-2 years, the lung function tests showed only minor changes in 4 patients. The 3-year locoregional control rate was 92% in the irradiated patients vs. 58% in the nonirradiated patients (p=0.049, actuarial analysis). Conclusion: In this series, adjuvant radiotherapy after adjuvant chemotherapy for breast cancer appeared well tolerated, with improved local regional control and without significant side effects. Longer follow-up and more patient accrual, as well as Phase III trials, are necessary for confirmation

  3. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  4. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  5. Electrophysiological measurements of diabetic peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Shabeeb, Dheyauldeen; Najafi, Masoud; Hasanzadeh, Gholamreza; Hadian, Mohammed Reza; Musa, Ahmed Eleojio; Shirazi, Alireza

    2018-03-28

    Peripheral neuropathy is one of the main complications of diabetes mellitus. One of the features of diabetic nerve damage is abnormality of sensory and motor nerve conduction study. An electrophysiological examination can be reproduced and is also a non-invasive approach in the assessment of peripheral nerve function. Population-based and clinical studies have been conducted to validate the sensitivity of these methods. When the diagnosis was based on clinical electrophysiological examination, abnormalities were observed in all patients. In this research, using a review design, we reviewed the issue of clinical electrophysiological examination of diabetic peripheral neuropathy in articles from 2008 to 2017. For this purpose, PubMed, Scopus and Embase databases of journals were used for searching articles. The researchers indicated that diabetes (both types) is a very disturbing health issue in the modern world and should be given serious attention. Based on conducted studies, it was demonstrated that there are different procedures for prevention and treatment of diabetes-related health problems such as diabetic polyneuropathy (DPN). The first objective quantitative indication of the peripheral neuropathy is abnormality of sensory and motor nerve conduction tests. Electrophysiology is accurate, reliable and sensitive. It can be reproduced and also is a noninvasive approach in the assessment of peripheral nerve function. The methodological review has found that the best method for quantitative indication of the peripheral neuropathy compared with all other methods is clinical electrophysiological examination. For best results, standard protocols such as temperature control and equipment calibration are recommended. Copyright © 2018. Published by Elsevier Ltd.

  6. Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries

    NARCIS (Netherlands)

    Westenberg, J.J.M.; Geest, van der R.J.; Wasser, M.N.J.M.; Linden, van der E.L.; Walsum, van T.; Assen, van H.C.; Roos, de A.; Vanderschoot, J.; Reiber, J.H.C.

    2000-01-01

    In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semi-automatically in maximum intensity

  7. Early morphologic and quantitative changes in mouse peripheral blood lymphocytes after low dose gamma-irradiation

    International Nuclear Information System (INIS)

    Gitsov, L.; Byrneva, V.; Goranov, I.

    1979-01-01

    The study was undertaken in an effort to establish differences in the radiosensitivity of peripheral blood lymphocytes, as a possible test for evaluation of early and discrete radiation injury. Sexually mature mice of BAIB/c line were X-irradiated with doses of 50 and 250 rad. The animals were sacrificed by blood letting 24 hours after irradiation, but 30 minutes before this each mouse was heparinized. Smears were prepared from the enriched pooled leucocyte suspensions, obtained by dextran sedimentation of the red cells. The preparations were stained with toluidin blue by the methods of Smetana and Pappenheim. Cell size, clasmatosis, nucleolar structure and degree of cytoplasmic metachromasia were determined. It was found that the lymphocytogram of animals irradiated with 50 rad was characterized by high percentage of small lymphocytes, most of them with dispersed nuclear ribonucleoproteins and minimal clasmatose activity. Irradiation with 100 rad induced a characteristical rise in lymphocyte clasmatose activity and decrease in the number of small lymphocytes. The nucleoli were bright and well delineated. The lymphocytogram of animals irradiated with higher doses (150 and 250 rad) was characterized by predomination of large lymphocytes and hyperbasophilic forms with well preserved bright nucleoli. The percentage of lymphocates with clasmatosis was below the control value. (A.B.)

  8. Endogenous peripheral oxytocin measures can give insight into the dynamics of social relationships: a review

    Directory of Open Access Journals (Sweden)

    Catherine eCrockford

    2014-03-01

    Full Text Available The neuropeptide, oxytocin, receives increasing attention due to its role in stress regulation and promoting affiliative social behavior. Research across mammals points to a complex pattern whereby social context and individual differences moderate the endogenous release of oxytocin as well as moderate the effects that exogenous administration of oxytocin has on social behavior. In addition to measuring central release of oxytocin or exogenous administration of oxytocin on social behavior, for example via inhalation, it is becoming evident that measuring endogenous peripheral oxytocin levels is an additional, informative tool. This is particularly so when oxytocin can be measured from non-invasively collected samples, such as in urine. Although it is still debated as to whether peripheral measures of oxytocin relate to central measures of oxytocin, anatomical and functional evidence indicate a link between the two. We argue that non-invasive measures of peripheral oxytocin hold several research and potential therapeutic advantages. Principally, study subjects can be sampled repeatedly in different social contexts where social history between interaction partners can be taken into account. Several hormones can be measured simultaneously allowing examination of the influence of oxytocin interactions with other hormones on motivational states. Valence of relationships as well as changes in relationship quality over time can be measured through endocrine responses. Also, the approach of identifying natural social contexts that are associated with endogenous oxytocin release offers the potential of behavioral therapy as an addition or alternative to chemical therapy in the field of mental health.

  9. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  10. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  11. Measurement of gamma radiation doses in nuclear power plant environment

    International Nuclear Information System (INIS)

    Bochvar, I.A.; Keirim-Markus, I.B.; Sergeeva, N.A.

    1976-01-01

    Considered are the problems of measuring gamma radiation dose values and the dose distribution in the nuclear power plant area with the aim of estimating the extent of their effect on the population. Presented are the dosimeters applied, their distribution throughout the controlled area, time of measurement. The distribution of gamma radiation doses over the controlled area and the dose alteration with the increase of the distance from the release source are shown. The results of measurements are investigated. The conclusion is made that operating nuclear power plants do not cause any increase in the gamma radiation dose over the area. Recommendations for clarifying the techniques for using dose-meters and decreasing measurement errors are given [ru

  12. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  13. Radiation Dose Measurement Using Chemical Dosimeters

    International Nuclear Information System (INIS)

    Lee, Min Sun; Kim, Eun Hee; Kim, Yu Ri; Han, Bum Soo

    2010-01-01

    The radiation dose can be estimated in various ways. Dose estimates can be obtained by either experiment or theoretical analysis. In experiments, radiation impact is assessed by measuring any change caused by energy deposition to the exposed matter, in terms of energy state (physical change), chemical production (chemical change) or biological abnormality (biological change). The chemical dosimetry is based on the implication that the energy deposited to the matter can be inferred from the consequential change in chemical production. The chemical dosimetry usually works on the sample that is an aqueous solution, a biological matter, or an organic substance. In this study, we estimated absorbed doses by quantitating chemical changes in matter caused by radiation exposure. Two different chemical dosimeters, Fricke and ECB (Ethanol-Chlorobenzene) dosimeter, were compared in several features including efficacy as dose indicator and effective dose range

  14. Studying and measuring the gamma radiation doses in Homs city

    International Nuclear Information System (INIS)

    Sofaan, A. H.

    2001-01-01

    The gamma radiation dose was measured in Homs city by using many portable dosimeters (electronic dosimeter and Geiger-Muller). The measurements were carried out in the indoor and outdoor buildings, for different time period, through one year (1999-2000). High purity germanium detector with low back ground radiation (HpGe) was used to determine radiation element contained in some building and the surrounding soil. The statistical analysis laws were applied to make sure that the measured dose distribution around average value is normal distribution. The measurement indicates that the gamma indoor dose varies from 312μSv/y to 511μSv/y, with the average annual dose of 385μSv/y. However the gamma outdoor dose rate varies from 307μSv/y to 366μSv/y with an average annual dose 385μSv/y. The annual outdoor gamma radiation dose is about %16 lower than the outdoor dose in Homs City. These measurements have indicated that environmental gamma doses in Homs City are relatively low. This is because that most of the soils and rocks in the area are limestone. (author)

  15. Thermoluminescent dose measurements on board Salyut type orbital stations

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Arkhangelskij, V.V.; Aleksandrov, A.P.

    1984-06-01

    A small, vibration- and shock-resistant thermoluminescent dosemeter (TLD) system - named PILLE - was developed for orbital stations at the Central Research Institute for Physics, Hungary, to measure the cosmic radiation dose on-board. The first on-board measurements with this system were performed by B. Farkas, the Hungarian astronaut, on the Salyut-6 space station in 1980. The same instrument was used by other crews in the following years. Doses measured at different sites in Salyut-6 are presented. The dose rates varied from 0.7 to 0.11 mGy.day -1 . After the first cosmic measurements, the system was further developed. The minimum detectable dose of the new TLD system is 1 μGy, i.e. less by one order of magnitude than that of the former system. The self-irradiation dose rate of the TLD bulbs is also reduced by more than an order of magnitude to 10 nGy.h -1 , by use of potassium-free glass for the bulb envelope. This new type of PILLE TLD system is currently on-board Salyut-7. The dose rates (0.12-0.23 mGy.day -1 ) measured in 1983 are presented in detail. (author)

  16. Peripheral phlebitis: a point-prevalence study.

    Science.gov (United States)

    Washington, Georgita T; Barrett, Robin

    2012-01-01

    The purpose of this research study was to determine the factors influencing peripheral phlebitis in the adult medical-surgical population. The authors would then be able to use those data to determine whether a change in practice was warranted. Data collection and analysis of 188 intravenous sites revealed that females with higher doses of medications in intravenous sites of longer dwell times and suboptimal nutrition were at greater risk of developing peripheral phlebitis. The point prevalence was greater than the recommended 5%, which led the authors to review their facility's patient care and documentation practices.

  17. Difference between ejection times measured at two different peripheral locations as a novel marker of vascular stiffness.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Pulse wave velocity (PWV has been recommended as an arterial damage assessment tool and a surrogate of arterial stiffness. However, the current technology does not allow to measure PWV both continuously and in real-time. We reported previously that peripherally measured ejection time (ET overestimates ET measured centrally. This difference in ET is associated with the inherent vascular properties of the vessel. In the current study we examined ETs derived from plethysmography simultaneously at different peripheral locations and examined the influence of the underlying arterial properties on ET prolongation by changing the subject's position. We calculated the ET difference between two peripheral locations (ΔET and its corresponding PWV for the same heartbeat. The ΔET increased with a corresponding decrease in PWV. The difference between ΔET in the supine and standing (which we call ET index was higher in young subjects with low mean arterial pressure and low PWV. These results suggest that the difference in ET between two peripheral locations in the supine vs standing positions represents the underlying vascular properties. We propose ΔET in the supine position as a potential novel real-time continuous and non-invasive parameter of vascular properties, and the ET index as a potential non-invasive parameter of vascular reactivity.

  18. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  19. The Design of a γ-dose rate monitoring meter Based on C8051F020

    International Nuclear Information System (INIS)

    Tan Wei; Liu Chong; Wu Longxiong; Yang Binhua

    2009-01-01

    This paper presents the design of γ-dose-rate monitoring meter based on C8051F020 single chip microcomputer (SCM), and also describes the solution of hardware and software. The peripheral circuit of USB is also included. This meter can rapidly measure γ-dose-rate and store more data in power failure. In addition, it is featured with low power, small size, strong anti-interference and accurate measurement. (authors)

  20. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  1. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  2. Simplified methods for in vivo measurement of acetylcholinesterase activity in rodent brain

    International Nuclear Information System (INIS)

    Kilbourn, Michael R.; Sherman, Phillip S.; Snyder, Scott E.

    1999-01-01

    Simplified methods for in vivo studies of acetylcholinesterase (AChE) activity in rodent brain were evaluated using N-[ 11 C]methylpiperidinyl propionate ([ 11 C]PMP) as an enzyme substrate. Regional mouse brain distributions were determined at 1 min (representing initial brain uptake) and 30 min (representing trapped product) after intravenous [ 11 C]PMP administration. Single time point tissue concentrations (percent injected dose/gram at 30 min), tissue concentration ratios (striatum/cerebellum and striatum/cortex ratios at 30 min), and regional tissue retention fractions (defined as percent injected dose 30 min/percent injected dose 1 min) were evaluated as measures of AChE enzymatic activity in mouse brain. Studies were carried out in control animals and after dosing with phenserine, a selective centrally active AChE inhibitor; neostigmine, a peripheral cholinesterase inhibitor; and a combination of the two drugs. In control and phenserine-treated animals, absolute tissue concentrations and regional retention fractions provide good measures of dose-dependent inhibition of brain AChE; tissue concentration ratios, however, provide erroneous conclusions. Peripheral inhibition of cholinesterases, which changes the blood pharmacokinetics of the radiotracer, diminishes the sensitivity of all measures to detect changes in central inhibition of the enzyme. We conclude that certain simple measures of AChE hydrolysis rates for [ 11 C]PMP are suitable for studies where alterations of the peripheral blood metabolism of the tracer are kept to a minimum

  3. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  4. Clinical toxicity of peripheral nerve to intraoperative radiotherapy in a canine model

    International Nuclear Information System (INIS)

    Johnstone, Peter A. S.; DeLuca, Anne Marie; Bacher, John D.; Hampshire, Victoria A.; Terrill, Richard E.; Anderson, William J.; Kinsella, Timothy J.; Sindelar, William F.

    1995-01-01

    Purpose: The clinical late effects of intraoperative radiotherapy (IORT) on peripheral nerve were investigated in a foxhound model. Methods and Materials: Between 1982 and 1987, 40 animals underwent laparotomy with intraoperative radiotherapy of doses from 0-75 Gy administered to the right lumbosacral plexus. Subsequently, all animals were monitored closely and sacrificed to assess clinical effects to peripheral nerve. This analysis reports final clinical results of all animals, with follow-up to 5 years. Results: All animals treated with ≥ 25 Gy developed ipsilateral neuropathy. An inverse relationship was noted between intraoperative radiotherapy dose and time to neuropathy, with an effective dose for 50% paralysis (ED 50 ) of 17.2 Gy. One of the animals treated with 15 Gy IORT developed paralysis, after a much longer latency than the other animals. Conclusions: Doses of 15 Gy delivered intraoperatively may be accompanied by peripheral neuropathy with long-term follow-up. This threshold is less than that reported with shorter follow-up. The value of ED 50 determined here is in keeping with data from other animal trials, and from clinical trials in humans

  5. The minimum measurable dose of the sensitive Harshaw TLDs

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1991-01-01

    The TL-dose response was measured for the sensitive Harshaw manufactured phosphors (CaF 2 :Dy and CaF 2 :Tm), taking chips from the same batch and from different batches. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses were derived and compared to the minimum measurable dose calculated by taking 3 times the standard deviation of unirradiated chips. The contribution of the individual calibration of each TLD chip was checked, as well

  6. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  7. Student's music exposure: Full-day personal dose measurements.

    Science.gov (United States)

    Washnik, Nilesh Jeevandas; Phillips, Susan L; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.

  8. Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-07-15

    Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement

  9. The Effect of Peripheral CRF Peptide and Water Avoidance Stress on Colonic and Gastric Transit in Guinea Pigs.

    Science.gov (United States)

    Hussain, Zahid; Kim, Hae Won; Huh, Cheal Wung; Lee, Young Ju; Park, Hyojin

    2017-07-01

    Functional dyspepsia (FD) and irritable bowel syndrome (IBS) are common gastrointestinal (GI) diseases; however, there is frequent overlap between FD and IBS patients. Emerging evidence links the activation of corticotropin releasing factor (CRF) receptors with stress-related alterations of gastric and colonic motor function. Therefore, we investigated the effect of peripheral CRF peptide and water avoidance stress (WAS) on upper and lower GI transit in guinea pigs. Dosages 1, 3, and 10 μg/kg of CRF were injected intraperitoneally (IP) in fasted guinea pigs 30 minutes prior to the intragastric administration of charcoal mix to measure upper GI transit. Colonic transits in non-fasted guinea pigs were assessed by fecal pellet output assay after above IP CRF doses. Blockade of CRF receptors by Astressin, and its effect on GI transit was also analyzed. Guinea pigs were subjected to WAS to measure gastrocolonic transit in different sets of experiments. Dose 10 μg/kg of CRF significantly inhibited upper GI transit. In contrast, there was dose dependent acceleration of the colonic transit. Remarkably, pretreatment of astressin significantly reverses the effect of CRF peptide on GI transit. WAS significantly increase colonic transit, but failed to accelerate upper GI transit. Peripheral CRF peptide significantly suppressed upper GI transit and accelerated colon transit, while central CRF involved WAS stimulated only colonic transit. Therefore, peripheral CRF could be utilized to establish the animal model of overlap syndrome. © Copyright: Yonsei University College of Medicine 2017.

  10. Expression of Cellular Isoform of Prion Protein on the Surface of Peripheral Blood Lymphocytes Among Women Exposed to Low Doses of Ionizing Radiation

    International Nuclear Information System (INIS)

    Klucinski, P.; Martirosian, G.; Mazur, B.; Kaufman, J.; Hrycek, A.; Masluch, E.; Cieslik, P.

    2007-01-01

    Ionizing radiation affect the expression of adhesive and co-stimulation molecules in lymphocytes. The objective of this study was to determinate the effect of low doses of ionizing radiation on the expression of prion protein PrPc on the surface peripheral blood lymphocytes in the women operating X-ray equipment. In female workers and persons of the control group the PrPc expression on CD3 (T-lymphocytes), Cd4 (T-helper), CD8 (T-cytotoxic) and CD19 (B- lymphocytes), were tested. We conclude that in women operating X-ray equipment the relationship between low doses of ionizing radiation and expression of PrPc on lymphocytes does exist concerning CD3, CD4 and CD lymphocytes. (author)

  11. The measurement of patient doses from diagnostic x-rays

    International Nuclear Information System (INIS)

    Morris, N.D.; Solomon, S.B.

    1980-06-01

    As part of the National Health and Medical Research Council survey to determine the genetic and mean bone-marrow doses to the Australian population from the medical, dental and chiropractic uses of radiation sources, doses to patients undergoing X-ray diagnostic procedures were evaluated. The doses were measured using capsules of LiF or CaF 2 :Dy thermoluminescent dosemeters (TLD). The evaluation of the TLD measurements is described and the mean values of the skin doses for patients undergoing various radiographic examinations in Australia in 1970 are presented

  12. Online radiation dose measurement system for ATLAS experiment

    International Nuclear Information System (INIS)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Bronner, J.; Hartet, J.; Franz, S.

    2009-01-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO 2 will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10 9 n/cm 2 for NIEL (non-ionizing energy loss) measurements, 10 12 n/cm 2 for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  13. Chromosomal aberrations in lymphocytes of peripheral blood among mayak facility workers who inhaled insoluble forms of 239Pu

    International Nuclear Information System (INIS)

    Okladnikova, N. D.; Scott, B. R.; Tokarskaya, Z. B.; Zhuntova, G. V.; Khokhryakov, V. F.; Syrchikov, V. A.; Grigoryeva, E. S.

    2005-01-01

    A cytogenetic study was performed on 79 plutonium (Pu) workers chronically exposed to alpha radiation from inhaled, low-transportable (insoluble) compounds of airborne 239 Pu and to external gamma rays. Body burden estimates for 239 Pu ranged from 0 to 15.5 kBq. Chromosomal aberrations (CAs) (stable and unstable among peripheral blood lymphocytes and cumulative alpha radiation doses were evaluated ∼25 y after first contact with 239 Pu. For the cytogenetic analyses, a standard two-day peripheral blood lymphocyte culture technique was applied. While alpha radiation doses continually increase up to the time of cytogenetic measurements, significant gamma ray exposures essentially ceased long before the time of measurement, so that alpha and gamma doses were not correlated. For the exposed workers, the mean 239 Pu body burden (estimate), evaluated at the time of the cytogenetic measurement, was 1.23 ± 0.26 kBq and the corresponding mean absorbed external gamma ray dose (estimate) to the total body was 0.076 ± 0.009 Gy. Single and multivariate regression analyses were performed on the CA data. Stable, unstable and total aberrations increased as the 239 Pu body burden increased over the range 0-4.5 kBq. However, above this range little additional increase was observed. CAs were weakly correlated with time since the first intake of 239 Pu. No relationship between chromatid aberrations and 239 Pu incorporation was found. Unstable (but not stable) aberrations were correlated with gamma radiation dose. No significant relationship of CA and smoking was found. (authors)

  14. Measurement of dosimetric parameters and dose verification in stereotactic radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Reduan Abdullah; Nik Ruzman Nik Idris; Ahmad Lutfi Yusof; Mazurawati Mohamed

    2013-01-01

    Full-text: The purpose of this study was to measure the dosimetric parameters for small photon beams to be used as input data treatment planning computer system (TPS) and to verify dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were Percentage Depth Dose (PDD), Off-axis Ratio (OAR), and Scatter Factor of Relative Output Factor. Small beams of 5 mm to 45 mm diameter circular cone collimators used in SRS were utilized for beam data measurements measured using pinpoint 3D ionization chamber (0.016 cc). For second part of this study, we reported the important quality assurance (QA) procedures before SRS treatment that influenced the dose delivery. These QA procedures consist of measurements on the accuracy in target localization and room laser alignment. The dose calculated to be delivered for treatment was verified using pinpoint 3D ionization chamber and TLD 100H. The mean deviation of measured dose using TLD 100H compared to calculated dose was 3.37 %. Beside that, pinpoint ionization 3D chamber give more accurate results of dose compared to TLD 100H. The measured dose using pinpoint 3D ionization chamber are good agreement with calculated dose by TPS with deviation of 2.17 %. The results are acceptable such as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1993) that dose delivered to the target volume must be within ±5 % error. (author)

  15. Accuracy and precision of four common peripheral temperature measurement methods in intensive care patients

    Directory of Open Access Journals (Sweden)

    Asadian S

    2016-09-01

    Full Text Available Simin Asadian,1 Alireza Khatony,1 Gholamreza Moradi,2 Alireza Abdi,1 Mansour Rezaei,3 1Nursing and Midwifery School, Kermanshah University of Medical Sciences, 2Department of Anesthesiology, 3Biostatistics & Epidemiology Department, Kermanshah University of Medical Sciences, Kermanshah, Iran Introduction: An accurate determination of body temperature in critically ill patients is a fundamental requirement for initiating the proper process of diagnosis, and also therapeutic actions; therefore, the aim of the study was to assess the accuracy and precision of four noninvasive peripheral methods of temperature measurement compared to the central nasopharyngeal measurement. Methods: In this observational prospective study, 237 patients were recruited from the intensive care unit of Imam Ali Hospital of Kermanshah. The patients’ body temperatures were measured by four peripheral methods; oral, axillary, tympanic, and forehead along with a standard central nasopharyngeal measurement. After data collection, the results were analyzed by paired t-test, kappa coefficient, receiver operating characteristic curve, and using Statistical Package for the Social Sciences, version 19, software. Results: There was a significant meaningful correlation between all the peripheral methods when compared with the central measurement (P<0.001. Kappa coefficients showed good agreement between the temperatures of right and left tympanic membranes and the standard central nasopharyngeal measurement (88%. Paired t-test demonstrated an acceptable precision with forehead (P=0.132, left (P=0.18 and right (P=0.318 tympanic membranes, oral (P=1.00, and axillary (P=1.00 methods. Sensitivity and specificity of both the left and right tympanic membranes were more than for other methods. Conclusion: The tympanic and forehead methods had the highest and lowest accuracy for measuring body temperature, respectively. It is recommended to use the tympanic method (right and left for

  16. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  17. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  18. Remote control and data processing for measurement of radiation dose

    International Nuclear Information System (INIS)

    Zhou Yu; Luo Yisheng; Guo Yong; Ji Gang; Wang Xinggong; Zhang Hong; Zhang Wenzhong

    2004-01-01

    Objective: To protect the workers from the reactor radiation and to improve the accuracy and efficiency of neutron dose measurement. Methods: With the application of remote control technology, a remote control and automatic measurement system for radiation dose measurement(especially for neutron dose) was set up. A Model 6517A electrometer was operated all automatically over RS-232 serial interface using SCPI commands with a computer. Results: The workers could stay far from the reactor and be able to control the portable computer in site though internet or LAN and then to control the 6517A electrometer to implement the dose measurement. After the measurement, the data were transferred to the remote computer near the workers and shared by many experts at the first time through the net. Conclusion: This is the first time that the remote control technology is applied in radiation dose measurement, which has so far been considered can only be performed at a near place. This new system can meet the need of neutron radiobiology researches as well as of the safety and health of the workers. (author)

  19. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  20. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  1. BeO-OSL detectors for dose measurements in cell cultures

    International Nuclear Information System (INIS)

    Andreeff, M.; Freudenberg, R.; Kotzerke, J.; Sommer, D.; Reichelt, U.; Henniger, J.

    2009-01-01

    Aim: The absorbed dose is an important parameter in experiments involving irradiation of cells in vitro with unsealed radionuclides. Typically, this is estimated with a model calculation, although the results thus obtained cannot be verified. Generally used real-time measurement methods are not applicable in this setting. A new detector material with in vitro suitability is the subject of this work. Methods: Optically-stimulated luminescence (OSL) dosimeters based on beryllium oxide (BeO) were used for dose measurement in cell cultures exposed to unsealed radionuclides. Their qualitative properties (e. g. energy-dependent count rate sensitivity, fading, contamination by radioactive liquids) were determined and compared to the results of a Monte Carlo simulation (using AMOS software). OSL dosimeters were tested in common cell culture setups with a known geometry. Results: Dose reproducibility of the OSL dosimeters was ± 1.5%. Fading at room temperature was 0.07% per day. Dose loss (optically-stimulated deletion) under ambient lighting conditions was 0.5% per minute. The Monte Carlo simulation for the relative sensitivity at different beta energies provided corresponding results to those obtained with the OSL dosimeters. Dose profile measurements using a 6 well plate and 14 ml PP tube showed that the geometry of the cell culture vessel has a marked influence on dose distribution with 188 Re. Conclusion: A new dosimeter system was calibrated with β-emitters of different energy. It turned out as suitable for measuring dose in liquids. The dose profile measurements obtained are suitably precise to be used as a check against theoretical dose calculations. (orig.)

  2. Simplified methods for in vivo measurement of acetylcholinesterase activity in rodent brain

    Energy Technology Data Exchange (ETDEWEB)

    Kilbourn, Michael R. E-mail: mkilbour@umich.edu; Sherman, Phillip S.; Snyder, Scott E

    1999-07-01

    Simplified methods for in vivo studies of acetylcholinesterase (AChE) activity in rodent brain were evaluated using N-[{sup 11}C]methylpiperidinyl propionate ([{sup 11}C]PMP) as an enzyme substrate. Regional mouse brain distributions were determined at 1 min (representing initial brain uptake) and 30 min (representing trapped product) after intravenous [{sup 11}C]PMP administration. Single time point tissue concentrations (percent injected dose/gram at 30 min), tissue concentration ratios (striatum/cerebellum and striatum/cortex ratios at 30 min), and regional tissue retention fractions (defined as percent injected dose 30 min/percent injected dose 1 min) were evaluated as measures of AChE enzymatic activity in mouse brain. Studies were carried out in control animals and after dosing with phenserine, a selective centrally active AChE inhibitor; neostigmine, a peripheral cholinesterase inhibitor; and a combination of the two drugs. In control and phenserine-treated animals, absolute tissue concentrations and regional retention fractions provide good measures of dose-dependent inhibition of brain AChE; tissue concentration ratios, however, provide erroneous conclusions. Peripheral inhibition of cholinesterases, which changes the blood pharmacokinetics of the radiotracer, diminishes the sensitivity of all measures to detect changes in central inhibition of the enzyme. We conclude that certain simple measures of AChE hydrolysis rates for [{sup 11}C]PMP are suitable for studies where alterations of the peripheral blood metabolism of the tracer are kept to a minimum.

  3. Cytogenetics dosimetry: dose-response curve for low doses of X-ray

    International Nuclear Information System (INIS)

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon; Ureana, Cecilia Crane

    2013-01-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers

  4. The Australian Commonwealth standard of measurement for absorbed radiation dose

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1990-06-01

    This report documents the absorbed dose standard for photon beams in the range from 1 to 25 MeV. Measurements of absorbed dose in graphite irradiated by a beam of cobalt-60 gamma rays from an Atomic Energy of Canada Limited (AECL) E1 Dorado 6 teletherapy unit are reported. The measurements were performed using a graphite calorimeter, which is the primary standard for absorbed dose. The measurements are used to calibrate a working standard ion chamber in terms of absorbed dose in graphite. Details of the methods, results and correction factors applied are given in Appendices. 13 refs., 6 tabs., 6 figs

  5. Computerized assessment of the measurement of individual doses

    International Nuclear Information System (INIS)

    Kiibus, A.

    1981-06-01

    The department for the measurements of individual doses makes regular dose controls by means of film badges for approximately 14000 individuals. The operation is facilitated by a Honeywell Bull Mini 6 Mod 43 computer. The computer language is COBOL applied to registering of in-data such as delivery of badges, film development, calibration, invoices, recording of individual doses and customers. The print-out consists of customers, badge codes, dosimeter lists, development specifications, dose statements, addresses, bills, dose statistics and the register of individuals. As a consequence of charges the activity is financially self-supporting. (G.B.)

  6. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    CERN Document Server

    Nakamura, T; Tonoike, K

    2003-01-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose b...

  7. Online radiation dose measurement system for ATLAS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Mikuz, M. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana (Slovenia); Bronner, J.; Hartet, J. [Physikalisches Institut, Universitat Freiburg, Hermann-Herder-Str. 3, Freiburg (Germany); Franz, S. [CERN, Geneva (Switzerland)

    2009-07-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO{sub 2} will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10{sup 9} n/cm{sup 2} for NIEL (non-ionizing energy loss) measurements, 10{sup 12} n/cm{sup 2} for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  8. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  9. Chromosomal aberrations and exposure doses during extracorporeal shock wave lithotripsy for renal ureteral stones

    International Nuclear Information System (INIS)

    Shao Songsheng; Feng Jialin; Weng Zhigen; Jiang Qingqi; Wang Guomin; Zhang Yuanfang; Zhang Renan

    1991-01-01

    The radiation dose and the chromosomal aberrations of peripheral lymphocytes were studied in 20 patients during ESWL. The dose was measured with calibrated thermoluminescent dosimeters. Primary results showed an average skin exposure 4.50 x 10 -3 C/kg per case. The dose level is smilar to that of the patients under-going routine fluoroscopic examination. Therefore, the radiation exposure with patients from the ESWL procedure should be considered acceptable. As chromosome changes, to reduce the radiation dose is important for the radiation cytogentics. The factors influencing exposure levels include stone characteristics and physician experience

  10. Peripheral airway impairment measured by oscillometry predicts loss of asthma control in children.

    Science.gov (United States)

    Shi, Yixin; Aledia, Anna S; Galant, Stanley P; George, Steven C

    2013-03-01

    We previously showed that impulse oscillometry (IOS) indices of peripheral airway function are associated with asthma control in children. However, little data exist on whether dysfunction in the peripheral airways can predict loss of asthma control. We sought to determine the utility of peripheral airway impairment, as measured by IOS, in predicting loss of asthma control in children. Fifty-four children (age, 7-17 years) with controlled asthma were enrolled in the study. Spirometric and IOS indices of airway function were obtained at baseline and at a follow-up visit 8 to 12 weeks later. Physicians who were blinded to the IOS measurements assessed asthma control (National Asthma Education and Prevention Program guidelines) on both visits and prescribed no medication change between visits. Thirty-eight (70%) patients maintained asthma control between 2 visits (group C-C), and 16 patients had asthma that became uncontrolled on the follow-up visit (group C-UC). There was no difference in baseline spirometric results between the C-C and C-UC groups, except for FEV1/forced vital capacity ratio (86% vs 82%, respectively; P IOS results, including resistance of the respiratory system at 5 Hz (R5; 6.4 vs 4.3 cm H2O · L(-1) · s), frequency dependence of resistance (difference of R5 and resistance of the respiratory system at 20 Hz [R5-20]; 2.0 vs 0.7 cm H2O · L(-1) · s), and reactance area (13.1 vs 4.1 cm H2O · L(-1)), of group C-UC were significantly higher than those of group C-C (P operating characteristic analysis showed baseline R5-20 and reactance area effectively predicted asthma control status at the follow-up visit (area under the curve, 0.91 and 0.90). Children with controlled asthma who have increased peripheral airway IOS indices are at risk of losing asthma control. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  11. KERMA-based radiation dose management system for real-time patient dose measurement

    Science.gov (United States)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  12. Measurement of peripheral electron temperature by electron cyclotron emission during the H-mode transition in JFT-2M tokamak

    International Nuclear Information System (INIS)

    Hoshino, Katsumichi; Yamamoto, Takumi; Kawashima, Hisato

    1987-01-01

    Time evolution and profile of peripheral electron temperature during the H-mode like transition in a tokamak plasma is measured using the second and third harmonic of electron cyclotron emission (ECE). The so called ''H-mode'' state which has good particle/energy confinement is characterized by sudden decrease in the spectral line intensity of deuterium molecule. Such a sudden decrease in the line intensity of D α with good energy confinement is found not only in divertor discharges, but also in limiter dischargs in JFT-2M tokamak. It is found by the measurement of ECE that the peripheral electron temperature suddenly increases in both of such phases. The relation between H-transition and the peripheral electron temperature or its profile is investigated. (author)

  13. A Retrospective Study Evaluating the Effect of Low Doses of Perineural Dexamethasone on Ropivacaine Brachial Plexus Peripheral Nerve Block Analgesic Duration.

    Science.gov (United States)

    Schnepper, Gregory D; Kightlinger, Benjamin I; Jiang, Yunyun; Wolf, Bethany J; Bolin, Eric D; Wilson, Sylvia H

    2017-09-23

    Examination of the effectiveness of perineural dexamethasone administered in very low and low doses on ropivacaine brachial plexus block duration. Retrospective evaluation of brachial plexus block duration in a large cohort of patients receiving peripheral nerve blocks with and without perineural dexamethasone in a prospectively collected quality assurance database. A single academic medical center. A total of 1,942 brachial plexus blocks placed over a 16-month period were reviewed. Demographics, nerve block location, and perineural dexamethasone utilization and dose were examined in relation to block duration. Perineural dexamethasone was examined as none (0 mg), very low dose (2 mg or less), and low dose (greater than 2 mg to 4 mg). Continuous catheter techniques, local anesthetics other than ropivacaine, and block locations with fewer than 15 subjects were excluded. Associations between block duration and predictors of interest were examined using multivariable regression models. A subgroup analysis of the impact of receiving dexamethasone on block duration within each block type was also conducted using a univariate linear regression approach. A total of 1,027 subjects were evaluated. More than 90% of brachial plexus blocks contained perineural dexamethasone (≤4 mg), with a median dose of 2 mg. Increased block duration was associated with receiving any dose of perineural dexamethasone (P block duration did not differ with very low- or low-dose perineural dexamethasone after controlling for other factors (P = 0.420). Perineural dexamethasone prolonged block duration compared with ropivacaine alone; however, duration was not greater with low-dose compared with very low-dose perineural dexamethasone. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Measurements and applications of dose indices in radiography

    International Nuclear Information System (INIS)

    Chen, T.R.; Tyan, Y.S.; Yang, J.J.; Shao, C.H.; Lin, J.Y.; Tung, C.J.

    2011-01-01

    Assessments of radiation dose and image quality are required in diagnostic radiography for quality assurance and optimization studies. In work currently being undertaken, dose indices were measured and image quality evaluated for a chest PA procedure. Thermoluminescent dosimeters of the GR-200 type were attached to the entrance and exit surfaces and placed at various depths of the PMMA phantom to measure the entrance surface dose, the exit surface dose, and the organ dose index. The effective dose was estimated from the entrance surface dose using PCXMC software. Two contrast-detail image plates, one with air holes for the low contrast objects and the other with gypsum holes for the high contrast objects, were used to obtain radiographic images. This image plate was placed at different depths from the entrance surface of the phantom to simulate objects at different positions in the body. Each image was evaluated by three independent radiologists to determine image quality. Analyses of radiation dose versus image quality were performed to determine the optimal technical factors such as, filtration and tube potential. It was found that an 11-cm thick PMMA phantom best simulated the patients. The fractional dose backscattered from this phantom was between 22% and 27% for kVp’s between 66 and 133. Optimization analyses showed that no extra filter was required. For low contrast objects, an optimal choice of tube potential was 120 kVp. For high contrast objects, a kVp as low as 77 kVp could be used, depending on the image quality requirement.

  15. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport

    International Nuclear Information System (INIS)

    Vukovic, B.; Radolic, V.; Lisjak, I.; Vekic, B.; Poje, M.; Planinic, J.

    2008-01-01

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or 10 B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 μSv/h and the TLD dosimeter registered the dose equivalent of 75 μSv or the average dose rate of 2.7 μSv/h; the neutron dosimeter gave the dose rate of 2.4 μSv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 μSv/h; the neutron dosimeter gave the dose rate of 2.5 μSv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data

  16. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B.; Radolic, V. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Lisjak, I. [Croatia Airlines, Zagreb (Croatia); Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Poje, M. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Planinic, J. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia)], E-mail: planinic@ffos.hr

    2008-02-15

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or {sup 10}B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 {mu}Sv/h and the TLD dosimeter registered the dose equivalent of 75 {mu}Sv or the average dose rate of 2.7 {mu}Sv/h; the neutron dosimeter gave the dose rate of 2.4 {mu}Sv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 {mu}Sv/h; the neutron dosimeter gave the dose rate of 2.5 {mu}Sv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data.

  17. Measurement of micronuclei and internal dose in mice demonstrates that 3-monochloropropane-1,2-diol (3-MCPD) has no genotoxic potency in vivo.

    Science.gov (United States)

    Aasa, Jenny; Törnqvist, Margareta; Abramsson-Zetterberg, Lilianne

    2017-11-01

    In this study 3-monochloropropane-1,2-diol (3-MCPD), a compound that appears as contaminant in refined cooking oils, has been studied with regard to genotoxicity in vivo (mice) with simultaneous measurement of internal dose using state-of-the-art methodologies. Genotoxicity (chromosomal aberrations) was measured by flow cytometry with dual lasers as the frequency of micronuclei in erythrocytes in peripheral blood from BalbC mice intraperitoneally exposed to 3-MCPD (0, 50, 75, 100, 125 mg/kg). The internal doses of 3-MCPD in the mice were calculated from N-(2,3-dihydroxypropyl)-valine adducts to hemoglobin (Hb), quantified at very low levels by high-resolution mass spectrometry. Convincing evidence for absence of genotoxic potency in correlation to measured internal doses in the mice was demonstrated, despite relatively high administered doses of 3-MCPD. The results are discussed in relation to another food contaminant that is formed as ester in parallel to 3-MCPD esters in oil processing, i.e. glycidol, which has been studied previously by us in a similar experimental setup. Glycidol has been shown to be genotoxic, and in addition to have ca. 1000 times higher rate of adduct formation compared to that observed for 3-MCPD. The conclusion is that at simultaneous exposure to 3-MCPD and glycidol the concern about genotoxicity would be glycidol. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Peripheral blood signatures of lead exposure.

    Directory of Open Access Journals (Sweden)

    Heather G LaBreche

    Full Text Available BACKGROUND: Current evidence indicates that even low-level lead (Pb exposure can have detrimental effects, especially in children. We tested the hypothesis that Pb exposure alters gene expression patterns in peripheral blood cells and that these changes reflect dose-specific alterations in the activity of particular pathways. METHODOLOGY/PRINCIPAL FINDING: Using Affymetrix Mouse Genome 430 2.0 arrays, we examined gene expression changes in the peripheral blood of female Balb/c mice following exposure to per os lead acetate trihydrate or plain drinking water for two weeks and after a two-week recovery period. Data sets were RMA-normalized and dose-specific signatures were generated using established methods of supervised classification and binary regression. Pathway activity was analyzed using the ScoreSignatures module from GenePattern. CONCLUSIONS/SIGNIFICANCE: The low-level Pb signature was 93% sensitive and 100% specific in classifying samples a leave-one-out crossvalidation. The high-level Pb signature demonstrated 100% sensitivity and specificity in the leave-one-out crossvalidation. These two signatures exhibited dose-specificity in their ability to predict Pb exposure and had little overlap in terms of constituent genes. The signatures also seemed to reflect current levels of Pb exposure rather than past exposure. Finally, the two doses showed differential activation of cellular pathways. Low-level Pb exposure increased activity of the interferon-gamma pathway, whereas high-level Pb exposure increased activity of the E2F1 pathway.

  19. Research on effects of ionizing radiation of human peripheral blood white cell adhesive molecules

    International Nuclear Information System (INIS)

    Li Haijun; Cheng Ying; Le Chen; Min Rui

    2008-01-01

    Objective: To investigate the links between expression and function of adhesive molecule on the surface of irradiated peripheral blood white cells. Methods: Heparinized human peripheral blood was exposed to γ rays with different dose. At the different post-radiation time adhesive molecule expression on cellular surface was determined by double fluorescence labeling antibodies which were against adhesive molecule and special mark of granulocyte or mononuclear cell respectively with flow cytometry, and cellular adhesive ability to different matrixes mediated by adhesive molecule was estimated by commercializing enzyme-linked immunosorbent assay kit and crystalviolet dying. Results: A decline pattern of CD11b on surface of mononuclear cells and CD29 on surface of granulocyte with irradiation dose increase was found. The changes of adhesive ability of mononuclear cells to substance of β1-integrin and collagen-I was well related with irradiation dose. Conclusion: Good relationship shown by the changes of adhesive molecule expression and adhesive ability mediated by the molecules on the surface of peripheral blood white cells with radiation dose was primary base of further research on indicting exposure dose by biomarker. (authors)

  20. Topiramate induced peripheral neuropathy: A case report and review of literature.

    Science.gov (United States)

    Hamed, Sherifa Ahmed

    2017-12-16

    Drug-induced peripheral neuropathy had been rarely reported as an adverse effect of some antiepileptic drugs (AEDs) at high cumulative doses or even within the therapeutic drug doses or levels. We describe clinical and diagnostic features of a patient with peripheral neuropathy as an adverse effect of chronic topiramate (TPM) therapy. A 37-year-old woman was presented for the control of active epilepsy (2010). She was resistant to some AEDs as mono- or combined therapies (carbamazepine, sodium valproate, levetiracetam, oxcarbazepine and lamotrigine). She has the diagnosis of frontal lobe epilepsy with secondary generalization and has a brother, sister and son with active epilepsies. She became seizure free on TPM (2013-2017) but is complaining of persistent distal lower extremities paresthesia in a stocking distribution. Neurological examination revealed presence of diminished Achilles tendon reflexes, stocking hypesthesia and delayed distal latencies, reduced conduction velocities and amplitudes of action potentials of posterior tibial and sural nerves, indicating demyelinating and axonal peripheral neuropathy of the lower extremities. After exclusion of the possible causes of peripheral neuropathy, chronic TPM therapy is suggested as the most probable cause of patient's neuropathy. This is the first case report of topiramate induced peripheral neuropathy in the literature.

  1. Verification of eye lens dose in IMRT by MOSFET measurement.

    Science.gov (United States)

    Wang, Xuetao; Li, Guangjun; Zhao, Jianling; Song, Ying; Xiao, Jianghong; Bai, Sen

    2018-04-17

    The eye lens is recognized as one of the most radiosensitive structures in the human body. The widespread use of intensity-modulated radiotherapy (IMRT) complicates dose verification and necessitates high standards of dose computation. The purpose of this work was to assess the computed dose accuracy of eye lens through measurements using a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimetry system. Sixteen clinical IMRT plans of head and neck patients were copied to an anthropomorphic head phantom. Measurements were performed using the MOSFET dosimetry system based on the head phantom. Two MOSFET detectors were imbedded in the eyes of the head phantom as the left and the right lens, covered by approximately 5-mm-thick paraffin wax. The measurement results were compared with the calculated values with a dose grid size of 1 mm. Sixteen IMRT plans were delivered, and 32 measured lens doses were obtained for analysis. The MOSFET dosimetry system can be used to verify the lens dose, and our measurements showed that the treatment planning system used in our clinic can provide adequate dose assessment in eye lenses. The average discrepancy between measurement and calculation was 6.7 ± 3.4%, and the largest discrepancy was 14.3%, which met the acceptability criterion set by the American Association of Physicists in Medicine Task Group 53 for external beam calculation for multileaf collimator-shaped fields in buildup regions. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  2. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  3. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  4. Cytogenetic analysis in peripheral blood lymphocytes after arteriography (exposure to X-rays and contrast medium)

    International Nuclear Information System (INIS)

    Hadjidekova, V.; Popova, L.; Hristova, R.; Hadjidekov, V.

    2006-01-01

    Full text: The purpose of our study is to investigate the cytogenetic effects in peripheral blood lymphocytes of 29 patients who had undergone diagnostic angiography. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13 and 68 years). Cytogenetic analysis was performed in peripheral lymphocytes before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03 - 0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency was used as biomarkers of genotoxicity. The estimated frequency of chromosomal aberrations and micronuclei in peripheral blood lymphocytes of patients after arteriography examination is significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations nearly double after examination and remained constant at 24h analysis. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase of the cytogenetic injury in peripheral blood lymphocytes

  5. Measurements of the dose due to cosmic rays in aircraft

    International Nuclear Information System (INIS)

    Vukovic, B.; Lisjak, I.; Radolic, V.; Vekic, B.; Planinic, J.

    2006-01-01

    When the primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The cosmic radiation dose aboard A320 and ATR 42 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; radon concentration in the atmosphere was measured with the Alpha Guard radon detector. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed by the flights Zagreb-Paris-Buenos Aires and reversely, when one measured cosmic radiation dose; for 26.7 h of flight, the TLD dosimeter registered the total dose of 75 μSv and the average dose rate was 2.7 μSv/h. In the same month, February 2005, a traveling to Japan (24 h flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 μSv/h

  6. Measurements of the dose due to cosmic rays in aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Lisjak, I. [Croatia Airlines, Zagreb (Croatia); Radolic, V. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Planinic, J. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia)]. E-mail: planinic@ffos.hr

    2006-06-15

    When the primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The cosmic radiation dose aboard A320 and ATR 42 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; radon concentration in the atmosphere was measured with the Alpha Guard radon detector. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed by the flights Zagreb-Paris-Buenos Aires and reversely, when one measured cosmic radiation dose; for 26.7 h of flight, the TLD dosimeter registered the total dose of 75 {mu}Sv and the average dose rate was 2.7 {mu}Sv/h. In the same month, February 2005, a traveling to Japan (24 h flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 {mu}Sv/h.

  7. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  8. Measurement of absorbed dose with a bone-equivalent extrapolation chamber

    International Nuclear Information System (INIS)

    DeBlois, Francois; Abdel-Rahman, Wamied; Seuntjens, Jan P.; Podgorsak, Ervin B.

    2002-01-01

    A hybrid phantom-embedded extrapolation chamber (PEEC) made of Solid Water trade mark sign and bone-equivalent material was used for determining absorbed dose in a bone-equivalent phantom irradiated with clinical radiation beams (cobalt-60 gamma rays; 6 and 18 MV x rays; and 9 and 15 MeV electrons). The dose was determined with the Spencer-Attix cavity theory, using ionization gradient measurements and an indirect determination of the chamber air-mass through measurements of chamber capacitance. The collected charge was corrected for ionic recombination and diffusion in the chamber air volume following the standard two-voltage technique. Due to the hybrid chamber design, correction factors accounting for scatter deficit and electrode composition were determined and applied in the dose equation to obtain absorbed dose in bone for the equivalent homogeneous bone phantom. Correction factors for graphite electrodes were calculated with Monte Carlo techniques and the calculated results were verified through relative air cavity dose measurements for three different polarizing electrode materials: graphite, steel, and brass in conjunction with a graphite collecting electrode. Scatter deficit, due mainly to loss of lateral scatter in the hybrid chamber, reduces the dose to the air cavity in the hybrid PEEC in comparison with full bone PEEC by 0.7% to ∼2% depending on beam quality and energy. In megavoltage photon and electron beams, graphite electrodes do not affect the dose measurement in the Solid Water trade mark sign PEEC but decrease the cavity dose by up to 5% in the bone-equivalent PEEC even for very thin graphite electrodes (<0.0025 cm). In conjunction with appropriate correction factors determined with Monte Carlo techniques, the uncalibrated hybrid PEEC can be used for measuring absorbed dose in bone material to within 2% for high-energy photon and electron beams

  9. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    International Nuclear Information System (INIS)

    Lamb, J; Agazaryan, N; Cao, M; Low, D; Thomas, D; Yang, Y

    2015-01-01

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc

  10. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takemi; Tonoike, Kotaro; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The authors participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the authors derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose by the evaluation formula to the measured value by the alanine dosimeter was 0.94 and the formula agreed within 6%. From examination of this TRACY, we can conclude that the value reported to OECD/NEA has equivalent accuracy. (author)

  11. Measurement of annual dose on porcelain using surface TLD method

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2001-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of measurement of annual dose using ultrathin (CaSO 4 :Tm) dosage layer on porcelain was studied. The TLD was placed on the part of porcelain without glaze. A comparison of measurement of annual dose for surface TLD, inside TLD and alpha counting on porcelain was made. The results show that this technique is suitable for measuring annual dose and improving accuracy of TL authentication test for both porcelain and pottery

  12. Influence of peripheral blood hemoglobin concentration on the result of radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    He Beiwa; Zhang Guofen; Zhao Yutian; Wang Zhenwu; Xu Min; Hu Yulin

    2002-01-01

    Objective: To determine the influence of peripheral blood hemoglobin concentration on the radiotherapy result of nasopharyngeal carcinoma (NPC). Methods: From January 1989 to December 1998, 304 patients with pathologically confirmed NPC received radical radiation. There were 209 males and 95 females. The ages ranged from 16 to 77 years with a median of 42. All patients were irradiated by 60 Co or 6 MV external beam with a total dose of 64 - 76 Gy for the primary tumor and 46 - 77 Gy for the cervical lymph nodes. The peripheral blood hemoglobin concentration for all patients was measured before, during and after radiotherapy. These patients were divided into three groups according to the peripheral blood hemoglobin concentration before radiotherapy: anemia ( 160 g/L), and into two groups according to the change in the peripheral blood hemoglobin concentration during radiotherapy as increased and decreased groups. Results: All patients were followed with a follow-up rate of 90.5%. The peripheral blood hemoglobin concentration had a significant effect on the survival of NPC patients. Its decrease or increase during radiotherapy affected the survival and local control rates of NPC patients. Conclusions: The change of peripheral hemoglobin concentration affecting the oxygen content in the blood, can influence the local control and survival rates of NPC patients. Increase results in higher survival

  13. Non-invasive assessment of peripheral arterial disease: Automated ankle brachial index measurement and pulse volume analysis compared to duplex scan.

    Science.gov (United States)

    Lewis, Jane Ea; Williams, Paul; Davies, Jane H

    2016-01-01

    This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index 50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals.

  14. TLD array for precise dose measurements in stereotactic radiation techniques

    International Nuclear Information System (INIS)

    Ertl, A.; Kitz, K.; Griffitt, W.; Hartl, R.F.E.; Zehetmayer, M.

    1996-01-01

    We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy. (author)

  15. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  16. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  17. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  18. Individual radiation therapy patient whole-body phantoms for peripheral dose evaluations: method and specific software

    International Nuclear Information System (INIS)

    Alziar, I; Vicente, C; Giordana, G; Ben-Harrath, O; De Vathaire, F; Diallo, I; Bonniaud, G; Couanet, D; Chavaudra, J; Lefkopoulos, D; Ruaud, J B; Diaz, J C; Grandjean, P; Kafrouni, H

    2009-01-01

    This study presents a method aimed at creating radiotherapy (RT) patient-adjustable whole-body phantoms to permit retrospective and prospective peripheral dose evaluations for enhanced patient radioprotection. Our strategy involves virtual whole-body patient models (WBPM) in different RT treatment positions for both genders and for different age groups. It includes a software tool designed to match the anatomy of the phantoms with the anatomy of the actual patients, based on the quality of patient data available. The procedure for adjusting a WBPM to patient morphology includes typical dimensions available in basic auxological tables for the French population. Adjustment is semi-automatic. Because of the complexity of the human anatomy, skilled personnel are required to validate changes made in the phantom anatomy. This research is part of a global project aimed at proposing appropriate methods and software tools capable of reconstituting the anatomy and dose evaluations in the entire body of RT patients in an adapted treatment planning system (TPS). The graphic user interface is that of a TPS adapted to obtain a comfortable working process. Such WBPM have been used to supplement patient therapy planning images, usually restricted to regions involved in treatment. Here we report, as an example, the case of a patient treated for prostate cancer whose therapy planning images were complemented by an anatomy model. Although present results are preliminary and our research is ongoing, they appear encouraging, since such patient-adjusted phantoms are crucial in the optimization of radiation protection of patients and for follow-up studies. (note)

  19. Individual radiation therapy patient whole-body phantoms for peripheral dose evaluations: method and specific software.

    Science.gov (United States)

    Alziar, I; Bonniaud, G; Couanet, D; Ruaud, J B; Vicente, C; Giordana, G; Ben-Harrath, O; Diaz, J C; Grandjean, P; Kafrouni, H; Chavaudra, J; Lefkopoulos, D; de Vathaire, F; Diallo, I

    2009-09-07

    This study presents a method aimed at creating radiotherapy (RT) patient-adjustable whole-body phantoms to permit retrospective and prospective peripheral dose evaluations for enhanced patient radioprotection. Our strategy involves virtual whole-body patient models (WBPM) in different RT treatment positions for both genders and for different age groups. It includes a software tool designed to match the anatomy of the phantoms with the anatomy of the actual patients, based on the quality of patient data available. The procedure for adjusting a WBPM to patient morphology includes typical dimensions available in basic auxological tables for the French population. Adjustment is semi-automatic. Because of the complexity of the human anatomy, skilled personnel are required to validate changes made in the phantom anatomy. This research is part of a global project aimed at proposing appropriate methods and software tools capable of reconstituting the anatomy and dose evaluations in the entire body of RT patients in an adapted treatment planning system (TPS). The graphic user interface is that of a TPS adapted to obtain a comfortable working process. Such WBPM have been used to supplement patient therapy planning images, usually restricted to regions involved in treatment. Here we report, as an example, the case of a patient treated for prostate cancer whose therapy planning images were complemented by an anatomy model. Although present results are preliminary and our research is ongoing, they appear encouraging, since such patient-adjusted phantoms are crucial in the optimization of radiation protection of patients and for follow-up studies.

  20. Comparison of dose measurements in water versus in air for therapy

    International Nuclear Information System (INIS)

    Nasukha

    1987-01-01

    Comparison of dose measurements in water versus in air for therapy. Dose measurements in water and in the air had been done by teletherapy unit Co-60 Picker Model V 4m/60 with Farmer dosimeter. The result of inverse square law, TAR, PDD, and PSF compared to BJR No. 17 produced a difference of more than 4,65% with SSD 80 cm. Doses in water calculated from the result of dose measurement in air using BJR tables given, was compared with direct dose measurement in water. Values of 0,9850 to 1,0302 were obtained if using inverse square law, PDD and PSF formula. Using inverse square law and TAR, values of 0,9474 to 1,0197 were obtained for 4 depths and 5 field sizes. Measurements done in 5 cm depth and 10 cm x 10 cm field size using both methods, were still good. (author). 7 figs, 8 refs

  1. Cosmic-ray contribution in measurement of environmental gamma-ray dose

    International Nuclear Information System (INIS)

    Nagaoka, Kazunori; Honda, Kouichirou; Miyano, Keiji

    1996-01-01

    Nowadays several kinds of dosimeters are being used for environmental gamma-ray monitoring. However the results measured by those instruments are not always in good agreement. It may be caused from the different characteristics of dosimeters. In particular the different responses of the instruments to cosmic-rays give significant influence on the results. Environmental radiation measurements at various altitudes on Mt. Fuji were carried out using a scintillation spectrometer with 3''φ spherical NaI(Tl), a pressurized ionization chamber (PIC), an air-equivalent ionization chamber (IC), thermoluminescence dosimeters (TLD), radiophotoluminescence glass dosimeters (RPLD) and NaI(Tl) scintillation survey meters so that the response characteristics of these instruments to cosmic-rays could be clarified. Cosmic-ray contributions for all instruments were correlated with counting rate over 3 MeV by the spectrometer. Each contribution can be estimated by measurement of the counting rate. Conversion factors (nGy/h/cpm) for IC, PIC, TLD, RPLD and NaI survey meters (TCS166 and TCS121C) were 0.33, 0.32, 0.25, 0.24, 0.06 and -0.01, respectively. Self-doses of these instruments were estimated by measurements at Nokogiriyama facilities of the Institute for Cosmic Ray Research, University of Tokyo. Self-doses for TLD and RPLD were approximately 6 nGy/h. The self dose effect should be taken into consideration in environmental dose measurements. These data are expected to be useful in estimating the cosmic-ray contribution and self-dose in the measurement of environmental gamma-ray dose. (author)

  2. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  3. Comparison of measured and calculated doses for narrow MLC defined fields

    International Nuclear Information System (INIS)

    Lydon, J.; Rozenfeld, A.; Lerch, M.

    2002-01-01

    Full text: The introduction of Intensity Modulated Radiotherapy (IMRT) has led to the use of narrow fields in the delivery of radiation doses to patients. Such fields are not well characterized by calculation methods commonly used in radiotherapy treatment planning systems. The accuracy of the dose calculation algorithm must therefore be investigated prior to clinical use. This study looked at symmetrical and asymmetrical 0.1 to 3cm wide fields delivered with a Varian CL2100C 6MV photon beam. Measured doses were compared to doses calculated using Pinnacle, the ADAC radiotherapy treatment planning system. Two high resolution methods of measuring dose were used. A MOSFET detector in a water phantom and radiographic film in a solid water phantom with spatial resolutions of 10 and 89μm respectively. Dose calculations were performed using the collapsed cone convolution algorithm in Pinnacle with a 0.1cm dose calculation grid in the MLC direction. The effect of Pinnacle not taking into account the rounded leaf ends was simulated by offsetting the leaves by 0.1cm in the dose calculation. Agreement between measurement and calculation is good for fields of 1cm and wider. However, fields of less than 1cm width can show a significant difference between measurement and calculation

  4. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  5. Prototype development or multi-cavity ion chamber for depth dose measurement

    International Nuclear Information System (INIS)

    Nayak, M.K.; Sahu, T.K.; Haridas, G.; Bandyopadhyay, Tapas; Tripathi, R.M.; Nandedkar, R.V.

    2016-01-01

    In high energy electron accelerators, when the electrons interact with vacuum chamber or surrounding structural material, Bremsstrahlung x-rays are produced. It is having a broad spectrum extending up to the electron energies. Dose measured as a function of depth due to electromagnetic cascade will give rise to depth dose curve. To measure the online depth dose profile in an absorber medium, when high energy electron or Bremsstrahlung is incident, a prototype Multi-Cavity Ion Chamber (MCIC) detector is developed. The paper describes the design and development of the MCIC for measurement of depth dose profile

  6. Impact of a Low CD34+ Cell Dose on Allogeneic Peripheral Blood Stem Cell Transplantation.

    Science.gov (United States)

    Yamamoto, Chihiro; Ogawa, Hiroyasu; Fukuda, Takahiro; Igarashi, Aiko; Okumura, Hirokazu; Uchida, Naoyuki; Hidaka, Michihiro; Nakamae, Hirohisa; Matsuoka, Ken-Ichi; Eto, Tetsuya; Ichinohe, Tatsuo; Atsuta, Yoshiko; Kanda, Yoshinobu

    2018-04-01

    Although the CD34 + cell dose in allogeneic peripheral blood stem cell transplantation (PBSCT) is considered to be associated with transplantation outcomes, a lower acceptable threshold has not been defined. We retrospectively analyzed 2919 adult patients with hematologic malignancies who underwent related PBSCT in Japan between 2001 and 2014. According to the number of CD34 + cells in the graft, we categorized 2494 patients in the standard group (2 to 5 × 10 6 cells/kg), 377 patient in the low group (1 to 2 × 10 6 cells/kg), and 48 patients in the very low group (<1 × 10 6 cells/kg). Compared with the standard group, the low and very low groups showed delayed neutrophil recovery (93.8%, 89.5%, and 78.3%, respectively at day +28; P < .001) and platelet recovery (69.3%, 53.0%, and 45.5%, respectively at day +28; P < .001). The 2-year overall survival (OS) in the 3 groups was 45.5%, 45.3%, and 29.8%, respectively, with inferior survival in the very low group. However, a higher percentage of high-risk patients may account for the inferior survival in the very low group, and no significant difference in OS was found in a multivariate analysis. There were no differences in relapse, nonrelapse mortality, or the development of graft-versus-host disease among the 3 groups. In conclusion, allogeneic PBSCT with low CD34 + cell doses of 1 to 2 × 10 6 cells/kg gives acceptable results, whereas further investigations are needed to evaluate the effects of lower doses of <1 × 10 6 cells/kg owing to the smaller number and the higher percentage of patients with adverse prognostic factors in this cohort. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  7. Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements

    International Nuclear Information System (INIS)

    Aragno, D.; Fattibene, P.; Onori, S.

    2000-01-01

    Electron paramagnetic resonance dosimetry of tooth enamel is now established as a suitable method for individual dose reconstruction following radiation accidents. The accuracy of the method is limited by some confounding factors, among which is the dose received due to medical x-ray irradiation. In the present paper the EPR response of tooth enamel to endoral examination was experimentally evaluated using an anthropomorphic phantom. The dose to enamel for a single exposure of a typical dental examination performed with a new x-ray generation unit working at 65 kVp gave rise to a CO 2 -signal of intensity similar to that induced by a dose of about 2 mGy of 60 Co. EPR measurements were performed on the entire tooth with no attempt to separate buccal and lingual components. Also the dose to enamel for an orthopantomography exam was estimated. It was derived from TLD measurements as equivalent to 0.2 mGy of 60 Co. In view of application to risk assessment analysis, in the present work the value for the ratio of the reference dose at the phantom surface measured with TLD to the dose at the tooth measured with EPR was determined. (author)

  8. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k......Rad. The precision limits of the measurement of dose were found to be ±4%. The procedure was simple and the holographic equipment stable and compact, thus allowing experimentation under routine laboratory conditions and limited space....

  9. Effect of flavonol and its dimethoxy derivatives on paclitaxel-induced peripheral neuropathy in mice.

    Science.gov (United States)

    Sayeli, Vijaykumar; Nadipelly, Jagan; Kadhirvelu, Parimala; Cheriyan, Binoy Varghese; Shanmugasundaram, Jaikumar; Subramanian, Viswanathan

    2018-04-13

    Peripheral neuropathy is the dose limiting side effect of many anticancer drugs. Flavonoids exhibit good antinociceptive effect in animal models. Their efficacy against different types of nociception has been documented. The present study investigated the effect of flavonol (3-hydroxy flavone), 3',4'-dimethoxy flavonol, 6,3'-dimethoxy flavonol, 7,2'-dimethoxy flavonol and 7,3'-dimethoxy flavonol against paclitaxel-induced peripheral neuropathy in mice. A single dose of paclitaxel (10 mg/kg, i.p.) was administered to induce peripheral neuropathy in mice and the manifestations of peripheral neuropathy such as tactile allodynia, cold allodynia and thermal hyperalgesia were assessed 24 h later by employing Von Frey hair aesthesiometer test, acetone bubble test and hot water tail immersion test, respectively. The test compounds were prepared as a suspension in 0.5% carboxymethyl cellulose and were administered s.c. in various doses (25, 50, 100 and 200 mg/kg). The above behavioral responses were assessed prior to and 30 min after drug treatment. In addition, the effect of test compounds on proinflammatory cytokines like tumor necrosis factor-alpha (TNF-α), interleukin-1-beta (IL-1β) and free radicals was investigated by using suitable in vitro assays. A dose-dependent attenuation of tactile allodynia, cold allodynia and thermal hyperalgesia was evidenced in mice treated with flavonol derivatives. The test compounds inhibited TNF-α, IL-1β and free radicals in a concentration-dependent manner. These results revealed that flavonol and its dimethoxy derivatives ameliorated the manifestations of paclitaxel-induced peripheral neuropathy in mice. The inhibition of proinflammatory cytokines and free radicals could contribute to this beneficial effect.

  10. Oblique incidence of electron beams - comparisons between calculated and measured dose distributions

    International Nuclear Information System (INIS)

    Karcher, J.; Paulsen, F.; Christ, G.

    2005-01-01

    Clinical applications of high-energy electron beams, for example for the irradiation of internal mammary lymph nodes, can lead to oblique incidence of the beams. It is well known that oblique incidence of electron beams can alter the depth dose distribution as well as the specific dose per monitor unit. The dose per monitor unit is the absorbed dose in a point of interest of a beam, which is reached with a specific dose monitor value (DIN 6814-8[5]). Dose distribution and dose per monitor unit at oblique incidence were measured with a small-volume thimble chamber in a water phantom, and compared to both normal incidence and calculations of the Helax TMS 6.1 treatment planning system. At 4 MeV and 60 degrees, the maximum measured dose per monitor unit at oblique incidence was decreased up to 11%, whereas at 18MeV and 60 degrees this was increased up to 15% compared to normal incidence. Comparisons of measured and calculated dose distributions showed that the predicted dose at shallow depths is usually higher than the measured one, whereas it is smaller at depths beyond the depth of maximum dose. On the basis of the results of these comparisons, normalization depths and correction factors for the dose monitor value were suggested to correct the calculations of the dose per monitor unit. (orig.)

  11. Measures of chronic kidney disease and risk of incident peripheral artery disease: a collaborative meta-analysis of individual participant data.

    Science.gov (United States)

    Matsushita, Kunihiro; Ballew, Shoshana H; Coresh, Josef; Arima, Hisatomi; Ärnlöv, Johan; Cirillo, Massimo; Ebert, Natalie; Hiramoto, Jade S; Kimm, Heejin; Shlipak, Michael G; Visseren, Frank L J; Gansevoort, Ron T; Kovesdy, Csaba P; Shalev, Varda; Woodward, Mark; Kronenberg, Florian

    2017-09-01

    Some evidence suggests that chronic kidney disease is a risk factor for lower-extremity peripheral artery disease. We aimed to quantify the independent and joint associations of two measures of chronic kidney disease (estimated glomerular filtration rate [eGFR] and albuminuria) with the incidence of peripheral artery disease. In this collaborative meta-analysis of international cohorts included in the Chronic Kidney Disease Prognosis Consortium (baseline measurements obtained between 1972 and 2014) with baseline measurements of eGFR and albuminuria, at least 1000 participants (this criterion not applied to cohorts exclusively enrolling patients with chronic kidney disease), and at least 50 peripheral artery disease events, we analysed adult participants without peripheral artery disease at baseline at the individual patient level with Cox proportional hazards models to quantify associations of creatinine-based eGFR, urine albumin-to-creatinine ratio (ACR), and dipstick proteinuria with the incidence of peripheral artery disease (including hospitalisation with a diagnosis of peripheral artery disease, intermittent claudication, leg revascularisation, and leg amputation). We assessed discrimination improvement through c-statistics. We analysed 817 084 individuals without a history of peripheral artery disease at baseline from 21 cohorts. 18 261 cases of peripheral artery disease were recorded during follow-up across cohorts (median follow-up was 7·4 years [IQR 5·7-8·9], range 2·0-15·8 years across cohorts). Both chronic kidney disease measures were independently associated with the incidence of peripheral artery disease. Compared with an eGFR of 95 mL/min per 1·73 m 2 , adjusted hazard ratios (HRs) for incident study-specific peripheral artery disease was 1·22 (95% CI 1·14-1·30) at an eGFR of 45 mL/min per 1·73 m 2 and 2·06 (1·70-2·48) at an eGFR of 15 mL/min per 1·73 m 2 . Compared with an ACR of 5 mg/g, the adjusted HR for incident study

  12. Effects on peripheral and central blood pressure of cocoa with natural or high-dose theobromine: a randomized, double-blind crossover trial.

    Science.gov (United States)

    van den Bogaard, Bas; Draijer, Richard; Westerhof, Berend E; van den Meiracker, Anton H; van Montfrans, Gert A; van den Born, Bert-Jan H

    2010-11-01

    Flavanol-rich cocoa products have been reported to lower blood pressure. It has been suggested that theobromine is partially responsible for this effect. We tested whether consumption of flavanol-rich cocoa drinks with natural or added theobromine could lower peripheral and central blood pressure. In a double-blind, placebo-controlled 3-period crossover trial we assigned 42 healthy individuals (age 62±4.5 years; 32 men) with office blood pressure of 130 to 159 mm Hg/85 to 99 mm Hg and low added cardiovascular risk to a random treatment sequence of dairy drinks containing placebo, flavanol-rich cocoa with natural dose consisting of 106 mg of theobromine, or theobromine-enriched flavanol-rich cocoa with 979 mg of theobromine. Treatment duration was 3 weeks with a 2-week washout. The primary outcome was the difference in 24-hour ambulatory systolic blood pressure between placebo and active treatment after 3 weeks. The difference in central systolic blood pressure between placebo and active treatment was a secondary outcome. Treatment with theobromine-enriched cocoa resulted in a mean±SE of 3.2±1.1 mm Hg higher 24-hour ambulatory systolic blood pressure compared with placebo (Ptheobromine-enriched cocoa, laboratory peripheral systolic blood pressure was not different from placebo, whereas central systolic blood pressure was 4.3±1.4 mm Hg lower (P=0.001). Natural dose theobromine cocoa did not significantly change either 24-hour ambulatory or central systolic blood pressure compared with placebo. In conclusion, theobromine-enriched cocoa significantly increased 24-hour ambulatory systolic blood pressure while lowering central systolic blood pressure.

  13. Technical specification of the NRPB thermoluminescent dosemeter used for the measurement of body dose and skin dose

    CERN Document Server

    Shaw, K B

    1977-01-01

    This report specifies the NRPB thermoluminescent dosemeter used for the measurement of radiation dose in tissue at a depth of 700 mg cm sup - sup 2 (body dose) and at a depth of 5-10 mg cm sup - sup 2 (skin dose).

  14. Measurement and evaluation of internal dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Chang, S. Y.; Lee, J. I.; Song, M. Y.

    2006-01-01

    This report describes the contents and results for implementation of internal radiation monitoring programme, measurement of uranium present in lung by lung counter and assessment of committed effective dose for radiation workers of the KNFC. The aim of radiation protection was achieved by implementing this activity

  15. Rapid Measurement of Neutron Dose Rate for Transport Index

    International Nuclear Information System (INIS)

    Morris, R.L.

    2000-01-01

    A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 μSv per hour (20 μrem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNPtrademark are reported for materials typical of those being shipped

  16. Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels

    International Nuclear Information System (INIS)

    Antic, V.; Ciraj-Bjelac, O.; Rehani, M.; Aleksandric, S.; Arandjic, D.; Ostojic, M.

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy -1 cm -2 for the first operator, 0.33 mSv Gy -1 cm -2 for the second operator/nurse and 0.16 mSv Gy -1 cm -2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. (authors)

  17. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  18. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  19. Dose Rate of Environmental Gamma Radiation in Java Island

    International Nuclear Information System (INIS)

    Gatot Suhariyono; Buchori; Dadong Iskandar

    2007-01-01

    The dose rate Monitoring of environmental gamma radiation at some locations in Java Island in the year 2005 / 2006 has been carried out. The dose rate measurement of gamma radiation is carried out by using the peripheral of Portable Gamma of Ray Spectrometer with detector of NaI(Tl), Merck Exploranium, Model GR-130- MINISPEC, while to determine its geographic position is used by the GPS (Global Positioning System), made in German corporation of GPS III Plus type. The division of measurement region was conducted by dividing Java Island become 66 parts with same distance, except in Jepara area that will built PLTN (Nuclear Energy Power), distance between measurement points is more closed. The results of dose rate measurement are in 66 locations in Java Island the range of (19.24 ± 4.05) nSv/hour until (150.78 ± 12.26) nSv/hour with mean (51.93 ± 36.53) nSv/h. The lowest dose rate was in location of Garut, while highest dose rate was in Ujung Lemah Abang, Jepara location. The data can be used for base line data of dose rate of environmental gamma radiation in Indonesia, specially in Java Island. The mean level of gamma radiation in Java monitoring area (0.46 mSv / year) was still lower than worldwide average effective dose rate of terrestrial gamma rays 0.5 mSv / year (report of UNSCEAR, 2000). (author)

  20. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  1. A study of the indices of the peripheral blood of women, professionally exposed to low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Bliznakov, V.; Mikhajlov, M.A.; Serafimov, A.; Nikolov, A.

    1979-01-01

    The peripheral blood content in women, which, due to their occupation are exposed to low dose ionizing radiation effect, has been investigated. One hundred and ten women from 20 to 50 years of age and occupation service in a sphere of ionizing radiation from 6 months to 4 years (an average length of 2,5 years) were examined. The unequal external gamma irradiation was the fundamental factor of the radiation effect under conditions of occupational media. The mean annual dose did never exceed the maximum permissible limits. As control, a group of 106 clinically healthy women of the same age and working in the industry but not exposed to radiation effect, was formed. Hemoglobin quantity, erythrocytes and leukocytes number, differential count of leukocytes and thrombocytes number were analyzed. Not any statistically significant differences (p > 0,05) between the mean values of the studied parameters of the control group and this one of women exposed to occupational irradiation were observed. This analysis of the hematological parameters represents the first stage of the already undertaken dynamic examination of the health status of a new and relatively stable contingent of occupationally irradiated persons. (A.B.)

  2. TU-F-CAMPUS-T-04: An Evaluation of Out-Of-Field Doses for Electron Beams From Modern Varian and Elekta Linear Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, C; Nitsch, P; Kudchadker, R; Howell, R; Kry, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Accurately determining out-of-field doses when using electron beam radiotherapy is of importance when treating pregnant patients or patients with implanted electronic devices. Scattered doses outside of the applicator field in electron beams have not been broadly investigated, especially since manufacturers have taken different approaches in applicator designs. Methods: In this study, doses outside of the applicator field were measured for electron beams produced by a 10×10 applicator on two Varian 21iXs operating at 6, 9, 12, 16, and 20 MeV, a Varian TrueBeam operating at 6, 9, 12, 16, and 20 MeV, and an Elekta Versa HD operating at 6, 9, 12 and 15 MeV. Peripheral dose profiles and percent depth doses were measured in a Wellhofer water phantom at 100 cm SSD with a Farmer ion chamber. Doses were compared to peripheral photon doses from AAPM’s Task Group #36 report. Results: Doses were highest for the highest electron energies. Doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. Substantial dose differences were observed between different accelerators; the Elekta accelerator had much higher doses than any Varian unit examined. Surprisingly, doses were often similar to, and could be much higher than, doses from photon therapy. Doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Conclusion: The results of this study indicate that proper shielding may be very important when utilizing electron beams, particularly on a Versa HD, while treating pregnant patients or those with implanted electronic devices. Applying a water equivalent bolus of Emax(MeV)/4 thickness (cm) on the patient would reduce fetal dose drastically for all clinical energies and is a practical solution to manage the potentially high peripheral doses seen from modern electron beams. Funding from NIH Grant number: #CA180803.

  3. Measurements of gamma-ray dose from a moderated 252Cf source

    International Nuclear Information System (INIS)

    McDonald, J.C.; Griffith, R.V.; Plato, P.; Miklos, J.

    1983-06-01

    The gamma-ray dose fraction from a moderated 252 Cf source was determined by using three types of dosimetry systems. Measurements were carried out in air at a distance of 35 cm from the surface of the moderating sphere (50 cm from the source which is at the center of the sphere) to the geometrical center of each detector. The moderating sphere is 0.8-mm-thick stainless steel shell filled with D 2 O and covered with 0.5 mm of cadmium. Measurements were also carried out with instruments and dosimeters positioned at the surface of a 40 cm x 40 cm x 15 cm plexiglass irradiation phantom whose front surface was also 35 cm from the surface of the moderating sphere. A-150 tissue-equivalent (TE) plastic ionization chambers and a TE proportional counter (TEPC) were used to measure tissue dose, from which the neutron dose equivalent was computed. The ratio of gamma-ray dose to the neutron dose equivalent was determined by using a relatively neutron-insensitive Geiger-Mueller (GM) counter and thermoluminescent dosimeters (TLD). In addition, the event-size spectrum measured by the TEPC was also used to compute the gamma-ray dose fraction. The average value for the ratio of gamma-ray dose to neutron dose equivalent was found to be 0.18 with an uncertainty of about +-18%

  4. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A large number of portable survey instruments employing G.M., ionization chamber, and scintillation detectors used for gamma measurements are also used for monitoring in beta fields by using removable shields to separate the beta and gamma components of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. Appropriate calibrations and correction factors can be used to reduce the errors in beta measurements to a tolerable level

  5. Target and peripheral dose from radiation sector motions accompanying couch repositioning of patient coordinates with the Gamma Knife® Perfexion™

    International Nuclear Information System (INIS)

    Tran, Tuan-Anh; Wu, Vincent; Malhotra, Harish; Steinman, James P.; Prasad, Dheerendra; Podgorsak, Matthew B.

    2011-01-01

    The GammaPlan ™ treatment planning system (TPS) does not fully account for shutter dose when multiple shots are required to deliver a patient’s treatment. The unaccounted exposures to the target site and its periphery are measured in this study. The collected data are compared to a similar effect from the Gamma Knife ® model 4C. A stereotactic head frame was attached to a Leksell ® 16 cm diameter spherical phantom; using a fiducial-box, CT images of the phantom were acquired and registered in the TPS. Measurements give the relationship of measured dose to the number of repositions with the patient positioning system (PPS) and to the collimator size. An absorbed dose of 10 Gy to the 50% isodose line was prescribed to the target site and all measurements were acquired with an ionization chamber. Measured dose increases with frequency of repositioning and with collimator size. As the radiation sectors transition between the beam on and beam off states, the target receives more shutter dose than the periphery. Shutter doses of 3.53±0.04 and 1.59±0.04 cGy/reposition to the target site are observed for the 16 and 8 mm collimators, respectively. The target periphery receives additional dose that varies depending on its position relative to the target. The radiation sector motions for the Gamma Knife ® Perfexion ™ result in an additional dose due to the shutter effect. The magnitude of this exposure is comparable to that measured for the model 4C

  6. Fluctuations in Brain Temperature Induced by Lypopolysaccharides: Central and Peripheral Contributions

    Directory of Open Access Journals (Sweden)

    Jeremy S. Tang

    2010-01-01

    Full Text Available In this study, we examined changes in central (anterior-preoptic hypothalamus and peripheral (temporal muscle and facial skin temperatures in freely moving rats following intravenous administration of bacterial lipopolysaccharides (LPS at low doses (1 and 10 μg/kg at thermoneutral conditions (28˚C. Recordings were made with high temporal resolution (5-s bin and the effects of LPS were compared with those induced by a tail-pinch, a standard arousing somato-sensory stimulus. At each dose, LPS moderately elevated brain, muscle and skin temperatures. In contrast to rapid, monophasic and relatively short hyperthermic responses induced by a tail-pinch, LPS-induced increases in brain and muscle temperatures occurred with ~40 min onset latencies, showed three not clearly defined phases, were slightly larger with the 10 μm/kg dose and maintained for the entire 4-hour post-injection recording duration. Based on dynamics of brain-muscle and skin-muscle temperature differentials, it appears that the hyperthermic response induced by LPS at the lowest dose originates from enhanced peripheral heat production, with no evidence of brain metabolic activation and skin vasoconstriction. While peripheral heat production also appears to determine the first phase of brain and body temperature elevation with LPS at 10 μg/kg, a further prolonged increase in brain-muscle differentials (onset at ~100 min suggests metabolic brain activation as a factor contributing to brain and body hyperthermia. At this dose, skin temperature increase was weaker than in temporal muscle, suggesting vasoconstriction as another contributor to brain/ body hyperthermia. Therefore, although both LPS at low doses and salient sensory stimuli moderately increase brain and body temperatures, these hyperthermic responses have important qualitative differences, reflecting unique underlying mechanisms.

  7. Fluctuations in brain temperature induced by lipopolysaccharides: central and peripheral contributions.

    Science.gov (United States)

    Tang, Jeremy S; Kiyatkin, Eugene A

    2010-01-01

    In this study, we examined changes in central (anterior-preoptic hypothalamus) and peripheral (temporal muscle and facial skin) temperatures in freely moving rats following intravenous administration of bacterial lipopolysaccharides (LPS) at low doses (1 and 10 μg/kg) at thermoneutral conditions (28°C). Recordings were made with high temporal resolution (5-s bin) and the effects of LPS were compared with those induced by a tail-pinch, a standard arousing somato-sensory stimulus. At each dose, LPS moderately elevated brain, muscle, and skin temperatures. In contrast to rapid, monophasic and relatively short hyperthermic responses induced by a tail-pinch, LPS-induced increases in brain and muscle temperatures occurred with ~40 min onset latencies, showed three not clearly defined phases, were slightly larger with the 10 μm/kg dose, and maintained for the entire 4-hour post-injection recording duration. Based on dynamics of brain-muscle and skin-muscle temperature differentials, it appears that the hyperthermic response induced by LPS at the lowest dose originates from enhanced peripheral heat production, with no evidence of brain metabolic activation and skin vasoconstriction. While peripheral heat production also appears to determine the first phase of brain and body temperature elevation with LPS at 10 μg/kg, a further prolonged increase in brain-muscle differentials (onset at ~100 min) suggests metabolic brain activation as a factor contributing to brain and body hyperthermia. At this dose, skin temperature increase was weaker than in temporal muscle, suggesting vasoconstriction as another contributor to brain/body hyperthermia. Therefore, although both LPS at low doses and salient sensory stimuli moderately increase brain and body temperatures, these hyperthermic responses have important qualitative differences, reflecting unique underlying mechanisms.

  8. Measuring the absorbed dose in critical organs during low rate dose brachytherapy with 137 Cs using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Torres, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J.; Andres, U.; Mendez, G.

    2003-01-01

    Intracavitary Brachytherapy is one of the most used methods for the treatment of the cervical-uterine cancer. This treatment consists in the insertion of low rate dose 137 Cs sources into the patient. The most used system for the treatment dose planning is that of Manchester. This planning is based on sources, which are considered fixed during the treatment. However, the experience has shown that, during the treatment, the sources could be displaced from its initial position, changing the dose from that previously prescribed. For this reason, it is necessary to make measurements of the absorbed dose to the surrounding organs (mainly bladder and rectum). This paper presents the results of measuring the absorbed dose using home-made LiF: Mg, Cu, P + Ptfe thermoluminescent dosimeters (TLD). Measurements were carried out in-vivo during 20 minutes at the beginning and at the end of the treatments. Results showed that the absorbed dose to the critical organs vary significantly due to the movement of the patient during the treatment. (Author)

  9. Peripheral Neuropathy: A Practical Approach to Diagnosis and Symptom Management.

    Science.gov (United States)

    Watson, James C; Dyck, P James B

    2015-07-01

    Peripheral neuropathy is one of the most prevalent neurologic conditions encountered by physicians of all specialties. Physicians are faced with 3 distinct challenges in caring for patients with peripheral neuropathy: (1) how to efficiently and effectively screen (in less than 2 minutes) an asymptomatic patient for peripheral neuropathy when they have a disorder in which peripheral neuropathy is highly prevalent (eg, diabetes mellitus), (2) how to clinically stratify patients presenting with symptoms of neuropathy to determine who would benefit from specialty consultation and what testing is appropriate for those who do not need consultation, and (3) how to treat the symptoms of painful peripheral neuropathy. In this concise review, we address these 3 common clinical scenarios. Easily defined clinical patterns of involvement are used to identify patients in need of neurologic consultation, the yield of laboratory and other diagnostic testing is reviewed for the evaluation of length-dependent, sensorimotor peripheral neuropathies (the most common form of neuropathy), and an algorithmic approach with dosing recommendations is provided for the treatment of neuropathic pain associated with peripheral neuropathy. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  10. Advances in absorbed dose measurement standards at the australian radiation laboratory

    International Nuclear Information System (INIS)

    Boas, J.F.; Hargrave, N.J.; Huntley, R.B.; Kotler, L.H.; Webb, D.V.; Wise, K.N.

    1996-01-01

    The applications of ionising radiation in the medical and industrial fields require both an accurate knowledge of the amount of ionising radiation absorbed by the medium in question and the capability of relating this to National and International standards. The most useful measure of the amount of radiation is the absorbed dose which is defined as the energy absorbed per unit mass. For radiotherapy, the reference medium is water, even though the measurement of the absorbed dose to water is not straightforward. Two methods are commonly used to provide calibrations in absorbed dose to water. The first is the calibration of the chamber in terms of exposure in a Cobalt-60 beam, followed by the conversion by a protocol into dose to water in this and higher energy beams. The other route is via the use of a graphite calorimeter as a primary standard device, where the conversion from absorbed dose to graphite to absorbed dose in water is performed either by theoretical means making use of cavity ionisation theory, or by experiment where the graphite calorimeter and secondary standard ionisation chamber are placed at scaled distances from the source of the radiation beam (known as the Dose-Ratio method). Extensive measurements have been made at Cobalt-60 at ARL using both the exposure and absorbed dose to graphite routes. Agreement between the ARL measurements and those based on standards maintained by ANSTO and NPL is within ± 0.3%. Absorbed dose measurements have also been performed at ARL with photon beams of nominal energy 16 and 19 MeV obtained from the ARL linac. The validity of the protocols at high photon energies, the validity of the methods used to convert from absorbed dose in graphite to absorbed dose in water and the validity of the indices used to specify the beams are discussed. Brief mention will also be made of the establishment of a calibration facility for neutron monitors at ARL and of progress in the development of ERP dosimetry

  11. Advances in absorbed dose measurement standards at the australian radiation laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Boas, J.F.; Hargrave, N.J.; Huntley, R.B.; Kotler, L.H.; Webb, D.V.; Wise, K.N. [Australian Radiation Laboratory, Yallambie, VIC (Australia)

    1996-12-31

    The applications of ionising radiation in the medical and industrial fields require both an accurate knowledge of the amount of ionising radiation absorbed by the medium in question and the capability of relating this to National and International standards. The most useful measure of the amount of radiation is the absorbed dose which is defined as the energy absorbed per unit mass. For radiotherapy, the reference medium is water, even though the measurement of the absorbed dose to water is not straightforward. Two methods are commonly used to provide calibrations in absorbed dose to water. The first is the calibration of the chamber in terms of exposure in a Cobalt-60 beam, followed by the conversion by a protocol into dose to water in this and higher energy beams. The other route is via the use of a graphite calorimeter as a primary standard device, where the conversion from absorbed dose to graphite to absorbed dose in water is performed either by theoretical means making use of cavity ionisation theory, or by experiment where the graphite calorimeter and secondary standard ionisation chamber are placed at scaled distances from the source of the radiation beam (known as the Dose-Ratio method). Extensive measurements have been made at Cobalt-60 at ARL using both the exposure and absorbed dose to graphite routes. Agreement between the ARL measurements and those based on standards maintained by ANSTO and NPL is within {+-} 0.3%. Absorbed dose measurements have also been performed at ARL with photon beams of nominal energy 16 and 19 MeV obtained from the ARL linac. The validity of the protocols at high photon energies, the validity of the methods used to convert from absorbed dose in graphite to absorbed dose in water and the validity of the indices used to specify the beams are discussed. Brief mention will also be made of the establishment of a calibration facility for neutron monitors at ARL and of progress in the development of ERP dosimetry.

  12. Unit of measurement used and parent medication dosing errors.

    Science.gov (United States)

    Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L

    2014-08-01

    Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.

  13. Estimation of Electron Dose Delivered by a 0.4 MeV Accelerator from Bremsstrahlung Dose Measurements

    DEFF Research Database (Denmark)

    Karadjov, A. G.; Hansen, Jørgen-Walther

    1980-01-01

    Determination of a 0.4 MeV electron dose from a bremsstrahlung dose measurement using a converter-detector system is considered. The detector used is a Frickle dosimeter, and the converters are aluminum, copper and lead foils. Optimal converter thickness is ascertained experimentally for each mat...... materials within a Z-range of 13–82. A linear relation is found between bremsstrahlung dose and electron dose ranging from 2 to 20 Mrad. Finally the effect of converter area on detector response is studied....

  14. Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker.

    Science.gov (United States)

    Peet, Samuel C; Wilks, Rachael; Kairn, Tanya; Crowe, Scott B

    2016-12-01

    This study investigated the dose absorbed by tissues surrounding artificial cardiac pacemakers during external beam radiotherapy procedures. The usefulness of out-of-field reference data, treatment planning systems, and skin dose measurements to estimate the dose in the vicinity of a pacemaker was also examined. Measurements were performed by installing a pacemaker onto an anthropomorphic phantom, and using radiochromic film and optically stimulated luminescence dosimeters to measure the dose in the vicinity of the device during the delivery of square fields and clinical treatment plans. It was found that the dose delivered in the vicinity of the cardiac device was unevenly distributed both laterally and anteroposteriorly. As the device was moved distally from the square field, the dose dropped exponentially, in line with out-of-field reference data in the literature. Treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3D conformal treatments. The skin dose was observed to be either greater or lesser than the dose received at the depth of the device, depending on the treatment site, and so care should be if skin dose measurements are to be used to estimate the dose to a pacemaker. Square field reference data may be used as an upper estimate of absorbed dose per monitor unit in the vicinity of a cardiac device for complex treatments involving multiple gantry angles. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Measurements of dose with individual FAMOS transistors

    Energy Technology Data Exchange (ETDEWEB)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-12-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events.

  16. Measurements of dose with individual FAMOS transistors

    International Nuclear Information System (INIS)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-01-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events

  17. Trend of collective dose and dose reduction measures of Mitsubishi Electric Corporation workers in nuclear power plants

    International Nuclear Information System (INIS)

    Yamato, I.; Nakayama, T.; Shimokawa, F.; Yamamoto, T.

    1996-01-01

    MELCO has supplied the reactor instrumentation control system, reactor coolant pump motors, turbine generator and central control system for the pressurized water type nuclear power plant. For the legal periodical inspection and repair work, MELCO has also received orders for the periodical inspection for 23 power plants (including 4 plants under construction) of 5 electric power companies, and executed the inspection work from the view point of preventive maintenance. The annual dose for MELCO's workers is liable to be decreased in spite of increased number of plants. The dose for new plant in particular is 50, or less as compared with that for conventional plant. This is because the measures taken for the conventional plant against the dose reduction is reflected upon the new plant. The dose reduction measures are taken for each system for which order was received. Such measures are mainly intended to improve the work procedures and equipment for reduction of work time in the radioactive area and to arrange the working process, so as to perform the work in such period when the dose level at the working environment is low. To enhance the workers' consciousness for reduction of dose, MELCO provided the workers with dose predictive training, and let them aware of such items known at the tool box briefing (TBX), which could realize the dose reduction for workers. MELCO has been positively promoting the activity to arrange the desirable work environment for extermination of 3Ks (giken, gitsui, titanai) or 3Ds (dangerous, difficult, dirty) including protection against radiation in corporation with electric power companies. (author)

  18. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  19. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  20. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  1. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  2. Measurement of radiation dose with a PC-based instrument

    International Nuclear Information System (INIS)

    Jangland, L.; Neubeck, R.

    1994-01-01

    The purpose of this study was to investigate in what way the introduction of Digital Subtraction Angiography has influenced absorbed doses to the patient and personnel. Calculation of the energy imparted to the patient, ε, was based on measurements of the dose-area product, tube potential and tube current which were registered with a PC-based instrument. The absorbed doses to the personnel were measured with TLD. The measurements on the personnel were made only at the digital system. The results indicate large variations in ε between different types of angiographic examinations of the same type. The total ε were similar on both systems, although the relative contribution from image acquisition and fluoroscopy were different. At the conventional system fluoroscopy and image acquisition contributed almost equally to the total ε. At the digital system 25% of the total ε was due to fluoroscopy and 75% to image acquisition. The differences were due to longer fluoroscopic times on the conventional system, mainly due to lack of image memory and road mapping, and lower ε/image, due to lower dose settings to the film changer compared to the image intensifier on the digital system. 11 refs., 8 figs., 9 tabs

  3. Effect of body temperature on peripheral venous pressure measurements and its agreement with central venous pressure in neurosurgical patients.

    Science.gov (United States)

    Sahin, Altan; Salman, M Alper; Salman, A Ebru; Aypar, Ulka

    2005-04-01

    Previous studies suggest a correlation of central venous pressure (CVP) with peripheral venous pressure (PVP) in different clinical settings. The effect of body temperature on PVP and its agreement with CVP in patients under general anesthesia are investigated in this study. Fifteen American Society of Anesthesiologists I-II patients undergoing elective craniotomy were included in the study. CVP, PVP, and core (Tc) and peripheral (Tp) temperatures were monitored throughout the study. A total of 950 simultaneous measurements of CVP, PVP, Tc, and Tp from 15 subjects were recorded at 5-minute intervals. The measurements were divided into low- and high-Tc and -Tp groups by medians as cutoff points. Bland-Altman assessment for agreement was used for CVP and PVP in all groups. PVP measurements were within range of +/-2 mm Hg of CVP values in 94% of the measurements. Considering all measurements, mean bias was 0.064 mm Hg (95% confidence interval -0.018-0.146). Corrected bias for repeated measurements was 0.173 +/- 3.567 mm Hg (mean +/- SD(corrected)). All of the measurements were within mean +/- 2 SD of bias, which means that PVP and CVP are interchangeable in our setting. As all the measurements were within 1 SD of bias when Tc was > or = 35.8 degrees C, even a better agreement of PVP and CVP was evident. The effect of peripheral hypothermia was not as prominent as core hypothermia. PVP measurement may be a noninvasive alternative for estimating CVP. Body temperature affects the agreement of CVP and PVP, which deteriorates at lower temperatures.

  4. Ten Years Evidence-Based High-Tech Acupuncture—A Short Review of Peripherally Measured Effects

    Directory of Open Access Journals (Sweden)

    Gerhard Litscher

    2009-01-01

    Full Text Available Since 1997, the Research Unit of Biomedical Engineering in Anesthesia and Intensive Care Medicine of Graz Medical University has been dealing with the demystification of acupuncture and examining, using non-invasive methods, how different stimulation modalities (manual needle acupuncture, laserneedle acupuncture and electro acupuncture affect peripheral and central functions. Laser is also an important instrument for acupuncture. One only needs to mention the treatment of children or of patients with needle phobia. The laserneedle acupuncture, which was examined scientifically for the first time in Graz, represents a new painless acupuncture method for which up to ten laserneedles are glued to the skin, but not stuck into it. This first part of the short review article summarizes some of the peripherally measured effects of acupuncture obtained at the Medical University of Graz within the last 10 years.

  5. The antiproton depth–dose curve measured with alanine detectors

    CERN Document Server

    Bassler, Niels; Palmans, Hugo; Holzscheiter, Michael H; Kovacevic, Sandra

    2008-01-01

    n this paper we report on the measurement of the antiproton depth–dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen and Olsen for conversion of calculated dose into response. A good agreement is observed between the measured and calculated relative effectiveness although an underestimation of the measured values beyond the Bragg-peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use of the alanine detectors for dosimetry of mixed radiation fields.

  6. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  7. Potent analgesic effects of anticonvulsants on peripheral thermal nociception in rats

    Science.gov (United States)

    Todorovic, Slobodan M; Rastogi, A J; Jevtovic-Todorovic, Vesna

    2003-01-01

    Anticonvulsant agents are commonly used to treat neuropathic pain conditions because of their effects on voltage- and ligand-gated channels in central pain pathways. However, their interaction with ion channels in peripheral pain pathways is poorly understood. Therefore, we studied the potential analgesic effects of commonly used anticonvulsant agents in peripheral nociception. We injected anticonvulsants intradermally into peripheral receptive fields of sensory neurons in the hindpaws of adult rats, and studied pain perception using the model of acute thermal nociception. Commonly used anticonvulsants such as voltage-gated Na+ channel blockers, phenytoin and carbamazepine, and voltage-gated Ca2+ channel blockers, gabapentin and ethosuximide, induced dose-dependent analgesia in the injected paw, with ED50 values of 0.30, 0.32 and 8, 410 μg per 100 μl, respectively. Thermal nociceptive responses were not affected in the contralateral, noninjected paws, indicating a lack of systemic effects with doses of anticonvulsants that elicited local analgesia. Hill slope coefficients for the tested anticonvulsants indicate that the dose–response curve was less steep for gabapentin than for phenytoin, carbamazepine and ethosuximide. Our data strongly suggest that cellular targets like voltage-gated Na+ and Ca2+ channels, similar to those that mediate the effects of anticonvulsant agents in the CNS, may exist in the peripheral nerve endings of rat sensory neurons. Thus, peripherally applied anticonvulsants that block voltage-gated Na+ and Ca2+ channels may be useful analgesics. PMID:12970103

  8. Differences in micronucleus induction in peripheral blood reticulocytes of mice exposed to N-ethyl-N-nitrosourea at light and dark dosing times.

    Science.gov (United States)

    Itoh, Keiichi; Masumori, Shoji; Nakajima, Madoka; Hayashi, Makoto; Sakakibara, Hiroyuki; Shimoi, Kayoko

    2012-01-01

    Mammals, including human beings, have a circadian clock system to regulate behavioral and physiological processes. In this study, we investigated the effect of dosing time on micronucleus induction in the bone marrow by evaluating the frequencies of micronucleated peripheral reticulocytes (MNRETs) in mice exposed to N-ethyl-N-nitrosourea (ENU) to assess any difference in genotoxic sensitivity to chemicals between light and dark periods (inactive phase for rodents and active phase for rodents). Male C3H/He mice were treated intraperitoneally with ENU (12.5 or 25 mg/kg body weight) at zeitgeber time (ZT) 3 in the light period or ZT15 in the dark period, and then the time courses of the frequencies of the MNRETs were determined. The frequencies of the MNRETs induced by ENU increased time-dependently and peaked at 48 hr after treatment for ZT3 and ZT15, and were obviously higher in the ZT15 treatment group than the ZT3 treatment group. The MNRETs were measured at 48 hr after treatment with ENU (25 mg/kg body weight) at various dosing times (ZT0, 3, 6, 12, 15 and 18). The frequencies of the MNRETs in mice treated at ZT0, 15 and 18 were significantly higher than those in mice treated at ZT3, 6 and 12. These results suggest that genotoxic sensitivity to chemicals in mouse bone marrow is different between light and dark periods maybe due to different biological responses (detoxification, cell cycle, DNA repair, etc.) related to circadian rhythms.

  9. The incidence of phlebitis with intravenous amiodarone at guideline dose recommendations.

    Science.gov (United States)

    Slim, Ahmad M; Roth, Jason E; Duffy, Benjamin; Boyd, Sheri Y N; Rubal, Bernard J

    2007-12-01

    Postoperative atrial fibrillation following cardiothoracic surgery is common and frequently managed with intravenous (IV) amiodarone. Phlebitis is the most common complication with peripheral infusion of this agent. Current practice guidelines for peripheral IV administration of phlebitis. The present study examines the incidence of phlebitis in a postoperative patient population given current dose recommendations. A total of 273 patient charts were reviewed. The incidence of phlebitis in patients given IV amiodarone (n = 36) was 13.9% (95% confidence interval, 2.6-25.2%; p = 0.001). Logistic regression analysis with backward elimination of other therapeutic risk factors suggests that the odds ratio for phlebitis using current dose regimens without IV filters is 19-fold greater than baseline risk in this population. Phlebitis remains a significant complication associated with peripheral infusion of amiodarone within recommended dosing limits.

  10. Ambient dose measurement in some CT departments in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, S. A. H.

    2012-09-01

    Computerized Tomography (CT) is now one of the most important radiological examinations world wide.The frequency of CT examinations is increasing rapidly from 2% of all radiological examinations in some countries a decade age to 10-15% now. During the imaging procedure, staff may expose to a significant dose. Therefore, ambient dose measurement is important in the shortage of regular personal monitoring in sudan. This study intended to evaluate the ambient dose at some CT departments (Medical Military hospital, Alamal National Hospital, Elnelin Diagnostic Center and Modern Medical Centre). These departments were equipped with daul, 16 and 64 multi detector CT machines. A survey meter (Radios) was used to measure ambient doses in three locations: Doors, Control Rooms and Adjacent Rooms. The ambient dose equivalent (scatter dose) was measured at various distances from the isocenter of the CT unit at various angles to establish isodose cartography. The mean and range of radiation at control room is 10.00-0.20 and mean (7.05μSv/hr,) reception 1.0-0 (0.40) and doors 4.00-100.00 (73.5) for height 1 meter above the ground. For height 2 meters at control room 0-10.00 (6,75), reception 0-90.00 (30) at door 9.00-90.00 (49.50). This study confirms that low levels of radiation dose are received by staff during CT imaging and these levels are within safe limits as prescribed by the national and international regulations. (Author)

  11. The gonad dose produced by a 60Co irradiation of peripheral, interpleural, and retroperitoneal lymph node groups

    International Nuclear Information System (INIS)

    Hassenstein, E.; Nuesslin, F.; Medizinische Hochschule Hannover

    1976-01-01

    A telecobalt therapy of lymph node groups was simulated on the Alderson phantom and the gonad dose caused by each irradiation field was measured with LiF dosimeters. When the supradiaphragmatic and the para-aortal lymph nodes were irradiated, the ovary dose showed rates up to 20 per thousand of the dose maximum. The irradiation of the same zones brought about a testicle dose of less than 5 per thousand of the dose maximum, and only 1/20 of this rate was achieved when a lead plate of about four cm was used in order to protect the testicles. The results are discussed under the point of view of the genetic risk. (orig.) [de

  12. Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy

    Science.gov (United States)

    Jong, W. L.; Ung, N. M.; Tiong, A. H. L.; Rosenfeld, A. B.; Wong, J. H. D.

    2018-03-01

    The aim of this study is to investigate the fundamental dosimetric characteristics of the MOSkin detector for megavoltage electron beam dosimetry. The reproducibility, linearity, energy dependence, dose rate dependence, depth dose measurement, output factor measurement, and surface dose measurement under megavoltage electron beam were tested. The MOSkin detector showed excellent reproducibility (>98%) and linearity (R2= 1.00) up to 2000 cGy for 4-20 MeV electron beams. The MOSkin detector also showed minimal dose rate dependence (within ±3%) and energy dependence (within ±2%) over the clinical range of electron beams, except for an energy dependence at 4 MeV electron beam. An energy dependence correction factor of 1.075 is needed when the MOSkin detector is used for 4 MeV electron beam. The output factors measured by the MOSkin detector were within ±2% compared to those measured with the EBT3 film and CC13 chamber. The measured depth doses using the MOSkin detector agreed with those measured using the CC13 chamber, except at the build-up region due to the dose volume averaging effect of the CC13 chamber. For surface dose measurements, MOSkin measurements were in agreement within ±3% to those measured using EBT3 film. Measurements using the MOSkin detector were also compared to electron dose calculation algorithms namely the GGPB and eMC algorithms. Both algorithms were in agreement with measurements to within ±2% and ±4% for output factor (except for the 4 × 4 cm2 field size) and surface dose, respectively. With the uncertainties taken into account, the MOSkin detector was found to be a suitable detector for dose measurement under megavoltage electron beam. This has been demonstrated in the in vivo skin dose measurement on patients during electron boost to the breast tumour bed.

  13. Precedents For Authorization Of Contents Using Dose Rate Measurements

    International Nuclear Information System (INIS)

    Abramczyk, G.; Bellamy, S.; Nathan, S.; Loftin, B.

    2012-01-01

    For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

  14. Dose-area product measurement for patients in diagnostic radiography

    International Nuclear Information System (INIS)

    Alkhawad, Safaa Ibrahim Awad Elkarim

    2001-09-01

    There is a wide spread of the utilization of medical diagnostic x-ray in Sudan upon the last years, in private clinics as well as in public hospitals. The aim of this study was to measure the doses to patients from x-ray in radiography departments in Khartoum State. Use was made of ionization chamber that measures the product of dose times the exposed area of the patient in units of Gy cm 2 . The work was performed in 7 hospitals over 250 patients. 71.2% of the patients were males and 28.8% females. From this work, it appears that the chest radiography represent 42% of the total exposure of human body organs to radiography, there was also a clear variation in doses resulting from this exposure for different x-ray machines. The results of this study were compared with similar from Germany, Finland, New Zealand and Norway; which are recently available studies. The comparison showed those investigation of abdomen, spine and pelvis result in higher radiation doses. No data for limb exposure were obtained from these countries, in Sudan exposure of the limb carry radiation doses compared to the rest of the human body.(Author)

  15. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  16. Measurement of spatial dose-rate distribution using a position sensitive detector

    International Nuclear Information System (INIS)

    Emoto, T.; Torii, T.; Nozaki, T.; Ando, H.

    1994-01-01

    Recently, the radiation detectors using plastic scintillation fibers (PSF) have been developed to measure the positions exposed to radiation such as neutrons and high energy charged particles. In particular, the time of flight (TOF) method for measuring the difference of time that two directional signals of scintillation light reach both ends of a PSF is a rather simple method for the measurement of the spatial distribution of fast neutron fluence rate. It is possible to use the PSF in nuclear facility working areas because of its flexibility, small diameter and long length. In order to apply TOF method to measure spatial gamma dose rate distribution, the characteristic tests of a detector using PSFs were carried out. First, the resolution of irradiated positions and the counting efficiency were measured with collimated gamma ray. The sensitivity to unit dose rate was also obtained. The measurement of spatial dose rate distribution was also carried out. The sensor is made of ten bundled PSFs, and the experimental setup is described. The experiment and the results are reported. It was found that the PSF detector has the good performance to measure spatial gamma dose rate distribution. (K.I.)

  17. Interindividual variability in the dose-specific effect of dopamine on carotid chemoreceptor sensitivity to hypoxia

    Science.gov (United States)

    Limberg, Jacqueline K.; Johnson, Blair D.; Holbein, Walter W.; Ranadive, Sushant M.; Mozer, Michael T.

    2015-01-01

    Human studies use varying levels of low-dose (1-4 μg·kg−1·min−1) dopamine to examine peripheral chemosensitivity, based on its known ability to blunt carotid body responsiveness to hypoxia. However, the effect of dopamine on the ventilatory responses to hypoxia is highly variable between individuals. Thus we sought to determine 1) the dose response relationship between dopamine and peripheral chemosensitivity as assessed by the ventilatory response to hypoxia in a cohort of healthy adults, and 2) potential confounding cardiovascular responses at variable low doses of dopamine. Young, healthy adults (n = 30, age = 32 ± 1, 24 male/6 female) were given intravenous (iv) saline and a range of iv dopamine doses (1–4 μg·kg−1·min−1) prior to and throughout five hypoxic ventilatory response (HVR) tests. Subjects initially received iv saline, and after each HVR the dopamine infusion rate was increased by 1 μg·kg−1·min−1. Tidal volume, respiratory rate, heart rate, blood pressure, and oxygen saturation were continuously measured. Dopamine significantly reduced HVR at all doses (P HVR in the high group only (P HVR in the low group (P > 0.05). Dopamine infusion also resulted in a reduction in blood pressure (3 μg·kg−1·min−1) and total peripheral resistance (1–4 μg·kg−1·min−1), driven primarily by subjects with low baseline chemosensitivity. In conclusion, we did not find a single dose of dopamine that elicited a nadir HVR in all subjects. Additionally, potential confounding cardiovascular responses occur with dopamine infusion, which may limit its usage. PMID:26586909

  18. The Predictive Value of Inflammation-Related Peripheral Blood Measurements in Cancer Staging and Prognosis

    Directory of Open Access Journals (Sweden)

    Joanna L. Sylman

    2018-03-01

    Full Text Available In this review, we discuss the interaction between cancer and markers of inflammation (such as levels of inflammatory cells and proteins in the circulation, and the potential benefits of routinely monitoring these markers in peripheral blood measurement assays. Next, we discuss the prognostic value and limitations of using inflammatory markers such as neutrophil-to-lymphocyte and platelet-to-lymphocyte ratios and C-reactive protein measurements. Furthermore, the review discusses the benefits of combining multiple types of measurements and longitudinal tracking to improve staging and prognosis prediction of patients with cancer, and the ability of novel in silico frameworks to leverage this high-dimensional data.

  19. Direct measurement of annual β dose using TLD on porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Xia Junding; Wang Weida; Zhou Zhixin

    1999-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of direct measurement of annual β dose using ultrathin TLD (CaSO 4 :Tm) on porcelain was studied. Since the TLD was placed into a hole left after sampling for the TL measurement, the method will not cause any new damage to the studied object. The results show that the technique is suitable for measuring annual β dose and improving accuracy of TL authentication test for both porcelain and pottery

  20. Real-time measurement and monitoring of absorbed dose for electron beams

    Science.gov (United States)

    Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-09-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.

  1. Real-time measurement and monitoring of absorbed dose for electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, Sergey E-mail: sergey_korenev@steris.com; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-10-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.

  2. Real-time measurement and monitoring of absorbed dose for electron beams

    International Nuclear Information System (INIS)

    Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-01-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators

  3. Fiber optical dose rate measurement based on the luminescence of beryllium oxide

    Directory of Open Access Journals (Sweden)

    Teichmann Tobias

    2018-01-01

    Full Text Available This work presents a fiber optical dose rate measurement system based on the radioluminescence and optically stimulated luminescence of beryllium oxide. The system consists of a small, radiation sensitive probe which is coupled to a light detection unit with a long and flexible light guide. Exposing the beryllium oxide probe to ionizing radiation results in the emission of light with an intensity which is proportional to the dose rate. Additionally, optically stimulated luminescence can be used to obtain dose and dose rate information during irradiation or retrospectively. The system is capable of real time dose rate measurements in fields of high dose rates and dose rate gradients and in complex, narrow geometries. This enables the application for radiation protection measurements as well as for quality control in radiotherapy. One inherent drawback of fiber optical dosimetry systems is the generation of Cherenkov radiation and luminescence in the light guide itself when it is exposed to ionizing radiation. This so called “stem” effect leads to an additional signal which introduces a deviation in the dose rate measurement and reduces the spatial resolution of the system, hence it has to be removed. The current system uses temporal discrimination of the effect for radioluminescence measurements in pulsed radiation fields and modulated optically stimulated luminescence for continuous irradiation conditions. This work gives an overview of the major results and discusses new-found obstacles of the applied methods of stem discrimination.

  4. Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rehim, F; Said, F I.A.; Abdel-Fattah, A A [National Centre for Radiation Research and Technology, Atomic Energy Athority, P.O.Box 29 Nasr City, Cairo (Egypt)

    1996-03-01

    Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.

  5. Retrospective methods of dose assessment of the Chernobyl 'liquidators'. A comparison

    International Nuclear Information System (INIS)

    Schmidt, M.; Ziggel, H.; Schmitz-Feuerhaake, I.; Dannheim, B.; Schikalov, V.; Usatyj, A.; Shevchenko, V.; Snigireva, G.; Serezhenkov, V.; Klevezal, G.

    1998-01-01

    A database of biomedical and dosimetric data of participants in the liquidation work at Chernobyl was set up. Dose profiles were created by using suitable dose modelling. EPR spectrometric measurements of the tooth enamel was performed as a routine method of retrospective dosimetry for radiation workers at medium to low exposures. Chromosome analyses were carried out in peripheral blood lymphocytes of a cohort of the liquidation workers. Fluorescence in-situ hybridization was also used. The number of workers volunteering to take part in the research, however, was too small to allow statistically relevant results to be obtained. (P.A.)

  6. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield

    International Nuclear Information System (INIS)

    Fraass, B.A.; Kinsella, T.J.; Harrington, F.S.; Galtstein, E.

    1985-01-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy should preserve normal testicular function

  7. Radiation-related lymphopenia is associated with spleen irradiation dose during radiotherapy in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Liu, Jing; Zhao, Qianqian; Deng, Weiye; Lu, Jie; Xu, Xiaoqing; Wang, Renben; Li, Xia; Yue, Jinbo

    2017-05-30

    The decrease in peripheral blood lymphocytes induced by radiation lessens the antitumour effect of the immune response, which might cause immunosuppression. We aimed to investigate the correlation between the decrease in peripheral blood lymphocytes during radiotherapy (RT) and the spleen irradiation dose in patients with hepatocellular carcinoma (HCC). The subjects were 59 patients with HCC who had received RT from 2005 to 2014. The Min ALC (minimum value of absolute counts for peripheral blood lymphocytes) was collected from the routine workup for each patient prior to RT and weekly during RT. Spleen dose-volume variables, including the percentage of the organ volume receiving ≥ n Gy (V n ) and the mean spleen dose (MSD), were calculated using Eclipse treatment planning. Potential associations between dosimetric variables and the Min ALC were assessed by multiple linear regression analysis. Peripheral lymphocytes decreased during RT (P irradiation doses were significantly correlated with lower Min ALC during RT for HCC. V 5 should be limited in clinical practice. Maximum sparing for spleen irradiation during RT is recommended to preserve peripheral blood lymphocytes, which may decrease immunosuppression.

  8. Capillaroscopy as an Outcome Measure for Clinical Trials on the Peripheral Vasculopathy in SSc—Is It Useful?

    Directory of Open Access Journals (Sweden)

    Maurizio Cutolo

    2010-01-01

    Full Text Available Peripheral microvascular impairment in systemic sclerosis (SSc may be easily detected and scored in a safe noninvasive way by nailfold videocapillaroscopy (NVC. The paper highlights clinical conditions related to SSc in which NVC may represent an outcome measure of therapeutical interventions, by elaborating on their already assessed relationship with the NVC patterns and eventually scores. The 3 important biological/clinical conditions are: the positivity for SSc-specific serum autoantibodies, the presence of SSc skin digital ulcers (DUs and of pulmonary arterial hypertension (PAH SSc associated. In conclusion, to the question if capillaroscopy (NVC may represent in SSc an outcome measure for clinical trials on the peripheral vasculopathy, based on the growing evidence and our detailed studies, the answer is positive. Recent therapeutic trials in SSc are confirming this role, and the experience is growing rapidly.

  9. COMPUTED TOMOGRAPHY DOSE INDEX MEASUREMENT FOR Hi-ART MEGAVOLTAGE HELICAL CT.

    Science.gov (United States)

    Liu, Minglu; Wang, Yunlai; Liao, Xiongfei

    2016-11-01

    On-line megavoltage computed tomography (MVCT) images are used to verify patient daily set-up in Hi-ART helical TomoTherapy unit. To evaluate the patient dose from MVCT scanning in image guidance, weighted computed tomography (CT) dose index (CTDI w ) was measured with PTW TM30009 CT pencil chamber in head and body phantoms for slice thicknesses of 2, 4 and 6 mm with different scan lengths. Dose length products (DLPs) were subsequently calculated. The CTDI w and DLP were compared with XVI kV CBCT and Brilliance simulator CT for routine clinical protocols. It was shown that CTDI and DLP had close relationship with the slice thickness and the scan length. The dose distribution in the transversal plane was very inhomogeneous due to the attenuation of the couch. Patient dose from MVCT was lower than XVI CBCT for the head scan, while larger for body scan. CTDI w , which is measured easily and reproducibly, can be used to assess the patient dose in MVCT. Regular measurement should be performed in QA & QC programmes. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Measurements of cosmic-ray doses in commercial airline cabins

    International Nuclear Information System (INIS)

    Okano, M.; Fujitaka, K.; Izumo, K.

    1996-01-01

    Cosmic radiation doses which aircrew and air passengers receive in airplanes have been calling attention in many countries especially in the last decade. In this relation, various types of information had been reported on cosmic radiation intensity. In Japan, the cosmic radiation intensity had been measured in commercial airline cabins as well as chartered flights. While the intensity depends on altitude, geomagnetic latitude (or cutoff rigidity), and temporal variation of the solar activity, their doses are often speculated based on paper records on airflights combined with the intensity-altitude relationship. In this study, however, efforts were made to estimate more realistic integrated doses in airline cabins based on actual on-board measurements which had been conducted several dozens of times in each year (e.g., 45 times in 1994 and 27 times in 1995). (author)

  11. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  12. FBX dosimetry for point dose measurements in head and neck cancer patients

    International Nuclear Information System (INIS)

    Balraj, A.; Thakur, P.K.; Bhatnagar, S.; Vidyasagar, P.B.; Nirhali, Amit; Semwal, M.K.

    2007-01-01

    FBX dosimeter is mainly based on the determination of the radiation dose from the chemical changes produced in an irradiated medium, which can be measured by Spectrophotometry or Colorimetry, for which adequate FBX solution of 2 ml required for measuring the optical density (OD). To measure the point dose using 2 ml solution may lead to error in the measured dose since the solution may occupy 2 cc volume of the point measured. In head and neck carcinoma patients, the treatment area involves curvatures. Fixing 2 ml vial at the body surface is difficult and leads to give wrong readings. In this study we have measured the entrance and exit dose by filling 0.5 ml solution in a flexible catheter and placed at a point in the patient body surface during the radiation treatment. The solution was diluted adding 1.5 ml distilled water to measure the OD in the colorimeter

  13. Surface dose measurements and comparison of unflattened and flattened photon beams

    Directory of Open Access Journals (Sweden)

    Ashokkumar Sigamani

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB and flattening filter free (FFF therapeutic photon beam for different square field sizes (FSs for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD is less significant in FFF beams when compared to the flattened beams at extended SSDs.

  14. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  15. Indoor gamma dose measurements in Gudalore (India) using TLD

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikandan, N.; Raghunath, V.M.

    2002-01-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO 4 : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h -1 and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 μSv y -1 , for the inhabitants of mud houses to 1406.3 μSv y -1 , for those living in terrace houses made of cement and brick

  16. Efficacy of a radiation absorbing shield in reducing dose to the interventionalist during peripheral endovascular procedures: a single centre pilot study.

    Science.gov (United States)

    Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J

    2015-06-01

    This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  17. Dosimetric evaluation of the OneDoseTM MOSFET for measuring kilovoltage imaging dose from image-guided radiotherapy procedures.

    Science.gov (United States)

    Ding, George X; Coffey, Charles W

    2010-09-01

    The purpose of this study is to investigate the feasibility of using a single-use dosimeter, OneDose MOSFET designed for in vivo patient dosimetry, for measuring the radiation dose from kilovoltage (kV) x rays resulting from image-guided procedures. The OneDose MOSFET dosimeters were precalibrated by the manufacturer using Co-60 beams. Their energy response and characteristics for kV x rays were investigated by using an ionization chamber, in which the air-kerma calibration factors were obtained from an Accredited Dosimetry Calibration Laboratory (ADCL). The dosimetric properties have been tested for typical kV beams used in image-guided radiation therapy (IGRT). The direct dose reading from the OneDose system needs to be multiplied by a correction factor ranging from 0.30 to 0.35 for kilovoltage x rays ranging from 50 to 125 kVp, respectively. In addition to energy response, the OneDose dosimeter has up to a 20% reduced sensitivity for beams (70-125 kVp) incident from the back of the OneDose detector. The uncertainty in measuring dose resulting from a kilovoltage beam used in IGRT is approximately 20%; this uncertainty is mainly due to the sensitivity dependence of the incident beam direction relative to the OneDose detector. The ease of use may allow the dosimeter to be suitable for estimating the dose resulting from image-guided procedures.

  18. Decreased UV-induced DNA repair synthesis in peripheral leukocytes from patients with the nevoid basal cell carcinoma syndrome

    International Nuclear Information System (INIS)

    Ringborg, U.; Lambert, B.; Landergen, J.; Lewensohn, R.

    1981-01-01

    The uv-induced DNA repair synthesis in peripheral leukocytes from 7 patients with the nevoid basal cell carcinoma syndrome was compared to that in peripheral leukocytes from 5 patients with basal cell carcinomas and 39 healthy subjects. A dose response curve was established for each individual, and maximum DNA repair synthesis was used as a measure of the capacity for DNA repair. The patients with the nevoid basal cell carcinoma syndrome had about 25% lower level of maximum DNA repair synthesis as compared to the patients with basal cell carcinomas and control individuals. The possibility that DNA repair mechanisms may be involved in the etiology to the nevoid basal cell carcinoma syndrome is discussed

  19. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  20. Area and environmental gamma dose monitoring at PINSTECH

    International Nuclear Information System (INIS)

    Javed, M.; Awan, M.A.; Ahmad, S.; Afsar, M.; Orfi, S.D.

    1986-11-01

    Radiation dose monitoring of various radioactive laboratories including PARR building, radioactive waste disposal area and the environment upto initial peripheral limits of PINSTECH has been carried out by TLD's installed at different locations. Average dose rates in terms of percentage of dose limits have been compiled. The results for the year 1985 have been discussed in this report. (author)

  1. Dose-response curve for blood exposed to gamma-neutron mixed field by conventional cytogenetic method

    International Nuclear Information System (INIS)

    Brandao, Jose Odinilson de C.; Souza, Priscilla L.G.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F.; Calixto, Merilane S.; Santos, Neide

    2009-01-01

    There is increasing concern about airline crew members (about one million worldwide) are exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mytogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to neutron-gamma mixes field. Blood was obtained from one healthy donor and exposed to two neutron-gamma mixed field from sources 241 AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL-CRCN/NE-PE-Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemid accumulation and 1000 well-spread metaphase figures were analyzed for the presence of dicentrics by two experienced scorers after painted by giemsa 5%. Our preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  2. Dose-response curve for blood exposed to gamma-neutron mixed field by conventional cytogenetic method

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Jose Odinilson de C.; Souza, Priscilla L.G.; Santos, Joelan A.L.; Vilela, Eudice C.; Lima, Fabiana F., E-mail: jodinilson@cnen.gov.b, E-mail: fflima@cnen.gov.b, E-mail: jasantos@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Calixto, Merilane S.; Santos, Neide, E-mail: santos_neide@yahoo.com.b [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Genetica

    2009-07-01

    There is increasing concern about airline crew members (about one million worldwide) are exposed to measurable neutrons doses. Historically, cytogenetic biodosimetry assays have been based on quantifying asymmetrical chromosome alterations (dicentrics, centric rings and acentric fragments) in mytogen-stimulated T-lymphocytes in their first mitosis after radiation exposure. Increased levels of chromosome damage in peripheral blood lymphocytes are a sensitive indicator of radiation exposure and they are routinely exploited for assessing radiation absorbed dose after accidental or occupational exposure. Since radiological accidents are not common, not all nations feel that it is economically justified to maintain biodosimetry competence. However, dependable access to biological dosimetry capabilities is completely critical in event of an accident. In this paper the dose-response curve was measured for the induction of chromosomal alterations in peripheral blood lymphocytes after chronic exposure in vitro to neutron-gamma mixes field. Blood was obtained from one healthy donor and exposed to two neutron-gamma mixed field from sources {sup 241}AmBe (20 Ci) at the Neutron Calibration Laboratory (NCL-CRCN/NE-PE-Brazil). The evaluated absorbed doses were 0.2 Gy; 1.0 Gy and 2.5 Gy. The dicentric chromosomes were observed at metaphase, following colcemid accumulation and 1000 well-spread metaphase figures were analyzed for the presence of dicentrics by two experienced scorers after painted by giemsa 5%. Our preliminary results showed a linear dependence between radiations absorbed dose and dicentric chromosomes frequencies. Dose-response curve described in this paper will contribute to the construction of calibration curve that will be used in our laboratory for biological dosimetry. (author)

  3. Structural changes in chromosomes of peripheral blood lymphocytes in monkeys subjected to long-term daily irradiation

    International Nuclear Information System (INIS)

    Kosichenko, L.P.

    1976-01-01

    During the period that lasted from 4 to 11 years after the cessation of the long-term daily gamma-irradiation the frequency of chromosome rearrangements in peripheral blood lymphocytes of monkeys exceeded the control level. The number of rearrangements did not change significantly with different total irradiation doses (from 826 to 3677r). The main type of structural chromosome rearrangements were symmetrical chromosome exchanges. Abnormal cell clones in peripheral lymphocytes in monkeys irradiated with low doses exhibited no selective advantages during the periods of investigation

  4. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  5. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  6. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  7. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  8. Measurement system for depth dose distribution in cancer therapy

    International Nuclear Information System (INIS)

    Nishizawa, Hiroshi; Fujiwara, Hirotsugu; Tsutaka, Yoshikazu; Ikeda, Ikuo

    1999-01-01

    An accurate estimation of an absorbed dose distribution in human tissue is indispensable to efficiently perform radiotherapy in humans. Previously, various methods for such estimation have been developed, however, there is some problem in those methods, it takes too long times (3-4 hours) to determine the absorbed dose distribution through scanning by ionization chamber in water phantom. So, a determination system of depth dose was developed with an aim to determine the absorbed dose of X-ray or electron beam in materials similar to human body. This system was composed of a detector including scintillation fibers which allows emission due to radio-interaction, CCD camera for determination of light distribution of the emission and personal computer for data processing. Though the accuracy of this system was ±2% similar to that of the conventional measuring method, measuring time was reduced to almost 5 min, markedly shorter than that of the conventional water phantom (3-4 hours). The efficacy of works including the adjustment of irradiation system, planning, etc. would be improved by application of this system. (M.N.)

  9. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  10. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  11. Phosphorylation of histone H2AX as an indicator of received dose of gamma radiation after whole-body irradiation of rats

    Directory of Open Access Journals (Sweden)

    Radim Havelek

    2011-01-01

    Full Text Available The aim of our study was to determine whether phosphorylation of histone H2AX can be used as an indicator of received dose of gamma radiation after whole-body irradiation of rats. Wistar rats were irradiated by 1-10 Gy of gamma radiation by 60Co source. Value LD50/60 was 7.37 (4.68-8.05 Gy. Histone H2AX is phosphorylated by ATM kinase on serine 139 (γH2AX quickly after the irradiation. It forms microscopically visible foci in the site of double strand breaks of DNA. Flow-cytometric method was used for quantitative detection. This study is the first one that evaluated dose-dependency of H2AX phosphorylation in peripheral lymphocytes of rats irradiated by whole-body dose 1-10 Gy. Our data show a dose-dependent increase in γH2AX in rat peripheral blood lymphocytes 1 h after whole-body irradiation by the dose of 1-10 Gy. We proved that phosphorylation of histone H2AX is a prompt and reliable indicator of the received radiation dose suitable for rapid measurement before the number of lymphocytes in peripheral blood starts to decrease. It can be used already 1 h after the irradiation for an estimation of the received dose of radiation. Blood samples can be stored in 4 °C for 23 h without significantly affecting the result.

  12. Dose rate measurement of a cobalt source 'Issledovatel' by means of Fricke dosimeter

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The results of measurements leading to the elaboration of a reliable and accurate dose rate determination for a cobalt irradiator 'Issledovatel' were presented. The dose measurements were done by means of classic Fricke dosimeter. The conclusions from measurements can be useful also for the dosimetry of other kinds of cobalt irradiators. The measurements were performed by a newly employed Laboratory for Measurements of Technological Doses staff and were a practical test of their proficiency in gamma ray dosimetry.

  13. Measurements Of Fingers Doses Of Staff Members In Nuclear Medicine Department

    International Nuclear Information System (INIS)

    AL LEHYANI, S.H.; SHOUSHA, H.A.; HASSAN, R.A.

    2009-01-01

    For some occupationally radiation exposed groups, the hands are more heavily exposed to ionizing radiation than the rest of the body. The Egyptian Atomic Energy Authority runs an extensive personal dosimetry service in Egypt, but finger doses have not been measured to a wide extent. In this study, the finger doses were measured for five different nuclear medicine staff occupational groups for which heavy irradiation of the hands was suspected. Finger doses were measured for nuclear medicine physicians, technologists, nurses and physicists. The nuclear medicine staff working with the radioactive materials wears two TLD dosimeters during the whole period, which lasted from 1 to 4 weeks. The staff performs their work on a regular basis throughout the month, and means annual doses were calculated for these groups. The doses to the fingers for the 99m Tc technologists and nurses of groups (2) and (3) were observed to be 30.24 ± 14.5 μSv/GBq (mean ± SD) and 30.37 ± 17.5 μSv/GBq, respectively. Similarly, the dose to the fingers for the 131 I technologists in group (5) was estimated to be 126.13 ± 38.2μSv/GBq. Finger doses for the physicians could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly but their doses were reported in millisieverts that accumulated in 1 week. The doses to the fingers of the physicist were 16.3±7.7 μSv/GBq. The maximum average finger dose in this study was found to be 2.8 mSv for the technologists handled therapeutic 131 I (group 5). It could be concluded that the maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y).

  14. Multiple dose study of the combined radiosensitizers Ro 03-8799 (pimonidazole) and SR 2508 (etanidazole)

    International Nuclear Information System (INIS)

    Bleehen, N.M.; Newman, H.F.; Maughan, T.S.; Workman, P.

    1989-01-01

    The hypoxic cell radiosensitizers Ro 03-8799 and SR 2508 have different clinical toxicities. The former produces an acute but transient central nervous system syndrome, whereas the latter produces cumulative peripheral neuropathy. Following single dose studies, an escalating multiple dose schedule using both drugs in combination showed no unexpected adverse reactions at lower doses. This study identifies the clinical tolerance and pharmacokinetics when doses in the region of the maximal tolerated dose are given to 26 patients receiving infusions of 0.75 g/m2 Ro 03-8799 and 2 g/m2 SR 2508 three times per week. At 15 doses, 3/4 patients experienced WHO grade 2 peripheral neuropathy, whereas at 12 doses 1/9 developed grade 2 and 6/9 developed grade 1 neuropathies. This represents a lower dose of SR 2508 than can be given alone suggesting that some interaction between the two drugs does exist in terms of chronic peripheral neurotoxicity. Pharmacokinetic studies show no adverse interactions between the two drugs and minimal inter-patient variation. From bivariate analysis, cumulative AUC for Ro 03-8799 has the most significant correlation with the development of peripheral neuropathy. Tumor drug concentrations normalized to the administered dose show mean values of 34 micrograms/g Ro 03-8799 and 76 micrograms/g SR 2508 30 minutes after infusion. These could be expected to produce a single dose sensitizer enhancement ratio of 1.5. The combination of the two sensitizers at the maximum tolerable dose may be expected to give an increased therapeutic efficacy over either drug alone

  15. Peripheral dose to the testes: the design and clinical use of a practical and effective gonadal shield.

    Science.gov (United States)

    Fraass, B A; Kinsella, T J; Harrington, F S; Glatstein, E

    1985-03-01

    A simple and practical gonadal shield has been developed for use near megavoltage radiation fields. The lead shield encloses only the testes, allowing its use with nearly any radiation field that does not include the testes. The dose to the testes with and without the shield has been measured extensively both in phantoms and on patients. The gonadal shield allows a 3 to 10-fold reduction in dose to the testes depending primarily on the distance from the field edge to the gonads. When the shield is used, the gonadal dose is always less than 1% of the patient's prescription dose. Based on our patient studies of testicular injury following conventionally-fractionated irradiation, a dose of less than 50 cGy (1% of a typical 5000 cGy treatment regimen) should preserve normal testicular function.

  16. Assessment of dose measurement uncertainty using RisoScan

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Miller, Arne

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer

  17. Some measurements of doses to patients from dental X-rays

    International Nuclear Information System (INIS)

    Woehni, T.

    1976-01-01

    Some measurements of doses to patients from conventional dental radiography and orthopantomography are presented. Doses to the red bone marrow are calculated. The bone marrow doses from two different exposures, Maxilla incisor and Molar bite-wing, were calculated to be 0.4 and 1.0 mrad respectively. The average dose to red bone marrow from a full-mouth examination (10 exposures) was 0.7 mrad/exposure. An orthopantomographic examination involved 2 mrad to the bone marrow. The greatest doses from an orthopantomographic examination were found around the lateral rotational axis, namely 700 mrad. The dose distributions from the two different cone lengths did not differ as much as expected, mainly due to scattered radiation. (Auth.)

  18. Some measurements of doses to patients from dental X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T [Statens Institutt for Straalehygiene, Oslo (Norway)

    1976-11-01

    Some measurements of doses to patients from conventional dental radiography and orthopantomography are presented. Doses to the red bone marrow are calculated. The bone marrow doses from two different exposures, Maxilla incisor and Molar bite-wing, were calculated to be 0.4 and 1.0 mrad respectively. The average dose to red bone marrow from a full-mouth examination (10 exposures) was 0.7 mrad/exposure. An orthopantomographic examination involved 2 mrad to the bone marrow. The greatest doses from an orthopantomographic examination were found around the lateral rotational axis, namely 700 mrad. The dose distributions from the two different cone lengths did not differ as much as expected, mainly due to scattered radiation.

  19. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    Science.gov (United States)

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  1. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    International Nuclear Information System (INIS)

    Power, S.; Mirza, M.; Thakorlal, A.; Ganai, B.; Gavagan, L. D.; Given, M. F.; Lee, M. J.

    2015-01-01

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study

  2. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Power, S.; Mirza, M.; Thakorlal, A.; Ganai, B.; Gavagan, L. D.; Given, M. F.; Lee, M. J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Imaging and Interventional Radiology Department (Ireland)

    2015-06-15

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  3. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide,

  4. Phantom measurements and computed estimates of breast dose with radiotherapy for Hodgkin's lymphoma: dose reduction with the use of the involved field

    International Nuclear Information System (INIS)

    Wirth, A.; Kron, T.; Sorell, G.; Cramb, J.; Wittwer, H.; Sullivan, K.

    2008-01-01

    Full text: The risk of breast cancer following radiotherapy for Hodgkin's lymphoma appears to be dose related. In this study we compared breast dose in an anthropomorphic phantom for conventional 'mantle'; upper mediastinal/bilateral neck (minimantle) and unilateral neck fields, and evaluated the accuracy of computer planned dose estimates for out-of-field doses. For each field, computer-planned breast dose (CPD) estimates were compared with thermolu-minescence dosimetry measurements in five locations within 'breast tissue'. CPD were also compared with ion chamber measurements in a slab phantom. Measured dose and CPD were within 20% of each other up to approximately 10 cm from the field edge. Beyond 10 cm, the CPD underestimated dose by a factor of 2 or more. The minimantle reduced the breast dose by a factor of approximately 10 compared with the mantle treatment. Treating the neck field lowered the breast dose by a further 50% or more. Modern involved-field radiotherapy for lymphoma substantially reduces breast dose compared with mantle fields. Computer dosimetery underestimated dose at larger distances from the field. This needs to be considered if computer dosimetery is used to estimate breast dose and, by extrapolation, breast cancer risk.

  5. Neutron and gamma dose and spectra measurements on the Little Boy replica

    International Nuclear Information System (INIS)

    Hoots, S.; Wadsworth, D.

    1984-01-01

    The radiation-measurement team of the Weapons Engineering Division at Lawrence Livermore National Laboratory (LLNL) measured neutron and gamma dose and spectra on the Little Boy replica at Los Alamos National Laboratory (LANL) in April 1983. This assembly is a replica of the gun-type atomic bomb exploded over Hiroshima in 1945. These measurements support the National Academy of Sciences Program to reassess the radiation doses due to atomic bomb explosions in Japan. Specifically, the following types of information were important: neutron spectra as a function of geometry, gamma to neutron dose ratios out to 1.5 km, and neutron attenuation in the atmosphere. We measured neutron and gamma dose/fission from close-in to a kilometer out, and neutron and gamma spectra at 90 and 30 0 close-in. This paper describes these measurements and the results. 12 references, 13 figures, 5 tables

  6. Real-time personal dose measurement and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Liu Zhengshan; Yang Huating; Deng Changming; Zhang Xiu; Guo Zhanjie

    2001-01-01

    The composition and design of a real-time personal dose measurement and management system are described. Accordingly, some pertinent hardware circuits and software codes including their operation modes are presented

  7. Changes in peripheral blood level of regulatory T cells in patients with malignant melanoma during treatment with dendritic cell vaccination and low-dose IL-2

    DEFF Research Database (Denmark)

    Bjoern, J; Brimnes, M K; Andersen, M H

    2011-01-01

    In this study, changes in peripheral blood regulatory T cell (Treg) levels were evaluated in 46 progressive patients with melanoma treated with a dendritic cell-based vaccine and concomitant low-dose IFN-α and IL-2. The regulatory subset of CD4 T cells, characterized by CD25(high......) , was prospectively analysed in fresh blood, and treatment-associated quantitative and qualitative changes were analysed. By the 4th vaccine, patients showed a marked increase in CD4+ CD25(high) T cell subset from 6% to 22% (P...

  8. Changes in peripheral blood level of regulatory T cells in patients with malignant melanoma during treatment with dendritic cell vaccination and low-dose IL-2

    DEFF Research Database (Denmark)

    Bjoern, J; Brimnes, M K; Andersen, M H

    2011-01-01

    In this study, changes in peripheral blood regulatory T cell (Treg) levels were evaluated in 46 progressive patients with melanoma treated with a dendritic cell-based vaccine and concomitant low-dose IFN-a and IL-2. The regulatory subset of CD4 T cells, characterized by CD25(high......) , was prospectively analysed in fresh blood, and treatment-associated quantitative and qualitative changes were analysed. By the 4th vaccine, patients showed a marked increase in CD4+ CD25(high) T cell subset from 6% to 22% (P...

  9. Measurement of exposure dose rate by TLD in 60Co garden

    International Nuclear Information System (INIS)

    Fan Chengfang; Li Pinfang; Wu Maoliang; Zhao Quan

    1987-01-01

    The use of TLD method to measure exposure dose rate in 60 Co garden is described. As compared with chemical dosimetry, the relative deviation of measurement would not exceed 10%. The good repeatability has been proved by comparing the measurements of different times and distances with correction of decay law and 1/1 2 law. Besides, the distribution of exposure dose rate was influenced by scattering of the living plants

  10. Indoor gamma dose measurements in Gudalore (India) using TLD

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R.; Selvasekarapandian, S. E-mail: spandian@bharathi.ernet.in; Mugunthamanikandan, N.; Raghunath, V.M

    2002-06-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO{sub 4} : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h{sup -1} and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 {mu}Sv y{sup -1}, for the inhabitants of mud houses to 1406.3 {mu}Sv y{sup -1}, for those living in terrace houses made of cement and brick.

  11. Effect of limb cooling on peripheral and global oxygen consumption in neonates.

    Science.gov (United States)

    Hassan, I A-A; Wickramasinghe, Y A; Spencer, S A

    2003-03-01

    To evaluate peripheral oxygen consumption (VO(2)) measurements using near infrared spectroscopy (NIRS) with arterial occlusion in healthy term neonates by studying the effect of limb cooling on peripheral and global VO(2). Twenty two healthy term neonates were studied. Peripheral VO(2) was measured by NIRS using arterial occlusion and measurement of the oxyhaemoglobin (HbO(2)) decrement slope. Global VO(2) was measured by open circuit calorimetry. Global and peripheral VO(2) was measured in each neonate before and after limb cooling. In 10 neonates, a fall in forearm temperature of 2.2 degrees C (mild cooling) decreased forearm VO(2) by 19.6% (p forearm temperature of 4 degrees C (moderate cooling) decreased forearm VO(2) by 34.7% (p cooling. The changes are more pronounced with moderate limb cooling when a concomitant rise in global VO(2) is observed. Change in peripheral temperature must be taken into consideration in the interpretation of peripheral VO(2) measurements in neonates.

  12. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  13. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  14. Dose-effect of ionizing radiation-induced PIG3 gene expression alteration in human lymphoblastoid AHH-1 cells and human peripheral blood lymphocytes.

    Science.gov (United States)

    Liu, Qing-Jie; Zhang, De-Qin; Zhang, Qing-Zhao; Feng, Jiang-Bin; Lu, Xue; Wang, Xin-Ru; Li, Kun-Peng; Chen, De-Qing; Mu, Xiao-Feng; Li, Shuang; Gao, Ling

    2015-01-01

    To identify new ionizing radiation (IR)-sensitive genes and observe the dose-effect of gene expression alteration (GEA) induced by IR. Microarray was used to screen the differentially expressed genes in human lymphoblastoid cells (AHH-1) using three doses of (60)Co γ-rays (0.5-8 Gy at 1 Gy/min). Given that p53-inducible gene 3 (PIG3) was consistently upregulated, the GEA of PIG3 in AHH-1 cells and human peripheral blood lymphocytes (HPBL) induced by γ-rays (1 Gy/min) was measured at messenger RNA (mRNA) and protein levels. The GEA of PIG3 in AHH-1 cells exposed to neutron radiation (californium-252, 0.073 Gy/min) was also quantified. PIG3 was one of the seven differentially expressed genes found in the microarray analysis. The PIG3 mRNA and protein levels in AHH-1 cells were significantly increased from 1-10 Gy of γ-rays 8-72 h or 8-168 h after exposure, respectively. The enhancement was also observed in AHH-1 cells from 0.4-1.6 Gy of neutrons 48 h post-irradiation. The PIG3 mRNA levels (mRNA copy numbers) in HPBL were significantly increased from 1-8 Gy of γ-rays within 4-24 h post-irradiation, but the highest increase in signal-to-noise responsiveness is approximately two-fold, which was less than that of AHH-1 (approximately 20-fold). IR can upregulate the PIG3 gene expression in AHH-1 and HPBL in the early phase after exposure; however, the IR induced expression levels of PIG3 are greater in AHH-1 than HPBL.

  15. Radiation dose measurements during kilovoltage-cone beam computed tomography imaging in radiotherapy

    Directory of Open Access Journals (Sweden)

    A Sathish Kumar

    2016-01-01

    Conclusion: Radiation dose to the eye, breast, and the surface of the pelvis have been arrived at during CBCT. The doses measured on patients agreed closely with those measured on humanoid phantom and with published values.

  16. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  17. Multilayer detector for skin absorbed dose measuring

    International Nuclear Information System (INIS)

    Osanov, D.P.; Panova, V.P.; Shaks, A.I.

    1985-01-01

    A method for skin dosimetry based on utilization of multilayer detectors and permitting to estimate distribution of absorbed dose by skin depth is described. The detector represents a set of thin sensitive elements separated by tissue-equivalent absorbers. Quantitative evaluation and forecasting the degree of radiation injury of skin are determined by the formula based on determination of the probability of the fact that cells are not destroyed and they can divide further on. The given method ensures a possibility of quantitative evaluation of radiobiological effect and forecasting clinical consequences of skin irradiation by results of corresponding measurements of dose by means of the miultilayer detector

  18. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  19. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  20. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  1. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54-56 Gy given in 9-7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size.

    Science.gov (United States)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-04-22

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003-2008, 41 patients with 42 lung tumors were treated with SBRT to 54-56 Gy in 9-7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16-48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10-55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures.

  2. The Antiproton Depth Dose Curve Measured with Alanine Detectors

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, Johnny Witterseh; Palmans, Hugo

    2008-01-01

    In this paper we report on the measurement of the antiproton depth dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen et Olsen for conversion of calculated dose...... into response. A good agreement was observed between the measured and calculated relative effectiveness although a slight underestimation of the calculated values in the Bragg peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use...... of the alanine detectors for dosimetry of mixed radiation fields....

  3. Methodic of the gamma-rays absorbed dose measurements on tooth enamel

    International Nuclear Information System (INIS)

    Linev, S.V.; Muravskij, V.A.; Mashevskij, A.A.; Ugolev, I.I.

    1997-01-01

    The analysis of the metrological aspects of the tooth enamel ESR dosimetry has been done. The sample preparation and measurement methods have been elaborated. The methods have passed metrological certification. The methods include tabletting of the mixture of tooth enamel powder and MnO paramagnetic centres concentration additional standard, two loops of additional irradiation of samples by 1 Gy dose and ESR-spectra measurements, calculation of absorbed dose by maximum likelihood algorithm. The algorithm of dose calculation uses enamel spectrum model with axial anisotropic spin-Hamiltonian based on 126 spectra of enamel samples. The algorithm takes into account spectra of the empty cavity, the tube for a sample, the glue and MnO standard. Certificated ESR-station is based on the ESR-analyser PS-100X. ESR-station provides tooth enamel absorbed dose measurements from 0.05 to 0.25 Gy with error 35%, and from 0.25 to 3 Gy with error 20%. The set of tooth enamel absorbed dose standard samples has been created and certificated for the purposes of ESR-station testing and certification. The set consists of 12 tabletted samples of tooth enamel irradiated by doses from 0.05 to 4 Gy. (authors). 7 refs., 1 tab., 2 figs

  4. Neutron dose and energy spectra measurements at Savannah River Plant

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Soldat, K.L.; Haggard, D.L.; Faust, L.G.; Tomeraasen, P.L.

    1987-08-01

    Because some workers have a high potential for significant neutron exposure, the Savannah River Plant (SRP) contracted with Pacific Northwest Laboratory (PNL) to verify the accuracy of neutron dosimetry at the plant. Energy spectrum and neutron dose measurements were made at the SRP calibrations laboratory and at several other locations. The energy spectra measurements were made using multisphere or Bonner sphere spectrometers, 3 He spectrometers, and NE-213 liquid scintillator spectrometers. Neutron dose equivalent determinations were made using these instruments and others specifically designed to determine dose equivalent, such as the tissue equivalent proportional counter (TEPC). Survey instruments, such as the Eberline PNR-4, and the thermoluminescent dosimeter (TLD)-albedo and track etch dosimeters (TEDs) were also used. The TEPC, subjectively judged to provide the most accurate estimation of true dose equivalent, was used as the reference for comparison with other devices. 29 refs., 43 figs., 13 tabs

  5. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

    International Nuclear Information System (INIS)

    Hälg, Roger A.; Besserer, Jürgen; Schneider, Uwe

    2012-01-01

    Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1

  6. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  7. Assessment of micro-dose biplanar radiography in lower limb measurements in children

    International Nuclear Information System (INIS)

    Lerisson, Heloise; Amzallag-Bellenger, Elisa; Cebulski-Delebarre, Aurelie; Boutry, Nathalie; Nectoux, Eric; Herbaux, Bernard; Desmulliez, Geoffrey; Duhamel, Alain; Drumez, Elodie

    2018-01-01

    To evaluate in children microdose protocol compared with low dose for lower limb alignment (LLA) measurements on biplanar radiography. Children 6 years or older were included. Height, weight and hip width were measured prior to imaging. Hip width allowed classifying children into morphotype M1 (width <25 cm), M2 (25-35 cm) or M3 (>35 cm) corresponding to predefined acquisition parameters (kV, mA, tube speed). Micro- and low-dose protocols were used alternately, with simultaneous acquisition of frontal and lateral radiographs. LLA measurements were performed by two independent observers (n = 526). In 15 children per morphotype, a third observer performed measurements twice (n = 180). Intraclass correlation coefficients and the dose (delivered, absorbed) were calculated. 100 girls and 160 boys (mean age = 11.7 years) were investigated: 74 M1 (mean BMI, 15.7kg/m 2 ), 149 M2 (19.8 kg/m 2 ) and 40 M3 (30.2 kg/m 2 ). With microdose, inter- and intra-observer agreement was >0.90 for lengths whatever the morphotype, 0.75-0.90 (M1) and >0.90 (M2, M3) for valgus/varus and flexion/hyperextension deviations. Dose reduction reached a factor of 8.5 and 5.4 for the delivered and absorbed dose respectively. Microdose could be used for LLA measurements in children and permits a significant dose reduction. (orig.)

  8. RaD-X: Complementary measurements of dose rates at aviation altitudes

    Science.gov (United States)

    Meier, Matthias M.; Matthiä, Daniel; Forkert, Tomas; Wirtz, Michael; Scheibinger, Markus; Hübel, Robert; Mertens, Christopher J.

    2016-09-01

    The RaD-X stratospheric balloon flight organized by the National Aeronautics and Space Administration was launched from Fort Sumner on 25 September 2015 and carried several instruments to measure the radiation field in the upper atmosphere at the average vertical cutoff rigidity Rc of 4.1 GV. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt) in cooperation with Lufthansa German Airlines supported this campaign with an independent measuring flight at the altitudes of civil aviation on a round trip from Germany to Japan. The goal was to measure dose rates under similar space weather conditions over an area on the Northern Hemisphere opposite to the RaD-X flight. Dose rates were measured in the target areas, i.e., around vertical cutoff rigidity Rc of 4.1 GV, at two flight altitudes for about 1 h at each position with acceptable counting statistics. The analysis of the space weather situation during the flights shows that measuring data were acquired under stable and moderate space weather conditions with a virtually undisturbed magnetosphere. The measured rates of absorbed dose in silicon and ambient dose equivalent complement the data recorded during the balloon flight. The combined measurements provide a set of experimental data suitable for validating and improving numerical models for the calculation of radiation exposure at aviation altitudes.

  9. Interindividual variability in the dose-specific effect of dopamine on carotid chemoreceptor sensitivity to hypoxia.

    Science.gov (United States)

    Limberg, Jacqueline K; Johnson, Blair D; Holbein, Walter W; Ranadive, Sushant M; Mozer, Michael T; Joyner, Michael J

    2016-01-15

    Human studies use varying levels of low-dose (1-4 μg·kg(-1)·min(-1)) dopamine to examine peripheral chemosensitivity, based on its known ability to blunt carotid body responsiveness to hypoxia. However, the effect of dopamine on the ventilatory responses to hypoxia is highly variable between individuals. Thus we sought to determine 1) the dose response relationship between dopamine and peripheral chemosensitivity as assessed by the ventilatory response to hypoxia in a cohort of healthy adults, and 2) potential confounding cardiovascular responses at variable low doses of dopamine. Young, healthy adults (n = 30, age = 32 ± 1, 24 male/6 female) were given intravenous (iv) saline and a range of iv dopamine doses (1-4 μg·kg(-1)·min(-1)) prior to and throughout five hypoxic ventilatory response (HVR) tests. Subjects initially received iv saline, and after each HVR the dopamine infusion rate was increased by 1 μg·kg(-1)·min(-1). Tidal volume, respiratory rate, heart rate, blood pressure, and oxygen saturation were continuously measured. Dopamine significantly reduced HVR at all doses (P HVR in the high group only (P HVR in the low group (P > 0.05). Dopamine infusion also resulted in a reduction in blood pressure (3 μg·kg(-1)·min(-1)) and total peripheral resistance (1-4 μg·kg(-1)·min(-1)), driven primarily by subjects with low baseline chemosensitivity. In conclusion, we did not find a single dose of dopamine that elicited a nadir HVR in all subjects. Additionally, potential confounding cardiovascular responses occur with dopamine infusion, which may limit its usage. Copyright © 2016 the American Physiological Society.

  10. Photon and neutron doses of the personnel using moisture and density measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V. [Greek Atomic Energy Commission, Agia Paraskevi, Attiki, 60092 (Greece)

    2006-07-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a {sup 137}Cs source for density measurements and an {sup 241}Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  11. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  12. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  13. Measurement of MV CT dose index for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Liao Xiongfei

    2010-01-01

    Objective: To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy. Methods: Weighted CT dose index (CTDI W ) was measured with PTW TM30009 CT ion chamber in head and body phantoms, respectively,for slice thicknesses of 2, 4, 6 mm with scanned range of 5 cm and 15 cm. Dose length products (DLP) were subsequently calculated. The CTDI W and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols. Results: An inverse relationship between CTDI and the slice thickness was found. The dose distribution was inhomogeneous owing to the attenuation of the couch. CTDI and DLP had close relationship with the slice thickness and the scanned range. Patient dose from MVCT was lower than XVI CBCT for head, but larger for body scan. Conclusions: CTDI W can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility. Regular measurement should be performed in QA and QC program. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. (authors)

  14. Global Inhibition of Reactive Oxygen Species (ROS) Inhibits Paclitaxel-Induced Painful Peripheral Neuropathy

    OpenAIRE

    Fidanboylu, Mehmet; Griffiths, Lisa A.; Flatters, Sarah J. L.

    2011-01-01

    Paclitaxel (Taxol (R)) is a widely used chemotherapeutic agent that has a major dose limiting side-effect of painful peripheral neuropathy. Currently there is no effective therapy for the prevention or treatment of chemotherapy-induced painful peripheral neuropathies. Evidence for mitochondrial dysfunction during paclitaxel-induced pain was previously indicated with the presence of swollen and vacuolated neuronal mitochondria. As mitochondria are a major source of reactive oxygen species (ROS...

  15. Effects of ionization chamber construction on dose measurements in a heterogeneity

    International Nuclear Information System (INIS)

    Mauceri, T.; Kase, K.

    1987-01-01

    Traditionally, measurements have been made in heterogeneous phantoms to determine the factors which should be applied to dose calculations, when calculating a dose to a heterogeneous medium. Almost all measurements have relied on relatively thin-walled ion chambers, with no attempt to match ion chamber wall material to the measuring medium. The recent AAPM dosimetry protocol has established that a mismatch between ion chamber wall and phantom material can have an effect on dose measurement. To investigate the affect of this mismatch of ion chamber wall material to phantom material, two parallel-plate ion chambers were constructed. One ion chamber from solid water, for measurements in a solid water phantom and the other from plastic lung material, for measurements in a plastic lung material phantom. Correction factors measured by matching ion chamber to media were compared to correction factors measured by using a thin-walled cavity ion chamber with no regard for matching wall and media for cobalt-60, 6-, 10- and 20-MV photon beams. The results demonstrated that the matching of ion chamber to measuring media can be ignored, provided that a small, approximately tissue-equivalent, thin-walled ion chamber is used for measuring the correction factors

  16. Online Radiation Dose Measurement System for ATLAS experiment

    CERN Document Server

    Mandić, I; The ATLAS collaboration

    2012-01-01

    Particle detectors and readout electronics in the high energy physics experiment ATLAS at the Large Hadron Collider at CERN operate in radiation field containing photons, charged particles and neutrons. The particles in the radiation field originate from proton-proton interactions as well as from interactions of these particles with material in the experimental apparatus. In the innermost parts of ATLAS detector components will be exposed to ionizing doses exceeding 100 kGy. Energetic hadrons will also cause displacement damage in silicon equivalent to fluences of several times 10e14 1 MeV-neutrons per cm2. Such radiation doses can have severe influence on the performance of detectors. It is therefore very important to continuously monitor the accumulated doses to understand the detector performance and to correctly predict the lifetime of radiation sensitive components. Measurements of doses are important also to verify the simulations and represent a crucial input into the models used for predicting future ...

  17. Optimal Scanning Protocols for Dual-Energy CT Angiography in Peripheral Arterial Stents: An in Vitro Phantom Study

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    2015-05-01

    Full Text Available Objective: To identify the optimal dual-energy computed tomography (DECT scanning protocol for peripheral arterial stents while achieving a low radiation dose, while still maintaining diagnostic image quality, as determined by an in vitro phantom study. Methods: Dual-energy scans in monochromatic spectral imaging mode were performed on a peripheral arterial phantom with use of three gemstone spectral imaging (GSI protocols, three pitch values, and four kiloelectron volts (keV ranges. A total of 15 stents of different sizes, materials, and designs were deployed in the phantom. Image noise, the signal-to-noise ratio (SNR, different levels of adaptive statistical iterative reconstruction (ASIR, and the four levels of monochromatic energy for DECT imaging of peripheral arterial stents were measured and compared to determine the optimal protocols. Results: A total of 36 scans with 180 datasets were reconstructed from a combination of different protocols. There was a significant reduction of image noise with a higher SNR from monochromatic energy images between 65 and 70 keV in all investigated preset GSI protocols (p < 0.05. In addition, significant effects were found from the main effect analysis for these factors: GSI, pitch, and keV (p = 0.001. In contrast, there was significant interaction on the unstented area between GSI and ASIR (p = 0.015 and a very high significant difference between keV and ASIR (p < 0.001. A radiation dose reduction of 50% was achieved. Conclusions: The optimal scanning protocol and energy level in the phantom study were GSI-48, pitch value 0.984, and 65 keV, which resulted in lower image noise and a lower radiation dose, but with acceptable diagnostic images.

  18. Measurement of doses to aviator pilots using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin N, J.; Cruz C, D.; Rivera M, T.

    2004-01-01

    During the development of their work, the aviator pilots are exposed at high levels of natural radiation of bottom caused mainly by the cosmic radiation of galactic origin and lot. For such reason, the Metropolitan Autonomous University (UAM) and the Union Association of Aviator Pilots (ASPA), subscribed an agreement with the purpose of to measure the doses of ionizing radiation received by the aviator pilots of diverse air companies that man different types of airships and to determine if these doses surpass the one limit of 0.11 mSv/h settled down by the IAEA for the public in general; and if therefore, these workers should be considered as personnel occupationally exposed. In this work the obtained results when measuring the absorbed dose received by Mexican civil aviator pilots during the development of their work, using thermoluminescent dosemeters of LiF:Mg,Cu,P + Ptfe of national production are presented. The obtained results during the years of 2001 and 2002 show that the monthly doses received by the pilots surpass the one it limits established for the public in general, for what they should be considered as personnel occupationally exposed. (Author)

  19. Measurement of radiotherapy CBCT dose in a phantom using different methods

    International Nuclear Information System (INIS)

    Hu, Naonori; McLean, Donald

    2014-01-01

    Cone beam computed tomography (CBCT) is used widely for the precise and accurate patient set up needed during radiation therapy, notably for hypo fractionated treatments, such as intensity modulated radiation therapy and stereotactic radiation therapy. Reported doses associated with CBCT indicate the potential to approach radiation tolerance levels for some critical organs. However while some manufacturers state the CBCT dose for each standard protocol, currently there are no standard or recognised protocols for CBCT dosimetry. This study has applied wide beam computed tomography dosimetry approaches as reported by the International Atomic Energy Agency and the American Association of Physicists in Medicine to investigate dosimetry for the Varian Trilogy linear accelerator with on-board imager v1.5. Three detection methods were used including (i) the use of both 100 mm and 300 mm pencil ionisation chambers, (ii) a 0.6 cm 3 ionisation chamber and (iii) gafchromic film. Measurements were performed using custom built 45 cm long PMMA phantoms as well as standard 15 cm long phantoms for both head and body simulation. The results showed good agreement between each other detector system (within 3 %). The measured CBCT dose for the above methods showed a large difference to the dose stated by Varian, with the measured dose being 40 % over the stated dose for the standard head protocol. This shows the importance of independently verifying the stated dose given by the vendor for standard procedures.

  20. Ionizing radiation population doses at Sao Paulo city, Brazil: open-pit gamma dose measurement

    International Nuclear Information System (INIS)

    Oliveira, Raimundo Enoch Rodrigues

    2001-01-01

    The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level) radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H * (10)) to which the people are exposed in the city of Sao Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H * (10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H * (10) varied from 33.1 to 152.3 nSv.h -1 , net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 n Sv.h -1 for an average for the city of Sao Paulo of 96.1(24) nSv.h -1 . In addition, average values of H * (10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order to verify the origin of the discrepancy. The mean value of H * (10) rate obtained for the city of Sao Paulo as converted to effective dose. in order to be compared with other places results It could be noticed that the annual average of effective dose for the city of Sao Paulo, 0.522(13) mSv, is superior to

  1. SU-E-T-322: Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, D; Sood, S; Badkul, R; Jiang, H; Kumar, P; Wang, F [University of Kansas Hospital, Kansas City, KS (United States)

    2015-06-15

    Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dose to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor

  2. SU-E-T-322: Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines

    International Nuclear Information System (INIS)

    Pokhrel, D; Sood, S; Badkul, R; Jiang, H; Kumar, P; Wang, F

    2015-01-01

    Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dose to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor

  3. In-vivo (entrance) dose measurements in external beam radiotherapy with aqueous FBX dosimetry system

    International Nuclear Information System (INIS)

    Semwal, M.K.; Thakur, P.K.; Bansal, A.K.; Vidyasagar, P.B.

    2005-01-01

    FBX aqueous chemical dosimetry system has been found useful in radiotherapy owing to its low dose measuring capability. In the present work, entrance dose measurements in external beam radiotherapy on a telecobalt machine were carried out with the system on 100 patients. Treatments involving simple beam arrangement of open parallel-opposed beams in cranial and pelvic irradiations were selected for this study. In place of a spectrophotometer, a simple and inexpensive colorimeter was used for absorbance measurements. The purpose was to assess the efficacy of the FBX system for in-vivo dose measurements. The results obtained show that the average discrepancy between the measured and expected dose for both categories of patients was 0.2% (standard deviation 3.2%) with a maximum of +1 0.3%. There were 5.5% cases showing more than ± 5% discrepancy. Comparison of the results obtained with published work on entrance dose measurements, with diode detectors, shows that the inexpensive FBX system can be used for in-vivo (entrance) dose measurements for simple beam arrangements in radiotherapy and can thus serve as a useful QA tool. (author)

  4. Mutagenicity of the Musa paradisiaca (Musaceae) fruit peel extract in mouse peripheral blood cells in vivo.

    Science.gov (United States)

    Andrade, C U B; Perazzo, F F; Maistro, E L

    2008-01-01

    Plants are a source of many biologically active products and nowadays they are of great interest to the pharmaceutical industry. In the present study, the mutagenic potential of the Musa paradisiaca fruit peel extract was assessed by the single-cell gel electrophoresis (SCGE) and micronucleus assays. Animals were treated orally with three different concentrations of the extract (1000, 1500, and 2000 mg/kg body weight). Peripheral blood cells of Swiss mice were collected 24 h after treatment for the SCGE assay and 48 and 72 h for the micronucleus test. The results showed that the two higher doses of the extract of M. paradisiaca induced statistically significant increases in the average numbers of DNA damage in peripheral blood leukocytes for the two higher doses and a significant increase in the mean of micronucleated polychromatic erythrocytes in the three doses tested. The polychromatic/normochromatic erythrocyte ratio scored in the treated groups was not statistically different from the negative control. The data obtained indicate that fruit peel extract from M. paradisiaca showed mutagenic effect in the peripheral blood cells of Swiss albino mice.

  5. Spectrum of chromosomal aberrations in peripheral lymphocytes of hospital workers occupationally exposed to low doses of ionizing radiation

    International Nuclear Information System (INIS)

    Maffei, Francesca; Angelini, Sabrina; Forti, Giorgio Cantelli; Violante, Francesco S.; Lodi, Vittorio; Mattioli, Stefano; Hrelia, Patrizia

    2004-01-01

    Chromosome aberrations frequency was estimated in peripheral lymphocytes from hospital workers occupationally exposed to low levels of ionizing radiation and controls. Chromosome aberrations yield was analyzed by considering the effects of dose equivalent of ionizing radiation over time, and of confounding factors, such as age, gender and smoking status. Frequencies of aberrant cells and chromosome breaks were higher in exposed workers than in controls (P=0.007, and P=0.001, respectively). Seven dicentric aberrations were detected in the exposed group and only three in controls, but the mean frequencies were not significantly different. The dose equivalent to whole body of ionizing radiation (Hwb) did appear to influence the spectrum of chromosomal aberrations when the exposed workers were subdivided by a cut off at 50 mSv. The frequencies of chromosome breaks in both subgroups of workers were significantly higher than in controls (≤50 mSv, P=0.041; >50 mSv, P=0.018). On the other hand, the frequency of chromatid breaks observed in workers with Hwb >50 mSv was significantly higher than in controls (P=0.015) or workers with Hwb ≤50 mSv (P=0.046). Regarding the influence of confounding factors on genetic damage, smoking status and female gender seem to influence the increase in chromosome aberration frequencies in the study population. Overall, these results suggested that chromosome breaks might provide a good marker for assessing genetic damage in populations exposed to low levels of ionizing radiation

  6. Dose measurement of ion implanted silicon by RBS technique

    International Nuclear Information System (INIS)

    Kamawanna, Teerasak; Intarasiri, Saweat; Prapunsri, Chowunchun; Thongleurm, Chome; Maleepatra, Saenee; Singkarat, Somsorn

    2003-10-01

    Surface modification can be achieved by ion implantation. This study used a 1 mm thick silicon wafer as a target which was implanted with Ar+ at 80 keV. The degree of the modification depends on both the ion energy and the implanted dose. The distribution of argon in the silicon substrate and the absolute implanted dose can be measured by using Rutherford Backscattering Spectrometry (RBS). These investigations utilized a 1.7 MV Tandetron accelerator system at Chiang Mai University. The dose determination by a direct calculation is in agreement with the simulation by the SIMNRA code

  7. Using RADFET for the real-time measurement of gamma radiation dose rate

    Science.gov (United States)

    Andjelković, Marko S.; Ristić, Goran S.; Jakšić, Aleksandar B.

    2015-02-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h-1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose.

  8. Using RADFET for the real-time measurement of gamma radiation dose rate

    International Nuclear Information System (INIS)

    Andjelković, Marko S; Ristić, Goran S; Jakšić, Aleksandar B

    2015-01-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h −1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose. (paper)

  9. Dose measurements in laboratory of Physics department, University of Khartoum

    International Nuclear Information System (INIS)

    Hamid, Maria Mohammed

    1999-05-01

    Personal monitoring in University of Khartoum is being conducted using thermoluminescent dosimetry. The purpose of the study is to measure the dose of radiation in laboratory of Physics in physics department. TL phosphors LiF: Mg, Ti (card) and LiF Mg, Cu, P (GR-200) and mini-rad dosimeter are used to measure the dose in laboratory. The total dose for students form the laboratory bu using card, GR-200 and mini-rad dosimeter was found to be 2.2μ sv/year. 2.5 μ sv/year and 2.6 μ sv respectively, and for the teacher about 4.0 μ sv/year, 5.8 μ sv/year and 13.6 μ sv/year respectively, and for the dose near junk room about 3.9 μ sv/year, 2.9 μ sv/year and 2.8 μ sv/year by using card, GR-200 and mini-rad dosimeter respectively. There is just a background radiation in the main library and the applied nuclear.(Author)

  10. Exact comparison of dose rate measurements and calculation of TN12/2 packages

    International Nuclear Information System (INIS)

    Taniuchi, H.; Matsuda, F.

    1998-01-01

    Both of dose rate measurements of TN 12/2 package and calculations by Monte Carlo code MORSE in SCALE code system and MCNP were performed to evaluate the difference between the measurement and the calculation and finding out the cause of the difference. The calculated gamma-ray dose rates agreed well with measured ones, but calculated neutron dose rates overestimated more than a factor of 1.7. When considering the cause of the difference and applying the modification into the neutron calculation, the calculated neutron dose rates become to agree well, and the factor decreased to around 1.3. (authors)

  11. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  12. Peripheral blood leukocyte count as an index of defense status in the leukopenic host

    International Nuclear Information System (INIS)

    Cawley, S.; Findon, G.; Miller, T.E.

    1988-01-01

    These experimental studies have investigated the reliability of the peripheral blood leukocyte count to predict whether the leukopenic host can contain or eliminate infection. Additionally, we have investigated the possibility that determination of leukocyte recruitment, supplementary to peripheral blood leukocyte counts, might allow individuals with neutropenia at risk from serious infection to be distinguished with greater certainty. Varying doses of radiation, cyclophosphamide, and methylprednisolone were used to induce distinct levels of leukopenia in rats. Leukocyte recruitment was measured by quantifying the response of neutropenic animals to evocative, subcutaneous stimuli, and the results of this assay were then compared with circulating leukocyte counts in the same individuals. Six models of experimentally induced infection were used to compare circulating and recruitable leukocytes as indicators of the susceptibility of the leukopenic host to infection. Response curves relating leukocyte numbers to host resistance were similar when circulating or recruitable leukocytes were used as an index of defense capability. These findings support the use of peripheral blood leukocyte numbers as an index of resistance to infection in individuals with leukopenia and suggest that functional analyses such as leukocyte recruitment are unlikely to provide additional information

  13. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  14. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  15. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  16. Dose to the uterus from radiotherapy procedures for breast carcinoma

    International Nuclear Information System (INIS)

    Martin Rincon, C.; Jerez Sainz, I.; Modolell Farre, I.; Espana Lopez, M.L.; Lopez Franco, P.

    2001-01-01

    In the early period of the pregnancy, the radiological protection of the unborn child is of particular concern. In several reports dose thresholds for deterministic effects as well as dose values that increase the probability of stochastic effects have been established. The aim of this article was to estimate the peripheral dose (PD) in order to evaluate the absorbed dose in utero for breast carcinoma treatment related to the radiotherapy procedures established in our hospital. The treatment was simulated using an anthropomorphic phantom Alderson-Rando, and two similar treatment planning with and without wedges were performed, taken into account the average field parameters used in 300 treatment planning patients. The PD values were determined with a NE 2571 ionization chamber in a General Electric linac for the treatments considered. Experimental measures provided dose in utero values slightly higher than 5 cGy, dose threshold established in some articles for radioinduced effects in the fetus. The planning system underestimated the PD values and no significant influence with the use of wedges was found. (author)

  17. Assessment of leakage dose in vivo in patients undergoing radiotherapy for breast cancer

    Directory of Open Access Journals (Sweden)

    Peta Lonski

    2018-01-01

    Full Text Available Background and purpose: Accurate quantification of the relatively small radiation doses delivered to untargeted regions during breast irradiation in patients with breast cancer is of increasing clinical interest for the purpose of estimating long-term radiation-related risks. Out-of-field dose calculations from commercial planning systems however may be inaccurate which can impact estimates for long-term risks associated with treatment. This work compares calculated and measured dose out-of-field and explores the application of a correction for leakage radiation. Materials and methods: Dose calculations of a Boltzmann transport equation solver, pencil beam-type, and superposition-type algorithms from a commercial treatment planning system (TPS were compared with in vivo thermoluminescent dosimetry (TLD measurements conducted out-of-field on the contralateral chest at points corresponding to the thyroid, axilla and contralateral breast of eleven patients undergoing tangential beam radiotherapy for breast cancer. Results: Overall, the TPS was found to under-estimate doses at points distal to the radiation field edge with a modern linear Boltzmann transport equation solver providing the best estimates. Application of an additive correction for leakage (0.04% of central axis dose improved correlation between the measured and calculated doses at points greater than 15 cm from the field edge. Conclusions: Application of a correction for leakage doses within peripheral regions is feasible and could improve accuracy of TPS in estimating out-of-field doses in breast radiotherapy. Keywords: Breast radiotherapy, TLD, Leakage dose, Dose calculation algorithm

  18. "Ecstasy" toxicity to adolescent rats following an acute low binge dose.

    Science.gov (United States)

    Teixeira-Gomes, Armanda; Costa, Vera Marisa; Feio-Azevedo, Rita; Duarte, José Alberto; Duarte-Araújo, Margarida; Fernandes, Eduarda; Bastos, Maria de Lourdes; Carvalho, Félix; Capela, João Paulo

    2016-06-28

    3,4-Methylenedioxymethamphetamine (MDMA or "ecstasy") is a worldwide drug of abuse commonly used by adolescents. Most reports focus on MDMA's neurotoxicity and use high doses in adult animals, meanwhile studies in adolescents are scarce. We aimed to assess in rats the acute MDMA toxicity to the brain and peripheral organs using a binge dose scheme that tries to simulate human adolescent abuse. Adolescent rats (postnatal day 40) received three 5 mg/kg doses of MDMA (estimated equivalent to two/three pills in a 50 kg adolescent), intraperitoneally, every 2 h, while controls received saline. After 24 h animal sacrifice took place and collection of brain areas (cerebellum, hippocampus, frontal cortex and striatum) and peripheral organs (liver, heart and kidneys) occurred. Significant hyperthermia was observed after the second and third MDMA doses, with mean increases of 1 °C as it occurs in the human scenario. MDMA promoted ATP levels fall in the frontal cortex. No brain oxidative stress-related changes were observed after MDMA. MDMA-treated rat organs revealed significant histological tissue alterations including vascular congestion, but no signs of apoptosis or necrosis were found, which was corroborated by the lack of changes in plasma biomarkers and tissue caspases. In peripheral organs, MDMA did not affect significantly protein carbonylation, glutathione, or ATP levels, but liver presented a higher vulnerability as MDMA promoted an increase in quinoprotein levels. Adolescent rats exposed to a moderate MDMA dose, presented hyperthermia and acute tissue damage to peripheral organs without signs of brain oxidative stress.

  19. Measurements of the Cosmic Rays Dose at Different Altitudes of Iran

    International Nuclear Information System (INIS)

    Faghihi, R.; Mehdizadeh, S.; Jafarizadeh, M.; Sina, S.; Zehtabian, M.; Taheri, M.

    2012-01-01

    The amount of cosmic rays varies widely with the altitude, latitude and longitude in each region. In this study, the radiation doses due to the cosmic rays were estimated in two steps: in the first step, the neutron and gamma components of the radiation dose were measured for a roundtrip flight on 3 flight routes (Shiraz-Asaluye, Asaluye-Rasht and Shiraz-Mashhad) using a gamma-tracer photon detector and a Thyac 190 N, neutron detector. The minimum values of the measured gamma and neutron doses of 0.15 and 0.04μSv were measured on the Asaluyeh-Shiraz route at the lowest altitude of 19000 ft, while for Rasht-Asaluyeh route at an altitude of 35000 ft those values were found to be 2.52 and 1.09 mSv, respectively. In the second step, a number of air crew members were equipped with thermoluminescence dosimeters (TLD cards) for evaluating the gamma dose and polycarbonate dosimeters (SSNTD) for assessing the neutron dose for one year. The measured value of the annual effective dose received by the crew ranged between 0.5 mSv/y and 1.16 mSv/y, with an average of 0.9 mSv/y for the gamma component and between 0.37 mSv/y and 0.77 mSv/y with an average of 0.61 mSv/y for the neutron component. The results of this investigation are comparable with the investigations that have been conducted in other countries. For instance in UK, the reported annual effective dose of air crew is about 2 mSv, and in Canada, it is estimated to be between 1 to 5 mSv, depending on the flight situations (such as the latitude and longitude of the cities, the flight altitude, etc).

  20. Study of the Radiochromic Film for High Dose Measurement in Radiation Processing

    Directory of Open Access Journals (Sweden)

    CHEN Yi-zhen

    2016-02-01

    Full Text Available To establish the radiochromic film dosimeter for high dose level measurement during radiation processing, By corresponding formula and its preparation process research, batches of radiochromic film dosimeters were prepared using nylon as substrate and pararosaniline cyanide as dye. In Co-60 gamma reference radiation field, dosimetry response performance of radiochromic film was studied and results showed that the repeatability was good to 1.0%. The response curves demonstrated good linearity in the dose range of 5-210 kGy, and the signal of radiochromic film dosimeters after irradiation under the condition of low temperature storage within 2 weeks was stable. In addition, the radiochromic film dosimeters were not found to have noticeable dose rate dependence in the range of this experiment. In the linear dose range, radiochromic film dosimeter measures the absorbed dose, with extended uncertainty 4.2% (k=2 for Co-60 gamma rays. The film was suitable as dosimeters for the parameters measurement of the electron beam on the accelerator.

  1. Measurement of MC5 antibody distribution in blood and bone marrow

    International Nuclear Information System (INIS)

    Johnson, T.K.; Gonzales, R.; Kasliwal, R.; Lear, J.; Feyerabend, A.; Ceriani, R.; Bunn, P.

    1990-01-01

    PURPOSE: Bone marrow is most often the dose-limiting organ in radioimmunotherapy. Controversy exists over optimal methods of estimating dose exposure to bone marrow. The purpose of this paper is to compare bone marrow activity from serial blood samples versus bone marrow biopsy specimens as measures of dose exposure to bone marrow. Peripheral blood samples and bone marrow biopsy specimens were obtained at 48 and 168 hours after infusion from 12 female patients infused with iodine-131-labeled MC5 antibody. The percentage of bone marrow in each biopsy specimen was assumed to be equivalent to the percentage of active bone marrow estimated to be in the pelvis. Activity present in the bone marrow as calculated with use of the estimated bone marrow mass for an adult female and then compared with the peripheral blood activity

  2. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  3. In vivo dose measurement using TLDs and MOSFET dosimeters for cardiac radiosurgery.

    Science.gov (United States)

    Gardner, Edward A; Sumanaweera, Thilaka S; Blanck, Oliver; Iwamura, Alyson K; Steel, James P; Dieterich, Sonja; Maguire, Patrick

    2012-05-10

    In vivo measurements were made of the dose delivered to animal models in an effort to develop a method for treating cardiac arrhythmia using radiation. This treatment would replace RF energy (currently used to create cardiac scar) with ionizing radiation. In the current study, the pulmonary vein ostia of animal models were irradiated with 6 MV X-rays in order to produce a scar that would block aberrant signals characteristic of atrial fibrillation. The CyberKnife radiosurgery system was used to deliver planned treatments of 20-35 Gy in a single fraction to four animals. The Synchrony system was used to track respiratory motion of the heart, while the contractile motion of the heart was untracked. The dose was measured on the epicardial surface near the right pulmonary vein and on the esophagus using surgically implanted TLD dosimeters, or in the coronary sinus using a MOSFET dosimeter placed using a catheter. The doses measured on the epicardium with TLDs averaged 5% less than predicted for those locations, while doses measured in the coronary sinus with the MOSFET sensor nearest the target averaged 6% less than the predicted dose. The measurements on the esophagus averaged 25% less than predicted. These results provide an indication of the accuracy with which the treatment planning methods accounted for the motion of the target, with its respiratory and cardiac components. This is the first report on the accuracy of CyberKnife dose delivery to cardiac targets.

  4. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A.; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M.; Dhote, Dipak S.; Deshpande, Deepak D.

    2009-01-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  5. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy.

    Science.gov (United States)

    Kinhikar, Rajesh A; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M; Dhote, Dipak S; Deshpande, Deepak D

    2009-09-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  6. Dose Titration of Pregabalin in Patients with Painful Diabetic Peripheral Neuropathy: Simulation Based on Observational Study Patients Enriched with Data from Randomized Studies.

    Science.gov (United States)

    Alexander, Joe; Edwards, Roger A; Manca, Luigi; Grugni, Roberto; Bonfanti, Gianluca; Emir, Birol; Whalen, Edward; Watt, Stephen; Parsons, Bruce

    2018-03-01

    Achieving a therapeutic response to pregabalin in patients with painful diabetic peripheral neuropathy (pDPN) requires adequate upward dose titration. Our goal was to identify relationships between titration and response to pregabalin in patients with pDPN. Data were integrated from nine randomized, placebo-controlled clinical trials as well as one 6-week open-label observational study conducted by 5808 physicians (2642 patients with pDPN) in standard outpatient settings in Germany. These studies evaluated pregabalin for treatment of pDPN. Using these data, we examined "what if" scenarios using a microsimulation platform that integrates data from randomized and observational sources as well as autoregressive-moving-average with exogenous inputs models that predict pain outcomes, taking into account weekly changes in pain, sleep interference, dose, and other patient characteristics that were unchanging. Final pain levels were significantly different depending on dose changes (P titration regardless of baseline pain severity. Altogether, 78.5% of patients with pDPN had 0-1 dose change, and 15.2% had ≥ 2 dose changes. Simulation demonstrated that the 4.8% of inadequately titrated patients who did not improve/very much improve their pain levels would have benefited from ≥ 2 dose changes. Patient satisfaction with tolerability (range 90.3-96.2%) was similar, regardless of baseline pain severity, number of titrations, or extent of improvement, suggesting that tolerability did not influence treatment response patterns. Upward dose titration reduced pain in patients with pDPN who actually received it. Simulation also predicted pain reduction in an inadequately titrated nonresponder subgroup of patients had they actually received adequate titration. The decision not to uptitrate must have been driven by factors other than tolerability. Pfizer, Inc.

  7. Minimizing and measuring lens dose when giving cranial irradiation

    International Nuclear Information System (INIS)

    Woo, S.Y.; Donaldson, S.S.; Heck, R.J.; Nielson, K.L.; Shostak, C.

    1989-01-01

    Three different techniques of administering cranial irradiation were used to determine the dose to the lens as measured in the Rando phantom. The techniques employed were as follows: (1) the central axis of the radiation beam was placed at the thickest portion of the cranium; (2) the central axis of the radiation beam was placed at the lateral orbital rim (bon canthus); (3) the central axis of the radiation beam was placed at the thickest portion of the cranium but with the beam angled 5deg posteriorly away from the eye. Thermal luminescent dosimeters (TLD) were placed in a phantom, at a point determined from a life-sized anatomical section of the plane through the midsection of the eye, to be at the location of the posterior capsule of the lens. In addition, TLDs were placed on the outer surface of the phantom head, directly lateral to the location determined to be where the lens would lie. With equally weighted lateral opposed beams, delivering a midplane dose of 200cGy, the TLDs at the point of the lens measured 21, 9.9 and 10.6% of the midplane doses from the three techniques respectively. TLDs placed directly lateral to the lens on the surface of the phantom head gave an approximation of the lens dose, particularly when techniques 2 and 3 were used. Isodose curve generated by a General Electric treatment planning computer gave lens doses similar to those of the phantom data for each of the three different radiotherapy techniques. Cranial irradiation should be carried out by either technique 2 or technique 3 to minimize radiation dose to the lens. (author). 11 refs.; 2 figs.; 3 tabs

  8. Sources of variability in OSL dose measurements using single grains of quartz

    International Nuclear Information System (INIS)

    Thomsen, K.J.; Murray, A.S.; Boetter-Jensen, L.

    2005-01-01

    In luminescence-based measurements of dose distributions in unheated mineral samples, the observed spread in dose values is usually attributed to four main factors: fluctuations in the number of photons counted, incomplete zeroing of any prior trapped charge (including signals arising from thermal transfer), heterogeneity in dosimetry, and instrument reproducibility. For correct interpretation of measured dose distributions in retrospective dosimetry, it is important to understand the relative importance of these components, and to establish whether other factors also contribute to the observed spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation was designed to deliver a uniform dose to the sample. Thus it was anticipated that statistical fluctuations in the number of photons counted and instrument reproducibility, both quantifiable entities, should be able to account for all the observed variance in the measured dose distributions. We examine this assumption in detail, and discuss the origins and importance of the residual variance in our data

  9. SU-E-T-196: Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size

    Energy Technology Data Exchange (ETDEWEB)

    Badkul, R; Nejaiman, S; Pokhrel, D; Jiang, H; Kumar, P [University of Kansas Medical Center, Kansas City, KS (United States)

    2015-06-15

    Purpose: Skin dose can be the limiting factor and fairly common reason to interrupt the treatment, especially for treating head-and-neck with Intensity-modulated-radiation-therapy(IMRT) or Volumetrically-modulated - arc-therapy (VMAT) and breast with tangentially-directed-beams. Aim of this study was to investigate accuracy of near-surface dose predicted by Eclipse treatment-planning-system (TPS) using Anisotropic-Analytic Algorithm (AAA)with varying calculation grid-size and comparing with metal-oxide-semiconductor-field-effect-transistors(MOSFETs)measurements for a range of clinical-conditions (open-field,dynamic-wedge, physical-wedge, IMRT,VMAT). Methods: QUASAR™-Body-Phantom was used in this study with oval curved-surfaces to mimic breast, chest wall and head-and-neck sites.A CT-scan was obtained with five radio-opaque markers(ROM) placed on the surface of phantom to mimic the range of incident angles for measurements and dose prediction using 2mm slice thickness.At each ROM, small structure(1mmx2mm) were contoured to obtain mean-doses from TPS.Calculations were performed for open-field,dynamic-wedge,physical-wedge,IMRT and VMAT using Varian-21EX,6&15MV photons using twogrid-sizes:2.5mm and 1mm.Calibration checks were performed to ensure that MOSFETs response were within ±5%.Surface-doses were measured at five locations and compared with TPS calculations. Results: For 6MV: 2.5mm grid-size,mean calculated doses(MCD)were higher by 10%(±7.6),10%(±7.6),20%(±8.5),40%(±7.5),30%(±6.9) and for 1mm grid-size MCD were higher by 0%(±5.7),0%(±4.2),0%(±5.5),1.2%(±5.0),1.1% (±7.8) for open-field,dynamic-wedge,physical-wedge,IMRT,VMAT respectively.For 15MV: 2.5mm grid-size,MCD were higher by 30%(±14.6),30%(±14.6),30%(±14.0),40%(±11.0),30%(±3.5)and for 1mm grid-size MCD were higher by 10% (±10.6), 10%(±9.8),10%(±8.0),30%(±7.8),10%(±3.8) for open-field, dynamic-wedge, physical-wedge, IMRT, VMAT respectively.For 6MV, 86% and 56% of all measured values

  10. Proscillaridin activity in portal and peripheral venous blood after oral administration to man

    International Nuclear Information System (INIS)

    Andersson, K.E.; Bergdahl, B.; Dencker, H.; Wettrell, G.; Linkoeping Univ.

    1977-01-01

    The absorption of proscillaridin A was studied in four patients undergoing catheterization of the portal vein for diagnostic purposes. Proscillaridin 1.5 mg was given as a single oral dose and plasma glycoside activity was analyzed by the 86 Rb-uptake inhibition technique. Proscillaridin appeared rapidly in the portal blood, peak activity being found after 15 min in three and after 30 min in one patient. In peripheral blood the peak activity occurred after approximately 35 min. Despite rapid passage across the gut wall, porto-peripheral differences in glycoside activity were small; they were zero after 4h. The mean amount absorbed as active proscillaridin during the first 4h after the dose was calculated to be only 7.1% of the given amount. Late porto-peripheral differences, probably due to enterohepatic recycling, appeared after 6h in three patients. The results suggest that proscillaridin undergoes first pass inactivation in the gut wall. Enterohepatic recirculation may contribute to the amounts of active glycoside that reach the systemic circulation. (orig.) [de

  11. Conversion of ionization measurements to radiation absorbed dose in non-water density material

    International Nuclear Information System (INIS)

    El-Khatib, E.; Connors, S.

    1992-01-01

    In bone-equivalent materials two different calculations of absorbed dose are possible: the absorbed dose to soft tissue plastic (polystyrene) within bone-equivalent material and the dose to the bone-equivalent material itself. Both can be calculated from ionization measurements in phantoms. These two calculations result in significantly different doses in a heterogeneous phantom composed of polystyrene and aluminium (a bone substitute). The dose to a thin slab of polystyrene in aluminium is much higher than the dose to the aluminium itself at the same depth in the aluminium. Monte Carlo calculations confirm that the calculation of dose to polystyrene in aluminium can be accurately carried out using existing dosimetry protocols. However, the conversion of ionization measurements to absorbed dose to high atomic number materials cannot be accurately carried out with existing protocols and appropriate conversion factors need to be determined. (author)

  12. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  13. Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Okazue, Toshiya; Kawakubo, Atsushi; Yamada, Kiyoshi; Nagata, Yasushi

    2018-04-17

    Dual-source cone-beam computed tomography (DCBCT) is currently available in the Vero4DRT image-guided radiotherapy system. We evaluated the image quality and absorbed dose for DCBCT and compared the values with those for single-source CBCT (SCBCT). Image uniformity, Hounsfield unit (HU) linearity, image contrast, and spatial resolution were evaluated using a Catphan phantom. The rotation angle for acquiring SCBCT and DCBCT images is 215° and 115°, respectively. The image uniformity was calculated using measurements obtained at the center and four peripheral positions. The HUs of seven materials inserted into the phantom were measured to evaluate HU linearity and image contrast. The Catphan phantom was scanned with a conventional CT scanner to measure the reference HU for each material. The spatial resolution was calculated using high-resolution pattern modules. Image quality was analyzed using ImageJ software ver. 1.49. The absorbed dose was measured using a 0.6-cm 3 ionization chamber with a 16-cm-diameter cylindrical phantom, at the center and four peripheral positions of the phantom, and calculated using weighted cone-beam CT dose index (CBCTDI w ). Compared with that of SCBCT, the image uniformity of DCBCT was slightly reduced. A strong linear correlation existed between the measured HU for DCBCT and the reference HU, although the linear regression slope was different from that of the reference HU. DCBCT had poorer image contrast than did SCBCT, particularly with a high-contrast material. There was no significant difference between the spatial resolutions of SCBCT and DCBCT. The absorbed dose for DCBCT was higher than that for SCBCT, because in DCBCT, the two x-ray projections overlap between 45° and 70°. We found that the image quality was poorer and the absorbed dose was higher for DCBCT than for SCBCT in the Vero4DRT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of

  14. Computed tomography dose and variability of airway dimension measurements: how low can we go?

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Long, Frederick R.; Nakano, Yasutaka

    2006-01-01

    Quantitative CT shows promise as an outcome measure for cystic fibrosis (CF) lung disease in infancy, but must be accomplished at a dose as low as reasonably achievable. To determine the feasibility of ultra-low-dose CT for quantitative measurements of airway dimensions. Two juvenile pigs were anesthetized and their lungs scanned at 25 cm H 2 O face-mask pressure in apnoea using beam currents of 5, 10, 20, 40 and 100 mAs. The lumen diameters and wall thicknesses of matched airways (n=22) at each dose were measured by two observers using validated software. Measurement variability at each dose was compared to that at 100 mAs (reference dose) for large and small airways (lumen diameter <2.5 mm). Lowering CT dose (mAs) affected measurement variability for lumen diameter of small and large airways (P<0.001) and for wall thickness of small (P<0.001), but not large (P=0.63), airways. To obtain the same measurement variability at 5 mAs as at 100 mAs, four to six small airways or one to three large airways have to be measured and averaged. Quantitative airway measurements are feasible on images obtained at as low as 5 mAs, but more airways need to be measured to compensate for greater measurement variability. (orig.)

  15. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography

    International Nuclear Information System (INIS)

    Han, S.; Lee, B.; Shin, G.; Choi, J.; Kim, J.; Park, C.; Park, H.; Lee, K.; Kim, Y.

    2008-01-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm 2 , respectively, were measured. In panoramic, cephalo-metric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm 2 (16 x 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extra-oral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extra-oral radiography. (authors)

  16. Efficient and reliable 3D dose quality assurance for IMRT by combining independent dose calculations with measurements

    International Nuclear Information System (INIS)

    Visser, R.; Wauben, D. J. L.; Godart, J.; Langendijk, J. A.; Veld, A. A. van't; Korevaar, E. W.; Groot, M. de

    2013-01-01

    Purpose: Advanced radiotherapy treatments require appropriate quality assurance (QA) to verify 3D dose distributions. Moreover, increase in patient numbers demand efficient QA-methods. In this study, a time efficient method that combines model-based QA and measurement-based QA was developed; i.e., the hybrid-QA. The purpose of this study was to determine the reliability of the model-based QA and to evaluate time efficiency of the hybrid-QA method. Methods: Accuracy of the model-based QA was determined by comparison of COMPASS calculated dose with Monte Carlo calculations for heterogeneous media. In total, 330 intensity modulated radiation therapy (IMRT) treatment plans were evaluated based on the mean gamma index (GI) with criteria of 3%/3mm and classification of PASS (GI ≤ 0.4), EVAL (0.4 0.6), and FAIL (GI ≥ 0.6). Agreement between model-based QA and measurement-based QA was determined for 48 treatment plans, and linac stability was verified for 15 months. Finally, time efficiency improvement of the hybrid-QA was quantified for four representative treatment plans. Results: COMPASS calculated dose was in agreement with Monte Carlo dose, with a maximum error of 3.2% in heterogeneous media with high density (2.4 g/cm 3 ). Hybrid-QA results for IMRT treatment plans showed an excellent PASS rate of 98% for all cases. Model-based QA was in agreement with measurement-based QA, as shown by a minimal difference in GI of 0.03 ± 0.08. Linac stability was high with an average GI of 0.28 ± 0.04. The hybrid-QA method resulted in a time efficiency improvement of 15 min per treatment plan QA compared to measurement-based QA. Conclusions: The hybrid-QA method is adequate for efficient and accurate 3D dose verification. It combines time efficiency of model-based QA with reliability of measurement-based QA and is suitable for implementation within any radiotherapy department.

  17. In vivo measurement of radiation dose during radiotherapy in breast cancer patients using MOSFET dosimeter

    International Nuclear Information System (INIS)

    Wang Lili; Tu Yu; Zhou Juying; Lu Ye; Xu Xiaoting; Li Li; Qin Songbing

    2011-01-01

    Objective: The purpose of the study was to observe and analysis the actual dosage of patients with breast cancer using metal oxide semiconductor field effect transistor (MOSFET) detector. Methods: First, Phantom measurements were performed to investigate dose distribution in the area of the junction in a half-field matching method and the influence of factors related to the accelerator. In vivo dose measurements were performed for patients with breast cancer to investigate the skin dose and the junction of supraclavicular-axillary field and tangential field in 6 MV X-ray beams. Results: Phantom measurements showed that the relative deviation in the junction were within ±3%, and the dose distributions in the junction area depended on the matching field direction (x or y). In vivo measurement of tangential region for patients showed that, the maximum dose deviation between measurement and calculation was -30.39%,the minimum deviation was -18.85%, the average dose deviation was -24.76%. The dose deviation of tangential fields for patients with breast-conserving surgery was larger than that patients with radical surgery (t =2.40, P<0.05), while dose deviation of supraclavicular-axillary fields was not significantly different. The average values of 15 fraction in the junction area showed more stable than one individual measurement. Conclusions: It is important to real-time, in vivo measurement of radiation dose during radiotherapy in patients with breast cancer, and change treatment plan in time, to ensure the accuracy of target dose. (authors)

  18. Dose Measurements in a 20-J Repetitive Plasma Focus

    Science.gov (United States)

    Goudarzi, S.; Babaee, H.; Esmaeli, A.; Nasiri, A.; Mazandarani, A.

    2018-02-01

    In this article, the results of X-ray dose measurements executed using thermoluminescent dosimeters in experiments with a very small (20 J) repetitive plasma focus device named SORENA-1 are presented and analyzed. The working gas in these experiments was Argon. Also, pinch formation in experiments with this device has been observed. This device has been designed and constructed in Plasma and Nuclear Fusion Research School of Nuclear Science and Technology Research Institute of Iran. From these results, it is concluded that we can do experiments with this device using Ar as working gas all over the working days of year, and a good symmetry for measured dose around the device has been seen.

  19. Eye lens dosimetry for interventional procedures – Relation between the absorbed dose to the lens and dose at measurement positions

    International Nuclear Information System (INIS)

    Geber, Therese; Gunnarsson, Mikael; Mattsson, Sören

    2011-01-01

    This study investigated the relationship between the absorbed dose to the lens of the eye and the absorbed dose at different measurement positions near the eye of interventional radiologists. It also visualised the dose distribution inside the head, both when protective eyewear were used and without such protection. The best position for an eye lens dosimeter was found to be at the side of the head nearest to the radiation source, close to the eye. Positioning the dosimeter at the eyebrow could lead to an underestimation of the lens dose of as much as 45%. The measured dose distribution showed that the absorbed dose to the eye lenses was high compared to the other parts of the head, which stresses the importance of wearing protective eyewear. However, many models of eyewear were found to be deficient as the radiation could slip through at several places, e.g. at the cheek. The relationship between the absorbed dose to the lens and the kerma-area-product (P KA ) delivered to the patient was also studied.

  20. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    ICRP introduced the concept of Effective Dose Equivalent H(sub)E and fixed the basic limits of radiation exposure in terms of H(sub)I. As H(sub)E cannot be measured, ICRP stated that with external exposure to penetrating radiation the limitation of the Dose Equivalent Index H(sub)I would afford at least as good a level of protection. However, difficulties arise in measuring H(sub)I and in calibrating instruments in terms of H(sub)I, since the height and location of the dose equivalent maximum in the sphere which is the phantom used in the definition of H(sub)I, depend on the energy and the angular distribution of the incident radiation. That is, H(sub)I is not an additive quantity relative to the partial H(sub)I(sub)i-values of the different energy and angular components. Hence, 1) the distribution of dose equivalent in the sphere must be measured in full for a determination of H(sub)I, and 2) it is not possible to calibrate an instrument which does not exhibit the scattering and absorption properties of the sphere, consistently for arbitrary radiation fields in terms of H(sub)I. Thus the calibration in an unidirectional beam would infer an uncertainty which may amount to a factor of up to 4. This would hardly be tolerable as a base for radiation protection provisions. An alternative is to introduce operational quantities which are additive, e.g. 1) the sum of maxima of the dose equivalent distributions in the sphere produced by different radiation components, and 2) the mean dose equivalent in the sphere. Their relation to H(sub)E for different types of radiation and consequences on secondary limits are discussed. (H.K.)

  1. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose- effect curve)

    International Nuclear Information System (INIS)

    Al Achkar, W.

    2002-01-01

    In order to draw a dose-effect curve, blood from eight healthy people were studied. Samples were irradiated in tubes with 0.15-2.5 gray of gamma ray.Irradiated and control samples were incubated for cell cultures. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics+ rings and total numbers of breaks were drawn. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  2. Routine measurement of dose to the bladder: still an utopy?

    International Nuclear Information System (INIS)

    Schaeken, B.; Goor, C.; Weyngaert, D. van den; Middelheim, A.Z.

    1996-01-01

    Dosimetry with alanine is based on the relative and non destructive measurement of stable free radicals produced by radiation. The flexibility of the method (linear dose response, no energy dependence, no dose rate dependence) as well as in detector design makes this method very suited as in vivo dosimetry system for brachytherapy. Absorbed dose to the detector is measured as the signal intensity of the central line of the electron paramagnetic resonance (EPR) powder spectrum of alanine. The dose at the bladder reference point (ICRU 38) can be measured with no additional inconvenience to the patient using a liquid alanine detector (natural oil with alanine crystals of size less than 200 mm) as follows: the balloon of the Foley catheter is filled with ± 7 cc of liquid detector instead of a radio-opaque fluid. By sedimentation the alanine crystals are collected at the posterior surface of the balloon in the vicinity of the bladder reference point. After the treatment the detector is recuperated from the Foley catheter and read out using a small quartz tube. In vitro measurements revealed 1) a perfect linear dose response in the range between 2 Gy and 5 Gy; 2) highly reproducible measurements: 3% (1s) at 1 Gy, 0.3% (1s) at 50 Gy; 3) a minor quantity of oil is leaking through the balloon wall which we expect is of no harm to the patient; 4) retrieving the irradiated alanine crystals from the Foley catheter reduces the EPR signal with a factor 0.927 ± 0.003 (1s); 5) subsequent mixing followed by centrifuge of the detector fluid will result in an EPR signal stable within ± 1% (1s); 6) the detector fluid shows an excellent EPR stability in a period of months after irradiation. We only recently obtained permission of the ethical committee to use this technique in vivo; the results of at least one patient will be discussed

  3. Gamma irradiator dose mapping: a Monte Carlo simulation and experimental measurements

    International Nuclear Information System (INIS)

    Rodrigues, Rogerio R.; Ribeiro, Mariana A.; Grynberg, Suely E.; Ferreira, Andrea V.; Meira-Belo, Luiz Claudio; Sousa, Romulo V.; Sebastiao, Rita de C.O.

    2009-01-01

    Gamma irradiator facilities can be used in a wide range of applications such as biological and chemical researches, food treatment and sterilization of medical devices and products. Dose mapping must be performed in these equipment in order to establish plant operational parameters, as dose uniformity, source utilization efficiency and maximum and minimum dose positions. The isodoses curves are generally measured using dosimeters distributed throughout the device, and this procedure often consume a large amount of dosimeters, irradiation time and manpower. However, a detailed curve doses identification of the irradiation facility can be performed using Monte Carlo simulation, which reduces significantly the monitoring with dosimeters. The present work evaluates the absorbed dose in the CDTN/CNEN Gammacell Irradiation Facility, using the Monte Carlo N-particles (MCNP) code. The Gammacell 220, serial number 39, was produced by Atomic Energy of Canada Limited and was loaded with sources of 60 Co. Dose measurements using TLD and Fricke dosimeters were also performed to validate the calculations. The good agreement of the results shows that Monte Carlo simulations can be used as a predictive tool of irradiation planning for the CDTN/CNEN Gamma Cell Irradiator. (author)

  4. Retrospective Correction of Physiological Noise in DTI Using an Extended Tensor Model and Peripheral Measurements

    Science.gov (United States)

    Mohammadi, Siawoosh; Hutton, Chloe; Nagy, Zoltan; Josephs, Oliver; Weiskopf, Nikolaus

    2013-01-01

    Diffusion tensor imaging is widely used in research and clinical applications, but this modality is highly sensitive to artefacts. We developed an easy-to-implement extension of the original diffusion tensor model to account for physiological noise in diffusion tensor imaging using measures of peripheral physiology (pulse and respiration), the so-called extended tensor model. Within the framework of the extended tensor model two types of regressors, which respectively modeled small (linear) and strong (nonlinear) variations in the diffusion signal, were derived from peripheral measures. We tested the performance of four extended tensor models with different physiological noise regressors on nongated and gated diffusion tensor imaging data, and compared it to an established data-driven robust fitting method. In the brainstem and cerebellum the extended tensor models reduced the noise in the tensor-fit by up to 23% in accordance with previous studies on physiological noise. The extended tensor model addresses both large-amplitude outliers and small-amplitude signal-changes. The framework of the extended tensor model also facilitates further investigation into physiological noise in diffusion tensor imaging. The proposed extended tensor model can be readily combined with other artefact correction methods such as robust fitting and eddy current correction. PMID:22936599

  5. The precision of radiotherapy in Gliwice, Poland, estimated by in vivo dose measurements

    International Nuclear Information System (INIS)

    Orlef, A.; Lobodziec, W.; Maniakowski, Z.

    1995-01-01

    The aim of this work was to evaluate the precision of irradiation using gamma Co-60 Philips Unites and linear accelerators Neptun 10p and Saturne II+ which generate X-rays of 9MV and 23MV respectively. This work has been undertaken for the reason that the effect of radiotherapy of cancer is strongly dependent of the precision of the dose delivery to a patient. The in vivo dose measurements were performed using a p-type silicon diodes (EDE-5, EDP-20, EDP-30) connected to a DPD-510 electrometer (Scanditronix). The diodes were calibrated by comparison their response to a 0.6cm 3 ionization chamber (NE 2571) placed at the relevant depth in the phantom. The entrance and exit dose calibration factors have been determined for reference conditions (constant SSD, field, temperature, ...). For conditions different from reference one the correction factors have been evaluated. The 855 in vivo dose measurements of entrance dose were performed. The histograms of percentage differences between measured and planed entrance dose has been constructed and analyzed. The average values of such differences were: -1.3%, 4.0%, -0.9% for gamma Co-60, X 9MV, X 23MV, respectively. These values can be interpreted as systematic uncertainties. The standard deviations (SD) were found as: 3.1%, 4.1%, 3.5%. These parameters can be considered as a random uncertainties. The 546 cases of dose at the reference point for head and neck cancer have been evaluated taking into account the entrance and exit measured doses. The average difference between those values and planned one was 1.3% and SD = 5.1%. There were observed the changes of the dimensions of the irradiated tissue block during the radiotherapy. This had a significant influence on the differences between delivered (measured) and planed doses at reference point

  6. Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

    Science.gov (United States)

    Yoon, Jihyung; Heins, David; Zhao, Xiaodong; Sanders, Mary; Zhang, Rui

    2017-12-01

    More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K OBOF and in-beam out-of-field (IBOF) correction factor K IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy-1 for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.

  7. Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tagliafico, Alberto [University of Genoa, Institute of Anatomy, Department of Experimental Medicine, Genoa (Italy); Bignotti, Bianca; Martinoli, Carlo [University of Genoa, Radiology Department, Genoa, Genova (Italy); Tagliafico, Giulio [CNR-IMATI, Consiglio Nazionale delle Ricerche, Istituto di Matematica Applicata e Tecnologie Informatiche, Genova (Italy)

    2015-05-01

    To prospectively evaluate the precision and reproducibility of T2*-derived measurements of the peripheral nerves. The study was approved by the local ethics committee and written informed consent was obtained. Bilateral upper and lower limb MRI examination was performed in 40 healthy subjects on a 3.0-T scanner. MRI protocol included T1-turbo spin-echo, T2-turbo spin-echo with fat suppression, and multiecho gradient recalled echo. Measurements of T2* times on T2* maps at different anatomical levels were performed. Three authors measured independently and in different sessions at baseline and after 4 weeks. Non-parametric tests and Bland-Altman statistics were used. Minimum and maximum percentage variability were 10 % and 19 % for T2* (84-91 % of reproducibility). Maximum values of minimum detectable differences between limbs was 16 % (with 95 % CI: 2-37). Intra- and inter-observer agreement of the three radiologists for T2* was considered good. Evaluating the combined influence of the observer and of the repeated measurements the reproducibility was 87-98 %. T2* measurement of the peripheral nerves is precise and reproducible. The healthy contralateral side can be used as an internal control. Variations in T2* values up to 16 % have to be considered. (orig.)

  8. Gene expression in human peripheral blood 48 hours after exposure to ionizing radiation

    Data.gov (United States)

    National Aeronautics and Space Administration — Analysis of human peripheral blood 48 hours after irradiation ex vivo with graded doses of gamma rays. Results have been used in building and testing classifiers to...

  9. Measurement of wavefront aberrations in cortex and peripheral nerve using a two-photon excitation guidestar

    Science.gov (United States)

    Futia, Gregory L.; Fontaine, Arjun; McCullough, Connor; Ozbay, Baris N.; George, Nickolas M.; Caldwell, John; Restrepo, Diego; Weir, Richard; Gibson, Emily A.

    2018-02-01

    Neural-machine interfaces using optogenetics are of interest due to their minimal invasiveness and potential for parallel read in and read out of activity. One possible biological target for such an interface is the peripheral nerve, where axonlevel imaging or stimulation could greatly improve interfacing with artificial limbs or enable neuron/fascicle level neuromodulation in the vagus nerve. Two-photon imaging has been successful in imaging brain activity using genetically encoded calcium or voltage indicators, but in the peripheral nerve, this is severely limited by scattering and aberrations from myelin. We employ a Shack-Hartman wavefront sensor and two-photon excitation guidestar to quantify optical scattering and aberrations in peripheral nerves and cortex. The sciatic and vagus nerves, and cortex from a ChAT-Cre ChR-eYFP transgenic mouse were excised and imaged directly. In peripheral nerves, defocus was the strongest aberration followed by astigmatism and coma. Peripheral nerve had orders of magnitude higher aberration compared with cortex. These results point to the potential of adaptive optics for increasing the depth of two-photon access into peripheral nerves.

  10. A simplified approach for exit dose in vivo measurements in radiotherapy and its clinical application

    International Nuclear Information System (INIS)

    Banjade, D.P.; Shukri, A.; Tajuddin, A.A.; Shrestha, S.L.; Bhat, M.

    2002-01-01

    This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within ±3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10.9 to 14.0% compared to the dose derived from theoretical estimation (normalized dose at d max ). The same measurements for 10 MV beams are lowered by 9.0 to 13.5%. The variations of measured exit dose for different field sizes are found to be within 2.5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1.5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors' viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated for in vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice. Copyright (2002) Australasian College of Physical Scientists and Engineers in Medicine

  11. Absolute dose measurement Gafchromic R EBT2 movies. Case Study of Kaposis sarcoma

    International Nuclear Information System (INIS)

    Pereira, L.; Moral, F. del; Meilan, E.; Azevedo Gomes, J. C. de; Tejeiro Garcia, A. G.; Andrade Alvarez, B.; Vazquez, J.; Nieto, I.; Medal, D.; Lopez Medina, A.; Francisco, S.; Salgado, M.; Munoz, V.

    2011-01-01

    Because of its high spatial resolution, low energy dependence and good response over a wide energy range, EBT2 Gafchromic films are widely used in many applications in radiotherapy for measuring relative dose. Despite being the most common use can be used to measure absolute dose. This text is an example of using films as EBT2 for in vivo absolute dose in a Kaposis sarcoma.

  12. Monte Carlo-based dose reconstruction in a rat model for scattered ionizing radiation investigations.

    Science.gov (United States)

    Kirkby, Charles; Ghasroddashti, Esmaeel; Kovalchuk, Anna; Kolb, Bryan; Kovalchuk, Olga

    2013-09-01

    In radiation biology, rats are often irradiated, but the precise dose distributions are often lacking, particularly in areas that receive scatter radiation. We used a non-dedicated set of resources to calculate detailed dose distributions, including doses to peripheral organs well outside of the primary field, in common rat exposure settings. We conducted a detailed dose reconstruction in a rat through an analog to the conventional human treatment planning process. The process consisted of: (i) Characterizing source properties of an X-ray irradiator system, (ii) acquiring a computed tomography (CT) scan of a rat model, and (iii) using a Monte Carlo (MC) dose calculation engine to generate the dose distribution within the rat model. We considered cranial and liver irradiation scenarios where the rest of the body was protected by a lead shield. Organs of interest were the brain, liver and gonads. The study also included paired scenarios where the dose to adjacent, shielded rats was determined as a potential control for analysis of bystander effects. We established the precise doses and dose distributions delivered to the peripheral organs in single and paired rats. Mean doses to non-targeted organs in irradiated rats ranged from 0.03-0.1% of the reference platform dose. Mean doses to the adjacent rat peripheral organs were consistent to within 10% those of the directly irradiated rat. This work provided details of dose distributions in rat models under common irradiation conditions and established an effective scenario for delivering only scattered radiation consistent with that in a directly irradiated rat.

  13. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  14. Radiation-induced rib fracture after stereotactic body radiotherapy with a total dose of 54–56 Gy given in 9–7 fractions for patients with peripheral lung tumor: impact of maximum dose and fraction size

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Sato, Mariko; Hirose, Katsumi; Akimoto, Hiroyoshi; Kawaguchi, Hideo; Hatayama, Yoshiomi; Ono, Shuichi; Takai, Yoshihiro

    2015-01-01

    Radiation-induced rib fracture after stereotactic body radiotherapy (SBRT) for lung cancer has been recently reported. However, incidence of radiation-induced rib fracture after SBRT using moderate fraction sizes with a long-term follow-up time are not clarified. We examined incidence and risk factors of radiation-induced rib fracture after SBRT using moderate fraction sizes for the patients with peripherally located lung tumor. During 2003–2008, 41 patients with 42 lung tumors were treated with SBRT to 54–56 Gy in 9–7 fractions. The endpoint in the study was radiation-induced rib fracture detected by CT scan after the treatment. All ribs where the irradiated doses were more than 80% of prescribed dose were selected and contoured to build the dose-volume histograms (DVHs). Comparisons of the several factors obtained from the DVHs and the probabilities of rib fracture calculated by Kaplan-Meier method were performed in the study. Median follow-up time was 68 months. Among 75 contoured ribs, 23 rib fractures were observed in 34% of the patients during 16–48 months after SBRT, however, no patients complained of chest wall pain. The 4-year probabilities of rib fracture for maximum dose of ribs (Dmax) more than and less than 54 Gy were 47.7% and 12.9% (p = 0.0184), and for fraction size of 6, 7 and 8 Gy were 19.5%, 31.2% and 55.7% (p = 0.0458), respectively. Other factors, such as D2cc, mean dose of ribs, V10–55, age, sex, and planning target volume were not significantly different. The doses and fractionations used in this study resulted in no clinically significant rib fractures for this population, but that higher Dmax and dose per fraction treatments resulted in an increase in asymptomatic grade 1 rib fractures

  15. A phantom based method for deriving typical patient doses from measurements of dose-area product on populations of patients

    International Nuclear Information System (INIS)

    Chapple, C.-L.; Broadhead, D.A.

    1995-01-01

    One of the chief sources of uncertainty in the comparison of patient dosimetry data is the influence of patient size on dose. Dose has been shown to relate closely to the equivalent diameter of the patient. This concept has been used to derive a prospective, phantom based method for determining size correction factors for measurements of dose-area product. The derivation of the size correction factor has been demonstrated mathematically, and the appropriate factor determined for a number of different X-ray sets. The use of phantom measurements enables the effect of patient size to be isolated from other factors influencing patient dose. The derived factors agree well with those determined retrospectively from patient dose survey data. Size correction factors have been applied to the results of a large scale patient dose survey, and this approach has been compared with the method of selecting patients according to their weight. For large samples of data, mean dose-area product values are independent of the analysis method used. The chief advantage of using size correction factors is that it allows all patient data to be included in a survey, whereas patient selection has been shown to exclude approximately half of all patients. (author)

  16. Repair of changes in peripheral blood count of rats after chronic irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Chlebovsky, O; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes are described in the peripheral blood count of rats irradiated during 120 days with doses of 95.7, 191.4, 258.4, 344.5 and 507.2 mGy/day; during 15 days with a dose of 1004.8 mGy and examined till the 180th day after termination of irradiation. The course of repair can be divided into two phases, namely: phase 1 till the 40th day after termination of irradiation when leukocyte and platelet counts reach approximately 50% of control values; this phase lasts until the 100th day after cessation of irradiation; phase 2 from the 100th till the 180th day when these peripheral blood element counts attain the level of control values. Thus in the stated conditions of irradiation, 150 to 180 days are required for radiation damage to the hemopoietic system to repair.

  17. Toxicity After Central versus Peripheral Lung Stereotactic Body Radiation Therapy: A Propensity Score Matched-Pair Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mangona, Victor S. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Aneese, Andrew M. [Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Marina, Ovidiu; Hymas, Richard V. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Ionascu, Dan; Robertson, John M. [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Gallardo, Lori J. [Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States); Department of Radiology, Beaumont Health System, Royal Oak, Michigan (United States); Grills, Inga Siiner, E-mail: igrills@beaumont.edu [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Oakland University William Beaumont School of Medicine, Rochester, Michigan (United States)

    2015-01-01

    Purpose: To compare toxicity after stereotactic body radiation therapy (SBRT) for “central” tumors—within 2 cm of the proximal bronchial tree or with planning tumor volume (PTV) touching mediastinum—versus noncentral (“peripheral”) lung tumors. Methods and Materials: From November 2005 to January 2011, 229 tumors (110 central, 119 peripheral; T1-3N0M0 non–small-cell lung cancer and limited lung metastases) in 196 consecutive patients followed prospectively at a single institution received moderate-dose SBRT (48-60 Gy in 4-5 fractions [biologic effective dose=100-132 Gy, α/β=10]) using 4-dimensional planning, online image-guided radiation therapy, and institutional dose constraints. Clinical adverse events (AEs) were graded prospectively at clinical and radiographic follow-up using Common Terminology Criteria for Adverse Events version 3.0. Pulmonary function test (PFT) decline was graded as 2 (25%-49.9% decline), 3 (50.0%-74.9% decline), or 4 (≥75.0% decline). Central/peripheral location was assessed retrospectively on planning CT scans. Groups were compared after propensity score matching. Characteristics were compared with χ{sup 2} and 2-tailed t tests, adverse events with χ{sup 2} test-for-trend, and cumulative incidence using competing risks analysis (Gray's test). Results: With 79 central and 79 peripheral tumors matched, no differences in AEs were observed after 17 months median follow-up. Two-year cumulative incidences of grade ≥2 pain, musculoskeletal, pulmonary, and skin AEs were 14%, 5%, 6%, and 10% (central) versus 19%, 10%, 10%, and 3% (peripheral), respectively (P=.31, .38, .70, and .09). Grade ≥2 cardiovascular, gastrointestinal, and central nervous system AEs were rare (<1%). Two-year incidences of grade ≥2 clinical AEs (28% vs 25%, P=.79), grade ≥2 PFT decline (36% vs 34%, P=.94), grade ≥3 clinical AEs (3% vs 7%, P=.48), and grade ≥3 PFT decline (0 vs 10%, P=.11) were similar for central versus peripheral

  18. Oxidative stress and nerve damage: Role in chemotherapy induced peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Aparna Areti

    2014-01-01

    Full Text Available Peripheral neuropathy is a severe dose limiting toxicity associated with cancer chemotherapy. Ever since it was identified, the clear pathological mechanisms underlying chemotherapy induced peripheral neuropathy (CIPN remain sparse and considerable involvement of oxidative stress and neuroinflammation has been realized recently. Despite the empirical use of antioxidants in the therapy of CIPN, the oxidative stress mediated neuronal damage in peripheral neuropathy is still debatable. The current review focuses on nerve damage due to oxidative stress and mitochondrial dysfunction as key pathogenic mechanisms involved in CIPN. Oxidative stress as a central mediator of apoptosis, neuroinflammation, metabolic disturbances and bioenergetic failure in neurons has been highlighted in this review along with a summary of research on dietary antioxidants and other nutraceuticals which have undergone prospective controlled clinical trials in patients undergoing chemotherapy.

  19. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  20. Biophysical dose measurement using electron paramagnetic resonance in rodent teeth

    International Nuclear Information System (INIS)

    Khan, R.F.H.; Rink, W.J.; Boreham, D.R.

    2003-01-01

    Electron paramagnetic resonance (EPR) dosimetry of human tooth enamel has been widely used in measuring radiation doses in various scenarios. However, there are situations that do not involve a human victim (e.g. tests for suspected environmental overexposures, measurements of doses to experimental animals in radiation biology research, or chronology of archaeological deposits). For such cases we have developed an EPR dosimetry technique making use of enamel of teeth extracted from mice. Tooth enamel from both previously irradiated and unirradiated mice was extracted and cleaned by processing in supersaturated KOH aqueous solution. Teeth from mice with no previous irradiation history exhibited a linear EPR response to the dose in the range from 0.8 to 5.5 Gy. The EPR dose reconstruction for a preliminarily irradiated batch resulted in the radiation dose of (1.4±0.2) Gy, which was in a good agreement with the estimated exposure of the teeth. The sensitivity of the EPR response of mouse enamel to gamma radiation was found to be half of that of human tooth enamel. The dosimetric EPR signal of mouse enamel is stable up at least to 42 days after exposure to radiation. Dose reconstruction was only possible with the enamel extracted from molars and premolars and could not be performed with incisors. Electron micrographs showed structural variations in the incisor enamel, possibly explaining the large interfering signal in the non-molar teeth

  1. Challenges Evaluating Chemotherapy-Induced Peripheral Neuropathy in Childhood Cancer Survivors.

    Science.gov (United States)

    Mohrmann, Caroline; Armer, Jane; Hayashi, Robert J

    Children treated for cancer are exposed to a variety of chemotherapeutic agents with known toxicity to the peripheral nervous system. The side effect of peripheral neuropathy can cause changes in sensation, function, and even cause pain. Although peripheral neuropathy is recognized by pediatric oncology nurses as an important and significant side effect, measuring neuropathy can be quite complex for clinical care and research efforts. With more children surviving a cancer diagnosis today, this issue is increasingly important for childhood cancer survivors. This article has reviewed existing literature examining peripheral neuropathy in childhood cancer survivors with particular interest paid to measurement tools available and needs for future research. It is important for nurses to choose appropriate measures for clinical care and research methods in order to have an impact on patients experiencing this condition.

  2. Modification of hemoglobin level and hematocrit value in the peripheral blood of mice after 45Ca internal irradiation by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Bhagat, R.M.; Kumar, A.

    1986-01-01

    Radioprotective effect of MPG has been studied on the hemoglobin level and hematocrit value of peripheral blood of Swiss albino mice against radiation-induced changes after injecting radiocalcium ( 45 Ca) at the dose level of 37 kBq/g body weight. MPG was injected 15-30 minutes before 45 Ca injection at dose of 20 mg/kg body weight intraperitoneally and also MPG was injected at various repeated doses. It has been observed that MPG in repeated doses is effective in reducing the radiation-induced changes in the hemoglobin and hematocrit value of peripheral blood of Swiss albino mice following 45 Ca internal irradiation. (author)

  3. Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

    International Nuclear Information System (INIS)

    Pfob, H.; Heinemann, G.

    1992-01-01

    Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

  4. Use of betahistine in the treatment of peripheral vertigo.

    Science.gov (United States)

    Ramos Alcocer, Rubén; Ledezma Rodríguez, José Gregorio; Navas Romero, Antonio; Cardenas Nuñez, José Luis; Rodríguez Montoya, Vicente; Deschamps, Jose Junior; Liviac Ticse, Jorge Anibal

    2015-01-01

    Clinical studies and meta-analyses demonstrated that betahistine is effective and safe in the treatment of Ménière's disease, BPPV (benign paroxysmal positional vertigo), vestibular neuronitis, and other types of peripheral vertigo. The goal of this paper is to review the pharmacological profile of betahistine and the evidence for its effectiveness and safety in the treatment of peripheral vertigo. Selection criteria for the publications on betahistine included randomized clinical trials that evaluated the effectiveness and safety of betahistine vs placebo or active control in the treatment of peripheral vertigo. Recent meta-analyses were also included. Databases searched included PubMed, the Cochrane Ear, Nose and Throat Disorders Group Trials Register, and ICTRP. The review also presents an update on the mechanisms of action, pharmacodynamics, and pharmacokinetics of betahistine. Efficacy and safety of betahistine has been demonstrated in numerous clinical trials. The precise mechanism of action of betahistine is still not completely understood, but the clinical experience demonstrated the benefit of betahistine in different types of peripheral vertigo. In more than 40 years of clinical use, betahistine has shown an excellent safety profile with the usual dose range from 8-48 mg daily. According to clinical studies, betahistine 48 mg daily during 3 months is an effective and safe option for the treatment of peripheral vertigo.

  5. Radiation doses measured by TLD (thermo luminescent dosimeter) in x-ray examination

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hiraki, Motoji; Murakami, Shozo; Nishikawa, Naozo; Yagi, Takayuki

    1977-01-01

    By means of TLD, we measured the radiation doses to the skin in the central area of the field of radiation and doses scattered outside of the radiation field, utilizing a phantom to define a suitable radiation field. Clinically, when radiography of the gall bladder and the chest was done, we measured both the radiation doses of the central skin area where radiation was done and the skin above the area of the female gonads. In radiography of the chest, the radiation doses to the skin area above the female gonads situate was under 0.1 mR. When female gonads are less than 15 cm from the margin of the radiation field of the radiation dose can be decreased by 30% if gum sheets containing lead are used to cover the skin area outside the radiation field. (auth.)

  6. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    Science.gov (United States)

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in

  7. Characterization of MOSFET dosimeters for low‐dose measurements in maxillofacial anthropomorphic phantoms

    Science.gov (United States)

    Wolff, Jan E.; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-01-01

    The aims of this study were to characterize reinforced metal‐oxide‐semiconductor field‐effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low‐dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50–90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point‐dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k=2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low‐dose limit. The sensitivity was 3.09±0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was −8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD‐comparable low‐dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However

  8. Gene expression dose-response changes in microarrays after exposure of human peripheral lung epithelial cells to nickel(II).

    Science.gov (United States)

    Cheng, Robert Y S; Zhao, Ailian; Alvord, W Gregory; Powell, Douglas A; Bare, Robert M; Masuda, Akira; Takahashi, Takashi; Anderson, Lucy M; Kasprzak, Kazimierz S

    2003-08-15

    Occupational exposure to nickel compounds is associated with lung cancer risk; both genotoxic and epigenetic mechanisms have been proposed. For comprehensive examination of the acute effects of nickel(II) acetate on gene expression in cultured human peripheral lung epithelial HPL1D cells, microarray analyses were carried out with cDNA chips (approximately 8000 cDNAs). Cells were exposed for 24 h to nontoxic (50, 100, and 200 microM) or toxic (400, 800, and 1600 microM) nickel(II) concentrations. Cluster analysis was applied to the 868 genes with > or = 2-fold change at any concentration. Two main clusters showed marked up- or down-regulation at the highest, toxic concentrations. The data further subdivided into 10 highly cohesive clusters with high probability, and of these only 2 had the same response trend at low nontoxic as at high concentrations, an observation of clear relevance to the process of high- to low-dose extrapolation in risk assessment. There were 113 genes showing > or = 2-fold change at the three lower nontoxic concentrations, those most relevant to in vivo carcinogenesis. In addition to expected responses of metallothionein, ferritin, and heat-shock proteins, the results revealed for the first time changed expression of some potential cancer-related genes in response to low-dose Ni(II): RhoA, dyskerin, interferon regulatory factor 1, RAD21 homologue, and tumor protein, translationally controlled. Overall, most of the genes impacted by nontoxic concentrations of nickel(II) acetate related to gene transcription, protein synthesis and stability, cytoskeleton, signaling, metabolism, cell membrane, and extracellular matrix.

  9. Measurement of Patient Dose from Computed Tomography Using Physical Anthropomorphic Phantom

    International Nuclear Information System (INIS)

    Jang, Ki Won; Lee, Jae Ki; Kim, Jong Kyung

    2005-01-01

    The computed tomography (CT) provides a high quality in images of human body but contributes relatively high patient dose compared with the conventional X-ray examination. Furthermore, the frequency of CT examination has been increasing in Korea for the last decade owing to the national health insurance benefits. Increasing concerns about high patient dose from CT have stimulated a great deal of researches on dose assessment, which many of these are based on the Monte Carlo simulation. But in this study, absorbed doses and effective dose of patient undergoing CT examination were determined experimentally using anthropomorphic physical phantom and the measured results are compared with those from Monte Carlo calculation

  10. The estimation of effective doses using measurement of several relevant physical parameters from radon exposures

    International Nuclear Information System (INIS)

    Ridzikova, A; Fronka, A.; Maly, B.; Moucka, L.

    2003-01-01

    In the present investigation, we will be study the dose relevant factors from continual monitoring in real homes into account getting more accurate estimation of 222 Rn the effective dose. The dose relevant parameters include the radon concentration, the equilibrium factor (f), the fraction (fp) of unattached radon decay products and real time occupancy people in home. The result of the measurement are the time courses of radon concentration that are based on estimation effective doses together with assessment of the real time occupancy people indoor. We found out by analysis that year effective dose is lower than effective dose estimated by ICRP recommendation from the integral measurement that included only average radon concentration. Our analysis of estimation effective doses using measurement of several physical parameters was made only in one case and for the better specification is important to measure in different real occupancy houses. (authors)

  11. Collective dose as a performance measure for occupational radiation protection programs: Issues and recommendations

    International Nuclear Information System (INIS)

    Strom, D.J.; Harty, R.; Hickey, E.E.; Martin, J.B.; Peffers, M.S.; Kathren, R.L.

    1998-07-01

    Collective dose is one of the performance measures used at many US Department of Energy (DOE) contractor facilities to quantitatively assess the objectives of the radiation protection program. It can also be used as a management tool to improve the program for keeping worker doses as low as reasonably achievable (ALARA). Collective dose is used here to mean the sum of all total effective dose equivalent values for all workers in a specified group over a specified time. It is often used as a surrogate estimate of radiological risk. In principle, improvements in radiation protection programs and procedures will result in reduction of collective dose, all other things being equal. Within the DOE, most frequently, a single collective dose number, which may or may not be adjusted for workload and other factors, is used as a performance measure for a contractor. The purpose of this report is to evaluate the use of collective dose as a performance measure for ALARA programs at DOE sites

  12. Comparison and analysis of BNCT radiation dose between gold wire and JCDS measurement

    International Nuclear Information System (INIS)

    Kageji, T.; Mizobuchi, Y.; Nagahiro, S.; Nakagawa, Y.; Kumada, Hiroaki

    2006-01-01

    We compared and evaluated boron neutron capture therapy (BNCT) radiation dose between gold wire measurement and JAERI Computational Dosimetry System (JCDS). Gold wire analysis demonstrates the actual BNCT dose though it dose not reflect the real the maximum and minimum dose in tumor tissue. We can conclude that JCDS is precise and high-reliable dose planning system for BNCT. (author)

  13. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-07

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients' CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  14. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-01

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  15. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    Science.gov (United States)

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  16. A content analysis of peripheral arterial disease patient-reported outcome measures using the International Classification of Functioning, Disability and Health.

    Science.gov (United States)

    Osborne, Candice Lee; Kauvar, David Seth

    2017-10-17

    The purpose of this study was to link, classify and describe the content of peripheral arterial disease (PAD)-specific patient-reported outcome measures using the International Classification of Functioning. The results were then analyzed to determine if these assessments provide clinicians and researchers with a comprehensive understanding of the lived experience of patients with PAD. Each meaningful concept in identified PAD assessments was linked to the International Classification of Functioning, Disability and Health to determine included and excluded content areas. An overall perspective was assigned to each assessment item. Inter-rater reliability was established using a kappa statistic. The body functions component is most frequently addressed overall followed by the activities and participation component. International Classification of Functioning chapter and category distribution vary greatly between assessments and no assessment comprehensively examines community participation and relationships. The majority of the assessment items are of the health status-disability and quality of life perspectives. The results of this study suggest the need for the development of a comprehensive PAD assessment that includes a more even distribution of International Classification of Functioning topics and subtopics. A more comprehensive assessment would better capture the lived experience of this patient population. Implications for Rehabilitation A better understanding of the data collected using the current peripheral arterial disease-specific patient-reported outcome measures may contribute to the development of more comprehensive assessment tools that will ultimately lead to improved patient care. This study contributes to the preliminary foundation for the development of a peripheral arterial disease International Classification of Functioning, Disability and Health Core Set. Clinicians and researchers interested in using peripheral arterial disease

  17. The radiation dose from a proposed measurement of arsenic and selenium in human skin

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R; Mader, Joanna E; Fleming, David E B, E-mail: mgherase@mta.c [Department of Physics, Mount Allison University, 67 York Street, Sackville, NB E4L 1E6 (Canada)

    2010-09-21

    Dose measurements following 10 min irradiations with a portable x-ray fluorescence spectrometer composed of a miniature x-ray tube and a silicon PiN diode detector were performed using thermoluminescent dosimeters consisting of LiF:Mg,Ti chips of 3 mm diameter and 0.4 mm thickness. The table-top setup of the spectrometer was used for all measurements. The setup included a stainless steel lid which served as a radiation shield. Two rectangular polyethylene skin/soft tissue phantoms with two cylindrical plaster of Paris bone phantoms were used to study the effect of x-ray beam attenuation and backscatter on the measured dose. Eight different irradiation experiments were performed. The average dose rate values measured with TLD chips within a 1 x 1 cm{sup 2} area were between 4.8 and 12.8 mGy min{sup -1}. The equivalent dose for a 1 x 1 cm{sup 2} skin area was estimated to be 13.2 mSv. The maximum measured dose rate values with a single TLD chip were between 7.5 and 25.1 mGy min{sup -1}. The effective dose corresponding to a proposed arsenic/selenium skin measurement was estimated to be 0.13 {mu}Sv for a 2 min irradiation.

  18. SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

    International Nuclear Information System (INIS)

    Olch, A

    2015-01-01

    Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Eleven neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has

  19. SU-E-T-616: Plan Quality Assessment of Both Treatment Planning System Dose and Measurement-Based 3D Reconstructed Dose in the Patient

    Energy Technology Data Exchange (ETDEWEB)

    Olch, A [University of Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Systematic radiotherapy plan quality assessment promotes quality improvement. Software tools can perform this analysis by applying site-specific structure dose metrics. The next step is to similarly evaluate the quality of the dose delivery. This study defines metrics for acceptable doses to targets and normal organs for a particular treatment site and scores each plan accordingly. The input can be the TPS or the measurement-based 3D patient dose. From this analysis, one can determine whether the delivered dose distribution to the patient receives a score which is comparable to the TPS plan score, otherwise replanning may be indicated. Methods: Eleven neuroblastoma patient plans were exported from Eclipse to the Quality Reports program. A scoring algorithm defined a score for each normal and target structure based on dose-volume parameters. Each plan was scored by this algorithm and the percentage of total possible points was obtained. Each plan also underwent IMRT QA measurements with a Mapcheck2 or ArcCheck. These measurements were input into the 3DVH program to compute the patient 3D dose distribution which was analyzed using the same scoring algorithm as the TPS plan. Results: The mean quality score for the TPS plans was 75.37% (std dev=14.15%) compared to 71.95% (std dev=13.45%) for the 3DVH dose distribution. For 3/11 plans, the 3DVH-based quality score was higher than the TPS score, by between 0.5 to 8.4 percentage points. Eight/11 plans scores decreased based on IMRT QA measurements by 1.2 to 18.6 points. Conclusion: Software was used to determine the degree to which the plan quality score differed between the TPS and measurement-based dose. Although the delivery score was generally in good agreement with the planned dose score, there were some that improved while there was one plan whose delivered dose quality was significantly less than planned. This methodology helps evaluate both planned and delivered dose quality. Sun Nuclear Corporation has

  20. Neutron dose rate at the SwissFEL injector test facility: first measurements

    International Nuclear Information System (INIS)

    Hohmann, E.; Frey, N.; Fuchs, A.; Harm, C.; Hoedlmoser, H.; Luescher, R.; Mayer, S.; Morath, O.; Philipp, R.; Rehmann, A.; Schietinger, T.

    2014-01-01

    At the Paul Scherrer Institute, the new SwissFEL Free Electron Laser facility is currently in the design phase. It is foreseen to accelerate electrons up to a maximum energy of 7 GeV with a pulsed time structure. An injector test facility is operated at a maximum energy of 300 MeV and serves as the principal test and demonstration plant for the SwissFEL project. Secondary radiation is created in unavoidable interactions of the primary beam with beamline components. The resulting ambient dose-equivalent rate due to neutrons was measured along the beamline with different commercially available survey instruments. The present study compares the readings of these neutron detectors (one of them is specifically designed for measurements in pulsed fields). The experiments were carried out in both, a normal and a diagnostic mode of operation of the injector. Measurements were taken at the SwissFEL injector test facility using three different types of commercially available survey instruments for normal and diagnostic mode of operation at different positions inside the accelerator vault. During normal operation, the doses indicated by the different instruments agree within the measurement uncertainty except for the beam dump region. There, due to its limited energy range and high sensitivity, the LB6411 shows significantly lower dose values than the other instruments. The photon background in the vault associated with each pulse causes the scintillator used by the LB6419 to saturate. As a result, only the channel using the delayed 12 C(n,p)12-reaction could be used during the measurements. The highest doses per pulse were measured next to the beam dump and the bunch compressor. For the optimisation of the accelerator, luminescent screens can be inserted into the beam path causing a dose distributed over several metres depending on the screen type. The dose arise to 40 % from neutrons with energies of >20 MeV. Although the charge of each pulse were reduced to decrease

  1. Radiation exposure of radiologists during angiography: Dose measurements outside the lead apron

    International Nuclear Information System (INIS)

    Fischer, H.; Przetak, C.; Teubert, G.; Ewen, K.; Moedder, U.

    1995-01-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r=0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons. (orig.) [de

  2. Dose-response relationships for chromosome aberrations in peripheral blood lymphocytes after whole- and partial-body irradiations. Pt. 1

    International Nuclear Information System (INIS)

    Liniecki, J.; Bajerska, A.; Wyszynska, K.

    1983-01-01

    Dose-response relationships were established for yield of dicentrics and for a fraction of damaged metaphases in lymphocytes after γ-irradiation of rabbits' whole blood in vitro. These relationships were based on the scoring of cells only in their first post-stimulation division and they served as a reference system for comparison with results of 60 Co γ-irradiation in vivo, either of the whole or of predetermined parts of an animal's body. There was a statistically acceptable agreement between dose-response data established for dicentric yield after whole-body irradiation in vivo and the reference dose-response curve derived from exposure of rabbit's blood in vitro. For partial-body (1/2) irradiations there was a satisfactory agreement between the dose-response curves in vitro for dicentric yield and fraction of metaphases damaged on the one hand and the response in vivo when the latter was related to mean doses to circulating blood. However, there was a drastic disagreement with the dose responses in vitro when measured cytogenetic quantities were plotted versus mean doses to body mass. When the latter were substituted for by comparable doses to circulating blood the in vivo-in vitro agreement was acceptable after irradiation. (orig.)

  3. Measurement of multi-slice computed tomography dose profile with the Dose Magnifying Glass and the MOSkin radiation dosimeter

    International Nuclear Information System (INIS)

    Lian, C.P.L.; Wong, J.H.D.; Young, A.; Cutajar, D.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2013-01-01

    This study describes the application of two in-house developed dosimeters, the Dose Magnifying Glass (DMG) and the MOSkin dosimeter at the Centre for Medical Radiation Physics, University of Wollongong, Australia, for the measurement of CT dose profiles for a clinical diagnostic 16-slice MSCT scanner. Two scanner modes were used; axial mode and helical mode, and the effect of varying beam collimation and pitch was studied. With an increase in beam collimation in axial mode and an increase of CT pitch in helical mode, cumulative point dose at scanner isocentre decreased while FWHM increased. There was generally good agreement to within 3% between the acquired dose profiles obtained by the DMG and the film except at dose profile tails, where film over-responded by up to 30% due to its intrinsic depth dose dependence at low doses. -- Highlights: ► This study shows the CT beam profiles acquired with our institution's detectors. ► The DMG is a relative dosimeter calibrated to absolute MOSkin readings. ► There was good agreement between dose profiles acquired by the DMG and the film

  4. Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs

    International Nuclear Information System (INIS)

    Rosskopf, Andrea B.; Pfirrmann, Christian W.A.; Buck, Florian M.

    2016-01-01

    To evaluate reliability of 2D and 3D lower limb measurements in adults using micro-dose compared to low-dose biplanar radiographs(BPR). One hundred patients (mean 54.9 years) were examined twice using micro-dose and low-dose BPR. Length and mechanical axis of lower limbs were measured on the antero-posterior(ap) micro-dose and low-dose images by two independent readers. Femoral and tibial torsions of 50 patients were measured by two independent readers using reconstructed 3D-models based on the micro-dose and low-dose BPR. Intermethod and interreader agreements were calculated using descriptive statistics, intraclass-correlation-coefficient(ICC), and Bland-Altman analysis. Mean interreader-differences on micro-dose were 0.3 cm(range 0-1.0)/ 0.7 (0-2.9) for limb length/axis and 0.4 cm (0-1.0)/0.8 (0-3.3) on low-dose BPR. Mean intermethod-difference was 0.04 cm ± 0.2/0.04 ± 0.6 for limb length/axis. Interreader-ICC for limb length/axis was 0.999/0.991 on micro-dose and 0.999/0.987 on low-dose BPR. Interreader-ICC for micro-dose was 0.879/0.826 for femoral/tibial torsion, for low-dose BPR was 0.924/0.909. Mean interreader-differences on micro-dose/low-dose BPR were 3 (0-13 )/2 (0 -12 ) for femoral and 4 (0-18 )/3 (0 -10 ) for tibial torsion. Mean intermethod-difference was -0.1 ± 5.0/-0.4 ± 2.9 for femoral/tibial torsion. Mean dose-area-product was significantly lower (9.9 times;p < 0.001) for micro-dose BPR. 2D-and 3D-measurements of lower limbs based on micro-dose BPR are reliable and provide a 10-times lower radiation dose. (orig.)

  5. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2001-06-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  6. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi

    2001-01-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  7. Mobilizing peripheral blood stem cells with high-dose G-CSF alone is as effective as with Dexa-BEAM plus G-CSF in lymphoma patients.

    Science.gov (United States)

    Kröger, N; Zeller, W; Fehse, N; Hassan, H T; Krüger, W; Gutensohn, K; Lölliger, C; Zander, A R

    1998-09-01

    We compared retrospectively the efficacy of granulocyte colony stimulating factor (G-CSF) alone with chemotherapy plus G-CSF in mobilizing CD34-positive cells in patients with malignant lymphoma. 35 patients underwent peripheral blood stem cell (PBSC) collection following mobilization either with 24 microg/kg G-CSF for 4 consecutive days (n = 18) or Dexa-BEAM chemotherapy plus 5 microg/kg G-CSF (n = 17). High-dose G-CSF was well tolerated with only slight bone pain and/or myalgia. The Dexa-BEAM therapy required hospitalization with a median duration of 21 d. The median number of apheresis procedures in both groups was two (range two to four), resulting in a median of 5.3 and 5.1 x 10(6) CD34+ cells/kg. No patients in the G-CSF group, but one in the Dexa-BEAM group, failed to reach the target of collecting >2.0 x 10(6) CD34+ cells/kg. The number of CFU-GM (10.4 v 6.0 x 10(5)/kg) and of BFU-E (10.6 v 4.5 x 10(5)/kg; P = 0.04) was higher in the G-CSF group than in the Dexa-BEAM group. A subset analysis of CD34+ cells was performed in 16 patients showing a higher mean of Thy-1 (CD90w) coexpression in the G-CSF than in the Dexa-BEAM group (4.8 v 1.8%, P = 0.12). Additionally the percentage of CD34+/CD38- cells was higher in the G-CSF group (10.66% v 8.8%). However, these differences were not statistically significant. The median time to leucocyte and platelet engraftment after high-dose chemotherapy was slightly shorter in the G-CSF than in the Dexa-BEAM group (9 v 10 and 12 v 13.5 d, respectively). These results demonstrate that high-dose G-CSF is as effective as Dexa-BEAM plus G-CSF in mobilizing peripheral blood stem cells and produces prompt engraftment. The major advantages of G-CSF mobilization were the safe outpatient self-application and the fixed-day apheresis.

  8. The uptake kinetics and immunotoxic effects of microcystin-LR in human and chicken peripheral blood lymphocytes in vitro

    International Nuclear Information System (INIS)

    Lankoff, Anna; Carmichael, Wayne W.; Grasman, Keith A.; Yuan, Moucun

    2004-01-01

    Microcystin-LR is a cyanobacterial heptapeptide that presents acute and chronic hazards to animal and human health. We investigated the influence of this toxin on human and chicken immune system modulation in vitro. Peripheral blood lymphocytes were treated with microcystin-LR at environmentally relevant doses of 1, 10 and 25 μg/ml for 12, 24, 48, 72 h (for proliferation assay cells were treated for 72 h). T-cell and B-cell proliferation as well as apoptosis and necrosis were determined in human and chicken samples. IL-2 and IL-6 production by human lymphocytes also was measured. In addition, uptake kinetics of microcystin-LR into human and chicken peripheral blood lymphocytes were calculated by Liquid Chromatography (LS) /Mass Spectrometry (MS) analysis. At the highest dose microcystin-LR decreased T-cell proliferation and all doses of microcystin-LR inhibited B-cell proliferation. The frequency of apoptotic and necrotic cells increased in a dose and time-dependent manner. Human lymphocytes responded to stimulation with microcystin-LR by increased production of IL-6 and decreased production of IL-2. Human lymphocytes were able to uptake from 0.014 to 1.663 μg/ml and chicken lymphocytes from 0.035 to 1.733 μg/ml of the microcystin-LR added to the cultures, depending on the treatment time and dose. In conclusion, microcystin-LR acted as an immunomodulator in cytokine production and down-regulated lymphocyte functions by induction of apoptosis and necrosis. However, further studies dealing with the influence of microcystin-LR on expression cytokine genes and transcription factors are necessary to confirm these hypotheses

  9. Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users.

    Science.gov (United States)

    Scheperle, Rachel A; Abbas, Paul J

    2015-01-01

    The ability to perceive speech is related to the listener's ability to differentiate among frequencies (i.e., spectral resolution). Cochlear implant (CI) users exhibit variable speech-perception and spectral-resolution abilities, which can be attributed in part to the extent of electrode interactions at the periphery (i.e., spatial selectivity). However, electrophysiological measures of peripheral spatial selectivity have not been found to correlate with speech perception. The purpose of this study was to evaluate auditory processing at the periphery and cortex using both simple and spectrally complex stimuli to better understand the stages of neural processing underlying speech perception. The hypotheses were that (1) by more completely characterizing peripheral excitation patterns than in previous studies, significant correlations with measures of spectral selectivity and speech perception would be observed, (2) adding information about processing at a level central to the auditory nerve would account for additional variability in speech perception, and (3) responses elicited with spectrally complex stimuli would be more strongly correlated with speech perception than responses elicited with spectrally simple stimuli. Eleven adult CI users participated. Three experimental processor programs (MAPs) were created to vary the likelihood of electrode interactions within each participant. For each MAP, a subset of 7 of 22 intracochlear electrodes was activated: adjacent (MAP 1), every other (MAP 2), or every third (MAP 3). Peripheral spatial selectivity was assessed using the electrically evoked compound action potential (ECAP) to obtain channel-interaction functions for all activated electrodes (13 functions total). Central processing was assessed by eliciting the auditory change complex with both spatial (electrode pairs) and spectral (rippled noise) stimulus changes. Speech-perception measures included vowel discrimination and the Bamford-Kowal-Bench Speech

  10. Review of techniques and detectors used in instruments for field measurement of beta doses and dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1983-01-01

    Generally, field measurements are required to assess the hazard from #betta#-rays before personnel are allowed to occupy a working space or perform a task. Occasionally, the measurements are required for an assessment after a #betta#-ray exposure is suspected to have occurred. Until recently the dose or dose rate have been the quantities of interest but there is now felt to be a need to characterize the energies and directions of the #betta#-rays as well. The purpose of #betta#-dosimetry is the assessment of hazard to superficial tissues (within approx. 10 mm of the surface) and that these tissues may also be exposed simultaneously to other ionizing radiations. The #betta#-dosimetry technique must take account of this. With these uses of field instruments in mind the following detectors, and associated techniques will be discussed in terms of the measurement principles, advantages and limitations: thin-walled ion chambers (sometimes in combination with thick-walled ones or with covers thick enough to prevent penetration of #betta#-particles); thin scintillators, nearly tissue equivalent, to provide a detector analogous to skin; scintillators, thick enough to absorb all the energy of the #betta#-particles (circuitry is required to count pulses according to size to permit calculation of dose or dose rate); silicon diodes with thin detection layers operated as photocurrent generators; silicon diodes, reversed biassed, with pulses counted according to size; and simple pulse counters (e.g., GM counters or silicon diodes with thin windows)

  11. Evaluation of the 'dose of the day' for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT

    International Nuclear Information System (INIS)

    Zijtveld, Mathilda van; Dirkx, Maarten; Breuers, Marcel; Kuipers, Ruud; Heijmen, Ben

    2010-01-01

    Purpose: High geometrical and dosimetrical accuracies are required for radiotherapy treatments where IMRT is applied in combination with narrow treatment margins in order to minimize dose delivery to normal tissues. As an overall check, we implemented a method for reconstruction of the actually delivered 3D dose distribution to the patient during a treatment fraction, i.e., the 'dose of the day'. In this article results on the clinical evaluation of this concept for a group of IMRT prostate cancer patients are presented. Materials and methods: The actual IMRT fluence maps delivered to a patient were derived from measured EPID-images acquired during treatment using a previously described iterative method. In addition, the patient geometry was obtained from in-room acquired cone-beam CT images. For dose calculation, a mapping of the Hounsfield Units from the planning CT was applied. With the fluence maps and the modified cone-beam CT the 'dose of the day' was calculated. The method was validated using phantom measurements and evaluated clinically for 10 prostate cancer patients in 4 or 5 fractions. Results: The phantom measurements showed that the delivered dose could be reconstructed within 3%/3 mm accuracy. For prostate cancer patients, the isocenter dose agreed within -0.4 ± 1.0% (1 SD) with the planned value, while for on average 98.1% of the pixels within the 50% isodose surface the actually delivered dose agreed within 3% or 3 mm with the planned dose. For most fractions, the dose coverage of the prostate volume was slightly deteriorated which was caused by small prostate rotations and small inaccuracies in fluence delivery. The dose that was delivered to the rectum remained within the constraints used during planning. However, for two patients a large degrading of the dose delivery was observed in two fractions. For one patient this was related to changes in rectum filling with respect to the planning CT and for the other to large intra-fraction motion during

  12. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Ehlerman, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    2001-03-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  13. Process control and dosimetry applied to establish a relation between reference dose measurements and actual dose distribution

    International Nuclear Information System (INIS)

    Ehlerman, D.A.E.

    2001-01-01

    The availability of the first commercial dose level indicator prompted attempts to verify radiation absorbed dose to items under quarantine control (e.g. for insect disinfestation) by some indicator attached to these items. Samples of the new commercial dose level indicators were tested for their metrological properties using gamma and electron irradiation. The devices are suitable for the intended purpose and the subjective judgement whether the threshold dose was surpassed is possible in a reliable manner. The subjective judgements are completely backed by the instrumental results. Consequently, a prototype reader was developed; first tests were successful. The value of dose level indicators and the implications of its use for food or quarantine inspection depends on a link between dose measured (indicated) at the position of such indicator and the characteristic parameters of the frequency distribution of dose throughout the product load i.e. a box or a container or a whole batch of multiple units. Therefore, studies into variability and statistical properties of dose distributions obtained under a range of commercial situations were undertaken. Gamma processing at a commercial multipurpose contract irradiator, electron processing and bremsstrahlung applications at a largescale research facility were included; products were apples, potatoes, wheat, maize, pistachio. Studies revealed that still more detailed information on irradiation geometries are needed in order to render meaningful information from dose label indicators. (author)

  14. Assessment of dose measurement uncertainty using RisøScan

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectiv......%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer. (c) 2006 Elsevier Ltd. All rights reserved....

  15. Measurement of neutron and gamma absorbed doses in phantoms exposed to mixed fields

    International Nuclear Information System (INIS)

    Beraud-Sudreau, E.; Lemaire, G.; Maas, J.

    1985-01-01

    In order to study the dosimetric characteristics of PIN junctions, the absorbed doses measured by junctions and FLi7 in air and water phantoms were compared with the doses measured by classical neutron dosimetry in mixed fields. The validity of the experimental responses of PIN junctions being thus checked and established, neutron and gamma dose distributions in tissue equivalent plastic phantoms (plastinaut) and mammals (piglets) were evaluated as well as the absorbed dose distributions in the pig bone-marrow producing areas. By using correlatively a Monte-Carlo calculation method and applying some simplifying assumptions, the absorbed doses were derived from the spectrum of SILENE's neutrons at various depths inside a cubic water phantom and the results were compared with some from the literature [fr

  16. Measurement and estimation of maximum skin dose to the patient for different interventional procedures

    International Nuclear Information System (INIS)

    Cheng Yuxi; Liu Lantao; Wei Kedao; Yu Peng; Yan Shulin; Li Tianchang

    2005-01-01

    Objective: To determine the dose distribution and maximum skin dose to the patient for four interventional procedures: coronary angiography (CA), hepatic angiography (HA), radiofrequency ablation (RF) and cerebral angiography (CAG), and to estimate the definitive effect of radiation on skin. Methods: Skin dose was measured using LiF: Mg, Cu, P TLD chips. A total of 9 measuring points were chosen on the back of the patient with two TLDs placed at each point, for CA, HA and RF interventional procedures, whereas two TLDs were placed on one point each at the postero-anterior (PA) and lateral side (LAT) respectively, during the CAG procedure. Results: The results revealed that the maximum skin dose to the patient was 1683.91 mGy for the HA procedure with a mean value of 607.29 mGy. The maximum skin dose at the PA point was 959.3 mGy for the CAG with a mean value of 418.79 mGy; While the maximum and the mean doses at the LAT point were 704 mGy and 191.52 mGy, respectively. For the RF procedure the maximum dose was 853.82 mGy and the mean was 219.67 mGy. For the CA procedure the maximum dose was 456.1 mGy and the mean was 227.63 mGy. Conclusion: All the measured dose values in this study are estimated ones which could not provide the accurate maximum value because it is difficult to measure using a great deal of TLDs. On the other hand, the small area of skin exposed to high dose could be missed as the distribution of the dose is successive. (authors)

  17. Environmental dose measurement with microprocessor based portable TLD reader

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.

    1996-01-01

    Application of TL method for environmental gamma-radiation dosimetry involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosemeter at the place of exposure ('in situ TLD reader') eliminates the above mentioned disadvantages. We have developed a microprocessor based portable TLD reader for monitoring environmental gamma-radiation doses and for on board reading out of doses on space stations. The first version of our portable, battery operated reader (named Pille - 'butterfly') was made at the beginning of the 80s. These devices used CaSO 4 bulb dosemeters and the evaluation technique was based on analogue timing circuits and analogue to digital conversion of the photomultiplier current with a read out precision of 1 μGy and a measuring range up to 10 Gy. The measured values were displayed and manually recorded. The version with an external power supply was used for space dosimetry as an onboard TLD reader

  18. Investigation of the influence of the working procedure on patient dose in angiography of the lower limbs

    International Nuclear Information System (INIS)

    Struelens, L.; Vanhavere, F.; Bosmans, H.

    2002-01-01

    This document presents dose measurements on patients in the field of interventional angiography. We have restricted this study to a common IR procedure, namely diagnostic angiography of the lower limbs. In this examination, radiographs are made over 6 adjoining standard regions from abdomen to feet. The RX tube is moved from one region to another under fluoroscopic guidance. To visualise the arteries, contrast media is injected through a catheter that has been inserted in the abdominal artery. The positioning of the catheter is also controlled by fluoroscopy. Only typical procedures (without medical complications) in male and female patients were considered in this study. Within the scope of the optimisation of patient doses, we looked for the influence of both the working procedure and the exposure parameters on patient dose. Examinations as performed by different operators and in different hospitals were included in the study. The effective dose E is calculated with the use of calculated derived conversion factors, which link practical dose measurements under well-defined conditions with estimates of the effective dose. Measurements in 4 different hospitals, 2 university hospitals and 2 peripheral hospitals are compared

  19. Activity measurement and effective dose modelling of natural radionuclides in building material

    International Nuclear Information System (INIS)

    Maringer, F.J.; Baumgartner, A.; Rechberger, F.; Seidel, C.; Stietka, M.

    2013-01-01

    In this paper the assessment of natural radionuclides' activity concentration in building materials, calibration requirements and related indoor exposure dose models is presented. Particular attention is turned to specific improvements in low-level gamma-ray spectrometry to determine the activity concentration of necessary natural radionuclides in building materials with adequate measurement uncertainties. Different approaches for the modelling of the effective dose indoor due to external radiation resulted from natural radionuclides in building material and results of actual building material assessments are shown. - Highlights: • Dose models for indoor radiation exposure due to natural radionuclides in building materials. • Strategies and methods in radionuclide metrology, activity measurement and dose modelling. • Selection of appropriate parameters in radiation protection standards for building materials. • Scientific-based limitations of indoor exposure due to natural radionuclides in building materials

  20. The use of polymer gel dosimetry to measure dose distribution around metallic implants

    International Nuclear Information System (INIS)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-01-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances. (author)

  1. [The use of polymer gel dosimetry to measure dose distribution around metallic implants].

    Science.gov (United States)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-10-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances.

  2. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  3. MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

    Energy Technology Data Exchange (ETDEWEB)

    Cervino, L; Soultan, D; Pettersson, N; Yock, A; Cornell, M; Aguilera, J; Murphy, J; Advani, S; Moiseenko, V [University of California, San Diego, La Jolla, CA (United States); Gill, B [British Columbia Cancer Agency, Vancouver, BC (Canada)

    2016-06-15

    Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240 cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.

  4. Measures associated with the dose limitation system at the TVO Power Company

    International Nuclear Information System (INIS)

    Ruuskanen, A.T.; Sundell, R.O.

    1982-01-01

    The paper discusses radiation protection practices at the TVO Power Company, which owns and operates two BWR units of Asea-Atom design at Olkiluoto, Finland. The installed electric power of each unit is 660MW. The full power operation of TVO I and TVO II began in 1979 and 1980, respectively. The dose limitation system calls for an organization which is responsible for radiation protection. This organization at the plant site is described. To limit doses a good knowledge of the work activities which cause doses is needed. There is a very up-to-date microprocessor-based work dosimetry system at the TVO power plant. The system provides a practicable means of measuring personal doses from various work activities. It also makes the allocation of radiation protection measures possible. The system and experience in applying it are discussed. The dose limitation system presupposes the realization of the optimization principle. The practice applied at TVO in order to limit internal contamination is presented. Owing to this practice, workers' internal doses have remained at a considerably low level. The paper discusses the ALARA values of different kinds of respiratory equipment. These values, which vary from 2x10 4 to 1x10 6 FIM/man.Sv (1 FIM=approx. US$ 0.22), can be used in the evaluation of different measures in avoiding internal doses. The operating policy of movable lead shields is presented. The ALARA value of this activity is evaluated to be about 5x10 4 FIM/man.Sv and on that basis it can be concluded that the use of movable lead shields is very efficient. The dose statistics for TVO's plant are presented. The doses have been less than 0.001 man.Sv/MW.a. Although the dose statistics for TVO are very good it is not realistic to consider solely the optimization aspect of radiation protection. The costs must also be kept in mind; these are presented in the paper. Problems in assessing the level of radiation protection practices on an annual basis are briefly discussed

  5. Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    Fadel, M A; El-Fiki, M A; Eissa, H M; Abdel-Hafez, A; Naguib, S H [National Institute of Standards, Cairo (Egypt)

    1996-03-01

    Phantom of tissue equivalent material with and without bone was used measuring depth dose distribution of gamma-rays from californium-252 source. The source was positioned at center of perspex walled phantom. Depth dose measurements were recorded for X, Y and Z planes at different distances from source. TLD 700 was used for measuring the dose distribution. Results indicate that implantation of bone in tissue equivalent medium cause changes in the gamma depth dose distribution which varies according to variation in bone geometry. 9 figs.

  6. A unique experiment. Measurement of radiation doses at Vinca

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1960-07-15

    For the first time in the history of the peaceful applications of atomic energy, an experiment was conducted to determine the exact levels of radiation exposure resulting from a reactor incident. The experiment was made at Vinca, Yugoslavia, wherein October 1958 six persons had been subjected to high doses of neutron and gamma radiation during a brief uncontrolled run of a zero-power reactor. One of them died but the other five were successfully treated at the Curie Hospital in Paris. In the case of four of them, the treatment involved the grafting of healthy bone marrow to counteract the effects of radiation on blood-forming tissues. It was recognized that if the effects produced on the irradiated persons could be related to the exact doses of radiation they had received, it would be possible to gain immensely valuable knowledge about the biological consequences of acute and high level radiation exposure on a quantitative basis. It was suggested to the Yugoslav authorities that a dosimetry experiment be conducted at Vinca. The most accurate modern techniques of dosimetry developed at the Oak Ridge National Laboratory were employed during the experiment. Simultaneous measurements of the neutron and gamma doses were made at points where the people had been located. At these points the effects of the radiation on the salt solution in the phantoms were studied. In particular, the energy distribution of the radiation was investigated.It was the ratio between the various components of the radiation that was of special interest in these measurements because this ratio itself would help in determining the exact doses. The dose of one of the components, viz. slow neutrons, had already been determined during the treatment of the patients. If the ratio of the components could be ascertained, the doses of the fast neutrons and gamma rays could also be established because the ratio would not be affected by the power level at which the reactor was operated

  7. Peripheral collisions in Ar induced reactions between 27 and 44 A.MeV: study of energy dissipation by measuring the correlated neutron multiplicities

    International Nuclear Information System (INIS)

    Guerreau, D.; Doubre, H.; Galin, J.; Pouthas, J.; Jahnke, U.; Jiang, D.X.; Lott, B.; Jacquet, D.

    1988-01-01

    A 4 π detector measuring the neutron multiplicities has been used to investigate the energy dissipation during peripheral collisions in Ar induced reactions around the Fermi Energy. Besides the persistance of direct transfer reactions for the most peripheral collisions, there are strong evidences for the occurrence of quite large energy dissipation, a clear signature for the one body friction to still play a major role at these intermediate energies

  8. Occupational exposure of phosphate mine workers: airborne radioactivity measurements and dose assessment

    International Nuclear Information System (INIS)

    Khater, Ashraf E.; Hussein, M.A.; Hussein, Mohamed I.

    2004-01-01

    Under the Egyptian program for radiation safety and control, airborne radioactivity measurements and radiological dose assessment were conducted in some phosphate and uranium mines. Abu-Tartor mine is one of the biggest underground phosphate mines in Egypt. Airborne radioactivity, radon ( 222 Rn) and its short-lived decay products (progenies) and thoron ( 220 Rn), were measured in selected locations along the mine. The environmental gamma and workers dose equivalent rate (mSv/y) were measured inside and outside the mine using thermo-luminescence dosimeters (TLD). The results were presented and discussed. The calculated annual effective dose due to airborne radioactivity is the main source of occupational exposure and exceeding the maximum recommended level by ICRP-60 inside the mine tunnels. A number of recommendations are suggested to control the occupational exposures

  9. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  10. MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Flores-Martinez, E; Malin, M; DeWerd, L [University of WI-Madison/ADCL, Madison, WI (United States)

    2015-06-15

    Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

  11. Phase space determination from measured dose data for intraoperative electron radiation therapy.

    Science.gov (United States)

    Herranz, E; Herraiz, J L; Ibáñez, P; Pérez-Liva, M; Puebla, R; Cal-González, J; Guerra, P; Rodríguez, R; Illana, C; Udías, J M

    2015-01-07

    A procedure to characterize beams of a medical linear accelerator for their use in Monte Carlo (MC) dose calculations for intraoperative electron radiation therapy (IOERT) is presented. The procedure relies on dose measurements in homogeneous media as input, avoiding the need for detailed simulations of the accelerator head. An iterative algorithm (EM-ML) has been employed to extract the relevant details of the phase space (PHSP) of the particles coming from the accelerator, such as energy spectra, spatial distribution and angle of emission of particles. The algorithm can use pre-computed dose volumes in water and/or air, so that the machine-specific tuning with actual data can be performed in a few minutes. To test the procedure, MC simulations of a linear accelerator with typical IOERT applicators and energies, have been performed and taken as reference. A solution PHSP derived from the dose produced by the simulated accelerator has been compared to the reference PHSP. Further, dose delivered by the simulated accelerator for setups not included in the fit of the PHSP were compared to the ones derived from the solution PHSP. The results show that it is possible to derive from dose measurements PHSP accurate for IOERT MC dose estimations.

  12. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter

    International Nuclear Information System (INIS)

    Salehhon, N; Hashim, S; Karim, M K A; Ang, W C; Musa, Y; Bahruddin, N A

    2017-01-01

    The increasing use of computed tomography (CT) in clinical practice marks the needs to understand the dose descriptor and dose profile. The purposes of the current study were to determine the CT dose index free-in-air (CTDI air ) in 128 slice CT scanner and to evaluate the single scan dose profile (SSDP). Thermoluminescent dosimeters (TLD-100) were used to measure the dose profile of the scanner. There were three sets of CT protocols where the tube potential (kV) setting was manipulated for each protocol while the rest of parameters were kept constant. These protocols were based from routine CT abdominal examinations for male adult abdomen. It was found that the increase of kV settings made the values of CTDI air increased as well. When the kV setting was changed from 80 kV to 120 kV and from 120 kV to 140 kV, the CTDI air values were increased as much as 147.9% and 53.9% respectively. The highest kV setting (140 kV) led to the highest CTDI air value (13.585 mGy). The p -value of less than 0.05 indicated that the results were statistically different. The SSDP showed that when the kV settings were varied, the peak sharpness and height of Gaussian function profiles were affected. The full width at half maximum (FWHM) of dose profiles for all protocols were coincided with the nominal beam width set for the measurements. The findings of the study revealed much information on the characterization and performance of 128 slice CT scanner. (paper)

  13. Measurement of depth-dose distributions by means of the LiF-fluoroplastic thermoluminescent detectors

    International Nuclear Information System (INIS)

    Shaks, A.I.; Uryaev, I.A.; Trifonov, V.A.; Reshetnikova, L.V.

    1977-01-01

    Depth-dose distributions have been studied by means of thin-layer thermoluminescent detectors LiF-fluoroplast (8 mg/cm 2 ). Dosimetric characteristics of the detectors are described. They are: tissue-equivalence, dependence of sensitivity on the dose, dose rate and angle of incidence of radiation, and time-dependent storage, of the total light absorbed. Comparison of the results obtained with the measurements taken with an extrapolation chamber has demonstrated the possibility of measuring the depth-dose distributions by means of LiF-fluoroplast detectors

  14. SU-E-T-481: In Vivo and Post Mortem Animal Irradiation: Measured Vs. Calculated Doses

    Energy Technology Data Exchange (ETDEWEB)

    Heintz, P [Univ New Mexico Radiology Dept., Albuquerque, NM (United States); Heintz, B [Texas Oncology, PA, Southlake, TX (United States); Sandoval, D [University of New Mexico, Albuquerque, NM (United States); Weber, W; Melo, D; Guilmette, R [Lovelace Respiratory Research Institute, Albuquerque, NM (United States)

    2015-06-15

    Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. The subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.

  15. Accredited dose measurements for validation of radiation sterilized products

    DEFF Research Database (Denmark)

    Miller, A.

    1993-01-01

    for control of radiation sterilization. The accredited services include: 1. 1. Irradiation of dosimeters and test samples with cobalt-60 gamma rays. 2. 2. Irradiation of dosimeters and test samples with 10 MeV electrons. 3. 3. Issue of and measurement with calibrated dosimeters. 4. 4. Measurement...... of the dosimetric parameters of an irradiation facility. 5. 5. Measurement of absorbed dose distribution in irradiated products. The paper describes these services and the procedures necessary for their execution....

  16. SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States); Chu, A [Yale New Haven Hospital, New Haven, CT (United States); Chi, Y [Winter Park Cancer Center, Winter Park, FL (United States); Hu, J [Wayne State University, Detroit, MI (United States)

    2014-06-15

    Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

  17. The effects of increasing doses of MK-467, a peripheral alpha(2)-adrenergic receptor antagonist, on the cardiopulmonary effects of intravenous dexmedetomidine in conscious dogs.

    Science.gov (United States)

    Honkavaara, J M; Restitutti, F; Raekallio, M R; Kuusela, E K; Vainio, O M

    2011-08-01

    Different doses of MK-467, a peripheral alpha(2)-adrenergic receptor antagonist, with or without dexmedetomidine were compared in conscious dogs. Eight animals received either dexmedetomidine (10 μg/kg [D]), MK-467 (250 μg/kg [M250] or dexmedetomidine (10 μg/kg) with increasing doses of MK-467 (250 μg/kg [DM250], 500 μg/kg [DM500] and 750 μg/kg [DM750], respectively). Treatments were given intravenously (i.v.) in a randomized, crossover design with a 14-day washout period. Systemic hemodynamics and arterial blood gas analyses were recorded at baseline and at intervals up to 90 min after drugs administration. Dexmedetomidine alone decreased heart rate, cardiac index and tissue oxygen delivery and increased mean arterial pressure and systemic vascular resistance 5 min after administration. DM250 did not completely prevent these early effects, while DM750 induced a decrease in mean arterial pressure. With DM500, systemic hemodynamics remained stable throughout the observational period. MK-467 alone increased cardiac index and tissue oxygen delivery and had no deleterious adverse effects. No differences in arterial blood gases were observed between treatments that included dexmedetomidine. It was concluded that MK-467 attenuated or prevented dexmedetomidine's systemic hemodynamic effects in a dose-dependent manner when given simultaneously i.v. but had no effect on the pulmonary outcome in conscious dogs. A 50:1 dose ratio (MK-467:dexmedetomidine) induced the least alterations in cardiovascular function. © 2010 Blackwell Publishing Ltd.

  18. Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project

    International Nuclear Information System (INIS)

    Vanhavere, F.; Carinou, E.; Domienik, J.; Donadille, L.; Ginjaume, M.; Gualdrini, G.; Koukorava, C.; Krim, S.; Nikodemova, D.; Ruiz-Lopez, N.; Sans-Merce, M.; Struelens, L.

    2011-01-01

    Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe ( (www.oramed-fp7.eu)). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoring of the eye lens should be performed on routine basis.

  19. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    Energy Technology Data Exchange (ETDEWEB)

    Almen, A J

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs.

  20. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    International Nuclear Information System (INIS)

    Almen, A.J.

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs

  1. Spherical ionization chamber of 14 liter for precise measurement of environmental radiation dose rate

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Saito, Kimiaki; Moriuchi, Shigeru

    1991-05-01

    A spherical ionization chamber of 14 liter filled with 1 atm. nitrogen gas was arranged aiming at precise measurement of dose rate due to environmental gamma rays and cosmic rays. Ionization current-dose rate conversion factor for this ionization chamber was derived from careful consideration taking into account the attenuation by chamber wall, ionization current due to alpha particles and so on. Experiments at calibrated gamma ray fields and intercomparison with NaI(Tl) scintillation detector were also performed, which confirmed this ionization chamber using the conversion factor can measure the dose rate with an error of only a few percent. This ionization chamber will be used for measurement of environmental gamma ray and cosmic ray dose rate. (author)

  2. Metformin attenuates olanzapine-induced hepatic, but not peripheral insulin resistance.

    Science.gov (United States)

    Remington, Gary J; Teo, Celine; Wilson, Virginia; Chintoh, Araba; Guenette, Melanie; Ahsan, Zohra; Giacca, Adria; Hahn, Margaret K

    2015-11-01

    Antipsychotics (APs) are linked to diabetes, even without weight gain. Whether anti-diabetic drugs are efficacious in reversing the direct effects of APs on glucose pathways is largely undetermined. We tested two metformin (Met) doses to prevent impairments seen following a dose of olanzapine (Ola) (3 mg/kg); glucokinetics were measured using the hyperinsulinemic-euglycemic clamp (HIEC). Met (150 mg/kg; n=13, or 400 mg/kg; n=11) or vehicle (Veh) (n=11) was administered through gavage preceding an overnight fast, followed by a second dose prior to the HIEC. Eleven additional animals were gavaged with Veh and received a Veh injection during the HIEC (Veh/Veh); all others received Ola. Basal glucose was similar across treatment groups. The Met 400 group had significantly greater glucose appearance (Ra) in the basal period (i.e., before Ola, or hyperinsulinemia) vs other groups. During hyperinsulinemia, glucose infusion rate (GINF) to maintain euglycemia (reflective of whole-body insulin sensitivity) was higher in Veh/Veh vs other groups. Met 150/Ola animals demonstrated increased GINF relative to Veh/Ola during early time points of the HIEC. Glucose utilization during hyperinsulinemia, relative to basal conditions, was significantly higher in Veh/Veh vs other groups. The change in hepatic glucose production (HGP) from basal to hyperinsulinemia demonstrated significantly greater decreases in Veh/Veh and Met 150/Ola groups vs Veh/Ola. Given the increase in basal Ra with Met 400, we measured serum lactate (substrate for HGP), finding increased levels in Met 400 vs Veh and Met 150. In conclusion, Met attenuates hepatic insulin resistance observed with acute Ola administration, but fails to improve peripheral insulin resistance. Use of supra-therapeutic doses of Met may mask metabolic benefits by increasing lactate. © 2015 Society for Endocrinology.

  3. Dual-peak dose measurement for radiochromic films by a newly developed spectral microdensitometer

    International Nuclear Information System (INIS)

    Lee, K.Y.; Fung, K.K.L.; Kwok, C.S.

    2005-01-01

    Radiochromic film (RCF) dosimetry is usually based on densitometric methods which use an analyzing light source of a fixed or a broad spectrum of wavelengths. These methods have not exploited the sensitivity of the dose response of the RCF otherwise attainable by using a light source with wavelengths peaked at the two absorption peaks in the absorption spectrum of the RCF. A new algorithm of dual-peak dose measurement for the RCF has been proposed in this paper to make use of these dual absorption peaks to achieve the maximum attainable sensitivity. This technique relies on the measurement of the transmittance of the RCF at the wavelength of the major and minor absorption peaks, respectively. The dual-peak dose measurement is accomplished with the aid of a novel spectral microdensitometer developed in our Institute. The microdensitometer utilizes a monochromator to provide a light source of which the wavelength can be matched precisely to the wavelength of the absorption peaks of the RCF. The doses obtained at these wavelengths are fed into a weighted objective function and an optimum dose is searched by minimizing the objective function to give the best estimate of the dose deposited on the film. An initial test shows that there is a good agreement between the estimated and actual dose deposited; and the maximum discrepancy was found to be less than 1%

  4. Tailored Rabbit Antithymocyte Globulin Induction Dosing for Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Namita Singh, MD

    2018-02-01

    Conclusions. The novel findings of the current study include peripheral administration, reduced dosing, favorable safety, excellent allograft outcomes, and clear associative data regarding reduced costs and length of stay.

  5. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  6. HPRT gene locus mutation in peripheral blood lymphocytes induced by internal exposure to radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Jingyong, Zhao; Yongzhong, Xu; Tao, Zhao; Fengmei, Cui; Liuyi, Wang; Qinhua, Lao [Suzhou Univ., Suzhou (China). Radiation Medicine Department

    2001-07-01

    HPRT gene locus mutation in peripheral blood lymphocytes induced by internal exposure to radionuclides was performed and the relationships between mutation frequency and dose were studied. Rats were injected intravenously with radionuclides, the blood was sampled at different time after injection; HPRT gene locus mutation frequency (GMF) were examined by methods of multi-nucleus cell and Brdurd assay, working out the Dose-response function. GMF rose with the increase of dose and dose-rates and were clearly interrelated. The HPRT gene locus mutation is very sensitive to radiation and may be used as a biological dosimeter.

  7. Measurement of Skin Dose from Using the Treatment Immobilization Devices

    International Nuclear Information System (INIS)

    Je, Jae Yong; Park, Chul Woo; Noh, Kyung Suk

    2009-01-01

    The research was about the relation between the dorsal side dose measured by using the phantom body (Alderson Rando Phantom) and factors like contacted material of the patients, the size of the field, angle of incidence. Compared with mylar (tennis racket), the dose on 10 x 10 cm 2 field size of cotton was increased by 2% and by 8% in the case of breast board. In the case of 15 x 15 cm 2 field size, the dose was increased by 6% compared with 10 x 10 cm 2 size. The field size of 20 x 20 cm 2 resulted in 10% increase of dose, while 5 x 5 cm 2 produced 13% decrease. Compared with incident angle 0 degree, the cases for the incident angle 5 degrees had 0.4% less dose for breast board, 0.5% for tennis racket, 1.1% for cotton. The cases for the incident angle 10 degrees had 1.5% less dose for breast board, 1.9% for tennis racket, 2.6% for cotton. For the incident angle 15 degrees, breast board, tennis racket, cotton caused decrease of dose by 3.9%, 2.6%, 3.86% respectively. Resultantly carbon material can cause more skin dose in treatment field. By the results of this study, we recommend that one should avoid the contact between the carbon material and skin.

  8. Measurement of beta emitting radionuclides in dose calibrators routinely used in nuclear medicine departments

    International Nuclear Information System (INIS)

    Tastan, S.; Soylu, A.; Kucuk, O.; Ibis, E.

    2004-01-01

    Full text: Radionuclides for diagnostics purposes like Tc-99m, Tl-201, Ga-67 and In-111 are measured by using ionization type of dose calibrators. Therapeutic radionuclides, which emit both beta and gamma rays are detected by the same type of dose calibrators. Other therapeutic products like Y-90, P-32 and Sr-89 are pure beta emitters and they are gaining wider utility because various new therapy radiopharmaceuticals are being developed. The type of container material, like glass or plastic, may seriously affect radioactivity measurement due to attenuation, Since it is crucial to give the exact amount of radioactivity to the patient for therapy purposes, dedicated dose calibrators are specially manufactured for the measurement of these radionuclides. But these measuring systems are not widely available in nuclear medicine centers where therapy is applied to the patient. It is a known fact that dose calibrators routinely used in nuclear medicine departments can be calibrated for vials and syringes using standard sources of the same radioisotope. The method of calibration of Y-90 measurement for two ionization chamber dose calibrators available in the institute will be summarized in this presentation

  9. Measurement of beta emitting radionuclides in dose calibrators routinely used in nuclear medicine departments

    International Nuclear Information System (INIS)

    Tastan, S.; Soylu, A.; Kucuk, O.; Ibis, E.

    2004-01-01

    Radionuclides for diagnostics purposes like Tc-99m, Tl-201, Ga-67 and In-111 are measured by using ionization type of dose calibrators. Therapeutic radionuclides, which emit both beta and gamma rays are detected by the same type of dose calibrators. Other therapeutic products like Y-90, P-32 and Sr-89 are pure beta emitters and they are gaining wider utility because various new therapy radiopharmaceuticals are being developed. The type of container material, like glass or plastic, may seriously affect radioactivity measurement due to attenuation, Since it is crucial to give the exact amount of radioactivity to the patient for therapy purposes, dedicated dose calibrators are specially manufactured for the measurement of these radionuclides. But these measuring systems are not widely available in nuclear medicine centers where therapy is applied to the patient. It is a known fact that dose calibrators routinely used in nuclear medicine departments can be calibrated for vials and syringes using standard sources of the same radioisotope. The method of calibration of Y-90 measurement for two ionization chamber dose calibrators available in the institute will be summarized in this presentation. (author)

  10. Cytogenetic measurements of the relative biological effectiveness of tritium

    International Nuclear Information System (INIS)

    Chopra, C.; Heddle, J.A.

    1988-10-01

    Chromosome aberrations in peripheral blood lymphocytes, which are used to estimate radiation dose biologically, were induced by tritium 1.14 times as effectively as X-rays (95% confidence limits: 0.8 - 1.5). Chromosome translocations in spermatogonia, which are one component of genetic risk, were induced by tritium 1.21 times as effectively as X-rays (95% confidence limits: 0.8 -1.9). All experimental measurements were made in CBA/H mice injected with tritiated water or exposed to X-rays at a comparable dose rate

  11. Dose measurement techniques for high-energy photon and electron radiation

    International Nuclear Information System (INIS)

    Hohlfeld, K.; Roos, M.

    1992-08-01

    By law the Federal Institute of Physics and Technology (PTB) has been assigned the tasks of representing, preserving and passing on dose units. The analogous continuation of these tasks consists in improving, at the user level, dosimetry techniques in radiation therapy for the benefit of patients. The PTB had an essential share in working out the scientific foundations of dosimetry for high-energy radiation, and the corresponding DIN standards were established with the PTB playing a prominent part. The seminar aimed at presenting the measuring techniques fixed in the new DIN standard 6800 part 2 'Dose measurement techniques according to the probe method - ionization dosimetry', to discuss their physical background and practical implications resulting from them. (orig.) [de

  12. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  13. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    OpenAIRE

    O. G. Pozdeyeva; T. B. Shaimov; A. Yu. Galin; R. B. Shaimov; T. A. Shaimova; A. V. Zolotova; A. V. Fomin

    2014-01-01

    Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes) with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of op...

  14. Measurements of the electron dose distribution near inhomogeneities using a plastic scintillation detector

    International Nuclear Information System (INIS)

    Wells, C.M.M.; Mackie, T.R.; Podgorsak, M.B.; Holmes, M.A.; Papanikolaou, N.; Reckwerdt, P.J.; Cygler, J.; Rogers, D.W.O.; Bielajew, A.F.; Schmidt, D.G.

    1994-01-01

    Accurate measurement of the electron dose distribution near an inhomogeneity is difficult with traditional dosimeters which themselves perturb the electron field. The authors tested the performance of a new high resolution, water-equivalent plastic scintillation detector which has ideal properties for this application. A plastic scintillation detector with a 1 mm diameter, 3 mm long cylindrical sensitive volume was used to measure the dose distributions behind standard benchmark inhomogeneities in water phantoms. The plastic scintillator material is more water equivalent than polystyrene in terms of its mass collision stopping power and mass scattering power. Measurements were performed for beams of electrons having initial energies of 6 and 18 MeV at depths from 0.2-4.2 cm behind the inhomogeneities. The detector reveals hot and cold spots behind heterogeneities at resolutions equivalent to typical film digitizer spot sizes. Plots of the dose distributions behind air, aluminum, lead, and formulations for cortical and inner bone-equivalent materials are presented. The plastic scintillation detector is suited for measuring the electron dose distribution near an inhomogeneity. 14 refs., 9 figs

  15. Comparison of two techniques for natural dose measurements

    International Nuclear Information System (INIS)

    Ekdal, E.; Ege, A.; Goekce, M.; Karali, T.; Derin, Z.

    2006-01-01

    In the study of luminescence dating, age of an archaeological sample is calculated by the ratio of total exposed dose to annual dose resulted from the environmental radioactivity. Determination of the annual dose level of an archaeological area is one of the most important parameter in calculating the archaeological age of the sample using luminescence techniques. Therefore, the knowledge of the concentrations of the natural radionuclides is important since naturally occurring radioactivity provides major contribution to the annual dose. The natural radioactivity is originated from natural radionuclides consisting mainly of 2 38U, 2 32Th and 4 0K isotopes together with their daughters in soils. In this study, annual dose level of the archaeological site was determined with two different methods: an indirect method that is determining the concentrations of the naturally occurring radioactive elements using gamma spectroscopy and a direct method that uses thermoluminescence dosimeters. Soil samples were collected from the Yesilova Hoeyuek archaeological site located in Izmir City at the Aegean Region of Turkey. The concentrations of the natural radioactivity ( 2 38U, 2 32Th and 4 0K) in soil samples were determined using 3 x 3 N aI (Tl) γ-ray spectrometry system. In direct method, Al 2 O 3 :C thermoluminescence dosimeters (TLD's) were used. These dosimeters were chosen because of their sensitivity and usability in dating studies. They were buried in same archaeological site, 30 cm depth from the soil surface for 30 days period. The luminescence intensity of Al 2 O 3 :C dosimeters was measured by a TLD reader and the dose level was calculated by the luminescence signals emitted by the dosimeters. The results obtained from natural radionuclides and Al 2 O 3 :C thermoluminescence dosimeters were compared and the source of the differences between two methods were discussed

  16. Variation in the biochemical response to l-thyroxine therapy and relationship with peripheral thyroid hormone conversion efficiency

    Science.gov (United States)

    Midgley, John E M; Larisch, Rolf; Dietrich, Johannes W; Hoermann, Rudolf

    2015-01-01

    Several influences modulate biochemical responses to a weight-adjusted levothyroxine (l-T4) replacement dose. We conducted a secondary analysis of the relationship of l-T4 dose to TSH and free T3 (FT3), using a prospective observational study examining the interacting equilibria between thyroid parameters. We studied 353 patients on steady-state l-T4 replacement for autoimmune thyroiditis or after surgery for malignant or benign thyroid disease. Peripheral deiodinase activity was calculated as a measure of T4–T3 conversion efficiency. In euthyroid subjects, the median l-T4 dose was 1.3 μg/kg per day (interquartile range (IQR) 0.94,1.60). The dose was independently associated with gender, age, aetiology and deiodinase activity (all P29 nmol/s revealed an increasing FT3–FT4 dissociation; the poorest converters showed the lowest FT3 levels in spite of the highest dose and circulating FT4 (P<0.001). An l-T4-related FT3–TSH disjoint was also apparent; some patients with fully suppressed TSH failed to raise FT3 above the median level. These findings imply that thyroid hormone conversion efficiency is an important modulator of the biochemical response to l-T4; FT3 measurement may be an additional treatment target; and l-T4 dose escalation may have limited success to raise FT3 appropriately in some cases. PMID:26335522

  17. Radiation dose measurement for patients and staff during cardiac catheterization

    International Nuclear Information System (INIS)

    Joda, H. H. M.

    2009-07-01

    The primary objective of this study was to determine the patient and staff dose during cardiac catheterization procedures in Ahmed Gasim Hospital, Khartoum Bahry. A survey of patient and staff exposure was performed covered 2 Cath Lab units from 2 manufacturers. The measurements involved 50 operations. The medical staff was monitored using TLD chips (LiF: Mg, Cu, P). The main operator who was closer to the patient and the x-ray tube, was monitored at six positions (forehead, neck chest - over the lead apron, waist - under the lead apron, leg, and hand), while the exposure to the assistant was measured at two positions (chest - over the lead apron, and hand), where the technologist and the circulator were monitored at one position (chest - over the lead apron). patient exposure was measured using the DAP meter. The main operator and the rest of the staff received 0.14, 0.01 mSv/y respectively. The estimated patient dose rate was found to be 125 mGy/min which considered higher than the recommended DRL for the continuous high mode fluoroscopy used in interventional radiology (100 mGy/min). The study concluded to the fact that the main operator received relatively high dose which is a direct result to the poor radiation protection in the department. (Author)

  18. Effect of heterogeneity of human population in cell radiosensitivity on the extrapolation of dose-response relationships to low doses

    International Nuclear Information System (INIS)

    Filyushkin, I.V.; Bragin, Yu.N.; Khandogina, E.K.

    1989-01-01

    Presented are the results of an investigation of the dose-response relationship for the yield of chromosome aberrations in peripheral blood lymphocytes of persons with some hereditary diseases which represent the high risk group with respect to the increased incidence of malignant tumors and decreased life span. Despite substantially different absolute radiosensitivities of chromosomes, the variations of the alpha/beta ratio determining the extrapolation of experimental dose-response relationships to low doses did not prove to be too high, the mean deviation from the control being 15%. This points to the possible practical use of the dose-response relationships averaged over the human population as a whole

  19. Cytogenetics dosimetry: dose-response curve for low doses of X-ray; Dosimetria citogenetica: curva dosis-respuesta para bajas dosis de rayos-X

    Energy Technology Data Exchange (ETDEWEB)

    Lara, Virginia E. Noval; Pineda Bolivar, William R.; Riano, Victor M. Pabon, E-mail: venovall.15@hotmail.com, E-mail: wrpineda@misena.edu.co, E-mail: vmpabonr@udistrital.edu.co [Universidad Distrital Francisco Jose de Caldas (UD), Bogota (Colombia). Grupo de Investigacion en Ciencia y Tecnologia Nuclear; Ureana, Cecilia Crane, E-mail: cecicrane@yahoo.com [Instituto Nacional de Salud (INS), Bogota (Colombia). Laboratorio de Genetica

    2013-07-01

    The purpose of this study was to conduct a preliminary study for the standardization in the future, the dose-response curve for low doses of X-rays, through the analysis of in vitro cultures of peripheral blood samples of 3 men and 3 women occupationally not exposed to artificial sources of ionizing radiation, age 18-40 years, where possible nonsmokers.

  20. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.